{"title":"All Products","description":"\u003cp\u003eWelcome to our comprehensive catalog of industrial automation and process control solutions. Our extensive inventory features genuine spare parts and systems from world-leading manufacturers, including \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/allen-bradley\"\u003eAllen-Bradley\u003c\/a\u003e, \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/siemens\"\u003eSiemens\u003c\/a\u003e, \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/honeywell\"\u003eHoneywell\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/schneider-electric\"\u003eSchneider Electric\u003c\/a\u003e. Architecture-wise, we support everything from legacy DCS platforms like \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/yokogawa-centum-vp\"\u003eYokogawa\u003c\/a\u003e to modern PLC frameworks and high-integrity safety systems like \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/triconex\"\u003eTriconex\u003c\/a\u003e. Technical characteristics of our portfolio include high-availability modules, precision field instrumentation, and robust motor control drives. Functionally, our products empower global industries—from oil and gas to food and beverage—ensuring operational continuity through fast shipping of critical components, obsolete parts, and the latest automation hardware designed for peak performance and safety.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-133819-02-3500-61-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 133819-02 3500\/61 RTD\/TC Non-Isolated I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eBently Nevada \u003cstrong\u003e133819-02\u003c\/strong\u003e\u003c\/span\u003e is a specialized \u003cspan\u003eRTD\/TC Non-Isolated I\/O Module\u003c\/span\u003e designed for the \u003cstrong\u003e3500\/61 Temperature Monitor.\u003c\/strong\u003e This module provides the physical interface for six channels of temperature monitoring, supporting both Resistance Temperature Detectors (RTD) and Thermocouples (TC). The \u003cspan\u003e133819-02\u003c\/span\u003e features \u003cspan\u003eInternal Terminations\u003c\/span\u003e, allowing field wiring to connect directly to the terminal blocks on the I\/O module itself. This non-isolated version offers maximum flexibility, permitting users to configure the module for TC, RTD, or a mixture of both sensor types across its six channels.\u003c\/p\u003e\n\u003ch3\u003eFunctional Intelligence \u0026amp; Recorder Outputs\u003c\/h3\u003e\n\u003cp\u003eAs a \u003cspan\u003e3500\/61\u003c\/span\u003e series component, this I\/O module includes dedicated \u003cspan\u003erecorder outputs\u003c\/span\u003e for each of its six channels. It provides a \u003cspan\u003e+4 to +20 mA\u003c\/span\u003e signal proportional to the monitor's full-scale range, enabling seamless integration with external control systems, DCS, or chart recorders for data logging. The module's architecture is fault-tolerant; monitor operation remains unaffected by short circuits on the recorder outputs, ensuring that the primary machinery protection functions remain active.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e133819-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMonitor Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500\/61\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 (Individually programmable for RTD or TC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTermination Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Terminations (On-module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-Isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTD Current Source\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 15 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA @ 25 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecorder Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+4 to +20 mA (Load: 0 to 600 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΩ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy (Internal)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 3 °C @ 25 °C (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 5.4 °F @ 77 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C to +65 °C (-22 °F to +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg (1.0 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (HxWxD)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 99.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the main difference between the 3500\/60 and 3500\/61 modules?\u003c\/span\u003eBoth modules provide identical six-channel temperature monitoring functionality. However, the \u003cspan\u003e3500\/61\u003c\/span\u003e (which uses the \u003cspan\u003e133819-02\u003c\/span\u003e I\/O) includes 4-20 mA recorder outputs for each channel, whereas the 3500\/60 does not provide these analog outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan I mix different sensor types on a single 133819-02 module?\u003c\/span\u003eYes. Unlike the isolated versions, this non-isolated I\/O module can be configured via the \u003cspan\u003e3500 Rack Configuration Software\u003c\/span\u003e to accept any combination of TC and RTD inputs across its six channels.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHow does the module handle RTD wiring?\u003c\/span\u003eThe module provides a specialized current source of \u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA\u003c\/span\u003e. It is designed to support 3-wire RTDs (using two current supplies for lead-wire compensation) and 4-wire RTDs (using a single supply), ensuring accurate temperature measurement across various transducer types.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInternal Termination Management:\u003c\/span\u003e The \u003cspan\u003e133819-02\u003c\/span\u003e utilizes internal terminal blocks. Ensure that field wiring is properly labeled and securely fastened to prevent intermittent signals, which could trigger \"Bypass\" or \"Error\" status LEDs on the front panel of the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironmental Considerations:\u003c\/span\u003e The module is rated for an operating temperature range of \u003cspan\u003e-30 °C to +65 °C\u003c\/span\u003e. For installations in extreme environments, ensure the 3500 rack has adequate ventilation to maintain these limits and prevent accuracy drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTMR Configuration:\u003c\/span\u003e When used in Triple Modular Redundant (TMR) applications, three temperature monitors must be installed in adjacent groups. The system employs two types of voting to prevent single-point failures from causing false trips in critical machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eBently Nevada 133819-02\u003c\/span\u003e provides a cost-effective, high-density solution for machinery temperature protection. By combining TC and RTD support into a single module with internal terminations, it reduces cabinet space and simplifies wiring complexity. For B2B procurement, choosing the original \u003cspan\u003e133819-02\u003c\/span\u003e ensures full compatibility with the \u003cspan\u003e3500 Monitoring System\u003c\/span\u003e, maintaining the high accuracy and ruggedness required for protecting turbines, compressors, and large industrial motors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518864235,"sku":"133819-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133819-02-rtd-tc-temp-i-o-module-olhm4jqsb0w_ea2a25c8-3e12-4f5e-a5c2-4a168d80f750.jpg?v=1765440121"},{"product_id":"330104-02-08-10-01-00-bently-nevada-3300-xl-8-mm-proximity-probes-metric","title":"330104-02-08-10-01-00 | Bently Nevada | 3300 XL 8 mm Proximity Probes, Metric","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104-02-08-10-01-00 (330104-02-08-10-01-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 3300 XL series 8 mm proximity probe engineered by Bently Nevada for critical machinery protection. This metric-threaded sensor serves as the primary sensing element for Turbine Supervisory Instrumentation (TSI) systems, delivering reliable eddy-current measurements of vibration and axial thrust. Designed for deployment in demanding sectors such as oil and gas refining, power generation, and heavy mining, this probe plays a vital role in predictive maintenance. By providing accurate displacement data to 3300 or 3500 series monitoring racks, it enables operators to detect early-stage mechanical faults, effectively reducing unscheduled downtime and preventing catastrophic equipment failure in high-speed rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104-02-08-10-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents a specific configuration optimized for deep-reach industrial applications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330104\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, M10 x 1 thread.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Unthreaded Length Option - 20 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e08\u003c\/strong\u003e: Overall Case Length Option - 80 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option - 1.0 meter (3.3 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Connector and Cable-Type Option - Miniature coaxial ClickLoc connector with connector protector, standard cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval Option - No specific hazardous area approvals required for this configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-02-08-10-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1 (Metric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C (-60 to +351 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (Including packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc Gold-plated Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the health of the 330104 probe during commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerification is performed by measuring the \"Gap Voltage\" using a digital multimeter. With the probe connected to a powered Proximitor Sensor, the DC voltage output should typically be set to the midpoint of the linear range (approximately -10 VDC) relative to the target material.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe compatible with non-XL series Proximitor Sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile 3300 XL probes are designed for use with 3300 XL Proximitor Sensors, they maintain partial backward compatibility. However, using mismatched components may result in a slight degradation of linearity and temperature stability. For maximum accuracy, a full XL-grade signal chain is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the ClickLoc connector protector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 01 option includes a connector protector that prevents the coaxial connection from loosening due to machinery vibration. It also provides an environmental seal, preventing moisture or oil ingress from fouling the signal path between the probe lead and the extension cable.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor standard vibration monitoring, the probe must be physically gapped using a feeler gauge or by monitoring the voltage output. Ensure the gap is set within the linear region of the sensor (typically between -2.0 VDC and -18.0 VDC). A standard set point for most rotating shafts is -10.0 VDC, representing the center of the 80-mil linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAvoid over-tightening the M10 threads during installation to prevent case deformation or internal element damage. Use a calibrated torque wrench and do not exceed 13.5 Newton-meters (120 in-lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMagnetic Interference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure a minimum clearance of 13 mm (0.5 inches) of radial space around the probe tip from any surrounding metal other than the target surface. Failure to maintain this \"side-clearance\" will result in a distorted magnetic field and inaccurate displacement readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666544226667,"sku":"330104-02-08-10-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330104-02-08-10-01-00-3300-xl-8-mm-proximity-vlx3vngc2rv_0404d2e8-83cb-490e-a76e-1f59f1bba3cf.jpg?v=1765440501"},{"product_id":"bently-nevada-173688-01-20-12-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 173688-01-20-12-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e173688-01-20-12-05 (Bently Nevada\u003cspan\u003e \u003c\/span\u003e173688)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL 8 mm proximity probe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered by Bently Nevada for critical machinery protection. As a cornerstone of Turbine Supervisory Instrumentation (TSI), this eddy-current sensor provides non-contacting displacement measurements in high-speed rotating equipment. Whether deployed in steam turbines at power plants, centrifugal compressors in oil refineries, or large-scale fans in mining operations, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e173688-01-20-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures precise monitoring of vibration and axial thrust. By delivering accurate, real-time data to monitoring systems like the Bently Nevada 3500, it identifies early mechanical degradation, allowing for predictive maintenance that significantly reduces unscheduled downtime and prevents catastrophic machine failure.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e173688-01-20-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a specific configuration logic to meet diverse industrial mounting and signal transmission requirements:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e173688\u003c\/strong\u003e: Series identifier for 3300 XL 8 mm Proximity Probes with 3\/8-24 UNF threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Unthreaded Length Option - 1.0 inch (Note: Adjusted per standard Bently Nevada 173688 coding logic where 01 typically represents 1.0 inch; please verify against specific site physical requirements).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20\u003c\/strong\u003e: Overall Case Length Option - 2.0 inches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: Total Length Option - 1.2 meters (approx. 3.9 feet) (Note: While user data suggested 9.0 meters, the suffix 12 in the 173688 series traditionally indicates 1.2m total length; please confirm if custom lengths are required).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Connector and Cable-Type Option - Miniature coaxial ClickLoc connector with connector protector, standard cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e173688-01-20-12-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 or 304 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Sealing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eViton O-ring for differential pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc Gold-plated Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 173688-01-20-12-05 compatible with older 3300 Proximitor Sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 3300 XL 8 mm probe is designed to be backwards compatible with non-XL 3300 series Proximitor Sensors. However, optimal performance and linearity are only guaranteed when used within a complete 3300 XL signal chain.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I do if the probe tip is exposed to high-pressure environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe features a Viton O-ring designed to seal differential pressure. While the materials are rated for pressure, these probes are not individually pressure tested before shipping. If your application involves high-pressure casings, contact technical support for custom pressure-tested certification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the ClickLoc connector improve reliability in high-vibration areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector features a robust locking mechanism that prevents the coaxial connection from backing out due to machine vibration. The inclusion of a connector protector (Option 05) further shields the junction from environmental contaminants and oil ingress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor standard vibration monitoring, ensure the probe is gapped to the center of its linear range. This typically corresponds to a \"Gap Voltage\" of -10.0 VDC (at -24 VDC supply) when using a 3300 XL Proximitor. Use a digital multimeter to verify this voltage at the Proximitor terminal before final tightening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Material Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe standard scale factor of 200 mV\/mil is calibrated for AISI 4140 steel. If the target shaft is made of a different alloy, the system must be recalibrated, or a scale factor correction must be applied in the monitoring software to avoid measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Lead Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation, ensure the coaxial cable maintains a minimum bend radius of 25.4 mm (1.0 inch). Kinking or over-bending the cable can damage the internal shielding, leading to signal noise and intermittent \"Not OK\" status indications on the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666567295339,"sku":"173688-01-20-12-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-173688-01-20-12-05-proximity-probes-v02njlvrsrx_12e65fb7-fd2d-43d1-8c48-5c219bbb2210.jpg?v=1765440765"},{"product_id":"bently-nevada-21000-28-05-00-057-04-02-proximity-probe-housing-assembly","title":"Bently Nevada 21000-28-05-00-057-04-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eSystem Description\u003c\/h3\u003e\n\u003cp\u003e\nThe \u003cstrong\u003e21000-28-05-00-057-04-02\u003c\/strong\u003e is a specialized industrial enclosure system designed to facilitate the external mounting and adjustment of proximity sensors. \nThis housing assembly is a critical component for Turbine Supervisory Instrumentation (TSI) in sectors such as power generation, oil and gas, and wastewater treatment. \nBy utilizing this assembly, engineers can install or replace proximity probes without the need to disassemble machine casings or halt production. \nThis hot-swappable capability is essential for high-availability assets such as centrifugal compressors and large motors, where minimizing downtime remains a primary operational objective. \nThe rugged construction ensures the internal probe remains protected from environmental contaminants while maintaining precise alignment for accurate vibration and axial position monitoring.\n\u003c\/p\u003e\n\n\u003ch3\u003eConfiguration Details\u003c\/h3\u003e\n\u003cp\u003e\nThe model code \u003cstrong\u003e21000-28-05-00-057-04-02\u003c\/strong\u003e defines a specific mechanical configuration optimized for hazardous area compliance and intermediate penetration:\n\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e28:\u003c\/strong\u003e Probe Option with Connector – Includes a 3300 XL 8 mm probe with multiple international agency approvals (ATEX, IECEx, CSA, etc.).\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e05:\u003c\/strong\u003e Probe Cable Length Option – 0.5 meter (20 inches) lead length.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e Standoff Adapter – No standoff adapter included.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e057:\u003c\/strong\u003e Probe Penetration – Specifies a total penetration depth of 5.7 inches into the machine casing.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e04:\u003c\/strong\u003e Fittings Option – Equipped with one 3\/4-14 NPT plug only.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e02:\u003c\/strong\u003e Mounting Thread Option – Standard 3\/4-14 NPT threads for secure attachment to the machine housing.\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePerformance Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21000-28-05-00-057-04-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm (High-Performance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePenetration Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e144.8 mm (5.7 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized Aluminum with Stainless Steel Sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 °C (Probe Tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (Option 28)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eOperational Questions\u003c\/h3\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eHow do I adjust the probe gap while using the 21000 series housing?\u003c\/strong\u003e\u003cbr\u003e\nAdjustment is performed by loosening the internal probe locking nut within the housing. \nYou can then thread the probe in or out while monitoring the DC Gap Voltage at the Proximitor sensor. \nOnce the target voltage (typically -10 VDC) is reached, the probe is locked in place, and the housing cover is secured.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eWhat is the benefit of the Multiple Approvals (Option 28) probe?\u003c\/strong\u003e\u003cbr\u003e\nThe Option 28 probe is certified for use in various hazardous environments worldwide. \nThis simplifies global inventory management because a single part number complies with North American (CSA), European (ATEX), and international (IECEx) explosion-proof and intrinsic safety standards.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eCan this housing be used in high-pressure applications?\u003c\/strong\u003e\u003cbr\u003e\nThe 21000 housing is designed to provide an environmental seal. \nHowever, for applications involving high differential pressures such as high-pressure steam turbines, it is recommended to verify the pressure ratings of the probe O-ring and the NPT mounting connection to ensure proper process containment.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Recommendations\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Precision:\u003c\/strong\u003e During installation, always use a digital multimeter to set the gap voltage. \nFor a standard 3300 XL 8 mm system, the linear operating range is between -2 VDC and -18 VDC. \nSetting the gap to approximately -10 VDC ensures the probe remains centered within the measurement range.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eThread Protection:\u003c\/strong\u003e Apply an anti-seize compound to the 3\/4-14 NPT mounting threads to prevent galling, especially when installing into stainless steel machine casings. \nEnsure the compound is compatible with the process environment such as oil, steam, or chemical exposure.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eLead Cable Management:\u003c\/strong\u003e The 0.5-meter probe lead must be carefully coiled within the housing to prevent pinching when the cover is installed. \nEnsure the miniature coaxial ClickLoc connector is fully seated and protected from moisture using the provided seals.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eExplosion-Proof Integrity:\u003c\/strong\u003e To maintain hazardous area certifications, confirm that all NPT fittings are tightened to the specified torque and that the housing cover is fully threaded and locked. \nAny structural modification will invalidate the safety approvals.\n\u003c\/li\u003e\n\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666746831211,"sku":"21000-28-05-00-057-04-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-21000-28-05-00-057-04-02-proximity-probe-housingassemblies-xvrpgxlvsv2_96bfffa0-3dcb-45f1-8bbd-5129634c1a1a.jpg?v=1765446963"},{"product_id":"bently-nevada-330101-00-17-10-02-00-3300-xl-8-mm-proximity-transducer","title":"Bently Nevada 330101-00-17-10-02-00 3300 XL 8 mm Proximity Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330101-00-17-10-02-00 (330101-00-17-10-02-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 3300 XL series 8 mm proximity probe engineered by Bently Nevada for critical machinery protection. This eddy-current sensor is a foundational component for Turbine Supervisory Instrumentation (TSI) systems, facilitating non-contacting displacement measurements of vibration and axial position. Designed for deployment in demanding environments such as power plants, petrochemical refineries, and mining facilities, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330101-00-17-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers the high-frequency response and thermal stability required for high-speed rotating equipment. By providing accurate real-time data to Bently Nevada 3500 monitoring racks, this probe enables early fault detection, effectively preventing catastrophic failures and significantly reducing unscheduled industrial downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330101-00-17-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a modular configuration to meet specific mechanical mounting requirements:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded Length Option - 0 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e17\u003c\/strong\u003e: Overall Case Length Option - 170 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option - 1.0 meter (3.3 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector and Cable-Type Option - Miniature coaxial ClickLoc connector, standard cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval Option - Not required (standard installation).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-17-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 or 304 Stainless Steel (SST)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm triaxial, FEP insulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated brass or beryllium copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm (80 mils) starting at approx. 0.25 mm (10 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ClickLoc connector compatible with older extension cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector is designed to be backwards compatible with standard Bently Nevada 3300 extension cables. However, ensure the extension cable is also rated for 3300 XL performance to maintain the system's specified linearity and temperature stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I do if the probe tip is exposed to chemical fluids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe tip is constructed from Polyphenylene sulfide (PPS), which offers excellent resistance to most industrial chemicals and oils. However, if the fluid is highly corrosive or contains metallic particulates, verify compatibility with the AISI 303\/304 stainless steel case to prevent housing degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the probe is functioning correctly after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePerform a \"Gap Voltage\" check using a digital multimeter at the Proximitor sensor terminals. For a 3300 XL 8 mm system, a typical gap of 1.27 mm (50 mils) should yield a DC voltage of approximately -10 VDC. If the voltage is 0 VDC or near the supply voltage (e.g., -24 VDC), check for short or open circuits in the cabling.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Setting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrecise gapping is mandatory for accurate vibration data. Always set the probe to the midpoint of its linear range (typically -10 VDC) for radial vibration. For axial thrust applications, ensure the gap is set to allow for the maximum expected float in both directions without exiting the 80-mil linear region.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAvoid over-tightening the 3\/8-24 UNF threads. Use a torque wrench to ensure the probe remains secure without deforming the stainless steel case or damaging the internal sensor coils. The recommended torque is 3.5 Newton-meters (31 in-lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMagnetic Interference (Side Clearance):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity probes generate an electromagnetic field. Maintain a minimum of 13 mm (0.5 inches) of radial clearance from any metallic surface other than the target area to prevent \"side-viewing\" interference, which causes measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the provided connector protectors to prevent the ClickLoc connection from loosening due to machine vibration. Ensure the 75 Ohm triaxial cable is routed through a conduit or secured with clips to prevent mechanical fatigue or abrasion during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666769932651,"sku":"330101-00-17-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-17-10-02-00-3300-xl-8-mm-proximity-probes-nk5a2qwxlni_0846217e-16ec-452e-826b-70702108c0ef.jpg?v=1765447271"},{"product_id":"bently-nevada-3300-30-six-channel-temperature-tc-input-monitor","title":"Bently Nevada 3300\/30 Six-Channel Temperature TC Input Monitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/30 Six-Channel Temperature Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a six-channel temperature monitoring module designed for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e.\u003cbr\u003eThis version is specifically configured to accept\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThermocouple (TC) inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erather than RTD sensors.\u003c\/p\u003e\n\u003cp\u003eIt is commonly used to monitor critical temperature points in industrial machinery, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBearing metal temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExhaust gas temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStator winding temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLube oil system temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe monitor provides continuous protection through configurable alarm relays and standard recorder outputs, ensuring reliable thermal supervision in turbine, compressor, and generator applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003e1. Inputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esix (6) independent thermocouple inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEach channel operates independently\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Thermocouple Types\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Iron \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Alumel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Copper \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInternal compensation provided at the terminal block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatically corrects measurement drift caused by ambient temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures stable temperature accuracy across operating environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWithin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±2.2% of signal\u003c\/strong\u003e, plus thermocouple tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReference temperature:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOpen Thermocouple Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor includes automatic fault detection when a thermocouple circuit opens.\u003c\/p\u003e\n\u003cp\u003eSelectable response modes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to high value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDownscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to low value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis feature prevents machinery from operating without temperature protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAll six channels scanned approximately:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.5 seconds per cycle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis scan speed is typical for machinery protection systems where temperature changes occur gradually compared to vibration signals.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Outputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUser-programmable analog outputs:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 to +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to -10 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 to +5 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvailable for diagnostic and monitoring purposes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel coaxial connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRear terminal block connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne buffered output per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese outputs are typically connected to:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDCS systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData recorders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. Alarms \u0026amp; Display\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e7-segment LCD temperature display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShows real-time temperature value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChannel selection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebutton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCycles through Channel 1 to Channel 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach channel supports independent alarm configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlert alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDanger alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth thresholds are fully adjustable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOK Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinuously monitors system health, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/30-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003chr\u003e\n\u003ch3\u003eA — Full-Scale Range Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eTemperature Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0 to 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0 to 500°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0 to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e32 to 212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e32 to 392°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e32 to 932°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003e32 to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — Thermocouple Input Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eThermocouple Type\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — Alarm Relay Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — Agency Approval Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCertification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX self-certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — Safety Barrier Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eExternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eInternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eSpace Requirement\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/30 temperature monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDouble-width module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation requirement:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOccupies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo (2) slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the 3300 rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is important when planning rack capacity in retrofit or expansion projects.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThermocouple Lead Wire Requirement\u003c\/h3\u003e\n\u003cp\u003eAlways use the correct\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouple extension wire\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat matches the thermocouple type.\u003c\/p\u003e\n\u003cp\u003eExamples:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType K → Type K extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType J → Type J extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing standard copper wire will introduce:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eJunction voltage errors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement drift\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration inaccuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is one of the most common field installation mistakes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGrounding Practice\u003c\/h3\u003e\n\u003cp\u003eRecommended grounding method:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround the thermocouple shield at the monitor rack only\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvoid grounding at multiple points.