{"title":"Bently Nevada 3300 System Monitoring","description":"\u003cp\u003eThe Bently Nevada 3300 System Monitoring platform is a legacy machinery protection solution widely recognized for its reliability in industrial environments. Its architecture features a rack-based design housing individual monitors for vibration, temperature, and thrust, supported by common power supplies and communication modules. Technical characteristics include analog meter displays or digital readouts, with robust relay logic for machine protection. Functionally, the 3300 system interfaces with \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-7200-3300-interconnect-cables\"\u003e7200 \u0026amp; 3300 interconnect cables\u003c\/a\u003e and sensors to provide real-time status of rotating machinery. While succeeded by the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3500-system-machinery-protection\"\u003e3500 System\u003c\/a\u003e, the 3300 series remains a critical component in many plants, requiring high-quality spare parts to ensure continued operation and protection of essential turbines, pumps, and industrial motors.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-130732-01-3300-55-velomitor-quad-relays","title":"Bently Nevada 130732-01 3300\/55 Velomitor Quad Relays","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 130732-01\u003c\/strong\u003e is a rear-mounted \u003cstrong\u003e3300\/55 Velomitor Quad Relays\u003c\/strong\u003e module designed for use with the 3300\/55 Dual Velocity Monitor in the 3300 System rack. This relay module provides four programmable relay contacts specifically configured for Velomitor transducer inputs. Installed directly behind the main 3300\/55 monitor, the \u003cstrong\u003e130732-01\u003c\/strong\u003e handles alarm output relay switching for Alert and Danger status indications to support automated machinery protection and plant safety systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides four dedicated relay contact outputs (Quad Relays) per monitor card.\u003c\/li\u003e\n\u003cli\u003eDesigned for interface with 3300\/55 Dual Velocity Monitors operating with Velomitor transducers.\u003c\/li\u003e\n\u003cli\u003eMounts directly into the rear position behind the 3300\/55 monitor in a standard 3300 rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection and continuous vibration monitoring for industrial rotating equipment\u003c\/li\u003e\n\u003cli\u003eAutomated Alert and Danger trip relay switching in power generation, oil and gas, and petrochemical facilities\u003c\/li\u003e\n\u003cli\u003eSignal relay interface for machinery monitoring with Bently Nevada 3300 Series TSI systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e130732-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVelomitor Quad Relays Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e130732-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVelomitor Quad Relays Module (ATEX approved variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Position\u003c\/td\u003e\n\u003ctd\u003eInstalls in the rear slot behind the 3300\/55 monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (+32 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eALERT NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlert Relay Normally Closed Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eALERT ARM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlert Relay Common Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eALERT NO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlert Relay Normally Open Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANGER NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDanger Relay Normally Closed Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANGER ARM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDanger Relay Common Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANGER NO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDanger Relay Normally Open Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the 3300 system rack power is turned off or proper safety procedures are followed before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eAlign and seat the relay module into the rear slot directly behind the corresponding 3300\/55 Dual Velocity Monitor.\u003c\/li\u003e\n\u003cli\u003eSecure the card in place by tightening the top and bottom mounting screws.\u003c\/li\u003e\n\u003cli\u003eWire field alarm and shutdown contact loops to the rear terminal connections following system wiring diagrams.\u003c\/li\u003e\n\u003cli\u003eFor Quad Relays, external AND voting logic must be accomplished by wiring the contacts in series if required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Directives\u003c\/strong\u003e: EMC Directive (Certificate 158710), Low Voltage Directive (Certificate 135300)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e: CSA\/NRTL\/C Class I, Div 2, Groups A, B, C, D (T4 @ Ta = +65 degC); ATEX Ex nC[L] IIC T4 @ Ta = -20 degC to +60 degC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666745586027,"sku":"130732-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-130732-01-velomiter-terminal-card-circuit-board-assembly-bg4aunirewf_127a05c3-0390-4472-9bf0-42845a4f94e8.jpg?v=1765446942"},{"product_id":"bently-nevada-84152-01-3300-20-quad-relays-module","title":"Bently Nevada 84152-01 3300\/20 Quad Relays Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 84152-01\u003c\/strong\u003e is a Quad Relays Module designed as a spare relay module assembly for the Bently Nevada \u003cstrong\u003e3300\/20\u003c\/strong\u003e Dual Thrust Position Monitor. The \u003cstrong\u003e84152-01\u003c\/strong\u003e provides output relay switching functionality for monitoring systems within the Bently Nevada 3300 Series. Installed as part of the monitor assembly, it interfaces with the monitoring system to support alarm output signaling for machinery protection. Note that AND voting logic is not available directly within the module with Quad Relays; AND voting logic must be performed externally by wiring the contacts in series. Quad Relays are not compatible with the Internal Safety Barriers option.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for the Bently Nevada 3300\/20 Dual Thrust Position Monitor.\u003c\/li\u003e\n\u003cli\u003eProvides quad relay output switching configuration.\u003c\/li\u003e\n\u003cli\u003eEpoxy-sealed relay construction.\u003c\/li\u003e\n\u003cli\u003eRequires external contact series wiring for AND voting logic applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBently Nevada 3300\/20 Dual Thrust Position Monitoring Systems\u003c\/li\u003e\n\u003cli\u003eRotating Machinery Protection Systems\u003c\/li\u003e\n\u003cli\u003eIndustrial Machinery Alarm Relay Signal Interfacing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \/ GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Part Number\u003c\/td\u003e\n\u003ctd\u003e84152-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family \/ System\u003c\/td\u003e\n\u003ctd\u003e3300\/20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eQuad Relays (Epoxy-sealed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300\/20 Dual Thrust Position Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Safety Barrier Compatibility\u003c\/td\u003e\n\u003ctd\u003eNot available with Internal Safety Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure power to the 3300 rack is disconnected before installing or replacing the relay module assembly.\u003c\/li\u003e\n\u003cli\u003eWhen AND voting logic is required for alarm relay drive using Quad Relays, wire the relay contacts externally in series.\u003c\/li\u003e\n\u003cli\u003eDo not combine Quad Relays with the Internal Safety Barriers option.\u003c\/li\u003e\n\u003cli\u003eEnsure proper seating and attachment of the module to the monitor assembly PWA structure according to 3300 system manual guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850738539,"sku":"84152-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-84152-01-spare-relay-module-assemblies-2zdvbuyy4pt_4cdd8493-5e13-48a1-b422-20e2c362b20d.jpg?v=1765449038"},{"product_id":"bently-nevada-3300-30-six-channel-temperature-tc-input-monitor","title":"Bently Nevada 3300\/30 Six-Channel Temperature TC Input Monitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/30 Six-Channel Temperature Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a six-channel temperature monitoring module designed for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e.\u003cbr\u003eThis version is specifically configured to accept\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThermocouple (TC) inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erather than RTD sensors.\u003c\/p\u003e\n\u003cp\u003eIt is commonly used to monitor critical temperature points in industrial machinery, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBearing metal temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExhaust gas temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStator winding temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLube oil system temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe monitor provides continuous protection through configurable alarm relays and standard recorder outputs, ensuring reliable thermal supervision in turbine, compressor, and generator applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003e1. Inputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esix (6) independent thermocouple inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEach channel operates independently\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Thermocouple Types\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Iron \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Alumel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Copper \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInternal compensation provided at the terminal block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatically corrects measurement drift caused by ambient temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures stable temperature accuracy across operating environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWithin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±2.2% of signal\u003c\/strong\u003e, plus thermocouple tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReference temperature:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOpen Thermocouple Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor includes automatic fault detection when a thermocouple circuit opens.\u003c\/p\u003e\n\u003cp\u003eSelectable response modes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to high value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDownscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to low value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis feature prevents machinery from operating without temperature protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAll six channels scanned approximately:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.5 seconds per cycle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis scan speed is typical for machinery protection systems where temperature changes occur gradually compared to vibration signals.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Outputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUser-programmable analog outputs:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 to +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to -10 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 to +5 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvailable for diagnostic and monitoring purposes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel coaxial connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRear terminal block connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne buffered output per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese outputs are typically connected to:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDCS systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData recorders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. Alarms \u0026amp; Display\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e7-segment LCD temperature display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShows real-time temperature value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChannel selection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebutton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCycles through Channel 1 to Channel 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach channel supports independent alarm configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlert alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDanger alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth thresholds are fully adjustable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOK Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinuously monitors system health, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/30-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003chr\u003e\n\u003ch3\u003eA — Full-Scale Range Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eTemperature Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0 to 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0 to 500°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0 to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e32 to 212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e32 to 392°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e32 to 932°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003e32 to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — Thermocouple Input Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eThermocouple Type\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — Alarm Relay Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — Agency Approval Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCertification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX self-certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — Safety Barrier Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eExternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eInternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eSpace Requirement\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/30 temperature monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDouble-width module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation requirement:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOccupies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo (2) slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the 3300 rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is important when planning rack capacity in retrofit or expansion projects.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThermocouple Lead Wire Requirement\u003c\/h3\u003e\n\u003cp\u003eAlways use the correct\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouple extension wire\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat matches the thermocouple type.