{"title":"Allen-Bradley MicroLogix","description":"\u003cp\u003eThe Allen-Bradley MicroLogix family (1761, 1762, 1763, 1764, 1766) offers a proven range of small, standalone controllers for basic machine automation. The architecture ranges from fixed I\/O blocks to modular expansion systems, providing flexibility for varied machine sizes. Technical characteristics include integrated high-speed counters, serial or Ethernet ports, and an embedded LCD for localized diagnostics. Functionally, MicroLogix excels in small-scale applications like conveyor control, packaging, and basic SCADA RTU tasks. While transitioning toward the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/allen-bradley-micro800\"\u003eMicro800\u003c\/a\u003e series, these robust controllers remain a staple for thousands of industrial systems, requiring reliable spare parts to maintain consistent operational uptime.\u003c\/p\u003e","products":[{"product_id":"allen-bradley-1766-l32bxba-micrologix-1400-32-point-controller","title":"Allen-Bradley 1766-L32BXBA MicroLogix 1400 32 Point Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1766-L32BXBA\u003c\/strong\u003e is a programmable logic controller within the \u003cstrong\u003eMicroLogix 1400\u003c\/strong\u003e series designed for industrial automation applications requiring a high density of discrete and analog control paths. This controller operates on a 24V DC power supply and manages a total embedded array of 32 digital points alongside integral analog processing modules. The discrete input capabilities include 12 fast 24V DC inputs and 8 standard 24V DC inputs, which couple with 6 relay outputs, 3 fast 24V DC outputs, and 3 normal 24V DC FET outputs. Furthermore, the unit integrates 4 embedded 12-bit voltage inputs and 2 embedded 12-bit analog outputs, removing the necessity for supplementary hardware modules in basic mixed-signal tracking routines. Outfitted with an isolated Ethernet port, the system facilitates industrial protocol communications including EtherNet\/IP messaging, Modbus TCP\/IP, and DNP3 over IP, ensuring full compatibility with supervising workstation infrastructures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates a diverse embedded multi-channel mix comprising 20 digital inputs, 12 digital outputs, 4 analog inputs, and 2 analog outputs.\u003c\/li\u003e\n\u003cli\u003eFeatures 12 high-speed discrete inputs and 3 fast FET outputs for rapid signal execution.\u003c\/li\u003e\n\u003cli\u003eProvides dual discrete output topologies utilizing both rugged isolation relays and fast-switching 24V DC FET channels.\u003c\/li\u003e\n\u003cli\u003eOutfitted with an isolated Ethernet port supporting multi-protocol network integration alongside serial interface capabilities.\u003c\/li\u003e\n\u003cli\u003eContains 20 KB of internal memory to process user control logic applications safely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmbedded system automation loops requiring localized mixing of high-speed discrete and analog instrumentation.\u003c\/li\u003e\n\u003cli\u003eSCADA remote terminal units utilizing DNP3 or Modbus communication configurations across water, wastewater, or utility infrastructures.\u003c\/li\u003e\n\u003cli\u003eLocalized material handling conveyors, packaging machinery control panels, and process pump skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1766-L32BXBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Input channels, 12 Output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 fast 24V DC inputs, 8 normal 24V DC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 relay outputs, 3 fast 24V DC outputs, 3 normal 24V DC FET outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmbedded Analog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Voltage Inputs (12 bits) \/ 2 Analog Outputs (12 bits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Relay and 6 24V DC FET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDF1, DH-485, Modbus RTU, ASCII, DNP3, EtherNet\/IP messaging, DNP3 over IP, Modbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet Port, Isolated Serial Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm (3.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mm (7.087 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 mm (3.43 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the controller housing securely onto a standard industrial DIN rail structure inside an environmental protective control cabinet.\u003c\/li\u003e\n\u003cli\u003eVerify that the incoming auxiliary power link delivers a regulated 24V DC voltage source matching the strict electrical profile of the hardware terminal blocks.\u003c\/li\u003e\n\u003cli\u003eSeparate instrumentation signaling lines, particularly the integrated 12-bit analog input and output loops, from neighboring high-voltage electrical lines to decrease noise coupling risks.\u003c\/li\u003e\n\u003cli\u003eGround the controller chassis using the dedicated grounding terminal path to guarantee reliable internal diagnostic operations and optimize electrostatic immunity thresholds.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695173759339,"sku":"1766-L32BXBA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1766-l32bxba-micrologix-1400-plc-1nsjzz1wqgz_c02cd092-d614-41fb-a7b2-43f9cc939a28.jpg?v=1766114468"},{"product_id":"allen-bradley-1761-l32awa-micrologix-1000-32-point-programmable-controller","title":"Allen-Bradley 1761-L32AWA MicroLogix 1000 32-Point Programmable Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1761-L32AWA\u003c\/strong\u003e is a fixed-I\/O \u003cstrong\u003eMicroLogix 1000 programmable controller\u003c\/strong\u003e for standalone machine and process control. It integrates an AC power supply, processor, memory, discrete I\/O, and serial communication functions.\u003c\/p\u003e\n\u003cp\u003eThe controller provides 20 digital inputs for 120V AC field signals and 12 relay outputs. The relay contacts can switch supported AC or DC loads used by contactors, motor starters, solenoids, indicators, and other control devices.\u003c\/p\u003e\n\u003cp\u003eA built-in \u003cstrong\u003eRS-232 interface\u003c\/strong\u003e supports \u003cstrong\u003eDF1 communication\u003c\/strong\u003e for programming, monitoring, and controller communication. The control program is retained in nonvolatile EEPROM memory.\u003c\/p\u003e\n\u003cp\u003eThe compact controller supports DIN rail or screw mounting inside an industrial enclosure. Horizontal mounting provides the full specified operating temperature range.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFixed controller architecture with integrated processor, power supply, and discrete I\/O\u003c\/li\u003e\n\u003cli\u003eNonvolatile EEPROM program storage\u003c\/li\u003e\n\u003cli\u003eRelay outputs for supported AC and DC loads\u003c\/li\u003e\n\u003cli\u003eDF1 serial communication through the RS-232 interface\u003c\/li\u003e\n\u003cli\u003eDIN rail or mounting-screw installation\u003c\/li\u003e\n\u003cli\u003eHorizontal or vertical enclosure mounting\u003c\/li\u003e\n\u003cli\u003eFunctional earth connection for noise immunity\u003c\/li\u003e\n\u003cli\u003eReplaceable wiring without separate plug-in I\/O modules\u003c\/li\u003e\n\u003cli\u003eSurge suppression support for inductive output loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandalone machine control\u003c\/li\u003e\n\u003cli\u003eConveyor sequencing\u003c\/li\u003e\n\u003cli\u003eMotor starter control\u003c\/li\u003e\n\u003cli\u003eSolenoid valve control\u003c\/li\u003e\n\u003cli\u003ePump and fan control\u003c\/li\u003e\n\u003cli\u003ePackaging equipment\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems\u003c\/li\u003e\n\u003cli\u003eRelay-based equipment interlocking\u003c\/li\u003e\n\u003cli\u003eSmall production machinery\u003c\/li\u003e\n\u003cli\u003eEquipment status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1761-L32AWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnique Product Identifier\u003c\/td\u003e\n\u003ctd\u003e1761-L32AWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662468368704\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1000, 120\/240V AC power, 20 120V AC digital inputs, and 12 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Class\u003c\/td\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1761-L32AWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFixed-I\/O Programmable Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Digital I\/O\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eDF1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e1K EEPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram and Data Capacity\u003c\/td\u003e\n\u003ctd\u003eApproximately 737 instruction words and 437 data words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Power Supply\u003c\/td\u003e\n\u003ctd\u003e120\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85...264V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Usage at 120V AC\u003c\/td\u003e\n\u003ctd\u003e19 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Usage at 240V AC\u003c\/td\u003e\n\u003ctd\u003e25 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A for 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Power Cycles\u003c\/td\u003e\n\u003ctd\u003e50,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eDigital Input Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Controller Class\u003c\/td\u003e\n\u003ctd\u003e100...120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e79...132V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e47...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum On-State Voltage\u003c\/td\u003e\n\u003ctd\u003e79V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-State Voltage\u003c\/td\u003e\n\u003ctd\u003e132V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e20V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum On-State Current\u003c\/td\u003e\n\u003ctd\u003e5.0 mA at 79V AC, 47 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal On-State Current\u003c\/td\u003e\n\u003ctd\u003e12.0 mA at 120V AC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-State Current\u003c\/td\u003e\n\u003ctd\u003e16.0 mA at 132V AC, 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Current\u003c\/td\u003e\n\u003ctd\u003e2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Impedance at 50 Hz\u003c\/td\u003e\n\u003ctd\u003e12K ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Impedance at 60 Hz\u003c\/td\u003e\n\u003ctd\u003e10K ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Inrush\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eRelay Output Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e10.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load per Controller\u003c\/td\u003e\n\u003ctd\u003e1440 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Common\u003c\/td\u003e\n\u003ctd\u003e8.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-to-On Response\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-to-Off Response\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Relay Life\u003c\/td\u003e\n\u003ctd\u003e20,000,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eRelay Contact Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Voltage\u003c\/th\u003e\n\u003cth\u003eMake Current\u003c\/th\u003e\n\u003cth\u003eBreak Current\u003c\/th\u003e\n\u003cth\u003eContinuous Current\u003c\/th\u003e\n\u003cth\u003eMake Rating\u003c\/th\u003e\n\u003cth\u003eBreak Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e240V AC\u003c\/td\u003e\n\u003ctd\u003e7.5 A\u003c\/td\u003e\n\u003ctd\u003e0.75 A\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003ctd\u003e1800 VA\u003c\/td\u003e\n\u003ctd\u003e180 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003ctd\u003e1.5 A\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003ctd\u003e1800 VA\u003c\/td\u003e\n\u003ctd\u003e180 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e125V DC\u003c\/td\u003e\n\u003ctd\u003e0.22 A\u003c\/td\u003e\n\u003ctd\u003e0.22 A\u003c\/td\u003e\n\u003ctd\u003e1.0 A\u003c\/td\u003e\n\u003ctd\u003e28 VA\u003c\/td\u003e\n\u003ctd\u003e28 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003ctd\u003e28 VA\u003c\/td\u003e\n\u003ctd\u003e28 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eDo not exceed the specified current per common. For DC applications, relay make and break ratings depend on the applied voltage.