{"title":"Bently Nevada 3300 NSv Proximitor Sensor","description":"\u003cp\u003eThe Bently Nevada 3300 NSv Proximitor Sensor is the electronic heart of the NSv transducer system, engineered specifically for confined mounting scenarios. Its architecture is designed to drive \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-nsv-proximity-probes\"\u003e3300 NSv proximity probes\u003c\/a\u003e through specialized \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-nsv-extension-cable\"\u003eNSv extension cables\u003c\/a\u003e. Technical characteristics include a unique linear range optimized for smaller targets and the ability to operate effectively with narrow shaft diameters. Functionally, this sensor converts the impedance changes in the probe tip into a proportional voltage signal, specialized for detecting shaft vibration and position in tight spaces. It offers the same high reliability as the standard 3300 XL series but with electronic tuning that accounts for the smaller physical dimensions of the NSv probe, ensuring precision in air compressors and high-speed pumps.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-330980-70-00-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-70-00 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e330980-70-00\u003c\/strong\u003e is a high-performance proximity sensor designed as a core component of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This sensor is specifically engineered for critical machinery applications with tight installation constraints , including centrifugal air compressors, refrigeration compressors, and process gas compressors. The \u003cstrong\u003e330980-70-00\u003c\/strong\u003e accepts input from a non-contacting 3300 RAM or 3300 NSv proximity probe and an associated extension cable , generating a continuous analog voltage output proportional to the gap distance between the probe tip and the target. With an Average Scale Factor (ASF) of 7.87 V\/mm (200 mV\/mil) , it provides accurate data for radial vibration, axial position, tachometer speed, and phase reference measurements on fluid-filmed bearing machines. Its thin, space-saving mechanical housing accommodates high-density multi-channel monitoring system layouts with complete RFI\/EMI protection.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeamless system compatibility, accepting one non-contacting 3300 RAM or 3300 NSv proximity probe and extension cable.\u003c\/li\u003e\n\u003cli\u003eHigh-density panel mount base designed for secure integration into standard monitoring configurations.\u003c\/li\u003e\n\u003cli\u003eAdvanced RFI\/EMI immunity ensuring full European CE mark compliance and preventing radio frequency interference without dedicated shielding enclosures.\u003c\/li\u003e\n\u003cli\u003eSpringLoc terminal strips requiring no special tools, providing reliable and gas-tight field wiring connections.\u003c\/li\u003e\n\u003cli\u003eRobust internal circuitry protected against electrostatic discharge (ESD) during handling and operation.\u003c\/li\u003e\n\u003cli\u003eDefault factory calibration to AISI 4140 steel, maintaining high accuracy and linear interchangeability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration and radial position monitoring on centrifugal and process gas compressors.\u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements in tight-space machinery installations.\u003c\/li\u003e\n\u003cli\u003eTachometer, zero-speed, and Keyphasor phase reference signal generation.\u003c\/li\u003e\n\u003cli\u003eUpgrades and retrofits for legacy 3300 RAM, 3000-series, and 7000-series 190 transducer installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330980-70-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximitor Sensor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-70\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Length and Mounting Option: 7.0 meters (23.0 feet) system length, panel mount \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: Not required \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries \/ System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Acceptance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne non-contacting 3300 RAM or 3300 NSv proximity probe and extension cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers; -23 Vdc to -26 Vdc with barriers \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum consumption \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils) total; begins at approx. 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over ambient range \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) field wiring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) [0.25 to 0.75 mm2 (18 to 23 AWG) with ferrules] \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) maximum between sensor and monitor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass ClickLoc connectors \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 grams (9 ounces) typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Block \/ Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Input (-24 Vdc nominal) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Signal Output (Voltage proportional to gap) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon \/ Circuit Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput connection from 3300 NSv Extension Cable (ClickLoc type) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e This specific model (\u003cstrong\u003e-70\u003c\/strong\u003e) is supplied with a panel-mount base configuration. Secure the housing flat onto the structural panel layout using recommended mounting screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Connection:\u003c\/strong\u003e Utilize the tool-less SpringLoc terminal strips by inserting stripped conductor leads (16 to 24 AWG) directly into the clamping mechanism to secure field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Matching:\u003c\/strong\u003e Ensure that the combined physical length of the selected proximity probe and extension cable precisely equals the 7.0-meter system tuning length of the sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD):\u003c\/strong\u003e Apply proper ESD ground straps and precautions when touching the terminals or coaxial input port during installation to prevent inner circuit component degradation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666743751019,"sku":"330980-70-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-70-00-nsv-proximity-sensor-dgaaoqm1s0g_4fb30580-5cb3-4bae-9010-2ca327f5d798.jpg?v=1765446933"},{"product_id":"bently-nevada-330980-51-05-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-51-05 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-51-05\u003c\/strong\u003e is a non-contacting \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e designed as an integral component of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This system is specifically developed for machinery with tight installation constraints or restricted target sizes, such as centrifugal air compressors, refrigeration compressors, and process gas compressors. It excels in applications where counterbore, sideview, or rearview limitations restrict the deployment of standard 5 mm and 8 mm transducer variants. The \u003cstrong\u003e330980-51-05\u003c\/strong\u003e processes input signals to provide precise radial vibration, radial position, axial position, tachometer, and phase reference (Keyphasor) monitoring on fluid-filmed bearing machinery.\u003c\/p\u003e\n\u003cp\u003eEngineered with a compact and thin physical footprint, this \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e is factory configured for high-density 35 mm DIN-rail mounting structures to minimize required enclosure space. It features an Incremental Scale Factor (ISF) of 7.87 V\/mm (200 mV\/mil) over a 1.5 mm (60 mils) linear range. Equipped with integrated SpringLoc terminal strips, the unit facilitates robust and rapid field connections without needing specialized insertion tools. Additionally, advanced RFI\/EMI immunity enables the device to satisfy European CE requirements without requiring specialized shielding or isolated mounting setups.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimizes non-contacting measurement performance for confined machinery spaces and small shaft diameters.