{"title":"Bently Nevada 3300 XL Extension Cables","description":"\u003cp\u003eBently Nevada 3300 XL Extension Cables are essential interconnect components designed to maintain signal integrity between the probe and the sensor. The architecture features a low-capacitance coaxial design with a FEP jacket, providing resistance to oil, chemicals, and mechanical abrasion. Technical characteristics include patented ClickLoc connectors that ensure secure, finger-tight connections and prevent accidental loosening due to machinery vibration. Functionally, these cables extend the reach of the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-xl-proximity-probe\"\u003e3300 XL proximity probe\u003c\/a\u003e to the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-xl-proximitor-sensor\"\u003e3300 XL Proximitor Sensor\u003c\/a\u003e without introducing phase shift or signal attenuation. Available in various lengths, they are calibrated to ensure the entire transducer system maintains a constant scale factor, which is vital for accurate vibration and position measurements in demanding industrial environments.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-330930-065-01-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-01-05 3300 NSv Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rugged, high-precision proximity transducer link engineered for the industry-leading\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 NSv\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity transducer system. Functioning as a high-integrity signal transmission path, this armored coaxial extension cable connects the specialized NSv proximity probe to the matching Proximitor sensor unit. Extreme operational environments—including oil and gas refineries, petrochemical processing plants, and critical aeroderivative gas turbine installations—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto deliver high-fidelity eddy current telemetry. The module maintains stable impedance profiles when routed through harsh confined spaces to track tight machinery clearances and small-shaft vibrations. By safeguarding low-voltage displacement signals from external radio frequency interference (RFI) and mechanical crushing, this cable guarantees precise data delivery. This continuous monitoring enables safety platforms to stop assets before catastrophic shaft misalignment or bearing wipe happens, effectively eliminating unprogrammed facility downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe ordering structure of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefines its exact mechanical shielding, transmission distance, and hazardous area safety compliance through a fixed modification format:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330930 (Base Model):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the 3300 NSv Coaxial Extension Cable platform tailored for narrow-gap and small-target proximity applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e065 (Cable Length Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfirms an exact physical cable length of 6.5 meters (21.3 feet), calibrated to specific electrical capacitance limits required by the driver module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01 (Connector Protector and Cable Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies an integrated flexible AISI 302 stainless steel armor sleeve outfitted with a high-durability Fluorinated Ethylene Propylene (FEP) outer jacket for maximum chemical and abrasion protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Agency Approval Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishes Multiple Approvals certification, qualifying the assembly for installation within explosive atmospheres and hazardous zones under ATEX and North American standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Benchmarks\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cstrong\u003eHardware Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cstrong\u003eCertified Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e330930-065-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e3300 NSv Proximity Transducer Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eComponent Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eArmored Coaxial Extension Cable with FEP Jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e6.5 meters (21.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eFlexible AISI 302 Stainless Steel (SST)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eOuter Insulation Jacket\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eFluorinated Ethylene Propylene (FEP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e0.220 Ohm\/meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCoaxial Shield Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e0.066 Ohm\/meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eNominal Cable Capacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e69.9 pF\/meter Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eMass Density (with Armor)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e64 g\/meter (0.7 oz\/foot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e-51 to +177 deg C Ambient Temperature Limits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eMinden, Nevada, USA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Telemetry \u0026amp; Mechanical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy must engineers select an exact cable length like the 6.5-meter option for proximity systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEddy current proximity transducer systems operate on strict total system electrical length calculations. The Proximitor sensor evaluates target distance by reading complex high-frequency impedance, which requires a fixed total capacitance. Modifying, cutting, or splicing the 330930-065-01-05 cable alters this baseline capacitance and corrupts the calibration curves, leading to invalid gap readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific protection does the 01 option provide over baseline unarmored coaxial cords?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 01 suffix configuration wraps the inner coaxial trace in flexible AISI 302 stainless steel armor, shielded further by a smooth FEP outer jacket. This setup prevents mechanical flattening or pinching from heavy cabinet doors and machine components while offering total chemical resistance against synthetic lubricants, hot oils, and corrosive industrial solvents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this extension cable maintain reliable telemetry under sub-zero or high-temperature steam environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The entire assembly utilizes advanced FEP insulation layers rated to maintain tight mechanical flexibility and zero dielectric breakdown across a wide operating thermal envelope of -51 to +177 deg C. This makes it highly stable for sub-sea cryogenic pumps as well as high-temperature gas turbine casing enclosures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection and Terminal Boot Alignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen joining the extension cable to the proximity probe lead, ensure the miniature coaxial connectors are clean, completely dry, and free of oily residues. Thread the connections together firmly by hand, avoiding excessive torque that can strip the micro-threads. Once joined, slide the factory connector protection sleeve or self-fusing silicone tape enclosure directly over the junction to seal it from moisture infiltration and prevent accidental grounding against nearby machine metalwork.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radii Rules and Conduit Routing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough the stainless steel armor casing provides excellent crushing protection, field technicians must adhere to standard minimum bend radius guidelines during routing. Avoid tight 90-degree creases or sharp structural edges that can kink the inner center conductor or alter the 69.9 pF\/meter nominal capacitance profile. Route the cable through dedicated, oil-tight flexible conduit paths, keeping the sensor wires separated from heavy high-voltage motor or generator supply lines to mitigate electro-magnetic cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Drainage and Structural Stress Relief:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen passing the 330930-065-01-05 cable through low-lying conduit runs, ensure the enclosure layout incorporates proper low-point drainage loops to prevent pooling fluid or condensation buildup from submerging the connections over long operating periods. Provide adequate strain relief loops at both the machine junction box and the 3500 rack entry plate, ensuring machine casing thermal expansion and high-frequency structural vibration do not pull or stress the cable terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515063147,"sku":"330930-065-01-05","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-01-05-nsv-extension-cable-phqpmgfntm3_c63fea36-3bf4-4a33-85bf-91600e72248c.jpg?v=1765440071"},{"product_id":"bently-nevada-330930-065-00-05-3300-xl-nsv-extension-cable","title":"Bently Nevada 330930-065-00-05 3300 XL NSv Extension Cable","description":"\u003ch3\u003e\n    Product Overview\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    The \u003cstrong\u003e330930-065-00-05 (3300 NSv)\u003c\/strong\u003e is a high-performance extension cable specifically engineered for the Bently Nevada 3300 XL NSv (Narrow Side View) Proximity Transducer System. This system is the industry standard for monitoring centrifugal air compressors, refrigeration compressors, and other rotating machinery with extremely tight installation constraints. As a critical link between the NSv probe and the Proximitor Sensor, the \u003cstrong\u003e330930-065-00-05\u003c\/strong\u003e ensures the transmission of high-fidelity displacement signals without impedance mismatch. Its 6.5-meter length is precisely tuned to provide the 200 mV\/mil (7.87 V\/mm) scale factor required for accurate radial vibration and axial position measurements on small-diameter shafts or targets.\n\u003c\/p\u003e\n\n\u003ch3\u003e\n    Suffix Configuration Breakdown\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    According to the official Datasheet 147385, the model \u003cstrong\u003e330930-065-00-05\u003c\/strong\u003e is defined by the following specific engineering options:\n\u003c\/p\u003e\n\n\u003cul class=\"list-paddingleft-2\"\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e065 (Cable Length):\u003c\/strong\u003e 6.5 meters (21.3 feet). This length is typically combined with a 0.5-meter probe to create a 7.0-meter total electrical system.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e00 (Connector Protector and Cable):\u003c\/strong\u003e Standard coaxial cable without stainless steel armor and without connector protectors. This version offers maximum flexibility for routing through dedicated conduit or internal machine housings.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e05 (Agency Approval):\u003c\/strong\u003e Multiple Approvals (ATEX, IECEx, CSA). This certification allows the cable to be used in intrinsically safe (I.S.) applications within hazardous areas globally.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\n    Technical Specifications\n\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003cthead\u003e\n        \u003ctr class=\"firstRow\"\u003e\n            \u003ctd\u003e\n                \u003cstrong\u003eAttribute\u003c\/strong\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n                \u003cstrong\u003eSpecification\u003c\/strong\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e330930-065-00-05\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eBently Nevada\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e3300 XL NSv Proximity Transducer\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eGold-plated Brass ClickLoc\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eJacket Material\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eFluorinated Ethylene Propylene (FEP)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e-52 deg C to +177 deg C (-62 deg F to +351 deg F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e-52 deg C to +177 deg C (-62 deg F to +351 deg F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\n    Engineering FAQs\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eWhy is the NSv extension cable different from standard 3300 XL cables?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    The NSv series is specifically designed for small targets and tight spaces. The electrical characteristics (inductance and capacitance) of the \u003cstrong\u003e330930\u003c\/strong\u003e cable are tuned to match the NSv probe's smaller coil. Mixing NSv cables with standard 8mm probes will result in incorrect vibration readings.\n\u003c\/p\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eWhat is the purpose of the ClickLoc connector?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    The ClickLoc connector is a patented design that prevents the connection between the probe and extension cable from loosening due to machinery vibration. The gold-plating ensures a low-resistance contact that is essential for maintaining the system's precision scale factor.\n\u003c\/p\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eCan I install this cable in an environment with turbine oil?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    Yes, the FEP jacket is highly resistant to turbine oil and most process chemicals. However, since this specific variant (\u003cstrong\u003e-00\u003c\/strong\u003e) does not have a connector protector, you must ensure the connection point is either sealed with the provided silicone tape or located in a dry area to prevent oil from entering the connector.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003e\n    Field Installation and Maintenance Directives\n\u003c\/h3\u003e\n\n\u003cul class=\"list-paddingleft-2\"\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eConnection Integrity:\u003c\/strong\u003e Before connecting the ClickLoc connectors, verify they are clean and dry. Use a lint-free cloth. Do not use pliers to tighten the connectors; they are designed to be finger-tightened until they \"click\" into a locked state.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eBend Radius Constraints:\u003c\/strong\u003e Maintain a minimum bend radius of \u003cstrong\u003e25.4 mm (1 inch)\u003c\/strong\u003e. Sharp bends can damage the internal coaxial shielding and dielectric, leading to \"signal spiking\" or a \"Not OK\" status on the 3500 monitor.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eProper Cable Support:\u003c\/strong\u003e Use high-quality cable ties or clamps to secure the cable every 1 to 2 feet. Ensure that the cable is not under tension at the connector ends. Vibration-induced stress on unsupported cables is a leading cause of premature failure in proximity systems.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eSystem Matching:\u003c\/strong\u003e Always verify that the total length of the probe plus the extension cable matches the configuration of the Proximitor Sensor (e.g., a 7m Proximitor requires a total cable length of 7m). The \u003cstrong\u003e330930-065\u003c\/strong\u003e is part of a 7.0-meter system when used with a 0.5-meter probe.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516275563,"sku":"330930-065-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-00-05-3300-xl-nsv-extension-cable-ullgkoscfm2_2e5685e9-33f6-4078-b646-4488fbee5f5e.jpg?v=1765440087"},{"product_id":"330930-065-00-cn-bently-nevada-3300-nsv-extension-cable","title":"330930-065-00-CN | Bently Nevada | 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3300 NSv Extension Cable\u003c\/strong\u003e provides vital electrical connection and signal path routing within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This specialized coaxial line interfaces between a non-contacting \u003cstrong\u003e3300 NSv\u003c\/strong\u003e proximity probe and its matching \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e to accurately relay eddy-current displacement signals. The \u003cstrong\u003e3300 XL NSv\u003c\/strong\u003e system is specifically intended for compact machinery applications, including centrifugal process air compressors, refrigeration compressors, and high-density installations exhibiting narrow side-view or counterbore clearances where standard systems face space constraints.\u003c\/p\u003e\n\u003cp\u003eThis specific product number \u003cstrong\u003e330930-065-00-CN\u003c\/strong\u003e designates a 6.5-metre layout variant built without defensive stainless steel armor plating, featuring hazardous area certification compliant with specialized regulatory standards for the China regional market. To maintain robust signal path integrity without physical shifting, the hardware features integrated gold-plated brass \u003cstrong\u003eClickLoc\u003c\/strong\u003e coaxial connectors on both terminal points that click-lock securely to prevent connections from loosening under sustained machine resonance. Utilizing a tailored 75-ohm impedance profile coupled with fluoroethylene propylene insulation, this component acts as a highly stable data transmission channel for precise mechanical vibration loops within safety and critical asset-monitoring infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Coaxial Connectors:\u003c\/strong\u003e Uses premium gold-plated brass hardware that positive-locks into place, ensuring continuous contact and preventing separation in high-vibration fields.