{"title":"PLC \u0026 PAC Systems","description":"\u003cp\u003ePLC and PAC systems are industrial controllers used to execute deterministic logic, motion sequences, and process coordination across machines and lines. Architecturally, they combine a CPU, power supply, chassis or backplane, I\/O modules, and field communications that connect sensors, actuators, drives, and HMIs. Typical technical characteristics include scan-cycle execution, rugged operating ratings, onboard diagnostics, non-volatile memory, modular expansion, and support for industrial Ethernet and serial protocols. Functional capability includes discrete control, interlocking, sequencing, PID where applicable, recipe handling, alarms, and integration to supervisory systems. For operator visualization and panel computing, see \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/hmi-industrial-computing\"\u003eHMI \u0026amp; Industrial Computing\u003c\/a\u003e, and for network infrastructure and protocol connectivity, see \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/communication-networking\"\u003eCommunication \u0026amp; Networking\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"allen-bradley-1756-it6i2-controllogix-enhanced-thermocouple-analog-input-module","title":"Allen-Bradley 1756-IT6I2 ControlLogix Enhanced Thermocouple Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-367\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-367\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-367\"\u003e1756-IT6I2 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-367\"\u003eis a heavy-duty ControlLogix 6 Pt Enhanced Thermocouple Analog Input Module engineered for high-accuracy temperature processing in volatile industrial sectors such as petrochemical refining, power generation, and chemical processing \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-367 citation-end-367\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-366\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。As an engineered enhanced thermocouple module, it features six individually isolated channels that provide excellent signal reliability by eliminating ground loops and common-mode electrical hazards \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-366 citation-end-366\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-365\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。This design mitigates unpredicted channel fluctuations, directly maximizing plant uptime and protecting high-value processing loops。The module integrates seamlessly into any standard ControlLogix chassis, serving as a localized or high-performance distributed I\/O station over EtherNet\/IP or ControlNet infrastructures \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-365 citation-end-365\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-364\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThis enhanced module incorporates a high-resolution 16-bit Sigma-Delta analog-to-digital converter to achieve precise microvolt-level quantization over extensive thermal spectrums \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-364 citation-end-364\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-363\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。Its high-performance hardware architecture achieves a common-mode noise rejection of 160 dB minimum when tested under 600V AC at 60 Hz, ensuring signal integrity in environments with extreme electromagnetic interference \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-363 citation-end-363\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-362\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-362\"\u003e。A matched pair of ultra-precision Cold Junction Compensation (CJC) thermistors accompanies the module to achieve a localized stability of \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e\u003cspan class=\"citation-362\"\u003e0.3 deg C across the terminal block interface \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-362 citation-end-362\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-361\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。Linearization is handled onboard via factory-calibrated ITS-90 algorithms \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-361 citation-end-361\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-360\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。When integrated using floating-point data formatting, plant engineers can activate an adjustable digital filter in tandem with the 60 Hz normal-mode notch filter to suppress high-frequency process noise \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-360 citation-end-360\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification (Official Datasheet Verification)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-359\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e1756-IT6I2\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-359 citation-end-359\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-358\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-358 citation-end-358\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-357\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eControlLogix I\/O\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-357 citation-end-357\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-356\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e6 Pt Enhanced TC In Module (Isolated Thermocouple\/Millivolt)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-356 citation-end-356\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-355\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e6 Point Individually Isolated Thermocouple \/ 2 CJC Inputs\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-355 citation-end-355\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Sensors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-354\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThermocouple Types B, C, D, E, J, K, L (TXK\/XK), N, R, S, T\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-354 citation-end-354\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Input Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-353\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e-12 to 78 mV (1.4 microvolts\/bit typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cspan\u003e-12 to 30 mV (0.7 microvolts\/bit high-resolution range)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-353 citation-end-353\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-352\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e16-Bit Sigma-Delta\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-352 citation-end-352\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Input Scan Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-351\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e10 ms min (Integer, millivolt)\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cspan class=\"citation-351\"\u003e25 ms min (Floating Point, millivolt)\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cspan\u003e50 ms min (Floating Point, temperature)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-351 citation-end-351\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-350\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e200 mA @ 5.1 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cspan\u003e120 mA @ 24 VDC\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-350 citation-end-350\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Backplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-349\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e4.6 W\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-349 citation-end-349\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-348\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e4.6 W\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-348 citation-end-348\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-347\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e15.7 BTU\/hour\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-347 citation-end-347\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-346\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e120V AC\/DC maximum\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-346 citation-end-346\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-345\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e160 dB minimum, tested @ 600V AC\/60 Hz with 100 Ohms differential resistance\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-345 citation-end-345\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNormal Mode Rejection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-344\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e60 dB at 60 Hz\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-344 citation-end-344\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Terminal Block\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-343\"\u003e1756-TBNH only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-343\"\u003e (36-pin Removable Terminal Block Housing)\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-343 citation-end-343\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-342\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-342 citation-end-342\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg (0.63 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat is the critical hardware difference between the legacy 1756-IT6I and the enhanced 1756-IT6I2?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-341\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-341\"\u003eThe 1756-IT6I2 provides significantly upgraded common-mode noise rejection (160 dB minimum at 600V AC compared to 120 dB at 60 VAC on the legacy module) and delivers uniform, high-precision local CJC accuracy of \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e\u003cspan class=\"citation-341\"\u003e0.3 deg C across all internal channels \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-341 citation-end-341\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCn I use a 1756-TBSH spring-clamp terminal block with the 1756-IT6I2?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-340\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-340\"\u003eNo. According to the official Allen-Bradley I\/O specifications manual, the 1756-IT6I2 module is strictly compatible with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-340\"\u003e1756-TBNH only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-340\"\u003e (cage-clamp terminal block housing) \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-340 citation-end-340\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-339\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。The spring-clamp variant (1756-TBSH) is not supported for this specific enhanced module \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-339 citation-end-339\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHow does the module signal a field thermocouple sensor failure to the PLC?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-338\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe 1756-IT6I2 features active open-circuit diagnostic logic。If a sensor wire is severed or burnt out, the module detects the open loop and forces a positive full-scale maximum reading within 2 seconds into the controller data table to initiate an immediate emergency process shutoff or alert \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-338 citation-end-338\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering and Commissioning Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-337\"\u003eMandatory CJC Installation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-337\"\u003e The 1756-IT6I2 requires the installation of two matched CJC sensors directly onto the 1756-TBNH terminal block assembly \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-337 citation-end-337\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。Omitting these sensors disables the localized ambient reference tracking, leading to catastrophic temperature calculation drift and inaccurate process values。\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-336\"\u003eShielding Ground Protocols:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-336\"\u003e Implement high-grade, twisted-pair shielded extension cables designated precisely for your specific thermocouple calibration type。Ground the shield drain wire at a single point only—preferably at the heavy copper enclosure ground bus inside the marshalling cabinet。Never run sensitive thermocouple lines through wireways containing high-power AC lines or VFD outputs to prevent inductive cross-talk \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-336 citation-end-336\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-335\"\u003eRemoval and Insertion Under Power (RIUP):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-335\"\u003e This module is fully rated to support RIUP execution while the ControlLogix chassis backplane remains energized \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-335 citation-end-335\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e。However, in hazardous operational classifications, do not attempt to disconnect the 1756-TBNH terminal block or unseat the module unless field power has been entirely isolated and verified as de-energized。\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695172219243,"sku":"1756-IT6I2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-it6i2-controllogix-analog-input-module-qwegkcsp2xd_4df2632e-b084-4ee0-aa1e-d1a97c22a004.jpg?v=1766114079"},{"product_id":"allen-bradley-1756-ow16i-controllogix-16-point-digital-relay-module","title":"Allen-Bradley 1756-OW16I ControlLogix 16 Point Digital Relay Module","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OW16I\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eoperates as a high-integrity, single-slot digital contact output assembly designed for the Allen-Bradley ControlLogix architecture. Engineered specifically for complex process interlocks in thermal power plants, oil refining tank farms, and heavy mining infrastructure, this module provides sixteen independent, Form A normally open relay contact channels. Each output circuit features complete galvanic isolation from adjacent channels and backplane logic, allowing distinct AC and DC field voltages to operate simultaneously on a single module housing. By eliminating common ground reference pathways and suppressing high-voltage transient cross-talk, this module avoids cascaded channel failures, effectively reducing unexpected field instrumentation downtime in high-vibration and electrically noisy industrial processing environments.\u003c\/p\u003e\n\u003ch3\u003eSystem Architecture and Functional Features\u003c\/h3\u003e\n\u003cp\u003eThe hardware topology of this digital relay assembly utilizes sixteen discrete, mechanically robust contact relays configured with basic insulation barriers rated for continuous 250 V electrical isolation. It provides native scheduling capabilities, enabling synchronization of contact state transitions within 16.7 ms maximum with reference to the Coordinated System Time (CST) matrix of the Logix backplane. The module features independent, software-configurable state management for both Fault Mode and Program Mode, allowing system engineers to predefine individual channel responses—Hold Last State, Forced On, or Forced Off (default)—to preserve safe field conditions during processor disruption. It requires no internal hardware jumpers, relying instead on electronic software keying via the integrated development environment to prevent erroneous module cross-insertion during field maintenance.\u003c\/p\u003e\n\u003ch3\u003eEngineering Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Metric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVerified Technical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-OW16I\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix Digital I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay Contacts (16 Form A Normally Open, Individually Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 125 VDC \/ 10 to 240 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw from Backplane\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mA @ 5.1 VDC and 150 mA @ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Backplane Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.4 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 W @ 60 deg C (140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation Loading\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.35 BTU\/hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Contact Ratings (DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 A @ 5-30 VDC, 0.5 A @ 48 VDC, 0.22 A @ 125 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Contact Ratings (AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 A @ 120 VAC, 0.75 A @ 240 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePilot Duty Classifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC300, R150\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Contact Load Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInitial Contact Resistance (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mOhm @ 6 VDC, 1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOff-State Leakage Current (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 mA per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Switching Delays\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOff to On: 10 ms max \/ On to Off: 10 ms max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Switching Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 operation per 3 seconds (0.3 Hz at rated load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage Stability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 V continuous (basic insulation type), outputs-to-backplane and output-to-output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Removable Terminal Blocks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-TBCH, 1756-TBNH, 1756-TBSH, 1756-TBS6H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShock Tolerance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperating: 30 G \/ Non-operating: 50 G\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 G @ 10 to 500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNorth American Temp Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eT4A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg (0.66 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard single-slot ControlLogix module envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 10 mA minimum load current specification on the 1756-OW16I?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe electromagnetic contacts require a minimum wetting current of 10 mA to reliably pierce thin film oxidation layers that naturally develop on the contact surfaces over time. Operating below this current threshold can result in erratic signal continuity or false open-circuit indications despite the relay coil being energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1756-OW16I contain internal fused protection to isolate shorted field loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module is not internally fused. To protect the relay contact pathways from overcurrent damage due to field faults, external fusing must be applied. Utilizing a fused Interface Module (IFM) matching publication 1492-TD008 is recommended, though agency certifications are restricted to direct connections via standard ControlLogix Removable Terminal Blocks (RTBs).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the maximum switching frequency limited to 0.3 Hz at rated load?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the 1756-OW16I relies on mechanical contacts rather than solid-state triacs or transistors, excessive cycle speeds induce thermal stresses and arc degradation. Restricting the cycle rate to 1 operation per 3 seconds prevents contact overheating and ensures the expected contact lifespan of 300 kHz for resistive loads and 100 kHz for inductive loads.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Safety Declarations\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArc Mitigation for Inductive Loads:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen controlling inductive field elements such as motor starter coils or high-capacity solenoids, external surge suppressors must be installed directly across the load terminals. Use an appropriate RC snubber circuit for AC loops and a freewheeling diode for DC loops. Unsuppressed inductive counter-electromotive force (back-EMF) will accelerate contact degradation, resulting in contact welding and catastrophic module damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Assembly Selection and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField conductor hookups must be handled using official 36-pin or 20-pin RTBs (e.g., 1756-TBCH, 1756-TBNH). Separate all high-voltage AC current lines from low-voltage DC logic wires by routing them through independent wire ways within the marshalling panel. Ensure the chassis frame maintains a low-impedance connection to the central plant earth ground plane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLive Maintenance Warning (RIUP Restrictions):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the underlying ControlLogix architecture allows Removal and Insertion Under Power (RIUP) during operational maintenance, executing this process in hazardous locations (Class I Division 2, Temp Code T4A) is dangerous. Field-side supply circuits must be completely isolated and checked for zero voltage before detaching the mechanical terminal blocks or pulling the module from the chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695172284779,"sku":"Allen Bradley 1756-OW16I","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-ow16i-controllogix-16do-isolated-relay-module-5cybh5hxcys_028c8623-e0aa-48df-8386-62d2fb3f4c66.jpg?v=1766114081"},{"product_id":"allen-bradley-1756-l63xt-controllogix-extreme-environment-processor-module","title":"Allen-Bradley 1756-L63XT ControlLogix Extreme Environment Processor Module","description":"\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L63XT (1756-L63XT)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a ruggedized ControlLogix controller engineered explicitly for execution in extreme temperature and high-vibration atmospheres. Functioning across harsh continuous-process field environments including oil and gas extraction fields, desert-based power substations, and heavy surface mining sites, this high-performance processing unit delivers un-compromised automation control where standard PLC hardware fails. Featuring 8 MB of user execution memory and 478 KB of dedicated I\/O memory storage, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L63XT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eimplements an optimized conformal coating to isolate internal electronics from atmospheric humidity and airborne chemical contaminants. Deploying this extreme environment controller prevents critical data corruption, withstands severe thermal cycling without clock degradation, and provides a bumpless redundancy platform on ControlNet layers to minimize catastrophic plant shutdowns and optimize remote system uptime.\u003c\/p\u003e\n\u003ch3\u003eHardware Infrastructure and Network Capability\u003c\/h3\u003e\n\u003cp\u003eThe underlying architectural framework of the 1756-L63XT processor emphasizes wide network integration, multitasking logic execution, and strict physical isolation.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTasking Execution Profile:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 32 independent controller tasks, allowing a maximum of 100 industrial programs per individual task group. This configuration handles complex asynchronous event triggers alongside time-critical loop routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBroad Interface Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunicates seamlessly over industrial networks via native rack-mounted adapters, including EtherNet\/IP, ControlNet, DeviceNet, Remote I\/O, SynchLink, and Data Highway Plus (DH+).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-In Point-to-Point Serial Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncorporates a 1-port RS-232 serial communication path executing DF1 full\/half-duplex channels, DF1 radio modem parameters, master ASCII text streams, and Modbus protocol translation via localized controller logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant System Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrates cross-loading redundancy engines that support synchronized partner tracking over a single ControlNet network link, ensuring seamless main-to-backup processor transfer without loss of process state variable data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetailed Engineering Values\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-L63XT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExtreme Environment (XT) Processor Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (US)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.57 kg (1.25 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Megabytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDedicated I\/O Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e478 Kilobytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Total I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128,000 Total (128,000 Digital \/ 4,000 Analog)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Circuit Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 V Continuous (Tested at 720 V DC for 60 s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw at 5.1 V DC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1200 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw at 24 V DC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Power Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Energy Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.9 BTU per hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAtmospheric Operating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 70 deg C (-13 to 158 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNon-Operating Storage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C (-40 to 185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperational Mechanical Vibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 g acceleration at 10 to 500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Operating Shock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 g mechanical pulse impact\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Non-Operating Shock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 g mechanical pulse impact\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication and Field Engineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the surrounding temperature rating decrease when using specific chassis types?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1756-L63XT is independently rated for up to 70 deg C surrounding air. However, when mounted inside a 1756-A7LXT extreme environment chassis, the system thermal restriction limits the assembly to -25 to 60 deg C. Conversely, when integrated within a paired FLEX I\/O-XT field distribution layout, the bottom thermal tolerance drops safely down to -20 to 70 deg C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific nonvolatile memory cards can be utilized for non-erasable backup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is strictly limited to commercial-grade industrial CompactFlash cards. It supports either the 64 megabyte card model 1784-CF64 or the high-capacity 128 megabyte card model 1784-CF128. Standard commercial off-the-shelf non-Rockwell flash cards must not be deployed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit maintain data integrity during a complete loss of chassis backplane power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1756-L63XT utilizes an integrated energy storage module or a replaceable industrial lithium battery pack. This power backup supplies continuous trickle currents to the SRAM block, preserving active variable tables, internal time clocks, and system status markers until system line voltages recover.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Rigid Safety Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Thermal Clearances and Airflow:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the 1756-L63XT in a sealed extreme-environment NEMA enclosure, ensure proper vertical spacing above and below the 1756-A4LXT, 1756-A5XT, or 1756-A7XT chassis. Maintain at least 50.8 mm (2.0 inches) of un-obstructed air clearance around the outer enclosure housing to guarantee passive natural convection cooling across the processor faceplate at high ambient operating peaks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrostatic Discharge Protection protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnboard processing chips and surface-mount electronic networks are highly susceptible to sudden ESD arcs. Maintenance engineers must engage a grounded ESD wristband bonded directly to the metal enclosure frame prior to sliding the controller out of its chassis slot or manipulating the front stop\/reset pushbutton interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Port Shielding and Noise Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll custom RS-232 serial links utilizing the integrated channel must implement dedicated shielded cabling. Terminate the overall cable shield braid to the metal D-shell casing on the controller end. Do not route the serial lines in close proximity to high-current motor drive cables or inductive power lines to avoid signal interference on ASCII or DF1 networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Mechanical Seating and Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlign the upper and lower circuit card edges with the designated plastic chassis guide tracks. Press the module back smoothly until the rear connectors seat securely into the active backplane bus. Tighten the top and bottom latching screws to a torque spec of 0.6 Nm (5.3 in-lbs) to avoid contact loss under high floor vibrations up to 2 g.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695172481387,"sku":"1756-L63XT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-l63xt-controllogix-xt-logix5563-processor-r3r2aiaarlk_fa2e9179-62e1-42cf-a1e9-cf3cb43a3222.jpg?v=1766114090"},{"product_id":"allen-bradley-1756-pb75-controllogix-24-vdc-controllogix-power-supply","title":"Allen-Bradley 1756-PB75 ControlLogix 24 VDC ControlLogix Power Supply","description":"\u003ch3\u003eProduct Summary\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-PB75\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty chassis power supply within the Allen-Bradley ControlLogix platform, engineered to convert 24 VDC nominal source electricity into regulated backplane voltages. Designed for critical infrastructure deployment in oil and gas extraction, automated manufacturing, and heavy infrastructure substations, this module delivers stable current to local processing racks. By securing a high current capacity across all three operational backplane rails, it prevents voltage sags and module resets, directly reducing unplanned system downtime. The unit mounts directly to the left side of any standard 1756 ControlLogix chassis, integrating into the physical architecture without occupying standard I\/O slots.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the 1756-PB75 utilizes advanced switch-mode power conversion to provide exceptional thermal and electrical efficiency across its entire load spectrum. It distributes a combined maximum power output of 75 W at 60 deg C, managing current allocation across the 1.2 V, 3.3 V, and 24 VDC backplane paths. Equipped with robust overcurrent, short-circuit, and overvoltage protection networks, the power supply automatically isolates internal faults to safeguard the multi-million dollar processor and communications architecture connected to the backplane. The input stage features an engineered line filter to suppress industrial electromagnetic interference (EMI) and ride through transient voltage drops. Status indication is handled via a prominent front-panel LED that gives real-time health readouts of the source input and internal conversion metrics.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-PB75\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix Chassis Power Supplies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 to 32 VDC (24 VDC nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Output Power (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 W @ 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Output Current (1.2 VDC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Output Current (3.3 VDC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Output Current (5.1 VDC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Output Current (24 VDC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.8 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 V continuous (reinforced insulation type), input-to-backplane tested at 2500 VDC for 60 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOvercurrent Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal fuse (non-replaceable) and electronic current limiting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductor Strip Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm (0.31 inches)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecommended Wire Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 mm sq (14 AWG) solid or stranded copper wire rated at 90 deg C minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140 x 112 x 145 mm (5.51 x 4.41 x 5.71 inches)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.95 kg (2.10 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes the front-panel LED on the 1756-PB75 to remain unlit or turn off completely?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlit LED indicates either a total loss of input source voltage (below 18 VDC), an open internal protection fuse due to a severe hardware fault, or an overcurrent condition on the backplane causing the power supply to enter a protective shutdown cycle. Disconnect the supply from the chassis to isolate backplane short circuits during troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1756-PB75 be wired in parallel with another power supply for redundancy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The standard 1756-PB75 does not support parallel operation or load-sharing configurations on a standard chassis. For redundant power architectures, you must utilize the specific redundant power supplies (such as the 1756-PB75R) paired with a 1756-CPR2 redundancy cable and appropriate chassis adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the internal fuse of the 1756-PB75 field-replaceable after an overvoltage event?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The internal input fuse is a factory-sealed component designed as a secondary safety measure. If the fuse blows, it signifies major internal component breakdown, and the entire power supply unit must be sent to an authorized depot for repair or replaced completely.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation and Commissioning Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Fastening and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSlide the 1756-PB75 onto the left side of the ControlLogix chassis until the guide pins engage fully. Tighten the mounting screws securely to the chassis frame. Ensure the chassis grounding lug is bonded to the main enclosure ground bus using a low-impedance copper strap to provide adequate shielding against high-frequency line noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Wiring Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the 24 VDC supply lines using 2.5 mm sq (14 AWG) copper conductors. Ensure the positive wire is secured to the \"+\", the negative wire to the \"-\", and the equipment ground wire to the designated ground terminal on the terminal strip. Keep input power cables separate from signal-level I\/O wiring to mitigate inductive cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain minimum clearances around the power supply as specified by the enclosure design documents (typically 51 mm or 2.0 inches at the top and bottom). Do not obstruct the ventilation slots on the top or bottom of the module housing, as inadequate airflow will cause thermal degradation and premature component fatigue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695172612459,"sku":"1756-PB75","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-pb75-controllogix-standard-power-supply-320tnnyiu4t_e2baecfc-8c45-41b0-8437-7d6ebc6bccd8.jpg?v=1766114095"},{"product_id":"allen-bradley-1756-ox8i-controllogix-digital-i-o-module","title":"Allen-Bradley 1756-OX8I ControlLogix Digital I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-OX8I\u003c\/strong\u003e module provides eight isolated digital output contacts designed for integration within ControlLogix systems. This device supports both AC and DC voltage ranges, enabling control across diverse industrial applications. The 1756-OX8I features individually isolated output groups, ensuring safe and reliable operation in complex electrical environments. Engineered for seamless compatibility with ControlLogix backplanes, the module facilitates straightforward installation and maintenance in automation architectures. This module is ideal for applications requiring robust contact outputs, such as relay-based actuation, status indication, and small motor control. Its isolated design minimizes ground loops and enhances noise immunity, making it suitable for demanding industrial settings.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eProvides 8 N.O. (Normally Open) relay contacts.\u003c\/li\u003e\n\u003cli\u003eIndividually isolated output groups (two points per group) to minimize electrical interference.\u003c\/li\u003e\n\u003cli\u003eOperates with a wide voltage range: AC (10...240V) or DC (5...125V).\u003c\/li\u003e\n\u003cli\u003eHigh pilot duty rating (C300\/R150) for reliable switching.\u003c\/li\u003e\n\u003cli\u003eIncludes status indicators for fault mode and scheduled outputs.\u003c\/li\u003e\n\u003cli\u003eSoftware-configurable electronic keying to prevent improper module installation.\u003c\/li\u003e\n\u003cli\u003eOpen-style enclosure design for efficient heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eControlling external relays, solenoids, and contactors.\u003c\/li\u003e\n\u003cli\u003eProviding status outputs for process instrumentation.\u003c\/li\u003e\n\u003cli\u003eDriving indicator lights or audible alarms.\u003c\/li\u003e\n\u003cli\u003eInterfacing with non-PLC controlled machinery in hybrid systems.\u003c\/li\u003e\n\u003cli\u003eSmall-scale motor start\/stop control in isolated circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 N.O. (Normally Open), individually isolated (two points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC300\/R150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...125V DC10...240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A @ 5...30V DC0.5 A @ 48V DC0.22 A @ 125V DC1.5 A @ 250V AC 50\/60 Hz0.75 A @ 480V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Delay Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOff to On: 13 ms maxOn to Off: 13 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e@ 5.1V: 800 mA@ 24V: 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Backplane Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation, max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.1 W @ 60 degC (140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.57 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-state Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitial Contact Resistance, max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mOhm @ 6V 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Frequency, max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 operation\/3 s (0.3 Hz at rated load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBounce Time, mean\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Contact Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300,000 cycles resistive100,000 cycles inductive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScheduled Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSynchronization within 167.6 ms, reference to the Coordinated System Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStates in Fault mode per point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHold last state, On or Off (Off is default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStates in Program mode per point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHold last state, On or Off (Off is default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Keying\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic, software configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot protected. A fused IF6H is recommended to help protect outputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Terminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-TBCH1756-TBS6H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTB Keying\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser-defined mechanical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ep(1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNorth American temperature code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cblockquote\u003e\n\u003cp\u003e(1) Use this conductor category information for planning conductor routing as described in the system-level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature, operating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 degC (32...140 degF)IEC 60068-2-1 (Test Ab. Operating Cold)IEC 60068-2-2 (Test Bb. Operating Dry Heat)IEC 60068-2-14 (Test Nb. Operating Thermal Shock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature, nonoperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC (-40...+185 degF)IEC 60068-2-1 (Test Ab. Unpackaged Nonoperating Cold)IEC 60068-2-2 (Test Bb. Unpackaged Nonoperating Dry Heat)IEC 60068-2-14 (Test Na. Unpackaged Nonoperating Thermal Shock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensingIEC 60068-2-30 (Test Db. Unpackaged Damp Heat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 g @ 30...500 HzIEC 60068-2-6 (Test Fc. Operating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock, operating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 gIEC 60068-2-27 (Test Ea. Unpackaged Shock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock, nonoperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 gIEC 60068-2-27 (Test Ea. Unpackaged Shock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESD Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV contact discharges8 kV air dischargesIEC 61000-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiated RF Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V\/m with 1kHz sine wave 80% AM from 80...2000 MHz10V\/m with 200 Hz 50% Pulse 100% AM @ 800 MHz10V\/m with 200 Hz 50% Pulse 100% AM @ 880 MHz30V\/m with 1kHz sine wave 80% AM from 2000...2700 MHzIEC 61000-4-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEFT\/Burst Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+-4 kV at 5 kHz on signal portsIEC 61000-4-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Transient Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+-1 kV line-line (DM) and +-2 kV line-earth (CM) on signal portsIEC 61000-4-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConducted RF Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHzIEC 61000-4-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification(1)\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed Industrial Control Equipment, certified for US and Canada. See UL File E48599.UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for US and Canada. See UL File E49480.