{"title":"Machinery Monitoring","description":"\u003cp\u003eMachinery monitoring systems measure and analyze the condition of rotating assets to detect faults early and support safe, reliable operation. The architecture usually includes sensors such as vibration, proximity, speed, and temperature, signal conditioning, monitoring racks or modules, analysis or protection logic, and communications to DCS, SCADA, or maintenance systems. Technical characteristics include high-resolution sampling, configurable alarm and trip setpoints, channel isolation, time-synchronized trends, and compatibility with common transducers and probe systems. Functional capability covers vibration amplitude and phase monitoring, axial position and speed measurement, alarm and trip handling, diagnostic event capture, and reporting for predictive maintenance. For turbine control and protection contexts, see \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/turbine-machinery-control\"\u003eTurbine \u0026amp; Machinery Control\u003c\/a\u003e. For plant-wide supervisory integration and control infrastructure, reference \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/dcs-control-systems\"\u003eDCS \u0026amp; Control Systems\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-330930-065-01-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-01-05 3300 NSv Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rugged, high-precision proximity transducer link engineered for the industry-leading\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 NSv\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity transducer system. Functioning as a high-integrity signal transmission path, this armored coaxial extension cable connects the specialized NSv proximity probe to the matching Proximitor sensor unit. Extreme operational environments—including oil and gas refineries, petrochemical processing plants, and critical aeroderivative gas turbine installations—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto deliver high-fidelity eddy current telemetry. The module maintains stable impedance profiles when routed through harsh confined spaces to track tight machinery clearances and small-shaft vibrations. By safeguarding low-voltage displacement signals from external radio frequency interference (RFI) and mechanical crushing, this cable guarantees precise data delivery. This continuous monitoring enables safety platforms to stop assets before catastrophic shaft misalignment or bearing wipe happens, effectively eliminating unprogrammed facility downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe ordering structure of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefines its exact mechanical shielding, transmission distance, and hazardous area safety compliance through a fixed modification format:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330930 (Base Model):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the 3300 NSv Coaxial Extension Cable platform tailored for narrow-gap and small-target proximity applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e065 (Cable Length Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfirms an exact physical cable length of 6.5 meters (21.3 feet), calibrated to specific electrical capacitance limits required by the driver module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01 (Connector Protector and Cable Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies an integrated flexible AISI 302 stainless steel armor sleeve outfitted with a high-durability Fluorinated Ethylene Propylene (FEP) outer jacket for maximum chemical and abrasion protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Agency Approval Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishes Multiple Approvals certification, qualifying the assembly for installation within explosive atmospheres and hazardous zones under ATEX and North American standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Benchmarks\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cstrong\u003eHardware Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cstrong\u003eCertified Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e330930-065-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e3300 NSv Proximity Transducer Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eComponent Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eArmored Coaxial Extension Cable with FEP Jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e6.5 meters (21.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eFlexible AISI 302 Stainless Steel (SST)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eOuter Insulation Jacket\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eFluorinated Ethylene Propylene (FEP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e0.220 Ohm\/meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCoaxial Shield Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e0.066 Ohm\/meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eNominal Cable Capacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e69.9 pF\/meter Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eMass Density (with Armor)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e64 g\/meter (0.7 oz\/foot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e-51 to +177 deg C Ambient Temperature Limits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eMinden, Nevada, USA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Telemetry \u0026amp; Mechanical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy must engineers select an exact cable length like the 6.5-meter option for proximity systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEddy current proximity transducer systems operate on strict total system electrical length calculations. The Proximitor sensor evaluates target distance by reading complex high-frequency impedance, which requires a fixed total capacitance. Modifying, cutting, or splicing the 330930-065-01-05 cable alters this baseline capacitance and corrupts the calibration curves, leading to invalid gap readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific protection does the 01 option provide over baseline unarmored coaxial cords?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 01 suffix configuration wraps the inner coaxial trace in flexible AISI 302 stainless steel armor, shielded further by a smooth FEP outer jacket. This setup prevents mechanical flattening or pinching from heavy cabinet doors and machine components while offering total chemical resistance against synthetic lubricants, hot oils, and corrosive industrial solvents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this extension cable maintain reliable telemetry under sub-zero or high-temperature steam environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The entire assembly utilizes advanced FEP insulation layers rated to maintain tight mechanical flexibility and zero dielectric breakdown across a wide operating thermal envelope of -51 to +177 deg C. This makes it highly stable for sub-sea cryogenic pumps as well as high-temperature gas turbine casing enclosures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection and Terminal Boot Alignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen joining the extension cable to the proximity probe lead, ensure the miniature coaxial connectors are clean, completely dry, and free of oily residues. Thread the connections together firmly by hand, avoiding excessive torque that can strip the micro-threads. Once joined, slide the factory connector protection sleeve or self-fusing silicone tape enclosure directly over the junction to seal it from moisture infiltration and prevent accidental grounding against nearby machine metalwork.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radii Rules and Conduit Routing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough the stainless steel armor casing provides excellent crushing protection, field technicians must adhere to standard minimum bend radius guidelines during routing. Avoid tight 90-degree creases or sharp structural edges that can kink the inner center conductor or alter the 69.9 pF\/meter nominal capacitance profile. Route the cable through dedicated, oil-tight flexible conduit paths, keeping the sensor wires separated from heavy high-voltage motor or generator supply lines to mitigate electro-magnetic cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Drainage and Structural Stress Relief:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen passing the 330930-065-01-05 cable through low-lying conduit runs, ensure the enclosure layout incorporates proper low-point drainage loops to prevent pooling fluid or condensation buildup from submerging the connections over long operating periods. Provide adequate strain relief loops at both the machine junction box and the 3500 rack entry plate, ensuring machine casing thermal expansion and high-frequency structural vibration do not pull or stress the cable terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515063147,"sku":"330930-065-01-05","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-01-05-nsv-extension-cable-phqpmgfntm3_c63fea36-3bf4-4a33-85bf-91600e72248c.jpg?v=1765440071"},{"product_id":"bently-nevada-3500-40m-140734-01-proximitor-monitor","title":"Bently Nevada 3500\/40M 140734-01 Proximitor Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 3500\/40M (Part Number: 140734-01) is a high-performance, four-channel machinery protection monitor module built for the 3500 Series Machinery Protection System. The unit accepts continuous analog inputs from various Bently Nevada proximity transducers, conditioning the signals to track critical shaft metrics including radial vibration, eccentricity, thrust position, REBAM, and differential expansion.\u003c\/p\u003e\n\u003cp\u003eThe processed parameters are continuously compared against user-programmable alarm setpoints to execute automated emergency machine trips. The 140734-01 configuration represents the primary internal termination hardware layout, which interfaces the system backplane directly to field sensors. This module provides machinery protection data to plant operators while outputting diagnostic variables to asset management networks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/40M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMain Board Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140734-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor Monitor Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Independent Channels per Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Input Target\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEddy Current Proximity Transducers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Termination Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgrammable Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRadial Vibration, Thrust Position, Eccentricity, REBAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Point Parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Alert levels, 2 Danger levels per active channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Processing Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time continuous analog sampling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOK, TX\/RX, and Bypass Front-Panel LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.6 cm x 25.8 cm x 24.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.80 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eIndustrial turbomachinery maintenance demands tracking precise module part numbers to ensure compatibility with existing rack backplanes and monitoring configurations.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type Designation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/40M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Printed Wire Assembly (PWA) ID:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e140734-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Component Subtype:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor I\/O Module with Internal Termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eHardware Configuration \u0026amp; Engineering Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Pair Configuration Rules\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/40M processes incoming proximity signals using paired channel paths (Channels 1 \u0026amp; 2, and Channels 3 \u0026amp; 4). When assigning functional modes via the 3500 Rack Configuration Software, the programmed choices must follow paired configuration guidelines. For example, you can perform up to two distinct monitoring functions simultaneously across a single pair, provided the underlying transducer sample rates match. Mismatched sensor types on a shared channel pair will cause firmware validation errors during configuration uploads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Termination Field Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the 140734-01 features internal terminations, field sensor extension cables connect directly to the screw terminals on the back of the module.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePreparation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStrip individual wire insulation back exactly 7 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse twisted, shielded three-wire cabling for each probe link (\u003cstrong\u003ePower, Signal, Com\u003c\/strong\u003e) to isolate the system from electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the outer cable shields to the dedicated instrumentation ground bus within the rack enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Replacement Protocol\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/40M module supports hot-swapping while the primary rack remains powered up. However, removing an active monitor module immediately trips the \"OK\" relay and drives dependent channels into an invalid state.\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eChange the rack's physical keylock switch from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"RUN\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnable the software channel\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebypass flags\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtract the faulty 140734-01 board to avoid triggering false emergency machine shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the functional difference between the 3500\/40M and older 3500\/40 monitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"M\" designation denotes enhanced processing capabilities. The 3500\/40M features faster internal signal processing loops, expanded memory registers for transient data logging, and more efficient output of continuous static values to modern control networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which field transducers can be integrated with the 140734-01 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This module is optimized for Bently Nevada 8 mm, 11 mm, and 25 mm Proximitor Transducer Systems. It handles standard 5-meter and 9-meter loop lengths, converting raw gap voltage values into calibrated vibration or position readouts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do the front-panel LEDs assist with diagnostic troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSolid Green \"OK\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNormal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlashing Red \"OK\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal hardware fault or configuration mismatch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlashing Amber \"TX\/RX\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eActive communication across the rack's internal data bus lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515161451,"sku":"3500\/40M 140734-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-40m-140734-01-proximitor-monitor-fzuhngamh0b_6277bb18-daed-4044-bae8-f490e4d427b0.jpg?v=1765440072"},{"product_id":"bently-nevada-330180-90-cn-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-90-CN 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN \u003c\/strong\u003eis a high-grade eddy-current displacement transmitter engineered by Bently Nevada for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evibration monitoring platform. Functioning as the core electronic conditioning driver in a non-contacting transducer circuit, this module converts high-frequency radio frequency fluctuations into a linear voltage output proportional to target movement. Heavy-duty rotating machinery infrastructures—including thermal power generation plants, petrochemical refineries, and continuous mining mills—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto track fluid-film bearing dynamic health. By providing direct backward compatibility for obsolete legacy instrumentation, this sensor monitors shaft vibration and thrust positions accurately. This allows engineering teams to detect structural misalignment early, prevent devastating machine trips, and eliminate unprogrammed production downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe mechanical mounting, total loop tuning, and country-specific safety certifications for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity sensor are systematically categorized through its specific alphanumeric suffix options.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180 Baseline Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the fundamental hardware platform for the high-stability 3300 XL Proximitor Sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-90 System Length Parameter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishes a total calibrated loop system length of 9.0 meters (29.5 feet) configuration optimized exclusively for flat surface panel mounting. The internal oscillator circuit matches the specific impedance profile of a combined 9.0-meter probe and extension cable without field calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-CN Special Approval Token:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates regional country-specific hazardous area certification compliance, satisfying specialized industrial safety standards for deployment across localized high-risk automated areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications \u0026amp; Structural Limits\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMachinery Telemetry Metric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIndustrial Sensor Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-90-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes Business Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Transducer Measurement Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Interfacing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccepts 3300-series 5 mm, 3300 8 mm, and 3300 XL 8 mm Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Block Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremium Grade A308 Die-Cast Aluminum Enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal System Tuning\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 meters (29.5 feet) Shared Loop Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Mounting Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlat Surface Panel Mount Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Output Scale\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) Linear Scaling Vector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Operational Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC Negative Potential Power Supply Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Equipment Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.246 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +100 deg C Extended Ambient Range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +105 deg C Maximum Structural Limits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Compatibility \u0026amp; Diagnostics FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat legacy hardware components does the 330180-90-CN replace within active control racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 330180-90-CN serves as the advanced direct technological upgrade for obsolete legacy components, fully replacing old \u003cstrong\u003e330100-90-02\u003c\/strong\u003e and 330100-90-05 models. It allows seamless drop-in modernization without requiring users to replace existing compatible field probes, preserving infrastructure investments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this specific Proximitor model be supplied with validated manufacturing trace documentation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because this industrial transducer is manufactured in the United States, an official Certificate of Origin (COO) can be integrated into the technical documentation package upon project request, satisfying quality management system tracing and international import parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field probe variations can be connected to the input terminals of this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor contains an adaptive input stage that accommodates a variety of Bently Nevada non-contacting sensors. It operates reliably with traditional 3300-series 5 mm, standard 3300-series 8 mm, or advanced 3300 XL 8 mm proximity probes and matching extension cables arranged in a 9.0-meter total loop configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connector Isolation and Moisture Safeguards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen connecting the proximity probe to the extension cable, shield the coaxial junction completely using high-dielectric silicone sleeve insulation. If the coaxial metal shells touch the machine frame, they will establish secondary ground paths that cause signal distortion. Wrap the completed junction in self-vulcanizing tape to prevent moisture or oil ingress from destabilizing the RF sensor data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Gap Voltage Target Selection and Verification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSet the physical position of the probe tip by tracking the DC gap voltage at the Proximitor terminal points using a calibrated multimeter. Adjust the probe depth inside the machine case until the voltage reads exactly -10.0 VDC, which positions the target directly in the center of the sensor's linear scaling range. Tighten the probe locknut carefully to prevent any shifting during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Paths and Noise Isolation Routing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the power supply lines and signal output loops away from high-voltage motor conductors using twisted, shielded instrumentation cables. Connect the cable shield to the main ground at the machinery monitoring rack terminal block only, cutting the shield clean at the sensor end. This practice prevents ground loop currents from injecting noise into the vibration processing cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515521899,"sku":"330180-90-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-90-cn-proximitor-sensor-w254xy3equw_73962b30-817f-4e70-9998-c31a1f0328f9.jpg?v=1765440079"},{"product_id":"bently-nevada-330180-92-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-92-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-92-05\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a high-precision, eddy-current displacement conditioning device developed by Bently Nevada for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Health Monitoring series. Acting as the core signal processing module within a non-contacting proximity probe circuit, this hardware converts raw radio-frequency (RF) field variations into linear voltage metrics directly proportional to shaft position. Mission-critical industrial assets—including large-scale steam turbine generators in power plants, high-pressure centrifugal compressors in oil refineries, and heavy-duty grinding mills in mining processing sites—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-92-05 (330180-92-05)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto track dynamic fluid-film bearing clearance. By delivering stable, sub-micron vibration and thrust readings directly to a 3500 rack system, this sensor detects structural oil whip or shaft misalignment early. This eliminates unexpected catastrophic machine trips, protects high-cost rotating shafts, and reduces factory unprogrammed downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe exact hardware configuration, total system loop calibration, and hazardous location approval profile of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-92-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity sensor can be systematically decoded through its alphanumeric suffix structure.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180 Product Root:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the fundamental hardware classification for the high-performance 3300 XL Proximitor Sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-92 System Length Option:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDictates a total calibrated loop system length of 9.0 meters (29.5 feet). This parameter ensures the internal oscillator matches the impedance of a 9.0-meter combined probe and extension cable kit without requiring local field recalibration. This option specifically specifies a panel-mount chassis with no specialized DIN-rail mounting hardware included.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05 Multi-Agency Approval Option:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertifies that the module meets strict international hazardous area explosion-proof standards, carrying full, simultaneous CSA, ATEX, and IECEx safety certifications for installation in Zone 0, Zone 1, and Zone 2 explosive environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Standards \u0026amp; Dimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMachinery Protection Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIndustrial Sensor Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-92-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes Business Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Proximity Transducer Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Interfacing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccepts 3300-series 5 mm, 3300 8 mm, and 3300 XL 8 mm Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Structural Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremium Grade A308 Cast Aluminum Shell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Scale Calibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 meters (Total shared probe and cable length)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Scale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) Nominal Linear Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mA to 12 mA Nominal Current Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC Negative Supply Input via Monitor Rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.246 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +100 deg C Extended Ambient Range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +105 deg C Structural Storage Envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Maintenance \u0026amp; Operational FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this 9.0-meter Proximitor sensor operate with a standard 5.0-meter extension cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The internal oscillation matrix of the 330180-92-05 is specifically tuned to match the capacitive and inductive characteristics of a 9.0-meter system. Mixing this module with a 5.0-meter probe and cable kit shifts the resonant frequency, which alters the scale factor from the standard 7.87 V\/mm (200 mV\/mil) and results in incorrect vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific field benefits does the A308 cast aluminum enclosure material provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe premium A308 cast aluminum housing acts as a durable shield that blocks high-frequency electromagnetic interference (EMI) and radio-frequency noise from affecting the internal circuitry. It also provides excellent physical protection against mechanical impacts, atmospheric corrosion, and moisture ingress in harsh compressor deck environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does an electrical technician identify a probe short-circuit versus an open-circuit fault during runtime?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBy measuring the DC gap voltage at the sensor terminal block, field technicians can quickly check system integrity. A reading of 0 VDC or a very low positive value indicates a short-circuit condition, typically caused by a crimped cable trace or a grounded terminal connection. Conversely, a reading that matches the full supply voltage (-24 VDC) indicates an open-circuit fault, pointing to a broken terminal line or a severed probe tip.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connector Insulation and Structural Moisture Guarding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen joining the probe lead to the extension cable inside the machine bracket, the coaxial connection must be completely isolated from the machine frame using high-dielectric silicone sleeves. Moisture or dirt inside this connection can degrade the RF signal, causing immediate measurement drift. Wrap the completed junction in self-fusing vulcanizing tape to keep out moisture on open compressor decks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Alignment and Calibration Benchmarks:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring installation, set the physical probe gap using a digital multimeter connected across the sensor's \"OUT\" and \"COM\" terminal terminals. Rotate the probe body until the DC voltage measures exactly -10.0 VDC, which corresponds to the precise mid-point center of the sensor's linear calibration range. Tighten the probe locknut to the recommended installation torque specification to prevent mechanical drift during high-vibration turbine operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Board Wiring Layout and Noise Isolation Protocols:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the -24 VDC power and signal output loops through high-integrity twisted, shielded instrumentation cables. Ground the cable shields at a single point only, typically at the 3500 monitor rack terminal block, and cut the field shield clean at the sensor end. This grounding technique prevents ground-loop current paths from introducing electrical noise into the vibration monitoring channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515620203,"sku":"330180-92-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-92-05-proximitor-sensor-2qdeihaxoud_6675da58-f3f4-4717-a992-7d62ce7a6bbd.jpg?v=1765440080"},{"product_id":"bently-nevada-330930-065-00-05-3300-xl-nsv-extension-cable","title":"Bently Nevada 330930-065-00-05 3300 XL NSv Extension Cable","description":"\u003ch3\u003e\n    Product Overview\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    The \u003cstrong\u003e330930-065-00-05 (3300 NSv)\u003c\/strong\u003e is a high-performance extension cable specifically engineered for the Bently Nevada 3300 XL NSv (Narrow Side View) Proximity Transducer System. This system is the industry standard for monitoring centrifugal air compressors, refrigeration compressors, and other rotating machinery with extremely tight installation constraints. As a critical link between the NSv probe and the Proximitor Sensor, the \u003cstrong\u003e330930-065-00-05\u003c\/strong\u003e ensures the transmission of high-fidelity displacement signals without impedance mismatch. Its 6.5-meter length is precisely tuned to provide the 200 mV\/mil (7.87 V\/mm) scale factor required for accurate radial vibration and axial position measurements on small-diameter shafts or targets.\n\u003c\/p\u003e\n\n\u003ch3\u003e\n    Suffix Configuration Breakdown\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    According to the official Datasheet 147385, the model \u003cstrong\u003e330930-065-00-05\u003c\/strong\u003e is defined by the following specific engineering options:\n\u003c\/p\u003e\n\n\u003cul class=\"list-paddingleft-2\"\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e065 (Cable Length):\u003c\/strong\u003e 6.5 meters (21.3 feet). This length is typically combined with a 0.5-meter probe to create a 7.0-meter total electrical system.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e00 (Connector Protector and Cable):\u003c\/strong\u003e Standard coaxial cable without stainless steel armor and without connector protectors. This version offers maximum flexibility for routing through dedicated conduit or internal machine housings.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e05 (Agency Approval):\u003c\/strong\u003e Multiple Approvals (ATEX, IECEx, CSA). This certification allows the cable to be used in intrinsically safe (I.S.) applications within hazardous areas globally.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\n    Technical Specifications\n\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003cthead\u003e\n        \u003ctr class=\"firstRow\"\u003e\n            \u003ctd\u003e\n                \u003cstrong\u003eAttribute\u003c\/strong\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n                \u003cstrong\u003eSpecification\u003c\/strong\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e330930-065-00-05\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eBently Nevada\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e3300 XL NSv Proximity Transducer\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eGold-plated Brass ClickLoc\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eJacket Material\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eFluorinated Ethylene Propylene (FEP)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e-52 deg C to +177 deg C (-62 deg F to +351 deg F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e-52 deg C to +177 deg C (-62 deg F to +351 deg F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\n    Engineering FAQs\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eWhy is the NSv extension cable different from standard 3300 XL cables?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    The NSv series is specifically designed for small targets and tight spaces. The electrical characteristics (inductance and capacitance) of the \u003cstrong\u003e330930\u003c\/strong\u003e cable are tuned to match the NSv probe's smaller coil. Mixing NSv cables with standard 8mm probes will result in incorrect vibration readings.\n\u003c\/p\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eWhat is the purpose of the ClickLoc connector?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    The ClickLoc connector is a patented design that prevents the connection between the probe and extension cable from loosening due to machinery vibration. The gold-plating ensures a low-resistance contact that is essential for maintaining the system's precision scale factor.\n\u003c\/p\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eCan I install this cable in an environment with turbine oil?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    Yes, the FEP jacket is highly resistant to turbine oil and most process chemicals. However, since this specific variant (\u003cstrong\u003e-00\u003c\/strong\u003e) does not have a connector protector, you must ensure the connection point is either sealed with the provided silicone tape or located in a dry area to prevent oil from entering the connector.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003e\n    Field Installation and Maintenance Directives\n\u003c\/h3\u003e\n\n\u003cul class=\"list-paddingleft-2\"\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eConnection Integrity:\u003c\/strong\u003e Before connecting the ClickLoc connectors, verify they are clean and dry. Use a lint-free cloth. Do not use pliers to tighten the connectors; they are designed to be finger-tightened until they \"click\" into a locked state.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eBend Radius Constraints:\u003c\/strong\u003e Maintain a minimum bend radius of \u003cstrong\u003e25.4 mm (1 inch)\u003c\/strong\u003e. Sharp bends can damage the internal coaxial shielding and dielectric, leading to \"signal spiking\" or a \"Not OK\" status on the 3500 monitor.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eProper Cable Support:\u003c\/strong\u003e Use high-quality cable ties or clamps to secure the cable every 1 to 2 feet. Ensure that the cable is not under tension at the connector ends. Vibration-induced stress on unsupported cables is a leading cause of premature failure in proximity systems.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eSystem Matching:\u003c\/strong\u003e Always verify that the total length of the probe plus the extension cable matches the configuration of the Proximitor Sensor (e.g., a 7m Proximitor requires a total cable length of 7m). The \u003cstrong\u003e330930-065\u003c\/strong\u003e is part of a 7.0-meter system when used with a 0.5-meter probe.