{"title":"Bently Nevada 7200 \u0026 3300 Interconnect Cables","description":"\u003cp\u003eBently Nevada 7200 \u0026amp; 3300 Interconnect Cables are specialized wiring solutions designed to maintain compatibility and signal integrity across different generations of monitoring hardware. The architecture includes high-quality shielding and specific connector terminations that bridge the gap between legacy \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-system-monitoring\"\u003e3300 system monitoring\u003c\/a\u003e units and modern sensors. Technical characteristics feature low resistance and high-dielectric strength, ensuring that raw vibration signals are transmitted without noise interference. Functionally, these cables allow plants to maintain older machinery protection systems while integrating newer \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-xl-proximitor-sensor\"\u003e3300 XL Proximitor sensors\u003c\/a\u003e or seismic transducers. They serve as a critical link in the monitoring chain, ensuring that data from the machine floor reaches the control room accurately, supporting long-term asset lifecycle management.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-9571-32-standard-interconnect-cable","title":"Bently Nevada 9571-32 Standard Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e9571-32\u003c\/strong\u003e is a rugged, industrial-grade \u003cstrong\u003estandard interconnect cable\u003c\/strong\u003e designed for high-reliability signal transmission within machinery condition monitoring systems. Engineered to link machinery sensors or transmitters directly to asset protection monitors and processing racks, this cable ensures the uncompromised delivery of critical vibration, position, and speed raw waveforms. The model \u003cstrong\u003e9571-32\u003c\/strong\u003e utilizes a premium 22 AWG 2-conductor twisted, shielded pair architecture wrapped in a durable insulation layer to safeguard data integrity against aggressive electromagnetic interference (EMI) and radio frequency interference (RFI) common in plant environments.\u003c\/p\u003e\n\u003cp\u003eThe assembly features a factory-terminated, moisture-resistant 2-socket female connector block at one end to interface securely with field transducers, and standard bare wire terminal lugs at the opposing end for streamlined connection inside local monitor racks or termination blocks. The \u003cstrong\u003e-32\u003c\/strong\u003e suffix denotes a specific physical length of exactly 32 feet (approximately 9.7 meters). This cable is fully rated for continuous industrial operation across wide temperature variations, delivering stable signal dynamics for critical rotating assets without contributing data loss or capacitive distortion.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-integrity 2-conductor twisted, shielded pair configuration to block high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eFactory-installed 2-socket moisture-resistant female connector providing tight environment sealing at the transducer end.\u003c\/li\u003e\n\u003cli\u003ePre-installed terminal ring lugs at the monitor end for quick, reliable terminal strip mounting.\u003c\/li\u003e\n\u003cli\u003eRugged 22 AWG high-conductivity copper core layout maximizing signal path transmission efficiency.\u003c\/li\u003e\n\u003cli\u003eFlexible, orientation-agnostic construction allowing easy pathing through tightly packed wire tracks and conduits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnecting casing vibration velocity sensors or accelerometers to remote monitor frames.\u003c\/li\u003e\n\u003cli\u003eInterfacing field-mounted vibration transmitters directly with host control system analog cards.\u003c\/li\u003e\n\u003cli\u003eRouting dynamic diagnostic transducer lines through local junction cabinets to centralized monitoring panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571 (Standard Interconnect Cable Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-32 (Specified length of 32 feet \/ 9.75 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Twisted Shielded Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (Approximately 0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-conductor twisted pair with integrated drain wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull coverage aluminum-polyester shield line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-socket moisture-resistant molded female connector block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard pre-crimped terminal ring lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 300 V RMS operational insulation capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pull Tension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.2 lbs (17.8 kg) structural limit rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial performance envelope from -29 to 121 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStationary Minimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.28 in. (57.9 mm) mechanical limitation path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 ft. (9.75 m) fixed option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Compatibility Restriction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot for use inside 21128 Velocity Transducer Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNet weight approximately 0.8 kg (1.76 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable End Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePhysical Interface Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Transducer Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded 2-socket female connector with threaded locking mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Panel Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate positive, negative, and shield drain ring terminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Route Planning:\u003c\/strong\u003e Pull the cable assembly through dedicated low-voltage instrument conduits. Ensure it is path-isolated from high-current motor supply wires to minimize capacitive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer End Threading:\u003c\/strong\u003e Align the 2-socket female connector pins accurately with the sensor output pins. Tighten the connector sleeve to establish a compressed, moisture-resistant environmental seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Compliance:\u003c\/strong\u003e Maintain a physical path layout radius greater than 2.28 in. (57.9 mm) at all enclosure entry joints to prevent structural core strain or shielding separation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Drain Grounding:\u003c\/strong\u003e Terminate the instrument shield drain wire only at one designated common ground reference point (typically inside the monitor rack terminal block) to avoid generating problematic ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526957931,"sku":"9571-32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-32-cable-yfifvsfafj0_9f55ffc9-d680-4e6b-92ad-ee7e476cf3fd.jpg?v=1765440291"},{"product_id":"bently-nevada-9571-17-interconnect-cable","title":"Кабел за свързване Bently Nevada 9571-17","description":"\u003ch3\u003eОписание\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eBently Nevada 9571-17 е здрав, стандартен кабелен комплект за свързване, оптимизиран за мониторинг на състоянието на индустриални машини и проследяване на вибрации. Проектиран с \u003cstrong\u003eдвупроводников усукан и екраниран чифт\u003c\/strong\u003e с висококачествени проводници 22 AWG, този здрав кабел служи като основна сигнална връзка между преобразуватели – като сензорите Velomitor с пиезо-скорост или специализирани нискочестотни акселерометри – и монитори за близост или вибрации. Разполага с интегриран 2-щифтов влагозащитен женски конектор на страната към сензора и подготвени клемни пръстени на задния интерфейс за чисто свързване в шкафа. Проектиран да издържа на тежки индустриални условия, този инструментален кабел осигурява оптимално екраниране за отхвърляне на електромагнитни смущения (EMI) и радиочестотни смущения (RFI) по дълги полеви трасета. Опцията с код 17 определя точна фиксирана дължина от 17 фута (5,2 метра), за да поддържа постоянен контрол на импеданса в персонализирани системни конфигурации без излишно навиване на кабела.\u003c\/p\u003e\n\n\u003ch3\u003eХарактеристики\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eДвойно усукана екранирана конструкция:\u003c\/strong\u003e Дизайн с двойни проводници 22 AWG минимизира индуктивни смущения и шум от пресичане по дълги индустриални сигнални линии.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eВлагозащитена връзка:\u003c\/strong\u003e Оборудван с презалепен 2-щифтов женски конектор на полевия край, който предотвратява проникване на течности в влажна среда.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eПредварително завършени клеми за мониторинг:\u003c\/strong\u003e Разполага с издръжливи клемни пръстени от страната на шкафа за директно свързване към клемни ленти без необходимост от кримпване на място.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eШирок температурен диапазон:\u003c\/strong\u003e Проектиран да издържа на непрекъснати експозиции при работни температури от -29 °C до +121 °C.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eОптимизирана дължина на системата:\u003c\/strong\u003e Предварително изрязаният вариант от 17 фута предотвратява излишното съхранение на кабел и осигурява свързване от точка до точка на полето.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eПриложения\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eСвързване на сензори Velomitor с пиезо-скорост с дистанционни диагностични монитори или системи за непрекъснат мониторинг.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eСистеми за мониторинг на машини в съоръжения за добив на нефт и газ, петрохимически рафинерии и общински помпени станции.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eКритични абсолютни вибрационни вериги на корпуса при високоскоростно въртящо се оборудване, големи охладителни вентилатори и индустриални помпи.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eПолево прокарване в защитени тръбни трасета, където силни ЕМИ смущения изискват висококачествени дренажни екрани.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eИнформация за поръчка\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eКод на модела\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eОпция за конфигурация\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eОписание на техническата стойност\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e9571\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eМодел на основната сборка\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eСтандартен междумодулен кабел (2-проводников, 22 AWG, екраниран)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e-17\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eОбозначение на дължината на кабела\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e17 фута (5,2 метра) непрекъсната дължина\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eТехнически спецификации\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eПараметър\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eСтойност по спецификация\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eКалибър на проводника\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e22 AWG (0,382 мм2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eПодредба на жилата\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eУсукан чифт с 2 проводника с интегриран дренажен проводник\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eКрай на полевата връзка\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eВлагозащитен женски формован конектор с 2 гнезда\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eКрай на връзката към монитор\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eПредварително монтирани пръстеновидни клеми\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eРаботен температурен диапазон\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-29 °C до +121 °C (-20 °F до +250 °F)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eМаксимално допустима системна верига\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eМаксимална обща дължина 305 метра (1000 фута) при съвпадение с одобрен сензор\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eОграничения на приложението\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eНе е предназначено за използване вътре в корпуса на 21128 Velocity Transducer\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eПроизводител\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (компания на Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eДържава на произход\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eСАЩ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eТегло при доставка (изчислено)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2,0 кг\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eРазмери на опаковката (изчислени)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e280 мм x 280 мм x 25 мм\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eИнструкции за монтаж\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eКРИТИЧНО ПРЕДУПРЕЖДЕНИЕ\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eИзолирайте и напълно изключете захранването на системата за мониторинг на машината преди изтегляне, прокарване или завършване на инструменталното окабеляване. Работа с живи полеви сигнали близо до високоенергийни машини може да предизвика опасни повреди в системната верига, случайни спирания на процеса или електрически разряди.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eПолевите инженери трябва стриктно да спазват следната професионална последователност на свързване:\u003c\/p\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eПрокарайте кабела през специализирани, заземени стоманени тръбопроводи, за да изолирате усуканите двойки 22 AWG от захранванията на високоволтовите двигатели.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eПроверете влагозащитената женска глава с 2 гнезда за замърсявания, отломки или влага преди свързване с гнездото на корпуса на сензора.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eЗатегнете женската резба плътно върху гнездото на сензора, за да създадете напълно запечатана бариера срещу проникване на течности.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eЗаземете задните пръстеновидни клеми здраво върху клемните блокове вътре в панелния корпус, като закрепите защитния проводник към определената точка за заземяване на инструментите.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666534232427,"sku":"9571-17","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-17-interconnect-cable-l321dmvfk5l_98ba226c-f49e-40a1-bad8-c775e9af6fc1.jpg?v=1765440398"},{"product_id":"bently-nevada-89477-80-right-angle-interconnect-cable","title":"Кабел за правоъгълна връзка Bently Nevada 89477-80","description":"\u003ch3\u003eОписание\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 89477-80\u003c\/strong\u003e е здраво екранирано съединително кабелно изделие, проектирано да свързва инструментацията на машините с централизирани системи за мониторинг на машините. Този специализиран компонент за данъчни цикли е с обща дължина 80 фута (24,0 метра) и е изграден от здрави проводници с размер 0.963 mm2 (18 AWG), за да осигури стабилни характеристики на връзката на инструментацията. За да позволи чисти пътища на сигнала в тесни структурни пространства, като същевременно осигурява сигурно прилягане в некондиционирани, влажни работни зони, страната на връзката на трансдюсера разполага с фабрично интегриран влагоустойчив ъглов женски щепсел, допълнен със стандартизирани индустриални пръстеновидни уши на интерфейса за терминал на монитора. Многопроводниковата инфраструктура разполага с тежка защитна бариера за минимизиране на външни смущения от земни вериги и високочестотни шумови емисии, като защитава жизненоважни вибрационни и състояния на данни в изискващи индустриални температурни диапазони.\u003c\/p\u003e\n\u003ch3\u003eХарактеристики\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eСглобени с здрави вътрешни инструментационни кабели с размер 0.963 mm2 (18 AWG) и екраниране.\u003c\/li\u003e\n\u003cli\u003eПредварително завършени със специализиран влагоустойчив ъглов женски щепсел в края на пътя на трансдюсера.\u003c\/li\u003e\n\u003cli\u003eИнтегрирани здрави пръстеновидни уши на интерфейса на панела на мониторинговата система.\u003c\/li\u003e\n\u003cli\u003eПроектирани с премиум защитни пътища за блокиране на локални некондиционирани шумови емисии.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eПриложения\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eВисоконадеждни пътища за сигнализация на инструментация, свързващи сензори на полевото оборудване с основни монитори за състоянието на активите.\u003c\/li\u003e\n\u003cli\u003eПлътни терминални маршрути в пространството или некондиционирани процесни зони, изискващи ъглови влагоустойчиви връзки.\u003c\/li\u003e\n\u003cli\u003eНепрекъснати вибрационни цикли при критично индустриално въртящо се оборудване, изложено на широки климатични диапазони.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eИнформация за поръчка\u003c\/h3\u003e\n\u003cp\u003eСтруктурата на кода на модела за този кабелен комплект с конектор под прав ъгъл следва стандартизирана система за избор на дължина. Префиксът на частния номер е съчетан с конкретен двуцифрен суфикс, който показва общата дължина на кабела във футове.\u003c\/p\u003e\n\u003cp\u003eИзползвайте таблицата за конфигурация по-долу, за да идентифицирате или посочите точния номер на модела за поръчка според изискванията за дължина на вашата система:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eМодел за поръчка\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eДължина на кабела (фути)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eДължина на кабела (метри)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 фута\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 фута\u003c\/td\u003e\n\u003ctd\u003e3.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 фута\u003c\/td\u003e\n\u003ctd\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-17\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 фута\u003c\/td\u003e\n\u003ctd\u003e5.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 фута\u003c\/td\u003e\n\u003ctd\u003e6.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 фута\u003c\/td\u003e\n\u003ctd\u003e7.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 фута\u003c\/td\u003e\n\u003ctd\u003e9.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-33\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 фута\u003c\/td\u003e\n\u003ctd\u003e10.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 фута\u003c\/td\u003e\n\u003ctd\u003e15.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-80\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 фута\u003c\/td\u003e\n\u003ctd\u003e24.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-99\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 фута\u003c\/td\u003e\n\u003ctd\u003e30.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eТехнически спецификации\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eПараметър\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eСпецификация\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eПроизводител\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eКод на модела\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eТип продукт\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eКабел за свързване под прав ъгъл\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eДължина на кабела\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 фута (24,0 м)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eСечение на проводника\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.963 мм2 (18 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eТип кабелна конструкция\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eЕкранован\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eИнтерфейс за свързване на трансдюсера\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eВлагозащитен женски конектор под прав ъгъл\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eИнтерфейс за свързване на монитора\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eПръстеновидни накрайници\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eРаботен температурен диапазон\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 до 121 °C (-20 до 250 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eВръзки\/Интерфейси\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eПозиция на конектора\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eТип интерфейс за свързване\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eКрай на трансдюсера\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eВлагозащитен женски конектор под прав ъгъл\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eКрай на монитора\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eПръстеновидни накрайници\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eИнструкции за монтаж\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eРазположете 80-футовата инструментална верига по определените индустриални кабелни канали, като предотвратите остри механични огъвания или прекомерно триене при дърпане.\u003c\/li\u003e\n\u003cli\u003eНавийте и напълно поставете влагозащитения женски конектор под прав ъгъл върху терминала на корпуса на трансдюсера, за да завършите уплътнението срещу околната среда.\u003c\/li\u003e\n\u003cli\u003eЗакрепете здраво тежките пръстеновидни накрайници към терминалните релсови блокове вътре в шасито на системата за мониторинг, осигурявайки стабилно механично задържане.\u003c\/li\u003e\n\u003cli\u003eОтделете пътя за комуникация на сензора от високоволтовите захранващи проводници на основния мотор, за да предотвратите свързване на шумове от полето или преходни смущения в сигнала.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666538983787,"sku":"89477-80","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-89477-80-interconnect-cable-4h2fzgxxi5b_bca57e98-6d9a-4633-a2be-aa944da286d1.jpg?v=1765440447"},{"product_id":"bently-nevada-16925-12-330400-series-interconnect-cables","title":"Bently Nevada 16925-12 330400 Series Interconnect Cables","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16925-12\u003c\/strong\u003e specifies a 12-foot (3.6 m) 3-conductor shielded 22 AWG (0.5 mm2) interconnect cable, configured with a 3-socket plug at one end and terminal lugs at the other end. This configuration is used for transmitting high-frequency vibration signals from Bently Nevada 330400 and 330425 accelerometer transducers to permanent monitoring systems or dynamic signal analyzers.\u003c\/p\u003e\n\u003cp\u003eThe cable features a 22 AWG (0.5 mm2) conductor size, a protective shield to minimize electromagnetic interference (EMI), and terminal lugs for secure termination at the cabinet or receiver end. Unlike the heavier 18 AWG variant (130539) or the armored version (16710), the 16925 cable series provides a lightweight and flexible cabling option for standard industrial installations within protective conduit or enclosures. The 12-foot length is standard-configured to support intermediate-distance routing between the sensor and local junction boxes.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Configuration:\u003c\/strong\u003e 3-conductor shielded cable featuring 22 AWG (0.5 mm2) wire size for optimal signal integrity in high-frequency vibration monitoring applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 12 ft (3.6 m) standard length, providing the ideal distance for field installations requiring run-ups from bearing housings to local enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminations:\u003c\/strong\u003e 3-socket plug connection at one end to mate directly with 330400\/330425 sensors, and terminal lugs at the opposing end for terminal block integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Mitigation:\u003c\/strong\u003e Integrated shielding protects delicate dynamic signals against electromagnetic and radio-frequency interference (EMI\/RFI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Routing:\u003c\/strong\u003e Lightweight construction allows for easier bending and pulling through protective conduits or cable trays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is deployed across critical rotating machinery in demanding industrial environments, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Generation: Steam, gas, and hydro turbine bearing casing monitoring.