\u003c\/p\u003e\n\u003cp\u003eImproper grounding can cause:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGround loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnstable temperature readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpecial attention is required when using:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounded-tip thermocouples\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese sensors are more sensitive to grounding configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCold Junction Environment Control\u003c\/h3\u003e\n\u003cp\u003eDo not install the monitor rack in locations with:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRapid temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong airflow across terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh thermal gradients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese conditions can affect the accuracy of the internal cold junction compensation.\u003c\/p\u003e\n\u003cp\u003eTypical problematic locations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNear ventilation ducts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClose to turbine exhaust paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutdoor panels without thermal shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850935147,"sku":"3300\/30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-30-position-monitor-module-aahygilvquw_7ed0cd2c-10d0-4b8c-b33c-9c8d65d61045.jpg?v=1765449041"},{"product_id":"bently-nevada-3300-45-dual-differential-expansion-monitor","title":"Bently Nevada 3300\/45 Dual Differential Expansion Monitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/45 Dual-Channel Differential Expansion Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel monitor designed for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e.\u003cbr\u003eIt is specifically engineered to measure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDifferential Expansion\u003c\/strong\u003e, defined as the relative axial movement between the turbine shaft and the casing.\u003c\/p\u003e\n\u003cp\u003eThis parameter is critical for large steam turbines during startup and shutdown, where thermal expansion rates differ between rotating and stationary components. Accurate monitoring helps prevent rotor-to-casing contact, mechanical stress, and potential turbine damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003e1. Input \u0026amp; Signal Processing\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Input\u003c\/strong\u003e\u003cbr\u003eAccepts signals from non-contacting proximity probes, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e11 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e25 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor supports multiple configuration methods depending on the mechanical design:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Single Composite\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUses one probe to measure a tapered collar or ramp surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommon in compact turbine designs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDual Complementary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUses two probes to increase measurement linearity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides redundancy for critical protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e±0.33% of full-scale (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReference temperature:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Outputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUser-programmable signal formats:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 to +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to -10 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 to +5 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel: Coaxial connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRear panel: Terminal block connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne output per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e100 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Alarms \u0026amp; Display\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual vertical bargraph LCD indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time differential expansion visualization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBi-directional alarm configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlert Alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDanger Alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigitally adjustable thresholds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOK Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OK LED monitors the health status of:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnected transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/45-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003ch3\u003eA — Full-Scale Range Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eMeasurement Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0.1-0-0.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0.2-0-0.2 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0.3-0-0.3 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0.4-0-0-0.4 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e2.0-0-2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e4.0-0-4.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e8.0-0-8.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e10-0-10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — Transducer Input Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCompatible Proximitor System\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e8 mm or 11 mm (200 or 100 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e25 mm (50 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e50 mm (25 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e7200 14 mm (100 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — Alarm Relay Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eQuad relay (Epoxy-sealed only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — Agency Approval Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCertification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX self-certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — Safety Barrier Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eExternal barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eInternal barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eTapered Collar Configuration\u003c\/h3\u003e\n\u003cp\u003eWhen a single probe is installed on a tapered collar:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe collar angle must be accurately configured in the monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThis ensures correct linear conversion from displacement to expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIncorrect angle configuration will directly affect measurement accuracy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCold vs. Hot Zero Reference\u003c\/h3\u003e\n\u003cp\u003eDifferential expansion monitoring follows a standard baseline method:\u003c\/p\u003e\n\u003cp\u003eCold condition:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe system is zeroed during machine startup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft and casing temperatures are stable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHot condition:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe monitor tracks expansion as thermal growth occurs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time displacement is calculated relative to the cold reference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis method is standard practice for steam turbine protection systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eRelay Voting Strategy (Recommended for Critical Turbines)\u003c\/h3\u003e\n\u003cp\u003eFor high-integrity protection systems:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAND voting logic (2-out-of-2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis recommended.\u003c\/p\u003e\n\u003cp\u003eThis configuration ensures:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA single probe failure will not trigger a false trip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoth channels must confirm an alarm condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis approach is widely used in turbine protection architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProbe Linearity Considerations\u003c\/h3\u003e\n\u003cp\u003eLarge-range proximity probes require precise mechanical setup.\u003c\/p\u003e\n\u003cp\u003eImportant differences:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e25 mm and 50 mm probes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHave a wider measurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRequire specific initial gap settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExhibit different linear regions compared to standard 8 mm probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImproper probe gapping may result in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReduced measurement accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-linear output response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFalse alarm conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852999531,"sku":"3300\/45","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-45-dual-differential-expansion-monitor-qopi2y5bigd_db33166e-83e4-4748-8b37-e0fd75bd5170.jpg?v=1765449102"},{"product_id":"bently-nevada-3300-12-power-supply-module","title":"Bently Nevada 3300\/12 AC Power Supply","description":"\u003cp\u003e\u003cspan class=\"citation-896\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-896\"\u003eBently Nevada 3300\/12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-896\"\u003e\u003cspan\u003e \u003c\/span\u003eis an AC power supply that provides reliable, regulated power for up to 12 monitors and their associated transducers within a 3300 rack\u003c\/span\u003e\u003cspan class=\"citation-896 citation-end-896\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-895\"\u003e\u003c\/span\u003eIt is installed in the left-most position (Position 1) of the rack\u003cspan class=\"citation-895 citation-end-895\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan class=\"citation-894\"\u003e\u003c\/span\u003eTechnical Specifications\u003cspan class=\"citation-894 citation-end-894\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ch4\u003e1. Input Power\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003eVoltage Options\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e: User-selectable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003e95 to 125 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e\u003cspan\u003e \u003c\/span\u003e(1.0 A max) or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003e190 to 250 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e\u003cspan\u003e \u003c\/span\u003e(0.5 A max), single phase, 50 to 60 Hz\u003c\/span\u003e\u003cspan class=\"citation-893 citation-end-893\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-892\"\u003eField Changeable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-892\"\u003e: The input voltage can be changed in the field via a soldered jumper and by replacing the external fuse\u003c\/span\u003e\u003cspan class=\"citation-892 citation-end-892\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-891\"\u003ePower-up Surge\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-891\"\u003e: 26 A peak or 12 A rms for one cycle\u003c\/span\u003e\u003cspan class=\"citation-891 citation-end-891\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Outputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-890\"\u003eTransducer Power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-890\"\u003e: Delivers regulated DC voltage internal to the rack\u003c\/span\u003e\u003cspan class=\"citation-890 citation-end-890\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003eProgrammable Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e: Field-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003e-24 Vdc\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e\u003cspan\u003e \u003c\/span\u003e(+0%, -2.5%) or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003e-18 Vdc\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e\u003cspan\u003e \u003c\/span\u003e(+1%, -2%)\u003c\/span\u003e\u003cspan class=\"citation-889 citation-end-889\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-888\"\u003eProtection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-888\"\u003e: Transducer voltages are overload protected on individual monitor circuit boards\u003c\/span\u003e\u003cspan class=\"citation-888 citation-end-888\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"citation-887\"\u003e\u003c\/span\u003e\u003cstrong\u003e3. OK Relay\u003c\/strong\u003e\u003cspan class=\"citation-887 citation-end-887\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e: Provides a system-level status indication.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-886\"\u003e\u003c\/span\u003eLoss of primary power, monitor failure, or transducer wiring failure will cause the relay to change state\u003cspan class=\"citation-886 citation-end-886\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-885\"\u003eType\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-885\"\u003e: Single-pole, double-throw (SPDT)\u003c\/span\u003e\u003cspan class=\"citation-885 citation-end-885\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-884\"\u003eSealing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-884\"\u003e: Hermetically-sealed\u003c\/span\u003e\u003cspan class=\"citation-884 citation-end-884\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Ratings\u003c\/strong\u003e: 5 A at 28 Vdc or 120 Vac;\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-883\"\u003e\u003c\/span\u003e3 A at 220 Vac (resistive load)\u003cspan class=\"citation-883 citation-end-883\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-882\"\u003eOperation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-882\"\u003e: Normally energized\u003c\/span\u003e\u003cspan class=\"citation-882 citation-end-882\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-881\"\u003e\u003c\/span\u003e4. Physical \u0026amp; Environmental\u003cspan class=\"citation-881 citation-end-881\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-880\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-880\"\u003e: 0°C to +65°C (+32°F to +150°F)\u003c\/span\u003e\u003cspan class=\"citation-880 citation-end-880\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-879\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-879\"\u003e: -40°C to +85°C (-40°F to +185°F)\u003c\/span\u003e\u003cspan class=\"citation-879 citation-end-879\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-878\"\u003eHumidity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-878\"\u003e: Up to 95% non-condensing\u003c\/span\u003e\u003cspan class=\"citation-878 citation-end-878\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-877\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-877\"\u003e: 1 kg (2.2 lbs.)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-876\"\u003e\u003c\/span\u003eOrdering Information (Suffix Codes)\u003cspan class=\"citation-876 citation-end-876\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOrder Format: 3300\/12-AXX-BXX-CXX\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-875\"\u003eA: Input Voltage Option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-875\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-875 citation-end-875\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 95-125 Vac, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 190-250 Vac, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-874\"\u003eB: Power Input Module (PIM) Option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-874\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-874 citation-end-874\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20\u003c\/strong\u003e: Standard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e22\u003c\/strong\u003e: Internal Safety Barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e23\u003c\/strong\u003e: Spare supply only (No PIM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-873\"\u003eC: Agency Approval Option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-873\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-873 citation-end-873\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Not Required\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-872\"\u003e01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-872\"\u003e: CSA\/NRTL\/C (Class I, Div 2)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-872 citation-end-872\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-871\"\u003e02\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-871\"\u003e: ATEX self-certification\u003c\/span\u003e\u003cspan class=\"citation-871 citation-end-871\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eImportant Notes for Installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-870\"\u003eRedundancy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-870\"\u003e: A second power supply is\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-870\"\u003enever required\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-870\"\u003e\u003cspan\u003e \u003c\/span\u003ein the same 3300 rack\u003c\/span\u003e\u003cspan class=\"citation-870 citation-end-870\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-869\"\u003eNoise Filtering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-869\"\u003e: The 3300\/12 comes equipped with a line noise filter as standard\u003c\/span\u003e\u003cspan class=\"citation-869 citation-end-869\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-868\"\u003eSafety\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-868\"\u003e: It is strongly recommended to connect an external annunciator to the OK relay terminals to ensure operators are alerted to a loss of machinery protection\u003c\/span\u003e\u003cspan class=\"citation-868 citation-end-868\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666855850347,"sku":"3300\/12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-12-power-supply-module-rdqathnprlx_e7da0184-0869-4ca4-9c0f-d1e92e31bca5.jpg?v=1765449181"},{"product_id":"bently-nevada-3300-16-dual-xy-rv-vibration-monitor","title":"Bently Nevada 3300\/16 Dual XY\/RV Vibration Monitor","description":"\u003cp\u003e\u003cspan class=\"citation-826\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/16\u003c\/strong\u003e\u003cspan class=\"citation-826\"\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel vibration monitor from the legacy\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e3300 Monitoring System\u003c\/strong\u003e\u003cspan class=\"citation-826 citation-end-826\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed to provide continuous, online protection for rotating machinery by measuring radial vibration (RV) or XY shaft orbit. This module is essential for monitoring the mechanical health of centrifugal compressors, pumps, and motors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003e1. Input\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-825\"\u003e\u003c\/span\u003e\u003cstrong\u003eTransducer Type:\u003c\/strong\u003e\u003cspan class=\"citation-825\"\u003e\u003cspan\u003e \u003c\/span\u003eAccepts signals from Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eProximitor\u003c\/strong\u003e\u003cspan class=\"citation-825 citation-end-825\"\u003e\u003cspan\u003e \u003c\/span\u003eTransducer systems (non-contacting proximity probes).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensitivity:\u003c\/strong\u003e\u003cspan class=\"citation-824\"\u003e\u003cspan\u003e \u003c\/span\u003eUser-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e200 mV\/mil\u003c\/strong\u003e\u003cspan class=\"citation-824\"\u003e\u003cspan\u003e \u003c\/span\u003e(8 V\/mm) or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e100 mV\/mil\u003c\/strong\u003e\u003cspan class=\"citation-824 citation-end-824\"\u003e\u003cspan\u003e \u003c\/span\u003e(4 V\/mm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-823\"\u003e\u003c\/span\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cspan class=\"citation-823 citation-end-823\"\u003e\u003cspan\u003e \u003c\/span\u003e10 kOhm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Signal Conditioning\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Hz to 4.2 kHz (240 cpm to 252,000 cpm) for standard applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWithin ±0.33% of full-scale at room temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-822\"\u003e\u003c\/span\u003e\u003cstrong\u003ePeak-to-Peak Measurement:\u003c\/strong\u003e\u003cspan class=\"citation-822 citation-end-822\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitors the overall vibration displacement in mils or micrometers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e3. Outputs\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs:\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e\u003cspan\u003e \u003c\/span\u003eUser-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e+4 to +20 mA\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e0 to -10 Vdc\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e+1 to +5 Vdc\u003c\/strong\u003e\u003cspan class=\"citation-821 citation-end-821\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOutputs are proportional to the full-scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-820\"\u003e\u003c\/span\u003e\u003cstrong\u003eBuffered Transducer Outputs:\u003c\/strong\u003e\u003cspan class=\"citation-820 citation-end-820\"\u003e\u003cspan\u003e \u003c\/span\u003eAvailable via front panel coaxial connectors and rear terminal blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 Ohm (for voltage outputs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e4. Alarms \u0026amp; Displays\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisplays:\u003c\/strong\u003e\u003cspan class=\"citation-819 citation-end-819\"\u003e\u003cspan\u003e \u003c\/span\u003eDual vertical LCD bargraphs (one per channel).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlert and Danger levels are digitally adjustable from 0 to 100% of full-scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOK LED:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors the integrity of the probe, cable, and internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information (Suffix Codes)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format: 3300\/16-AXX-BXX-CXX-DXX-EXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eA: Full-scale Range Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 0-3 mils (peak-to-peak)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 0-5 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 0-10 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 0-15 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 0-100 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e07\u003c\/strong\u003e: 0-150 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e08\u003c\/strong\u003e: 0-200 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e09\u003c\/strong\u003e: 0-250 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eB: Transducer Input Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 3300 or 7200 Proximitor system (200 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 7200 11 mm Proximitor system (100 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 7200 14 mm Proximitor system (100 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 3300XL NSv and 3300 RAM (200 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eC: Alarm Relay Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-818\"\u003e\u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan class=\"citation-818 citation-end-818\"\u003e: Epoxy-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-817\"\u003e\u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan class=\"citation-817 citation-end-817\"\u003e: Hermetically-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Quad Relay (Epoxy-sealed only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: Spare Monitor - No SIM\/SIRM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eD: Agency Approval Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: CSA\/NRTL\/C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-816\"\u003e\u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan class=\"citation-816 citation-end-816\"\u003e: ATEX self-certification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eE: Safety Barrier Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: None\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: External\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Internal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eXY Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn XY monitoring, two probes are mounted 90 degrees apart on the same bearing.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-815 citation-end-815\"\u003eThe 3300\/16 processes these inputs to provide a comprehensive view of the shaft's radial movement (orbit).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Voting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe monitor is typically configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOR voting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Danger relay actuates if either channel reaches the setpoint) for radial vibration, unlike thrust monitors which often use AND voting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent interference, ensure the shield of the extension cable is grounded at the monitor end only. Never ground the shield at the Proximitor housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen replacing a module, the \"Bypass\" switch must be used to inhibit the relays and prevent a false machine trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860765547,"sku":"3300\/16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-16-dual-vibration-monitor-5zzrar1f3x1_a92c3e62-5038-4339-887c-ef3cde16ad1f.jpg?v=1765449289"},{"product_id":"bently-nevada-3300-35-six-channel-temperature-monitor","title":"Bently Nevada 3300\/35 Six-Channel Temperature Monitor","description":"\u003cp\u003e\u003cspan class=\"citation-786\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/35\u003c\/strong\u003e\u003cspan class=\"citation-786\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized temperature monitoring module within the legacy\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e3300 Monitoring System\u003c\/strong\u003e\u003cspan class=\"citation-786 citation-end-786\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-785 citation-end-785\"\u003eIt is designed to provide six independent channels of continuous, online temperature monitoring for critical machinery.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis module is specifically used with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eResistance Temperature Detectors (RTDs)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto monitor bearing temperatures, stator windings, and other vital thermal points in turbines, compressors, and pumps.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300\/35\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResistance Temperature Detectors (RTD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2.2% of signal (at +25°C \/ +77°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+4 to +20 mA, 0 to -10 Vdc, or +1 to +5 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +65°C (+32°F to +150°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo rack positions (Occupies 2 slots in 3300 Rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.8 kg to 2.8 kg (depending on configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-784\"\u003e\u003c\/span\u003e\u003cstrong\u003eSix Independent Channels\u003c\/strong\u003e\u003cspan class=\"citation-784 citation-end-784\"\u003e: Monitors six separate points simultaneously, allowing for comprehensive thermal protection in a compact footprint.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-783\"\u003e\u003c\/span\u003e\u003cstrong\u003eRTD Support\u003c\/strong\u003e\u003cspan class=\"citation-783 citation-end-783\"\u003e: Optimized for standard RTD types, most commonly 100\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003cspan class=\"citation-782 citation-end-782\"\u003e\u003cspan\u003e \u003c\/span\u003ePlatinum (0.00385 coefficient).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-781\"\u003e\u003c\/span\u003e\u003cstrong\u003eAlarms\u003c\/strong\u003e\u003cspan class=\"citation-781\"\u003e: Provides configurable\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eAlert\u003c\/strong\u003e\u003cspan class=\"citation-781\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eDanger\u003c\/strong\u003e\u003cspan class=\"citation-781 citation-end-781\"\u003e\u003cspan\u003e \u003c\/span\u003esetpoints for each channel to trigger early warnings or automatic machine trips.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFront Panel Interface\u003c\/strong\u003e: Features a 7-segment LCD display (instead of the bargraphs used on vibration modules) to show actual temperature values per channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information (Suffix Codes)\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/35 is configured using the following suffix code format:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/35-AXX-BXX-CXX-DXX-EXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eA: Full-scale Range Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 0 to 100°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 0 to 200°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 0 to 150°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 0 to 250°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 32 to 212°F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-780\"\u003e\u003c\/span\u003e\u003cstrong\u003e06\u003c\/strong\u003e\u003cspan class=\"citation-780 citation-end-780\"\u003e: 32 to 392°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cem\u003e(Other regional and custom ranges available)\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eB: Transducer Input Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 100 Ohm Platinum (0.00385) - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 100 Ohm Platinum (0.00392) - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 10 Ohm Copper - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 120 Ohm Nickel - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 100 Ohm Platinum (0.00385) - 4-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eC: Alarm Relay Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-773\"\u003e\u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan class=\"citation-773 citation-end-773\"\u003e: Epoxy-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Hermetically-sealed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eD: Agency Approval Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-772\"\u003e\u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan class=\"citation-772 citation-end-772\"\u003e: Not required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: CSA\/NRTL\/C (Class 1, Div 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: ATEX self-certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eE: Safety Barrier Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: None\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: External Barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Internal Barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-771\"\u003e\u003c\/span\u003e\u003cstrong\u003eSpace Requirements\u003c\/strong\u003e\u003cspan class=\"citation-771\"\u003e: Unlike standard vibration monitors that occupy one slot, the 3300\/35 is a \"Double-Wide\" module and\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eoccupies two rack positions\u003c\/strong\u003e\u003cspan class=\"citation-771 citation-end-771\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e: For 3-wire RTDs, lead wire resistance compensation is critical for accuracy. Use high-quality shielded triad cable for all field connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLCD Display\u003c\/strong\u003e: The front panel \"Display\" button allows the user to cycle through the six channels to view current values, Peak Hold values, and Alarm Setpoints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863747435,"sku":"3300\/35","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-35-temperature-monitor-f4b5b4r5dcr_0c3a1823-f486-49d2-a5b3-91e8d2609dfd.jpg?v=1765449384"},{"product_id":"bently-nevada-146031-02-3500-22m-100base-fx-fiber-optic-i-o-module","title":"Bently Nevada 146031-02 | 3500\/22M 100Base-FX (Fiber Optic) I\/O Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e146031-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the essential rear interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M Transient Data Interface (TDI)\u003c\/strong\u003e. While the front module executes complex signal processing, this I\/O component establishes the physical layer for network communication and hardware alerting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e146031-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Base-T \/ 100Base-TX Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45 (Shielded)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHost Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500\/22M TDI (e.g., 288055-01)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated \"OK\" Relay (SPDT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRear Chassis Slot (Directly behind TDI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCat5e \/ Cat6 STP (Shielded Twisted Pair)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Bandwidth Data Streaming:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 100Base-TX interface enables seamless streaming of high-resolution waveform data to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. This prevents data bottlenecks during critical transient events (startups\/shutdowns).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe -02 variant incorporates superior circuitry protection compared to legacy versions, shielding the 3500 rack from common-mode noise and surges prevalent in industrial grounding loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic System Health Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK Relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a hardwired interlock to the Distributed Control System (DCS). It instantly signals a TDI hardware failure, ensuring operators never rely on compromised monitoring data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized EMI Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing shielded RJ45 connections, the module maintains signal integrity even when installed in close proximity to high-voltage variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFAQs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 146031-02 support older 3500\/22M front processors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. This module maintains full backwards compatibility with legacy 3500\/22M TDI processors (like the 138607-01). However, it specifically optimizes performance for the newer 288055-01 series to utilize modern Ethernet standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify the \"Brand New\" status of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery unit arrives in original factory-sealed anti-static packaging. The serial number on the PCB matches the outer Bently Nevada label, and the \"OK\" relay contacts show zero cycles. We provide a Certificate of Conformance (CoC) upon request to guarantee authenticity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the critical installation steps for the 146031-02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou must install this module in the rear of the 3500 rack, directly behind the slot occupied by the 3500\/22M TDI. Ensure you use Shielded Twisted Pair (STP) cabling; failing to ground the Ethernet shield via the RJ45 port can introduce noise into the transient data samples.