\u003c\/p\u003e\n\u003cp\u003eExamples:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType K → Type K extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType J → Type J extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing standard copper wire will introduce:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eJunction voltage errors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement drift\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration inaccuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is one of the most common field installation mistakes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGrounding Practice\u003c\/h3\u003e\n\u003cp\u003eRecommended grounding method:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround the thermocouple shield at the monitor rack only\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvoid grounding at multiple points.\u003c\/p\u003e\n\u003cp\u003eImproper grounding can cause:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGround loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnstable temperature readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpecial attention is required when using:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounded-tip thermocouples\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese sensors are more sensitive to grounding configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCold Junction Environment Control\u003c\/h3\u003e\n\u003cp\u003eDo not install the monitor rack in locations with:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRapid temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong airflow across terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh thermal gradients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese conditions can affect the accuracy of the internal cold junction compensation.\u003c\/p\u003e\n\u003cp\u003eTypical problematic locations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNear ventilation ducts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClose to turbine exhaust paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutdoor panels without thermal shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850935147,"sku":"3300\/30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-30-position-monitor-module-aahygilvquw_7ed0cd2c-10d0-4b8c-b33c-9c8d65d61045.jpg?v=1765449041"},{"product_id":"bently-nevada-3300-45-dual-differential-expansion-monitor","title":"Bently Nevada 3300\/45 Dual Differential Expansion Monitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/45 Dual-Channel Differential Expansion Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel monitor designed for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e.\u003cbr\u003eIt is specifically engineered to measure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDifferential Expansion\u003c\/strong\u003e, defined as the relative axial movement between the turbine shaft and the casing.\u003c\/p\u003e\n\u003cp\u003eThis parameter is critical for large steam turbines during startup and shutdown, where thermal expansion rates differ between rotating and stationary components. Accurate monitoring helps prevent rotor-to-casing contact, mechanical stress, and potential turbine damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003e1. Input \u0026amp; Signal Processing\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Input\u003c\/strong\u003e\u003cbr\u003eAccepts signals from non-contacting proximity probes, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e11 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e25 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50 mm Proximitor System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor supports multiple configuration methods depending on the mechanical design:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Single Composite\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUses one probe to measure a tapered collar or ramp surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommon in compact turbine designs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDual Complementary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUses two probes to increase measurement linearity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides redundancy for critical protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e±0.33% of full-scale (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReference temperature:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Outputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUser-programmable signal formats:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 to +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to -10 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 to +5 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel: Coaxial connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRear panel: Terminal block connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne output per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e100 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Alarms \u0026amp; Display\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual vertical bargraph LCD indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time differential expansion visualization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBi-directional alarm configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlert Alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDanger Alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigitally adjustable thresholds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOK Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OK LED monitors the health status of:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnected transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/45-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003ch3\u003eA — Full-Scale Range Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eMeasurement Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0.1-0-0.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0.2-0-0.2 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0.3-0-0.3 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0.4-0-0-0.4 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e2.0-0-2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e4.0-0-4.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e8.0-0-8.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e10-0-10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — Transducer Input Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCompatible Proximitor System\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e8 mm or 11 mm (200 or 100 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e25 mm (50 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e50 mm (25 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e7200 14 mm (100 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — Alarm Relay Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eQuad relay (Epoxy-sealed only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — Agency Approval Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCertification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX self-certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — Safety Barrier Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eExternal barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eInternal barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eTapered Collar Configuration\u003c\/h3\u003e\n\u003cp\u003eWhen a single probe is installed on a tapered collar:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe collar angle must be accurately configured in the monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThis ensures correct linear conversion from displacement to expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIncorrect angle configuration will directly affect measurement accuracy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCold vs. Hot Zero Reference\u003c\/h3\u003e\n\u003cp\u003eDifferential expansion monitoring follows a standard baseline method:\u003c\/p\u003e\n\u003cp\u003eCold condition:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe system is zeroed during machine startup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft and casing temperatures are stable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHot condition:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe monitor tracks expansion as thermal growth occurs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time displacement is calculated relative to the cold reference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis method is standard practice for steam turbine protection systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eRelay Voting Strategy (Recommended for Critical Turbines)\u003c\/h3\u003e\n\u003cp\u003eFor high-integrity protection systems:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAND voting logic (2-out-of-2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis recommended.\u003c\/p\u003e\n\u003cp\u003eThis configuration ensures:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA single probe failure will not trigger a false trip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoth channels must confirm an alarm condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis approach is widely used in turbine protection architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProbe Linearity Considerations\u003c\/h3\u003e\n\u003cp\u003eLarge-range proximity probes require precise mechanical setup.\u003c\/p\u003e\n\u003cp\u003eImportant differences:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e25 mm and 50 mm probes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHave a wider measurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRequire specific initial gap settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExhibit different linear regions compared to standard 8 mm probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImproper probe gapping may result in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReduced measurement accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-linear output response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFalse alarm conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852999531,"sku":"3300\/45","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-45-dual-differential-expansion-monitor-qopi2y5bigd_db33166e-83e4-4748-8b37-e0fd75bd5170.jpg?v=1765449102"},{"product_id":"bently-nevada-3300-12-power-supply-module","title":"Bently Nevada 3300\/12 AC Power Supply","description":"\u003cp\u003e\u003cspan class=\"citation-896\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-896\"\u003eBently Nevada 3300\/12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-896\"\u003e\u003cspan\u003e \u003c\/span\u003eis an AC power supply that provides reliable, regulated power for up to 12 monitors and their associated transducers within a 3300 rack\u003c\/span\u003e\u003cspan class=\"citation-896 citation-end-896\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-895\"\u003e\u003c\/span\u003eIt is installed in the left-most position (Position 1) of the rack\u003cspan class=\"citation-895 citation-end-895\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan class=\"citation-894\"\u003e\u003c\/span\u003eTechnical Specifications\u003cspan class=\"citation-894 citation-end-894\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ch4\u003e1. Input Power\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003eVoltage Options\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e: User-selectable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003e95 to 125 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e\u003cspan\u003e \u003c\/span\u003e(1.0 A max) or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-893\"\u003e190 to 250 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-893\"\u003e\u003cspan\u003e \u003c\/span\u003e(0.5 A max), single phase, 50 to 60 Hz\u003c\/span\u003e\u003cspan class=\"citation-893 citation-end-893\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-892\"\u003eField Changeable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-892\"\u003e: The input voltage can be changed in the field via a soldered jumper and by replacing the external fuse\u003c\/span\u003e\u003cspan class=\"citation-892 citation-end-892\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-891\"\u003ePower-up Surge\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-891\"\u003e: 26 A peak or 12 A rms for one cycle\u003c\/span\u003e\u003cspan class=\"citation-891 citation-end-891\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Outputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-890\"\u003eTransducer Power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-890\"\u003e: Delivers regulated DC voltage internal to the rack\u003c\/span\u003e\u003cspan class=\"citation-890 citation-end-890\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003eProgrammable Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e: Field-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003e-24 Vdc\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e\u003cspan\u003e \u003c\/span\u003e(+0%, -2.5%) or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-889\"\u003e-18 Vdc\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-889\"\u003e\u003cspan\u003e \u003c\/span\u003e(+1%, -2%)\u003c\/span\u003e\u003cspan class=\"citation-889 citation-end-889\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-888\"\u003eProtection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-888\"\u003e: Transducer voltages are overload protected on individual monitor circuit boards\u003c\/span\u003e\u003cspan class=\"citation-888 citation-end-888\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"citation-887\"\u003e\u003c\/span\u003e\u003cstrong\u003e3. OK Relay\u003c\/strong\u003e\u003cspan class=\"citation-887 citation-end-887\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e: Provides a system-level status indication.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-886\"\u003e\u003c\/span\u003eLoss of primary power, monitor failure, or transducer wiring failure will cause the relay to change state\u003cspan class=\"citation-886 citation-end-886\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-885\"\u003eType\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-885\"\u003e: Single-pole, double-throw (SPDT)\u003c\/span\u003e\u003cspan class=\"citation-885 citation-end-885\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-884\"\u003eSealing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-884\"\u003e: Hermetically-sealed\u003c\/span\u003e\u003cspan class=\"citation-884 citation-end-884\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Ratings\u003c\/strong\u003e: 5 A at 28 Vdc or 120 Vac;\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-883\"\u003e\u003c\/span\u003e3 A at 220 Vac (resistive load)\u003cspan class=\"citation-883 citation-end-883\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-882\"\u003eOperation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-882\"\u003e: Normally energized\u003c\/span\u003e\u003cspan class=\"citation-882 citation-end-882\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-881\"\u003e\u003c\/span\u003e4. Physical \u0026amp; Environmental\u003cspan class=\"citation-881 citation-end-881\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-880\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-880\"\u003e: 0°C to +65°C (+32°F to +150°F)\u003c\/span\u003e\u003cspan class=\"citation-880 citation-end-880\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-879\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-879\"\u003e: -40°C to +85°C (-40°F to +185°F)\u003c\/span\u003e\u003cspan class=\"citation-879 citation-end-879\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-878\"\u003eHumidity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-878\"\u003e: Up to 95% non-condensing\u003c\/span\u003e\u003cspan class=\"citation-878 citation-end-878\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-877\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-877\"\u003e: 1 kg (2.2 lbs.)