\u003c\/li\u003e\n\u003cli\u003eThin mechanical profile enables efficient high-density installations on standard 35 mm DIN rails.\u003c\/li\u003e\n\u003cli\u003eBuilt-in SpringLoc terminal strips provide reliable, vibration-resistant electrical connections without special tooling.\u003c\/li\u003e\n\u003cli\u003eHigh RFI\/EMI resistance prevents surrounding high-frequency radio signals from degrading the transducer measurement integrity.\u003c\/li\u003e\n\u003cli\u003eInternal protection circuitry guards sensitive terminal and connector paths against damage from electrostatic discharge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eRefrigeration compressors\u003c\/li\u003e\n\u003cli\u003eProcess gas compressors\u003c\/li\u003e\n\u003cli\u003eRadial vibration and axial position tracking on small-diameter shafts (under 51 mm)\u003c\/li\u003e\n\u003cli\u003ePhase reference (Keyphasor) and zero-speed tachometer signal monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 31.7534%;\"\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 14.5098%;\"\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 53.2027%;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.7534%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.5098%;\"\u003e330980\u003c\/td\u003e\n\u003ctd style=\"width: 53.2027%;\"\u003e3300 XL NSv Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.7534%;\"\u003e\u003cstrong\u003eAA (Total Length \u0026amp; Mounting)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.5098%;\"\u003e51\u003c\/td\u003e\n\u003ctd style=\"width: 53.2027%;\"\u003e5.0 metre (16.4 feet) system length, DIN mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.7534%;\"\u003e\u003cstrong\u003eBB (Agency Approval)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.5098%;\"\u003e05\u003c\/td\u003e\n\u003ctd style=\"width: 53.2027%;\"\u003eCSA, ATEX, IECEx Zone 0\/1, Baseline Class I, Zone 0\/1, Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Input Configuration\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Voltage Requirements\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers), 12 mA maximum current; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupply Voltage Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils); begins at approx. 0.25 mm (10 mils) from the target surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over linear range including interchangeability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than plus\/minus 0.06 mm (plus\/minus 2.3 mils) over linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWiring Termination\u003c\/td\u003e\n\u003ctd\u003eIntegrated SpringLoc terminal strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e8.13 cm x 6.12 cm x 6.35 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNet Weight (Typical)\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity Range\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (Tested to IEC 68-2-3 damp heat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Mount securely onto a standard 35 mm DIN rail using the integrated high-density mounting base. Ensure a minimum clearance of 3.05 mm is available to facilitate smooth rail engagement and removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Connections:\u003c\/strong\u003e Insert stripped field wires into the SpringLoc terminals. Supported wire cross-sections range from 0.2 to 1.5 mm2 (16 to 24 AWG), or 0.25 to 0.75 mm2 (18 to 23 AWG) if using wire ferrules. A three-conductor shielded triad cable is recommended.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Distance Limit:\u003c\/strong\u003e The maximum permissible cable distance between the Proximitor Sensor and the monitoring rack must not exceed 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Ensure the sensor body is mechanically isolated from the enclosure ground using appropriate non-conductive components to prevent common-mode noise and ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e Complies with European Community Directive 2014\/30\/EU, EN 61000-6-2 (Industrial Immunity), and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Certified to CSA, ATEX, and IECEx standards for Zone 0\/1, Div 1 intrinsically safe installations under option code 05.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666758693227,"sku":"330980-51-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-51-05-proximity-sensor-ldi15pzeysx_72df144a-4f50-41b4-8f77-e811785b6031.jpg?v=1765447085"},{"product_id":"bently-nevada-330980-50-00-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-50-00 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-50-00\u003c\/strong\u003e is a non-contacting proximity sensor designed for use within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This sensor is engineered for machines with tight installation requirements, such as centrifugal air compressors, refrigeration compressors, and process gas compressors, where counter bore, sideview, or rearview restrictions limit the use of standard transducer systems. The \u003cstrong\u003e330980-50-00\u003c\/strong\u003e functions by outputting an Average Scale Factor of 7.87 V\/mm (200 mV\/mil), which is ideal for small target applications such as measuring radial vibration on shafts smaller than 51 mm or axial position on flat targets smaller than 15 mm.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e features a thin design optimized for traditional panel mount configurations. It provides advanced RFI\/EMI immunity that prevents nearby high-frequency radio signals from adversely affecting the transducer system, enabling it to achieve European CE mark approvals without specialized mounting considerations. Additionally, the device is equipped with SpringLoc terminal strips that require no special installation tools, facilitating robust and fast field wiring connections.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for space-restricted industrial applications with a thin and compact panel-mount design.\u003c\/li\u003e\n\u003cli\u003eFeatures an integrated SpringLoc terminal strip to accelerate field installation and maximize wiring robustness without special tools.\u003c\/li\u003e\n\u003cli\u003eProvides high RFI\/EMI immunity to resist electromagnetic noise from nearby high-frequency radio devices.\u003c\/li\u003e\n\u003cli\u003eProtects internal transducer electronics against electrostatic discharge at the terminals and connector interfaces.\u003c\/li\u003e\n\u003cli\u003eCapable of driving direct replacements for legacy 3300 RAM and 3000-series or 7000-series 190 Transducer Systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors \u003c\/li\u003e\n\u003cli\u003eRefrigeration compressors \u003c\/li\u003e\n\u003cli\u003eProcess gas compressors \u003c\/li\u003e\n\u003cli\u003eRadial vibration and radial position measurements on small-diameter shafts \u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements on small flat targets \u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed, and Phase reference (Keyphasor) signal monitoring \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980\u003c\/td\u003e\n\u003ctd\u003eNSv Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal length and mounting option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 metre (16.4 feet) system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency approval option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Input\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupply Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), beginning at approximately 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% including interchangeability error \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTerminal Interface\u003c\/td\u003e\n\u003ctd\u003eSpringLoc terminal strips \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNet Weight (typical)\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (Tested to IEC 68-2-3 damp heat) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Secure the device into the designated housing or junction box plate using the integrated panel-mount base orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Connect field wiring using 0.2 to 1.5 mm2 (16 to 24 AWG) conductors, or 0.25 to 0.75 mm2 (18 to 23 AWG) if using ferrules. A three-conductor shielded triad cable is recommended.