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Grade FEP Insulation:\u003c\/strong\u003e Formulated with fluoroethylene propylene shielding to provide superior chemical and thermal resilience within challenging industrial oil and gas environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched System Impedance:\u003c\/strong\u003e Features an engineered 75-ohm characteristic design that matches the baseline requirements of the proximity probe to protect signal linearity across the loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Temperature Stability:\u003c\/strong\u003e Rated to withstand demanding environmental swings without altering electrical capacitance or inducing scale-factor drifts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors, process gas machinery, and refrigeration compression units.\u003c\/li\u003e\n\u003cli\u003eHigh-density rotating machinery instrumentation featuring tight physical constraints or narrow shaft targets smaller than 51 mm.\u003c\/li\u003e\n\u003cli\u003eMachinery monitoring networks measuring radial vibration, axial thrust positioning, or zero-speed tachometer inputs within hazardous industrial zones requiring localized country-specific compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330930\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-065\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Length Option: 6.5 metres (21.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector and Cable Option: Without stainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: Approvals country specific (China Approvals covering CCC\/NEPSI requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtension Cable Impedance\u003c\/td\u003e\n\u003ctd\u003e75 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCenter Conductor DC Resistance\u003c\/td\u003e\n\u003ctd\u003e0.220 ohms\/m (0.067 ohms\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eShield DC Resistance\u003c\/td\u003e\n\u003ctd\u003e0.066 ohms\/m (0.020 ohms\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +177 Celsius (-60 Fahrenheit to +351 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +177 Celsius (-60 Fahrenheit to +351 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtension Cable Material\u003c\/td\u003e\n\u003ctd\u003eCoaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eConnector Material\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eClickLoc miniature coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e6.5 metres (21.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Rated Tensile Strength\u003c\/td\u003e\n\u003ctd\u003e220 N (50 lb) at lead-to-extension cable connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCable Weight (Typical)\u003c\/td\u003e\n\u003ctd\u003e45 g\/m (0.5 oz\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Length Matching:\u003c\/strong\u003e Ensure that the combined physical length of your chosen extension cable and proximity probe equals the pre-calibrated baseline of the associated Proximitor Sensor (typically 5 or 7 meters total system length).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Care and Protection:\u003c\/strong\u003e Keep the miniature ClickLoc terminals clear of grease, solvents, and ambient dust before clicking them shut. It is recommended to apply a connector protector or wrap the joint in specialized silicone tape to block industrial moisture entry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid Turbine Oil Submersion:\u003c\/strong\u003e Do not deploy standard silicone-taped connections in internal machinery zones where the junctions are continuously exposed to moving turbine lubricating fluids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Constraints:\u003c\/strong\u003e Maintain a clean routing path that adheres strictly to the minimum bend constraint of 25.4 mm to prevent kinks, shielding cracks, or conductor attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing Separation:\u003c\/strong\u003e Separate the sensor signal line from adjacent high-voltage or variable-frequency drive power conduits to minimize stray electromagnetic or electrostatic background noise cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Authorized under option code -CN to cover specialized NEPSI\/CCC requirements for installation in hazardous industrial zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e Incorporates underlying ATEX\/IECEx hazardous area markings and rating frameworks on the product nameplate as applicable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the -CN suffix indicate for this proximity extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -CN suffix indicates a specialized regional approval variant tailored for the China market. It ensures compliance with mandatory CCC and NEPSI hazardous area safety standards while maintaining core alignment with international ATEX\/IECEx parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unarmored cable version be substituted directly into a layout requiring stainless steel armor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe underlying electrical properties are identical, but this model lacks the physical armor spiral shroud. If your application paths leave the cable bare to falling debris or sharp metal edges, an armored variant or a standalone protective conduit path is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the combined length of my probe and extension cable exceeds the calibrated sensor specification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsing unmatched total system lengths will alter the baseline electrical capacitance and inductance properties of the instrumentation loop. This skews the Average Scale Factor, leading to inaccurate machine displacement and vibration readings.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308554091,"sku":"330930-065-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-065-00-CN-eogtlymqjy4_3c3a5929-1782-4ede-90cf-27f4c6f5cbc8.jpg?v=1765520759"},{"product_id":"bently-nevada-330190-045-00-00-3300-xl-extended-temperature-range-etr-extension-cable","title":"Bently Nevada 330190-045-00-00  | 3300 XL Extended Temperature Range (ETR) Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330190-045-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL Extended Temperature Range (ETR) extension cable designed for vibration monitoring systems operating in thermally demanding industrial environments. It is commonly used in turbines, compressors, and process machinery where stable signal transmission must be maintained under elevated temperature conditions.\u003c\/p\u003e\n\u003cp\u003eThis cable supports reliable data transfer between proximity probes and monitoring modules while minimizing signal drift caused by thermal stress. It is applied in power generation, oil and gas, and heavy industrial systems where temperature stability directly affects machine protection accuracy.\u003c\/p\u003e\n\u003cp\u003eThe 4.5 meter configuration provides flexible routing in compact and mid-range machinery installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330190\u003c\/td\u003e\n\u003ctd\u003e3300 XL ETR extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e045\u003c\/td\u003e\n\u003ctd\u003e4.5 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo additional cable option required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines cable length and configuration level within the ETR extension cable family.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-045-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended temperature range extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eTriaxial ETR design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eHigh temperature industrial systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ETR cable design maintains stable electrical characteristics under elevated temperature conditions where standard extension cables may experience signal drift or insulation degradation.\u003c\/p\u003e\n\u003cp\u003eTriaxial construction ensures low-noise signal transmission and stable impedance performance, which is critical for accurate vibration monitoring in rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThe cable is optimized for integration in high-temperature zones such as turbine casings and compressor housings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and high-temperature industrial machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of ETR design?\u003c\/strong\u003e\u003cbr\u003eIt ensures stable signal performance under elevated thermal conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates into the 3300 XL monitoring architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect performance?\u003c\/strong\u003e\u003cbr\u003eWithin specification, 4.5 m length maintains stable signal transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid routing near high-temperature steam lines exceeding rated limits.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-power electrical cables to reduce EMI interference.\u003c\/p\u003e\n\u003cp\u003eEnsure correct connector engagement to maintain signal stability.\u003c\/p\u003e\n\u003cp\u003eUse appropriate cable supports to prevent mechanical stress in high-vibration areas.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius to protect triaxial shielding integrity.\u003c\/p\u003e\n\u003cp\u003eInspect insulation condition during scheduled maintenance in high-heat environments.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shielding for optimal noise suppression.\u003c\/p\u003e\n\u003cp\u003eAvoid direct contact with hot surfaces or radiant heat sources.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319105387,"sku":"330190-045-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330190-045-00-00-extension-cable-vv44ifx1gve_81f44a4c-8bd7-4af8-8fdb-50fa958ad864.jpg?v=1765440498"},{"product_id":"bently-nevada-330730-080-13-cn-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-080-13-CN 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330730-080-13-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 11 mm extension cable designed for vibration monitoring systems used in heavy industrial rotating machinery. It is widely applied in turbines, compressors, and large motor-driven equipment in power plants, oil refineries, and mining operations.\u003c\/p\u003e\n\u003cp\u003eThis cable ensures stable signal transmission between 11 mm proximity probes and monitoring modules under high vibration and electrically noisy conditions. The armored FluidLoc construction improves mechanical protection and maintains signal integrity in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe 8.0 meter length supports flexible installation layouts in distributed monitoring architectures while maintaining consistent electrical performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330730\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable with connector protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach configuration element defines mechanical protection level, cable length, and compliance classification within the 3300 XL 11 mm system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330730-080-13-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e11 mm extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eConnector protectors included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL 11 mm series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 11 mm cable series is engineered for enhanced signal stability in large rotating machinery applications where longer cable runs and higher electromagnetic interference levels are present.\u003c\/p\u003e\n\u003cp\u003eArmored FluidLoc construction provides mechanical durability while maintaining low-noise electrical performance, reducing the risk of signal distortion caused by vibration or cable movement.\u003c\/p\u003e\n\u003cp\u003eConnector protectors improve long-term reliability by preventing contamination and mechanical wear at interface points.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and large industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored FluidLoc design?\u003c\/strong\u003e\u003cbr\u003eIt increases mechanical durability and improves signal reliability in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all 11 mm probes?\u003c\/strong\u003e\u003cbr\u003eIt is designed for Bently Nevada 3300 XL 11 mm proximity systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy are connector protectors important?\u003c\/strong\u003e\u003cbr\u003eThey reduce contamination and mechanical damage at connection interfaces.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid tight bending near connector ends to preserve signal stability.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-voltage cables and VFD systems to reduce interference.\u003c\/p\u003e\n\u003cp\u003eEnsure connector locking is fully engaged during installation.\u003c\/p\u003e\n\u003cp\u003eSecure cable routing to avoid vibration-induced mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse proper strain relief at both ends to avoid load transfer to connectors.\u003c\/p\u003e\n\u003cp\u003eInspect armor integrity during scheduled maintenance cycles.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius for armored cable sections.\u003c\/p\u003e\n\u003cp\u003eEnsure grounding continuity for shielding effectiveness in noisy environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319138155,"sku":"330730-080-13-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330730-080-13-cn-kzhtnrvtql2_2c22313d-9614-48ef-a61d-d34f6f313b5d.jpg?v=1765521131"},{"product_id":"bently-nevada-330190-080-00-cn-3300-xl-extended-temperature-range-etr-extension-cable","title":"Bently Nevada 330190-080-00-CN | 3300 XL Extended Temperature Range (ETR) Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330190-080-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL Extended Temperature Range (ETR) extension cable designed for vibration monitoring systems operating in elevated and thermally unstable industrial environments. It is applied in turbines, compressors, petrochemical units, and power generation systems where signal stability must be maintained under continuous thermal stress.\u003c\/p\u003e\n\u003cp\u003eThis cable supports reliable signal transmission between proximity probes and monitoring modules while maintaining electrical integrity across extended temperature conditions. It reduces measurement drift and protects machine protection systems from signal degradation in harsh operating zones.\u003c\/p\u003e\n\u003cp\u003eThe 8.0 meter configuration provides flexible installation for distributed monitoring layouts in large industrial machinery assemblies.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330190\u003c\/td\u003e\n\u003ctd\u003e3300 XL extended temperature range cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines mechanical configuration, electrical design standard, and compliance classification within the ETR extension cable family.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-080-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended temperature range extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, FEP insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Capability\u003c\/td\u003e\n\u003ctd\u003eExtended temperature design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ETR cable series is designed for environments where standard extension cables cannot maintain stable electrical characteristics under elevated temperatures.\u003c\/p\u003e\n\u003cp\u003eFluoroethylene propylene (FEP) insulation improves thermal resistance and chemical stability, making the cable suitable for oil, gas, and high-temperature industrial environments.\u003c\/p\u003e\n\u003cp\u003eTriaxial construction ensures low-noise signal transmission and stable impedance characteristics across long cable runs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and high-temperature industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes ETR cables different?\u003c\/strong\u003e\u003cbr\u003eThey maintain electrical stability under extended temperature conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is fully compatible with 3300 XL proximity measurement architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is triaxial construction important?\u003c\/strong\u003e\u003cbr\u003eIt reduces noise and improves signal stability in electrically harsh environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid routing near high-temperature steam lines or heat sources exceeding rated limits.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shielding to maintain signal integrity in noisy electrical environments.\u003c\/p\u003e\n\u003cp\u003eMaintain proper bend radius to avoid degradation of triaxial shielding structure.\u003c\/p\u003e\n\u003cp\u003eVerify connector seating before commissioning to ensure stable measurement output.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse thermal spacing in cable routing to avoid continuous exposure to radiant heat sources.\u003c\/p\u003e\n\u003cp\u003eEnsure proper strain relief at cabinet entry points to prevent mechanical stress transfer.\u003c\/p\u003e\n\u003cp\u003eInspect insulation condition periodically in high-temperature applications.