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-876\"\u003e\u003c\/span\u003eOrdering Information (Suffix Codes)\u003cspan class=\"citation-876 citation-end-876\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOrder Format: 3300\/12-AXX-BXX-CXX\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-875\"\u003eA: Input Voltage Option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-875\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-875 citation-end-875\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 95-125 Vac, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 190-250 Vac, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-874\"\u003eB: Power Input Module (PIM) Option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-874\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-874 citation-end-874\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20\u003c\/strong\u003e: Standard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e22\u003c\/strong\u003e: Internal Safety Barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e23\u003c\/strong\u003e: Spare supply only (No PIM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-873\"\u003eC: Agency Approval Option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-873\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-873 citation-end-873\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Not Required\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"citation-872\"\u003e01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-872\"\u003e: CSA\/NRTL\/C (Class I, Div 2)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-872 citation-end-872\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-871\"\u003e02\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-871\"\u003e: ATEX self-certification\u003c\/span\u003e\u003cspan class=\"citation-871 citation-end-871\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eImportant Notes for Installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-870\"\u003eRedundancy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-870\"\u003e: A second power supply is\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-870\"\u003enever required\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-870\"\u003e\u003cspan\u003e \u003c\/span\u003ein the same 3300 rack\u003c\/span\u003e\u003cspan class=\"citation-870 citation-end-870\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-869\"\u003eNoise Filtering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-869\"\u003e: The 3300\/12 comes equipped with a line noise filter as standard\u003c\/span\u003e\u003cspan class=\"citation-869 citation-end-869\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-868\"\u003eSafety\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-868\"\u003e: It is strongly recommended to connect an external annunciator to the OK relay terminals to ensure operators are alerted to a loss of machinery protection\u003c\/span\u003e\u003cspan class=\"citation-868 citation-end-868\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666855850347,"sku":"3300\/12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-12-power-supply-module-rdqathnprlx_e7da0184-0869-4ca4-9c0f-d1e92e31bca5.jpg?v=1765449181"},{"product_id":"bently-nevada-3300-16-dual-xy-rv-vibration-monitor","title":"Bently Nevada 3300\/16 Dual XY\/RV Vibration Monitor","description":"\u003cp\u003e\u003cspan class=\"citation-826\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/16\u003c\/strong\u003e\u003cspan class=\"citation-826\"\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel vibration monitor from the legacy\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e3300 Monitoring System\u003c\/strong\u003e\u003cspan class=\"citation-826 citation-end-826\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed to provide continuous, online protection for rotating machinery by measuring radial vibration (RV) or XY shaft orbit. This module is essential for monitoring the mechanical health of centrifugal compressors, pumps, and motors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003e1. Input\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-825\"\u003e\u003c\/span\u003e\u003cstrong\u003eTransducer Type:\u003c\/strong\u003e\u003cspan class=\"citation-825\"\u003e\u003cspan\u003e \u003c\/span\u003eAccepts signals from Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eProximitor\u003c\/strong\u003e\u003cspan class=\"citation-825 citation-end-825\"\u003e\u003cspan\u003e \u003c\/span\u003eTransducer systems (non-contacting proximity probes).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensitivity:\u003c\/strong\u003e\u003cspan class=\"citation-824\"\u003e\u003cspan\u003e \u003c\/span\u003eUser-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e200 mV\/mil\u003c\/strong\u003e\u003cspan class=\"citation-824\"\u003e\u003cspan\u003e \u003c\/span\u003e(8 V\/mm) or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e100 mV\/mil\u003c\/strong\u003e\u003cspan class=\"citation-824 citation-end-824\"\u003e\u003cspan\u003e \u003c\/span\u003e(4 V\/mm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-823\"\u003e\u003c\/span\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cspan class=\"citation-823 citation-end-823\"\u003e\u003cspan\u003e \u003c\/span\u003e10 kOhm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Signal Conditioning\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Hz to 4.2 kHz (240 cpm to 252,000 cpm) for standard applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWithin ±0.33% of full-scale at room temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-822\"\u003e\u003c\/span\u003e\u003cstrong\u003ePeak-to-Peak Measurement:\u003c\/strong\u003e\u003cspan class=\"citation-822 citation-end-822\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitors the overall vibration displacement in mils or micrometers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e3. Outputs\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs:\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e\u003cspan\u003e \u003c\/span\u003eUser-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e+4 to +20 mA\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e0 to -10 Vdc\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e+1 to +5 Vdc\u003c\/strong\u003e\u003cspan class=\"citation-821 citation-end-821\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOutputs are proportional to the full-scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-820\"\u003e\u003c\/span\u003e\u003cstrong\u003eBuffered Transducer Outputs:\u003c\/strong\u003e\u003cspan class=\"citation-820 citation-end-820\"\u003e\u003cspan\u003e \u003c\/span\u003eAvailable via front panel coaxial connectors and rear terminal blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 Ohm (for voltage outputs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e4. Alarms \u0026amp; Displays\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisplays:\u003c\/strong\u003e\u003cspan class=\"citation-819 citation-end-819\"\u003e\u003cspan\u003e \u003c\/span\u003eDual vertical LCD bargraphs (one per channel).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlert and Danger levels are digitally adjustable from 0 to 100% of full-scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOK LED:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors the integrity of the probe, cable, and internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information (Suffix Codes)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format: 3300\/16-AXX-BXX-CXX-DXX-EXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eA: Full-scale Range Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 0-3 mils (peak-to-peak)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 0-5 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 0-10 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 0-15 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 0-100 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e07\u003c\/strong\u003e: 0-150 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e08\u003c\/strong\u003e: 0-200 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e09\u003c\/strong\u003e: 0-250 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eB: Transducer Input Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 3300 or 7200 Proximitor system (200 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 7200 11 mm Proximitor system (100 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 7200 14 mm Proximitor system (100 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 3300XL NSv and 3300 RAM (200 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eC: Alarm Relay Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-818\"\u003e\u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan class=\"citation-818 citation-end-818\"\u003e: Epoxy-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-817\"\u003e\u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan class=\"citation-817 citation-end-817\"\u003e: Hermetically-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Quad Relay (Epoxy-sealed only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: Spare Monitor - No SIM\/SIRM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eD: Agency Approval Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: CSA\/NRTL\/C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-816\"\u003e\u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan class=\"citation-816 citation-end-816\"\u003e: ATEX self-certification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eE: Safety Barrier Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: None\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: External\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Internal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eXY Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn XY monitoring, two probes are mounted 90 degrees apart on the same bearing.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-815 citation-end-815\"\u003eThe 3300\/16 processes these inputs to provide a comprehensive view of the shaft's radial movement (orbit).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Voting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe monitor is typically configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOR voting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Danger relay actuates if either channel reaches the setpoint) for radial vibration, unlike thrust monitors which often use AND voting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent interference, ensure the shield of the extension cable is grounded at the monitor end only. Never ground the shield at the Proximitor housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen replacing a module, the \"Bypass\" switch must be used to inhibit the relays and prevent a false machine trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860765547,"sku":"3300\/16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-16-dual-vibration-monitor-5zzrar1f3x1_a92c3e62-5038-4339-887c-ef3cde16ad1f.jpg?v=1765449289"},{"product_id":"bently-nevada-3300-35-six-channel-temperature-monitor","title":"Bently Nevada 3300\/35 Six-Channel Temperature Monitor","description":"\u003cp\u003e\u003cspan class=\"citation-786\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/35\u003c\/strong\u003e\u003cspan class=\"citation-786\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized temperature monitoring module within the legacy\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e3300 Monitoring System\u003c\/strong\u003e\u003cspan class=\"citation-786 citation-end-786\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-785 citation-end-785\"\u003eIt is designed to provide six independent channels of continuous, online temperature monitoring for critical machinery.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis module is specifically used with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eResistance Temperature Detectors (RTDs)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto monitor bearing temperatures, stator windings, and other vital thermal points in turbines, compressors, and pumps.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300\/35\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResistance Temperature Detectors (RTD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2.2% of signal (at +25°C \/ +77°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+4 to +20 mA, 0 to -10 Vdc, or +1 to +5 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +65°C (+32°F to +150°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo rack positions (Occupies 2 slots in 3300 Rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.8 kg to 2.8 kg (depending on configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-784\"\u003e\u003c\/span\u003e\u003cstrong\u003eSix Independent Channels\u003c\/strong\u003e\u003cspan class=\"citation-784 citation-end-784\"\u003e: Monitors six separate points simultaneously, allowing for comprehensive thermal protection in a compact footprint.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-783\"\u003e\u003c\/span\u003e\u003cstrong\u003eRTD Support\u003c\/strong\u003e\u003cspan class=\"citation-783 citation-end-783\"\u003e: Optimized for standard RTD types, most commonly 100\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003cspan class=\"citation-782 citation-end-782\"\u003e\u003cspan\u003e \u003c\/span\u003ePlatinum (0.00385 coefficient).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-781\"\u003e\u003c\/span\u003e\u003cstrong\u003eAlarms\u003c\/strong\u003e\u003cspan class=\"citation-781\"\u003e: Provides configurable\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eAlert\u003c\/strong\u003e\u003cspan class=\"citation-781\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eDanger\u003c\/strong\u003e\u003cspan class=\"citation-781 citation-end-781\"\u003e\u003cspan\u003e \u003c\/span\u003esetpoints for each channel to trigger early warnings or automatic machine trips.