\u003c\/li\u003e\n\u003cli\u003eOil and Gas: Centrifugal compressors, pumps, and gearboxes where casing acceleration is monitored.\u003c\/li\u003e\n\u003cli\u003ePetrochemical: Reciprocating machinery and fans requiring API 670 compliant measurements.\u003c\/li\u003e\n\u003cli\u003eGeneral Industrial: Balance of plant rotating machinery casing vibration protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\/Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16925-12\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded 22 AWG interconnect cable (12 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption A (Cable Length)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12 ft (3.6 m) standard length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16925-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded interconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 ft (3.6 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnd A Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-socket plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnd B Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Transducers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 330400 and 330425 Accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 ft (0.6 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure precise signal transmission and reliable operation in heavy industrial applications, follow these physical routing and electrical termination practices:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Protection:\u003c\/strong\u003e Install the interconnect cable in a protective conduit or dedicated cable trays to guard against mechanical damage, cutting, or crushing in harsh environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Avoid routing the signal cable adjacent to high-voltage power lines or variable frequency drive (VFD) cables to prevent electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the cable shield is properly terminated at the monitoring system or local junction box terminal strip to maintain a single-point ground, preventing ground loop noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating Integrity:\u003c\/strong\u003e Ensure the 3-socket plug is fully threaded and seated onto the accelerometer connector. It is recommended to implement IP54 ingress protection or better at the mating point for outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566115691,"sku":"16925-12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16925-12-interconnect-cable-4aabcfcibnj_f0de65f3-23ff-4cdc-a633-744fcd38ce79.jpg?v=1765440740"},{"product_id":"bently-nevada-16710-66-330400-interconnect-cable","title":"Bently Nevada 16710-66 330400 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 66 (66.0 ft cable length) specifies this 3-conductor shielded armored cable configuration — \u003cstrong\u003e16710-66\u003c\/strong\u003e, which serves as an \u003cstrong\u003einterconnect cable\u003c\/strong\u003e designed for Bently Nevada 330400 and 330425 accelerometer transducers.\u003c\/p\u003e\n\u003cp\u003eThis cable configuration incorporates integrated metal armor over 22 AWG (0.5 mm2) conductors, shielding delicate accelerometer signals from physical impact, abrasion, and electromagnetic interference. It is equipped with a 3-socket plug on the transducer connection end and terminal lugs on the receiver end, supporting direct connection to industrial monitor panels or junction boxes.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength Option 66:\u003c\/strong\u003e Provides 66.0 ft (20.1 m) of run length to handle mid-to-long distance physical separation between the transducer and junction box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Metal Armor:\u003c\/strong\u003e Offers heavy-duty protection against abrasive materials, crushing force, and impact in critical industrial settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielded 22 AWG Core:\u003c\/strong\u003e Combines low-resistance copper conductors with overall shielding to isolate and preserve clean vibration signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMIL-C-5015 Socket End:\u003c\/strong\u003e Features a durable 3-socket plug termination to match the heavy-duty threads of standard casing sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Lug Ends:\u003c\/strong\u003e Prepared with terminal lugs on the receiver end for rapid and secure screw terminal connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCasing acceleration and vibration measurements on rotating machinery such as gearboxes, steam turbines, gas turbines, and pumps.\u003c\/li\u003e\n\u003cli\u003eInterconnecting Bently Nevada 330400 or 330425 accelerometers with 3500 series vibration monitoring systems or intermediate junction boxes.\u003c\/li\u003e\n\u003cli\u003eEnvironments where mechanical hazards require armored cabling to prevent physical damage to critical signal paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Code\u003c\/th\u003e\n\u003cth\u003eThis SKU Value\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16710\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded 22 AWG armored interconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003ctd\u003e66 ft (approx. 20.1 m) length (ordered in increments of 1.0 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16710-66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Core Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated metal armor outer layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector A (Sensor End)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-socket plug (mates with 3-pin MIL-C-5015)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector B (Monitor End)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 ft (approx. 20.1 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 ft (0.9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Accelerometers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 330400 and 330425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum System Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 305 m (1000 ft) with no signal degradation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the armored cable through protected environments or directly across mechanical supports where hazards exist. Avoid placing the cable near high-voltage lines or high electromagnetic sources to prevent signal interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Properly terminate the cable shield at the monitoring system or junction box terminal. Keep the shield isolated at the transducer end to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Bend Radius:\u003c\/strong\u003e Maintain the recommended bend radius of the metal armor during installation to prevent crimping the inner 22 AWG conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Assembly:\u003c\/strong\u003e Align and hand-tighten the 3-socket plug connector onto the MIL-C-5015 sensor receptacle, ensuring a snug and secure seal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e Environmental Protection Use Period (EFUP) designation of 15 years in accordance with SJ\/T 11364-2024.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666570441067,"sku":"16710-66","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-66-interconnect-cable-my0nqs1f4g0_86647a33-81bf-4c2d-91b8-cd77d30976ef.jpg?v=1765440828"},{"product_id":"bently-nevada-84661-99-standard-armored-interconnect-cable","title":"Bently Nevada 84661-99 Standard Armored Interconnect Cable","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e84661-99\u003c\/strong\u003e is a heavy-duty, industrial-grade \u003cstrong\u003estandard armored interconnect cable\u003c\/strong\u003e engineered to maintain safe, uninterrupted signal routes inside severe processing environments. This high-integrity hardware assembly links casing-mounted proximity sensors, accelerometers, or velocity transmitters directly to remote monitor racks, programmable logic controllers (PLCs), or distributed control systems (DCSs). To combat severe electrical noise, the \u003cstrong\u003e84661-99\u003c\/strong\u003e utilizes a 22 AWG twisted, shielded pair architecture wrapped inside a robust aluminum-polyester shielding tape with an integrated drain wire line.\u003c\/p\u003e\n\u003cp\u003eWhat distinguishes this specific variant is its outer layer of stainless steel armor shielding, which provides superior mechanical crush protection, cutting resistance, and physical guarding against abrasive structural contact or accidental pinch points. The assembly comes factory-terminated with a tight-fitting, 2-socket moisture-resistant molded female connector block with a threaded locking ring at one end to establish an airtight environmental seal on the sensor header, and raw bare wire ends on the opposing side for rapid terminal strip landing. The \u003cstrong\u003e-99\u003c\/strong\u003e suffix indicates a precise factory-cut length configuration of exactly 99 feet (approximately 30.1 meters), ensuring stable signal transmission over extended plant layouts without adding capacitive signal distortion.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel armored outer wrap providing excellent physical crush guarding and mechanical protection in harsh areas.\u003c\/li\u003e\n\u003cli\u003eHigh-density 2-conductor twisted, shielded pair configuration to block high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eFactory-molded moisture-resistant 2-socket female connector establishing a locked ambient seal at the transducer head.\u003c\/li\u003e\n\u003cli\u003eStripped bare wire trailing ends prepared for efficient termination inside local monitor panel terminal strips.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty 22 AWG high-conductivity copper core layout maximizing signal path transmission efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRouting critical casing velocity or vibration signals across exposed open-air industrial structural steel decks.\u003c\/li\u003e\n\u003cli\u003eInterfacing field-mounted vibration transmitters with remote control rooms in heavy-duty mining, oil, or refining operations.\u003c\/li\u003e\n\u003cli\u003eGeneral low-voltage instrumentation link integration across high-vibration balance-of-plant rotating machinery skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661 (Standard Armored Interconnect Cable Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Assembly Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-99 (Specified length of 99 feet \/ 30.18 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Twisted Shielded Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (Approximately 0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-conductor twisted pair with integrated drain wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull coverage aluminum-polyester shield line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Protection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel flexible protective armor wrap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-socket moisture-resistant molded female connector block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBare wire ends prepared for terminal strip landing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 300 V RMS operational insulation capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial performance envelope rated for high-thermal field exposures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 ft. (30.18 m) fixed option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStationary Minimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGenerous layout radius required due to flexible stainless steel armor wrap limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard armored field interconnect cable weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable End Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePhysical Interface Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Transducer Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded 2-socket female connector with integrated threaded locking ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Panel Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate bare wire channels for positive, negative, and shield drain lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmored Routing Routes:\u003c\/strong\u003e Secure the armored cable length along structural beams using heavy-duty cable clamps. While the steel armor prevents crush damage, avoid pulling it past sharp metal edges that could tear the outer jacket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Connection Sealing:\u003c\/strong\u003e Align the female terminal connector pins accurately onto the transducer plug. Hand-tighten the threaded coupling ring completely to verify a locked, moisture-resistant environmental barrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Compliance:\u003c\/strong\u003e Maintain generous layout bend loops at all enclosure entry joints. Avoid sharp crimps or tight physical kinks that could deform the stainless steel armor or split the internal core shielding layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Point Grounding:\u003c\/strong\u003e Connect the shield drain wire only at one designated common reference ground point—typically at the monitor panel terminal strip—to prevent creating performance-degrading ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666621821291,"sku":"84661-99","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-84661-99-standard-armored-interconnect-cable-bc1dfu0pzkg_c1ec598a-bbca-4e1c-8e7e-fb4cd2dbb9b1.jpg?v=1765444271"},{"product_id":"bently-nevada-9571-50-standard-interconnect-cable","title":"Bently Nevada 9571-50 Standard Interconnect Cable","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9571-50\u003c\/strong\u003e is a standard interconnect cable designed for use with industrial vibration monitoring and transducer systems. The cable assembly includes a moisture-resistant female connector at the transducer end and ring lugs at the monitor end for direct field wiring termination.\u003c\/p\u003e\n\u003cp\u003eThe cable uses shielded 0.382 mm2 (22 AWG) conductors to support stable signal transmission in electrically noisy industrial environments. The shielding construction assists with EMI\/RFI mitigation in machinery monitoring installations.\u003c\/p\u003e\n\u003cp\u003eThis interconnect cable is intended for connection between vibration transducers and monitoring equipment in rotating machinery applications including turbines, pumps, compressors, motors, and general condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe assembly supports installation in industrial environments requiring moisture resistance and extended operating temperature capability.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eShielded 0.382 mm2 (22 AWG) cable\u003c\/li\u003e\n\u003cli\u003eMoisture-resistant female connector\u003c\/li\u003e\n\u003cli\u003eRing lug termination at monitor end\u003c\/li\u003e\n\u003cli\u003eIndustrial transducer interconnect design\u003c\/li\u003e\n\u003cli\u003eEMI\/RFI shielding support\u003c\/li\u003e\n\u003cli\u003eFlexible field installation\u003c\/li\u003e\n\u003cli\u003eExtended temperature range\u003c\/li\u003e\n\u003cli\u003eCompatible with vibration monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVibration monitoring systems\u003c\/li\u003e\n\u003cli\u003eProximity transducer connections\u003c\/li\u003e\n\u003cli\u003eMachinery protection systems\u003c\/li\u003e\n\u003cli\u003eTurbine monitoring installations\u003c\/li\u003e\n\u003cli\u003eCompressor monitoring systems\u003c\/li\u003e\n\u003cli\u003eMotor condition monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating equipment\u003c\/li\u003e\n\u003cli\u003eProcess plant instrumentation\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance systems\u003c\/li\u003e\n\u003cli\u003ePermanent mounted monitoring installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e9571-AA: Standard Interconnect Cable\u003c\/li\u003e\n\u003cli\u003e-50: 50 ft (15.2 m) cable length option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eElectricalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eShielded cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eConductor Size\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eEnvironmentalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-29 to 121 degC (-20 to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMoisture Resistance\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eMoisture-resistant connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eMechanicalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eFemale connector at transducer end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMonitor End Termination\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eMinimum Length\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e2 ft (0.60 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMaximum Length\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eGeneralSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eStandard Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eTransducer Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eConnections\/Interfaces\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eConnector PinFunction\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eFemale Connector\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eTransducer connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eRing Lugs\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eMonitor termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cp\u003eRoute the cable separately from high-voltage motor wiring and variable frequency drive output cables to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eMaintain cable shielding continuity throughout the installation to support signal integrity.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive cable bending near the connector termination points during installation.\u003c\/p\u003e\n\u003cp\u003eSecure the cable properly to minimize vibration-related mechanical stress.\u003c\/p\u003e\n\u003cp\u003eVerify ring lug tightening torque during monitor termination work.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing surfaces before installation in moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eUse appropriate cable routing practices to prevent abrasion or pinch damage.\u003c\/p\u003e\n\u003cp\u003eAvoid extending the cable beyond the specified maximum length.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the conductor size of this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable uses 0.382 mm2 (22 AWG) conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of shielding is provided?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe assembly uses shielded cable construction for industrial signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat connector is installed at the transducer end?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA moisture-resistant female connector is installed at the transducer end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the monitor end terminated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor end uses ring lug terminations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum supported cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum specified length is 99 ft (30 m).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum available cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe minimum specified length is 2 ft (0.60 m).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the cable be used in industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The cable is intended for industrial vibration monitoring installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the cable support EMI\/RFI mitigation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shielded construction assists with EMI\/RFI reduction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat systems is the cable intended for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is intended for transducer and vibration monitoring system connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the cable be used outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe connector is moisture resistant, but installation suitability depends on enclosure and site conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat temperature range is supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified operating range is -29 to 121 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable suitable for permanent installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is suitable for permanently mounted machinery monitoring systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666624344427,"sku":"9571-50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-50-standard-interconnect-cable-tfd2n403jen_f9932837-544b-41d4-9e0b-edfee3645b51.jpg?v=1765444312"},{"product_id":"bently-nevada-84661-90-standard-armored-interconnect-cable","title":"Bently Nevada 84661-90 Standard Armored Interconnect Cable","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e84661-90\u003c\/strong\u003e is a heavy-duty, industrial-grade \u003cstrong\u003estandard armored interconnect cable\u003c\/strong\u003e engineered to maintain safe, uninterrupted signal routes inside severe processing environments. This high-integrity hardware assembly links casing-mounted proximity sensors, accelerometers, or velocity transmitters directly to remote monitor racks, programmable logic controllers (PLCs), or distributed control systems (DCSs). To combat severe electrical noise, the \u003cstrong\u003e84661-90\u003c\/strong\u003e utilizes a 22 AWG twisted, shielded pair architecture wrapped inside a robust aluminum-polyester shielding tape with an integrated drain wire line.\u003c\/p\u003e\n\u003cp\u003eWhat distinguishes this specific variant is its outer layer of stainless steel armor shielding, which provides superior mechanical crush protection, cutting resistance, and physical guarding against abrasive structural contact or accidental pinch points. The assembly comes factory-terminated with a tight-fitting, 2-socket moisture-resistant molded female connector block with a threaded locking ring at one end to establish an airtight environmental seal on the sensor header, and raw bare wire ends on the opposing side for rapid terminal strip landing. The \u003cstrong\u003e-90\u003c\/strong\u003e suffix indicates a precise factory-cut length configuration of exactly 90 feet (approximately 27.4 meters), ensuring stable signal transmission over extended plant layouts without adding capacitive signal distortion.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel armored outer wrap providing excellent physical crush guarding and mechanical protection in harsh areas.\u003c\/li\u003e\n\u003cli\u003eHigh-density 2-conductor twisted, shielded pair configuration to block high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eFactory-molded moisture-resistant 2-socket female connector establishing a locked ambient seal at the transducer head.\u003c\/li\u003e\n\u003cli\u003eStripped bare wire trailing ends prepared for efficient termination inside local monitor panel terminal strips.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty 22 AWG high-conductivity copper core layout maximizing signal path transmission efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRouting critical casing velocity or vibration signals across exposed open-air industrial structural steel decks.