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high-power electrical cables to minimize EMI interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319203691,"sku":"330190-080-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330190-080-00-cn-smlnidfadci_9cfde8bb-9bc1-4ff1-8ff6-c9d3ef82773c.jpg?v=1765521134"},{"product_id":"bently-nevada-330130-040-11-00-3300-xl-extension-cable","title":"Bently Nevada 330130-040-11-00 3300 XL Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330130-040-11-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL extension cable designed for reliable signal transmission in proximity measurement systems used for vibration and shaft position monitoring. It is commonly deployed in turbines, compressors, generators, and industrial rotating machinery where stable signal integrity directly impacts machine protection performance.\u003c\/p\u003e\n\u003cp\u003eThis cable supports armored FluidLoc construction, which improves resistance to mechanical damage, oil exposure, and harsh industrial handling conditions. It ensures stable electrical continuity between proximity probes and monitoring modules in high-vibration environments.\u003c\/p\u003e\n\u003cp\u003eThe 4.0 meter length configuration provides flexible installation in control cabinets and field-mounted monitoring systems while maintaining signal stability across extended routing paths.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConstruction \u0026amp; Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e040\u003c\/td\u003e\n\u003ctd\u003e4.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe configuration defines cable length, mechanical protection level, and compliance scope within the 3300 XL system architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-040-11-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eMechanical abrasion resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is engineered to maintain low-noise signal transmission between proximity probes and monitoring systems in high-vibration industrial environments.\u003c\/p\u003e\n\u003cp\u003eArmored FluidLoc construction provides enhanced mechanical durability, reducing risk of cable damage during installation and long-term operation in harsh machinery areas.\u003c\/p\u003e\n\u003cp\u003eThe shielding design ensures signal stability in electrically noisy environments such as turbine halls and compressor stations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in vibration monitoring systems for turbines, compressors, and industrial rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored FluidLoc design?\u003c\/strong\u003e\u003cbr\u003eIt improves mechanical protection and reduces signal disruption in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for Bently Nevada 3300 XL proximity measurement systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect signal quality?\u003c\/strong\u003e\u003cbr\u003eWithin system specifications, 4.0 m length maintains stable signal performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid sharp bending during installation to prevent damage to internal conductors and shielding.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-voltage and VFD cables to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eEnsure connectors are fully engaged and locked to prevent intermittent signal loss.\u003c\/p\u003e\n\u003cp\u003eSecure cable routing to avoid mechanical stress from vibration or movement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius for armored construction to prevent long-term fatigue.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief at connection points to protect connector integrity.\u003c\/p\u003e\n\u003cp\u003eInspect cable shielding continuity during commissioning for optimal signal performance.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of system shielding to minimize electrical noise interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319236459,"sku":"330130-040-11-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-040-11-00-extension-cable-qn2ay5mvagf_f310ea0b-ffcd-478a-8ed5-6392231e7e8a.jpg?v=1765440915"},{"product_id":"bently-nevada-330130-075-01-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-01-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330130-075-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL standard extension cable designed for vibration monitoring signal transmission in turbines, compressors, generators, and refinery rotating machinery. It connects proximity probes to Proximitor modules within the Bently Nevada 3300 XL eddy-current measurement system.\u003c\/p\u003e\n\u003cp\u003eThis 7.5 m armored configuration is used in environments with high mechanical risk, such as heavy industrial skids, offshore platforms, and plant areas with potential cable abrasion or impact exposure. The armored structure increases mechanical protection and improves long-term reliability under vibration and harsh installation conditions.\u003c\/p\u003e\n\u003cp\u003eThe CN approval option supports region-specific compliance requirements while maintaining full compatibility with global 3300 XL monitoring architectures used in power generation and process industries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e075\u003c\/td\u003e\n\u003ctd\u003e7.5 m cable length (24.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eArmored cable construction option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approval configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach segment defines cable length, mechanical protection level, and regulatory compliance classification within the 3300 XL system framework.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-075-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e7.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL armored extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Design\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003ePassive component, no external power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Protection\u003c\/td\u003e\n\u003ctd\u003eArmored cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eUse armored cable in areas with high risk of mechanical impact, abrasion, or cable crushing. Typical applications include compressor skids, turbine enclosures, and offshore installations.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable routing even with armored protection. Armoring does not eliminate EMI sensitivity, so separation from high-voltage lines is still required.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bending at entry and exit points of armored sections. Excess stress can reduce connector alignment stability over time.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Troubleshooting Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main advantage of armored extension cable?\u003c\/strong\u003e\u003cbr\u003eIt provides mechanical protection against impact, abrasion, and crushing in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan armored cable improve signal quality?\u003c\/strong\u003e\u003cbr\u003eNo. It improves mechanical durability only. Signal quality depends on shielding and routing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs CN version different electrically?\u003c\/strong\u003e\u003cbr\u003eNo. CN refers only to compliance approval, not electrical characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes signal instability in armored cable systems?\u003c\/strong\u003e\u003cbr\u003eIncorrect grounding, poor connector engagement, or EMI from nearby power cables.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius even with armored protection to avoid internal conductor stress and shielding degradation.\u003c\/p\u003e\n\u003cp\u003eRoute cable away from VFD output cables and high-current bus systems to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eEnsure proper connector seating during installation. Armored cable rigidity can increase stress at termination points if misaligned.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321399147,"sku":"330130-075-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-075-01-cn-mzzno3tgoem_e92964c4-a83e-42f0-a0d7-27ac6706a298.jpg?v=1765521157"},{"product_id":"bently-nevada-330130-070-00-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-070-00-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eOperational Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-070-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL extension cable used in vibration monitoring systems for turbines, compressors, generators, and other critical rotating equipment. It connects proximity probes to Proximitor modules and ensures stable signal transmission within the eddy-current measurement loop.\u003c\/p\u003e\n\u003cp\u003eThis 7.0 m cable supports medium-range installation layouts in industrial skids and turbine housings. It maintains impedance stability under vibration, thermal cycling, and electrical noise conditions. In condition monitoring systems, this cable plays a direct role in preserving signal accuracy and preventing false vibration alarms that can trigger unnecessary shutdowns.\u003c\/p\u003e\n\u003cp\u003eThe CN configuration provides region-specific compliance support while maintaining full compatibility with standard 3300 XL system architecture used globally in power generation and process industries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCable Structure Interpretation\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e070\u003c\/td\u003e\n\u003ctd\u003e7.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eRegional compliance approval option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe structure defines physical length, construction type, and regulatory classification within the Bently Nevada 3300 XL monitoring ecosystem.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eElectrical \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-070-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e7.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL standard extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Design\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eProcurement Guide (Buying Strategy Notes)\u003c\/h3\u003e\n\u003cp\u003eExtension cables in Bently Nevada systems are not interchangeable without system consideration. Buyers must confirm three key parameters before purchase:\u003c\/p\u003e\n\u003cp\u003eFirst, verify total loop length including probe, extension cable, and Proximitor input requirements. Incorrect length selection affects gap voltage scaling and vibration accuracy.\u003c\/p\u003e\n\u003cp\u003eSecond, confirm connector type compatibility. 3300 XL systems require matched coaxial connector standards to ensure stable signal integrity under vibration conditions.\u003c\/p\u003e\n\u003cp\u003eThird, evaluate environmental exposure. In turbine and compressor installations, cable routing must account for heat, oil mist, and continuous vibration stress.\u003c\/p\u003e\n\u003cp\u003eFor long-term procurement planning, engineers typically standardize cable lengths across multiple machines to simplify spare parts inventory and reduce maintenance complexity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePurchase Notes (Compliance \u0026amp; Risk Control)\u003c\/h3\u003e\n\u003cp\u003eThis product is designed for industrial monitoring systems only and must be installed by qualified instrumentation personnel.\u003c\/p\u003e\n\u003cp\u003eIncorrect installation or mismatch with non-3300 XL components may result in signal distortion or monitoring failure.\u003c\/p\u003e\n\u003cp\u003eCN approval versions are intended for region-specific regulatory compliance. Buyers should confirm required certification scope before deployment in hazardous areas.\u003c\/p\u003e\n\u003cp\u003eAll cables should be stored in controlled environments before installation to avoid insulation aging or connector contamination.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain physical separation between signal cables and high-voltage power lines to reduce electromagnetic interference in VFD-driven systems.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bends during installation. Excess mechanical stress may degrade shielding performance and long-term impedance stability.\u003c\/p\u003e\n\u003cp\u003eUse single-point grounding at the monitoring system level. Multiple grounding points can introduce loop current and measurement drift.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Troubleshooting Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes unstable vibration readings in extension cable systems?\u003c\/strong\u003e\u003cbr\u003eImproper routing, damaged shielding, or loose connector engagement are the most common causes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan incorrect cable length affect system calibration?\u003c\/strong\u003e\u003cbr\u003eYes. Total loop length must match system design to ensure correct gap voltage output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs CN version different in electrical performance?\u003c\/strong\u003e\u003cbr\u003eNo. CN only defines compliance approval, not electrical characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the most common installation error?\u003c\/strong\u003e\u003cbr\u003eIncorrect cable routing near power conductors and improper connector locking.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure controlled routing from probe to Proximitor to avoid EMI coupling in turbine and compressor environments.\u003c\/p\u003e\n\u003cp\u003eVerify ClickLoc connector engagement during installation. Partial locking may cause intermittent signal loss under vibration.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius throughout cable path to preserve shielding integrity and impedance stability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321464683,"sku":"330130-070-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-070-00-cn-standard-extension-cable-on0jgnrrs1t_360967c8-6bde-432f-8b76-06a29971e9d1.jpg?v=1765448949"},{"product_id":"330190-080-00-00-bently-nevada-3300-xl-extended-temperature-range-etr-extension-cable","title":"330190-080-00-00 | Bently Nevada | 3300 XL Extended Temperature Range (ETR) Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330190-080-00-00\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a Bently Nevada 3300 XL Extended Temperature Range (ETR) extension cable engineered for vibration monitoring systems in turbines, compressors, and critical rotating machinery. It supports stable signal transmission between proximity probes and Proximitor sensors in high-temperature industrial environments such as power plants, oil refineries, and mining operations.\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL ETR cable maintains measurement integrity under thermal stress and continuous vibration exposure. It uses a 75 ohm triaxial structure with FEP insulation to improve dielectric stability and chemical resistance. This design reduces signal drift and helps condition monitoring systems maintain accurate shaft displacement and vibration data.\u003c\/p\u003e\n\u003cp\u003eOperators use this cable in environments where standard extension cables fail due to elevated temperature or chemical exposure. It directly supports machine protection strategies by reducing false alarms and preventing unnecessary shutdown events in critical production assets.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration Logic\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330190\u003c\/td\u003e\n\u003ctd\u003e3300 XL Extended Temperature Range extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 m cable length (26.2 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe ETR design focuses on thermal resilience rather than certification variants. The structure uses triaxial geometry with FEP insulation to maintain electrical stability in elevated temperature zones.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-080-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.289 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, FEP insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard coiled industrial cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component, no power required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe extension in rotating machinery systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL ETR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Impedance\u003c\/td\u003e\n\u003ctd\u003e75 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs 330190-080-00-00 compatible with standard 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes. It works with Bently Nevada 3300 XL proximity transducer systems when used with compatible probes and Proximitor sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main advantage of ETR cable over standard extension cable?\u003c\/strong\u003e\u003cbr\u003eETR cable provides higher temperature tolerance and improved insulation stability in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable operate in turbine casing environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly installed in turbine housings where heat and vibration exceed standard cable limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect calibration?\u003c\/strong\u003e\u003cbr\u003eYes. System loop calibration must match total probe, extension, and Proximitor configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain proper separation between signal cables and power wiring to reduce electromagnetic interference in high-noise environments such as VFD-driven compressor systems.