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Union 2014\/30\/EU EMC Directive, compliant with:• EN 61326-1: Electrical Equipment for Measurement, Control and Laboratory Use. Industrial Requirements• EN 61000-6-2: Industrial Immunity• EN 61000-6-4: Industrial Emissions• EN 61508-2: Programmable Controllers (Clause 8.2 Zone A \u0026amp; B)• EN 61508-2: Programmable Controllers (Clause II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean 2014\/35\/EU LVD, compliant with EN 61010-2: Programmable ControllersAustralian Radiocommunications Law, compliant with EN 61000-6-4: Industrial Emissions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKorean Registration of Broadcasting and Communications Equipment, compliant with Article 58-2 of Radio Waves Act, Clause 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUKCA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIn conformity with the following UK Statutory Instruments and their amendments:• 2016 No. 1091: Electromagnetic Compatibility Regulations• 2016 No. 1101: Electrical Equipment (Safety) Regulations• 2016 No. 107: Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations• 2012 No. 3032: Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMorocco\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArrêté ministériel n° 04-15 du 1er muharram 1437 (15 octobre 2015)Dispositions d'application relatives à la protection des équipements contre les influences de tensionArrêté ministériel n° 04-15 du 29 ramadan 1436 (16 juillet 2015)Compatibilité électromagnétique des équipements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cblockquote\u003e\n\u003cp\u003e(1) When product is marketed. See the Product Certification link at \u0026lt;a href=\"#\"\u0026gt;ra.rockwellautomation.com\u0026lt;\/a\u0026gt; for Declarations of Conformity, Certificates and other certification details.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector \/ Terminal\u003c\/th\u003e\n\u003cth\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e• \u003cstrong\u003eL1-0 to L1-7\u003c\/strong\u003e: Isolated AC\/DC supply commons (Cut to Length)• \u003cstrong\u003eDC-2 (H)\u003c\/strong\u003e: Isolated DC supply common (Cut to Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e• \u003cstrong\u003eOUT-0 N.O. to OUT-7 N.O.\u003c\/strong\u003e: Individually isolated Form A (Normally Open) relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e• \u003cstrong\u003eJumper Bar\u003c\/strong\u003e: For daisy chaining L1 supply to adjacent RTBs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003ci\u003eNote: Connections are made via the removable 36-pin terminal block (1756-TBCH or 1756-TBS6H).\u003c\/i\u003e\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL RISK ASSESSMENT:\u003c\/strong\u003e ARC FLASH HAZARD AND EXPLOSION POTENTIAL. Do not disconnect mechanical wiring links or slide the Removable Terminal Block (RTB) off the locking connectors while active line voltages feed the contact termination blocks. High-potential energy fields present at relay output pins can arc, destroying the module or triggering localized power interruptions.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Align the plastic card-guides of the module with the top and bottom channels of the target slot in the 1756 ControlLogix chassis bank.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eSeating Mechanism:\u003c\/strong\u003e Slide the assembly firmly inward until the structural locking tabs click securely into place, bonding the dual-connector core to the active backplane interface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eField Wire Termination:\u003c\/strong\u003e Strip your field cables to length, land the isolated AC\/DC power lines onto the specific 36-pin RTB terminal blocks, and torque down the compression terminal screws to standard limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eSurge Suppression:\u003c\/strong\u003e Install external surge suppression devices (such as varistors or snubbers) directly across inductive field loads to shield the internal mechanical relay contacts from high-voltage inductive kickback spikes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e5\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eRTB Mating:\u003c\/strong\u003e Push the pre-wired 1756-TBCH or 1756-TBSH block directly over the interface pins, snap the locking latch down, and thread the central retaining fasteners tightly to secure the field interface.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695172677995,"sku":"1756-OX8I","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-ox8i-isolated-contact-module-xirxw3mjtin_11a2dd27-c449-4465-b3dc-73953d8a42ac.jpg?v=1766114098"},{"product_id":"allen-bradley-1771-ib-1771-8-point-digital-input-module","title":"Allen-Bradley 1771-IB 1771 8 Point Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1771-IB\u003c\/strong\u003e is a discrete hardware component operating within the \u003cstrong\u003e1771\u003c\/strong\u003e platform to interface field status inputs with a centralized processor. This device reads dual-state signals from external electrical paths, managing a density of up to 8 channels over an operating input range of 10-27V DC. This input module is fully compatible with standard 2-wire and 3-wire automation components including DC proximity switches, photoelectric sensors, pushbuttons, limit switches, float switches, and selector switches. To ensure signal clarity under harsh environments, it incorporates built-in filtering mechanisms that limit electrical fluctuations before they reach the controller logic.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated input filtering logic circuit to mitigate voltage transients caused by contact bounce and radiated electrical noise.\u003c\/li\u003e\n\u003cli\u003eNative backend connectivity matching standard 1771 I\/O chassis backplane lines for power distribution.\u003c\/li\u003e\n\u003cli\u003eFull structural operational compatibility across both two-wire and three-wire control path field devices.\u003c\/li\u003e\n\u003cli\u003eShipped in specialized protective static-shielded packaging to minimize standard handling damage from electrostatic discharge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfacing discrete industrial machinery status loops with main automation units.\u003c\/li\u003e\n\u003cli\u003eIndustrial sensor network synchronization using proximity or photoelectric arrays.\u003c\/li\u003e\n\u003cli\u003eMachine tool tracking and safety interlocking layouts using pushbuttons and limit switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance and Electrical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1771-IB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662468205474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMexico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDC (12-24V) Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e10-27V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Requirement\u003c\/td\u003e\n\u003ctd\u003e74mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e3mA (for 3-wire devices)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Filter Delay (Turn-On)\u003c\/td\u003e\n\u003ctd\u003e12 + 7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Filter Delay (Turn-Off)\u003c\/td\u003e\n\u003ctd\u003e20 + 7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower down the chassis layout before executing any attachment or disassembly of modular hardware components.\u003c\/li\u003e\n\u003cli\u003eCarefully align the device along the plastic chassis card guides during initial slot placement.\u003c\/li\u003e\n\u003cli\u003eSum the total current draws of all combined cards to ensure the aggregate loop does not exceed the rated output capacity of the backplane power supply.\u003c\/li\u003e\n\u003cli\u003eKeep the component sealed inside its static-shielded bag until immediately before physical insertion to avoid electrostatic discharge damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the off-state leakage current profile from any integrated 3-wire sensing hardware remains below 3mA.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695172940139,"sku":"1771-IB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1771-ib-digital-input-module-mgg10fyvtie_bd155a3c-4278-4789-a2e4-10ce406533ea.jpg?v=1766114110"},{"product_id":"allen-bradley-1756-dhrio-controllogix-data-highway-plus-rio-communication-module","title":"Allen-Bradley 1756-DHRIO ControlLogix Data Highway Plus\/RIO Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-794\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-794\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-794\"\u003e1756-DHRIO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-794\"\u003e functions as a high-integrity, dual-channel communication bridge within the Allen-Bradley ControlLogix architecture\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-794 citation-end-794\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-793\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eEngineered specifically to protect capital investments in legacy plant infrastructure across industries like petroleum refining, continuous automotive assembly, and municipal water treatment, this module provides native physical-layer translation between modern ControlLogix networks and legacy industrial links\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-793 citation-end-793\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-792\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eBy facilitating real-time data migration and interface routing without the high costs of rewiring existing distributed racks, the module dramatically reduces project commissioning risks and avoids catastrophic facility downtime\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-792 citation-end-792\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-791\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe internal processing hardware of the 1756-DHRIO incorporates two isolated communication channels (Channel A and Channel B) that operate independently from one another\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-791 citation-end-791\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-790\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eEach channel can be configured via physical switches or software parameters to run as either a Data Highway Plus (DH+) network interface or a Universal Remote I\/O (RIO) scanner\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-790 citation-end-790\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-789\"\u003eData Highway Plus (DH+) Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-789\"\u003e The module acts as a smart routing gateway that handles token rotation, peer-to-peer messaging, and global data shares between legacy SLC 500 or PLC-5 controllers and standard ControlLogix processors\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-789 citation-end-789\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-788\"\u003eUniversal Remote I\/O (RIO) Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-788\"\u003e The module executes remote network scanning tasks, transmitting discrete I\/O states and managing block transfer data up to 64 words per transaction with legacy distributed devices, including 1771-ASB chassis, 1794 FLEX I\/O adapters, and PanelView operator terminals\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-788 citation-end-788\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-787\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe processing engine natively encapsulates legacy PCCC (Programmable Controller Communication Commands) within the modern Control and Information Protocol (CIP) framework, allowing explicit, multi-hop message routing through up to four independent communication networks and three separate chassis layers\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-787 citation-end-787\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Metric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Product Specification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-DHRIO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Platform\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-786\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eControlLogix (Bulletin 1756)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-786 citation-end-786\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-785\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eDH+ \/ Universal Remote I\/O Interface\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-785 citation-end-785\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannels Available\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-784\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e2 isolated ports, independently configurable\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-784 citation-end-784\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate Options (DH+\/RIO)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-783\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e57.6 kbps, 115.2 kbps, 230.4 kbps\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-783 citation-end-783\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Physical Node Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-782\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e32 physical devices per RIO scanner channel\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-782 citation-end-782\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Logical Rack Address\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-781\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e32 full or partial racks scanned per RIO channel\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-781 citation-end-781\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBlock Transfer Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-780\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eUp to 64 data words per read\/write message\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-780 citation-end-780\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw @ 5.1V DC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e850 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw @ 24V DC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.7 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.3 W @ 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation Loading\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14.67 BTU\/hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Isolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 V continuous (Functional insulation type, channels-to-system\/channel-to-channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Physical Media\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-779\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e1770-CD (Belden 9463) \"Blue Hose\" shielded twisted-pair\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-779 citation-end-779\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOnboard Diagnostic Readout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-778\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eFront-panel 4-character alphanumeric scrolling display\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-778 citation-end-778\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal Programming Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-777\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eIntegrated 8-pin mini-DIN programming terminal connector\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-777 citation-end-777\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlot Width Occupancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 standard ControlLogix chassis slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Envelope\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C (-40 to 185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity Boundaries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95 percent non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat is the purpose of the 4-character alphanumeric display on the front panel of the 1756-DHRIO?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-776\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe integrated alphanumeric status display delivers instantaneous real-time network diagnostics and error reporting directly on the module enclosure\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-776 citation-end-776\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-775\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eDuring normal runtime, it scrolls through configured channel network types, baud rates, and station node addresses\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-775 citation-end-775\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. If a system or media error occurs, it flashes precise fault signatures to help engineers pinpoint duplicate node faults or wiring disruptions without needing an active computer connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCan Channel A operate on DH+ while Channel B simultaneously scans a Universal RIO network?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-774\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-774 citation-end-774\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-773\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eChannel A and Channel B feature separate physical and electronic isolation boundaries\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-773 citation-end-773\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-772\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eYou can configure one channel to handle peer-to-peer supervisor messaging over a DH+ token-ring network while assigning the other channel to act as an active RIO scanner controlling legacy distributed I\/O racks\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-772 citation-end-772\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAre external termination resistors required for the 1756-DHRIO network plugs?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-771\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eYes, proper electrical termination is required at both physical ends of each DH+ or Universal RIO network line to prevent signal reflection errors\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-771 citation-end-771\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-770\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eDepending on the specific network hardware layout and communication speed, you must connect either an 82 Ohm or a 150 Ohm termination resistor across the data lines at the furthest physical end-nodes\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-770 citation-end-770\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Maintenance Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-769\"\u003eTrunk Line Shielding and Grounding Protocol:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-769\"\u003e Use high-grade 1770-CD (Belden 9463) shielded twisted-pair cable for all network wiring\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-769 citation-end-769\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. The continuous copper shield drain wire must be carried through all intermediary terminal plugs along the daisy chain and bonded to an absolute plant earth ground station at \u003cstrong\u003eone end of the network segment only\u003c\/strong\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-768\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eGrounding the shield at multiple spots will generate ground loops that distort data packets, leading to bad CRC error codes\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-768 citation-end-768\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-767\"\u003eNode Addressing and Network Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-767\"\u003e Set the physical node address switches and channel type selectors on the side panel of the module prior to inserting it into the ControlLogix backplane\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-767 citation-end-767\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-766\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eEnsure that all devices connected to an individual channel are programmed to identical baud rates (57.6k, 115.2k, or 230.4k bps)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-766 citation-end-766\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-765\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eOverlapping rack addresses or node mismatch values will disrupt data polling cycles across the network\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-765 citation-end-765\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-764\"\u003eLive-Insertion (RIUP) Safety Constraints:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-764\"\u003e The 1756-DHRIO hardware is fully certified for Removal and Insertion Under Power (RIUP) within an active ControlLogix chassis\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-764 citation-end-764\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. However, if the control panel is deployed in a hazardous area classification (Class I Division 2 explosive atmospheres), you must completely isolate line power or confirm the area is non-hazardous before extracting the module or disconnecting the network terminal block plugs to prevent electrical arcing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695173005675,"sku":"Allen Bradley 1756-DHRIO","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-dhrio-communication-module-4x2xiijxci1_41df7cac-2016-4efa-802e-9a377488f7ca.jpg?v=1766114112"},{"product_id":"allen-bradley-1769-l36erm-compactlogix-5370-controller","title":"Allen-Bradley 1769-L36ERM CompactLogix 5370 Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1769-L36ERM\u003c\/strong\u003e is a packaged automation controller operating within the \u003cstrong\u003eCompactLogix 5370\u003c\/strong\u003e system architecture. This device provides integrated machine control, motion capabilities, and distributed station processing for small to medium-sized industrial machinery setups. Outfitted with 3 MB of built-in non-volatile user memory, the \u003cstrong\u003e1769-L36ERM\u003c\/strong\u003e runs real-time instruction executions and manages localized or remote logic requirements without demanding oversized control cabinet footprints.\u003c\/p\u003e\n\u003cp\u003eOperating over localized industrial infrastructure, the controller features dual Ethernet\/IP communication ports arranged to support linear and Device Level Ring (DLR) network topologies. The architecture permits simultaneous connection to upstream factory networks and downstream control infrastructure. It handles up to 30 local 1769 Compact I\/O module expansions directly via its backplane bus and provides integrated motion capabilities over EtherNet\/IP supporting up to 16 axes. The system relies on a secure secure digital (SD) card for retentive program storage and incorporates a maintenance-free energy storage solution to eliminate external battery reliance during power cycles.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motion on EtherNet\/IP:\u003c\/strong\u003e Supports up to 16 axes of integrated motion control via standard network architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Port Ethernet Capabilities:\u003c\/strong\u003e Built-in dual ports configured to support Device Level Ring (DLR) and linear network options for enhanced link redundancy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Expansion Capacity:\u003c\/strong\u003e Enables direct interface and power distribution for up to 30 local 1769 Compact I\/O expansion modules across three I\/O banks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery-Free Logic Maintenance:\u003c\/strong\u003e Utilizes internal energy storage structures to write memory contents securely to flash during unexpected power sags.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-axis coordinated packaging lines and continuous sorting operations.\u003c\/li\u003e\n\u003cli\u003eIntegrated assembly machines, material handling lines, and automotive component conveyors.\u003c\/li\u003e\n\u003cli\u003eFood and beverage manufacturing, processing cells, and batch mixing stations.\u003c\/li\u003e\n\u003cli\u003eMulti-bank distributed pump stations and environmental water filtration controls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1769-L36ERM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompactLogix 5370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEtherNet\/IP Nodes (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Motion Axes (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal I\/O Module Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum I\/O Banks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 banks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 EtherNet\/IP (Dual-port RJ45), 1 USB port (programming)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Topologies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDevice Level Ring (DLR), Linear, Star\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Distance Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 modules (slots away from power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Card Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1769-SD1 (1 GB shipped standard), 1769-SD2 (2 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnection and Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 industrial Ethernet communication node interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 industrial Ethernet communication node interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType B peripheral connector for local configuration and programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Positioning:\u003c\/strong\u003e Adhere strictly to the module distance rating. The controller must be positioned within 4 module slots of a compatible 1769 system power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Expansion Restrictions:\u003c\/strong\u003e When expanding the configuration past 8 or 16 modules into Bank 2 or Bank 3, ensure standard 1769 expansion cables and end caps are securely fastened to retain bus continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvective Thermal Clearances:\u003c\/strong\u003e Ensure a minimum clearance of 50 mm (2.0 in.) on all sides of the controller layout inside the enclosure panel to maintain acceptable air cross-flow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection:\u003c\/strong\u003e Confirm that the DIN rail or panel mounting plate is connected to a clean functional earth ground point to minimize radio frequency interference (RFI).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695173136747,"sku":"1769-L36ERM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1769-l36erm-compactlogix-3-mb-motion-controller-qa4t01rgwoy_ce9dbaf2-360b-4bf9-b9e9-4a1aebde817f.jpg?v=1766114118"},{"product_id":"allen-bradley-1769-iq32-compact-i-o-digital-input-module","title":"Allen-Bradley 1769-IQ32 Compact I\/O Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1769-IQ32\u003c\/strong\u003e is a high-density digital input module designed for use within the CompactLogix controller platform and expansion Compact I\/O assemblies. This module provides 32 distinct input channels that interface directly with field devices, converting external control voltages into logic-level data for the system processor. Operating as a \u003cstrong\u003e24V DC Sink\/Source\u003c\/strong\u003e module, the \u003cstrong\u003e1769-IQ32\u003c\/strong\u003e accommodates both sinking and sourcing field configurations, offering extensive flexibility when connecting to proximity switches, push buttons, and limit sensors.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e1769-IQ32\u003c\/strong\u003e features a distinct multi-group architecture, separating the 32 inputs into four isolated groups of eight channels each. This channel-to-channel group isolation protects internal system electronics from external electrical faults or ground loops. It communicates seamlessly across the internal 1769 backplane bus and draws power directly through the bus architecture, eliminating the need for separate internal control power modules. Built with an open-style chassis configuration, it is designed for integration inside industrial enclosures to satisfy ambient climate parameters.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Configuration:\u003c\/strong\u003e Provides 32 digital input channels within a single slot width to optimize enclosure space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Input Circuitry:\u003c\/strong\u003e Supports both sink and source field wiring configurations to match a variety of sensor types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup-to-Group Isolation:\u003c\/strong\u003e Divided into four isolated groups of eight points each to block cross-channel faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Status Indicators:\u003c\/strong\u003e Front-facing LED arrays provide immediate visual verification of individual point logic states and diagnostic conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed I\/O processing in factory automation networks.\u003c\/li\u003e\n\u003cli\u003eHigh-density sensor monitoring for packaging machinery and conveyor systems.\u003c\/li\u003e\n\u003cli\u003eMaterial handling controls and automotive assembly lines.\u003c\/li\u003e\n\u003cli\u003eIntegrated digital logic sensing within water treatment and utility infrastructures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1769-IQ32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 inputs (8 points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC sink\/source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...30V DC @ 30 degC \/ 10...26.4V DC @ 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw @ 5.1V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-State Voltage (Min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-State Current (Min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Voltage (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Current (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Delay (On\/Off)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance (Nominal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2 kOhm @ 24V DC \/ 6.1 kOhm @ 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Dissipation (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Distance Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Mounting:\u003c\/strong\u003e Mount the unit firmly onto a zinc-plated steel DIN rail or directly to a backpanel using retaining screws. Maintain proper module distance ratings relative to the system power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Safety:\u003c\/strong\u003e Guard internal circuitry against electrostatic discharge (ESD) by wearing a grounded wrist strap or touching a safe conductive surface prior to handling the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configurations:\u003c\/strong\u003e Route input cables through the front terminal block, ensuring correct grouping configurations for sink or source field devices. Torque terminal block screws to a maximum of 0.68 N m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation and Clearances:\u003c\/strong\u003e Provide sufficient clearance above and below the module assembly within the enclosure to facilitate adequate convective airflow and thermal regulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecUL\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eMarine\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695173333355,"sku":"1769-IQ32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1769-iq32-compact-i-o-module-vhipmvuvinx_83ba8270-5664-4685-854c-300231f8ef54.jpg?v=1766114122"},{"product_id":"allen-bradley-1771-p5-plc-5-power-supply-module","title":"Allen-Bradley 1771-P5 PLC-5 Power Supply Module","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003e1771-P5\u003c\/b\u003e is a chassis-mounted power supply module engineered within the 1771 product line to deliver regulated DC operating power directly to the backplane of standard industrial control chassis. This hardware component functions by accepting a nominal 24V DC input source and converting it to the clean, stabilized current levels required by processor units and adjacent input\/output instrumentation. The \u003cb data-path-to-node=\"1\" data-index-in-node=\"409\"\u003e1771-P5\u003c\/b\u003e configuration features built-in electrical protection mechanisms alongside clear structural diagnostics to ensure consistent power distribution in highly integrated automation environments.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003eSlotted chassis design that mounts directly into standard 1771 universal I\/O backplanes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003eConfigured with a dedicated front-accessible green LED indicator verifying stable output status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003eBuilt-in dynamic overvoltage protection circuit preventing damage from incoming electrical transients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003eIntegrated fuse architecture positioned internally to safeguard system backplane paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003ePower infrastructure for local and distributed 1771 chassis networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003eRegulated power sourcing for multi-slot logic processing arrays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003eIndustrial automation enclosures utilizing direct 24V DC input feeds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"7\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,0,0\"\u003e\u003cb data-path-to-node=\"7,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,1,0\"\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,0,0\"\u003e\u003cb data-path-to-node=\"7,2,0,0\" data-index-in-node=\"0\"\u003ePart Number \/ Model\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,1,0\"\u003e1771-P5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,0,0\"\u003e\u003cb data-path-to-node=\"7,3,0,0\" data-index-in-node=\"0\"\u003eProduct Line\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,1,0\"\u003e1771 Universal I\/O chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,4,0,0\"\u003e\u003cb data-path-to-node=\"7,4,0,0\" data-index-in-node=\"0\"\u003eModule Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,4,1,0\"\u003ePower Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,5,0,0\"\u003e\u003cb data-path-to-node=\"7,5,0,0\" data-index-in-node=\"0\"\u003eInput Voltage Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,5,1,0\"\u003e20.5 to 30.0V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,6,0,0\"\u003e\u003cb data-path-to-node=\"7,6,0,0\" data-index-in-node=\"0\"\u003eNominal Input Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,6,1,0\"\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,7,0,0\"\u003e\u003cb data-path-to-node=\"7,7,0,0\" data-index-in-node=\"0\"\u003eOutput Current Load\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,7,1,0\"\u003e8.0 Amps at 5.06V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,8,0,0\"\u003e\u003cb data-path-to-node=\"7,8,0,0\" data-index-in-node=\"0\"\u003eBackplane Current Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,8,1,0\"\u003e8.0 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,9,0,0\"\u003e\u003cb data-path-to-node=\"7,9,0,0\" data-index-in-node=\"0\"\u003eOvervoltage Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,9,1,0\"\u003eShuts down at 6.3V DC (nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,10,0,0\"\u003e\u003cb data-path-to-node=\"7,10,0,0\" data-index-in-node=\"0\"\u003eStatus Indicators\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,10,1,0\"\u003eGreen LED (Output Normal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,11,0,0\"\u003e\u003cb data-path-to-node=\"7,11,0,0\" data-index-in-node=\"0\"\u003eInternal Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,11,1,0\"\u003eFused Input Circuitry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eChassis Alignment:\u003c\/b\u003e Secure the power supply module into the leftmost assigned slot position of the 1771 I\/O chassis framework to guarantee correct backplane terminal configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eElectrical Termination:\u003c\/b\u003e Ensure all 24V DC wiring lines are isolated from active power sources before executing connections onto the front terminal strip assembly to eliminate current arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eOvercurrent Maintenance:\u003c\/b\u003e Always verify the replacement fuse specs completely align with factory specifications before restoring active power paths following an electrical overload trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eVentilation Matrix:\u003c\/b\u003e Ensure top and bottom chassis air paths remain unobstructed to handle baseline heat dispersal during full-load power output distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695177298283,"sku":"1771-P5","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1771-p5-24v-dc-power-supply-tukionbk2bl_c70d6f20-0638-4d2d-9f17-3c580a602ae9.jpg?v=1766114156"},{"product_id":"allen-bradley-1769-of4-compactlogix-compact-i-o-analog-output-module","title":"Allen-Bradley 1769-OF4 CompactLogix Compact I\/O Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1769-OF4\u003c\/strong\u003e is a 4-channel single-ended analog output module belonging to the \u003cstrong\u003eCompactLogix Compact I\/O\u003c\/strong\u003e system family. This hardware component translates digital processing variables into precision analog current or voltage signals, permitting direct coordination with field devices such as valve actuators, speed drives, and analog instrumentation panel paths. Operating over normal signaling ranges including 0 to 20 mA, 4 to 20 mA, 0 to 5V DC, 1 to 5V DC, 0 to 10V DC, and plus or minus 10V DC, the module integrates an over-range and under-range clamping architecture that automatically bounds active outputs to specified clamp settings upon value limit violation. Equipped with a system bus communication interface, the controller commands real-time multi-channel data adjustments over an internal backplane loop, complete with a physical diagnostics indicator for real-time fault identification.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncorporates 4 high-accuracy single-ended voltage or current output channels.\u003c\/li\u003e\n\u003cli\u003eProvides high digital resolution matching 15 bits plus sign across unipolar and bipolar operational bounds.\u003c\/li\u003e\n\u003cli\u003eFeatures a built-in over-range and under-range detection system that locks field outputs to precise safety boundaries.\u003c\/li\u003e\n\u003cli\u003eOutfitted with a front-facing Module OK LED indicator mapping power verification and software validation checks.\u003c\/li\u003e\n\u003cli\u003eConfigured with non-volatile operational calibrations removing downstream hardware adjustment criteria.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable speed drive control loops and multi-axis motor velocity configuration.\u003c\/li\u003e\n\u003cli\u003eProportional industrial control valve modulation inside fluid or pneumatic distribution plants.\u003c\/li\u003e\n\u003cli\u003eRemote process manipulation and setpoint tracking paths linked to distributed controller platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1769-OF4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 single-ended (voltage or current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Operating Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...20 mA, 4...20 mA, ±10V DC, 0...10V DC, 0...5V DC, 1...5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Scale Analog Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...21 mA, 3.2...21 mA, ±10.5V DC, -0.5...10.5V DC, -0.5...5.25V DC, 0.5...5.25V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 bits plus sign unipolar and bipolar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Rate (All Channels)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 2.5 ms (Interrupts not enabled), Max 3.8 ms (Interrupts enabled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStep Response to 63%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistive Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent: 0...600 Ohm (includes wire resistance); Voltage: 1 kOhm or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductive Load, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mH (current loads), 1.0 uF (voltage loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5% full scale at 25 Celsius (77 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Current Draw, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mA @ 5V DC; 170 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.86 Total Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Power Supply Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 8 modules away from system power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBelden 8761 (shielded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESD Immunity (IEC1000-4-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV contact, 8 kV air, 4 kV indirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiated Immunity (IEC1000-4-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V\/m, 80...1000 MHz, 80% amplitude modulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst (IEC1000-4-4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV, 5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Immunity (IEC1000-4-5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kV galvanic gun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConducted Immunity (IEC1000-4-6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V, 0.15...80 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 Celsius (32...140 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...85 Celsius (-40...185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m (6561 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...500 Hz, 5 g, 0.030 in. peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g, 11 ms panel mounted (20 g, 11 ms DIN rail mounted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 g panel mounted (30 g DIN rail mounted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (HxWxD), Approx\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 x 35 x 87 mm (4.65 x 1.38 x 3.43 in.); Height with tabs: 138 mm (5.43 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight, Approx\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 g (0.61 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the module is positioned no further than 8 expansion spaces away from the primary system power supply unit.