\u003c\/li\u003e\n\u003cli\u003eInterfacing field-mounted vibration transmitters with remote control rooms in heavy-duty mining, oil, or refining operations.\u003c\/li\u003e\n\u003cli\u003eGeneral low-voltage instrumentation link integration across high-vibration balance-of-plant rotating machinery skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661 (Standard Armored Interconnect Cable Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Assembly Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-90 (Specified length of 90 feet \/ 27.43 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Twisted Shielded Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (Approximately 0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-conductor twisted pair with integrated drain wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull coverage aluminum-polyester shield line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Protection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel flexible protective armor wrap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-socket moisture-resistant molded female connector block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBare wire ends prepared for terminal strip landing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 300 V RMS operational insulation capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial performance envelope rated for high-thermal field exposures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 ft. (27.43 m) fixed option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStationary Minimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGenerous layout radius required due to flexible stainless steel armor wrap limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard armored field interconnect cable weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable End Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePhysical Interface Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Transducer Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded 2-socket female connector with integrated threaded locking ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Panel Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate bare wire channels for positive, negative, and shield drain lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmored Routing Routes:\u003c\/strong\u003e Secure the armored cable length along structural beams using heavy-duty cable clamps. While the steel armor prevents crush damage, avoid pulling it past sharp metal edges that could tear the outer jacket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Connection Sealing:\u003c\/strong\u003e Align the female terminal connector pins accurately onto the transducer plug. Hand-tighten the threaded coupling ring completely to verify a locked, moisture-resistant environmental barrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Compliance:\u003c\/strong\u003e Maintain generous layout bend loops at all enclosure entry joints. Avoid sharp crimps or tight physical kinks that could deform the stainless steel armor or split the internal core shielding layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Point Grounding:\u003c\/strong\u003e Connect the shield drain wire only at one designated common reference ground point—typically at the monitor panel terminal strip—to prevent creating performance-degrading ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666640892267,"sku":"84661-90","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-84661-90-standard-armored-interconnect-cable-40ezb5jsn1f_a49a05ed-2775-42da-8c1f-3caa564a7c72.jpg?v=1765444548"},{"product_id":"bently-nevada-106765-07-330525-velomitor-xa-interconnect-cable","title":"Bently Nevada 106765-07 330525 Velomitor XA Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e106765-07\u003c\/strong\u003e is a 7.0-meter \u003cstrong\u003einterconnect cable\u003c\/strong\u003e assembly designed to connect a 330525 Velomitor XA Piezo-velocity Sensor to a terminal housing or monitor. This configuration is specified by Option 07, designating a 7.0-meter (23.0 ft) length armored cable equipped with an integrated splash-resistant fluorosilicone boot cover and stainless steel armor.\u003c\/p\u003e\n\u003cp\u003eThis assembly uses a 2-conductor, twisted, shielded 0.382 sq mm (22 AWG) cable core enclosed within a protective stainless steel armor. The sensor connection end features a specialized, blue fluorosilicone boot with top and bottom securing clamps that seal against the Mil-C-26482 connector to meet IP-65 and NEMA 4X moisture-exclusion standards. The terminal end consists of stripped flying leads labeled A (white), B (black), and SHLD (green) protected by clear shrink tubing for secure termination.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 7.0 meters (23.0 ft) overall length with a tolerance of plus\/minus 200 mm (7.8 in).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Armor:\u003c\/strong\u003e Stainless steel armor wrapping protects the internal conductors from harsh industrial environments, mechanical impact, and abrasion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeatherproof Connection:\u003c\/strong\u003e Blue fluorosilicone elastomer splash-resistant boot cover with top and bottom stainless steel securing clamps ensures an IP-65 and NEMA 4X rating at the sensor interface.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCore Wire Construction:\u003c\/strong\u003e 2-conductor twisted, shielded 0.382 sq mm (22 AWG) core wire optimizing signal transmission and noise immunity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlying Leads:\u003c\/strong\u003e Pre-stripped wires with clear shrink tubing labeled white (A), black (B), and green (SHLD) for straightforward terminal block installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 106765-07 interconnect cable is designed for harsh-environment rotating machinery protection and monitoring. Typical industries and applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Steam turbines, gas turbines, and cooling tower fans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil and Gas \/ Petrochemical:\u003c\/strong\u003e Centrifugal compressors, pumps, and expanders operating in wet or corrosive conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Treatment:\u003c\/strong\u003e High-moisture areas where NEMA 4X and IP-65 sealing are mandatory.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy Industry:\u003c\/strong\u003e Mining and cement plant machinery subject to extreme mechanical abrasion where armored cables are critical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis product is an orderable configuration of the Bently Nevada 106765 series interconnect cable. The part number breakdown is detailed below:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e106765-07\u003c\/td\u003e\n      \u003ctd\u003eVelomitor XA Interconnect Cable with Stainless Steel Armor and Splash-Resistant Boot\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOption A - Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e07\u003c\/td\u003e\n      \u003ctd\u003e7.0 meters (23.0 feet) overall length\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e106765-07\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2-conductor twisted, shielded interconnect cable with mechanical armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.382 sq mm (22 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBoot Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBlue fluorosilicone elastomer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Connector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2-pin Mil-C-26482 style with weatherproof boot cover\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Termination\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFlying leads: white (A), black (B), green (SHLD) with clear shrink tubing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.0 m (23.0 ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLength Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eplus\/minus 200 mm (7.8 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e38 mm (1.5 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMeets IP-65 and NEMA 4X standards when properly installed on the 330525 sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-55 degC to +121 degC (-67 degF to +250 degF) matching sensor specifications\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe 106765-07 cable maps the 2-pin Mil-C-26482 sensor connector pins to specific wire colors at the terminal termination end:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eMil-C-26482 Connector Pin\u003c\/th\u003e\n      \u003cth\u003eWire Color\u003c\/th\u003e\n      \u003cth\u003eSignal Function\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin A\u003c\/td\u003e\n      \u003ctd\u003eWhite\u003c\/td\u003e\n      \u003ctd\u003eSignal \/ Positive (+)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin B\u003c\/td\u003e\n      \u003ctd\u003eBlack\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Negative (-)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShield (Case)\u003c\/td\u003e\n      \u003ctd\u003eGreen\u003c\/td\u003e\n      \u003ctd\u003eSHLD \/ Instrument Ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure correct implementation by adhering to standard field practices for industrial vibration sensors:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRouting:\u003c\/strong\u003e Route the armored cable through dedicated cable trays or conduit where possible to prevent accidental physical damage or pulling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain the minimum 38 mm (1.5 in) bend radius during routing and permanent clamping to prevent fatigue of internal 22 AWG conductors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the green SHLD lead to the designated instrument ground at the monitor or terminal block end. Do not ground both ends of the shield to avoid ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeatherproofing:\u003c\/strong\u003e Verify that the top and bottom clamps of the blue fluorosilicone boot are fully seated and tightened around the sensor body and cable armor to maintain IP-65\/NEMA 4X moisture sealing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis cable is a passive mechanical accessory designed for use with Bently Nevada hazardous area certified vibration transmitters and monitors, complying with the following systems:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Approvals:\u003c\/strong\u003e Certified for use in hazardous areas when paired with the 330525 Velomitor XA sensor under CSA, NRTL\/C, ATEX, and IECEx approvals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU RoHS directives.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666642760043,"sku":"106765-07","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-106765-07-interconnect-cable-o200hrahq3v_72ce91e9-429d-4c57-a6c9-a4c07444f9dd.jpg?v=1765444573"},{"product_id":"bently-nevada-89477-25-standard-armored-interconnect-cable","title":"Bently Nevada 89477-25 стандартен брониран свързващ кабел","description":"\u003ch3\u003eОписание\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 89477-25\u003c\/strong\u003e е здрав \u003cstrong\u003eстандартен брониран междинен кабел\u003c\/strong\u003e, проектиран специално за защита на критично оборудване и системи за мониторинг на състоянието. Създаден с издръжлив конектор под прав ъгъл, този кабел осигурява надеждна предаване на сигнала между близостни сензори, датчици и модули за мониторинг в рамките на \u003cstrong\u003eBently Nevada Proximitor Sensor Systems\u003c\/strong\u003e. Интегрираната бронирана обвивка гарантира здрава механична защита срещу физически повреди, износване и екологични рискове, характерни за взискателни индустриални среди. Чрез осигуряване на прецизна, с ниско затихване доставка на сигнала, той поддържа точни измервания на вибрации, позиция и скорост за високоскоростни въртящи се машини.\u003c\/p\u003e\n\u003ch3\u003eХарактеристики\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eКонфигурация на конектора под прав ъгъл за нископрофилна инсталация в ограничени пространства\u003c\/li\u003e\n\u003cli\u003eИнтегрирана стандартна бронирана обвивка за превъзходна механична и екологична защита\u003c\/li\u003e\n\u003cli\u003eПредварително изрязана дължина, оптимизирана за поддържане на целостта на сигнала и точността на калибриране\u003c\/li\u003e\n\u003cli\u003eЗдрава конструкция, устойчива на индустриални течности, масла и физически натоварвания\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eПриложения\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eСистеми за мониторинг на вибрациите на парни и газови турбини\u003c\/li\u003e\n\u003cli\u003eДиагностика на центробежни и бутални компресори\u003c\/li\u003e\n\u003cli\u003eИзмерване на отклонения на валове на големи индустриални помпи, вентилатори и електрически двигатели\u003c\/li\u003e\n\u003cli\u003eНастройки за измерване на въздушната междина и вибрациите на хидроелектрически генератори\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eТехнически спецификации\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eПараметър\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eСпецификация\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eПроизводител\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eМодел\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eТип кабел\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eСтандартен брониран междинен кабел\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eОриентация на конектора\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eПрав ъгъл\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eДължина на кабела\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 фута (приблизително 7.6 метра)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eДържава на произход\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eСъединени щати\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eТегло\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.15 кг (приблизително, базирано на стандартната броня)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eРазмери\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eОбща дължина 7.6 метра\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eИнструкции за монтаж\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eПоддържане на радиус на огъване\u003c\/strong\u003e: Избягвайте огъване на бронираната част извън минималния посочен радиус, за да предотвратите повреди на вътрешните проводници и бронята.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eМаршрутизиране на конектора\u003c\/strong\u003e: Уверете се, че конекторът под прав ъгъл е правилно ориентиран преди затягане, за да се избегне структурно напрежение в точката на свързване на сензора.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eМаршрутизиране на кабела\u003c\/strong\u003e: Прекарайте междинния кабел далеч от високоволтови тръбопроводи, устройства с променлива честота (VFD) и линии с променлив ток (AC), за да минимизирате електромагнитните смущения (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eЗащита от влага\u003c\/strong\u003e: Уверете се, че всички интерфейси за свързване са чисти, сухи и правилно запечатани по време на монтажа, за да се избегне проникване на влага и влошаване на сигнала.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eЧесто задавани въпроси\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eКаква е целта на конектора под прав ъгъл на този кабел?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eДизайнът под прав ъгъл позволява сигурни връзки в ограничени пространства, където правите конектори биха претърпели прекомерно механично напрежение или проблеми с пространството.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eМоже ли този кабел да се използва с всяка система за близостни сензори?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eТой е специално проектиран да се интегрира със съвместими системи за близостни сензори и Proximitor на Bently Nevada, които отговарят на изискванията за свързване.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eПредпазва ли бронята от химическо въздействие?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eСтандартната броня осигурява отлична механична защита срещу физически удари и износване, като също така предлага устойчивост на обичайни индустриални масла и влага при стандартни работни условия.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666733461867,"sku":"89477-25","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-89477-25-interconnect-cable-zyyj4ofhkb0_ee5e8dba-aa63-42b7-a111-1d4ccb7e7d30.jpg?v=1765446724"},{"product_id":"bently-nevada-9571-30-interconnect-cable","title":"Bently Nevada 9571-30 Standard Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9571-30\u003c\/strong\u003e is a heavy-duty, shielded \u003cstrong\u003einterconnect cable\u003c\/strong\u003e designed for critical machinery protection and vibration monitoring systems. It establishes a reliable signal transmission pathway between High Temperature Velocity Sensors (HTVS) and monitoring systems, ensuring the integrity of dynamic vibration data in harsh industrial environments. The cable features advanced shielding to minimize electromagnetic interference and a moisture-resistant termination to maintain electrical performance under demanding conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated moisture-resistant female connector at the HTVS termination point\u003c\/li\u003e\n\u003cli\u003ePre-terminated ring lugs at the monitor end for secure terminal block installation\u003c\/li\u003e\n\u003cli\u003eRobust shielding to protect low-level signals from EMI and RFI noise\u003c\/li\u003e\n\u003cli\u003eWide operating temperature rating for deployment in extreme industrial climates\u003c\/li\u003e\n\u003cli\u003eFlexible 22 AWG conductors optimizing signal conductivity and mechanical durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring\u003c\/li\u003e\n\u003cli\u003ePower generation facility machinery protection\u003c\/li\u003e\n\u003cli\u003ePetrochemical plant rotating equipment diagnostics\u003c\/li\u003e\n\u003cli\u003eHigh-temperature industrial fan and blower monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9571-AA\u003c\/td\u003e\n\u003ctd\u003eStandard Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-30\u003c\/td\u003e\n\u003ctd\u003e30 Feet = 9.0 Metres (approx.) length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9571-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eStandard Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eShielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type A (HTVS End)\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type B (Monitor End)\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 degC (-20 to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e30 Feet (approx. 9.0 Metres)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eAvailable upon request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e30 Feet length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection:\u003c\/strong\u003e Ensure the moisture-resistant female connector is fully seated and sealed at the HTVS end to prevent water ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the cable through dedicated conduit or cable trays away from high-voltage AC power lines to mitigate EMI\/RFI noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain the minimum recommended bend radius during installation to prevent damage to the internal 22 AWG conductors and shielding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Connect the cable shield in accordance with the specific monitoring system diagram, typically grounding at the monitor end only to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connections:\u003c\/strong\u003e Secure the pre-terminated ring lugs firmly to the monitor terminal blocks to ensure a vibration-proof electrical connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of sensor connects to the 9571-30 cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is specifically configured to interface with High Temperature Velocity Sensors (HTVS) on one end and standard machinery monitoring systems on the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this interconnect cable withstand outdoor industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the cable construction incorporates a moisture-resistant female connector and a rugged outer jacket rated for temperatures up to 121 degC, making it suitable for demanding industrial deployments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the shield terminated on this specific cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor end is fitted with ring lugs which accommodate standard grounding practices on monitor terminal strips, while the sensor end features a specialized shielded interface within the female connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to obtain this cable in lengths other than 30 feet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNon-standard and custom lengths can be ordered from the manufacturer using the 9571-AA configuration logic at additional cost.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666733691243,"sku":"9571-30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-30-interconnect-cable-yfe2hoqlxvu_60641b4b-4792-470b-853b-c190d2b0a9ca.jpg?v=1765446728"},{"product_id":"bently-nevada-89477-30-interconnect-cable","title":"Bently Nevada 89477-30 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e89477-30\u003c\/strong\u003e is a heavy-duty, industrial-grade \u003cstrong\u003estandard interconnect cable\u003c\/strong\u003e engineered to maintain high-integrity signal routes inside machine monitoring environments. This specialized electrical link is designed to transmit critical, raw velocity waveforms and high-frequency acceleration variables from casing-mounted sensors or field transmitters straight to centralized monitor frameworks, programmable logic controllers (PLCs), or distributed control systems (DCSs). The \u003cstrong\u003e89477-30\u003c\/strong\u003e utilizes a twisted, shielded pair architecture wrapped in a robust, chemically stable outer insulation jacket to deliver excellent mitigation against high-frequency electromagnetic interference (EMI) and radio frequency interference (RFI) common around heavy industrial machinery arrays.\u003c\/p\u003e\n\u003cp\u003eThe assembly comes factory-terminated with a tight-fitting, weather-resistant molded female connector block at one end to establish a secure environmental seal on the sensor header, and raw bare wire terminal ends on the opposing side for quick landing onto local panel terminal strips. The \u003cstrong\u003e-30\u003c\/strong\u003e suffix indicates a precise factory-cut length configuration of exactly 30 feet (approximately 9.1 meters). Built to operate continuously under wide temperature variations, it ensures highly reliable data delivery for critical rotating assets without adding signal distortion or capacitive loss.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density twisted, shielded pair wire configuration to block aggressive industrial electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eFactory-molded moisture-resistant female terminal connector establishing a reliable ambient seal at the transducer head.\u003c\/li\u003e\n\u003cli\u003eStripped bare wire trailing ends for efficient termination inside local junction boxes or machine monitoring racks.\u003c\/li\u003e\n\u003cli\u003eTough, corrosion-resistant outer insulation layer designed to withstand oil splash and physical friction forces.\u003c\/li\u003e\n\u003cli\u003eOptimized electrical parameters preventing capacitive signal attenuation across extended structural measurement spans.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfacing casing-mounted piezo-velocity sensors or accelerometers with remote monitoring racks.\u003c\/li\u003e\n\u003cli\u003eRouting dynamic diagnostic asset protection signals from hazardous field areas to safe control rooms.