{"product_id":"bently-nevada-172109-01-3500-65-16-channel-temperature-monitor-i-o-module","title":"Bently Nevada 172109-01 3500\/65 16-Channel Temperature Monitor I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 172109-01\u003c\/strong\u003e is a full-height rear I\/O module designed for use with the \u003cstrong\u003e3500\/65 16-Channel Temperature Monitor\u003c\/strong\u003e within the 3500 Machinery Protection System. The \u003cstrong\u003e172109-01\u003c\/strong\u003e provides external termination interface connections to accept up to 16 temperature transducer inputs, supporting both resistance temperature detector (RTD) and isolated tip thermocouple (TC) field inputs. It conditions temperature transducer signals and passes them to the 3500\/65 main card for alarm comparison and machinery health monitoring across industrial applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExternal termination design for routing field inputs via external termination blocks and cables\u003c\/li\u003e\n\u003cli\u003eAccepts 1 to 16 RTD or isolated tip thermocouple signals\u003c\/li\u003e\n\u003cli\u003eDirect compatibility with the 3500\/65 16-Channel Temperature Monitor main card\u003c\/li\u003e\n\u003cli\u003eFull-height rear slot footprint in standard and bulkhead 3500 rack configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-channel temperature monitoring for industrial rotating machinery\u003c\/li\u003e\n\u003cli\u003eBearing, stator, and winding temperature detection in turbines, motors, and generators\u003c\/li\u003e\n\u003cli\u003eMachinery protection system integration within Bently Nevada 3500 racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e172109-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/65 RTD\/Isolated Tip TC I\/O Module, External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e172115-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD\/Isolated Tip TC External Termination Block (Euro Style Connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e134544-AAAA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/65 Transducer (XDCR) Signal to External Termination (ET) Block Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter Category\u003c\/th\u003e\n\u003cth\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e172109-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 to 16 RTD or isolated tip TC transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Transducer Types (TC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType E (-100 degC to +1000 degC); Type J (0 degC to +760 degC); Type K (0 degC to +1370 degC); Type T (-160 degC to +400 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Transducer Types (RTD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ohm 3-wire and 4-wire platinum (alpha = 0.00385) (-200 degC to +850 degC); 100 Ohm 3-wire and 4-wire platinum (alpha = 0.00392) (-200 degC to +700 degC); 120 Ohm 3-wire and 4-wire nickel (-80 degC to +260 degC); 10 Ohm 3-wire and 4-wire copper (-100 degC to +260 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreater than 1 MOhm for each lead input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBulkhead Rack: +\/-3 degC at +25 degC; Standard Rack: +\/-3 degC at +25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-2 degC at +25 degC (used for TC measurements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTD Current Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e913 +\/- 7 uA at +25 degC per transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 watts nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Install the 172109-01 into a full-height rear slot directly behind the 3500\/65 main module position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable and Termination Wiring:\u003c\/strong\u003e Connect the I\/O module to the 172115-01 external termination block using approved 134544 cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Requirements:\u003c\/strong\u003e Ensure system firmware compatibility (3500\/22 Revision 1.50 or later, 3500\/01 Software Version 3.85 or later). When replacing older I\/O modules with revision 172109-01 Rev D or later, upgrade the monitor firmware after removing the module to avoid mismatch errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Compatibility:\u003c\/strong\u003e Do not use external termination blocks with internal termination I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of FCC Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e RoHS Directive 2011\/65\/EU; China RoHS EFUP designation of 15 years per SJ\/T 11364-2024\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e cNRTLus Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 at Ta = -20 degC to +65 degC); ATEX\/IECEx Ex II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc (T4 at Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e ABS-Marine and Offshore Applications; DNV GL Rules for Classification (Ships, Offshore Units, and High Speed and Light Craft)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666618806635,"sku":"172109-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-172109-01-isolated-tip-tc-i-o-module-jf0abonx0vd_05f8cff5-294e-4930-802c-36513e693d70.jpg?v=1765444229","url":"https:\/\/www.plcprotech.com\/az\/products\/bently-nevada-172109-01-3500-65-16-channel-temperature-monitor-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}