{"title":"Allen-Bradley CompactLogix","description":"\u003cp\u003eAllen-Bradley CompactLogix controllers offer Logix-based performance in a compact, modular footprint for mid-range applications. The architecture features rack-less 1769- or 5069- modules that snap together, or high-performance 1768- configurations for motion-heavy tasks. Technical characteristics include integrated safety (SIL3), high-density I\/O options, and dual EtherNet\/IP ports for DLR (Device Level Ring) topologies. Functionally, CompactLogix bridges the gap between small machinery and plant-wide DCS, providing a cost-effective solution for standalone machine control. When paired with \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/allen-bradley-panelview\"\u003ePanelView\u003c\/a\u003e interfaces, it delivers a powerful, integrated automation solution for water treatment, food processing, and material handling systems.\u003c\/p\u003e","products":[{"product_id":"allen-bradley-1769-ob32-compactlogix-compact-i-o-solid-state-dc-output-module","title":"Allen-Bradley 1769-OB32 CompactLogix Compact I\/O Solid-State DC Output Module","description":"\u003cp\u003eThe \u003cstrong\u003e1769-OB32\u003c\/strong\u003e is a high-density 32-point discrete solid-state electronic module designed to provide sourcing direct-current switching capabilities within the \u003cstrong\u003eCompactLogix \/ Compact I\/O\u003c\/strong\u003e hardware infrastructure. It converts electronic control logic commands from a central processor into discrete 24 VDC output paths divided into two separate, isolated groups of 16 channels each. This hardware allows low-power programmatic actuation of direct-current devices including industrial control relays, indicators, display panels, and small solenoid valves. The assembly interfaces natively with \u003cstrong\u003eCompactLogix\u003c\/strong\u003e automation systems or functions as distributed field hardware through a \u003cstrong\u003eMicroLogix\u003c\/strong\u003e controller expansion link or network adapter module. System interlocking is maintained through an optoelectronic safety barrier providing a continuous 30 VDC working isolation voltage profile to protect internal system backplane components against plant field line anomalies.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Channel Array\u003c\/strong\u003e: Packs 32 discrete solid-state source-type outputs inside a single-slot module footprint to save panel space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Group Isolation\u003c\/strong\u003e: Separates channels into two distinct electrical banks of 16 outputs, permitting independent field power supply routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Short-Circuit Protection\u003c\/strong\u003e: Incorporates an integrated electronic protection matrix that auto-detects thermal\/current faults to minimize down-time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Slot Keying\u003c\/strong\u003e: Features integrated mechanical tongue-and-groove guide rails to prevent incorrect alignment during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Diagnostic LED Panel\u003c\/strong\u003e: Provides 32 separate green indicators to deliver real-time channel state visualization for point-level testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable Terminal Block\u003c\/strong\u003e: Employs a 40-pin finger-safe terminal block with a latching door mechanism to enable hot-swapping sequences without wire removal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDriving localized low-power direct current pneumatic solenoid manifolds.\u003c\/li\u003e\n\u003cli\u003eInterfacing control logic to discrete input channels of motor speed controllers.\u003c\/li\u003e\n\u003cli\u003eMain operator desk visual illumination lamps and pilot sounders.\u003c\/li\u003e\n\u003cli\u003eActuating discrete interface auxiliary relays in process manufacturing lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1769-OB32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompactLogix \/ Compact I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-state 24V DC Source Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs Per Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 sourcing outputs (2 groups of 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 VDC to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum On-State Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point @ 60 Celsius \/ 1.0 A per point @ 30 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Per Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 A @ 60 Celsius \/ 8.0 A @ 30 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Module Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 A @ 60 Celsius \/ 16.0 A @ 30 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA @ 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Off-State Leakage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mA @ 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum On-State Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 VDC @ 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Turn-On Time Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Turn-Off Time Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking Isolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 VDC continuous, basic insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Boundary Mapping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup-to-group and group-to-system backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Type Test Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTested @ 710 VDC for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Distance Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 modules maximum from system power supply module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Relative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Hardware Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail installation or Panel Mount with screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Width Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVDC 1 (+)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Power Supply Input Reference for Group 1 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOUT 0 to OUT 15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSourcing Output Channel 0 through Channel 15 (Group 1 Matrix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM 1 (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Current Common Ground Return for Group 1 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVDC 2 (+)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Power Supply Input Reference for Group 2 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOUT 16 to OUT 31\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSourcing Output Channel 16 through Channel 31 (Group 2 Matrix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM 2 (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Current Common Ground Return for Group 2 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Connection Latching\u003c\/strong\u003e: Align the side tongue-and-groove tracks precisely before mating the expansion connector. Slide the integrated mechanical bus lever completely to the left position to lock the backplane connectors firmly into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Proximity Matching\u003c\/strong\u003e: Do not exceed the strict 8-slot distance limitation boundary when placing the hardware module relative to the nearest system power supply block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring Entry Limits\u003c\/strong\u003e: Connect only copper wire configurations rated for 75 degC minimum. Single wire gauges must fall inside the 0.32 to 0.82 mm2 (22 to 18 AWG) window with insulation stripping adjusted to 11 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection Practices\u003c\/strong\u003e: Ground the hosting DIN rail or backplane framework back to an earth anchor point using heavy gauge wire to mitigate transient radio-frequency or electromagnetic fields.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDetailed Installation Reference\u003c\/h3\u003e\n\u003cp\u003eFor comprehensive step-by-step physical mounting, wiring arm configurations, and detailed channel layout diagrams, please refer to the official installation publication:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1769-in031_-en-p.pdf?v=1780145237\"\u003e👉 \u003cstrong\u003eClick Here to Download the Full Allen-Bradley 1769-OB32 Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this specific model function as a sourcing type or a sinking type output card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This module functions exclusively as a sourcing type device, meaning it switches the positive voltage potential (+VDC) from the supply line out to the field load terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can Group 1 and Group 2 be powered by completely separate power supplies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, because Group 1 and Group 2 are completely isolated from each other, you can use two distinct 24V DC power sources landed on their respective VDC and COM terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum current load allowed on a single channel point when operating at full 60 Celsius temperature specs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: When running at an ambient temperature of 60 Celsius, the maximum continuous output current limit is 0.5 A per individual channel point.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695185555819,"sku":"1769-OB32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1769-ob32-machine-control-kiqifbfu0pa_a1b1c9eb-6f18-40e5-a34e-8d5eaf9d14ef.jpg?v=1766114446"},{"product_id":"allen-bradley-1769-if4xof2-compactlogix-analog-combination-module","title":"Allen-Bradley 1769-IF4XOF2 CompactLogix Analog Combination Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-IF4XOF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile analog I\/O combination module designed for the Allen-Bradley CompactLogix platform. By integrating both inputs and outputs into a single-slot width, this module provides a space-efficient solution for applications requiring a mix of analog signals, such as temperature control, pressure monitoring, and valve positioning.\u003c\/p\u003e\n\u003cp\u003eThe module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour analog inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(configurable as single-ended or differential) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo analog outputs\u003c\/strong\u003e. This hybrid design is particularly beneficial for smaller automation systems where cabinet space is limited, as it eliminates the need for separate input and output modules. With support for both voltage and current signals, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-IF4XOF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers the flexibility needed to interface with a wide variety of industrial sensors and actuators.