{"title":"Bently Nevada 3300 System Monitoring","description":"\u003cp\u003eThe Bently Nevada 3300 System Monitoring platform is a legacy machinery protection solution widely recognized for its reliability in industrial environments. Its architecture features a rack-based design housing individual monitors for vibration, temperature, and thrust, supported by common power supplies and communication modules. Technical characteristics include analog meter displays or digital readouts, with robust relay logic for machine protection. Functionally, the 3300 system interfaces with \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-7200-3300-interconnect-cables\"\u003e7200 \u0026amp; 3300 interconnect cables\u003c\/a\u003e and sensors to provide real-time status of rotating machinery. While succeeded by the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3500-system-machinery-protection\"\u003e3500 System\u003c\/a\u003e, the 3300 series remains a critical component in many plants, requiring high-quality spare parts to ensure continued operation and protection of essential turbines, pumps, and industrial motors.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-3300-30-six-channel-temperature-tc-input-monitor","title":"Bently Nevada 3300\/30 Six-Channel Temperature TC Input Monitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/30 Six-Channel Temperature Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a six-channel temperature monitoring module designed for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e.\u003cbr\u003eThis version is specifically configured to accept\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThermocouple (TC) inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erather than RTD sensors.\u003c\/p\u003e\n\u003cp\u003eIt is commonly used to monitor critical temperature points in industrial machinery, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBearing metal temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExhaust gas temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStator winding temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLube oil system temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe monitor provides continuous protection through configurable alarm relays and standard recorder outputs, ensuring reliable thermal supervision in turbine, compressor, and generator applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003e1. Inputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esix (6) independent thermocouple inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEach channel operates independently\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Thermocouple Types\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Iron \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Alumel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Copper \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInternal compensation provided at the terminal block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatically corrects measurement drift caused by ambient temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures stable temperature accuracy across operating environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWithin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±2.2% of signal\u003c\/strong\u003e, plus thermocouple tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReference temperature:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOpen Thermocouple Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor includes automatic fault detection when a thermocouple circuit opens.\u003c\/p\u003e\n\u003cp\u003eSelectable response modes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to high value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDownscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to low value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis feature prevents machinery from operating without temperature protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAll six channels scanned approximately:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.5 seconds per cycle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis scan speed is typical for machinery protection systems where temperature changes occur gradually compared to vibration signals.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Outputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUser-programmable analog outputs:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 to +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to -10 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 to +5 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvailable for diagnostic and monitoring purposes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel coaxial connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRear terminal block connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne buffered output per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese outputs are typically connected to:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDCS systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData recorders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. Alarms \u0026amp; Display\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e7-segment LCD temperature display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShows real-time temperature value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChannel selection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebutton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCycles through Channel 1 to Channel 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach channel supports independent alarm configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlert alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDanger alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth thresholds are fully adjustable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOK Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinuously monitors system health, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/30-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003chr\u003e\n\u003ch3\u003eA — Full-Scale Range Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eTemperature Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0 to 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0 to 500°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0 to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e32 to 212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e32 to 392°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e32 to 932°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003e32 to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — Thermocouple Input Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eThermocouple Type\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — Alarm Relay Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — Agency Approval Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCertification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX self-certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — Safety Barrier Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eExternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eInternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eSpace Requirement\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/30 temperature monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDouble-width module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation requirement:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOccupies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo (2) slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the 3300 rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is important when planning rack capacity in retrofit or expansion projects.