\u003c\/li\u003e\n\u003cli\u003eGeneral low-voltage instrumentation link integration across high-vibration balance-of-plant rotating machinery skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477 (Standard Interconnect Cable Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Assembly Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 (Specified length of 30 feet \/ 9.14 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Twisted Shielded Interconnect Cable Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Wire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial instrumentation gauge layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwisted pair with integrated shield drain wire line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-coverage aluminum-polyester or equivalent braid shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded moisture-resistant female socket connector block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBare wire ends prepared for terminal strip landing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Jacket Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRuggedized chemical and wear-resistant polymer outer sheath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial performance envelope rated for high-thermal field exposures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ft. (9.14 m) fixed option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Installation Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible routing layout design compatible with standard conduit bends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard field interconnect cable weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable End Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePhysical Interface Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Transducer Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded female terminal connector with integrated threaded locking ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Panel Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate bare wire channels for positive, negative, and shield drain lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Path Planning:\u003c\/strong\u003e Route the interconnect cable through dedicated low-voltage instrument conduits. Keep the signal run isolated from parallel high-voltage motor supply lines to minimize capacitive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Connection Sealing:\u003c\/strong\u003e Align the female terminal connector pins accurately onto the transducer plug. Hand-tighten the threaded coupling ring completely to verify a locked, moisture-resistant environmental barrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Compliance:\u003c\/strong\u003e Maintain generous layout bend loops at all enclosure entry joints. Avoid sharp crimps or tight physical kinks that could break the internal core layout or split the shielding layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Point Grounding:\u003c\/strong\u003e Connect the shield drain wire only at one designated common reference ground point—typically at the monitor panel terminal strip—to prevent creating performance-degrading ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666735427947,"sku":"89477-30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-89477-30-interconnect-cable-bam1fedghr3_b914bd85-71f7-4d98-862c-742ab51d7f4b.jpg?v=1765446779"},{"product_id":"bently-nevada-9571-33-standard-interconnect-cable","title":"Стандартен свързващ кабел Bently Nevada 9571-33","description":"\u003ch3\u003eОписание\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 9571-33\u003c\/strong\u003e е здрав, екранован междинен кабелен комплект, предназначен за пренос на оперативни измервания между трансдюсери на машини и централни мониторингови системи. Този специализиран свързващ елемент разполага с 33-футова (10-метрова) предварително изрязана измервателна дължина, изградена с вътрешни проводници 0.382 мм2 (22 AWG). За да се запази целостта на полевата верига в мокри или агресивни неклиматизирани работни условия, комплектът е оборудван с фабрично формован влагозащитен женски конектор на интерфейса на трансдюсера, комбиниран със здрави пръстеновидни накрайници на страната на монитора. Той осигурява стабилна електрическа защита за намаляване на смущенията от високочестотни земни вериги, подпомагайки поддържането на безупречна работа на мониторинговата инфраструктура в широк индустриален температурен диапазон.\u003c\/p\u003e\n\u003ch3\u003eХарактеристики\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eИзработен с издръжливи вътрешни 0.382 мм2 (22 AWG) екрановани кабелни пътища.\u003c\/li\u003e\n\u003cli\u003eЗавършен на фабриката с влагозащитен женски щепсел на полевия трансдюсер.\u003c\/li\u003e\n\u003cli\u003eПредварително оборудван с индустриални пръстеновидни накрайници на клемния край на контролния корпус.\u003c\/li\u003e\n\u003cli\u003eПроектиран да запази пътищата на сигналите от агресивни външни електрически емисии.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eПриложения\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eВисококачествено динамично маршрутизиране на сигнали от полеви трансдюсери към централни системи за защита на машини.\u003c\/li\u003e\n\u003cli\u003eТежки неклиматизирани производствени зони, изискващи специализирани влагозащитени свързващи кабели.\u003c\/li\u003e\n\u003cli\u003eИндустриални въртящи се машини, изискващи непрекъсната интеграция на сензорни сигнали с нисък шум.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eТехнически спецификации\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eПараметър\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eСпецификация\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eПроизводител\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eМоделен код\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571-33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eТип продукт\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eСтандартен междинен кабел\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eДължина на кабела\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 фута (10 м)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eСечение на проводника\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.382 мм2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eТип кабелна конструкция\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eЕкранован\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eИнтерфейс за свързване на трансдюсера\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eВлагозащитен женски конектор\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eИнтерфейс за свързване на монитора\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eПръстеновидни накрайници\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eРаботен температурен диапазон\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 до 121 °C (-20 до 250 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eВръзки\/Интерфейси\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eПозиция на конектора\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eТип интерфейс за свързване\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eКрай на трансдюсера\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eВлагозащитен женски конектор\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eКрай на монитора\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eПръстеновидни накрайници\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eИнструкции за монтаж\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eРазположете 33-футовия кабел по предназначените индустриални кабелни лоткове, като държите целия път свободен от зони с екстремно физическо притискане или ръбове с високо триене.\u003c\/li\u003e\n\u003cli\u003eПодравнете и свържете влагозащитения женски терминал напълно върху масивата от щифтове на резбата на трансдюсера, докато се постигне уплътнение за околната среда.\u003c\/li\u003e\n\u003cli\u003eЗатегнете здраво терминалите с пръстеновидни накрайници към клемите на мониторинговия корпус, като осигурите достатъчно напрежение на винтовете, за да предотвратите прекъсвания на вибрационната верига.\u003c\/li\u003e\n\u003cli\u003eОтделете траекторията на комуникация на сензора от високоволтовите първични захранващи линии на мотора, за да предотвратите свързване на шум от полето или преходни смущения в сигнала.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666738770283,"sku":"9571-33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-33-standard-interconnect-cables-meln5eur4dq_f7e56018-c06e-47c1-bf54-d278a1e96224.jpg?v=1765446854"},{"product_id":"bently-nevada-16710-33-interconnect-cable-with-armor","title":"Bently Nevada 16710-33 Interconnect Cable with Armor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-33\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterconnect cable with armor from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis designed for secure signal transmission in machinery protection and vibration monitoring systems operating in harsh industrial environments. It is widely deployed in turbines, compressors, pumps, generators, and large rotating equipment installed in refinery, petrochemical, offshore, and power generation facilities where mechanical stress, oil exposure, and continuous vibration are present.\u003c\/p\u003e\n\u003cp\u003eThis armored interconnect cable provides reinforced mechanical protection for signal wiring used between proximity probes, proximitor modules, junction boxes, and monitoring systems. The 33 ft length supports flexible installation in medium-range equipment layouts while maintaining stable signal integrity in electrically noisy environments. The armored construction reduces the risk of abrasion, crushing, and mechanical fatigue, ensuring long service life in demanding industrial installations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 16710 series uses an armored cable structure designed to improve mechanical durability and environmental resistance in field installations.\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e16710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength Option\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial protective armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eInterconnect signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery protection systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Environment\u003c\/td\u003e\n\u003ctd\u003eHigh vibration, oil exposure, industrial plants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe armored layer provides mechanical shielding against external impact and cable wear, making it suitable for routing in areas with moving machinery, sharp structural edges, and high vibration loads. It is engineered to maintain consistent electrical performance while reducing signal degradation caused by mechanical stress.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16710-33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable with Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C (typical industrial cable range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring and machinery protection systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main purpose of armored construction in this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe armor provides mechanical protection against abrasion, crushing, and external impact in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the 16710-33 cable typically used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is used in machinery monitoring systems connecting probes, modules, and junction boxes in rotating equipment installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high vibration areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The armored design is specifically intended for high vibration industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable electrically active?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. It is a passive interconnect cable used for signal transmission only.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Engineering Recommendations\u003c\/h3\u003e\n\u003cp\u003eInstall the cable with proper strain relief to prevent mechanical stress transfer into connector termination points.\u003c\/p\u003e\n\u003cp\u003eAvoid routing near high-voltage power cables or VFD output lines to reduce electromagnetic interference in signal transmission.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius during installation to preserve conductor integrity under continuous vibration conditions.\u003c\/p\u003e\n\u003cp\u003eSecure armored sections using industrial cable clamps to ensure stable positioning in moving or high-vibration machinery areas.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666760528235,"sku":"16710-33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-33-interconnect-cable-3s1vfoeywic_fb947b41-3b19-4835-8272-260ec1e3ba41.jpg?v=1765447126"},{"product_id":"bently-nevada-9571-10-two-conductor-twisted-shielded-interconnect-cable","title":"Bently Nevada 9571-10 Two-Conductor Twisted Shielded Interconnect Cable","description":"\u003cp\u003eThe \u003cstrong\u003e9571\u003c\/strong\u003e instrumentation interconnect cable, complete part number \u003cstrong\u003e9571-10\u003c\/strong\u003e, is a high-performance two-conductor 22 AWG shielded cable assembly designed for transmitting dynamic vibration signals within machinery protection systems. The physical construction features a moisture-resistant two-socket female connector at the sensor termination end to maintain electrical insulation in humid environments, while the monitor termination end is fitted with standard terminal lugs for robust installation into I\/O chassis backplanes. This 10 ft (3.05 m) twisted-pair configuration provides superior differential noise rejection, ensuring precise signal transmission from compatible transducers directly to Bently Nevada machinery monitors. This cable is explicitly not designed for integration within the 21128 Velocity Transducer Housing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10: Cable Length Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e10 ft (3.05 m) nominal cable length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwisted, shielded pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-socket moisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.05 m (10 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 m (2.0 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 m (99 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Constraints\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot for use with 21128 Velocity Transducer Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 22 AWG twisted-pair geometry provides high noise immunity against electro-magnetic interference by canceling out differential-mode noise along the signal pathway.\u003c\/li\u003e\n\u003cli\u003eThe sensor-end termination utilizes a specialized moisture-resistant compound within the 2-socket female connector housing to prevent moisture ingress from degrading insulation resistance.\u003c\/li\u003e\n\u003cli\u003eTotal loop resistance and cable capacitance scale linearly with length; ensure overall parameters align with monitoring system input barriers to maintain accurate high-frequency data transfer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the cable shield drain wire exclusively to the instrument rack instrumentation ground bar, and completely isolate the shield at the transducer end to prevent structural ground loops.\u003c\/li\u003e\n\u003cli\u003eRoute the signal cable away from high-voltage AC electric motor supply cables, variable frequency drives (VFDs), and heavy inductive switching elements to maintain raw signal integrity.\u003c\/li\u003e\n\u003cli\u003eAdhere strictly to industrial minimum bending radius standards during conduit routing to prevent physical degradation of the internal shield foil and 22 AWG copper strands.\u003c\/li\u003e\n\u003cli\u003eEnsure the moisture-resistant connector is fully locked and sealed against the sensor body to guarantee long-term environmental protection and reliable contact interface.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666765181291,"sku":"9571-10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-10-interconnect-cable-xuptdzcpsz4_41f1678f-55d2-4cbd-834c-67e79130ed61.jpg?v=1765447211"},{"product_id":"bently-nevada-84661-82-standard-armored-interconnect-cable","title":"Bently Nevada 84661-82 Standard Armored Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 84661-82\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003eStandard Armored Interconnect Cable\u003c\/strong\u003e designed for critical signal transmission in industrial machinery protection and vibration monitoring systems. It features a rugged stainless steel armor wrapped over a shielded 0.382 mm2 (22 AWG) conductor core, providing excellent mechanical protection against physical damage and environmental hazards. The assembly is built with a moisture-resistant female connector at the High Temperature Velocity Sensor (HTVS) end and ring lugs at the monitor terminal end, ensuring secure, low-loss connectivity to continuous monitoring modules. Engineered to operate reliably across a temperature range of -29 to 121 Celsius, this cable is highly optimized for deployment with high-reliability sensors in harsh industrial monitoring environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel outer armoring for superior crush and abrasion resistance\u003c\/li\u003e\n\u003cli\u003eMoisture-resistant female terminal connector configured for HTVS applications\u003c\/li\u003e\n\u003cli\u003ePre-terminated ring lugs at the monitor interface for secure terminal block connection\u003c\/li\u003e\n\u003cli\u003eShielded 22 AWG core construction to minimize electrical noise and signal attenuation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring loops\u003c\/li\u003e\n\u003cli\u003eIndustrial compressor and expander casing velocity measurements\u003c\/li\u003e\n\u003cli\u003eHeavy-duty pump and fan vibration telemetry\u003c\/li\u003e\n\u003cli\u003eHigh-temperature processing areas requiring ruggedized physical cable shielding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.382 mm2 (22 AWG), shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor End Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector (HTVS end)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 Celsius (-20 to 250 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 Feet (approx. 24.6 Metres)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Ensure the shield drain wire or shielded component is correctly referenced to the designated monitor ground terminal to prevent ground loops and mitigate EMI\/RFI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Constraints\u003c\/strong\u003e: Do not force sharp bends or kinks in the stainless steel armoring during routing, as this can pinch internal conductors and rupture the protective shield.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection\u003c\/strong\u003e: Verify that the moisture-resistant female connector interface is fully seated and properly sealed at the HTVS end to prevent fluid ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Keep the path of the interconnect cable separate from high-voltage motor lines or switching control wires to protect the accuracy of low-level analog signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat sensor types link with this specific cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable is constructed with a moisture-resistant female terminal configuration explicitly intended for connection to High Temperature Velocity Sensors (HTVS) on the machine end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the monitor end interface connect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor end uses pre-installed ring lugs, which allow for a secure, bolt-down termination onto standard terminal blocks inside monitor enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the armored jacket withstand high-temperature processing zones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the components of this assembly are rated to sustain continuous exposure to industrial environments with ambient operational temperatures ranging from -29 to 121 Celsius.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666768195947,"sku":"84661-82","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-84661-82-velomitor-interconnect-cable-ohizj0hpw1b_1972d5ed-07ac-44bf-b813-1668d8ec3403.jpg?v=1765447242"},{"product_id":"bently-nevada-cb2w100-064-interconnect-cable","title":"Кабел за свързване Bently Nevada CB2W100-064","description":"\u003ch3\u003eТехническо резюме\u003c\/h3\u003e\n\u003cp\u003eBently Nevada CB2W100-064 е междусистемен кабел с дължина 64 фута (19,5 метра), проектиран за предаване на динамични вибрационни и ускорителни сигнали в системи за защита на машини. Той осигурява сигурен, с нисък шум сигнален път между индустриални трансдюсери и основни мониторингови системи, минимизирайки електромагнитните смущения (EMI) и предотвратявайки загуба на сигнал или фалшиви сработвания. Кабелът използва архитектура с усукана двойка и специален щит за поддържане на целостта на сигнала при дълги разстояния в сурови електромагнитни среди.\u003c\/p\u003e\n\u003ch3\u003eТехническа конфигурация\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB2W100\u003c\/strong\u003e: Обозначение на продуктовата серия за висококачествени, високотемпературни междусистемни кабели за динамични сигнали.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-064\u003c\/strong\u003e: Определя точната физическа дължина на кабелния комплект, зададена като 64 фута (еквивалентно на 19,5 метра).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eКонектори\u003c\/strong\u003e: Разполага със стандартен MIL-C 5015 2-гнезден конектор в сензорния край с изолация против пръски, преминаващ към изрязано на равно окончание в края за монитор\/разклонителна кутия.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eПроводници\u003c\/strong\u003e: Усукани двойки медни проводници 20 AWG, оптимизирани за ниско електрическо съпротивление и висока якост на опън.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eЩит\u003c\/strong\u003e: Вграден плетен или фолиен щит, осигуряващ непрекъснато покритие срещу радиочестотен и електростатичен шум.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eМатериал на обвивката\u003c\/strong\u003e: Високодурабилна жълта тефлонова (FEP) изолация, предлагаща превъзходна химическа устойчивост и термична стабилност.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eТехнически спецификации\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eПараметър\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eСпецификация\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eМодел\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCB2W100-064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eМарка\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eПроизход\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eСъединени щати\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eТегло\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e2,0 кг\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eДължина на кабела\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e64 фута (19,5 метра)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eКалибър на проводника\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e20 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eТип кабел\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eУсукана двойка, екраниран\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eКонектор A\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eMIL-C 5015, 2 гнезда, премиум, защитен от пръски\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eКонектор B\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eИзрязано на равно \/ летящи проводници\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eМатериал на обвивката\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eЖълт тефлон (FEP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eРаботна температура\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e-55 до +200 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eОсновно приложение\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eАналогово предаване на сигнал от трансдюсер към рафт\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eЧесто задавани инженерни въпроси\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eВ: Как трябва да се завърши щитният проводник на CB2W100-064, за да се избегнат заземителни контури?