{"title":"Weidmuller PRO Power","description":"  \u003cstrong\u003eWeidmuller PRO Power\u003c\/strong\u003e systems provide high-performance energy management for demanding industrial environments. This collection features the flagship \u003cstrong\u003ePROtop\u003c\/strong\u003e series with integrated DCL technology for superior peak power, the robust \u003cstrong\u003ePROmax\u003c\/strong\u003e designed for high-performance machine building, and the cost-effective \u003cstrong\u003ePROeco\u003c\/strong\u003e for basic automation tasks. With universal inputs, advanced diagnostics, and parallel connection capabilities, these DIN-rail power supplies ensure maximum uptime and energy efficiency for PLC systems, sensors, and critical control loads.\n","products":[{"product_id":"weidmuller-1469480000-pro-eco-120w-24v-5a-switch-mode-power-supply-unit","title":"Weidmuller 1469480000 PRO ECO 120W 24V 5A Switch-Mode Power Supply Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for reliable and space-saving power delivery in decentralized automation systems, the \u003cstrong\u003eWeidmuller 1469480000\u003c\/strong\u003e is a high-efficiency \u003cstrong\u003eswitch-mode power supply unit\u003c\/strong\u003e. Part of the robust PRO ECO series, this module delivers a regulated 24 V DC output at 5 A, providing a continuous 120 W of power. It features a wide-range input capable of accepting both AC and DC voltages, making it highly versatile for global industrial applications.\u003c\/p\u003e\n\n\u003cp\u003eThe unit is housed in a corrosion-resistant metal enclosure designed for TS 35 DIN rail mounting. It features an integrated potentiometer for output voltage adjustment, comprehensive diagnostic LEDs, and a floating status relay contact for remote monitoring. With built-in protection against overloads, short circuits, and over-temperature conditions, this power supply ensures high operational safety and system uptime in demanding environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh operational efficiency of 87% to minimize thermal losses inside control cabinets.\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range supporting 85 to 264 V AC and 80 to 370 V DC.\u003c\/li\u003e\n  \u003cli\u003eAdjustable output voltage from 22 to 28 V DC via a front-panel potentiometer.\u003c\/li\u003e\n  \u003cli\u003eTricolor LED diagnostics for real-time status indication (Green, Yellow, Red).\u003c\/li\u003e\n  \u003cli\u003eIntegrated floating relay contact for remote monitoring of output status.\u003c\/li\u003e\n  \u003cli\u003eRobust, corrosion-resistant metal housing with a compact 40 mm width.\u003c\/li\u003e\n  \u003cli\u003eSupport for parallel connection of up to 5 units to increase power capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation and control cabinet assembly.\u003c\/li\u003e\n  \u003cli\u003eMachine building and precision factory automation.\u003c\/li\u003e\n  \u003cli\u003eProcess engineering and water treatment facilities.\u003c\/li\u003e\n  \u003cli\u003ePower distribution networks and wind energy systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1469480000 (PRO ECO 120W 24V 5A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range (AC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85...264 V AC (derating at 100 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range (DC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80...370 V DC (derating at 120 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e47...63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.26 A @ 230 V AC \/ 2.24 A @ 110 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.39 A @ 370 V DC \/ 1.16 A @ 120 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003emax. 40 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC +\/- 1 %\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e22...28 V DC (adjustable via potentiometer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 A @ 55 degC, 3.75 A @ 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResidual Ripple \/ Breaking Spikes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eless than 50 mVPP @ 24 V DC, IN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Failure Bridging Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003egreater than 80 ms @ 230 V AC \/ greater than 20 ms @ 115 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e87%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Loss (Idling \/ Nominal Load)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 W \/ 15 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGreen LED (Uout \u0026gt; 21.6 V DC), Yellow LED (Iout \u0026gt; 90% nominal), Red LED (overload, overtemperature, short-circuit, Uout \u0026lt; 20.4 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFloating Contact \/ Relay\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes (max. 30 V DC \/ 1 A), active when Uout \u0026gt; 21.6 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConductor Cross-Section (Rigid)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5...6 mm² (AWG 26...12)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConductor Cross-Section (Flexible, Input)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5...2.5 mm² (max)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e40 mm x 125 mm x 100 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e675 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eTerminal Specification \/ Function\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection for L, N, and PE (0.5 to 6 mm² rigid)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection for +24 V DC and -24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStatus Relay\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFloating contact (NO), max. 30 V DC \/ 1 A for remote diagnostics\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap vertically onto a standard TS 35 DIN rail. Ensure the internal cooling vents are positioned at the top and bottom.