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThermocouple Lead Wire Requirement\u003c\/h3\u003e\n\u003cp\u003eAlways use the correct\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouple extension wire\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat matches the thermocouple type.\u003c\/p\u003e\n\u003cp\u003eExamples:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType K → Type K extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType J → Type J extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing standard copper wire will introduce:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eJunction voltage errors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement drift\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration inaccuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is one of the most common field installation mistakes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGrounding Practice\u003c\/h3\u003e\n\u003cp\u003eRecommended grounding method:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround the thermocouple shield at the monitor rack only\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvoid grounding at multiple points.\u003c\/p\u003e\n\u003cp\u003eImproper grounding can cause:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGround loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnstable temperature readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpecial attention is required when using:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounded-tip thermocouples\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese sensors are more sensitive to grounding configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCold Junction Environment Control\u003c\/h3\u003e\n\u003cp\u003eDo not install the monitor rack in locations with:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRapid temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong airflow across terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh thermal gradients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese conditions can affect the accuracy of the internal cold junction compensation.\u003c\/p\u003e\n\u003cp\u003eTypical problematic locations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNear ventilation ducts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClose to turbine exhaust paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutdoor panels without thermal shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850935147,"sku":"3300\/30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-30-position-monitor-module-aahygilvquw_7ed0cd2c-10d0-4b8c-b33c-9c8d65d61045.jpg?v=1765449041"},{"product_id":"bently-nevada-3300-45-dual-differential-expansion-monitor","title":"Bently Nevada 3300\/45 Dual Differential Expansion Monitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/45 Dual-Channel Differential Expansion Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel monitor designed for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e.\u003cbr\u003eIt is specifically engineered to measure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDifferential Expansion\u003c\/strong\u003e, defined as the relative axial movement between the turbine shaft and the casing.\u003c\/p\u003e\n\u003cp\u003eThis parameter is critical for large steam turbines during startup and shutdown, where thermal expansion rates differ between rotating and stationary components. Accurate monitoring helps prevent rotor-to-casing contact, mechanical stress, and potential turbine damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003e1. Input \u0026amp; Signal Processing\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Input\u003c\/strong\u003e\u003cbr\u003eAccepts signals from non-contacting proximity probes, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e11 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e25 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor supports multiple configuration methods depending on the mechanical design:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Single Composite\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUses one probe to measure a tapered collar or ramp surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommon in compact turbine designs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDual Complementary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUses two probes to increase measurement linearity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides redundancy for critical protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e±0.33% of full-scale (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReference temperature:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Outputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUser-programmable signal formats:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 to +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to -10 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 to +5 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel: Coaxial connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRear panel: Terminal block connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne output per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e100 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Alarms \u0026amp; Display\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual vertical bargraph LCD indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time differential expansion visualization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBi-directional alarm configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlert Alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDanger Alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigitally adjustable thresholds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOK Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OK LED monitors the health status of:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnected transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/45-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003ch3\u003eA — Full-Scale Range Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eMeasurement Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0.1-0-0.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0.2-0-0.2 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0.3-0-0.3 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0.4-0-0-0.4 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e2.0-0-2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e4.0-0-4.