\u003c\/p\u003e\n\u003ch4\u003eMechanical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e200 mm (7.87 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e80 mm (3.15 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e73 mm (2.87 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Methods\u003c\/td\u003e\n\u003ctd\u003eDIN rail or mounting screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Minimum Clearance\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2 in.) at the top, bottom, and sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Terminal Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.9 N.m (8.0 in.lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eWiring Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolid Wire Size\u003c\/td\u003e\n\u003ctd\u003e14...22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStranded Wire Size\u003c\/td\u003e\n\u003ctd\u003e16...22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Conductors per Terminal Screw\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Spade Lug for 22...16 AWG\u003c\/td\u003e\n\u003ctd\u003eAMP 53120-1 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Spade Lug for 16...14 AWG\u003c\/td\u003e\n\u003ctd\u003eAMP 53123-1 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Screw Head Diameter\u003c\/td\u003e\n\u003ctd\u003e5.5 mm (0.220 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature, Horizontal Mounting\u003c\/td\u003e\n\u003ctd\u003e0...55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature, Vertical Mounting\u003c\/td\u003e\n\u003ctd\u003e0...40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration, Panel Mounted\u003c\/td\u003e\n\u003ctd\u003e5 Hz...2 kHz, 0.381 mm peak-to-peak, 2.5g, 1 hour per axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Vibration\u003c\/td\u003e\n\u003ctd\u003e5 Hz...2 kHz, 0.762 mm peak-to-peak, 5g, 1 hour per axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e10g peak acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock, DIN Rail Mounted\u003c\/td\u003e\n\u003ctd\u003e7.5g peak acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Shock\u003c\/td\u003e\n\u003ctd\u003e20g peak acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrostatic Discharge\u003c\/td\u003e\n\u003ctd\u003eEN 61000-2 at 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Transient\u003c\/td\u003e\n\u003ctd\u003eEN 61000-4 at 2 kV on power supply and I\/O; 1 kV on communication circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eRelay-equipped 32-point controllers require an additional 2.5g derating for the specified shock rating.\u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Power Input\u003c\/td\u003e\n\u003ctd\u003eSupplies operating power from a 120\/240V AC source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs I\/0...I\/19\u003c\/td\u003e\n\u003ctd\u003eAccept 20 discrete 120V AC input signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs O\/0...O\/11\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 supported AC or DC output loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Common Terminals\u003c\/td\u003e\n\u003ctd\u003eProvide common connections for relay output groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-232 Port\u003c\/td\u003e\n\u003ctd\u003eSupports DF1 programming and controller communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Earth Terminal\u003c\/td\u003e\n\u003ctd\u003eProvides a low-impedance earth path for noise immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the controller inside an enclosure.\u003c\/li\u003e\n\u003cli\u003eMount the controller horizontally when the full operating temperature range is required.\u003c\/li\u003e\n\u003cli\u003eUse either a DIN rail or mounting screws for horizontal installation.\u003c\/li\u003e\n\u003cli\u003eUse mounting screws for greater stability when mounting vertically.\u003c\/li\u003e\n\u003cli\u003ePosition the nameplate downward for vertical mounting.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 50.8 mm of clearance at the top, bottom, and sides.\u003c\/li\u003e\n\u003cli\u003eKeep the protective wrap installed while drilling and wiring.\u003c\/li\u003e\n\u003cli\u003ePrevent metal chips and wire fragments from entering the controller.\u003c\/li\u003e\n\u003cli\u003eRemove the protective wrap after wiring to prevent overheating.\u003c\/li\u003e\n\u003cli\u003eConnect the functional earth terminal directly to the ground bus.\u003c\/li\u003e\n\u003cli\u003eUse the heaviest permitted conductor for the ground connection.\u003c\/li\u003e\n\u003cli\u003eTighten terminal screws to no more than 0.9 N.m.\u003c\/li\u003e\n\u003cli\u003eInstall surge suppression directly across inductive loads.\u003c\/li\u003e\n\u003cli\u003ePosition suppression devices as close as possible to the controlled load.\u003c\/li\u003e\n\u003cli\u003eDo not connect or disconnect equipment while energized in a hazardous location.\u003c\/li\u003e\n\u003cli\u003eUse only approved communication cables in Class I, Division 2 installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eC-UL\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C, and D, when marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\u003c\/td\u003e\n\u003ctd\u003eUL Listed for Class I, Division 2, Groups A, B, C, and D, when marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003ctd\u003eCompliant with applicable directives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRCM\u003c\/td\u003e\n\u003ctd\u003eCompliant with applicable directives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAC\u003c\/td\u003e\n\u003ctd\u003eCompliant with applicable directives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Suitability\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C, and D, or nonhazardous locations when marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695180280171,"sku":"1761-L32AWA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1761-l32awa-micrologix-1000-controller-unit-e1jpiuuvanz_75ec0d24-6a5e-457a-9e1b-10c2ffa523ed.jpg?v=1766114259"},{"product_id":"allen-bradley-1761-net-aic-aic-advanced-interface-converter","title":"Allen-Bradley 1761-NET-AIC AIC+ Advanced Interface Converter","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The \u003cstrong\u003eAllen-Bradley 1761-NET-AIC\u003c\/strong\u003e is a high-performance \u003cstrong\u003eAIC+ advanced interface converter\u003c\/strong\u003e engineered to provide a reliable, isolated electronic communication link between various networked automation components. Operating as an intelligent protocol and physical layer adapter, the module features built-in electrical isolation to establish point-to-point or multidrop routing across diverse serial networks without risking ground loop faults. By utilizing dual RS-232 pathways combined with a dedicated RS-485 port interface, this device smoothly links controllers, personal computer configurations, operator terminals, and modems across demanding shop floor networks.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTriple Port Interface:\u003c\/strong\u003e Integrated architecture offering one RS-485 Phoenix plug connection, an 8-pin mini-DIN RS-232 port, and a conventional 9-pin DB-9 DTE RS-232 communication port.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Electrical Isolation:\u003c\/strong\u003e Delivers 500V DC internal electrical isolation boundary limits between all communication ports and the active power supply terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Operational Clocking:\u003c\/strong\u003e Built-in communication-rate selector switch supports distinct transmission steps including 1200, 2400, 4800, 9600, 14400, and 19200 bps, alongside an automated AUTO position mode.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdaptable Power Sourcing:\u003c\/strong\u003e Built-in DC power-source selector switch allows the module to extract active power directly from a connected MicroLogix controller or use external 24V DC auxiliary block terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Networking Range:\u003c\/strong\u003e Extends a standard DH-485, DF1, or user network multidrop segment up to 1219 m (4000 ft) with a total allowance of up to 32 nodes per network link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eMultidrop DH-485 or DF1 industrial network extensions connecting modular SLC 500 and compact MicroLogix controller nodes.\u003c\/li\u003e\n  \u003cli\u003eIsolation interfaces between local supervisory computer workstations (PC serial COM ports) and high-voltage factory networks.\u003c\/li\u003e\n  \u003cli\u003eDistributed multi-node configurations linking remote PanelView operator graphic terminals to distributed control backplanes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eAttribute\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCatalog Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1761-NET-AIC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAIC+ Advanced Interface Converter\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e24V DC Power Source Requirement\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e20.4 to 28.8V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Draw\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 120 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInrush Current (Max.)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e200 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInternal Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e500V DC between all ports and power supply terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupported Network Protocols\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDH-485, DF1, or User Network ASCII\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMax. Nodes per Multidrop Link\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e32 nodes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMax. Network Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1219 m (4000 ft) per multidrop network\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMax. Ganged Multidrop Networks\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommunication Rates\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1200, 2400, 4800, 9600, 14400, 19200 bps and AUTO\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Ambient Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 85 degC (-40 to 175 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eU.S.A.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eInterface Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eDescription \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRS-485 Port (Phoenix Plug)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTerminal 1: Chassis Ground | Terminal 2: Shield | Terminal 3: Common | Terminal 4: B | Terminal 5: A | Terminal 6: Termination\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRS-232 Port (8-pin mini-DIN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary communication connection designed to interface with MicroLogix controllers; capable of drawing internal operational power.