{"product_id":"abb-89as30r0100-gkwn000317r0100-procontrol-p14-analog-signal-multiplier","title":"ABB 89AS30R0100 GKWN000317R0100 Procontrol P14 Analog Signal Multiplier","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 89AS30R0100\u003c\/strong\u003e (Order Number \u003cstrong\u003eGKWN000317R0100\u003c\/strong\u003e) is an analog signal multiplier module designed for converting and multiplying analog signals within the Procontrol P14 control system. Operating with three independent function units, this device processes input signals of 0... 20 mA, 4 ... 20 mA, or 0... 10 V DC, with configurable selection available via jumpers. From each input, the unit generates three isolated current outputs (0... 20 mA or 4 ... 20 mA) and one voltage output (0... 10 V DC). Inputs feature electrical isolation from the internal circuitry and incorporate dedicated 15 V DC or 24 V DC transmitter power supply outputs.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree identical and independent function units\u003c\/li\u003e\n\u003cli\u003eJumper-selectable input signal ranges for current or voltage\u003c\/li\u003e\n\u003cli\u003eIndividually selectable current output ranges per channel via jumpers\u003c\/li\u003e\n\u003cli\u003eElectrically isolated inputs and separated outputs\u003c\/li\u003e\n\u003cli\u003eIntegrated 15 V DC and 24 V DC power supply for transmitters and field devices\u003c\/li\u003e\n\u003cli\u003eFront-panel green LED operation status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAnalog signal conversion and isolation\u003c\/li\u003e\n\u003cli\u003eSignal duplication for redundant monitoring or control circuits\u003c\/li\u003e\n\u003cli\u003eTransmitter power supply and signal processing in DCS environments\u003c\/li\u003e\n\u003cli\u003eSteam power generation and industrial automation control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eType Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e89AS30R0100\u003c\/td\u003e\n\u003ctd\u003eGKWN000317R0100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89AS30R0100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGKWN000317R0100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapprox. 110 mA + output currents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Input (E1, E2, E3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 10 V (max. 30 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Input (E1, E2, E3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 20 mA, 4 ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Resistance (Input Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Supply (US1, US2, US3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 V DC or 24 V DC, max. 25 mA (jumper selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Outputs (A11 to A13, A21 to A23, A31 to A33)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 20 mA, 4 ... 20 mA (jumper selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Burden (Current Outputs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Outputs (A14, A24, A34)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 10 V (max. 12 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Current (Voltage Outputs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage \/ Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity (Operating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAtmospheric Pressure (Operating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86 kPa to 106 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoard Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 units, 1 division, 160 mm deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 48-pole edge connector, type F (to DIN 41 612\/IEC 60603-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapprox. 0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed02 \/ b02 \/ z02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput E3+ \/ Input E2+ \/ Input E1+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed04 \/ b04 \/ z04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput E3- \/ Input E2- \/ Input E1-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed06 \/ b06 \/ z06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransmitter Supply US3+ \/ US2+ \/ US1+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed08 \/ b08 \/ z08\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransmitter Reference Z3 \/ Z2 \/ Z1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed12 \/ b12 \/ z12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput A31+ \/ Output A21+ \/ Output A11+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed14 \/ b14 \/ z14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput A31- \/ Output A21- \/ Output A11-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed16 \/ b16 \/ z16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput A32+ \/ Output A22+ \/ Output A12+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed18 \/ b18 \/ z18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput A32- \/ Output A22- \/ Output A12-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed20 \/ b20 \/ z20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput A33+ \/ Output A23+ \/ Output A13+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed22 \/ b22 \/ z22\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput A33- \/ Output A23- \/ Output A13-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed24 \/ b24 \/ z24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput A34+ \/ Output A24+ \/ Output A14+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed26 \/ b26 \/ z26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput A34- \/ Output A24- \/ Output A14-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed30 \/ b30 \/ z30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReference potential Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ed32 \/ b32 \/ z32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower supply USA \/ USA \/ USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify jumper positions on the board prior to insertion to configure input signal ranges, output ranges, and transmitter supply voltages.\u003c\/li\u003e\n\u003cli\u003eEnsure power is disconnected before installing or removing the module from the 48-pole DIN 41 612 \/ IEC 60603-2 rack connector.\u003c\/li\u003e\n\u003cli\u003eObserve transducer power limits when wiring four-core transducers; total current consumption per supply output must remain below 25 mA.\u003c\/li\u003e\n\u003cli\u003eMaintain operating environment conditions between 0 and +70 degC with relative humidity levels between 5% and 95% non-condensing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EC\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-4: 2007\/A1:2011 (EMC Emission - Industry)\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-2: 2005\/AC:2005 (EMC Immunity - Industry)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53650197152107,"sku":"89AS30R0100 GKWN000317R0100","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-gkwn000317r0100.jpg?v=1785665819","url":"https:\/\/www.plcprotech.com\/az\/products\/abb-89as30r0100-gkwn000317r0100-procontrol-p14-analog-signal-multiplier","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}