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1769-IF4XOF2 is engineered for high reliability and ease of installation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Input Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4 inputs can be wired as single-ended for maximum density or differential to provide better noise immunity in electrically \"noisy\" environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Signal Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with standard industrial signals, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–20 mA, 4–20 mA, 0–10V DC, and ±10V DC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA front-facing green \"OK\" LED provides immediate visual confirmation of module health and backplane communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes built-in DIN rail latches and panel mounting tabs, allowing for secure installation in various enclosure types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDraws a modest 120 mA at 5V DC and 160 mA at 24V DC from the backplane, helping to stay within the power budget of the CompactLogix power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1769-IF4XOF2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Combination (Input\/Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (Single-ended or Differential)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 (Single-ended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10V, 0-10V, 0-5V, 1-5V, 0-20mA, 4-20mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10V, 0-10V, 0-5V, 1-5V, 0-20mA, 4-20mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Distance Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e118 x 35 x 87 mm (approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.43 kg (0.94 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix voltage and current signals on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each channel on the 1769-IF4XOF2 is individually configurable in the programming software (Studio 5000 or RSLogix 5000). You can have a pressure sensor using 4-20 mA on Channel 0 and a potentiometer using 0-10V on Channel 1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Power Supply Distance Rating\" of 8?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis rating indicates that the module must be located within 8 slots of a 1769 power supply. Placing it further away can result in insufficient voltage levels due to bus resistance, leading to intermittent communication or inaccurate analog readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of using Differential inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDifferential wiring uses two signal leads (plus a shield) and is highly effective at rejecting \"common-mode noise.\" If your sensor cables run near high-voltage motor wires or VFDs, differential wiring is the best way to ensure a stable, jitter-free signal.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Signal Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo ensure the highest accuracy, always use shielded twisted-pair cables for analog signals. Connect the shield to a single ground point (typically at the PLC chassis) to prevent ground loops. Avoid routing these low-voltage signal cables in the same conduit as high-power AC lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModule Placement and Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen calculating your system's power budget, remember that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-IF4XOF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edraws current from both the 5V and 24V DC buses. Ensure your 1769-PA2, PB2, or PA4 power supply has sufficient capacity to support this module along with any others in the bank.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn your controller's I\/O configuration tree:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAdd the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-IF4XOF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the appropriate slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigure the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInput Filter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., 60 Hz) to match your local power frequency to help reject electrical hum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSet the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eReal-Time Sampling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterval to balance the need for fast data with CPU overhead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDefine the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eScaling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., 4-20 mA = 0-100 psi) within the module tags for easier programming.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695190864235,"sku":"1769-IF4XOF2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1769-if4xof2-analog-i-o-module-3nquvodlung_e756514b-b266-420e-974c-b0084a3306cd.jpg?v=1766114624"},{"product_id":"1768-pa3-allen-bradley-compactlogix-120-240v-ac-power-supply","title":"1768-PA3 Allen-Bradley CompactLogix 120\/240V AC Power Supply","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview and System Power Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3 (1768PA3)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency AC input power supply specifically designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-L43 and 1768-L45 CompactLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrollers. As part of the 1768-series architecture, this module provides the essential regulated DC voltages required to power the controller, the 1768 backplane, and any attached 1768 communication modules (such as the 1768-ENBT or 1768-CNB). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to handle the higher power demands of the 1768-series, which supports integrated motion and high-performance networking, making it a critical foundation for mid-range automation systems in conveyor control, assembly lines, and specialized process skids.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Architecture and Electrical Logic\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emounts directly to the left side of the 1768 controller. It converts standard industrial AC line power into the precise DC rails needed for internal logic and communication circuitry.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal AC Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports a wide input range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e85–265V AC\u003c\/strong\u003e, allowing for global deployment in both 110V and 220V power systems without the need for external transformers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed to provide sufficient current for up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo 1768-series communication or motion modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealongside the main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegulated Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a stabilized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5V DC and 24V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebackplane output, ensuring that voltage fluctuations on the factory floor do not affect the deterministic performance of the PLC logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Status Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a front-panel \"DC OK\" LED that provides immediate visual confirmation that the supply is outputting the correct voltages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley \/ Rockwell Automation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120V AC \/ 240V AC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47–63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Power (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32.5 W @ 5V DC; 28 W @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Power Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e60.5 W\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 A (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1.2 kg\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eIntegrated Technical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1768-PA3 with 1769-L3x controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis physically and electrically designed only for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-L43 and 1768-L45\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrollers. 1769-series controllers use 1769-PA2 or PA4 power supplies, which have a different form factor and backplane connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes the \"DC OK\" LED to turn off?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlit LED typically indicates one of three things: a loss of AC input power, an internal fuse failure, or an over-current condition on the backplane (often caused by a faulted communication module). Always measure the input terminals first to confirm line power is present.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide power for the field I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epowers the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtroller and the 1768-series modules only\u003c\/strong\u003e. If you have 1769-series I\/O modules attached to the right side of the controller, those I\/O modules may require their own 1769-series power supply (like a 1769-PA2) depending on the total current draw.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Protocols\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse a minimum of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e14 AWG (2.1 mm²)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewire for AC input connections. Ensure the \"Ground\" terminal is connected to a clean, low-impedance earth ground to help filter out electrical noise and protect against surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edissipates heat through convection. Maintain a minimum of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2 in.)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance above and below the module. If the module is installed in a small, unventilated enclosure, the internal thermal protection may trip, causing the PLC to shut down.