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRS-232 Port (DB-9, DTE)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eStandard 9-pin serial layout matching personal computer COM channels, PanelView graphic units, modems, or alternative DTE lines.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eExternal Power Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eScrew block connection points for dedicated auxiliary external 24V DC supply lines and structural ground wire runs.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eATTENTION: EXPLOSION HAZARD.\u003c\/strong\u003e Substitution of components may impair suitability for Class I, Division 2 environments. Do not replace components or disconnect equipment unless power has been switched off or the installation area is known to be nonhazardous. Do not operate switches or mating cables while the circuit is live.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eEnclosure Selection:\u003c\/strong\u003e Install the interface converter inside a protective industrial enclosure. All interconnecting data cables must remain housed within the enclosure or be shielded using rigid electrical conduit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eDIN Rail Assembly:\u003c\/strong\u003e Snap the converter housing directly onto a standardized top-hat style DIN rail channel, or mount it securely to a backpanel plane using the integrated mounting feet holes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003ePower Switch Selection:\u003c\/strong\u003e Position the DC power-source selector switch before activating the lines. Set the switch to EXTERNAL when using independent 24V DC terminal feeds, or set it to CABLE if deriving internal power directly from a MicroLogix 8-pin mini-DIN cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eRS-485 Cable Termination:\u003c\/strong\u003e For end-of-line nodes on a daisy-chained RS-485 trunk line using Belden #3106A or #9842 cable, connect a short wire jumper between Terminal 1 (Chassis Ground) and Terminal 2 (Shield) on one end to provide a single, secure earth path.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e5\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eBaud Rate Optimization:\u003c\/strong\u003e Keep the communication-rate selector switch set to the AUTO position for standard installations. In environments with severe electromagnetic noise or interference, switch it to manual and set it to match the exact fixed baud rate of the network.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eUL 1604 Standard\u003c\/li\u003e\n  \u003cli\u003eC-UL C22.2 No. 213\u003c\/li\u003e\n  \u003cli\u003eClass I, Division 2, Groups A, B, C, D Hazardous Locations\u003c\/li\u003e\n  \u003cli\u003eCE Compliant (Council Directive 89\/336\/EEC EMC \/ Council Directive 73\/23\/EEC Low Voltage)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695180935531,"sku":"1761-NET-AIC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1761-net-aic-micrologix-and-slc-communication-adaptor-z0toe1mj3ov_ea878e4d-8e8f-4925-9659-179743b23b9f.jpg?v=1766114284"},{"product_id":"allen-bradley-1761-l16bwb-micrologix-1000-programmable-controller","title":"Allen-Bradley 1761-L16BWB MicroLogix 1000 Programmable Controller","description":"\u003cp\u003eThe \u003cstrong\u003e1761-L16BWB\u003c\/strong\u003e is a compact \u003cstrong\u003eprogrammable controller\u003c\/strong\u003e belonging to the MicroLogix 1000 product line. This electronic processor functions as a localized control block designed to modernize hardwired control logic systems within machine control configurations, localized factory automation setups, and designated process loops. Powered by an external 24V DC utility framework, the module maintains direct discrete tracking through integrated digital channels, executing instruction words via internal memory logic blocks.\u003c\/p\u003e\n\u003cp\u003eTo enable technical updates, diagnostic tracing, and commissioning loops, the \u003cstrong\u003e1761-L16BWB\u003c\/strong\u003e features an RS232 serial communication interface supporting the native DF1 protocol format. This dedicated connection port allows cross-system link setups to Human Machine Interfaces (HMI), Supervisory Control and Data Acquisition (SCADA) packages, and peripheral hardware converters. The controller can also adapt to external multi-node DH485 networks using a separate advanced interface converter or execute adjustments through a physical hand-held setup interface.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in 16-point integrated I\/O configuration optimizing local physical space.\u003c\/li\u003e\n\u003cli\u003eIntegrated communication channel backing native serial point-to-point interface.\u003c\/li\u003e\n\u003cli\u003eDual sinking and sourcing wiring options for versatile sensor configuration.\u003c\/li\u003e\n\u003cli\u003eInternal EEPROM storage framework ensuring reliable parameter preservation without battery dependencies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery manufacturing and localized operational line sequencing.\u003c\/li\u003e\n\u003cli\u003eFactory floor process automation nodes.\u003c\/li\u003e\n\u003cli\u003eWater, wastewater treatment, and HVAC equipment control loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSeries \/ Revision Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1761-L16BWB Ser A\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\/A, Series A, Rev A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1761-L16BWB Ser B\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\/B, Series B, Rev B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1761-L16BWB Ser C\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\/C, Series C, Rev C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1761-L16BWB Ser D\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\/D, Series D, Rev D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1761-L16BWB Ser E\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\/E, Series E, Rev E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller (PLC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662468554497\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Count\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e20.4-26.4V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30A for 4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of Inputs\u003c\/td\u003e\n\u003ctd\u003eTen (10); Sinking \/ Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Type\u003c\/td\u003e\n\u003ctd\u003e14 - 30V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e24V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSix (6); Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e6 Contact Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Size and Type\u003c\/td\u003e\n\u003ctd\u003e1 K EEPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003eApprox. 737 instruction words and 437 data words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eRS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eDF1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Feature\u003c\/td\u003e\n\u003ctd\u003eMaster Control Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Power Cycles\u003c\/td\u003e\n\u003ctd\u003e50,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e10 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Operating Shock\u003c\/td\u003e\n\u003ctd\u003e20 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 lbs (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller securely in a horizontal orientation to ensure proper ventilation and thermal cooling across internal electronic elements.\u003c\/li\u003e\n\u003cli\u003eRoute all low-voltage signal wiring separately from high-voltage electrical lines to eliminate signal crossover or EMI\/RFI noise distortion.\u003c\/li\u003e\n\u003cli\u003eEstablish a direct, low-impedance ground connection from the chassis earth terminal to the main system enclosure backplane.\u003c\/li\u003e\n\u003cli\u003eEnsure power sourcing requirements match the specified 20.4-26.4V DC bounds before energizing input terminal rows.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695181459819,"sku":"1761-L16BWB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1761-l16bwb-micrologix-1000-controller-hn1dzc0nzcf_3354eb5a-107e-4225-932b-c0f7f3df0621.jpg?v=1766114303"},{"product_id":"1763-l16bbb-allen-bradley-micrologix-1100-16-point-plc-controller","title":"1763-L16BBB Allen-Bradley MicroLogix 1100 16-Point PLC Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-946\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e1763-L16BBB (1763L16BBB)\u003c\/strong\u003e\u003cspan class=\"citation-946 citation-end-946\"\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile, compact controller within the MicroLogix 1100 family, designed to provide high-end features like online editing and built-in Ethernet\/IP at a micro-PLC price point.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with 16 integrated I\/O points (comprising 10 digital inputs, 2 analog inputs, and 6 digital outputs), this unit is a preferred choice for remote monitoring stations, building automation, and distributed control in the oil and gas sector. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1763-L16BBB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eempowers engineers to make real-time programming changes without shutting down the process, effectively eliminating downtime during commissioning.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-945 citation-end-945\"\u003eIts integrated LCD screen provides immediate diagnostic feedback and allows for the adjustment of internal integer and bit files without the need for an external HMI.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-944\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e1763-L16BBB\u003c\/strong\u003e\u003cspan class=\"citation-944 citation-end-944\"\u003e\u003cspan\u003e \u003c\/span\u003eis powered by a 24 VDC supply and features a sophisticated I\/O arrangement.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-943 citation-end-943\"\u003eThe input section consists of ten 24 VDC digital inputs, including four high-speed inputs (40 kHz) capable of high-frequency pulse counting and motion sensing.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-942 citation-end-942\"\u003eAdditionally, it provides two 10-bit analog voltage inputs (0-10 VDC) integrated directly into the base.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe output side is optimized for high-speed switching and flexibility, featuring two 24 VDC FET outputs and four isolated relay outputs.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-941 citation-end-941\"\u003eFor connectivity, the controller boasts dual communication ports: an isolated RS-232\/RS-485 combo port and a full-featured 10\/100 Mbps EtherNet\/IP port, supporting peer-to-peer messaging and remote programming across local or wide-area networks.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1763-L16BBB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ Singapore\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 (24 VDC Sink\/Source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 (0-10 VDC, 10-bit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 24 VDC FET \/ 4 Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Speed I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Inputs (40 kHz) \/ 2 Outputs (40 kHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 KB (4 KB User Program \/ 4 KB User Data)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet\/IP, RS-232, RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1763-L16BBB be used for high-speed motion control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the controller features two high-speed PTO (Pulse Train Output) or PWM (Pulse Width Modulation) outputs via its FET channels. These are ideal for basic stepper motor control or proportional valve modulation in compact machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Ethernet port compatible with standard office networks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe EtherNet\/IP port uses standard RJ45 connectors and TCP\/IP protocols. However, for industrial reliability, it is recommended to use shielded Cat5e or Cat6 cabling to prevent signal drops caused by high-voltage motor cables or variable frequency drives (VFDs).