\u003c\/p\u003e\n\u003cp\u003eDo not exceed minimum bend radius during installation. Mechanical stress on triaxial shielding can degrade signal stability over time.\u003c\/p\u003e\n\u003cp\u003eIn high-temperature zones, route cables away from direct radiant heat sources. Use approved clamps to prevent vibration fatigue at connector points.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321562987,"sku":"330190-080-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330190-080-00-00-t5xmwdt0s2f_f4696e94-58d3-48ed-8cbe-71176a8767dd.jpg?v=1765521163"},{"product_id":"bently-nevada-330130-075-10-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-10-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-075-10-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL standard extension cable designed for high-reliability vibration monitoring systems in refineries, gas turbines, steam turbines, compressors, and power generation assets. This extension cable connects 3300 XL proximity probes to Proximitor sensors and maintains signal integrity in continuous condition monitoring applications.\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL series supports critical rotating equipment protection where stable vibration data directly reduces unplanned shutdown risk. Bently Nevada uses high-performance coaxial construction and industrial-grade shielding to improve resistance against electrical noise, oil contamination, and mechanical stress.\u003c\/p\u003e\n\u003cp\u003eThe 7.5 m cable configuration fits medium-distance field installations inside turbine enclosures, compressor skids, and hazardous process environments. The FluidLoc cable option improves sealing performance in oil-exposed applications and helps prevent fluid migration through the cable assembly. The -CN suffix identifies the China hazardous area approval package, including applicable NEPSI and related regional certifications for explosive gas environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e075\u003c\/td\u003e\n\u003ctd\u003e7.5 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eFluidLoc cable option with enhanced fluid resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eChina hazardous area approval package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-075-10-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e7.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFluidLoc coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eStandard Bently Nevada compatible connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive device, no external power required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade shielded coaxial construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe extension connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Approval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area approval package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL proximity transducer systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Details\u003c\/h3\u003e\n\u003cp\u003eThe 330130 extension cable operates within Bently Nevada proximity transducer systems used for shaft vibration and position monitoring. Engineers commonly install this cable in centrifugal compressors, steam turbines, hydro turbines, and critical motor systems.\u003c\/p\u003e\n\u003cp\u003eFluidLoc technology improves reliability in oil-rich turbine compartments and lubrication-intensive machinery areas. The cable construction minimizes moisture ingress and maintains stable signal transmission during long-term operation under vibration and thermal cycling conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 330130-075-10-CN compatible with all 3300 XL probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable supports standard Bently Nevada 3300 XL 8 mm proximity transducer systems with compatible probe and Proximitor configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the FluidLoc option provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc cable structure reduces fluid migration through the cable jacket. This feature improves reliability in turbine oil and compressor lubrication environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable operate in hazardous areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The -CN suffix includes China hazardous area approvals for applicable explosive gas installations when used within approved system configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this extension cable require calibration after replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEngineers should verify the complete transducer system length and perform gap voltage validation after installation. System calibration depends on the total matched probe system configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eUse dedicated cable routing away from high-voltage motor cables and VFD output wiring. Proper separation reduces electromagnetic interference during vibration signal transmission.\u003c\/p\u003e\n\u003cp\u003eDo not exceed the specified bending radius during installation. Excessive cable stress may affect shielding performance and long-term signal stability.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing surfaces before installation in oil-contaminated environments. Clean mating surfaces improve environmental protection and connector reliability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321595755,"sku":"330130-075-10-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-075-10-cn-x4tc333h1cw_af9c6aa5-972e-4176-816c-11238e244953.jpg?v=1765521164"},{"product_id":"bently-nevada-330130-180-00-cn-3300-xl-extension-cable-assembly","title":"Bently Nevada 330130-180-00-CN 3300 XL Extension Cable Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-180-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL extension cable designed for reliable signal transmission in proximity probe vibration monitoring systems. This cable is part of the 3300 XL transducer chain used in turbines, compressors, pumps, and critical rotating machinery where uninterrupted vibration data ensures safe plant operation. It supports stable electrical continuity between probe and proximitor module in high-noise industrial environments.\u003c\/p\u003e\n\u003cp\u003eThis model has been replaced by 330130-080-00-CN in updated configurations, but it remains widely used in installed base systems across oil refineries, power generation plants, and offshore platforms. The CN suffix indicates China-specific hazardous area approval coverage, including NEPSI-related compliance for explosive environments. Its robust construction ensures consistent impedance behavior and minimizes signal degradation over extended routing distances.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330130 = 3300 XL extension cable platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e180 = cable length option (system-specific legacy configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00 = standard cable with no additional connector protection features\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN = China country-specific hazardous area approvals (NEPSI compliance support)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable is engineered with controlled impedance design to maintain accurate proximity probe signal transmission. It integrates directly into Bently Nevada 3300 XL systems without additional signal conditioning requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-180-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Option\u003c\/td\u003e\n\u003ctd\u003e180 (legacy system configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Protection\u003c\/td\u003e\n\u003ctd\u003eStandard (00 option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Weight\u003c\/td\u003e\n\u003ctd\u003e0.034 kg\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Shipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Function\u003c\/td\u003e\n\u003ctd\u003eSignal transmission for proximity system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL probe and proximitor systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade shielded construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs 330130-180-00-CN still supported in modern systems?\u003c\/strong\u003e\u003cbr\u003eIt is supported in installed base systems but replaced by 330130-080-00-CN in updated configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be mixed with other 3300 XL cable lengths?\u003c\/strong\u003e\u003cbr\u003eYes, but total system calibration must remain within Bently Nevada recommended limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does CN approval indicate for this cable?\u003c\/strong\u003e\u003cbr\u003eCN indicates China-specific hazardous area certification compliance including NEPSI-related approvals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes signal noise in extension cable systems?\u003c\/strong\u003e\u003cbr\u003eImproper grounding, cable routing near VFDs, or damaged shielding typically introduces signal noise.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eMaintain continuous shielding integrity across the full cable run to avoid electromagnetic interference. Broken shielding increases vibration signal distortion.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bending radius during installation. Excess mechanical stress can alter impedance characteristics and degrade measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eRoute extension cables separately from power cables and variable frequency drive lines. Proper separation improves long-term signal stability in industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321956203,"sku":"330130-180-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-180-00-cn-xobbvbfka1q_27b330d4-a1d9-4704-b95a-11f8b24b3c74.jpg?v=1765521178"},{"product_id":"bently-nevada-330930-065-04-cn-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-04-CN 3300 NSv Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-065-04-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 NSv extension cable designed for signal transmission within compact proximity transducer systems used in turbines, compressors, pumps, and other rotating machinery. This extension cable supports industrial applications in refineries, power plants, and petrochemical facilities where reliable vibration and shaft position monitoring is essential. The stainless steel armored construction with FEP jacket improves resistance against abrasion, oil exposure, moisture, and chemical contamination. Connector protectors enhance long term connection stability under vibration conditions. Engineers use this cable to maintain signal integrity between NSv probes and proximitor sensors, reducing measurement errors and preventing unexpected machinery downtime in hazardous operating environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code defines cable configuration and hazardous area compliance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e065\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Cable length 6.5 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Stainless steel armored cable with FEP jacket and connector protectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= China-specific hazardous area approvals including NEPSI, CCC, and ATEX IECEx compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration ensures compatibility with harsh industrial installations and hazardous area requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330930-065-04-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.5 metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStainless steel armored FEP cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated connector protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity transducer systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary application of this extension cable?\u003c\/strong\u003e\u003cbr\u003eIt connects 3300 NSv probes and proximitor sensors in machinery monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does this model use an FEP jacket?\u003c\/strong\u003e\u003cbr\u003eThe FEP jacket provides enhanced resistance to chemicals, oil, and high temperature environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the CN suffix indicate?\u003c\/strong\u003e\u003cbr\u003eIt confirms compliance with China-specific hazardous area certifications including NEPSI and CCC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable operate in high vibration environments?\u003c\/strong\u003e\u003cbr\u003eYes. The stainless steel armor improves mechanical protection and vibration resistance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from motor power wiring to minimize electromagnetic interference.\u003cbr\u003eInspect connector protectors regularly to prevent contamination or moisture ingress.\u003cbr\u003eUse secure mounting supports to reduce cable movement and prevent armor fatigue in vibrating installations.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322087275,"sku":"330930-065-04-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-065-04-cn-jguk1yd4xlq_b81f867b-ecb4-4b73-9360-4f8aa648ca8e.jpg?v=1765521186"},{"product_id":"bently-nevada-330130-075-12-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-12-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-075-12-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL standard extension cable designed for use within 3300 XL 8 mm proximity transducer systems. This cable provides stable signal transmission between proximity probes and proximitor sensors in rotating machinery monitoring applications. Industries such as oil refining, gas compression, and power generation rely on this extension cable for continuous vibration and shaft position monitoring. The FluidLoc cable construction improves resistance to oil ingress and harsh environmental exposure, while the connector protector enhances long term connector reliability. Its CN hazardous area approval supports safe deployment in explosive gas and dust environments, helping operators maintain reliable machine protection and reduce unplanned outages.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model structure defines cable length, mechanical protection, and certification:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e075\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Cable length 7.5 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= FluidLoc cable with connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= ATEX IECEx and Chinese NEPSI hazardous area approval marking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration ensures compatibility with hazardous area installations and demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-075-12-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e34 g per metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.5 metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFluidLoc industrial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eATEX IECEx and NEPSI certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the FluidLoc cable design?\u003c\/strong\u003e\u003cbr\u003eFluidLoc construction helps prevent oil migration and improves long term cable durability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with 3300 XL proximity systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is specifically designed for Bently Nevada 3300 XL transducer systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the CN approval indicate?\u003c\/strong\u003e\u003cbr\u003eIt confirms compliance with Chinese NEPSI and international ATEX IECEx hazardous area standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable operate in high vibration environments?\u003c\/strong\u003e\u003cbr\u003eYes. The reinforced industrial design supports reliable operation under continuous vibration exposure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the extension cable separately from high voltage conductors to reduce electromagnetic interference.\u003cbr\u003eInspect connector protectors during maintenance intervals to prevent moisture or contamination ingress.\u003cbr\u003eUse secure mounting clamps to minimize cable movement and mechanical fatigue in vibrating equipment areas.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322185579,"sku":"330130-075-12-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-075-12-cn-zervmrm23oa_e970c39d-6b24-4dd4-b7dd-1976f9734346.jpg?v=1765521189"},{"product_id":"bently-nevada-330130-075-12-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-12-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-075-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL standard extension cable from Bently Nevada is designed for reliable signal transmission in proximity probe monitoring systems used in turbines, compressors, pumps, and other critical rotating machinery. It is widely applied in power generation, oil and gas processing, petrochemical plants, and heavy industrial facilities where stable vibration monitoring is essential for preventing equipment failure and unplanned downtime.\u003c\/p\u003e\n\u003cp\u003eThis extension cable is part of the 3300 XL transducer system and ensures accurate signal integrity between proximity probes and monitoring modules. The 7.5 meter cable length provides flexible installation routing in large machinery systems and industrial enclosures. The FluidLoc design with connector protector improves resistance against moisture ingress and contamination in harsh environments. The CSA, ATEX, and IECEx approval package supports hazardous area installations requiring international compliance standards. The cable maintains consistent electrical performance under continuous industrial vibration and thermal variation conditions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e075\u003c\/td\u003e\n\u003ctd\u003eCable length: 7.