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eЩитът трябва да бъде заземен в една единствена точка, обикновено в мониторинговия рафт или структурното заземяване вътре в разклонителната кутия. Оставете щита плаващ и изолиран в края на трансдюсера, използвайки премиум изолирания корпус на конектора MIL-C 5015, за да предотвратите циркулиращи заземителни токове, които биха могли да повредят вибрационния сигнал.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eВ: Може ли този кабел да се използва с системи за близостни сензори или е предназначен само за акселерометри?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eТази 2-гнездна конфигурация MIL-C 5015 е основно проектирана за 2-жични акселерометри и сензори за скорост. Стандартните близостни сензори изискват 3-жични удължителни кабели (като серията 3300 XL). Проверете щифтовото разположение на трансдюсера преди инсталация.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eВ: Каква е максималната работна температура за жълтата тефлонова обвивка?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eТефлоновата (FEP) обвивка е сертифицирана за непрекъсната работа от -55 до +200 °C, което я прави подходяща за прокарване близо до горещи повърхности на корпуси на парни турбини, газови турбини и компресори.\u003c\/p\u003e\n\u003ch3\u003eНасоки за монтаж на място\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eПоддържайте минимален радиус на огъване от 75 мм по време на инсталация, за да предотвратите умора на вътрешните проводници или повреда на тефлоновия изолационен слой.\u003c\/li\u003e\n\u003cli\u003eПрокарвайте кабела през специални, заземени метални тръби при преминаване през открити структурни пролуки, за да осигурите механична защита и вторично екраниране срещу EMI.\u003c\/li\u003e\n\u003cli\u003eЗакрепете резбовия конектор MIL-C 5015 към корпуса на сензора с калибриран динамометричен ключ, като осигурите пълно компресиране на уплътнението против пръски без прекомерно затягане.\u003c\/li\u003e\n\u003cli\u003eДръжте междусистемния кабел изолиран от високоволтови AC захранващи линии с минимално разстояние от 300 мм, за да елиминирате пресичане на сигнали и индукционен шум върху нисковолтовия AC\/DC вибрационен сигнал.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668291383659,"sku":"CB2W100-064","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cb2w100-064-vsz41w0zaev_fe968a98-9d74-40cc-88e5-e1f3d7075186.jpg?v=1765520349"},{"product_id":"bently-nevada-106765-04-interconnect-cable-1","title":"Bently Nevada 106765-04 Interconnect Cable","description":"\u003ch3\u003eTechnical Summary\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e106765-04\u003c\/strong\u003e is a 4-meter interconnect cable engineered for transmitting dynamic eddy current sensor signals within the 3300 Proximity Transducer System. It establishes a dedicated electrical pathway linking the Proximitor Sensor to the 3300 rack monitor. The hardware minimizes signal attenuation and impedance mismatch, preventing RF reflections and phase shifts across the 24.3 mV\/um or 7.87 V\/mm scale factor. This shielding architecture blocks electromagnetic interference (EMI) to isolate critical vibration frequencies, eliminating reading drift and preventing false machine trips during high-frequency rotor dynamics tracking.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e106765\u003c\/strong\u003e - Base model identifier for high-performance coaxial interconnect cables optimized for Bently Nevada proximity systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04\u003c\/strong\u003e - Defines the specific physical length configuration representing 4.0 meters (13.1 feet) of overall cable length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e106765-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCoaxial, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003ePhysical Length\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e3300 Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e4.0 meters (length) x 3.2 mm (diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003ePassive device (0.0 mW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eImpedance\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e75.0 ohms nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eConnector Material\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eGold-plated brass (ClickLoc style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e Can the 106765-04 cable be modified or spliced in the field if the length is excessive?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Splicing or cutting this coaxial cable alters the total system capacitance and electrical length, which destroys the calibrated 7.87 V\/mm (200 mV\/mil) scale factor. Excess length must be looped and secured, not removed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e Is the 106765-04 directly compatible with the newer 3300 XL series Proximitor sensors?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It interfaces physically with 3300 XL hardware, but using the non-XL 106765 cable with an XL Proximitor limits system performance to legacy 3300 standards and may introduce minor linearity discrepancies. Use 3300 XL series extensions for full XL specs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What occurs if the coaxial connectors encounter moisture or oil contamination inside a conduit?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Liquid ingress causes cross-talk or insulation breakdown, shifting the gap voltage reading toward zero VDC and generating false probe fault alerts. Seal connections with silicone tape or fluid-tight terminal boxes.\u003c\/p\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm during installation. Avoid sharp bends or kinks that displace the internal dielectric layer and degrade signal propagation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Circuitry:\u003c\/strong\u003e Terminate the outer shield braid strictly at the monitor rack chassis ground. Leave the field sensor end floating inside an isolated terminal block to prevent ground loops that superimpose 50\/60 Hz noise onto the vibration signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Torque:\u003c\/strong\u003e Hand-tighten the coaxial connectors until the internal lock clicks. Apply a single drop of non-conductive thread-locking compound if operating under extreme structural vibration profiles; do not use pliers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Verification:\u003c\/strong\u003e Post-installation, verify the static gap voltage measures between -9.0 VDC and -11.0 VDC (nominal target -10.0 VDC) using a digital multimeter at the terminal block to confirm correct electrical length match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668291416427,"sku":"106765-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/106765-04-cldsrqajcgv_54326de0-3c18-4910-a66f-d540f4974baa.jpg?v=1765520350"},{"product_id":"bently-nevada-cb2w100-112-interconnect-cable","title":"Кабел за свързване Bently Nevada CB2W100-112","description":"\u003ch3\u003eПреглед на продукта\u003c\/h3\u003e\n\u003cp\u003eМеждинният кабел \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCB2W100-112\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eот \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eе проектиран за предаване на сигнал на дълги разстояния в системи за защита на индустриални машини и мониторинг на вибрации. Този кабел обикновено се инсталира между близостни сензори, мониторингови модули, разклонителни кутии и оборудване за мониторинг на състоянието, използвани на парни турбини, центробежни компресори, генератори, помпи и големи въртящи се машини, работещи в рафинерии, петрохимически заводи, минни и енергийни съоръжения.\u003c\/p\u003e\n\u003cp\u003eКабел с дължина 112 фута поддържа разширени изисквания за прокарване в големи производствени съоръжения, където мониторинговите шкафове са разположени далеч от въртящите се активи. Bently Nevada проектира серията CB2W100 за стабилна цялост на сигнала в електрически шумни индустриални среди, изложени на вибрации, замърсяване с масло, топлина и непрекъсната механична работа. Конструкцията на кабела поддържа надеждна комуникация между полеви трансдюсери и мониторингови системи, помагайки на екипите за поддръжка да поддържат точни данни за състоянието на машините и да намалят непланираните спирания, причинени от нестабилност на сигнала или повреди в окабеляването.\u003c\/p\u003e\n\u003ch3\u003eРазграждане на суфикса\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eКодов сегмент\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eОписание\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCB2W100\u003c\/td\u003e\n\u003ctd\u003eСерия междинни кабели\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e112\u003c\/td\u003e\n\u003ctd\u003eКабел с дължина 112 фута\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eЕквивалентна метрична дължина\u003c\/td\u003e\n\u003ctd\u003e34,1 метра\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eДизайн и приложение на кабела\u003c\/h3\u003e\n\u003cp\u003eСерията CB2W100 е проектирана за инсталации за мониторинг на индустриални машини, изискващи стабилна предаване на сигнал с нисък шум на дълги кабелни разстояния. Кабелът поддържа интеграция със системи за мониторинг на вибрации Bently Nevada, които често се инсталират на въртящо се оборудване по API.\u003c\/p\u003e\n\u003cp\u003eНеговата индустриална конструкция помага за устойчивост на екологични натоварвания, причинени от непрекъсната вибрация на машината, излагане на масло и повишени околни температури, често срещани в турбинни зали и компресорни станции. Дългата дължина на кабела позволява гъвкаво прокарване между полеви инструменти и централни мониторингови шкафове без необходимост от допълнителни междинни връзки.\u003c\/p\u003e\n\u003cp\u003eКабелът е широко използван в приложения за мониторинг на състоянието, където поддържането на надеждност на сигнала е критично за предиктивна поддръжка и ефективност на защитата на машините.\u003c\/p\u003e\n\u003ch3\u003eТехнически спецификации\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eПараметър\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eСпецификация\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eМодел\u003c\/td\u003e\n\u003ctd\u003eCB2W100-112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eМарка\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eТип продукт\u003c\/td\u003e\n\u003ctd\u003eСвързващ кабел\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eПроизход\u003c\/td\u003e\n\u003ctd\u003eСАЩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eДължина на кабела\u003c\/td\u003e\n\u003ctd\u003e112 фута\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eДължина на кабела в метрична система\u003c\/td\u003e\n\u003ctd\u003e34,1 метра\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eПриложение\u003c\/td\u003e\n\u003ctd\u003eЗащита на машини и мониторинг на вибрации\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eОбласт на инсталация\u003c\/td\u003e\n\u003ctd\u003eТурбини, компресори, мотори, генератори\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eТегло\u003c\/td\u003e\n\u003ctd\u003e1 кг\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eТегло при доставка\u003c\/td\u003e\n\u003ctd\u003e2 кг\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eРаботна температура\u003c\/td\u003e\n\u003ctd\u003eПодходящ за индустриални процесни среди\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eКонсумация на енергия\u003c\/td\u003e\n\u003ctd\u003eПасивен кабелен монтаж\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eКабелно трасе\u003c\/td\u003e\n\u003ctd\u003eДългосрочно индустриално предаване на сигнали\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eЧесто задавани въпроси\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eКакво е основното предназначение на кабела CB2W100-112?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eКабелът се използва за предаване на сигнали между полеви трансдюсери и системи за мониторинг на машини Bently Nevada, инсталирани на въртящо се оборудване.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eМоже ли този кабел да се инсталира в рафинерии и електроцентрали?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eДа. Кабелът е проектиран за индустриални среди с вибрации, топлина и непрекъсната работа на машините.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eКаква е общата дължина на кабела на този модел?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eТази версия осигурява обща дължина на кабела от 112 фута, което е приблизително 34,1 метра.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eПодходящ ли е CB2W100-112 за приложения с дълго кабелно трасе?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eДа. Удължената дължина на кабела поддържа инсталации, при които шкафовете за мониторинг са разположени далеч от машинните активи.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eНасоки за инсталация и препоръки от полето\u003c\/h3\u003e\n\u003cp\u003eПрокарвайте кабела отделно от проводниците на високоволтовите мотори и изходните проводници на VFD, за да минимизирате електромагнитните смущения в системите за мониторинг на машините.\u003c\/p\u003e\n\u003cp\u003eИзползвайте виброустойчиви скоби за кабели при инсталиране близо до турбини, компресори или големи мотори. Неподдържаните участъци от кабела могат да изпитат дългосрочна механична умора при непрекъснати вибрации.\u003c\/p\u003e\n\u003cp\u003eПроверете пътищата на кабелното трасе за остри метални ръбове и прекомерно нагряване преди пускане в експлоатация. Продължителното триене или термичен стрес може да намали експлоатационния живот на кабела в индустриални процесни среди.\u003c\/p\u003e\n\u003cp\u003eЗа външни инсталации използвайте запечатани тръбни системи и методи за защита на кабелите от индустриален клас, за да предотвратите проникване на влага и замърсяване от околната среда.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668300525931,"sku":"CB2W100-112","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CB2W100-112-4ygb2clpbnh_3367adcb-ed88-4a38-b1b8-adeb828f4be5.jpg?v=1765520524"},{"product_id":"bently-nevada-130539-30-interconnect-cable","title":"Bently Nevada 130539-30 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for demanding industrial monitoring environments, the \u003cstrong\u003eBently Nevada 130539-30\u003c\/strong\u003e is a high-integrity \u003cstrong\u003einterconnect cable\u003c\/strong\u003e designed to ensure seamless signal transmission between machinery sensors and critical monitoring systems. This industrial-grade assembly is constructed with a 3-conductor shielded 18 AWG (1.0 mm2) cable, offering robust physical protection and excellent resistance to electromagnetic interference (EMI). One end of the assembly features a specialized 3-socket plug encased in a protective fluorosilicone elastomer boot, providing optimal environmental sealing at the sensor connection point. The opposite termination consists of terminal lugs, allowing clean, secure connections within terminal boxes or control panels.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy-duty 3-conductor 18 AWG (1.0 mm2) copper wiring for high-fidelity signal transmission.\u003c\/li\u003e\n  \u003cli\u003eIntegrated shielding layer to mitigate electrical noise and maintain signal purity in harsh industrial environments.\u003c\/li\u003e\n  \u003cli\u003eFluorosilicone elastomer boot at the connector end for superior chemical and moisture resistance.\u003c\/li\u003e\n  \u003cli\u003eRobust 3-socket connector pre-terminated for reliable, vibration-resistant mating.\u003c\/li\u003e\n  \u003cli\u003eConvenient terminal lugs on the system end to facilitate quick installation in junction enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVibration and thrust position monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eConnection of dynamic sensors and velocity transmitters in power generation facilities.\u003c\/li\u003e\n  \u003cli\u003eOil and gas refining machinery protection systems.\u003c\/li\u003e\n  \u003cli\u003eIndustrial rotating machinery diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e130539-30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 feet (9.1 meters)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3-conductor shielded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e18 AWG (1.0 mm2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector A\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3-socket plug with fluorosilicone elastomer boot\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector B\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTerminal lugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the cable is routed with appropriate bend radiuses to prevent mechanical stress on the inner conductors and shield.\u003c\/li\u003e\n  \u003cli\u003eFor complete installation, routing, and termination details, refer to the Bently Nevada technical manual (part number 133080-01).\u003c\/li\u003e\n  \u003cli\u003eAvoid routing signal cables parallel to high-voltage power lines to minimize potential cross-talk and electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eVerify that the fluorosilicone elastomer boot is fully seated and sealed over the sensor mating interface to protect against fluid ingress.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668303966571,"sku":"130539-30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/130539-30-gs0oipq31zh_e3530a6a-c27a-45c7-98bf-afc3535e93fc.jpg?v=1765520637"},{"product_id":"bently-nevada-106765-22-3500-series-interconnect-cable","title":"Bently Nevada 106765-22 3500 Series Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eManaging serial communication links within industrial monitoring architectures relies on the high-fidelity signal transmission of the Bently Nevada 106765-22 Interconnect Cable. Engineered specifically for integration with the \u003cstrong\u003eBently Nevada 3500 Series Machinery Protection System\u003c\/strong\u003e, this cable establishes stable, low-latency connections between communication gateways (such as the 3500\/92) and external control systems, DCS, or PLC platforms. It features heavy-duty shielding and ruggedized industrial-grade connectors to maintain signal integrity in environments characterized by high electromagnetic interference (EMI) and mechanical stress.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-EMI Noise Immunity:\u003c\/strong\u003e Double-shielded conductor pairs block industrial electrostatic and electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Jacketing:\u003c\/strong\u003e Robust chemical and oil-resistant outer sheath protects conductors from degradation in harsh plant conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory-Terminated Connectors:\u003c\/strong\u003e Pre-terminated, precision-molded connectors ensure secure, vibration-proof mating with the module backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Signal Attenuation:\u003c\/strong\u003e Low-capacitance internal copper conductors allow for reliable data propagation over extended lengths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3500 System Integration:\u003c\/strong\u003e Linking the 3500\/92 Communication Gateway to Modbus RTU or serial networks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy Turbomachinery Monitoring:\u003c\/strong\u003e Data transmission pathways for steam turbine, gas turbine, and compressor diagnostics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Room Bridges:\u003c\/strong\u003e Interfacing rack-mounted monitoring units with remote distributed control systems (DCS).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e106765-22\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCompatible Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada 3500 Series (e.g., 3500\/92 Gateway)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCable Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSerial Interconnect Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShielding\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFoil and braided double shielding\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnited States (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe dash suffix in Bently Nevada cables denotes the specific length configuration. When replacing an existing interconnect, ensure that the length code (e.g., -22) is exact; field splicing or extending proprietary serial interconnect cables can introduce impedance mismatches and disrupt high-speed Modbus or host communications.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent data corruption or frame dropouts, avoid routing the 106765-22 cable alongside high-voltage AC motor drives, variable frequency drives (VFDs), or heavy power lines. Maintain a minimum of 30 cm physical separation from electrical conduit runs unless shielded, grounded metal ducting is utilized.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDuring deployment, verify that the minimum bend radius is strictly maintained to prevent microscopic fatigue in the inner shield braids. Always engage the mechanical strain relief and locking screws on the D-sub style or multi-pin terminal heads to isolate the termination pins from thermal and physical vibration cycles.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize the associated Bently Nevada 3500 rack and any interfacing control elements before mating or unmating the interconnect cable. Hot-plugging serial interfaces under high-vibration conditions or during active data cycles can cause transient voltage spikes, potentially damaging the gateway communication transceiver.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eIsolate and shut down power to the target communication module and external receiver port.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eRoute the cable through the dedicated low-voltage instrument cable tray, respecting the minimum bend radius.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eAlign the connector pins properly, seat the connector firmly into the port, and hand-tighten the retention screws.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSecure the shield ground point as specified by your local engineering and site wiring standard.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668304195947,"sku":"106765-22","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/106765-22-voxqh5k2lso_093e98f8-75a1-4dd9-bc6a-eb795610a3f5.jpg?v=1765520644"},{"product_id":"bently-nevada-84661-33-standard-armored-interconnect-cable","title":"Bently Nevada 84661-33 стандартен брониран свързващ кабел","description":"\u003ch3\u003eОписание\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 84661-33\u003c\/strong\u003e е тежкотоварен стандартен брониран кабелен комплект, проектиран да осигури висококачествени данни между трансдюсери на машини и централизирани мониторингови платформи. Тази специализирана връзка на сигнала разполага с неръждаема стоманена броня върху екраниран многожилен кабел с ядро 0.382 mm2 (22 AWG), който защитава чувствителните измервания от силни механични удари, структурна абразия и тежки срязващи напрежения. За да се гарантира безкомпромисна точност на канала в влажни или неклиматизирани полеви позиции, комплектът е оборудван с влагозащитен женски конектор на края на сензора за висока температура (HTVS) и индустриални пръстеновидни накрайници на страната на мониторинговата система. Проектиран да издържа на широки оперативни колебания, вътрешната конфигурация на екраниране минимизира високочестотния шум и прекъсванията на заземителната верига при широк температурен диапазон.