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFinger-Safe Terminals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe terminal block features a protective cover. Always keep this cover closed during operation to prevent accidental contact with high-voltage AC terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1768-PA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust power-to-footprint ratio\u003c\/strong\u003e. It is built to support the high-speed data processing and motion synchronization required by the 1768-L4x series, which was a pioneer in bringing high-end Logix performance to a compact form factor. Its ability to bridge the gap between heavy-duty industrial power and sensitive micro-electronics makes it a reliable choice for \"Workhorse\" applications in the packaging and material handling industries where power quality may be inconsistent.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695191617899,"sku":"1768-PA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1768-pa3-compactlogix-power-supplies-v4fofautowh_273d2c06-390c-4de3-ae56-5d41e0de6646.jpg?v=1766114652"},{"product_id":"allen-bradley-5069-l306erm-compactlogix-5380-controller","title":"Allen-Bradley 5069-L306ERM CompactLogix 5380 Controller","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, mid-range controller from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily by Rockwell Automation. Designed for modern industrial applications, it provides increased processing power, high-speed I\/O throughput, and integrated motion control capabilities. It is particularly well-suited for machine builders requiring precision, scalability, and enhanced security within the Logix 5000 ecosystem.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L306ERM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Motion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2 CIP Motion axes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 16 Ethernet\/IP nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 8 local 5069 I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModule requires external 5069-RTB22 or similar for DC power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming Software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functionalities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Integrated Motion on EtherNet\/IP\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \"M\" in the model name signifies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntegrated Motion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapability. The 5069-L306ERM supports up to 2 axes of coordinated motion, allowing for precise control of Kinetix drives and motors over a standard Ethernet cable without the need for dedicated motion hardware.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Dual Gigabit Ethernet Ports\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis controller features two 1-Gigabit Ethernet ports that can be configured in two modes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAssign separate IP addresses to each port to isolate plant-floor traffic from the enterprise network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear\/DLR Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows for Device Level Ring (DLR) topologies, providing network resiliency so that a single cable break does not stop the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e3. 5069 I\/O Platform\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIt utilizes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069 Compact I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform, which offers significantly faster backplane speeds compared to older generations. This results in reduced latency and more deterministic I\/O performance for high-speed counting or sensing applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 5069-L306ER and the 5069-L306ERM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion is a standard controller with no integrated motion capability. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion includes support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCIP Motion\u003c\/strong\u003e, making it capable of controlling synchronized servo axes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 5069-L306ERM require a battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Like most modern Logix controllers, it uses internal non-volatile memory and energy storage (capacitors) to back up the user program and data during a power loss, eliminating the need for periodic battery replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use 1769-series I\/O modules with this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 5380 series is only compatible with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform for local modules. To use 1769 modules, you would need to connect to them as remote I\/O via an Ethernet adapter (e.g., 1769-AENTR).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller requires two separate DC power inputs:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for the controller and module electronics) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for field-side power to the I\/O). These must be connected via a removable terminal block (RTB).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity Features:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5069-L306ERM includes controller-based security features, such as digitally signed firmware and role-based access control, to help protect against unauthorized modifications and cyber threats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed for standard DIN rail mounting. Ensure adequate clearance (approx. 50mm) above and below the module to allow for passive convection cooling, as this series can run warm during high-load processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLow-Latency Performance\u003c\/strong\u003e. With a Gigabit backplane and high-speed task execution, it can handle complex logic and motion tasks with minimal jitter. It serves as an ideal entry-point for motion applications that don't require the massive memory or high axis count of the 1756 ControlLogix line, but still demand the reliability and precision of the Allen-Bradley brand.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53083968635243,"sku":"5069-L306ERM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L306ERM_2.png?v=1775992178"},{"product_id":"allen-bradley-5069-l310erm-compactlogix-5380-controller","title":"Allen-Bradley 5069-L310ERM CompactLogix 5380 Controller","description":"\u003cp\u003e\u003cspan class=\"citation-382\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e5069-L310ERM\u003c\/strong\u003e\u003cspan class=\"citation-382\"\u003e is a high-performance, mid-range controller within the \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan class=\"citation-382 citation-end-382\"\u003e family.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e It is designed to meet the high-speed processing and data-intensive requirements of modern \"smart\" machines. This controller is a significant step up from the entry-level L306 model, offering expanded memory and node capacity while maintaining the same compact form factor.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Motion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to \u003cstrong\u003e4 axes\u003c\/strong\u003e (CIP Motion over EtherNet\/IP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to \u003cstrong\u003e24 nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 local 5069 Compact I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB 2.0 (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNon-volatile Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 GB (via 1784-SD2 card)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Scalable Motion Control\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \"M\" designation confirms this controller is motion-capable. \u003cspan class=\"citation-381\"\u003eIt supports up to \u003c\/span\u003e\u003cstrong\u003e4 axes of coordinated CIP Motion\u003c\/strong\u003e\u003cspan class=\"citation-381 citation-end-381\"\u003e, allowing for precise control of servo drives (like the Kinetix 5500 or 5700) over a standard Ethernet network.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-380 citation-end-380\"\u003eIt can also manage up to 256 non-integrated motion axes.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Advanced Gigabit Networking\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan class=\"citation-379 citation-end-379\"\u003eEquipped with dual 1-Gbps Ethernet ports, the 5069-L310ERM supports high-speed data exchange and flexible network topologies:\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e Allows the controller to have two different IP addresses—one for the machine-level I\/O network and one for the plant-level enterprise network—improving security and traffic isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear\/DLR Mode:\u003c\/strong\u003e\u003cspan class=\"citation-378 citation-end-378\"\u003e Supports Device Level Ring (DLR) for high network availability; if one cable in the ring breaks, the system continues to communicate without interruption.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Enhanced System Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePart of the 5380 series, this controller features a high-speed backplane that significantly reduces I\/O scan times compared to the older 1769 CompactLogix series. This makes it an excellent choice for applications requiring rapid safety reaction times or high-speed registration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 5069-L310ERM compare to the 5069-L306ERM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-377\"\u003eThe \u003c\/span\u003e\u003cstrong\u003eL310ERM\u003c\/strong\u003e\u003cspan class=\"citation-377\"\u003e offers nearly double the user memory (\u003c\/span\u003e\u003cstrong\u003e1 MB\u003c\/strong\u003e\u003cspan class=\"citation-377\"\u003e vs 0.6 MB), supports more Ethernet nodes (\u003c\/span\u003e\u003cstrong\u003e24\u003c\/strong\u003e\u003cspan class=\"citation-377\"\u003e vs 16), and doubles the number of supported CIP motion axes (\u003c\/span\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003cspan class=\"citation-377 citation-end-377\"\u003e vs 2).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power is required for this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt requires a dual-feed DC power supply:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-376\"\u003e\u003c\/span\u003e\u003cstrong\u003eMOD Power (18-32V DC):\u003c\/strong\u003e\u003cspan class=\"citation-376 citation-end-376\"\u003e Powers the controller's internal logic.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-375\"\u003e\u003c\/span\u003e\u003cstrong\u003eSA Power (18-32V DC):\u003c\/strong\u003e\u003cspan class=\"citation-375 citation-end-375\"\u003e Provides power for the field-side circuitry of the connected I\/O modules.