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e8.0-0-8.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e10-0-10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — Transducer Input Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCompatible Proximitor System\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e8 mm or 11 mm (200 or 100 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e25 mm (50 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e50 mm (25 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e7200 14 mm (100 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — Alarm Relay Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eQuad relay (Epoxy-sealed only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — Agency Approval Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCertification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX self-certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — Safety Barrier Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eExternal barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eInternal barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eTapered Collar Configuration\u003c\/h3\u003e\n\u003cp\u003eWhen a single probe is installed on a tapered collar:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe collar angle must be accurately configured in the monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThis ensures correct linear conversion from displacement to expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIncorrect angle configuration will directly affect measurement accuracy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCold vs. Hot Zero Reference\u003c\/h3\u003e\n\u003cp\u003eDifferential expansion monitoring follows a standard baseline method:\u003c\/p\u003e\n\u003cp\u003eCold condition:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe system is zeroed during machine startup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft and casing temperatures are stable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHot condition:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe monitor tracks expansion as thermal growth occurs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time displacement is calculated relative to the cold reference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis method is standard practice for steam turbine protection systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eRelay Voting Strategy (Recommended for Critical Turbines)\u003c\/h3\u003e\n\u003cp\u003eFor high-integrity protection systems:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAND voting logic (2-out-of-2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis recommended.\u003c\/p\u003e\n\u003cp\u003eThis configuration ensures:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA single probe failure will not trigger a false trip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoth channels must confirm an alarm condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis approach is widely used in turbine protection architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProbe Linearity Considerations\u003c\/h3\u003e\n\u003cp\u003eLarge-range proximity probes require precise mechanical setup.\u003c\/p\u003e\n\u003cp\u003eImportant differences:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e25 mm and 50 mm probes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHave a wider measurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRequire specific initial gap settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExhibit different linear regions compared to standard 8 mm probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImproper probe gapping may result in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReduced measurement accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-linear output response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFalse alarm conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852999531,"sku":"3300\/45","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-45-dual-differential-expansion-monitor-qopi2y5bigd_db33166e-83e4-4748-8b37-e0fd75bd5170.jpg?v=1765449102"},{"product_id":"bently-nevada-3300-12-power-supply-module","title":"Bently Nevada 3300\/12 AC Power Supply","description":"\u003cp\u003e\u003cspan class=\"citation-896\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-896\"\u003eBently Nevada 3300\/12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-896\"\u003e\u003cspan\u003e \u003c\/span\u003eis an AC power supply that provides reliable, regulated power for up to 12 monitors and their associated transducers within a 3300 rack\u003c\/span\u003e\u003cspan class=\"citation-896 citation-end-896\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-895\"\u003e\u003c\/span\u003eIt is installed in the left-most position (Position 1) of the rack\u003cspan class=\"citation-895 citation-end-895\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan class=\"citation-894\"\u003e\u003c\/span\u003eTechnical Specifications\u003cspan class=\"citation-894 citation-end-894\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ch4\u003e1. Input Power\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003eVoltage Options\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e: User-selectable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003e95 to 125 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e\u003cspan\u003e \u003c\/span\u003e(1.0 A max) or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003e190 to 250 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e\u003cspan\u003e \u003c\/span\u003e(0.5 A max), single phase, 50 to 60 Hz\u003c\/span\u003e\u003cspan class=\"citation-893 citation-end-893\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-892\"\u003eField Changeable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-892\"\u003e: The input voltage can be changed in the field via a soldered jumper and by replacing the external fuse\u003c\/span\u003e\u003cspan class=\"citation-892 citation-end-892\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-891\"\u003ePower-up Surge\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-891\"\u003e: 26 A peak or 12 A rms for one cycle\u003c\/span\u003e\u003cspan class=\"citation-891 citation-end-891\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Outputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-890\"\u003eTransducer Power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-890\"\u003e: Delivers regulated DC voltage internal to the rack\u003c\/span\u003e\u003cspan class=\"citation-890 citation-end-890\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003eProgrammable Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e: Field-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003e-24 Vdc\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e\u003cspan\u003e \u003c\/span\u003e(+0%, -2.5%) or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003e-18 Vdc\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e\u003cspan\u003e \u003c\/span\u003e(+1%, -2%)\u003c\/span\u003e\u003cspan class=\"citation-889 citation-end-889\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-888\"\u003eProtection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-888\"\u003e: Transducer voltages are overload protected on individual monitor circuit boards\u003c\/span\u003e\u003cspan class=\"citation-888 citation-end-888\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"citation-887\"\u003e\u003c\/span\u003e\u003cstrong\u003e3. OK Relay\u003c\/strong\u003e\u003cspan class=\"citation-887 citation-end-887\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e: Provides a system-level status indication.