\u003c\/p\u003e\n\u003ch3\u003eХарактеристики\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eОбвит в здрава неръждаема стоманена броня за здрава механична защита на място.\u003c\/li\u003e\n\u003cli\u003eИзграден с вътрешен 0.382 mm2 (22 AWG) екраниран инструментален кабел.\u003c\/li\u003e\n\u003cli\u003eЗавършен на фабриката със специализиран влагозащитен женски щепсел на края на HTVS сензора.\u003c\/li\u003e\n\u003cli\u003eПредварително конфигуриран с тежки индустриални пръстеновидни накрайници от страната на терминала на централната мониторингова система.\u003c\/li\u003e\n\u003cli\u003eОптимизираното електрическо екраниране предотвратява свързването на електромагнитен шум.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eПриложения\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eВисококачествено динамично маршрутизиране на сигнали от полеви инсталирани HTVS сензори за скорост към основни системи за защита на активите.\u003c\/li\u003e\n\u003cli\u003eТежки неклиматизирани производствени зони, изискващи защита с неръждаема стомана срещу екстремно износване или абразия.\u003c\/li\u003e\n\u003cli\u003eХидроелектрически централи и критична въртяща се техника, изложени на влажна, с висока влажност среда.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eИнформация за поръчка\u003c\/h3\u003e\n\u003cp\u003eМатрицата за означаване на модела за този стандартен брониран междинен кабел следва структурен модел за избор на дължина. Основният префикс на асамблеята е съчетан с конкретен суфикс, указващ общата дължина на кабела във футове.\u003c\/p\u003e\n\u003cp\u003eИзползвайте таблицата за конфигурация по-долу, за да идентифицирате или посочите алтернативни номера на модели за поръчка въз основа на изискванията за дължина на инсталацията, с включени формати за преобразуване в имперски (фута) и метрични (метри) единици:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eМодел за поръчка\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eДължина на кабела (фута)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eДължина на кабела (метри)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e84661-12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 фута\u003c\/td\u003e\n\u003ctd\u003e3.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e84661-33\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 фута\u003c\/td\u003e\n\u003ctd\u003e10.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e84661-40\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 фута\u003c\/td\u003e\n\u003ctd\u003e12.1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e84661-66\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 фута\u003c\/td\u003e\n\u003ctd\u003e20.1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\n\u003ch3\u003eТехнически спецификации\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eПараметър\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eСпецификация\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eПроизводител\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eКод на модела\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eТип продукт\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eСтандартен брониран междинен кабел\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eМатериал на бронята\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eНеръждаема стомана\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eСечение на проводника\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.382 мм2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eТип дизайн на кабела\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eЕкранован с външна броня\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eИнтерфейсна връзка на сензора\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eВлагозащитен женски конектор\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eИнтерфейсна връзка на монитора\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eПръстеновидни накрайници\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eРаботен температурен диапазон\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 до 121 °C (-20 до 250 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eДържава на произход\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eСъединени щати (U.S.A.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eНетно тегло на продукта\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 кг\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eТегло при доставка\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 кг\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eВръзки\/Интерфейси\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eПозиция на конектора\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eТип интерфейс за свързване\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eКрай на сензора HTVS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eВлагозащитен женски конектор\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eКрай на монитора\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eПръстеновидни накрайници\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eИнструкции за монтаж\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eРазположете бронирания кабел по определените канали на панела или открити структурни зони, като осигурите пътя да е свободен от тесни притискащи зони, които биха могли да смачкат защитния бронен слой.\u003c\/li\u003e\n\u003cli\u003eПодравнете и навийте влагозащитния женски конектор здраво върху интерфейса на сензорната глава HTVS, докато защитната уплътнителна лента не се постави напълно.\u003c\/li\u003e\n\u003cli\u003eЗакрепете индустриалните пръстеновидни накрайници здраво към определените точки на клемния блок вътре в шкафа на системата за наблюдение, оптимизирайки въртящия момент на винтовете на клемите, за да се предотврати разхлабване от вибрации.\u003c\/li\u003e\n\u003cli\u003eОтделете траекторията на кабела за инструментация от съседните разпределителни тръби за захранване на основния двигател, за да намалите риска от индуциране на шум на място.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308193643,"sku":"84661-33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/84661-33-b2tkpzvmmkt_e9754d5d-2df4-4874-959a-00ff97256d69.jpg?v=1765520745"},{"product_id":"bently-nevada-cb2w100-32-interconnect-cable","title":"Кабел за свързване Bently Nevada CB2W100-32","description":"\u003ch3\u003eПреглед на продукта\u003c\/h3\u003e\n\u003cp\u003eМеждинният кабел \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCB2W100-32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eот \u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eе проектиран за индустриални системи за мониторинг на вибрации и защита на машини, работещи в изискващи процесни среди. Този кабелен комплект използва MIL-C 5015 водозащитни конектори с 2 гнезда и поддържа надеждна предаване на сигнала между близостни сонди, модули за мониторинг и полево оборудване, инсталирани на турбини, компресори, помпи и големи въртящи се машини.\u003c\/p\u003e\n\u003cp\u003eКабелът разполага с 20 AWG усукани двойки проводници с екраниране и жълта тефлонова обвивка, проектирана за индустриални приложения при високи температури, където излагането на масло, вибрациите и електромагнитните смущения са чести. Bently Nevada включва заключващо пръстенче, уплътнение на адаптера и О-пръстен за подобряване на уплътнението срещу околната среда и стабилността на конектора при дългосрочна работа на място. Дължината на кабела от 32 фута поддържа гъвкаво прокарване вътре в корпуси на турбини, компресорни платформи, зони за управление на мотори и шкафове за мониторинг на рафинерии, като същевременно запазва стабилна цялост на сигнала в критични вериги за защита на машините.\u003c\/p\u003e\n\u003ch3\u003eРазбивка на суфикса\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eКодов сегмент\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eОписание\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCB2W100\u003c\/td\u003e\n\u003ctd\u003eMIL-C 5015 водозащитен междинен кабелен комплект\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003eДължина на кабела 32 фута\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eЕквивалентна дължина на кабела в метрична система\u003c\/td\u003e\n\u003ctd\u003e9,75 метра\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eКонструкция на кабела и дизайн на конектора\u003c\/h3\u003e\n\u003cp\u003eСерията CB2W100 използва усукани двойки екранирани проводници за намаляване на електрическите смущения в индустриални среди с висока електромагнитна активност. Жълтата обвивка от тефлон осигурява подобрена устойчивост на топлина, замърсяване с масло, износване и химическо въздействие, често срещани близо до инсталации с въртящо се оборудване.\u003c\/p\u003e\n\u003cp\u003eКабелният комплект включва MIL-C 5015 конектори с 2 гнезда с водозащитна конструкция за индустриална надеждност на място. Изолираната конфигурация с изрязани на равно краища опростява персонализираната интеграция на място в шкафове за мониторинг и разклонителни сборки. Включената заключваща апаратура подобрява задържането на конектора при непрекъснати вибрации на машината.\u003c\/p\u003e\n\u003cp\u003eТози кабел често се използва в системи за защита на машини Bently Nevada, прилагани в рафинерийни технологични линии, оборудване за производство на електроенергия, LNG съоръжения и офшорни инсталации на въртящи се машини.\u003c\/p\u003e\n\u003ch3\u003eТехнически спецификации\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eПараметър\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eСпецификация\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eМодел\u003c\/td\u003e\n\u003ctd\u003eCB2W100-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eМарка\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eТип продукт\u003c\/td\u003e\n\u003ctd\u003eСвързващ кабел\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eПроизход\u003c\/td\u003e\n\u003ctd\u003eСАЩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eТип конектор\u003c\/td\u003e\n\u003ctd\u003eMIL-C 5015, 2 гнезда, водозащитен\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eТип кабел\u003c\/td\u003e\n\u003ctd\u003e20 AWG усукана двойка, екранирана\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eМатериал на обвивката\u003c\/td\u003e\n\u003ctd\u003eЖълт тефлон\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eТип на прекъсване\u003c\/td\u003e\n\u003ctd\u003eИзолиран до тъп разрез\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eВключени аксесоари\u003c\/td\u003e\n\u003ctd\u003eЗаключващо пръстенче, адаптерно уплътнение, О-пръстен\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eДължина на кабела\u003c\/td\u003e\n\u003ctd\u003e32 фута\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eДължина на кабела в метрична система\u003c\/td\u003e\n\u003ctd\u003e9,75 метра\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eТегло\u003c\/td\u003e\n\u003ctd\u003e2 кг\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eТегло при доставка\u003c\/td\u003e\n\u003ctd\u003e2 кг\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eРаботна температура\u003c\/td\u003e\n\u003ctd\u003eПодходящ за индустриални среди с висока температура\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eКонсумация на енергия\u003c\/td\u003e\n\u003ctd\u003eПасивен кабелен комплект\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eПриложение\u003c\/td\u003e\n\u003ctd\u003eСистеми за защита на машини и мониторинг на вибрации\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eЧесто задавани въпроси\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eКои мониторингови системи използват кабела CB2W100-32?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eКабелът често се използва с вибрационни системи за мониторинг Bently Nevada, инсталации с близкодействуващи сензори и приложения за защита на въртящи се машини.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eВключва ли кабелът хардуер за монтаж на място?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eДа. Сглобката включва заключващо пръстенче, адаптерно уплътнение и О-пръстен за подобрено уплътнение и задържане на конектора.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eКакъв тип екраниране използва този кабел?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eКабелът използва усукани двойки с екранирани проводници, за да намали електромагнитните смущения в индустриална среда.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eМоже ли този кабел да работи близо до турбини и компресори?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eДа. Тефлоновата обвивка и индустриалният дизайн на конектора поддържат инсталация в зони с висока температура и силни вибрации.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eНасоки за инсталация и инженерни препоръки\u003c\/h3\u003e\n\u003cp\u003eПрокарайте кабела отделно от високоволтовите захранващи кабели на мотора и изходните кабели на VFD, за да минимизирате електрическите смущения в защитните вериги на машините.\u003c\/p\u003e\n\u003cp\u003eПо време на инсталация избягвайте прекомерно огъване на кабела близо до точките на прекъсване на конектора. Твърде тесният радиус на огъване може да намали дългосрочната надеждност на проводника при непрекъснати вибрации.\u003c\/p\u003e\n\u003cp\u003eПроверете захващането на заключващото пръстенче и уплътнителните компоненти преди стартиране в открити или миещи се производствени зони. Неправилното уплътнение на конектора може да позволи проникване на влага в мониторинговите вериги.\u003c\/p\u003e\n\u003cp\u003eЗа турбинни и компресорни инсталации закрепете кабела с виброустойчиви скоби, за да предотвратите разхлабване на конектора по време на дългосрочна работа на машината.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668310585707,"sku":"CB2W100-32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cb2w100-32-1n0g3cvnptc_00d564cc-d6fe-4cb2-9979-b9f237130c7a.jpg?v=1765520839"},{"product_id":"bently-nevada-9571-02-standard-interconnect-cable","title":"Bently Nevada 9571-02 Standard Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered to deliver high-integrity signal transmission within critical machinery protection architectures, the \u003cstrong\u003eBently Nevada 9571-02\u003c\/strong\u003e facilitates low-noise connectivity between industrial transducers and monitoring systems. This heavy-duty cable features a \u003cstrong\u003e2-conductor twisted, shielded 22 AWG\u003c\/strong\u003e construction that actively minimizes electromagnetic interference (EMI) and cross-talk in harsh electromagnetic environments. Designed with a specialized \u003cstrong\u003e2-socket moisture-resistant female connector\u003c\/strong\u003e at one end and rugged terminal lugs at the other, this 2-foot cable ensures a highly secure electrical and mechanical interface for critical vibration monitoring points. It is built specifically for integration with local monitor racks, excluding use with the 21128 Velocity Transducer Housing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Noise Rejection:\u003c\/strong\u003e Twisted-pair configuration combined with an integrated shield drain wire isolates fragile transducer signals from plant EMI\/RFI.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Termination:\u003c\/strong\u003e Equipped with a molded, moisture-resistant 2-socket female connector for reliable sensor-side sealing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Panel Interfacing:\u003c\/strong\u003e Pre-terminated with high-quality terminal lugs for direct, reliable installation onto barrier strips and monitor backplanes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Mechanics:\u003c\/strong\u003e Optimally sized 22 AWG conductors maintain electrical continuity and mechanical durability under structural vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-Run Optimization:\u003c\/strong\u003e 2-foot minimum length design prevents excess cable slack, keeping control cabinets organized and free of inductive loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eMachinery protection system loops (e.g., Bently Nevada 3500 and 1900 series monitors).\u003c\/li\u003e\n  \u003cli\u003eProx probes and vibration sensor-to-junction box connections.\u003c\/li\u003e\n  \u003cli\u003eBalance-of-plant rotating machinery health monitoring.\u003c\/li\u003e\n  \u003cli\u003eShort-run internal cabinet and local structural transducer routing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.95rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e9571-02\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCable Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStandard Interconnect Cable (2-Conductor Twisted, Shielded)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConductor Gauge\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e22 AWG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2 feet (0.6 meters)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnector End A\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2-socket moisture-resistant female connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnector End B\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTerminal Lugs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnited States (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNet Physical Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.11 kg (0.24 lbs) (Calculated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.0 kg (including packaging and protective spooling)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.95rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eConnector Pin \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eFunction \/ Signal Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSocket Pin A\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSignal High \/ Dynamic Signal (+)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSocket Pin B\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSignal Common \/ Return (-)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTerminal Lugs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTermination points for terminal block connections at monitor panel\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOuter Shield \/ Drain\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGrounding shield (MUST terminate only at the monitor common ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 9571-02 interconnect cable is optimized for standard industrial monitor configurations. It is crucial to note that this specific standard cable is \u003cstrong\u003enot compatible\u003c\/strong\u003e with the Bently Nevada 21128 Velocity Transducer Housing due to diameter clearances and physical connection constraints. If your plant utilizes the 21128 housing, you must source a specialized splash-resistant or armored cable assembly built specifically for that enclosure profile.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this is a non-armored variant, care must be taken during routing. Avoid routing the 9571-02 directly parallel to high-voltage AC motor lines or variable frequency drive (VFD) output cables. Lack of mechanical armor means this cable should always be housed within dedicated, grounded conduit or cable trays when routed outside of localized, enclosed instrument cabinets to prevent physical shearing or crushing.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo ensure the integrity of high-frequency vibration diagnostics, always terminate the cable's shield drain wire at the monitor rack ground. Never ground the shield at both ends; double-grounding creates ground loops that inject 50\/60 Hz electrical noise into the signal path, which can lead to false instrumentation trips or corrupted spectral data.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: ELECTRICAL HAZARD\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eBefore starting the installation or termination of the 9571-02 cable, ensure the corresponding monitor panel loop power is completely de-energized. Verify there is no residual energy on adjacent terminal strips. Failure to isolate power paths can lead to short circuits, damage to delicate input card electronics, or personnel injury.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eRoute the interconnect cable from the transducer mounting point to the monitor cabinet, ensuring the bend radius does not fall below 3 inches (76 mm) to prevent internal wire strain.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eAlign the keying of the 2-socket female connector with the transducer plug. Fully insert and thread the coupling collar to compress the moisture-resistant seal. Hand-tighten securely.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eConnect the terminal lugs at the opposite end to the assigned screw terminal block of the monitor rack. Ensure the shield drain wire is connected cleanly to the instrument Earth terminal and insulated along the rest of its length.\u003c\/span\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668311830891,"sku":"9571-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9571-02-nbt0yfepqpp_389554c6-7316-4e10-ab97-76a16a61418a.jpg?v=1765520874"},{"product_id":"bently-nevada-84661-07-interconnect-cable","title":"Bently Nevada 84661-07 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOptimizing signal transmission in demanding industrial environments, this rugged \u003cstrong\u003eBently Nevada 84661-07\u003c\/strong\u003e interconnect cable serves as a dependable link between proximity sensors and monitoring systems. Engineered with a \u003cstrong\u003e2-conductor twisted, shielded 22 AWG armored cable\u003c\/strong\u003e construction, this assembly minimizes electromagnetic and radio frequency interference to preserve signal integrity for critical machinery protection metrics. The cable is terminated with a moisture-resistant 2-socket female connector at one end and raw terminal lugs at the other, providing a fast, secure field connection for continuous vibration monitoring applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHeavy-Duty Armor:\u003c\/strong\u003e Built-in armored conduit protects the internal conductors from mechanical crushing, abrasive wear, and harsh factory conditions.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eShielded Noise Rejection:\u003c\/strong\u003e Twisted-pair wiring configuration combined with overall shielding effectively blocks ambient electromagnetic noise.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e Features a robust 2-socket moisture-resistant female connector to maintain connection integrity in humid, oily, or wet environments.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eVersatile Termination:\u003c\/strong\u003e Standard pre-crimped terminal lugs facilitate direct connection into system terminal blocks or barrier strips.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eTurbine, compressor, and generator vibration-monitoring setups.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eBently Nevada machinery protection and diagnostic rack connections.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003ePetrochemical plants, power generation facilities, and heavy manufacturing sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-family: sans-serif; text-align: left;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel\/Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e84661-07\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCable Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2-conductor twisted, shielded armored cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConductor Gauge\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e22 AWG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConnector A\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2-socket moisture-resistant female connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConnector B\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTerminal lugs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e7 feet (2.13 meters)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States (U.S.A.