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516275563,"sku":"330930-065-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-00-05-3300-xl-nsv-extension-cable-ullgkoscfm2_2e5685e9-33f6-4078-b646-4488fbee5f5e.jpg?v=1765440087"},{"product_id":"bently-nevada-176449-02-3500-42m-proximitor-seismic-monitor","title":"Bently Nevada 176449-02 3500\/42M Proximitor Seismic Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-02 (3500\/42M)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance four-channel vibration monitor engineered for the Bently Nevada 3500 Machinery Protection System. Designed for critical assets in power generation, oil and gas, and heavy manufacturing, this module accepts inputs from proximity, velocity, and acceleration transducers. Its primary role is to provide continuous machinery protection by cross-referencing live vibration data against user-defined alarm setpoints. By identifying early warning signs of shaft misalignment, bearing wear, or unbalance, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eempowers maintenance teams to execute predictive interventions, effectively eliminating catastrophic machine failures and drastically reducing unscheduled facility downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/42M monitor leverages a dual-pair channel architecture, allowing for versatile monitoring strategies within a single rack slot.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Programming:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannels are configured in pairs (1\/2 and 3\/4), supporting simultaneous functions. For instance, one pair can monitor Radial Vibration while the second pair tracks Thrust Position or Acceleration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatic Value Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module conditions raw transducer signals into actionable parameters such as Direct, Gap, 1X and 2X Vector, Smax, and Eccentricity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiltering Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures programmable single-pole filters (4 Hz to 4000 Hz) and constant Q notch filters for \"Not 1X\" and vector monitoring, ensuring high-fidelity signal conditioning even in noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel coaxial connectors provide short-circuit protected buffered signals for each channel, allowing for direct connection to external frequency analyzers or data collectors without interrupting protection loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e176449-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.7 watts typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kOhm (Standard I\/O)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA (Individual for each channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 600 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to +65 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Hz to 4000 Hz (User-programmable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 241.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eField Service FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the front-panel LEDs signify for system health?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OK LED indicates the internal diagnostics of the 3500\/42M are successful. The TX\/RX LED flashes to confirm active serial communication with the Rack Interface Module (RIM), while the Bypass LED illuminates when the monitor is in Bypass Mode, indicating that alarm logic is inhibited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 3500\/42M monitor process different transducer types simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, because channels are programmed in pairs, you can monitor Proximitor signals on one pair and Seismic (Velocity\/Acceleration) signals on the other pair, provided they are within the supported signal range of -24 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a recorder output is short-circuited?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor operation and protection logic are completely unaffected by short circuits on the 4-20 mA recorder outputs. The module features internal voltage compliance management to maintain signal integrity across its load range.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Installation and Commissioning Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways terminate signal cable shields at the 3500 system I\/O module ground terminals. Never ground the shield at both ends, as this introduces ground loops that can corrupt the sensitive vibration signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor proximity probe applications, verify the \"Gap\" static value during installation. Ensure the probe is gapped within the linear range of the transducer (typically -10 VDC for standard 8 mm probes) to prevent signal clipping and maintain accurate alarm thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the load resistance for the 4-20 mA recorder outputs does not exceed 600 Ohms. Exceeding this limit will result in signal saturation, causing inaccurate reporting to the DCS or PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen using the monitor in high-density rack configurations near the 65 Celsius limit, ensure proper cabinet ventilation. Sustained operation at peak temperatures can degrade the accuracy of the 4-20 mA resolution (from 0.25% at room temp to 0.7% at temperature limits).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516734315,"sku":"3500\/42M 176449-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42m-176449-02-proximitor-seismic-monitor-k32jvb2xqxe_b0d50d43-00a9-4728-9846-a30a23c88b20.jpg?v=1765440095"},{"product_id":"bently-nevada-289837-01-3500-encore-proximitor-seismic-i-o-module","title":"Bently Nevada 289837-01 3500 ENCORE Proximitor\/Seismic I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Proximitor\/Seismic I\/O Module designed specifically for the Bently Nevada 3500 ENCORE Machinery Protection System. This module serves as the critical rear-panel interface for the 3500\/42E Vibration Monitor, facilitating the connection of up to four channels of proximity or seismic transducers. Deployed extensively in power generation, oil and gas, and mining sectors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables the monitoring of vital machinery parameters including radial vibration, thrust position, and eccentricity. By providing reliable signal conditioning and transmission to the main processor, this I\/O module ensures continuous machinery protection and high-fidelity data acquisition. It is an essential component for facilities transitioning from legacy 3300 systems to the ENCORE platform, allowing for modernized vibration monitoring without sacrificing the integrity of field wiring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O module is engineered to support the dual-architecture capabilities of the 3500 ENCORE series, ensuring maximum flexibility for vibration and position monitoring.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFour-Channel Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilized in a standard 3500 ENCORE System Rack, the module supports four independent channels, programmed in pairs (Channels 1 \u0026amp; 2; Channels 3 \u0026amp; 4) to perform specific monitoring functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with a wide array of sensors, including proximity probes for fluid-film bearing measurements and seismic transducers (accelerometers or velocity sensors) for casing vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn a 3500 ENCORE System configuration, the I\/O module interfaces with logic-programmable Relay Modules to drive machinery trip circuits based on user-defined Alert and Danger setpoints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConditioning Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel processes raw transducer signals into \"static values,\" providing operations personnel with real-time machinery health diagnostics for both steady-state and transient conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e289837-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 ENCORE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor\/Seismic I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels (System Mode) \/ 2 Channels (Rack Upgrade)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 percent non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.68 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208.28 mm x 48.26 mm x 127 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 289837-01 be used as a direct spare for 3300 series I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the 3500 ENCORE system is designed to upgrade 3300 monitors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically intended for use in the 3500 ENCORE System Rack. For \"Rack Upgrade\" configurations where the 3300 chassis remains, the system utilizes the pre-existing 3300 series I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this I\/O module support both radial vibration and thrust position simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Since channels are programmed in pairs, you can configure Channels 1 and 2 for radial vibration while Channels 3 and 4 are configured for thrust position (or any other supported function) within the same 3500\/42E monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle signal faults such as a disconnected sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/42E monitor, interfacing through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e, continuously performs self-tests. If a transducer signal fails or field wiring is compromised, the monitor will flag a \"Not OK\" status, preventing false trips and alerting maintenance via the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering and Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting Proximitor or Seismic sensors to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminals, ensure that cable shields are terminated only at the I\/O module ground. Do not ground shields at the transducer end to prevent ground loops, which can introduce noise and compromise vibration measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Torquing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the I\/O module is fully seated into the rear of the ENCORE rack and that the mounting screws are tightened to secure the module against the backplane. This is critical for maintaining signal integrity in high-vibration environments typical of compressor decks or turbine halls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the module is rated for up to 95 percent non-condensing humidity, it should always be installed in a NEMA 4 or IP65 rated enclosure if located in areas with high moisture or corrosive chemicals. Ensure adequate airflow within the rack to maintain the operating temperature below the 65 deg C threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAfter replacing an I\/O module, always use the 3500 Rack Configuration Software to verify that the channel pairings and transducer types match the field-installed sensors. Perform a loop check to ensure that Alert and Danger setpoints are correctly driving the associated Relay Modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516898155,"sku":"3500\/42E 289837-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42e-289837-01-vibration-monitor-5lwybpzw3c4_d9f2ca71-9841-4ea7-b237-17c1fd8f0f71.jpg?v=1765440098"},{"product_id":"bently-nevada-140734-02-3500-42m-proximitor®-seismic-monitor","title":"Bently Nevada 140734-02 3500\/42M Proximitor®\/Seismic Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/42M\u003c\/strong\u003e, designated under spare component assembly \u003cstrong\u003e140734-02\u003c\/strong\u003e, is a four-channel machinery protection hardware instrument designed to process inputs from proximity and seismic transducers. The module acts as an analytical safety layer within the 3500 Machinery Protection System, conditioning analog wave inputs to calculate variables such as radial vibration, thrust position, eccentricity, or velocity, and executing comparisons against user-programmable alarm setpoints. Programmed in paired channel groups through the 3500 Rack Configuration Software, it drives automated alarms when configured safety limits are violated. The hardware supplies individual +4 to +20 mA current recorder loops for each channel to transmit real-time static values directly to distributed control networks and operational archiving servers without interrupting primary protective operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour independent processing channels supporting multiple concurrent vibration and positional function types.\u003c\/li\u003e\n\u003cli\u003eFlexible transducer matching accommodating standard eddy current proximity probes, accelerometers, and velocity sensors.\u003c\/li\u003e\n\u003cli\u003ePairwise channel programming architectures permitting distinct mathematical operations across channel pairs 1-2 and 3-4.\u003c\/li\u003e\n\u003cli\u003eConfigurable Alert and Danger setpoint assignment supporting granular machine safety limits across all calculated static values.\u003c\/li\u003e\n\u003cli\u003eIndividual, front-panel coaxial buffered transducer connections engineered with short-circuit protection for structural diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial steam turbine rotor shaft radial vibration tracking and thrust position observation.\u003c\/li\u003e\n\u003cli\u003eLarge-scale centrifugal gas compressor casing seismic velocity monitoring and mechanical trip protection.\u003c\/li\u003e\n\u003cli\u003ePower generation gas turbine shaft absolute vibration and rotor eccentricity monitoring.\u003c\/li\u003e\n\u003cli\u003eHeavy industrial fluid pump rolling element bearing health analysis using specialized REBAM logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/42-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor® Seismic Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: I\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eProx\/Seismic I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eProx\/Seismic I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eTMR Prox\/Seismic I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Barriers (4 x prox.\/accel. ch's) and Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Barriers (2 x prox.\/accl. + 2 x Velomitor® channels) and Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Barriers (4 x Velomitor® channels) and Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003eShaft Absolute I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eShaft Absolute I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e09\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C (Class 1, Div 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX\/CSA (Class 1, Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e140734-02\u003c\/td\u003e\n\u003ctd\u003e3500\/42M Proximitor®\/Seismic Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140734-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 to 4 proximity, velocity, or acceleration transducer signals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ for Proximitor and Acceleration inputs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBussed TMR Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kΩ effective impedance with 3 channels wired in parallel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.7 Watts typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel Status Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOK LED, TX\/RX LED, Bypass LED \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 short-circuit protected coaxial connectors (1 per channel) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Current Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA DC individual loop per channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Voltage Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc range across load \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Load Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 600 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bit Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3662 µA per bit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Update Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms or less \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThrust\/Diff. Expansion Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect filter: -3 dB at 1.2 Hz | Gap filter: -3 dB at 0.41 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatic Value Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.33% of full-scale typical, ±1% maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Setpoint Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin 0.13% of the desired value \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlert Alarm Delay Scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 60 seconds in 1 second intervals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDanger Alarm Delay Scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 seconds or 1 to 60 seconds in 0.5 second intervals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp (Standard I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 Celsius to +65 Celsius (-22 Fahrenheit to +150 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp (Barrier I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Celsius to +65 Celsius (32 Fahrenheit to +150 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to +85 Celsius (-40 Fahrenheit to +185 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% noncondensing relative humidity \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight (Non-barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight (Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 91.1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Allocation Footprint\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot and 1 full-height rear slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Connector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel Coaxial Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protected buffered output for dynamic signal diagnostics \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx\/Seismic I\/O Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear interface wire blocks for direct internal termination sensor hookups \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Termination Headers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated multi-pin headers interfacing to standalone terminal blocks \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated loop connection points for +4 to +20 mA proportional telemetry \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNoise Suppression: Ensure sensor shielding parameters are thoroughly maintained by tying instrumentation ground wires to the specified chassis ground points on the I\/O block to limit electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eAlignment Mapping: Confirm that the main card assembly \u003cstrong\u003e140734-02\u003c\/strong\u003e slides cleanly along the guide tracks of the front rack slot, seating firmly into the rear data backplane lines.\u003c\/li\u003e\n\u003cli\u003eTermination Rules: Never mix external termination blocks with I\/O modules explicitly designed and coded for internal termination applications.\u003c\/li\u003e\n\u003cli\u003eSpace Allotment: Maintain clear tracking lines on both the forward and rear margins of the chassis rack frame to promote unrestricted ambient airflow through the module housings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Low-Voltage Directives: EN61010-01 safety requirements for industrial monitoring equipment.\u003c\/li\u003e\n\u003cli\u003eEMC Emissions Shielding: Certified under IEC\/EN 61000-6-4 and EN 55011 Class A standards.\u003c\/li\u003e\n\u003cli\u003eEMC Susceptibility Criteria: Meets EN 61000-4-2 Electrostatic Discharge (Criteria B) and EN 61000-4-3 Radiated Susceptibility (Criteria A).\u003c\/li\u003e\n\u003cli\u003eHazardous Area Approvals: CSA\/NRTL\/C Class I, Division 2, Groups A, B, C, D (T4 rating at Ta = -30 Celsius to +65 Celsius).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this component function as an absolute overspeed machinery shutdown mechanism?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this device is explicitly designed to handle dynamic proximitor and seismic acceleration\/velocity metrics rather than the high-frequency speed wheel edge triggers needed for deterministic overspeed protection loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the underlying distinction between the 3500\/42M designation and part number 140734-02?\u003c\/strong\u003e A: The 3500\/42M reflects the official overall functional system monitor series classification, whereas the code 140734-02 governs the exact ordering catalog number for the internal replacement main circuit board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Will an unexpected short circuit across the +4 to +20 mA recorder loop disrupt machinery protection?\u003c\/strong\u003e A: No, the analog current loop circuitry is internally isolated, meaning the processing logic, monitor functionality, and protective safety alarms continue operating normally if a field recorder loop shorts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it possible to program channel 1 to calculate radial vibration while channel 2 evaluates thrust position?\u003c\/strong\u003e A: No, monitoring channels are configured software-wise in distinct functional pairs, meaning channels 1 and 2 must execute the same baseline behavioral function, while channels 3 and 4 can handle another.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the front panel indicators if the module experiences an internal processing error?\u003c\/strong\u003e A: The green OK LED will drop out of its constant illuminating status, signaling a hardware exception condition and initiating a safe system bypass state to avoid false over-limit trips.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517717355,"sku":"3500\/42M 140734-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42m-140734-02-proximitor-seismic-monitor-pwa-r0numhbecec_3ab792c9-f156-41de-b90f-53ed4538fa1b.jpg?v=1765440108"},{"product_id":"bently-nevada-176449-03-3500-44m-aeroderivitive-gt-vibration-monitor","title":"Bently Nevada 176449-03 3500\/44M Aeroderivitive GT Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/44M\u003c\/strong\u003e, full spare part assembly number \u003cstrong\u003e176449-03\u003c\/strong\u003e, is a four-channel machinery hardware instrument specifically engineered for aeroderivative gas turbine vibration processing. The module operates as a dedicated technical subsystem within the 3500 Machinery Protection System, acquiring signals directly from Velomitor velocity sensors and dynamic accelerometers through specialized external interface hardware. It continuous performs algorithmic comparisons of real-time machine health indices against user-programmable alarm limits to drive localized protective relays. Utilizing the 3500 Rack Configuration Software, the component supports multi-mode logic handling up to eight individual profiles of alert and danger limits per channel, adapting instantaneously to active engine loading states via hardware contact inputs or communications gateway buses. Integrated signal tracking filters accept dual independent Keyphasor references, ensuring exact synchronous 1X amplitude tracking and wide band-pass tracking across variable-speed turbine shafts.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour input channels optimized for low-noise high-frequency aeroderivative gas turbine casing vibration tracking.\u003c\/li\u003e\n\u003cli\u003eDual Keyphasor input assignment enabling separate tracking filter options per channel pair.\u003c\/li\u003e\n\u003cli\u003eMulti-mode channel functionality storing up to eight distinct sets of alert, danger, and time delay matrices.\u003c\/li\u003e\n\u003cli\u003eInternal signal integration logic translating raw acceleration values into velocity metrics without external hardware.\u003c\/li\u003e\n\u003cli\u003eFront-mounted coaxial buffered output points allowing unconditioned sensor wave capture via diagnostic analyzers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAeroderivative gas turbine aviation-derivative generator drive package casing vibration tracking.\u003c\/li\u003e\n\u003cli\u003eHigh-speed industrial mechanical drive turbine rotor vibration and synchronous 1X shaft tracking.\u003c\/li\u003e\n\u003cli\u003eGas transmission pipeline compressor station multi-mode emergency shutdown protection.\u003c\/li\u003e\n\u003cli\u003ePeak-load power station gas turbine fast-start monitoring and dynamic mode adaptation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/44M-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAeroderivitive GT Vibration Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: I\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C (Class 1, Div 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX\/IECEx\/CSA (Class 1, Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e176449-03\u003c\/td\u003e\n\u003ctd\u003e3500\/44M Aeroderivitive GT Vibration Monitor Main Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/44M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e176449-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccelerometers, Velomitor sensors, proximity probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.7 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ (Prox\/Velom I\/O type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Integration Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.33% of full-scale typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1X Vibration Tracking Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 Hz to 4000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBand-pass Frequency Scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 10 kHz standard configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Transducer Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel coaxial BNC connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Delay Intervals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable from 0.1 to 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 Celsius to +65 Celsius (-22 Fahrenheit to +150 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to +85 Celsius (-40 Fahrenheit to +185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Monitor Card Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Terminal Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Monitor Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.2 mm x 24.4 mm x 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Space Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot and 1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNoise Minimization: Route the incoming Velomitor or accelerometer signal pairs through shielded twisted cabling, clamping the copper ground shield braid only at the rear I\/O card common chassis points.\u003c\/li\u003e\n\u003cli\u003eModule Positioning: Slide the main card assembly \u003cstrong\u003e176449-03\u003c\/strong\u003e into the front slot of the 3500 chassis basket directly across from its matching rear termination interface block.\u003c\/li\u003e\n\u003cli\u003eMode Pin Terminations: When utilizing multi-mode function profiles, ensure the external switching contacts are connected using dry voltage-free loops to the designated I\/O terminal block.\u003c\/li\u003e\n\u003cli\u003eThermal Protection: Verify that the chassis fan assemblies remain unobstructed to avoid hot spots along high-density four-channel monitor installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow Voltage Directive: EN 61010-1 Electrical and Safety requirements for hardware tracking.\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: EN 61000-6-2 Industrial Susceptibility and EN 61000-6-4 Industrial Emissions criteria.\u003c\/li\u003e\n\u003cli\u003eHazardous Area Approvals: CSA Class I, Division 2, Groups A, B, C, and D ratings under option code 01.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this component interface directly with high-temperature acceleration sensors without any auxiliary hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, standard accelerometers or high-temperature casing probes require matching external charge amplifiers or external interface sub-modules before the terminal block links to the monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the physical structural difference between model 3500\/44M and component 176449-03?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 3500\/44M defines the full aeroderivative monitoring product family catalog code, while 176449-03 specifies the direct warehouse replacement part number for the main processing card alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the internal multi-mode tracking architecture execution operate when a turbine shifts load?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The monitor samples external dry contact statuses or software network words, matching the live operational stage of the turbine engine to immediately step into one of the eight separate user-defined alert and danger alarm sets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it possible to configure this unit without a dedicated Keyphasor speed loop reference card in the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, basic wide band-pass filtering operations can operate independently, but synchronous 1X shaft tracking requires active Keyphasor reference signals delivered through the rack internal backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Will an instrumentation line fault across one transducer impact the data analysis performance of the other three channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, individual processing pathways inside the module isolate faulty field lines, so an active fault on channel 1 will drop its specific OK LED status without disturbing adjacent channel metrics.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517782891,"sku":"3500\/44M 176449-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-44m-176449-03-vibration-monitor-s53vd2uwauz_7c4df997-9084-4cff-82ad-f52739bb4f25.jpg?v=1765440109"},{"product_id":"bently-nevada-330930-065-03-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-03-05 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-065-03-05\u003c\/strong\u003e: 3300 NSv extension cable configuration specified by a 6.5-meter length (Option 065), unarmored cable construction with integrated connector protector (Option 03), and multiple hazardous area approvals (Option 05).\u003c\/p\u003e\n\u003cp\u003eThis 75-ohm coaxial \u003cstrong\u003e3300 NSv Extension Cable\u003c\/strong\u003e acts as the electrical link between a 3300 NSv proximity probe and a 3300 XL NSv Proximitor Sensor (Model 330980). It transmits high-frequency eddy-current signals to monitor radial shaft vibration, axial position, and speed in industrial rotating machinery with limited target geometry. The unarmored design provides maximum routing flexibility through protective conduit systems, while the pre-installed connector protector prevents fluids, turbine oils, and moisture from compromising the connection junction.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 065 specifies a 6.5-meter (21.3 feet) overall cable length.\u003c\/li\u003e\n  \u003cli\u003eOption 03 designates an unarmored coaxial construction that includes a factory-installed fluorosilicone connector protector on the female connector.\u003c\/li\u003e\n  \u003cli\u003eOption 05 offers multiple international certifications for intrinsically safe and non-incendive installation.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc miniature coaxial connectors ensure reliable high-frequency signal transmission and mechanical locking.\u003c\/li\u003e\n  \u003cli\u003eMinimum bend radius of 25.4 mm (1.0 inch) permits tight cable routing inside machinery casings and conduit networks.\u003c\/li\u003e\n  \u003cli\u003eCompatible with 3300 XL NSv proximity probes and Proximitor sensors to form a calibrated transducer system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAeroderivative gas turbines\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressors and high-speed turbomachinery with limited target area or tight clearance\u003c\/li\u003e\n  \u003cli\u003eRadial shaft vibration and axial position measurement in small-bore rotating machinery\u003c\/li\u003e\n  \u003cli\u003eEnclosed industrial gearboxes and high-speed pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330930-065-03-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable, 6.5 meters, unarmored, with connector protector, multiple approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length\u003c\/td\u003e\n      \u003ctd\u003e065\u003c\/td\u003e\n      \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector and Cable\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eWithout stainless steel armor, with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, and IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-065-03-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75-ohm coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (Unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded (fluorosilicone material on female connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.220 ohms\/meter (0.067 ohms\/foot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShield Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.066 ohms\/meter (0.020 ohms\/foot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExtension Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/meter (21.3 pF\/foot) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 inch)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System (330900 series probes and 330980 Proximitor Sensor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfirm that the combined length of the extension cable (6.5 m) and the matching probe equals the total calibrated length required by the Proximitor Sensor (typically 7.0 m system length).\u003c\/li\u003e\n  \u003cli\u003eEnsure ClickLoc connectors are only finger-tightened during installation. The maximum allowable connection torque is 0.56 N m (5 in lb). Do not use metallic tools or pliers.\u003c\/li\u003e\n  \u003cli\u003eMaintain a routing bend radius of no less than 25.4 mm (1.0 inch) to prevent damage to the inner coaxial conductor and shield.\u003c\/li\u003e\n  \u003cli\u003eVerify that the fluorosilicone connector protector is correctly seated over the probe-to-cable junction to shield the contacts from external turbine oil and moisture.\u003c\/li\u003e\n  \u003cli\u003eInstall the extension cable in accordance with the appropriate regional hazardous area control drawings (Bently Nevada drawing 141092 for intrinsically safe or drawing 140979 for non-incendive layouts).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American (cNRTLus):\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, and D (intrinsically safe when installed with approved barriers); Class I, Zone 2: AEx\/Ex nA\/ec IIC T4\/T5 Gc (non-incendive)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc; Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517946731,"sku":"330930-065-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-03-05-cable-extension-module-dj3putae3wr_e6f0dc8b-5aa7-4490-868d-050f8f816560.jpg?v=1765440113"},{"product_id":"bently-nevada-330180-91-00-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-91-00 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-91-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e configured for a 9.0 m system length, featuring a 35 mm DIN rail mounting plate, and supplied with no agency approvals. This sensor operates by conditioning and driving the signal from an eddy-current proximity probe, translating physical shaft displacement into a proportional DC voltage signal for monitoring system inputs.\u003c\/p\u003e\n\n\u003cp\u003eThis variant differs from the panel-mount configurations (such as Option 90) by utilizing a DIN-mount base that occupies a narrower 35.1 mm slot, allowing for high-density mounting in protective enclosures. While other configurations include hazardous area approvals (such as Option 05), this configuration (Option 00) is for general-purpose environments where agency listings are not required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 91 specifies a 9.0-meter electrical system length matched to 3300 XL 8 mm probes and extension cables.\u003c\/li\u003e\n  \u003cli\u003eDIN-rail mounting base provides electrical isolation from the mounting surface.\u003c\/li\u003e\n  \u003cli\u003eOption 00 specifies a configuration without hazardous area agency approvals.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass or gold-plated beryllium copper connectors provide secure signal paths.