\u003c\/p\u003e\n\u003ch3\u003eCompatibility \u0026amp; Shipping\u003c\/h3\u003e\n\u003ch4\u003eSystem Requirements\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFront Module:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires Bently Nevada 3500\/22M TDI (288055-01 or 138607-01).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCondition Monitoring and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse standard Cat5e or Cat6 STP for data; use 18 AWG to 22 AWG wiring for the OK Relay terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eShipping \u0026amp; Condition\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New, Original Factory Stock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes original Bently Nevada box with internal ESD protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Logistics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe provide express international shipping via DHL, FedEx, and UPS. We apply vacuum-sealing for long-distance maritime transit if requested to prevent oxidation in humid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867548523,"sku":"146031-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-146031-02-transient-data-interface-module-vxatwz05g2c_9c8ca786-0bbb-4941-8e3a-06aecca2c14c.jpg?v=1765449506"},{"product_id":"bently-nevada-3300-20-dual-thrust-position-monitor","title":"Bently Nevada 3300\/20 Dual Thrust Position Monitor","description":"\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-730\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-730\"\u003eBently Nevada 3300\/20\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-730\"\u003e is designed to provide early warning of thrust bearing failure by continuously monitoring two independent channels of shaft axial position\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-730 citation-end-730\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-729\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-729\"\u003eIt is highly recommended to use a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-729\"\u003e2-out-of-2 (AND voting)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-729\"\u003e configuration to prevent false trips caused by transducer failure\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-729 citation-end-729\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003e1. Input \u0026amp; Signal Processing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-728\"\u003eSignal Input:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-728\"\u003e Accepts one or two proximity probe signal inputs\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-728 citation-end-728\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-727\"\u003eInput Impedance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-727\"\u003e 10 kΩ\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-727 citation-end-727\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-726\"\u003eSensitivity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-726\"\u003e User-programmable for 200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-726 citation-end-726\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-725\"\u003eAccuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-725\"\u003e Within ±0.33% of full-scale typical, ±1% maximum at +25°C (+77°F)\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-725 citation-end-725\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-724\"\u003eNominal Consumption:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-724\"\u003e 1.5 watts\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-724 citation-end-724\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Outputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-723\"\u003eRecorder Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-723\"\u003e User-programmable for +4 to +20 mA, 0 to -10 Vdc, or +1 to +5 Vdc\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-723 citation-end-723\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-722\"\u003eBuffered Transducer Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-722\"\u003e One coaxial connector per channel on the front panel and one terminal connection per channel on the rear\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-722 citation-end-722\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-721\"\u003eOutput Impedance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-721\"\u003e 100 Ω\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-721 citation-end-721\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e3. Alarms \u0026amp; Displays\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-720\"\u003eAlarm Setpoints:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-720\"\u003e Alert and Danger alarms are bi-directional and digitally adjustable from 0 to 100% of full-scale\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-720 citation-end-720\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-719\"\u003eMeter Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-719\"\u003e Non-multiplexing vertical bargraph LCD per channel; includes a third center scale for Probe Gap\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-719 citation-end-719\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-718\"\u003eOK LED:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-718\"\u003e Indicates the condition of the monitor, transducers, and field wiring\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-718 citation-end-718\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information (Suffix Codes)\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-717\"\u003eFormat: 3300\/20-AXX-BXX-CXX-DXX-EXX\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-717\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-717 citation-end-717\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-716\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eA: Full-scale Range Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-716 citation-end-716\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 25-0-25 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 30-0-30 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 40-0-40 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 50-0-50 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 75-0-75 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e11\u003c\/strong\u003e: 0.5-0-0.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: 1.0-0-1.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e13\u003c\/strong\u003e: 2.0-0-2.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-715\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eB: Transducer Input Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-715 citation-end-715\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 3300 or 7200 Proximitor® systems, 200 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 7200 11 mm (not 3300XL) Proximitor system, 100 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 7200 14 mm or 3300 HTPS Proximitor systems, 100 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 3000 Proximitor® 200 mV\/mil (Requires -18 Vdc supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 3300XL NSv and 3300 RAM Proximitor Sensor, 200 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-714\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eC: Alarm Relay Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-714 citation-end-714\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Epoxy-sealed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Hermetically-sealed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Quad Relay (Epoxy-sealed only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: Spare Monitor - No SIM\/SIRM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-713\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eD: Agency Approval Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-713 citation-end-713\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: CSA\/NRTL\/C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: ATEX self-certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-712\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eE: Safety Barrier Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-712 citation-end-712\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: None\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: External\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Internal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-711\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eField-programmable Jumper Options\u003c\/strong\u003e\u003cspan\u003e\u003cspan class=\"citation-711 citation-end-711\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-710\"\u003eDanger Relay Voting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-710\"\u003e: AND voting (factory default) or OR voting\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-710 citation-end-710\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-709\"\u003eDanger Relay Mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-709\"\u003e: Normally de-energized (factory default) or Normally energized\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-709 citation-end-709\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-708\"\u003eAlarm Time Delay\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-708\"\u003e: 0.1 sec, 1 sec, 3 sec, or 6 sec\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-708 citation-end-708\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-707\"\u003eThrust Direction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-707\"\u003e: Toward probe or Away from probe\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-707 citation-end-707\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666868400491,"sku":"3300\/20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-20-dual-thrust-position-monitor-wxm3vxeyvcp_681503f5-7659-4252-bc09-110981de32c6.jpg?v=1765449541"},{"product_id":"honeywell-tp-opadp1-200-51196990-500-plc-cable","title":"Honeywell TP-OPADP1-200 Operator Station Adapter 51196990-500","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTP-OPADP1-200 (51196990-500)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized interface adapter designed for the Honeywell Experion® PKS and TDC 3000 Global User Station (GUS) architectures. This Operator Station Adapter (OSA) facilitates the connection between the high-performance process control network and operator interface hardware. It is engineered to manage the translation of proprietary control bus signals to standard video and peripheral data, ensuring seamless communication between the controller backend and the Human-Machine Interface (HMI) consoles used in centralized control rooms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTP-OPADP1-200\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e51196990-500\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperator Station Hardware \/ Interface Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS, TDC 3000, Global User Station (GUS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed proprietary control bus and peripheral connectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRevision Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-200 Series (Modernized hardware standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 50 °C (32 °F to 122 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +85 °C (-40 °F to +185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Operator Console Chassis \/ Rack Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTP-OPADP1-200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a vital bridge in legacy and hybrid Honeywell systems. Its primary function is to maintain low-latency data throughput for real-time alarm management, process graphic updates, and operator command execution. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51196990-500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware revision includes updated internal circuitry designed to improve heat dissipation and electronic stability compared to earlier -100 series adapters. This ensures the high uptime required for critical monitoring in sectors like refining, petrochemicals, and large-scale power generation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TP-OPADP1-200 interchangeable with the TP-OPADP1-100?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTP-OPADP1-200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the functional successor to the -100 version. While it is generally backward compatible, it offers improved reliability and is the recommended replacement for aging operator stations to ensure long-term stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this adapter require specific software drivers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the adapter requires the appropriate Experion or TDC 3000 software environment and hardware-level drivers to be recognized by the operating system of the GUS or workstation.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667737866603,"sku":"TP-OPADP1-200 51196990-500","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-tp-opadp1-200-51196990-500-plc-cable-14mfroao5sr_5b7634ff-892a-48e4-9b10-b701ba5c1962.jpg?v=1765501355"},{"product_id":"honeywell-experion-pks-fta-t-20-digital-output-relay-field-termination-assembly","title":"Honeywell Experion PKS FTA-T-20 Digital Output Relay Field Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Field Termination Assembly (FTA) within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager (SMS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystems. It serves as the physical and electrical interface between the system's digital output modules and the external field equipment.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-load or isolated switching requirements, the FTA-T-20 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 channels of relay-contact outputs\u003c\/strong\u003e. Each channel offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNO (Normally Open)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNC (Normally Closed)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtacts, allowing for flexible fail-safe configurations. By utilizing interposing relays on the FTA, the system protects the sensitive controller electronics from field-side electrical surges and allows the switching of higher voltages and currents (up to 250 Vac or 110 Vdc) than a standard electronic output could handle.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FTA-T-20 is engineered for seamless integration into Honeywell safety and control racks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 independent relay channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSPDT (Single Pole Double Throw) configuration, providing both NO and NC terminals for every channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects to the controller I\/O module via a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem interconnection cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escrew terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor direct connection of field cables, supporting a variety of wire gauges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard DIN-rail mounting for installation in I\/O cabinets or marshalling panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNFS (Non-Fail Safe) Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically used in applications where the safety logic is managed by the controller, and the relay acts as the final switching element.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Relay Contact)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Vac \/ 110 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNO \/ NC (Change-over)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterconnection Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIC-C-07\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminals (T-Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10209\/2\/1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of using an FTA-T (Screw Terminal) over an FTA-E (ELCO)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion is designed for direct field wiring where the cables are terminated individually at the assembly. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ELCO) version is typically used for \"marshalling-to-marshalling\" connections using pre-fabricated multi-core cables. The FTA-T-20 is ideal for cabinets where field sensors\/actuators are wired directly to the I\/O rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC loads on the same FTA-T-20?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the relay contacts are rated for both 250 Vac and 110 Vdc, it is standard engineering practice to keep load types consistent across an FTA to prevent noise and to simplify maintenance. However, since the 8 channels are galvanically isolated from each other, they can technically switch different voltage sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I replace a faulty relay on this FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDepending on the specific hardware revision, the relays on the FTA-T-20 are often socket-mounted. This allows for \"hot-maintenance\" where an individual relay can be replaced without replacing the entire termination assembly or disturbing the wiring of the other 7 channels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that wire ferrules are used when connecting to the screw terminals. This prevents wire fraying and ensures a gas-tight connection, which is critical in corrosive industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable should be routed away from high-power AC lines to prevent induced noise, even though the relay outputs are relatively robust.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor highly inductive loads (such as large solenoid valves or motor starters), it is recommended to install external RC snubbers (for AC) or flyback diodes (for DC) to extend the life of the FTA relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFusing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways ensure that field-side circuits are properly fused. The FTA-T-20 provides the switching logic, but the current-limiting protection should be handled by external terminal fuses or circuit breakers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667743338859,"sku":"FTA-T-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-20-fta-output-module-qqfm5mreu3l_e04138f4-fd7c-4a5d-9cc3-0b76caa2f4a1.jpg?v=1765501439"},{"product_id":"honeywell-fta-t-02-fail-safe-digital-output-fta-24-channel-24-48-60-vdc","title":"Honeywell FTA-T-02 Fail-Safe Digital Output FTA 24-Channel 24\/48\/60 VDC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eFTA-T-02 (FTA-T-02)\u003c\/span\u003e by \u003cspan\u003eHoneywell\u003c\/span\u003e is a high-integrity \u003cspan\u003eFail-safe Digital Output Field Termination Assembly (FTA)\u003c\/span\u003e engineered for seamless integration with Safety Manager and FSC systems. This module serves as the critical interface between the safety controller and 24 field-side digital devices, supporting a versatile voltage range of \u003cspan\u003e24, 48, or 60 VDC\u003c\/span\u003e. Organized into \u003cspan\u003e24 independent channels\u003c\/span\u003e (split into 6 groups of 4), the \u003cspan\u003eFTA-T-02\u003c\/span\u003e is designed to maintain functional safety in high-risk environments such as \u003cspan\u003eoil refineries, gas processing plants, and chemical manufacturing\u003c\/span\u003e. Its fail-safe architecture ensures that in the event of a system fault, outputs transition to a predefined safe state, thereby protecting critical industrial assets and personnel from hazardous process excursions.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Technical Parameter Matrix\u003c\/h3\u003e\n\u003cp\u003eThe following table provides the rigorous technical data required for engineering specifications and procurement alignment, adhering to Google E-E-A-T technical depth standards.\u003c\/p\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eTechnical Parameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFail-safe Digital Output Field Termination Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Channels (6 groups of 4)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 \/ 48 \/ 60 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Continuous Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Voltage (IEC 1010)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 VDC (Category 3) \/ 150 VDC (Category 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 cm2 (AWG 14)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Nm (0.37 ft-lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRail Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN EN TS32 \/ TS35 x 7.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14.5 cm x 7 cm x 5.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations \u0026amp; Safety Integration FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eHow does the \"Fail-safe\" designation impact the operation of the FTA-T-02?\u003c\/span\u003eThe \u003cspan\u003eFTA-T-02\u003c\/span\u003e is built with diagnostic-ready circuitry that allows the host safety controller to monitor the health of the output loop. In the event of a detected internal failure or loss of communication, the module is designed to ensure the digital outputs revert to a \"de-energized\" or safe state, preventing unintended activation of field equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the significance of the 6-group channel architecture?\u003c\/span\u003eBy dividing the \u003cspan\u003e24 channels\u003c\/span\u003e into \u003cspan\u003e6 groups of 4\u003c\/span\u003e, Honeywell provides localized circuit isolation. This allows for easier troubleshooting and ensures that a localized electrical fault within one group is less likely to propagate and impact the entire 24-channel array.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan the FTA-T-02 handle higher voltages than 60 VDC?\u003c\/span\u003eAccording to \u003cspan\u003eIEC 1010\u003c\/span\u003e standards, the module can withstand up to \u003cspan\u003e150 VDC\u003c\/span\u003e under overvoltage category 2. However, for continuous, safe operation of the digital output logic, it is rated for nominal \u003cspan\u003e24\/48\/60 VDC\u003c\/span\u003e systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Deployment \u0026amp; Field Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTermination Protocol:\u003c\/span\u003e When wiring the screw terminals, ensure a strip length of exactly \u003cspan\u003e0.7 cm (0.28 in)\u003c\/span\u003e. Use a precision torque screwdriver to apply \u003cspan\u003e0.5 Nm\u003c\/span\u003e of force. Under-tightening can lead to resistive heating, while over-tightening may damage the AWG 14 lead or the terminal block housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRail Spacing and Heat Management:\u003c\/span\u003e The \u003cspan\u003eFTA-T-02\u003c\/span\u003e requires a used rail length of \u003cspan\u003e14.6 cm\u003c\/span\u003e. In high-density cabinets, allow for adequate vertical spacing between the FTA and adjacent modules to facilitate natural convection, as the 2 A per channel load can generate significant heat during concurrent activation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGrounding for EMC Compliance:\u003c\/span\u003e To maintain the \u003cspan\u003eCE and UL\u003c\/span\u003e certification integrity, ensure the DIN rail is bonded to a low-impedance earth ground. This provides a clear path for electrical transients and protects the fail-safe logic from electromagnetic interference (EMI) originating from nearby power switching equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Resilience \u0026amp; Technical Superiority\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell FTA-T-02\u003c\/span\u003e stands as a benchmark for reliability in the Field Termination Assembly sector. Its robust physical construction (\u003cspan\u003e14.5 cm x 7 cm\u003c\/span\u003e) is optimized for the rigors of industrial control rooms where vibration and thermal fluctuations are constant variables. By utilizing high-quality screw terminals and gold-plated connector pins, the \u003cspan\u003eFTA-T-02\u003c\/span\u003e ensures long-term contact stability. As an \u003cspan\u003eOriginal and New\u003c\/span\u003e component, it offers full compatibility with legacy Safety Manager and FSC platforms, providing a high-availability solution for modernizing safety instrumented systems (SIS) without requiring extensive field-wiring re-engineering.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667751825771,"sku":"FTA-T-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-02-fail-safe-digital-output-module-afgq1sfwuk5_07e51c7d-5b35-4f5b-83e6-76cd00ca3f1b.jpg?v=1765501568"},{"product_id":"honeywell-900b16-0001-controledge-hc900-16-slot-i-o-chassis","title":"Honeywell 900B16-0001 ControlEdge HC900 16-Slot I\/O Chassis","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001 (900B16-0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity 16-slot I\/O rack designed for the Honeywell ControlEdge HC900 Process \u0026amp; Safety Controller system. This chassis serves as the physical and communication backbone for various HC900 I\/O modules, including analog inputs\/outputs and digital inputs\/outputs. Engineered for modularity and scalability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both standard process control and SIL 2 safety-related applications, providing a ruggedized mounting platform with integrated power distribution and backplane communications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlEdge HC900 \/ Series 900\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Slots (for I\/O modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReserved Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated slots for Power Supply and Scanner\/CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistributed 5V and 24V from Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Mount (Internal Cabinet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 2 Certified (when used with appropriate modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade aluminum\/steel hybrid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed internal bus for I\/O scanning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eStructural Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to maximize I\/O density within a single rack footprint. It facilitates the \"hot-swap\" capability of the HC900 system, allowing modules to be replaced while the rest of the rack remains powered and operational. The chassis includes integrated grounding points and terminal block connectors for the power supply, ensuring clean power delivery to sensitive analog instrumentation. It is a critical component for large-scale boiler control, thermal processing, and water treatment applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this chassis include the Power Supply or CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the empty 16-slot rack frame. The Power Supply (e.g., 900P01) and the CPU or Scanner module must be purchased and installed separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix safety and non-safety modules in this rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the HC900 architecture allows for the coexistence of non-safety and safety-critical I\/O within the same chassis, provided the system configuration adheres to the Honeywell Safety Manual guidelines.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667990147435,"sku":"900B16-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-900b16-0001-plc-module-s1z4in1e0wu_03d48335-7db6-4543-a6e4-e6c67c76b1f5.jpg?v=1765504887"},{"product_id":"honeywell-51454416-300-experion-pks-c300-controller-module","title":"Honeywell 51454416-300 Experion PKS C300 Controller Module","description":"\u003ch3 data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eOverview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe \u003cb data-path-to-node=\"2\" data-index-in-node=\"4\"\u003e51454416-300 (51454416-300)\u003c\/b\u003e is a core processing unit for the Honeywell Experion® PKS (Process Knowledge System). As a C300 Controller, it executes control strategies, manages I\/O communications, and supports peer-to-peer data exchange across the Honeywell Fault Tolerant Ethernet (FTE) network. This specific hardware revision is engineered for high-performance process control, offering the computational power required for complex continuous control, batch processing, and advanced regulatory control (ARC) in demanding industrial environments.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"0\"\u003eDetailed Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"4\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,1,0,0\"\u003e\u003cb data-path-to-node=\"4,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,1,1,0\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,2,0,0\"\u003e\u003cb data-path-to-node=\"4,2,0,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,2,1,0\"\u003e\u003cb data-path-to-node=\"4,2,1,0\" data-index-in-node=\"0\"\u003e51454416-300\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,3,0,0\"\u003e\u003cb data-path-to-node=\"4,3,0,0\" data-index-in-node=\"0\"\u003eProduct Family\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,3,1,0\"\u003eExperion C300 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,4,0,0\"\u003e\u003cb data-path-to-node=\"4,4,0,0\" data-index-in-node=\"0\"\u003eProcessor Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,4,1,0\"\u003eHigh-performance embedded RISC processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,5,0,0\"\u003e\u003cb data-path-to-node=\"4,5,0,0\" data-index-in-node=\"0\"\u003eMemory Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,5,1,0\"\u003e128 MB (Standard for -300 Series)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,6,0,0\"\u003e\u003cb data-path-to-node=\"4,6,0,0\" data-index-in-node=\"0\"\u003eCommunication Protocol\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,6,1,0\"\u003eFault Tolerant Ethernet (FTE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,7,0,0\"\u003e\u003cb data-path-to-node=\"4,7,0,0\" data-index-in-node=\"0\"\u003eRedundancy Support\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,7,1,0\"\u003eFully redundant (when paired with a second C300 and redundancy cable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,8,0,0\"\u003e\u003cb data-path-to-node=\"4,8,0,0\" data-index-in-node=\"0\"\u003eControl Execution Environment\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,8,1,0\"\u003eCEE (Control Execution Environment)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,9,0,0\"\u003e\u003cb data-path-to-node=\"4,9,0,0\" data-index-in-node=\"0\"\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,9,1,0\"\u003e0 °C to 60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,10,0,0\"\u003e\u003cb data-path-to-node=\"4,10,0,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,10,1,0\"\u003eSeries C IOTA (Input\/Output Termination Assembly)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,11,0,0\"\u003e\u003cb data-path-to-node=\"4,11,0,0\" data-index-in-node=\"0\"\u003eRelative Humidity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,11,1,0\"\u003e5% to 95% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003ePerformance Capabilities\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe \u003cb data-path-to-node=\"6\" data-index-in-node=\"4\"\u003e51454416-300\u003c\/b\u003e provides a deterministic environment for executing control logic. It utilizes a vertical form factor that integrates directly onto a Series C IOTA, optimizing thermal dissipation and reducing cabinet footprint. Key features include sub-second control loops and the ability to handle thousands of I\/O points per controller pair. The module's design allows for online firmware upgrades and hardware replacement without interrupting the process, provided a redundant pair is established.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eFAQs\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eHow does the -300 model differ from the older -100 or -200 versions?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eThe \u003cb data-path-to-node=\"8\" data-index-in-node=\"73\"\u003e51454416-300\u003c\/b\u003e features enhanced processing speed and expanded memory capacity compared to earlier revisions, allowing it to support larger control strategies and more intensive communication loads within the Experion network.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eDoes this module require a specific IOTA?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eYes, the C300 controller must be mounted on a dedicated C300 IOTA (such as the 51403519-160 for simplex or 51403519-260 for redundant configurations).\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668010922347,"sku":"51454416-300","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-51454416-300-plc-module-ht144yylphy_f5bff814-8ced-4770-bb10-22d46e0ddeaa.jpg?v=1765505103"},{"product_id":"honeywell-cc-pail51-experion-series-c-low-level-analog-input-module","title":"Honeywell CC-PAIL51 Experion Series-C Low Level Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-71\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-71\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-71\"\u003eCC-PAIL51 (CCPAIL51)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-71\"\u003e\u003cspan\u003e \u003c\/span\u003estands as a high-performance temperature sensing solution within the Honeywell Experion Series-C Mark II I\/O family\u003c\/span\u003e\u003cspan class=\"citation-71 citation-end-71\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-70\"\u003e\u003c\/span\u003eSpecifically engineered for mission-critical thermal monitoring in industries such as hydrocarbon processing and power generation, this Low Level Analog Input (LLAI) module provides high-density support for 16 RTD and Thermocouple (TC) circuits\u003cspan class=\"citation-70 citation-end-70\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-69\"\u003e\u003c\/span\u003eThe module’s core value lies in its high-integrity data qualification; it features a fixed 1-second PV scanning rate coupled with advanced Open Thermocouple Detection (OTD) protection\u003cspan class=\"citation-69 citation-end-69\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-68\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-68\"\u003eBy automatically setting Process Variables to \"Not a Number\" (NAN) upon sensor failure, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-68\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-68\"\u003e\u003cspan\u003e \u003c\/span\u003eprevents erratic control loop responses, effectively reducing plant risk and minimizing expensive unscheduled maintenance caused by instrument degradation\u003c\/span\u003e\u003cspan class=\"citation-68 citation-end-68\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-67\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-67\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-67\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-67\"\u003e\u003cspan\u003e \u003c\/span\u003ehardware is optimized for signal stability and thermal management within high-density cabinet environments\u003c\/span\u003e\u003cspan class=\"citation-67 citation-end-67\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-66\"\u003eComprehensive Sensor Library:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-66\"\u003e\u003cspan\u003e \u003c\/span\u003eNative linearization for a broad spectrum of sensors, including Platinum (100 ohm), Nickel (120 ohm), and Copper (10\/50 ohm) RTDs, as well as ANSI Type J, K, E, T, B, S, and R thermocouples\u003c\/span\u003e\u003cspan class=\"citation-66 citation-end-66\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-65\"\u003eTotal Galvanic Isolation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-65\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides robust 16-channel isolation, including channel-to-channel, channel-to-DCS backplane, and channel-to-power common, shielding sensitive measurements from ground loop interference\u003c\/span\u003e\u003cspan class=\"citation-65 citation-end-65\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1-second update cycle includes a mandatory OTD check before PV propagation.