{"title":"Emerson Rosemount","description":"\u003cp\u003eEmerson Rosemount represents the industry benchmark for precision measurement in liquid, gas, and steam applications. The product architecture typically features the patented Coplanar design, as seen in the 3051CD differential and 3051TG gauge pressure transmitters, which integrates a high-stability sensor with advanced microprocessor-based electronics. Technical characteristics include exceptional long-term stability, Power Advisory diagnostics to monitor electrical loop integrity, and various communication protocols such as HART and FOUNDATION Fieldbus. Functionally, Rosemount transmitters provide highly accurate data for process control, safety instrumented systems (SIS), and fiscal metering. Their ruggedized construction and dual-compartment housings ensure reliable performance in extreme temperatures and high-vibration environments across global process industries.\u003c\/p\u003e","products":[{"product_id":"rosemount-8800df120sa1n7d1e1i1m5c4cn7q4q8-8800d-vortex-flowmeter","title":"Rosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8 8800D Vortex Flowmeter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for highly reliable steam, liquid, and gas flow measurement, the \u003cstrong\u003eRosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8\u003c\/strong\u003e is an industrial inline vortex flowmeter utilizing a non-clogging sensor design to eliminate impulse lines and potential leak points. This specific configuration features a massive 12-inch (300 mm) flanged body constructed of robust CF-3M cast stainless steel and 316 wrought stainless steel wetted materials, capable of handling demanding industrial process environments.\u003c\/p\u003e\n\n\u003cp\u003eThe system is equipped with 4-20 mA digital electronics running the HART communication protocol, enabling seamless diagnostic monitoring and configuration. To ensure operator clarity on-site, a high-visibility M5 LCD display is built directly into the rugged stainless steel transmitter housing, which is configured with two M20 x 1.5 conduit entries. For safety compliance, this model comes certified with ATEX dual protection—both Flameproof (E1) and Intrinsic Safety (I1)—and includes comprehensive Q4 calibration and Q8 material traceability documentation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAll-Welded Design:\u003c\/strong\u003e Eliminates internal gaskets, ports, and bypass lines, preventing process bypass and potential leak paths.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdaptive Digital Signal Processing:\u003c\/strong\u003e Provides reliable flow signal tracking while filtering out ambient process vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX Dual Certification:\u003c\/strong\u003e Flameproof and Intrinsic Safety approvals for deployment in classified hazardous industrial zones.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Operator Interface:\u003c\/strong\u003e Includes an integrated M5 LCD indicator showing process variables and diagnostics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable Alarms:\u003c\/strong\u003e Dual NAMUR C4 (high alarm) and CN (low alarm) saturation and alarm values protect process equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuality Documentation:\u003c\/strong\u003e Ships with ISO 10474 3.1\/EN 10204 3.1 calibration and material traceability certificates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-capacity steam utility lines and boiler feedwater monitoring.\u003c\/li\u003e\n  \u003cli\u003eIndustrial gas distribution and compressed air management.\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical process fluid allocation.\u003c\/li\u003e\n  \u003cli\u003ePower plant cooling water and condensate loop measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eRosemount (Emerson)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003e8800DF120SA1N7D1E1I1M5C4CN7Q4Q8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMeter Style\u003c\/strong\u003e\n      \u003ctd\u003eF - Standard flanged body style\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eLine Size\u003c\/strong\u003e\n      \u003ctd\u003e12 inch (300 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWetted Materials\u003c\/strong\u003e\n      \u003ctd\u003eCF-3M Cast Stainless Steel \/ 316 Wrought Stainless Steel (316\/316L)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eFlange Class and Connection\u003c\/strong\u003e\n      \u003ctd\u003eASME B16.5 RF Class 150\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProcess Temperature Range\u003c\/strong\u003e\n      \u003ctd\u003e-40 to +450 degF (-40 to +232 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHousing Material\u003c\/strong\u003e\n      \u003ctd\u003eStainless steel housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConduit Entries\u003c\/strong\u003e\n      \u003ctd\u003eTwo M20 x 1.5 conduit entries\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOutputs\u003c\/strong\u003e\n      \u003ctd\u003e4-20 mA digital electronics (HART Protocol)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCalibration Type\u003c\/strong\u003e\n      \u003ctd\u003eFlow calibration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\n      \u003ctd\u003eATEX Flameproof (E1) \u0026amp; ATEX Intrinsic Safety ia\/ic (I1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDisplay\u003c\/strong\u003e\n      \u003ctd\u003eM5 LCD indicator\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAlarm Configuration\u003c\/strong\u003e\n      \u003ctd\u003eC4 NAMUR high alarm, CN NAMUR low alarm and saturation values\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eQuality Certificates\u003c\/strong\u003e\n      \u003ctd\u003eISO 10474 3.1\/EN 10204 3.1 Calibration (Q4) \u0026amp; Material Traceability (Q8)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDevice Weight\u003c\/strong\u003e\n      \u003ctd\u003e298 lb (135 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eShipping Weight\u003c\/strong\u003e\n      \u003ctd\u003e136 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal \/ Port\u003c\/th\u003e\n      \u003cth\u003eFunctional Assignment\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePWR\/COMM +\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePositive loop power supply input and HART digital communications\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePWR\/COMM -\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNegative loop power supply input and common return\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTEST + \/ -\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLoop current verification terminal (allows measurement without breaking loop)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Ground\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eElectronic housing safety ground termination point\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExternal Ground\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExternal chassis equipotential grounding lug\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStraight Pipe Runs:\u003c\/strong\u003e To ensure accurate flow measurement, install the meter with a minimum of 10 nominal pipe diameters upstream and 5 nominal pipe diameters downstream of straight pipe, free from valves or fittings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e Can be installed in horizontal, vertical, or inclined piping. Vertical mounting with upward process flow is recommended to keep the sensor completely flooded.