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require a battery for program backup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 5069-L310ERM uses an internal energy storage module (capacitors) to write the program to non-volatile memory during a power loss, eliminating the need for lithium batteries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Horizontal mounting on a standard 35 mm DIN rail is required. Ensure at least 50 mm (2 in.) of clearance above and below the unit for convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Placement:\u003c\/strong\u003e The controller must be the leftmost module in a local 5069 I\/O bank.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemovable Terminal Blocks (RTB):\u003c\/strong\u003e Ensure you have the required RTB (typically 5069-RTB18 or 5069-RTB14) to connect the MOD and SA power feeds, as these are often sold separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e5069-L310ERM\u003c\/strong\u003e is ideal for applications that have outgrown the memory constraints of entry-level controllers but do not yet require the high axis counts of the L320 or L330 models. Its Gigabit Ethernet performance ensures that the controller can handle the increased traffic of modern IIoT (Industrial Internet of Things) devices and high-resolution HMI screens without compromising logic execution speed.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53083969159531,"sku":"5069-L310ERM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Allen-Bradley5069-L310ERM.png?v=1775992904"},{"product_id":"allen-bradley-5069-l310er-nse-compactlogix-5380-no-stored-energy-controller","title":"Allen-Bradley 5069-L310ER-NSE CompactLogix 5380 No-Stored-Energy Controller","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized version of the CompactLogix 5380 controller designed for environments where \"stored energy\" is a safety or security risk. While it retains the core high-performance characteristics of the 5380 series, it is specifically engineered for hazardous or restricted areas—such as mining, explosives manufacturing, or highly secure data centers—where traditional energy-storing capacitors are prohibited.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNSE Feature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNo Stored Energy\u003c\/strong\u003e (No internal capacitors\/batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 24 Ethernet\/IP nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 local 5069 Compact I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming Software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. No Stored Energy (NSE) Technology\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eStandard CompactLogix controllers use internal energy storage modules (capacitors) to write data to non-volatile memory during a power loss. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNSE version\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eremoves these components. This ensures that when power is cut, the energy dissipated is below the threshold required to trigger an ignition in explosive atmospheres, meeting strict\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous Area\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntrinsically Safe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Dual Gigabit Ethernet \u0026amp; High-Speed Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eDespite its specialized safety features, it maintains the performance of the 5380 series:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGigabit Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual 1-Gbps ports support high-speed data exchange.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows for network segmentation, isolating machine-level I\/O traffic from higher-level enterprise networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDLR Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports Device Level Ring for high network availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e3. High-Speed 5069 Backplane\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIt utilizes the 5069 Compact I\/O platform, which provides much faster scan times and higher accuracy for time-critical applications compared to the older 1769 series.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the NSE version handle data during power loss?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elacks the internal energy to write data to the SD card during an unexpected power down, any data not already saved to the non-volatile memory (or synchronized to a SCADA\/DB system) will be lost. In these applications, engineers typically use an external Uninterruptible Power Supply (UPS) if data retention is critical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this for motion control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edoes not have the \"M\" designation. If you require integrated motion in a no-stored-energy format, you would need to look for an \"ERM-NSE\" variant, though the L310ER-NSE is primarily used for discrete and process logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"SA Power\" and \"MOD Power\" on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5069 architecture separates the power feeds:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers the internal controller logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers the field-side circuitry of the I\/O modules. Both must be wired via a removable terminal block (RTB).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Dependency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSince this unit cannot back itself up, ensure your application logic is designed for \"clean\" restarts. Use the 1784-SD2 card to store the project, but be aware that tag values will revert to their last saved state upon power cycling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard horizontal DIN rail mounting. Like other 5380 controllers, it requires adequate spacing for thermal dissipation as the high-speed processor generates significant heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NSE series is frequently mandated in secure government or military facilities where the ability of a device to hold a charge (and thus potentially maintain data in memory) after power removal is viewed as a security vulnerability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the industry standard for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous Location Safety\u003c\/strong\u003e. It allows plant managers to deploy a high-speed, modern Logix controller into zones where they previously had to rely on older, less capable technology. By eliminating stored energy, Rockwell has provided a path to modernize explosives handling, chemical processing, and underground mining operations without compromising safety protocols.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53083971518827,"sku":"5069-L310ER-NSE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L310ER-NSE.png?v=1775993302"},{"product_id":"allen-bradley-5069-rtb18-screw-removable-terminal-block","title":"Allen-Bradley 5069-RTB18-SCREW Removable Terminal Block","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 18-pin removable terminal block (RTB) designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It serves as the physical interface between the field-side wiring and the I\/O modules or controllers. The \"SCREW\" designation indicates that this model utilizes traditional screw-clamp terminations, providing a high-torque, secure connection for industrial environments where vibration resistance and wiring reliability are paramount.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Pins\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTorque Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 N·m (3.5 lb·in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size (Solid)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22–12 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size (Stranded)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22–14 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A per pin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functionalities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. High-Density Connectivity\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 18-pin layout is designed to match the high-density architecture of the 5069 I\/O series. It allows for the termination of multiple signal and return wires on a single block, maximizing cabinet space.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Removable Architecture (RIUP)\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eA key feature of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis its support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e. This allows maintenance personnel to replace a faulty I\/O module without disconnecting the field wiring, significantly reducing Mean Time to Repair (MTTR) and preventing wiring errors during hardware swaps.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Secure Screw Termination\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eUnlike the \"SPRING\" (push-in) variants, the screw-clamp mechanism ensures a gas-tight connection that is highly resistant to mechanical loosening. This makes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethe preferred choice for applications in heavy manufacturing, mining, and oil \u0026amp; gas where equipment is subject to constant physical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 5069-RTB18-SCREW compatible with all 5069 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is compatible with many 5069 discrete and analog modules, but you must verify the pin count. Some specialized modules require 14-pin blocks (\u003cstrong\u003e5069-RTB14\u003c\/strong\u003e). Always check the specific I\/O module's technical data sheet to ensure 18 pins are supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix screw and spring terminal blocks in the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The choice of RTB is module-specific. You can use a screw-type RTB for an analog input module and a spring-type RTB for a discrete output module within the same\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a special tool for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA standard small flat-head screwdriver (typically 3.5 mm) is required to tighten the clamps to the recommended torque of 0.4 N·m.