{"product_id":"bently-nevada-3500-23e-3500-encore-transient-data-interface","title":"Bently Nevada 3500\/23E 3500 ENCORE Transient Data Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/23E Transient Data Interface (TDI)\u003c\/strong\u003e serves as the primary communications gateway between the 3500 ENCORE monitoring system and GE System 1 condition monitoring and diagnostic software. By combining the fundamental capabilities of a System Monitor with the data collection efficiency of a communication processor, the module continuously captures and transfers critical machine health data. The 3500\/23E operates in the designated System Monitor slot of a 3500 ENCORE rack alongside 3500\/42E vibration monitors, processing steady state and transient waveform data through an Ethernet link to the host system. Standard configurations include static data capture, while dynamic and transient data capture can be enabled using an optional Channel Enabling Disk.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Function Capability:\u003c\/strong\u003e Integrates full System Monitor operations with advanced data processing functions within a single slot footprint.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuous Data Logging:\u003c\/strong\u003e Enables steady state and transient data collection via high-speed Ethernet connection to host diagnostic software.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Signal Capture:\u003c\/strong\u003e Standard static data capture with upgradeable paths to dynamic and transient tracking via software licensing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Integration Protocols:\u003c\/strong\u003e Provides extensive communication mapping of rack values and machine statuses to external plant automation systems using serial RS232, RS422, or RS485 loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Security:\u003c\/strong\u003e Hardware-based configuration keylock switch restricts unauthorized remote or local modification of configuration settings when toggled to RUN mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTurbomachinery Diagnostics:\u003c\/strong\u003e Captures continuous transient waveforms during critical machinery events like startup and coastdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondition Monitoring Systems (CMS):\u003c\/strong\u003e Acts as the dedicated hardware bridge for GE System 1 asset management software integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDistributed Control System (DCS) Interfacing:\u003c\/strong\u003e Transmits critical vibration metrics and rack alarm statuses to plant control networks via Modbus RTU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRetrofit System Upgrades:\u003c\/strong\u003e Replaces legacy communication processors in 3300 rack architectures using a standardized 3500 ENCORE form factor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; color: #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px;\"\u003ePart \/ Option Number\u003c\/th\u003e\n        \u003cth style=\"padding: 10px;\"\u003eDescription\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e3500\/23E-AXX-BXX\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTransient Data Interface Main Assembly (A: I\/O Module Type, B: Agency Approval Option)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e3500\/23E-A00-B00\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTDI Module with no new I\/O module (uses existing 3300 PIM), no agency approvals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e3500\/23E-A00-B01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTDI Module for 3300 PIM retrofit, including North American Hazardous Area Approvals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e285690-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSpare Parts: Replacement 3500\/23E TDI Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e287545-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSpare Parts: 3500\/23E Monitor User Manual\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; color: #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; width: 30%;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; width: 70%;\"\u003eSpecification Details\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (General Electric \/ Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRack Slot Requirement\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 full-height front slot (Must always occupy Slot 1, adjacent to power supplies)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFront Panel Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4 Buffered Transducer Outputs (BNC connections)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEthernet Communications\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 Ports, 10Base-T or 100Base-TX Ethernet, autosensing, RJ-45 connectors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSerial Communications\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRS232, RS422, or RS485; Baud rates from 1200 baud minimum up to 115.2 kbaud maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSupported Protocols\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBN Host Protocol, BN TDI Protocol (TCP\/IP), Modbus RTU (transmission mode)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eKeyphasor Support\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUp to 4 system Keyphasor signals; supports events per revolution up to 20 kHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 degC to plus 65 degC (minus 22 Fahrenheit to plus 149 Fahrenheit). Requires minimum 300 ft\/min air flow above plus 55 degC.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e95 percent, non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHazardous Area Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eClass 1, Div 2, Groups A, B, C, D (T4A at Ta = minus 20 degC to plus 60 degC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModule Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e228 mm x 50 mm x 289 mm (8.97 in x 1.98 in x 11.39 in)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Module Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.45 kg (3.2 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.10 kg (4.6 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #2b6cb0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e350 mm x 120 mm x 330 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Isolate all hazardous field power sources and completely de-energize the host machinery rack before inserting or removing the interface module. Failure to properly discharge field electronics or working on live equipment in active zones can trigger unexpected machine trips, compromise system validation, or invalidate safety certifications within hazardous locations.\n\u003c\/div\u003e\n\n\u003col style=\"padding-left: 0; list-style: none;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #1a365d; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eLocate the primary System Monitor slot inside the 3500 ENCORE chassis. This unit must always be inserted into \u003cstrong\u003eSlot 1\u003c\/strong\u003e, directly positioned next to the rack power supply assemblies.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #1a365d; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eAlign the physical card along the top and bottom guide rails of Slot 1. Push the module firmly straight back into the slot until the rear connectors mate securely with the chassis backplane. Tighten the panel retaining screws to secure the faceplate.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #1a365d; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eConnect your dedicated communication infrastructure. Terminate Ethernet networks into the standard RJ-45 ports or tie serial logic lines into the 9-pin D-Sub interface based on Modbus or BN Host protocol deployment parameters.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #1a365d; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eInsert the physical system configuration key into the faceplate switch. Turn the mechanism to \u003cstrong\u003ePROGRAM mode\u003c\/strong\u003e to push parameter profiles through the 3500 Configuration Software, then lock the hardware back into \u003cstrong\u003eRUN mode\u003c\/strong\u003e to enforce configuration writes lockout and protect against unauthorized tampering.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666856898923,"sku":"3500\/23E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-23e-transient-data-interface-3qwqghtqmpn_81d42058-86f9-4ff2-aa77-82548ef40e87.jpg?v=1765449201","url":"https:\/\/www.plcprotech.com\/bg\/products\/bently-nevada-3500-23e-3500-encore-transient-data-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}