{"product_id":"abb-ac-800m-3bse082896r1-pm858k02-cpu-module","title":"ABB AC 800M 3BSE082896R1 PM858K02 CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe ABB PM858K02 \u003cspan\u003e3BSE082896R1\u003c\/span\u003e is a high-reliability Redundant Controller Kit configured for the \u003cstrong\u003eAC 800M\u003c\/strong\u003e control platform. This processing assembly includes \u003cstrong\u003edual redundant CPU modules\u003c\/strong\u003e paired with redundant power connection paths to eliminate single points of failure in mission-critical process loops. Operating on a \u003cstrong\u003e33 MHz MPC866 processor\u003c\/strong\u003e architecture with \u003cstrong\u003e16 MB of integrated RAM\u003c\/strong\u003e, the unit executes complex logic, regulatory loops, and advanced communication sequences with a deterministic benchmark of 0.36 ms per 1000 Boolean operations. Designed specifically for integration with System 800xA and Compact Control Builder, the module features a ruggedized hardware footprint with an \u003cstrong\u003eIP20 protection rating\u003c\/strong\u003e and \u003cstrong\u003eISA Secure certification\u003c\/strong\u003e, ensuring both physical endurance and strict cybersecurity conformity across severe industrial processing environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Module Redundancy:\u003c\/strong\u003e Packaged as a complete redundant controller kit (PM858K02) utilizing primary and secondary processor sync states to prevent unexpected system downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSub-Millisecond Logic Execution:\u003c\/strong\u003e Delivers deterministic 0.36 ms processing performance for every 1000 Boolean control commands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISA Secure Compliance:\u003c\/strong\u003e Validated under strict industrial cybersecurity baselines to safeguard control networks from unauthorized access and external protocol exploits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial G3 Conformal Coating:\u003c\/strong\u003e Complies fully with ISA 71.04 G3 corrosion mitigation parameters, facilitating sustained deployment in corrosive chemical or humid atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModularity and Expandability:\u003c\/strong\u003e Supports direct interfacing with up to 256 physical I\/O modules and accommodates multiple CEX-Bus communication interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous process control in petrochemical and chemical refining facilities.\u003c\/li\u003e\n\u003cli\u003eTurbine, boiler, and balance-of-plant automation in thermal power generation stations.\u003c\/li\u003e\n\u003cli\u003eComplex multi-node distributed network topologies within water and wastewater treatment works.\u003c\/li\u003e\n\u003cli\u003eCritical safety interlocking and sequence operations across pulp, paper, and heavy mineral processing plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n\u003cth style=\"padding: 10px; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eArticle Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e\n\u003cspan\u003e3BSE082896R1\u003c\/span\u003e (Kit Model: PM858K02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eControl Platform Series\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eAC 800M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eMPC866 (33 MHz Clock Frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eSystem Memory\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e16 MB RAM (7.147 MB application execution overhead)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eYes (Dual Redundant Module Configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eBoolean Performance Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e0.36 ms per 1000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eIntegrated Interfaces\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e2 x RJ45 Ethernet Ports, 1 x RS-232C, 1 x Isolated RS-232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eProtocol Support Options\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eModbus TCP\/IP, EtherNet\/IP, PROFIBUS DP (via CEX-Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eIngress Protection Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eIP20 (IEC 60529 \/ EN 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e+5 to +55 Celsius (+41 to +131 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e-40 to +70 Celsius (-40 to +158 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eRelative Humidity Limits\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eCorrosion Compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eG3 Compliant according to ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eSoftware Compatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eSystem 800xA 6.0.2 \/ Compact Control Builder 6.0.0-1 or newer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eElectrical Safety Standards\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eEN 50178, IEC 61131-2, UL 61010-1, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eHazardous Certifications\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003ecULus Class 1, Zone 2, AEx nA IIC T4, ExnA IIC T4Gc X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eMarine Certificates\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eDNV-GL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003ePhysical Dimensions (Single Unit)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e119 mm x 186 mm x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e245 mm x 310 mm x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2d3748;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e2.65 kg (Dual-module components and baseplates included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin: 20px 0;\"\u003e\n\u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL WARNING: LIVE EQUIPMENT HAZARD\u003c\/strong\u003e \u003cspan style=\"color: #9b2c2c;\"\u003eIsolate all 24V DC field power loops and main network connections supplying the local TP830 baseplate or CEX-Bus segments before handling components. Inserting or removing processing modules while the backplane is energized can cause catastrophic electrical arcing, micro-controller data corruption, and immediate hardware damage. Ensure proper electrostatic discharge (ESD) ground straps are utilized throughout handling.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 20px 0;\"\u003e\n\u003cdiv style=\"margin-bottom: 15px; position: relative; padding-left: 40px;\"\u003e\n\u003cdiv style=\"position: absolute; left: 0; top: 0; width: 28px; height: 28px; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; text-align: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n\u003cspan style=\"color: #2d3748; display: block; font-weight: bold; margin-bottom: 2px;\"\u003eBackplane Verification and Keying\u003c\/span\u003e \u003cspan style=\"color: #2d3748;\"\u003eInspect the mechanical alignment keys on the target TP830 base unit. Ensure the keying index perfectly matches the processor unit profile to prevent mechanical component mismatching.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; position: relative; padding-left: 40px;\"\u003e\n\u003cdiv style=\"position: absolute; left: 0; top: 0; width: 28px; height: 28px; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; text-align: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n\u003cspan style=\"color: #2d3748; display: block; font-weight: bold; margin-bottom: 2px;\"\u003eMechanical Seating and Latching\u003c\/span\u003e \u003cspan style=\"color: #2d3748;\"\u003eAlign the PM858K02 module parallel with the housing guides. Push the processor straight downward onto the baseplate connector pins until the integrated lock mechanisms audibly engage and secure the module frame.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; position: relative; padding-left: 40px;\"\u003e\n\u003cdiv style=\"position: absolute; left: 0; top: 0; width: 28px; height: 28px; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; text-align: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n\u003cspan style=\"color: #2d3748; display: block; font-weight: bold; margin-bottom: 2px;\"\u003eNetwork and Fiber Interconnection\u003c\/span\u003e \u003cspan style=\"color: #2d3748;\"\u003eInsert the redundant RJ45 Ethernet communication cables into ports primary and secondary. For redundant configurations, ensure the dedicated RCU-link interconnect cables are fully coupled between the primary and backup modules.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; position: relative; padding-left: 40px;\"\u003e\n\u003cdiv style=\"position: absolute; left: 0; top: 0; width: 28px; height: 28px; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; text-align: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n\u003cspan style=\"color: #2d3748; display: block; font-weight: bold; margin-bottom: 2px;\"\u003ePower-On Sequence and Diagnostics\u003c\/span\u003e \u003cspan style=\"color: #2d3748;\"\u003eEnergize the underlying 24V DC supply lines. Observe the integrated LED status indicators: the \"Run\" indicator must switch to solid green, and the \"Fault\" indicator must remain dark after completing internal firmware self-checks.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53357803405675,"sku":"3BSE082896R1 PM858K02","price":8000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PM858K02.png?v=1780891182","url":"https:\/\/www.plcprotech.com\/ar\/products\/abb-ac-800m-3bse082896r1-pm858k02-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}