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOver-tightening can damage the internal clamp, while under-tightening can lead to intermittent signals or arcing. Using a calibrated torque screwdriver is recommended for safety-critical circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Preparation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStrip the wire insulation back approximately 10–12 mm. For stranded wire, the use of ferrules is highly recommended to prevent fraying and ensure a clean insertion into the clamp.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeying:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5069 series supports mechanical keying. It is best practice to use the keying tabs to prevent an RTB wired for high voltage from being accidentally inserted into a low-voltage analog module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis favored for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRobustness and Versatility\u003c\/strong\u003e. In global industrial markets, screw terminals are often mandated by local electrical standards for their visibility—an engineer can visually verify that a screw is tightened, providing an extra layer of confidence during commissioning. By isolating the wiring from the electronic module, Rockwell has created a modular system that simplifies both the initial build and long-term maintenance of the control cabinet.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084005564779,"sku":"5069-RTB18-SCREW","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Allen-Bradley5069-RTB18-SCREW.png?v=1775993709"},{"product_id":"allen-bradley-5069-l310erms2-compact-guardlogix-5380-sil-2-controller","title":"Allen-Bradley 5069-L310ERMS2 Compact GuardLogix 5380 SIL 2 Controller","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ERMS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance safety controller from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact GuardLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It provides integrated control for both standard and safety-related industrial applications, achieving safety ratings up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2 \/ PLd (Category 3)\u003c\/strong\u003e. This controller is designed for machine builders who require a single, compact unit to manage complex logic, high-speed I\/O, and motion, while simultaneously ensuring functional safety for personnel and equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L310ERMS2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIL 2 \/ PLd (Category 3)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Motion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to \u003cstrong\u003e4 axes\u003c\/strong\u003e (CIP Motion over EtherNet\/IP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to \u003cstrong\u003e24 nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 local 5069 modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v31 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Integrated Safety \u0026amp; Standard Control\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ERMS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the need for a separate safety PLC. It uses a \"1oo2\" (one out of two) internal architecture to monitor and execute safety functions. In Studio 5000, safety logic is kept in a dedicated \"Safety Task\" with restricted access, ensuring that standard code modifications do not inadvertently affect safety signatures.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Integrated Motion on EtherNet\/IP\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \"M\" in the catalog number signifies integrated motion support. It can coordinate up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 axes of CIP Motion\u003c\/strong\u003e, allowing for synchronized control of Kinetix servo drives. Crucially, this includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCIP Safety over EtherNet\/IP\u003c\/strong\u003e, enabling safe speed, safe direction, and safe torque off (STO) functions to be managed over the same network cable as the standard control data.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. High-Speed Performance \u0026amp; Dual Gigabit Ethernet\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows for the physical separation of safety\/I\/O traffic from the higher-level enterprise network, which is vital for maintaining safety determinism and cybersecurity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDLR Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports Device Level Ring topologies to ensure that a single cable failure does not drop the safety connection, preventing nuisance trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 5069-L310ERM and the 5069-L310ERMS2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL310ERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a standard controller with motion support. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL310ERMS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadds a dedicated 0.5 MB safety memory partition and the internal diagnostics required to be certified for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use standard 5069 I\/O modules with this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can mix standard 5069 I\/O modules for non-safety tasks and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB8S \/ OBV8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety modules for safety tasks in the same local rack or on the same remote EtherNet\/IP network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller require a safety partner module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Unlike the older 1756 GuardLogix systems that required a primary and a safety partner, the Compact GuardLogix 5380 series (like the L310ERMS2) is a self-contained safety controller.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Signatures:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnce the safety logic is validated, the controller generates a unique safety signature. Any change to the safety code changes this signature, providing a clear audit trail for regulatory compliance (e.g., OSHA or CE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLike other 5069 units, it requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for logic) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for field-side I\/O power). Use high-quality DC power supplies to ensure the safety bus remains stable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller is designed for an operating temperature range of 0 to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e60°C\u003c\/span\u003e. In safety applications, ensure that cabinet cooling is adequate, as the safety processor performs intense internal self-diagnostics that generate additional heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084049211755,"sku":"5069-L310ERMS2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L310ERMS2_2.png?v=1775994732"},{"product_id":"allen-bradley-5069-ib16-compact-5000-digital-input-module","title":"Allen-Bradley 5069-IB16 Compact 5000 Digital Input Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital DC input module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley Compact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It is designed to interface with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix 5580\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(via remote EtherNet\/IP) controllers. Featuring 16 sinking inputs, this module is optimized for high-speed industrial applications where fast response times and precise signal detection are critical for machine performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Sinking)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12\/24V DC Sink\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10V DC (Min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mA (Min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ms to 30000 ms (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power (MOD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA @ 18–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor\/Actuator Power (SA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA @ 18–32V DC (plus field load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. High-Speed Processing\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eAs part of the Compact 5000 I\/O platform, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides significantly faster I\/O-to-backplane communication speeds compared to older 1769 or 1734 platforms. This ensures that the controller receives input state changes with minimal latency, improving the accuracy of high-speed sensors and registration marks.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Sinking Input Design\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe module uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSinking\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture, meaning it provides a path to the negative common for the connected device. This is the standard interface for \"Sourcing\" (PNP) field sensors.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Extensive Diagnostics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 5069-IB16 features advanced diagnostic capabilities. Through Studio 5000, engineers can monitor:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Health:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStatus of the backplane connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power Status:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetection of whether field-side power is present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput State LEDs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual green status indicators for each of the 16 channels, located on the front of the module for immediate physical troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Removable Terminal Block (RTB) does this module use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5069-IB16 is compatible with the 18-pin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(screw-clamp) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(push-in style) terminal blocks. Note that RTBs are typically sold separately from the I\/O module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support RIUP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Like other Compact 5000 I\/O modules, it supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e, allowing you to replace the module without shutting down the entire system or disconnecting field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"SA Power\" requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSensor\/Actuator (SA) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto be fed through the controller or the field potential distributor. This power is used to provide the voltage for the inputs and the field-side circuitry.