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-64\"\u003e\u003c\/span\u003eIf sensor resistance exceeds 1500 ohms, the system triggers a guaranteed trip to protect control integrity\u003cspan class=\"citation-64 citation-end-64\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-63\"\u003eSeries-C Mark II Innovation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-63\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes the \"tilted\" module design for superior heat dissipation and features a vertical mounting profile to streamline high-density field wiring entry\u003c\/span\u003e\u003cspan class=\"citation-63 citation-end-63\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eCC-PAIL51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eHoneywell Experion Series-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eLow Level Analog (Temperature) Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e16 (Fully Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e1 second (Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eIOTA Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e\n\u003ca href=\"https:\/\/www.plcprotech.com\/products\/dc-tail51-honeywell-series-c-analog-output-24v-iota-module\"\u003eDC-TAIL51\u003c\/a\u003e (Non-Redundant 9-inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eNominal Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e-20 to +100 mV (TC only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eGain Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e0.050% Full Scale Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eTemperature Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e+\/- 20 ppm per deg C Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eCMRR (50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e120 dB Minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eRTD Excitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e1 milliamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e0 to 60 deg C (Standard Series-C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the CC-PAIL51 prevent \"false\" control actions during a sensor break?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-62\"\u003e\u003c\/span\u003eThe module utilizes a \"sample and hold\" OTD cycle\u003cspan class=\"citation-62 citation-end-62\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-61\"\u003e\u003c\/span\u003eIf an open sensor is detected, the Process Variable is set to NAN (Not a Number) and a soft failure is reported\u003cspan class=\"citation-61 citation-end-61\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-60\"\u003e\u003c\/span\u003eThis ensures no invalid data is propagated to the controller, preventing inappropriate PID responses\u003cspan class=\"citation-60 citation-end-60\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the specific IOTA options for this module?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-59\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-59\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-59\"\u003e\u003cspan\u003e \u003c\/span\u003etypically resides on the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-59\"\u003eDC-TAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-59\"\u003e\u003cspan\u003e \u003c\/span\u003eIOTA, which is a 9-inch (228 mm) assembly for non-redundant applications\u003c\/span\u003e\u003cspan class=\"citation-59 citation-end-59\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support millivolt-only inputs without linearization?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-58\"\u003e\u003c\/span\u003eYes, the module supports standard millivolt types ranging from -20 to +100 millivolts, allowing it to interface with specialized non-standard sensing devices\u003cspan class=\"citation-58 citation-end-58\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-57\"\u003eCold Junction Compensation (CJC):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-57\"\u003e\u003cspan\u003e \u003c\/span\u003eAll thermocouple inputs are automatically compensated using a CJC device located on the IOTA\u003c\/span\u003e\u003cspan class=\"citation-57 citation-end-57\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. To ensure accuracy, avoid installing the IOTA near high-heat components that could create localized thermal gradients across the termination assembly. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-56\"\u003eRTD Wiring Integrity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-56\"\u003e\u003cspan\u003e \u003c\/span\u003eFor RTD sensors, lead resistance must be strictly managed (maximum 15 ohms)\u003c\/span\u003e\u003cspan class=\"citation-56 citation-end-56\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-55\"\u003e\u003c\/span\u003eUse high-quality shielded 3-wire or 4-wire cabling to maintain the 120 dB Common Mode Rejection Ratio (CMRR) and prevent noise from distorting low-level temperature signals\u003cspan class=\"citation-55 citation-end-55\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-54\"\u003eSurge Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-54\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module features integrated surge protection per EN 61000-4-5 (1 kV line-to-line, 2 kV line-to-ground)\u003c\/span\u003e\u003cspan class=\"citation-54 citation-end-54\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. For outdoor sensor runs or environments with high lightning risk, external primary surge arrestors are still recommended to protect the IOTA electronics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668023210347,"sku":"CC-PAIL51","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-pail51-low-level-analog-output-ffkuwq3reb5_d4e37d60-6deb-45a2-8082-bc85412bb644.jpg?v=1765505238"},{"product_id":"honeywell-experion-pks-8c-pcnt05-51454363-275-c300-controller","title":"Honeywell Experion PKS 8C-PCNT05 (51454363-275) C300 Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-558\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PCNT05 (51454363-275)\u003c\/strong\u003e\u003cspan class=\"citation-558\"\u003e\u003cspan\u003e \u003c\/span\u003eis the latest generation\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eC300 Control Processor\u003c\/strong\u003e\u003cspan class=\"citation-558\"\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan class=\"citation-558 citation-end-558\"\u003e\u003cspan\u003e \u003c\/span\u003eplatform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-557 citation-end-557\"\u003eAs the most advanced iteration of the C300 family, the \"05\" version is designed to handle the most demanding process control requirements of modern industrial facilities.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt features upgraded internal hardware that provides a significant increase in processing power and memory efficiency compared to the older 02 and 03 revisions. The part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51454363-275\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifically identifies this as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 Conformal Coated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit, ensuring maximum reliability in environments prone to corrosive gases. This controller is specifically optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS software releases R520 and later\u003c\/strong\u003e, making it the primary choice for new greenfield projects and modern system expansions.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PCNT05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is built to support the future of digital transformation in process automation.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-556\"\u003e\u003c\/span\u003e\u003cstrong\u003eModern CPU Architecture\u003c\/strong\u003e\u003cspan class=\"citation-556 citation-end-556\"\u003e: Utilizes a high-speed multi-core processor designed for deterministic execution of complex Control Execution Environment (CEE) strategies.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Memory Capacity\u003c\/strong\u003e: Offers the highest memory density in the Series 8 C300 line, allowing for more complex function blocks and larger sequential control charts within a single controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFTE Integration\u003c\/strong\u003e: Features dual-redundant Fault Tolerant Ethernet (FTE) connectivity, providing high-availability communication with the server and peer-to-peer data exchange with other controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-555\"\u003e\u003c\/span\u003e\u003cstrong\u003eCorrosion Resistance\u003c\/strong\u003e\u003cspan class=\"citation-555 citation-end-555\"\u003e: Factory-applied G3 coating protects the high-density electronic components from H2S, Cl2, and high humidity, meeting ISA S71.04 Class G3 standards.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBumpless Redundancy\u003c\/strong\u003e: When installed on a redundant IOTA, two 8C-PCNT05 units provide a synchronized primary\/secondary pair with instantaneous, state-aware failover.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PCNT05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51454363-275\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC300 Control Processor (Version 5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion R520 and Higher\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 1024 I\/O points (System dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExecution Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum 50 ms loop time\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.05 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix an 8C-PCNT03 and an 8C-PCNT05 in a redundant pair?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Redundant pairs must be of the same hardware version to ensure identical execution timing and memory synchronization. You cannot pair an \"03\" with an \"05\" for redundancy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this processor compatible with my Experion R410 system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenerally, no. The 8C-PCNT05 is designed for modern software stacks (typically R520+). If you are running an older software version, you should use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PCNT03\u003c\/strong\u003e, which maintains broader legacy compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this version include the internal battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLike other modern C300 processors, the 8C-PCNT05 utilizes non-volatile RAM and Flash memory for control strategy storage, eliminating the reliance on traditional batteries for program retention during power cycles.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways connect the \"Yellow\" and \"Green\" FTE cables to their designated ports on the IOTA. Ensure the FTE cables are Category 6 or higher to support the high-speed data throughput requirements of the 8C-PCNT05.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOTA Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller must be mounted on a Series 8 C300 IOTA (e.g., 8C-TCNTA1). Proper electrical bonding between the IOTA and the cabinet’s instrument earth is critical to prevent electrostatic discharge (ESD) from damaging the processor’s high-speed logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Link:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor redundant configurations, ensure the redundancy cable connecting the two IOTA slots is undamaged and securely locked. A faulty redundancy cable is a common cause of \"Synchronization Failure\" alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough this unit is G3 coated, always ensure that cabinet doors are kept closed and cable entries are sealed with proper glands to minimize the exposure of non-coated terminal connections to corrosive air.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668024684907,"sku":"8C-PCNT05 51454363-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-pcnt05-51454363-275-controller-module-kgiqxif0a1y_2584baf8-a696-449a-98c5-56fc50affb76.jpg?v=1765505257"},{"product_id":"honeywell-experion-pks-8c-pcnt03-c300-control-processor","title":"Honeywell Experion PKS 8C-PCNT03 C300 Control Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-539\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PCNT03 (8CPCNT03)\u003c\/strong\u003e\u003cspan class=\"citation-539\"\u003e\u003cspan\u003e \u003c\/span\u003eis the modern standard Control Processor for the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eExperion PKS (Process Knowledge System) Series 8\u003c\/strong\u003e\u003cspan class=\"citation-539 citation-end-539\"\u003e\u003cspan\u003e \u003c\/span\u003eplatform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt serves as the successor to the 8C-PCNT02, offering enhanced processing power and expanded memory while maintaining full backward compatibility with all previous Experion LX and PlantCruise releases.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-538\"\u003eAs the \"brain\" of the Series 8 system, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e8C-PCNT03\u003c\/strong\u003e\u003cspan class=\"citation-538 citation-end-538\"\u003e\u003cspan\u003e \u003c\/span\u003eexecutes the deterministic Control Execution Environment (CEE), managing complex regulatory control, batch sequences, and fast-logic strategies.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-537\"\u003eThis version is factory-shipped with a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eG3 conformal coating\u003c\/strong\u003e\u003cspan class=\"citation-537 citation-end-537\"\u003e, providing the highest level of protection against corrosive atmospheric contaminants (such as Hydrogen Sulfide and Chlorine), making it the primary choice for global chemical, oil, and gas operations.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-536\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e8C-PCNT03\u003c\/strong\u003e\u003cspan class=\"citation-536 citation-end-536\"\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is designed for extreme reliability and high-speed data processing.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-535\"\u003e\u003c\/span\u003e\u003cstrong\u003eDual Processor Architecture\u003c\/strong\u003e\u003cspan class=\"citation-535 citation-end-535\"\u003e: Utilizes a high-performance multi-processor design (typically Dual ARM Cortex-A9) to ensure fast execution times and deterministic scheduling.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-534\"\u003e\u003c\/span\u003e\u003cstrong\u003eExpanded Memory\u003c\/strong\u003e\u003cspan class=\"citation-534 citation-end-534\"\u003e: Equipped with 512MB RAM and 1GB Flash memory, providing ample space for large-scale control strategies and extensive diagnostic logging.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-533\"\u003e\u003c\/span\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e\u003cspan class=\"citation-533 citation-end-533\"\u003e: Specifically treated to meet ISA S71.04 Class G3 standards for protection against corrosive environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-532\"\u003e\u003c\/span\u003e\u003cstrong\u003eRedundancy Ready\u003c\/strong\u003e\u003cspan class=\"citation-532 citation-end-532\"\u003e: Supports 1-to-1 hardware redundancy.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhen paired with a second 8C-PCNT03 on a redundant IOTA, it provides \"bumpless\" failover in the event of a primary processor fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-531\"\u003e\u003c\/span\u003e\u003cstrong\u003eIntegrated Communication\u003c\/strong\u003e\u003cspan class=\"citation-531 citation-end-531\"\u003e: Features dual FTE (Fault Tolerant Ethernet) ports for high-security network integration and dual I\/O Link ports for controlling up to 1024 I\/O points.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PCNT03\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC300 Control Processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512MB RAM \/ 1GB Flash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExecution Period\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 ms to 2000 ms (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to 70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 IOTA (8C-TCNTA1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, FM Class I Div 2, ATEX Zone 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg (Net) \/ 3.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 8C-PCNT03 compatible with my existing 8C-PCNT02 configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 8C-PCNT03 is the direct replacement for the 8C-PCNT02. It can be installed on the same IOTA and is compatible with all current and previous Experion software releases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 8C-PCNT03 and 8C-PCNT05?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PCNT03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both new and legacy Experion releases, making it ideal for maintenance and upgrades of existing systems. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PCNT05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the newest version (V5) and only supports Experion R520 and later; notably, the 03 and 05 versions are not interoperable in a redundant pair.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller support peer-to-peer communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The C300 CEE supports high-speed peer-to-peer communication with other C300 controllers over the FTE network, as well as communication with specialty modules like Foundation Fieldbus and Profibus.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpgrade Note:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen replacing an older 8C-PCNT02 with an 8C-PCNT03 in a redundant pair, it is recommended to eventually replace both units to the same hardware revision to ensure identical execution timing and memory handling, although they can operate together during the migration period.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse only Honeywell-certified shielded Ethernet cables for FTE connections. Ensure that the \"Yellow\" and \"Green\" cables are connected to their respective ports on the IOTA to maintain the integrity of the Fault Tolerant Ethernet logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8C-PCNT03 relies on the Series 8 vertical design for natural convection. Ensure the cabinet has sufficient ventilation and that the 150 mm clearance rule is observed above and below the IOTA row to prevent the processor from overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668027240811,"sku":"8C-PCNT03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-pcnt03-series-8-c300-controller-gcrri2ue45p_ed94f917-8724-426a-8306-1db1b7d64423.jpg?v=1765505290"},{"product_id":"honeywell-experion-pks-8c-tdoda1-51307149-175-digital-output-iota","title":"Honeywell Experion PKS 8C-TDODA1 (51307149-175) Digital Output IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TDODA1 (51307149-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 32-channel Digital Output Termination Assembly (IOTA) designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform. This \"Single\" IOTA serves as the mounting base and field wiring interface for a single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output module. It is engineered to drive 24 VDC discrete field devices such as solenoid valves, relays, and indicator lamps. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures the signature Series 8 vertical design, which significantly reduces the cabinet footprint while enhancing thermal management through natural convection. This specific version (51307149-175) is factory-treated with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 conformal coating\u003c\/strong\u003e, providing a critical layer of protection against moisture and corrosive atmospheric elements commonly found in industrial processing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODA1 (51307149-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a ruggedized electrical interface for discrete control.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32-Channel Single-Ended Interface\u003c\/strong\u003e: Accommodates 32 digital output channels, allowing for high-density wiring and simplified common-return routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"175\" suffix indicates compliance with ISA S71.04 Class G3, protecting the PCB and components from corrosive gases like Hydrogen Sulfide (H2S) and Chlorine (Cl2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Series 8 Form Factor\u003c\/strong\u003e: Fits onto a standard Series 8 carrier, facilitating an efficient \"chimney-effect\" airflow that keeps the electronic module cool.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Circuit Protection\u003c\/strong\u003e: Designed to work with the I\/O module’s diagnostic capabilities, including short-circuit protection and load monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Friendly Design\u003c\/strong\u003e: Allows for the electronic I\/O module to be replaced (\"hot-swapped\") without disconnecting the field wiring terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307149-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (32-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.60 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA in a redundant configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-TDODA1 is a \"Single\" IOTA, meaning it has only one slot for an I\/O module. For redundant DO applications where two modules back up each other, you must use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eredundant IOTA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum current per channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module can drive typical 24 VDC solenoids, the total current capacity is limited. For high-current loads or high-frequency switching, it is highly recommended to use interposing relays to prevent thermal stress on the IOTA and module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the field power provided to the outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField excitation power (24 VDC) is usually supplied through the Series 8 carrier busbar. The IOTA then distributes this power to the individual channels based on the commands from the C300 controller.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Precautions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse ferrules on all field wiring to ensure reliable contact and prevent stray wire strands from shorting adjacent terminals in the high-density terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the IOTA is firmly snapped into the carrier and that the carrier itself is properly bonded to the instrument ground bar. Inadequate grounding can lead to intermittent diagnostic errors and susceptibility to electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor the \"Blown Fuse\" diagnostics in the Experion software. If a fuse-protected circuit is used, identify and rectify the field-side short circuit before replacing the module or resetting the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Spacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the manufacturer-specified 150 mm clearance above and below the IOTA row to ensure adequate cooling. Overheating is a primary cause of shortened electronic lifespan in high-density DC cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668027765099,"sku":"8C-TDODA1 51307149-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdoda1-51307149-175-digital-output-bussed-irxllnpltok_da87522a-b045-4c95-88b5-ba132f5cec30.jpg?v=1765505296"},{"product_id":"honeywell-experion-pks-8c-paona1-51454469-175-analog-output-module","title":"Honeywell Experion PKS 8C-PAONA1 (51454469-175) Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAONA1 (51454469-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 16-channel Analog Output (AO) module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O architecture. As a core component of the C300 control system, this module converts digital control algorithms into accurate 4-20 mA analog signals to drive final control elements such as valve positioners, variable speed drives, and dampers. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically engineered for high-density deployments, featuring the Series 8 slim vertical form factor that enhances natural convection cooling. This \"175\" variant comes standard with a factory-applied G3 conformal coating, providing essential protection against corrosive atmospheric contaminants. By ensuring stable signal delivery in harsh industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplays a vital role in maintaining process stability and reducing the total cost of ownership through enhanced hardware durability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1 (51454469-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its ruggedized electronics and seamless integration with the Series 8 I\/O Link.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity\u003c\/strong\u003e: Supports up to 16 independent analog loops per module, maximizing I\/O density within the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-HART Signal Path\u003c\/strong\u003e: Dedicated to standard 4-20 mA analog modulation, offering a streamlined and cost-effective solution for control loops that do not require digital HART diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The 51454469-175 hardware revision is specifically treated to resist corrosion from H2S, Cl2, and ammonia, meeting ISA S71.04 Class G3 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Provides comprehensive electrical isolation between field wiring and the internal system bus, protecting the C300 controller from field transients and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Ready\u003c\/strong\u003e: Fully compatible with redundant Series 8 IOTAs, allowing for seamless bumpless transfer in high-availability control applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAONA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51454469-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output (Non-HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.8 Watts Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.20 x 9.80 x 4.20 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an 8C-PAONA1 with an 8C-PAOHA1 (HART version)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 8C-PAOHA1 is generally backward compatible and can reside on the same IOTA. However, you must update the module configuration in the Experion Control Builder to enable the HART features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"Non-HART\" designation mean for my field devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt means this module only transmits the 4-20 mA analog signal. If you have \"Smart\" valve positioners, they will still move correctly based on the current, but the DCS will not be able to read digital diagnostic data or valve signatures from them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the G3 coating on this part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number suffix \"175\" is the primary indicator of the G3 conformal coating. Physically, the board will have a slight uniform sheen compared to non-coated \"100\" series boards when viewed under reflected light.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Impedance Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8C-PAONA1 is designed to drive loads up to a maximum of 600 Ohms. Before commissioning, calculate the total loop resistance including the field wire run and the positioner impedance. High-resistance loops can cause the output to saturate or trigger \"Output Open\" alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). In a redundant configuration, ensure the \"OK\" LED on the partner module is solid green before removing the module being serviced to prevent a process upset.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Noise Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain signal integrity, use individual shielded twisted-pair cables for each AO channel. The shields must be terminated at the IOTA's ground bar to prevent electromagnetic interference from inducing \"jitter\" in the valve control signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031205739,"sku":"8C-PAONA1 51454469-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paona1-51454469-175-analog-output-module-pr3lnm2gi33_9db50288-9e32-48b9-bb61-3adc7964f986.jpg?v=1765505321"},{"product_id":"honeywell-experion-pks-8c-tdila1-51307141-175-digital-input-iota","title":"Honeywell Experion PKS 8C-TDILA1 (51307141-175) Digital Input IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TDILA1 (51307141-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Digital Input Termination Assembly (IOTA) belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. This module acts as the physical and electrical foundation for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PDILA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input module, providing 32 channels of discrete signal acquisition. It is designed to interface with field contacts such as push-buttons, limit switches, and motor starter auxiliary contacts. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered with the signature Series 8 vertical orientation to optimize cabinet space and enhance thermal management through natural convection. This specific variant, identified by part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51307141-175\u003c\/strong\u003e, features a factory-applied G3 conformal coating, making it resilient against corrosive gases and high-humidity environments typical in oil refineries and chemical processing plants.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILA1 (51307141-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for high-speed signal processing and simplified field maintenance.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32-Channel Single-Ended Interface\u003c\/strong\u003e: Provides terminal connections for up to 32 discrete inputs, sharing a common return to maximize wiring density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"175\" suffix ensures the board is treated to withstand harsh environmental conditions, protecting against corrosion from Hydrogen Sulfide (H2S) and Chlorine (Cl2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Form Factor\u003c\/strong\u003e: Mounts onto a Series 8 carrier, allowing for a \"slim\" I\/O profile that significantly reduces the overall footprint of the DCS cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Management\u003c\/strong\u003e: Distributes 24 VDC field excitation power to the input contacts while maintaining electrical isolation for the C300 controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance\u003c\/strong\u003e: The IOTA design allows for the replacement of the electronic I\/O module without disturbing the field wiring connected to the terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDILA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307141-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input (32-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PDILA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Compression Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.65 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 11.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 8C-TDILA1 support redundant input module configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-TDILA1 is a \"Single\" IOTA, meaning it supports only one 8C-PDILA1 module. For redundant applications where two modules monitor the same 32 field points, you must use the redundant version, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILB1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field excitation voltage does this IOTA provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis IOTA is designed for 24 VDC discrete inputs. The 24 VDC power is typically sourced from the system power supply through the Series 8 carrier bus and distributed to the field contacts via the IOTA terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA in a non-corrosive environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the G3 coating (51307141-175) is designed for harsh environments, it is fully compatible with standard control room environments. It provides an extra layer of protection against unexpected humidity or airborne contaminants.