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat expansion modules are compatible with this base controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1763-L16BBB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports up to four 1762 series expansion I\/O modules. These modules connect to the right side of the controller via a bus interface, allowing for additional digital, analog, or temperature-sensing (TC\/RTD) points.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFET Output Polarity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the two 24 VDC FET outputs, ensure that the polarity is strictly observed. Unlike relay outputs, FET outputs are solid-state and polarity-sensitive. Reversing the 24 VDC supply or the load connection can cause immediate failure of the output circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Signal Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe two embedded 0-10 VDC analog inputs share a common return and provide 10-bit resolution. For precision applications requiring 12-bit or 16-bit accuracy, or for 4-20 mA signals, use a 1762-IF4 expansion module instead of the built-in terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnline Editing Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1763-L16BBB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports online editing, engineers should verify all rung logic changes in a simulation environment before applying them to a live process. Sudden changes in timer values or output states during a machine cycle can lead to mechanical stress or safety hazards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough rated for up to 65 deg C, if the controller is installed in an outdoor enclosure (e.g., a wellhead site), ensure the cabinet is vented or equipped with a heat sink to prevent the internal LCD from fading due to prolonged exposure to extreme thermal conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695183556971,"sku":"Allen Bradley 1763-L16BBB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1763-l16bbb-micrologix-1100-16-point-controller-ppiovh01k0k_a3109e4e-ee9e-496a-acd3-e193fb8ecae5.jpg?v=1766114381"},{"product_id":"1764-24awa-allen-bradley-micrologix-1500-24-point-base-unit","title":"1764-24AWA Allen-Bradley MicroLogix 1500 24-Point Base Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA (176424AWA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-density foundational base for the Allen-Bradley MicroLogix 1500 controller system. This 120\/240 VAC powered unit features 24 integrated I\/O points, specifically designed to bridge the gap between compact micro-PLCs and larger modular systems. Ideal for distributed control in wastewater management, pharmaceutical secondary packaging, and precision assembly lines, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the essential power supply and I\/O interface required to support a 1764-LRP or 1764-LSP processor. By decoupling the processor from the I\/O base, this architecture allows for rapid maintenance and upgrades with zero rewiring, significantly lowering the Total Cost of Ownership (TCO) and reducing critical system downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a split-architecture design where the base unit contains the power supply, input\/output circuitry, and expansion ports. It is equipped with 12 isolated 120 VAC inputs and 12 relay outputs, making it natively compatible with high-voltage field devices without requiring interposing relays. The unit features an integrated expansion port that supports up to 16 Compact I\/O (1769 series) modules, allowing for massive scalability. The internal power supply is engineered to handle industrial-grade voltage fluctuations, while the relay outputs are rated for heavy-duty cycling, ensuring long-term mechanical reliability in high-vibration or high-cycle environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1764-24AWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ Singapore\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85-265 VAC (47-63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Points (120 VAC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Points (Relay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExpansion Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 16 1769 Compact I\/O Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e138 x 168 x 87 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I operate the 1764-24AWA base unit without a processor module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a base unit only. It requires a 1764-LSP or 1764-LRP processor module plugged into the front interface to function as a complete programmable logic controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum output current rating for the relay contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe relay outputs on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare typically rated for a continuous current of 2.0 A per point, with a maximum controlled load of 1440 VA for AC. Always verify your specific inductive load requirements against the NEMA ICS ratings provided in the manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to mix AC and DC expansion modules with this AC base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the base unit uses 120 VAC inputs, you can add 1769 series Compact I\/O expansion modules (Digital DC, Analog, or Thermocouple) to the right side of the unit to accommodate diverse field signal requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Hot-Plugging Warning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNever attempt to install or remove the 1764-LSP\/LRP processor module while power is applied to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebase. This can cause electrical arcing across the backplane pins, potentially corrupting the processor memory or causing permanent hardware failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Bus Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen expanding the system with 1769 Compact I\/O modules, ensure that a 1769-ECR or 1769-ECL end cap is securely installed at the end of the I\/O bank. Without the end cap, the I\/O bus will remain an open circuit, and the processor will flag a major non-recoverable fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInductive Load Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven that this base unit utilizes relay outputs, switching inductive loads (such as motor contactors or solenoids) generates significant Back-EMF. It is mandatory to install MOV (Metal Oxide Varistors) or RC snubbers across AC loads to prevent electromagnetic interference from resetting the internal processor logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695183917419,"sku":"Allen Bradley 1764-24AWA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1764-24awa-micrologix-1500-base-unit-imukxjybyqv_3cbde214-b442-4ab1-9bb5-ec02af3178b7.jpg?v=1766114395"},{"product_id":"allen-bradley-1762-l40bwa-micrologix-1200-40-point-controller","title":"Allen-Bradley 1762-L40BWA MicroLogix 1200 40 Point Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-931\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e1762-L40BWA (1762L40BWA)\u003c\/strong\u003e\u003cspan class=\"citation-931 citation-end-931\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, compact programmable logic controller within the MicroLogix 1200 family, engineered to handle complex industrial applications with a small physical footprint.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFeaturing 40 integrated I\/O points (24 inputs and 16 outputs), this controller is a staple in critical infrastructure such as municipal water pumping stations, material handling conveyors, and specialized packaging machinery. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the processing power necessary to reduce cycle times and optimize throughput. Its robust design ensures high reliability in demanding environments, minimizing unplanned downtime and maintaining system stability in 120\/240 VAC powered architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware architecture is designed for versatility and expansion.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-930 citation-end-930\"\u003eIt features 24 VDC sink\/source inputs and highly durable relay outputs, allowing it to interface directly with various field devices.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-929 citation-end-929\"\u003eThe unit is powered by a 120\/240 VAC supply, eliminating the need for external DC power modules for the base controller operation.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCommunication is handled via an isolated RS-232 port, supporting DF1, DH-485, and Modbus RTU protocols for seamless integration into existing SCADA or HMI networks. The controller’s memory is flash-based, protecting user programs and data without the absolute necessity of battery backup, though a battery (1747-BA) is supported for long-term data retention.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1762-L40BWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ Malaysia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Sink\/Source (24 points)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay (16 points)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100-240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 KB (approx. 4 KB Instruction\/2 KB Data)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 (8-pin mini-DIN)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 x 160 x 87 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.95 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1762-L40BWA support I\/O expansion beyond the built-in 40 points?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MicroLogix 1200 series supports up to six 1762 expansion I\/O modules. These modules are connected via a ribbon cable on the right side of the unit, allowing for a significant increase in digital or analog point counts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software is required to program this specific controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis programmed using RSLogix 500 software or MicroLogix-specific versions of the same suite. It is compatible with Windows-based environments and utilizes a standard ladder logic programming structure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I reset the controller to factory defaults if the password is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eResetting the controller usually requires a specific memory clearing procedure or a factory-authorized \"Master Password\" depending on the firmware version. Note that a factory reset will erase all stored ladder logic and data tables.