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eFluidLoc cable with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-075-12-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e7.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Rating\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e34 g\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL proximity monitoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade triaxial shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the FluidLoc design?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc design helps prevent moisture ingress and contamination at connector points in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with all 3300 XL probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is designed for use within the Bently Nevada 3300 XL proximity measurement system when properly matched with probes and Proximitor sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in hazardous areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports CSA, ATEX, and IECEx approvals for use in explosive gas and dust environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect system performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Proper system matching is required to maintain signal accuracy and calibration consistency in vibration monitoring systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute extension cables separately from power cables and VFD outputs to reduce electromagnetic interference in monitoring systems.\u003c\/p\u003e\n\u003cp\u003eEnsure connector protector is properly engaged to maintain sealing integrity in high humidity or contaminated environments.\u003c\/p\u003e\n\u003cp\u003eUse proper cable support along trays to prevent mechanical stress and vibration fatigue at connector interfaces.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322480491,"sku":"330130-075-12-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-075-12-05-fxkf3o2r1nz_d311a868-deca-49a3-93aa-9d9d1b0d655d.jpg?v=1765521199"},{"product_id":"bently-nevada-330130-085-01-05-3300-xl-extension-cable","title":"Bently Nevada 330130-085-01-05 3300 XL Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-085-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL extension cable from Bently Nevada supports high-accuracy vibration and proximity monitoring systems used in turbines, compressors, pumps, and critical rotating machinery. This armored extension cable operates as part of the 3300 XL transducer system and provides stable signal transmission between the proximity probe and Proximitor sensor. Power generation plants, refinery facilities, LNG terminals, and petrochemical sites commonly install this cable in high-vibration industrial environments where signal integrity directly affects machine protection reliability.\u003c\/p\u003e\n\u003cp\u003eThe armored construction improves resistance against mechanical damage, oil exposure, and cable tray abrasion. The multiple approval configuration supports installation in hazardous industrial areas that require international certification compliance. The 8.5 m cable length allows flexible routing inside turbine enclosures, compressor skids, and machinery cabinets while maintaining proper electrical characteristics for the 3300 XL monitoring system.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL Extension Cable Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e085\u003c\/td\u003e\n\u003ctd\u003e8.5 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eArmored cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-085-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eArmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e34 g\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eClickLoc coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003eFluoroethylene propylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eFactory shielded coaxial construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this extension cable operate with older 3300 monitoring systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable supports 3300 XL proximity systems directly. Compatibility with legacy 3300 systems depends on probe and Proximitor configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the armored version improve reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe armored structure protects the cable from crushing, abrasion, vibration stress, and accidental mechanical impact in industrial installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the cable length affect proximity probe calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Bently Nevada proximity systems require matched electrical lengths between the probe, extension cable, and Proximitor sensor for accurate measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 05 approval option suitable for hazardous locations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The multiple approval option supports installations requiring international hazardous area certifications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the extension cable separately from high-voltage motor cables to reduce electromagnetic interference. Maintain proper grounding practices at the monitoring cabinet to improve signal stability.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive bending near connector assemblies during installation. Tight bend radius conditions may affect long-term shielding integrity and connector performance.\u003c\/p\u003e\n\u003cp\u003eUse proper cable clamps inside turbine and compressor skids to minimize vibration transfer into the connector interface. High-vibration environments require stable mechanical support for reliable monitoring operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322840939,"sku":"330130-085-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-085-01-05-3300-xl-standard-extension-cable-gd44ssimpmp_c73fb525-5a79-4902-b8ed-5e98f0f9286c.jpg?v=1765446982"},{"product_id":"bently-nevada-330130-080-03-cn-3300-xl-standard-extension-cable-1","title":"Bently Nevada 330130-080-03-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-080-03-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL standard extension cable designed for reliable signal transmission between proximity probes and proximitor sensors in rotating equipment monitoring systems. This cable operates in demanding industries such as oil and gas, power generation, and petrochemical processing. It ensures consistent signal integrity over extended distances, which is critical for accurate vibration and displacement measurement. The armored construction with connector protectors enhances durability against mechanical stress, moisture, and industrial contaminants. Engineers use this cable to maintain stable system performance and reduce diagnostic errors. The CN approval ensures compliance with China hazardous area standards, supporting safe operation in explosive gas and dust environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model configuration defines cable structure and compliance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e080\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Cable length 8.0 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Armored cable with connector protectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= China-specific hazardous area approvals including NEPSI, CCC, and ATEX IECEx\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis coding structure ensures correct installation length and suitability for hazardous environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-080-03-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.0 metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eArmored industrial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eStandard 3300 XL connectors with protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with 3300 XL proximity systems?\u003c\/strong\u003e\u003cbr\u003eYes. It supports full compatibility with 3300 XL probes and proximitor sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between option 03 and other cable types?\u003c\/strong\u003e\u003cbr\u003eOption 03 provides armored protection with connector protectors for enhanced mechanical durability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the CN suffix indicate?\u003c\/strong\u003e\u003cbr\u003eIt confirms compliance with China-specific hazardous area certification standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable handle harsh industrial environments?\u003c\/strong\u003e\u003cbr\u003eYes. The armored design resists vibration, oil exposure, and mechanical damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from high voltage cables to minimize electromagnetic interference.\u003cbr\u003eUse proper cable clamps to prevent movement and reduce fatigue under vibration.\u003cbr\u003eCheck connector sealing during installation to maintain protection against moisture ingress.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323496299,"sku":"330130-080-03-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-080-03-cn-3300-xl-standard-extension-cable-2uhlynzxar5_26521c9d-5472-41b4-90f9-20cdc6ddbdaa.jpg?v=1765444111"},{"product_id":"330130-080-13-cn-bently-nevada-3300-xl-standard-extension-cable","title":"330130-080-13-CN | Bently Nevada | 3300 XL Standard Extension Cable","description":"\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-080-13-CN \u003c\/strong\u003estandard extension cable is a high-integrity signal transmission link engineered for the 3300 XL 8 mm proximity transducer system. Deployed extensively in high-vibration, chemically aggressive environments like steam turbine generator sets, large-scale refining compressors, and heavy mining excavators, this armored cable preserves the precise RF signal between the sensor probe and the Proximitor. Featuring integrated fluid-blocking technology, it prevents process liquids and high-pressure steam from leaking through the cable core into delicate junction boxes. Integrating this heavy-duty, armored extension line ensures steady, noise-free machine diagnostics, shielding your critical turbomachinery loops against false trips and minimizing unplanned downtime.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configurations\u003c\/h3\u003e\n\u003cp\u003eThe precise engineering suffix structure of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-080-13-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eextension cable designates its length, mechanical armor, and global regulatory compliance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330130\u003c\/strong\u003e: Base model designator for the high-performance 3300 XL Standard Extension Cable series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e080\u003c\/strong\u003e: Cable Length Option specifying exactly 8.0 metres (26.2 feet) of calibrated electrical length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e13\u003c\/strong\u003e: Connector Protector and Cable Option equipping a ruggedized stainless steel outer armor, FluidLoc gas\/liquid-tight internal sealing, and a pre-installed protective sleeve for the coaxial junction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: China-specific hazardous area approvals, covering NEPSI and CCC requirements alongside ATEX\/IECEx certifications for intrinsically safe or flameproof operations in volatile gas and dust environments. This globally procured version ensures compliance for equipment intended for, or compatible with, Chinese industrial markets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Field\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Parameter Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-080-13-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm coaxial transmission path\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter Construction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless steel flexible protective armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Sealing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc moisture-proof and gas-tight core barrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJunction Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMolded ClickLoc connector protector sleeve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to 177 deg C (-60 deg F to 351 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Cable Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGross Shipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg (including protective industrial packing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Field FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the exact 8.0 metres length of this cable critical for system calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Eddy current proximity sensors rely on a tuned resonant circuit calibrated to a specific total electrical length (typically 9.0 metres). Pairing an 8.0 metres extension cable with a 1.0 metre probe matches this exact calibration profile. Mismatching these lengths will cause severe linearity errors in your gap and vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary purpose of the FluidLoc seal in the \"13\" option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The FluidLoc feature is an internal barrier inside the coaxial cable that blocks oil, water, or process gases from flowing inside the cable jacket. This is vital when the probe is mounted inside a pressurized oil-mist environment, preventing process fluids from migrating into the external field wiring cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this armored extension cable be installed in cable trays without conduit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The flexible stainless steel armor provides robust mechanical protection against crushing, abrasive wear, and cutting. It allows for direct routing in open cable trays, reducing overall installation costs while maintaining physical signal path integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eMechanical Installation \u0026amp; Grounding Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Length Match Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrior to mounting, verify that the total combined length of your proximity probe and this extension cable matches the calibration rating of your Proximitor sensor (e.g., a 1.0 m probe plus this 8.0 m cable equals a 9.0 m calibrated system). Using a 5.0 m Proximitor with this combination will cause immediate calibration and measurement faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintaining Minimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the stainless steel armor offers superior physical defense, do not bend the cable tighter than a minimum radius of 25.4 mm (1.0 inch). Kinking or over-bending the armor can distort the internal coaxial geometry, altering the system's impedance and degrading the vibration signal accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connection Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the pre-installed connector protector sleeve at the probe-to-extension cable junction. Ensure the ClickLoc connectors are clean, completely dry, and fully clicked into place before sliding the protector over the connection. Never allow the unshielded connector metal to touch the machine casing, as this creates ground loops that introduce massive electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323529067,"sku":"330130-080-13-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-080-13-cn-xwc4nvk2rdu_a34b171a-5a4b-4e20-a224-444f34bc7a77.jpg?v=1765521234"},{"product_id":"330930-065-05-cn-bently-nevada-3300-xl-nsv-proximity-extension-cable","title":"330930-065-05-CN Bently Nevada 3300 XL NSv Proximity Extension Cable","description":"\u003ch3 class=\"\"\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN \u003c\/strong\u003e\u003cspan class=\"\"\u003eis a high-performance extension cable designed specifically for the Bently Nevada 3300 XL NSv (Narrow Side view) Proximity Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specialized cable serves as the critical signal link between the proximity probe and the Proximitor Sensor,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaintaining impedance matching and signal integrity in demanding industrial environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for applications with tight spatial constraints where standard proximity probes cannot be used,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as small centrifugal compressors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epumps,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand motors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy ensuring precise transmission of eddy-current signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis cable facilitates accurate vibration and position monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edirectly contributing to the mechanical health and safety of high-speed rotating assets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis configured according to the following technical specifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e330930\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBase model for the 3300 XL NSv Extension Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e065 (Cable Length Option)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e6.