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain adequate clearance above and below the module to facilitate natural convection cooling and prevent thermal derating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriate wire cross-sections (up to 6 mm² for rigid conductors) and ensure screw terminals are tightened to the recommended torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the PE (Protective Earth) terminal securely to the system ground to ensure proper electromagnetic compatibility (EMC) and electrical safety.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102123811179,"sku":"PRO ECO 120W 24V 5A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469480000-41foci3xh3m.png?v=1776137074"},{"product_id":"weidmuller-1469470000-proeco-pro-eco-72w-24v-3a-switch-mode-power-supply-unit","title":"Weidmuller 1469470000 PROeco PRO ECO 72W 24V 3A Switch-Mode Power Supply Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for space-restricted control cabinets, the Weidmuller \u003cstrong\u003e1469470000\u003c\/strong\u003e (\u003cstrong\u003ePRO ECO 72W 24V 3A\u003c\/strong\u003e) provides highly efficient and reliable power conversion in a compact 34 mm housing. This industrial-grade \u003cstrong\u003eswitch-mode power supply\u003c\/strong\u003e delivers a regulated 24 V DC output with up to 87% efficiency, minimizing thermal dissipation and optimizing energy consumption. Equipped with comprehensive protection circuits, it handles wide-range AC and DC inputs, making it globally compatible with diverse automation architectures and power grids.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh efficiency rating of 87% reduces heat generation inside enclosures.\u003c\/li\u003e\n  \u003cli\u003eWide-range input capability supporting 85 to 264 V AC and 80 to 370 V DC.\u003c\/li\u003e\n  \u003cli\u003eAdjustable output voltage from 22 to 28 V DC via a front-facing potentiometer.\u003c\/li\u003e\n  \u003cli\u003eTri-color LED diagnostic indicators for real-time status monitoring (voltage, current, and faults).\u003c\/li\u003e\n  \u003cli\u003eIntegrated protection against short-circuits, overloads, and overtemperature conditions.\u003c\/li\u003e\n  \u003cli\u003eSupport for parallel connection of up to 5 units to increase capacity or build redundant systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation and control panel distribution.\u003c\/li\u003e\n  \u003cli\u003eMachine building and manufacturing process control.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility systems.\u003c\/li\u003e\n  \u003cli\u003eWind, solar, and conventional power generation control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1469470000 \/ PRO ECO 72W 24V 3A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROeco\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range (AC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85...264 V AC (derating at 100 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range (DC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80...370 V DC (derating at 120 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e47...63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.55 A @ 230 V AC \/ 1.04 A @ 110 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.22 A @ 370 V DC \/ 0.68 A @ 120 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 40 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC ± 1 %\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e22...28 V DC (adjustable via potentiometer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 A @ 55 degC \/ 2.25 A @ 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e72 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e87%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Loss (Idling \/ Nominal Load)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 W \/ 9.5 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGreen LED (Uout \u0026gt; 21.6 V DC), Yellow LED (Iout \u0026gt; 90% nominal), Red LED (overload, overtemp, short-circuit, Uout \u0026lt; 20.4 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTS 35 DIN rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC...70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC...85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePermissible Air Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5%...95% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e34 mm x 125 mm x 100 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e557 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the device vertically on a TS 35 DIN rail to ensure optimal natural convection cooling.\u003c\/li\u003e\n  \u003cli\u003eMaintain adequate clearance above and below the unit to prevent heat accumulation.\u003c\/li\u003e\n  \u003cli\u003eEnsure the protective earth (PE) terminal is securely connected to the system ground before powering the unit.\u003c\/li\u003e\n  \u003cli\u003eUse appropriately rated wire cross-sections for the screw terminals to handle nominal input and output currents.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102125023595,"sku":"PRO ECO 72W 24V 3A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469470000-4emg4pepos4.png?v=1776137073"},{"product_id":"weidmuller-1469510000-pro-eco-480w-24v-20a-pro-eco-switch-mode-power-supply-unit","title":"Weidmuller 1469510000 PRO ECO 480W 24V 20A PRO eco Switch-Mode Power Supply Unit","description":"\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEfficient power delivery in decentralized industrial automation systems is critical, and the \u003cstrong\u003eWeidmuller 1469510000\u003c\/strong\u003e switch-mode power supply unit is engineered to meet this demand. Operating within the PRO eco series, this robust power supply delivers a regulated 24 V DC output with up to 20 A of continuous current, translating to a nominal output power of 480 W. It features a wide-range AC input (85 to 264 V AC) and DC input (80 to 370 V DC) capability, making it highly adaptable to varying global grid conditions.\u003c\/p\u003e\n\n\u003cp\u003eThe compact, corrosion-resistant metal housing is optimized for space-constrained control cabinets, mounting directly onto standard TS 35 DIN rails. With an energy efficiency rating of 91%, the unit minimizes thermal dissipation, allowing reliable operation in ambient temperatures ranging from -25 degC to 70 degC. Integrated safety features include short-circuit protection, overload protection, over-temperature protection, and reverse voltage protection, ensuring maximum uptime for connected PLC, DCS, and I\/O systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-efficiency power conversion reaching up to 91% to reduce heat generation inside enclosures.