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Output Longevity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo extend the life of the internal relay contacts, always install an external suppression circuit (such as an RC snubber for AC loads or a diode for DC loads) when switching inductive loads like solenoids or motor starters. This prevents contact arcing and premature failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail and Panel Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the unit supports DIN rail mounting, for high-vibration environments (such as rock crushing or heavy stamping), it is recommended to use the integrated screw mounting holes for a more secure, direct-to-panel installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Noise Reduction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the \"Chassis Ground\" terminal is connected to a low-impedance earth ground using a short, heavy-gauge wire. This is critical for protecting the internal 24 VDC sensor power supply and ensuring stable RS-232 communication signals in electrically noisy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695188537707,"sku":"1762-L40BWA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1762-l40bwa-micrologix-1200-40-point-controller-ed4xi5bj2x3_3724e6e5-154e-4b4f-bc96-12ed5d3b362a.jpg?v=1766114546"},{"product_id":"allen-bradley-1762-l24bwar-micrologix-1200-24-point-controller","title":"Allen-Bradley 1762-L24BWAR MicroLogix 1200 24 Point Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1762-L24BWAR\u003c\/strong\u003e is a 24-point programmable logic controller belonging to the \u003cstrong\u003eMicroLogix 1200\u003c\/strong\u003e product series. It serves as a compact and reliable processing module for localized machine-level industrial automation. Operating on a 120\/240V AC power supply, the unit delivers integrated input\/output processing via 14 digital 24V DC inputs—configured as 10 standard inputs and 4 fast high-speed inputs—combined with 10 digital relay outputs. This Series C revision features an integrated auxiliary Programming\/HMI port alongside its primary interface to allow concurrent terminal or peripheral messaging.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnified fixed controller configuration supporting a 24-point localized I\/O array.\u003c\/li\u003e\n\u003cli\u003eConfigured with 14 discrete 24V DC inputs, utilizing 4 fast points specialized for high-speed counter tasks.\u003c\/li\u003e\n\u003cli\u003eProvides 10 isolated mechanical relay outputs capable of multi-voltage load switching.\u003c\/li\u003e\n\u003cli\u003eEquipped with an additional specialized Programming\/HMI port to facilitate localized monitoring.\u003c\/li\u003e\n\u003cli\u003eSystem expansion ready, allowing up to four discrete 1762 I\/O expansion modules to fit customized applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLocalized machine control and packaging machinery.\u003c\/li\u003e\n\u003cli\u003eMulti-axis material handling and conveyor automation.\u003c\/li\u003e\n\u003cli\u003eSCADA RTU nodes and distributed pumping control installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1762-L24BWAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Power Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of I\/O Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 total: 10 Standard 24V DC, 4 Fast 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Relay Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh-Speed Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 20 kHz (on fast inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-state Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 to 30.0V DC (at 30 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-state Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x Programming\/HMI Port, Expansion Bus Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mm (4.33 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm (3.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 mm (3.43 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the device within a clean industrial enclosure, maintaining a required clearance of at least 50 mm (2 in.) on all sides to allow proper ventilation and thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eAttach firmly to a standard symmetric DIN rail or use the integrated screw mounting holes for secure flat panel installation.\u003c\/li\u003e\n\u003cli\u003eRoute high-voltage AC input lines and low-voltage 24V DC I\/O lines through separate wiring conduits to limit local electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eConnect the frame ground terminal directly to a low-impedance master ground system before completing auxiliary I\/O terminations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53434514473323,"sku":"1762-L24BWAR","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1762-L24BWAR_1.jpg?v=1782716996"},{"product_id":"allen-bradley-1766-l32bwa-series-c-micrologix-1400-32-point-controller","title":"Allen-Bradley 1766-L32BWA Series C MicroLogix 1400 32-Point Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1766-L32BWA\u003c\/strong\u003e is a MicroLogix 1400 32-point programmable controller with integrated digital I\/O and Ethernet communication.\u003c\/p\u003e\n\u003cp\u003eThis configuration provides \u003cstrong\u003e20 digital 24 VDC inputs\u003c\/strong\u003e and \u003cstrong\u003e12 relay outputs\u003c\/strong\u003e. The inputs include 12 high-speed channels and eight standard channels.\u003c\/p\u003e\n\u003cp\u003eThe controller uses a \u003cstrong\u003e100 to 240 VAC power supply\u003c\/strong\u003e and provides an isolated 24 VDC sensor power output. The MicroLogix 1400 platform includes 20 KB of memory, online editing, data logging, recipe storage, and expansion support.\u003c\/p\u003e\n\u003cp\u003eIntegrated communication includes an Ethernet port supporting EtherNet\/IP, Modbus TCP\/IP, and DNP3 over IP. Serial communication supports DF1, DH-485, Modbus RTU, ASCII, and DNP3.\u003c\/p\u003e\n\u003cp\u003eThe supplied unit is identified as \u003cstrong\u003eSeries C with firmware revision 21\u003c\/strong\u003e. Rockwell Automation currently lists catalog number 1766-L32BWA with an \u003cstrong\u003eActive Mature\u003c\/strong\u003e lifecycle status.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMicroLogix 1400 programmable controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e32 embedded digital I\/O points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e20 digital 24 VDC inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12 relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12 high-speed DC inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEight standard DC inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100 to 240 VAC power supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated 24 VDC sensor power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e20 KB controller memory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOnline program editing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData logging capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecipe storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmbedded real-time clock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmbedded Ethernet communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS-232 and RS-485 communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEtherNet\/IP support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModbus TCP\/IP support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModbus RTU support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDNP3 communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to seven 1762 expansion I\/O modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMachine control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaterial handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePump and motor control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall process control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed equipment control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial monitoring and data logging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement of installed MicroLogix 1400 controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1766-L32BWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e32-Point Programmable Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Embedded I\/O\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Inputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e12 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Analog I\/O\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e20 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eActive Mature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598518104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eRockwell currently identifies the 1766-L32BWA as a MicroLogix 1400 32-point controller with 12 fast 24 VDC inputs, eight normal 24 VDC inputs, 12 relay outputs, and 110\/240 VAC power.\u003c\/p\u003e\n\u003ch3\u003ePower Supply\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Tolerance\u003c\/td\u003e\n\u003ctd\u003e-15% \/ +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 VAC Inrush Current\u003c\/td\u003e\n\u003ctd\u003e25 A for 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240 VAC Inrush Current\u003c\/td\u003e\n\u003ctd\u003e40 A for 4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Output\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Capacitance\u003c\/td\u003e\n\u003ctd\u003e400 µF maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe MicroLogix 1400 selection guide groups the 1766-L32BWA with the 100...240 VAC supply versions and lists 120 VA power consumption with integrated 24 VDC sensor power.\u003c\/p\u003e\n\u003ch3\u003eDigital Inputs\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eHigh-Speed Inputs 0-11\u003c\/th\u003e\n\u003cth\u003eStandard Inputs 12-19\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-state Voltage\u003c\/td\u003e\n\u003ctd\u003e4.5 to 24 VDC\u003c\/td\u003e\n\u003ctd\u003e10 to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-state Voltage at 60 degC\u003c\/td\u003e\n\u003ctd\u003eUp to 26.4 VDC\u003c\/td\u003e\n\u003ctd\u003eUp to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-state Voltage at 30 degC\u003c\/td\u003e\n\u003ctd\u003eUp to 30 VDC\u003c\/td\u003e\n\u003ctd\u003eUp to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-state Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 1.5 VDC\u003c\/td\u003e\n\u003ctd\u003e0 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003eUp to 100 kHz\u003c\/td\u003e\n\u003ctd\u003eUp to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal ON Current at 24 VDC\u003c\/td\u003e\n\u003ctd\u003e9.9 mA\u003c\/td\u003e\n\u003ctd\u003e5.3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe exact input characteristics and high-speed capabilities are specified for the 1766-L32BWA family in the MicroLogix 1400 selection guide.\u003c\/p\u003e\n\u003ch3\u003eRelay Outputs\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Current per Channel\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Group Common Current\u003c\/td\u003e\n\u003ctd\u003e8 A for channels 8-11 common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn ON \/ OFF Time\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Controlled Load\u003c\/td\u003e\n\u003ctd\u003e1440 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRelay Contact Ratings\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth align=\"right\"\u003eMake Current\u003c\/th\u003e\n\u003cth align=\"right\"\u003eBreak Current\u003c\/th\u003e\n\u003cth align=\"right\"\u003eContinuous Current\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e240 VAC\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e7.5 A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.75 A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e15 A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.5 A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 VDC\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.11 A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.11 A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.22 A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.22 A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Rockwell selection guide provides these relay output ratings for the 1766-L32BWA controller group.