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFront Panel Interface\u003c\/strong\u003e: Features a 7-segment LCD display (instead of the bargraphs used on vibration modules) to show actual temperature values per channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information (Suffix Codes)\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/35 is configured using the following suffix code format:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/35-AXX-BXX-CXX-DXX-EXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eA: Full-scale Range Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 0 to 100°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 0 to 200°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 0 to 150°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 0 to 250°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 32 to 212°F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-780\"\u003e\u003c\/span\u003e\u003cstrong\u003e06\u003c\/strong\u003e\u003cspan class=\"citation-780 citation-end-780\"\u003e: 32 to 392°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cem\u003e(Other regional and custom ranges available)\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eB: Transducer Input Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 100 Ohm Platinum (0.00385) - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 100 Ohm Platinum (0.00392) - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 10 Ohm Copper - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 120 Ohm Nickel - 3-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 100 Ohm Platinum (0.00385) - 4-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eC: Alarm Relay Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-773\"\u003e\u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan class=\"citation-773 citation-end-773\"\u003e: Epoxy-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Hermetically-sealed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eD: Agency Approval Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-772\"\u003e\u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan class=\"citation-772 citation-end-772\"\u003e: Not required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: CSA\/NRTL\/C (Class 1, Div 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: ATEX self-certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eE: Safety Barrier Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: None\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: External Barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Internal Barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-771\"\u003e\u003c\/span\u003e\u003cstrong\u003eSpace Requirements\u003c\/strong\u003e\u003cspan class=\"citation-771\"\u003e: Unlike standard vibration monitors that occupy one slot, the 3300\/35 is a \"Double-Wide\" module and\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eoccupies two rack positions\u003c\/strong\u003e\u003cspan class=\"citation-771 citation-end-771\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e: For 3-wire RTDs, lead wire resistance compensation is critical for accuracy. Use high-quality shielded triad cable for all field connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLCD Display\u003c\/strong\u003e: The front panel \"Display\" button allows the user to cycle through the six channels to view current values, Peak Hold values, and Alarm Setpoints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863747435,"sku":"3300\/35","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-35-temperature-monitor-f4b5b4r5dcr_0c3a1823-f486-49d2-a5b3-91e8d2609dfd.jpg?v=1765449384"},{"product_id":"bently-nevada-3300-20-dual-thrust-position-monitor","title":"Bently Nevada 3300\/20 Dual Thrust Position Monitor","description":"\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-730\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-730\"\u003eBently Nevada 3300\/20\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-730\"\u003e is designed to provide early warning of thrust bearing failure by continuously monitoring two independent channels of shaft axial position\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-730 citation-end-730\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-729\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-729\"\u003eIt is highly recommended to use a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-729\"\u003e2-out-of-2 (AND voting)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-729\"\u003e configuration to prevent false trips caused by transducer failure\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-729 citation-end-729\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003e1. Input \u0026amp; Signal Processing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-728\"\u003eSignal Input:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-728\"\u003e Accepts one or two proximity probe signal inputs\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-728 citation-end-728\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-727\"\u003eInput Impedance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-727\"\u003e 10 kΩ\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-727 citation-end-727\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-726\"\u003eSensitivity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-726\"\u003e User-programmable for 200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-726 citation-end-726\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-725\"\u003eAccuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-725\"\u003e Within ±0.33% of full-scale typical, ±1% maximum at +25°C (+77°F)\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-725 citation-end-725\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-724\"\u003eNominal Consumption:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-724\"\u003e 1.5 watts\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-724 citation-end-724\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Outputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-723\"\u003eRecorder Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-723\"\u003e User-programmable for +4 to +20 mA, 0 to -10 Vdc, or +1 to +5 Vdc\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-723 citation-end-723\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-722\"\u003eBuffered Transducer Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-722\"\u003e One coaxial connector per channel on the front panel and one terminal connection per channel on the rear\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-722 citation-end-722\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-721\"\u003eOutput Impedance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-721\"\u003e 100 Ω\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-721 citation-end-721\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e3. Alarms \u0026amp; Displays\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-720\"\u003eAlarm Setpoints:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-720\"\u003e Alert and Danger alarms are bi-directional and digitally adjustable from 0 to 100% of full-scale\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-720 citation-end-720\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-719\"\u003eMeter Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-719\"\u003e Non-multiplexing vertical bargraph LCD per channel; includes a third center scale for Probe Gap\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-719 citation-end-719\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-718\"\u003eOK LED:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-718\"\u003e Indicates the condition of the monitor, transducers, and field wiring\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-718 citation-end-718\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information (Suffix Codes)\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-717\"\u003eFormat: 3300\/20-AXX-BXX-CXX-DXX-EXX\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-717\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-717 citation-end-717\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-716\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eA: Full-scale Range Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-716 citation-end-716\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 25-0-25 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 30-0-30 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 40-0-40 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 50-0-50 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 75-0-75 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e11\u003c\/strong\u003e: 0.5-0-0.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: 1.0-0-1.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e13\u003c\/strong\u003e: 2.0-0-2.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-715\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eB: Transducer Input Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-715 citation-end-715\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 3300 or 7200 Proximitor® systems, 200 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 7200 11 mm (not 3300XL) Proximitor system, 100 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 7200 14 mm or 3300 HTPS Proximitor systems, 100 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 3000 Proximitor® 200 mV\/mil (Requires -18 Vdc supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 3300XL NSv and 3300 RAM Proximitor Sensor, 200 mV\/mil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-714\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eC: Alarm Relay Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-714 citation-end-714\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Epoxy-sealed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Hermetically-sealed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Quad Relay (Epoxy-sealed only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: Spare Monitor - No SIM\/SIRM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-713\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eD: Agency Approval Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-713 citation-end-713\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: CSA\/NRTL\/C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: ATEX self-certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-712\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eE: Safety Barrier Option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-712 citation-end-712\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: None\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: External\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Internal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-711\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eField-programmable Jumper Options\u003c\/strong\u003e\u003cspan\u003e\u003cspan class=\"citation-711 citation-end-711\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-710\"\u003eDanger Relay Voting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-710\"\u003e: AND voting (factory default) or OR voting\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-710 citation-end-710\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-709\"\u003eDanger Relay Mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-709\"\u003e: Normally de-energized (factory default) or Normally energized\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-709 citation-end-709\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-708\"\u003eAlarm Time Delay\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-708\"\u003e: 0.1 sec, 1 sec, 3 sec, or 6 sec\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-708 citation-end-708\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-707\"\u003eThrust Direction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-707\"\u003e: Toward probe or Away from probe\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-707 citation-end-707\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666868400491,"sku":"3300\/20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-20-dual-thrust-position-monitor-wxm3vxeyvcp_681503f5-7659-4252-bc09-110981de32c6.jpg?v=1765449541"},{"product_id":"bently-nevada-81545-01-3300-20-transducer-i-o-and-record-terminals-dual-epoxy-relays-module","title":"Bently Nevada 81545-01 3300\/20 Transducer I\/O and Record Terminals \/ Dual Epoxy Relays Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE \/ Bently Nevada 81545-01\u003c\/strong\u003e is a Transducer I\/O and Record Terminals \/ Dual Epoxy Relays Module designed for use within the Bently Nevada \u003cstrong\u003e3300\/20\u003c\/strong\u003e Dual Thrust Position Monitor system. The \u003cstrong\u003e81545-01\u003c\/strong\u003e provides signal interfacing, transducer input\/output connectivity, recorder output connections, and relay contact management for thrust position monitoring applications. It works with the monitor to continuously measure and monitor two independent channels of shaft axial position relative to the axial clearances within rotating machinery, providing early warning of thrust bearing failure.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides early warning of thrust bearing failure by interfacing axial position signals.\u003c\/li\u003e\n\u003cli\u003eSupports continuous measuring and monitoring of two independent channels.\u003c\/li\u003e\n\u003cli\u003eInterfaces signal paths for shaft axial position measurement relative to machine axial clearances.\u003c\/li\u003e\n\u003cli\u003eIntegrates transducer I\/O, recorder terminals, and dual epoxy relays on a single rear terminal assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRotating Machinery Shaft Axial Position Monitoring\u003c\/li\u003e\n\u003cli\u003eThrust Bearing Failure Early Warning Systems\u003c\/li\u003e\n\u003cli\u003eIndustrial Machinery Protection Systems utilizing Bently Nevada 3300 Series hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE \/ Bently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Part Number\u003c\/td\u003e\n\u003ctd\u003e81545-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family \/ System\u003c\/td\u003e\n\u003ctd\u003e3300\/20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTransducer I\/O and Record Terminals \/ Dual Epoxy Relays Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the main 3300 system rack is powered off before inserting or removing the rear terminal module.\u003c\/li\u003e\n\u003cli\u003eVerify that transducer field wiring and recorder signal lines are correctly routed to the designated terminal blocks.\u003c\/li\u003e\n\u003cli\u003eEnsure proper shield grounding practices are followed for transducer cables to prevent electrical noise interference.\u003c\/li\u003e\n\u003cli\u003eAlign the module firmly with the rack backplane connectors during installation to ensure proper electrical contact.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666869743979,"sku":"81545-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-81545-01-dual-relay-module-n1tbuvplzis_5006960d-3ff4-44a7-9102-76e1a5d90b6e.jpg?v=1765449582"},{"product_id":"bently-nevada-3300-35-12-01-01-00-00-six-channel-temperature-rtd-input-monitor","title":"Bently Nevada 3300\/35-12-01-01-00-00 Six-Channel Temperature RTD Input Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3300\/35-12-01-01-00-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 Series Six-Channel Temperature RTD Input Monitor\u003c\/strong\u003e engineered to provide continuous, on-line temperature monitoring for industrial machinery. This specific configuration accepts input signals from six 3-wire 100 ohm platinum RTD sensors across a full-scale range of 0 to 150 degC. It performs continuous signal conditioning, drives individual channel recorder outputs, and includes epoxy-sealed alarm relays for machine protection. Operating within the Bently Nevada 3300 system rack, the unit displays monitored temperatures on a 4-digit LCD screen and provides status indication via front-panel LEDs.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors six independent temperature channels using resistance temperature detector (RTD) inputs.\u003c\/li\u003e\n\u003cli\u003ePre-configured for 3-wire 100 ohm platinum RTD sensors with an alpha coefficient of 0.00392.