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Practice:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded cable for inputs that are subjected to high electromagnetic interference (EMI). Ensure that the SA power common is correctly tied to the sensor common to establish a complete circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilter Settings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjust the digital filter settings in Studio 5000 to eliminate \"contact bounce\" from mechanical limit switches. For high-speed proximity sensors, set the filter time to the minimum (0 ms) to capture rapid pulses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mounting 16-point modules side-by-side, ensure the enclosure has adequate ventilation. The 5069 series utilizes passive convection cooling and requires at least 50mm of clearance above and below the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis favored for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEfficiency and Reliability\u003c\/strong\u003e. By providing 16 points in a very slim profile, it allows for high-density I\/O configurations in small control cabinets. Its deterministic performance makes it the standard choice for modern Allen-Bradley architectures where the goal is to synchronize high-speed I\/O with CIP Motion or complex safety logic.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084451799403,"sku":"5069-IB16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-IB16_2.png?v=1775995151"},{"product_id":"allen-bradley-5069-l310er-compactlogix-5380-controller","title":"Allen-Bradley 5069-L310ER CompactLogix 5380 Controller","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial controller from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It is designed to function as the \"brain\" of modern mid-sized automation systems, providing the high-speed processing and data capacity required for Industrial IoT (IIoT) applications. While it shares the same processing architecture as the motion-capable \"ERM\" models, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL310ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for discrete and process control where integrated servo motion is not required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L310ER\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to \u003cstrong\u003e24 Ethernet\/IP nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 local 5069 Compact I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB 2.0 (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-input (MOD and SA power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. High-Speed Logic Execution\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 5380 series features a dedicated high-speed backplane that significantly increases I\/O scan rates compared to the older 1769 series. With 1 MB of memory, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan handle complex logical operations, arithmetic, and data string manipulations with extremely low latency.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Advanced Networking Options\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe controller includes dual 1-Gbps Ethernet ports that offer two primary configuration modes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis allows you to separate machine-level network traffic (sensors\/drives) from the plant-wide enterprise network, enhancing security and preventing network congestion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDevice Level Ring (DLR):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn this mode, the ports provide network resiliency; if a single cable in the ring is damaged, communication continues uninterrupted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Compact 5000 I\/O Integration\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe controller acts as the master for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069 Compact I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This platform is known for its high-density design and advanced diagnostics, allowing for more I\/O points in a smaller cabinet footprint.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 5069-L310ER and 5069-L310ERM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"M\" in the ERM version stands for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMotion\u003c\/strong\u003e. The L310ERM supports up to 4 axes of Integrated CIP Motion (servo control). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL310ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis for standard applications and does not support coordinated servo motion over EtherNet\/IP.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller require a battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The CompactLogix 5380 series uses an internal energy storage module (capacitors) to back up the user program to non-volatile memory during a power failure. You do not need to replace or maintain lithium batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power terminal block do I need?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB22-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB22-SPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal block to connect the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Module) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Sensor\/Actuator) power feeds.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Partitioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure you wire both MOD power (for the CPU) and SA power (for the I\/O field side). Even if the CPU is running, your local I\/O modules will not function without a valid SA power feed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5380 series contains a high-speed processor that generates heat. Always mount the unit horizontally on a DIN rail and maintain at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2 in.)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance above and below for passive cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Updates:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways check the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProduct Compatibility and Download Center (PCDC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the latest firmware. This controller often requires a firmware flash out of the box before it can be used with your specific version of Studio 5000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the \"sweet spot\" for engineers who need more than the entry-level 0.6 MB memory but don't want to pay the premium for motion axes they won't use. Its 24-node capacity makes it ideal for integrating multiple remote I\/O racks, PowerFlex drives, and HMI panels into a single, cohesive control architecture.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084604334443,"sku":"5069-L310ER","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L310ER.png?v=1775995917"},{"product_id":"allen-bradley-5069-l320er-compactlogix-5380-controller","title":"Allen-Bradley 5069-L320ER CompactLogix 5380 Controller","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L320ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial controller within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It is designed for mid-to-large scale automation tasks that require significant memory for data-heavy applications and complex logic. While it shares the high-speed processing architecture of the \"ERM\" motion models, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL320ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for discrete and process control environments where integrated servo motion control is not required, offering a cost-effective solution for high-node-count systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L320ER\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to \u003cstrong\u003e40 Ethernet\/IP nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 16 local 5069 Compact I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB 2.0 (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNon-volatile Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 GB (via 1784-SD2 card)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Expanded Memory \u0026amp; Node Capacity\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 MB of user memory\u003c\/strong\u003e, the 5069-L320ER provides double the capacity of the L310 series. This makes it ideal for applications involving extensive recipes, advanced alarm handling, or large data-logging buffers. Its support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e40 Ethernet\/IP nodes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for the integration of a vast array of remote I\/O, PowerFlex drives, and HMI panels.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. High-Performance Backplane\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eAs part of the 5380 series, this controller utilizes the high-speed 5069 backplane. This architecture provides significantly faster I\/O scan times and improved determinism compared to older 1769-series controllers, allowing for more precise control over high-speed machinery.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Advanced Gigabit Networking\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe dual 1-Gbps Ethernet ports can be configured in two primary ways:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides physical and logical network segmentation, allowing you to keep machine-level I\/O traffic isolated from the plant’s enterprise network for better security and performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDevice Level Ring (DLR):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures network resiliency. If a single point of failure occurs in the Ethernet ring, the system maintains communication, preventing unnecessary downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 5069-L320ER and 5069-L320ERM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"M\" in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion stands for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMotion\u003c\/strong\u003e. The L320ERM supports up to 8 axes of Integrated CIP Motion (servo control). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL320ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis for standard logic applications and does not support coordinated servo motion over EtherNet\/IP.