{"product_id":"bently-nevada-106m1081-01-3500-15-universal-ac-power-input-module","title":"Bently Nevada 106M1081-01 3500\/15 Universal AC Power Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e106M1081-01\u003c\/strong\u003e Universal AC Power Input Module (PIM) is a rear-mount power interface module engineered for the \u003cstrong\u003eBently Nevada 3500\/15\u003c\/strong\u003e AC and DC Power Supplies system. Positioned in the rear slot directly behind its associated front-facing power supply module, the \u003cstrong\u003e106M1081-01\u003c\/strong\u003e receives line AC power and routes it to the \u003cstrong\u003e106M1079-01\u003c\/strong\u003e Universal AC Power Supply module. It converts incoming AC line voltage into acceptable operating levels for the 3500 Series Machinery Protection System rack. Note that the \u003cstrong\u003e106M1081-01\u003c\/strong\u003e Universal AC PIM is not compatible with legacy 3500 AC power supplies or legacy AC power input modules.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts nominal 110 to 220 Vac input with wide operating limits (85 to 264 Vac rms for non-hazardous areas, 85 to 250 Vac rms for hazardous areas).\u003c\/li\u003e\n\u003cli\u003eDedicated half-height module design installed directly behind the matching front-facing power supply module.\u003c\/li\u003e\n\u003cli\u003eOperates in combination with the 3500\/15 Universal AC Power Supply module (\u003cstrong\u003e106M1079-01\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eIntegrated over-voltage protection via fuse located on the power input module.\u003c\/li\u003e\n\u003cli\u003eBuilt-in protection ensuring under-voltage conditions cause no damage to the module or power supply.\u003c\/li\u003e\n\u003cli\u003eSupports seamless module insertion and removal without interrupting rack operation in dual-redundant power configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC-powered 3500 Series Machinery Protection System racks.\u003c\/li\u003e\n\u003cli\u003eTurbomachinery vibration, axial position, and condition monitoring systems.\u003c\/li\u003e\n\u003cli\u003eContinuous critical machinery protection in power generation, oil and gas, and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \/ Baker Hughes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106M1081-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal AC Power Input Module (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/15 Power Supply System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 to 220 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range (Non-hazardous)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 264 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range (Hazardous)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 250 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 to 373 Vac pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Rack Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 A rms (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-Voltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse opens on the PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnder-Voltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder-voltage does not harm supply or PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Fuse Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120M3877 (Fast blow rated at 5A\/500 Vac, Size 6.3 x 32 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Connector Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118M0915-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting Location:\u003c\/strong\u003e Mount the module in the special half-height rear slot located directly behind the associated 3500\/15 Universal AC Power Supply module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Operations:\u003c\/strong\u003e In dual-supply rack setups, inserting or removing either power supply module will not interrupt rack operation as long as a secondary supply is active.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage and Wiring Security:\u003c\/strong\u003e Ensure AC supply lines adhere to specified input voltage limits (85 to 264 Vac rms non-hazardous \/ 85 to 250 Vac rms hazardous) and frequency range (47 to 63 Hz).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Maintenance:\u003c\/strong\u003e If an over-voltage condition causes the module fuse to open, replace it using verified replacement fuse part number \u003cstrong\u003e120M3877\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility Check:\u003c\/strong\u003e Verify that the front power supply module is the matching \u003ca href=\"https:\/\/www.plcprotech.com\/products\/bently-nevada-106m1079-01-3500-15-universal-ac-power-supply-module\"\u003e\u003cstrong\u003e106M1079-01\u003c\/strong\u003e\u003c\/a\u003e Universal AC Power Supply, as legacy AC modules are incompatible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Part 15 Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Condition of Classification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx:\u003c\/strong\u003e Ex II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860863851,"sku":"106M1081-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-106m1081-01-universal-ac-power-input-module-2iscrzxamv1_ee5a5891-57ac-4c7e-a824-63ebbae2a446.jpg?v=1765449293","url":"https:\/\/www.plcprotech.com\/az\/products\/bently-nevada-106m1081-01-3500-15-universal-ac-power-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}