{"product_id":"mitsubishi-electric-fx3u-48mr-ds-fx3u-series-programmable-controller","title":"FX3U-48MR\/DS | ميتسوبيشي إلكتريك | وحدة تحكم قابلة للبرمجة سلسلة FX3U","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered to handle complex automation tasks in modern industrial environments, the \u003cstrong\u003eFX3U-48MR\/DS\u003c\/strong\u003e is a high-performance base unit belonging to the renowned MELSEC FX3U series of programmable logic controllers. This compact PLC features a robust configuration of 24 digital inputs and 24 relay outputs, making it highly suitable for applications requiring reliable mechanical switching and high-speed control logic. Operating on a 24V DC power supply, this controller provides exceptional processing speeds and flexible expansion capabilities through its unique dual-bus architecture, allowing seamless integration with additional digital, analog, and network communication adapters.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-speed execution time of 0.065 microseconds per basic instruction.\u003c\/li\u003e\n  \u003cli\u003eLarge internal program memory of up to 64,000 steps for complex control logic.\u003c\/li\u003e\n  \u003cli\u003eIntegrated 24 digital inputs (24V DC, sink or source configurable).\u003c\/li\u003e\n  \u003cli\u003eIntegrated 24 mechanical relay outputs (rated up to 2A per point).\u003c\/li\u003e\n  \u003cli\u003eSupport for high-speed counter inputs (up to 100 kHz) and positioning tasks.\u003c\/li\u003e\n  \u003cli\u003eDual-bus system structure allowing simultaneous connection of FX series expansion blocks and high-speed FX3U special adapters.\u003c\/li\u003e\n  \u003cli\u003eInherent maintenance-free operation with integrated real-time clock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConveyor and material handling systems\u003c\/li\u003e\n  \u003cli\u003ePackaging and labeling machines\u003c\/li\u003e\n  \u003cli\u003eFood and beverage processing equipment\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater pump control\u003c\/li\u003e\n  \u003cli\u003eHVAC and building automation networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFX3U-48MR\/DS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eController Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMELSEC FX3U\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24V DC (+20% \/ -15%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIntegrated Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 points (24V DC, sink\/source)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIntegrated Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 points (Relay, 2A\/point, 8A maximum per common terminal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal I\/O Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e48 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExecution Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.065 microseconds (basic instruction)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgram Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64,000 steps (RAM \/ Flash memory cassette optional)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRS-422 (built-in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35mm DIN Rail or direct screw mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Block Label\u003c\/th\u003e\n      \u003cth\u003eFunction Assignment\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e24V \/ 0V\u003c\/td\u003e\n      \u003ctd\u003eMain DC power supply input terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eS\/S\u003c\/td\u003e\n      \u003ctd\u003eInput signal common terminal (Sink or Source selection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eX0 to X27\u003c\/td\u003e\n      \u003ctd\u003eDigital input connection points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eY0 to Y27\u003c\/td\u003e\n      \u003ctd\u003eRelay output connection points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM0 to COM5\u003c\/td\u003e\n      \u003ctd\u003eCommon reference terminals for relay outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtective Ground (PE)\u003c\/td\u003e\n      \u003ctd\u003eSystem safety grounding point\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure all incoming power lines are disconnected before performing installation or wiring work.\u003c\/li\u003e\n  \u003cli\u003eMount the unit horizontally on a standard 35mm DIN rail or via direct mounting screws onto a flat panel.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum ventilation clearance of 50mm above, below, and on the sides of the PLC to prevent heat buildup.\u003c\/li\u003e\n  \u003cli\u003eKeep signal and high-voltage AC cables in separate cable ducts to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003eConnect the protective ground terminal to a dedicated class D ground (resistance of 100 ohms or less).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE (EMC and Low Voltage Directive)\u003c\/li\u003e\n  \u003cli\u003eUL \/ cUL Listed\u003c\/li\u003e\n  \u003cli\u003eKC (Korean Certification)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102147961195,"sku":"FX3U-48MR\/DS","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FX3U-48MR-DS-gq2fisedlpj.png?v=1776137543","url":"https:\/\/www.plcprotech.com\/ar\/products\/mitsubishi-electric-fx3u-48mr-ds-fx3u-series-programmable-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}