\u003c\/li\u003e\n\u003cli\u003eSecure the housing firmly onto a standard industrial DIN rail structure, or bolt directly onto an internal cabinet panel layout utilizing the built-in retractable mounting tabs.\u003c\/li\u003e\n\u003cli\u003eHook up the field signaling paths using Belden 8761 or an equivalent shielded twisted-pair cable format to optimize signal protection.\u003c\/li\u003e\n\u003cli\u003eKeep terminal loop lengths and wire distributions isolated from heavy alternating current motor distribution tracks to mitigate EMI induction risks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695177625963,"sku":"1769-OF4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1769-of4-compact-i-o-modules-ykdwpmmkwp3_26a82a36-f575-4967-b90c-f0a63c4d2bb0.jpg?v=1766114171"},{"product_id":"allen-bradley-1756-if8-controllogix-8-point-analog-input-module","title":"Allen-Bradley 1756-IF8 ControlLogix 8 Point Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eAllen-Bradley \u003cstrong\u003e1756-IF8\u003c\/strong\u003e is a non-isolated analog input module designed for high-density signal acquisition within the \u003cstrong\u003eControlLogix\u003c\/strong\u003e control system architecture. This module provides a direct interface between the programmable automation controller and field sensing instruments, accepting both voltage and current analog signals across its inputs. Configurable for single-ended, differential, or high-speed differential operation modes, the \u003cstrong\u003e1756-IF8\u003c\/strong\u003e delivers precise signal processing and conversion to support stable control loops in diversified industrial processes.\u003c\/p\u003e\n\u003cp\u003eOperating on a Sigma-Delta conversion principle, the module processes signal inputs with a resolution up to 16 bits, enabling highly accurate digital representation of real-world process variables. Built with channel-level diagnostics, the \u003cstrong\u003e1756-IF8\u003c\/strong\u003e actively detects overrange, underrange, and wire-off fault conditions to maintain system up-time and process protection. It utilizes producer-consumer technology to distribute captured data efficiently across multiple controllers over local or remote backplanes.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Mode Configuration:\u003c\/strong\u003e Supports up to 8 single-ended, 4 differential, or 2 high-speed differential input configurations on a single module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Input Signal Range:\u003c\/strong\u003e Accommodates bipolar voltage options of +\/-10V, 0 to 10V, 0 to 5V, as well as current loops ranging from 0 to 20 mA and 4 to 20 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Conversion:\u003c\/strong\u003e Features 15-bit plus sign resolution for bipolar voltage mode and a full 16-bit resolution for unipolar voltage and current inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Process Alarms:\u003c\/strong\u003e Offers programmable process alarms, rate alarms, and diagnostic error reporting directly to the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Chassis Design:\u003c\/strong\u003e Supports Removal and Insertion Under Power (RIUP), allowing field modules to be replaced without disconnecting chassis backplane power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time monitoring of process transmitters in oil, gas, and chemical manufacturing.\u003c\/li\u003e\n\u003cli\u003eHigh-speed data logging for pressure, flow, and level sensors in water treatment plants.\u003c\/li\u003e\n\u003cli\u003eTemperature transducer and sensor integration via external signal conditioners.\u003c\/li\u003e\n\u003cli\u003eGeneral factory automation systems requiring centralized high-density analog sensing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-IF8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 single-ended, 4 differential, or 2 high-speed differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSigma-Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage: +\/-10V, 0-10V, 0-5V; Current: 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-10.25V: 15 bits plus sign; 0-10.25V \/ 0-5.125V \/ 0-20.5mA: 16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mA at 5.1V DC, 40 mA at 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage mode: 1.73 W; Current mode: 2.33 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Formats\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInteger mode (left justified, 2s complement), IEEE 32-bit floating point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Terminal Blocks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-TBCH, 1756-TBS6H (36 Pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN-x\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive analog input terminal for designated channel x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTN-x\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReturn path terminal for designated channel x (internally tied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ei RTN-x\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent loop return terminal linked to internal 249 Ohm resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Push the module firmly into the slot guides of the local or remote chassis until the top and bottom latches click into place. Installation or removal can be performed while backplane power is applied.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable Terminal Block Wiring:\u003c\/strong\u003e Connect unshielded or shielded signal wires to the 36-pin RTB (1756-TBCH or 1756-TBS6H) before attaching the block to the front of the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Strip a short segment of cable jacket, twist the foil shield and bare drain wire together, and attach the drain line to a proper panel earth ground to reduce external electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Loop Resistors:\u003c\/strong\u003e Ensure current loops are correctly routed through the specified i RTN terminal to pass current through the internal 249 Ohm precision resistor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695177855339,"sku":"1756-IF8","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-if8-i-o-module-sdwovjebxop_659f3055-4049-4687-8597-0d5285133445.jpg?v=1766114183"},{"product_id":"allen-bradley-1771-ow-1771-selectable-contact-output-module","title":"Allen-Bradley 1771-OW 1771 Selectable Contact Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1771-OW\u003c\/strong\u003e is a selectable contact output hardware module designed for integration within a 1771 I\/O chassis. Functioning as a specialized switching unit, the device provides 8 outputs arranged into 4 isolated groups of 2, with each distinct group configured around its own independent common connection. Every individual output pathway is electrically isolated from the internal module logic circuitry, enabling the system to simultaneously drive separate external loads up to a maximum continuous current of 1.0A per output at rated power. Because the hardware does not contain built-in surge limiting circuitry, the \u003cstrong\u003e1771-OW\u003c\/strong\u003e must be utilized for switching resistive loads only, and it is not recommended for inductive or capacitive load setups. Logic control processing and internal relay coil energization paths are fully powered directly through the backplane of the host I\/O chassis enclosure.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndividually selectable output jumper configurations allowing each point to be customized for normally-open (N.O.) or normally-closed (N.C.) operation.\u003c\/li\u003e\n\u003cli\u003eFour isolated circuit groupings containing two output lines per group to support multi-common wiring distribution.\u003c\/li\u003e\n\u003cli\u003eElectrical isolation barriers separating field-side output contact switching loops from local backplane logic components.\u003c\/li\u003e\n\u003cli\u003eFront-mounted diagnostic array consisting of 8 status indicators that illuminate when their corresponding output relay coils are energized.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated switching of resistive control loops in factory production environments.\u003c\/li\u003e\n\u003cli\u003eDry contact interface routing to external input modules or low-current logic devices.\u003c\/li\u003e\n\u003cli\u003eDistributed automation control via multi-group contact isolation setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1771-OW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1771 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable Contact Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs per Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 (4 groups of 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1771 I\/O chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24-138V ac RMS, 24-125V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1A per output (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1A maximum per output (at rated power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edc: 30W per output (resistive), ac (suppressed): 30W per output (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Contact Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edc: 10mA @ 24V, ac: 10mA @ 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperate\/Release Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBounce Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10Hz maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 Watts (max.): 3.3 Watts (min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.6 BTU\/hr (max.): 11.3 BTU\/hr (min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 gauge stranded maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/64 inch insulation maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC (-40 to 185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (without condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Arm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1771-WD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Arm Screw Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-9 inch-pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput 0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Contact Output 0 (Group 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon Return Link for Outputs 0 and 1 (Group 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Contact Output 1 (Group 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Contact Output 2 (Group 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon Return Link for Outputs 2 and 3 (Group 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Contact Output 3 (Group 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Contact Output 4 (Group 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon Return Link for Outputs 4 and 5 (Group 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput 5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Contact Output 5 (Group 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Contact Output 6 (Group 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon Return Link for Outputs 6 and 7 (Group 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput 7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Contact Output 7 (Group 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power Safety:\u003c\/strong\u003e Always remove full power from the 1771 I\/O chassis backplane and the connected wiring arm before removing or installing any I\/O hardware to avoid physical injury or unexpected system operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Protection:\u003c\/strong\u003e Prior to handling the physical circuit board assembly, touch a grounded object to discharge static buildup, and avoid touching the rear backplane connector pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Plastic Keying:\u003c\/strong\u003e Mount plastic keying bands onto the chassis backplane tracking points between positions 6 and 8, and between positions 16 and 18 to lock the chosen slot exclusively for this hardware type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Placement Limits:\u003c\/strong\u003e The module can be installed in any available I\/O chassis slot connector except for the leftmost slot position, which is strictly reserved for adapter or processor modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Configuration Control:\u003c\/strong\u003e To modify factory default normally-open operation, remove the 4 side screws to open the housing covers and manually transition internal jumpers K1, K2, K3, and K4 to their N.C. positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterconnect Cable Length:\u003c\/strong\u003e Restrict total field wiring interconnect runs to a maximum boundary length of 1000 feet (304.8 meters).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Loading Warning:\u003c\/strong\u003e Do not hook up two or more outputs in parallel in an attempt to exceed the continuous 1A power rating, as minor deviations in individual relay response times can cause a single contact to bear the entire load current.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695178772843,"sku":"1771-OW","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1771-ow-selectable-contact-output-module-cobvik3xmnl_dc17db47-761d-4d08-9ae9-47fc0d5f59fe.jpg?v=1766114220"},{"product_id":"allen-bradley-1756-l62s-guardlogix-safety-controller","title":"Allen-Bradley 1756-L62S GuardLogix Safety Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-L62S\u003c\/strong\u003e is a safety controller belonging to the GuardLogix family designed for integrated safety and standard control applications within ControlLogix systems. Featuring 4 MB of standard user memory and 2 MB of safety memory, the \u003cstrong\u003e1756-L62S\u003c\/strong\u003e provides dual-controller architecture capability when paired with a safety partner module to achieve high-integrity functional safety. The unit includes one built-in RS232 local programming port for direct communication, configuration, and diagnostics. It supports up to 100 motion axes for complex motion control tasks across automated industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-memory architecture with 4 MB standard memory and 2 MB safety memory\u003c\/li\u003e\n\u003cli\u003eSupports up to 100 motion axes for integrated motion control\u003c\/li\u003e\n\u003cli\u003eIntegrated RS232 serial port for local programming and communication\u003c\/li\u003e\n\u003cli\u003eUtilizes 1756-BA2 replaceable battery for memory retention\u003c\/li\u003e\n\u003cli\u003eSlot-based installation within standard ControlLogix chassis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachine safety control systems requiring functional safety integration\u003c\/li\u003e\n\u003cli\u003eAutomated assembly lines with integrated motion and safety control\u003c\/li\u003e\n\u003cli\u003eHigh-speed packaging equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial robotics safety cell control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-L62S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGuardLogix Safety Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Programming Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmbedded Network Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotion Axis Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-BA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eDCD (Data Carrier Detect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRXD (Receive Data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eTXD (Transmit Data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDTR (Data Terminal Ready)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eGND (Signal Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eDSR (Data Set Ready)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eRTS (Request to Send)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eCTS (Clear to Send)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eNC (Not Connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Installation:\u003c\/strong\u003e Align the controller with the chassis slot guides and slide it in firmly until the top and bottom latches snap into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Connection:\u003c\/strong\u003e Ensure the 1756-BA2 battery is properly connected to the controller before initial power-up to safeguard user memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the ControlLogix chassis to functional earth ground using low-impedance grounding conductors to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Maintain separation between RS232 communication cables and high-voltage AC or motor power lines to preserve signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695179624811,"sku":"1756-L62S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-l62s-guardlogix-5562s-process-fkdv4ie2rdq_d435ffd8-b5de-4483-a9e2-45a6de3e31c0.jpg?v=1766114254"},{"product_id":"allen-bradley-1756-rmc1-controllogix-redundancy-fiber-cable","title":"Allen-Bradley 1756-RMC1 ControlLogix Redundancy Fiber Cable","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe \u003cstrong\u003eAllen-Bradley 1756-RMC1\u003c\/strong\u003e functions as a dedicated, high-speed physical interface assembly engineered to interconnect synchronization channels across redundant hardware platforms. This 1-meter \u003cstrong\u003eControlLogix redundancy fiber cable\u003c\/strong\u003e establishes direct, low-latency inter-module communication between separate 1756-RM or 1756-RM2 redundancy modules mounted in independent chassis. By facilitating continuous hardware state replication and synchronization signals, the assembly allows the backup controller to shadow the primary processor's control tasks, preventing operational disruption during a master unit switchover event.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDedicated High-Availability Interface\u003c\/strong\u003e: Purpose-built for 1756-RM series modules to maintain uninterrupted data synchronization across high-availability controller pairings.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eOptimized Medium Length\u003c\/strong\u003e: Features a fixed 1-meter physical runtime to minimize optical path attenuation while providing sufficient routing tolerance between adjacent racks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFiber-Optic Core Isolation\u003c\/strong\u003e: Employs optical medium paths to deliver superior noise immunity against electromagnetic and radio frequency interference in harsh industrial plant configurations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRobust Connector Retention\u003c\/strong\u003e: Equipped with heavy-duty termination housings that interlock securely into the redundancy module interface ports to avoid accidental disconnections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eInterconnecting 1756-RM redundancy modules in synchronized dual-chassis Large PLC Systems.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh-availability process backup controls within water treatment, power generation, and automotive assembly lines.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCritical infrastructure control loops requiring seamless master-to-backup processor transitions with zero state loss.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCatalogue Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1756-RMC1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eComponent Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePLC \u0026amp; I\/O Accessory Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Line Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eControlLogix Redundancy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecific Function\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eConnector cable to 1756 Redundancy Modules\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 Meter (1mt)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Medium\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eFiber-Optic Core Assembly\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe 1756-RMC1 assembly is specifically dedicated to the ControlLogix redundancy module ecosystem. It is natively compatible with standard 1756-RM modules and 1756-RM2 high-availability hardware platforms. For installations requiring extended distances between control enclosures or across adjacent cabinets, alternative length variants within the same functional family—such as the 3-meter 1756-RMC3 or 10-meter 1756-RMC10 assemblies—must be used instead of splicing or altering this fiber runtime.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nA major engineering pitfall during deployment involves violating the physical bend radius parameters of the fiber-optic core inside wire duct channels. Forcing sharp 90-degree creases or crimping the cable bundle with overtightened plastic ties induces micro-bending losses, which degrade signal attenuation levels at the transceiver junctions and lead to synchronization dropouts or unrecoverable partner-loss faults. Additionally, ensure both fiber connector ferrule tips are carefully inspected and cleared of dust and grease prior to mating; using fouled interconnect paths can corrupt data validation packets, blocking the primary and backup systems from establishing a qualified synchronized state.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Never look directly into the transceivers of the redundancy modules or the uncoupled ends of the fiber cable terminations while the system is powered. Invisible laser or LED radiation may be present, posing a severe risk of permanent optical or eye tissue damage.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eLocate the primary and secondary 1756-RM redundancy modules seated in their corresponding master and backup ControlLogix chassis.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eRemove the protective clean-room dust caps from the fiber connector ports on both redundancy modules.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eAlign the keying layout of the 1756-RMC1 cable connector with the matching receptor channel on the primary chassis redundancy unit.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eInsert the interface connector firmly until it clicks and locks into place, ensuring the latch mechanism engages completely.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e5\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eRoute the remaining 1-meter span through open wiring ducts, keeping smooth, loose turns, and connect the opposite side to the partner redundancy module.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695180640619,"sku":"1756-RMC1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-rmc1-controllogix-1-m-rm-fiber-optic-cable-zwekayxlvff_3c539e96-3343-4c82-9cae-bdb3488cec7d.jpg?v=1766114273"},{"product_id":"allen-bradley-1756-tbnh-controllogix-removable-terminal-block","title":"Allen-Bradley 1756-TBNH ControlLogix Removable Terminal Block","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe Allen-Bradley \u003cstrong\u003e1756-TBNH\u003c\/strong\u003e is a 20-position NEMA-style screw clamp removable terminal block (RTB) designed to provide dedicated field-side interface connections for ControlLogix I\/O modules. This accessory plugs directly into the front electrical interface of standard 1756 I\/O modules, allowing plant technicians to install, modify, or swap field instrumentation without disconnecting individual signal conductors or disturbing localized panel wire looms. Featuring a robust housing structure rated for high-temperature operational demands, it accommodates multi-conductor combinations of solid or stranded wiring across standard instrumentation gauges.\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003e20-Position Form Factor\u003c\/strong\u003e: Incorporates 20 distinct terminal path channels to handle dense field sensor and actuator distributions.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDual Conductor Support\u003c\/strong\u003e: Each localized termination position accommodates up to 2 independent conductors, enabling efficient signal jumping or parallel circuit routing.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFlexible Wire Composition\u003c\/strong\u003e: Fully compatible with both solid and stranded copper wire frameworks.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Temperature Rating\u003c\/strong\u003e: Designed to safely execute in heavy-duty processing margins with a physical wiring temperature rating of 90 degC or higher.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRemovable Framework\u003c\/strong\u003e: Enables instantaneous mechanical uncoupling from the host module block to simplify control panel servicing and maintenance operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003eField connection sourcing for discrete and analog digital ControlLogix automation modules.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003eMarshalling panel marshalling and signal consolidation inside dense industrial enclosure schemes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003eEnvironments experiencing high machine vibration or thermal cycling requiring stable screw-retained conductor pressure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n\u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e1756-TBNH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eRemovable Terminal Block (RTB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Line\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eUPC\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e612598171859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNumber of Supported Positions\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e20 Positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTermination Style\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eScrew Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWire Types Supported\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eSolid and Stranded Copper Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWiring Temperature Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e90 degC or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWire Size Range\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e22 to 14 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMaximum Conductors per Terminal\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e2 conductors per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eScrew Connection Torque\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e1.36 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eScrewdriver Width Limit\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e8 mm max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModule Compatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e1756 ControlLogix I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e0.25 lbs (0.11 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 1756-TBNH is a heavy-duty 20-position block featuring NEMA-style screw clamps. It cannot directly substitute for standard 36-position modules (such as the 1756-TBCH or 1756-TBSH) due to strict mechanical pitch and footprint variances. When building systems prone to severe continuous mechanical vibration or where swift tooling is preferred, the spring-clamp version 1756-TBS6H should be considered if slot parameters align. Ensure the target I\/O module explicitly references 20-position block tracking in its installation documentation.\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eA major point of systemic failure stems from under-torquing or over-torquing the screw terminals during commissioning phases. Failing to reach the specified 1.36 Nm threshold can generate high-resistance connections or intermittent signal drops under thermal variation, while exceeding it risks stripping the internal threads. Additionally, if the tool blade width exceeds 8 mm, it can crack the plastic protective barriers between the pins, degrading the electrical creepage path. Ensure that all conductors are stripped neatly and fully seated beneath the clamp to prevent loose copper strands from spanning neighboring circuits.\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n\u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Completely isolate and de-energize all primary lines and field-side auxiliary loops prior to assembling or inserting the terminal block mechanism. Interfacing or seating wire bundles while circuits remain energized can provoke localized electric arcs, resulting in data loop disruption, field component damage, or explosion hazards in volatile zones.\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 1rem;\"\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e1\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eExamine the host 1756 module housing interface to ensure all locking tracks and internal mechanical connector paths are clean and uninhibited.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e2\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eStrip conductor ends to the recommended length, ensuring the gauge is safely between 22 and 14 AWG. Use copper wire rated for 90 degC or higher.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e3\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eRoute wire lines through the bottom or side pathways of the enclosure wire duct, leaving sufficient slack to allow the block assembly to separate.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e4\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eInsert wire leads under the screw clamp plates and tighten down the termination assembly to exactly 1.36 Nm using an 8 mm or narrower slotted screwdriver.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e5\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eAlign the wired terminal block with the mating guide pins on the front interface of the matching 1756 I\/O module.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e6\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003ePress the assembly firmly into the front slot until the latching tabs seat flush and click, mechanically locking the electrical path.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695181230443,"sku":"1756-TBNH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-tbnh-screw-terminal-block-jqgzz1r2ygo_337eb655-4b17-46b7-a929-f9ad7ba6418a.jpg?v=1766114295"},{"product_id":"allen-bradley-1768-enbt-compactlogix-ethernet-ip-communication-module","title":"Allen-Bradley 1768-ENBT CompactLogix EtherNet\/IP Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003e1768-ENBT\u003c\/strong\u003e is a \u003cstrong\u003eCompactLogix EtherNet\/IP Communication Module\u003c\/strong\u003e developed by \u003cstrong\u003eAllen-Bradley\u003c\/strong\u003e to provide dedicated Ethernet networking capabilities for 1768 control systems. This module establishes reliable data transmission links across an industrial network, enabling seamless connectivity with multiple Logix5000 controllers, supervisory computers, and auxiliary automation equipment. It processes network traffic over a integrated communication interface while managing local status via an alphanumeric display and built-in diagnostic indicators. Designed as an open-type component, it installs directly within a synchronized hardware stack consisting of a 1768 controller and compatible power supplies to optimize throughput and minimize communication downtime.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides automated data management over EtherNet\/IP networks to reduce packet collisions and sustain optimal bandwidth.\u003c\/li\u003e\n\u003cli\u003eFeatures an integrated alphanumeric display and three bi-color diagnostic status indicators (NET, Link, and OK) for rapid local troubleshooting.\u003c\/li\u003e\n\u003cli\u003eSupports high-speed data transmission over standard Category 5 or Category 5e cabling using a rugged RJ45 connector interface.\u003c\/li\u003e\n\u003cli\u003eImplements reliable electrical protection with a continuous functional insulation rating of 30V between the Ethernet network and internal system circuits.\u003c\/li\u003e\n\u003cli\u003eInterfaces directly with specialized 1768 CompactLogix system components and supports flexible expansion using combined 1769-series I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed industrial automation and manufacturing plant network management.\u003c\/li\u003e\n\u003cli\u003eInter-controller data synchronization across multiple Logix5000 systems.\u003c\/li\u003e\n\u003cli\u003eSCADA network routing and remote control system interface integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e834 mA at 5.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.34 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e30V (continuous-voltage rating), Functional Insulation Type, Ethernet network to system (Type tested at 710V DC for 60 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003eRJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO\/IEC 24702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Category\u003c\/td\u003e\n\u003ctd\u003e2 - on communication ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Temp Code\u003c\/td\u003e\n\u003ctd\u003eT4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC Temp Code\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Screw Torque\u003c\/td\u003e\n\u003ctd\u003e1.16 N.m (10 lb.in) using M4 or #8 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD), Approx.\u003c\/td\u003e\n\u003ctd\u003e132 x 56.7 x 105.1 mm (5.20 x 2.23 x 4.12 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, Approx.\u003c\/td\u003e\n\u003ctd\u003e0.213 kg (7.5 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature, Operating\u003c\/td\u003e\n\u003ctd\u003e0...60 degC (32...140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature, Nonoperating\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC (-40...185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e5 g @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Shock\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions\u003c\/td\u003e\n\u003ctd\u003eCISPR 11 Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type Rating\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 1\u003c\/td\u003e\n\u003ctd\u003eTD+ (Transmit Data +)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 2\u003c\/td\u003e\n\u003ctd\u003eTD- (Transmit Data -)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 3\u003c\/td\u003e\n\u003ctd\u003eRD+ (Receive Data +)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 4\u003c\/td\u003e\n\u003ctd\u003eNC (No Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 5\u003c\/td\u003e\n\u003ctd\u003eNC (No Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 6\u003c\/td\u003e\n\u003ctd\u003eRD- (Receive Data -)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 7\u003c\/td\u003e\n\u003ctd\u003eNC (No Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 8\u003c\/td\u003e\n\u003ctd\u003eNC (No Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePlan for a minimum hardware clearance of 105 mm (4 in.) at the top and bottom, and 90 mm (3.54 in.) on the sides from enclosure walls, wireways, and adjacent machinery.\u003c\/li\u003e\n\u003cli\u003eEnsure the system is grounded through the DIN rail to the chassis ground by utilizing zinc-plated yellow-chromate steel DIN rail; avoid aluminum or plastic rails which can oxidize and cause poor conductivity.\u003c\/li\u003e\n\u003cli\u003eSecure the mounting DIN rail to the surface approximately every 200 mm (7.87 in.) and install appropriate end-anchors to hold modules firmly.\u003c\/li\u003e\n\u003cli\u003eIf choosing panel mounting instead of DIN rail installation, mark pilot holes using the hardware as a template, drill holes for M4 or #8 screws, and tighten to 1.16 N.m (10 lb.in) of torque. Do not use screws and DIN rail concurrently.\u003c\/li\u003e\n\u003cli\u003eConnect the network interface cable to a 100 MB Ethernet switch rather than a shared hub to increase network bandwidth and reduce lost packets.\u003c\/li\u003e\n\u003cli\u003eNever connect or disconnect network communication cables while power is actively applied, as an electrical arc can occur and present an explosion hazard in certified environments.\u003c\/li\u003e\n\u003cli\u003eAlways wait for all diagnostic status lights on the power supply and controller to turn completely off before disconnecting any system module to allow the processor sufficient time to finish writing project parameters to non-volatile memory.\u003c\/li\u003e\n\u003cli\u003eMitigate static risks by touching a grounded object, wearing an approved grounding wriststrap, and strictly avoiding contact with component board pins, connectors, or internal circuit elements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ec-UL-us Listed Industrial Control Equipment, Certified for US and Canada (UL File E65584)\u003c\/li\u003e\n\u003cli\u003ec-UL-us Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations, Certified for US and Canada (UL File E194810)\u003c\/li\u003e\n\u003cli\u003eCE Certified (European Union 2004\/108\/EC EMC Directive, compliant with EN 61326-1, EN 61000-6-2, EN 61000-6-4, and EN 61131-2)\u003c\/li\u003e\n\u003cli\u003eC-Tick Compliant (Australian Radiocommunications Act, compliant with AS\/NZS CISPR 11)\u003c\/li\u003e\n\u003cli\u003eEx Certified (European Union 94\/9\/EC ATEX Directive, compliant with EN 60079-15 and EN 60079-0; II 3 G Ex nA IIC T4)\u003c\/li\u003e\n\u003cli\u003eEtherNet\/IP ODVA Conformance Tested\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695181295979,"sku":"1768-ENBT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1768-enbt-ethernet-communication-module-xn03bzvskda_9fdc6228-c7e0-4e2d-99ef-e63c97bad7a7.jpg?v=1766114297"},{"product_id":"allen-bradley-1756-enbt-controllogix-ethernet-ip-bridge-module","title":"Allen-Bradley 1756-ENBT ControlLogix EtherNet\/IP Bridge Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1756-ENBT\u003c\/strong\u003e is a chassis-based industrial communication module engineered for the \u003cstrong\u003eControlLogix\u003c\/strong\u003e hardware architecture. It functions as a dedicated bridge link between localized automation infrastructure and macro-level plant networks, handling explicit messaging and real-time distributed data transfers over EtherNet\/IP links. Incorporating 1 standard copper RJ45 socket that handles 10\/100 Mbps communication rates over Category 5 network infrastructure, the \u003cstrong\u003e1756-ENBT\u003c\/strong\u003e supports 64 TCP\/IP connections alongside up to 128 simultaneous CIP connections to execute multi-node monitoring and distributed standard remote IO interfaces.\u003c\/p\u003e\n\u003cp\u003eEmploying a standardized open-style enclosure rated to occupy a single slot width inside any standard hardware rack, this communication module uses producer-consumer networking mechanisms to facilitate seamless data distribution across multiple distributed system controllers. Field personnel can perform diagnostic assessments directly via the onboard front digital indicator panel. The circuit framework provides up to 30V continuous operational isolation between the physical network cabling and the backplane logic components to insulate internal automation architectures against transient external electrical surges.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBridges Control Network Architectures:\u003c\/strong\u003e Provides a specialized communication interface linking upstream factory networking layers with standard remote I\/O sub-assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Connection Topologies:\u003c\/strong\u003e Features dual capability with support for a maximum of 64 TCP\/IP connections alongside 128 physical CIP connection configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Hardware Diagnostics:\u003c\/strong\u003e Front-mounted localized digital indicators simplify system verification by reporting live hardware states and communication errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Media Support:\u003c\/strong\u003e Built with a standard 10\/100 Mbps copper RJ45 port compatible with shielded or unshielded category 5 twisted-pair media lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote I\/O station integration and localized distributed control rack telemetry.\u003c\/li\u003e\n\u003cli\u003eStandardized supervisory control and real-time plant data management links.\u003c\/li\u003e\n\u003cli\u003eInter-chassis processor logic sharing and machine-to-machine data synchronization.\u003c\/li\u003e\n\u003cli\u003eVariable frequency drive monitoring and integrated remote peripheral instrumentation data paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-ENBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSub Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Copper RJ45 (10\/100 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections Supported (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCP: 64, CIP: 128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCIP Unconnected Messages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 + 64 (backplane + Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700mA @ 5.1V DC, 3mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.6 btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30V (continuous), basic insulation type, Ethernet network to backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Temp Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Celsius to 60 Celsius (32 Fahrenheit to 140 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to 85 Celsius (-40 Fahrenheit to 185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 G @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Operating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet RJ45 Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory 5 shielded or unshielded twisted pair network connection interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the circuit board edge with the top and bottom channel guides of a free rack slot inside the target chassis. Push firmly inward until the securing mechanism locks completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Media Routing:\u003c\/strong\u003e Secure the 802.3 compliant Category 5 Ethernet cable to the front RJ45 port. Implement appropriate cable management bends to avoid mechanical tension on the port assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Mitigation and Separation:\u003c\/strong\u003e Keep network lines segregated from motor supply leads and high-power AC conductors within the industrial cabinet to mitigate localized electromagnetic induction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Cleanliness:\u003c\/strong\u003e Since the unit utilizes an open-style open-style chassis configuration, maintain ambient surrounding temperatures below 60 Celsius and guard against conductive foreign debris.