\u003c\/li\u003e\n\u003cli\u003eFactory calibrated for a 0 to 150 degC full-scale operating range.\u003c\/li\u003e\n\u003cli\u003eEquipped with an epoxy-sealed dual alarm relay module for Alarm 1 and Alarm 2 contact outputs.\u003c\/li\u003e\n\u003cli\u003eProvides individual proportional recorder outputs (+4 to +20 mA default) for each channel.\u003c\/li\u003e\n\u003cli\u003eFeatures a front-panel 4-digit LCD display alongside OK, Alarm 1, Alarm 2, and Bypass status LEDs.\u003c\/li\u003e\n\u003cli\u003eSupports internal plug-in jumpers for configuring alarm delays, reset logic, and recorder output types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous temperature monitoring of machinery bearings, windings, and stator temperatures.\u003c\/li\u003e\n\u003cli\u003eOn-line RTD signal conditioning and alarm protection in Bently Nevada 3300 rack systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial monitoring applications requiring localized digital readout and dedicated relay outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrdering Code Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3300\/35\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSix-Channel Temperature RTD Input Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Full-scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 150 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Transducer Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ohm platinum (a = 0.00392) (3-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Alarm Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Safety Barriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/35-12-01-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSix-Channel Temperature RTD Input Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e6 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Type\u003c\/td\u003e\n\u003ctd\u003e3-wire 100 ohm platinum RTD (a = 0.00392)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Module\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Barrier Option\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 4 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-digit 7-segment non-multiplexing LCD with decimal point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Accuracy (+25 degC)\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-1 degC (+\/-1.8 degF) with tenths digit; +\/-1.5 degC (+\/-2.7 degF) without tenths digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 or 1 (user-programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Status Indicators\u003c\/td\u003e\n\u003ctd\u003eOK (green), Alarm 1 (red), Alarm 2 (red), Bypass (red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output Signal\u003c\/td\u003e\n\u003ctd\u003eUser-programmable: +4 to +20 mA, 0 to -10 Vdc, or +1 to +5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Accuracy (+4 to +20 mA)\u003c\/td\u003e\n\u003ctd\u003e+\/-1.8% of signal, +\/-0.09 mA offset (at +25 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Impedance\u003c\/td\u003e\n\u003ctd\u003e100 ohm (minimum load resistance 10 k ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Compliance\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc across load (0 to 600 ohm load for +4 to +20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Setpoint Adjustment\u003c\/td\u003e\n\u003ctd\u003eDigitally adjustable 0 to +500 degC (0 to +1000 degF), repeatability +\/-1 degC (+\/-1.8 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (+32 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirements\u003c\/td\u003e\n\u003ctd\u003eTwo rack positions (positions 3 through 12 in 3300 rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.8 kg (6.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Connector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input Connector\u003c\/td\u003e\n\u003ctd\u003eTerminal connections for 3-wire RTD sensor inputs (Channels 1 to 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output Connector\u003c\/td\u003e\n\u003ctd\u003eTerminal outputs for individual channel recorder signals (CH1-CH6: +, -S, COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Contact Connector\u003c\/td\u003e\n\u003ctd\u003eRelay output contacts for Alarm 1 and Alarm 2 (NC, ARM, NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module into two vacant positions of a 3300 rack (positions 3 through 12; positions 1 and 2 are reserved for Power Supply and System Monitor).\u003c\/li\u003e\n\u003cli\u003eLand 3-wire RTD sensor wiring directly onto the channel terminal connectors on the rear input assembly.\u003c\/li\u003e\n\u003cli\u003eConfigure internal plug-in jumpers behind the front panel to adjust settings such as Alarm Delays (1, 3, or 6 seconds), Latching\/Nonlatching reset modes, and Recorder Output types.\u003c\/li\u003e\n\u003cli\u003eUse the front-panel MODE, CHANNEL STEP, ALARM 1, and ALARM 2 pushbuttons to review monitored values and setpoint levels without interrupting monitoring operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE EMC Directive (Certificate of Conformity: 158710)\u003c\/li\u003e\n\u003cli\u003eCE Low Voltage Directive (Certificate of Conformity: 135300)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53698364965227,"sku":"3300\/35-12-01-01-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3300-35-12-01-01-00-00_003_1200x1200_0c20321e-8fb5-48fd-bf9e-6502c3dc2bff.jpg?v=1786368783"},{"product_id":"bently-nevada-model-330100-pn-102046-50-custom-proximitor","title":"Bently Nevada Model 330100 Pn.102046-50 Custom Proximitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e330100\u003c\/strong\u003e (P\/N \u003cstrong\u003e102046-50\u003c\/strong\u003e) is a Custom Proximitor designed for non-contact shaft vibration and axial position measurement in rotating machinery monitoring systems. The unit conditions radio frequency (RF) signals sent to a paired eddy current proximity probe to generate a DC voltage output proportional to static gap distance and an AC voltage output proportional to dynamic shaft vibration. Designed to operate with an 8 mm probe tip diameter and a 5-meter total system cable length, the device conditions analog transducer signals calibrated specifically for AISI 4140 target material at a scale factor of 200 mV\/mil.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePre-calibrated for AISI 4140 target material with a scale factor of 200 mV\/mil\u003c\/li\u003e\n\u003cli\u003eCompatible with 8 mm probe tip diameter proximity sensors\u003c\/li\u003e\n\u003cli\u003eMatched for 5-meter total system cable length configuration\u003c\/li\u003e\n\u003cli\u003eDirect terminal connections for power, signal ground, and output lines\u003c\/li\u003e\n\u003cli\u003eCSA certified for hazardous location installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial steam turbine and gas turbine shaft vibration monitoring\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressor shaft position and radial displacement tracking\u003c\/li\u003e\n\u003cli\u003eBoiler feed pump shaft displacement and thrust position measurement\u003c\/li\u003e\n\u003cli\u003eHigh-speed industrial gearbox proximity transducer signal processing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 Series Custom Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e102046-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDresser Rand TSE 060-987-169 Custom Proximitor Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330100\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e102046-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer Part Number\u003c\/td\u003e\n\u003ctd\u003eDresser Rand TSE 060-987-169\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage (Vt)\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cable Length\u003c\/td\u003e\n\u003ctd\u003e5 METRE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObserved Material\u003c\/td\u003e\n\u003ctd\u003eAISI 4140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Classifications\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 1 Exia, Groups A, B, C, D; Class I, Division 2, Groups A, B, C \u0026amp; D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Code\u003c\/td\u003e\n\u003ctd\u003eT4A (Ta = 100 degC), T5 (Ta = 65 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eSignal Output Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon \/ Circuit Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVt\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage (-24 Vdc Input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure power supply wiring matches the specified -24 Vdc operating voltage.\u003c\/li\u003e\n\u003cli\u003eInstall in accordance with installation drawing DWG CA22000 for hazardous location compliance.\u003c\/li\u003e\n\u003cli\u003eMaintain clean, tight connections on terminal block terminals labeled OUT, COM, and Vt.\u003c\/li\u003e\n\u003cli\u003eEnsure the physical cable length matches the 5-meter system rating for optimal calibration accuracy.\u003c\/li\u003e\n\u003cli\u003eVerify target material compatibility with AISI 4140 to prevent scale factor error.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA NRTL\/C Class I, Division 1 Exia, Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003eCSA NRTL\/C Class I, Division 2, Groups A, B, C \u0026amp; D\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53740732842347,"sku":"102046-50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/102046-50_004_1200x1200_f05d1eae-6480-4909-886a-8b31d760bc98.jpg?v=1787133954"},{"product_id":"bently-nevada-3300-12-01-20-00-ac-power-supply","title":"Bently Nevada 3300\/12-01-20-00 AC Power Supply","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3300\/12-01-20-00\u003c\/strong\u003e is an AC power supply designed for the 3300 machinery monitoring system. It provides regulated power for up to 12 monitors and their associated transducers within a single 3300 rack.\u003c\/p\u003e\n\u003cp\u003eThe power supply installs in position 1, the left-most rack position next to the System Monitor. The 3300\/12-01-20-00 configuration accepts 95-125 Vac single-phase input at 50-60 Hz, with a maximum input current of 1.0 A.\u003c\/p\u003e\n\u003cp\u003eThe power supply converts the incoming AC supply into DC voltages required by the installed monitoring modules. Transducer power can be configured for -24 Vdc or -18 Vdc, depending on the installed transducer system.\u003c\/p\u003e\n\u003cp\u003eThis configuration includes the standard Power Input Module and does not specify an agency approval option. A line noise filter is included as standard in the 3300\/12 AC Power Supply.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRegulated power supply for Bently Nevada 3300 monitoring racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupplies up to 12 monitors and associated transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e95-125 Vac single-phase input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50-60 Hz input frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1.0 A maximum input current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard Power Input Module configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser-programmable -24 Vdc or -18 Vdc transducer supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard line noise filter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated OK relay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOccupies one rack position\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstalls in position 1 of the 3300 rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 3300 machinery monitoring racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower distribution for installed vibration monitoring modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransducer power supply within 3300 monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance and replacement of existing 3300\/12 AC power supplies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery protection systems using 3300 or compatible transducer configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3300\/12\u003c\/td\u003e\n\u003ctd\u003eAC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e95-125 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eStandard Power Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eAgency approval not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/12-01-20-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 12 monitors and associated transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Position\u003c\/td\u003e\n\u003ctd\u003ePosition 1, left-most position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirement\u003c\/td\u003e\n\u003ctd\u003eOne rack position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg (2.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eElectrical Input\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e95-125 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower-up Surge\u003c\/td\u003e\n\u003ctd\u003e26 A peak or 12 A rms for one cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Rating\u003c\/td\u003e\n\u003ctd\u003e1.5 A slow blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eTransducer Power Output\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Option 1\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc, +0%, -2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Option 2\u003c\/td\u003e\n\u003ctd\u003e-18 Vdc, +1%, -2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eUser-programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003ePer-channel overload protection on individual monitor circuit boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOK Relay\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003ePower Supply Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSPDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing\u003c\/td\u003e\n\u003ctd\u003eHermetically sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd\u003eNormally energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e5 A at 28 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e5 A at 120 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e3 A at 220 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles minimum at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Power Input\u003c\/td\u003e\n\u003ctd\u003e95-125 Vac supply connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input Module\u003c\/td\u003e\n\u003ctd\u003eProvides primary power interface and OK relay connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK Relay Terminals\u003c\/td\u003e\n\u003ctd\u003eExternal annunciator or status signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Connection\u003c\/td\u003e\n\u003ctd\u003eInternal power distribution to installed monitor modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the complete model number 3300\/12-01-20-00 before replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that the rack requires the 95-125 Vac input configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolate primary power before removing or installing the power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the unit only in position 1 of the 3300 rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the Power Input Module and mating connections before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the required -24 Vdc or -18 Vdc transducer supply configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm primary power wiring and fuse selection before energizing the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck OK relay operation after power-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify normal monitor and transducer operation before returning the rack to service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCommissioning Recommendations\u003c\/h3\u003e\n\u003cp\u003eConfirm that the incoming AC supply remains within the specified 95-125 Vac range before energizing the rack.