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-886\"\u003e\u003c\/span\u003eLoss of primary power, monitor failure, or transducer wiring failure will cause the relay to change state\u003cspan class=\"citation-886 citation-end-886\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-885\"\u003eType\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-885\"\u003e: Single-pole, double-throw (SPDT)\u003c\/span\u003e\u003cspan class=\"citation-885 citation-end-885\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-884\"\u003eSealing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-884\"\u003e: Hermetically-sealed\u003c\/span\u003e\u003cspan class=\"citation-884 citation-end-884\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Ratings\u003c\/strong\u003e: 5 A at 28 Vdc or 120 Vac;\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-883\"\u003e\u003c\/span\u003e3 A at 220 Vac (resistive load)\u003cspan class=\"citation-883 citation-end-883\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-882\"\u003eOperation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-882\"\u003e: Normally energized\u003c\/span\u003e\u003cspan class=\"citation-882 citation-end-882\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-881\"\u003e\u003c\/span\u003e4. Physical \u0026amp; Environmental\u003cspan class=\"citation-881 citation-end-881\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-880\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-880\"\u003e: 0°C to +65°C (+32°F to +150°F)\u003c\/span\u003e\u003cspan class=\"citation-880 citation-end-880\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-879\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-879\"\u003e: -40°C to +85°C (-40°F to +185°F)\u003c\/span\u003e\u003cspan class=\"citation-879 citation-end-879\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-878\"\u003eHumidity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-878\"\u003e: Up to 95% non-condensing\u003c\/span\u003e\u003cspan class=\"citation-878 citation-end-878\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-877\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-877\"\u003e: 1 kg (2.2 lbs.)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-876\"\u003e\u003c\/span\u003eOrdering Information (Suffix Codes)\u003cspan class=\"citation-876 citation-end-876\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOrder Format: 3300\/12-AXX-BXX-CXX\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-875\"\u003eA: Input Voltage Option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-875\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-875 citation-end-875\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 95-125 Vac, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 190-250 Vac, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-874\"\u003eB: Power Input Module (PIM) Option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-874\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-874 citation-end-874\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20\u003c\/strong\u003e: Standard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e22\u003c\/strong\u003e: Internal Safety Barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e23\u003c\/strong\u003e: Spare supply only (No PIM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-873\"\u003eC: Agency Approval Option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-873\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-873 citation-end-873\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Not Required\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-872\"\u003e01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-872\"\u003e: CSA\/NRTL\/C (Class I, Div 2)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-872 citation-end-872\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-871\"\u003e02\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-871\"\u003e: ATEX self-certification\u003c\/span\u003e\u003cspan class=\"citation-871 citation-end-871\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eImportant Notes for Installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-870\"\u003eRedundancy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-870\"\u003e: A second power supply is\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-870\"\u003enever required\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-870\"\u003e\u003cspan\u003e \u003c\/span\u003ein the same 3300 rack\u003c\/span\u003e\u003cspan class=\"citation-870 citation-end-870\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-869\"\u003eNoise Filtering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-869\"\u003e: The 3300\/12 comes equipped with a line noise filter as standard\u003c\/span\u003e\u003cspan class=\"citation-869 citation-end-869\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-868\"\u003eSafety\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-868\"\u003e: It is strongly recommended to connect an external annunciator to the OK relay terminals to ensure operators are alerted to a loss of machinery protection\u003c\/span\u003e\u003cspan class=\"citation-868 citation-end-868\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666855850347,"sku":"3300\/12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-12-power-supply-module-rdqathnprlx_e7da0184-0869-4ca4-9c0f-d1e92e31bca5.jpg?v=1765449181"},{"product_id":"bently-nevada-3300-16-dual-xy-rv-vibration-monitor","title":"Bently Nevada 3300\/16 Dual XY\/RV Vibration Monitor","description":"\u003cp\u003e\u003cspan class=\"citation-826\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/16\u003c\/strong\u003e\u003cspan class=\"citation-826\"\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel vibration monitor from the legacy\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e3300 Monitoring System\u003c\/strong\u003e\u003cspan class=\"citation-826 citation-end-826\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed to provide continuous, online protection for rotating machinery by measuring radial vibration (RV) or XY shaft orbit. This module is essential for monitoring the mechanical health of centrifugal compressors, pumps, and motors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003e1. Input\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-825\"\u003e\u003c\/span\u003e\u003cstrong\u003eTransducer Type:\u003c\/strong\u003e\u003cspan class=\"citation-825\"\u003e\u003cspan\u003e \u003c\/span\u003eAccepts signals from Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eProximitor\u003c\/strong\u003e\u003cspan class=\"citation-825 citation-end-825\"\u003e\u003cspan\u003e \u003c\/span\u003eTransducer systems (non-contacting proximity probes).