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eChina CCC\u003c\/li\u003e\n\u003cli\u003eAustralian RCM\u003c\/li\u003e\n\u003cli\u003eAmerican Bureau of Shipping\u003c\/li\u003e\n\u003cli\u003eSemiconductor Inds Immunit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOfficial Product Documentation\u003c\/h3\u003e\n\u003cp\u003eAccess and download the official Allen-Bradley manufacturer publications for this module:\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; min-width: 500px; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; font-size: 14px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color: #f8f9fa; border-bottom: 2px solid #dee2e6; text-align: left;\"\u003e\n        \u003cth style=\"padding: 12px; font-weight: 600; color: #333;\"\u003eDocument Title \/ Type\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; font-weight: 600; color: #333;\"\u003ePublication Number\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; font-weight: 600; color: #333; text-align: right;\"\u003eAction\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #dee2e6;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: 500; color: #212529;\"\u003eControlLogix Communication Modules Technical Data\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #495057;\"\u003e1756-TD003\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; text-align: right;\"\u003e\n          \u003ca href=\"https:\/\/www.plcprotech.com\/cdn\/shop\/files\/1756-td003_-en-e_72b548d8-1701-4bf6-8a4a-d18b11f31b95.pdf?v=1783057783\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: 500;\"\u003eDownload PDF ↗\u003c\/a\u003e\n        \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #dee2e6;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: 500; color: #212529;\"\u003eControlLogix EtherNet\/IP Bridge Module Installation Instructions\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #495057;\"\u003e1756-IN019\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; text-align: right;\"\u003e\n          \u003ca href=\"https:\/\/www.plcprotech.com\/cdn\/shop\/files\/1756-in019_-en-p.pdf?v=1783057844\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: 500;\"\u003eDownload PDF ↗\u003c\/a\u003e\n        \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #dee2e6;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: 500; color: #212529;\"\u003eControlLogix 5580 and 5570 Systems Selection Guide\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #495057;\"\u003e1756-SG001\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; text-align: right;\"\u003e\n          \u003ca href=\"https:\/\/www.plcprotech.com\/cdn\/shop\/files\/1756-sg002_-en-p.pdf?v=1783057951\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: 500;\"\u003eDownload PDF ↗\u003c\/a\u003e\n        \u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #dee2e6;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: 500; color: #212529;\"\u003eControlLogix 5580 Controllers Product Profile\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #495057;\"\u003e--\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; text-align: right;\"\u003e\n          \u003ca href=\"https:\/\/www.plcprotech.com\/cdn\/shop\/files\/1756-pp001_-en-p.pdf?v=1783057950\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: 500;\"\u003eDownload PDF ↗\u003c\/a\u003e\n        \u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695181525355,"sku":"1756-ENBT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-enbt-controllogix-enet-ip-comms-module-nwoad43j5ga_6d111120-4447-4d00-83a0-7aacafdaea06.jpg?v=1766114306"},{"product_id":"allen-bradley-1756-if16-controllogix-analog-input-module","title":"Allen-Bradley 1756-IF16 ControlLogix Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-IF16\u003c\/strong\u003e is a ControlLogix non-isolated analog voltage and current input module designed to convert analog field signals into digital data for processing by ControlLogix controllers. It provides 16 single-ended, 8 differential, or 4 high-speed differential input channels with selectable input ranges including +\/-10V, 0...10V, 0...5V, and 0...20 mA. Operating across the ControlLogix backplane using Producer\/Consumer technology, the \u003cstrong\u003e1756-IF16\u003c\/strong\u003e enables efficient input data sharing across multiple controllers on the network without requiring separate polling mechanisms.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 16 single-ended, 8 differential, or 4 high-speed differential input channels\u003c\/li\u003e\n\u003cli\u003eSelectable input ranges: +\/-10V DC, 0...10V DC, 0...5V DC, and 0...20 mA DC\u003c\/li\u003e\n\u003cli\u003eOn-board digital filtering and input scaling to engineering units\u003c\/li\u003e\n\u003cli\u003eReal-time sampling with customizable channel scanning speeds\u003c\/li\u003e\n\u003cli\u003eUnder-range, over-range, and wire-off fault detection per channel\u003c\/li\u003e\n\u003cli\u003eCompatible with 36-pin Removable Terminal Block (RTB) housings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess control monitoring in oil, gas, and chemical facilities\u003c\/li\u003e\n\u003cli\u003eTemperature, pressure, and flow monitoring systems\u003c\/li\u003e\n\u003cli\u003eFactory automation analog signal processing\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment monitoring\u003c\/li\u003e\n\u003cli\u003ePower generation and energy management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-IF16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e16 single-ended, 8 differential, 4 high-speed differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-10V DC, 0...10V DC, 0...5V DC, 0...20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current (5.1V DC)\u003c\/td\u003e\n\u003ctd\u003e150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current (24V DC)\u003c\/td\u003e\n\u003ctd\u003e65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Backplane Power\u003c\/td\u003e\n\u003ctd\u003e2.33 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003eVoltage: 2.3 W \/ Current: 3.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003eVoltage: 7.84 BTU\/hr \/ Current: 11.25 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250V continuous, basic insulation, inputs to backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible RTB\u003c\/td\u003e\n\u003ctd\u003e1756-TBCH, 1756-TBS6H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 1\u003c\/td\u003e\n\u003ctd\u003eGround \/ Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 2\u003c\/td\u003e\n\u003ctd\u003eIN-0 (+) Input Channel 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 4\u003c\/td\u003e\n\u003ctd\u003eIN-0 (-) \/ Return Channel 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 3\u003c\/td\u003e\n\u003ctd\u003eIN-1 (+) Input Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 5\u003c\/td\u003e\n\u003ctd\u003eIN-1 (-) \/ Return Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 6-34\u003c\/td\u003e\n\u003ctd\u003eAlternating Signal (+), Signal (-), and Common Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 35\u003c\/td\u003e\n\u003ctd\u003eCommon \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 36\u003c\/td\u003e\n\u003ctd\u003eGround \/ Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure chassis power is off or verify area non-hazardous status before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eInsert the module into any available slot of a ControlLogix 1756 chassis.\u003c\/li\u003e\n\u003cli\u003eSecure wiring using an approved 36-pin Removable Terminal Block (1756-TBCH or 1756-TBS6H).\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cables for analog signal connections to mitigate EMI\/RFI noise.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields to designated shield grounding points as instructed in system documentation.\u003c\/li\u003e\n\u003cli\u003eProvide adequate chassis clearance to support proper cooling air ventilation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed Industrial Control Equipment\u003c\/li\u003e\n\u003cli\u003eCSA Certified Process Control Equipment\u003c\/li\u003e\n\u003cli\u003eCE Marked for European Directives\u003c\/li\u003e\n\u003cli\u003eRCM Australian Radiocommunications Compliance\u003c\/li\u003e\n\u003cli\u003eKC Korean Class A Electromagnetic Compatibility\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695181558123,"sku":"1756-IF16","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1756-IF16_4.jpg?v=1783586698"},{"product_id":"allen-bradley-1769-ecr-compact-i-o-right-end-cap","title":"Allen-Bradley 1769-ECR Compact I\/O Right End Cap","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1769-ECR\u003c\/strong\u003e is a right end cap and terminator designed for use with the Compact I\/O system topology. As an essential component for system integrity, the \u003cstrong\u003e1769-ECR\u003c\/strong\u003e terminates the internal communication bus of a Compact I\/O expansion bank or controller chassis, such as those utilizing 1769-L32E controllers. Every 1769 Compact I\/O platform requires a functional end cap to secure signal continuity across the backplane bus. The module is engineered as open-type equipment for clean indoor industrial environments and must be mounted within a protective enclosure suited to local environmental hazards.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination:\u003c\/strong\u003e Completes the electrical communication bus path at the rightmost end of a 1769 Compact I\/O assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Backplane Powering:\u003c\/strong\u003e Draws a minimal current of 5 mA directly from the 5.1V DC backplane bus, requiring no external power connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Locking Mechanism:\u003c\/strong\u003e Provides mechanical stability and secure locking to adjacent I\/O modules via integrated sliding latches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Earthing:\u003c\/strong\u003e Achieves structural grounding automatically through direct contact with a properly earthed DIN rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystem bus termination for Allen-Bradley CompactLogix and Compact I\/O architectures.\u003c\/li\u003e\n\u003cli\u003eFactory automation, machine control, and distributed I\/O control systems.\u003c\/li\u003e\n\u003cli\u003eHazardous location installations requiring Class I, Division 2 or Zone 2 safety certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1769-ECR \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight End Cap \/ Terminator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw at 5.1V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw at 24V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC (32 degF to 140 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Surrounding Air Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 degC (140 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNorth American Temp Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT3C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUK\/ATEX\/IECEx Temp Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 mm x 85 mm x 32 mm (4.65 in. x 3.35 in. x 1.26 in.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Mount the module directly on a zinc-plated chromate-passivated steel DIN rail to ensure low electrical resistance and reliable earthing. Avoid aluminum or plastic rails which can corrode or degrade grounding paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Installation:\u003c\/strong\u003e Install inside an enclosure that requires a tool for access, provides a minimum ingress protection rating of IP54 for Zone 2 zones, and satisfies a flame spread rating of 5VA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Protection:\u003c\/strong\u003e Avoid touching the internal connector pins or circuit traces during assembly. Work at a static-safe station or wear a grounded wrist strap when handling the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Attachment:\u003c\/strong\u003e Slide the end cap firmly into the right side of the final I\/O module and secure the communication path using the built-in locking mechanism.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Division 2, Groups A, B, C, D \u003c\/li\u003e\n\u003cli\u003eUKEX (II 3 G Ex ec IIC T4 Gc; Certificate: UL22UKEX2516X) \u003c\/li\u003e\n\u003cli\u003eATEX (II 3 G Ex ec IIC T4 Gc; Certificate: DEMKO 12 ATEX 1116807X) \u003c\/li\u003e\n\u003cli\u003eIECEx (Ex ec IIC T4 Gc; Certificate: IECEx UL 21.0112X) \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695181656427,"sku":"1769-ECR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1769-ecr-right-end-cap-3ljewdcqavl_e7220a67-da45-4862-b5c4-780c1196995e.jpg?v=1766114311"},{"product_id":"allen-bradley-1771-ob-plc-5-digital-dc-output-module","title":"Allen-Bradley 1771-OB PLC-5 Digital DC Output Module","description":"\u003cp\u003eThe \u003cstrong\u003e1771-OB\u003c\/strong\u003e is an 8-channel digital solid-state electronic device engineered for the \u003cstrong\u003ePLC-5 \/ 1771 I\/O Platform\u003c\/strong\u003e to drive low-voltage direct current industrial control hardware. It provides electrical switching paths for various field components, including DC motor drivers, status indicators, and industrial solenoid valves. The internal control micro-logic is energized via the local \u003cstrong\u003eI\/O chassis\u003c\/strong\u003e backplane rail, drawing a maximum current of 165 mA to maintain structural optoelectronic isolation between high-level plant field elements and core processor busses. System integration is established through the standard \u003cstrong\u003e1771-WA\u003c\/strong\u003e wiring arm connector assembly, permitting physical hot-swapping or card replacement sequences without disturbing landed field terminal connections.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Output Distribution\u003c\/strong\u003e: Integrates eight independent solid-state DC switching circuits within a single-slot chassis package.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Short-Circuit Protection\u003c\/strong\u003e: Individual 2 A, 8AG protective fuses mounted per channel safeguard the module against severe field overcurrent hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Status Array\u003c\/strong\u003e: Equipped with nine front-panel diagnostic LEDs providing localized visualization of blown-fuse status and specific channel conduction states.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Input Interlocking\u003c\/strong\u003e: Supports zero-potential ground reference looping to directly drive discrete DC input modules, such as the 1771-IB receiver block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptoelectronic Backplane Protection\u003c\/strong\u003e: Incorporates continuous 1500 Vca (rms) galvanic isolation to prevent destructive external voltage transients from damaging backplane control logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Slot Keying\u003c\/strong\u003e: Backplane socket keying fields restrict module slot alignment, ensuring only matched electrical module types sit within defined wiring nests.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed control of factory floor solenoid-actuated pneumatic manifolds.\u003c\/li\u003e\n\u003cli\u003eDirect activation of low-current DC motor speed control enable drives.\u003c\/li\u003e\n\u003cli\u003eRemote instrumentation control panels and pilot lamp illumination matrix lines.\u003c\/li\u003e\n\u003cli\u003eInter-rack logic interlocking with low-voltage input hardware sub-assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1771-OB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLC-5 \/ 1771 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital DC Output Driver Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs Per Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1771 I\/O Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Operational Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Vdc to 27 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 A per individual output (not to exceed 8 A total per module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Surge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A for 1 ms, repeatable at 1 s intervals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mA maximum per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-State Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Vdc maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Transmission Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms (On to Off and Off to On states)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 Watts minimum, 16.9 Watts maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 BTU\/h minimum, 57.6 BTU\/h maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Logic Current Demand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e165 mA @ 5 Vdc plus\/minus 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptoelectric Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 Vca (rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Ambient Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible cable with 1.5 mm2 nominal cross-section\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Plastic Keying Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween positions 4 and 6, and between positions 18 and 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Fusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A, 8AG rating (one individual fuse per output path)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1771-WA Wiring Arm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Terminal Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+DC Voltage Supply Input Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Channel 0 Signal Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Channel 1 Signal Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Channel 2 Signal Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Channel 3 Signal Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Channel 4 Signal Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Channel 5 Signal Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Channel 6 Signal Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Channel 7 Signal Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Common Ground Return Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal to Bit Discrepancy\u003c\/strong\u003e: The terminal channel designations etched on the physical 1771-WA wiring arm hardware do not directly map to software internal image register data bits. Refer strictly to the system allocation table when building control code.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential Equalization\u003c\/strong\u003e: When cross-linking an output channel directly into an input processing unit (such as a 1771-IB), a common power supply loop must feed both blocks to tie all reference grounds to an identical voltage potential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity Critical Warning\u003c\/strong\u003e: Correct structural polarity must be maintained on all direct current power terminals. Applying alternating current (AC) power configurations or cross-wiring polarity rails will result in critical module hardware destruction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power Balancing\u003c\/strong\u003e: The 165 mA backplane current consumption must be calculated into the aggregate power supply capacity budget of the specific 1771 chassis rack to avoid thermal overloading or backplane dip errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Grounding Procedures\u003c\/strong\u003e: Operators must latch an approved ESD wrist grounding strap to a structural physical ground point or discharge local potentials by touching an earth-grounded steel frame before touching card edges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlastic Keying Installation\u003c\/strong\u003e: Ensure the chassis backplane keying pegs are properly seated at the factory positions (between pins 4\/6 and pins 18\/20) to prevent the accidental insertion of mismatched voltage cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis De-energization\u003c\/strong\u003e: Complete chassis rack power downcycles are required prior to sliding the driver module out of its physical slot to protect operators and prevent inductive backplane transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Extraction Protocol\u003c\/strong\u003e: To safely swap a compromised fuse assembly, release the front mechanical swing arm latch, withdraw the board housing, undo the two case retention screws, and replace the spent 2 A, 8AG component inside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What specific fuse replacement specification must be used if a channel drops out?\u003c\/strong\u003e A: Each individual output switch is paired with a standard 2 A, 8AG form-factor fuse accessible underneath the card side cover.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this DC driver module be safely slotted into the leftmost slot of a 1771 chassis?\u003c\/strong\u003e A: No, the far-left slot of the 1771 chassis configuration is structurally reserved for the master processor module or remote I\/O network adapter head.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module display indicators on the front face for individual circuit diagnostics?\u003c\/strong\u003e A: Yes, it features one dedicated red LED for blown fuse notification alongside eight individual red status LEDs that light up when an output channel is actively energized.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695182606699,"sku":"1771-OB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1771-ob-digital-dc-output-driver-module-3votzyt5u4d_51486138-8d7c-4a78-b921-cc00c9f77c03.jpg?v=1766114346"},{"product_id":"allen-bradley-1756-pa72-controllogix-ac-power-supply","title":"Allen-Bradley 1756-PA72 ControlLogix AC Power Supply","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \u003cstrong\u003eAllen-Bradley 1756-PA72\u003c\/strong\u003e is a standard AC power supply designed to provide regulated backplane power directly to compatible ControlLogix chassis. Operating on a nominal input voltage of 120V or 240V AC at 50\/60 Hz, this module delivers multi-rail DC outputs across the \u003cstrong\u003e24V DC\u003c\/strong\u003e, \u003cstrong\u003e5.1V DC\u003c\/strong\u003e, \u003cstrong\u003e3.3V DC\u003c\/strong\u003e, and \u003cstrong\u003e1.2V DC\u003c\/strong\u003e lines to power processor, I\/O, and communication modules. It features \u003cstrong\u003ereinforced insulation\u003c\/strong\u003e providing continuous 250V isolation between the power input and the backplane, protecting sensitive control circuitry from line-side electrical anomalies. The unit is designed with an open-style enclosure and mounts directly on the left side of the ControlLogix chassis, utilizing internal card guides for precise alignment.\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eAuto-Sensing Input\u003c\/strong\u003e: Automatically detects and adapts to 120V AC or 240V AC input line voltages without manual jumper settings.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eMulti-Output Backplane Support\u003c\/strong\u003e: Supplies simultaneous current capacities of 2.8A at 24V, 10.0A at 5.1V, 4.0A at 3.3V, and 1.5A at 1.2V up to a 100W maximum total power limit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh Isolation Voltage\u003c\/strong\u003e: Features 250V continuous reinforced insulation from the power input to the system backplane.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eVisual Status Diagnostics\u003c\/strong\u003e: Integrated green power indicator LED provides immediate local visual feedback of correct module operation.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eIntegrated Circuit Protection\u003c\/strong\u003e: Accommodates external 15A time-delay fusing on ungrounded lines to protect internal power elements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003eMain chassis power sourcing for industrial factory automation systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003ePowering distributed I\/O chassis in wastewater treatment, chemical processing, and packaging facilities.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003eInfrastructure assembly power for complex machinery using high-density ControlLogix module layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n\u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eAttribute\u003c\/th\u003e\n\u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e1756-PA72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eVoltage and Current Ratings Input\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e120\/240V AC, 50\/60 Hz, 100VA, 100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput (Current Capacity)\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e2.8 A @ 24V DC; 10.0 A @ 5.1V DC; 4.0 A @ 3.3V DC; 1.5 A @ 1.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMaximum Backplane Power Load\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e75W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e20 A inrush max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e250V (continuous), Reinforced Insulation Type, Power Input to Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTemperature, Operating\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e0 degC to +60 degC (+32 degF to +140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTemperature, Surrounding Air, Max\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e60 degC (140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEnclosure Type Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal Block Screw Torque\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e0.565 N-m (5 lb-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eWire Size\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e2.5 mm2 (14 AWG) solid or stranded copper wire rated at 90 degC (194 degF) or greater, 1.2 mm (3\/64 in.) insulation max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNorth American Temperature Code\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eUnited States \/ USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e1.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (HxWxD), approx\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e14.0 x 11.2 x 14.5 cm (5.51 x 4.41 x 5.71 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n\u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal Pin Number\u003c\/th\u003e\n\u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eAC Power Supply Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eL1 (High side of line power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eL2 (Low side of line power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eNot Used (Terminal is capped to prevent use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eProtective Earth. Attach to chassis ground lug or ground bus.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe standard 1756-PA72 functions within identical chassis form-factors as the 1756-PA75 power supply, though it presents distinct total output current limits (75W maximum output versus 75W backplane limits with variance across specific rails). For systems running under extended temperature profiles or requiring conformal coatings, standard units do not substitute for the K-suffix (e.g., 1756-PA72K) or XT series variations (e.g., 1756-PA30XT) which support operating spectrums from -25 degC to +70 degC.\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eA common field risk involves failure to remove the temporary protective label from the top vents of the power supply housing prior to commissioning. This label must remain intact exclusively during panel fabrication to block airborne metallic shavings from entering the module circuitry. Operating the module with the label attached blocks passive air convection, forcing thermal buildup beyond the maximum 60 degC surrounding air limit and triggering premature electrical stress or module shutdown. Additionally, users must avoid wire daisy-chaining on single terminals; use external distribution blocks for multiple line configurations.\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n\u003cstrong\u003eImportant Safety Notice:\u003c\/strong\u003e Remove all incoming power before installing or servicing the power supply. Do not connect or disconnect wiring while power is applied. Verify that all stored electrical energy has been discharged before handling the module.\u003c\/div\u003e\n\u003ch4\u003eInstallation Considerations\u003c\/h4\u003e\n\u003cp\u003eBefore installing the ControlLogix AC Power Supply, verify that the chassis is properly mounted and connected to protective earth ground. Disconnect all incoming power sources and follow applicable lockout\/tagout procedures before performing installation or maintenance work.\u003c\/p\u003e\n\u003ch4\u003eMounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the power supply on the left side of the ControlLogix chassis.\u003c\/li\u003e\n\u003cli\u003eAlign the circuit board with the chassis card guides.\u003c\/li\u003e\n\u003cli\u003eSlide the module fully into position until flush with the chassis front.\u003c\/li\u003e\n\u003cli\u003eSecure the unit using the top and bottom mounting screws.\u003c\/li\u003e\n\u003cli\u003eKeep the protective cover in place until enclosure fabrication is complete.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse 14 AWG (2.5 mm2) copper conductors rated for at least 90 degC.\u003c\/li\u003e\n\u003cli\u003eProtect ungrounded power connections with a 15 A time-delay fuse.\u003c\/li\u003e\n\u003cli\u003eTighten terminal connections to 0.565 N.m (5 lb-in).\u003c\/li\u003e\n\u003cli\u003eConnect only one conductor per terminal.\u003c\/li\u003e\n\u003cli\u003eInput voltage is automatically sensed and does not require manual voltage selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eGrounding and Safety\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVerify proper chassis grounding before energizing the system.\u003c\/li\u003e\n\u003cli\u003eDo not connect or disconnect wiring while power is applied.\u003c\/li\u003e\n\u003cli\u003ePrevent metal shavings, dust, or debris from entering the power supply during installation.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate enclosure ventilation for long-term reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStatus Indicator Check\u003c\/h4\u003e\n\u003cp\u003eThe front-panel green status indicator should remain illuminated during normal operation.\u003c\/p\u003e\n\u003cp\u003eIf the indicator is off:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify incoming line voltage.\u003c\/li\u003e\n\u003cli\u003eCheck backplane loading requirements.\u003c\/li\u003e\n\u003cli\u003eReseat the power supply in the chassis.\u003c\/li\u003e\n\u003cli\u003eReplace the unit if the indicator remains off after troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695182639467,"sku":"1756-PA72","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-pa72-controllogix-ac-power-supply-25dc0el1ja3_f13555e7-52e0-4f1f-a67e-ac9d6be4615f.jpg?v=1766114347"},{"product_id":"allen-bradley-1768-l43-compactlogix-processor-module","title":"Allen-Bradley 1768-L43 CompactLogix Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1768-L43\u003c\/strong\u003e is a high-performance programmable automation controller within the \u003cstrong\u003eCompactLogix\u003c\/strong\u003e family, specifically engineered to deliver robust computational execution for machine control and motion applications. This processing unit features a dual-backplane architecture that simultaneously hosts both 1768 high-speed communication or motion modules and 1769 Compact I\/O modules, providing flexible and integrated platform scaling. Outfitted with 2 MB of built-in nonvolatile user memory, the device coordinates complex ladder logic, structured text, function block, and sequential function chart programming structures. Industrial communication loops are supported through an integrated RS-232 serial port alongside flexible expansion options for EtherNet\/IP, ControlNet, and DeviceNet networking, enabling seamless connection paths to field arrays, human-machine interfaces, and enterprise networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUtilizes a dual-backplane layout supporting up to two 1768 modules and sixteen 1769 modules.\u003c\/li\u003e\n\u003cli\u003eIncludes 2 MB of standard built-in user memory for dense control logic and application execution.\u003c\/li\u003e\n\u003cli\u003eProvides a built-in non-isolated RS-232 serial communication port supporting DF1 and ASCII protocols.\u003c\/li\u003e\n\u003cli\u003eFeatures a standard power supply distance rating of 4 modules to optimize system stability.\u003c\/li\u003e\n\u003cli\u003eSupports versatile programming tasks via Relay Ladder, Structured Text, Function Block, and Sequential Function Chart languages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-axis synchronized motion control and precision robotic position paths.\u003c\/li\u003e\n\u003cli\u003eAssembly and packaging line machinery requiring fast local and distributed I\/O execution.\u003c\/li\u003e\n\u003cli\u003ePlant process orchestration loops featuring multi-network plant communication topologies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1768-L43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompactLogix 1768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable User Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompactFlash Card Slot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1784-CF128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Communication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 RS-232 serial port (DF1 or ASCII)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, ControlNet, DeviceNet (via expansion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Expansion Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 1768 modules, Sixteen 1769 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Distance Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Languages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay ladder, Structured Text, Function block, Sequential Function Chart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 Celsius (32...140 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...85 Celsius (-40...185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g panel mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 g @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the device directly onto a clean industrial DIN rail assembly or secure it onto an internal enclosure panel using the dedicated mounting holes.\u003c\/li\u003e\n\u003cli\u003ePosition the processing module within a maximum distance of 4 module slots from the system's matching 1768 power supply unit.\u003c\/li\u003e\n\u003cli\u003ePlace all high-speed 1768 expansion, motion, or communication modules directly between the power supply and the controller body.\u003c\/li\u003e\n\u003cli\u003eAttach local 1769 I\/O modules to the right side of the 1768 backplane structure, ensuring that any extra I\/O banks use their own dedicated power supply units.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695182934379,"sku":"1768-L43","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1768-l43-processor-module-avfqravzydq_e2fe9803-fd62-4dc3-8f00-cf31c63b027e.jpg?v=1766114359"},{"product_id":"allen-bradley-1756-ov16e-controllogix-fused-sinking-output-module","title":"Allen-Bradley 1756-OV16E ControlLogix Fused Sinking Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-OV16E\u003c\/strong\u003e is a 16-point digital DC output module designed for use within the ControlLogix chassis system. Operating within a 10 to 30V DC range, this sinking current output module provides individual electronic fusing per point to ensure robust circuit protection. It utilizes a Coordinated System Time (CST) Timestamped Fuse Data—Output Data communication format, enabling the module to transmit a Fuse Blown status along with the exact system clock value from the local chassis whenever a fuse blows or resets. This diagnostic capability allows for precise fault tracking and rapid troubleshooting in critical process control applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Point Sinking Outputs\u003c\/strong\u003e: Provides 16 distinct sinking current digital outputs operating between 10...30V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-Point Electronic Fusing\u003c\/strong\u003e: Individual electronic fuse protection across all 16 channels to isolate faults and protect field-side wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScheduled Outputs\u003c\/strong\u003e: Offers output synchronization referenced to the Coordinated System Time (CST) with a maximum synchronization variance of 16.7 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Fault States\u003c\/strong\u003e: Each point can be independently configured to hold its last state, turn on, or turn off (default) during a fault condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram Mode Configuration\u003c\/strong\u003e: Configurable states per point during Program mode, supporting hold last state, on, or off (default).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics\u003c\/strong\u003e: Returns real-time Fuse Blown status accompanied by local chassis system clock timestamps for both fuse blow and reset events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSolenoide valve control in automated assembly lines.\u003c\/li\u003e\n\u003cli\u003ePilot light and indicator panel management.\u003c\/li\u003e\n\u003cli\u003eInterfacing with DC inputs of secondary control devices or motor drives.\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose low-side (sinking) switching applications in discrete manufacturing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-OV16E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSinking Current Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronically fused per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCST Timestamped Fuse Data—Output Data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScheduled Outputs Synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.7 seconds maximum reference to CST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault States Per Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHold last state, On, Off (default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgram Mode States Per Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHold last state, On, Off (default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States \/ USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 mm x 35 mm x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eDIN Rail and Chassis Installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the ControlLogix chassis power supply is switched off before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the circuit board of the module with the top and bottom chassis guides in the designated slot.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the chassis until the top and bottom locking tabs click into place securely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring and Polarity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify all field-side power is disconnected before working on the terminal blocks.\u003c\/li\u003e\n\u003cli\u003eConnect the common positive rail (+V DC) to the field load, and route the return path through the module's sinking output terminals to the negative DC reference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper separation between low-voltage DC signals and high-voltage AC power lines within the enclosure wire ducts to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695183065451,"sku":"1756-OV16E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-ov16e-fused-sinking-output-module-pu3mz3ycvwq_b489b2ec-4c1e-4bb4-8ffe-867337451759.jpg?v=1766114364"},{"product_id":"allen-bradley-1756-synch-controllogix-synchlink-communication-module","title":"Allen-Bradley 1756-SYNCH ControlLogix SynchLink Communication Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe \u003cstrong\u003eAllen-Bradley 1756-SYNCH\u003c\/strong\u003e functions as a dedicated, high-speed fiber-optic communication interface that establishes deterministic data broadcasting and system clock synchronization across multiple control platforms. Designed to slot directly into any standard chassis assembly, this \u003cstrong\u003eSynchLink communication module\u003c\/strong\u003e enables peer-to-peer data consumption between independent controllers, allowing motion axis variables and drive coordination data to be transferred with minimal latency. By managing specialized fiber-optic frames via dedicated physical layer ports, the unit aligns the distributed system time bases required for highly integrated co-dependent automation processes.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDeterministic Data Transfer\u003c\/strong\u003e: Delivers synchronous communications with a fixed frame transmission speed of 50 microseconds.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFixed Data Throughput\u003c\/strong\u003e: Runs at a continuous SynchLink data rate of 5 Mbps for real-time motion and control distribution.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eOptical Multi-Chassis Linkage\u003c\/strong\u003e: Integrates 2 localized fiber-optic cable ports utilizing a 650 nm operating wavelength.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eOptimized Frame Architecture\u003c\/strong\u003e: Uses a highly structured frame layout containing 3 flag bytes, 1 control byte, 24 data bytes, and a 2-byte cyclic redundancy check (CRC) field for transmission verification.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003ePower Infrastructure Support\u003c\/strong\u003e: Engineered to interface seamlessly within backplanes powered by either standard or redundant power supply modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMulti-chassis master\/slave system clock synchronization in high-speed manufacturing lines.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCoordinated drive systems and real-time motion control distribution across separated industrial racks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eInter-controller consumption of critical motion axis variables without traditional network bandwidth overhead.