{"product_id":"omron-v680-hs52-w-v680-series-cylindrical-antenna","title":"Omron V680-HS52-W V680 Series Cylindrical Antenna","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for robust industrial RFID deployment, the \u003cstrong\u003eOmron V680-HS52-W\u003c\/strong\u003e is a cylindrical read\/write RFID antenna engineered to operate within the established Omron V680 series system architecture. This \u003cstrong\u003ecylindrical antenna\u003c\/strong\u003e features an M22 threaded body design that facilitates straightforward mechanical mounting and integration into automated machinery. Built to endure challenging operational environments, the unit is fitted with a standard cable terminated by a waterproof connector, safeguarding high-frequency signal transmissions against moisture and particulate ingress.\u003c\/p\u003e\n\n\u003cp\u003eThe module achieves reliable data communication with compatible RFID tags, providing steady performance in assembly line automation, inventory tracking, and materials handling. Its heavy-duty construction provides high insulation resistance alongside superior mechanical resistance to vibration and physical shock, ensuring continuous operation on the factory floor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eStandardized cylindrical M22 threaded profile for easy mounting and positioning.\u003c\/li\u003e\n  \u003cli\u003eEquipped with a standard cable and integrated waterproof connector to maintain IP-rated sealing.\u003c\/li\u003e\n  \u003cli\u003eHigh shock resistance rating of 500 m\/s2 across three orthogonal axes.\u003c\/li\u003e\n  \u003cli\u003eRobust vibration tolerance designed to withstand variable industrial frequencies up to 500 Hz.\u003c\/li\u003e\n  \u003cli\u003eExcellent electrical isolation with a minimum insulation resistance of 20 MOhm at 500 VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive assembly line tracking and component verification.\u003c\/li\u003e\n  \u003cli\u003eAutomated conveyor systems and sorting facilities.\u003c\/li\u003e\n  \u003cli\u003eIntralogistics and industrial warehouse tracking.\u003c\/li\u003e\n  \u003cli\u003eMachine tool identification and automated tool changers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eV680-HS52-W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eV680 Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCylindrical RFID Antenna\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size \/ Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM22 x 65 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with waterproof connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 MOhm minimum (at 500 VDC) between the cable terminals and the case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-10 degC to 60 degC (with no icing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 m\/s2 in X, Y, and Z directions 3 times each (18 times total)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 to 500 Hz variable vibration, 1.5-mm double amplitude at 100 m\/s2 acceleration, 10 sweeps in X, Y, and Z directions for 8 minutes each\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.85 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal RF performance and mechanical longevity, adhere to the following installation parameters:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDo not exceed the specified tightening torque when mounting the M22 threaded body into metallic or non-metallic brackets.\u003c\/li\u003e\n  \u003cli\u003eProvide sufficient bend radius for the standard antenna cable to prevent long-term stress fatigue at the entry point of the housing.\u003c\/li\u003e\n  \u003cli\u003eRoute the communication and RF cable away from high-voltage power lines and variable frequency drives (VFD) to minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eEnsure the waterproof connector is fully engaged and locked to prevent fluid entry into the contact pins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077928739179,"sku":"V680-HS52-W","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/v680-hs52-w-u5214zkteae.png?v=1775734096","url":"https:\/\/www.plcprotech.com\/bg\/products\/omron-v680-hs52-w-v680-series-cylindrical-antenna","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}