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 meters (21.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 feet).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis length is specifically calibrated to match the system's electrical requirements for a total 7.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter or 9.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter system length.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e05 (Connector and Cable Option)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with heavy-duty stainless steel armor for superior mechanical protection; supplied without FEP jacket; includes factory-installed connector protectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCN (Agency Approval Option)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCertified for use in hazardous areas with ATEX\/IECEx and Chinese NEPSI markings,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring compliance with global and regional safety standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-065-05-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL NSv Proximity System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 g\/m (0.5 oz\/ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (AISI 302\/304)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area Marking\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX, IECEx, NEPSI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan this extension cable be used with a standard 3300 XL 8mm probe?\u003c\/strong\u003e\u003cspan class=\"\"\u003eNo.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis designed exclusively for the NSv system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUsing it with standard 5mm or 8mm systems will result in incorrect impedance matching and significant measurement errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the purpose of the stainless steel armor (Option 05)?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe armor provides high physical durability against crushing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eabrasion,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand rodent damage in industrial environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esince this version lacks the FEP jacket,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit is best suited for environments where chemical exposure is not the primary concern.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAre the connector protectors removable?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe connector protectors are designed to prevent the connectors from being damaged or contaminated during the \"pulling\" process through conduit.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThey should be used during installation and can be removed for final mating.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Integrity and Connector Maintenance\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe coaxial connectors on the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eare sensitive to moisture and oil.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAlways ensure connectors are clean and dry before mating.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWe recommend using a torque wrench specifically designed for proximity system connectors (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e45 N-m or 4 in-lb) to prevent over-tightening,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich can deform the center pin and lead to intermittent signal loss or \"spiking.\u003c\/span\u003e\u003cspan class=\"\"\u003e\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInstallation in Hazardous Areas\u003c\/strong\u003e\u003cspan class=\"\"\u003eAs a NEPSI and ATEX certified component,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis cable must be installed in accordance with the specific \"Conditions of Safe Use\" outlined in the certification documentation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the stainless steel armor is properly bonded to the machine ground at the bulkhead or junction box to prevent electrostatic buildup or potential differences in hazardous atmospheres.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCable Routing Limits\u003c\/strong\u003e\u003cspan class=\"\"\u003eWhile the stainless steel armor is robust,\u003c\/span\u003e\u003cspan\u003e observe the minimum bend radius of 25.\u003c\/span\u003e\u003cspan\u003e4 mm (1.\u003c\/span\u003e\u003cspan\u003e0 inch).\u003c\/span\u003e\u003cspan\u003e Kinking the cable will change its coaxial capacitance,\u003c\/span\u003e\u003cspan\u003e permanently altering the calibration of the entire proximity system and necessitating replacement of the cable to restore accuracy.\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324282731,"sku":"330930-065-05-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-065-05-cn-zw40ihoeo2y_07b1c5aa-d20e-4c0e-9876-b628f171d888.jpg?v=1765521259"},{"product_id":"bently-nevada-330130-045-13-00-3300-xl-extension-cable","title":"Bently Nevada 330130-045-13-00 3300 XL Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-045-13-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized extension cable for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity transducer system. This cable acts as the vital link between a 3300 XL proximity probe and a 3300 XL Proximitor® Sensor. Engineered for extreme industrial environments, this specific model features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFluidLoc® technology\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent moisture or oil from wicking through the cable and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estainless steel armor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect against mechanical crushing and abrasion.\u003c\/p\u003e\n\u003cp\u003eIn a standard vibration monitoring loop, the extension cable must be matched to the probe length to achieve a \"Total System Length\" (typically 5.0 or 9.0 meters). This ensures the electrical circuit is perfectly tuned for the eddy current measurement used to monitor shaft vibration and position.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe part number breakdown identifies the protective features and physical dimensions:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Length (045):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.5 metres (14.8 feet). When paired with a 0.5-meter probe, this creates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFluidLoc® Cable:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a patented internal design that blocks the \"wicking\" effect, ensuring that if one end of the cable is exposed to oil or pressurized fluids, the liquid cannot travel through the cable into the Proximitor housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArmored Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable is encased in flexible, interlocking stainless steel armor, providing superior crush resistance in areas with heavy foot traffic or sharp-edged machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protectors (13):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes clear, removable sleeves at the connection points to prevent the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClickLoc™\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectors from vibrating loose and to provide environmental sealing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Isolated Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard coaxial construction optimized for high-frequency signal transmission with minimal loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-045-13-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ω Coaxial (FluidLoc®)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 Metres\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Coaxial ClickLoc™\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in) for armored cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is FluidLoc® important for my installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn many turbines and gearboxes, the probe end is submerged in lubricating oil. Standard cables can act like a \"straw,\" allowing oil to seep through the internal gaps of the cable and eventually leak into the control cabinet.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFluidLoc®\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseals the internal cable structure to prevent this.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I cut this cable to a shorter length if it's too long?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNo.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3300 XL system is a tuned resonant circuit. The capacitance and inductance of the cable are calculated into the vibration reading. Cutting the cable will change the impedance, causing significant errors in the vibration measurement or making the system completely non-functional.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable require a specific Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, this cable must be used with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Proximitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfigured for a 5.0-meter system. Using it with a 9.0-meter Proximitor will result in incorrect scale factors and inaccurate data.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen joining the probe to the extension cable, ensure the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClickLoc™\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectors \"click\" into place. Slide the connector protector over the junction to ensure it remains locked despite machine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAvoid Sharp Bends:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough armored, the cable has a minimum bend radius. Forcing a sharp 90-degree bend can damage the internal coaxial dielectric, leading to \"noisy\" vibration signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit and Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the armor provides protection, the cable should still be supported by conduit or cable trays where possible. Avoid zip-tying the cable directly to high-voltage power lines to prevent electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3300 XL system typically expects a single-point ground at the Proximitor end. Ensure the armor is not inadvertently touching other grounded metal surfaces that could create a ground loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324643179,"sku":"330130-045-13-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-045-00-00-3300-xl-extension-cable-pqecofsscc3_49572228-e4ba-466b-8ebe-13aae2d74749.jpg?v=1765449301"},{"product_id":"bently-nevada-330930-045-01-cn-3300-nsv-armored-extension-cable","title":"Bently Nevada 330930-045-01-CN 3300 NSv Armored Extension Cable","description":"\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\nThe \u003cstrong\u003e330930-045-01-CN\u003c\/strong\u003e is a high-performance extension cable specifically engineered for the Bently Nevada 3300 NSv (Narrow Side view) proximity transducer system. \nThe NSv series is the industry standard for vibration and position monitoring in confined spaces or on small-diameter shafts where standard probes would suffer from side-viewing interference. \nThis cable provides the critical electrical link between the NSv probe and the Proximitor sensor, maintaining the precision impedance required for accurate eddy-current measurements. \nIdeal for aero-derivative gas turbines, centrifugal compressors, and small steam turbines, the \u003cstrong\u003e330930-045-01-CN\u003c\/strong\u003e features ruggedized armoring and chemical protection, ensuring maximum signal integrity and machine uptime in the most volatile industrial environments.\n\u003c\/p\u003e\n\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003e\nThe model \u003cstrong\u003e330930-045-01-CN\u003c\/strong\u003e is configured with specific mechanical and regional protection layers:\n\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330930\u003c\/strong\u003e: 3300 NSv Extension Cable series.\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e045\u003c\/strong\u003e: Cable Length Option – 4.5 meters (14.8 feet).\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: Connector and Cable Option – Equipped with stainless steel armor for mechanical protection, plus an external FEP (Fluoroethylenepropylene) jacket for superior chemical and moisture resistance.\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCN\u003c\/strong\u003e: Agency Approval Option – Country-specific approvals for the China market, ensuring compliance with local hazardous area and industrial safety regulations.\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930-045-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial with FEP insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel armor with FEP outer jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated miniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 inch) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eHow does the FEP jacket (Option 01) differ from the standard armored cable?\u003c\/strong\u003e\u003cbr\u003e\nWhile the stainless steel armor provides mechanical protection against crushing, the FEP jacket provides an additional layer of protection against environmental contaminants. \nIt prevents corrosive fluids, moisture, and oils from penetrating the armor braids and reaching the internal coaxial cable, significantly extending the cable's lifespan in harsh chemical environments.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eCan I use this 330930 cable with a 3300 XL 8 mm probe?\u003c\/strong\u003e\u003cbr\u003e\nNo. The 3300 NSv system is electrically distinct from the 3300 XL series. \nThe NSv cable is tuned to the specific inductance and capacitance requirements of the NSv probe and Proximitor. \nInterchanging them will lead to incorrect vibration readings and potential \"Not OK\" status at the monitoring rack.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eWhat is the importance of the total system length?\u003c\/strong\u003e\u003cbr\u003e\nBently Nevada proximity systems are calibrated as a complete loop (Probe + Extension Cable). \nA 4.5-meter cable is typically paired with a 0.5-meter probe to achieve a 5.0-meter system length. \nUsing a cable length that does not match the Proximitor sensor's calibration will cause a significant scale factor error.\n\u003c\/p\u003e\n\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e \nThe FEP jacket is highly resistant to most industrial solvents and fuels. \nEnsure the jacket is inspected for tears during installation. Any breach in the FEP layer can allow fluids to wick into the armor, potentially leading to signal degradation or ground faults.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e \nAlways use the ClickLoc connector system properly. \nWhen mating the probe lead to the extension cable, you should feel a distinct \"click\" indicating the gold-plated pins are fully seated. \nFailure to secure the connection can lead to intermittent signal loss, especially in high-vibration machinery.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocols:\u003c\/strong\u003e \nThe stainless steel armor should be electrically isolated from the machine casing and only grounded at the Proximitor sensor end. \nThis prevents ground loops, which are a common source of electrical noise in vibration signals.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMechanical Routing:\u003c\/strong\u003e \nAvoid routing the armored cable across sharp metal edges or in areas where it may be pinched by moving machinery components. \nDespite the armor, the internal coaxial dielectric can be crushed, which changes the cable's impedance and invalidates the sensor calibration.\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324970859,"sku":"330930-045-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-045-01-cn-pnahjolvj55_c106988e-90ec-4b4d-ac75-037d9e906d2e.jpg?v=1765521282"},{"product_id":"bently-nevada-330130-045-13-cn-3300-xl-extension-cable","title":"Bently Nevada 330130-045-13-CN 3300 XL Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-045-13-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a premium 3300 XL series extension cable engineered by Bently Nevada to maintain signal integrity in the most demanding industrial environments.\u003cspan\u003e \u003c\/span\u003eThis cable serves as the critical link between a 3300 XL proximity probe and a Proximitor sensor,\u003cspan\u003e \u003c\/span\u003eensuring the transmission of high-frequency eddy-current data without interference.\u003cspan\u003e \u003c\/span\u003eUtilizing FluidLoc technology and integrated armor,\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e330130-045-13-CN\u003cspan\u003e \u003c\/span\u003eis purpose-built for applications in steam turbines,\u003cspan\u003e \u003c\/span\u003ecooling towers,\u003cspan\u003e \u003c\/span\u003eand centrifugal pumps where exposure to moisture,\u003cspan\u003e \u003c\/span\u003eoil,\u003cspan\u003e \u003c\/span\u003eor physical abrasion is a constant risk.\u003cspan\u003e \u003c\/span\u003eBy providing a stable electrical path,\u003cspan\u003e \u003c\/span\u003eit ensures the accuracy of vibration and position monitoring,\u003cspan\u003e \u003c\/span\u003eallowing for precise predictive maintenance and the prevention of unplanned machinery outages.