\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range supporting both AC (85 to 264 V AC) and DC (80 to 370 V DC) operation.\u003c\/li\u003e\n  \u003cli\u003eAdjustable output voltage from 22 to 28 V DC via a front-facing potentiometer for precise voltage drop compensation.\u003c\/li\u003e\n  \u003cli\u003eThree-stage LED diagnostic indicator for real-time visual status monitoring of output voltage and load conditions.\u003c\/li\u003e\n  \u003cli\u003eSupport for parallel connection of up to three units to increase total output capacity or establish redundancy.\u003c\/li\u003e\n  \u003cli\u003eRobust screw connection system ensuring secure, vibration-resistant wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Weidmuller PRO eco 480W power supply is designed for deployment in demanding industrial environments, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower generation and distribution control panels.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility automation.\u003c\/li\u003e\n  \u003cli\u003eOil and gas processing plant telemetry and DCS cabinets.\u003c\/li\u003e\n  \u003cli\u003eGeneral machinery manufacturing and factory automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWeidmuller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePRO ECO 480W 24V 20A (Order No: 1469510000)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4050118275483\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85 to 264 V AC (derating at 100 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80 to 370 V DC (derating at 120 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.37 A @ 230 V AC \/ 5.2 A @ 110 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.55 A @ 370 V DC \/ 4.65 A @ 120 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC +\/- 1%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e22 to 28 V DC (adjustable via potentiometer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 A @ 55 degC, 15 A @ 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e480 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e91%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResidual Ripple \/ Breaking Spikes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 50 mVPP @ 24 V DC, IN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAC Failure Bridging Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt; 20 ms @ 230 V AC \/ \u0026gt; 20 ms @ 115 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Loss (Idling \/ Nominal Load)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 W \/ 43 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Permissible Air Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 mm x 125 mm x 120 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1557 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eStatus Indicator \/ Terminal\u003c\/th\u003e\n      \u003cth\u003eFunctional Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGreen LED\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOutput voltage is active and normal (Uoutput \u0026gt; 21.6 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eYellow LED\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHigh load warning (Ioutput \u0026gt; 90% IRated typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRed LED\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFault condition (overload, overtemperature, short-circuit, or Uoutput \u0026lt; 20.4 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew terminals for L, N, and PE connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew terminals for positive (+24 V DC) and negative (GND) connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap securely onto a standard TS 35 DIN rail. Ensure the unit is mounted vertically to facilitate natural convection cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain a minimum clearance of 50 mm above and below the unit, and 10 mm on the sides when operating under full load conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriately rated copper conductors. Ensure all screw terminals are torqued to the manufacturer's specified limits to prevent contact resistance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the protective earth (PE) terminal to the local system ground busbar prior to energizing the input power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102127645035,"sku":"PRO ECO 480W 24V 20A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469510000-g0v45txmh4l.png?v=1776137076"},{"product_id":"weidmuller-1469520000-pro-eco-960w-24v-40a-switch-mode-power-supply-unit","title":"Weidmuller 1469520000 PRO ECO 960W 24V 40A Switch-mode Power Supply Unit","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered for high-capacity DC power distribution in demanding industrial environments, the \u003cstrong\u003eWeidmuller 1469520000\u003c\/strong\u003e (Model: \u003cstrong\u003ePRO ECO 960W 24V 40A\u003c\/strong\u003e) switch-mode power supply unit delivers a regulated 24 V DC output at up to 40 A. This robust DIN-rail mountable module combines a compact form factor with 93% operational efficiency, minimizing thermal load inside control cabinets and ensuring stable power delivery to PLCs, HMIs, and field actuators.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Operational Efficiency:\u003c\/strong\u003e Achieves up to 93% efficiency, significantly reducing energy dissipation and cabinet heat buildup.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Input Range:\u003c\/strong\u003e Supports universal AC input from 85 to 264 V AC and DC input from 80 to 370 V DC for global compatibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTri-Color LED Diagnostics:\u003c\/strong\u003e Real-time status monitoring via Green (Uoutput \u0026gt; 21.6 V DC), Yellow (Ioutput \u0026gt; 90% rated), and Red (overload, short-circuit, or overtemperature) indicators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eParallel Capability:\u003c\/strong\u003e Supports direct parallel connection of up to 3 units to scale current capacity or establish redundant power architectures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Protection Suite:\u003c\/strong\u003e Integrated varistor surge protection, short-circuit protection, overload protection, and thermal shutdown.