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1756-SYNCH\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSynchLink Communication Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Line\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eControlLogix\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eGTIN\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10612598275301\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eUPC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10612598307699\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eData Rate \/ Baud Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 Mbps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Wavelength\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e650 nm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFrame Processing Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 us\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eBackplane Current Draw (5.1V DC)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1200 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eBackplane Current Draw (24V DC)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3 mA (User text context indicates up to 3 mA; raw source parameters note 2.5 mA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Dissipation (Max)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e6.2 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eThermal Dissipation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e21.2 BTU\/hr\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFiber Medium Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e200-230 micron Hard-Clad Silica (HCS) cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFiber Termination Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eVersalink V-System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePermissible Cable Length Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 1 - 300 m;\"\u003e1 - 300 m\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInternal Target Wire Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e20 AWG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Enclosure Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eNone (open-style)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 Celsius to 60 Celsius (32 Fahrenheit to 140 Fahrenheit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Shock Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e30g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnited States \/ USA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.00 lbs (0.45 kg)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e21.5 x 14.0 x 4.8 cm (8.46 x 5.51 x 1.89 in.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe 1756-SYNCH module establishes explicit physical-layer communication configurations that dictate the use of specialized 200-230 micron Hard-Clad Silica (HCS) glass lines with Versalink V-System termination. It cannot be directly substituted with standard multi-mode or single-mode LC\/ST telecommunication fiber interfaces. For specific layout extensions, approved functional accessories include the 1403-CFxxx fiber-optic pre-assembled cable layouts or the simplex 200 um HCP-M0200T V01RK raw cable lines.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nA major installation risk involves ignoring fiber-optic link attenuation limits across long physical spans up to the 300 m cap. Ensure the core fiber run is free from tight routing bends that violate minimum radius restrictions, as micro-bending causes massive light loss at the 650 nm operating wavelength, throwing CRC link faults inside the frame parameter checker. Ambient particulates also threaten the interface; because the module uses an open enclosure design, deploying this unit in environments that do not meet clean, dry industrial specifications will foul the transceiver ports, destabilizing the 50 us clock alignment loop.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Isolate and completely cut off all primary electrical utilities feeding the hosting control chassis backplane before sliding or uncoupling the communication assembly. Handling module insertion steps while the rack contains active residual voltage risks triggering unexpected backplane noise spikes, communication drops on adjacent nodes, or component degradation.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eIdentify an open slot inside the designated ControlLogix chassis and inspect the internal backplane connector pins for structural alignment.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eAlign the module circuit board with the top and bottom card guides of the chosen slot tracking.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePress the module firmly into the slot until the top and bottom housing tabs snap securely flush with the chassis frame.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eRemove the protective dust caps from the 2 optical ports and clean the transceivers before inserting the Versalink V-System fiber terminations.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e5\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSecure the fiber-optic cabling in the wire ducting, verifying that the physical link length remains between 1 m and 300 m without strict bends.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695183163755,"sku":"1756-SYNCH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-synch-synchlink-communication-module-egv5mzyonjk_6dbb8eb1-5aba-4032-83b2-889d4a0e4d4d.jpg?v=1766114367"},{"product_id":"allen-bradley-1769-if4-compactlogix-analog-input-module","title":"Allen-Bradley 1769-IF4 CompactLogix Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1769-IF4\u003c\/strong\u003e is a 4-channel analog input module designed for CompactLogix and MicroLogix 1500 control systems. This module provides high-resolution conversion of differential analog signals into digital values for industrial automation applications. It supports both voltage and current input configurations, enabling direct interfacing with analog field instruments such as transmitters, sensors, and flow meters. The \u003cstrong\u003e1769-IF4\u003c\/strong\u003e features advanced hardware filtering to attenuate electronic noise and transient disturbances, ensuring reliable data acquisition in challenging industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour independently configurable differential input channels.\u003c\/li\u003e\n\u003cli\u003eSelectable voltage and current signal configurations for broad field instrument compatibility.\u003c\/li\u003e\n\u003cli\u003eHigh-resolution analog-to-digital conversion up to 14 bits unipolar or 14 bits plus sign bipolar.\u003c\/li\u003e\n\u003cli\u003eEffective operational isolation between the backplane logic circuit and field-side inputs.\u003c\/li\u003e\n\u003cli\u003eBuilt-in input filtering to minimize electrical noise and transient signal variations.\u003c\/li\u003e\n\u003cli\u003eRemovable terminal block allowing convenient wiring and module maintenance without disconnecting cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlow rate, pressure, and thermal processing loop control.\u003c\/li\u003e\n\u003cli\u003eMachine and process monitoring via factory sensor networks.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment monitoring networks.\u003c\/li\u003e\n\u003cli\u003eIntegration of chemical injection and mixing control instrumentation.\u003c\/li\u003e\n\u003cli\u003eSCADA remote telemetry unit configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 32.8144%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 66.8618%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e1769-IF4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003eCompactLogix \/ Compact I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e4-Channel Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e4 differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eInput Signal Range (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003ePlus \/ minus 10V, 0 to 10V, 0 to 5V, 1 to 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eInput Signal Range (Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e0 to 20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e14 bits (Unipolar); 14 bits plus sign (Bipolar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eBus Current Draw (5V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eBus Current Draw (24V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e2.63 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e500V AC or 710V DC for 1 minute (qualification test), inputs to bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eRated Working Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e30V AC \/ 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e0 to 60 degC (32 to 140 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e-40 to 85 degC (-40 to 185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e5% to 95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eVibration (Operating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e5g at 10 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e118 x 35 x 87 mm (4.65 x 1.38 x 3.43 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eHeight with Mounting Tabs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003e138 mm (5.43 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.8144%;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.8618%;\"\u003eMalaysia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Placement:\u003c\/strong\u003e Mount the module onto a standard DIN rail or directly to a panel using integrated mounting tabs. Maintain a secure connection with adjacent Compact I\/O modules via the built-in locking mechanism.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Constraints:\u003c\/strong\u003e Ensure the configuration complies with distance ratings and backplane current limits. The module draws 120 mA at 5V DC and 60 mA at 24V DC from the system backplane power rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Use high-quality twisted-pair shielded cable for all analog signal paths. Connect the cable shield to a clean ground point at the controller end only to mitigate EMI\/RFI issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route low-voltage analog signal wires through dedicated conduits separated from high-voltage motor power lines and AC control wiring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695184277867,"sku":"1769-IF4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1769-if4-i-o-module-rdpp32rlocs_26b1c9dd-32f3-4c75-bf68-da1b69f71083.jpg?v=1766114397"},{"product_id":"allen-bradley-1756-og16-controllogix-16-point-ttl-digital-output-module","title":"Allen-Bradley 1756-OG16 ControlLogix 16 Point TTL Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-OG16\u003c\/strong\u003e is a ControlLogix digital output module designed to provide 16 distinct points of 5V DC TTL outputs. Operating on a Low True logic structure, this module allows seamless interfacing with TTL-compatible field devices and logic circuits within industrial automation environments. It integrates into the ControlLogix chassis, using Producer\/Consumer technology to efficiently share output status and module health diagnostics with multiple controllers across the local network architecture.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 digital output channels organized into two isolated groups of 8 points.\u003c\/li\u003e\n\u003cli\u003eLow True logic operation suitable for 0 to 5V DC TTL applications.\u003c\/li\u003e\n\u003cli\u003eSupport for electronic keying via software configuration to prevent incorrect slot placement.\u003c\/li\u003e\n\u003cli\u003eFront-panel status indicators providing clear visual diagnostics for each I\/O point and overall module status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed semiconductor manufacturing equipment interfaces\u003c\/li\u003e\n\u003cli\u003eLaboratory automation and testing environments\u003c\/li\u003e\n\u003cli\u003eIntegration with custom logic circuits and electronic control panels requiring 5V TTL signaling\u003c\/li\u003e\n\u003cli\u003eLow-power digital signaling and discrete state control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTTL Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16 (8 points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Category\u003c\/td\u003e\n\u003ctd\u003e5V DC TTL (Low True)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e4.5 to 5.5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw (5.1V DC)\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw (24V DC)\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Backplane Power\u003c\/td\u003e\n\u003ctd\u003e1.28 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current per Point\u003c\/td\u003e\n\u003ctd\u003e24 mA sink, 0.4 mA source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation, Max\u003c\/td\u003e\n\u003ctd\u003e1.0 W @ 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50V continuous, basic insulation type (outputs-to-backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Terminal Block (RTB)\u003c\/td\u003e\n\u003ctd\u003e1756-TBNH, 1756-TBSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTB Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.4 to 0.7 N-m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the ControlLogix chassis power is managed properly; while the module supports Removal and Insertion Under Power (RIUP), adhering to local plant safety guidelines is recommended.\u003c\/li\u003e\n\u003cli\u003eAlign the circuit board of the module with the top and bottom chassis card guides, sliding it smoothly into the slot until the locking tabs snap firmly into position.\u003c\/li\u003e\n\u003cli\u003eWire the field connections using a compatible 20-pin Removable Terminal Block (RTB), ensuring correct pin definitions for the low-voltage TTL lines.\u003c\/li\u003e\n\u003cli\u003eRoute the low-voltage TTL signal wires away from high-voltage AC lines to mitigate potential EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eImplement proper grounding practices for the chassis to maintain signal integrity and system protection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695184802155,"sku":"1756-OG16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-og16-transistor-logic-output-module-330vcf2my25_94cbd099-0e27-4e28-8ef8-1f3465c5f9a5.jpg?v=1766114416"},{"product_id":"allen-bradley-1756-tbch-controllogix-removable-terminal-block","title":"Allen-Bradley 1756-TBCH ControlLogix Removable Terminal Block","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe \u003cstrong\u003eAllen-Bradley 1756-TBCH\u003c\/strong\u003e is a 36-position cage-clamp removable terminal block (RTB) designed to provide reliable field-side wiring connections for \u003cstrong\u003eBulletin 1756 I\/O modules\u003c\/strong\u003e within the \u003cstrong\u003eControlLogix\u003c\/strong\u003e system architecture. This component mounts directly onto the front section of the active I\/O module, offering an interface that permits rapid system upgrades and maintenance without disconnecting independent field conductors. Enclosed in a compact, low-profile housing, the terminal block optimizes layout spacing inside tightly packed industrial marshalling cabinets and enclosures while supporting single and double wire connectivity options.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003e36-Pin Dense Layout\u003c\/strong\u003e: Accommodates high-density digital and analog I\/O wiring paths across a specialized 36-position interface.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eCage-Clamp Termination\u003c\/strong\u003e: Utilizes a high-retention cage-clamp mechanism that ensures gas-tight connections and vibration resistance.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eMulti-Conductor Routing\u003c\/strong\u003e: Full structural support for both single-wire and double-wire terminations per point to optimize cross-terminal jumps.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eLow-Profile Design\u003c\/strong\u003e: Compact mechanical footprint enables easy closing of chassis front covers and reduces enclosure depth demands.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRemovable Operation\u003c\/strong\u003e: Plugs directly into the front of standard I\/O housings, accelerating hot-swap maintenance and replacement routines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh-density digital and analog I\/O module wiring inside ControlLogix systems.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eProcess plant marshalling panels where swift disconnection and module hot-swapping are required.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eFactory automation systems subject to consistent ambient mechanical vibration requiring stable cage-clamp retention.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1756-TBCH\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRemovable Terminal Block (RTB)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Line\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eControlLogix\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eUPC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e612598171835\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCompatible Hardware\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eBulletin 1756 I\/O Modules\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eClamp Mechanical Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCage-Clamp\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eScrew Fastening Torque\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.5 Nm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMaximum Tool Width\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3.2 mm slotted screwdriver\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSingle Wire Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSupported\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDouble Wire Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSupported\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 Celsius to 60 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 Celsius to 85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnited States \/ USA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.31 lbs (0.14 kg)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e15.2 x 5.1 x 3.8 cm (6.0 x 2.0 x 1.5 in.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe 1756-TBCH features a high-density 36-position pitch specifically engineered for 36-pin I\/O module variants. It cannot be used interchangeably with the 20-position variants, such as the 1756-TBNH screw-clamp or 1756-TBS6H spring-clamp terminal blocks. For heavy-duty automation setups where intense vibrational forcing is an operational risk, engineers may select the alternative 36-position spring-clamp model (1756-TBSH) to prevent minor wire movement over long production cycles.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDuring panel commissioning, a frequent field error is utilizing standard electrical screwdrivers exceeding the designated 3.2 mm threshold. Tool heads that are too wide can warp or fracture the internal cage walls, causing short circuits or degrading isolation between adjacent high-density pins. Additionally, failure to set wire termination tool torque to precisely 0.5 Nm may lead to loose contact points under continuous ambient thermal swelling, while over-tightening can strip the screw thread within the block assembly.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Isolate and completely cut all field-side auxiliary loops and source power feeds before attaching or unclamping the terminal block assembly. Inserting a wired terminal onto a live control module can cause localized voltage arcs, which can trigger control loop logic faults, permanent board failure, or combustion hazards in hazardous operational areas.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eInspect the tracking alignment guides on both the front interface of the 1756 module and the internal grooves of the terminal block.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eStrip field wire ends cleanly to ensure no frayed copper strands remain exposed beyond the physical boundary of the cage plate.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eInsert copper wire lines neatly into the intended cage positions, verifying whether single or double configurations match your electrical schematic layout.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eTighten each terminal screw to exactly 0.5 Nm using a calibrated torque driver fitted with a 3.2 mm slotted blade.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e5\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePush the fully wired block assembly smoothly onto the front pins of the I\/O module until the locking mechanism latches firmly into place.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695184965995,"sku":"1756-TBCH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-tbch-removable-terminal-block-n3ayy1b4e2s_f0eed9e5-f1db-490a-872f-240f9c3c101d.jpg?v=1766114421"},{"product_id":"allen-bradley-1756-of6vi-controllogix-isolated-analog-output-voltage-module","title":"Allen-Bradley 1756-OF6VI ControlLogix Isolated Analog Output Voltage Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eAllen-Bradley \u003cstrong\u003e1756-OF6VI\u003c\/strong\u003e is a high-performance analog output module designed for integration into the \u003cstrong\u003eControlLogix\u003c\/strong\u003e control system architecture. This module provides precise voltage signaling to field-side instruments, including control valves, actuators, and motor drives, allowing for accurate closed-loop regulation in automated industrial systems. Featuring six independent channels, the \u003cstrong\u003e1756-OF6VI\u003c\/strong\u003e delivers reliable process control by generating steady analog output waveforms across localized automated frameworks.\u003c\/p\u003e\n\u003cp\u003eThe standout feature of this module is its robust electrical architecture, which incorporates per-point isolation to ensure that each channel is completely separated from adjacent circuits. This channel-to-channel separation provides substantial signal integrity by eliminating ground loop disturbances and preventing common-mode electrical noise from propagating through the internal system backplane. Built with an intuitive front-facing status display, the module gives field technicians direct visibility into operational modes and health checks, ensuring swift diagnostic verification during standard plant operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-Point Channel Isolation:\u003c\/strong\u003e Features six individually isolated voltage output channels that protect control loops from ground differentials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable Signal Profiles:\u003c\/strong\u003e Delivers highly accurate bipolar voltage ranges to interface seamlessly with a wide selection of industrial industrial control elements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-Board Diagnostics:\u003c\/strong\u003e Front-panel indicators provide rapid visual feedback regarding active calibration status, channel errors, and overall device health.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis-Based Integration:\u003c\/strong\u003e Installs directly into any standard slot of a local or remote distributed chassis linked via industrial industrial network communication networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy control of electronic proportional actuators and positioners.\u003c\/li\u003e\n\u003cli\u003eSpeed and torque references for variable frequency drives (VFDs) in factory automation.\u003c\/li\u003e\n\u003cli\u003eIsolated setpoint signaling for remote sub-systems and distributed control loops.\u003c\/li\u003e\n\u003cli\u003eCalibration test benches and simulation systems requiring distinct isolated voltage outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-OF6VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-10.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V continuous between outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecial Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePer point isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Health, In Calibration, Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e612598164660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Mounting:\u003c\/strong\u003e Ensure that the system backplane power is disconnected before installing the unit. Align the module with the plastic card guides of the chassis and push firmly until the locking tabs snap securely into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable Terminal Block Connection:\u003c\/strong\u003e Field wiring must be landed on a separately ordered removable terminal block (RTB) or an interface module (IFM). Tighten all terminal screws to the recommended factory torque specifications to avoid loose contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Mitigation:\u003c\/strong\u003e Always observe standard ESD countermeasures, such as wearing a grounded wrist strap or maintaining contact with a conductive chassis surface, when handling the unshielded circuit boards of the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Path Separation:\u003c\/strong\u003e Keep analog output signaling lines isolated from high-voltage AC power paths and motor lead cables within the panel enclosure to prevent electro-magnetic induction from degrading signal accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695185424747,"sku":"1756-OF6VI","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-of6vi-isolated-analog-output-module-wubgoxm5zyb_4181445f-acce-4a31-8ff1-06a887f7da7a.jpg?v=1766114438"},{"product_id":"allen-bradley-1756-l73-controllogix-8-mb-controller","title":"Allen-Bradley 1756-L73 ControlLogix 8 MB Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-L73\u003c\/strong\u003e is a ControlLogix 5570 programmable automation controller designed to deliver high-performance control and data processing for demanding industrial automation applications. Equipped with \u003cstrong\u003e8 MB\u003c\/strong\u003e of user memory and \u003cstrong\u003e0.98 MB\u003c\/strong\u003e of dedicated I\/O memory, the \u003cstrong\u003e1756-L73\u003c\/strong\u003e provides real-time control, high-speed data execution, and seamless integration across complex architectures. Featuring an integrated USB programming port and pre-installed Secure Digital (SD) non-volatile memory storage, it provides robust, flexible controller performance within the ControlLogix 1756 platform.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 8 MB of user memory and 0.98 MB of dedicated I\/O memory\u003c\/li\u003e\n\u003cli\u003eSupports up to 32 controller tasks with up to 1000 programs per task\u003c\/li\u003e\n\u003cli\u003eIncludes 1 GB Secure Digital (SD) card (1784-SD1) for non-volatile memory storage\u003c\/li\u003e\n\u003cli\u003eEquipped with a USB 2.0 full-speed front port for local programming and configuration\u003c\/li\u003e\n\u003cli\u003eUtilizes capacitor-based energy storage modules (1756-ESMCAP) eliminating the need for lithium batteries\u003c\/li\u003e\n\u003cli\u003eSupports up to 128,000 digital I\/O and 4,000 analog I\/O points\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed batch processing and discrete manufacturing control\u003c\/li\u003e\n\u003cli\u003ePlant-wide process control and complex motion management\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment facility automation\u003c\/li\u003e\n\u003cli\u003eOil, gas, and energy generation control systems\u003c\/li\u003e\n\u003cli\u003eAutomated material handling and packaging machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-L73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5570 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Memory\u003c\/td\u003e\n\u003ctd\u003e0.98 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Volatile Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB Secure Digital (SD) card (1784-SD1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e128,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e4,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e128,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw at 1.2V DC\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw at 5.1V DC\u003c\/td\u003e\n\u003ctd\u003e800 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.5 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 full-speed (12 Mbps), Type B connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 full-speed programming\/configuration port (Type B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003eControlLogix 1756 backplane connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurn off chassis power or verify area non-hazardous status before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the controller module with the top and bottom guides of any available chassis slot.\u003c\/li\u003e\n\u003cli\u003eSlide the module firmly into the slot until the top and bottom levers snap into position.\u003c\/li\u003e\n\u003cli\u003eEnsure the energy storage module (1756-ESMCAP) is securely seated in the controller unit.\u003c\/li\u003e\n\u003cli\u003eConnect the USB programming cable only for temporary local configuration and maintenance access.\u003c\/li\u003e\n\u003cli\u003eMaintain clear ventilation paths above and below the chassis to prevent thermal buildup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ec-UL-us Listed Industrial Control Equipment (UL File E65584)\u003c\/li\u003e\n\u003cli\u003eUL Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations (UL File E194810)\u003c\/li\u003e\n\u003cli\u003eCE Marked for European Union EMC Directives (EN 61326-1, EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n\u003cli\u003eRCM Australian Radiocommunications Compliance\u003c\/li\u003e\n\u003cli\u003eKC Korean Class A EMC Certification\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695185457515,"sku":"1756-L73","price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1756-L73_2.jpg?v=1783590474"},{"product_id":"allen-bradley-1769-ob32-compactlogix-compact-i-o-solid-state-dc-output-module","title":"Allen-Bradley 1769-OB32 CompactLogix Compact I\/O Solid-State DC Output Module","description":"\u003cp\u003eThe \u003cstrong\u003e1769-OB32\u003c\/strong\u003e is a high-density 32-point discrete solid-state electronic module designed to provide sourcing direct-current switching capabilities within the \u003cstrong\u003eCompactLogix \/ Compact I\/O\u003c\/strong\u003e hardware infrastructure. It converts electronic control logic commands from a central processor into discrete 24 VDC output paths divided into two separate, isolated groups of 16 channels each. This hardware allows low-power programmatic actuation of direct-current devices including industrial control relays, indicators, display panels, and small solenoid valves. The assembly interfaces natively with \u003cstrong\u003eCompactLogix\u003c\/strong\u003e automation systems or functions as distributed field hardware through a \u003cstrong\u003eMicroLogix\u003c\/strong\u003e controller expansion link or network adapter module. System interlocking is maintained through an optoelectronic safety barrier providing a continuous 30 VDC working isolation voltage profile to protect internal system backplane components against plant field line anomalies.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Channel Array\u003c\/strong\u003e: Packs 32 discrete solid-state source-type outputs inside a single-slot module footprint to save panel space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Group Isolation\u003c\/strong\u003e: Separates channels into two distinct electrical banks of 16 outputs, permitting independent field power supply routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Short-Circuit Protection\u003c\/strong\u003e: Incorporates an integrated electronic protection matrix that auto-detects thermal\/current faults to minimize down-time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Slot Keying\u003c\/strong\u003e: Features integrated mechanical tongue-and-groove guide rails to prevent incorrect alignment during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Diagnostic LED Panel\u003c\/strong\u003e: Provides 32 separate green indicators to deliver real-time channel state visualization for point-level testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable Terminal Block\u003c\/strong\u003e: Employs a 40-pin finger-safe terminal block with a latching door mechanism to enable hot-swapping sequences without wire removal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDriving localized low-power direct current pneumatic solenoid manifolds.\u003c\/li\u003e\n\u003cli\u003eInterfacing control logic to discrete input channels of motor speed controllers.\u003c\/li\u003e\n\u003cli\u003eMain operator desk visual illumination lamps and pilot sounders.\u003c\/li\u003e\n\u003cli\u003eActuating discrete interface auxiliary relays in process manufacturing lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1769-OB32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompactLogix \/ Compact I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-state 24V DC Source Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs Per Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 sourcing outputs (2 groups of 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 VDC to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum On-State Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point @ 60 Celsius \/ 1.0 A per point @ 30 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Per Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 A @ 60 Celsius \/ 8.0 A @ 30 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Module Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 A @ 60 Celsius \/ 16.0 A @ 30 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA @ 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Off-State Leakage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mA @ 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum On-State Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 VDC @ 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Turn-On Time Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Turn-Off Time Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking Isolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 VDC continuous, basic insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Boundary Mapping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup-to-group and group-to-system backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Type Test Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTested @ 710 VDC for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Distance Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 modules maximum from system power supply module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Relative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Hardware Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail installation or Panel Mount with screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Width Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVDC 1 (+)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Power Supply Input Reference for Group 1 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOUT 0 to OUT 15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSourcing Output Channel 0 through Channel 15 (Group 1 Matrix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM 1 (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Current Common Ground Return for Group 1 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVDC 2 (+)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Power Supply Input Reference for Group 2 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOUT 16 to OUT 31\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSourcing Output Channel 16 through Channel 31 (Group 2 Matrix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM 2 (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Current Common Ground Return for Group 2 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Connection Latching\u003c\/strong\u003e: Align the side tongue-and-groove tracks precisely before mating the expansion connector. Slide the integrated mechanical bus lever completely to the left position to lock the backplane connectors firmly into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Proximity Matching\u003c\/strong\u003e: Do not exceed the strict 8-slot distance limitation boundary when placing the hardware module relative to the nearest system power supply block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring Entry Limits\u003c\/strong\u003e: Connect only copper wire configurations rated for 75 degC minimum. Single wire gauges must fall inside the 0.32 to 0.82 mm2 (22 to 18 AWG) window with insulation stripping adjusted to 11 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection Practices\u003c\/strong\u003e: Ground the hosting DIN rail or backplane framework back to an earth anchor point using heavy gauge wire to mitigate transient radio-frequency or electromagnetic fields.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDetailed Installation Reference\u003c\/h3\u003e\n\u003cp\u003eFor comprehensive step-by-step physical mounting, wiring arm configurations, and detailed channel layout diagrams, please refer to the official installation publication:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1769-in031_-en-p.pdf?v=1780145237\"\u003e👉 \u003cstrong\u003eClick Here to Download the Full Allen-Bradley 1769-OB32 Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this specific model function as a sourcing type or a sinking type output card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This module functions exclusively as a sourcing type device, meaning it switches the positive voltage potential (+VDC) from the supply line out to the field load terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can Group 1 and Group 2 be powered by completely separate power supplies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, because Group 1 and Group 2 are completely isolated from each other, you can use two distinct 24V DC power sources landed on their respective VDC and COM terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum current load allowed on a single channel point when operating at full 60 Celsius temperature specs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: When running at an ambient temperature of 60 Celsius, the maximum continuous output current limit is 0.5 A per individual channel point.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695185555819,"sku":"1769-OB32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1769-ob32-machine-control-kiqifbfu0pa_a1b1c9eb-6f18-40e5-a34e-8d5eaf9d14ef.jpg?v=1766114446"},{"product_id":"allen-bradley-1756-ob16is-controllogix-scheduled-isolated-output-module","title":"Allen-Bradley 1756-OB16IS ControlLogix Scheduled Isolated Output Module","description":"\u003cp\u003eThe \u003cstrong\u003e1756-OB16IS\u003c\/strong\u003e is a digital output execution component built for the ControlLogix system configuration. It functions within a nominal 12\/24V DC voltage envelope, featuring 16 channels that are isolated individual points designed to secure downstream circuitry against cross-signal disturbance and transient spikes. This module integrates 8 scheduled output points designed to enable precise synchronization matching coordinated machine sequences with reference to the Coordinated System Time. It installs inside standard control slots, interfacing with industrial field loads via specified removable termination assemblies to provide deterministic actuation and steady processing states under multiple manufacturing control configurations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncorporates 16 isolated output channels providing basic insulation between output points and backplane circuits.\u003c\/li\u003e\n\u003cli\u003eFeatures 8 scheduled outputs allowing time-stamped task performance linked directly with coordinated control architecture.\u003c\/li\u003e\n\u003cli\u003eProvides sinking or sourcing load matching with an execution range spanning 10V DC to 30V DC field operations.\u003c\/li\u003e\n\u003cli\u003eDelivers continuous visual verification of independent output channel execution states and module hardware health.\u003c\/li\u003e\n\u003cli\u003eSupports electronic, software-configurable keying options to enforce accurate hardware module matching upon slot replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed sorting and discrete tracking machinery requiring timed sequence control.\u003c\/li\u003e\n\u003cli\u003eSolenoid valve switching loops and isolated pilot relay driving circuits.\u003c\/li\u003e\n\u003cli\u003eMulti-zone industrial heating elements requiring synchronized control pulses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e16 individually isolated, 8 scheduled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePilot Duty\u003c\/td\u003e\n\u003ctd\u003e2 A (DC-13SQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Category\u003c\/td\u003e\n\u003ctd\u003e12\/24V DC sink\/source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10...30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Delay Time (Off to On)\u003c\/td\u003e\n\u003ctd\u003e1 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Delay Time (On to Off)\u003c\/td\u003e\n\u003ctd\u003e2 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw @ 5.1V\u003c\/td\u003e\n\u003ctd\u003e350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw @ 24V\u003c\/td\u003e\n\u003ctd\u003e2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Backplane Power\u003c\/td\u003e\n\u003ctd\u003e1.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation, Max\u003c\/td\u003e\n\u003ctd\u003e3.6 W @ 60 degC (140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e12.28 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current Per Point, Max\u003c\/td\u003e\n\u003ctd\u003e0.5 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Drop, Max\u003c\/td\u003e\n\u003ctd\u003e1.2V DC @ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Per Point, Max\u003c\/td\u003e\n\u003ctd\u003e2 A @ 30 degC (86 degF), 1 A @ 60 degC (140 degF) (linear derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Per Module, Max\u003c\/td\u003e\n\u003ctd\u003e8 A @ 30 degC (86 degF), 4 A @ 60 degC (140 degF) (linear derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current Per Point\u003c\/td\u003e\n\u003ctd\u003e4 A for 10 ms per point, repeatable every 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current, Min\u003c\/td\u003e\n\u003ctd\u003e1 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScheduled Outputs Synchronization\u003c\/td\u003e\n\u003ctd\u003eWithin 16.7 s max, reference to the Coordinated System Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStates in Fault Mode Per Point\u003c\/td\u003e\n\u003ctd\u003eHold last state, On or Off (Off is default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStates in Program Mode Per Point\u003c\/td\u003e\n\u003ctd\u003eHold last state, On or Off (Off is default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Keying\u003c\/td\u003e\n\u003ctd\u003eElectronic, software configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Terminal Block\u003c\/td\u003e\n\u003ctd\u003e1756-TBCH, 1756-TBS6H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTB Keying\u003c\/td\u003e\n\u003ctd\u003eUser-defined mechanical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Width\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Category\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Type\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature, Operating\u003c\/td\u003e\n\u003ctd\u003e0...60 degC (32...140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature, Nonoperating\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC (-40...185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e2 g @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock, Operating\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock, Nonoperating\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure conductor routing follows specified guidelines for Wire Category 1 paths to reduce crosstalk with high-voltage power components.