\u003c\/p\u003e\n\u003ch3\u003eCommunication\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eSupported Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel 0\u003c\/td\u003e\n\u003ctd\u003eIsolated RS-232 \/ RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel 1\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel 2\u003c\/td\u003e\n\u003ctd\u003eNon-isolated RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus TCP\/IP\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus RTU\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDNP3\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDNP3 over IP\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDF1\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDH-485\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe MicroLogix 1400 includes three communication channels. The embedded Ethernet port supports EtherNet\/IP, Modbus TCP\/IP, and DNP3 over IP.\u003c\/p\u003e\n\u003ch3\u003eMemory and Programming\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Program Memory\u003c\/td\u003e\n\u003ctd\u003e10 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Data Memory\u003c\/td\u003e\n\u003ctd\u003e10 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Memory\u003c\/td\u003e\n\u003ctd\u003e20 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Area\u003c\/td\u003e\n\u003ctd\u003e128 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecipe Storage\u003c\/td\u003e\n\u003ctd\u003eUp to 64 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion I\/O\u003c\/td\u003e\n\u003ctd\u003eUp to 7 x 1762 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnline Editing\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eRockwell specifies 10 KB for the user program and 10 KB for user data. It also provides separate logging and recipe-storage capability.\u003c\/p\u003e\n\u003ch3\u003eMechanical Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Ventilation Clearance\u003c\/td\u003e\n\u003ctd\u003e50 mm on all sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe official MicroLogix 1400 dimensional drawing gives \u003cstrong\u003e180 x 90 x 87 mm\u003c\/strong\u003e for the controller.\u003c\/p\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the complete catalog number \u003cstrong\u003e1766-L32BWA\u003c\/strong\u003e before replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the installed unit requires the 100 to 240 VAC power configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecord the existing controller program and communication parameters before removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreserve Ethernet, RS-232, and RS-485 network settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm input commons and relay output commons before reconnecting field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify high-speed input assignments where counters or pulse-catch functions are used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRestore the RSLogix 500 project and verify firmware compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck all 20 inputs and 12 relay outputs before returning the machine to service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplacement Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMatch \u003cstrong\u003eSeries C\u003c\/strong\u003e where the installed machine requires the same hardware revision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm \u003cstrong\u003efirmware revision 21\u003c\/strong\u003e against the existing RSLogix project before replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe 1766-L32BWA does not include embedded analog I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not confuse it with the 1766-L32BWAA, which includes embedded analog channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53755776336235,"sku":"1766-L32BWA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1766-L32BWA_003_1200x1200_7ab0848d-133f-43f4-8887-e7aaef5a507c.jpg?v=1787406088"},{"product_id":"allen-bradley-1762-if4-micrologix-analog-input-module","title":"Allen-Bradley 1762-IF4 MicroLogix Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1762-IF4 is an expansion analog input module designed specifically for the MicroLogix 1200 and MicroLogix 1400 programmable logic controller (PLC) systems. This compact unit interfaces directly with process sensors to convert real-world analog signals into digital values utilized by the controller's user program. It plays a critical role in continuous process control loops, acquiring precise voltage or current measurements from transmitters, transducers, and industrial instrumentation.\u003c\/p\u003e\n\u003cp\u003eFeaturing four single-ended input channels, the 1762-IF4 utilizes a high-resolution Sigma-Delta analog-to-digital converter to deliver reliable data conversion. The module supports selectable input types including voltage (-10V to +10V, 0 to 5V, 0 to 10V) and current (4 to 20mA, 0 to 20mA). Data is accessible to the processor as raw\/proportional data or scaled-for-PID data formats, enabling seamless integration into temperature, pressure, level, and flow control loops.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour single-ended input channels configurable independently for voltage or current signals\u003c\/li\u003e\n  \u003cli\u003eAdvanced Sigma-Delta A\/D converter architecture for enhanced signal stability and noise rejection\u003c\/li\u003e\n  \u003cli\u003eSelectable data formats including raw\/proportional data and engineering units scaled for PID algorithms\u003c\/li\u003e\n  \u003cli\u003eComprehensive channel diagnostics with bit-reporting for open-circuit, over-range, and under-range conditions\u003c\/li\u003e\n  \u003cli\u003eDirect DIN rail or panel mounting for flexible physical installation within control enclosures\u003c\/li\u003e\n  \u003cli\u003eCompact 1762 expansion form factor optimizing panel space alongside MicroLogix base controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMonitoring process variables such as tank levels, line pressures, and flow rates via 4-20mA transmitters\u003c\/li\u003e\n  \u003cli\u003eReading analog temperature signals from signal conditioners in thermal regulation processes\u003c\/li\u003e\n  \u003cli\u003eProviding real-time feedback variables for closed-loop PID control loops within OEM machinery\u003c\/li\u003e\n  \u003cli\u003eAcquiring diagnostic signal data to detect sensor wire breaks or out-of-range field conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003eMicroLogix (1762)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e4 single-ended channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Ranges (Voltage)\u003c\/td\u003e\n      \u003ctd\u003e-10 to +10 VDC, 0 to 5 VDC, 0 to 10 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Ranges (Current)\u003c\/td\u003e\n      \u003ctd\u003e4 to 20 mA, 0 to 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA\/D Converter Type\u003c\/td\u003e\n      \u003ctd\u003eSigma-Delta\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e12 bits (plus sign)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Impedance (Voltage Terminal)\u003c\/td\u003e\n      \u003ctd\u003e200 kOhm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Impedance (Current Terminal)\u003c\/td\u003e\n      \u003ctd\u003e275 kOhm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Current Draw (5 VDC)\u003c\/td\u003e\n      \u003ctd\u003e50 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Current Draw (24 VDC)\u003c\/td\u003e\n      \u003ctd\u003e35 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-20 to 65 degC (-4 to 149 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Type\u003c\/td\u003e\n      \u003ctd\u003eOpen style\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cdiv\u003eStandard industrial agency certifications including c-UL-us, CE, and C-Tick for compliant global deployment.\u003c\/div\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53770291675499,"sku":"1762-IF4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1762-IF4_1200x1200_fa1a8548-2477-4163-91be-51c8047e6543.jpg?v=1787740481"},{"product_id":"allen-bradley-1762-ow16-micrologix-16-point-relay-output-expansion-module","title":"Allen-Bradley 1762-OW16 MicroLogix 16-Point Relay Output Expansion Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1762-OW16 is a high-density relay output expansion module designed to extend the discrete control capabilities of MicroLogix 1100, 1200, and 1400 programmable logic controllers. As an essential part of the 1762 expansion I\/O platform, this unit interfaces the controller CPU with heavy-duty industrial loads, providing reliable switching for both AC and DC control circuits. It translates low-voltage digital commands from the controller processor into high-capacity switching actions for actuators, motor starters, indicator lamps, and control valves within automated industrial systems.\u003c\/p\u003e\n\u003cp\u003eArchitecturally engineered for seamless DIN rail or panel mounting, the 1762-OW16 connects directly via the integral bus connector to the base controller or preceding expansion module. The module features sixteen discrete output points organized into two isolated common groups, allowing multi-voltage control capability across a single hardware footprint. Surge suppression is strongly recommended across all inductive loads to maximize contact life and protect against high-voltage transient spikes during de-energization cycles.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 relay output channels providing versatile switching for AC and DC industrial loads\u003c\/li\u003e\n  \u003cli\u003eTwo isolated common groups (Outputs 0-7 and Outputs 8-15) for multi-voltage application flexibility\u003c\/li\u003e\n  \u003cli\u003eMaximum continuous current rating of 2.5A per point and 8.0A per common group\u003c\/li\u003e\n  \u003cli\u003eDirect bus interface connection to MicroLogix 1100, 1200, and 1400 controllers without requiring a separate power supply\u003c\/li\u003e\n  \u003cli\u003eRemovable terminal blocks featuring secure screw connections for simplified field wiring maintenance\u003c\/li\u003e\n  \u003cli\u003eCompact modular form factor supporting DIN rail or direct panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInterface control between MicroLogix controllers and high-current actuators or motor starters\u003c\/li\u003e\n  \u003cli\u003eMulti-voltage discrete load switching in manufacturing machinery and material handling systems\u003c\/li\u003e\n  \u003cli\u003eExpansion of discrete control points for remote equipment skids and packaging lines\u003c\/li\u003e\n  \u003cli\u003eIsolated zone output switching for safety interlocks and auxiliary alarm circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBrand\u003c\/td\u003e\n      \u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number\u003c\/td\u003e\n      \u003ctd\u003e1762-OW16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eRelay Output Expansion Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e16 points (Form A, N.O.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Current Draw (Max)\u003c\/td\u003e\n      \u003ctd\u003e180 mA at 5 VDC; 80 mA at 24 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eContinuous Current per Point\u003c\/td\u003e\n      \u003ctd\u003e2.