\u003c\/p\u003e\n\u003cp\u003eVerify the selected transducer output voltage before connecting or operating field transducers.\u003c\/p\u003e\n\u003cp\u003eCheck the OK relay state and monitor status after initial power-up.\u003c\/p\u003e\n\u003cp\u003eWhere machinery protection depends on the rack, external annunciation from the OK relay should be considered as part of the system design.\u003c\/p\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cp\u003eThe complete catalog number should be matched during replacement because the 3300\/12 ordering code defines input voltage, Power Input Module configuration, and agency approval.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3300\/12-01-20-00\u003c\/strong\u003e configuration uses the standard Power Input Module with 95-125 Vac input and no agency approval option.\u003c\/p\u003e\n\u003cp\u003eRecord the existing transducer supply configuration before removal because the -24 Vdc and -18 Vdc output selections are field-programmable.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53754446709099,"sku":"3300\/12-01-20-00","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3300-12-01-20-00_003_1200x1200_8d10a483-e076-427f-939e-08ad601e7156.jpg?v=1787375207"},{"product_id":"bently-nevada-79492-01-3300-35-six-channel-rtd-temperature-monitor","title":"Bently Nevada 79492-01 3300\/35 Six-Channel RTD Temperature Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 79492-01\u003c\/strong\u003e is a 3300\/35 Six-Channel RTD Temperature Monitor designed for continuous temperature monitoring in Bently Nevada 3300 systems.\u003c\/p\u003e\n\u003cp\u003eThe monitor provides six independent temperature channels and accepts up to six resistance temperature detector inputs. The identified 79492-01 configuration uses 3-wire 100 ohm platinum RTDs with an alpha coefficient of 0.00392.\u003c\/p\u003e\n\u003cp\u003eThis configuration has a full-scale measurement range of 0 to 300 degF. Each channel provides independent temperature indication and alarm processing for machinery monitoring applications.\u003c\/p\u003e\n\u003cp\u003eThe front panel includes a four-digit LCD for measured temperature, channel status, alarms, bypass status, and diagnostic information. Individual recorder outputs are available for all six channels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSix independent temperature monitoring channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for Bently Nevada 3300 machinery monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3300\/35 RTD input configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSix RTD input capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3-wire 100 ohm platinum RTD input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlatinum alpha coefficient of 0.00392\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to 300 degF configured full-scale range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo independently configurable alarm levels per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront-panel LCD temperature and status indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndividual recorder output for each channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEpoxy-sealed alarm relay configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront-panel controls for channel and alarm information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBearing temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery temperature protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor and generator temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotating equipment condition monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-point RTD temperature measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement of existing 79492-01 temperature monitor assemblies in 3300 systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3300\/35 Six-Channel Temperature RTD Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Range Option\u003c\/td\u003e\n\u003ctd\u003e02 - 0 to 300 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input Option\u003c\/td\u003e\n\u003ctd\u003e01 - 100 ohm platinum, alpha 0.00392, 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Option\u003c\/td\u003e\n\u003ctd\u003e01 - Epoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e01 - CSA\/NRTL\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Barrier Option\u003c\/td\u003e\n\u003ctd\u003e00 - None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e79492-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300\/35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSix-Channel RTD Temperature Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eRTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space Requirement\u003c\/td\u003e\n\u003ctd\u003e2 rack positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.8 kg (6.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eRTD Input\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigured Sensor Type\u003c\/td\u003e\n\u003ctd\u003e100 ohm platinum RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlpha Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Configuration\u003c\/td\u003e\n\u003ctd\u003e3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigured Full-scale Range\u003c\/td\u003e\n\u003ctd\u003e0 to 300 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Number of Inputs\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Conditioning\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Accuracy with Tenth Digit\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-1 degC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Accuracy without Tenth Digit\u003c\/td\u003e\n\u003ctd\u003e+\/-1.5 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Reference Temperature\u003c\/td\u003e\n\u003ctd\u003e+25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecorder Outputs\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Recorder Outputs\u003c\/td\u003e\n\u003ctd\u003e6, one per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Current Output\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Voltage Output\u003c\/td\u003e\n\u003ctd\u003e+1 to +5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Voltage Output\u003c\/td\u003e\n\u003ctd\u003e0 to -10 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Impedance\u003c\/td\u003e\n\u003ctd\u003e100 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Voltage-output Load\u003c\/td\u003e\n\u003ctd\u003e10 kohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA Load Resistance\u003c\/td\u003e\n\u003ctd\u003e0 to 600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAlarm Functions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Levels\u003c\/td\u003e\n\u003ctd\u003eAlarm 1 and Alarm 2 per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Setpoint Range\u003c\/td\u003e\n\u003ctd\u003e0 to +500 degC (0 to +1000 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Setpoint Resolution\u003c\/td\u003e\n\u003ctd\u003e1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Repeatability\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-1 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm 1 Function\u003c\/td\u003e\n\u003ctd\u003eOver-alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm 2 Function\u003c\/td\u003e\n\u003ctd\u003eUser-programmable over- or under-alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Configuration\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDisplay and Controls\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-digit LCD with decimal point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Modes\u003c\/td\u003e\n\u003ctd\u003eSCAN and HIGH READ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 or 1, user-programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eOK, Alarm 1, Alarm 2, Bypass and First Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Controls\u003c\/td\u003e\n\u003ctd\u003eAlarm 1, Alarm 2, Mode and Channel Step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK Indicator\u003c\/td\u003e\n\u003ctd\u003eGreen LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Indicators\u003c\/td\u003e\n\u003ctd\u003eAlarm 1 and Alarm 2 LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBypass Indicator\u003c\/td\u003e\n\u003ctd\u003eRed LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the part number 79492-01 before replacing an installed monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the existing system uses the 3300\/35 RTD temperature-monitor architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the required RTD type and configured full-scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecord existing alarm, recorder-output, and bypass settings before removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolate applicable system circuits before disconnecting the installed monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the RTD field wiring before reconnecting all six channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the monitor in the correct 3300 rack positions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck monitor calibration after installing a spare unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify all six temperature channels before returning the system to normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe 79492-01 configuration uses 3-wire 100 ohm platinum RTDs with an alpha coefficient of 0.00392.\u003c\/p\u003e\n\u003cp\u003eRecorder outputs can be configured for +4 to +20 mA, +1 to +5 Vdc, or 0 to -10 Vdc according to system requirements.\u003c\/p\u003e\n\u003cp\u003eAlarm 1 operates as an over-temperature alarm. Alarm 2 can be configured for either over-temperature or under-temperature operation.\u003c\/p\u003e\n\u003cp\u003eAlarm reset behavior, time delay, First Out functions, recorder behavior during NOT OK conditions, and display resolution are field-programmable options.\u003c\/p\u003e\n\u003ch3\u003eCommissioning Recommendations\u003c\/h3\u003e\n\u003cp\u003eVerify each RTD channel independently after installation.\u003c\/p\u003e\n\u003cp\u003eCompare displayed temperatures with expected machine conditions before enabling alarm actions.\u003c\/p\u003e\n\u003cp\u003eCheck Alarm 1 and Alarm 2 setpoints for every active channel.\u003c\/p\u003e\n\u003cp\u003eVerify individual recorder outputs if the monitor is connected to external recording or control equipment.\u003c\/p\u003e\n\u003cp\u003eA replacement monitor should be checked and recalibrated as necessary before normal service.\u003c\/p\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e79492-01\u003c\/strong\u003e should be matched to the existing 3300\/35 monitor configuration rather than selected only by the Six-Channel Temperature Monitor description.\u003c\/p\u003e\n\u003cp\u003eVerify the RTD type, measurement range, relay configuration, agency option, and safety-barrier configuration before replacement.\u003c\/p\u003e\n\u003cp\u003eRecord field-programmable settings before removing the existing unit. This reduces commissioning work and helps preserve the original machinery protection strategy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53754466500971,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/79492-01_001_1200x1200_860f9da0-a13b-4d09-a7da-514a6c212d58.png?v=1787376826"},{"product_id":"bently-nevada-3300-16-11-01-02-03-02-00-pwa-86739-01-dual-vibration-monitor","title":"Bently Nevada 3300\/16-11-01-02-03-02-00 PWA 86739-01 Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3300\/16-11-01-02-03-02-00\u003c\/strong\u003e is a dual vibration monitor for the Bently Nevada 3300 machinery monitoring system. The unit uses the original \u003cstrong\u003ePWA 86739-01\u003c\/strong\u003e main circuit board.\u003c\/p\u003e\n\u003cp\u003eThe monitor continuously measures two independent radial vibration channels, identified as Channel A and Channel B. It also monitors proximity probe gap voltage for each channel.\u003c\/p\u003e\n\u003cp\u003eThis configuration has a vibration full-scale range of \u003cstrong\u003e0 to 100 um peak-to-peak\u003c\/strong\u003e. The transducer input option is designed for 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensors with a \u003cstrong\u003e200 mV\/mil\u003c\/strong\u003e scale factor.\u003c\/p\u003e\n\u003cp\u003eThe unit includes a hermetically sealed alarm relay option and internal safety barriers. Alert and Danger functions provide independent machinery protection setpoints for the monitored channels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDual-channel radial vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndependent Channel A and Channel B measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe gap voltage monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to 100 um peak-to-peak vibration range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 3300 8 mm Proximitor Sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 3300 XL 8 mm Proximitor Sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 7200 5 mm and 8 mm Proximitor Sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e200 mV\/mil transducer input scale factor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHermetically sealed alarm relay configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal safety barrier configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuffered transducer outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlert and Danger alarm functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFirst Out, bypass, self-test, and recorder-output functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOriginal PWA 86739-01 main board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRadial shaft vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft gap and position monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotating machinery protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine and compressor vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery condition monitoring using proximity probe systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement of existing 3300\/16 monitors with matching configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16 Dual Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA: Full-scale Range\u003c\/td\u003e\n\u003ctd\u003e11 - 0 to 100 um peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB: Transducer Input\u003c\/td\u003e\n\u003ctd\u003e01 - 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Scale Factor\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC: Alarm Relay\u003c\/td\u003e\n\u003ctd\u003e02 - Hermetically sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD: Agency Approval\u003c\/td\u003e\n\u003ctd\u003e03 - Exact catalog code retained; meaning not defined in supplied Rev. P manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE: Safety Barrier\u003c\/td\u003e\n\u003ctd\u003e02 - Internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF: Trip Multiply\u003c\/td\u003e\n\u003ctd\u003e00 - None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-11-01-02-03-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDual Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain PWA\u003c\/td\u003e\n\u003ctd\u003e86739-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWA Version\u003c\/td\u003e\n\u003ctd\u003eOriginal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eRadial vibration and probe gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Full-scale Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 um peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input\u003c\/td\u003e\n\u003ctd\u003e3300 8 mm, 3300 XL 8 mm, 7200 5 mm and 8 mm Proximitor Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Scale Factor\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay\u003c\/td\u003e\n\u003ctd\u003eHermetically sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Barrier\u003c\/td\u003e\n\u003ctd\u003eInternal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003e0 to -10 Vdc, +1 to +5 Vdc, or +4 to +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Outputs\u003c\/td\u003e\n\u003ctd\u003eFront-panel coaxial connectors and rear Signal Input Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMonitor Functions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadial Vibration\u003c\/td\u003e\n\u003ctd\u003eContinuous measurement of shaft dynamic motion for Channels A and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Gap\u003c\/td\u003e\n\u003ctd\u003eDisplays negative DC voltage proportional to probe-to-target gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlert Alarm\u003c\/td\u003e\n\u003ctd\u003eFirst-level vibration alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDanger Alarm\u003c\/td\u003e\n\u003ctd\u003eSecond-level vibration alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirst Out\u003c\/td\u003e\n\u003ctd\u003eIdentifies the first channel entering an alarm state when enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bypass\u003c\/td\u003e\n\u003ctd\u003eRemoves a selected channel from active monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDanger Bypass\u003c\/td\u003e\n\u003ctd\u003eInhibits Danger relay drive during maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Output\u003c\/td\u003e\n\u003ctd\u003eProvides transducer signals for external equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003eProvides output proportional to measured vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-Test\u003c\/td\u003e\n\u003ctd\u003ePower-up, cyclic, and user-invoked diagnostic testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePWA 86739-01 Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e86739-01\u003c\/strong\u003e is the original version of the 3300\/16 main PWA.\u003c\/p\u003e\n\u003cp\u003eIts programmable options are configured through jumpers on the main circuit board. These include First Out, alarm latching, Danger voting, vibration alarm delay, Gap Alarm, recorder clamping, corner frequency, recorder output, gap range, vibration range, transducer input, and Trip Multiply.\u003c\/p\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the complete catalog number before replacing the installed monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the installed board is PWA 86739-01 before changing jumper settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the Proximitor Sensor type and 200 mV\/mil scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecord Alert, Danger, gap, recorder, and bypass settings before removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower down the rack or inhibit rack alarms before removing the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify internal safety barrier wiring before reconnecting field circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck both vibration channels and gap readings after installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm Alert and Danger functions before returning the system to service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplacement Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePWA 86739-01 uses different jumper locations from later 135305-01 and 140720-01 boards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not copy jumper positions from later PWA revisions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMatch the full-scale range, transducer input, relay type, safety barrier, and Trip Multiply configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreserve the exact catalog number when sourcing a replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53754505658731,"sku":"3300\/16-11-01-02-03-02-00 86739-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3300-16-11-01-02-03-02-00-86739-01_001_1200x1200_c2ff11b8-49ea-4363-aef1-0c54ba0b54ba.png?v=1787379737"},{"product_id":"bently-nevada-87890-01-monitor-circuit-assembly-for-3300-03-system-monitor","title":"Bently Nevada 87890-01 Monitor Circuit Assembly for 3300\/03 System Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 87890-01\u003c\/strong\u003e is a Monitor Circuit Assembly used in the \u003cstrong\u003e3300\/03 System Monitor\u003c\/strong\u003e for Bently Nevada 3300 machinery monitoring racks.\u003c\/p\u003e\n\u003cp\u003eThe assembly forms part of the System Monitor electronics responsible for rack-level monitoring and control functions. The 3300\/03 architecture provides System Reset, Inhibit, OK, Trip Multiply, and Keyphasor-related functions within the 3300 monitoring system.\u003c\/p\u003e\n\u003cp\u003eThe System Monitor also coordinates the rack OK logic. Individual monitor OK relay drives feed the rack OK bus, while the System Monitor and Power Input Module determine the final OK relay state.\u003c\/p\u003e\n\u003cp\u003eWhen replacing an 87890-01 assembly, the complete 3300\/03 catalog configuration and any modification information should be identified before installation. Programmable options must match the original System Monitor configuration.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor Circuit Assembly for the Bently Nevada 3300\/03 System Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePart number 87890-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUsed within the 3300 machinery monitoring system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports rack-level System Monitor functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAssociated with System Reset and Inhibit functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaces with rack OK relay logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports Trip Multiply control functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAssociated with Keyphasor signal handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgrammable according to the installed 3300\/03 configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement configuration should match the original catalog and modification data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance of Bently Nevada 3300 monitoring racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRepair of 3300\/03 System Monitor assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack-level machinery protection system servicing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement of an existing 87890-01 circuit assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRestoration of System Monitor control and supervisory functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e87890-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMonitor Circuit Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Module\u003c\/td\u003e\n\u003ctd\u003e3300\/03 System Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable -VT Option\u003c\/td\u003e\n\u003ctd\u003e-18 Vdc or -24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Functions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Reset\u003c\/td\u003e\n\u003ctd\u003eRack-level reset contact function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Inhibit\u003c\/td\u003e\n\u003ctd\u003eProvides rack inhibit control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK Bus\u003c\/td\u003e\n\u003ctd\u003eReceives OK relay drive status from installed monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply\u003c\/td\u003e\n\u003ctd\u003eSupports external Trip Multiply contact functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyphasor\u003c\/td\u003e\n\u003ctd\u003eProvides Keyphasor-related signal and power functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Power-Up Inhibit\u003c\/td\u003e\n\u003ctd\u003eIncludes power-up inhibit timing within the System Monitor architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eElectrical References\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e+VRH\u003c\/td\u003e\n\u003ctd\u003e23.65 +\/- 6.35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+VRL\u003c\/td\u003e\n\u003ctd\u003e11.22 +\/- 3.09 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+7.5 V\u003c\/td\u003e\n\u003ctd\u003e7.5 +\/- 0.1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+5 V\u003c\/td\u003e\n\u003ctd\u003e5.00 +\/- 0.05 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREF\u003c\/td\u003e\n\u003ctd\u003e5.00 +\/- 0.009 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-7.5 V\u003c\/td\u003e\n\u003ctd\u003e-7.5 +\/- 0.1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-VT, -24 V Option\u003c\/td\u003e\n\u003ctd\u003e-23.75 +\/- 0.45 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-VT, -18 V Option\u003c\/td\u003e\n\u003ctd\u003e-17.9 +\/- 0.4 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Power-Up Inhibit Delay\u003c\/td\u003e\n\u003ctd\u003e2.1 +\/- 1 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKeyphasor Output\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-24 V Option\u003c\/td\u003e\n\u003ctd\u003e-23.2 to -24.2 V, short-circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-18 V Option\u003c\/td\u003e\n\u003ctd\u003e-17.4 to -18.3 V, short-circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the replacement part number \u003cstrong\u003e87890-01\u003c\/strong\u003e before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecord the complete 3300\/03 catalog number and modification number before removing the original assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMatch all programmable options to the existing System Monitor configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm that the System Monitor and Power Supply use the same -VT setting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect rack connectors and mating interfaces before installing the circuit assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply power and verify that the System Monitor reaches normal operation after the power-up inhibit period.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck rack OK logic and Keyphasor functions before returning the monitoring system to service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplacement Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e87890-01 is the Monitor Circuit Assembly, not the complete 3300\/03 System Monitor.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe Front Panel Assembly is listed separately in the Bently Nevada spare-parts structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement orders should identify the complete 3300\/03 catalog number together with 87890-01.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModified monitors should also be identified by their modification number.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53754751123819,"sku":"87890-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/87890-01-3300-03_003_1200x1200_213c3ee7-6044-4791-9216-813f14e9dc3e.png?v=1787393550"},{"product_id":"bently-nevada-3300-16-02-01-01-01-00-00-xy-gap-dual-vibration-monitor","title":"Bently Nevada 3300\/16-02-01-01-01-00-00 XY\/GAP Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3300\/16-02-01-01-01-00-00\u003c\/strong\u003e is an XY\/GAP Dual Vibration Monitor designed for two-channel radial vibration and shaft position monitoring in Bently Nevada 3300 systems.\u003c\/p\u003e\n\u003cp\u003eThe monitor accepts two proximity probe and Proximitor Sensor inputs. This configuration uses a \u003cstrong\u003e0 to 5 mil peak-to-peak\u003c\/strong\u003e vibration range and is designed for 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensors with a \u003cstrong\u003e200 mV\/mil\u003c\/strong\u003e scale factor.\u003c\/p\u003e\n\u003cp\u003eThe unit provides independent vibration measurement for Channel A and Channel B. Probe gap is also monitored to indicate average shaft position relative to the proximity probes.\u003c\/p\u003e\n\u003cp\u003eThis configuration includes an epoxy-sealed alarm relay, CSA\/NRTL\/C agency approval, no safety barriers, and no Trip Multiply option.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTwo independent radial vibration channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAverage shaft position and probe gap monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to 5 mil peak-to-peak full-scale vibration range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e200 mV\/mil transducer sensitivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 3300 8 mm Proximitor Sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 3300 XL 8 mm Proximitor Sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 7200 5 mm and 8 mm Proximitor Sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndependent Alert and Danger alarm functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Alert capability for both channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEpoxy-sealed alarm relay configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndividual recorder outputs for both channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront and rear buffered transducer outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCSA\/NRTL\/C approval configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo safety barrier option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo Trip Multiply option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRadial shaft vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft position and probe gap monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotating machinery protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-channel proximity probe monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery condition monitoring using 3300 proximity systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement of matching 3300\/16 XY\/GAP monitor configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16 XY\/GAP Dual Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA: Full-scale Range\u003c\/td\u003e\n\u003ctd\u003e02 - 0 to 5 mils peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB: Transducer Input\u003c\/td\u003e\n\u003ctd\u003e01 - 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Sensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC: Alarm Relay\u003c\/td\u003e\n\u003ctd\u003e01 - Epoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD: Agency Approval\u003c\/td\u003e\n\u003ctd\u003e01 - CSA\/NRTL\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE: Safety Barrier\u003c\/td\u003e\n\u003ctd\u003e00 - None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF: Trip Multiply\u003c\/td\u003e\n\u003ctd\u003e00 - None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-02-01-01-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eXY\/GAP Dual Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Functions\u003c\/td\u003e\n\u003ctd\u003eRadial vibration and average shaft position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Inputs\u003c\/td\u003e\n\u003ctd\u003eOne or two proximity probe signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Range\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mil peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Barrier\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space\u003c\/td\u003e\n\u003ctd\u003e1 rack position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg (2.