\u003c\/li\u003e\n\u003cli\u003eUse only approved ControlLogix Removable Terminal Blocks, specifically models 1756-TBCH or 1756-TBS6H, to wire external field outputs.\u003c\/li\u003e\n\u003cli\u003eSet the software-based electronic keying attributes accurately within the project configuration to prevent mismatched module replacement errors.\u003c\/li\u003e\n\u003cli\u003eApply appropriate current derating factors when operating ambient conditions rise, limiting per-point current to 1 A when reaching 60 degC.\u003c\/li\u003e\n\u003cli\u003eMount the open-style chassis assembly inside an enclosure that offers appropriate protective barrier sealing against environmental particulates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecULus Listed Industrial Control Equipment (UL File E65584)\u003c\/li\u003e\n\u003cli\u003ecULus Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations (UL File E194810)\u003c\/li\u003e\n\u003cli\u003eCE (European Union 2014\/30\/EU EMC Directive, EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2; 2014\/35\/EU LVD Directive, EN 61131-2)\u003c\/li\u003e\n\u003cli\u003eRCM (Australian Radiocommunications Act, EN 61000-6-4)\u003c\/li\u003e\n\u003cli\u003eATEX (European Union 2014\/34\/EU ATEX Directive, EN IEC 60079-0, EN IEC 60079-7, II 3 G Ex ec IIC T4 Gc, UL22ATEX2820X)\u003c\/li\u003e\n\u003cli\u003eIECEx (IEC 60079-0, IEC 60079-7, II 3 G Ex ec IIC T4 Gc, IECEx UL 22.0065X)\u003c\/li\u003e\n\u003cli\u003eUKex (UKEX Regulation 2016 No. 1107, Equipment protection by increased safety \"e\", UL22UKEX2602X, Zone 2 classification)\u003c\/li\u003e\n\u003cli\u003eKC (Korean Registration of Broadcasting and Communications Equipment, Article 58-2 of Radio Waves Act)\u003c\/li\u003e\n\u003cli\u003eUKCA (2016 No. 1091, 2016 No. 1101, 2016 No. 1107, 2012 No. 3032)\u003c\/li\u003e\n\u003cli\u003eMorocco (Arrête ministériel n° 6404-15)\u003c\/li\u003e\n\u003cli\u003eCCC (2020122309111998, CNCA-C23-01 CCC Implementation Rule Explosion-Proof Electrical Products)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695185752427,"sku":"1756-OB16IS","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-ob16is-digital-output-module-bfscivrzmyj_be101ea4-06b7-4bb4-a140-54da94b198d2.jpg?v=1766114453"},{"product_id":"allen-bradley-1756-m16se-controllogix-sercos-interface-module","title":"Allen-Bradley 1756-M16SE ControlLogix SERCOS Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003e1756-M16SE\u003c\/strong\u003e is a chassis-based motion control module that enables multi-axis closed-loop servo synchronization through a centralized network setup. This interface hardware links software execution tracks inside a central processing host directly to distributed smart drives by establishing a single digital fiber-optic medium connection, eliminating up to 18 traditional discrete signal wires for every single active axis. The device supports real-time transmission vectors across \u003cstrong\u003eSERCOS interface\u003c\/strong\u003e parameters, delivering bidirectional cyclic communication loops to update position command points and upload diagnostic telemetry arrays simultaneously. Architected to operate within standard system racks, the module plugs directly into any available linear slot to control up to 16 independent servo drives under strict position, velocity, or torque loops.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Link Optoelectronic Port\u003c\/strong\u003e: Employs a digital fiber-optic communication terminal to replace complex multi-wire discrete physical bundles per axis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Synchronized Control\u003c\/strong\u003e: Manages closed-loop operational variables for up to 16 independent servo drive units simultaneously from one slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Drive Operating Modes\u003c\/strong\u003e: Supports flexible control switching profiles including real-time position, velocity, and torque regulation loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Agility\u003c\/strong\u003e: Mounts directly into any standard system rack position to match custom configuration blueprints.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Cyclic Diagnostics\u003c\/strong\u003e: Maintains a continuous double-sided feedback stream between controller and drive for tracking fault states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-axis coordinated packaging lines and sorting conveyor systems.\u003c\/li\u003e\n\u003cli\u003eHigh-precision positioning tables and material handling pick-and-place systems.\u003c\/li\u003e\n\u003cli\u003eSynchronized winding machinery, textile production, and continuous web handling.\u003c\/li\u003e\n\u003cli\u003eClosed-loop servo feed control in automotive and heavy assembly machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-M16SE \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSERCOS Interface Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Drives, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSERCOS Data Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Mbps or 8 Mbps \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSERCOS Cycle Time @ 4 Mbps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 ms (up to 2 drives), 1 ms (up to 4 drives), 2 ms (up to 8 drives) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSERCOS Cycle Time @ 8 Mbps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 ms (up to 4 drives), 1 ms (up to 8 drives), 2 ms (up to 16 drives) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrive Control Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePosition, velocity, and torque \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw @ 5.1V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e760 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw @ 24V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis-based, any slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Chassis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Power Supplies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-PA72\/C, 1756-PA75\/B, 1756-PB72\/C, 1756-PB75\/B, 1756-PC75\/B, 1756-PH75\/B \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Power Supplies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-PA75R, 1756-PB75R, 1756-PSCA2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlastic Fiber-Optic Cables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2090-SCEPxx-0 (non-jacketed CPE), 2090-SCVPxx-0 (standard PVC), 2090-SCNPxx-0 (nylon jacket) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlass Fiber-Optic Cables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2090-SCVGxx-0 (standard PVC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open-style) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC (32 degF to 140 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC (-40 degF to 185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% noncondensing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration (IEC 60068-2-6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 g @ 10 to 500 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock (IEC 60068-2-27)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Shock (IEC 60068-2-27)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment\u003c\/strong\u003e: Ensure the keying tabs match the target rack slot before inserting the hardware to prevent twisting the inner connector path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber-Optic Cable Radius Constraints\u003c\/strong\u003e: Maintain the official minimal bend boundaries when pulling the core plastic or glass fiber lines to prevent high optical loss profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation Passages\u003c\/strong\u003e: Verify that surrounding cable trays do not block upper or lower chassis slots, preserving natural convective cooling across the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Sizing Requirements\u003c\/strong\u003e: Sum the combined 5.1 VDC and 24 VDC backplane current draws before initializing startup routines to prevent overcurrent trips.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-UL-us\u003c\/strong\u003e: UL Listed Industrial Control Equipment, certified for US and Canada (See UL File E65584); UL Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE\u003c\/strong\u003e: European Union 2004\/108\/IEC EMC Directive, compliant with EN 61326-1 (Meas.\/Control\/Lab., Industrial Requirements), EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions), and EN 61136-2 (Programmable Controllers Clause 8, Zone A \u0026amp; B).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-Tick\u003c\/strong\u003e: Australian Radiocommunications Act, compliant with AS\/NZS CISPR 11 (Industrial Emissions).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum number of servo axes this specific model can handle simultaneously?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eA: This module can handle a maximum of 16 drives or motion axes across the optical loop configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this interface link transmit torque control commands directly to a compatible servo drive?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eA: Yes, it inherently supports full position, velocity, and torque regulation modes across the real-time communication ring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of fiber-optic cables can be applied to link the module to field drives?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eA: It supports specified 2090 series cables, including non-jacketed CPE, standard PVC, nylon-jacketed plastic options, and standard PVC glass fiber lines.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695185850731,"sku":"1756-M16SE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-m16se-sercos-interface-module-efjujxlwuu0_b6f8859f-1320-44ab-b1ee-a3bcc428b823.jpg?v=1766114456"},{"product_id":"allen-bradley-1756-l55m23-controllogix-controller-and-memory-board","title":"Allen-Bradley 1756-L55M23 ControlLogix Controller and Memory Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1756-L55M23\u003c\/strong\u003e is a chassis-based central processing unit paired with a dedicated memory board assembly designed for the \u003cstrong\u003eControlLogix\u003c\/strong\u003e control platform. This device serves as the primary execution engine for industrial automation tasks, sequential control, motion control, and complex process application handling. Occupying a slot within any standard 1756 chassis, the \u003cstrong\u003e1756-L55M23\u003c\/strong\u003e features nonvolatile and volatile memory structures to maintain active user programs, tag databases, and operational logic configurations securely under demanding factory conditions.\u003c\/p\u003e\n\u003cp\u003eEquipped with an integrated front-facing communication interface, the controller provides point-to-point programming connectivity and simple network bridges directly to peripheral devices. The device coordinates system inputs and outputs via backplane interaction, executing high-capacity tasks with predictable scan cycles. Designed with a modular architecture, the memory board element is directly integrated to expand standard execution boundaries and ensure reliable data availability during complex processing routines.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Processing Architecture:\u003c\/strong\u003e Pairs a programmable automation controller with a dedicated memory board unit inside a unified single-slot form factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Front Programming Interface:\u003c\/strong\u003e Features a localized communication port for direct diagnostic linking, commissioning, and application program transfers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Versatility:\u003c\/strong\u003e Installs securely into any available slot of a standard ControlLogix chassis to simplify system configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Retention Mechanism:\u003c\/strong\u003e Built with a front latch assembly that aligns the module framework inside the backplane and prevents loose terminal coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed industrial automation and machinery synchronization control.\u003c\/li\u003e\n\u003cli\u003eSpecialized processing environments requiring stable logic execution and multi-task handling.\u003c\/li\u003e\n\u003cli\u003eReal-time monitoring and sequencing inside discrete factory automation networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-L55M23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix Controller and Memory Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis based, any slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Celsius to 60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to 85 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Port\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Serial Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect point-to-point programming, system diagnostics, and communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Protection:\u003c\/strong\u003e Touch a grounded object or wear an approved grounding wriststrap to discharge potential static electricity prior to touching the controller circuit board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Alignment:\u003c\/strong\u003e Align the circuit board with the top and bottom guides of the designated chassis slot and push firmly inward until the top and bottom tabs latch into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Component Security:\u003c\/strong\u003e Ensure the memory board assembly is seated correctly and locked on the processor board before inserting the controller housing into the rack backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Warnings:\u003c\/strong\u003e Verify that area power is completely disconnected or that the atmosphere is known to be non-hazardous prior to executing insertion or removal of the hardware.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695186899307,"sku":"1756-L55M23","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-l55m23-controllogix-controller-and-memory-board-a0giihthova_0c2f799e-18cd-41a6-a066-c3d53dbddd92.jpg?v=1766114489"},{"product_id":"allen-bradley-1756-lsp-guardlogix-5560-safety-partner-module","title":"Allen-Bradley 1756-LSP GuardLogix 5560 Safety Partner Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe \u003cstrong\u003eAllen-Bradley 1756-LSP\u003c\/strong\u003e serves as a dedicated, hardware-isolated redundant co-processor within safety-instrumented systems to execute multi-channel diagnostic and lockstep safety verification logic. Operating as a specialized \u003cstrong\u003esafety partner module\u003c\/strong\u003e paired with a primary controller, this unit establishes an isolated secondary execution environment to safely handle safety-related functions up to and including SIL 3 and Performance Level e requirements. The device contains no localized user memory for standard operations; instead, its configuration parameters, clock operations, and safety memory structures are bound to and managed by the corresponding master unit.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003e1-Slot Co-Processing Footprint\u003c\/strong\u003e: Occupies a single slot immediately adjacent to the primary controller, forming a two-slot processing pair within the chassis backplane.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDynamic Safety Memory Allocation\u003c\/strong\u003e: Safety allocation corresponds directly to the paired master unit, providing 1 MB when paired with 1756-L61S or 1756-L62S, and 3.75 MB when linked with a 1756-L63S.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh Connection Density\u003c\/strong\u003e: Manages up to 250 data connections for handling complex industrial safety interlock distributions.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eIntegrated Diagnostics\u003c\/strong\u003e: Built-in LED status indicators provide immediate local visual confirmation of execution states, errors, and sync conditions.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eNonvolatile Flash Backup\u003c\/strong\u003e: Ships complete with a pre-installed CompactFlash card to ensure secure storage of firmware images and operating parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eSIL 3 and Performance Level e (PL e) emergency shutdown loops in high-risk industrial fields.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eLockstep co-processing pairs within automated burner management systems (BMS) and pressing cells.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eFail-safe interlock handling in manufacturing setups requiring strict isolation from standard control logic execution paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1756-LSP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSafety Partner Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eGuardLogix 5560\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCompatible Primary Controllers\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1756-L61S, 1756-L62S, 1756-L63S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupported Connections\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e250\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eUser \/ Standard Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eN\/A (None)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Draw @ 5.1V DC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1200 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Draw @ 24V DC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e14 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Dissipation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3.5 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eThermal Dissipation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e11.9 BTU\/hr\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eIsolation Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e30V Continuous (Basic Insulation, Type-tested from RS-232 port-to-system at 720V DC for 60 seconds)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eLocal Serial Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 x RS-232 port\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eBackup Battery Element\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1756-BA2 (0.50 g lithium assembly)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eChassis Slot Width Allocation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 slot (Requires adjacent slot for primary module; 2 slots total for operation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eChassis Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Supply Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1756-PA50, 1756-PA72, 1756-PA75, 1756-PB50, 1756-PB72, 1756-PB75\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEnclosure Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eNone (Open-Style)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 Celsius to 60 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNon-Operating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 Celsius to 85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRelative Environmental Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5-95% non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMechanical Shock (Operating)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e30 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMechanical Shock (Non-Operating)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eVibration Stress Tolerance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 g at 10-500 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.75 lbs (0.34 kg)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePhysical Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e27 x 17 x 7 cm (10.63 x 6.69 x 2.76 in.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe 1756-LSP safety partner is structurally locked to the GuardLogix 5560 architecture. It functions solely when paired alongside a 1756-L61S, 1756-L62S, or 1756-L63S safety controller. Attempting to link this safety module with standard ControlLogix non-safety processors or newer ControlLogix 5570\/5580 systems will result in backplane verification errors and halt CPU configuration loading.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nA major engineering pitfall occurs when calculating available workspace inside open enclosures. If the safety partner is not placed in the slot directly to the right of its primary controller, the pair cannot satisfy structural SIL 3 requirements, causing a total breakdown of safety loop integrity. Furthermore, because this card relies completely on the master controller for communication links and configuration parameters, its onboard RS-232 port cannot be independently utilized for broad network mapping or logic modification. Ensure the onboard 1756-BA2 lithium battery cell is monitored regularly; low energy levels can corrupt clock operations during complete system power blackouts.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize and lock out all main backplane paths and external auxiliary supply voltages before mounting or extracting the co-processor hardware. Handling module installation steps while the rack contains active residual voltage risks triggering unexpected backplane noise spikes, communication drops on adjacent nodes, or component degradation.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eVerify the position of the primary master controller (1756-L61S, -L62S, or -L63S) within the selected standard 1756 chassis rack.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eClear the unmanaged slot situated immediately to the right of that primary unit to allow proper mechanical alignment for SIL 3 tracking.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eAlign the circuit card tracks of the safety partner module with the plastic guides of the intended empty slot.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSlide the unit smoothly backward into the slot until the upper and lower mechanical clips seat flush and snap lock onto the chassis rim.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; margin-top: 0.1rem;\"\u003e5\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eRestore power to the chassis and examine the forward LED cluster to confirm initialization and paired connection handshakes with the primary processor.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695187292523,"sku":"1756-LSP","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-lsp-guardlogix-safety-partner-controller-ueeyysveis5_b8540959-aad7-4845-86ae-96785c728f74.jpg?v=1766114503"},{"product_id":"allen-bradley-1771-ofe1-plc-5-analog-output-module","title":"Allen-Bradley 1771-OFE1 PLC-5 Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1771-OFE1\u003c\/strong\u003e is a 4-channel analog output module that converts digital values from a processor into analog voltage signals to control field devices within a industrial control network. This single-slot module interfaces directly into a Bulletin \u003cstrong\u003e1771\u003c\/strong\u003e I\/O chassis and operates with \u003cstrong\u003ePLC-5\u003c\/strong\u003e controllers via block transfer programming. The module converts 12-bit binary or 4-digit binary-coded decimal (BCD) values into high-resolution voltage outputs to regulate modulating infrastructure such as control valves, adjustable frequency AC drives, dampers, louvers, and positioners. It also acts as a precise signal source for data loggers, splitters, panel meters, totalizers, and single-loop controllers. Featuring 1500V optoelectrical isolation and 1000V individually-isolated differential outputs, the device secures processing equipment against localized overvoltage situations and contains dedicated internal short-circuit overload protection on each loop.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeamless operational configuration utilizing block transfer programming with Write Block Transfer instructions moving up to 13 data words and Read Block Transfer instructions carrying 5 debugging words.\u003c\/li\u003e\n\u003cli\u003eFour independent, 1000V individually-isolated differential voltage loops avoiding ground loops across widely separated field components.\u003c\/li\u003e\n\u003cli\u003eDual data format functionality supporting both Binary Coded Decimal (BCD) scaling and natural binary encoding to fit specific system setups.\u003c\/li\u003e\n\u003cli\u003eSelf-testing logic sequences executed automatically during startup to provide early operational diagnosis and system verification.\u003c\/li\u003e\n\u003cli\u003eBuilt-in overload protection circuits embedded on each separate channel path to safeguard hardware against load short circuits.\u003c\/li\u003e\n\u003cli\u003eShipped with a dedicated 1771-WH wiring arm allowing rapid module replacement without disconnecting active field wiring links.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProportional modulation of industrial control valves and dampening louvers.\u003c\/li\u003e\n\u003cli\u003eSpeed command reference transmission for adjustable frequency AC variable speed motor controllers.\u003c\/li\u003e\n\u003cli\u003eSignal sourcing for centralized data logging networks, splitters, and digital panel meters.\u003c\/li\u003e\n\u003cli\u003eDistributed control coupling with standalone single-loop controllers and processing totalizers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRevisions\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1771-OFE1 Ser A\u003c\/td\u003e\n\u003ctd\u003e1771-OFE1\/A, Series A, Rev A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1771-OFE1 Ser B\u003c\/td\u003e\n\u003ctd\u003e1771-OFE1\/B, Series B, Rev B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance and Electrical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line \/ Series\u003c\/td\u003e\n\u003ctd\u003ePLC-5 \/ PLC Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1771-OFE1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598003051\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003eFour (4) isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4 Isolated (1000 Volt) Differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Ranges\u003c\/td\u003e\n\u003ctd\u003e+1 to +5 VDC; -10 to +10 VDC; 0 to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDAC Converter Settling Time\u003c\/td\u003e\n\u003ctd\u003e0.8 ms (maximum for a resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Scan Rate (BCD with Scaling)\u003c\/td\u003e\n\u003ctd\u003e8.0 ms for every channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Scan Rate (Binary without Scaling)\u003c\/td\u003e\n\u003ctd\u003e1.6 ms for all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Accuracy (BCD Mode)\u003c\/td\u003e\n\u003ctd\u003e+0.1% of full scale; +1\/2 Least Significant Digit (LSD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Accuracy (Binary Mode)\u003c\/td\u003e\n\u003ctd\u003e+0.1% of full scale; +1\/2 Least Significant Bit (LSB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptoelectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Power Consumption\u003c\/td\u003e\n\u003ctd\u003e1.50 Amperes at 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired External Power\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e7.9 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Thermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e26.9 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical AC Signal Delay (Off)\u003c\/td\u003e\n\u003ctd\u003e45 (+\/- 15) ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical DC Signal Delay (Off)\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003e1771 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Arm\u003c\/td\u003e\n\u003ctd\u003e1771-WH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical and Environmental Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack Mountable (Single Slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25 lbs (0.57 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e32 to 140 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 185 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e2g at 10-500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all chassis backplane power before inserting or removing the module from its structural slot.\u003c\/li\u003e\n\u003cli\u003eSnap appropriate keying bands between positions 10-12 and 26-28 to dedicate the specific slot position for this module type.\u003c\/li\u003e\n\u003cli\u003eSlide the card firmly into the chassis card guides until it seats fully into the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eSecure all external loop wires to the 1771-WH wiring arm, ensuring correct polarity for each isolated channel.\u003c\/li\u003e\n\u003cli\u003eSum the backplane current draw (1.50 A) with all other modules to confirm the chassis power supply capacity is not exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695188963691,"sku":"Allen Bradley 1771-OFE1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1771-ofe1-analog-output-module-yzqqf23znpx_610b299b-5010-4ea7-8909-fb781bc04fd6.jpg?v=1766114560"},{"product_id":"allen-bradley-1756-l71s-guardlogix-5571s-safety-automation-controller","title":"Allen-Bradley 1756-L71S GuardLogix 5571S Safety Automation Controller","description":"\u003ch3\u003eProduct Operational Summary\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-628\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-628\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-628\"\u003e1756-L71S\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-628\"\u003e is an industrial functional safety automation controller belonging to the Allen-Bradley Bulletin 1756 GuardLogix 5570 family, engineered to fulfill the exact operational criteria of the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-628\"\u003eLogix 5571S Automation Controller 2\/1M\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-628 citation-end-628\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-627\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThis module delivers state-of-the-art dual-processor multitasking execution, purposefully built for safety-critical control application loops\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-627 citation-end-627\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-626\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eIt manages safety zones in high-risk processing environments—such as automotive robotic assembly cells, complex material handling lines, and chemical processing facilities—while concurrently running standard plant logic tasks\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-626 citation-end-626\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-625\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eBy providing decoupled execution tasks, it allows developers to execute discrete safety interlocking and standard machine automation routines simultaneously inside a single physical chassis slot\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-625 citation-end-625\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Architecture and Functional Design\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-624\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe hardware architecture of the 1756-L71S uses a 2-out-of-2 (2oo2) electronic voting structure\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-624 citation-end-624\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-623\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe standard ControlLogix processor executes primary machine control routines, while a dedicated Safety Partner module (such as the 1756-L7SP) acts as a co-processor to execute safety tasks and provide continuous diagnostic validation\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-623 citation-end-623\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-622\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-622\"\u003eFor its internal memory layout, the \"2\/1M\" designation corresponds directly to its calibrated volatile memory boundaries: it features \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-622\"\u003e2 MB of User Memory\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-622\"\u003e reserved exclusively for standard tasks, alongside \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-622\"\u003e1 MB of Safety Memory\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-622\"\u003e dedicated entirely to safety tasks\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-622 citation-end-622\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-621\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eProgrammatic execution constraints enforce that safety tasks support the Ladder Diagram (LD) programming language exclusively to ensure deterministic cross-checking, while standard logic tasks can be programmed across multiple languages, including Structured Text (ST), Function Block Diagram (FBD), and Sequential Function Charts (SFC)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-621 citation-end-621\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Metric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Technical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-620\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e1756-L71S\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-620 citation-end-620\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-619\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-619 citation-end-619\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-618\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eGuardLogix 5570 Automation Controllers\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-618 citation-end-618\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard User Memory Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-617\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e2 MB\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-617 citation-end-617\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Task Memory Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-616\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-616 citation-end-616\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Memory Allocation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-615\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e0.98 MB\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-615 citation-end-615\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Digital I\/O Capability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-614\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e128,000 nodes\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-614 citation-end-614\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Analog I\/O Capability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-613\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e4000 channels\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-613 citation-end-613\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNonvolatile Firmware Storage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-612\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e1 GB Secure Digital (SD) card (1784-SD1 pre-installed)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-612 citation-end-612\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw @ 5.1V DC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-611\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e800 mA\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-611 citation-end-611\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw @ 1.2V DC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-610\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e5 mA\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-610 citation-end-610\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Thermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-609\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e8.5 BTU\/hr\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-609 citation-end-609\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Power Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-608\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e2.5 W\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-608 citation-end-608\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage Stability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-607\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e30V continuous (Basic insulation type, USB port-to-system)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-607 citation-end-607\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Communication Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-606\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eEtherNet\/IP, ControlNet, DeviceNet\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-606 citation-end-606\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOnboard Programming Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-605\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eHigh-Speed USB 2.0 (Front-panel local access only)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-605 citation-end-605\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnergy Storage Module Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-604\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eRemovable Capacitor Modules (1756-ESMCAP, 1756-ESMNSE, 1756-ESMNRM)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-604 citation-end-604\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Slot Width Occupancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-603\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e1 Standard ControlLogix Chassis Slot\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-603 citation-end-603\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Envelope\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-602\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-602 citation-end-602\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-601\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eNone (Open-style module housing)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-601 citation-end-601\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat does the 2\/1M rating mean for programming a safety system?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-600\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe 2\/1M description defines the physically segregated memory allocations of the 1756-L71S module\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-600 citation-end-600\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-599\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe standard portion of your project file (such as non-safety HMI communication, diagnostic mappings, and sequencing code) can utilize up to 2 MB of user memory\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-599 citation-end-599\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-598\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe critical safety-related interlocking code (such as light curtains, emergency stops, and safe-speed control loops) is restricted to a separate 1 MB memory area\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-598 citation-end-598\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs the 1756-L71S controller capable of running safety routines independently without accessories?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNo, the 1756-L71S cannot execute safety tasks alone. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-597\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eIt must be paired with an adjacent 1756-L7SP (or 1756-L7SPK) Safety Partner module in the same local chassis\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-597 citation-end-597\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-596\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe Safety Partner acts as the secondary voting channel, checking the primary controller's safety logic processing to achieve functional safety certifications\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-596 citation-end-596\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHow are program backups preserved during an unexpected loss of backplane power?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-595\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe controller ships with an installed 1756-ESMCAP capacitor energy storage module\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-595 citation-end-595\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-594\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eWhen backplane power fails, this capacitor provides temporary internal power, allowing the processor to automatically flush the active project from its volatile RAM into the nonvolatile 1 GB SD card (1784-SD1)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-594 citation-end-594\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-593\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThis design eliminates the need for legacy lithium backup batteries\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-593 citation-end-593\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Safety Declarations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-592\"\u003eLocal Safety Partner Placement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-592\"\u003e When installing the 1756-L71S inside a 1756-A series backplane chassis, the mandatory 1756-L7SP safety partner must be placed in the slot immediately to the right of the primary controller\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-592 citation-end-592\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-591\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe two modules communicate over a high-speed local connection to maintain synchronous safety diagnostics\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-591 citation-end-591\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-590\"\u003eEnergy Storage Transport Safety:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-590\"\u003e If your facility requires the module to be completely depleted of electrical energy before removal or air transit, replace the standard 1756-ESMCAP module with a 1756-ESMNSE No-Stored-Energy module\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-590 citation-end-590\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-589\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe ESMNSE module drops its residual energy below 40 µJ in less than 40 seconds upon power disconnection\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-589 citation-end-589\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-588\"\u003eLocal Programming Port Restrictions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-588\"\u003e The front-facing USB 2.0 port is designed strictly for short-term maintenance tasks, such as initial firmware flashing, configuration changes, or uploading logic modifications\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-588 citation-end-588\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-587\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eIt is not rated or certified for permanent network connections, and it must not be connected while hazardous or explosive atmospheric conditions are present\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-587 citation-end-587\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695188996459,"sku":"1756-L71S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-l71s-guardlogix-integrated-safety-pac-module-kys0vrtaq4w_89ad3e3e-f814-4431-9051-8d22aad7871e.jpg?v=1766114561"},{"product_id":"allen-bradley-1756-pbr2-controllogix-redundant-power-supply-bundle-kit","title":"Allen-Bradley 1756-PBR2 ControlLogix Redundant Power Supply Bundle Kit","description":"\u003ch3\u003eFunctional Summary\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-PBR2 (1756PBR2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a complete, factory-bundled redundant DC power solution within the Allen-Bradley ControlLogix automation framework. Engineered for high-availability process lifelines in critical infrastructure operations such as offshore drilling platforms, municipal water treatment facilities, and continuously operating steel manufacturing systems, this bundle eliminates power delivery single points of failure. By pairing two hardware-independent redundant power supplies with a specialized chassis adapter, the system achieves a fault-tolerant architecture. If one incoming power feed drops or an internal component fault occurs, the secondary power supply immediately maintains full backplane current requirements without shifting system voltage states, preventing expensive processor resets and reducing catastrophic facility downtime.