{"product_id":"omron-e5cc-rx2adm-800-e5cc-series-digital-temperature-controller","title":"Omron E5CC-RX2ADM-800 E5CC Series Digital Temperature Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for highly precise thermal process regulation, the \u003cstrong\u003eOmron E5CC-RX2ADM-800\u003c\/strong\u003e digital temperature controller delivers advanced PID control within a compact 48x48 mm (1\/16 DIN) form factor. This instrument features a high-contrast white LCD display with 15.2 mm character heights, ensuring maximum legibility in high-density control panels. Operating on a \u003cstrong\u003e24 VAC\/VDC\u003c\/strong\u003e auxiliary power supply, the unit integrates 2-PID control logic with automatic tuning to minimize overshoot and stabilize temperature fluctuations in demanding thermal systems. Built with a \u003cstrong\u003erelay control output\u003c\/strong\u003e and dual auxiliary outputs, this hardware is engineered for direct integration into industrial machines, packaging lines, and environmental chambers.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Sensor Input:\u003c\/strong\u003e Direct support for multi-range thermocouples, platinum resistance thermometers (RTDs), and analog current\/voltage inputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Auxiliary Relays:\u003c\/strong\u003e Two independent auxiliary relay outputs for alarms, limit controls, or system interlocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Control Algorithms:\u003c\/strong\u003e High-speed sampling loop of 50 ms combined with 2-PID control and auto-tuning (AT) capabilities.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Visibility:\u003c\/strong\u003e Large, easy-to-read white PV display segment contrasted against a dark background.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Depth:\u003c\/strong\u003e Only 60 mm depth behind the panel, minimizing enclosure footprint and maximizing wiring space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlastic Extrusion \u0026amp; Molding:\u003c\/strong\u003e Accurate barrel zone heating control and die temperature stabilization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e Precise sealing bar temperature management to ensure consistent package integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Ovens \u0026amp; Furnaces:\u003c\/strong\u003e High-reliability thermal profiling and multi-stage heating curve regulation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFood \u0026amp; Beverage Processing:\u003c\/strong\u003e Sanitation-compliant temperature monitoring and pasteurization loop control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eE5CC-RX2ADM-800\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 VAC (50\/60 Hz) \/ 24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85% to 110% of rated supply voltage\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMax 4.1 VA (24 VAC) \/ Max 2.3 W (24 VDC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eControl Output 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRelay output (SPST-NO, 250 VAC, 3 A resistive load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAuxiliary Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 Relay outputs (SPST-NO, 250 VAC, 3 A resistive load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eControl Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eON\/OFF control or 2-PID control (with auto-tuning)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSampling Period\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e50 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTerminal Connection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eScrew terminal block (M3)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFront Panel Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 48 mm x 48 mm (1\/16 DIN);\"\u003e48 x 48 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Ambient Temp\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-10 to 55 degC (with no condensation or icing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.35 kg;\"\u003e0.35 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e110 mm x 65 mm x 65 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E5CC-RX2ADM-800 serves as a direct functional replacement for legacy models such as the E5CN-R2MD-500 series. However, when migrating to the E5CC platform, verify the wiring terminations: the E5CC uses a different physical pin layout relative to older generations. If your application relies on voltage pulse output for solid-state relays (SSRs), do not use the RX model; select the E5CC-QX2ADM-800 instead to prevent damage to the relay mechanism caused by high-frequency switching.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this model is rated for 24 VAC\/VDC power, it is highly sensitive to voltage drops along long DC distribution lines in control panels. Ensure that the power supply is situated close to the instrument and is isolated from heavy inductive switching devices. Running auxiliary outputs with high-current AC loads near their 3 A limit without RC snubbers will significantly shorten the electrical lifespan of the internal output relays due to contact arcing.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo configure parameters prior to cabinet powering, use the Omron CX-Thermo software paired with the front-panel setup port interface. This approach allows parameter configuration over a USB bus power connection, completely eliminating the need to connect 24V field power during the engineering phase. Ensure that you ground the analog shield wire of the sensor close to the panel entry point rather than routing it alongside high-voltage AC cables.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to attempting physical installation, mounting, or terminal wiring, ensure that the primary electrical power source to the control cabinet is completely de-energized. Confirm the absence of residual AC\/DC voltages using a calibrated digital multimeter. Failure to isolate power may cause electrical shock, physical hazard, or permanent failure of the internal logic circuits.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInsert the controller housing through the prepared 45x45 mm panel cutout from the front, ensuring the protective rubber gasket is correctly seated to maintain the IP66 water-resistant seal.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSlide the plastic mounting adapter from the rear of the panel along the controller body until the adapter clicks firmly against the panel backplate. Tighten the securing screws evenly to prevent frame distortion.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eTerminate the universal input lines (thermocouple or RTD) using high-quality insulated crimp lugs to avoid signal noise. Route power and control output wires along dedicated low-voltage wireways separated from motor drive leads.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077930574187,"sku":"E5CC-RX2ADM-800","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e5cc-rx2adm-800-h3oq5agjyra.png?v=1775733752","url":"https:\/\/www.plcprotech.com\/bg\/products\/omron-e5cc-rx2adm-800-e5cc-series-digital-temperature-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}