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal strips facilitate field wiring without screw-clamping mechanisms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration measurement on steam and gas turbines, compressors, motors, and pumps.\u003c\/li\u003e\n  \u003cli\u003eAxial position monitoring of rotating shafts in industrial machinery.\u003c\/li\u003e\n  \u003cli\u003eNon-contacting eddy-current displacement monitoring in industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330180-91-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, 9.0 m system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption A - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e91\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption B - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required (No agency approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-91-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (Not required)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one non-contacting 3300 XL 8 mm Proximity Probe and Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Housing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA308 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 35.1 mm x 89.4 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.246 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eWiring Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003ePower Supply input (-24 Vdc nominal)\u003c\/td\u003e\n      \u003ctd\u003eAccepts 0.2 to 1.5 mm2 (16 to 24 AWG) conductor sizes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eSystem Common (Return path)\u003c\/td\u003e\n      \u003ctd\u003eAccepts 0.2 to 1.5 mm2 (16 to 24 AWG) conductor sizes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eProportional voltage output signal\u003c\/td\u003e\n      \u003ctd\u003eAccepts 0.2 to 1.5 mm2 (16 to 24 AWG) conductor sizes\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the module onto a standard 35 mm DIN rail. Ensure there is a minimum clearance of 3.05 mm above the device to allow easy removal from the DIN rail.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use a 3-conductor shielded triad cable for connecting the sensor output to the monitoring system. Keep the maximum cable run length below 305 meters (1,000 feet).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Strips:\u003c\/strong\u003e Utilize the SpringLoc terminal strips for fast, secure connections without screw-tightening. Stripped wire leads insert directly into the terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e The integral mounting pad provides absolute electrical isolation from the DIN rail. No additional external isolator plates are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility (EMC):\u003c\/strong\u003e Complies with European Union Directive 2014\/30\/EU standards including EN 61000-6-2 and EN 61000-6-4.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestriction of Hazardous Substances (RoHS):\u003c\/strong\u003e Complies with Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e Certified to SIL 2 (HFT = 0) and SIL 3 (HFT = 1) limits when used within a qualified safety instrumented system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approval:\u003c\/strong\u003e None (Option 00 is specified for general-purpose, non-hazardous areas).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518897003,"sku":"330180-91-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-91-00-5-8-mm-proximitor-sensor-rcdw0doug3q_b421d6f1-53db-40f9-9769-1c1febddd9f7.jpg?v=1765440123"},{"product_id":"bently-nevada-330180-90-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-90-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 90 (9.0 meters system length, panel mount) and Option 05 (CSA, ATEX, IECEx approvals) specify this 3300 XL Proximitor Sensor configuration — \u003cstrong\u003e330180-90-05\u003c\/strong\u003e. This non-contacting sensor is a core conditioning module for Bently Nevada 3300 XL proximity transducer systems, which are used to measure radial shaft vibration, axial thrust position, and speed on rotating industrial machinery. The unit houses specialized oscillator and demodulator circuitry that generates a radio frequency signal, drives the connected eddy-current probe, and conditions the returning signal into a continuous analog voltage proportional to the dynamic gap distance.\u003c\/p\u003e\n\n\u003cp\u003eThis panel-mount variant features a standardized 4-hole mounting plate that shares an identical footprint with older Proximitor designs, simplifying legacy upgrades. The aluminum mounting base provides built-in electrical isolation, removing the requirement for separate isolator plates. Calibrated for 9.0-meter systems, the 330180-90-05 requires precise matching with a 3300 XL 8 mm proximity probe and extension cable that sum to a total physical length of exactly 9.0 meters. Option 05 compliance adds certified protection for hazardous locations, enabling safe deployment under global intrinsic safety and non-sparking\/non-incendive standards.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 90 configuration specifies a 9.0-meter system length calibration matched for 4-hole panel mounting.\u003c\/li\u003e\n  \u003cli\u003eOption 05 agency approval delivers certified safety for hazardous locations under CSA, ATEX, and IECEx approvals.\u003c\/li\u003e\n  \u003cli\u003eStandardized panel-mount footprint provides backwards compatibility with legacy Bently Nevada Proximitor sensors.\u003c\/li\u003e\n  \u003cli\u003eIntegrated electrical isolation on the mounting base eliminates the need for separate isolator hardware.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal block connectors provide secure field wiring connections without requiring special installation tools.\u003c\/li\u003e\n  \u003cli\u003eAdvanced RF\/EMI immunity satisfies European CE standards without requiring specialized shielded conduit or metallic enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and dynamic positioning measurements on high-speed turbines, compressors, and pumps.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position and shaft eccentricity monitoring in power generation and petrochemical applications.\u003c\/li\u003e\n  \u003cli\u003eContinuous speed and tachometer input conditioning on industrial motors, generators, and fans.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection monitoring loops connected to Bently Nevada 3500 Series racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330180-90-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, 9.0 m system length, panel mount, hazardous area approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption A - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, panel mount configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption B - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals (Intrinsically Safe \u0026amp; Non-Incendive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-90-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePanel mount (4-hole footprint)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (nominal -24 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Signal Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog negative voltage (-1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), from 0.25 mm to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-6.5%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Field Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 meters (1000 feet) of 3-conductor shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 61.0 mm x 50.8 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e246 g (0.246 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon reference \/ system ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog voltage output signal (-1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the Proximitor sensor on a clean, flat surface using the integrated panel-mount base; the mounting base provides integral electrical isolation directly.\u003c\/li\u003e\n  \u003cli\u003eUse tinned 3-conductor shielded triad field wiring cable with wire sizes ranging from 0.2 mm2 to 1.5 mm2 (16 AWG to 24 AWG).\u003c\/li\u003e\n  \u003cli\u003eInsert wires directly into the SpringLoc terminal strip; no special insertion or clamping tools are required.\u003c\/li\u003e\n  \u003cli\u003eLimit total field wiring between the Proximitor sensor and the monitoring system to a maximum of 305 meters (1000 feet) to prevent high-frequency signal roll-off.\u003c\/li\u003e\n  \u003cli\u003eEnsure that probe and extension cables maintain a minimum bend radius of 25.4 mm (1.0 inch) during routing.\u003c\/li\u003e\n  \u003cli\u003eFor hazardous locations, follow the certified wiring diagrams for intrinsically safe or non-incendive\/non-sparking requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Immunity for Industrial Environments), EN 61000-6-4 (Emissions for Industrial Environments)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e CE mark, RoHS Directive 2011\/65\/EU, China RoHS compliance (EFUP 15 years)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (Hardware Fault Tolerance HFT = 0), SIL 3 capable in redundant (HFT = 1) systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 05):\u003c\/strong\u003e CSA, ATEX, and IECEx certifications for intrinsically safe (ia) and non-incendive\/non-sparking (nA, ec) installations in Class I, Division 1\/2 and Zone 0\/2 hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519060843,"sku":"330180-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-90-05-3300xl-5-8-mm-proximitor-sensor-fiezfwww3ne_ce9ec8c7-1922-48ed-8e3a-ab4d790e2b9b.jpg?v=1765440127"},{"product_id":"bently-nevada-330930-045-01-00-3300-nsv-extension-cable","title":"Bently Nevada 330930-045-01-00 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330930-045-01-00\u003c\/strong\u003e is a \u003cstrong\u003e4.5-meter (14.8 feet) 3300 NSv Extension Cable\u003c\/strong\u003e engineered to provide precise signal path connectivity within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This unit is specifically configured for mid-range distance requirements where standard 4.0m or 5.0m cabling options create excessive or insufficient slack, necessitating a more exacting cable run in complex machinery cabinets.\u003c\/p\u003e\n\u003cp\u003eThis specific model utilizes a ruggedized architecture featuring \u003cstrong\u003eAISI 302 stainless steel armor\u003c\/strong\u003e without an FEP outer jacket. This construction balances physical durability—protecting the coaxial core against localized mechanical abrasions—with the necessary flexibility required for tight-radius routing inside compressor skids or turbine enclosures. It serves as a vital bridge in systems where the Proximitor Sensor is located in a protected, remote junction box away from the primary measurement point, ensuring that low-level eddy-current signals remain shielded from localized electromagnetic noise.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4.5m Length Precision:\u003c\/strong\u003e Provides an intermediate length option to optimize cable management and minimize signal attenuation in custom-configured monitoring loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless Steel Armor Protection:\u003c\/strong\u003e Includes flexible AISI 302 stainless steel armor, enhancing crush resistance and shielding against sharp installation edges without the additional bulk of an outer FEP jacket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Stability:\u003c\/strong\u003e Optimized to maintain linear signal response (voltage-to-gap) across the extended 4.5m span, critical for phase-sensitive applications like Keyphasor signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Mechanical Integrity:\u003c\/strong\u003e Equipped with field-proven, gold-plated brass ClickLoc connectors that provide a secure, vibration-proof latch, preventing signal intermittent behavior caused by connector fretting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Field Integration:\u003c\/strong\u003e Fully compliant with existing 3300 NSv hardware, allowing for easy integration into high-density probe arrays where routing space is at a premium.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Compressor Monitoring:\u003c\/strong\u003e Radial vibration and thrust position sensing on small-shaft turbomachinery where the sensor housing must be displaced by exactly 4.5 meters from the probe tip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced OEM Skids:\u003c\/strong\u003e Integration into pre-engineered compressor skids that demand specific, standardized cable lengths to ensure consistent signal timing across multiple machine trains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Routing in Dense Conduits:\u003c\/strong\u003e Deployment in cable-crowded environments where armored protection is essential for cable longevity, yet the absence of a bulky FEP jacket is preferred for improved pull-through performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Array Synchronization:\u003c\/strong\u003e Managing phase reference signal paths in multi-probe tachometer systems requiring balanced cable lengths to avoid phase synchronization errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330930-045-01-00\u003c\/strong\u003e model identifier reflects the following technical configuration:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e045\u003c\/td\u003e\n\u003ctd\u003e4.5 meters (14.8 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Connector \u0026amp; Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eWith stainless steel armor, no FEP jacket, no connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot Required \/ Standard Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohms coaxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible AISI 302 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass (ClickLoc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 N (50 lb) max rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Core\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-grade coaxial with FEP insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Verification:\u003c\/strong\u003e Verify that the 3300 XL NSv Proximitor Sensor is configured for a 4.5m extension cable length (often part of a 5.0m or 7.0m total system calibration) to ensure measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmor Handling:\u003c\/strong\u003e When routing the stainless steel armored cable, ensure the armor ends are properly seated to prevent fraying and to maintain the electrical continuity of the shield path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Engagement:\u003c\/strong\u003e Use manual pressure to lock the ClickLoc connectors until a distinct click is felt. Do not apply thread-locking compounds to the connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Radius Maintenance:\u003c\/strong\u003e Maintain at least a 25.4 mm bend radius. Excessively tight bends may deform the coaxial core, causing local impedance mismatches that manifest as \"noise\" in the vibration data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e Designed to withstand industrial electromagnetic environments (EN 61000-6-2\/4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS\/China RoHS:\u003c\/strong\u003e Environmentally compliant with international hazardous substance directives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e Components are designed to support SIL-rated safety instrumented systems (SIS) when used with appropriate certified Proximitor modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519585131,"sku":"330930-045-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-045-01-00-3300-nsv-extension-cable-lepbil1xp11_512bcc11-8952-40ec-a08d-3f2fca984530.jpg?v=1765440136"},{"product_id":"bently-nevada-330180-51-00-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-51-00 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-51-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e configuration featuring a 5.0-meter system length compatibility and an integrated DIN-rail mounting base. This specific variant is specified with the 00 option code, indicating that it does not carry hazardous area agency approvals. The device houses the high-frequency oscillator and demodulator circuitry necessary to condition raw displacement data from a compatible 3300 XL 8 mm proximity probe and extension cable. It converts the physical gap between the probe tip and the target material into a continuous, linear analog voltage output proportional to shaft movement.\u003c\/p\u003e\n\u003cp\u003eBy pairing the sensor with a 5.0-meter total system length probe and extension cable, the measurement system maintains its linear calibration across a full 2.0 mm (80 mils) dynamic range. The integrated mounting base of this variant provides built-in electrical isolation, preventing ground loops and eliminating the need for separate isolator plates. The spring-loaded terminal strips provide secure field-wiring connections without requiring manual screw-type clamping.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 51 specifies compatibility with a 5.0-meter total system length and incorporates a 35 mm DIN-rail mount.\u003c\/li\u003e\n\u003cli\u003eOption 00 designates a standard build where special hazardous area certifications are not required.\u003c\/li\u003e\n\u003cli\u003eIntegrated SpringLoc terminal strips facilitate field-wiring installations without specialized tooling.\u003c\/li\u003e\n\u003cli\u003eIsolating mounting base prevents electromagnetic interference and ground-loop noise.\u003c\/li\u003e\n\u003cli\u003eBroad compatibility with standard 3300 XL 8 mm proximity probes and extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis Proximitor sensor is used for machinery vibration, position, and shaft keyphasor measurements in standard industrial environments. Typical installations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam, gas, and hydro turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating process compressors\u003c\/li\u003e\n\u003cli\u003eHigh-speed industrial pumps and gearboxes\u003c\/li\u003e\n\u003cli\u003eLarge electric motors and generator shaft bearings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-51-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor, 5.0 meters, DIN-rail mount, standard approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Total Length \u0026amp; Mounting Option\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet) system length, DIN-rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number \/ SKU\u003c\/td\u003e\n\u003ctd\u003e330180-51-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail mount (Option 51)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capability\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300-series 5 mm or 3300 XL 8 mm proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Sensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) over linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), starting approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc; 12 mA maximum current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohms nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Strip Support\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wiring Distance\u003c\/td\u003e\n\u003ctd\u003e305 meters (1000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e89.4 mm x 81.3 mm x 61.0 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Label\u003c\/th\u003e\n\u003cth\u003eConnection Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eAnalog displacement signal output to monitoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSystem common \/ signal ground reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT\u003c\/td\u003e\n\u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the mounting base is locked onto a standard 35 mm DIN rail. Provide a minimum of 3.05 mm (0.120 inches) of vertical clearance above the housing to facilitate standard removal from the rail. Use three-conductor shielded triad cables for field wiring to connect terminals to the monitor. Keep field wiring within the maximum distance limit of 305 meters (1000 feet) to prevent output signal attenuation.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Standard\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003ctd\u003eComplies with European electromagnetic compatibility (EMC) standards without special shielded conduit or housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519781739,"sku":"330180-51-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-51-00-3300-xl-proximitor-sensor-proximity-switch-24ni1ysosth_23365f6d-1973-456e-ab2a-a90ed88b27f2.jpg?v=1765440141"},{"product_id":"bently-nevada-330101-40-60-05-02-cn-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-40-60-05-02-CN 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-40-60-05-02-CN\u003c\/strong\u003e is a high-precision, unarmored \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e belonging to the industry-standard 3300 XL series of eddy-current transducer systems. This specific configuration features a 3\/8-24 UNF threaded body, an extended 4.0-inch unthreaded length, a 6.0-inch overall case length, and a 0.5-meter (1.6 feet) total cable length terminated with a standard miniature coaxial ClickLoc connector. Certified under the -CN China hazardous area approval package, this probe is specifically marked and certified with NEPSI and CCC approvals for hazardous industrial zones in China. It is designed to perform non-contact shaft vibration, position, and displacement measurements on critical rotating machinery operating in demanding environments.\u003c\/p\u003e\n\u003cp\u003eCompared to armored or shorter-case variants, this unarmored configuration offers excellent flexibility for installations where probe casing protection is provided by a mounting sleeve or conduit, and where deep insertion into machine housings is required. The 0.5-meter cable is optimized for coupling with a 3300 XL extension cable in 5-meter or 9-meter overall system configurations, delivering linear eddy-current measurement to a paired 3300 XL Proximitor sensor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEddy-Current Measurement Principle:\u003c\/strong\u003e Delivers non-contact displacement measurement with high accuracy and repeatability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Probe Geometry:\u003c\/strong\u003e Features a 4.0-inch unthreaded section and a 6.0-inch overall case length, ideal for recessed or deep-well installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnarmored Design:\u003c\/strong\u003e Provides a lightweight, flexible cable profile suited for routing through protective conduit or guide tubes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Miniature Coaxial ClickLoc Connector:\u003c\/strong\u003e Ensures reliable, vibration-resistant electrical connection with standard extension cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChina Hazardous Area Approval (-CN):\u003c\/strong\u003e Explicitly certified under NEPSI and CCC standards for deployment in explosive and hazardous atmospheres within mainland China.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged System Integration:\u003c\/strong\u003e Offers full compatibility with Bently Nevada 3300 XL Proximitor sensors and 3500 rack monitoring channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 330101-40-60-05-02-CN probe is deployed in heavy-duty machinery monitoring systems across industries such as petrochemicals, power generation, and natural gas transmission. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration monitoring on steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position and rotor displacement measurement in high-speed compressors and turbocompressors.\u003c\/li\u003e\n  \u003cli\u003eCasing expansion and differential expansion monitoring.\u003c\/li\u003e\n  \u003cli\u003eShaft orbit, eccentricity, and speed sensing on generator and pump bearings.\u003c\/li\u003e\n  \u003cli\u003eCritical rotating asset protection in hazardous areas requiring CCC and NEPSI compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 3300 XL 8 mm proximity probe part numbers represent a configured assembly. The segment breakdown for this specific SKU is detailed in the table below:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-40-60-05-02-CN\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor, with China hazardous approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e40\u003c\/td\u003e\n      \u003ctd\u003e4.0 inches (102 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60\u003c\/td\u003e\n      \u003ctd\u003e6.0 inches (152 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (1.6 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSuffix -CN\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-CN\u003c\/td\u003e\n      \u003ctd\u003eChina hazardous area approval package (NEPSI, CCC, and relevant markings)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-40-60-05-02-CN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNon-contact displacement (vibration and position)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored standard cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 inches (102 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.0 inches (152 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (1.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation of the 3300 XL 8 mm proximity probe is essential for achieving calibrated measurement performance and maintaining machinery protection:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap Calibration:\u003c\/strong\u003e Mount the probe with the appropriate physical gap between the probe tip and the target shaft surface. Typically, this is set using the DC voltage output of the Proximitor sensor (nominally -10 VDC at the center of the linear range).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement and Locknut:\u003c\/strong\u003e Secure the probe body into the bracket or housing using the recommended thread torque. Ensure the locknut is securely tightened to prevent movement during machine operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Route the unarmored coaxial cable through a dedicated, grounded metal conduit or tray system to protect it from mechanical wear, cutting, and electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e Do not bend the coaxial cable tighter than the minimum recommended bend radius of 25.4 mm (1.0 inch) to prevent internal core damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Handshake:\u003c\/strong\u003e Ensure ClickLoc connectors are fully clean and dry before mating. Use silicone tape or connector protectors if the junction is exposed to oil or moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis configuration carries specific hazard classifications and compliance marks suitable for global and regional operations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChina Certifications (NEPSI \u0026amp; CCC):\u003c\/strong\u003e Certified for safe operation in explosive gas and dust atmospheres in mainland China, meeting CCC (China Compulsory Certification) and NEPSI standards under the -CN approval package.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGeneral Industrial Compliance:\u003c\/strong\u003e Designed in accordance with international machinery protection standard API 670 for eddy-current transducer systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Compliant:\u003c\/strong\u003e Manufactured using materials compliant with standard European and global hazardous substance restrictions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525385067,"sku":"330101-40-60-05-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-40-60-05-02-cn-3300-xl-8-mm-proximity-probes-qapxxte0gnb_21dc0b76-b7a9-48db-a995-90360fdd5181.jpg?v=1765440263"},{"product_id":"bently-nevada-330180-085-03-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-085-03-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 085 (8.5 meters length), Option 03 (armored cable with connector protector), and Option 05 (CSA\/ATEX\/IECEx approvals) specify this 3300 XL \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e configuration — \u003cstrong\u003e330180-085-03-05\u003c\/strong\u003e. This sensor module functions as a signal conditioner, driving the eddy-current proximity probe and translating the high-frequency transducer signal into a proportional displacement voltage. The analog voltage output represents the exact gap change between the probe tip and the observed shaft target area, transmitting directly into machinery protection monitors.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e330180-085-03-05\u003c\/strong\u003e configuration is specifically calibrated for an 8.5 m total electrical system length (Option 085) and supports armored extension cabling assemblies paired with integrated fluorosilicone connector protectors (Option 03). Designed for installation in environments demanding rigorous intrinsic safety and non-sparking certifications, it includes comprehensive international approvals (Option 05) such as ATEX, IECEx, and CSA. The module incorporates electrical isolation in its base, removing the necessity of separate insulator plates and facilitating direct DIN rail or panel mounting.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8.5 Meter Calibrated Length (Option 085):\u003c\/strong\u003e Generates matching impedance parameters calibrated to an 8.5 m proximity probe and cable configuration, preventing impedance mismatch errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling Armor Integration (Option 03):\u003c\/strong\u003e Formulated to seamlessly match armored extension cables with integrated connector protectors to shield delicate connections from fluids and particulates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals (Option 05):\u003c\/strong\u003e Holds CSA, ATEX, and IECEx approvals for safe utilization in hazardous industrial locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRFI\/EMI Noise Immunity:\u003c\/strong\u003e Suppresses electrical noise from surrounding radios and variable frequency drives, complying with European CE requirements without requiring specialized metallic conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpringLoc Terminals:\u003c\/strong\u003e Uses spring-clamp connections that eliminate screws and prevent the connection degradation typically caused by machine vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and dynamic profiling on steam and gas turbines\u003c\/li\u003e\n\u003cli\u003eAxial position and thrust offset measurement on centrifugal compressor shafts\u003c\/li\u003e\n\u003cli\u003eRotor casing expansion and eccentricity monitoring in power generation installations\u003c\/li\u003e\n\u003cli\u003eBearing clearance and structural vibration tracking on high-power industrial motors and pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-085-03-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, armored compatibility\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Calibrated Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e085\u003c\/td\u003e\n      \u003ctd\u003e8.5 meters (27.9 feet) system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Cabling and Protection Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eArmored cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-085-03-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCalibrated Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.5 meters (27.9 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog proportional voltage (typically -10 VDC to -24 VDC range or 7.87 V\/mm [200 mV\/mil])\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRequired Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-24 VDC nominal supply (typically -18 VDC to -26 VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpringLoc terminal strips (accepts up to 1.5 mm2 \/ 16 AWG wire)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePanel mount or 35 mm DIN rail compatible configurations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81 mm x 61 mm x 51 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the industrial terminal block is wired with shielded, twisted-pair cabling to shield the dynamic analog displacement signal from electrical noise.\u003c\/li\u003e\n\u003cli\u003eSecurely clamp the housing onto a standard 35 mm DIN rail or bolt directly to a panel. The integrated base isolation eliminates the need for separate non-conductive isolator plates.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends in any connected probe or extension cabling, maintaining a bend radius above 25.4 mm (1.0 inch) to prevent physical cable damage or signal degradation.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring by inserting a flat-blade screwdriver to release the spring-clamp inside the terminal, sliding in the stripped wire, and releasing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Approved for hazardous zone applications as intrinsically safe (Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc) or non-sparking (Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified for Class I, Division 1, Groups A, B, C, and D hazardous environments when paired with intrinsically safe barriers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with standard European RFI\/EMI directives without requiring high-cost metallic conduit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525417835,"sku":"330180-085-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-085-03-05-proximity-probe-housing-assemblies-vp0dr22uf4n_f1685e23-303f-46ea-b271-e47a4108d19f.jpg?v=1765440264"},{"product_id":"bently-nevada-330101-00-13-15-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-13-15-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-00-13-15-02-05\u003c\/strong\u003e is an unarmored \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e specifically configured with a 3\/8-24 UNF thread, a 0.0-inch unthreaded length, and a compact 1.3-inch overall case length. This particular configuration features a 1.5-meter (4.9-foot) overall length and is terminated with a miniature coaxial ClickLoc connector (without a connector protector), utilizing standard triaxial cable. It comes with CSA, ATEX, and IECEx approvals for installation in hazardous environments, distinguishing it from non-certified configurations (-00) and those with protective armor, metric threads, or alternative length options.\u003c\/p\u003e\n\u003cp\u003eOperating on the eddy current principle, the probe measures non-contact static (position) and dynamic (vibration) values. It delivers high-precision displacement data by measuring the gap between the probe tip and any observed conductive target (such as AISI 4140 steel). It functions as part of a 3300 XL machinery protection loop, interfacing with a 3300 XL Proximitor sensor (such as the 330180 series) and a standard extension cable, which then transmits the analog signal to 3500 rack monitoring systems or other compatible industrial control platforms. The unarmored design makes it ideal for tight bearing housings and machinery casings where routing space is clear and secondary abrasion protection is not required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 mm tip diameter proximity probe designed for high-resolution, non-contact eddy-current displacement measurements.\u003c\/li\u003e\n  \u003cli\u003e3\/8-24 UNF threaded body without armor, suitable for standard mounting installations.\u003c\/li\u003e\n  \u003cli\u003e0.0-inch unthreaded length and 1.3-inch overall case length for low-profile, short-reach sensor mounting.\u003c\/li\u003e\n  \u003cli\u003e1.5-meter (4.9-foot) integrated standard triaxial cable terminated with a gold-plated miniature coaxial ClickLoc connector.\u003c\/li\u003e\n  \u003cli\u003ePatented TipLoc molding method provides a robust bond between the polyphenylene sulfide (PPS) tip and the stainless steel body.\u003c\/li\u003e\n  \u003cli\u003ePatented CableLoc design provides up to 330 N (75 lbf) pull strength between the probe cable and probe body.\u003c\/li\u003e\n  \u003cli\u003eHighly interchangeable with other 3300 XL system components without requiring manual calibration or bench matching.\u003c\/li\u003e\n  \u003cli\u003eFully compatible with 3300 XL Proximitor sensors and standard 3300 XL extension cables.\u003c\/li\u003e\n  \u003cli\u003eAgency certified (Option 05) with CSA, ATEX, and IECEx approvals for hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFluid-film bearing machinery displacement and vibration monitoring.\u003c\/li\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration measurement.\u003c\/li\u003e\n  \u003cli\u003eCompressor and pump rotor axial position and displacement tracking.\u003c\/li\u003e\n  \u003cli\u003eKeyphasor reference, phase angle, and rotational speed measurements.