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is power distributed to this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5069 platform uses a split-power architecture:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers the internal controller logic and circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power (Sensor\/Actuator):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides power to the field-side circuitry of the connected I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller require a battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The CompactLogix 5380 series uses internal capacitors to back up the user program to non-volatile memory during a power failure, eliminating the need for lithium battery maintenance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting \u0026amp; Cooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller must be mounted horizontally on a standard 35 mm DIN rail. Because the high-speed processor generates heat, ensure at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2 in.)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance above and below the unit for convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Blocks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB22-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB22-SPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal block to connect the MOD and SA power feeds. These are typically sold separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Planning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the 40-node capacity, ensure your network switch infrastructure can handle the 1-Gbps throughput to take full advantage of the controller's speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L320ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the \"powerhouse\" choice for standard control. It is frequently selected for complex process skids or assembly lines where the logic complexity is high, but the mechanical movements are handled by standard AC drives or pneumatic actuators rather than synchronized servos. Its ability to manage 16 local I\/O modules also makes it excellent for high-density local control without needing remote racks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084746482027,"sku":"5069-L320ER","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L320ER.png?v=1775996325"},{"product_id":"allen-bradley-5069-ob16-compact-5000-digital-output-module","title":"Allen-Bradley 5069-OB16 Compact 5000 Digital Output Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital DC output module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley Compact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. It features 16 sourcing outputs and is designed for use with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix 5580\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(via a 5069-AENTR) controllers. This module is engineered for high-speed switching of industrial actuators, such as solenoid valves, motor starters, and indicator lights, providing a fast and deterministic interface for modern automated systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC Source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per channel (8 A max per module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSurge Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 A for 10 ms per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power (MOD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA @ 18–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor\/Actuator Power (SA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA @ 18–32V DC (plus field load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Sourcing Output Architecture\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSourcing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesign, meaning the module provides the positive voltage (+24V DC) to the load. The other side of the load is typically connected to the common (ground). This is the most common output configuration for driving industrial components in a PNP-compatible circuit.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. High-Speed Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePart of the Compact 5000 platform, this module benefits from a high-speed system backplane that ensures output commands from the controller are executed with minimal latency. This is essential for applications requiring precise timing, such as high-speed sorting or synchronized packaging movements.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Advanced Module Diagnostics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 5069-OB16 provides real-time diagnostic information to the controller, which can be viewed in Studio 5000:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetects if the field-side power supply is missing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Status LEDs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures individual green status LEDs for each of the 16 channels, allowing for rapid visual troubleshooting on the factory floor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes built-in protection against overcurrent and short-circuit conditions on a per-module basis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Removable Terminal Block (RTB) is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is compatible with the 18-pin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(screw-clamp) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(push-in) terminal blocks. Note that these are typically ordered separately from the module itself.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support RIUP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e, which allows maintenance personnel to swap out a module without powering down the entire chassis or disconnecting the field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"SA Power\" requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensor\/Actuator (SA) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be supplied to the module through the controller or a field potential distributor. This power is used to energize the output circuits and the physical devices (solenoids, etc.) connected to them.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Practice:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor inductive loads (like solenoids or relays), it is standard practice to use an external surge suppressor (flyback diode) across the load to protect the module’s internal transistors from back-EMF spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen switching high-current loads across all 16 channels simultaneously, ensure the cabinet has sufficient ventilation. Maintain at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2 in.)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance above and below the module for convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Tie-In:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the SA Power common is correctly tied to the load common to complete the electrical circuit for the sourcing outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis highly valued for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHigh Density and Reliability\u003c\/strong\u003e. By providing 16 points in a slim 22mm wide module, it allows for significant I\/O expansion in space-constrained control cabinets. Its deterministic integration with the Logix 5000 environment ensures that even complex, multi-output sequences are executed with the precision required for high-performance IIoT-ready machinery.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084747956587,"sku":"5069-OB16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-OB16.png?v=1775996986"},{"product_id":"allen-bradley-5069-rtb64-screw-removable-terminal-block","title":"Allen-Bradley 5069-RTB64-SCREW Removable Terminal Block","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB64-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, 64-pin removable terminal block (RTB) designed specifically for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This accessory is required for high-point-count modules, such as the 32-point digital input or output modules (e.g., 5069-IB32 or 5069-OB32), where standard 18-pin blocks do not provide enough termination points. The \"SCREW\" version features traditional screw-clamp connections, offering a secure and vibration-resistant interface for complex industrial wiring.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5069-RTB64-SCREW\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Pins\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size (Solid\/Stranded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22–16 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTorque Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22–0.25 N·m (2.0–2.2 lb·in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32V DC Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5069-IB32, 5069-OB32, 5069-IY4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functionalities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. High-Density Termination\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB64-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to manage the significant wiring requirements of 32-point modules within a slim 22mm module width. By utilizing a multi-tier screw-clamp arrangement, it allows 64 individual wires (inputs\/outputs and commons) to be landed in a very small physical footprint.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Support for RIUP\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eLike all RTBs in the Compact 5000 series, this block supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e. This allows maintenance teams to replace the electronic I\/O module without disturbing the field wiring, significantly reducing downtime and eliminate the risk of cross-wiring during replacement.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Mechanical Security\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe screw-clamp design is particularly effective in environments subject to constant mechanical vibration. Once tightened to the correct torque, the clamps provide a gas-tight seal that prevents oxidation and intermittent connections over the life of the control system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this RTB with a standard 16-point module like the 5069-IB16?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB64-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis physically larger and has a different pin alignment than the 18-pin blocks used for 16-point modules. It is strictly for 32-point modules or specialized analog modules designed for 64-pin interfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with the I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenerally, no. In the Allen-Bradley Compact 5000 series, Removable Terminal Blocks are sold as separate catalog items. This allows users to choose between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(5069-RTB64-SCREW) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(5069-RTB64-SPRING) push-in style connectors based on their preference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I manage such a large bundle of wires?