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eContinuous Current per Common\u003c\/td\u003e\n      \u003ctd\u003e8.0 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax Module Current\u003c\/td\u003e\n      \u003ctd\u003e16.0 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e5 to 265 VAC \/ 5 to 125 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eON\/OFF Response Time\u003c\/td\u003e\n      \u003ctd\u003e10 ms max\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n      \u003ctd\u003e6 (Maximum expansion modules from power supply)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTerminal Type\u003c\/td\u003e\n      \u003ctd\u003eScrew Terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eDIN Rail or Panel Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC (32 to 131 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ec-UL-us Listed Industrial Control Equipment\u003c\/li\u003e\n  \u003cli\u003eCE Compliant for applicable directives\u003c\/li\u003e\n  \u003cli\u003eC-Tick compliant for Australian market\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53770293936491,"sku":"1762-OW16","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1762-OW16_1200x1200_8ac50c72-b08b-4252-99e5-04722f0fd2df.jpg?v=1787740513"},{"product_id":"allen-bradley-1762-ob8-micrologix-1200-solid-state-digital-dc-output-module","title":"Allen-Bradley 1762-OB8 MicroLogix 1200 Solid-State Digital DC Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1762-OB8\u003c\/strong\u003e is an 8-point sourcing 24V DC solid-state digital output expansion module designed for the MicroLogix 1200 programmable logic controller system. It expands the discrete output capability of the controller, allowing direct switching of solid-state DC loads in industrial automation, process control, and machine control applications.\u003c\/p\u003e\n\u003cp\u003eThe module operates on a 24V DC nominal field supply (5 to 265V AC or 5 to 125V DC operating voltage range) and interfaces directly with the controller through the expansion bus. Featuring transistor-based solid-state outputs, the \u003cstrong\u003e1762-OB8\u003c\/strong\u003e provides high-speed switching capability with maximum signal delays of 0.1 ms for turn-on and 1.0 ms for turn-off. Its rugged open-style enclosure withstands up to 30G operational shock and 5G vibration at 500 Hz, making it suitable for demanding industrial control environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 Sourcing Solid-State Outputs:\u003c\/strong\u003e Provides 8 channels of 24V DC sourcing output points for driving DC loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Signal Response:\u003c\/strong\u003e Achieves a maximum turn-on signal delay of 0.1 ms and a turn-off delay of 1.0 ms under resistive loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Thermal Current Capacity:\u003c\/strong\u003e Supports up to 1.0A continuous current per point and 8.0A per module at 86 degF (30 degC), transitioning to 0.5A per point and 4.0A per module at 131 degF (55 degC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Status Indicators:\u003c\/strong\u003e Equipped with 1 green health indicator and 4 red error indicators for real-time status display and module diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Power Draw:\u003c\/strong\u003e Draws a maximum bus current of 115 mA at 5V DC (0.575W) from the MicroLogix bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Mechanical Design:\u003c\/strong\u003e Rated for 30G operational shock and 5G vibration at 500 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControlling 24V DC solenoids, pilot lights, small DC motor starters, and auxiliary relays.\u003c\/li\u003e\n\u003cli\u003eHigh-speed pulse signaling and discrete control loops requiring microsecond-level turn-on response times.\u003c\/li\u003e\n\u003cli\u003eDiscrete load expansion for MicroLogix 1200 controller platforms across packaging, material handling, and automated assembly systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1762-OB8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSolid-State Digital DC Output Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controller\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e1 Green Health Indicator, 4 Red Error Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5...265V AC \/ 5...125V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Bus Current Draw\u003c\/td\u003e\n\u003ctd\u003e115 mA @ 5V DC (0.575W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Continuous Current Per Point\u003c\/td\u003e\n\u003ctd\u003e1.0A @ 86 degF (30 degC) \/ 0.5A @ 131 degF (55 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Continuous Current Per Module\u003c\/td\u003e\n\u003ctd\u003e8.0A @ 86 degF (30 degC) \/ 4.0A @ 131 degF (55 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Off-State Leakage\u003c\/td\u003e\n\u003ctd\u003e1.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin On-State Current\u003c\/td\u003e\n\u003ctd\u003e1.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax On-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.0V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePerformance \u0026amp; Environmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Signal Delay (Resistive Load)\u003c\/td\u003e\n\u003ctd\u003eON: 0.1 ms \/ OFF: 1.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e5G @ 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, cUL, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect main power to the MicroLogix controller system and external I\/O circuits before installing or removing modules.\u003c\/li\u003e\n\u003cli\u003eMount the module horizontally on a standard 35 mm DIN rail or panel surface, maintaining at least 50 mm (2 in.) of clearance on all sides for convective cooling.\u003c\/li\u003e\n\u003cli\u003eAttach the expansion ribbon cable securely to the adjacent controller or 1762 I\/O module bus connector, verifying proper bus latch seating.\u003c\/li\u003e\n\u003cli\u003eRoute 24V DC output power and load wiring separately from AC line power and high-voltage motor conductors to minimize electrical noise.\u003c\/li\u003e\n\u003cli\u003eWire external surge suppression diodes (such as 1N4004) directly across inductive DC loads to protect solid-state output circuits from switching voltage transients.\u003c\/li\u003e\n\u003cli\u003eRemove the protective debris shield from the top of the module after panel drilling and wiring are complete to prevent thermal buildup.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53770298360171,"sku":"1762-OB8","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1762-OB8_001_1200x1200_8f0b0539-127b-448c-a971-2e56771a3e41.jpg?v=1787744735"},{"product_id":"allen-bradley-1762-iq8-micrologix-dc-discrete-input-module","title":"Allen-Bradley 1762-IQ8 MicroLogix DC Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1762-IQ8 is a reliable DC discrete input module designed to expand the input capabilities of MicroLogix 1100, 1200, 1400, and 1500 programmable logic controllers. Serving as a single-slot expansion unit, this module integrates seamlessly into your automation system to monitor discrete field signals in various industrial control architectures. Built to deliver consistent performance, it features robust optical isolation and accommodates standard 24VDC sensor inputs.\u003c\/p\u003e\n\u003cp\u003eEngineered for industrial environments, the 1762-IQ8 supports both DIN rail and direct panel mounting configurations to accommodate cabinet layout requirements. It is well-suited for discrete monitoring tasks in manufacturing plants, packaging machinery, material handling systems, and general machine automation where reliable digital signal acquisition is critical.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides 8 sinking\/sourcing (IEC Type 1 compatible) DC input channels\u003c\/li\u003e\n  \u003cli\u003eCompatible with MicroLogix 1100, 1200, 1400, and 1500 programmable controllers\u003c\/li\u003e\n  \u003cli\u003eSupports flexible DIN rail or direct panel mounting options\u003c\/li\u003e\n  \u003cli\u003eEquipped with removable terminal blocks for easier wiring and maintenance\u003c\/li\u003e\n  \u003cli\u003eOptical isolation between the I\/O terminals and the controller backplane\u003c\/li\u003e\n  \u003cli\u003eStatus indicators (LED) for clear visual confirmation of individual input states\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete signal monitoring for automated assembly lines\u003c\/li\u003e\n  \u003cli\u003eSensor and limit switch data acquisition in packaging machinery\u003c\/li\u003e\n  \u003cli\u003eConveyor system status tracking in material handling\u003c\/li\u003e\n  \u003cli\u003eGeneral machine control and discrete automation panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003e1762-IQ8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eMicroLogix DC Discrete Input Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8 inputs (sinking\/sourcing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e10 to 30VDC at 30 degC (86 degF); 10 to 26.4VDC at 55 degC (131 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n      \u003ctd\u003e10VDC min.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOn-State Current\u003c\/td\u003e\n      \u003ctd\u003e2.0mA min. at 10VDC; 8.0mA nominal at 24VDC; 12.0mA max. at 30VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n      \u003ctd\u003e5VDC max.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOff-State Current\u003c\/td\u003e\n      \u003ctd\u003e1.5mA max.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Impedance\u003c\/td\u003e\n      \u003ctd\u003e3 kOhms nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Delay (On \/ Off)\u003c\/td\u003e\n      \u003ctd\u003e8.0ms nominal ON \/ 8.0ms nominal OFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Current Draw (5VDC)\u003c\/td\u003e\n      \u003ctd\u003e50mA max.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Heat Dissipation\u003c\/td\u003e\n      \u003ctd\u003e3.7W max.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003eDIN Rail or Panel Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe module features a removable screw-clamp terminal block located on the front, allowing field wiring to be connected or disconnected easily without disturbing the module housing. Channel status LEDs provide immediate feedback on active inputs, while the integrated bus connector links the module directly to the base controller or preceding expansion I\/O module.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the module securely on a EN 50022 DIN rail or directly to a panel using mounting screws.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum installation clearance of 2 inches (50 mm) on all sides of the module to ensure proper airflow and ventilation.\u003c\/li\u003e\n  \u003cli\u003eEnsure the host controller power is turned off before connecting or disconnecting expansion modules.\u003c\/li\u003e\n  \u003cli\u003eUse appropriate wire sizing (typically 22 to 14 AWG) for secure connections to the removable terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53770301702507,"sku":"1762-IQ8","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1762-IQ8_1200x1200_8ef4d325-2911-4e7f-8598-7e6db8b4cc80.jpg?v=1787740728"},{"product_id":"allen-bradley-1761-net-dni-slc-500-devicenet-interface-controller","title":"Allen-Bradley 1761-NET-DNI SLC 500 DeviceNet Interface Controller","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1761-NET-DNI connects DF1 serial devices to a DeviceNet network.\u003c\/p\u003e\n\u003cp\u003eThe Series B information on this page covers explicit messaging, input and output split points, local RS-232 configuration, EDS file selection, and DF1 substitution addressing.