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Length:\u003c\/strong\u003e Ensure the total distance between the Proximitor Sensor and the associated monitor does not exceed 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Prevention:\u003c\/strong\u003e While terminal and connector tracks include internal protection circuits, use an ESD wrist strap and standard grounding practices during handling and field terminal wire connections to avoid electrostatic discharge damage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666846511467,"sku":"330980-50-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-50-00-nsv-proximitor-sensor-mkqkniffh3n_2c8deaf5-adf3-4ef9-88be-ef6c2eabde61.jpg?v=1765448933"},{"product_id":"bently-nevada-330980-71-00-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-71-00 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330980-71-00\u003c\/strong\u003e is a non-contacting \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e designed as part of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. It is specifically engineered for use with centrifugal air compressors, refrigeration compressors, process gas compressors, and other machinery exhibiting tight installation requirements or small target areas. This includes measuring radial vibration or radial position on shafts smaller than 51 mm (2 inches) and axial position on flat targets smaller than 15 mm (0.6 inches).\u003c\/p\u003e\n\u003cp\u003eThe device features an enhanced side-view profile and small target characteristics that deliver a 1.5 mm (60 mils) linear range. Utilizing SpringLoc terminal strips, it allows robust field wiring connections without requiring specialized installation tools. Its compact mechanical profile supports high-density installations while providing immunity against RFI\/EMI high-frequency radio signals.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePart of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e optimizing performance for tight installation constraints.\u003c\/li\u003e\n\u003cli\u003eCompact design allows mounting in either high-density DIN-rail installations or traditional panel mount configurations.\u003c\/li\u003e\n\u003cli\u003eIntegrates SpringLoc terminal strips to enable fast, secure field wiring without specialized installation tools.\u003c\/li\u003e\n\u003cli\u003eEnhanced RFI\/EMI immunity protects the transducer system from nearby high-frequency radio signal interference.\u003c\/li\u003e\n\u003cli\u003eDefault factory calibration to AISI 4140 steel, with alternative material calibrations available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors, refrigeration compressors, and process gas compressors.\u003c\/li\u003e\n\u003cli\u003eRadial vibration and radial position measurements on fluid-filmed bearing machines with small shafts.\u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements on small or restricted flat targets.\u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed measurements, and phase reference (Keyphasor signals).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330980-71-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet) system length, DIN mount, Agency Approval: Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption (-23 Vdc to -26 Vdc with barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over the 1.5 mm linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils) starting at approx. 0.25 mm (10 mils) from target (0.25 to 1.75 mm \/ 10 to 70 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than plus\/minus 0.06 mm (plus\/minus 2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) [0.25 to 0.75 mm2 (18 to 23 AWG) with ferrules]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Field Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1000 feet) between Proximitor Sensor and monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Weight (Typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (Tested to IEC 68-2-3 damp heat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Designed for 35mm DIN rail mounting installations. Ensure a minimum additional clearance of 3.05 mm (0.120 inches) is available to remove the DIN rail smoothly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Use a three-conductor shielded triad cable between the sensor and the monitor up to a maximum length of 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge:\u003c\/strong\u003e Take reasonable engineering precautions to avoid electrostatic discharge during handling and electrical connection hookup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Ensure the proper mounting pads are utilized to isolate the sensor body from the housing ground environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions) for Industrial Environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 (HFT = 0), SIL 3 (HFT = 1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e 2019 Rules for Conditions of Classification (Part 1, 1-1-1\/7.7, 1-1-A3, 1-1-A4) and Part 1 Offshore Units and Structures (1-1-4\/9.7, 1-1-A2, 1-1-A3).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848969067,"sku":"330980-71-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-71-00-nsv-proximitor-sensor-ve42ucabr4j_6166de64-f722-486c-802a-f17976637fcc.jpg?v=1765449002"},{"product_id":"bently-nevada-330980-50-05-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-50-05 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eSystem \u0026amp; Engineering Context\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330980-50-05\u003c\/strong\u003e is a high-stability, active radio-frequency (RF) signal conditioning module designed as the core processing engine of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. The NSv (Narrow Side-view) sub-series is specifically deployed on fluid-filmed bearing assets where tight installation clearances, micro-diameter shafts (less than 51 mm \/ 2 in), or tight counterbores restrict the usage of standard 5mm and 8mm probes.\u003c\/p\u003e\n\u003cp\u003eThe primary electrical role of this Proximitor Sensor is to provide the high-frequency excitation carrier loop to a non-contacting 3300 NSv probe via a 75-ohm extension cable. It reads the raw modulation of the RF field caused by shaft eddy currents and converts these micro-gap fluctuations into a clean, linear, and continuous voltage output. This output features a native scale factor of \u003cstrong\u003e7.87 V\/mm (200 mV\/mil)\u003c\/strong\u003e, making it fully compatible with raw vibration input channels on 3500 series machinery protection racks or directly linkable to external PLC\/DCS analog tachometer and condition-monitoring loops.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Analysis \u0026amp; Suffix Matrix\u003c\/h3\u003e\n\u003cp\u003eThe specific option configuration code \u003cstrong\u003e330980-50-05\u003c\/strong\u003e defines a highly specialized build, providing integrated mechanical rails and hazardous area framework coverage:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (330980):\u003c\/strong\u003e 3300 XL Narrow Side-view (NSv) Proximitor Sensor hardware platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal System Length (50):\u003c\/strong\u003e Calibrated exclusively for a \u003cstrong\u003e5.0-meter total electrical loop\u003c\/strong\u003e (e.g., combining a 0.5m probe with a 4.5m extension cable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Option (05):\u003c\/strong\u003e Integrated \u003cstrong\u003e35 mm DIN rail mounting framework\u003c\/strong\u003e. The module features structural ruggedized polymer feet designed to snap directly onto standard top-hat DIN tracks (EIA \/ IEC standards).