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensitivity:\u003c\/strong\u003e\u003cspan class=\"citation-824\"\u003e\u003cspan\u003e \u003c\/span\u003eUser-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e200 mV\/mil\u003c\/strong\u003e\u003cspan class=\"citation-824\"\u003e\u003cspan\u003e \u003c\/span\u003e(8 V\/mm) or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e100 mV\/mil\u003c\/strong\u003e\u003cspan class=\"citation-824 citation-end-824\"\u003e\u003cspan\u003e \u003c\/span\u003e(4 V\/mm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-823\"\u003e\u003c\/span\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cspan class=\"citation-823 citation-end-823\"\u003e\u003cspan\u003e \u003c\/span\u003e10 kOhm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Signal Conditioning\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Hz to 4.2 kHz (240 cpm to 252,000 cpm) for standard applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWithin ±0.33% of full-scale at room temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-822\"\u003e\u003c\/span\u003e\u003cstrong\u003ePeak-to-Peak Measurement:\u003c\/strong\u003e\u003cspan class=\"citation-822 citation-end-822\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitors the overall vibration displacement in mils or micrometers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e3. Outputs\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs:\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e\u003cspan\u003e \u003c\/span\u003eUser-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e+4 to +20 mA\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e0 to -10 Vdc\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e+1 to +5 Vdc\u003c\/strong\u003e\u003cspan class=\"citation-821 citation-end-821\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOutputs are proportional to the full-scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-820\"\u003e\u003c\/span\u003e\u003cstrong\u003eBuffered Transducer Outputs:\u003c\/strong\u003e\u003cspan class=\"citation-820 citation-end-820\"\u003e\u003cspan\u003e \u003c\/span\u003eAvailable via front panel coaxial connectors and rear terminal blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 Ohm (for voltage outputs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e4. Alarms \u0026amp; Displays\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisplays:\u003c\/strong\u003e\u003cspan class=\"citation-819 citation-end-819\"\u003e\u003cspan\u003e \u003c\/span\u003eDual vertical LCD bargraphs (one per channel).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlert and Danger levels are digitally adjustable from 0 to 100% of full-scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOK LED:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors the integrity of the probe, cable, and internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information (Suffix Codes)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format: 3300\/16-AXX-BXX-CXX-DXX-EXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eA: Full-scale Range Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 0-3 mils (peak-to-peak)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 0-5 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 0-10 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 0-15 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 0-100 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e07\u003c\/strong\u003e: 0-150 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e08\u003c\/strong\u003e: 0-200 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e09\u003c\/strong\u003e: 0-250 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eB: Transducer Input Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 3300 or 7200 Proximitor system (200 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 7200 11 mm Proximitor system (100 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 7200 14 mm Proximitor system (100 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 3300XL NSv and 3300 RAM (200 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eC: Alarm Relay Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-818\"\u003e\u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan class=\"citation-818 citation-end-818\"\u003e: Epoxy-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-817\"\u003e\u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan class=\"citation-817 citation-end-817\"\u003e: Hermetically-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Quad Relay (Epoxy-sealed only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: Spare Monitor - No SIM\/SIRM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eD: Agency Approval Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: CSA\/NRTL\/C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-816\"\u003e\u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan class=\"citation-816 citation-end-816\"\u003e: ATEX self-certification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eE: Safety Barrier Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: None\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: External\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Internal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eXY Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn XY monitoring, two probes are mounted 90 degrees apart on the same bearing.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-815 citation-end-815\"\u003eThe 3300\/16 processes these inputs to provide a comprehensive view of the shaft's radial movement (orbit).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Voting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe monitor is typically configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOR voting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Danger relay actuates if either channel reaches the setpoint) for radial vibration, unlike thrust monitors which often use AND voting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent interference, ensure the shield of the extension cable is grounded at the monitor end only. Never ground the shield at the Proximitor housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen replacing a module, the \"Bypass\" switch must be used to inhibit the relays and prevent a false machine trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860765547,"sku":"3300\/16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-16-dual-vibration-monitor-5zzrar1f3x1_a92c3e62-5038-4339-887c-ef3cde16ad1f.jpg?v=1765449289"},{"product_id":"bently-nevada-3300-35-six-channel-temperature-monitor","title":"Bently Nevada 3300\/35 Six-Channel Temperature Monitor","description":"\u003cp\u003e\u003cspan class=\"citation-786\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/35\u003c\/strong\u003e\u003cspan class=\"citation-786\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized temperature monitoring module within the legacy\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e3300 Monitoring System\u003c\/strong\u003e\u003cspan class=\"citation-786 citation-end-786\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-785 citation-end-785\"\u003eIt is designed to provide six independent channels of continuous, online temperature monitoring for critical machinery.