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Automation:\u003c\/strong\u003e Centralized 24 V DC power distribution for PLC racks, I\/O drops, and industrial PCs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess Control Systems:\u003c\/strong\u003e Reliable power source for transmitters, solenoid valves, and safety barriers in continuous process plants.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine Building:\u003c\/strong\u003e Heavy-duty power supply for packaging, material handling, and CNC machinery control panels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and Wastewater:\u003c\/strong\u003e Robust power infrastructure for outdoor telemetry and pump control stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eOrder Number\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eType Designation\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eGTIN \/ EAN\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eStandard Package Qty\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1469520000\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePRO ECO 960W 24V 40A\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4050118275704\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 pc(s).\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePROeco\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRated Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 V DC ± 1 % (adjustable 22 to 28 V DC via potentiometer)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eContinuous Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e40 A @ 50 degC \/ 24 A @ 70 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e960 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAC Input Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85 to 264 V AC (derating required below 100 V AC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDC Input Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e80 to 370 V DC (derating required below 120 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAC Current Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4.6 A @ 230 V AC \/ 9.9 A @ 110 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFrequency Range AC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e47 to 63 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMax. 5 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEfficiency\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e93%\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Loss (Idle \/ Nominal)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8 W (Idling) \/ 85 W (Nominal Load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnection System\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Version\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMetal, corrosion resistant\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-25 degC to 70 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e160 mm x 125 mm x 120 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3190 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eDiagnostic LED Status Mapping\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eLED Color\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eStatus \/ Threshold\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperational Meaning\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; color: green; font-weight: bold;\"\u003eGreen\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUoutput \u0026gt; 21.6 V DC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eNormal operation; output voltage within acceptable limits.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; color: #b7791f; font-weight: bold;\"\u003eYellow\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIoutput \u0026gt; 90% IRated typ.\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eHigh load warning; output current is approaching maximum capacity.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; color: red; font-weight: bold;\"\u003eRed\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUoutput \u0026lt; 20.4 V DC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eFault condition; overload, overtemperature, short-circuit, or low voltage.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The PROeco series is designed as a highly space-efficient and cost-effective alternative to Weidmuller's premium PROmax and PROtop series. When replacing older 40 A power supplies, verify the 160 mm width footprint on the TS 35 rail, as high-power units require adequate lateral spacing for heat dissipation.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  A critical consideration for the PRO ECO 960W is its thermal derating profile. While it delivers a full 40 A at ambient temperatures up to 50 degC, the output capacity derates linearly to 24 A at 70 degC. Operating the unit near its limit in unventilated enclosures will trigger the internal thermal protection, causing output cycling.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Due to the high 40 A output current, ensure that output wiring is sized appropriately (minimum 10 AWG \/ 6 mm² copper wire recommended) to prevent significant voltage drop across the run. When configuring parallel operation for up to 3 units, use a precise digital multimeter to adjust the output voltage of each unit via the front potentiometer to within ±50 mV of each other before tying the outputs together.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all AC and DC power sources before attempting installation, wiring, or maintenance. Ensure the input circuit breaker is locked out. Do not open the metal housing; high residual voltage may remain stored in internal capacitors even after power is disconnected.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eSnap the unit securely onto a standard TS 35 DIN rail. Ensure the mounting orientation is vertical, with the input terminals at the bottom and output terminals at the top to facilitate natural convection cooling.