\u003c\/p\u003e\n\u003ch3\u003eSystem Kit Components and Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 1756-PBR2 redundant bundle includes a matched set of industrial hardware components configured to form a synchronized power network:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTwo 1756-PB75R Redundant Power Supplies:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThese 24 VDC nominal power modules feature advanced internal decoupling diodes to safely manage load-sharing tasks and shield the backplane rail against upstream line short-circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOne 1756-PSCA2 Chassis Adapter Module:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis passive hardware module mounts directly to the left side of any standard 1756 ControlLogix chassis, serving as the localized connection plane that channels currents from both external supplies directly to the backplane pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTwo 1756-CPR2 Redundancy Cables:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThese heavy-duty, low-impedance connection links transfer DC output currents and critical status signaling from the independent power enclosures directly to the 1756-PSCA2 chassis adapter interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe integrated control electronics feature limited line hold-up capabilities to ride out temporary input voltage drops, alongside an early-warning shutdown broadcast loop that informs all local I\/O and processor modules of an imminent voltage crash to ensure safe data persistence before power drops out completely.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Engineering Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Metric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Product Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-PBR2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Platform\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix (Bulletin 1756 \/ 1757)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Kit Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundant DC Power Supply Bundle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Supply Voltage (Nominal)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperational Input Voltage Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19 to 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Backplane Power Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 W @ 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBundle Bill of Materials\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 1756-PB75R Power Supplies, 1 x 1756-PSCA2 Chassis Adapter, 2 x 1756-CPR2 Redundancy Cables\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Status Diagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated LED health indicators with predictive power failure signaling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature (Min)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C (32 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 deg C (140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C (-40 to 185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity Boundaries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95 percent non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration Acceleration Limit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 m\/s sq maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration Frequency Threshold\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 Hz operational maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Rail Voltages Generated\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAll standard voltages necessary for standard ControlLogix module execution (1.2V, 3.3V, 5.1V, 24V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Protection Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen-style industrial hardware assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCombined Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.95 kg (6.50 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1756-PBR2 bundle allow true live-swapping of an individual power module during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because the 1756-PBR2 bundle places the power supplies on an external mounting panel detached from the chassis, you can safely swap out a faulty 1756-PB75R module or disconnect its 1756-CPR2 cable under live operating conditions. The surviving power supply maintains the full load requirement, ensuring zero disruption to the active processor tasks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the two 1756-PB75R units inside this bundle be powered from different 24 VDC source lines?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, this is the recommended field design for maximizing infrastructure uptime. Wiring one supply module to a dedicated 24 VDC battery bank and the second module to an independent utility-driven 24 VDC industrial power source ensures continuous operation even during a complete plant utility blackout.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the specific purpose of the 1756-PSCA2 module included in this kit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1756-PSCA2 is a passive routing adapter that occupies the standard left-hand power supply slot on a ControlLogix chassis. It contains no active internal conversion logic; instead, it provides the physical terminals for the two 1756-CPR2 redundancy cables, merging their independent output rails into a single backplane power feed.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering and Installation Protocol\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Adapter Mechanical Fastening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMount the 1756-PSCA2 adapter module securely onto the left-hand mounting pins of the standard ControlLogix chassis. Tighten the top and bottom captive hardware screws to lock the interface into place. Ensure the main chassis grounding lug uses a low-impedance copper strap tied directly to the enclosure ground bus bar to clear high-frequency noise from the incoming DC rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Cable Retention and Minimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the two 1756-CPR2 cables between the rear connectors of the 1756-PB75R supplies and the dual docking ports on the faceplate of the 1756-PSCA2 adapter. Secure all mechanical cable thumbscrews to protect against connection failure caused by field vibration. Do not bend the 1756-CPR2 cables past a minimum radius of 50 mm (2.0 inches) to prevent stress fatigue on the internal signaling strands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management and Clearance Layout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExternal 1756-PB75R power units rely on natural convection to vent thermal energy. Mount the supplies vertically on a backpanel or DIN-rail structure, keeping at least 51 mm (2.0 inches) of clear space above and below each housing. Route all 24 VDC field power source lines in independent wire ways away from data links and high-voltage motor conductors to insulate the power network from inductive noise spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695189520747,"sku":"Allen Bradley 1756-PBR2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-pbr2-redundant-power-supply-3l45pxgvwqf_eef23023-dc2c-484a-a98f-b41bbc61acfe.jpg?v=1766114579"},{"product_id":"allen-bradley-1756-rio-controllogix-remote-i-o-scanner-module","title":"Allen-Bradley 1756-RIO ControlLogix Remote I\/O Scanner Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1756-RIO (1756RIO)\u003c\/strong\u003e is a ControlLogix Remote I\/O scanner module developed by Allen-Bradley for bridging legacy Remote I\/O networks with modern Logix controllers. The module enables a ControlLogix chassis to act as a scanner on classic RIO networks, allowing migration without replacing installed field I\/O. It supports block transfer messaging, discrete data exchange, and rack addressing used in legacy PLC architectures. Engineers deploy this module in refineries, power generation facilities, and heavy material handling systems where phased upgrades reduce downtime. The 1756-RIO preserves installed infrastructure while enabling high-speed data exchange and deterministic control integration.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1756-RIO operates as a Remote I\/O scanner within the ControlLogix backplane. The module communicates with legacy I\/O adapters using blue hose Remote I\/O cabling and supports standard rack addressing modes. It manages block transfer read and write instructions for analog and intelligent devices. The hardware supports selectable baud rates and flexible rack size configuration. The module handles discrete input and output mapping directly into Logix memory. It also supports partial rack addressing, improving compatibility with mixed legacy installations. Backplane communication occurs through the ControlLogix chassis, eliminating external gateway hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-RIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eControlLogix Remote I\/O Scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e1.2 A at 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O Blue Hose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e57.6 kbps \/ 115.2 kbps \/ 230.4 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Addressing\u003c\/td\u003e\n\u003ctd\u003e1\/4, 1\/2, 3\/4, Full Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 32 racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e30 V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e145 x 35 x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan 1756-RIO replace a PLC-5 RIO scanner directly?\u003c\/strong\u003e\u003cbr\u003eYes. The module functions as a scanner and communicates with existing Remote I\/O adapters. Logix mapping must be configured.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support block transfer instructions?\u003c\/strong\u003e\u003cbr\u003eYes. The 1756-RIO supports block transfer read and write messaging for analog and intelligent I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable type is required for Remote I\/O communication?\u003c\/strong\u003e\u003cbr\u003eThe module uses standard Remote I\/O blue hose cable with daisy chain topology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 1756-RIO compatible with ControlLogix redundancy?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports redundancy when installed in mirrored chassis with identical configuration.\u003c\/p\u003e\n\u003ch3\u003eEngineering Installation Guide\u003c\/h3\u003e\n\u003ch4\u003eStep 1: Verify Chassis Power Budget\u003c\/h4\u003e\n\u003cp\u003eConfirm the ControlLogix power supply supports the 1756-RIO current requirement. The module draws backplane current from 5.1 VDC. Check total chassis load before installation to avoid power supply overload. High density racks may require higher capacity power supply.\u003c\/p\u003e\n\u003ch4\u003eStep 2: Select Proper Slot Location\u003c\/h4\u003e\n\u003cp\u003eInstall the 1756-RIO in a standard ControlLogix slot. Avoid placing the module next to high heat modules such as analog outputs or power supplies. Maintain airflow spacing inside the chassis for stable thermal performance.\u003c\/p\u003e\n\u003ch4\u003eStep 3: Configure Module Node and Baud Rate\u003c\/h4\u003e\n\u003cp\u003eSet the Remote I O baud rate to match existing adapters. Supported speeds include 57.6 kbps, 115.2 kbps, and 230.4 kbps. All devices on the Remote I O network must use identical communication speed.\u003c\/p\u003e\n\u003ch4\u003eStep 4: Prepare Remote I O Cable Wiring\u003c\/h4\u003e\n\u003cp\u003eUse approved blue hose Remote I O cable. Implement daisy chain topology only. Do not use star or ring wiring. Maintain consistent cable impedance across the trunk line.\u003c\/p\u003e\n\u003ch4\u003eStep 5: Install Network Termination\u003c\/h4\u003e\n\u003cp\u003eInstall termination resistors at both ends of the Remote I O trunk. Improper termination causes communication retries and rack faults. Verify termination before applying power.\u003c\/p\u003e\n\u003ch4\u003eStep 6: Configure Rack Addressing\u003c\/h4\u003e\n\u003cp\u003eMatch rack addressing with legacy Remote I O adapters. The 1756-RIO supports full rack, half rack, and quarter rack addressing. Incorrect configuration causes I O mapping errors.\u003c\/p\u003e\n\u003ch4\u003eStep 7: Grounding and Shielding\u003c\/h4\u003e\n\u003cp\u003eConnect cable shield to chassis ground at one point only. Avoid multiple ground connections. Route Remote I O cable away from motor drives and high voltage wiring.\u003c\/p\u003e\n\u003ch4\u003eStep 8: Insert Module into Chassis\u003c\/h4\u003e\n\u003cp\u003eInsert the 1756-RIO firmly into the backplane. Ensure top and bottom locking tabs engage fully. Loose seating may cause intermittent backplane communication faults.\u003c\/p\u003e\n\u003ch4\u003eStep 9: Power Up and Initial Diagnostics\u003c\/h4\u003e\n\u003cp\u003eApply power to the chassis. Check module status LED. Verify scanner enters run state. Monitor communication counters and rack status.\u003c\/p\u003e\n\u003ch4\u003eStep 10: Commissioning and Validation\u003c\/h4\u003e\n\u003cp\u003eDownload configuration from Studio 5000. Validate discrete mapping and block transfer messaging. Confirm all Remote I O racks update correctly. Monitor system for communication retries.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695189913963,"sku":"1756-RIO","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-rio-remote-i-o-network-module-yon3nuu21u5_96991a92-f27e-4265-a39a-dac5ac02950d.jpg?v=1766114592"},{"product_id":"allen-bradley-1756-en2tr-controllogix-ethernet-ip-dual-port-communication-module","title":"Allen-Bradley 1756-EN2TR ControlLogix EtherNet\/IP Dual Port Communication Module","description":"\u003ch3\u003eProduct Insights\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-EN2TR (1756EN2TR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, dual-port EtherNet\/IP communication module engineered for the Rockwell Automation ControlLogix platform. This module is indispensable for industrial sectors such as oil and gas refining, power generation, and automotive manufacturing, where network uptime is non-negotiable. By supporting Device Level Ring (DLR) topology, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-EN2TR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides hardware-layer redundancy that prevents system failure in the event of a single cable break. Its ability to manage high-speed I\/O data and explicit messaging simultaneously makes it the backbone of modern distributed control systems, significantly reducing unplanned downtime and enhancing plant-wide data transparency.\u003c\/p\u003e\n\u003ch3\u003eNetwork Architecture \u0026amp; Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-EN2TR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes standard EtherNet\/IP protocols to bridge the gap between high-level information systems and floor-level industrial assets.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Port Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike single-port modules, the dual RJ45 ports allow for flexible topologies, including linear and DLR, eliminating the need for external Ethernet switches in many configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Connection Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporting up to 256 CIP connections and 128 TCP connections, this module handles dense I\/O traffic and peer-to-peer interlocking with ease.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMessage Bridging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt facilitates seamless bridging of CIP unconnected messages (128 via backplane and 128 via Ethernet), ensuring that diagnostic and configuration data flow without bottlenecking real-time control traffic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features 30V continuous isolation and is type-tested at 980V AC to ensure electrical noise on the factory floor does not migrate to the ControlLogix backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eItem\u003c\/th\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-EN2TR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 x 30 x 145 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e5.1 V DC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 RJ45 (10\/100 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIP Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e30 V continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e2 G (10 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Rating\u003c\/td\u003e\n\u003ctd\u003e30 G operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standard\u003c\/td\u003e\n\u003ctd\u003eCISPR 11 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Knowledge Base\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1756-EN2TR support Ring Redundancy without an external switch?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module features integrated switching technology that specifically supports Device Level Ring (DLR) topology. This allows the module to be part of a resilient ring network where the hardware manages path recovery automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 1756-EN2T and the 1756-EN2TR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"R\" suffix in 1756-EN2TR stands for Redundancy\/Ring. While the 1756-EN2T has only one Ethernet port, the 1756-EN2TR has two ports and supports DLR and linear topologies directly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in hazardous locations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is rated with North American Temp Code T4A and ATEX\/IECEx Temp Code T4, making it suitable for specific hazardous environments when installed in a properly rated enclosure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDLR Implementation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen configuring a Device Level Ring, ensure that at least one node (typically a programmable controller or a specialized switch) is configured as the Ring Supervisor. While the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-EN2TR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis DLR-capable, the ring will not function as a redundant path without an active supervisor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse Category 5e (or higher) shielded twisted-pair (STP) cabling in high-interference environments to maintain 100 Mbps speeds. Ensure the drain wire is properly grounded at the chassis to mitigate EFT (Electrically Fast Transient) issues on the Ethernet ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn high-density chassis where multiple\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-EN2TR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules are used, maintain a minimum of 2 inches of clearance above and below the chassis. The module dissipates 17.4 BTU\/h, and stagnant air can lead to thermal throttling or premature component aging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUSB Port Usage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe front-facing USB port is intended for temporary local configuration and programming only. It is not designed for permanent connection or industrial networking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695190143339,"sku":"1756-EN2TR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-en2tr-controllogix-ethernet-ip-2fhuhn1yn52_da04789d-f8dc-42a5-a256-ec7a4bbbf565.jpg?v=1766114600"},{"product_id":"allen-bradley-1756-oa16-controllogix-16-point-ac-output-module","title":"Allen-Bradley 1756-OA16 ControlLogix 16-Point AC Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OA16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance discrete AC output module for the Allen-Bradley ControlLogix platform. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to interface with 120\/240V AC devices such as motor starters, solenoids, and indicators. The module utilizes TRIAC switching technology, which provides a reliable, solid-state solution for standard industrial AC loads.\u003c\/p\u003e\n\u003cp\u003eThe outputs are organized into two isolated groups of eight points each. This architecture allows the module to handle different AC phases or voltage sources within the same module, provided they stay within the 74…265V AC operating range. With built-in mechanical fusing and support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eScheduled Outputs\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OA16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust choice for time-critical AC control applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1756-OA16 is engineered for safety and precise AC switching:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Group Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 points are split into two groups of 8, with 250V continuous isolation between groups and from the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTRIAC Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmploys zero-crossing switching to minimize electrical noise and extend the life of connected AC components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach group is mechanically fused with a 3.15 A slow-blow fuse (Littelfuse p\/n H2153.15) to protect module circuitry from over-current conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBroad Voltage Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile nominally 120\/240V, it is specified to operate reliably from 74V to 265V AC at both 50 and 60 Hz frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable States:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsers can define how each point behaves during a PLC Fault or Program mode (Hold Last State, On, or Off).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-OA16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley (Rockwell Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (8 per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74…265V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent per Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A max @ 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent per Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 A max @ 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Delay (Off to On)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.3 ms @ 60 Hz \/ 11 ms @ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Current (Point)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A for 43 ms (repeatable every 2 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.15 A @ 250V (1 per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.17 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum load requirement for the 1756-OA16?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module requires a minimum load current of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper point to ensure the TRIAC stays latched. If you are driving a very high-impedance device (like a tiny neon lamp or high-end electronic relay), the output may not turn off correctly or could \"flicker\" due to leakage current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I do if my TRIAC output latches \"On\" with a small load?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor loads between 10…50 mA, the module has a lower commutating\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$dv\/dt$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003erating (\u003cspan class=\"math-inline\"\u003e$0.2V\/\\mu s$\u003c\/span\u003e). If the TRIAC latches on unexpectedly, you may need to add an external resistor across the output and L2 to increase the total current draw to at least 50 mA, which raises the rating to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$4V\/\\mu s$\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace the internal fuses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module uses mechanical fuses (Littelfuse p\/n H2153.15). However, if a fuse blows, it is critical to investigate the load for a short circuit before replacing it to prevent damage to the RTB or module.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Grouping\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Blocks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBNH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(NEMA screw) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBSH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Spring clamp) 20-pin removable terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommoning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGroup 0 (Points 0–7) and Group 1 (Points 8–15) have independent L1 and L2 connections. Do not mix DC power with this AC module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePilot Duty:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module is rated for 0.5 A pilot duty, making it suitable for controlling the coils of large motor starters (NEMA size 4 or smaller).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLeakage Current Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TRIAC outputs have a maximum off-state leakage current of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 mA\u003c\/strong\u003e. In systems with high-sensitivity inputs or very small loads, this leakage may be enough to keep a device energized. Always verify that your load's \"drop-out\" current is significantly higher than 3 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Crossing Switching\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module utilizes zero-crossing synchronization, meaning it waits for the AC sine wave to cross 0V before turning the output on or off. This significantly reduces Inrush Current and Electromagnetic Interference (EMI), which is vital for the longevity of the module and surrounding electronic equipment.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695190307179,"sku":"1756-OA16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-oa16-controllogix-discrete-output-module-jzpyw3o4hmr_045a7691-3768-4890-9e91-a8e0638b6e83.jpg?v=1766114605"},{"product_id":"allen-bradley-1756-ob32-controllogix-32-point-dc-output-module","title":"Allen-Bradley 1756-OB32 ControlLogix 32-Point DC Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OB32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density discrete output module for the Allen-Bradley ControlLogix platform. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 sourcing outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein a single-slot module, divided into two isolated groups of 16 points each. Operating within a 12\/24V DC range, this module is ideal for driving high-density solenoid valves, relays, and indicator lights in complex automation systems.\u003c\/p\u003e\n\u003cp\u003eEngineered for performance and reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OB32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures exceptionally fast response times (typically 60 µs from Off to On) and supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eScheduled Outputs\u003c\/strong\u003e, ensuring synchronized operation within the Coordinated System Time (CST) for time-critical manufacturing processes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1756-OB32 is designed for high-density control and environmental resilience:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Point Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 points per module allow for smaller chassis requirements and reduced cabinet footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGroup Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOutputs are arranged in two groups of 16, providing 125V continuous isolation between groups to protect against cross-talk or different power source issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures per-point fault mode states (Hold Last State, On, or Off), allowing for predictable machine behavior during a processor fault or program change.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module is rated for harsh environments, meeting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeverity Level G3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ISA 71.04) for corrosive atmospheres, making it suitable for wastewater, chemical, or heavy industrial sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Keying:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoftware-configurable keying ensures that the correct module type is present in the slot before the system allows operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-OB32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Sourcing (16 per group)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10…31.2V DC (24V DC Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent per Point\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A @ 50 °C \/ 0.35 A @ 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent per Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 A @ 50 °C \/ 10 A @ 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time (Off to On)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 µs nominal \/ 1 ms max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V (Outputs to Backplane) \/ 125V (Group to Group)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.8 W @ 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16.37 BTU\/hr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module have internal fusing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1756-OB32 is not internally fused. To protect your outputs from short circuits or over-current conditions, it is highly recommended to use a fused Interface Module (IFM) or external terminal block fuses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module to drive high-inrush loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports a surge current of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 A for 10 ms per point\u003c\/strong\u003e, repeatable every 2 seconds at 60 °C. If your load exceeds this (such as large DC motors), you should use an interposing relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Off-state leakage current\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum leakage current is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 mA per point\u003c\/strong\u003e. This is important to consider when driving high-impedance loads like small LEDs or sensitive electronic inputs, which might \"glow\" or stay active even when the output is technically Off.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Derating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen designing your panel, account for thermal derating. At\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 °C (122 °F)\u003c\/strong\u003e, the module can handle 0.5 A per point and 16 A total. However, at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e60 °C (140 °F)\u003c\/strong\u003e, the capacity drops to 0.35 A per point and 10 A total. Ensure your enclosure has adequate cooling to maintain these limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Termination\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Blocks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires a 36-pin Removable Terminal Block (RTB), specifically the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBCH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Cage clamp) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBSH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Spring clamp).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse 22–14 AWG solid or stranded copper wire rated for at least 105 °C. For double-wire connections, use 22–16 AWG.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommoning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach group of 16 points has its own DC+ (VDC) and DC- (COM) terminals. Ensure both groups are powered if all 32 points are in use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn Studio 5000:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault\/Program States:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigure how the outputs should react when the PLC enters \"Program Mode\" or if a communication \"Fault\" occurs. The default is \"Off,\" but \"Hold Last State\" is often used in continuous process applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Keying:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSet to \"Compatible Module\" for easier maintenance, or \"Exact Match\" for high-security applications where only a specific firmware\/series is allowed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695190438251,"sku":"Allen Bradley 1756-OB32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-ob32-controllogix-32-pt-12-24v-dc-d-o-module-sqqn2xnvqwo_7404ec45-77e4-4220-8ebf-3cfe69522330.jpg?v=1766114610"},{"product_id":"allen-bradley-1756-hsc-b-controllogix-high-speed-counter-module","title":"Allen-Bradley 1756-HSC\/B ControlLogix High-Speed Counter Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-HSC\/B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance High-Speed Counter (HSC) module designed for the Allen-Bradley ControlLogix platform. This module is engineered for precision motion and counting applications that exceed the scanning capabilities of standard digital input modules. It is capable of processing rapid pulse streams from encoders, flow meters, and proximity sensors with extreme accuracy.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeries B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion of this module offers refined stability and is an essential component for applications requiring high-speed event detection, such as bottling lines, material handling, and turbine speed monitoring. By offloading the counting logic from the CPU to the module hardware, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-HSC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that pulses are never \"missed\" due to PLC scan time fluctuations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1756-HSC provides robust I\/O capabilities tailored for industrial counting:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Counter Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures two independent counters, allowing for the simultaneous monitoring of two different high-speed processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTriple Input Per Counter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach counter accepts three inputs (typically A, B, and Z\/Index signals), facilitating full quadrature encoder support for directional and position sensing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuad Output Signals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes four physical outputs that can be configured to trigger based on specific count values (Preset\/Current Value), enabling real-time hardware-level responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to handle frequencies up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 MHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(in certain configurations), providing the resolution needed for high-speed manufacturing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDraws only 300 mA from the 5.1V backplane and a negligible 3 mA from the 24V source, resulting in a low total backplane power footprint of 1.6 Watts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-HSC (Series B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCounter Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInputs per Counter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 (A, B, and Z)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 mA @ 5.1V DC \/ 3 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Power Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.6 Watts @ 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.1 BTU\/hr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlot Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.23 kg (0.50 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between Series A and Series B?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile both series share the same core functional specs, Series B typically includes hardware revisions for improved component longevity and better resistance to electromagnetic interference (EMI). For most applications, Series B is preferred for its updated firmware compatibility and enhanced circuit protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module support a standard incremental encoder?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The three-input configuration per counter is specifically designed for incremental encoders. It supports X1, X2, and X4 quadrature decoding, as well as Up\/Down counting and Pulse\/Direction modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require an external power supply for the inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1756-HSC inputs and outputs require an external field power supply (typically 12\/24V DC). The backplane current listed is strictly for the module's internal logic and communication with the ControlLogix CPU.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Signal Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHigh-speed counting is highly sensitive to electrical noise. To prevent \"ghost counts\":\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse high-quality shielded twisted-pair cables for all encoder connections. Connect the shield to a single ground point at the chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNever route encoder cables in the same conduit or tray as high-voltage AC motor wires or VFD output cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the 1756-TBCH or 1756-TBSH (36-pin) removable terminal block is securely seated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eModule Configuration in Studio 5000\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen adding the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-HSC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto your I\/O tree:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilter Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigure the input filters to match your expected pulse frequency. Setting a filter too low will \"smooth out\" legitimate high-speed pulses, while setting it too high may allow noise to be counted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCounter Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSelect between \"Counter\" (for totalizing) or \"Encoder\" (for positioning).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the \"Storage\" feature to capture the current count value on a specific transition of the 'Z' input for precise homing sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1756-HSC dissipates up to 5.6 Watts. Ensure the ControlLogix chassis is mounted in a well-ventilated enclosure. If the cabinet's internal temperature approaches 60 °C, consider utilizing forced-air cooling to prevent thermal derating of the counting precision.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695190569323,"sku":"1756-HSC\/B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-hsc-b-hsc-module-ra4uewbbisd_8c782b85-0ecf-4a79-8a3b-67662f5047df.jpg?v=1766114611"},{"product_id":"1756-cn2r-allen-bradley-controllogix-controlnet-bridge-module","title":"1756-CN2R Allen-Bradley ControlLogix ControlNet Bridge Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-CN2R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance ControlNet bridge module belonging to the Allen-Bradley ControlLogix platform. It is specifically designed to facilitate high-speed, deterministic communication in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant network topologies\u003c\/strong\u003e. Featuring dual BNC ports, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-CN2R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for a \"bumpless\" switchover between media cables, ensuring that critical industrial processes remain online even if one network path is compromised.\u003c\/p\u003e\n\u003cp\u003eSupporting up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e99 nodes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a data rate of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 Mbps\u003c\/strong\u003e, this module is a cornerstone for Distributed I\/O architectures, HMI\/SCADA connectivity, and peer-to-peer controller interlocking. Its ability to cover up to 1,000 meters per segment (extendable via repeaters) makes it an ideal solution for large-scale manufacturing facilities and process plants that require time-critical data exchange via the Common Industrial Protocol (CIP).\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1756-CN2R is engineered for maximum availability and system flexibility:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Media Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual BNC ports provide two independent paths for ControlNet signals, protecting against cable breaks or connector failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Connection Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e128 Logix connections\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a total of 131 communication connections, allowing for extensive I\/O and messaging tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes a front-facing USB 1.1 port (12 Mbps) dedicated to local configuration, programming, and firmware updates (not intended for runtime data communication).