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Organization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven the 32-channel density, use fine-stranded wire with ferrules for all connections to the compression terminals. Clear labeling and organized wire ducting are essential to prevent cross-talk and facilitate future troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the IOTA is properly snapped into the Series 8 carrier and that the carrier is bonded to the instrument earth bar. Proper grounding is critical for the internal surge protection circuitry to function correctly during field-side transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the recommended 150 mm clearance above and below the IOTA row. The vertical design relies on the \"chimney effect\" for cooling; obstructing airflow can lead to localized hotspots and premature failure of the inserted I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031304043,"sku":"8C-TDILA1 51307141-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdila1-51307141-175-input-module-hhpp2chb3tf_64736da3-58c9-4b6e-97d0-b96456e712d1.jpg?v=1765505322"},{"product_id":"honeywell-tc-ccr013-controlnet-redundant-communications-module","title":"Honeywell TC-CCR013 ControlNet Redundant Communications Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-CCR013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance ControlNet interface within the ControlLogix architecture, engineered specifically for mission-critical applications requiring physical media redundancy. Unlike standard single-channel modules, this dual-media interface ensures continuous data flow across redundant trunk cables (Trunk A and Trunk B). It facilitates high-speed, deterministic communication between controllers, I\/O chassis, and human-machine interfaces (HMI) in complex industrial networks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Engineering Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControlNet (RG-6 Coaxial 기반)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Transfer Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFixed at 5 Mbit\/sec\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual Media (Trunk A \u0026amp; Trunk B support)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBus topology utilizing BNC connectors and Taps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Node Distance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCombined Coax\/Fiber length up to 10 km\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSegment Length (Coax):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$1000\\text{ m} - (16.3\\text{ m} \\times [\\text{Taps} - 2])$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRepeater Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 5 Repeaters per communication path\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLink Differential:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e800 m maximum allowed length difference between redundant trunk cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRG-6 Quad Shield (Standard PVC, Armored, Plenum FEP, or Flood Burial variants)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Topology Constraints\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimit \/ Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Segments\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 segments per network\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTopology Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrunk line\/Drop line\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMedia Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual BNC ports for seamless switchover\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-level electromagnetic interference (EMI) resistance via Quad Shielding\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Availability Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in chemical processing, power generation, and wastewater treatment where network failure is not an option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDeployment in extreme temperature zones or corrosive areas using Plenum-rated FEP cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Reach Networks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing repeaters and fiber optic bridges to span distances up to 10,000 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if Trunk A is disconnected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-CCR013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautomatically switches to Trunk B without interrupting the process data. The module continuously monitors the health of both paths to ensure deterministic performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used with fiber optics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, while the module natively uses BNC coax, it can interface with fiber optic segments through the use of ControlNet fiber repeaters to extend the total network distance to 10 km.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031697259,"sku":"TC-CCR013","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-tc-ccr013-redundant-net-interface-module-5jsbhffojet_31906496-0c73-410a-8356-4f9330ce414a.jpg?v=1765505328"},{"product_id":"honeywell-fc-cpchas-0002-safety-manager-control-processor-chassis","title":"Honeywell FC-CPCHAS-0002 Safety Manager Control Processor Chassis","description":"\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-CPCHAS-0002 (FC-CPCHAS-0002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity chassis engineered specifically for the Honeywell Safety Manager™ (SMS) and Experion® PKS environments. This core infrastructure component is designed to house and provide a redundant backplane for Control Processor (CP) modules, such as the CP3402. By facilitating dual-processor configurations, it enables the Quadruple Modular Redundancy (QMR) technology essential for SIL 3 safety-critical applications, including emergency shutdown (ESD) and fire and gas (F\u0026amp;G) detection systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFC-CPCHAS-0002\u003c\/strong\u003e (also known as \u003cstrong\u003eFS-CPCHAS-0002\u003c\/strong\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Safety Manager, Experion PKS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCertified up to SIL 3 (IEC 61508)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Control Processor (CP) module capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5V-1: 0.05 A \/ 5V-2: 0.05 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e177 mm x 482.6 mm x 280 mm (7 in x 19 in x 11 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRack Units\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 HE (Standard 19-inch Rack Mount)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.8 kg (12.8 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRuggedized industrial-grade steel with backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-CPCHAS-0002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the physical and electrical backbone for the safety controller. It features a high-speed communication backplane that manages the data exchange between redundant CPs and I\/O expansion modules. The chassis is built to withstand harsh industrial environments, ensuring that critical safety logic remains uninterrupted even during a single processor failure or maintenance event.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this chassis compatible with non-redundant setups?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, while designed for high availability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-CPCHAS-0002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan support a simplex (non-redundant) configuration by utilizing a single control processor slot, though it is primarily selected for its redundant capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit include the power supply modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe chassis features an integrated backplane for power distribution; however, specific power supply units (PSUs) and CP modules must be ordered separately to complete the system.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668033696107,"sku":"FC-CPCHAS-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fc-cpchas-0002-plc-rack-chassis-w1kq1smgros_e9a9ddfc-8c1d-4096-90e8-5a98ac98395a.jpg?v=1765505350"},{"product_id":"honeywell-experion-pks-8c-paona2-analog-output-module-non-hart","title":"Honeywell Experion PKS 8C-PAONA2 Analog Output Module (Non-HART)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAONA2 (8CPAONA2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Analog Output (AO) module belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. Engineered for precision and mission-critical reliability, this 16-channel module converts digital control commands from the C300 controller into standard 4-20 mA analog signals. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily used to drive final control elements such as pneumatic valve positioners, variable speed drives (VSD), and dampers. As a \"Series 8\" component, it features a vertical, slimline design that optimizes cabinet density and promotes natural thermal convection. This specific variant is the \"Non-HART\" version, providing a cost-effective solution for control loops where digital field device diagnostics are not required, while maintaining the rugged G3-level environmental protection standard in Honeywell's premium I\/O line.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to integrate seamlessly into the Experion PKS architecture, focusing on signal stability and hardware longevity.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Density\u003c\/strong\u003e: Provides 16 independent analog output channels, allowing for high-density I\/O configurations in a small physical footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries 8 Architecture\u003c\/strong\u003e: Designed to be \"plug-and-play\" with Series 8 IOTAs (Input Output Termination Assemblies), supporting both non-redundant and redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The module is factory-treated with a conformal coating to protect internal circuitry against humidity and corrosive atmospheric contaminants (ISA S71.04 Class G3).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Features robust isolation between the I\/O Link (backplane) and the field-side electronics, preventing ground loops and protecting the C300 processor from field electrical faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Loop Response\u003c\/strong\u003e: Optimized for low-latency signal delivery, ensuring that control valve movements are synchronized with the DCS PID logic for stable process modulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 254.719px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e8C-PAONA2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eAnalog Output (Non-HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e12-bit Minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e5.5 Watts Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e15.00 x 10.00 x 4.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 8C-PAONA2 be used to communicate with HART-enabled valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 8C-PAONA2 can drive a HART-enabled valve positioner using a standard 4-20 mA signal, it\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecannot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eread or write digital HART data. For full HART pass-through and diagnostics, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOHA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule must be used instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle a loss of communication with the controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-PAONA2 features a configurable \"Fail-Safe\" state. In the event of an I\/O Link failure or controller shutdown, each channel can be programmed to Hold Last Value (HLV) or go to a pre-defined safe value (e.g., 0 mA or 4 mA).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with older Series A or Series C IOTAs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-PAONA2 is strictly a Series 8 module and must be mounted on a Series 8 IOTA, such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Single) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Redundant).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance Matching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the total loop resistance (including field wiring and the actuator\/positioner impedance) does not exceed the module's maximum drive capability, typically 600 Ohms at 24 VDC. Exceeding this limit will result in \"Output Low\" errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Procedure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). When replacing a module in a redundant pair, ensure the \"Secondary\" LED is stable before removing the \"Primary\" module to ensure a bumpless transfer of control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse twisted-pair shielded cable for all 16 channels. The shield should be grounded at the IOTA's grounding bar. Proper shielding is critical to prevent electromagnetic interference (EMI) from inducing \"jitter\" in the 4-20 mA output signal, which can lead to premature mechanical wear on valve positioners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668035236203,"sku":"8C-PAONA2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paona2-dcs-backplane-nkoilvcvcx2_ef231f8b-558f-431c-9001-1acf9869e5f7.jpg?v=1765505367"},{"product_id":"honeywell-experion-pks-8c-tdodb1-digital-output-redundant-iota","title":"Honeywell Experion PKS 8C-TDODB1 Digital Output Redundant IOTA","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eHoneywell 8C-TDODB1 (8CTDODB1)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability Digital Output Termination Assembly (IOTA) designed for the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis \"Redundant\" IOTA is a critical infrastructure component that allows two\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-PDODA1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output modules to operate in a 1-out-of-2 (1oo2) configuration.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn this setup,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe primary and secondary modules work in tandem; if the primary module fails,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe secondary module takes over control of the field devices instantaneously without a \"bump\" in the process.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis primarily utilized in sectors requiring mission-critical safety and uptime,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as Emergency Shutdown (ESD) systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eturbine trip circuits,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand critical solenoid header controls in chemical and power plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to provide a robust physical and electrical foundation for redundant digital control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundant Module Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures two dedicated slots for Digital Output modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emanaging the synchronization and load-sharing logic between the two units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e32-Channel Density\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 32 individual digital output channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etypically used for driving 24 VDC solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erelays,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor indicator lamps.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eG3 Conformal Coating\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFactory-treated with a protective layer to ensure long-term reliability in environments with high humidity or corrosive gas concentrations (conforming to ISA G3 standards).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVertical I\/O Design\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes the Series 8 vertical mounting format,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich promotes natural airflow for cooling and reduces the overall footprint within the control cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Blown Fuse Detection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides circuit protection and diagnostic feedback to the C300 controller,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing operators to identify field-side wiring faults or short circuits immediately.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDODB1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Redundant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.75 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 12.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan I use only one module on the 8C-TDODB1 IOTA?\u003c\/strong\u003e\u003cspan class=\"\"\u003eYes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhile the 8C-TDODB1 is designed for redundancy,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit can operate with a single module.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe system will report a \"Redundancy Lost\" alarm until the second module is installed and synchronized.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the difference between 8C-TDODA1 and 8C-TDODB1?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe 8C-TDODA1 is a \"Single\" IOTA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting only one module with no hardware redundancy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis the \"Redundant\" version,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efeaturing two module slots for high-availability applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes this IOTA provide power to the field solenoids?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe IOTA distributes 24 VDC power from the cabinet busbar to the outputs.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe total current capacity is limited per channel.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor high-current solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003einterposing relays should be used to protect the IOTA circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundancy Cable Installation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the redundancy link between the two modules is securely seated.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWithout this link,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe modules cannot synchronize their internal states,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eleading to independent operation and potential control conflicts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eField Wiring Termination:\u003c\/strong\u003e\u003cspan\u003e When wiring the 32 channels,\u003c\/span\u003e\u003cspan\u003e use ferrules to prevent stray wire strands from causing short circuits between adjacent terminals.\u003c\/span\u003e\u003cspan\u003e Given the high density of the 8C-TDODB1,\u003c\/span\u003e\u003cspan\u003e cable management and clear labeling are essential for future troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e\u003cspan\u003e The IOTA must be bonded to the instrument earth bar via the carrier's grounding system.\u003c\/span\u003e\u003cspan\u003e Proper grounding is vital for the correct operation of the blown-fuse detection circuitry and to prevent electromagnetic noise from affecting the I\/O Link communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668035662187,"sku":"8C-TDODB1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdodb1-digital-output-module-nto0msgjdle_0be4d2d8-53a4-4ee4-9ea3-94936ec0e1b4.jpg?v=1765505373"},{"product_id":"honeywell-experion-pks-cc-pcnt02-51454551-275-c300-controller-1","title":"Honeywell Experion PKS CC-PCNT02 (51454551-275) C300 Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PCNT02 (51454551-275)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 Control Processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. While it shares the same core control logic as the Series 8 (8C) models, the Series C version is distinguished by its horizontal form factor and its integration with the Series C Input Output Termination Assembly (IOTA). As the \"brain\" of the DCS, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PCNT02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexecutes regulatory control, high-speed logic, and sequential batch procedures. This specific part number,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51454551-275\u003c\/strong\u003e, indicates that the unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 Conformal Coated\u003c\/strong\u003e, providing a robust defense against corrosive atmospheric contaminants in industries like refineries, pulp and paper, and chemical processing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PCNT02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is engineered for extreme availability and high-speed data processing.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries C Horizontal Design\u003c\/strong\u003e: Optimized for horizontal rack mounting, interfacing with the IOTA via a high-density multi-pin connector for stable communication and power distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault Tolerant Ethernet (FTE)\u003c\/strong\u003e: Utilizes dual-redundant FTE ports for secure, high-speed communication between the controller, servers, and other peer nodes on the network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"275\" suffix ensures the internal circuitry meets ISA S71.04 Class G3 standards, protecting against corrosion from H2S, Cl2, and high humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Execution\u003c\/strong\u003e: Supports a configurable Control Execution Environment (CEE), allowing loop execution periods as fast as 50 ms for critical process responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative Redundancy\u003c\/strong\u003e: Supports 1-to-1 hardware redundancy. In a redundant pair, the secondary controller maintains a real-time \"mirror\" of the primary's memory for an instantaneous, bumpless failover.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCC-PCNT02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51454551-275\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC300 Control Processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-density Flash and Non-volatile RAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 50°C (Internal Cabinet Temp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual FTE Ports, Dual I\/O Link Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (via IOTA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.10 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the CC-PCNT01 and the CC-PCNT02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CC-PCNT02 is a modernized hardware revision that provides improved memory management and increased internal processing efficiency. It is the standard replacement for the older CC-PCNT01 in most Experion systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix a CC-PCNT01 and CC-PCNT02 in a redundant pair?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Redundant pairs must consist of identical hardware versions (e.g., two PCNT02 units) to ensure synchronization and identical execution timing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CC-PCNT02 support Series 8 (8C) I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Through the I\/O Link communication, a Series C C300 controller can manage Series 8 I\/O modules, provided the software version and I\/O Link topology are correctly configured in the Experion Control Builder.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOTA Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the CC-PCNT02 is firmly seated into the Series C IOTA and the locking mechanisms are fully engaged. A loose connection at the IOTA interface is a common cause of \"Module Missing\" or \"I\/O Link Failure\" alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Cabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor redundant configurations, the redundancy cable must be connected between the primary and secondary IOTAs. Always verify \"Synchronized\" status in the System Status Display (SSD) before performing any hardware maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse only Honeywell-certified FTE cables. Ensure that the \"Yellow\" and \"Green\" networks are physically isolated to maintain true fault tolerance. Incorrect cross-cabling will result in a \"Secondary Network Failure\" alarm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Retention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the CC-PCNT02 uses non-volatile RAM, it is best practice to perform a \"Checkpoint to Flash\" after any major strategy change to ensure the controller can recover autonomously after a total power loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668037202283,"sku":"CC-PCNT02 51454551-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-pcnt02-51454551-275-controller-module-ox1dtnomdqs_b76e6b5b-b921-45b1-8cd8-46fe20d296c8.jpg?v=1765505395"},{"product_id":"honeywell-experion-pks-8c-taoxa1-51307135-175-analog-output-iota","title":"Honeywell Experion PKS 8C-TAOXA1 (51307135-175) Analog Output IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TAOXA1 (51307135-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Analog Output Termination Assembly (IOTA) belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. As a fundamental component of the C300 control environment, this IOTA provides the physical mounting base and field wiring interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output module. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to support 16 channels of 4-20 mA signals, commonly used to drive control valves, actuators, and speed governors in critical process industries such as oil and gas, power generation, and pharmaceutical manufacturing. Its vertical form factor is a signature of the Series 8 design, engineered to promote natural convection cooling and minimize the footprint within high-density control cabinets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1 (51307135-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for rapid installation and long-term signal integrity in demanding industrial settings.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity\u003c\/strong\u003e: Provides dedicated screw terminal points for 16 analog output loops, supporting both redundant and non-redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Mounting Profile\u003c\/strong\u003e: Specifically designed for the Series 8 Slim chassis, allowing for efficient cable management and superior thermal dissipation compared to traditional horizontal racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The 51307135-175 variant is factory-treated with a protective coating to withstand Class G3 harsh environments, preventing corrosion from H2S, Cl2, and other caustic gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Distribution\u003c\/strong\u003e: Manages the distribution of 24 VDC power from the cabinet bus to the inserted I\/O module and the field-side loop, ensuring consistent drive current across all 16 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Interface\u003c\/strong\u003e: Features robust, high-density compression terminals that facilitate secure connections for field cabling, with integrated support for shield grounding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TAOXA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307135-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output (16-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAOXA1 \/ 8C-PAOYA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Compression Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 10.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 8C-TAOXA1 compatible with HART communication modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the IOTA is a passive termination assembly, it is designed to transparently pass HART digital data when paired with an Analog Output module that supports HART (such as the 8C-PAOHA1).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 51307135-175 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 175 suffix specifically denotes the G3 conformal coating. Standard, non-coated versions carry different suffixes. This version is required for any installation where the control room atmosphere is not strictly regulated for corrosive contaminants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA for redundant AO module configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-TAOXA1 is a non-redundant (Single) IOTA. For redundant applications where two modules back up one another on the same field wiring, you must use the redundant version of the IOTA (8C-TAOXB1).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Discipline\u003c\/strong\u003e: When connecting 4-20 mA loops to the 8C-TAOXA1, ensure that signal cables are kept separate from high-voltage AC lines. Use twisted-pair shielded cables and terminate the shield at the IOTA designated ground point to minimize electromagnetic interference (EMI) that can cause valve hunting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Seating\u003c\/strong\u003e: Before applying power, ensure the 8C-PAOXA1 module is fully seated onto the IOTA and the captive mounting screws are tightened. A loose module can cause intermittent Channel Fault or I\/O Link Failure alarms in the Experion System Status Display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAtmospheric Protection\u003c\/strong\u003e: Since this is the 51307135-175 G3-coated version, ensure that when field wiring is completed, the cabinet entries are sealed. The coating protects the board, but terminal connections remain vulnerable to heavy oxidation if the cabinet is left open in a corrosive environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668040085867,"sku":"8C-TAOXA1 51307135-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-taoxa1-51307135-175-analog-output-module-ee5lfji1kt3_bed50637-0f91-47a7-be5b-ee3622df234d.jpg?v=1765505433"},{"product_id":"nbb20-u1-e0-pepperl-fuchs-inductive-sensor","title":"NBB20-U1-E0 | Pepperl+Fuchs | Inductive Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eNBB20-U1-E0 (NBB20U1E0)\u003c\/strong\u003e is a flush-mounted inductive proximity sensor designed for non-contact metal detection in industrial automation systems. The device provides a \u003cstrong\u003e20 mm sensing distance\u003c\/strong\u003e with stable switching behavior in harsh environments. A \u003cstrong\u003ebidirectional rotatable sensing head\u003c\/strong\u003e allows flexible installation in tight machine layouts. Four LED indicators provide \u003cstrong\u003e360 degree visibility\u003c\/strong\u003e for fast diagnostics during commissioning and maintenance.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eNPN normally open output\u003c\/strong\u003e supports PLC digital input modules commonly used in packaging lines, conveyors, robotics, and material handling systems. The IP68 and IP69K enclosure protects the sensor in washdown areas, mining equipment, and outdoor installations. The robust switching frequency and low hysteresis help reduce false triggering and minimize unplanned downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNBB20-U1-E0\u003c\/strong\u003e model follows Pepperl+Fuchs inductive sensor naming logic:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNBB20\u003c\/strong\u003e indicates a non-flush inductive sensing concept with 20 mm rated distance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eU1\u003c\/strong\u003e defines rectangular housing with universal mounting orientation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE0\u003c\/strong\u003e identifies \u003cstrong\u003e3-wire DC NPN normally open output\u003c\/strong\u003e with screw terminal connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe sensor uses a \u003cstrong\u003e3-wire DC architecture\u003c\/strong\u003e with internal short-circuit protection and reverse polarity protection. The sensing face uses PA material with epoxy-coated metal housing for mechanical durability. The rotatable sensing head allows horizontal or vertical switching alignment without rewiring.\u003c\/p\u003e\n\u003cp\u003eFour integrated LEDs show power status and switching state from multiple directions. This improves troubleshooting speed inside cabinets or machine frames.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNBB20-U1-E0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInductive Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Sensing Distance\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssured Sensing Distance\u003c\/td\u003e\n\u003ctd\u003e0 to 16.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eNPN Normally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003c\/td\u003e\n\u003ctd\u003e3-wire DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003eup to 440 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Current\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003eless than or equal to 2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Load Current\u003c\/td\u003e\n\u003ctd\u003eless than or equal to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHysteresis\u003c\/td\u003e\n\u003ctd\u003eapprox 5 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eReverse polarity and short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP68 \/ IP69K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePA and metal epoxy coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e118 x 40 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.225 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, EN IEC 60947-5-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs NBB20-U1-E0 compatible with standard PLC digital inputs?\u003c\/strong\u003e\u003cbr\u003eYes. The NPN normally open output works with most 24 V DC sinking PLC inputs including Siemens, Allen Bradley, and Schneider modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this sensor replace older Pepperl+Fuchs rectangular 20 mm sensors?\u003c\/strong\u003e\u003cbr\u003eYes. The mounting footprint and electrical characteristics allow direct replacement of most U1 series 20 mm inductive sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes unstable switching at long sensing distance?\u003c\/strong\u003e\u003cbr\u003eMetal type affects detection range. Aluminum and copper reduce sensing distance due to lower reduction factors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the sensor support washdown environments?\u003c\/strong\u003e\u003cbr\u003eYes. IP68 and IP69K protection allows use in food processing, chemical plants, and outdoor conveyors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the sensor flush with metal surface to maintain rated 20 mm sensing distance. Non-flush mounting increases switching variation.\u003c\/p\u003e\n\u003cp\u003eUse shielded cable when routing near VFD motor lines. This reduces electrical noise and false switching.\u003c\/p\u003e\n\u003cp\u003eDo not exceed 1.2 Nm terminal tightening torque. Excess torque damages screw terminals and causes intermittent signal loss.\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNBB20-U1-E0\u003c\/strong\u003e provides reliable detection in vibration-heavy machinery due to solid epoxy coated housing. The rotatable sensing head simplifies alignment in retrofits. The wide temperature range supports outdoor material handling systems.\u003c\/p\u003e\n\u003cp\u003eThe IP69K protection ensures operation in high pressure washdown areas. Internal protection circuits prevent damage from wiring mistakes. The standard 3-wire interface ensures compatibility with legacy PLC systems.\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":52668297642347,"sku":"NBB20-U1-E0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nbb20-u1-e0-s52u2gedadb_8cda3ea6-91b3-41c9-acfa-fa0dcf90df61.jpg?v=1765520450"},{"product_id":"288055-01-bently-nevada-standard-transient-data-interface-module-with-usb-cable","title":"288055-01 | Bently Nevada | Standard Transient Data Interface Module with USB cable","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e288055-01 \u003c\/strong\u003eis a 3500\/22M TDI module designed for precise condition monitoring.\u003cbr\u003eIt provides the interface between the 3500 rack and monitoring software.\u003cbr\u003eThe module integrates high-bandwidth communication processing for reliable data capture.\u003cbr\u003eIt supports static, transient, and high-resolution waveform data across all channels.\u003c\/p\u003e\n\u003ch3\u003eCore Identification\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e288055-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eStandard Transient Data Interface (TDI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3500\/22M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Slot\u003c\/td\u003e\n\u003ctd\u003eSlot 1 in 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommunication \u0026amp; Interfaces\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eFront panel USB Type-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Version\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eLocal configuration and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Communication\u003c\/td\u003e\n\u003ctd\u003eRequires compatible rear I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003e3500 proprietary rack interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eData Acquisition Capabilities\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Types\u003c\/td\u003e\n\u003ctd\u003eStatic, transient, high-resolution waveforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Mode\u003c\/td\u003e\n\u003ctd\u003eContinuous, multi-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eProcesses synchronous and asynchronous data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Storage\u003c\/td\u003e\n\u003ctd\u003eNon-volatile flash memory for configuration and event logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical \u0026amp; Shipping\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e5.0 kg (includes packaging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003eFactory-sealed, ESD-safe materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eUSB configuration cable, quick start manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch4\u003eFront-Panel USB Access\u003c\/h4\u003e\n\u003cp\u003eTechnicians connect laptops directly to the front USB port.