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMaintain a minimum clearance of 50 mm above and below the unit, and 20 mm of lateral clearance from adjacent active heat-producing components.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the protective earth (PE) ground terminal first. Wire the AC input (L, N) or DC input terminals using the integrated screw connections, tightening to the manufacturer-specified torque.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the 24 V DC load lines to the output terminals, ensuring correct polarity. Energize the input source and verify that the green LED illuminates.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102129054059,"sku":"PRO ECO 960W 24V 40A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469520000-hqxom15pbh5.png?v=1776137078"},{"product_id":"weidmuller-8965500000-act20-feed-in-pro-s-act20-series-power-feed-in-module","title":"Weidmuller 8965500000 ACT20-FEED-IN-PRO-S ACT20 Series Power Feed-In Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDesigned to optimize power distribution within modular DIN-rail systems, the \u003cstrong\u003eWeidmuller 8965500000 ACT20-FEED-IN-PRO-S\u003c\/strong\u003e provides a centralized feed-in point for the ACT20 series and CH20M bus system. This high-efficiency module simplifies cabinet wiring by distributing supply voltage directly to adjacent modules via the rail bus, reducing point-to-point wiring and minimizing installation time.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eHigh efficiency rating exceeding 97.9% to minimize thermal dissipation inside the enclosure.\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range of 19.2 V DC to 31.2 V DC for compatibility with standard 24 V DC industrial power supplies.\u003c\/li\u003e\n  \u003cli\u003eIntegrated screw connection technology ensuring secure, vibration-resistant field wiring.\u003c\/li\u003e\n  \u003cli\u003eSupports collective error signaling and status monitoring for enhanced system diagnostics.\u003c\/li\u003e\n  \u003cli\u003eCompact 22.5 mm width matching standard ACT20 series form factor to optimize DIN-rail space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eCentralized power distribution in industrial automation control panels.\u003c\/li\u003e\n  \u003cli\u003eSignal conditioning and isolation racks utilizing the CH20M rail bus system.\u003c\/li\u003e\n  \u003cli\u003eProcess industries requiring dense, modular DIN-rail instrument configurations.\u003c\/li\u003e\n  \u003cli\u003ePower grouping and segment isolation in complex PLC and DCS I\/O systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8965500000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eACT20-FEED-IN-PRO-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePower Feed-In Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e\u0026lt;= 2.0 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEfficiency\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e\u0026gt; 97.9%\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-20 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-20 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e119.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.140 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.20 kg (including protective packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput + \/ -\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary 24 V DC supply input connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCH20M Bus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDirect power distribution contacts to the DIN-rail bus\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStatus Relay\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCollective error message output (normally closed \/ normally open contact)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe ACT20-FEED-IN-PRO-S is fully compatible with all Weidmuller ACT20 series signal converters and isolators that utilize the CH20M DIN-rail bus. It can replace standard passive feed-in terminals when active collective error monitoring and diagnostic feedback are required for the control system.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nEnsure that the total current drawn by all modules connected to the CH20M bus does not exceed the maximum bus current rating (typically 4 A). If your module configuration exceeds this limit, you must install an additional feed-in module to segment the power distribution groups.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen wiring the collective error relay, integrate the contact into your PLC's safety loop or alarm input. This ensures that any power loss or module fault on the CH20M bus is instantly flagged in the control room, reducing troubleshooting downtime.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all primary and auxiliary power sources before mounting, removing, or wiring the module. Ensure the DIN-rail bus contacts are completely clean and properly aligned before snapping the unit onto the rail to prevent physical damage to the contact pins.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the CH20M DIN-rail bus elements onto the TS 35 DIN rail if they are not already installed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the ACT20-FEED-IN-PRO-S with the rail and snap it firmly into place, ensuring the bus connector pins seat correctly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 24 V DC input supply lines to the designated screw terminals using the correct wire gauge and torque specifications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the collective error relay output to your supervisory control system for active diagnostic monitoring.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102130594155,"sku":"8965500000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965500000-gdquort342v.png?v=1776137171"},{"product_id":"weidmuller-pro-eco-240w-24v-10a-switch-mode-power-supply","title":"Weidmüller PRO ECO 240W 24V 10A Switch-Mode Power Supply","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-886\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eWeidmüller PRO ECO 240W 24V 10A (Order No. 1469490000)\u003c\/strong\u003e\u003cspan class=\"citation-886 citation-end-886\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency, slimline switch-mode power supply designed for reliable industrial automation performance.