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.0 kg (6.6 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis cable is highly specialized for transducer networks requiring high physical resilience. If a longer layout is needed for different machine footprints, verify matching option suffixes (such as -10 or -25) to secure the correct pre-assembled field length without requiring manual splice junctions.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIn proximity sensor loops, grounding loops represent a major source of signal drift or false alarms. Ensure that the cable shield is grounded at only one end (typically at the system terminal panel\/instrument ground) and left floating at the transducer connector end. Allowing multi-point grounding on shields often introduces ground loop currents that corrupt sensitive AC dynamic signals.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eEnsure that the moisture-resistant plug is fully seated and threaded tight on the sensor mating end. Fluid ingress (such as oil or water condensation) within the plug interface will degrade insulation resistance, causing erratic gap voltage readings and system faults.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eAlways verify that the monitoring rack and related machinery power supply channels are completely de-energized before handling field sensor connections. Discharging any static or residual system charges prior to terminating the terminal lugs prevents unexpected transients from damaging delicate input cards.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv\u003eRoute the cable through protected pathways, keeping a safe distance from high-voltage motor cables to avoid noise coupling. Observe the minimum bend radius constraints of the armored conduit.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv\u003eConnect the moisture-resistant 2-socket connector firmly onto the proximity sensor mating plug. Use proper sealant or boots if direct washdowns are expected.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv\u003eTerminate the wire lugs at the instrument panel terminal strip, strictly observing the correct signal\/common polarity as specified in your transmitter manual. Keep shield drain wire isolated as per system drawing constraints.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668312781163,"sku":"84661-07","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/84661-07-kugnptcg4n2_564b7e1d-5064-43dd-8bf7-4fb7e8a13684.jpg?v=1765520906"},{"product_id":"bently-nevada-18622-010-01-interconnect-cable","title":"Bently Nevada 18622-010-01 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-integrity signal pathway applications, the \u003cstrong\u003e18622-010-01\u003c\/strong\u003e is a ruggedized \u003cstrong\u003einterconnect cable\u003c\/strong\u003e designed to bridge the gap between proximity probe sensors and machinery monitoring systems. This assembly is built to withstand harsh industrial environments, ensuring reliable data transmission for vibration and position monitoring systems.\u003c\/p\u003e\n\n\u003cp\u003eThe construction of this cable assembly incorporates high-grade Teflon insulation, providing excellent thermal stability and resistance to chemical exposure. Encased in a robust protective armor cladding, the cable is protected against physical impacts, abrasion, and mechanical stress commonly encountered in heavy industrial plants.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Durability:\u003c\/strong\u003e Teflon insulation offers exceptional resistance to elevated temperatures and environmental degradation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Armor Cladding:\u003c\/strong\u003e Integrated stainless steel flexible armor provides high crush resistance and protection against sharp bends.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Length:\u003c\/strong\u003e 10-foot physical length optimized for standard terminal box and transmitter connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Signal Loss:\u003c\/strong\u003e Coaxial core design minimizes signal attenuation and maintains measurement accuracy for critical vibration metrics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCritical rotating machinery protection\u003c\/li\u003e\n  \u003cli\u003ePower generation facilities and steam\/gas turbine monitoring\u003c\/li\u003e\n  \u003cli\u003eOil and gas refinery instrumentation\u003c\/li\u003e\n  \u003cli\u003eChemical processing plants requiring robust sensor cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth\u003eManufacturer\u003c\/th\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003ePart Number\u003c\/th\u003e\n      \u003ctd\u003e18622-010-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eProduct Type\u003c\/th\u003e\n      \u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCable Length\u003c\/th\u003e\n      \u003ctd\u003e10 ft\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eArmor Option\u003c\/th\u003e\n      \u003ctd\u003eWith protective armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInsulation Material\u003c\/th\u003e\n      \u003ctd\u003eTeflon (PTFE)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCountry of Origin\u003c\/th\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintain the specified minimum bend radius during installation to prevent crimping the internal coaxial conductor or outer armor.\u003c\/li\u003e\n  \u003cli\u003eEnsure the armor is grounded properly to prevent electromagnetic interference from distorting the proximity probe signal.\u003c\/li\u003e\n  \u003cli\u003eRoute the cable away from high-voltage conduit lines and high-temperature steam lines where possible.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668315566443,"sku":"18622-010-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/18622-010-01-zw4ukim0rzg_e7b7f82b-52f8-46f6-92cf-ff94c37d4c1a.jpg?v=1765521005"},{"product_id":"bently-nevada-89477-20-interconnect-cable-20-ft-industrial-signal-link","title":"Bently Nevada 89477-20 Interconnect Cable 20 ft Industrial Signal Link","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 89477-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an interconnect cable designed for vibration monitoring and machinery protection systems where stable signal transmission between field devices and monitoring modules is required. It is commonly used in turbines, compressors, pumps, and industrial rotating equipment across power generation and process industries.\u003c\/p\u003e\n\u003cp\u003eThis cable provides a direct electrical link between system components, ensuring reliable data transfer in environments with vibration, electrical noise, and continuous industrial operation. It supports consistent signal integrity for condition monitoring systems where measurement accuracy directly affects machine protection decisions.\u003c\/p\u003e\n\u003cp\u003eThe 20 ft length configuration supports flexible installation in control cabinets and field-mounted monitoring setups.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e89477\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20 ft cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis simplified configuration defines cable family type and physical length for system integration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e89477-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e20 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSignal transmission for monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Role\u003c\/td\u003e\n\u003ctd\u003eInterconnect between monitoring and field devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eIndustrial machinery monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is designed for stable low-noise signal transmission in industrial environments where electromagnetic interference and mechanical vibration are present.\u003c\/p\u003e\n\u003cp\u003eIt ensures consistent connectivity between monitoring modules and field instrumentation, supporting accurate vibration and condition monitoring data acquisition.\u003c\/p\u003e\n\u003cp\u003eThe cable structure is optimized for durability under continuous industrial operation conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbine systems, compressors, pumps, and industrial monitoring panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is its main function?\u003c\/strong\u003e\u003cbr\u003eIt provides electrical interconnection between monitoring system components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for industrial vibration and electrical noise conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect performance?\u003c\/strong\u003e\u003cbr\u003eWithin specified design limits, 20 ft supports stable signal transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eRoute cable away from high-voltage power lines to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bends to maintain conductor integrity and signal stability.\u003c\/p\u003e\n\u003cp\u003eEnsure connectors are fully seated to prevent intermittent signal loss.\u003c\/p\u003e\n\u003cp\u003eUse proper cable management to reduce vibration-induced mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper grounding practices to ensure signal stability in noisy environments.\u003c\/p\u003e\n\u003cp\u003eInspect connector interfaces during scheduled maintenance cycles.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical tension on cable ends during installation.\u003c\/p\u003e\n\u003cp\u003eUse standardized routing paths inside control panels to improve reliability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319007083,"sku":"89477-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/89477-20-3chmqkzrnkk_aeabdb4b-577f-4515-af7c-d9847d23c650.jpg?v=1765521126"},{"product_id":"bently-nevada-84661-34-10-meter-velomitor-interconnect-cable","title":"Bently Nevada 84661-34 | 10 meter Velomitor Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 84661-34\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 10 meter Velomitor interconnect cable designed for reliable signal transmission between velocity transducers and vibration monitoring systems. It is used in industrial machinery protection systems across power generation, oil and gas, and process industries where stable vibration signal integrity is critical.\u003c\/p\u003e\n\u003cp\u003eThis cable assembly provides a rugged armored construction to protect signal transmission in high-vibration and harsh environmental conditions. It ensures consistent data transfer from HTVS velocity sensors to monitoring equipment without degradation caused by electrical noise or mechanical stress.\u003c\/p\u003e\n\u003cp\u003eThe stainless steel armor layer enhances mechanical durability, making it suitable for installations exposed to abrasion, moisture, and industrial handling stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConstruction \u0026amp; Design Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Core\u003c\/td\u003e\n\u003ctd\u003eShielded 22 AWG (0.382 mm2) conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eStainless steel protective layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor End\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector (HTVS side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor End\u003c\/td\u003e\n\u003ctd\u003eRing lug termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe structure is engineered to maintain signal integrity while providing mechanical protection in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e84661-34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eArmored interconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Connection\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Connection\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVelocity transducer signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is designed to maintain stable low-noise signal transmission between velocity sensors and monitoring systems in electrically and mechanically harsh environments.\u003c\/p\u003e\n\u003cp\u003eStainless steel armor protects the internal conductors from abrasion and mechanical damage during installation and long-term operation.\u003c\/p\u003e\n\u003cp\u003eShielded conductor design reduces electromagnetic interference, ensuring signal accuracy in environments with variable frequency drives and high-power electrical systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in power plants, refineries, and industrial machinery vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is armored cable important?\u003c\/strong\u003e\u003cbr\u003eIt protects signal integrity against mechanical damage and harsh industrial handling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with all Velomitor sensors?\u003c\/strong\u003e\u003cbr\u003eIt is designed for compatible Bently Nevada Velomitor and HTVS systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it reduce electrical noise?\u003c\/strong\u003e\u003cbr\u003eYes. Shielded construction helps minimize EMI interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid excessive bending during installation to prevent internal conductor stress.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shield layer to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eRoute cable away from high-voltage and VFD power lines for optimal signal integrity.\u003c\/p\u003e\n\u003cp\u003eSecure stainless steel armor properly at mounting points to prevent vibration-induced fatigue.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius to avoid long-term mechanical fatigue in armored structure.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing periodically in moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief at both ends to prevent mechanical load transfer to connectors.\u003c\/p\u003e\n\u003cp\u003eEnsure ring lug termination is firmly secured to monitoring system terminals for stable signal transmission.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319269227,"sku":"84661-34","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/84661-34-xineykv00ar_bd189d67-6de3-412b-8dbc-91f4c1b8515a.jpg?v=1765521137"},{"product_id":"bently-nevada-16925-80-interconnect-cable-without-armor","title":"Bently Nevada 16925-80 Interconnect Cable Without Armor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16925-80\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada interconnect cable designed for signal transmission within industrial vibration monitoring systems where flexible routing is required. It connects system modules, proximity measurement chains, and monitoring interfaces in Bently Nevada architectures used for rotating machinery protection. The cable maintains stable electrical performance in environments with continuous vibration and electrical noise.\u003c\/p\u003e\n\u003cp\u003eThis model is commonly deployed in power plants, oil refineries, compressor stations, and heavy industrial facilities. It supports reliable communication between monitoring components while reducing installation complexity in non-armored routing applications. The absence of armor improves flexibility for cabinet and rack wiring layouts where mechanical protection is already provided by conduit or controlled installation paths.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16925 = Interconnect cable base model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e80 = 80 ft fixed cable length option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWithout armor = flexible standard cable construction without mechanical steel protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable is designed for internal system interconnection where routing flexibility is prioritized over mechanical reinforcement. It maintains stable impedance characteristics suitable for vibration signal transmission in Bently Nevada monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16925-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable Without Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e80 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eNon-armored flexible industrial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring system interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade shielded cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eCabinet and rack wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.131 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the 16925-80 cable typically installed?\u003c\/strong\u003e\u003cbr\u003eIt is used inside control cabinets, racks, and protected industrial wiring paths for monitoring system interconnection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable provide mechanical protection against crushing?\u003c\/strong\u003e\u003cbr\u003eNo. It is non-armored and relies on installation routing or conduit for mechanical protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high vibration environments?\u003c\/strong\u003e\u003cbr\u003eYes, but it must be installed in protected routing paths to avoid mechanical damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with all Bently Nevada systems?\u003c\/strong\u003e\u003cbr\u003eIt is compatible only when system interconnection specifications match the required length and connector configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the cable inside protected conduits or cable trays when used in high vibration industrial environments. Avoid direct exposure to moving machinery or sharp edges.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high voltage power cables and VFD output lines to reduce electromagnetic interference and signal distortion.\u003c\/p\u003e\n\u003cp\u003eUse proper grounding for cable shielding at a single reference point to prevent ground loop noise in vibration monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321825131,"sku":"16925-80","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16925-80-a351m02eaoc_7af58e61-be66-4f3a-bb94-2662eec300f9.jpg?v=1765521172"},{"product_id":"16925-23-bently-nevada-interconnect-cable","title":"16925-23| Bently Nevada | Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16925-23\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada interconnect cable designed for reliable signal transmission between vibration monitoring components in industrial protection systems. It forms part of the signal path used in proximity, velocity, and condition monitoring architectures where stable electrical continuity directly affects measurement accuracy and machine protection response time.\u003c\/p\u003e\n\u003cp\u003eThis cable is widely used in turbine systems, compressors, pumps, and rotating machinery installations across power generation, oil and gas, and heavy industrial plants. It ensures consistent signal integrity between field sensors and monitoring modules, reducing the risk of data loss caused by electromagnetic interference or mechanical stress in harsh environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16925 = Interconnect cable base model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e23 = 23 ft cable length configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable is designed for direct interconnection within Bently Nevada monitoring systems. It maintains controlled electrical characteristics suitable for vibration signal transmission and supports stable operation under continuous industrial vibration and electrical noise conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16925-23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e23 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Function\u003c\/td\u003e\n\u003ctd\u003eSignal interconnection for monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring system wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada condition monitoring platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade shielded construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eIndustrial machinery and control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the 16925-23 cable used in a monitoring system?\u003c\/strong\u003e\u003cbr\u003eIt is used as an interconnect link between vibration monitoring modules and system components in Bently Nevada architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high noise environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed with shielding suitable for industrial electromagnetic interference environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable length fixed at 23 ft?\u003c\/strong\u003e\u003cbr\u003eYes. The “23” suffix defines a fixed 23 ft factory configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable replace other interconnect models?\u003c\/strong\u003e\u003cbr\u003eReplacement is possible only if electrical and length specifications match system requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the cable away from high voltage power lines and VFD output cables to minimize induced electrical noise. Separation improves signal stability in vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003eAvoid tight bending near connectors and junction points. Excess mechanical stress can degrade shielding performance and reduce long-term reliability.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of cable shielding at a single system reference point to prevent ground loop interference in turbine and compressor monitoring environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321857899,"sku":"16925-23","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16925-23-104ffwk3jjl_edf3297d-cdab-4cf7-9cbf-0d5dff551175.jpg?v=1765521173"},{"product_id":"bently-nevada-18622-015-01-interconnect-cable-assembly","title":"Bently Nevada 18622-015-01 Interconnect Cable Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e18622-015-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterconnect cable from Bently Nevada provides reliable signal transmission between vibration monitoring system components in industrial machinery protection applications. It is widely used in power generation plants, oil refineries, petrochemical facilities, and heavy industrial equipment where stable communication between proximity probes, extension systems, and monitoring modules is required for continuous machine condition monitoring.\u003c\/p\u003e\n\u003cp\u003eThis interconnect cable is designed for integration within Bently Nevada monitoring architectures and supports stable electrical signal transfer under high vibration and harsh environmental conditions. The 15 ft (4.572 m) cable length provides flexible installation routing between enclosure systems and field-mounted instrumentation. The armored Teflon cable construction improves resistance to abrasion, chemical exposure, and mechanical stress, making it suitable for demanding industrial environments. The compact design supports clean cable management inside control cabinets and machinery protection systems, helping maintain signal integrity and reducing the risk of unplanned shutdown events caused by wiring degradation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e18622\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable series identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e015\u003c\/td\u003e\n\u003ctd\u003eCable length: 15 ft (4.572 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eArmored Teflon cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e18622-015-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e15 ft (4.572 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored, Teflon insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade signal shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main function of this interconnect cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides stable signal transmission between vibration monitoring components in Bently Nevada machinery protection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is Teflon insulation used in this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTeflon improves resistance to high temperature, chemical exposure, and industrial environmental stress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high vibration environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The armored construction is designed for industrial vibration and mechanical stress conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with all Bently Nevada systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is designed for use within compatible Bently Nevada monitoring and proximity measurement architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from high power conductors and VFD output lines to minimize electromagnetic interference in monitoring signals.