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis module is specifically used with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eResistance Temperature Detectors (RTDs)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto monitor bearing temperatures, stator windings, and other vital thermal points in turbines, compressors, and pumps.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300\/35\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResistance Temperature Detectors (RTD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2.2% of signal (at +25°C \/ +77°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+4 to +20 mA, 0 to -10 Vdc, or +1 to +5 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +65°C (+32°F to +150°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo rack positions (Occupies 2 slots in 3300 Rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.8 kg to 2.8 kg (depending on configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-784\"\u003e\u003c\/span\u003e\u003cstrong\u003eSix Independent Channels\u003c\/strong\u003e\u003cspan class=\"citation-784 citation-end-784\"\u003e: Monitors six separate points simultaneously, allowing for comprehensive thermal protection in a compact footprint.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-783\"\u003e\u003c\/span\u003e\u003cstrong\u003eRTD Support\u003c\/strong\u003e\u003cspan class=\"citation-783 citation-end-783\"\u003e: Optimized for standard RTD types, most commonly 100\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003cspan class=\"citation-782 citation-end-782\"\u003e\u003cspan\u003e \u003c\/span\u003ePlatinum (0.00385 coefficient).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-781\"\u003e\u003c\/span\u003e\u003cstrong\u003eAlarms\u003c\/strong\u003e\u003cspan class=\"citation-781\"\u003e: Provides configurable\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eAlert\u003c\/strong\u003e\u003cspan class=\"citation-781\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eDanger\u003c\/strong\u003e\u003cspan class=\"citation-781 citation-end-781\"\u003e\u003cspan\u003e \u003c\/span\u003esetpoints for each channel to trigger early warnings or automatic machine trips.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFront Panel Interface\u003c\/strong\u003e: Features a 7-segment LCD display (instead of the bargraphs used on vibration modules) to show actual temperature values per channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information (Suffix Codes)\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/35 is configured using the following suffix code format:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/35-AXX-BXX-CXX-DXX-EXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eA: Full-scale Range Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 0 to 100°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 0 to 200°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 0 to 150°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 0 to 250°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 32 to 212°F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-780\"\u003e\u003c\/span\u003e\u003cstrong\u003e06\u003c\/strong\u003e\u003cspan class=\"citation-780 citation-end-780\"\u003e: 32 to 392°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cem\u003e(Other regional and custom ranges available)\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eB: Transducer Input Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 100 Ohm Platinum (0.00385) - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 100 Ohm Platinum (0.00392) - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 10 Ohm Copper - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 120 Ohm Nickel - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 100 Ohm Platinum (0.00385) - 4-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eC: Alarm Relay Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-773\"\u003e\u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan class=\"citation-773 citation-end-773\"\u003e: Epoxy-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Hermetically-sealed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eD: Agency Approval Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-772\"\u003e\u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan class=\"citation-772 citation-end-772\"\u003e: Not required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: CSA\/NRTL\/C (Class 1, Div 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: ATEX self-certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eE: Safety Barrier Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: None\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: External Barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Internal Barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-771\"\u003e\u003c\/span\u003e\u003cstrong\u003eSpace Requirements\u003c\/strong\u003e\u003cspan class=\"citation-771\"\u003e: Unlike standard vibration monitors that occupy one slot, the 3300\/35 is a \"Double-Wide\" module and\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eoccupies two rack positions\u003c\/strong\u003e\u003cspan class=\"citation-771 citation-end-771\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e: For 3-wire RTDs, lead wire resistance compensation is critical for accuracy. Use high-quality shielded triad cable for all field connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLCD Display\u003c\/strong\u003e: The front panel \"Display\" button allows the user to cycle through the six channels to view current values, Peak Hold values, and Alarm Setpoints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863747435,"sku":"3300\/35","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-35-temperature-monitor-f4b5b4r5dcr_0c3a1823-f486-49d2-a5b3-91e8d2609dfd.jpg?v=1765449384"},{"product_id":"bently-nevada-3300-20-dual-thrust-position-monitor","title":"Bently Nevada 3300\/20 Dual Thrust Position Monitor","description":"\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-730\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-730\"\u003eBently Nevada 3300\/20\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-730\"\u003e is designed to provide early warning of thrust bearing failure by continuously monitoring two independent channels of shaft axial position\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-730 citation-end-730\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-729\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-729\"\u003eIt is highly recommended to use a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-729\"\u003e2-out-of-2 (AND voting)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-729\"\u003e configuration to prevent false trips caused by transducer failure\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-729 citation-end-729\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003e1. Input \u0026amp; Signal Processing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-728\"\u003eSignal Input:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-728\"\u003e Accepts one or two proximity probe signal inputs\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-728 citation-end-728\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-727\"\u003eInput Impedance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-727\"\u003e 10 