\u003c\/li\u003e\n  \u003cli\u003eHigh-vibration rotating machinery protection loops in oil, gas, power generation, and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-13-15-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e13\u003c\/td\u003e\n      \u003ctd\u003e1.3 in (33 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n      \u003ctd\u003e1.5 meters (4.9 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-13-15-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem \/ Product Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStatic displacement (position) and dynamic displacement (vibration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF (without armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.3 in (33 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 meters (4.9 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard 75 ohm triaxial fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated miniature coaxial ClickLoc connector (without connector protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Probe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.73 ohms +\/- 0.50 ohms (between center conductor and outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Relative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 3% change in Average Scale Factor (ASF) when tested in 93% humidity per IEC 68-2-3 (up to 56 days)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMechanical Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) maximum rated (probe case to probe lead); 270 N (60 lbf) at probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.5 N-m (66 in-lbf) recommended; 11.2 N-m (100 in-lbf) maximum rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the probe is mounted with the correct probe gap (typically 1.27 mm or 50 mils for standard calibration) relative to the target surface.\u003c\/li\u003e\n  \u003cli\u003eRoute the probe cable with proper shielding and grounding practices to prevent electrical noise interference in the proximity chain.\u003c\/li\u003e\n  \u003cli\u003eAdhere to the recommended mounting torque of 7.5 N-m (66 in-lbf) on the 3\/8-24 UNF threads, avoiding the maximum rating of 11.2 N-m (100 in-lbf) to prevent binding.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the minimum cable bend radius of 25.4 mm (1.0 in) during routing to preserve cable electrical properties and prevent core damage.\u003c\/li\u003e\n  \u003cli\u003eKeep the miniature coaxial ClickLoc connector clean and free from oil or moisture prior to connection; tighten only finger-tight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eATEX\/IECEx: Intrinsically Safe (Ex ia IIC T5...T1 Ga) and Non-Sparking\/Increased Safety (Ex nA\/ec IIC T5...T1 Gc) when installed per Bently Nevada drawing 141092 or 140979.\u003c\/li\u003e\n  \u003cli\u003eCSA: Approved for hazardous area installations in North America when installed with appropriate barriers.\u003c\/li\u003e\n  \u003cli\u003eCE: Compliant with European electromagnetic compatibility (EMC) directive requirements without requiring special shielded conduit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525483371,"sku":"330101-00-13-15-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-13-15-02-05-proximity-probes-uqrug5rnkp1_15fbc2bf-28a3-4cba-8319-bc4d651436a1.jpg?v=1765440266"},{"product_id":"bently-nevada-330101-00-12-50-01-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-12-50-01-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eAchieve precise, non-contact shaft vibration and displacement measurements with the \u003cstrong\u003eBently Nevada 330101-00-12-50-01-05\u003c\/strong\u003e, a heavy-duty \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e belonging to the 3300 XL 8 mm Proximity Transducer System family. This specific configuration features a 5.0 meter total length, allowing it to connect directly to a 5 meter Proximitor sensor without requiring an intermediate extension cable, which eliminates a connector connection and reduces potential failure points in demanding industrial environments. Built with a 3\/8-24 UNF threaded casing, it has a fully threaded 1.2-inch overall case length (0.0-inch unthreaded length) and is designed without armor. The cable terminates in a gold-plated miniature coaxial ClickLoc connector fitted with a rugged connector protector to shield the junction from fluid contamination and mechanical wear. Engineered for hazardous locations, this configuration is certified under CSA, ATEX, and IECEx standards.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 mm tip diameter PPS (polyphenylene sulfide) probe tip provides robust structural integrity and resistance to chemical corrosion.\u003c\/li\u003e\n  \u003cli\u003eFully threaded 1.2-inch (30.5 mm) stainless steel body (AISI 303 or 304) with standard 3\/8-24 UNF threads.\u003c\/li\u003e\n  \u003cli\u003e5.0-meter integrated standard triaxial FEP-insulated probe cable connects directly to a 5-meter Proximitor sensor.\u003c\/li\u003e\n  \u003cli\u003eClickLoc coaxial connector equipped with a protective connector sleeve (connector protector) to isolate the junction from oil, water, and mechanical stress.\u003c\/li\u003e\n  \u003cli\u003eRated for hazardous areas with extensive international certifications, including CSA, ATEX, and IECEx.\u003c\/li\u003e\n  \u003cli\u003eEliminates the need for an extension cable, simplifying installation and cable management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFluid-film bearing housing monitoring in gas and steam turbines.\u003c\/li\u003e\n  \u003cli\u003eRadial vibration and axial thrust position measurement in critical centrifugal compressors, pumps, and fans.\u003c\/li\u003e\n  \u003cli\u003eKeyphasor reference, phase angle, and speed measurement on high-speed rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection systems in oil and gas, petrochemical, and power generation industries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"text-align: left;\"\u003eOption Segment\u003c\/th\u003e\n      \u003cth style=\"text-align: left;\"\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth style=\"text-align: left;\"\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12\u003c\/td\u003e\n      \u003ctd\u003e1.2 in (30.5 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) total probe length (designed for use with 5-meter Proximitor sensor only; no extension cable required)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals (for hazardous locations)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"text-align: left;\"\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-12-50-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDisplacement (non-contact proximity \/ vibration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.2 in (30.5 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard 75 Ohm triaxial FEP insulated (non-armored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal DC Resistance (R_PROBE)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.73 ohms plus\/minus 0.50 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum Rated)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"text-align: left;\"\u003eComponent\u003c\/th\u003e\n      \u003cth style=\"text-align: left;\"\u003eInterface Connection Type\u003c\/th\u003e\n      \u003cth style=\"text-align: left;\"\u003eMaterial \u0026amp; Characteristics\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Output Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc plug\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or gold-plated beryllium copper; provides reliable, click-locking connection.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Connector Protector\u003c\/td\u003e\n      \u003ctd\u003eProtective rubber sleeve designed to isolate the coaxial union from oil, dust, and moisture entry.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDirect Connection to Proximitor\u003c\/td\u003e\n      \u003ctd\u003ePlugs directly into the input of a 5-meter 3300 XL Proximitor Sensor (e.g., 330180-50-XX) without an extension cable.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap:\u003c\/strong\u003e Set the nominal probe gap (typically 1.27 mm \/ 50 mils) using a caliper or by monitoring the DC output voltage of the Proximitor sensor during adjustment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Do not exceed standard thread engagement limits. For 3\/8-24 UNF, the maximum length of thread engagement is 0.563 inches (14.3 mm) to avoid binding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Apply a maximum case torque of 11.2 Nm (100 in-lbf) during installation on bearing housings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 in). Route the cable with proper mechanical guarding to prevent abrasion. Always isolate and ground the cable shielding properly to avoid electrical noise interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProximitor Matching:\u003c\/strong\u003e Since this is a 5-meter total length probe, it must only be connected to a matching 5-meter Proximitor sensor. No extension cable is permitted, which ensures overall calibration matches exactly 5.0 meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e CSA, ATEX, IECEx\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClassifications:\u003c\/strong\u003e Ex ia IIC, Ex nA IIC\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCE Compliant\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525581675,"sku":"330101-00-12-50-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-12-50-01-05-3300-xl-8-mm-probes-kfj5xddivm0_779c7c54-e53e-47ee-aba6-d7f2802d99c5.jpg?v=1765440267"},{"product_id":"bently-nevada-330851-02-000-080-10-00-00-3300-xl-25-mm-proximity-probe","title":"Bently Nevada 330851-02-000-080-10-00-00 3300 XL 25 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330851-02-000-080-10-00-00\u003c\/strong\u003e specifies this Bently Nevada 3300 XL 25 mm proximity probe configuration: M30x2 metric threaded case (Option 02), 0.0 mm unthreaded length (Option 000), 80 mm overall case length (Option 080), 1.0 m total cable length (Option 10), without protective armor (Option 00), and without hazardous area agency approvals (Option 00).\u003c\/p\u003e\n\u003cp\u003eThis eddy-current non-contact sensor is used with the 3300 XL 25 mm Proximitor Sensor and extension cable to measure large-target displacement in turbomachinery applications. It has a linear range of 12.7 mm (500 mils) and is typically used for steam turbine differential expansion (DE), thrust position, and rod-drop monitoring. Unlike armored options, this variant features a flexible FluidLoc triaxial cable without external metal armor, simplifying installation routing through tight internal conduits. While standard configurations may request the -05 multiple approvals package for hazardous areas, this specific unit is configured with the -00 no-approval option for non-hazardous locations or standard industrial installations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 02 configuration includes an M30x2 metric threaded body in AISI 304 stainless steel.\u003c\/li\u003e\n\u003cli\u003eOption 000 unthreaded length specifies a fully threaded case length of 80 mm (Option 080).\u003c\/li\u003e\n\u003cli\u003eOption 10 total length includes a 1.0-meter integrated probe cable with ClickLoc coaxial connector.\u003c\/li\u003e\n\u003cli\u003eOption 00 unarmored 75-ohm FluidLoc triaxial probe cable made with perfluoroalkoxyethylene (PFA) insulation.\u003c\/li\u003e\n\u003cli\u003eViton O-ring and rear compression seal prevent moisture ingress.\u003c\/li\u003e\n\u003cli\u003eLarge-target capability provides a linear range of 12.7 mm (500 mils) with a nominal average scale factor of 0.787 V\/mm (20 mV\/mil).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial rotating machinery monitoring\u003c\/li\u003e\n\u003cli\u003eSteam turbine differential expansion (DE) measurements\u003c\/li\u003e\n\u003cli\u003eThrust position and axial displacement monitoring\u003c\/li\u003e\n\u003cli\u003eReciprocating compressor rod-drop monitoring\u003c\/li\u003e\n\u003cli\u003eLarge shaft target radial or axial displacement sensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330851-02-000-080-10-00-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Proximity Probe, Metric Threaded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Probe Case Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eM30x2 thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e000\u003c\/td\u003e\n\u003ctd\u003e0.0 mm (fully threaded case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 metre (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Armor Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eF - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330851-02-000-080-10-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.7 mm (500 mils), beginning at approximately 0.63 mm (25 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.31 mm (+\/-12 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 2.7 kHz (+0, -3 dB typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Minimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 mm (2.4 in) diameter flat target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyetheretherketone (PEEK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial PFA-insulated FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-temperature ClickLoc coaxial connectors with removable collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe dc Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.2 +\/- 0.5 ohms (Center Conductor to Outer Conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Operating \u0026amp; Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +200 degC (-31 degF to +392 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Term Temperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+250 degC (482 degF) max for less than 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Sealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton O-ring and compression seal designed to seal differential pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProbe gap should be calibrated at approximately 7.0 mm (275 mils) or -6.5 Vdc to set the center of the linear range.\u003c\/li\u003e\n\u003cli\u003eEnsure the target size meets the minimum 61 mm (2.4 in) diameter requirement for standard calibration.\u003c\/li\u003e\n\u003cli\u003eUse the included connector protectors and disposable installation tools to prevent moisture or particulate contamination on ClickLoc connectors.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum cable bend radius of 25.4 mm (1.0 in) for unarmored FluidLoc cables.\u003c\/li\u003e\n\u003cli\u003eThreaded probe cases should be secured using the supplied locknut with safety wire holes. Torque the M30x2 threads properly to avoid damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Mark (European Union compliance)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525811051,"sku":"330851-02-000-080-10-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330851-02-000-080-10-00-00-proximity-probe-lmlsi5o2pkh_96682829-6b7d-4e24-b7f1-b4208e37e653.jpg?v=1765440271"},{"product_id":"bently-nevada-330730-040-02-00-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-040-02-00 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 040 (4.0 m cable length) and Option 02 (standard cable with connector protector) specify this 3300 XL 11 mm extension cable configuration — \u003cstrong\u003e330730-040-02-00\u003c\/strong\u003e. This unarmored coaxial cable links a 3300 XL 11 mm proximity probe with a 3300 XL 11 mm Proximitor sensor, completing a 5.0-meter or 9.0-meter transducer system. The standard FEP insulation offers excellent chemical resistance and temperature tolerance in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eUnlike armored variants or those featuring FluidLoc technology, this configuration focuses on flexibility and clean routing while adding a pre-installed fluorosilicone connector protector. The connector protector shields the ClickLoc junction against moisture and contaminants, which is ideal for humid or wet environments. Since Option 00 is selected for agency approvals, this specific variant does not require hazardous area compliance certificates.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 040 provides a 4.0-meter (13.1 feet) physical cable length.\u003c\/li\u003e\n  \u003cli\u003eOption 02 equips the cable with a pre-installed fluorosilicone connector protector on the female end.\u003c\/li\u003e\n  \u003cli\u003eOption 00 designates that no specific hazardous area agency approvals are required for this configuration.\u003c\/li\u003e\n  \u003cli\u003e75 Ohm triaxial construction with fluoroethylene propylene (FEP) insulation.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc coaxial connectors lock securely to prevent loosening from vibration.\u003c\/li\u003e\n  \u003cli\u003eUnarmored cable design maintains a minimum bend radius of 25.4 mm (1.0 in) for tight routing paths.\u003c\/li\u003e\n  \u003cli\u003eRated tensile strength of 270 N (60 pounds) at the probe lead to extension cable connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is used within Bently Nevada 3300 XL 11 mm proximity transducer systems for vibration and position monitoring of large rotating machinery. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial thrust position monitoring.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal and axial compressor vibration analysis.\u003c\/li\u003e\n  \u003cli\u003eCritical rotating machinery protection where 11 mm probe systems are required.\u003c\/li\u003e\n  \u003cli\u003eHumid or moist industrial environments where the connector protector prevents ingress of moisture into the coaxial junction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330730-040-02-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Extension Cable, standard unarmored coaxial cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required \/ No approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330730-040-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial, FEP-insulated coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClickLoc miniature coaxial connectors (gold-plated brass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePre-installed fluorosilicone connector protector on female end\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance (Core)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.3 +\/- 0.1 Ohm (center conductor to center conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance (Jacket)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 +\/- 0.25 Ohm (coaxial conductor to coaxial conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 lb) maximum at probe-to-cable connector interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHumidity Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTested to IEC 68-2-3 damp heat\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePairs with 3300 XL 11 mm probes and 330780 Proximitor Sensors\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the 3300 XL 11 mm extension cable, follow these engineering best practices to ensure optimal signal transmission and mechanical longevity:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 in) along the entire cable length to prevent internal conductor damage or impedance changes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection Integrity:\u003c\/strong\u003e Hand-tighten ClickLoc coaxial connectors. Do not use pliers or other tools that could over-torque and damage the gold-plated contacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Ensure the pre-installed fluorosilicone connector protector is fully seated and clicked over the junction to block moisture, dirt, and industrial oils.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRouting and Conduit:\u003c\/strong\u003e Route the cable through dedicated, grounded metal conduit to isolate the low-voltage signal from high-voltage electromagnetic interference (EMI) sources.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the system shield is properly grounded at the monitor\/instrumentation end only. Do not ground the cable shield at multiple points, as this can introduce ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330730-040-02-00 configuration is ordered with the Option 00 agency approval selection. As such, this specific extension cable is designed for use in non-hazardous, general-purpose industrial environments and does not carry individual explosion-proof or intrinsic safety certificates.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with European Community Directive 2011\/65\/EU (RoHS).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility (EMC):\u003c\/strong\u003e Complies with European Community Directive 2014\/30\/EU when used as part of a fully compatible and shielded Bently Nevada 3300 XL transducer system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525876587,"sku":"330730-040-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330730-040-02-00-extension-cable-cdoz0ldi1n2_0131774c-680c-4d2e-91b7-90f0083747a4.jpg?v=1765440272"},{"product_id":"bently-nevada-330190-085-00-05-3300-xl-extended-temperature-range-extension-cable","title":"Bently Nevada 330190-085-00-05 3300 XL Extended Temperature Range Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330190-085-00-05\u003c\/strong\u003e: 3300 XL Extended Temperature Range (ETR) extension cable, specifying an 8.5-meter length (Option 085) with standard unarmored construction (Option 00) and CSA, ATEX, and IECEx hazardous area approvals (Option 05). This component is designed for demanding proximity transducer installations where temperatures exceed the thresholds of standard cabling systems. The extension cable operates as a medium between the proximity probe and the Proximitor Sensor, conveying high-frequency eddy-current signals to measure shaft vibration, axial position, and speed on critical rotating machinery.\u003c\/p\u003e\n\n\u003cp\u003eIn contrast to armored ETR options such as Option 01, this variant (Option 00) features a standard unarmored PFA-insulated cable with a maximum outside diameter of 3.7 mm. Standard temperature extension cables (model 330130) are rated up to 177 Celsius (350 Fahrenheit), whereas this 330190 ETR cable provides an extended temperature rating of up to 260 Celsius (500 Fahrenheit). It uses gold-plated ClickLoc coaxial connectors on both ends to construct a secure and low-resistance signal path that remains stable under high vibrational stresses, matching the calibration performance of standard 3300 XL Proximitor Sensors without requiring manual recalibration.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 085 specifies an 8.5-meter (27.9 feet) overall cable length, designed to combine with compatible probes to complete a 9.0-meter proximity transducer system.\u003c\/li\u003e\n  \u003cli\u003eOption 00 provides a standard unarmored cable design featuring PFA insulation and a maximum outside diameter of 3.7 mm.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides CSA, ATEX, and IECEx certifications for use in hazardous areas.\u003c\/li\u003e\n  \u003cli\u003ePFA insulation material supports a continuous operating and storage temperature range of -51 Celsius to +260 Celsius (-60 Fahrenheit to +500 Fahrenheit).\u003c\/li\u003e\n  \u003cli\u003eGold-plated ClickLoc coaxial connectors require only finger-tight torque and feature an integrated locking mechanism to prevent loosening from vibration.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in CableLoc design provides a secure mechanical connection with high pull strength between the cable and connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and position monitoring in steam turbines, gas turbines, and generators.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection systems in hydrocarbon processing plants and petrochemical facilities.\u003c\/li\u003e\n  \u003cli\u003eHigh-temperature rotating machinery monitoring where ambient temperatures exceed 177 Celsius.\u003c\/li\u003e\n  \u003cli\u003eTurbo-compressor and gearbox diagnostic monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330190-085-00-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Extended Temperature Range (ETR) Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e085\u003c\/td\u003e\n      \u003ctd\u003e8.5 meters (27.9 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eStandard cable (unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330190-085-00-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtended Temperature Range (ETR) Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.5 meters (27.9 feet) (Option 085)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Armor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard unarmored cable (Option 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePFA (Perfluoroalkoxy) insulation and jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 Celsius to +260 Celsius (-60 Fahrenheit to +500 Fahrenheit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature male and female coaxial ClickLoc connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.7 mm (0.15 in) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) maximum pull strength (CableLoc design)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx (Option 05)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.29 kg (289 g)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e300 mm x 300 mm x 20 mm (H x W x D) (coiled)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFinger-tighten the gold \"click\" type connectors until they click to lock in place. No special tools are required.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the minimum cable bend radius of 25.4 mm (1.0 in) during installation to prevent damage to the internal coaxial conductors.\u003c\/li\u003e\n  \u003cli\u003eIf running through conduit, standard practice is to use connector protectors to safeguard against entry of dust and moisture.\u003c\/li\u003e\n  \u003cli\u003eEnsure the sum of the extension cable length and the probe length matches the calibrated length of the Proximitor Sensor (e.g., 9.0-meter total system length).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA: Intrinsically Safe and Non-Incendive approvals for hazardous locations.\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: Ex ia IIC T5...T1 Ga for intrinsically safe installations in Zone 0\/1\/2.\u003c\/li\u003e\n  \u003cli\u003eCE: Compliant with relevant European directives.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525909355,"sku":"330190-085-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330190-085-00-05-extension-cable-zep4dztnnhj_950e338e-0583-4a68-b80d-31b27002f02a.jpg?v=1765440273"},{"product_id":"bently-nevada-330101-00-45-15-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-45-15-02-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-00-45-15-02-00\u003c\/strong\u003e is an unarmored, standard-threaded \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e designed for high-precision, non-contact machinery vibration and shaft position measurements. As a core component of the Bently Nevada 3300 XL monitoring system, this eddy-current sensor provides outstanding performance and stability in harsh industrial machinery environments. Unlike other configurations in its family that may feature protective armor or metric threads, this specific variant features a standard 3\/8-24 UNF thread, a fully threaded 4.5-inch case with 0.0 inches of unthreaded length, and a standard 1.5-meter (4.9 feet) coaxial cable terminated with a miniature coaxial ClickLoc connector.\u003c\/p\u003e\n\u003cp\u003eThis proximity probe is ideal for permanent installation on bearing housings and machine casings to monitor steam turbines, gas turbines, compressors, and pumps. It connects seamlessly to a Bently Nevada 330180 series Proximitor sensor via an extension cable to complete the 3300 XL transducer chain, which interfaces directly with 3500 series rack monitoring systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 mm tip diameter optimized for non-contact eddy-current displacement and vibration measurements\u003c\/li\u003e\n  \u003cli\u003eFully threaded 4.5-inch case body without unthreaded sections for rigid and deep mounting setups\u003c\/li\u003e\n  \u003cli\u003e1.5-meter standard coaxial cable without protective armor, perfect for installations inside protective conduits\u003c\/li\u003e\n  \u003cli\u003eEquipped with a miniature coaxial ClickLoc connector to ensure reliable signal transmission\u003c\/li\u003e\n  \u003cli\u003eRobust Viton O-ring tip-to-case pressure seal preventing leakage of lubrication oils and fluids\u003c\/li\u003e\n  \u003cli\u003eHigh-stability performance over a wide temperature range for dependable machinery protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis 8 mm proximity probe is widely utilized across heavy industrial sectors including power generation, oil and gas, petrochemical processing, and mining. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position measurements on high-speed steam and gas turbine shafts\u003c\/li\u003e\n  \u003cli\u003eRotor displacement monitoring in critical industrial compressors, generators, and pumps\u003c\/li\u003e\n  \u003cli\u003ePermanent mechanical protection and predictive maintenance of rotating machinery bearings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eOption Segment\u003c\/th\u003e\n    \u003cth\u003eCode Value\u003c\/th\u003e\n    \u003cth\u003eMeaning \/ Configuration\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eBase Model \/ Product Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e330101\u003c\/td\u003e\n    \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e00\u003c\/td\u003e\n    \u003ctd\u003e0.0 in unthreaded length\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e45\u003c\/td\u003e\n    \u003ctd\u003e4.5 in overall case length\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e15\u003c\/td\u003e\n    \u003ctd\u003e1.5 meter (4.9 feet) total length\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eD - Connector \u0026amp; Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e02\u003c\/td\u003e\n    \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e00\u003c\/td\u003e\n    \u003ctd\u003eAgency approvals not required\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e330101-00-45-15-02-00\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eDisplacement (proximity)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eEddy current\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e8 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e4.5 in (114.3 mm)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e1.5 m (4.9 ft)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eStandard coaxial cable, without armor\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eNominal DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e7.73 +\/- 0.50 ohms (center conductor to outer conductor)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003ePressure Sealing\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eViton O-ring differential pressure seal\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0.14 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the proximity probe in accordance with standard Bently Nevada procedures. Position the probe tip at the specified gap voltage (typically set per 3300 XL Proximitor requirements at 1.27 mm or 50 mils) to achieve linear displacement scaling. Securely thread the probe casing into the bearing block or bracket. Route the 1.5-meter coaxial cable through protective electrical conduits, avoiding sharp bends, and use proper shielding and grounding practices to ensure maximum immunity against electromagnetic interference (EMI).\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis specific configuration (Agency Approval Option -00) does not require hazardous area approvals. For installations demanding ATEX, IECEx, or CSA certifications, please select sibling configurations with the -05 approval option.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526040427,"sku":"330101-00-45-15-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-45-15-02-00-3300-xl-8-mm-probe-msa03h4uxh4_40698efc-f61b-4823-88c4-dd3b5d68b52f.jpg?v=1765440276"},{"product_id":"bently-nevada-330704-000-060-90-02-00-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330704-000-060-90-02-00 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 000 (0 mm unthreaded length), Option 060 (60 mm overall case length), and Option 90 (9.0 meters total length) specify this metric-thread, armored configuration of the \u003cstrong\u003eBently Nevada 330704-000-060-90-02-00\u003c\/strong\u003e, a non-contact eddy-current \u003cstrong\u003e3300 XL 11 mm Proximity Probe\u003c\/strong\u003e. This industrial transducer component works as part of a 3300 XL 11 mm proximity system, generating a linear output voltage proportional to the distance between the probe tip and a target surface, such as a rotating shaft. The M14 x 1.5 metric thread and standard flexible armor make it suitable for installation in machinery housings where physical impacts, moisture, or fluid contaminants are present.\u003c\/p\u003e\n\n\u003cp\u003eThis specific variant features a flexible AISI 302 stainless steel armor sleeve with an outer FEP jacket, protecting the underlying 75-ohm triaxial cable from physical abrasion and wear. Unlike configurations containing integrated connector protectors (Option 01), this unit is optioned with a standard miniature coaxial ClickLoc connector (Option 02), allowing standard connections without additional boots. It is also supplied with the Option 00 agency approval, designated for general-purpose, non-hazardous monitoring applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM14 x 1.5 metric threaded probe case (Model 330704) with built-in flexible stainless steel armor.\u003c\/li\u003e\n  \u003cli\u003e0 mm unthreaded length (Option 000) allowing the full 60 mm case length (Option 060) to be utilized for depth positioning.\u003c\/li\u003e\n  \u003cli\u003e9.0 meters total probe length (Option 90) eliminating the need for an intermediate extension cable in standard installations.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector (Option 02) providing a low-profile, secure coaxial connection.\u003c\/li\u003e\n  \u003cli\u003eOption 00 approval designation, ideal for general-purpose applications where hazardous area certifications are not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used in industrial machinery protection systems to monitor axial position, radial vibration, and shaft displacement. It is commonly installed on critical rotating machinery, including steam turbines (for differential expansion measurements) and reciprocating compressors (for rod drop and rod position tracking) where physical mechanical protection from armor shielding is necessary.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330704-000-060-90-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Probe, M14 x 1.5 thread, with armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e000\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e60 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required (general-purpose)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330704-000-060-90-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM14 x 1.5 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 stainless steel armor with FEP outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector (gold-plated brass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), starting at 0.5 mm (20 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Accuracy (DSL Deviation)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.10 mm (+\/-4 mils) under standard calibration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz (+0, -3 dB typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Insulation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e63.3 N-m (560 in-lb) maximum; 21.1 N-m (187 in-lb) recommended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Rated Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the metric-threaded probe, do not exceed the recommended installation torque of 21.1 N-m (187 in-lb) for M14 x 1.5 cases, as exceeding 63.3 N-m (560 in-lb) can damage the probe body. Ensure there is a minimum clearance of 30.5 mm around the probe tip to prevent cross-talk or target-size interference from adjacent metallic surfaces. Connectors should be kept clean, dry, and secure. Minimum bend radius for the armored probe cable is 25.4 mm (1.0 inch). Proper grounding and shielding of the transducer system must be maintained back to the monitor to avoid electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis general-purpose configuration (Option 00) is designed for non-hazardous areas and carries the following standard compliance markings:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark (EMC Directive 2014\/30\/EU, RoHS Directive 2011\/65\/EU)\u003c\/li\u003e\n  \u003cli\u003eChina RoHS Compliance\u003c\/li\u003e\n  \u003cli\u003eFCC Part 15 compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526073195,"sku":"330704-000-060-90-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330704-000-060-90-02-00-proximity-probes-mr42jzbxceg_b5ea6e66-c8e3-46b7-9cf0-7860eb85d42e.jpg?v=1765440278"},{"product_id":"bently-nevada-330909-00-80-10-01-05-3300-xl-nsv-proximity-probe","title":"Bently Nevada 330909-00-80-10-01-05 3300 XL NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330909-00-80-10-01-05\u003c\/strong\u003e is an eddy-current \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e developed by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e for non-contacting machinery displacement and shaft vibration monitoring loops. This fractional-thread transducer operates as an integrated sensor input within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e, which is specifically deployed in centrifugal air compressors, refrigeration compressors, and process gas compressors characterized by highly confined internal measurement footprints. By projecting a high-frequency radio frequency (RF) carrier field into the adjacent target area, the sensor continuously captures micro-gap transitions caused by surface-level eddy currents and relays this raw analog displacement wave back to a remote Proximitor module.