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause 64 wires can be bulky, it is recommended to use the integrated cable tie-down points on the module housing. Using ferrules is also highly recommended to keep the wire ends neat and ensure they fit into the high-density spacing of the RTB.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Sensitivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause of the high density, the screws on the 64-pin block are smaller than those on the 18-pin blocks. It is critical to use a precision screwdriver and stay within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.22–0.25 N·m\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etorque range to avoid stripping the threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Sequence:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is best practice to wire the bottom tier first and work your way up to the top tier. This prevents previously landed wires from obstructing access to the lower terminal screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeying and Coding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the plastic keying tabs provided with the module to ensure the RTB can only be plugged into the correct type of module, preventing potential damage from mismatched voltage levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB64-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the primary enabler of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpace-Optimized I\/O\u003c\/strong\u003e. In modern control cabinets where DIN rail space is at a premium, being able to land 32 points of I\/O in a single 22mm slot is a major advantage. By using the screw-clamp version, engineers ensure that even these high-density connections remain reliable under the harsh thermal and mechanical conditions of a factory floor or a moving skid.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084749169003,"sku":"5069-RTB64-SCREW","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-RTB64-SCREW_2.png?v=1775997651"},{"product_id":"5069-l306er-allen-bradley-compact-guardlogix-5380-safety-controller","title":"5069-L306ER Allen-Bradley Compact GuardLogix 5380 Safety Controller","description":"\u003ch3\u003eCritical Product Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER (5069L306ER)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact GuardLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety controller engineered to provide integrated motion and safety control within a single hardware platform. This unit is specifically designed for complex industrial applications requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLe (Category 4)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety ratings. By utilizing a dual-processor architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexecutes safety logic and standard logic simultaneously, significantly reducing the hardware footprint and simplifying system integration. Ideal for high-speed manufacturing, automotive assembly lines, and heavy machinery, this controller optimizes system reaction times and minimizes unplanned downtime through advanced diagnostics and high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectivity. It provides a scalable solution for engineers looking to balance rigorous safety standards with maximum operational efficiency.\u003c\/p\u003e\n\u003ch3\u003eArchitectural Configuration and Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol engine to deliver high-speed processing and increased throughput. This controller is characterized by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.6 MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandard user memory and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.3 MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ededicated safety memory. The dual-port design supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 EtherNet\/IP nodes\u003c\/strong\u003e, allowing for flexible network topologies including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDevice Level Ring (DLR)\u003c\/strong\u003e, Linear, and Star configurations.\u003c\/p\u003e\n\u003cp\u003eAs part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5380 series\u003c\/strong\u003e, it operates using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStudio 5000 Logix Designer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware (Version 31 or later). The hardware design isolates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModule (MOD) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(logic side) from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSensor\/Actuator (SA) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(field side), preventing electrical noise from impacting the central processing unit and ensuring stable execution of safety instructions in electrically noisy environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley\u003c\/strong\u003e (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompact GuardLogix 5380\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIL 3 \/ PLe \/ Cat. 4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0.6 MB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0.3 MB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEtherNet\/IP Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e16 Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to \u003cstrong\u003e8 Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0 to 60 deg C\u003c\/strong\u003e (32 to 140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-40 to 85 deg C\u003c\/strong\u003e (-40 to 185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (MOD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e18 to 32 VDC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e143.97 x 98.10 x 136.81 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately \u003cstrong\u003e0.77 kg\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUSA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSafety Technical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 5069-L306ER achieve SIL 3 safety without an external safety partner?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a built-in 1oo2 (one out of two) processor architecture. The internal safety task is executed in a redundant manner, and the controller performs continuous self-diagnostics to ensure safety integrity. This allows the unit to meet\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements in a single, compact module without the need for a separate safety partner module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this controller be used with standard 5069 Compact I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both standard and safety-rated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069 Compact I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules. However, to maintain the safety integrity of a specific safety loop, you must utilize\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OBV8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety I\/O modules for the safety-related inputs and outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the SD card slot on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller includes a slot for an industrial-grade\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSecure Digital (SD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecard (1 GB standard). This is used for non-volatile storage of the user program, firmware, and safety configurations. It allows for fast \"device replacement\" without requiring a PC to reload the logic, which is critical for reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrecision Installation \u0026amp; Thermal Management\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Isolation Strategy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare sourced from separate power supplies if your application requires isolation between logic and field-side devices. Use a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClass 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSELV\/PELV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erated power supply to comply with regulatory standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo mitigate electromagnetic interference (EMI), use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIN rail\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egrounding and ensure all communication cables are shielded. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be mounted on a grounded, corrosion-resistant DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance and Airflow:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(2 inches) of clearance on all sides of the controller. This ensures adequate convection cooling and prevents thermal throttling when operating at the upper limit of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e60 deg C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etemperature range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance \u0026amp; Durability Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety Motion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis controller supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 axes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof integrated motion over EtherNet\/IP, allowing safety instructions (like Safe Torque Off) to be executed directly over the network, eliminating hard-wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt with industrial-grade components, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis rated for high-vibration environments and features a conformal coating option for protection against chemical contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Cybersecurity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware utilizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigitally signed firmware\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand controller-based change detection, providing a robust layer of defense against unauthorized code injection or tampering in mission-critical infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084783870315,"sku":"5069-L306ER","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L306ER.png?v=1775998108"}],"url":"https:\/\/www.plcprotech.com\/collections\/allen-bradley-compactlogix.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}