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDF1-to-DeviceNet Protocol Conversion:\u003c\/strong\u003e Enables DF1 serial devices, including MicroLogix and SLC 500 controllers, to integrate directly into DeviceNet industrial networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplicit Messaging Capability:\u003c\/strong\u003e Series B functionality allows the module to initiate explicit messages across DeviceNet and accept messages to explicit assemblies at any time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Data Split Points:\u003c\/strong\u003e Incorporates user-defined Input Split Point and Output Split Point parameters to flexibly balance memory usage between Master\/Slave cyclic I\/O and explicit messaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal RS-232 Configuration:\u003c\/strong\u003e Supports direct parameter configuration via the RS-232 serial port using the dedicated DNI Configuration Software Utility, eliminating the need for network interface converters during standalone setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDF1 Substitution Address:\u003c\/strong\u003e Features a dedicated substitution parameter that allows DF1 devices, such as MicroView terminals, to transparently route messages to Allen-Bradley controllers across the network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Operating Control:\u003c\/strong\u003e Replaces legacy Standby\/Operational parameters with an I\/O Scan Enable control parameter within the Electronic Data Sheet (EDS) for streamlined network management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eMicroLogix \/ SLC 500 Network Interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1761-NET-DNI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Series\u003c\/td\u003e\n\u003ctd\u003eSeries B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Interface Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Protocol\u003c\/td\u003e\n\u003ctd\u003eDF1 Full-Duplex \/ DF1 Half-Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software Compatibility\u003c\/td\u003e\n\u003ctd\u003eRSNetWorx for DeviceNet (v2.11.36 or higher), DNI Configuration Utility (DNI_UTIL_B.EXE v2.001 or higher)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired EDS Files\u003c\/td\u003e\n\u003ctd\u003e1761DNI3.EDS (FRN 2.02 or lower), 1761DNI4.EDS (FRN 2.03 or higher)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplicit Messaging\u003c\/td\u003e\n\u003ctd\u003eSupported (Initiation and Reception)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Port\u003c\/td\u003e\n\u003ctd\u003eRS-232 Serial Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePort \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-232 Port\u003c\/td\u003e\n\u003ctd\u003eConnects to host PLC serial port or configuration PC using DF1 protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviceNet Connector\u003c\/td\u003e\n\u003ctd\u003e5-pin open style connector for trunkline\/dropline network connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConfiguration Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEDS File Installation:\u003c\/strong\u003e Ensure the correct Electronic Data Sheet (1761DNI3.EDS for FRN $\\le 2.02$ or 1761DNI4.EDS for FRN $\\ge 2.03$) is registered in RSNetWorx for DeviceNet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Serial Setup:\u003c\/strong\u003e Use the DNI Configuration Software Utility (DNI_UTIL_B.EXE) via the RS-232 serial port to set node addresses, baud rates, and serial port parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit Point Allocation:\u003c\/strong\u003e Define the Input Split Point and Output Split Point parameters to allocate data buffer sizes between Master\/Slave I\/O and explicit messaging assemblies according to system requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDF1 Substitution Address Setup:\u003c\/strong\u003e If connecting a serial HMI or MicroView, configure the DF1 Substitution Address parameter to map incoming serial requests to target controller addresses on DeviceNet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries A Migration Note:\u003c\/strong\u003e Note that Series A configuration files are not directly compatible with Series B hardware; parameters must be manually re-entered into the Series B device due to enhanced messaging architecture.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53770304717163,"sku":"1761-NET-DNI","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1761-NET-DNI_001_1200x1200_37d182cb-f18b-405e-91df-5222acf90877.png?v=1788446337"},{"product_id":"allen-bradley-1761-l32bwb-micrologix-1000-controller-processor","title":"Allen-Bradley 1761-L32BWB MicroLogix 1000 Controller Processor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1761-L32BWB is a compact and reliable MicroLogix 1000 programmable controller designed to handle small-scale automation applications and standalone machinery. Featuring an integrated power supply, embedded I\/O channels, memory, and a communication interface, this controller delivers essential processing performance in a space-saving footprint. It supports both DIN rail and panel mounting options for installation flexibility within industrial control panels.\u003c\/p\u003e\n\u003cp\u003eEquipped with DC inputs and relay outputs, the 1761-L32BWB facilitates seamless integration with operator interfaces, SCADA software, and programming terminals. Its built-in RS-232 communication port supports the DF1 protocol for efficient program uploading, downloading, and online monitoring, and it can interface with a 1761-NET-AIC module for connection to a DH-485 network.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCompact all-in-one design incorporating controller, power supply, and I\/O channels\u003c\/li\u003e\n  \u003cli\u003eEmbedded RS-232 communication port supporting DF1 full-duplex, half-duplex slave, and radio modem protocols\u003c\/li\u003e\n  \u003cli\u003eIncludes 20 digital DC inputs, including one high-speed input, and 12 relay outputs\u003c\/li\u003e\n  \u003cli\u003eNon-volatile EEPROM memory for reliable user program and data retention without requiring a battery\u003c\/li\u003e\n  \u003cli\u003eMaster Control Relay (MCR) output for enhanced system safety and machine shutdown control\u003c\/li\u003e\n  \u003cli\u003eFlexible mounting capabilities supporting horizontal or vertical DIN rail and panel mount configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eStandalone industrial machinery and OEM equipment control\u003c\/li\u003e\n  \u003cli\u003eSmall-scale conveyor systems and material handling\u003c\/li\u003e\n  \u003cli\u003eHVAC equipment automation\u003c\/li\u003e\n  \u003cli\u003ePump and compressor monitoring\u003c\/li\u003e\n  \u003cli\u003eLighting and environmental control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBrand\u003c\/td\u003e\n      \u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ SKU\u003c\/td\u003e\n      \u003ctd\u003e1761-L32BWB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eMicroLogix 1000 Programmable Controller Processor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eController Series\u003c\/td\u003e\n      \u003ctd\u003eMicroLogix 1000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLine Voltage \/ Power Supply\u003c\/td\u003e\n      \u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Type \/ Range\u003c\/td\u003e\n      \u003ctd\u003e24 VDC (14 to 30 VDC sink\/source)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs\u003c\/td\u003e\n      \u003ctd\u003e20 inputs (including 1 high-speed input)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Outputs\u003c\/td\u003e\n      \u003ctd\u003e12 relay outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Port\u003c\/td\u003e\n      \u003ctd\u003e1 x RS-232 8-pin mini-DIN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMemory Capacity\u003c\/td\u003e\n      \u003ctd\u003e1K words (EEPROM)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd\u003e7 W max.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-20 to 55 degC (-4 to 131 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd\u003eOpen Type (IP20)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe 1761-L32BWB features removable terminal blocks for convenient field wiring of power, inputs, and outputs without disturbing existing cable routing. The 8-pin mini-DIN RS-232 port connects directly to programming PCs using standard communication cables or interfaces with industrial networks via network adapter modules.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the controller securely on a standard 35mm DIN rail or directly to a panel using mounting screws. Ensure a minimum clearance of 2 inches (51 mm) is maintained on all sides of the unit to allow adequate airflow and heat dissipation, regardless of whether the unit is mounted horizontally or vertically. Verify that power supply voltages are within specified operating limits prior to energizing the system.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53770306060651,"sku":"1761-L32BWB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1761-L32BWB_1200x1200_b9f439f1-e467-406d-933b-6afe7a8d2686.jpg?v=1787740831"},{"product_id":"allen-bradley-1762-iq16-micrologix-discrete-dc-input-module","title":"Allen-Bradley 1762-IQ16 MicroLogix Discrete DC Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAllen-Bradley 1762-IQ16\u003c\/strong\u003e is a 16-input, 24 V DC sink\/source module for MicroLogix 1100, 1200 and 1400 controllers.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSixteen sink\/source DC inputs\u003c\/li\u003e\n\u003cli\u003e10–30 V DC operating range\u003c\/li\u003e\n\u003cli\u003e8 ms default input delay\u003c\/li\u003e\n\u003cli\u003eRemovable front terminal block\u003c\/li\u003e\n\u003cli\u003eDIN-rail or panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ SKU\u003c\/td\u003e\n      \u003ctd\u003e1762-IQ16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eDiscrete DC Input Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCompatible Controller Series\u003c\/td\u003e\n      \u003ctd\u003eMicroLogix 1100, MicroLogix 1200, MicroLogix 1400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e16 inputs (sinking\/sourcing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVoltage Category\u003c\/td\u003e\n      \u003ctd\u003e24V DC Sink\/Source\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e10 to 30V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOn-State Voltage (Min)\u003c\/td\u003e\n      \u003ctd\u003e10V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOn-State Current (Nominal)\u003c\/td\u003e\n      \u003ctd\u003e8.0mA @ 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOff-State Voltage (Max)\u003c\/td\u003e\n      \u003ctd\u003e5V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOff-State Current (Max)\u003c\/td\u003e\n      \u003ctd\u003e1.5mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Delay (On to Off \/ Off to On)\u003c\/td\u003e\n      \u003ctd\u003e8.0ms default (configurable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe module features removable front terminal blocks protected by a hinged, finger-safe cover to facilitate secure wiring without exposing live terminals. Terminal connections accommodate standard industrial copper wire sizes. Bus connector interface on the side of the module provides power and communication linkage directly to the base controller or adjacent expansion modules.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53770310287723,"sku":"1762-IQ16","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1762-IQ16_1200x1200_9a30260e-9959-4056-9e6c-b0329c58d36e.jpg?v=1787740993"}],"url":"https:\/\/www.plcprotech.com\/collections\/allen-bradley-micrologix.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}