\u003c\/p\u003e\n\u003cp\u003eEnsure proper mechanical fixation along cable trays to prevent vibration-induced fatigue at connector points in rotating machinery environments.\u003c\/p\u003e\n\u003cp\u003eAvoid tight bending near termination points to maintain long-term shielding integrity and stable signal performance in industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322644331,"sku":"18622-015-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/18622-015-01-vtm1cdyn4v0_d9fb4d7d-b80f-478a-a0ad-8e330fa758a2.jpg?v=1765521204"},{"product_id":"bently-nevada-16710-65-interconnect-cable-1","title":"Bently Nevada 16710-65 Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65 \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty, 3-conductor shielded interconnect cable designed to maintain signal integrity between proximity transducers and monitoring systems. Engineered for the Bently Nevada 3300 and 3500 Machinery Protection Systems, this cable is essential for transmitting critical vibration, position, and speed data in high-interference industrial environments. Its armored construction provides superior mechanical protection against physical abrasion and crushing forces commonly found in oil refineries, power plants, and heavy manufacturing facilities. By utilizing high-grade 22 AWG wiring and robust shielding, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeffectively eliminates electromagnetic interference (EMI) that can cause false alarms or signal drift. Implementing genuine Bently Nevada cabling is a vital strategy for ensuring the reliability of Turbomachinery Instrumentation (TSI), directly reducing unplanned downtime through stable, high-fidelity data transmission.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a specific Bently Nevada configuration logic for length and termination:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16710:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the base cable assembly type. This includes a 3-conductor, 22 AWG (0.5 mm2) shielded wire housed within flexible stainless steel armor. The assembly features a pre-installed 3-socket plug at the sensor end and terminal lugs at the monitor end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-65:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates the total cable length. In this configuration, the cable is precisely manufactured to a length of 65 feet (approximately 20 meters), allowing for significant distance between the field-mounted junction box and the centralized control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16710-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Conductor Shielded Armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 feet (20 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Socket Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the armored jacket provide environmental sealing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stainless steel armor provides exceptional mechanical protection against impact and abrasion; however, it is not a liquid-tight seal. For applications involving constant immersion or heavy chemical spray, the cable should be routed through additional liquid-tight conduit or housed in sealed trays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be shortened in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the terminal lug end can technically be trimmed, it is not recommended as it destroys the factory-certified termination. Field modifications can introduce impedance mismatches or shielding gaps. It is best practice to order the specific length required for the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the shield connected to the socket plug?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shield is typically isolated at the sensor end plug to prevent ground loops. In a standard Bently Nevada installation, the shield should be grounded only at the monitor rack or the common point in the signal conditioning housing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProper grounding is the most critical factor when installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65\u003c\/strong\u003e. The cable shield must be terminated at the instrument ground in the 3500 rack or the Proximitor housing. Ensure the shield is not inadvertently grounded at the sensor end or at any intermediate junction boxes. \"Floating\" the shield at the sensor end prevents circulating ground currents that can corrupt low-voltage vibration signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius and Mechanical Stress\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDespite the flexible armor, the cable has a minimum bend radius that must be respected to prevent internal conductor fatigue. Avoid sharp 90-degree bends. When securing the cable to machine supports or tray systems, use stainless steel ties or clamps that do not compress the armor, as internal insulation damage can lead to intermittent short circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn Class 1 Div 1 or Zone 0\/1 environments, ensure the armored cable is installed in accordance with local explosion-proof or intrinsically safe wiring standards. The armor provides mechanical protection but does not replace the need for certified cable glands or seals where the cable enters a pressurized or flameproof enclosure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322906475,"sku":"16710-65","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-65-interconnect-cable-y3wsgre5hbc_116b3aaa-6d35-48c4-a8bf-f4c822366c20.jpg?v=1765447167"},{"product_id":"106765-25-bently-nevada-interconnect-cable","title":"106765-25 | Bently Nevada | Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a specialized, ruggedized interconnect cable assembly designed specifically for the Bently Nevada 330525 Velomitor XA (eXtended Application) Piezo-Velocity Sensor series. In critical industrial sectors such as power generation, wastewater treatment, and offshore oil platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the vital link for transmitting high-fidelity vibration data in high-moisture and corrosive environments. By utilizing a unique weatherproof connector system, this cable allows for the direct mounting of sensors without the need for additional protective housings. This streamlined architecture significantly reduces installation complexity while ensuring maximum uptime for rotating assets by maintaining IP-65 and NEMA 4X sealing integrity under the most grueling field conditions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown: 106765-AA\u003c\/h3\u003e\n\u003cp\u003eThe 106765 series uses a modular suffix system to ensure the precise cable reach required for specific machine train geometries:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e106765 Base Model:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDenotes the high-performance interconnect cable assembly designed for Velomitor XA sensors, featuring 316L stainless steel hardware compatibility and weatherproof sealing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAA Option (Length):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDefines the total cable length in meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-25 Suffix:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRepresents a fixed length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25 meters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(approximately 82 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Bently Nevada practice dictates that these specialized cables are typically engineered and ordered in 3-meter increments to maintain electrical impedance consistency across the monitoring loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e106765-25\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Sensors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330525 Velomitor XA Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 meters (82 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP-65 and NEMA 4X (When properly mated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-55 to +121 deg C (-67 to +250 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWeatherproof high-grade synthetic \/ Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Insights \u0026amp; FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 106765-25 compatible with the standard 330500 Velomitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the internal wiring may be similar, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for the \"XA\" (Extended Application) version. The XA series features a unique connector intended for use without a separate housing. Using this cable on a standard 330500 may compromise the environmental seal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the cable handle exposure to chemicals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable jacket and connector materials are selected for high resistance to moisture and industrial contaminants. When coupled with the 316L stainless steel case of the 330525 sensor, the assembly provides superior protection against the corrosive atmospheres common in mining and chemical processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 25-meter length affect signal accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Bently Nevada piezo-velocity systems are designed to drive signals over significant distances. A 25-meter run is well within the operational parameters, provided the cable is routed away from high-voltage interference sources.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing and Moisture Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo achieve the full NEMA 4X and IP-65 rating, the connector must be properly seated and tightened. In outdoor or wash-down areas, engineers should apply a light coating of silicone lubricant to the connector threads (avoiding the pins) to ensure a gas-tight seal and prevent thread galling over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRouting and Mechanical Stress Relief\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGiven the 25-meter span, the cable must be supported in cable trays or conduits. Avoid tight bends that exceed the minimum bend radius (typically 10 times the cable diameter). At the sensor end, provide a small \"drip loop\" to prevent condensed moisture from traveling down the cable and pooling at the connector interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectromagnetic Interference (EMI) Mitigation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEven with ruggedized shielding, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshould be kept at least 0.3 meters (1 foot) away from high-power AC lines and Variable Frequency Drives (VFDs). If the cable must cross a power line, it should do so at a 90-degree angle to minimize the risk of signal noise.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323332459,"sku":"106765-25","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/106765-25-ecuptpeq1ej_127c5dd4-5d11-493b-9515-aa205caa414c.jpg?v=1765521227"},{"product_id":"bently-nevada-interconnect-cable-16710-10","title":"Bently Nevada Interconnect Cable 16710-10","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 16710-10 Interconnect Cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-quality, shielded and armored cable designed for reliable connections in industrial monitoring systems. It ensures secure signal transmission between sensors, relays, and control devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e3-conductor shielded 22 AWG (0.5 mm²) armored cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne end with 3-socket plug; opposite end with terminal lugs for secure connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable length: 3.0 m (-10 option).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 2 solid-state outputs and a relay with 2 NO circuits, volt-free.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight, robust design for industrial environments; shipping weight: 1.5 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16710-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductors\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded 22 AWG (0.5 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Ends\u003c\/td\u003e\n\u003ctd\u003e3-socket plug at one end, terminal lugs at the other\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m (-10 option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003eRelay with 2 NO circuits, 2 solid-state outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDesigned for connecting Bently Nevada sensors, relays, and monitoring modules. Ensures reliable signal transmission in vibration and condition monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose This Cable\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-10 Interconnect Cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides robust, shielded, and armored connectivity, ensuring signal integrity and long-term reliability in industrial monitoring setups.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668326314347,"sku":"16710-10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16710-10-rdsihpqwtvz_612c7442-b28f-4a5e-ae73-80aa4061c7e1.jpg?v=1765521328"},{"product_id":"bently-nevada-cb2w100-032-interconnect-cable","title":"Bently Nevada CB2W100-032 Interconnect Cable","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCB2W100-032\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada Interconnect Cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-grade, shielded cable assembly designed for reliable signal transfer between proximity system components. Built for demanding industrial environments, it provides stable electrical performance and secure connections for vibration and condition monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMIL-C-5015 two-socket connector with splash-resistant construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePremium shielded twisted-pair cable, 20 AWG conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTeflon® insulated jacket in high-visibility yellow for durability and chemical resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes locking ring, adapter seal, and O-ring for enhanced environmental protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for applications requiring isolated blunt-cut termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized for Bently Nevada monitoring hardware and transducer systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCB2W100-032\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Standard\u003c\/td\u003e\n\u003ctd\u003eMIL-C-5015, 2-socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eIsolated blunt-cut termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003e20 AWG, twisted pair, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003eTeflon®, yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e32 ft (9.75 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd\u003eLocking ring, adapter seal, O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProximity probe and proximitor sensor interconnections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration monitoring systems in turbines, compressors, and rotating machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal wiring in harsh environments requiring EMI shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement or extension cabling for Bently Nevada systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668326904171,"sku":"CB2W100-032","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cb2w100-032-jehmtr1b1cu_cb2891be-73e2-4d3a-9952-bfce65361c34.jpg?v=1765521352"},{"product_id":"bently-nevada-16710-30-interconnect-cable-30-ft","title":"Bently Nevada 16710-30 Interconnect Cable – 30 ft","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable from Bently Nevada is a high-quality 3-conductor shielded cable designed for reliable signal transmission in industrial machinery monitoring systems. Featuring an armored construction with a 3-socket plug at one end and terminal lugs at the other, this cable ensures secure connections for proximity probes, accelerometers, and vibration sensors. With a length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30 ft (9.0 m)\u003c\/strong\u003e, it is ideal for medium-range installations where durability and signal integrity are critical.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3-conductor shielded 22 AWG (0.5 mm²)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable for precise signal transmission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmored design for enhanced protection in harsh industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3-socket plug\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat one end and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eterminal lugs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat the other for reliable connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible length: minimum\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 ft (0.9 m)\u003c\/strong\u003e, maximum\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e99 ft (30 m)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for use with Bently Nevada vibration monitoring and machinery protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight and durable for easy installation and long-term use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-30 Interconnect Cable\u003c\/strong\u003e\u003cspan\u003eis ideal for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting proximity probes, accelerometers, and other monitoring devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial machinery monitoring in power generation, oil \u0026amp; gas, and manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications requiring reliable armored cables with secure terminations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupporting condition-based maintenance and predictive diagnostics programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16710-30\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded 22 AWG (0.5 mm²), armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConne\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3-socket plug at one end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminations\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs at the other end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3 ft (0.9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Length\u003c\/td\u003e\n\u003ctd\u003e99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Option\u003c\/td\u003e\n\u003ctd\u003e30 ft (9.0 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668327035243,"sku":"16710-30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16710-30-j2lbze14wdj_064c47fd-d0bd-4dd4-b363-2e5a9d044156.jpg?v=1765521361"},{"product_id":"bently-nevada-16925-15-interconnect-cable-without-armor-15-ft","title":"Bently Nevada 16925-15 Interconnect Cable without Armor – 15 ft","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 16925-15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable without Armor is designed to provide reliable signal connections in industrial machinery monitoring systems. With a length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e15 feet\u003c\/strong\u003e, it allows flexible installation in tight or standard layouts. Manufactured in the U.S.A., this cable ensures consistent signal integrity and dependable performance for vibration and condition monitoring applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e15 ft (4.57 m) length\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuitable for short- to medium-range installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-armored design for applications where mechanical protection is not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures stable signal transmission between sensors and monitoring equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight and flexible, simplifying routing and installation in industrial setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for connecting Bently Nevada machinery monitoring devices, including proximity probes and vibration sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLinking proximity probes, accelerometers, and vibration sensors to monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse in industrial environments where physical protection of the cable is not critical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery monitoring setups in manufacturing, energy, and process industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort- and medium-range installations requiring reliable, low-cost cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16925-15\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable without Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e15 ft (4.57 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Manufacture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0.131 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668327100779,"sku":"16925-15","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16925-15-beotmfxrifs_252a18b0-dd75-4def-b339-88b90fe2a372.jpg?v=1765521364"},{"product_id":"bently-nevada-16710-32-interconnect-cable-with-armor-32-ft","title":"Bently Nevada 16710-32 Interconnect Cable with Armor – 32 ft","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOvervi\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable with Armor from Bently Nevada is a high-durability cable designed to provide secure and reliable connections in industrial machinery monitoring systems. With a protective armored coating, this cable is ideal for environments where mechanical protection and resistance to external stress are critical. Its 32-foot length offers flexibility for various installation requirements while maintaining signal integrity and protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32 ft\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(9.75 meters) length provides ample reach for industrial installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmored jacket ensures superior protection against abrasion, physical damage, and environmental hazards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for use with Bently Nevada machinery monitoring systems, including proximity probes and vibration sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust construction ideal for harsh industrial environments such as oil and gas, chemical plants, and manufacturing facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure and stable signal transmission even in the most challenging conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis is not\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting proximity probes and vibration sensors to monitoring systems in industrial machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse in manufacturing plants, oil and gas, and power generation facilities requiring robust signal transmission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAny application requiring cable protection against mechanical stress and harsh conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16710-32\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProd\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable with Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e32 ft (9.75 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Type\u003c\/td\u003e\n\u003ctd\u003eArmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668327362923,"sku":"16710-32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16710-32-ddykalvef3s_f3b80414-b43d-4169-81ac-ba2b611d9683.jpg?v=1765521373"}],"url":"https:\/\/www.plcprotech.com\/bg\/collections\/bently-nevada-7200-3300-interconnect-cables.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}