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-885 citation-end-885\"\u003eAs part of the PRO ECO series, it balances high power density with essential functionality, making it an economical yet robust solution for machine construction and process industries.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWith a 90% efficiency rating and a compact 60mm metal housing, it is engineered to save space in the control cabinet while minimizing thermal load.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-884 citation-end-884\"\u003eIts versatile input range allows for global use, supporting both AC and DC supply voltages.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-883\"\u003eThe PRO ECO 240W features a high-grade, corrosion-resistant metal housing designed for mounting on a standard\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eTS 35 DIN rail\u003c\/strong\u003e\u003cspan class=\"citation-883 citation-end-883\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt provides a stable 24V DC output, adjustable via a front-facing potentiometer between 22V and 28V to compensate for voltage drops over long cable runs.\u003c\/p\u003e\n\u003cp\u003eOne of its standout features is the comprehensive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree-color LED diagnostic system\u003c\/strong\u003e, which provides immediate visual status of the output health, load levels, and fault conditions. The unit is built for longevity, boasting a Mean Time Between Failures (MTBF) of over 2 million hours (SN 29500 standard).\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-882 citation-end-882\"\u003eIt also supports parallel connection of up to 5 units to increase power capacity or provide redundancy in critical systems.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePRO ECO 240W 24V 10A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1469490000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Adjustable 22–28 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A @ 55 °C (Derating to 2.5 A @ 70 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85...264 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80...370 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 x 125 x 100 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit, Overload, Over-temperature, Reverse voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic LEDs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreen (OK), Yellow (\u0026gt;90% load), Red (Fault\/Overload)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,002 g (Net) \/ 2.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does the Yellow LED indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The Yellow LED is a pre-warning indicator that lights up when the output current exceeds 90% of its rated capacity (typically \u0026gt;9A). This allows maintenance teams to identify potential overloads before the system trips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I use this power supply with a DC input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the PRO ECO 240W is a wide-range input device that can operate on 80...370 V DC, making it suitable for specialized battery systems or DC bus applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is a special mounting kit required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No, the unit features an integrated snap-on foot specifically designed for standard TS 35 terminal rails.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the unit is rated for 10A at 55 °C, note that significant derating occurs at higher temperatures. If the cabinet environment reaches 70 °C, the available current drops to 2.5A. Ensure adequate spacing (approx. 50mm vertical clearance) to allow for natural convection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eParallel Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting units in parallel (max 5), ensure the output voltages are adjusted as closely as possible to the same value using the potentiometer to ensure balanced load sharing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor safety and protection of the supply line, a 10A Characteristic B or a 3-4A Characteristic C circuit breaker is recommended. The unit contains an internal fuse, but external backup fuses are required by most industrial standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBe aware of the maximum inrush current of 15A. When powering multiple units simultaneously on a single circuit, ensure the upstream breaker is sized to handle the combined peak startup current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe PRO ECO 240W is distinguished by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eActive PFC (Power Factor Correction)\u003c\/strong\u003e, which achieves a power factor of \u0026gt;0.94 at 230V AC, reducing reactive power costs and harmonic distortion.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-881\"\u003eIts\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e20ms bridging time\u003c\/strong\u003e\u003cspan class=\"citation-881 citation-end-881\"\u003e\u003cspan\u003e \u003c\/span\u003eensures that your PLC or sensitive electronics remain powered through minor mains failures or voltage dips.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFurthermore, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emetal housing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides superior electromagnetic compatibility (EMC) and mechanical durability compared to plastic-housed alternatives, making it ideal for the high-vibration and electrically noisy environments found in heavy manufacturing.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102135017835,"sku":"PRO ECO 240W 24V 10A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1469490000-fs5fbkxtsu4.png?v=1776137075"}],"url":"https:\/\/www.plcprotech.com\/bg\/collections\/weidmuller-pro-power.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}