{"product_id":"bently-nevada-3500-15-133292-01-low-voltage-dc-power-supply-module","title":"بنتلي نيفادا 133292-01 وحدة تزويد طاقة تيار مستمر منخفض الجهد","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e133292-01\u003c\/strong\u003e is a half-height hardware module designed to supply stable and regulated power within the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. It functions as a legacy low-voltage power regulation unit, converting low-voltage direct current input source feeds into predefined voltage profiles mandatory for running adjacent condition monitoring and rack processing modules. Positioned specifically within dedicated slots on the far left side of a standardized rack chassis, this hardware option can work as a standalone power source or operate in parallel configuration with a secondary matching card to deliver uninterrupted system redundancy. The card accepts specialized low-voltage DC inputs via a corresponding rear-mounted Power Input Module (\u003cstrong\u003ePIM\u003c\/strong\u003e), making it an essential replacement spare across automated manufacturing frameworks, petrochemical facilities, and heavy turbomachinery installations requiring high-availability monitoring infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHalf-height physical design footprint to fit designated left-side power slots of the chassis framework.\u003c\/li\u003e\n\u003cli\u003eIntegrates dual-supply redundancy mode with automatic primary\/backup switching logic when installed with a secondary module.\u003c\/li\u003e\n\u003cli\u003eHot-swappable installation architecture enabling direct replacement of a damaged block without disturbing active machinery protection loops.\u003c\/li\u003e\n\u003cli\u003eBuilt-in front-facing diagnostics with a dedicated LED utility status light indicating proper module regulation performance.\u003c\/li\u003e\n\u003cli\u003eComprehensive under-voltage safety measures engineered to safeguard interior multi-layer circuit boards from electrical faults.\u003c\/li\u003e\n\u003cli\u003eHigh compatibility with legacy low-voltage DC backplane distributions for efficient hardware migration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePowering machinery protection racks on remote oil and gas transport pipelines driven by low-voltage DC batteries.\u003c\/li\u003e\n\u003cli\u003ePower distribution management for localized rotating asset vibration arrays inside petrochemical processing units.\u003c\/li\u003e\n\u003cli\u003ePower provisioning for critical turbine and generator tracking networks utilizing standalone solar or battery bank utilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/15-AA-BB-CC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete Power Supply assembly ordering structure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy Low Voltage DC (20 to 30 Vdc) option for Top Slot.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy Low Voltage DC (20 to 30 Vdc) option for Bottom Slot.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: None.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: CSA\/NRTL\/C (Class 1, Division 2).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: ATEX \/ IECEX \/ CSA (Class 1, Zone 2).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e133292-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpare Parts:\u003c\/strong\u003e Legacy Low Voltage DC Power Supply Module.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e133300-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpare Parts:\u003c\/strong\u003e Legacy Low Voltage DC Power Input Module.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01720045\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpare Parts:\u003c\/strong\u003e Replacement Fuse (Low Voltage DC Power Input Module and Legacy Low Voltage DC Power Input Module).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpare Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e133292-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 to 30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Rack Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnder-Voltage Fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupply protected, no damage occurs to module or PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-Voltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTriggers open status on the designated PIM primary fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Loading\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo minimum rack load is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Module Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Module Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.7 mm (4.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Module Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e251.5 mm (9.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.39 kg (3.06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe interface layout manages power supply statuses and connection tracking on the chassis system:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description \/ Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSUPPLY OK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel status light; glows steadily green when internal rails generate appropriate voltage outputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTop Card Slot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesignated slot container on the left side of the framework acting as the secondary\/backup bay.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBottom Card Slot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesignated slot container on the left side of the framework acting as the primary system power position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear PIM Board Mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecialized receiver point located directly behind the card to capture incoming low-voltage DC lines.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Allocation:\u003c\/strong\u003e Mount the unit exclusively inside the designated half-height slot windows located on the left side of the main rack assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Priority:\u003c\/strong\u003e Populate the lower half-height bay to assign the hardware module as the primary supply source, or utilize the upper bay position for backup purposes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIM Matching:\u003c\/strong\u003e Always pair the \u003cstrong\u003e133292-01\u003c\/strong\u003e supply module with its correct corresponding legacy low-voltage DC backplane PIM (part number 133300-01) to avoid electrical mismatches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Execution:\u003c\/strong\u003e Ensure that a separate active power supply card remains online within the opposite power bay before removing or executing a live swap of this item.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Maintenance:\u003c\/strong\u003e If an over-voltage condition happens, check and swap the dedicated protection fuse (part number 01720045) on the associated backplane interface module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Low Voltage Directive 2014\/35\/EU, EN 61010-1 Standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e 2011\/65\/EU European Compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e DNV GL rules for classification, ABS Steel Vessels Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American Approvals:\u003c\/strong\u003e cNRTLus Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx Approvals:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the functional difference between 133292-01 and the updated high-efficiency DC power modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 133292-01 is a legacy-type low-voltage DC module designed specifically for older styles of 3500 power distributions and it is explicitly incompatible with standard newer low-voltage DC Power Input Modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware module require a minimal electrical load to maintain safe voltage output levels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the processing topology of the card means no minimum rack load is required for proper circuit regulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill a temporary low-voltage sag on the incoming 24V bus destroy the internal components?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, an under-voltage input variance does not cause operational harm or permanent degradation to the internal component hardware or the coupled PIM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I operate an AC power supply and a 133292-01 low-voltage DC module together inside the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the monitor chassis supports hosting any combination of alternating current and direct current power modules in the dual slots to form a highly versatile redundant configuration.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517651819,"sku":"133292-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-133292-01-low-voltage-dc-power-supply-module-cxxxu02b1cn_a888c3aa-81d1-43f2-ba03-bd0e04a3fa6b.jpg?v=1765440107","url":"https:\/\/www.plcprotech.com\/ar\/products\/bently-nevada-3500-15-133292-01-low-voltage-dc-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}