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e330130-045-13-CN\u003cspan\u003e \u003c\/span\u003esignifies a high-durability configuration designed for hazardous and wet locations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330130:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL Extension Cable series (Standard 8 mm and 5 mm compatibility).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e045:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCable Length Option - 4.5 meters (14.8 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e13:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnector Protector and Cable Option - Features FluidLoc cable construction to prevent moisture wicking and stainless steel armor for mechanical protection,\u003cspan\u003e \u003c\/span\u003eincluding pre-installed connector protectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAgency Approval Option - Country-specific approvals for the China market,\u003cspan\u003e \u003c\/span\u003ecertifying the cable for use in regulated hazardous industrial zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-045-13-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial with FluidLoc technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Protection\u003c\/td\u003e\n\u003ctd\u003eStainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eGold-plated miniature coaxial with ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e4.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg (approx. cable only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes the FluidLoc cable (Option 13) different from standard armored cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFluidLoc technology is specifically designed to prevent \"wicking.\" In standard cables,\u003cspan\u003e \u003c\/span\u003eif the jacket is cut,\u003cspan\u003e \u003c\/span\u003efluids like oil or water can travel through the interior of the cable and reach the Proximitor sensor or probe.\u003cspan\u003e \u003c\/span\u003eFluidLoc prevents this internal migration,\u003cspan\u003e \u003c\/span\u003eprotecting the sensitive electronic junctions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this extension cable compatible with 5 mm 3300 XL probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes,\u003cspan\u003e \u003c\/span\u003ethe 330130 series extension cables are the standard connection for both 3300 XL 8 mm and 5 mm proximity transducer systems.\u003cspan\u003e \u003c\/span\u003eEnsure your total system length (probe + extension cable) matches the Proximitor sensor's calibration (typically 5.0 or 9.0 meters).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the armor provide electrical shielding?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe primary purpose of the stainless steel armor is mechanical protection against crushing or cutting.\u003cspan\u003e \u003c\/span\u003eWhile it provides some additional electromagnetic shielding,\u003cspan\u003e \u003c\/span\u003ethe internal coaxial cable is already highly shielded.\u003cspan\u003e \u003c\/span\u003eThe armor should be grounded only at the Proximitor end to avoid ground loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Protector Usage:\u003cspan\u003e \u003c\/span\u003eThe 13 option includes connector protectors.\u003cspan\u003e \u003c\/span\u003eThese are essential for preventing the coaxial connectors from loosening due to machine vibration and for keeping the connection free of environmental contaminants.\u003cspan\u003e \u003c\/span\u003eEnsure they are threaded tightly over the connection point between the probe lead and the extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal System Length Matching:\u003cspan\u003e \u003c\/span\u003eThis 4.5-meter cable is typically paired with a 0.5-meter probe lead to create a 5.0-meter system.\u003cspan\u003e \u003c\/span\u003eIf your Proximitor sensor is calibrated for a 9.0-meter system,\u003cspan\u003e \u003c\/span\u003eusing this cable without additional length will result in significant measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius Constraints:\u003cspan\u003e \u003c\/span\u003eEven with stainless steel armor,\u003cspan\u003e \u003c\/span\u003ethe cable must not be bent tighter than a 25.4 mm (1.0 inch) radius.\u003cspan\u003e \u003c\/span\u003eOver-bending can alter the cable's capacitance and impedance,\u003cspan\u003e \u003c\/span\u003eleading to signal distortion and incorrect vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmor Integrity:\u003cspan\u003e \u003c\/span\u003eInspect the armor for any fraying or sharp breaks during installation.\u003cspan\u003e \u003c\/span\u003eIf the armor is compromised,\u003cspan\u003e \u003c\/span\u003eit can cut into the FEP jacket of the internal cable,\u003cspan\u003e \u003c\/span\u003epotentially grounding the signal and triggering a \"Not OK\" status on the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325003627,"sku":"330130-045-13-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-045-13-cn-e4rsza1xrgs_62c87da1-9d31-4cde-be78-e99a6740bb99.jpg?v=1765521282"},{"product_id":"bently-nevada-330930-065-02-cn-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-02-CN 3300 NSv Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 3300 NSv (Narrow Side view) extension cable designed by Bently Nevada for high-precision proximity transducer systems. The NSv series is specifically engineered for applications where structural constraints or small shaft diameters require a sensor with a narrow magnetic field. This cable acts as the vital signal link between the proximity probe and the Proximitor sensor, maintaining the tuned electrical impedance necessary for accurate vibration and position monitoring. Commonly deployed in centrifugal compressors, small steam turbines, and aero-derivative gas turbines, the 330930-065-02-CN ensures that high-frequency eddy-current signals are transmitted with minimal attenuation, directly contributing to machine safety and the prevention of costly unplanned outages.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model 330930-065-02-CN is defined by its mechanical protection and regional certification options:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330930:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 NSv Extension Cable series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e065:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCable Length Option - 6.5 meters (21.3 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eConnector and Cable Option - Equipped with stainless steel armor for superior mechanical protection, without an external FEP jacket over the armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAgency Approval Option - Country-specific approvals for the China market, ensuring compliance with local industrial safety and hazardous area standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330930-065-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Material\u003c\/td\u003e\n\u003ctd\u003eAISI 302\/304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e6.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg (Cable only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this NSv extension cable with a standard 3300 XL 8 mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 3300 NSv system has different electrical characteristics (inductance and capacitance) compared to the 3300 XL series. Mixing NSv cables with XL probes will result in incorrect scale factors and significant measurement errors. Always match the cable series to the probe and Proximitor type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the stainless steel armor (Option 02)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stainless steel armor provides robust protection against physical damage such as crushing, abrasion, or accidental cutting in harsh industrial environments. It is ideal for installations where the cable is exposed rather than housed in a dedicated conduit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the total system length affect calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBently Nevada proximity systems are tuned to specific total electrical lengths (typically 5 or 9 meters). This 6.5-meter cable must be combined with a probe of the correct lead length to reach the total system length required by the Proximitor sensor. Failure to match these lengths will compromise calibration accuracy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Handling: The miniature coaxial connectors are precision components. Use a connector protector if the junction is located in an area exposed to oil or moisture. Ensure the \"ClickLoc\" mechanism is fully engaged; you should feel a tactile click when the connection is secure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Bend Radius: Even with stainless steel armor, do not exceed the minimum bend radius of 25.4 mm (1.0 inch). Sharp bends can damage the internal coaxial dielectric, leading to signal noise or a \"Not OK\" status on the monitoring rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmor Grounding: Ensure the stainless steel armor is not inadvertently grounded at multiple points, as this can create ground loops that introduce electrical interference into the vibration signal. The system is typically grounded only at the Proximitor sensor end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmor vs. Jacket: Since this model (Option 02) does not have an FEP jacket over the armor, avoid routing the cable through areas where corrosive chemicals could penetrate the stainless steel braid and attack the internal cable insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325101931,"sku":"330930-065-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-065-02-cn-jppv3jwe252_edf75e16-33ff-4f5a-aef8-43b0dc3b4938.jpg?v=1765521285"},{"product_id":"330190-045-01-00-bently-nevada-3300-xl-etr-extension-cable-4-5m-armored","title":"330190-045-01-00 Bently Nevada 3300 XL ETR Extension Cable (4.5m Armored)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330190-045-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical link in the Bently Nevada 3300 XL Proximitor Sensor System. Engineered specifically for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExtended Temperature Range (ETR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments, this extension cable maintains signal integrity where standard cables fail. It facilitates high-precision, non-contact measurements of vibration and axial position in large-scale rotating machinery, including steam turbines, centrifugal compressors, and industrial pumps.\u003c\/p\u003e\n\u003cp\u003eBy utilizing advanced fluoropolymer insulation and a robust mechanical design, this cable ensures the eddy current signal travels from the probe to the Proximitor with minimal attenuation. Its presence within a Machinery Protection System (MPS) guarantees that operators receive real-time, laboratory-grade data to prevent catastrophic equipment failure and optimize maintenance schedules.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330190-045-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a specific alphanumeric logic that defines its physical and mechanical properties:\u003c\/p\u003e\n\u003ch3\u003e330190 - Product Series\u003c\/h3\u003e\n\u003cp\u003eThis designates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Extended Temperature Range (ETR) Extension Cable\u003c\/strong\u003e. It is fully compatible with 3300 XL 8mm probes and Proximitor sensors.\u003c\/p\u003e\n\u003ch3\u003e045 - Cable Length Option\u003c\/h3\u003e\n\u003cp\u003eThis suffix specifies a total length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4.5 meters (14.8 feet)\u003c\/strong\u003e. System accuracy depends on maintaining a total length (probe + extension cable) of either 5.0 or 9.0 meters; this 4.5m cable typically pairs with a 0.5m probe to reach a 5-meter system balance.\u003c\/p\u003e\n\u003ch3\u003e01 - Cable Option\u003c\/h3\u003e\n\u003cp\u003eThe \"01\" designation confirms this is an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eArmored Cable\u003c\/strong\u003e. The stainless steel TFE-jacketed armor provides superior crush resistance and protects the internal coaxial core from mechanical damage in harsh industrial pathways.\u003c\/p\u003e\n\u003ch3\u003e00 - Agency Approval Option\u003c\/h3\u003e\n\u003cp\u003eThis indicates that\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Specific Agency Approvals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(such as ATEX\/IECEx) are required for this particular unit, making it ideal for general-purpose industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8mm Proximity Transducer System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +260°C (-60°F to +500°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 Meters (14.8 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ω Coaxial, Armored (304 Stainless Steel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated Brass \/ Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in) for armored sections\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 Kg (0.66 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDurability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluid resistant, high-moisture tolerance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eProper installation ensures the longevity of the vibration monitoring loop. Follow these engineering best practices:\u003c\/p\u003e\n\u003ch3\u003eConnector Protection\u003c\/h3\u003e\n\u003cp\u003eAlways use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econnector protectors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor heat-shrink tubing to seal the connection between the probe and the extension cable. Moisture ingress at the connector junction is the leading cause of \"glitch\" or signal drift in eddy current systems.\u003c\/p\u003e\n\u003ch3\u003eMinimum Bend Radius\u003c\/h3\u003e\n\u003cp\u003eAvoid sharp kinks. While the armored casing provides protection, exceeding the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25.4 mm (1.0 inch) bend radius\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan damage the internal coaxial dielectric, leading to impedance mismatch and calibration errors.\u003c\/p\u003e\n\u003ch3\u003eSignal Calibration (Gap Voltage)\u003c\/h3\u003e\n\u003cp\u003eAfter connecting the 330190-045-01-00 to the probe and Proximitor, verify the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC Gap Voltage\u003c\/strong\u003e. For a standard 3300 XL 8mm system, a voltage of approximately -10 VDC typically represents the center of the linear range (approx. 1.27 mm or 50 mils gap).\u003c\/p\u003e\n\u003ch3\u003eRouting Precautions\u003c\/h3\u003e\n\u003cp\u003eIsolate the extension cable from high-voltage conduits. Use dedicated grounded metal trays to prevent Electromagnetic Interference (EMI) from distorting the vibration waveform.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330190-045-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrives where standard PVC or FEP cables degrade. Its ETR rating allows for continuous operation near turbine casings and exhaust hoods where temperatures frequently exceed 150°C.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless TSI Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis cable integrates perfectly with Bently Nevada 3500 and 2300 Vibration Monitoring racks, ensuring the transducer system maintains its 7.87 V\/mm (200 mV\/mil) sensitivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 304 stainless steel armor eliminates the need for external conduit in many applications, reducing installation costs while protecting against abrasive dust and accidental impact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced insulation materials prevent capacitance changes during temperature fluctuations, ensuring the vibration data remains accurate from cold start-up to peak operating load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this 4.5m cable with a 1.0m probe in a 5-meter system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. A 5-meter system requires a total length of 5.0 meters. Since this cable is 4.5 meters, it must be paired with a 0.5-meter probe. Pairing it with a 1.0-meter probe would create a 5.5-meter mismatch, causing significant calibration errors in the Proximitor output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the benefit of the \"ETR\" version over the standard 3300 XL cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The ETR (Extended Temperature Range) version uses specialized dielectric materials that withstand up to 260°C. Standard cables are typically rated for lower thresholds. Use the ETR version for sensors located near steam paths or high-heat zones.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the armored option (01) affect the electrical performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No. The armor is a mechanical layer. The internal electrical characteristics remain consistent with the 3300 XL standard, providing the same impedance and frequency response required for high-accuracy vibration monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is this cable backward compatible with the older 3300 8mm (non-XL) systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: While physically compatible in many cases, Bently Nevada recommends using 3300 XL components together to ensure the system meets the published API 670 standards for linearity and accuracy. Mixing XL and non-XL components may result in a non-linear scale factor.