\u003c\/p\u003e\n\u003cp\u003eThis specialized sensor is engineered for application zones where deep counterbores, severe sideview visibility constraints, or limited rear clearance prohibit the use of standard 5 mm or 8 mm proximity probe designs. The \u003cstrong\u003e330909-00-80-10-01-05\u003c\/strong\u003e configuration features a 3\/8-24 UNF fractional threaded steel casing integrated with an interlocking stainless steel armor sleeve to prevent physical pinching, shearing, and oil-induced outer insulation decay. It is calibrated to measure dynamic radial vibration on narrow shafts smaller than 51 mm (2 in) or axial thrust position on flat target surfaces smaller than 15 mm (0.6 in). Equipped with Multiple Agency Approvals under the corresponding configuration suffix, the probe provides continuous machinery asset protection when marshalled inside classified hazardous plant zones.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-profile transducer tip architecture engineered for tight machinery counterbores and restricted sideview clearance paths.\u003c\/li\u003e\n\u003cli\u003eRugged 3\/8-24 UNF fractional fully-threaded casing matched with an interlocking stainless steel armor wrap for severe mechanical wear protection.\u003c\/li\u003e\n\u003cli\u003eIntegrated gold-plated brass ClickLoc miniature coaxial plug delivering a low-loss, vibration-proof positive locking wire link.\u003c\/li\u003e\n\u003cli\u003eHigh-stability sensor coil optimized to track small target areas, including micro-diameter rotating shafts under 51 mm.\u003c\/li\u003e\n\u003cli\u003eFull drop-in backward compatibility with legacy Bently Nevada 3300 RAM transducer systems and 190 series processing architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial shaft vibration and dynamic fluid-film bearing displacement tracking on industrial high-speed centrifugal compressors.\u003c\/li\u003e\n\u003cli\u003eDual-direction rotor axial thrust position offset capture inside compact turbo-expander gearboxes.\u003c\/li\u003e\n\u003cli\u003eRotating target speed detection, zero-speed confirmation, and Keyphasor phase reference signal generation in tight spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Profile \u0026amp; Exact Weight Formulas\u003c\/h3\u003e\n\u003cp\u003eIn high-integrity asset tracking, using non-specific box dimensions can cause mechanical fouling during bracket adjustment. Per official Bently Nevada 147385 datasheet technical constants, the physical geometry and cumulative dry mass metrics for this specific 1.0-meter fully threaded probe are precisely calculated below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded Case Length (Option A):\u003c\/strong\u003e Exactly \u003cstrong\u003e0.0 inches (0 mm)\u003c\/strong\u003e indicating a fully threaded barrel profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Case Length (Option B):\u003c\/strong\u003e Exactly \u003cstrong\u003e8.0 inches (203.2 mm)\u003c\/strong\u003e representing an extended-reach structural case length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreaded Case Section:\u003c\/strong\u003e Calculated as Overall Case Length minus Unthreaded Length (8.0 in - 0.0 in) = \u003cstrong\u003e8.0 inches (203.2 mm)\u003c\/strong\u003e of active 3\/8-24 UNF threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Physical Cable Length (Option C):\u003c\/strong\u003e Exactly \u003cstrong\u003e1.0 meter (3.9 feet \/ 39 inches)\u003c\/strong\u003e measured from the probe tip face to the terminal coax joint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Mass Density of Armored Cable:\u003c\/strong\u003e Nominal \u003cstrong\u003e64 grams per meter (0.70 oz\/foot)\u003c\/strong\u003e driven by the heavy interlocking stainless steel armor skin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Probe Head and Long-Case Mass:\u003c\/strong\u003e Approximately \u003cstrong\u003e85 grams (3.00 oz)\u003c\/strong\u003e including the extended 8-inch AISI 304 stainless steel threaded shell, sensing coil, and transition hub assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Net Hardware Weight:\u003c\/strong\u003e Calculated as (64 g\/m x 1.0 m) + 85 g = \u003cstrong\u003e149 grams (5.26 oz)\u003c\/strong\u003e absolute net hardware weight per unit (excluding shipping boxes and the accompanying 9\/16-inch industrial lock nut).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330909\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Probe, 3\/8-24 UNF thread, with armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003e0.0 in unthreaded section length (Fully threaded barrel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-80\u003c\/td\u003e\n\u003ctd\u003e8.0 in (203.2 mm) overall case length profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 in) physical cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Connector\/Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (ATEX, IECEx, CSA, FM for hazardous zones)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrecise Engineering Data\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330909-00-80-10-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contacting Eddy-Current Proximity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Mechanical Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF fractional configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils) nominal tracking window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Scale Factor Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) when integrated with NSv Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Nominal Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Case Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in) absolute field bending constraint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLock Nut Size Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\/16-inch hex-face width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWrench Flat Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16-inch integrated flats on probe case body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThreaded 3\/8-24 UNF Barrel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect physical adjustment interface into bracket mount or machine outer wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClickLoc Miniature Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale coaxial terminal linking into the 3300 NSv extension cable path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal System Loop Matching:\u003c\/strong\u003e This 1.0-meter physical length probe \u003cstrong\u003emust\u003c\/strong\u003e be paired with a 4.0-meter extension cable to form a 5.0-meter total system loop, or a 6.0-meter extension cable to form a 7.0-meter total system loop. The total length must precisely match the electrical calibration length of the 3300 XL NSv Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Gap Adjustment:\u003c\/strong\u003e Manually thread the probe into the machine casing until the tip contacts the target surface, then back it out to the designated linear gap voltage threshold (typically -9.0 Vdc or central linear range) before tightening the 9\/16-inch lock nut.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid Ground Contacts:\u003c\/strong\u003e Ensure the miniature coaxial ClickLoc connector junction does not touch the metal walls of the junction box or conduit fittings. Wrap the connected union with self-fusing silicone tape to prevent electrical noise loop interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Protection Routing:\u003c\/strong\u003e The flexible stainless steel armor provides mechanical deflection protection; however, the probe lead wire should still be routed within dedicated low-voltage instrument trays to minimize exposure to high-voltage electromagnetic fields (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526171499,"sku":"330909-00-80-10-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330909-00-80-10-01-05-3300-nsv-proximity-probes-xm5pxmv1kah_010d5d42-1219-4ccf-8350-af7f9f1388e7.jpg?v=1765440280"},{"product_id":"bently-nevada-330102-08-96-10-02-00-3300-xl-8-mm-proximity-probe-with-armor","title":"Bently Nevada 330102-08-96-10-02-00 3300 XL 8 mm Proximity Probe with Armor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 08 (0.8 in unthreaded length) and Option 96 (9.6 in case length) specify this 3300 XL 8 mm probe configuration — \u003cstrong\u003e330102-08-96-10-02-00\u003c\/strong\u003e. This \u003cstrong\u003e3300 XL 8 mm proximity probe\u003c\/strong\u003e features integrated stainless steel armor, a 3\/8-24 UNF thread, a 1.0 m total length, and a ClickLoc miniature coaxial connector without a connector protector. It operates as part of an eddy-current transducer system to measure shaft vibration and axial position on rotating machinery.\u003c\/p\u003e\n\n\u003cp\u003eThis specific variant is configured with a 9.6 in case length and 0.8 in unthreaded length, making it suitable for deep-well probe installations or situations requiring a longer physical reach through machine casing walls. The integral armor provides robust mechanical shielding against physical impacts and abrasion in harsh environments. This configuration requires no hazardous area agency approvals (Option 00) and uses standard cable construction instead of fluid-resistant options.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3\/8-24 UNF threaded steel probe body with integrated protective stainless steel armor.\u003c\/li\u003e\n  \u003cli\u003e0.8 in unthreaded length paired with a 9.6 in overall case length.\u003c\/li\u003e\n  \u003cli\u003e1.0 m (3.3 ft) total cable length with standard cable construction.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector (Option 02, no connector protector).\u003c\/li\u003e\n  \u003cli\u003eHigh resistance to environmental factors, maintaining performance across a wide operating temperature range of -52 degC to +177 degC.\u003c\/li\u003e\n  \u003cli\u003ePressure sealed up to the probe tip using a Viton O-ring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and position monitoring in industrial rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eDeep-reach casing installations on steam turbines, gas turbines, or heavy-duty centrifugal compressors.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection systems where armored cables are required to prevent abrasion or cutting during installation and operation.\u003c\/li\u003e\n  \u003cli\u003eNon-hazardous or general-purpose areas requiring standard industrial-grade proximity sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330102-08-96-10-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, with armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e08\u003c\/td\u003e\n      \u003ctd\u003e0.8 in (20 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e96\u003c\/td\u003e\n      \u003ctd\u003e9.6 in (244 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330102-08-96-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 mm (0.31 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.6 in (243.8 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDifferential pressure sealed between probe tip and case using Viton O-ring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 ohms +\/- 0.50 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e200 mm x 200 mm x 40 mm (H x W x D) (packaged format)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.32 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the probe gap is set correctly (typically 1.27 mm or 50 mils for standard calibration) prior to final tightening. The 3\/8-24 UNF thread has a maximum recommended thread engagement limit of 0.563 in (14.3 mm) to prevent binding. Route the armored cable to avoid sharp bends, keeping the bend radius within the recommended physical tolerances. Connection of the miniature ClickLoc coaxial connector must be made finger-tight.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis specific configuration (Option 00) is intended for general-purpose, non-hazardous area applications and does not carry intrinsic safety or non-incendive hazardous area certifications.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526237035,"sku":"330102-08-96-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330102-08-96-10-02-00-3300-xl-11-mm-probe-dfzm2rgo0cs_b2050e70-2072-4230-a371-ec96dfa596a5.jpg?v=1765440281"},{"product_id":"bently-nevada-330103-00-14-10-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-00-14-10-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330103-00-14-10-02-05\u003c\/strong\u003e specifies this 3300 XL 8 mm proximity probe configuration featuring an M10 x 1 metric thread, 0 mm unthreaded length, 140 mm overall case length, and a 1.0 meter total length. This specific configuration uses a standard miniature coaxial ClickLoc connector (Option 02) without a connector protector and is certified under Option 05 for CSA, ATEX, and IECEx hazardous area operations. As an unarmored metric probe, it mounts directly into threaded ports on rotating machinery to measure shaft vibration, axial position, and oil film thickness.\u003c\/p\u003e\n\u003cp\u003eOperating as a non-contact eddy-current transducer, the probe pairs with a 3300 XL Proximitor sensor and a matching extension cable to form a complete transducer system. The total length of 1.0 meter is specifically configured to combine with a 4.0 meter or 8.0 meter extension cable, establishing a calibrated 5.0 meter or 9.0 meter overall system length. By monitoring physical gap variations between the 8.0 mm probe tip and the target shaft, the system outputs an analog voltage directly proportional to the physical displacement.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eM10 x 1 metric threads with a fully threaded 140 mm case length (Option 14) and 0 mm unthreaded section (Option 00) for deep-reach machinery ports.\u003c\/li\u003e\n\u003cli\u003eUnarmored 75 ohm coaxial cable configuration (Option 02) equipped with a miniature coaxial ClickLoc male connector.\u003c\/li\u003e\n\u003cli\u003eCalibrated 1.0 meter (3.3 feet) overall probe length (Option 10) intended for integration into 5.0 meter or 9.0 meter system configurations.\u003c\/li\u003e\n\u003cli\u003eHazardous area certification (Option 05) covering ATEX, IECEx, and CSA standards for zone-rated industrial environments.\u003c\/li\u003e\n\u003cli\u003eInterchangeable design allowing direct field replacement without recalibration when paired with standard 3300 XL components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical applications include radial vibration and axial thrust position monitoring on high-speed rotating equipment in petrochemical, power generation, and natural gas industries. It is commonly installed in steam turbines, gas turbines, centrifugal compressors, gearboxes, and large industrial pumps to monitor shaft movement and prevent catastrophic machinery damage.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Configuration\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length (fully threaded body)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e14\u003c\/td\u003e\n      \u003ctd\u003e140 mm overall case length (ordered in 10 mm increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector\/Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-00-14-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMetric M10 x 1 (fully threaded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e140 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, standard, unarmored\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc male connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) when paired with 3300 XL Proximitor sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at 0.25 mm (10 mils) from the probe tip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExcitation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc (supplied by Proximitor sensor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Thread Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15 N-m (11 ft-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.15 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e17 mm x 17 mm x 140 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish successful installation, maintain a minimum spacing of at least 40 mm between adjacent proximity probe tips to prevent electromagnetic cross-talk. When threading the M10 x 1 probe body into the machine casing, do not exceed the maximum tightening torque of 15 N-m. Hand-tighten the ClickLoc coaxial connection first, then slide the connector sleeve to lock. Ensure that the coaxial cable bend radius is at least 25 mm to prevent mechanical fatigue or conductor breakages under machine casing vibration.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e II 1 G Ex ia IIC T4\/T5 Ga\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e Ex ia IIC T4\/T5 Ga\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Compliant with European electromagnetic compatibility (EMC) directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with restriction of hazardous substances\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526302571,"sku":"330103-00-14-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-00-14-10-02-05-proximity-probe-vbvaqlt3jrm_feb68180-7ea6-4af6-993a-ca748156419b.jpg?v=1765440282"},{"product_id":"bently-nevada-330701-00-25-10-11-05-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330701-00-25-10-11-05 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0.0 in unthreaded length), Option 25 (2.5 in overall case length), Option 10 (1.0 m total length), Option 11 (ClickLoc connector with protector, FluidLoc cable), and Option 05 (Multiple approvals) specify the exact configuration of this \u003cstrong\u003e330701-00-25-10-11-05\u003c\/strong\u003e \u003cstrong\u003e3300 XL 11 mm Proximity Probe\u003c\/strong\u003e. This non-contacting eddy-current sensor operates within a 3300 XL 11 mm Proximity Transducer System to provide dynamic displacement and static position measurements on rotating machinery. The unarmored 1\/2-20 UNF threaded case configuration allows direct installation in tapped machine housings where external mechanical armor is unnecessary, while the integrated FluidLoc cable prevents moisture and process oil from migrating through the internal probe cable.\u003c\/p\u003e\n\u003cp\u003eUnlike configuration variants that feature standard coaxial cables (Option 01 or 02) or lack mechanical protection at the connection point, this probe utilizes Option 11 to provide both a FluidLoc barrier and a factory-installed connector protector, protecting the ClickLoc coaxial connection from contamination. Additionally, with Option 05, this probe is certified for multiple hazardous area environments (including ATEX, IECEx, and CSA), whereas standard Option 00 probes have no agency approvals. It features an 11 mm tip diameter that provides an extended 4.0 mm (160 mils) linear range, which is significantly longer than standard 8 mm systems, making it suitable for large axial thrust measurements, ramp differential expansion, and reciprocating compressor rod drop monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 00 Unthreaded Case:\u003c\/strong\u003e Features a 0.0-inch unthreaded length, making the 2.5-inch case (Option 25) fully threaded with 1\/2-20 UNF threads for flexible mounting depth.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 11 FluidLoc Cable:\u003c\/strong\u003e Incorporates an FEP-insulated FluidLoc triaxial cable that prevents oil and moisture leakage through the interior of the probe cable, combined with a pre-installed coaxial connector protector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 10 Total Length:\u003c\/strong\u003e Designed as a 1.0-meter (3.3 feet) integral probe system, typically paired with a 4.0-meter extension cable to complete a 5.0-meter system length.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 05 Multiple Approvals:\u003c\/strong\u003e Fully certified under ATEX, IECEx, and CSA standards for safe operation in Class I Division 1\/2 and Zone 0\/2 hazardous locations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e11 mm Tip Diameter:\u003c\/strong\u003e Provides an extended linear range of 4.0 mm (160 mils) and a nominal scale factor of 3.94 V\/mm (100 mV\/mil).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAxial thrust position measurements on steam and gas turbines\u003c\/li\u003e\n  \u003cli\u003eRamp differential expansion measurements on industrial turbomachinery\u003c\/li\u003e\n  \u003cli\u003eRod drop and rod position monitoring on reciprocating compressors\u003c\/li\u003e\n  \u003cli\u003eShaft vibration monitoring on large fluid-film bearing machines\u003c\/li\u003e\n  \u003cli\u003eTachometer, zero speed, and Keyphasor phase reference signal generation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Configuration Detail\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330701-00-25-10-11-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Probe, 1\/2-20 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e25\u003c\/td\u003e\n      \u003ctd\u003e2.5 in (64 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector \u0026amp; Cable Option\u003c\/td\u003e\n      \u003ctd\u003e11\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx, etc.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330701-00-25-10-11-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), from approximately 0.5 to 4.5 mm (20 to 180 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.10 mm (+\/-4 mils) at standard temperatures; less than +\/-0.15 mm (+\/-6 mils) over extended temperatures\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel target, 30.5 mm (1.2 in) diameter or larger\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, FEP-insulated FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with pre-installed connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum Rated)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to probe lead; 270 N (60 lb) probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Probe Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45.2 N-m (400 in-lb) rated; 15.2 N-m (133 in-lb) recommended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.9 +\/-0.5 ohms (between center conductor and outer conductor for 1.0 m length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHand-tighten the probe case into the tapped hole and then tighten to the recommended installation torque of 15.2 N-m (133 in-lb). Do not exceed the maximum rated case torque of 45.2 N-m (400 in-lb).\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum cable bend radius of 25.4 mm (1.0 in) when routing the integral FluidLoc triaxial cable to avoid signal attenuation or conductor damage.\u003c\/li\u003e\n  \u003cli\u003eEnsure that the total probe length (1.0 m) and extension cable length (typically 4.0 m) match the 5.0-meter system length designated on the 3300 XL Proximitor Sensor.\u003c\/li\u003e\n  \u003cli\u003eEnsure the ClickLoc connection is fully protected with the pre-installed connector protector to prevent ingress of industrial oils, water, or other process contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e Complies with European Community Directive 2014\/30\/EU, EN 61000-6-2 (Industrial Immunity), and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with EU Directive 2011\/65\/EU and China RoHS regulations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 05):\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T5...T1 Ga; Ex ia IIIC T90degC...T280degC Dc; Ex nA IIC T5...T1 Gc; Ex ec IIC T5...T1 Gc.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eNorth America (CSA):\u003c\/strong\u003e Class I, Zone 0, AEx ia IIC T5...T1 Ga; Class I, Division 1, Groups A, B, C, and D; Class I, Division 2, Groups A, B, C, and D.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526499179,"sku":"330701-00-25-10-11-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330701-00-25-10-11-05-11-mm-proximity-probes-qhsolr2psmx_89d3c839-1ddd-4359-a597-2e3ae6843595.jpg?v=1765440287"},{"product_id":"bently-nevada-330190-080-01-05-3300-xl-etr-extension-cable","title":"Bently Nevada 330190-080-01-05 3300 XL ETR Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 080 (8.0 m length) and Option 01 (integrated PFA-jacketed armor) define this specific 3300 XL ETR extension cable configuration — \u003cstrong\u003e330190-080-01-05\u003c\/strong\u003e. This cable is a component of the 3300 XL 8 mm Extended Temperature Range (ETR) proximity transducer system, which is used for non-contact shaft vibration and position measurements on rotating machinery. The 3300 XL ETR system is designed for severe industrial environments where temperatures exceed standard operating limits.\u003c\/p\u003e\n\n\u003cp\u003eThis armored cable configuration features a length of 8.0 meters (26.2 feet) and is constructed with a flexible stainless steel armor sheath over PFA insulation. The armoring guards the core coaxial line against crushing, pinching, and abrasive wear in harsh mounting paths. With Option 05 certifications, this cable complies with CSA, ATEX, and IECEx requirements for installation in hazardous area locations, making it suitable for chemical processing, oil refineries, and power generation machinery monitoring loops.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8.0 Meter Cable Length\u003c\/strong\u003e: Part segment 080 specifies an 8.0-meter physical length to complete the matching transducer loop requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Armoring\u003c\/strong\u003e: Segment 01 features stainless steel protective armor with a PFA outer jacket for robust physical defense.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Rating\u003c\/strong\u003e: PFA insulation is rated for extreme operating conditions between -52 and +260 Celsius.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location Approvals\u003c\/strong\u003e: Segment 05 provides North American and international ATEX, IECEx, and CSA safety certifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGold-Plated ClickLoc Connectors\u003c\/strong\u003e: Secure miniature male and female coaxial termination ends prevent signal loss without requiring specialized torque wrenches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical application environments for this cable configuration include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine bearing housing vibration and position monitoring loops.\u003c\/li\u003e\n\u003cli\u003eHigh-temperature refinery compressor shaft displacement systems.\u003c\/li\u003e\n\u003cli\u003eHot-end machinery and steam turbine casing monitoring.\u003c\/li\u003e\n\u003cli\u003eZone-rated industrial processing plants requiring explosion-proof instrumentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330190-080-01-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL ETR armored extension cable, 8.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Armor and Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eArmored cable (stainless steel armor with PFA jacket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, and IECEx approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification Parameter\u003c\/th\u003e\n\u003cth\u003eValue \/ Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330190-080-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtended Temperature Range (ETR) Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePFA (Perfluoroalkoxy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible stainless steel armor with PFA outer jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +260 Celsius (-62 to +500 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Armor Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.67 mm (0.302 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connectors (1 male, 1 female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.87 kg (1.92 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm x 280 mm x 45 mm (H x W x D) (coiled bundle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection End\u003c\/th\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eTarget Connection Point\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature female coaxial ClickLoc connector\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor connector sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish safe signal path integrity and avoid mechanical stress, please follow these guidelines:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius\u003c\/strong\u003e: Do not exceed the minimum cable bend radius of 50.8 mm (2.0 in) for the armored section of this extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Torque\u003c\/strong\u003e: Connect the miniature coaxial ends finger-tight only. Do not use pliers or torque keys as this may strip the gold-plated threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Areas\u003c\/strong\u003e: Install the cable runs in compliance with the barrier and wiring layout drawings specified by Bently Nevada approval guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Standard\u003c\/th\u003e\n\u003cth\u003eApproval Grade \/ Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Areas (Option 05)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC T5...T1 Ga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Sparking \/ Increased Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx nA IIC T5...T1 Gc \/ Ex ec IIC T5...T1 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDust Ignition Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia IIIC T90 Celsius ... T280 Celsius Dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526859627,"sku":"330190-080-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330190-080-01-05-extension-cable-l5xnio4gezn_8a3f64de-d10a-4ef4-bec8-3eb01badeee5.jpg?v=1765440290"},{"product_id":"bently-nevada-330103-00-05-05-01-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-00-05-05-01-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0 mm unthreaded length), Option 05 (50 mm case length), and Option 05 (0.5 m total length) specify this \u003cstrong\u003e3300 XL 8 mm proximity probe\u003c\/strong\u003e configuration — \u003cstrong\u003e330103-00-05-05-01-05\u003c\/strong\u003e, which features an unarmored standard metric case and a coaxial ClickLoc connector with a pre-installed connector protector.\u003c\/p\u003e\n\u003cp\u003eIn contrast to variants with longer cable runs (such as 1.0 m or 2.0 m options) or armored protection sleeves, this 330103 configuration provides a compact 0.5-meter standard cable solution. The integrated connector protector guards the ClickLoc terminal from mechanical damage and moisture intrusion, making it suitable for confined spaces inside machine housings. With a fully threaded 50 mm case and zero unthreaded length, the probe offers maximum mounting adjustability within standard metric brackets.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM10 x 1 thread body style without protective armor.\u003c\/li\u003e\n  \u003cli\u003e0 mm unthreaded length for direct flush-mounting applications.\u003c\/li\u003e\n  \u003cli\u003e50 mm overall case length provides mounting depth flexibility.\u003c\/li\u003e\n  \u003cli\u003e0.5 meter (1.6 feet) total length standard coaxial cable.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector supplied with a pre-installed connector protector.\u003c\/li\u003e\n  \u003cli\u003eCertified for hazardous area installations under CSA, ATEX, and IECEx approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eIndustrial machinery vibration monitoring and axial position measurements in rotating equipment. Commonly used on steam turbines, gas turbines, centrifugal compressors, pumps, and generators to track shaft displacement, differential expansion, and keyphasor reference signals.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n      \u003ctd\u003e330103-00-05-05-01-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe, M10 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e50 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (1.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330103-00-05-05-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Size\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eNone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Length\u003c\/td\u003e\n      \u003ctd\u003e50 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Length\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (1.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Protector\u003c\/td\u003e\n      \u003ctd\u003eIncluded (Option 01)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003eStandard 75 ohm coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e8.0 mm (0.31 inches)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature (Probe)\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDifferential Pressure Seal\u003c\/td\u003e\n      \u003ctd\u003eSeals up to 7.0 bar (100 psi)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Diameter\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 inches)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.16 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e130 mm x 130 mm x 40 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Component\u003c\/th\u003e\n      \u003cth\u003eSpecifications\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc with gold-plated contact pins\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCoaxial Cable\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm low-loss shielded cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the probe in M10 x 1 threaded holes using a standard metric bracket. Verify that the thread engagement does not exceed the limit of 15 mm to prevent binding. Verify that the probe tip has clear space from surrounding metal (at least 1.5 times the probe tip diameter) to prevent side-loading or cross-talk. Install the connector protector properly to seal the coaxial junction from fluid ingress and contamination. Maintain a minimum bend radius of 25.4 mm (1.0 inch) for the probe coaxial cable.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eCSA, ATEX, IECEx approvals for use in hazardous areas (Intrinsically Safe and Non-Incendive configurations).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527056235,"sku":"330103-00-05-05-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-00-05-05-01-05-proximity-probes-4hjd0umhvtz_c64522d7-4377-486f-b15b-3701f41324a4.jpg?v=1765440293"},{"product_id":"bently-nevada-330104-05-14-50-01-05-3300-xl-armored-proximity-probe","title":"Bently Nevada 330104-05-14-50-01-05 3300 XL Armored Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330104-05-14-50-01-05\u003c\/strong\u003e: 3300 XL 8 mm \u003cstrong\u003eproximity probe\u003c\/strong\u003e with M10 x 1 metric thread, protective stainless steel armor, 50 mm unthreaded length, 140 mm overall case length, 5.0-meter total cable length, ClickLoc connector with connector protector, and CSA\/ATEX\/IECEx approvals.\u003c\/p\u003e\n\u003cp\u003eThis configuration incorporates standard flexible AISI 302 or 304 stainless steel armor with an outer FEP jacket to defend the 75-ohm triaxial cable against physical abrasion and mechanical stress in challenging industrial environments. Unlike unarmored models or short-lead variants, this 5.0-meter probe is designed specifically for operation in physical configurations matching 5.0-meter Proximitor sensors without requiring separate extension cables, reducing connection points in the measurement chain.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM10 x 1 metric thread configuration with a 140 mm case length and 50 mm unthreaded portion.\u003c\/li\u003e\n  \u003cli\u003eIntegrated stainless steel protective armor shielding the 75-ohm triaxial cable from physical wear.\u003c\/li\u003e\n  \u003cli\u003e5.0-meter total system length designed specifically for direct connection to 5-meter Proximitor sensors.\u003c\/li\u003e\n  \u003cli\u003eGold-plated miniature coaxial ClickLoc connector with an integrated connector protector.\u003c\/li\u003e\n  \u003cli\u003eHazardous area approvals including CSA, ATEX, and IECEx for intrinsically safe installations.