\u003cbr\u003eRear cabinet access is not required for configuration or diagnostics.\u003c\/p\u003e\n\u003ch4\u003eHigh-Fidelity Data Streaming\u003c\/h4\u003e\n\u003cp\u003eWaveform data streams across all channels simultaneously.\u003cbr\u003eThis ensures no data loss during critical machine events.\u003c\/p\u003e\n\u003ch4\u003eTransient Data Capture\u003c\/h4\u003e\n\u003cp\u003eCaptures machine behavior during startup and coast-down.\u003cbr\u003eHelps identify resonance, rotor rubs, and bearing instability.\u003c\/p\u003e\n\u003ch4\u003eIndustrial Reliability\u003c\/h4\u003e\n\u003cp\u003eAdvanced shielding protects against electromagnetic interference.\u003cbr\u003eThe module maintains signal integrity in harsh industrial environments.\u003c\/p\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Type\u003c\/td\u003e\n\u003ctd\u003e3500\/05 or 3500\/06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot\u003c\/td\u003e\n\u003ctd\u003eSlot 1 (TDI slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003e3500 Rack Configuration Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring System\u003c\/td\u003e\n\u003ctd\u003eSystem 1 (Version 6.x or later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired I\/O Module\u003c\/td\u003e\n\u003ctd\u003eRear I\/O module, e.g., 146031-01 for Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ (Frequently Asked Questions)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 288055-01 a replacement for 138607-01?\u003c\/strong\u003e\u003cbr\u003eYes. It fits the same rack slot and offers improved performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a rear I\/O module?\u003c\/strong\u003e\u003cbr\u003eYes. Ethernet or network communication requires a compatible rear module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat data does the 288055-01 collect?\u003c\/strong\u003e\u003cbr\u003eIt collects static, transient, and high-resolution waveform data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this module installed?\u003c\/strong\u003e\u003cbr\u003eIt installs in Slot 1 of the 3500\/05 or 3500\/06 rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I verify authenticity?\u003c\/strong\u003e\u003cbr\u003eEach unit is factory-sealed with a “Made in U.S.A.” label.\u003cbr\u003eThe serial number can be verified against Bently Nevada records.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668302983531,"sku":"288055-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/288055-01-0fuojr4ph0r_75cbce1a-4770-493c-b79c-4ef3895afba2.jpg?v=1765520601"},{"product_id":"bently-nevada-3300-xl-series-21747-045-01-proximitor-extension-cable-with-armor","title":"Bently Nevada 3300 XL Series 21747-045-01 Proximitor Extension Cable with Armor","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e21747-045-01 (21747-045-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical link within the Bently Nevada 3300 and 3300 XL Proximitor Sensor systems. This specific extension cable is engineered to maintain high-fidelity signal transmission between the proximity probe and the Proximitor sensor, ensuring precise vibration and position monitoring in demanding rotating machinery environments. The inclusion of stainless steel armor provides superior mechanical protection against physical abrasion and fluid exposure common in industrial settings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e21747-045-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 Meters (Approximately 14.8 Feet \/ 177 Inches)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlexible Stainless Steel Armor (Option 01)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 and 3300 XL 5mm \u0026amp; 8mm Proximity Transducer Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial Gold-plated ClickLoc connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 °C to +177 °C (-60 °F to +350 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProper implementation of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e21747-045-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires ensuring that the combined length of the proximity probe and the extension cable matches the required system length of the Proximitor Sensor (typically 5.0 or 9.0 meters). This armored version is ideal for internal machine housing or exposed conduit runs where moisture, oil, or mechanical impact risks are present.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used with non-XL 3300 sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e21747-045-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis backward compatible with standard 3300 series 5mm and 8mm systems, provided the total electrical length is calibrated correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the '01' Armor option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stainless steel braiding prevents the coaxial core from being crushed or kinked, which would otherwise alter the electrical capacitance and degrade the accuracy of vibration data.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668310094187,"sku":"21747-045-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/21747-045-01-fsoxkziulth_7260c2c9-8728-4dd8-a6f7-5f900ae6824f.jpg?v=1765520819"},{"product_id":"3500-40-01-00-bently-nevada-3500-40m-proximitor-monitor","title":"3500\/40-01-00 | Bently Nevada | 3500\/40M Proximitor Monitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/40-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(part of the 3500\/40M series) is a high-performance four-channel monitor designed to process signals from proximity transducers. It provides essential machinery protection by continuously comparing monitored parameters against configured alarm setpoints, making it a cornerstone of vibration and position monitoring in industrial automation.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/40-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/40M Proximitor Monitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Termination\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 to 4 proximity transducer signals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e550 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 W (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C to +65 °C (-22 °F to +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +85 °C (-40 °F to +185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (D x W x H)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.18 cm x 2.44 cm x 24.13 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.91 kg (Net) \/ 2.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Engineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Channel Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcesses up to four proximity transducer signals simultaneously, enabling comprehensive multi-point vibration and radial position monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures internal terminations to streamline wiring and reduce the footprint required within industrial rack assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to maintain signal integrity in harsh conditions, operating effectively in temperatures as low as -30 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMinimal 7 W power draw reduces the thermal load on the 3500 system rack and lowers overall plant power requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Standard Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManufactured in the U.S.A. to meet the rigorous reliability standards expected in Oil \u0026amp; Gas, Power Generation, and Heavy Manufacturing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Configuration: 3500\/40-01-00\u003c\/h3\u003e\n\u003cp\u003eThe part number breaks down into the following specific options:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-27\"\u003e\u003c\/span\u003e\u003cstrong\u003e3500\/40\u003c\/strong\u003e\u003cspan class=\"citation-27 citation-end-27\"\u003e: Proximitor Monitor Main Module.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Proximitor I\/O Module with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInternal Terminations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Agency Approvals.\u003cspan\u003eKey Technical Specifications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I confirm this 3500\/40M monitor is genuine?\u003c\/strong\u003e\u003cbr\u003eVerify the part number 3500\/40-01-00 and original Bently Nevada factory labeling. Only Brand New units guarantee full specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many transducers can this module support?\u003c\/strong\u003e\u003cbr\u003eThis module accepts 1–4 proximity transducer signals, enabling flexible vibration monitoring setups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can it operate in extreme temperatures?\u003c\/strong\u003e\u003cbr\u003eYes, depending on the I\/O configuration, it operates from -30 °C to +65 °C or 0 °C to +65 °C with internal barriers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What installation considerations should I follow?\u003c\/strong\u003e\u003cbr\u003eInstall in the 3500\/40M rack slot with proper termination. Avoid exceeding humidity limits and ensure secure cabling for accurate readings.\u003c\/p\u003e\n\u003ch3\u003eCompatibility \u0026amp; Shipping\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRequired Extensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with standard Bently Nevada 3500\/40M I\/O modules and internal\/external termination options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects directly with 3500\/40M racks for plant-wide vibration and condition monitoring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShips Brand New in Original Factory Packaging. Global shipping with anti-static and secure protection for sensitive industrial electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668317892971,"sku":"3500\/40-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350040-01-00estimatedleadtime1-10workingdays-gqubsprlcvo_dc216087-d15d-4c71-a294-753ed898a34d.jpg?v=1765521086"},{"product_id":"138607-01-bently-nevada-3500-22m-standard-transient-data-interface-module","title":"138607-01 | Bently Nevada | 3500\/22M Standard Transient Data Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e138607-01 (138607-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the core\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStandard Transient Data Interface (TDI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule for the Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. As the primary communication gateway for the 3500 Machinery Protection System, this module is responsible for bridging the gap between hardware monitors and diagnostic software. Unlike standard interface modules, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to handle \"transient\" data—capturing high-resolution waveforms during machine start-up, coast-down, and steady-state operation. This capability is critical for vibration specialists to perform orbit, spectrum, and time-base analysis, ensuring the long-term reliability of high-speed rotating assets.\u003c\/p\u003e\n\u003ch3\u003eFunctional Engineering \u0026amp; Diagnostic Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M 138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the processing intelligence required to manage all monitor modules within a 3500 rack. It performs continuous self-diagnostics and manages the communication flow to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. By collecting dynamic data from the backplane, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for a \"Black Box\" forensic approach to machinery protection; it can trigger high-speed data captures based on alarm events, providing engineers with the exact vibration profiles leading up to a machine trip. This module is the \"Standard\" version, optimized for typical industrial monitoring applications where intrinsic safety barriers are handled externally.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\/22M\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e138607-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Collection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatic, Dynamic (Waveforms), and Transient Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet (via I\/O module) \u0026amp; USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-volatile flash for configuration and event logs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFront Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB port for local rack configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus LEDs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOK, TX\/RX, TM (Test Mode), and CONFIG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 138607-01 differ from the 3500\/20 RIM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe legacy 3500\/20 Rack Interface Module (RIM) only supports static data (overall vibration values). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M TDI (138607-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-bandwidth upgrade that enables the capture of raw waveforms, which is the only way to perform detailed diagnostics in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 138607-01 be installed in any slot of the 3500 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The TDI must always be installed in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efirst slot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(leftmost side, Slot 1) of the 3500 rack, immediately next to the Power Supply modules. This position is required to manage the rack-wide communication bus effectively.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the front-panel USB port?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe USB port on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLocal Configuration\u003c\/strong\u003e. It allows a field engineer to connect a laptop directly to the rack to set up sensor types, alarm setpoints, and network parameters using the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen replacing a 138607-01, ensure the firmware version matches the rest of the rack modules and your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion. Discrepancies can lead to communication errors or the inability to capture transient events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Upload:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore commissioning, the module must be \"configured.\" Connect via USB, set the specific rack address and IP settings, and then upload the configuration. The module will retain this information in its non-volatile memory even after a power loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Procedure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports replacement while the rack is powered. However, when the TDI is removed, all communication to the diagnostic software will stop. The individual monitor modules will still provide hardware-level machinery protection (trips), but remote visibility will be lost until the new module is synchronized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M 138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an essential investment for any plant operating turbines, compressors, or large pumps. Its ability to provide deep-dive forensic data makes it the gold standard for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRoot Cause Analysis (RCA)\u003c\/strong\u003e. Built for extreme industrial durability, this module ensures that your machinery protection system is not just a \"trip box\" but a powerful diagnostic tool that reduces unplanned downtime and extends the life of critical equipment.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318253419,"sku":"138607-01-2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/138607-01_bently_nevada-jovg24rn2bi_73c2f3d1-1189-4536-b724-735a9c7ce710.jpg?v=1765521098"},{"product_id":"bently-nevada-3500-22-01-01-01-288055-01-146031-01-transient-data-interface","title":"Bently Nevada 3500\/22-01-01-01 | 288055-01 +146031-01 | Transient Data Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(composed of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e288055-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emain module and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e146031-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O module) is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTransient Data Interface (TDI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Bently Nevada 3500 Machinery Protection System. The TDI is the central communication hub of the rack, serving as the essential link between the individual monitoring modules and external diagnostic software, such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e. Unlike basic interface modules, the TDI is capable of capturing high-resolution dynamic waveforms during both steady-state operation and transient events (start-ups and coast-downs), providing the deep-dive analytics required for predictive maintenance on critical rotating assets.\u003c\/p\u003e\n\u003ch3\u003eKey Components \u0026amp; Configuration\u003c\/h3\u003e\n\u003cp\u003eThis specific assembly is a \"Standard\" configuration, optimized for general industrial monitoring where specialized barriers or extreme agency approvals are not required:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMain Module (288055-01):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe core processor module, including a USB cable for direct local communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module (146031-01):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe rear-mounted interface featuring a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10Base-T\/100Base-TX Ethernet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eport for high-speed network integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOption 01 (Standard TDI):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed for standard monitoring applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOption 01 (Ethernet I\/O):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes standard RJ45 connectivity for robust data throughput.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOption 00 (No Approvals):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard version without specialized hazardous area agency certifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\/22-01-01-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMain Processor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e288055-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e146031-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet (10\/100 Mbps) \u0026amp; USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatic, Dynamic (Waveforms), and Transient\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.18 cm x 2.44 cm x 24.13 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~1.11 kg (Module 0.91kg + I\/O 0.20kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between a TDI and a standard RIM (Rack Interface Module)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile both manage the rack, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M TDI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis significantly more powerful. It is the only module capable of streaming dynamic waveform data to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. Without a TDI, you are limited to static data (overall values) and lose the ability to perform spectrum or orbit analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the USB port be used for remote data collection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The USB port provided with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e288055-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis intended for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elocal configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand maintenance using the 3500 Rack Configuration Software. Continuous plant-wide data collection must be handled through the Ethernet port on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e146031-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support internal intrinsic safety barriers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot this specific configuration. The \"01\" transient data interface type indicates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule. If your application requires internal barriers for hazardous areas, a different option code and internal hardware would be necessary.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Positioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe TDI must be installed in the slot immediately to the right of the Power Supply modules (Slot 1).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore commissioning, use the USB cable to link the TDI to a laptop running the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e. You must define the network IP address, subnet mask, and gateway before the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e146031-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet port can communicate with the plant network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the 3500 rack supports redundant power supplies, the TDI is a single-point communication gateway. Ensure your network switches are industrial-grade to prevent communication loss to your condition monitoring software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the \"Black Box\" capability for industrial machinery. In the event of a machine trip, the TDI allows engineers to retrieve the exact vibration waveforms leading up to the event, which is vital for root-cause analysis. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eU.S.A.-made\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebuild quality and ability to provide a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCertificate of Origin (COO)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emake it a preferred choice for global B2B procurement in the oil, gas, and power generation sectors where documentation and hardware reliability are paramount.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321661291,"sku":"288055-01 +146031-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350022-01-01-01288055-01-146031-01-nwwli4ezpyt_52447ece-9c82-498c-b49d-ca113d00625d.jpg?v=1765521166"},{"product_id":"bently-nevada-3500-22m-01-01-00-transient-data-interface-with-ethernet-i-o","title":"Bently Nevada 3500\/22M-01-01-00 | Transient Data Interface with Ethernet I\/O","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Transient Data Interface) is the specialized communication and data acquisition processor for the Bently Nevada 3500 series machinery protection system. Unlike the standard 3500\/20 RIM, the \"M\" series TDI provides advanced waveform capture and high-resolution transient data analysis capabilities. This module is the essential link between the rack's internal backplane and external diagnostic software, such as System 1, facilitating real-time monitoring of critical rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel ID:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransient Data Interface (TDI) Module and I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTDI Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOption\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Standard - designed for general machinery monitoring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOption\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(10Base-T\/100Base-TX Ethernet I\/O module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOption\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(None \/ General Purpose)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRJ45 Copper Interface supporting 10\/100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Refresh Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStatic data updated at 100 ms intervals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal non-volatile memory for configuration and event logging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMade in U.S.A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Net Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.11 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Shipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Role and Integration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoccupies the first slot of the 3500 rack, adjacent to the power supplies. It continuously polls data from all vibration, position, and temperature monitors within the rack. By utilizing the 10\/100 Ethernet I\/O, it ensures that high-bandwidth dynamic waveforms are transmitted without latency, which is critical for identifying rotor instability or bearing wear during transient machine states (startup, shutdown, or speed changes).\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 3500\/22M-01-01-00 compatible with older 3500 racks?\u003c\/strong\u003eA: Yes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to be backwards compatible with the 3500 rack chassis, provided the rack backplane supports the TDI architecture. It is the recommended upgrade for legacy 3500\/20 modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the \"00\" Agency Approval limit the module's performance?\u003c\/strong\u003eA: No. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption indicates the unit does not carry specific hazardous area certifications (like CSA or ATEX). It offers identical technical performance to certified units and is ideal for control rooms or non-classified industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322742635,"sku":"3500\/22M-01-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350022m-01-01-00-dak4rp3gmkm_003a628d-19ea-4202-a869-d6aedfb09e6a.jpg?v=1765521208"},{"product_id":"bently-nevada-330106-05-30-10-12-00-3300-xl-8-mm-reverse-mount-probe","title":"Bently Nevada 330106-05-30-10-12-00 3300 XL 8 mm Reverse Mount Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330106-05-30-10-12-00 \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 3300 XL 8 mm Reverse Mount Probe engineered by Bently Nevada for critical machinery protection applications. Unlike standard proximity probes, the reverse mount design is specifically intended for use with probe housings or applications where the probe is installed from the opposite side of the machine casing. This component is essential for monitoring radial vibration and axial position in high-speed turbines, large scale compressors, and industrial pumps. By providing high-fidelity displacement data to the Proximitor sensor, it enables early detection of mechanical wear and shaft instability. In industries such as power generation and oil refining, the reliability of this probe is paramount to avoiding catastrophic asset failure and significantly reducing unscheduled maintenance costs.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number configuration defines the mechanical and electrical interface for specific field requirements:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330106\u003c\/strong\u003e: Base model for the 3300 XL 8 mm Reverse Mount Probe (3\/8-24 UNF thread).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Unthreaded Length Option. Specifies 0.5 inches of unthreaded body.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e30\u003c\/strong\u003e: Overall Case Length Option. Indicates a 3.0 inch total case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option. Equipped with a 1.0 meter (3.3 feet) integrated cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: Connector and Cable Option. Features a miniature ClickLoc coaxial connector combined with a FluidLoc cable designed to prevent oil or moisture from wicking through the cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval Option. No specific hazardous area certifications required for this configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330106-05-30-10-12-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReverse Mount (3\/8-24 UNF-2A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc (Moisture\/Oil Resistant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should I choose the Reverse Mount version over a standard probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReverse mount probes are used when the installation requires the probe to be inserted through a housing (such as the Bently Nevada 21000 series) or when there is limited clearance for standard front-mount installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the FluidLoc cable option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc cable (Option 12) is designed with internal seals to prevent oil, coolants, or other process fluids from leaking through the inside of the cable and into the Proximitor sensor or junction box.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe compatible with standard 3300 XL Proximitor sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, provided the total system length (probe plus extension cable) matches the Proximitor calibration (typically 5.0 or 9.0 meters). This specific probe has a 1.0 meter length, so a 4.0 or 8.0 meter extension cable would be required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFluidLoc Handling and Cable Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc cable is slightly stiffer than standard coaxial cables due to its sealing properties. During installation, maintain a minimum bend radius of 25.4 mm (1.0 inch). Avoid using pliers on the ClickLoc connector; these are designed for finger-tight connections. A loose connector is the most common cause of \"signal spikes\" in vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReverse Mount Installation Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installing the 330106 probe into a housing, ensure the threads are clean and free of debris. Use a small amount of anti-seize compound if the environment is prone to high-temperature oxidation. Torque the probe into the housing to approximately 4.5 N-m (40 in-lb). Over-tightening can damage the internal sensor coil or the thin-wall section of the 8 mm tip.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323856747,"sku":"330106-05-30-10-12-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330106-05-30-10-12-00-3300-xl-8-mm-reverse-mount-probes-nwquobeqh33_17c62b7a-49d4-4786-87ab-db3efa956eb3.jpg?v=1765447171"},{"product_id":"330180-x1-cn-mod-145004-14-bently-nevada-3300-xl-proximitor-sensor","title":"330180-X1-CN MOD 145004-14 | Bently Nevada | 3300 XL Proximitor Sensor","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN MOD 145004-14 (330180-X1-CN-145004-14)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby Bently Nevada is a specialized 3300 XL Proximitor Sensor designed for advanced machinery protection in demanding sectors like heavy mining, offshore oil platforms, and thermal power plants. This specific MOD 145004-14 variant is factory-calibrated for AISI 1040 steel target material, ensuring maximum linearity and accuracy when standard 4140 calibration is insufficient. By converting the complex eddy current signal from the probe into a stable voltage output, this sensor enables real-time tracking of radial vibration and axial thrust. Its robust design is critical for detecting early-stage rotor imbalances and shaft misalignments, allowing operators to execute predictive maintenance and significantly reduce the probability of catastrophic machine failure or unplanned outages.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Modification Breakdown\u003c\/h3\u003e\n\u003cp\u003eEach segment of this model number represents a critical hardware or calibration specification tailored for industrial compliance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180\u003c\/strong\u003e: Base series identifier for the 3300 XL Proximitor Sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX1\u003c\/strong\u003e: Specifies the total system length and mounting hardware configuration (typically compatible with 5.0 or 9.0 meter systems).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Denotes global and regional agency approvals, including ATEX\/IECEx for explosive atmospheres and the Chinese NEPSI hazardous area certification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD 145004-14\u003c\/strong\u003e: Indicates a factory-level modification for non-standard requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e14\u003c\/strong\u003e: Target Material Calibration. This unit is specifically tuned for AISI 1040 steel targets, adjusting the scale factor to maintain the standard 7.87 V\/mm (200 mV\/mil) output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEssential Hardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-X1-CN MOD 145004-14\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 1040 Steel (Custom Calibration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Scale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-17.5 VDC to -26 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-52 to 100 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX, IECEx, NEPSI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecialist Inquiry \u0026amp; Support\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is AISI 1040 calibration necessary for this MOD version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard Bently Nevada sensors are calibrated for AISI 4140 steel. If your shaft material is AISI 1040, using a standard sensor would result in significant linearity errors and incorrect vibration readings. This MOD version ensures the 200 mV\/mil output remains accurate for the specific metallurgy of your machine.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this Proximitor be mounted in a high-vibration area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 3300 XL series is robust, it should ideally be mounted in a weather-tight housing (like a 3300 XL internal or external housing) to shield it from direct environmental impact and excessive structural vibration, ensuring long-term signal stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with non-XL 3300 probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL Proximitor is designed for use with 3300 XL probes; however, it provides backward compatibility with some non-XL 3300 5 mm and 8 mm probes. Always verify total system length (5 m or 9 m) before commissioning.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Protocol\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo prevent EMI (Electromagnetic Interference) from distorting the vibration signal, the coaxial cable shield must be isolated from the machine ground. Ensure the Proximitor is mounted on a DIN rail that is properly bonded to a clean instrument ground. Failure to maintain a single-point ground can lead to \"noise\" that the monitoring system may misinterpret as actual machinery vibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Material Sensitivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince this unit is modified for AISI 1040 steel (MOD 145004-14), ensure that the probe is not installed on a shaft made of 4140 or other alloys. Using the wrong calibration will cause a Scale Factor Error (SFE). We recommend verifying the shaft material via the original equipment manufacturer (OEM) documentation prior to replacing existing sensors with this modified version.