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Option (05):\u003c\/strong\u003e \u003cstrong\u003eMultiple Approvals Certification\u003c\/strong\u003e. This covers comprehensive international safety protocols including ATEX, IECEx, and North American (CSA\/FM) intrinsic safety and non-incendive markings for Class I, Zone 0\/1\/2 environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReal Physical Dimensions \u0026amp; Total Cabinet Mass\u003c\/h3\u003e\n\u003cp\u003eIn high-density marshalling cabinets, substituting fake \"box dimensions\" for actual product envelopes results in critical thermal crowding and enclosure latch failures. Per official OEM design rules, the physical geometry and spatial clearances for the \u003cstrong\u003e330980-50-05\u003c\/strong\u003e DIN rail unit are strictly defined as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Module Structural Mass:\u003c\/strong\u003e \u003cstrong\u003e255 grams (9.0 oz)\u003c\/strong\u003e nominal dry weight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Footprint Height:\u003c\/strong\u003e \u003cstrong\u003e103.1 mm (4.06 in)\u003c\/strong\u003e absolute base-to-top execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Footprint Width:\u003c\/strong\u003e \u003cstrong\u003e81.3 mm (3.20 in)\u003c\/strong\u003e overall frame width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Footprint Depth:\u003c\/strong\u003e \u003cstrong\u003e61.2 mm (2.41 in)\u003c\/strong\u003e protrusion from the base plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe Critical Installation Clearance:\u003c\/strong\u003e \u003cstrong\u003e89.4 mm (3.52 in)\u003c\/strong\u003e. According to the engineering blueprints, when mounted to a standard 35 mm DIN rail, a minimum clearance depth of 89.4 mm from the backplate is required to safely engage, pivot, and remove the Proximitor assembly without bending adjacent structural wire ducts or pinching terminal connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCritical radial shaft vibration decoding on high-speed centrifugal refrigeration and air compressors.\u003c\/li\u003e\n\u003cli\u003eDual-direction axial thrust position drift capture inside confined turbo-expander gearboxes.\u003c\/li\u003e\n\u003cli\u003eMulti-point speed sensing and Keyphasor phase reference logging on narrow-target generator shafts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrecise Engineering Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrdering Model ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980-50-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signaling Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear -4 Vdc to -20 Vdc (Operational envelope bounds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal over linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range Span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 to 1.25 mm (10 to 50 mils) starting from target face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 12 mA from negative voltage rail (-24 Vdc supply card required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Load Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 10 kohm recommended interface resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial Connector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated miniature ClickLoc threaded interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block Layout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-terminal strip, accepts wire sizes up to 1.5 mm squares (16-24 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMarshalling Cabinet \u0026amp; Field Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe 5.0-Meter Circuit Match Rule:\u003c\/strong\u003e This 330980-50-XX Proximitor \u003cstrong\u003emust\u003c\/strong\u003e utilize an extension cable and probe layout that sums to exactly 5.0 meters of physical core line. Connecting this unit to a 7.0m or 9.0m cable system throws off the internal oscillator circuit’s balance, causing severe scaling distortion and triggering false channel warnings on the control panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Group Thermal Spacing:\u003c\/strong\u003e While the 330980-50-05 operates efficiently up to +100 degC, when grouping more than ten Proximitors sequentially on a single DIN track within an unventilated junction box, maintain a minimum of 10 mm lateral spacing or install an active air baffle to avoid heat concentration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Polarity Tracking:\u003c\/strong\u003e The terminal strip requires a negative power supply input (typically -24 Vdc). Wiring a standard positive instrument loop (+24 Vdc) to the power terminals will completely disable the unit and risks causing permanent reverse-polarity damage to the active RF output buffer stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Continuity and Isolation:\u003c\/strong\u003e The coax outer sheath ring connects directly to the internal terminal grid. Ensure the field instrumentation cable shield running from the Proximitor to the DCS is grounded at \u003ci\u003eone single point\u003c\/i\u003e (typically at the control room rack ground) to avoid creating massive 50\/60 Hz electromagnetic loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666857161067,"sku":"330980-50-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-50-05-proximitor-sensor-no5pi4jikgo_188a2339-042a-4d3d-b637-d017f2b5bdd2.jpg?v=1765449211"},{"product_id":"bently-nevada-330980-71-cn-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-71-CN 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-71-CN\u003c\/strong\u003e is a high-performance eddy-current proximity pre-amplifier designed to operate as the core signal processing component within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This driver module is engineered to convert the raw high-frequency radio frequency (RF) signal captured by an embedded proximity probe into a continuous, linear analog voltage output. With a nominal Average Scale Factor (ASF) of 7.87 V\/mm (200 mV\/mil), it delivers precise shaft displacement and dynamic vibration data to host machinery protection monitors, making it an essential component for the structural monitoring of high-speed centrifugal air compressors, refrigeration compressors, and process gas machinery with tight installation envelopes.\u003c\/p\u003e\n\u003cp\u003eIn terms of retrofitting and system lifecycle maintenance, the \u003cstrong\u003e330980-71-CN\u003c\/strong\u003e provides direct mechanical and electrical backward compatibility, allowing it to seamlessly replace legacy 3300 RAM transducer systems as well as 3000-series or 7000-series 190 transducer frameworks without requiring a complete teardown of existing field-routed probes or extension cables. This specific model represents a 7.0-meter total loop calibration profile configured for high-density 35 mm DIN rail mounting and features a specialized country-specific suffix for localized regulatory compliance. Enclosed in a rugged A380 die-cast aluminum housing and equipped with proprietary tool-free SpringLoc terminal blocks, the sensor provides enhanced immunity to industrial radio frequency interference (RFI) and electromagnetic noise (EMI) across complex industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for small-target applications and restricted side-view envelopes, including narrow shafts down to 51 mm or flat surfaces down to 15 mm.\u003c\/li\u003e\n\u003cli\u003eDelivers a stable 1.5 mm (60 mils) linear measurement range starting approximately 0.25 mm from the connected probe tip face.\u003c\/li\u003e\n\u003cli\u003eFeatures integrated SpringLoc terminal strips that establish highly vibration-resistant electrical connections without the need for specialized installation tools.\u003c\/li\u003e\n\u003cli\u003eHigh-density DIN rail mount design providing superior RFI\/EMI shielding to allow direct back-to-back installation inside crowded control cabinets.\u003c\/li\u003e\n\u003cli\u003eRugged A380 aluminum housing construction offering exceptional structural integrity and an extremely low thermal expansion coefficient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density panel installations on standard 35 mm DIN rails for radial shaft vibration tracking on high-speed industrial turbo-machinery.\u003c\/li\u003e\n\u003cli\u003ePrecision rotor axial thrust position offset and fluid-film bearing wear monitoring in compact process gas expanders.