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Environmentals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for a wide operating temperature range (0 to 60 °C) and high vibration resistance (2G at 10-500Hz), suitable for demanding cabinet environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with all standard 1756 ControlLogix chassis (A4 through A17) and both standard and redundant power supply configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-CN2R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlNet Bridge (Redundant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNodes (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e99\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogix Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e131\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1300 mA @ 5.1V DC \/ 3 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.7 Watts (22.9 BTU\/hr)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.51 x 4.41 x 5.71 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.43 kg (0.94 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable is required for the 1756-CN2R?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1786-RG6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003equad-shield RG6 coaxial cable. Proper termination with 75-ohm resistors at the ends of the trunk line is mandatory for network stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the USB port be used for HMI communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The USB port is strictly for temporary maintenance tasks, such as configuring the module via RSLinx or flashing firmware. Runtime data communication must occur over the ControlNet BNC ports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support \"Hot Swapping\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Like most 1756 modules, the 1756-CN2R supports Removal and Insertion Under Power (RIUP), allowing you to replace the module without cycling power to the entire chassis.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Cabling Strategy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo achieve true redundancy, route the two BNC coaxial cables (Channel A and Channel B) through different physical paths or conduits. This minimizes the risk of a single mechanical event (like a forklift accident or fire) severing both communication lines simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Scheduling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery ControlNet network containing a 1756-CN2R must be scheduled using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRSNetWorx for ControlNet\u003c\/strong\u003e. This software establishes the Network Update Time (NUT) and ensures that deterministic data (Scheduled) and non-critical data (Unscheduled) are prioritized correctly. Failing to \"save to the keeper\" after making hardware changes will result in I\/O communication failures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure the chassis is properly grounded to a low-impedance earth ground. The 1756-CN2R has an isolation voltage of 30V continuous, tested at 500V. Proper grounding is critical for the BNC shields to prevent electromagnetic interference (EMI) from corrupting the 5 Mbps data stream.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695190667627,"sku":"1756-CN2R","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-cn2r-controlnet-communication-module-0s3lkivwraf_0488d9b5-2aa6-4aa2-87ad-e441d7973b10.jpg?v=1766114615"},{"product_id":"allen-bradley-1769-if4xof2-compactlogix-analog-combination-module","title":"Allen-Bradley 1769-IF4XOF2 CompactLogix Analog Combination Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-IF4XOF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile analog I\/O combination module designed for the Allen-Bradley CompactLogix platform. By integrating both inputs and outputs into a single-slot width, this module provides a space-efficient solution for applications requiring a mix of analog signals, such as temperature control, pressure monitoring, and valve positioning.\u003c\/p\u003e\n\u003cp\u003eThe module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour analog inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(configurable as single-ended or differential) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo analog outputs\u003c\/strong\u003e. This hybrid design is particularly beneficial for smaller automation systems where cabinet space is limited, as it eliminates the need for separate input and output modules. With support for both voltage and current signals, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-IF4XOF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers the flexibility needed to interface with a wide variety of industrial sensors and actuators.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1769-IF4XOF2 is engineered for high reliability and ease of installation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Input Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4 inputs can be wired as single-ended for maximum density or differential to provide better noise immunity in electrically \"noisy\" environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Signal Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with standard industrial signals, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–20 mA, 4–20 mA, 0–10V DC, and ±10V DC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA front-facing green \"OK\" LED provides immediate visual confirmation of module health and backplane communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes built-in DIN rail latches and panel mounting tabs, allowing for secure installation in various enclosure types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDraws a modest 120 mA at 5V DC and 160 mA at 24V DC from the backplane, helping to stay within the power budget of the CompactLogix power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1769-IF4XOF2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Combination (Input\/Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (Single-ended or Differential)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 (Single-ended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10V, 0-10V, 0-5V, 1-5V, 0-20mA, 4-20mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10V, 0-10V, 0-5V, 1-5V, 0-20mA, 4-20mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Distance Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e118 x 35 x 87 mm (approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.43 kg (0.94 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix voltage and current signals on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each channel on the 1769-IF4XOF2 is individually configurable in the programming software (Studio 5000 or RSLogix 5000). You can have a pressure sensor using 4-20 mA on Channel 0 and a potentiometer using 0-10V on Channel 1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Power Supply Distance Rating\" of 8?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis rating indicates that the module must be located within 8 slots of a 1769 power supply. Placing it further away can result in insufficient voltage levels due to bus resistance, leading to intermittent communication or inaccurate analog readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of using Differential inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDifferential wiring uses two signal leads (plus a shield) and is highly effective at rejecting \"common-mode noise.\" If your sensor cables run near high-voltage motor wires or VFDs, differential wiring is the best way to ensure a stable, jitter-free signal.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Signal Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo ensure the highest accuracy, always use shielded twisted-pair cables for analog signals. Connect the shield to a single ground point (typically at the PLC chassis) to prevent ground loops. Avoid routing these low-voltage signal cables in the same conduit as high-power AC lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModule Placement and Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen calculating your system's power budget, remember that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-IF4XOF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edraws current from both the 5V and 24V DC buses. Ensure your 1769-PA2, PB2, or PA4 power supply has sufficient capacity to support this module along with any others in the bank.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn your controller's I\/O configuration tree:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAdd the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-IF4XOF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the appropriate slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigure the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInput Filter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., 60 Hz) to match your local power frequency to help reject electrical hum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSet the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eReal-Time Sampling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterval to balance the need for fast data with CPU overhead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDefine the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eScaling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., 4-20 mA = 0-100 psi) within the module tags for easier programming.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695190864235,"sku":"1769-IF4XOF2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1769-if4xof2-analog-i-o-module-3nquvodlung_e756514b-b266-420e-974c-b0084a3306cd.jpg?v=1766114624"},{"product_id":"1756-pb72-allen-bradley-controllogix-24v-dc-power-supply","title":"1756-PB72 Allen-Bradley ControlLogix 24V DC Power Supply","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003e1756-PB72\u003c\/span\u003e is a high-performance \u003cspan\u003e24V DC Power Supply\u003c\/span\u003e designed for the Allen-Bradley \u003cspan\u003eControlLogix 1756\u003c\/span\u003e chassis system. This module is responsible for converting an external 24V DC source into the specific backplane voltages (1.2V, 3.3V, 5.1V, and 24V DC) required to power ControlLogix processors, I\/O modules, and communication adapters. Engineered for maximum reliability in industrial environments, the \u003cspan\u003e1756-PB72\u003c\/span\u003e provides enhanced ride-through capabilities and robust protection against electrical transients, ensuring stable operation for critical control architectures.\u003c\/p\u003e\n\u003ch3\u003eFunctional Engineering \u0026amp; Load Capacity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003e1756-PB72\u003c\/span\u003e is designed to support high-density chassis configurations. It provides a total current capacity of \u003cspan\u003e13 Amps at 5.1V DC\u003c\/span\u003e and \u003cspan\u003e2.8 Amps at 24V DC\u003c\/span\u003e to the backplane. Its \"slim\" yet powerful design allows it to be mounted on the left side of any standard 1756 chassis (4, 7, 10, 13, or 17-slot), efficiently distributing power across the entire backplane. The module features integrated circuit protection and a front-panel status LED, allowing maintenance teams to instantly verify the health of the DC input and internal conversion logic.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-PB72\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18–32V DC (24V DC Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Power (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Power (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Watts @ 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current (5.1V)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current (24V)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.8 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInrush Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 Amps (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C (32 °F to +140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V (Continuous), Reinforced Insulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140 x 112 x 145 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the \"Hold-up Time\" for the 1756-PB72?\u003c\/span\u003eThe module is designed with a hold-up time of approximately \u003cspan\u003e35ms @ 24V DC\u003c\/span\u003e. This ensures that the ControlLogix processor can perform an orderly shutdown or \"ride through\" momentary power sags and micro-interruptions without causing a system fault or losing volatile data.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan I use the 1756-PB72 in a redundant power configuration?\u003c\/span\u003eNo. The \u003cspan\u003e1756-PB72\u003c\/span\u003e is a standard power supply. For redundancy, you would require the \u003cspan\u003e1756-PB72R\u003c\/span\u003e (Redundant) power supply along with a \u003cspan\u003e1756-CPR2\u003c\/span\u003e cable and a \u003cspan\u003e1756-PSCA2\u003c\/span\u003e chassis adapter. The standard PB72 is intended for single-supply applications where high amperage is required but physical redundancy is not a project mandate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHow do I calculate if the 1756-PB72 is sufficient for my chassis?\u003c\/span\u003eYou must sum the backplane current requirements (at 5.1V and 24V) for every module in your chassis. If the total exceeds 13A at 5.1V or 2.8A at 24V, the system may experience intermittent resets. Rockwell Automation’s \u003cspan\u003eIntegrated Architecture Builder (IAB)\u003c\/span\u003e is the recommended tool for performing these power budget calculations accurately.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWiring Requirements:\u003c\/span\u003e Use a minimum of \u003cspan\u003e14 AWG (2.5 mm²)\u003c\/span\u003e solid or stranded copper wire rated for at least 75°C for the DC input connections. Ensure the 24V DC source is properly fused or protected by a circuit breaker to prevent damage during a sustained overcurrent event.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eChassis Attachment:\u003c\/span\u003e The power supply mounts to the left end of the 1756 chassis. Ensure the two chassis mounting screws are tightened to the specified torque (\u003cspan\u003e1.16 N•m\u003c\/span\u003e) to maintain a solid ground connection, which is vital for the module's internal EMI filtering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironmental Clearance:\u003c\/span\u003e Maintain a minimum of \u003cspan\u003e2 inches (50 mm)\u003c\/span\u003e of clearance above and below the power supply for airflow. Excessive heat is the primary cause of power supply failure; ensuring proper convection cooling will significantly extend the life of the internal electrolytic capacitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003e1756-PB72\u003c\/span\u003e offers a robust and space-efficient power solution for DC-powered control cabinets. Its high isolation rating (\u003cspan\u003e250V continuous\u003c\/span\u003e) ensures that field-side electrical noise and ground loops do not reach the sensitive backplane electronics. For B2B procurement, choosing the original \u003cspan\u003eAllen-Bradley 1756-PB72\u003c\/span\u003e ensures full compatibility with the 1756 chassis series and maintains the system's UL, CSA, and CE certifications, providing a reliable foundation for any ControlLogix-based automation project.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695191159147,"sku":"1756-PB72","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-pb72-controllogix-power-supply-s0s0q1qlgv1_71592750-ece1-4854-b42d-e49c0a12ed1d.jpg?v=1766114634"},{"product_id":"allen-bradley-1756-l55m13-controllogix-555-processor-module","title":"Allen Bradley 1756-L55M13 ControlLogix 555 Processor Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003e1756-L55M13\u003c\/span\u003e is a Series A \u003cspan\u003eControlLogix 5555 Controller\u003c\/span\u003e engineered for high-performance discrete and process control within the Allen-Bradley 1756 chassis system. Featuring \u003cspan\u003e1.5 MB of logic and data memory\u003c\/span\u003e and an additional \u003cspan\u003e208 KB of dedicated I\/O memory\u003c\/span\u003e, this processor is designed to manage complex automation architectures with up to \u003cspan\u003e128,000 digital I\/O points\u003c\/span\u003e. With a rapid program scan time of \u003cspan\u003e0.08 milliseconds\u003c\/span\u003e, the 1756-L55M13 provides the processing power necessary for high-speed motion control and synchronized multi-axis applications.\u003c\/p\u003e\n\u003ch3\u003eFunctional Intelligence \u0026amp; Networking\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003e1756-L55M13\u003c\/span\u003e acts as a versatile communication hub, supporting a wide array of network protocols including \u003cspan\u003eEtherNet\/IP, ControlNet, and DeviceNet\u003c\/span\u003e. It also facilitates legacy integration through Data Highway Plus (DH+) and Universal Remote I\/O. For high-speed controller-to-controller synchronization, it utilizes \u003cspan\u003eSynchLink\u003c\/span\u003e, ensuring precise data alignment across distributed systems. While this model does not feature integrated nonvolatile memory, it is fully compatible with \u003cspan\u003eredundant controller systems\u003c\/span\u003e, provided both processors reside within the same ControlNet network to maintain seamless failover state-tracking.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-L55M13\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix 5555\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser Memory (RAM)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208 KB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Digital I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128,000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4,000 Input \/ 2,000 Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScan Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.08 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.23 A @ 5.1V DC \/ 14 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Dissipation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.6 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C (32 °F to +140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-BA1 or 1756-BATM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan class=\"mat-mdc-button-persistent-ripple mdc-button__ripple\"\u003e\u003c\/span\u003e\u003cspan class=\"mdc-button__label\"\u003e\u003cspan class=\"export-sheets-button\"\u003e\u003cspan class=\"export-sheets-icon\"\u003e\u003c\/span\u003e\u003cspan\u003e导出到 Google 表格\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mat-focus-indicator\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-mdc-button-touch-target\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-mdc-button-persistent-ripple mdc-icon-button__ripple\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-focus-indicator\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-mdc-button-touch-target\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eHow should the memory be managed in the 1756-L55M13?\u003c\/span\u003eThe controller utilizes a split memory architecture: 1.5 MB for data and logic and a separate 208 KB for I\/O. Because the \u003cspan\u003e1756-L55M13\u003c\/span\u003e lacks internal nonvolatile memory (like an onboard Flash), it is critical to ensure the \u003cspan\u003e1756-BA1\u003c\/span\u003e lithium battery is healthy to prevent program loss during power cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhat cables are required for programming and configuration?\u003c\/span\u003eFor local serial communication and programming, the module is compatible with either the \u003cspan\u003e1756-CP3\u003c\/span\u003e or \u003cspan\u003e1747-CP3\u003c\/span\u003e cables. These connect directly to the front-facing RS-232 port, allowing for firmware updates and ladder logic modifications via Studio 5000 or RSLogix 5000 software.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the significance of the 707V DC isolation test?\u003c\/span\u003eThe module has been tested to withstand \u003cspan\u003e707V DC for 60 seconds\u003c\/span\u003e, ensuring high dielectric strength between the communication ports and the backplane. This protects the CPU from potential ground loops or electrical surges originating from field-side communications, which is vital for maintaining system uptime in heavy industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eChassis Placement:\u003c\/span\u003e The \u003cspan\u003e1756-L55M13\u003c\/span\u003e can be placed in any slot of a ControlLogix chassis, though Slot 0 is common for primary controllers. Ensure the chassis power supply (e.g., 1756-PA72) can support the \u003cspan\u003e1.23 A\u003c\/span\u003e current draw at 5V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundancy Setup:\u003c\/span\u003e When configuring for redundancy, both 1756-L55M13 modules must have identical firmware revisions and be linked via 1756-RM redundancy modules. The \"Located in the same ControlNet network\" rule is essential for the Nut (Network Update Time) synchronization required for bumpless transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironmental Shielding:\u003c\/span\u003e As an open-style controller, the \u003cspan\u003e1756-L55M13\u003c\/span\u003e must be housed in an enclosure that provides protection against conductive contaminants. It is rated for \u003cspan\u003e2 g of vibration\u003c\/span\u003e at 10-500 Hz, making it suitable for mounting on machinery frames when protected from direct moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003e1756-L55M13\u003c\/span\u003e provides a proven, scalable foundation for mid-to-large scale automation. Its ability to handle massive I\/O counts while maintaining sub-millisecond scan times makes it a preferred choice for complex assembly lines and material handling systems. For B2B procurement, sourcing an original \u003cspan\u003eAllen-Bradley 1756-L55M13\u003c\/span\u003e ensures full compliance with UL, CSA, and CE safety standards, providing the reliability and long-term support necessary for critical infrastructure and high-value manufacturing processes.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695191355755,"sku":"1756-L55M13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-l55m13-controller-processor-0ex54jujryc_17e2f8ec-36d8-4c81-9385-f1945a396b7e.jpg?v=1766114641"},{"product_id":"1756-l950tpsxt-allen-bradley-controllogix-5590-process-xt-controller","title":"1756-L950TPSXT Allen-Bradley ControlLogix 5590 Process XT Controller","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview and Extreme Environment Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L950TPSXT (1756L950TPSXT)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a flagship, high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix 5590\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtroller specifically engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProcess XT (Extended Temperature)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironment. This \"Extreme\" version of the L9 series is designed to thrive in harsh conditions where standard controllers fail, offering a temperature range from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-25 to +70 °C\u003c\/strong\u003e. Featuring a massive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 MB of user memory\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L950TPSXT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the definitive choice for large-scale process automation, such as offshore oil platforms, remote pipeline monitoring, and heavy chemical refineries. It integrates advanced security features and high-speed embedded Ethernet (1 Gbps) to manage the most data-intensive process control tasks with mission-critical reliability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Architecture and Process Intelligence\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L950TPSXT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built on the latest Logix engine, providing significant performance leaps over previous generations in both execution speed and communication throughput.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes factory-applied conformal coating as standard to protect internal circuitry against moisture, dust, and corrosive chemical atmospheres (Class G3 environment protection).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGigabit Ethernet Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a front-facing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 Gbps EtherNet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eport, supporting high-speed device integration, DLR (Device Level Ring) topologies, and high-capacity data producer\/consumer models.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMassive 50 MB Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides the largest memory capacity in its class, allowing for extensive historical data buffering, complex process sequencing, and the storage of large Asset Management (DTM) profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Storage Module (ESM):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEliminates the need for lithium batteries. The controller uses an internal capacitor-based ESM to safely write volatile RAM to non-volatile flash memory during a power loss event.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1756-L950TPSXT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley \/ Rockwell Automation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50 MB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-25 to +70 Celsius\u003c\/strong\u003e (Extreme Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Gbps Embedded Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax EtherNet\/IP Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnergy Storage Module (No Battery Required)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Signatures, Encrypted Firmware, Role-Based Access\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConformal Coating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1.2 kg\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eIntegrated Technical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the specific benefit of the \"Process\" (P) designation in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"Process\" designation signifies that the controller is optimized for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePlantPAx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control system. It includes instructions and internal logic specifically tuned for process industries, such as advanced PID control, alarm management, and simplified integration with process fieldbus devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"XT\" version differ from the standard L95?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eXT (Extended Temperature)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion uses specialized components and a robust mechanical design to expand the operating window. While a standard L95 is rated for 0–60 °C, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL950TPSXT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles -25–70 °C, making it suitable for unconditioned cabinets in extreme climates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the USB port for continuous communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUSB 2.0 port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis intended for temporary use, such as local programming, configuration, and firmware updates. For continuous high-speed data exchange with HMIs or other PLCs, the 1 Gbps Ethernet port should always be used.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Protocols\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEven though the module is rated for 70 °C, it is critical to ensure proper spacing in the 1756 chassis. Maintain at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2 in.)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance around the chassis to allow for natural convection, especially if using a high-density XT power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Lifecycle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven the security-hardened nature of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL9\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries, ensure the controller is flashed with the latest \"Signed\" firmware revision. This prevents the execution of unauthorized code and protects the system from firmware-level cyber threats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosive Environment Care:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile conformally coated, the external pins of the backplane and the Ethernet jack are still metallic. In highly corrosive environments, the use of a sealed, pressurized enclosure (NEMA 4X) is recommended to prevent connector oxidation over long periods.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L950TPSXT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epinnacle of process reliability\u003c\/strong\u003e. By combining \"Extreme\" hardware durability with \"Process\" optimized software instructions, it reduces the complexity of designing large-scale control systems for hazardous or remote locations. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 Gbps communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapability ensures that even as the \"Industrial Internet of Things\" (IIoT) adds more sensors and data points to the network, the controller will not become a bottleneck. This is the ideal controller for users migrating from legacy DCS systems to a modern, high-performance Logix environment that must operate in the most unforgiving conditions on Earth.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695191519595,"sku":"1756-L950TPSXT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-l950tpsxt-controllogix-5590-process-xt-controller-vwfjagmrovi_a3ca4c56-cc01-4403-95f5-416b01ab6fbb.jpg?v=1766114647"},{"product_id":"1768-pa3-allen-bradley-compactlogix-120-240v-ac-power-supply","title":"1768-PA3 Allen-Bradley CompactLogix 120\/240V AC Power Supply","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview and System Power Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3 (1768PA3)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency AC input power supply specifically designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-L43 and 1768-L45 CompactLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrollers. As part of the 1768-series architecture, this module provides the essential regulated DC voltages required to power the controller, the 1768 backplane, and any attached 1768 communication modules (such as the 1768-ENBT or 1768-CNB). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to handle the higher power demands of the 1768-series, which supports integrated motion and high-performance networking, making it a critical foundation for mid-range automation systems in conveyor control, assembly lines, and specialized process skids.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Architecture and Electrical Logic\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emounts directly to the left side of the 1768 controller. It converts standard industrial AC line power into the precise DC rails needed for internal logic and communication circuitry.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal AC Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports a wide input range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e85–265V AC\u003c\/strong\u003e, allowing for global deployment in both 110V and 220V power systems without the need for external transformers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed to provide sufficient current for up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo 1768-series communication or motion modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealongside the main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegulated Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a stabilized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5V DC and 24V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebackplane output, ensuring that voltage fluctuations on the factory floor do not affect the deterministic performance of the PLC logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Status Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a front-panel \"DC OK\" LED that provides immediate visual confirmation that the supply is outputting the correct voltages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley \/ Rockwell Automation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120V AC \/ 240V AC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47–63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Power (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32.5 W @ 5V DC; 28 W @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Power Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e60.5 W\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 A (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1.2 kg\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eIntegrated Technical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1768-PA3 with 1769-L3x controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis physically and electrically designed only for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-L43 and 1768-L45\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrollers. 1769-series controllers use 1769-PA2 or PA4 power supplies, which have a different form factor and backplane connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes the \"DC OK\" LED to turn off?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlit LED typically indicates one of three things: a loss of AC input power, an internal fuse failure, or an over-current condition on the backplane (often caused by a faulted communication module). Always measure the input terminals first to confirm line power is present.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide power for the field I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epowers the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtroller and the 1768-series modules only\u003c\/strong\u003e. If you have 1769-series I\/O modules attached to the right side of the controller, those I\/O modules may require their own 1769-series power supply (like a 1769-PA2) depending on the total current draw.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Protocols\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse a minimum of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e14 AWG (2.1 mm²)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewire for AC input connections. Ensure the \"Ground\" terminal is connected to a clean, low-impedance earth ground to help filter out electrical noise and protect against surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edissipates heat through convection. Maintain a minimum of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2 in.)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance above and below the module. If the module is installed in a small, unventilated enclosure, the internal thermal protection may trip, causing the PLC to shut down.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFinger-Safe Terminals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe terminal block features a protective cover. Always keep this cover closed during operation to prevent accidental contact with high-voltage AC terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust power-to-footprint ratio\u003c\/strong\u003e. It is built to support the high-speed data processing and motion synchronization required by the 1768-L4x series, which was a pioneer in bringing high-end Logix performance to a compact form factor. Its ability to bridge the gap between heavy-duty industrial power and sensitive micro-electronics makes it a reliable choice for \"Workhorse\" applications in the packaging and material handling industries where power quality may be inconsistent.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695191617899,"sku":"1768-PA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1768-pa3-compactlogix-power-supplies-v4fofautowh_273d2c06-390c-4de3-ae56-5d41e0de6646.jpg?v=1766114652"},{"product_id":"1756-of8-allen-bradley-controllogix-8-channel-analog-output-module","title":"1756-OF8 Allen-Bradley ControlLogix 8-Channel Analog Output Module","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview and Precision Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OF8 (1756OF8)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, versatile\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAnalog Output Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebelonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 non-isolated channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapable of delivering high-precision voltage or current signals to field devices. Designed for demanding applications such as variable frequency drive (VFD) speed control, valve positioning, and actuator modulation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers sub-millisecond updates and high-resolution digital-to-analog conversion. This module is a cornerstone for closed-loop process control, allowing for seamless integration of analog field equipment into the Logix Integrated Architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Architecture and Signal Flexibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoccupies a single slot in any 1756 ControlLogix chassis and interfaces with the processor via the high-speed backplane.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelectable Output Modes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 8 channels can be individually configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVoltage (+\/- 10V)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCurrent (0 to 20 mA or 4 to 20 mA)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e15-bit resolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross all ranges (approx. 320 uV per count for voltage and 0.65 uA per count for current), providing the granularity needed for sensitive flow or pressure control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Update Rates:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOffers a RPI (Requested Packet Interval) as low as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 ms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor all 8 channels, ensuring that control commands are executed with minimal latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes hardware features for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOpen Wire Detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(in current mode) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e, providing real-time feedback to the controller regarding field-side health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1756-OF8\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley \/ Rockwell Automation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Non-isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA \/ 4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15-bit (plus sign)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current (5V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current (24V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Settling Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 2 ms (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1.0 kg\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eIntegrated Technical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1756-OF8 provide channel-to-channel isolation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enon-isolated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule, meaning all 8 channels share a common return. If your application requires independent grounding for each signal (to prevent ground loops between different drives), you should utilize the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OF8I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Isolated) module instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the outputs if the PLC enters a Fault state or is switched to Program mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features configurable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"Program Mode\" and \"Fault Mode\" behaviors\u003c\/strong\u003e. Within the Studio 5000 software, you can choose to have each output hold its last value, switch to a specific safe state (e.g., 4 mA), or go to the minimum\/maximum of its range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I calibrate the 1756-OF8 in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield calibration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough the software. Using a high-precision voltmeter or ammeter, you can adjust the offset and gain parameters for each channel to account for environmental factors or long cable runs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Protocols\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Arm Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBNH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(20-pin) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBSH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Spring clamp) Removable Terminal Block (RTB). Always ensure the RTB is fully seated and the locking tab is engaged before applying field power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Loop Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen operating in current mode (4-20 mA), ensure the total loop impedance (wire resistance plus the load) does not exceed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e550 Ohms\u003c\/strong\u003e. Exceeding this limit will prevent the module from reaching the full 20 mA output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Strategy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor high-resolution analog control, use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshielded twisted-pair (STP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecables. Terminate the shield at the ground bar of the ControlLogix chassis. Avoid grounding the shield at the field device end to prevent ground loops that introduce signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControl System Density\u003c\/strong\u003e. By providing 8 channels in a single slot, it reduces the total chassis footprint and hardware costs for systems with high analog counts. Its ability to perform\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDigital-to-Analog conversion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elocally on the module allows the main processor to focus on high-level logic, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-OF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles the precise electrical ramp-up and ramp-down of signals. This makes it an ideal choice for the chemical, food and beverage, and power generation industries, where reliability and precise modulation of process variables are non-negotiable.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695191650667,"sku":"Allen Bradley 1756-OF8","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-of8-controllogix-8-pt-a-o-i-or-v-module-etawkyw3sxm_f87e85f3-4474-41e8-a6dd-ecaa3415a39a.jpg?v=1766114654"}],"url":"https:\/\/www.plcprotech.com\/bg\/collections\/plc-pac-systems.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}