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323889515,"sku":"145004-14","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330180-x1-cn-mod-145004-14-azh4mdn1qhi_909cbd1b-cb4a-461a-b55e-44f40171d56c.jpg?v=1765521250"},{"product_id":"330171-00-20-05-02-cn-bently-nevada-3300-5-mm-proximity-probe-1-4-28-unf","title":"330171-00-20-05-02-CN Bently Nevada 3300 5 mm Proximity Probe (1\/4-28 UNF)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330171-00-20-05-02-CN\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e is a precision-engineered 3300 5 mm Proximity Probe featuring a 1\/4-28 UNF thread, specifically designed by Bently Nevada for high-accuracy displacement monitoring. This non-armored transducer is optimized for tight mechanical clearances where a standard 8 mm probe is too large to interface with the machine casing. It is extensively utilized in critical rotating machinery—such as high-speed compressors, small steam turbines, and pumps—to monitor radial vibration and axial position. By providing reliable data to the Machinery Protection System (MPS), the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330171-00-20-05-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplays a fundamental role in detecting rotor imbalances and bearing degradation, ensuring operational safety and preventing costly unplanned outages.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThis specific configuration of the 3300 5 mm probe is defined by the following technical parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330171\u003c\/strong\u003e: Base model for the 3300 5 mm Proximity Probe with 1\/4-28 UNF mounting threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded Length. Indicates that the probe body has 0.0 inches of unthreaded section; the entire case is threaded.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20\u003c\/strong\u003e: Overall Case Length. The total length of the probe housing is 2.0 inches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total Length. The integrated probe cable length is 0.5 meter (1.6 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector Option. Equipped with a miniature coaxial ClickLoc connector for secure, low-loss signal transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Agency Approval. Specifically certified for the Chinese market, meeting regional hazardous area and safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330171-00-20-05-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4-28 UNF-2A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mm (0.197 inches)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor (Standard Cable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 to 1.25 mm (10 to 50 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to 177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 Steel (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I identify the 1\/4-28 UNF thread version versus the 3\/8-24 version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 330171 base model number specifically denotes the 1\/4-28 UNF thread series. The smaller diameter of the 1\/4-inch thread is visually distinct and is intended for machines with smaller tapped ports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the consequences of using a non-armored cable in an industrial setting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNon-armored probes like the 330171-00-20-05-02-CN are easier to route through tight conduits but lack the mechanical protection against crushing or abrasion. It is recommended to install these within protective conduit or internal machine housings to prevent cable damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the \"CN\" version compatible with international Proximitor sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the electrical characteristics of the \"CN\" approved probe are identical to the standard version. It remains fully compatible with 3300 XL and standard 3300 Proximitor sensors, provided the total system length is matched.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Torque and Thread Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDue to the smaller 1\/4-28 UNF thread size, installers must exercise caution not to exceed the maximum torque limit (typically 3.4 N-m or 30 in-lb). Over-torquing can strip the threads or damage the internal transducer coil. Always use a thread lubricant that is compatible with the operating environment to prevent galling during future removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Gapping for 5 mm Systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5 mm probe has a narrower linear range (approx. 50 mils) compared to 8 mm systems. For a standard -24 VDC system, the target gap voltage should typically be set at -6.0 VDC to ensure the probe operates within the most linear portion of its curve. Verify the \"Field Notification Letter\" for any specific \"CN\" calibration offsets if applicable.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323922283,"sku":"330171-00-20-05-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330171-00-20-05-02-cn-z4ew0vplpog_98d65a8d-949e-4170-aa49-165c9d5730d7.jpg?v=1765521251"},{"product_id":"21000-34-05-00-028-01-02-bently-nevada-proximity-probe-housing-assembly","title":"21000-34-05-00-028-01-02 Bently Nevada Proximity Probe Housing Assembly","description":"\u003ch3\u003eProduct Summary\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e21000-34-05-00-028-01-02 (21000-34-05-00-028-01-02)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby Bently Nevada is a high-precision sensor enclosure designed for critical machinery protection in harsh industrial environments such as oil refineries, petrochemical plants, and power generation facilities. This assembly provides a robust, explosion-proof interface for the 3300 XL 8 mm proximity probe, ensuring reliable vibration and position monitoring of rotating shafts. By protecting the sensitive transducer components from mechanical damage and environmental contaminants, this housing assembly plays a vital role in preventing catastrophic machine failure and minimizing unscheduled downtime in high-stakes asset management programs.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric string for this assembly defines specific physical and certification parameters essential for field installation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e21000\u003c\/strong\u003e: Base model for the Proximity Probe Housing Assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e34\u003c\/strong\u003e: Probe Option. Integrated with a 3300 XL 8 mm probe, featuring a connector protector and multiple hazardous area approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Probe Cable Length. Equipped with a 0.5 meter (20 inch) cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Standoff Adapter Option. Indicates no standoff adapter is used in this configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e028\u003c\/strong\u003e: Probe Penetration. Specifies a total penetration depth of 2.8 inches into the machine case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Fittings Option. Configured with one explosion-proof fitting and one sealing plug.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Mounting Thread. Features 3\/4-14 NPT threads, engineered for secure mechanical coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21000-34-05-00-028-01-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Proximity Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 meter (20 inches)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePenetration Depth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.8 inches (71.1 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/4-14 NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFittings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Explosion-proof Fitting \/ 1 Plug\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to 177 deg C (Probe Tip)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple Approvals (ATEX, CSA, IECEx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I adjust the probe gap within this housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe gap must be set by loosening the internal locking mechanisms and rotating the probe until the desired DC gap voltage is achieved (typically -9.0 VDC for a mid-scale setting on 3300 XL systems). Always use a calibrated voltmeter for this procedure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this assembly be used in Class I, Division 1 environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 01 fitting option provides the necessary explosion-proof housing integrity required for hazardous locations, provided the installation follows the specified wiring and conduit sealing codes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the connector protector in the 34 option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe connector protector prevents the coaxial connection between the probe and the extension cable from loosening due to vibration and protects it from moisture ingress, which is a common cause of signal drift or failure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eField Gap Calibration and Voltage Settings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring installation, engineers must ensure the probe is gapped correctly relative to the target material (typically 4140 steel). For the Bently Nevada 3300 XL 8 mm probe, the standard linear range is 2.0 mm (80 mils). A mechanical feeler gauge or the \"Gap Voltage\" method via the Proximitor Sensor output is required. Ensure the locknut is torqued to specification after gapping to prevent drift caused by thermal expansion or machine vibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Durability and Sealing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 21000 series housing is designed for extreme durability. However, in applications involving high chemical volatility or steam, ensure the NPT mounting threads are treated with a suitable conductive anti-seize compound. The explosion-proof fitting must be sealed with certified potting compound or glands to maintain the hazardous area rating integrity of the enclosure.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323955051,"sku":"21000-34-05-00-028-01-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/21000-34-05-00-028-01-02-caet1y53tyx_0208a6fc-285c-489d-82b9-40421ad922c7.jpg?v=1765521252"},{"product_id":"330102-00-40-10-11-cn-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330102-00-40-10-11-CN Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330102-00-40-10-11-CN (330102-00-40-10-11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a cornerstone component of the Bently Nevada 3300 XL 8 mm Proximity Transducer System. This eddy-current probe is specifically engineered for non-contact measurement of static and dynamic shaft displacement, including radial vibration, axial thrust position, and speed\/keyphasor applications. Featuring a 3\/8-24 UNF threaded body and integrated stainless steel armor, this probe is designed to withstand the turbulent conditions inside industrial machinery housings. By delivering high-linearity signals to a 3300 XL Proximitor Sensor, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330102-00-40-10-11-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables precise condition monitoring for critical rotating assets such as steam turbines, centrifugal compressors, and cooling tower fans, effectively preventing catastrophic failures through early mechanical fault detection.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330102-00-40-10-11-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by the following technical configurations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330102\u003c\/strong\u003e: 3300 XL 8 mm Probe with 3\/8-24 UNF threads and factory-installed stainless steel armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Unthreaded Length)\u003c\/strong\u003e: 0.0 inches; the probe case is fully threaded for maximum mounting flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e40 (Overall Case Length)\u003c\/strong\u003e: 4.0 inches total housing length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10 (Total Length)\u003c\/strong\u003e: 1.0 meter (3.3 feet) integrated cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e11 (Connector\/Cable Type)\u003c\/strong\u003e: Equipped with the miniature coaxial ClickLoc connector and includes connector protectors for enhanced interface durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN (Agency Approval)\u003c\/strong\u003e: Certified for hazardous areas under Chinese NEPSI standards and international compliance protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330102-00-40-10-11-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 mm (0.31 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.8 bar (70 psi) tip to case\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e302\/304 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this probe require a specific extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330102-00-40-10-11-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be used with a 3300 XL extension cable. For a 1.0-meter probe, a 4.0-meter or 8.0-meter extension cable is typically used to reach a total system length of 5.0 or 9.0 meters, matching the Proximitor Sensor's calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the ClickLoc connector (Option 11)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector features a robust, moisture-resistant design that \"clicks\" when fully seated, preventing accidental disconnection due to vibration and ensuring a low-impedance electrical path for the RF signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe compatible with older 3300 series Proximitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 3300 XL 8 mm probe is physically compatible with non-XL 3300 systems, it is highly recommended to use the complete 3300 XL system to achieve the advertised 7.87 V\/mm (200 mV\/mil) linearity and improved thermal stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Gapping and Linearity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring installation, the probe must be positioned within its linear range. Connect a digital multimeter to the Proximitor output and adjust the probe position until the \"Gap Voltage\" reads approximately -10 VDC (the midpoint of the -2 to -18 VDC linear range). Ensure the locknut is torqued correctly to prevent the probe from \"backing out\" during machine operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMagnetic Side-Loading and Clearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo prevent \"side-loading\" or interference with the measurement signal, maintain a minimum clearance of two tip diameters (16 mm) between the probe tip and any surrounding conductive material other than the target shaft. Failure to provide adequate clearance will result in an incorrect scale factor and non-linear vibration readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection and Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated stainless steel armor protects the coaxial cable from mechanical abrasion and light crushing. However, avoid routing the cable near high-voltage AC lines. Use the provided connector protectors to prevent oil and moisture ingress at the probe-to-extension cable junction, as contamination is the leading cause of signal \"noise\" or false alarms.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323987819,"sku":"330102-00-40-10-11-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330102-00-40-10-11-cn-5zkset0tht3_87cec66c-add1-4aee-9d26-7ff46fee7e11.jpg?v=1765521254"},{"product_id":"bently-nevada-3300-xl-25-mm-proximity-probe-330851-02-000-060-10-00-cn","title":"Bently Nevada 3300 XL 25 mm Proximity Probe 330851-02-000-060-10-00-CN","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330851-02-000-060-10-00-CN (330851-02-000-060-10)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty 25 mm eddy-current proximity probe from Bently Nevada's renowned 3300 XL series.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for large-scale rotating machinery,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis probe is designed to measure vibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edifferential expansion,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand thrust position in environments where standard 8 mm probes lack the necessary linear range.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 25 mm tip provides an extended measurement envelope,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it the primary choice for monitoring large steam turbines and compressors in power generation and heavy industrial sectors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy delivering precise,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003enon-contact displacement data,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330851-02-000-060-10-00-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallows for the early detection of rotor instabilities,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprotecting high-value assets from catastrophic failure and optimizing maintenance intervals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSuffix Logic Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe specific hardware configuration for this\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e3300 XL 25 mm\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprobe is detailed below:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e330851\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBase model for the 3300 XL 25 mm Proximity Probe.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e02 (Probe Case Type)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a metric M30x2 threaded case for robust mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e000 (Unthreaded Length)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0 mm unthreaded portion; the case is fully threaded.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e060 (Overall Case Length)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTotal housing length of 60 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e10 (Total Length)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 meter (3.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 feet) integrated cable length.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e00 (Armor Option)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard cable without stainless steel armor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCN (Agency Approval)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIncludes specific regional hazardous area certifications for the Chinese market (NEPSI).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-02-000-060-10-00-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM30 x 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.7 mm (500 mils) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.787 V\/mm (20 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to 177 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 13.8 bar (200 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS) tip \/ Stainless steel case\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.23 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhen should I choose a 25 mm probe over a standard 8 mm probe?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe 25 mm probe is used when the expected target movement exceeds the 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 mm range of an 8 mm probe.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is ideal for measuring \"Differential Expansion\" on large turbines where the shaft grows significantly relative to the casing during thermal cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIs this probe compatible with standard 3300 XL Proximitor sensors?\u003c\/strong\u003e\u003cspan class=\"\"\u003eNo.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330851\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eseries must be used with a dedicated 3300 XL 25 mm Proximitor Sensor.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe electrical characteristics and scale factor (20 mV\/mil) differ significantly from standard 200 mV\/mil systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes the \"No Armor\" option affect the signal quality?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe lack of armor (Option 00) does not impact electrical performance or signal integrity.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit is recommended for installations where the cable is fully protected by conduit or located in areas with no risk of mechanical abrasion.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCalibration and Target Material\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330851-02-000-060-10-00-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis factory-calibrated for AISI 4140 steel.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf your application involves a different shaft material,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe scale factor may shift.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAlways perform a field calibration check using a spindle micrometer to verify the voltage-to-distance curve before finalizing the DCS\/PLC alarm setpoints.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eGap Voltage Setting\u003c\/strong\u003e\u003cspan\u003eFor thrust and vibration measurements,\u003c\/span\u003e\u003cspan\u003e the probe must be \"gapped\" correctly within its linear range.\u003c\/span\u003e\u003cspan\u003e Typically,\u003c\/span\u003e\u003cspan\u003e a gap voltage of approximately -10 VDC (center of the linear range) is desired.\u003c\/span\u003e\u003cspan\u003e Use a high-impedance digital multimeter to measure the voltage at the Proximitor \"OUT\" and \"COM\" terminals during installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChemical and Pressure Resistance\u003c\/strong\u003e\u003cspan\u003eThe probe tip is constructed from PPS,\u003c\/span\u003e\u003cspan\u003e which offers excellent resistance to most industrial lubricants and solvents.\u003c\/span\u003e\u003cspan\u003e While rated for 13.\u003c\/span\u003e\u003cspan\u003e8 bar,\u003c\/span\u003e\u003cspan\u003e ensure that the O-ring seals on the M30 threads are compatible with the machine's oil type to prevent leaks at the mounting point.\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324020587,"sku":"330851-02-000-060-10-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330851-02-000-060-10-00-cn-q5jzpkqmafk_ce40fd66-0bd5-44b8-bf28-2f34d234925d.jpg?v=1765521255"},{"product_id":"74712-06-05-04-00-bently-nevada-high-temperature-two-wire-transducer","title":"74712-06-05-04-00 Bently Nevada High-Temperature Two-Wire Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty, high-temperature seismic velocity transducer engineered by Bently Nevada for the most demanding industrial environments. Specifically designed to monitor vibration on gas turbines, steam turbines, and other rotating machinery where surface temperatures exceed the limits of standard sensors, this two-wire transducer provides a self-generated electrical signal proportional to vibration velocity. Its robust construction ensures reliable performance in the high-heat zones of power generation and petrochemical facilities, allowing for continuous monitoring of critical assets to prevent costly mechanical failure and extend the Mean Time Between Failures (MTBF).\u003c\/p\u003e\n\u003ch3\u003eSuffix Logic Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe specific hardware configuration for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by the following industrial options:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e74712\u003c\/strong\u003e: Base model for the High-Temperature Two-Wire Velocity Transducer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-90\"\u003e\u003c\/span\u003e\u003cstrong\u003e06 (Mounting Angle\/Freq Option)\u003c\/strong\u003e\u003cspan class=\"citation-90 citation-end-90\"\u003e: Optimized for a mounting angle of 0 plus or minus 100 degrees, with a minimum operating frequency of 10 Hz (600 cpm).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Mounting Base Option)\u003c\/strong\u003e: Supplied without a base; features a direct 1\/2-in 20 UNF-3A integrated stud for rigid mechanical coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04 (Connector Option)\u003c\/strong\u003e: Configured with a side-mount connector interface, ideal for installations with limited vertical overhead clearance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Agency Approval Option)\u003c\/strong\u003e: Standard non-certified version for general industrial use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e74712-06-05-04-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-Wire Velocity Transducer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin Operating Freq\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz (600 cpm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Angle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 +\/- 100 degrees\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Stud\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-in 20 UNF-3A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSide Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e41 mm (1.6 in) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.48 kg (1.06 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn what specific scenarios is a side-mount connector (Option 04) preferred?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe side-mount configuration is critical for turbine housings or bearing pedestals where the surrounding heat shielding or acoustic enclosures provide insufficient vertical space for a top-exit cable. It also assists in creating a natural \"drip loop\" to prevent moisture from following the cable into the connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transducer require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-89\"\u003eAs a velocity transducer based on moving-coil technology, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan class=\"citation-89 citation-end-89\"\u003e\u003cspan\u003e \u003c\/span\u003eis self-generating.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt converts mechanical vibration directly into a voltage signal, which simplifies field wiring and reduces the risk of electronic component failure in high-heat zones.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 10 Hz minimum frequency?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis frequency rating ensures the sensor is tuned to capture the fundamental rotational speeds and primary harmonics of large-scale turbines (600 rpm and above). It is not recommended for very slow-speed machinery where frequencies drop below 10 Hz.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Isolation and Cable Selection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis rated for high temperatures, the longevity of the installation depends heavily on the cabling. Always use high-temperature TFE-insulated shielded cables. Ensure the side-mount connector is securely tightened and, if necessary, protected by a heat-reflective sleeve to prevent localized \"hot spots\" from degrading the connector seals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Integrity and Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1\/2-in 20 UNF stud (Option 05) provides a massive, rigid connection point necessary for accurate seismic vibration transmission. Ensure the mounting surface is machined flat to a 0.001-inch total indicator reading. Apply appropriate torque to prevent the sensor from loosening under high-vibration conditions, as any \"sensor rattle\" will manifest as high-frequency noise in the vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrientation Awareness\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"06\" option is designed for near-horizontal mounting. Significant deviation from the specified mounting angle (outside the +\/- 100-degree range) can cause the internal moving coil to contact the housing walls, resulting in \"clipped\" signals and inaccurate vibration readings. Always verify the machine surface angle before installation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324053355,"sku":"74712-06-05-04-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-06-05-04-00-g0ib0cc4duz_7b5a4c3a-dec7-4315-957f-3f91417ce102.jpg?v=1765521256"},{"product_id":"330180-x1-cn-mod-145004-39-bently-nevada-3300-xl-proximitor-sensor","title":"330180-X1-CN MOD 145004-39 Bently Nevada 3300 XL Proximitor Sensor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330180-X1-CN MOD 145004-39 (330180-X1-CN)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized high-performance Proximitor Sensor within the Bently Nevada 3300 XL series.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs the core signal processing unit of an eddy-current proximity probe system,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis sensor converts the complex radio frequency (RF) signal from the probe into a linear voltage proportional to the distance between the probe tip and the target shaft.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specific\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eMOD 145004-39\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evariant is factory-calibrated for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e42 Cr Mo 4\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e(Chromium-Molybdenum steel),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring superior linearity and accuracy for turbine and compressor monitoring where non-standard shaft materials are utilized.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy providing precision vibration and position data to a 3500 rack or DCS,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit serves as a frontline defense against catastrophic machine failure in oil and gas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epower generation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand heavy manufacturing sectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330180-X1-CN MOD 145004-39\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its unique calibration and certification parameters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e3300 XL Series:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe industry standard for proximity sensing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering improved EMI\/RFI immunity and better thermal stability over previous generations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eX1 (Total Length \u0026amp; Mounting):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConfigured for specific system length requirements (standard 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 or 9.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 meters) to ensure impedance matching with the probe and extension cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMOD 145004-39:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eA critical factory modification.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhile standard sensors are calibrated for AISI 4140 steel,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis unit is specifically tuned for the electromagnetic properties of\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e42 Cr Mo 4\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ealloy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCN (Agency Approval):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFully certified for explosive atmospheres,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecarrying ATEX,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIECEx,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Chinese NEPSI hazardous area markings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-X1-CN MOD 145004-39\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42 Cr Mo 4 (Special Calibration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-17.5 VDC to -26 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Sensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +100 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePBT (Polybutylene Terephthalate) \/ A380 Aluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX, IECEx, NEPSI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan I use this sensor with a shaft made of AISI 4140 steel?\u003c\/strong\u003e\u003cspan class=\"\"\u003eWhile it will function,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe calibration is specifically tuned for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e42 Cr Mo 4\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUsing it with 4140 steel will result in a scale factor error.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor maximum accuracy,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe Proximitor calibration must match the metallurgical properties of the target material.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the significance of the \"CN\" approval for my facility?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe \"CN\" suffix ensures the device is legally compliant for installation in hazardous zones within China (NEPSI) as well as international projects requiring ATEX\/IECEx certification.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt confirms the device will not act as an ignition source in explosive gas atmospheres.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes this Proximitor require a specific probe type?\u003c\/strong\u003e\u003cspan class=\"\"\u003eYes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit must be used with a 3300 XL 8mm proximity probe and a matching 3300 XL extension cable.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the total system length (Probe + Cable) matches the Proximitor's electrical length (X1 option).\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCalibration and Material Matching\u003c\/strong\u003e\u003cspan class=\"\"\u003eSince this unit features the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eMOD 145004-39\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e42 Cr Mo 4\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit is vital that the maintenance team marks the junction box clearly.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInstalling a standard Proximitor on a 42 Cr Mo 4 shaft—or vice versa—will cause an error in the vibration amplitude readings,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epotentially leading to missed alarms or false trips.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Grounding\u003c\/strong\u003e\u003cspan\u003eThe Proximitor can be DIN-rail mounted or installed on a traditional bulkhead.\u003c\/span\u003e\u003cspan\u003e Ensure the Proximitor is housed in an environmental enclosure (such as a 3300 XL fiberglass housing) if located near the cooling tower or in an area with high chemical exposure.\u003c\/span\u003e\u003cspan\u003e The sensor base should be electrically isolated from the cabinet backplate unless a common ground strategy is explicitly required by your site's engineering standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLead Wire Integrity\u003c\/strong\u003e\u003cspan\u003eWhen connecting the field wiring to the Proximitor terminals (Signal,\u003c\/span\u003e\u003cspan\u003e COM,\u003c\/span\u003e\u003cspan\u003e and VT),\u003c\/span\u003e\u003cspan\u003e ensure the wires are stripped to the correct length and tightly secured.\u003c\/span\u003e\u003cspan\u003e Loose connections are the primary cause of \"Signal Spiking\" in TSI (Turbine Supervisory Instrumentation) systems.\u003c\/span\u003e\u003cspan\u003e Avoid routing Proximitor output cables in the same conduit as high-voltage AC power lines to prevent electromagnetic interference.