\u003c\/li\u003e\n  \u003cli\u003eMolded polyphenylene sulfide (PPS) probe tip offering chemical and environmental resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on high-speed rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery protection systems for steam turbines, gas turbines, compressors, and pumps.\u003c\/li\u003e\n  \u003cli\u003eHazardous area machinery monitoring in oil and gas refineries, petrochemical plants, and power generation facilities.\u003c\/li\u003e\n  \u003cli\u003eOver-speed detection and industrial turbine housing expansion monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330104\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, M10 x 1 thread, with armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e50 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e14\u003c\/td\u003e\n      \u003ctd\u003e140 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) overall length (for 5 m Proximitor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals (Intrinsically Safe \/ Non-Incendive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330104-05-14-50-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy-current proximity probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 mm (0.31 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e140 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Armor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 or 304 SST with FEP outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 degC (-62 to +350 Fahrenheit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDesigned to seal differential pressure up to 7.0 bar (100 psi) between tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) maximum probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.73 +\/- 0.50 ohms (center conductor to outer conductor for 5.0 m length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e250 mm x 250 mm x 45 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.42 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInstall per Bently Nevada drawing 141092 for intrinsically safe (ia) installations or drawing 140979 for non-incendive (nA\/ec) environments.\u003c\/li\u003e\n  \u003cli\u003eUse a maximum torque rating of 22.6 N-m (200 in-lb) when mounting the probe case into the bracket or housing (reduce to 7.5 N-m \/ 66 in-lb for the first three threads).\u003c\/li\u003e\n  \u003cli\u003eEnsure the minimum cable bend radius of 25.4 mm (1.0 in) is maintained during routing.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed 15 mm of thread engagement when installing the M10 x 1 probe case.\u003c\/li\u003e\n  \u003cli\u003eSecure the miniature coaxial ClickLoc connector hand-tight; the integrated connector protector prevents mechanical disconnects and moisture ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA, ATEX, IECEx Approvals (Ex ia IIC T5...T1 Ga, Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc)\u003c\/li\u003e\n  \u003cli\u003eRoHS Compliant (2011\/65\/EU)\u003c\/li\u003e\n  \u003cli\u003eCE Compliant (EMC Directive 2014\/30\/EU)\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: SIL 2 (HFT = 0), SIL 3 (HFT = 1) certified when part of a complete 3300 XL system\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527154539,"sku":"330104-05-14-50-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330104-05-14-50-01-05-probes-kf1kfsgarjd_ee4e31e6-f6fa-4e98-8450-a93543370ae6.jpg?v=1765440294"},{"product_id":"bently-nevada-330101-00-50-15-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-50-15-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-00-50-15-02-05\u003c\/strong\u003e is a high-precision, non-contact \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e belonging to the industry-standard 3300 XL series. This specific configuration is distinguished by having a completely threaded case with 0.0 inches of unthreaded length (unthreaded option 00) and an overall case length of 5.0 inches (option 50). To ensure precise signal integrity without the added weight or bulk of stainless steel armor, this probe features a 1.5-meter (4.9 feet) standard cable (option 15) terminated with a miniature coaxial ClickLoc connector (option 02). Additionally, it is certified with CSA, ATEX, and IECEx agency approvals (option 05) for hazardous locations.\u003c\/p\u003e\n\u003cp\u003eThis eddy-current transducer is designed to measure static shaft position and dynamic vibration on critical rotating machinery. By pairing with a compatible 3300 XL Proximitor sensor and an extension cable, it forms a complete 3300 XL monitoring chain. The probe is engineered to withstand extreme temperatures and harsh industrial fluids, making it ideal for continuous machinery protection in demanding power generation, oil and gas, and petrochemical processes.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Threaded 5.0-Inch Case:\u003c\/strong\u003e Designed with zero unthreaded length (0.0 in) for versatile mounting depth adjustment inside threaded machine housings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Non-Armored Cable:\u003c\/strong\u003e Includes a lightweight, high-temperature standard cable with a 1.5-meter total length for streamlined cable routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Miniature Coaxial Connector:\u003c\/strong\u003e Features a gold-plated ClickLoc connector that resists vibration loosening while simplifying connections to the extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Certified:\u003c\/strong\u003e Comes pre-approved with CSA, ATEX, and IECEx ratings, ensuring safe operation in Zone 0, Zone 1, and Division 1 environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Material Construction:\u003c\/strong\u003e Built with a polyphenylene sulfide (PPS) probe tip and a stainless steel body to seal against moisture and high differential pressures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-50-15-02-05 proximity probe is ideal for a wide range of critical machinery monitoring tasks, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration measurements in steam and gas turbine bearings.\u003c\/li\u003e\n\u003cli\u003eThrust (axial) position monitoring for compressor and pump rotors.\u003c\/li\u003e\n\u003cli\u003eShaft eccentricity and speed measurements on major industrial rotating machines.\u003c\/li\u003e\n\u003cli\u003ePermanently mounted machinery protection systems compliant with API 670 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis Bently Nevada probe is custom-ordered according to specific physical and electrical options. The table below decodes the options configured on this specific SKU:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Code\u003c\/th\u003e\n\u003cth\u003eConfigured Value\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330101\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0.0 inches (fully threaded body)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 inches overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e1.5 meters (4.9 feet) total probe length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Connector\/Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330101-00-50-15-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Size\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eDisplacement (proximity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Principle\u003c\/td\u003e\n\u003ctd\u003eEddy current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils), from approximately 0.25 to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Voltage\u003c\/td\u003e\n\u003ctd\u003e-9 Vdc (approximately 1.27 mm or 50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Probe DC Resistance (R_PROBE)\u003c\/td\u003e\n\u003ctd\u003e7.73 +\/- 0.50 Ohms (center conductor to outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating and Storage Temperature (Standard Probe)\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Sealing Limit\u003c\/td\u003e\n\u003ctd\u003eSealed with Viton O-ring between probe tip and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Resistance\u003c\/td\u003e\n\u003ctd\u003eLess than 3% change in Average Scale Factor (ASF) under 93% humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eGold-plated miniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal system performance and longevity of the Bently Nevada 330101 probe, adhere to the following engineering and installation instructions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Maximum recommended thread engagement is 0.563 inches (14 mm) to prevent binding during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Setting:\u003c\/strong\u003e Mount the probe with the appropriate physical gap (typically -9 Vdc or 1.27 mm \/ 50 mils) corresponding to the system calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Ensure the probe cable is routed away from high-voltage wiring, and employ proper shielding and grounding techniques in accordance with standard industrial vibration monitoring practices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Standard probes operating below -34 degC (-30 degF) may experience a degraded pressure seal. Proper insulation or casing protection is advised in sub-zero locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330101-00-50-15-02-05 configuration includes the following major agency approvals:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Class I, Div 1, Groups A, B, C, D; Class II, Div 1, Groups E, F, G; Class III\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T5...T1 Ga; Ex ia IIIC T90 Celsius...T280 Celsius Dc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Compliant with applicable European Union directives\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527220075,"sku":"330101-00-50-15-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-50-15-02-05-proximity-probes-rzcvy3d10ha_fd737c6a-95f9-4ce2-a013-92f2f5eefa36.jpg?v=1765440295"},{"product_id":"bently-nevada-330130-060-02-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-060-02-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nOption 060 (6.0 meters cable length) and Option 02 (standard cable with integrated fluorosilicone connector protector) specify this \u003cstrong\u003e3300 XL Standard Extension Cable\u003c\/strong\u003e configuration — \u003cstrong\u003e330130-060-02-05\u003c\/strong\u003e. This cable provides the physical and electrical transmission link between a 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor in non-contact displacement monitoring chains. In a complete transducer system, the total length of the probe and extension cable must match the required total system length of the Proximitor sensor (typically 5.0 or 9.0 meters).\n\nThe pre-installed connector protector (Option 02) provides environmental sealing for the gold-plated ClickLoc connector joint, preventing fluid, oil, dust, and moisture ingress in aggressive machinery environments. Option 05 designates the certificate package for explosive or hazardous atmospheres, supporting installation requirements across globally certified process environments.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 060 designates a 6.0 meters (19.7 feet) cable length, forming a matched 7.0 or 9.0 meters system when combined with the corresponding probe.\u003c\/li\u003e\n  \u003cli\u003eOption 02 includes standard cable pre-equipped with a fluorosilicone connector protector to seal and guard the connector joint against environmental contaminants.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides hazardous area approvals including CSA, ATEX, and IECEx certifications.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass and beryllium copper ClickLoc connectors provide positive locking with simple finger-tightening.\u003c\/li\u003e\n  \u003cli\u003eFluorinated Ethylene Propylene (FEP) cable insulation and outer jacket provide chemical, oil, and moisture resistance.\u003c\/li\u003e\n  \u003cli\u003eCable electrical resistance measures 1.32 ohms +\/- 0.21 ohms for the core conductor and 0.39 ohms +\/- 0.08 ohms for the outer jacket conductor over the 6.0 meters length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on high-speed rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eTurbine, generator, compressor, and pump protective monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eEnvironments requiring certified electrical apparatus for explosive or hazardous gas zones.\u003c\/li\u003e\n  \u003cli\u003eMachinery installations exposed to lubricating oils, hydraulic fluids, and severe moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Code\u003c\/th\u003e\n      \u003cth\u003eValue on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330130-060-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable, 6.0 m length, standard cable with connector protector, CSA\/ATEX\/IECEx approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length Option\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector Protector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-060-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard triaxial coaxial cable with FEP insulation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with connector protector (Option 02)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass and gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCore Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.32 ohms +\/- 0.21 ohms (typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Jacket Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.39 ohms +\/- 0.08 ohms (typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx (Option 05)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutside Diameter of Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.7 mm maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutside Diameter of Connector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12.4 mm maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e200 mm x 200 mm x 30 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector End\u003c\/th\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Connection End\u003c\/td\u003e\n      \u003ctd\u003eMiniature female coaxial ClickLoc\u003c\/td\u003e\n      \u003ctd\u003eConnects to the miniature male coaxial connector of the proximity probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Connection End\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc\u003c\/td\u003e\n      \u003ctd\u003eConnects to the female coaxial connector of the Proximitor sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the combined length of the proximity probe and the 6.0 m extension cable equals the calibrated system length specified on the Proximitor sensor label.\u003c\/li\u003e\n  \u003cli\u003eTighten the coaxial ClickLoc connectors finger-tight until they physically click; do not use mechanical tools.\u003c\/li\u003e\n  \u003cli\u003eSlide and fully seat the fluorosilicone connector protector sleeve over the mated connector joint to establish a moisture-proof seal.\u003c\/li\u003e\n  \u003cli\u003eObserve a minimum bend radius of 25.4 mm (1.0 inch) for the FEP coaxial cable during routing.\u003c\/li\u003e\n  \u003cli\u003eSecure the extension cable using non-conductive, oil-resistant cable ties or protective conduit to prevent physical wear and high-voltage interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA Certified: Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2; Class III\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: Zone 0, Zone 1, and Zone 2 explosive gas atmospheres\u003c\/li\u003e\n  \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527613291,"sku":"330130-060-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-060-02-05-extension-cable-0bunup5hoxy_c848148b-b374-40cf-9095-109af2168f0b.jpg?v=1765440300"},{"product_id":"bently-nevada-330103-00-15-10-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-00-15-10-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330103-00-15-10-02-05\u003c\/strong\u003e: 3300 XL 8 mm proximity probe with M10 x 1 metric thread, configured without armor, featuring 0 mm unthreaded length (Option 00), 150 mm overall case length (Option 15), 1.0 meter total length (Option 10), and a Miniature ClickLoc coaxial connector on standard cable without connector protection (Option 02). This configuration includes Option 05 for CSA, ATEX, and IECEx agency approvals.\u003c\/p\u003e\n\u003cp\u003eThis unarmored metric probe variant is used for non-contact eddy-current shaft displacement and vibration measurements within a 3300 XL monitoring system. Unlike variants equipped with stainless steel armor or FluidLoc cable options, this configuration employs standard coaxial cabling and a standard unarmored sleeve, and is designed to operate in systems requiring metric M10 x 1 mounting threads and 150 mm of thread depth.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM10 x 1 metric thread profile with a case length of 150 mm\u003c\/li\u003e\n  \u003cli\u003e0 mm unthreaded length maximizing the threaded engagement portion\u003c\/li\u003e\n  \u003cli\u003e1.0 meter total system length for direct connection or use with standard extension cables\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector with gold-plated brass components\u003c\/li\u003e\n  \u003cli\u003eStandard coaxial cable configuration without external protective armor\u003c\/li\u003e\n  \u003cli\u003eAgency approval option 05 certifying suitability for CSA, ATEX, and IECEx hazardous area installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on fluid-film bearing machines\u003c\/li\u003e\n  \u003cli\u003eKeyphasor reference and speed measurements on industrial machinery\u003c\/li\u003e\n  \u003cli\u003eIndustrial rotating machinery protection in oil and gas, petrochemical, and power generation plants\u003c\/li\u003e\n  \u003cli\u003eMonitoring radial dynamic motion and axial shaft position\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-00-15-10-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe, M10 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n      \u003ctd\u003e150 mm case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-00-15-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e150 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 degC (-62 to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSealed up to 7.0 bar (100 psi)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) when paired with 3300 XL Proximitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) from probe tip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e150 mm x 17 mm x 17 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.15 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe probe cable is terminated with a miniature gold-plated male ClickLoc coaxial connector that connects directly to a standard 3300 XL extension cable or Proximitor sensor.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the mounting thread is tapped to M10 x 1. The maximum thread engagement length is 15 mm to prevent binding. A class-matched thread should be used for all internal threads. Do not exceed the maximum recommended torque during installation. For hazardous area installations, maintain grounding and shielding continuity in accordance with the system installation drawings.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis probe configuration complies with the following certifications under Option 05:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA (Class I, Division 1 and 2, Groups A, B, C, D)\u003c\/li\u003e\n  \u003cli\u003eATEX (Zone 0, 1, 2, Group IIC)\u003c\/li\u003e\n  \u003cli\u003eIECEx (Zone 0, 1, 2, Group IIC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527809899,"sku":"330103-00-15-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-00-15-10-02-05-3300-xl-8-mm-probe-dcytptlhlmy_08d170d8-0aa4-4c47-9f72-bc3a4ee97ad8.jpg?v=1765440304"},{"product_id":"bently-nevada-330180-x1-05mod-145193-01-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05MOD:145193-01 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-X1-05MOD:145193-01\u003c\/strong\u003e: This 3300 XL Proximitor Sensor is configured with Option X1 for DIN-rail mounting, Option 05 for multiple hazardous area agency approvals, and is custom-calibrated under modification 145193-01 for non-standard target materials.\u003c\/p\u003e\n\u003cp\u003eIn contrast to standard 330180 variants calibrated for AISI 4140 steel, this Proximitor sensor includes factory recalibration circuitry to maintain precise eddy-current measurement linearity on specific non-standard alloys. It integrates oscillator and detection electronics to condition proximity probe signals into a continuous displacement output, directly compatible with machinery protection monitors such as the Bently Nevada 3500 system.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-rail mount form factor specified by option X1 for secure electrical enclosure mounting\u003c\/li\u003e\n\u003cli\u003eMultiple hazardous area approvals under option 05 including ATEX, IECEx, and CSA intrinsic safety standards\u003c\/li\u003e\n\u003cli\u003eCustom target material calibration under Bently Nevada engineering modification MOD 145193-01\u003c\/li\u003e\n\u003cli\u003eConverts eddy-current RF signals into a continuous voltage output proportional to target distance\u003c\/li\u003e\n\u003cli\u003eSeamlessly integrates with 3300 XL 5mm\/8mm 9m proximity probes and extension cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and axial position monitoring on high-speed industrial machinery\u003c\/li\u003e\n\u003cli\u003eHeavy industrial applications in power generation, oil and gas, petrochemical, and chemical processing\u003c\/li\u003e\n\u003cli\u003eSpecialized rotor dynamic analysis on turbomachinery utilizing non-standard shaft materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145193-01\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5mm\/8mm Proximitor Sensor, 9-Meter System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length and Mounting\u003c\/td\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eModification, DIN Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals (CSA, ATEX, IECEx intrinsically safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModification Number\u003c\/td\u003e\n\u003ctd\u003eMOD:145193\u003c\/td\u003e\n\u003ctd\u003eTarget material recalibration modification family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial Option\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eOption 01 under custom modification 145193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145193-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5mm\/8mm 9m proximity probe and extension cable systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mount (Option X1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) linear analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e10 to 90 mils (0.25 to 2.30 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -24 Vdc input power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.3 mm x 61.2 mm x 103.1 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon \/ Circuit ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eOutput displacement signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVTG (PROX)\u003c\/td\u003e\n\u003ctd\u003ePower supply (-24 Vdc input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoaxial Connector\u003c\/td\u003e\n\u003ctd\u003eConnects to 3300 XL extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount securely on a standard 35 mm DIN rail in an environmentally protected enclosure.\u003c\/li\u003e\n\u003cli\u003eEnsure proper electrical isolation and shield grounding to prevent interference from external noise.\u003c\/li\u003e\n\u003cli\u003eConnect coaxial cable from the extension cable to the Proximitor coaxial connector, ensuring it is finger-tight.\u003c\/li\u003e\n\u003cli\u003eMaintain an appropriate probe-to-target gap matching the linear range of 10 to 90 mils.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\/IECEx Intrinsically Safe (Option 05)\u003c\/li\u003e\n\u003cli\u003eCSA Class I, Division 1, Groups A, B, C, D (Option 05)\u003c\/li\u003e\n\u003cli\u003eCE Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528006507,"sku":"330180-X1-05 MOD: 145193-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145193-01-3300-xl-proximitor-sensor-5w11ezz4jnd_f4825ce2-814e-4ef2-a538-253f1ab12228.jpg?v=1765440307"},{"product_id":"bently-nevada-330102-00-40-50-02-00-3300-xl-8-mm-armored-proximity-probe","title":"Bently Nevada 330102-00-40-50-02-00 3300 XL 8 mm Armored Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0.0 in unthreaded) and Option 02 (ClickLoc, no connector protector) specify this 3300 XL 8 mm probe configuration — \u003cstrong\u003e330102-00-40-50-02-00\u003c\/strong\u003e. This armored proximity probe features a 4.0-inch case length (Option 40) and a 5.0-meter total length (Option 50), designed without hazardous area approvals (Option 00).\u003c\/p\u003e\n\u003cp\u003eUnlike non-armored siblings (such as the 330101 series) or configurations with connector protectors (Option 01), the 330102 model utilizes flexible AISI 302\/304 stainless steel armor with an FEP outer jacket to protect the coaxial cable from physical abrasion and chemical exposure. Additionally, the 5.0-meter length variant is calibrated specifically for 5-meter Proximitor systems, bypassing the need for separate extension cables in short-run installations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eStandard 3\/8-24 UNF threaded body made from durable AISI 303\/304 stainless steel.\u003c\/li\u003e\n  \u003cli\u003eOption 00 unthreaded length providing 0.0 in (0 mm) of unthreaded shaft, maximizing thread engagement in the mounting bracket.\u003c\/li\u003e\n  \u003cli\u003eOption 40 case length providing a 4.0 in (101.6 mm) overall threaded case for extended mounting reach.\u003c\/li\u003e\n  \u003cli\u003eOption 50 total length providing 5.0 m (16.4 ft) of system length, intended for direct integration with 5-meter Proximitor sensors.\u003c\/li\u003e\n  \u003cli\u003eOption 02 connector option providing a miniature gold-plated coaxial ClickLoc connector with standard 75-ohm FEP insulated triaxial cable.\u003c\/li\u003e\n  \u003cli\u003eOption 00 agency approval selection, suitable for non-hazardous locations or standard industrial applications.\u003c\/li\u003e\n  \u003cli\u003eIntegrated flexible AISI 302\/304 stainless steel armor with an FEP outer jacket to protect the cable in abrasive industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis transducer is primarily used for non-contact shaft vibration and axial position measurements in rotating machinery, including steam turbines, gas turbines, compressors, pumps, and generators. The integrated steel armor is ideal for applications where the routing path exposes the cable to mechanical wear, sharp edges, or environmental contaminants.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330102-00-40-50-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe, 3\/8-24 UNF thread, with armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e40\u003c\/td\u003e\n      \u003ctd\u003e4.0 in (101.6 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330102-00-40-50-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 in (101.6 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 or 304 SST with FEP outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.68 mm (standard cable), 7.67 mm (with armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature gold-plated coaxial ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5-meter 3300 XL Proximitor systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 degC (-62 to +350 Fahrenheit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDifferential pressure seal up to tip rating (Viton O-ring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.73 ohms (typical for 5.0 m length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Max)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) probe case to lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e250 mm x 250 mm x 45 mm (H x W x D) (typical coiled package)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.65 kg (650 g)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the probe is properly gapped using a voltmeter or specialized gap calibration tool before finalizing the mechanical mounting. Maintain a minimum cable bend radius of 25.4 mm (1.0 in) to protect the internal FEP insulation. When tightening the probe case into the bracket, do not exceed the recommended torque limits. Always route the armored cable away from high-temperature exhaust paths and electrical power cables to mitigate thermal damage and electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis series meets the following standards when part of a qualified 3300 XL Transducer system:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEMC: European Community Directive 2014\/30\/EU, standards EN 61000-6-2 and EN 61000-6-4.\u003c\/li\u003e\n  \u003cli\u003eRoHS: European Community Directive 2011\/65\/EU and China RoHS (15-year EFUP designation).\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: SIL 2 certified (HFT=0), SIL 3 capable (HFT=1) when configured as part of a safety instrumented system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528235883,"sku":"330102-00-40-50-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330102-00-40-50-02-00-proximity-probes-gotwhwpcq4x_681e7c20-17d7-42f3-beba-ea4aa683316f.jpg?v=1765440311"},{"product_id":"bently-nevada-330730-040-01-05-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-040-01-05 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330730-040-01-05\u003c\/strong\u003e specifies this 3300 XL 11 mm extension cable configuration, featuring a 4.0 meter cable length, protective stainless steel armor, and a multiple agency approvals package. This cable is used within the 3300 XL 11 mm Proximity Transducer System, connecting the 3300 XL 11 mm proximity probe to the 3300 XL 11 mm Proximitor sensor for non-contact shaft vibration, axial position, and differential expansion monitoring.\u003c\/p\u003e\n\u003cp\u003eCompared to standard non-armored models like the 330730-040-00-05, this configuration incorporates flexible AISI 302 stainless steel armor with an outer FEP jacket to withstand mechanical abrasion, physical impact, and harsh industrial environments. While unarmored configurations are lighter and more flexible for clean environments, the armored jacket is essential in open industrial installations where cables are routed near sharp edges or high-traffic areas.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4.0 meter cable length (Option 040) designed to combine with a 1.0 meter probe to achieve a 5.0 meter total system length.\u003c\/li\u003e\n  \u003cli\u003eAISI 302 stainless steel armor (Option 01) with an outer FEP jacket for mechanical protection against abrasion and physical impacts.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass coaxial connectors providing secure, low-loss electrical contact.\u003c\/li\u003e\n  \u003cli\u003eMultiple agency approvals (Option 05) supporting cNRTLus, ATEX, and IECEx certifications for hazardous area installations.\u003c\/li\u003e\n  \u003cli\u003eTriaxial 75 ohm cable construction with fluoroethylene propylene (FEP) insulation.\u003c\/li\u003e\n  \u003cli\u003e25.4 mm (1.0 in) minimum bend radius allowing flexible routing in tight conduits and enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical application environments include rotating machinery protection in heavy industries such as oil and gas, power generation, petrochemicals, and water treatment:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial thrust position monitoring.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor rotor position and casing differential expansion measurements.\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor rod drop and rod position tracking.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator shaft runout and zero-speed monitoring.\u003c\/li\u003e\n  \u003cli\u003eBalance of plant rotating machinery protection in hazardous area environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from Manufacturer Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330730-040-01-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eArmored cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (cNRTLus, ATEX, and IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330730-040-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Length\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 SST with FEP outer jacket (armored cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Material\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCore dc Resistance\u003c\/td\u003e\n      \u003ctd\u003e0.3 +\/- 0.1 ohms (center conductor to center conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eJacket dc Resistance\u003c\/td\u003e\n      \u003ctd\u003e1.0 +\/- 0.25 ohms (coaxial conductor to coaxial conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Maximum Rated)\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 pounds) at probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Torque\u003c\/td\u003e\n      \u003ctd\u003eRecommended: finger tight; Maximum: 0.565 N-m (5 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnit Weight\u003c\/td\u003e\n      \u003ctd\u003e140 g\/m (1.5 oz\/ft) for armored cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating \u0026amp; Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMiniature female coaxial ClickLoc connector\u003c\/td\u003e\n      \u003ctd\u003eMates with 3300 XL 11 mm proximity probe coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n      \u003ctd\u003eMates with 3300 XL 11 mm Proximitor sensor coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eKeep the minimum bend radius of the armored cable to 25.4 mm (1.0 in) or greater during routing to prevent core damage.\u003c\/li\u003e\n  \u003cli\u003eHand-tighten coaxial connectors to ensure proper electrical mating; do not exceed the maximum torque limit of 0.565 N-m (5 in-lb).\u003c\/li\u003e\n  \u003cli\u003eProtect the connector junction using connector protectors or self-fusing silicone tape to prevent oil, moisture, and dust ingress.\u003c\/li\u003e\n  \u003cli\u003eDo not use silicone tape in environments where the cable connection will be directly exposed to turbine oil.\u003c\/li\u003e\n  \u003cli\u003eEnsure that the sum of the extension cable length and the probe length matches the total length rated on the Proximitor sensor (e.g., 4.0 m cable + 1.0 m probe equals a 5.0 m system).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEMC Directive 2014\/30\/EU, Standards EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU with China RoHS EFUP designation of 15 years\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: SIL 2 (HFT=0), SIL 3 (HFT=1) certified when used in a complete safety-instrumented system\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Approvals (Option 05):\n    \u003cul\u003e\n      \u003cli\u003ecNRTLus (Intrinsically Safe): Class I, Zone 0: AEx\/Ex ia IIC T5...T1 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n      \u003cli\u003ecNRTLus (Non-incendive): Class I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D\u003c\/li\u003e\n      \u003cli\u003eATEX\/IECEx: Ex ia IIC T5...T1 Ga (EPL Ga), Ex ia IIIC T90C...T280C Dc (EPL Dc), Ex nA\/ec IIC T5...T1 Gc (EPL Gc)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528399723,"sku":"330730-040-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330730-040-01-05-extension-cable-5ycpb2ud2io_f89520df-dbca-4e81-8b28-ab3a929576a8.jpg?v=1765440313"},{"product_id":"bently-nevada-330704-00-50-10-01-05-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330704-00-50-10-01-05 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330704-00-50-10-01-05\u003c\/strong\u003e: 3300 XL 11 mm proximity probe with metric M14 x 1.5 thread and stainless steel armor. Option 00 specifies a 0 mm unthreaded length, Option 50 defines a 50 mm overall case length, and Option 10 indicates a 1.0 meter (3.3 feet) total probe length. It features a miniature coaxial ClickLoc connector with a pre-installed connector protector on a standard 75 ohm FEP-insulated cable (Option 01), combined with multiple international hazardous area certifications (Option 05).\u003c\/p\u003e\n\u003cp\u003eThis eddy-current proximity probe belongs to the 3300 XL 11 mm Proximity Transducer System, which is used for non-contacting vibration and displacement measurements on fluid film bearing machines. The protective flexible AISI 302 stainless steel armor shields the cable from physical wear and harsh industrial environments, contrasting with non-armored variants like the 330703 probe. The probe connects to a 3300 XL 11 mm extension cable and a 3300 XL 11 mm Proximitor Sensor to form a complete 5-meter or 9-meter measurement system.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 00 (0 mm unthreaded length) and Option 50 (50 mm overall case length) provide a standard metric M14 x 1.5 threaded profile.\u003c\/li\u003e\n\u003cli\u003eOption 10 specifies a 1.0 meter (3.3 feet) total probe length, designed to connect directly to compatible 3300 XL extension cables.