{"product_id":"honeywell-lg1093aa04-lg1093-uv-flame-sensor","title":"Honeywell LG1093AA04 LG1093 UV Flame Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell LG1093AA04\u003c\/strong\u003e is a ultraviolet (UV) flame sensor designed for flameout protection in industrial gas turbine applications. As part of the \u003cstrong\u003eLG1093\u003c\/strong\u003e sensor family, the \u003cstrong\u003eLG1093AA04\u003c\/strong\u003e utilizes a Geiger Mueller-type sensor phototube to detect ultraviolet radiation emitted by hydrocarbon flames in the 1800 to 2600 angstrom spectrum. The sensor is engineered to be solar blind and tolerant to black body radiation, producing a precise output signal to indicate flame presence or absence to the monitoring system. This unit features a 3\/4 inch internal NPT mounting interface and comes equipped with a 16-foot (4.9 m) Teflon shielded cable with a 1-inch external conduit thread for integration with flame monitoring control panels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeiger Mueller-type sensor phototube detecting ultraviolet radiation at 1800 to 2600 angstroms\u003c\/li\u003e\n\u003cli\u003eSolar blind operation with tolerance to black body radiation\u003c\/li\u003e\n\u003cli\u003eFast response time (0.1 sec typical response when paired with EG1033 amplifier)\u003c\/li\u003e\n\u003cli\u003eLong operational life with 10,000 hours MTBF and 2-year shelf life\u003c\/li\u003e\n\u003cli\u003e3\/4 inch internal NPT mounting interface\u003c\/li\u003e\n\u003cli\u003eIntegrated 16-foot (4.9 m) Teflon shielded cable with 1 inch external conduit thread\u003c\/li\u003e\n\u003cli\u003eOperating capability up to 1000 feet distance from sensor to amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial power generation gas turbines\u003c\/li\u003e\n\u003cli\u003eGas turbine pumping stations\u003c\/li\u003e\n\u003cli\u003eShip-board power generation systems\u003c\/li\u003e\n\u003cli\u003eHydrocarbon flame monitoring in industrial power plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLG1093AA04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeiger Mueller-type phototube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 to 2600 angstroms (UV band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4 inch internal NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Panel Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeflon shielded cable with 1 inch external conduit thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 ft (4.9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degF to +350 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWindow Pressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 psig at 400 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Distance to Amplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShelf Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the sensor onto the turbine housing via the 3\/4 inch internal NPT mounting interface.\u003c\/li\u003e\n\u003cli\u003eEnsure the optical window and mounting location maintain clean sight lines to the hydrocarbon flame zone.\u003c\/li\u003e\n\u003cli\u003eRoute the integrated 16-foot Teflon shielded cable through protective 1-inch external conduit threading to the control panel.\u003c\/li\u003e\n\u003cli\u003eMaintain maximum wiring distance within 1000 feet between the sensor unit and the associated EG1033 amplifier.\u003c\/li\u003e\n\u003cli\u003eEnsure proper conduit sealing when installing in hazardous or explosive atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Mutual (FM):\u003c\/strong\u003e Explosion Proof Class I, Divisions 1 and 2, Groups B, C and D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e EMC Directive 89\/336\/EEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Directive:\u003c\/strong\u003e 94\/9\/EC II 2G EEx d IIA T3 or EEx d IIC T3 (Models AA34\/35\/36\/44\/45\/46)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53644231147883,"sku":"LG1093AA04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/LG1093AA04.jpg?v=1785594702","url":"https:\/\/www.plcprotech.com\/az\/products\/honeywell-lg1093aa04-lg1093-uv-flame-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}