\u003c\/p\u003e\n\u003ch2\u003e\u003c\/h2\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325593451,"sku":"330190-045-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330190-045-01-00-uzxo5kqfrix_a5ab24cd-dd36-4dfa-bbf7-96f6bc997297.jpg?v=1765521300"},{"product_id":"330730-080-00-bently-nevada-3300-xl-11mm-extension-cable-8-0m","title":"330730-080-00 Bently Nevada 3300 XL 11mm Extension Cable (8.0m)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730-080-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-precision signal conduit for the Bently Nevada 3300 XL 11mm Proximity Transducer System. This 8.0-meter extension cable bridges the gap between the 11mm probe and the Proximitor® Sensor, maintaining signal integrity over long distances in demanding industrial environments. While 8mm systems handle standard machinery, the 11mm system—and this specific cable—supports applications requiring a wider linear range (up to 4.0 mm \/ 160 mils), such as large steam turbines and axial thrust measurements.\u003c\/p\u003e\n\u003cp\u003eEngineered with advanced fluoropolymer insulation, the 330730-080-00 prevents signal attenuation and electromagnetic interference (EMI). Its low-capacitance design ensures that the high-frequency eddy current oscillations remain stable, providing the monitoring system with a clean, accurate representation of shaft position or vibration. Whether installed in a cable tray or a protective conduit, this cable withstands the extreme thermal cycling typical of power generation and petrochemical facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe model\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730-080-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a strict physical calibration logic to ensure the total system impedance remains within Bently Nevada's performance specifications.\u003c\/p\u003e\n\u003ch3\u003eCable Length (080)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e080\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption designates a total length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8.0 meters (26.2 feet)\u003c\/strong\u003e. In proximity systems, cable length is not arbitrary; the Proximitor® is calibrated for a specific total system length (typically 9.0 meters). When paired with a 1.0-meter probe, this 8.0-meter cable completes the electrical loop perfectly.\u003c\/p\u003e\n\u003ch3\u003eConnector and Cable Option (00)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStandard coaxial cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration without additional stainless steel armor. This version offers maximum flexibility for routing through tight conduits or internal machine housings while utilizing the high-performance FEP (Fluorinated Ethylene Propylene) outer jacket for chemical resistance.\u003c\/p\u003e\n\u003ch3\u003eHigh-Precision Capacitance\u003c\/h3\u003e\n\u003cp\u003eWith a typical capacitance of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e69.9 pF\/m\u003c\/strong\u003e, this cable minimizes phase shifts and signal lag. This electrical precision is what allows Bently Nevada systems to maintain a consistent 3.94 V\/mm (100 mV\/mil) sensitivity across the entire 11mm system's extended range.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 11 mm Proximity System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 Meters (26.2 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +351°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eJacket Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFEP (Fluorinated Ethylene Propylene)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated ClickLoc™ Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 inch)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.36 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eextension cables provide a significant reliability edge for critical asset protection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClickLoc™ Technology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable features gold-plated ClickLoc™ connectors that snap together securely. This \"click\" provides tactile confirmation of a solid connection, preventing the signal \"spiking\" often caused by loose threaded connectors in high-vibration areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Temperature Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FEP jacket remains flexible at -51°C and structurally sound up to +177°C, allowing the cable to be routed near steam lines or in arctic environments without cracking or melting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe outer insulation resists degradation from synthetic lubricants, hydraulic fluids, and most industrial solvents, ensuring a service life measured in decades rather than years.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cp\u003eA proximity system's accuracy is only as good as its cable connections. Follow these engineering best practices:\u003c\/p\u003e\n\u003ch3\u003eTotal System Length Matching\u003c\/h3\u003e\n\u003cp\u003eAlways verify that your total cable length (Probe + Extension) matches the \"System Length\" printed on your Proximitor® Sensor. For this 8.0m cable, you must use a 1.0m probe to reach the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0m system calibration\u003c\/strong\u003e. Mixing 5m and 9m components will cause severe scale factor errors.\u003c\/p\u003e\n\u003ch3\u003eConnector Protection\u003c\/h3\u003e\n\u003cp\u003eWhile the ClickLoc™ connector is robust, it is not waterproof. In environments with high moisture or oil mist, always use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConnector Protectors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(clear plastic sleeves or heat-shrink) to prevent fluid ingress into the coaxial junction.\u003c\/p\u003e\n\u003ch3\u003eProper Routing\u003c\/h3\u003e\n\u003cp\u003eAvoid routing the 330730-080-00 parallel to high-voltage AC power lines. If cross-talk is suspected, ensure the cable is placed in a grounded metal conduit. Never use zip-ties so tight that they deform the cable jacket, as this changes the internal capacitance and ruins the calibration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this 11mm extension cable with an 8mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The 11mm system uses a larger probe tip and a different Proximitor® calibration. The 330730 cable is specifically tuned for the electrical characteristics of the 11mm series. Using it with 8mm components will result in inaccurate readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What happens if I cut the cable to a shorter length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNever cut or splice a proximity extension cable.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe length is an integral part of the tuned circuit. Shortening the cable will change the capacitance, leading to a massive error in the gap voltage and vibration sensitivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is this cable available with stainless steel armor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. While the \"00\" option is standard, the 330730 series can be ordered with \"01\" or \"02\" options for flexible AISI 302 SST armor if the cable will be exposed to physical abrasion or flying debris.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How do I identify a 3300 XL 11mm cable compared to an 8mm cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Most 3300 XL cables look similar, but the 11mm series often features a larger connector body or specific color-coded tags. Always verify the part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the cable's identification label before installation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325757291,"sku":"330730-080-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330730-080-00-wyzpu1y5o5d_b59f7634-1c85-4e60-b4d4-529eb2717eb0.jpg?v=1765521307"},{"product_id":"bently-nevada-330130-080-12-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-080-12-05 | 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-080-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-quality standard extension cable designed for use with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evibration monitoring system. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSA, ATEX, and IECEx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapprovals, this cable ensures reliable and safe operation in a variety of industrial environments. Its fluid-resistant\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFluidLoc\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable design, coupled with a connector protector, offers durability and long-term performance in harsh conditions.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e: Measures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8.0 meters (26.2 feet)\u003c\/strong\u003e, providing optimal flexibility for installations requiring extended cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e: Equipped with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFluidLoc\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable, which includes a connector protector, ensuring secure connections and protection from external contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e: This cable is fully compliant with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATEX\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIECEx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety standards, ensuring it is suitable for use in hazardous environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLightweight\u003c\/strong\u003e: At just\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e34 g\/m (0.4 oz\/ft)\u003c\/strong\u003e, the cable provides easy handling and installation without compromising performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.0 kg\u003c\/strong\u003e, making it efficient for transportation and delivery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplications\u003c\/h4\u003e\n\u003cp\u003eThis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Standard Extension Cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for use in vibration monitoring systems, especially in hazardous locations requiring durable and safe cable solutions. Commonly used in industries such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil \u0026amp; gas\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emining\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical processing\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere environmental conditions demand high-quality, safe cable solutions for extended connections.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330130-080-12-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Protector \u0026amp; Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluidLoc cable with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 g\/m (0.4 oz\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668329754987,"sku":"330130-080-12-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-080-12-05-x023nkb0kyc_78817f9f-f053-4f21-9dd5-f62b6e05f577.jpg?v=1765521399"},{"product_id":"bently-nevada-330130-070-01-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-070-01-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330130-070-01-CN (330130)\u003c\/strong\u003e is a heavy-duty, armored proximity extension cable designed for the Bently Nevada 3300 XL 8 mm Proximity Transducer System. This cable provides critical signal transmission between a 3300 XL proximity probe and a 3300 XL Proximitor Sensor, allowing for precise static and dynamic measurements of rotating machinery. Widely utilized in high-reliability industrial applications such as fluid-film bearing monitors, compression systems, and high-speed turbine shafts, it plays an important role in delivering data for vibration tracking and Keyphasor speed references. Its robust engineering shields delicate eddy current signals from harsh plant conditions, which enhances monitoring uptime and contributes directly to continuous machinery operation and significant downtime reduction.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model configuration for the \u003cstrong\u003e330130-070-01-CN\u003c\/strong\u003e is defined by the following technical suffixes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e070 (Cable Length Option):\u003c\/strong\u003e Configured for a length of 7.0 meters (22.9 feet), designed to establish the precise capacitance needed for an accurate 7-meter or 9-meter total system loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01 (Connector Protector and Cable Option):\u003c\/strong\u003e Equipped with an integrated stainless steel armored jacket for superior mechanical protection against physical damage and crushing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCN (Agency Approval Option):\u003c\/strong\u003e Indicates country-specific regulatory approvals optimized for compliance within the Chinese industrial market.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330130-070-01-CN\u003c\/strong\u003e architecture is optimized to deliver consistent electrical impedance and low capacitance to prevent signal distortion over long distances. It utilizes advanced gold-plated \"click\" type coaxial connectors that supply a secure mechanical lock and maintain continuous electrical connection under severe industrial vibration. The internal coaxial cable is wrapped in a rugged flexible armor that protects the internal dielectric material from hot turbine oil and physical stress. This configuration allows complete unit and cabling interchangeability across the 3300 XL platform, eliminating the need for tedious field calibration when replacing individual sensor elements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e330130-070-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e7.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eCable Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eStainless steel armor jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e69.9 pF\/m typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eCore Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e1.54 ± 0.23 Ohm at 7.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this extension cable be used directly with a standard non-XL 3300 probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \u003cstrong\u003e330130-070-01-CN\u003c\/strong\u003e is backward compatible and interchangeable with non-XL 3300 series 5 mm and 8 mm transducer components. However, for optimum performance and lowest interchangeability error, a full 3300 XL component setup is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the silicone tape included with the cable suitable for all installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSilicone tape is often provided for connector protection in dry conditions to prevent moisture ingress. It is not recommended for applications where the probe-to-cable connection is continuously exposed to or submerged in turbine oil, as petroleum products can degrade the tape over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is matching the 7.0 meters cable length critical for the Proximitor Sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Proximitor Sensor is calibrated based on a precise total electrical length (typically 5.0 meters or 9.0 meters). Mismatching a 7.0 meters extension cable with an incorrect probe length or sensor calibration will alter the loop capacitance, introducing severe scale factor errors into your vibration metrics.\u003c\/p\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Torque and Mechanical Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen joining the extension cable to the proximity probe, ensure the gold-plated coaxial connectors are clean and free of debris. The \"click\" type connectors should be securely locked. For standard finger-tight connections, avoid over-tightening with heavy tools as this can strip the thin gold plating or warp the internal pin, which impacts the nominal 50 Ohm output resistance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius and Routing Constraints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo prevent kinking the inner core conductor and damaging the armor, always maintain a minimum bend radius of 25.4 mm during field routing. Avoid pulling the armored cable around sharp structural steel corners or exposing it to heavy foot traffic without adequate cable trays or channel protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Noise Separation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe outer stainless steel armor of the \u003cstrong\u003e330130-070-01-CN\u003c\/strong\u003e must be kept isolated from the local machine ground along its run to prevent ground loops. Ensure that the signal run is isolated from high-voltage motor power leads, variable frequency drives (VFDs), and heavy switching relays to eliminate electromagnetic noise from coupling into the high-frequency proximity loop.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668337684843,"sku":"330130-070-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-070-01-cn-0qddsa0ikfg_acf0f322-9e4a-4e1a-8b21-0b0ff0cb7b1a.jpg?v=1765521475"}],"url":"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-xl-extension-cables.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}