\u003c\/li\u003e\n\u003cli\u003eOption 01 includes a miniature coaxial ClickLoc connector along with a fluorosilicone connector protector to guard the connection from environmental contaminants.\u003c\/li\u003e\n\u003cli\u003eOption 05 provides multiple approvals for hazardous environments, including CSA, ATEX, and IECEx intrinsic safety and non-incendive ratings.\u003c\/li\u003e\n\u003cli\u003eFlexible AISI 302 stainless steel armor with FEP outer jacket offers robust mechanical protection for the triaxial probe cable.\u003c\/li\u003e\n\u003cli\u003ePolyphenylene sulfide (PPS) tip material resists chemical erosion and high temperatures in rotating machinery casings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical applications for this transducer system configuration include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAxial (thrust) position measurements on steam turbines and turbomachinery.\u003c\/li\u003e\n\u003cli\u003eShaft radial vibration measurements on fluid film bearing machines.\u003c\/li\u003e\n\u003cli\u003eRamp differential expansion measurements on steam turbines.\u003c\/li\u003e\n\u003cli\u003eRod position or rod drop measurements on industrial reciprocating compressors.\u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed, and phase reference (Keyphasor) signal generation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330704-00-50-10-01-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Probe, M14 x 1.5 thread, with armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e50 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total probe length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx intrinsic safety and non-sparking\/non-incendive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003e330704-00-50-10-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer System\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003eM14 x 1.5 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 stainless steel armor with FEP outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), beginning at approximately 0.5 mm (20 mils) from target to 4.5 mm (180 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10% over the 4.0 mm linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.10 mm (+\/-4 mils) at standard temperature; Less than +\/-0.15 mm (+\/-6 mils) over probe temp range -35 degC to +120 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Cable Specification\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe dc Resistance (R_PROBE)\u003c\/td\u003e\n      \u003ctd\u003e5.9 +\/- 0.5 ohms (center conductor to outer conductor for 1.0 m probe)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Maximum Rated)\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to probe lead; 270 N (60 lb) at probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in) with or without SST armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Rated Torque\u003c\/td\u003e\n      \u003ctd\u003e63.3 N-m (560 in-lb); Recommended installation torque: 21.1 N-m (187 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector-to-Connector Torque\u003c\/td\u003e\n      \u003ctd\u003eRecommended finger tight; Maximum torque: 0.565 N-m (5 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector (gold-plated brass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Protector\u003c\/td\u003e\n      \u003ctd\u003ePre-installed fluorosilicone material\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the 3300 XL 11 mm proximity probe, adhere to the following industrial engineering practices:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Torque:\u003c\/strong\u003e Do not exceed the maximum rated torque of 63.3 N-m (560 in-lb) for M14 x 1.5 probe cases. The recommended installation torque is 21.1 N-m (187 in-lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 inch) for the FEP-insulated coaxial cable and the stainless steel armor to avoid internal damage to the conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Handling:\u003c\/strong\u003e Connection between the probe and extension cable should be finger-tight. The maximum allowable torque for the ClickLoc coaxial connector is 0.565 N-m (5 in-lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Ensure the fluorosilicone connector protector is fully installed over the coaxial connection to prevent moisture, dirt, and oil contamination. Do not use silicone tape inside the machinery casing or in areas exposed to turbine oil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Setting:\u003c\/strong\u003e Set the initial physical gap between the probe tip and the target to 2.5 mm (100 mils), which corresponds to the midpoint of the 4.0 mm (160 mils) linear range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is certified under the Option 05 Multiple Approvals package for use in hazardous areas. Verified certifications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T5...T1 Ga for intrinsically safe installations in Zone 0; Ex nA IIC T5...T1 Gc and Ex ec IIC T5...T1 Gc for Zone 2 installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCNRTLUs:\u003c\/strong\u003e Class I, Zone 0, AEx\/Ex ia IIC T5...T1 Ga; Class I, Div 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III. Class I, Zone 2, AEx\/Ex nA IIC T5...T1 Gc; Class I, Div 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL Compatibility:\u003c\/strong\u003e SIL 2 certified (HFT = 0) or SIL 3 certified (HFT = 1) when implemented as part of a complete safety instrumented system (SIS) with compliant Bently Nevada monitors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e RoHS compliant and tested to IEC 68-2-3 for damp heat resistance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528498027,"sku":"330704-00-50-10-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330704-00-50-10-01-05-11mm-sensor-vpsygjuumcc_3819ce21-d777-4282-8af0-ea8758c789f5.jpg?v=1765440315"},{"product_id":"bently-nevada-330103-02-17-05-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-02-17-05-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330103-02-17-05-02-05\u003c\/strong\u003e specifies this 3300 XL 8 mm proximity probe configuration, featuring an M10 x 1 metric thread, 20 mm of unthreaded body length (Option 02), and an overall case length of 170 mm (Option 17). This unarmored probe is manufactured with a 0.5-meter total cable length (Option 05), a miniature coaxial ClickLoc connector on standard triaxial cable (Option 02), and carries CSA, ATEX, and IECEx agency approvals for hazardous areas (Option 05).\u003c\/p\u003e\n\u003cp\u003eThis proximity probe is used for non-contact shaft vibration and axial position measurements in critical industrial machinery. The M10 x 1 threaded body provides metric mounting compatibility, while the 170 mm overall case length provides the extended reach necessary for deep-recessed mounting locations. The system operates on the eddy-current principle, delivering output voltage directly proportional to the gap distance when paired with a matching 3300 XL Proximitor sensor and standard extension cable.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM10 x 1 metric threaded body constructed from AISI 303 or 304 stainless steel without armor.\u003c\/li\u003e\n  \u003cli\u003eOption 02 unthreaded length of 20 mm prevents thread binding in standard recessed mounting brackets.\u003c\/li\u003e\n  \u003cli\u003eOption 17 overall case length of 170 mm allows extended physical reach into machine casings.\u003c\/li\u003e\n  \u003cli\u003eOption 05 total probe length of 0.5 meters (1.6 feet) connects directly to local junction boxes.\u003c\/li\u003e\n  \u003cli\u003eOption 02 miniature coaxial ClickLoc gold-plated connector provides low-resistance signal coupling.\u003c\/li\u003e\n  \u003cli\u003eOption 05 CSA, ATEX, and IECEx approvals allow deployment in certified hazardous locations.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) probe tip material withstands chemical exposure and high temperatures.\u003c\/li\u003e\n  \u003cli\u003eTipLoc molding process creates a molecular bond between the probe tip and the stainless steel body.\u003c\/li\u003e\n  \u003cli\u003eCableLoc design provides up to 330 N (75 lbf) of pull strength between the cable and the probe housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration monitoring on high-speed fluid-film bearing machines such as steam turbines and centrifugal compressors.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position and casing expansion tracking in rotating machinery protection systems.\u003c\/li\u003e\n  \u003cli\u003eKeyphasor reference signals and speed measurement applications.\u003c\/li\u003e\n  \u003cli\u003eMachinery diagnostics and predictive maintenance in chemical processing plants, refineries, and power generation facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-02-17-05-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe, M10 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e20 mm unthreaded length (order in increments of 10 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e17\u003c\/td\u003e\n      \u003ctd\u003e170 mm overall case length (order in increments of 10 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (1.6 feet) total probe length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard unarmored cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-02-17-05-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1 (without armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal DC Resistance (Rprobe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.45 plus\/minus 0.50 Ohms (from center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial, fluorinated ethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e22.6 N-m (200 in-lbf) rated; 7.5 N-m (66 in-lbf) recommended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Rated Cable Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) probe case to lead; 270 N (60 lbf) at connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring pressure seal between tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25 mm x 150 mm x 150 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.15 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLimit thread engagement length to a maximum of 15 mm to prevent binding or mechanical interference during installation.\u003c\/li\u003e\n  \u003cli\u003eEnsure that the minimum cable bend radius of 25.4 mm (1.0 in) is maintained at all times during routing to prevent cable shield damage.\u003c\/li\u003e\n  \u003cli\u003eTighten the probe case to the recommended torque of 7.5 N-m (66 in-lbf). Do not exceed the maximum limit of 22.6 N-m (200 in-lbf).\u003c\/li\u003e\n  \u003cli\u003eConnectors must be finger-tight only. Do not exceed the maximum connector torque rating of 0.565 N-m (5 in-lbf).\u003c\/li\u003e\n  \u003cli\u003eMaintain a physical distance or utilize isolation brackets if electrical isolation is required between the probe body and machine housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Approved for hazardous areas when used with certified intrinsic barriers or non-incendive circuits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Certified for use in Zone 0, Zone 1, and Zone 2 explosive atmospheres with appropriate barrier devices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Fully compliant with applicable European Union directives for electromagnetic compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528792939,"sku":"330103-02-17-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-02-17-05-02-05-proximity-probes-1mrxwyihxj5_6454c233-f967-42bf-a2ad-7d7b5577a541.jpg?v=1765440316"},{"product_id":"bently-nevada-330101-48-71-20-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-48-71-20-02-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-48-71-20-02-00\u003c\/strong\u003e is an 8 mm proximity probe belonging to the industry-standard \u003cstrong\u003e3300 XL 8 mm Proximity Transducer System\u003c\/strong\u003e. Designed for non-contact vibration and shaft position measurements, this probe operates on the eddy current principle to provide precise displacement feedback. This specific configuration features a 3\/8-24 UNF threaded body without armor, with a 4.8-inch unthreaded length, a 7.1-inch overall case length, and a total cable length of 2.0 meters (6.6 feet) terminated in a miniature coaxial ClickLoc connector with standard cable. It does not require agency approvals, making it an ideal choice for standard industrial environments where certified hazardous area protection is not mandatory.\u003c\/p\u003e\n\u003cp\u003eAs part of the 3300 XL series, this proximity probe offers excellent mechanical and environmental durability. It is fully compatible with 330180 series Proximitor sensors and standard 3300 XL extension cables. When integrated into a complete 3300 XL monitoring chain, it delivers highly accurate and repeatable measurements, ensuring reliable machinery protection for critical assets such as steam and gas turbines, compressors, pumps, and other rotating machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEddy-current technology for reliable non-contact displacement and vibration measurement.\u003c\/li\u003e\n  \u003cli\u003eSpecially configured with a 4.8-inch unthreaded portion and a 7.1-inch total case length.\u003c\/li\u003e\n  \u003cli\u003e2.0 meters (6.6 feet) of standard triaxial FEP-insulated probe cable for reliable signal transmission.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector provides a secure, vibration-resistant connection.\u003c\/li\u003e\n  \u003cli\u003eViton O-ring pressure seal built into the probe tip to prevent leakages through the casing.\u003c\/li\u003e\n  \u003cli\u003eFully compatible with Bently Nevada 3300 XL series Proximitor sensors and extension cables.\u003c\/li\u003e\n  \u003cli\u003eDesigned for permanent mounting on bearing housings, machine casings, or external brackets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe configuration is commonly deployed in various rotating machinery applications to monitor critical mechanical parameters:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft radial vibration measurements on high-speed turbines and compressors.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position and rotor displacement monitoring in pumps and gearboxes.\u003c\/li\u003e\n  \u003cli\u003eEccentricity and phase reference (Keyphasor) tracking.\u003c\/li\u003e\n  \u003cli\u003ePermanent machine protection in heavy-industry sectors including power generation, oil and gas, and chemical processing plants where standard, non-certified components are sufficient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-48-71-20-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e48\u003c\/td\u003e\n      \u003ctd\u003e4.8 inches (122 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e71\u003c\/td\u003e\n      \u003ctd\u003e7.1 inches (180 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e2.0 meters (6.6 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo agency approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003e330101-48-71-20-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Type\u003c\/td\u003e\n      \u003ctd\u003eDisplacement (proximity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Principle\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting from approximately 0.25 mm (10 mils) up to 2.3 mm (90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial fluoroethylene propylene (FEP) insulated cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) maximum rated (probe case to probe lead)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Torque\u003c\/td\u003e\n      \u003ctd\u003e7.5 Nm (66 in-lbf) for case mounting; finger tight for coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF) for operating and storage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in) for standard probe cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo achieve reliable vibration and position monitoring, follow these essential engineering and installation guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap:\u003c\/strong\u003e Ensure the probe is mounted with the appropriate gap setting matching the system calibration (typically gapped at 1.27 mm or -9 Vdc for radial vibration measurements over the linear range).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnthreaded Length Selection:\u003c\/strong\u003e The 4.8-inch unthreaded length of this probe must be chosen correctly to clear mounting bosses or brackets without interfering with internal rotating components.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection \u0026amp; Bend Radius:\u003c\/strong\u003e Maintain a minimum cable bend radius of 25.4 mm (1.0 in). Route cables through conduits or protective trays to prevent mechanical damage, keeping them away from high-voltage lines to minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoaxial Connection:\u003c\/strong\u003e Ensure ClickLoc coaxial connectors are joined finger-tight. Avoid using heavy pliers or exceeding the maximum connector torque of 0.565 Nm (5 in-lbf).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Properly ground and shield the entire transducer loop. Shielding should typically be terminated at the monitor end, maintaining isolation at the probe casing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis standard Bently Nevada 330101-48-71-20-02-00 configuration utilizes the -00 approval option and is designed for general purpose, non-hazardous industrial environments. It does not carry explosive atmosphere certifications (such as ATEX, IECEx, or CSA hazardous area approvals), which are designated under option code -05. However, it is manufactured under rigorous ISO 9001 quality management procedures and conforms to Bently Nevada's high mechanical, electrical, and environmental performance standards.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528924011,"sku":"330101-48-71-20-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-48-71-20-02-00-probes-xz2tt3bkr0p_93808766-5d5f-4ca9-9b36-0e5ef11be6fa.jpg?v=1765440319"},{"product_id":"bently-nevada-330101-02-21-10-01-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-02-21-10-01-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003eBently Nevada 330101-02-21-10-01-00\u003c\/strong\u003e is an unarmored \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e engineered for high-precision, non-contact machinery protection and condition monitoring. This specific configuration features a 3\/8-24 UNF thread with a short unthreaded case length of 0.2 inches (option 02) and an overall case length of 2.1 inches (option 21). Fitted with a 1.0 meter standard coaxial cable (option 10) and a miniature coaxial ClickLoc connector with an integrated connector protector (option 01), this sensor does not require agency approvals (option 00) and is optimized for standard industrial vibration chains.\n\nOperating on the eddy-current measurement principle, this probe determines the precise dynamic and static distance between the probe tip and a target conductive shaft. It is part of the 3300 XL 8 mm Transducer System, pairing with a 3300 XL extension cable and a 330180 series Proximitor sensor. Together, this chain generates a highly stable voltage output proportional to shaft vibration and position, feeding critical real-time diagnostic data to Bently Nevada 3500 rack modules or other machinery protection systems.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProximity tip diameter of 8 mm designed for precise non-contact eddy-current displacement measurements.\u003c\/li\u003e\n  \u003cli\u003eIntegrated connector protector (option 01) safeguarding the miniature ClickLoc coaxial connection against oil, moisture, and contaminants.\u003c\/li\u003e\n  \u003cli\u003eUnarmored stainless steel threaded body (3\/8-24 UNF) designed for bearing housing or machine casing mount.\u003c\/li\u003e\n  \u003cli\u003eCompact 0.2 in unthreaded length and 2.1 in case length for tight mechanical clearance installations.\u003c\/li\u003e\n  \u003cli\u003e1.0 meter total cable length (standard coaxial) suited for neat connection to local junction boxes.\u003c\/li\u003e\n  \u003cli\u003eExcellent thermal performance and mechanical durability across harsh industrial rotating environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe \u003cstrong\u003eBently Nevada 330101-02-21-10-01-00\u003c\/strong\u003e probe is ideal for permanent mounting on critical rotating machinery, including:\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial position measurement.\u003c\/li\u003e\n  \u003cli\u003eRotor dynamic displacement monitoring in large compressors and industrial pumps.\u003c\/li\u003e\n  \u003cli\u003eBearing oil film clearance and thickness monitoring.\u003c\/li\u003e\n  \u003cli\u003eRadial vibration, thrust position, and speed sensing on high-speed rotating shafts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e0.2 inches (5 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e21\u003c\/td\u003e\n      \u003ctd\u003e2.1 inches (53 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required (No approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003e330101-02-21-10-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Diameter\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Type\u003c\/td\u003e\n      \u003ctd\u003eDisplacement (proximity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Principle\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e0.2 inches (5 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd\u003e2.1 inches (53 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Length\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003eStandard coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMechanical Protection\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAgency Approvals\u003c\/td\u003e\n      \u003ctd\u003eNo approvals required (Option 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +177 degC (-60 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\nEnsure reliable transducer system performance by adhering to the following engineering guidelines:\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap Calibration:\u003c\/strong\u003e Mount the probe with the correct initial mechanical gap (typically 1.27 mm or 50 mils) to target the midpoint of the Proximitor sensor's calibrated linear voltage range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Integrity:\u003c\/strong\u003e Use care when threading the probe into brackets or casings. Do not exceed recommended tightening torque to prevent thread damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Route the standard unarmored coaxial cable inside rigid or flexible conduit to protect it from mechanical wear, pinching, and high temperatures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Verify that the integrated connector protector is properly seated to insulate the ClickLoc junction from lubricating oil, moisture, and debris.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Properly terminate cable shields at the instrument\/monitor end of the loop only, preventing ground loops that introduce electronic noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529120619,"sku":"330101-02-21-10-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-02-21-10-01-00-proximity-probe-f0bf1dmjmxw_e7b05a45-1859-4c42-bab1-7ba26740bd05.jpg?v=1765440324"},{"product_id":"bently-nevada-330104-00-07-10-02-05-3300-xl-8-mm-proximity-probe-with-armor","title":"Bently Nevada 330104-00-07-10-02-05 3300 XL 8 mm Proximity Probe with Armor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330104-00-07-10-02-05\u003c\/strong\u003e specifies a \u003cstrong\u003e3300 XL 8 mm proximity probe\u003c\/strong\u003e configured with M10 x 1 metric threads, a fully threaded 70 mm case, integrated stainless steel armor, a 1.0-meter overall length, and CSA, ATEX, and IECEx approvals.\u003c\/p\u003e\n\u003cp\u003eThis configuration incorporates an unarmored tip followed by a stainless steel armored cable jacket to withstand harsh industrial wear. The miniature coaxial ClickLoc connector is supplied without a connector protector (Option 02) and connects standard coaxial field wiring to a Proximitor sensor. It operates as part of an eddy-current transducer system to monitor machinery shaft vibration, position, or speed.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM10 x 1 metric thread structure with 0 mm unthreaded length (Option 00) for complete thread engagement.\u003c\/li\u003e\n  \u003cli\u003e70 mm overall case length (Option 07) suitable for shallow-depth machine case installations.\u003c\/li\u003e\n  \u003cli\u003e1.0 meter (3.3 feet) overall system cable length (Option 10) matching 9-meter or 5-meter monitoring system requirements.\u003c\/li\u003e\n  \u003cli\u003eStainless steel armored cable provides mechanical protection against abrasion and physical damage.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector (Option 02) offers tool-free gold-plated click connection.\u003c\/li\u003e\n  \u003cli\u003eAgency approval Option 05 qualifies the probe for ATEX, IECEx, and CSA hazardous location installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used in machinery protection systems to monitor rotating equipment parameters. Common industrial deployments include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration monitoring on steam turbines, gas turbines, and industrial compressors.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position tracking on high-speed pumps and gearboxes.\u003c\/li\u003e\n  \u003cli\u003eKeyphasor and speed measurements on industrial machinery shafts.\u003c\/li\u003e\n  \u003cli\u003eMachinery condition monitoring in petrochemical, power generation, and water treatment plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330104-00-07-10-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe, M10 x 1 thread, with armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e07\u003c\/td\u003e\n      \u003ctd\u003e70 mm case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330104-00-07-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length (Option A)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length (Option B)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e70 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length (Option C)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type (Option D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable (no connector protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals (Option E)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Probe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 ohms +\/- 0.50 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDifferential Pressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDesigned to seal up to 10.3 bar (150 psi) using Viton O-ring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 mm (0.31 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (AISI 4140 steel target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e105 mm x 105 mm x 25 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.15 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the total combined length of the probe and extension cable matches the calibrated length of the Proximitor sensor (typically 5 or 9 meters total).\u003c\/li\u003e\n  \u003cli\u003eEnsure correct probe gap during installation (typically gapped at 1.27 mm or 50 mils for mid-range operation).\u003c\/li\u003e\n  \u003cli\u003eTighten the M10 x 1 threads to the proper installation torque; do not exceed 15 Nm (11 ft-lb) to avoid case damage.\u003c\/li\u003e\n  \u003cli\u003eEnsure the miniature coaxial ClickLoc connectors are connected finger-tight. Avoid using heavy pliers which can damage the gold plating.\u003c\/li\u003e\n  \u003cli\u003eRoute the armored cable away from sharp edges, high-temperature conduits, and high-voltage power sources to minimize electrical noise interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eATEX: Flameproof and intrinsically safe approvals for hazardous zones (with compatible barriers)\u003c\/li\u003e\n  \u003cli\u003eIECEx: International hazardous area certification\u003c\/li\u003e\n  \u003cli\u003eCSA: North American safety approval for Class I, Division 1 and Division 2 locations\u003c\/li\u003e\n  \u003cli\u003eCE: Conformity marking for electromagnetic compatibility\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529186155,"sku":"330104-00-07-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330104-00-07-10-02-05-proximity-probes-bug1ykziezs_443d9687-acdc-4471-91df-1fcd49568ba0.jpg?v=1765440325"},{"product_id":"bently-nevada-330130-075-10-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-10-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 075 (7.5 meters cable length), Option 10 (FluidLoc cable), and Option 05 (CSA, ATEX, and IECEx approvals) specify this 3300 XL standard extension cable configuration — \u003cstrong\u003e330130-075-10-05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis configuration utilizes a 3.94 mm outside diameter FluidLoc triaxial cable to block process liquids and oils from migrating through the internal voids of the cable jacket. It connects a 3300 XL 8 mm proximity probe to a 3300 XL Proximitor sensor, establishing a total system length of 9.0 meters when matched with a 1.5-meter probe. The cable features gold-plated ClickLoc connectors that lock with finger-tight pressure to prevent connection degradation in environments with high mechanical vibration.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFluidLoc cable option to prevent migration of lube oil and other process fluids through the cable interior.\u003c\/li\u003e\n  \u003cli\u003eGold-plated ClickLoc coaxial connectors that secure with hand-tightening and resist vibrational loosening.\u003c\/li\u003e\n  \u003cli\u003e7.5 meters cable length matching standard 9.0-meter transducer system specifications.\u003c\/li\u003e\n  \u003cli\u003eNon-armored triaxial construction with FEP outer jacket offering high chemical resistance.\u003c\/li\u003e\n  \u003cli\u003eAgency approval option 05 certifying compliance with CSA, ATEX, and IECEx standards for hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eUsed in rotating machinery condition monitoring systems across heavy industrial processes including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine shaft vibration and axial position measurement\u003c\/li\u003e\n  \u003cli\u003eGas turbine casing and rotor displacement monitoring\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor radial vibration sensing\u003c\/li\u003e\n  \u003cli\u003eIndustrial gearbox shaft movement tracking\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator shaft vibration monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-075-10-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable, FluidLoc, hazardous area approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e075\u003c\/td\u003e\n      \u003ctd\u003e7.5 meters (24.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Connector Protector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc cable, no connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-075-10-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc triaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.5 meters (24.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutside Diameter (Jacket)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 mm (0.155 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaterial (Jacket)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFluorinated Ethylene Propylene (FEP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated coaxial ClickLoc connectors (one male, one female)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCore Resistance (R_CORE)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.65 ohms +\/- 0.25 ohms (center conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eJacket Resistance (R_JACKET)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.49 ohms +\/- 0.10 ohms (outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 degC (-62 to +350 Fahrenheit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e280 mm x 280 mm x 40 mm (H x W x D) (Coiled physical dimensions)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.26 kg (9.2 oz) (typical, excluding packaging)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eObserve the following installation criteria to ensure correct system performance:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDo not bend the cable tighter than the 25.4 mm minimum bend radius limits to prevent internal core damage.\u003c\/li\u003e\n  \u003cli\u003eTighten coaxial ClickLoc connectors by hand until they click; do not use pliers unless mating with older non-XL connectors.\u003c\/li\u003e\n  \u003cli\u003eEnsure field wiring and cable connections are shielded and isolated from sources of high electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eUse silicone tape or connector protectors if the connection is exposed to heavy external contaminants, although FluidLoc prevents internal migration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330130-075-10-05 cable is certified under the following standards when used with an approved proximity sensor and probe assembly:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA Class I, Division 1, Groups A, B, C, D\u003c\/li\u003e\n  \u003cli\u003eATEX Zone 0\/1 Ex ia IIC T4\/T5 Ga\/Gb\u003c\/li\u003e\n  \u003cli\u003eIECEx Ex ia IIC T4\/T5 Ga\/Gb\u003c\/li\u003e\n  \u003cli\u003eCE Mark compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529251691,"sku":"330130-075-10-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-075-10-05-extension-cable-k0kjwbqanxa_b0609b6e-6ba5-4ecc-8c2c-8a3a4cbb70a4.jpg?v=1765440327"},{"product_id":"bently-nevada-330102-04-45-50-01-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330102-04-45-50-01-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eSteel probe case with 3\/8-24 UNF threads featuring a 0.4 in unthreaded length (Option 04) and a 4.5 in overall case length (Option 45) — \u003cstrong\u003e330102-04-45-50-01-00\u003c\/strong\u003e \u003cstrong\u003eproximity probe\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEquipped with stainless steel armor for robust mechanical protection, this configuration includes a miniature coaxial ClickLoc connector with an integrated connector protector (Option 01). The 5.0-meter total length (Option 50) means the probe connects directly to a 5-meter 3300 XL Proximitor sensor, eliminating the need for a separate extension cable. Operating as an eddy-current system, it provides continuous shaft vibration, axial position, and speed measurements on rotating machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3\/8-24 UNF threaded steel probe case with robust stainless steel armor.\u003c\/li\u003e\n  \u003cli\u003e0.4 in unthreaded length (Option 04) for precise clearance adjustment.\u003c\/li\u003e\n  \u003cli\u003e4.5 in overall case length (Option 45).\u003c\/li\u003e\n  \u003cli\u003e5.0 m total length (Option 50) designed to connect directly to a matching 5-meter Proximitor sensor.\u003c\/li\u003e\n  \u003cli\u003eClickLoc coaxial connector featuring a fluorosilicone connector protector (Option 01) to seal out moisture.\u003c\/li\u003e\n  \u003cli\u003eUnapproved variant (Option 00) for standard non-hazardous industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and position monitoring.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric turbine shaft displacement tracking.\u003c\/li\u003e\n  \u003cli\u003eBoiler feed pump axial position thrust measurements.\u003c\/li\u003e\n  \u003cli\u003eLarge industrial compressor and blower vibration protection.\u003c\/li\u003e\n  \u003cli\u003eGearbox shaft dynamic motion monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330102-04-45-50-01-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, with armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e0.4 in unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45\u003c\/td\u003e\n      \u003ctd\u003e4.5 in overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eAgency approval not required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e330102-04-45-50-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer Type\u003c\/td\u003e\n      \u003ctd\u003eNon-contact eddy-current proximity probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e8.0 mm (0.31 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Thread Size\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e0.4 in (10.2 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd\u003e4.5 in (114.3 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with stainless steel armor and FEP outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Protector\u003c\/td\u003e\n      \u003ctd\u003eIncluded (Fluorosilicone material)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAgency Approval\u003c\/td\u003e\n      \u003ctd\u003eNone (Option 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDifferential Pressure Seal\u003c\/td\u003e\n      \u003ctd\u003eUp to 70 psi (4.8 bar) across probe tip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003e303 Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.60 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e9.5 mm x 9.5 mm x 114.3 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Component\u003c\/th\u003e\n      \u003cth\u003eConnection Type \/ Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Connector\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector with gold-plated brass body\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExtension Interface\u003c\/td\u003e\n      \u003ctd\u003eConnects directly to female ClickLoc connector of a 5-meter Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSecure the probe housing using a 9\/16 inch lock nut (supplied).