\u003c\/li\u003e\n\u003cli\u003eHigh-frequency phase reference tracking, tachometer speed measurements, and zero-speed sensor calibration via Keyphasor signal loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAA: System Length \u0026amp; Mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-71\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet) system length, 35 mm DIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBB: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-CN\u003c\/td\u003e\n\u003ctd\u003eCertified for regional regulatory compliance (China localized standard marks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 59.2827%;\"\u003e\u003cstrong\u003ePrecise Engineering Data\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003ePart Number Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e330980-71-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003eEddy Current Proximity Pre-amplifier \/ Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e1.5 mm (60 mils) absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eRecommended Gap Voltage Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e-9.0 Vdc nominal midpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003ePower Input Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eOutput Impedance Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e50 ohm nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eSystem Length Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e7.0 meters (must match the sum of probe and extension cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003eHigh-density 35 mm standard DIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eEnclosure Material Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003eA380 Die-cast Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eWiring Terminal Structure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003eSpringLoc terminal strips; accepts 0.2 to 1.5 mm2 (16 to 24 AWG) wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eRelative Humidity Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e100% condensing, non-submersible when terminals are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eSystem Frequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eNet Sensor Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e255 grams (9.0 oz) nominal standard dry mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal\/Connector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial ClickLoc Barrel Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts the gold-plated miniature coaxial plug from the 3300 NSv extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpringLoc Terminal: COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon \/ Circuit ground reference link returning to the monitoring rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpringLoc Terminal: OUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog negative DC voltage output signal proportional to the dynamic probe gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpringLoc Terminal: VT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Power Supply input terminal receiving negative supply voltage (-24 Vdc nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Loop Matching Rule:\u003c\/strong\u003e This Proximitor sensor is factory-calibrated for a total electrical loop length of exactly 7.0 meters. The combined physical lengths of the connected 3300 NSv probe and the 3300 NSv extension cable \u003cstrong\u003emust\u003c\/strong\u003e equal 7.0 meters (e.g., a 0.5-meter probe paired with a 6.5-meter extension cable) to prevent severe scale factor calibration errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting Securement:\u003c\/strong\u003e When snapping the module onto a standard 35 mm DIN rail, ensure that the plastic spring-loaded release clip underneath completely engages. For multi-channel installations, maintain a slight physical air gap between adjacent modules to facilitate natural convection cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring Wire Gauges:\u003c\/strong\u003e SpringLoc terminal blocks accommodate solid or stranded copper conductors ranging from 0.2 to 1.5 mm2 (16 to 24 AWG). If crimped wire ferrules are deployed, limit the maximum cross-sectional area to 0.75 mm2 (18 AWG) to ensure correct structural latching inside the clamp.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Protection:\u003c\/strong\u003e Although the internal circuits are ruggedized against static voltage transients, field technicians must follow standard ESD precautions and ground themselves before managing coaxial terminations, wiring signal leads, or interacting with terminal blocks to avoid damaging sensitive input stages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e Complies with European Community Directive 2014\/30\/EU, meeting EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions) standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e Conforms to European Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e Provides an Environment-Friendly Use Period (EFUP) designation of 15 years, tested in accordance with SJ\/T 11364-2024.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegional Compliance (-CN):\u003c\/strong\u003e Meets designated localized criteria for hazardous area installations within Mainland China jurisdictions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666858078571,"sku":"330980-71-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-71-cn-nsv-proximitor-sensor-sipbsk22c5a_69e61be9-6793-4474-86f9-5ca0ab1bf2d6.jpg?v=1765449236"},{"product_id":"bently-nevada-330980-70-05-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-70-05 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eThe Bently Nevada 330980-70-05 is a high-precision eddy current measurement device configured as a 3300 XL NSv Proximitor Sensor for critical machinery vibration monitoring. This specialized sensor converts the radio frequency (RF) signal generated by a proximity probe into a proportional voltage output, enabling precise tracking of static position and dynamic displacement. It is specifically designed to work with the 3300 NSv probe and extension cable in confined installations with tight counterbore, sideview, or rearview restrictions that limit standard proximity systems. The specific model configuration dictates a \u003cstrong\u003e7.0-meter system length\u003c\/strong\u003e matching options for panel mounting and carries no specific hazardous area agency approvals. Operating as a critical module within turbomachinery protection systems, it delivers stable performance for small shaft diameters and target surfaces down to 15 millimeters.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmall Target Optimization:\u003c\/strong\u003e Specifically calibrated to provide linear, reliable metrics on shaft targets down to 51 millimeters for radial vibration or 15 millimeters for axial position tracking.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTight Space Compatibility:\u003c\/strong\u003e Engineering design replaces legacy 3300 RAM and 3000\/7000-series systems where sideview restrictions compromise standard 5mm and 8mm probes.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e7.0-Meter Tuning:\u003c\/strong\u003e Internally balanced and calibrated for exact matching with a total probe and extension cable length of 7.0 meters to maintain signal integrity without field modifications.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePanel Mount Chassis:\u003c\/strong\u003e Rigid structural frame designed for straightforward installation within internal instrumentation enclaves and standard termination cabinets.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh Noise Rejection:\u003c\/strong\u003e Shielded electronics minimize RF interference and cross-talk across long-distance monitor room loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eRadial vibration and position tracking loops on centrifugal air compressors.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eThrust displacement and axial position monitoring in industrial refrigeration compressors.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eTachometer, zero-speed, and phase reference Keyphasor measurements on small-diameter process gas compressor shafts.