kΩ\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-727 citation-end-727\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-726\"\u003eSensitivity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-726\"\u003e User-programmable for 200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-726 citation-end-726\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-725\"\u003eAccuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-725\"\u003e Within ±0.33% of full-scale typical, ±1% maximum at +25°C (+77°F)\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-725 citation-end-725\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-724\"\u003eNominal Consumption:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-724\"\u003e 1.5 watts\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-724 citation-end-724\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Outputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-723\"\u003eRecorder Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-723\"\u003e User-programmable for +4 to +20 mA, 0 to -10 Vdc, or +1 to +5 Vdc\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-723 citation-end-723\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-722\"\u003eBuffered Transducer Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-722\"\u003e One coaxial connector per channel on the front panel and one terminal connection per channel on the rear\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-722 citation-end-722\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-721\"\u003eOutput Impedance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-721\"\u003e 100 Ω\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-721 citation-end-721\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e3. Alarms \u0026amp; Displays\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-720\"\u003eAlarm Setpoints:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-720\"\u003e Alert and Danger alarms are bi-directional and digitally adjustable from 0 to 100% of full-scale\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-720 citation-end-720\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-719\"\u003eMeter Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-719\"\u003e Non-multiplexing vertical bargraph LCD per channel; includes a third center scale for Probe Gap\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-719 citation-end-719\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-718\"\u003eOK LED:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-718\"\u003e Indicates the condition of the monitor, transducers, and field wiring\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-718 citation-end-718\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information (Suffix Codes)\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-717\"\u003eFormat: 3300\/20-AXX-BXX-CXX-DXX-EXX\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-717\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-717 citation-end-717\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-716\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eA: Full-scale Range Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-716 citation-end-716\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 25-0-25 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 30-0-30 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 40-0-40 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 50-0-50 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 75-0-75 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e11\u003c\/strong\u003e: 0.5-0-0.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: 1.0-0-1.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e13\u003c\/strong\u003e: 2.0-0-2.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-715\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eB: Transducer Input Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-715 citation-end-715\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 3300 or 7200 Proximitor® systems, 200 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 7200 11 mm (not 3300XL) Proximitor system, 100 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 7200 14 mm or 3300 HTPS Proximitor systems, 100 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 3000 Proximitor® 200 mV\/mil (Requires -18 Vdc supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 3300XL NSv and 3300 RAM Proximitor Sensor, 200 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-714\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eC: Alarm Relay Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-714 citation-end-714\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Epoxy-sealed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Hermetically-sealed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Quad Relay (Epoxy-sealed only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: Spare Monitor - No SIM\/SIRM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-713\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eD: Agency Approval Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-713 citation-end-713\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: CSA\/NRTL\/C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: ATEX self-certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-712\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eE: Safety Barrier Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-712 citation-end-712\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: None\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: External\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Internal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-711\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eField-programmable Jumper Options\u003c\/strong\u003e\u003cspan\u003e\u003cspan class=\"citation-711 citation-end-711\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-710\"\u003eDanger Relay Voting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-710\"\u003e: AND voting (factory default) or OR voting\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-710 citation-end-710\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-709\"\u003eDanger Relay Mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-709\"\u003e: Normally de-energized (factory default) or Normally energized\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-709 citation-end-709\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-708\"\u003eAlarm Time Delay\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-708\"\u003e: 0.1 sec, 1 sec, 3 sec, or 6 sec\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-708 citation-end-708\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-707\"\u003eThrust Direction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-707\"\u003e: Toward probe or Away from probe\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-707 citation-end-707\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666868400491,"sku":"3300\/20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-20-dual-thrust-position-monitor-wxm3vxeyvcp_681503f5-7659-4252-bc09-110981de32c6.jpg?v=1765449541"}],"url":"https:\/\/www.plcprotech.com\/collections\/3300-system-monitoring.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}