\u003c\/li\u003e\n  \u003cli\u003eVerify that the unthreaded length is at least 0.8 in less than the overall case length to maintain physical housing stability.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum cable bend radius of 25.4 mm (1.0 in) to prevent damaging the internal coaxial core and outer armor.\u003c\/li\u003e\n  \u003cli\u003eHand-tighten ClickLoc connectors to click feedback. Do not use tools on the gold-plated connectors.\u003c\/li\u003e\n  \u003cli\u003eRun probe cables through dedicated, grounded conduits to avoid electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Compliant\u003c\/li\u003e\n  \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n  \u003cli\u003eManufactured under ISO 9001 certified quality standards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529349995,"sku":"330102-04-45-50-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330102-04-45-50-01-00-high-speed-sensor-monitoring-module-eb1pwa34vxd_78bc51bc-25c2-4c22-a8d5-7ef59edc1257.jpg?v=1765440328"},{"product_id":"bently-nevada-330101-00-72-10-12-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-72-10-12-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-00-72-10-12-05\u003c\/strong\u003e is an eddy-current-based \u003cstrong\u003e3300 XL 8 mm Proximity Probe\u003c\/strong\u003e designed for non-contact shaft vibration and position monitoring in critical rotating machinery. Unlike armored configurations, this variant features a lightweight, flexible, unarmored body with standard 3\/8-24 UNF threads, 0.0 inches of unthreaded length, and a 7.2-inch case length to suit deep-well housing installations. A key distinguishing feature of this configuration is its 1.0-meter (3.3 feet) integrated FluidLoc cable with a miniature coaxial ClickLoc connector. The patented FluidLoc cable utilizes an internal sealing process that blocks lubrication oil and other process liquids from migrating along the cable's interior, providing exceptional protection against leakage out of pressurized machine casings. This probe is equipped with the -05 agency approval option, certifying it under international CSA, ATEX, and IECEx hazardous area safety standards for reliable operation in explosive environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 mm tip diameter proximity probe optimized for accurate, non-contact displacement and dynamic vibration measurement.\u003c\/li\u003e\n  \u003cli\u003eFully threaded 3\/8-24 UNF stainless steel case with 0.0 in unthreaded length and 7.2 in overall case length.\u003c\/li\u003e\n  \u003cli\u003eFluidLoc cable design prevents machinery oil and other liquid media from escaping pressurized housings via the cable's internal core.\u003c\/li\u003e\n  \u003cli\u003eGold-plated miniature ClickLoc coaxial connector provides secure, finger-tight locking without requiring specialized installation tools.\u003c\/li\u003e\n  \u003cli\u003eRobust PPS (polyphenylene sulfide) tip material and AISI 303 stainless steel body withstand harsh industrial conditions.\u003c\/li\u003e\n  \u003cli\u003eBroad temperature operating envelope from -52 degC to +177 degC.\u003c\/li\u003e\n  \u003cli\u003eCertified under major hazardous area standards including ATEX, IECEx, and CSA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-72-10-12-05 probe is primarily deployed in demanding industrial environments where continuous machine protection is crucial:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial displacement monitoring on steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eRotor position and casing expansion tracking in high-pressure compressors, turbo-expanders, and pumps.\u003c\/li\u003e\n  \u003cli\u003eMachinery housings requiring tight oil containment, such as oil-filled turbine bearings or flooded gearboxes.\u003c\/li\u003e\n  \u003cli\u003ePermanent installations in petrochemical plants, refineries, pipelines, and power generation facilities requiring certified intrinsically safe components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-72-10-12-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e72\u003c\/td\u003e\n      \u003ctd\u003e7.2 in (183 mm) case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-72-10-12-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDisplacement (proximity), vibration, speed, and phase reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A threads\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.2 in (183 mm) overall case length, fully threaded (0.0 in unthreaded length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUnarmored (without armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) FluidLoc cable (prevents internal oil migration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector (gold-plated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaterial Construction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS) probe tip; AISI 303 stainless steel probe body\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSealed against differential pressure between tip and case (Viton O-ring design)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure precise performance of the 3300 XL proximity transducer system, follow these general engineering rules:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the mounting thread matches the probe's 3\/8-24 UNF profile and has adequate depth (maximum recommended thread engagement of 0.563 inches in standard mounts).\u003c\/li\u003e\n  \u003cli\u003eSet the target-to-probe gap carefully during installation. Standard calibration uses an AISI 4140 steel target with a standard gap offset corresponding to roughly -10 Vdc (1.27 mm or 50 mils) output at the Proximitor sensor.\u003c\/li\u003e\n  \u003cli\u003eEnsure lock nuts with pre-drilled safety wire holes are secured tightly to prevent loosening under heavy vibration.\u003c\/li\u003e\n  \u003cli\u003eProtect standard ClickLoc coaxial connectors from dirt, grease, and mechanical strain. Avoid bending the FluidLoc cable below its minimum bend radius during installation routing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis product configuration complies with the following industry approvals:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 05):\u003c\/strong\u003e Certified for intrinsically safe and non-incendive environments under CSA, ATEX, and IECEx (e.g., Ex ia IIC T1...T5 Ga, Ex nA IIC T1...T5 Gc).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e Complies with European Union EMC Directive 2014\/30\/EU standards including EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e European Union RoHS Directive 2011\/65\/EU and China RoHS compliance with an EFUP rating of 15 years.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 (HFT = 0) and SIL 3 (HFT = 1) certified for safety instrumented systems.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529382763,"sku":"330101-00-72-10-12-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-72-10-12-05-probe-kr4xc2alh0e_4a3d1182-b13e-40a5-99c0-258ce29d63f3.jpg?v=1765440329"},{"product_id":"bently-nevada-330101-00-80-10-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-80-10-02-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-precision rotating machinery monitoring, the \u003cstrong\u003eBently Nevada 330101-00-80-10-02-00\u003c\/strong\u003e is an eddy-current \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e designed for non-contact shaft vibration and position measurement. This exact configuration is built with a standard 3\/8-24 UNF thread housing and is fully threaded (0.0 inches of unthreaded length), presenting an extended 8.0-inch overall case length. It integrates a 1.0-meter standard coaxial cable without armor, terminated in a miniature ClickLoc connector. Free of hazardous area approvals, this specific variant is optimized for cost-effective installation in general-purpose industrial environments where mechanical armor or connector protectors are not required.\u003c\/p\u003e\n\u003cp\u003eAs a key component of the 3300 XL 8 mm Proximity Transducer System, this probe operates on the eddy-current principle to measure static and dynamic distances between the probe tip and a conductive target, typically an AISI 4140 steel shaft. It pairs seamlessly with a 3300 XL Proximitor sensor and a corresponding extension cable, providing a linear range of 2.0 mm (80 mils) with an incremental scale factor of 7.87 V\/mm (200 mV\/mil). This system delivers highly accurate displacement readings that are essential for machinery protection and predictive maintenance systems, such as the Bently Nevada 3500 series rack.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFully threaded case (0.0 in unthreaded length) and long 8.0 in overall housing, ideal for deep bearing housings.\u003c\/li\u003e\n  \u003cli\u003e1.0 meter (3.3 feet) standard unarmored coaxial cable configuration.\u003c\/li\u003e\n  \u003cli\u003eStandard miniature coaxial ClickLoc connector provides low-profile connection to extension cables.\u003c\/li\u003e\n  \u003cli\u003eHigh-performance eddy-current transducer technology delivers reliable non-contact measurement.\u003c\/li\u003e\n  \u003cli\u003eFull compatibility with Bently Nevada 3300 XL monitoring systems and 3500 rack modules.\u003c\/li\u003e\n  \u003cli\u003eViton O-ring design provides high-resistance sealing against differential pressure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine radial shaft vibration monitoring.\u003c\/li\u003e\n  \u003cli\u003eCompressor, expander, and pump shaft axial position and displacement measurement.\u003c\/li\u003e\n  \u003cli\u003eThrust bearing wear and rotor dynamic tracking in large rotating machinery.\u003c\/li\u003e\n  \u003cli\u003ePermanent machinery protection installations on industrial bearing casings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Code\u003c\/th\u003e\n      \u003cth\u003eThis SKU Value\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Specification (from Datasheet)\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-80-10-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length (fully threaded housing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80\u003c\/td\u003e\n      \u003ctd\u003e8.0 in (203 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) probe total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable (no armor, no connector protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required (general-purpose safe area installation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003e330101-00-80-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Diameter\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Type\u003c\/td\u003e\n      \u003ctd\u003eDisplacement (proximity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Principle\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), from approximately 0.25 mm to 2.25 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStandard Case Thread\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A (without armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Case Length\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd\u003e8.0 in (203 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Cable Length\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature ClickLoc coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF) operating and storage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Probe DC Resistance\u003c\/td\u003e\n      \u003ctd\u003e7.59 ohms +\/- 0.50 ohms (for 1.0 m length, center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring probe tip-to-case pressure seal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal performance and prevent premature failure of the 3300 XL proximity probe during installation, observe the following guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap:\u003c\/strong\u003e Mount the probe with the appropriate mechanical clearance gap (typically calibrated to -9 Vdc, or approximately 1.27 mm \/ 50 mils) corresponding to the target center-line of the linear range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Do not exceed the maximum recommended thread engagement of 0.563 inches for 3\/8-24 threads to prevent binding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Always route the probe and extension cables with proper shielding, grounding, and isolation from high-voltage lines. Use conduits or cable trays to prevent mechanical damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Connectors should be finger-tight only. Do not use tools on the ClickLoc gold connectors to avoid damage to the gold plating and physical structure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529579371,"sku":"330101-00-80-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-80-10-02-00-8-mm-probe-4u5mjqy5nh3_f97d92ee-70bb-4f31-9605-8d278d1e7a0b.jpg?v=1765440335"},{"product_id":"bently-nevada-330104-07-14-05-01-00-3300-xl-8-mm-proximity-probe-with-armor","title":"Bently Nevada 330104-07-14-05-01-00 3300 XL 8 mm Proximity Probe with Armor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 07 (70 mm unthreaded length) and Option 01 (coaxial ClickLoc connector with connector protector, standard cable) specify this metric 3300 XL 8 mm probe configuration — \u003cstrong\u003e330104-07-14-05-01-00\u003c\/strong\u003e. This non-contact eddy-current sensor measures shaft vibration, axial position, and keyphasor reference on rotating machinery.\u003c\/p\u003e\n\n\u003cp\u003eFeaturing a heavy-duty stainless steel armored sheath, this variant provides enhanced mechanical shielding for the coaxial lead. This specific combination of a 140 mm case, 70 mm unthreaded segment, and 0.5-meter cable length matches specific machine housing geometries and integrates with 3300 XL Proximitor sensors and extension cables without requiring hazardous area agency approvals.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eStainless steel armor with FEP outer jacket provides protection from physical impact and chemical exposure.\u003c\/li\u003e\n  \u003cli\u003eOption 07 provides 70 mm of unthreaded length on a 140 mm overall metric case.\u003c\/li\u003e\n  \u003cli\u003eMetric thread configuration with M10 x 1 casing thread matches European and ISO machinery mounting standards.\u003c\/li\u003e\n  \u003cli\u003eOption 01 miniature coaxial ClickLoc connector includes a pre-installed fluorosilicone connector protector.\u003c\/li\u003e\n  \u003cli\u003eCompact 0.5-meter total cable length is suitable for direct connections to nearby junction boxes.\u003c\/li\u003e\n  \u003cli\u003eNo agency approvals (Option 00) for general purpose, non-hazardous area applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and dynamic displacement measurements on steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eAxial rotor position and thrust bearing wear monitoring in high-pressure compressors.\u003c\/li\u003e\n  \u003cli\u003eSpeed and tachometer measurements using keyphasor reference signals on industrial pumps.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection systems within power generation, oil and gas, and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eOption Code Segment\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eThis SKU Value\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e330104-07-14-05-01-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e3300 XL 8 mm probe, M10 x 1 thread, with stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e07\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e70 mm unthreaded segment length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e14\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e140 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e05\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e0.5 meter (1.6 feet) cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eD - Connector and Cable Option\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e01\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eMiniature ClickLoc coaxial connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e00\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eNo agency approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e330104-07-14-05-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eThread Size\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eM10 x 1 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eArmoring\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eFlexible stainless steel armor with FEP outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e70 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e140 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTotal Cable Length\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e0.5 meter (1.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCable Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e75 Ohm coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eMiniature coaxial ClickLoc male connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnector Protector\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003ePre-installed on connector end\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTensile Strength\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e330 N (75 lbf) maximum probe-to-cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRecommended Torque\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e15 N-m (110 in-lb) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eThread Engagement\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e15 mm maximum recommended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e185 mm x 185 mm x 45 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px;\"\u003e0.21 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Do not exceed 15 mm of thread engagement inside the bracket or machine housing to prevent mechanical binding of the M10 x 1 casing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25 mm (1.0 inch) for the armored cable to avoid damage to the coaxial core and steel armor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Care:\u003c\/strong\u003e Clean connection surfaces with a dry, lint-free cloth before joining ClickLoc connectors. Tighten only to finger-tight pressure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Calibration:\u003c\/strong\u003e Establish the static operating gap within the linear range of the transducer system (typically 2.0 mm or 80 mils) using a voltmeter.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the outer shield of the extension cable to the designated instrument ground terminal at the Proximitor sensor housing. Do not ground the probe tip or casing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529677675,"sku":"330104-07-14-05-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330104-07-14-05-01-00-3300-xl-8-mm-proximity-probes-pokx4p0xh0x_9a6b64de-5c3c-4b96-bd8e-d09969d0d414.jpg?v=1765440337"},{"product_id":"bently-nevada-330930-040-01-00-3300-nsv-extension-cable","title":"Bently Nevada 330930-040-01-00 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-040-01-00\u003c\/strong\u003e is a 4.0-meter (13.1 feet) 3300 NSv Extension Cable specified with stainless steel armor and an outer FEP jacket (Option 01), without agency approvals (Option 00).\u003c\/p\u003e\n\u003cp\u003eThis cable interfaces between a 3300 NSv proximity probe and a 3300 XL NSv Proximitor Sensor. The addition of the FEP-jacketed stainless steel armor provides protection against physical wear, mechanical shear, and chemical exposure in demanding industrial environments, distinguishing it from standard unarmored configurations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4.0 meters (13.1 feet) overall cable length configuration (Option 040).\u003c\/li\u003e\n  \u003cli\u003eStainless steel protective armor with protective FEP jacket (Option 01).\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc miniature coaxial connectors provide a secure, twist-locking connection.\u003c\/li\u003e\n  \u003cli\u003eDesigned to match 3300 NSv probe impedance and signal characteristics.\u003c\/li\u003e\n  \u003cli\u003eFEP outer jacket resists oils, chemical solvents, and high humidity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and position monitoring in narrow or restricted spaces.\u003c\/li\u003e\n  \u003cli\u003eSmall-bore turbomachinery and aeroderivative gas turbine installations.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed centrifugal compressors and pumps with limited target geometries.\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery where mechanical armor protection against hot oils and abrasion is necessary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330930-040-01-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable, 4.0 meters, armored with FEP jacket, no approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length Option\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eWith stainless steel armor, with FEP jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-040-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStainless steel armor with outer FEP (Fluorinated Ethylene Propylene) jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature coaxial connectors (male\/female)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected (tested to IEC 68-2-3 damp heat)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.220 ohm\/m (0.067 ohm\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShield Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.066 ohm\/m (0.020 ohm\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTypical Cable Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 g\/m (0.7 oz\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Pull Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) connector-to-cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation of the 3300 NSv extension cable ensures stable signal transmission and mechanical durability. Follow these engineering guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 inch) during routing to prevent internal conductor damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e While this configuration does not include pre-installed connector protectors, it is recommended to use connector protectors or silicone self-fusing tape in wet or oil-exposed environments to prevent signal degradation. Do not use silicone tape inside the machine casing if exposed to turbine oil.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRouting:\u003c\/strong\u003e Route cables away from high-voltage lines, AC motors, and other electromagnetic interference sources. Secure cables with appropriate mounting clips without over-tightening.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque:\u003c\/strong\u003e Connect the probe-to-cable miniature ClickLoc connectors to finger tight, then apply a maximum recommended torque of 0.56 Nm (5 in-lb) using proper tools. Do not use pliers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal Length Verification:\u003c\/strong\u003e Ensure that the combined length of the proximity probe and the extension cable matches the total calibrated length of the 3300 XL NSv Proximitor Sensor (typically 5.0 m or 7.0 m).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529808747,"sku":"330930-040-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-040-01-00-3300-nsv-extension-cable-lugo243go3o_42f9bef1-03c2-4945-aa8b-f0e90a75f752.jpg?v=1765440341"},{"product_id":"bently-nevada-330101-30-60-90-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-30-60-90-02-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-30-60-90-02-00\u003c\/strong\u003e is an unarmored \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e designed for non-contact shaft vibration and position measurement within critical rotating machinery. As a key component of the 3300 XL 8 mm Proximity Transducer System, this specific configuration features a 3\/8-24 UNF threaded case with a 3.0-inch unthreaded length, a 6.0-inch overall case length, a 9.0-meter total cable length, and a miniature coaxial ClickLoc connector, configured without agency approvals.\u003c\/p\u003e\n\u003cp\u003eOperating on the eddy-current principle, this transducer system measures the dynamic and static distance between the probe tip and the observed conductive target, such as a machine shaft. It pairs seamlessly with 3300 XL Proximitor sensors (such as the 330180 series) and standard extension cables to deliver extremely accurate, temperature-stable displacement signals. This configuration is commonly integrated into machinery protection systems (including the Bently Nevada 3500 series) to monitor fluid-film bearing clearance, radial shaft vibration, and axial thrust position in high-speed industrial applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEddy-current sensor design for precise non-contact measurement of shaft displacement and vibration.\u003c\/li\u003e\n  \u003cli\u003eGenerous 9.0-meter total length enables direct connection to a Proximitor sensor without requiring a separate extension cable, simplifying wiring in specific system layouts.\u003c\/li\u003e\n  \u003cli\u003e3.0-inch unthreaded length allows deep insertion into machine casing or bearing housings while leaving a 3.0-inch threaded section for robust mechanical adjustment and locking.\u003c\/li\u003e\n  \u003cli\u003eStandard unarmored cable design provides a lightweight, flexible routing path suitable for installations with protective conduit.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector offers a secure, reliable electrical connection that resists moisture and vibration.\u003c\/li\u003e\n  \u003cli\u003eRobust probe tip constructed from high-durability PPS material to withstand harsh, oil-rich industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is ideal for machinery protection and condition monitoring in heavy-industry sectors such as oil and gas, petrochemicals, power generation, and water treatment. Typical application scenarios include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration monitoring in steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eThrust (axial) position measurements on high-speed compressors and turbochargers.\u003c\/li\u003e\n  \u003cli\u003eRotor displacement and bearing wear tracking in heavy industrial pumps and gearboxes.\u003c\/li\u003e\n  \u003cli\u003eShaft centerline tracking and rotational speed\/keyphaser references.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330101-30-60-90-02-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e30\u003c\/td\u003e\n      \u003ctd\u003e3.0 inches (76 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e60\u003c\/td\u003e\n      \u003ctd\u003e6.0 inches (152 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo agency approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-30-60-90-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNon-contact displacement (proximity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMechanical Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 in (76 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.0 in (152 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Mount the probe with the appropriate physical gap from the target surface (typically 1.27 mm or 50 mils for standard calibration, corresponding to -10 VDC output) before locking it into position.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Avoid sharp bends when routing the unarmored cable. Ensure the cable is supported and run through dedicated protective conduit if exposed to physical hazard or extreme mechanical wear.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Connect the outer shield of the probe cable to the instrument ground inside the Proximitor sensor housing. Avoid multiple ground points to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Clearance:\u003c\/strong\u003e Maintain a minimum radial clearance around the probe tip of at least 3 probe diameters (approximately 24 mm) from any surrounding metal to avoid eddy-current side-loading effects.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocking:\u003c\/strong\u003e Tighten mounting nuts securely to the machinery housing or bracket to prevent drift due to structural vibration. Do not exceed recommended torque limits for 3\/8-24 UNF threads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529874283,"sku":"330101-30-60-90-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-30-60-90-02-00-3300-xl-8-mm-probe-4nqjqeh1yhc_ac158f1d-1974-4167-af6a-026c57745cea.jpg?v=1765440343"},{"product_id":"bently-nevada-330101-00-28-10-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-28-10-02-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-00-28-10-02-00\u003c\/strong\u003e is an unarmored 8 mm \u003cstrong\u003eproximity probe\u003c\/strong\u003e configured with a fully threaded 3\/8-24 UNF housing (0.0 inches unthreaded length), a 2.8-inch case length, and a 1.0-meter (3.3 feet) standard coaxial cable with a miniature ClickLoc connector. Designed for systems that do not require hazardous area approvals, this specific variant provides non-contact vibration and shaft position measurements in industrial machinery. It acts as a critical sensing element within a 3300 XL monitoring chain, pairing seamlessly with a 330180 series Proximitor sensor and a corresponding standard extension cable to deliver highly accurate displacement readings.\u003c\/p\u003e\n\u003cp\u003eThis proximity probe utilizes eddy-current technology to track dynamic displacement, such as radial shaft vibration and axial thrust position. Since it is constructed without protective armor, this variant is ideal for installations where the cable path is adequately protected inside conduits or dry machine casings. Its 1.0-meter cable must be integrated into a 5-meter or 9-meter overall system configuration to maintain precise calibration and minimize interference.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 mm tip diameter proximity probe designed for non-contact eddy-current displacement measurement.\u003c\/li\u003e\n  \u003cli\u003eFully threaded 2.8-inch case length without protective armor, optimal for installations where external mechanical wear is not a primary risk.\u003c\/li\u003e\n  \u003cli\u003eEquipped with a miniature coaxial ClickLoc connector, ensuring a secure, click-verified snap connection.\u003c\/li\u003e\n  \u003cli\u003eStandard cable design suited for typical industrial environments with oil and moisture exposure.\u003c\/li\u003e\n  \u003cli\u003eRobust stainless steel case construction with high-performance PPS tip material.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical applications for this probe include turbine shaft vibration and position monitoring, critical compressor and pump rotor displacement measurements, and general rotating machinery protection within power generation, oil and gas, and chemical processing facilities.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-28-10-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e2.8 in (71 mm) case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-28-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDisplacement (proximity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 ohms +\/- 0.50 ohms (from center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure proper operation of the proximity probe, verify that it is mounted with the correct probe gap (typically adjusted to -9 Vdc or approximately 1.27 mm \/ 50 mils) according to system calibration. Route the probe cable with proper shielding and grounding practices to eliminate noise coupling. Ensure that the thread engagement limits are respected during installation, and finger-tighten the ClickLoc connectors to prevent damage to the gold-plated contacts.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666530398571,"sku":"330101-00-28-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-28-10-02-00-3300-xl-8-mm-probe-tga2eq5xtjp_44b8f8d2-642a-4d92-870f-cd6430aef76d.jpg?v=1765440351"},{"product_id":"bently-nevada-330101-00-75-20-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-75-20-02-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-00-75-20-02-00\u003c\/strong\u003e is a highly precise and robust \u003cstrong\u003e3300 XL 8 mm proximity probe\u003c\/strong\u003e configured with a fully threaded 7.5-inch case, a 2.0-meter total length standard cable, and no unthreaded offset (0.0 in). This unarmored eddy-current sensor is engineered specifically for non-contact machinery protection and condition monitoring, delivering high-resolution displacement measurements in critical industrial rotating equipment. Designed without any unthreaded portion, this variant allows complete thread support through bearing housings or specialized mounting fixtures where case protrusion must be avoided. The standard cable configuration coupled with a ClickLoc miniature coaxial connector provides a stable, electrically quiet connection to extension cables, making it excellent for general-purpose monitoring networks that do not require specialized steel armor or hazardous area agency certification.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFully Threaded Design:\u003c\/strong\u003e The 7.5-inch overall case is entirely threaded (0.0 in unthreaded length) to offer optimal depth adjustability and structural stability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Coaxial Cable:\u003c\/strong\u003e Includes a 2.0-meter (6.6 feet) flexible coaxial cable without external armoring, designed for clean pathways or conduit routing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Connector Technology:\u003c\/strong\u003e Terminated with a high-durability miniature coaxial ClickLoc connector for a secure and corrosion-resistant coupling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Contact Displacement Sensing:\u003c\/strong\u003e Utilizing the eddy-current operating principle, it provides continuous, dynamic measurements of rotor shaft vibration and axial position.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e A polyphenylene sulfide (PPS) tip and stainless steel probe body withstand harsh chemical and oil-film industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine rotor shaft vibration and position tracking\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor thrust bearing position monitoring\u003c\/li\u003e\n  \u003cli\u003eBoiler feed pump shaft displacement and thrust displacement\u003c\/li\u003e\n  \u003cli\u003eGeneral-purpose rotating machinery vibration protection loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-75-20-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (No unthreaded portion, fully threaded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75\u003c\/td\u003e\n      \u003ctd\u003e7.5 in (7.5-inch total threaded case length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e2.0 meters (6.6 feet) overall length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required (No hazardous area approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-75-20-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A (without armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0.0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.5 in (190.5 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 meters (6.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current non-contact measurement\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRadial vibration, axial position, speed, and phase reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjusting Probe Gap:\u003c\/strong\u003e Calculate and lock the physical gap positioning using standard calibration voltage responses before securing locknuts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Isolation:\u003c\/strong\u003e Route standard unarmored cables through dedicated electrical conduits or protective trays to safeguard them from mechanical wear or impact.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Maintain proper noise immunity by keeping the coaxial cable shield continuous and grounding it at a single point, typically at the Proximitor sensor housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimizing Crosstalk:\u003c\/strong\u003e Ensure the probe maintains adequate clearance from neighboring metallic surfaces to prevent side-view eddy-current distortions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666530529643,"sku":"330101-00-75-20-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-75-20-02-00-3300-xl-8-mm-proximity-probes-x1ffknjbwsv_dddec6d3-5427-4f3e-a1ec-d2f903523491.jpg?v=1765440353"}],"url":"https:\/\/www.plcprotech.com\/bg\/collections\/machinery-monitoring.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}