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eCondition monitoring systems for fluid-filmed bearing machines with tight physical enclosure limitations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eOption Prefix\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eSelected Option Field\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eTechnical Configuration Meaning\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e330980\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBase Model Part\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3300 XL NSv Proximitor Sensor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e-70\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTotal System Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e7.0 meters (23.0 feet), panel mount hardware\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e-05\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAgency Approval\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNo approvals required\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Power Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-17.5 VDC to -26 VDC current loop; 12 mA maximum consumption\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eScale Factor (ASF)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e7.87 V\/mm (200 mV\/mil) nominal response\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eLinear Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.5 mm (60 mils) starting at roughly 0.25 mm (10 mils) from probe tip\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-35 degC to +85 degC (-31 degF to +185 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100% condensing, non-submerged, when connector parts are protected\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Impedance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e50 Ohm terminal signal configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eChassis Design\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eA380 aluminum panel-mount frame configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eU.S.A.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.34 Kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e115 mm x 95 mm x 75 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eTerminal Label\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOUT\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eProportional voltage output signal path (200 mV\/mil output loop)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSignal common return reference point\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eVTX\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNegative DC excitation power input (-24 VDC nominal supply line)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCoaxial Jack\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSecure connection interface to the 3300 NSv extension cable link\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and entirely disconnect external loop power before beginning installation tasks. Running structural or wiring maintenance on active, energized proximity loops poses severe risks of transient loop faults, erratic diagnostic readouts, or accidental machinery shutdown command generation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eField engineers must strictly observe the following technical sequence during field cabinet deployment:\u003c\/p\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eAlign the hardware frame on the clean chassis backplane inside the enclosure and tighten the panel screws to achieve a firm structural ground loop path.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eVerify total line length compatibility. The overall combination of the 3300 NSv probe and extension cable must equal exactly 7.0 meters to ensure accurate scaling parameters.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the coaxial terminal fitting of the extension cable into the integrated sensor receptacle, taking precautions to prevent mechanical binding or over-torque.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eLand the VTX, COM, and OUT wires into their distinct screw terminals on the block connector, maintaining separation from noisy motor electrical pathways.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666868433259,"sku":"330980-70-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-70-05-3300-nsv-proximity-sensor-k510l25av2w_6bbfe511-4603-4e4e-b382-7872a110f62b.jpg?v=1765449542"},{"product_id":"bently-nevada-330980-50-cn-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-50-CN 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330980-50-CN\u003c\/strong\u003e is a high-performance proximity sensor designed for use within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e is specifically optimized for industrial machinery with tight installation requirements, small targets, or where counterbore and side-view restrictions limit standard transducer systems. The \u003cstrong\u003e330980-50-CN\u003c\/strong\u003e model features a 5.0-meter system length option configuration specifically engineered for panel mounting, providing an average scale factor of 7.87 V\/mm (200 mV\/mil) over a 1.5 mm (60 mils) linear range. It plays a critical role in fluid-filmed bearing machinery by converting eddy current signals from a proximity probe into a proportional voltage output for continuous vibration, speed, and position monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides an Average Scale Factor of 7.87 V\/mm (200 mV\/mil) for precise proximity measurements.\u003c\/li\u003e\n\u003cli\u003eCompact and thin design allows high-density installation configurations.\u003c\/li\u003e\n\u003cli\u003eEquipped with SpringLoc terminal strips for fast, secure field wiring without specialized tools.\u003c\/li\u003e\n\u003cli\u003eEnhanced RFI\/EMI immunity prevents adjacent high-frequency radio signals from impacting system operation.\u003c\/li\u003e\n\u003cli\u003eIntegrated protection against electrostatic discharge on terminals and connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors \u003c\/li\u003e\n\u003cli\u003eRefrigeration compressors \u003c\/li\u003e\n\u003cli\u003eProcess gas compressors \u003c\/li\u003e\n\u003cli\u003eRadial vibration and radial position measurements on small shafts \u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements on small flat targets \u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed, and phase reference (Keyphasor) signaling \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 24.6108%;\"\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 75.0654%;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.6108%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: Total Length and Mounting Option\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 75.0654%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.6108%;\"\u003e-50\u003c\/td\u003e\n\u003ctd style=\"width: 75.0654%;\"\u003e5.0 meters (16.4 feet) system length, panel mount \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.6108%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eB: Agency Approval Option\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 75.0654%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.6108%;\"\u003e-CN\u003c\/td\u003e\n\u003ctd style=\"width: 75.0654%;\"\u003eATEX\/IECEx international approvals with local Chinese NEPSI industrial safety and explosion-proof certifications, along with compliance with Chinese RoHS regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers at 12 mA max consumption; -23 Vdc to -26 Vdc with barriers \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), starting at approximately 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5%\/-20% over linear range \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical (with up to 305 meters of field wiring) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Cable Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) [0.25 to 0.75 mm2 (18 to 23 AWG) with ferrules] \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Field Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) between Proximitor Sensor and monitor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e The device is configured for traditional panel mounting. Ensure secure fastening to prevent structural vibration from affecting performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Use three-conductor shielded triad cable for connection to the monitor. Strip wires and connect via the tool-free SpringLoc terminal strips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD):\u003c\/strong\u003e Observe proper ESD precautions during handling and installation to protect internal electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Use connector protectors on probe-to-cable and cable-to-sensor connections to prevent fluid ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive 2014\/30\/EU:\u003c\/strong\u003e EN 61000-6-2 (Industrial具Immunity), EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive 2011\/65\/EU:\u003c\/strong\u003e Compliant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e EFUP designation of 15 years per SJ\/T 11364-2024.