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy at +25 degC\u003c\/td\u003e\n\u003ctd\u003e+\/-0.33% of full-scale typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Accuracy Error\u003c\/td\u003e\n\u003ctd\u003e+\/-1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response Option\u003c\/td\u003e\n\u003ctd\u003e4 to 4,000 Hz or 1 to 600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Setpoint Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100% of full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Repeatability\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-0.39% of full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGap Alarm Delay\u003c\/td\u003e\n\u003ctd\u003e6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecorder Outputs\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Output 1\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Output 2\u003c\/td\u003e\n\u003ctd\u003e0 to -10 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Output 3\u003c\/td\u003e\n\u003ctd\u003e+1 to +5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs per Channel\u003c\/td\u003e\n\u003ctd\u003e1 individual recorder output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Impedance\u003c\/td\u003e\n\u003ctd\u003e100 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Resistance\u003c\/td\u003e\n\u003ctd\u003e10 kohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA Load Resistance\u003c\/td\u003e\n\u003ctd\u003e0 to 600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBuffered Outputs\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Output\u003c\/td\u003e\n\u003ctd\u003eOne coaxial connector per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Output\u003c\/td\u003e\n\u003ctd\u003eOne terminal connection per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e100 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the complete catalog number before replacing the installed monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the existing proximity system uses a 200 mV\/mil transducer configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify compatibility with the installed 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecord existing Alert, Danger, gap, recorder-output, and bypass settings before removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the rack alarm state before removing or installing the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify Channel A and Channel B probe signals after installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck vibration, gap, Alert, Danger, and recorder outputs before returning the rack to service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplacement Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMatch the complete \u003cstrong\u003e3300\/16-02-01-01-01-00-00\u003c\/strong\u003e configuration when sourcing a replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not substitute another 3300\/16 solely because the front panel appears identical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFull-scale range, transducer input, relay option, agency approval, safety barrier, and Trip Multiply options must be checked.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53754819346795,"sku":"3300\/16-02-01-01-01-00-00","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3300-16-02-01-01-01-00-00_001_1200x1200_21e56629-5100-4346-95fd-acd14f0e572a.png?v=1787394516"},{"product_id":"bently-nevada-3300-50-02-01-00-00-tachometer-monitor","title":"Bently Nevada 3300\/50-02-01-00-00 Tachometer Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3300\/50-02-01-00-00\u003c\/strong\u003e is a Zero Speed Tachometer Monitor designed for critical machinery rotative speed and condition monitoring within the 3300 System platform. Operating as a single-channel monitoring module, it accepts dual transducer inputs and utilizes internal voting logic to prevent false trip indications caused by a single sensor failure. The \u003cstrong\u003e3300\/50-02-01-00-00\u003c\/strong\u003e variant is configured specifically as a Zero Speed Tachometer (Type Option 02) with Epoxy Relay outputs (Alert Relay Option 01), CSA\/NRTL\/C agency approvals (Option 00 for standard applications without specialized certifications), and no internal safety barriers (Option 00).\u003c\/p\u003e\n\u003cp\u003eThe front panel features dual 5-digit LCD displays that output shaft rotative speed in RPM alongside probe gap voltage, providing operator visibility into operating parameters and transducer health. It includes BNC buffered transducer outputs on the front panel for diagnostic equipment hookup, along with user-programmable proportional analog outputs (current or voltage) on the rear terminal strip for plant recording systems.\u003c\/p\u003e\n\u003cp\u003eWhile providing continuous monitoring, Alert status, and proportional analog feedback for data logging, the \u003cstrong\u003e3300\/50-02-01-00-00\u003c\/strong\u003e tachometer is designed strictly for machinery condition monitoring and annunciation. It is not engineered for independent use as an emergency overspeed protection or speed control system.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Transducer Input Voting:\u003c\/strong\u003e Accepts inputs from two independent transducers with internal voting logic to maintain system integrity and minimize false alarms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Speed Detection:\u003c\/strong\u003e Configured specifically for zero speed monitoring, functioning reliably at operating thresholds below 100 RPM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Front Panel Display:\u003c\/strong\u003e Features an 84 mm x 38 mm LCD displaying 5-digit RPM values, transducer gap voltage, and operational status indicators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuffered Diagnostic Outputs:\u003c\/strong\u003e Provides front-panel coaxial BNC connectors for direct, short-circuit-protected signal access during field troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Proportional Outputs:\u003c\/strong\u003e Delivers configurable rear terminal recorder outputs (+4 to +20 mA, 0 to -10 Vdc, or +1 to +5 Vdc) proportional to shaft rotative speed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEpoxy Alarm Relays:\u003c\/strong\u003e Includes dual epoxy-sealed relay drives for field-adjustable Alert 1 and Alert 2 annunciation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbomachinery Rotative Speed Monitoring:\u003c\/strong\u003e Continuous speed and zero speed state measurement for steam, gas, and industrial turbines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotating Equipment Machinery Protection:\u003c\/strong\u003e Shaft speed tracking on high-power compressors, industrial gearboxes, and large motor drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Speed Turning Gear Integration:\u003c\/strong\u003e Zero speed status verification for engaging turning gear systems on power generation units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3300\/50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTachometer Monitor Base Model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZero Speed Tachometer Type Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy Relay Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option (Not Required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Barrier Option (None)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e3300\/50 Tachometer Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Part Number\u003c\/td\u003e\n\u003ctd\u003e3300\/50-02-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 Watts (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Display Size\u003c\/td\u003e\n\u003ctd\u003e84 mm x 38 mm (0.33 in x 0.15 in) LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eSignal \u0026amp; Transducer Inputs\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Transducers\u003c\/td\u003e\n\u003ctd\u003e3300, 7200, or 3000 Series Proximitor Probes; Magnetic Pickups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity\u003c\/td\u003e\n\u003ctd\u003eAccepts 2 transducer signals (Supports mixed input types)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Threshold Range\u003c\/td\u003e\n\u003ctd\u003eUser-selectable from 0 to -18 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Threshold Range\u003c\/td\u003e\n\u003ctd\u003e10 Hz (600 rpm for 1 event\/rev) to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHysteresis Range\u003c\/td\u003e\n\u003ctd\u003eUser-selectable from 0.2 to 2.0 Volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvents per Revolution Option\u003c\/td\u003e\n\u003ctd\u003eNumerator: 1 to 255 \/ Denominator: 1 to 255 (Num\/Den \u0026gt;= 0.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Duty Cycle\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePerformance Ranges \u0026amp; Accuracy\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft Rotative Speed Range\u003c\/td\u003e\n\u003ctd\u003e1 to 99,999 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRotor Acceleration Range\u003c\/td\u003e\n\u003ctd\u003e-9,999 to 9,999 RPM\/MIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Speed Operating Threshold\u003c\/td\u003e\n\u003ctd\u003eBelow 100 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Display Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin +1 RPM (at +25 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceleration Display Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin 20 RPM\/MIN (at +25 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e+-1 RPM \/ +-1 RPM\/MIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOutputs \u0026amp; Alarms\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output Options\u003c\/td\u003e\n\u003ctd\u003eUser-programmable: +4 to +20 mA, 0 to -10 Vdc, or +1 to +5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance (Voltage)\u003c\/td\u003e\n\u003ctd\u003e100 Ohm (Minimum load resistance 10 kOhm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Compliance (Current)\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc across load (Load resistance 0 to 600 Ohm at +4 to +20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Transducer Outputs\u003c\/td\u003e\n\u003ctd\u003e1 coaxial BNC connector per transducer on front panel (Short-circuit protected, 100 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc or -18 Vdc (User-programmable in power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Setpoints\u003c\/td\u003e\n\u003ctd\u003eDigitally adjustable from 0 to 100% full-scale; nonvolatile memory storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Configurations\u003c\/td\u003e\n\u003ctd\u003eDual Epoxy Relays installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Time Delays\u003c\/td\u003e\n\u003ctd\u003eTachometer\/Acceleration: 1 sec or 3 valid triggers; Zero Speed (\u0026lt;100 RPM): 3 valid triggers (1 min max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental \u0026amp; Mechanical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (+32 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirements\u003c\/td\u003e\n\u003ctd\u003e1 rack position (Any position except 1 and 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer A Input Terminals\u003c\/td\u003e\n\u003ctd\u003eTerminal connections for Channel A Proximitor probe or magnetic pickup signal wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer B Input Terminals\u003c\/td\u003e\n\u003ctd\u003eTerminal connections for Channel B Proximitor probe or magnetic pickup signal wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Recorder Output Terminals\u003c\/td\u003e\n\u003ctd\u003eRear-panel terminal outputs for proportional voltage or current logging signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Alarm Relay Terminals\u003c\/td\u003e\n\u003ctd\u003eNormally Open (NO), Normally Closed (NC), and Common (ARM) relay contact terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Speed Enable Terminals\u003c\/td\u003e\n\u003ctd\u003eTerminal connection for external user-supplied contact closure to enable Zero Speed Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Transducers (A \u0026amp; B)\u003c\/td\u003e\n\u003ctd\u003eFront panel coaxial BNC jacks for raw signal monitoring with test equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify that the model number matches 3300\/50-02-01-00-00 and check the circuit board jumpers for correct input configuration before inserting the module into the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Placement:\u003c\/strong\u003e Install the monitor into any available slot in the 3300 system rack except slots 1 and 2, which are reserved exclusively for the Power Supply and System Monitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Connections:\u003c\/strong\u003e Connect transducer field wiring using 3-conductor shielded cable. Connect the cable shields to a single earth point ground to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Speed Enable Wiring:\u003c\/strong\u003e If utilizing the zero speed alarm feature, wire an external contact closure to the designated Zero Speed Enable terminals on the rear terminal strip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Verification:\u003c\/strong\u003e Ensure the rack power supply is configured for the correct transducer supply voltage (-24 Vdc or -18 Vdc) based on the proximity sensors installed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Configuration:\u003c\/strong\u003e Set onboard plug-in jumpers for input type (Proximitor or Magnetic Pickup), recorder output mode (+4 to +20 mA, 0 to -10 Vdc, or +1 to +5 Vdc), and alarm logic (latching or nonlatching) prior to commissioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreshold Setting:\u003c\/strong\u003e Set transducer thresholds using manual voltage settings (0 to -18 Vdc) or auto-threshold mode depending on operational speed requirements. Note that option 02 (Zero Speed) is shipped configured for manual threshold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Setpoint Adjustment:\u003c\/strong\u003e Adjust digitally stored Alert 1 and Alert 2 setpoints using the tamper-proof switches on the monitor circuit board and up\/down switches on the System Monitor front panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Considerations:\u003c\/strong\u003e Before replacing an existing module, record the physical jumper settings on the old PWAs to ensure identical operating parameters on the replacement unit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53756695904619,"sku":"3300\/50-02-01-00-00","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3300-50-02-01-00-00_001_1200x1200_eb665ad1-7a7c-4948-ba1b-47ab048c9427.jpg?v=1787488314"}],"url":"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-system-monitoring.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}