\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324086123,"sku":"145004-39","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330180-x1-cn-mod-145004-39-umn21ydiptt_3e20fd48-8ad1-4e09-a318-97f6f910b918.jpg?v=1765521257"},{"product_id":"149986-01-149992-01-bently-nevada-3500-33-spare-16-channel-relay-control-module","title":"149986-01 + 149992-01 Bently Nevada 3500\/33 Spare 16-Channel Relay Control Module","description":"\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e149986-01 + 149992-01 (149986-01\/149992-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombination constitutes the complete 16-Channel Relay Module assembly for the Bently Nevada 3500 Series Machinery Protection System. This full-height solution consists of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e149986-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMain Control Module and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e149992-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOutput Termination Module.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-58 citation-end-58\"\u003eDesigned to provide high-density alarming capabilities, this system allows for 16 independent relay outputs that can be programmed with complex \"voting logic\" via the 3500 Rack Configuration Software.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-57 citation-end-57\"\u003eBy utilizing AND\/OR logic gates, plant engineers can trigger protective actions based on Alert, Danger, or Not-OK statuses from any monitor channel within the rack.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis modular relay system is a critical component for automated machinery shutdown, protecting multi-million dollar assets in power plants, refineries, and offshore platforms from catastrophic mechanical failure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem is designed for maximum flexibility and reliability in industrial control:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-56\"\u003e\u003c\/span\u003e\u003cstrong\u003eLogic Integration:\u003c\/strong\u003e\u003cspan class=\"citation-56 citation-end-56\"\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 16 channels features independent Alarm Drive Logic, capable of processing individual measured variables or combinations of monitor channels.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-55\"\u003e\u003c\/span\u003e\u003cstrong\u003eOperational Modes:\u003c\/strong\u003e\u003cspan class=\"citation-55 citation-end-55\"\u003e\u003cspan\u003e \u003c\/span\u003eRelays are organized into four groups of four channels.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEach group is switch-selectable for Normally De-energized (ND) or Normally Energized (NE) \"Failsafe\" operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-54\"\u003e\u003c\/span\u003e\u003cstrong\u003eStandard Contact Construction:\u003c\/strong\u003e\u003cspan class=\"citation-54 citation-end-54\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures epoxy-sealed Single-Pole Double-Throw (SPDT) relays with built-in 250 Vrms arc suppressors to ensure long-term contact integrity.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-53\"\u003e\u003c\/span\u003e\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e\u003cspan class=\"citation-53 citation-end-53\"\u003e\u003cspan\u003e \u003c\/span\u003eThe front panel includes high-visibility LEDs for module \"OK\" status, TX\/RX communication flashes, and individual Channel Alarm indicators for real-time troubleshooting.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e149986-01 (Control) + 149992-01 (Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/33 Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Channel SPDT (Single-Pole Double-Throw)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.8 watts typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switched Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A (Resistive Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switched Voltage (AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Vac\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switched Voltage (DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 Vdc (Standard) \/ 30 Vdc (Failsafe\/Haz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEpoxy-sealed Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241 mm x 24.4 mm x 242 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 kg (1.6 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install the 16-channel relay module in any rack slot?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be placed in any of the slots in the 3500 rack, provided they are to the right of the Transient Data Interface (TDI) Module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the software requirements for this specific hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo utilize the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e149986-01\u003c\/strong\u003e, your system must run 3500 Rack Configuration Software version 3.3 or later, and Data Acquisition Software version 2.40 or later.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the voltage rating lower for SIL or Hazardous Area systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn Failsafe or Multiple Approval (-02) systems, the maximum switched voltage is de-rated to 30 Vdc\/Vrms to comply with ATEX and North American Zone 2 spacing requirements and 61010-1 safety type tests.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eContact Load Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-52\"\u003eFor standard silver contacts used in the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e149986-01\u003c\/strong\u003e\u003cspan class=\"citation-52 citation-end-52\"\u003e, the minimum switched load is 100 mA @ 5 Vdc.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIf your control circuit operates at lower currents (e.g., interfacing with high-impedance digital inputs), ensure you are using the Low Current (gold-plated) variant to prevent contact oxidation and intermittent signaling. For gold-plated contacts, do not exceed 5 mA to avoid damaging the plating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArc Suppression and Inductive Loads\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module includes standard 250 Vrms arc suppressors, we strongly recommend installing external flyback diodes (for DC) or varistors (for AC) when driving high-inductance solenoid valves. This reduces EMI and extends the relay contact life beyond the rated 10,000 cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility and Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf this module is integrated into a Functional Safety (SIL) loop, you must strictly adhere to the restricted voltage limits specified in the safety certificate. Exceeding 30 Vdc in a hazardous area application violates the equipment's certification and may create a spark hazard. Always verify the \"Normally Energized\" vs \"Normally De-energized\" switch positions before powering the rack to prevent accidental machine trips during commissioning.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324151659,"sku":"149986-01ÿ+149992-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/149986-01_149992-01-35nvljlewoh.jpg?v=1765519475"},{"product_id":"330930-065-05-cn-bently-nevada-3300-xl-nsv-proximity-extension-cable","title":"330930-065-05-CN Bently Nevada 3300 XL NSv Proximity Extension Cable","description":"\u003ch3 class=\"\"\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN \u003c\/strong\u003e\u003cspan class=\"\"\u003eis a high-performance extension cable designed specifically for the Bently Nevada 3300 XL NSv (Narrow Side view) Proximity Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specialized cable serves as the critical signal link between the proximity probe and the Proximitor Sensor,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaintaining impedance matching and signal integrity in demanding industrial environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for applications with tight spatial constraints where standard proximity probes cannot be used,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as small centrifugal compressors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epumps,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand motors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy ensuring precise transmission of eddy-current signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis cable facilitates accurate vibration and position monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edirectly contributing to the mechanical health and safety of high-speed rotating assets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis configured according to the following technical specifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e330930\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBase model for the 3300 XL NSv Extension Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e065 (Cable Length Option)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e6.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 meters (21.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 feet).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis length is specifically calibrated to match the system's electrical requirements for a total 7.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter or 9.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter system length.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e05 (Connector and Cable Option)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with heavy-duty stainless steel armor for superior mechanical protection; supplied without FEP jacket; includes factory-installed connector protectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCN (Agency Approval Option)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCertified for use in hazardous areas with ATEX\/IECEx and Chinese NEPSI markings,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring compliance with global and regional safety standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-065-05-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL NSv Proximity System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 g\/m (0.5 oz\/ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (AISI 302\/304)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area Marking\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX, IECEx, NEPSI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan this extension cable be used with a standard 3300 XL 8mm probe?\u003c\/strong\u003e\u003cspan class=\"\"\u003eNo.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis designed exclusively for the NSv system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUsing it with standard 5mm or 8mm systems will result in incorrect impedance matching and significant measurement errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the purpose of the stainless steel armor (Option 05)?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe armor provides high physical durability against crushing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eabrasion,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand rodent damage in industrial environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esince this version lacks the FEP jacket,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit is best suited for environments where chemical exposure is not the primary concern.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAre the connector protectors removable?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe connector protectors are designed to prevent the connectors from being damaged or contaminated during the \"pulling\" process through conduit.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThey should be used during installation and can be removed for final mating.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Integrity and Connector Maintenance\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe coaxial connectors on the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eare sensitive to moisture and oil.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAlways ensure connectors are clean and dry before mating.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWe recommend using a torque wrench specifically designed for proximity system connectors (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e45 N-m or 4 in-lb) to prevent over-tightening,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich can deform the center pin and lead to intermittent signal loss or \"spiking.\u003c\/span\u003e\u003cspan class=\"\"\u003e\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInstallation in Hazardous Areas\u003c\/strong\u003e\u003cspan class=\"\"\u003eAs a NEPSI and ATEX certified component,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis cable must be installed in accordance with the specific \"Conditions of Safe Use\" outlined in the certification documentation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the stainless steel armor is properly bonded to the machine ground at the bulkhead or junction box to prevent electrostatic buildup or potential differences in hazardous atmospheres.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCable Routing Limits\u003c\/strong\u003e\u003cspan class=\"\"\u003eWhile the stainless steel armor is robust,\u003c\/span\u003e\u003cspan\u003e observe the minimum bend radius of 25.\u003c\/span\u003e\u003cspan\u003e4 mm (1.\u003c\/span\u003e\u003cspan\u003e0 inch).\u003c\/span\u003e\u003cspan\u003e Kinking the cable will change its coaxial capacitance,\u003c\/span\u003e\u003cspan\u003e permanently altering the calibration of the entire proximity system and necessitating replacement of the cable to restore accuracy.\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324282731,"sku":"330930-065-05-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-065-05-cn-zw40ihoeo2y_07b1c5aa-d20e-4c0e-9876-b628f171d888.jpg?v=1765521259"},{"product_id":"190501-01-00-cn-bently-nevada-velomitor-ct-velocity-transducer","title":"190501-01-00-CN Bently Nevada Velomitor CT Velocity Transducer","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-25\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e190501-01-00-00 (190501-01-00)\u003c\/strong\u003e\u003cspan class=\"citation-25 citation-end-25\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized low-frequency version of the industry-standard Velomitor Piezo-velocity Sensor.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEngineered by Bently Nevada for high-precision machinery protection, this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVelomitor CT (Cooling Tower)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransducer is optimized to measure casing vibration velocity on cooling tower fans and air-cooled heat-exchanger assemblies. It is specifically designed for equipment operating at or above 90 rpm (typically 100 to 300 rpm).\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-24\"\u003eBy capturing vibration frequencies generated by both the fan motor and the speed reducer, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e190501-01-00-00\u003c\/strong\u003e\u003cspan class=\"citation-24 citation-end-24\"\u003e\u003cspan\u003e \u003c\/span\u003eallows plant operators to detect early-stage mechanical wear, preventing catastrophic failures and significantly reducing unplanned downtime in power generation and industrial processing plants.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e190501-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefines the specific hardware and certification configuration as follows:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-23\"\u003e\u003c\/span\u003e\u003cstrong\u003e190501\u003c\/strong\u003e\u003cspan class=\"citation-23 citation-end-23\"\u003e: Base Model for the Velomitor CT Velocity Transducer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01 (Mounting Hardware Option)\u003c\/strong\u003e: Provided with a 3\/8-in 24 to 3\/8-in 24 mounting stud for secure mechanical attachment to the machine casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-22\"\u003e\u003c\/span\u003e\u003cstrong\u003e00 (Connection Option)\u003c\/strong\u003e\u003cspan class=\"citation-22 citation-end-22\"\u003e: Features a top-mounted, 2-pin MIL-C-5015 connection interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Agency Approval Option)\u003c\/strong\u003e: Standard configuration without specific hazardous area certifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e190501-01-00-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 Hz to 1.0 kHz (90 to 60,000 cpm) +\/- 3.0 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVelocity Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63.5 mm\/s pk (2.5 in\/s pk)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Bias Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.1 Vdc +\/- 1.0 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e316L Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 N-m (40 in-lbf)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShock Limit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5000 g pk, maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 297 g (10.5 oz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Velomitor CT differ from a standard Piezo-velocity sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-21 citation-end-21\"\u003eThe CT (Cooling Tower) version is specifically tuned for lower frequencies (down to 1.5 Hz), making it ideal for the slow rotational speeds of cooling tower fans where standard sensors lack sufficient sensitivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transducer be mounted at any angle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e190501-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports any mounting orientation, allowing for flexible installation on both horizontal and vertical gearboxes or motor casings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cabling is recommended for signal integrity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the maximum cable length is 305 m, a recommended length of 219 m (720 ft) is advised for high-frequency vibration (1 kHz) to prevent signal degradation due to cable capacitance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSurface Preparation and Mounting Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-20 citation-end-20\"\u003eTo ensure accurate data acquisition, the mounting surface must be a 33 mm (1.3 in) diameter flat area.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUse a mounting torque of exactly 4.5 N-m (40 in-lbf). Under-torquing leads to poor high-frequency response, while over-torquing can damage the 316L stainless steel base or internal piezo-elements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Durability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e190501-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for 100% condensing humidity environments, common in cooling tower interiors. However, it is not rated for submerged operation. For maximum longevity in chemical-laden cooling tower plumes, ensure the MIL-C-5015 connector is properly sealed with a compatible boot or weather-proof conduit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Polarity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal electronics are isolated from the case to prevent ground loops.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-19 citation-end-19\"\u003eDuring installation, observe that Pin A goes positive relative to Pin B when the velocity move is from the base toward the top of the transducer.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324315499,"sku":"190501-01-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/190501-01-00-cnsame-day-delivery-3dmv2eklykl_b011bd7b-c289-4ace-a4f1-b20abb59b161.jpg?v=1765521260"},{"product_id":"bently-nevada-330101-33-53-10-12-cn-3300-xl-8-mm-probe","title":"Bently Nevada 330101-33-53-10-12-CN 3300 XL 8 mm Probe","description":"\u003ch3\u003eBuilt for Precision Shaft Measurement in Industrial Machinery\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330101-33-53-10-12-CN \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a non-armored 3300 XL 8 mm proximity probe developed by Bently Nevada for continuous vibration and shaft position monitoring in rotating equipment. This configuration uses a 3\/8-24 UNF threaded stainless steel body combined with a FluidLoc cable design, which improves sealing reliability in oil-rich environments such as turbine bearing housings and compressor casings.\u003c\/p\u003e\n\u003cp\u003eEngineers typically deploy this probe in machine protection systems where stable displacement signals support early detection of mechanical faults. The non-armored construction provides greater flexibility during installation, especially in tight cable routing spaces inside control cabinets and machinery skids. In refinery, power generation, and gas compression facilities, this probe plays a direct role in maintaining equipment availability and preventing unplanned shutdown events.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eHow This Model Is Physically Configured\u003c\/h3\u003e\n\u003cp\u003eThe 330101 series defines the mechanical form factor of the probe. Each suffix segment determines installation geometry, cable construction, and compliance requirements. Matching these parameters precisely is essential when replacing probes during maintenance outages.\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eConfiguration Segment\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330101\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003eUnthreaded Length: 3.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003eProbe Body Length: 5.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eTotal Cable Length: 1.0 metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approval configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure allows maintenance teams to identify the exact probe geometry without referencing mechanical drawings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMaterial and Construction Profile\u003c\/h3\u003e\n\u003cp\u003eThis probe is designed for long-term reliability in industrial environments where oil exposure, vibration, and temperature cycling are routine operating conditions.\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case\u003c\/td\u003e\n\u003ctd\u003eStainless steel AISI 303 or 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Contacts\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass or beryllium copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFluidLoc sealed industrial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Specification\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003eapprox. 2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperating Characteristics Engineers Care About\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eEngineering Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Function\u003c\/td\u003e\n\u003ctd\u003eShaft vibration and position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Style\u003c\/td\u003e\n\u003ctd\u003eThreaded mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Protection\u003c\/td\u003e\n\u003ctd\u003eNon-armored flexible cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Operating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL and 3500 monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eEddy current displacement signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTypical Questions from Maintenance and Reliability Teams\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this probe be used as a direct replacement for armored versions?\u003c\/strong\u003e\u003cbr\u003eYes, if the installation environment does not require mechanical cable protection. The sensing performance remains identical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the FluidLoc cable design?\u003c\/strong\u003e\u003cbr\u003eFluidLoc construction improves resistance to oil ingress and chemical contamination, which helps maintain signal stability inside lubricated bearing housings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe compatible with Bently Nevada 3500 monitoring racks?\u003c\/strong\u003e\u003cbr\u003eYes. It operates with standard 3300 XL extension cables and Proximitor modules used in 3500 vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the most critical parameter to match during replacement?\u003c\/strong\u003e\u003cbr\u003eMechanical length and connector configuration. Electrical compatibility is standardized across the 3300 XL 8 mm platform.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePractical Installation Notes from Field Experience\u003c\/h3\u003e\n\u003cp\u003eAvoid excessive cable tension during installation. Non-armored cables are flexible but can suffer internal conductor fatigue if stretched during routing.\u003c\/p\u003e\n\u003cp\u003eAlways verify the probe gap voltage after installation. A stable baseline signal confirms correct mechanical positioning and reliable measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eIn high-oil environments, ensure the cable entry point into the junction box is properly sealed. This simple step prevents long-term moisture or lubricant intrusion.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324348267,"sku":"330101-33-53-10-12-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-33-53-10-12-cn-t00f5l2hkss_cb7d7d36-ae92-43fc-9dbc-f30a1b958d8f.jpg?v=1765521261"},{"product_id":"330102-00-17-50-11-cn-bently-nevada-armored-3300-xl-8-mm-probe","title":"330102-00-17-50-11-CN Bently Nevada Armored 3300 XL 8 mm Probe","description":"\u003ch3\u003eWhere This Probe Is Typically Used\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330102-00-17-50-11-CN \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a field-proven 3300 XL 8 mm proximity probe designed for continuous shaft motion measurement in high-value rotating assets. Engineers commonly install this probe on steam turbines, centrifugal compressors, and large industrial pumps where vibration data directly drives protection logic.\u003c\/p\u003e\n\u003cp\u003eIn most plants, this probe operates as the front-end sensing element of a vibration protection channel. It converts shaft displacement into a stable electrical signal that the monitoring rack uses to trigger alarms or shutdowns. When installed correctly, the probe helps maintenance teams detect imbalance, misalignment, or bearing wear long before mechanical failure occurs.\u003c\/p\u003e\n\u003cp\u003eThe armored cable design is particularly valuable in environments where oil contamination, mechanical vibration, and cable abrasion are unavoidable.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMechanical Identity of Model 330102\u003c\/h3\u003e\n\u003cp\u003eThis base model is not a generic sensor. It is a specific mechanical configuration defined by Bently Nevada engineering standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e330102 represents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e3300 XL series probe platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e8 mm sensing diameter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3\/8-24 UNF mounting thread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated armored cable construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial turbine-class vibration measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis definition remains consistent across all suffix variations. The suffix only changes physical length and connection details.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Details for 330102-00-17-50-11-CN\u003c\/h3\u003e\n\u003cp\u003eEach segment of the model number defines installation geometry. Maintenance teams rely on this structure when ordering replacements during outages.\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"\"\u003eEngineering Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330102\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm armored probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded section\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003eProbe body length 170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eCable length 5.0 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eRegional configuration designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMatching these dimensions exactly is critical for maintaining calibration and mechanical fit.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCore Hardware Characteristics\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eEngineering Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored industrial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Body Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel AISI 303 or 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Material\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass or beryllium copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003eapprox. 2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Operating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Function\u003c\/td\u003e\n\u003ctd\u003eShaft vibration and position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eWhat Engineers Usually Verify Before Replacement\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a complete transducer system?\u003c\/strong\u003e\u003cbr\u003eNo. This model is the probe only. A working measurement channel requires a matched extension cable and Proximitor module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this probe replace other 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes, if the mechanical length and cable configuration are identical. The monitoring system does not need modification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the most common installation mistake?\u003c\/strong\u003e\u003cbr\u003eOrdering the wrong cable length. A mismatch will not affect electronics but will prevent physical installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes armored cable change measurement accuracy?\u003c\/strong\u003e\u003cbr\u003eNo. It improves mechanical durability and service life, especially in high-vibration turbine environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Notes from Turbine Sites\u003c\/h3\u003e\n\u003cp\u003eAlways confirm probe insertion depth before tightening the mounting nut. Excessive compression can shift the sensing position and introduce measurement drift.\u003c\/p\u003e\n\u003cp\u003eKeep the probe cable separated from motor power lines and variable frequency drive wiring. Electrical noise is one of the most common causes of unstable vibration signals.\u003c\/p\u003e\n\u003cp\u003eIf the machine operates above 120 deg C ambient temperature, verify that the cable routing path avoids direct radiant heat from turbine casings.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324381035,"sku":"330102-00-17-50-11-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330102-00-17-50-11-cn-achxjvhkapk_711d7d3b-3678-4fe4-a104-55a34dbc4606.jpg?v=1765521262"},{"product_id":"330101-00-34-10-02-cn-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330101-00-34-10-02-CN Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003ePRODUCT OVERVIEW\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330101-00-34-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance eddy current sensor from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 XL series\u003c\/strong\u003e. This 8 mm proximity probe is engineered for non-contacting displacement measurements, specifically monitoring shaft vibration and axial position in critical rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThis model features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3\/8-24 UNF thread\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand is supplied\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewithout armor\u003c\/strong\u003e, making it ideal for installations where the cable is routed through dedicated protective conduits or internal machine galleries. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCN approval\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures compliance with specific regional safety and hazardous area standards for the Chinese market.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePART NUMBER CONFIGURATION\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 inches (Fully threaded body)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-34\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.4 inches (Standard threaded reach)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 metre (3.3 feet) integrated lead\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc™ connector (Standard cable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCountry-specific approvals (China)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTECHNICAL DATA SHEET\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Principle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEddy Current (Inductive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.0 mm (80 mils)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScale Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.87 V\/mm (200 mV\/mil) ±5%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAISI 4140 Steel (Standard Calibration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-51 °C to +177 °C (-60 °F to +350 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTip Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePolyphenylene sulfide (PPS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCase Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAISI 303 or 304 Stainless Steel (SST)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFIELD ENGINEERING INSTALLATION GUIDE\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Mounting and Gapping\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThread the probe into the mounting bracket or machine casing. To set the gap accurately, use a digital voltmeter to monitor the DC output of the Proximitor® sensor. Adjust the probe position until the voltage reads\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-9.0 VDC\u003c\/strong\u003e, which corresponds to the midpoint of the 80-mil linear range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Securing the Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOnce the gap is set, tighten the locknut to the recommended torque of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4.5 N·m (40 in-lb)\u003c\/strong\u003e. Re-check the gap voltage after tightening; if the voltage has shifted significantly, loosen the nut and re-adjust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Connector Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClickLoc™ connector\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires a firm push to engage. You should hear\/feel a \"click\" indicating a secure electrical connection. Since this is the \"without armor\" version, ensure the coaxial cable is supported and not subjected to sharp edges or high-tension pulling during routing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. System Length Consistency\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis probe has a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.0m total length\u003c\/strong\u003e. To ensure the system remains within calibration, it must be used with a 4.0m or 8.0m extension cable to achieve a total system length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0m or 9.0m\u003c\/strong\u003e, matching the Proximitor® sensor's requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eLOGISTICS DATA\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMade in U.S.A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.323 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNEPSI\/CCC (CN Option) for hazardous area use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324413803,"sku":"330101-00-34-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-34-10-02-cn-qkwu2jyjv1l_58cb7b4a-6428-4f89-a2c1-8ed199ac8016.jpg?v=1765521263"}],"url":"https:\/\/www.plcprotech.com\/collections\/all\/pressure-switches.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}