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 (HFT = 0), SIL 3 (HFT = 1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III. Class I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc \/ ec IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668298002795,"sku":"330980-50-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330980-50-CN-ige1xxa20xh_4e6a7407-85eb-4c06-a815-93b5a56e8f57.jpg?v=1765520466"},{"product_id":"bently-nevada-330980-51-cn-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-51-CN 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-51-CN\u003c\/strong\u003e is a high-performance proximity sensor designed for use within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This eddy current sensor provides precise non-contacting vibration and position measurements on machinery with tight installation constraints or small target areas, such as centrifugal air compressors, refrigeration compressors, and process gas compressors. By operating with an Average Scale Factor of 7.87 V\/mm (200 mV\/mil), the \u003cstrong\u003e330980-51-CN\u003c\/strong\u003e delivers highly accurate radial vibration, radial position, axial position, tachometer, and phase reference (Keyphasor) signals from fluid-filmed bearing machines.\u003c\/p\u003e\n\u003cp\u003eEngineered with a compact and thin form factor, this \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e is specifically configured for high-density 35 mm DIN-rail mounting, allowing industrial operators to optimize enclosure space. The device boasts enhanced immunity to radio frequency interference (RFI) and electromagnetic interference (EMI), ensuring signal integrity without needing specialized mounting hardware or isolated enclosures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOffers 1.5 mm (60 mils) of linear range, optimizing side-view and small-target measurement capability.\u003c\/li\u003e\n\u003cli\u003eEquipped with integrated SpringLoc terminal strips that enable swift, reliable field wiring connections without requiring specialized installation tools.\u003c\/li\u003e\n\u003cli\u003eProvides exceptional RFI\/EMI immunity to prevent high-frequency radio signals from degrading transducer performance.\u003c\/li\u003e\n\u003cli\u003eDesigned to directly replace legacy 3300 RAM Transducer Systems and 3000-series or 7000-series 190 Transducer Systems.\u003c\/li\u003e\n\u003cli\u003eEmploys internal protection circuits against electrostatic discharge on terminal and connector surfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors \u003c\/li\u003e\n\u003cli\u003eRefrigeration compressors \u003c\/li\u003e\n\u003cli\u003eProcess gas compressors \u003c\/li\u003e\n\u003cli\u003eFluid-filmed bearing machinery with small shafts or reduced side-view spacing \u003c\/li\u003e\n\u003cli\u003eRadial vibration and axial (thrust) position monitoring \u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed, and Keyphasor phase reference signal tracking \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximitor Sensor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e5.0 metre (16.4 feet) system length, DIN mount \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: Approvals country specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Input\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers; -23 Vdc to -26 Vdc with barriers; 12 mA maximum consumption \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupply Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils); begins at approx. 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRecommended Gap\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% including interchangeability error \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDSL Deviation\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eSpringLoc terminal strips \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e8.13 cm x 6.12 cm x 6.35 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (Tested to IEC 68-2-3 damp heat) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Designed to fit securely onto standard 35 mm DIN rails via its specialized high-density integrated base mount. Ensure the rail is properly secured and grounded to the enclosure grid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Supports wire cross-sections from 0.2 to 1.5 mm2 (16 to 24 AWG), or 0.25 to 0.75 mm2 (18 to 23 AWG) when utilizing wire ferrules. A three-conductor shielded triad cable is recommended for connections between the sensor and the monitoring rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Distance:\u003c\/strong\u003e The maximum allowable cable distance between the Proximitor Sensor and the monitoring system is 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Utilize an ESD wrist strap and follow safety handling procedures during terminal wiring to shield internal circuitry from electrostatic discharge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e Complies with European Community Directive 2014\/30\/EU, EN 61000-6-2 (Immunity for Industrial Environments), and EN 61000-6-4 (Emissions for Industrial Environments).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e Certified for use in safety-instrumented systems up to SIL 2 (with HFT = 0) and SIL 3 (with HFT = 1).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668315959659,"sku":"330980-51-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330980-51-cn-t1vqrvgdjgl.jpg?v=1765519934"},{"product_id":"bently-nevada-330980-70-cn-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-70-CN 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330980-70-CN\u003c\/strong\u003e is a non-contacting \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e designed as an essential part of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This sensor is optimized for use with centrifugal air compressors, refrigeration compressors, process gas compressors, and other rotating machinery with tight installation space or small target constraints. It is primarily applied on fluid-filmed bearing machines to measure radial vibration, radial position, axial position, phase reference (Keyphasor signals), and zero-speed tachometer parameters. The design excels in environments where sideview, rearview, or counterbore restrictions eliminate the use of standard 5 mm and 8 mm transducer variants.\u003c\/p\u003e\n\u003cp\u003eWith a compact mechanical footprint, this \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e provides a 1.5 mm (60 mils) linear range and is configured for a standard 7.0-meter system length with a traditional panel mount orientation. It includes integrated SpringLoc terminal strips that deliver robust, vibration-resistant field connections without requiring specialized compression tools. Additionally, advanced internal protection circuitry yields high RFI\/EMI immunity, allowing the device to fulfill European CE mark parameters without demanding dedicated shielded enclosures or isolated mounting brackets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimizes proximity tracking on rotating machinery featuring restricted access, tight target constraints, and small shaft profiles.\u003c\/li\u003e\n\u003cli\u003eFlat panel mount design base tabs facilitate direct secure installation against junction box walls or enclosure frames.\u003c\/li\u003e\n\u003cli\u003eBuilt-in SpringLoc terminal strips offer reliable field wiring termination that withstands continuous structural vibration.\u003c\/li\u003e\n\u003cli\u003eAdvanced RFI\/EMI internal suppression preserves signal tracking accuracy against high-frequency radio signal interference.