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Sealing:\u003c\/strong\u003e Install appropriate certified cable glands or conduit seals in the M20 x 1.5 entries to maintain the NEMA 4X \/ IP66\/67 environmental rating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Always ground the transmitter housing to earth using the internal or external grounding screw terminals in accordance with local hazardous area codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eATEX Directive compliance for hazardous area installations.\u003c\/li\u003e\n  \u003cli\u003eFlameproof certification: ATEX II 2 G Ex d IIB+H2 T6 Gb (E1 option).\u003c\/li\u003e\n  \u003cli\u003eIntrinsic Safety certification: ATEX II 1 G Ex ia IIC T4 Ga (I1 option).\u003c\/li\u003e\n  \u003cli\u003eISO 10474 \/ EN 10204 Type 3.1 material and calibration verification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rosemount","offers":[{"title":"Default Title","offer_id":52679230914923,"sku":"8800DF120SA1N7D1E1I1M5C4CN7Q4Q8","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8800df120sa1n7d1e1i1m5c4cn7q4q8-del2yd52gsu_8120ab8a-daa3-49cc-9836-23d9e6ac170a.jpg?v=1765958111"},{"product_id":"1056-01-21-31-an-rosemount-1056-dual-channel-transmitter","title":"1056-01-21-31-AN | Rosemount | 1056 Dual Channel Transmitter","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRosemount 1056-01-21-31-AN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a sophisticated dual-channel multi-parameter transmitter designed for demanding liquid analysis. This specific configuration is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDual Toroidal Conductivity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasurements, allowing for simultaneous monitoring of two separate process lines or the calculation of differential conductivity in high-concentration chemical applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRosemount (Emerson)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1056\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115\/230 VAC, 50\/60 Hz (No Relays)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement 1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eToroidal Conductivity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement 2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eToroidal Conductivity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput \/ Communication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 4-20 mA Analog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 °C (32 to 131 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEMA 4X \/ IP66\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMeasurement Capability\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eToroidal (Inductive) Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for high-conductivity liquids, slurries, or corrosive chemicals that would foul or coat standard contact electrodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Display:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe large, high-contrast LCD displays both measurements simultaneously with user-defined units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAuto-Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter automatically recognizes the measurement boards upon power-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1056 is versatile and can be mounted via panel-mount (1\/2 DIN), pipe-mount, or surface-mount. Ensure the rear cable glands are tightened to maintain the NEMA 4X seal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis unit is configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01 (AC Power)\u003c\/strong\u003e. Internal jumpers or terminal selection must be checked to match your local supply of 115 VAC or 230 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis model requires Toroidal sensors (e.g., Rosemount 222, 225, or 228 series). Ensure the sensor cable is properly shielded and routed away from high-power VFD or motor cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual 4-20 mA outputs are isolated. They can be mapped to represent Conductivity 1, Conductivity 2, or the temperature of either process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQs)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy choose Toroidal conductivity over Contacting conductivity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eToroidal sensors are \"non-contacting.\" They use induction to measure conductivity, making them nearly maintenance-free in applications that involve heavy oils, fibrous slurries, or high-acid\/base concentrations that would corrode standard sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model include alarm relays?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"01\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower option in this specific product code indicates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"no relays.\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf your application requires local high\/low alarm triggers, you must utilize the 4-20 mA signals to an external PLC or DCS, or select a different hardware configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I calibrate the dual channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCalibration is performed through the front-panel membrane keypad. You can perform a \"Zero\" calibration in air and a \"Standard\" calibration using a solution of known conductivity or by comparing it to a grab sample.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the display visible in direct sunlight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 1056 features a high-contrast, black-on-white LCD that is designed for high visibility in both indoor industrial lighting and outdoor daylight conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Rosemount","offers":[{"title":"Default Title","offer_id":52705311719787,"sku":"1056-01-21-31-AN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1056-01-22-32an-3jsjnxijvcz_c4c89031-4c5d-4e1a-aa6e-d22564cd346e.jpg?v=1766639527"}],"url":"https:\/\/www.plcprotech.com\/bg\/collections\/emerson-rosemount.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}