\u003c\/li\u003e\n\u003cli\u003eStandardized calibration profile tailored for AISI 4140 steel target faces under nominal factory conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eRefrigeration compressors\u003c\/li\u003e\n\u003cli\u003eProcess gas compressors\u003c\/li\u003e\n\u003cli\u003eRadial vibration and fluid-filmed bearing position tracking on small machinery shafts\u003c\/li\u003e\n\u003cli\u003eThrust (axial) position tracking on small flat surfaces\u003c\/li\u003e\n\u003cli\u003ePhase reference tracking and zero-speed tachometer inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Length and Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003e7.0 metres (22.9 feet) system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eApprovals country-specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Input Profile\u003c\/td\u003e\n\u003ctd\u003eAccepts input from one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Voltage Requirements\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers), 12 mA maximum current consumption; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal under standard conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils); begins at approximately 0.25 mm (10 mils) from the target surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than plus\/minus 0.06 mm (plus\/minus 2.3 mils) over the linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupply Voltage Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWiring Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated SpringLoc terminal strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMounting Design\u003c\/td\u003e\n\u003ctd\u003ePanel mount base layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when terminal connection paths are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Mount the sensor flat against the intended enclosure plate or layout junction panel using the structural mounting tabs on the sensor base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Interface:\u003c\/strong\u003e Strip field triad cable lines to the recommended engineering length and insert directly into the SpringLoc terminal paths. Standard terminals accept wire sizes from 0.2 to 1.5 mm2 (16 to 24 AWG).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Distance Constraints:\u003c\/strong\u003e Ensure that the cumulative field wiring loop distance separating the Proximitor Sensor from the monitoring system rack does not exceed 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Precautions:\u003c\/strong\u003e Maintain body isolation from common mechanical grounds via proper installation accessories to shield the measurement circuit from potential ground loops and electrical background noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e Compliant with European Community Directive 2014\/30\/EU via EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Fulfills country-specific safety codes designated under the CN option configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668317041003,"sku":"330980-70-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330980-70-cn-c15gvnluj3p_40d25a62-89c1-4ddd-9fde-e333b4a3dfb1.jpg?v=1765521057"},{"product_id":"bently-nevada-330980-71-05-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-71-05 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-71-05\u003c\/strong\u003e is a high-performance \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e engineered by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e for specialized eddy-current machinery protection systems. This proximity sensor is purposefully optimized for demanding industrial deployment areas featuring compact installation constraints, such as centrifugal air compressors, process gas machinery, and refrigeration compression skids. It operates as a critical signal conditioner, converting raw electromagnetic gaps into a linear voltage signal to track machine health parameters.\u003c\/p\u003e\n\u003cp\u003eThe specific variant \u003cstrong\u003e330980-71-05\u003c\/strong\u003e is designated for a \u003cstrong\u003e7.0-meter (23.0 feet) total system loop length\u003c\/strong\u003e and is equipped with an integrated \u003cstrong\u003eDIN-rail mounting track pad\u003c\/strong\u003e. It includes \u003cstrong\u003eMultiple Agency Approvals\u003c\/strong\u003e for universal hazardous area safety installation compliance. Featuring robust RFI\/EMI shielding and specialized SpringLoc terminal blocks, this thin-profile aluminum sensor provides high-stability signal fidelity and effortless field wire terminations without the need for specialized routing tools.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for small-shaft targets under 51 mm (2 inches) and restricted side-view or counterbore clearances.\u003c\/li\u003e\n\u003cli\u003eConfigured for a 7.0-meter total system loop length balancing length requirements across compact infrastructure layouts.\u003c\/li\u003e\n\u003cli\u003eSnap-on 35mm DIN-rail mounting base plate ensuring reliable electrical isolation from structural enclosure grounds.\u003c\/li\u003e\n\u003cli\u003eMultiple hazardous area approvals certified for universal deployment across global plant environments.\u003c\/li\u003e\n\u003cli\u003eToolless SpringLoc terminal strip arrangement enabling fast, high-integrity field wiring connectivity.\u003c\/li\u003e\n\u003cli\u003eAdvanced onboard RFI\/EMI filtering achieving European CE compliance without restrictive shielding barriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy radial vibration tracking and relative shaft position metrics on small-diameter high-speed rotors.\u003c\/li\u003e\n\u003cli\u003eCritical axial thrust displacement monitoring on fluid-filmed bearings with restrictive counterbore paths.\u003c\/li\u003e\n\u003cli\u003ePrecision zero-speed tracking, tachometer loops, and Keyphasor phase reference logging on industrial compressor skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980-71-05 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Hardware Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated DIN-rail mount backing pad \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05 = Multiple Approvals (North America, ATEX\/Europe, IECEx, Brazil) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) typical when calibrated to AISI 4140 steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), beginning at approx 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 NSv or 3300 RAM probe and cable loop \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (Unbarrier-assisted maximum consumption 12 mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response Boundaries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical (with up to 305m field wiring) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Target Terminal Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm squares (16 to 24 AWG) solid or stranded \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Structural Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA380 die-cast aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Component Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 grams (9 ounces) typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible with protected ClickLoc connections \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClickLoc Coaxial Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-loss gold-plated brass female thread port securing the incoming extension cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpringLoc Terminal Strip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-station toolless spring cage landing for Signal, Common, and Supply wiring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Pad Track Tabs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStructural clip array mating the isolated casing onto standard 35mm DIN-rails \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment:\u003c\/strong\u003e Snap the Proximitor Sensor base pad securely onto standard 35mm DIN rail tracks. Ensure the underlying replacement mounting pad isolates the metal chassis frame from raw cabinet ground grids to eliminate loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched Loop Length Balance:\u003c\/strong\u003e Verify that the combined mechanical lengths of the attached 3300 NSv probe and extension cable sum to exactly 7.0 meters to maintain calibrated scale factors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wire Termination:\u003c\/strong\u003e Use recommended three-conductor shielded triad cable (16 to 24 AWG). Depress the SpringLoc cage clips to seat bare wire ends completely before releasing tension.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Weatherproofing:\u003c\/strong\u003e Install specialized male\/female connector protectors or apply a wrap of self-fusing silicone tape over the coaxial links to block process fluids and maintain 100% condensing humidity defenses.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668334342507,"sku":"330980-71-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330980-71-05-w4t4nu5gz1z_6c5fa473-8266-4734-87b8-42bf5db3ac2d.jpg?v=1765521444"}],"url":"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-nsv-proximitor-sensor.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}