{"title":"Bently Nevada 7200 \u0026 3300 Interconnect Cables","description":"\u003cp\u003eBently Nevada 7200 \u0026amp; 3300 Interconnect Cables are specialized wiring solutions designed to maintain compatibility and signal integrity across different generations of monitoring hardware. The architecture includes high-quality shielding and specific connector terminations that bridge the gap between legacy \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-system-monitoring\"\u003e3300 system monitoring\u003c\/a\u003e units and modern sensors. Technical characteristics feature low resistance and high-dielectric strength, ensuring that raw vibration signals are transmitted without noise interference. Functionally, these cables allow plants to maintain older machinery protection systems while integrating newer \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-xl-proximitor-sensor\"\u003e3300 XL Proximitor sensors\u003c\/a\u003e or seismic transducers. They serve as a critical link in the monitoring chain, ensuring that data from the machine floor reaches the control room accurately, supporting long-term asset lifecycle management.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-9571-50-standard-interconnect-cable","title":"Bently Nevada 9571-50 Standard Interconnect Cable","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9571-50\u003c\/strong\u003e is a standard interconnect cable designed for use with industrial vibration monitoring and transducer systems. The cable assembly includes a moisture-resistant female connector at the transducer end and ring lugs at the monitor end for direct field wiring termination.\u003c\/p\u003e\n\u003cp\u003eThe cable uses shielded 0.382 mm2 (22 AWG) conductors to support stable signal transmission in electrically noisy industrial environments. The shielding construction assists with EMI\/RFI mitigation in machinery monitoring installations.\u003c\/p\u003e\n\u003cp\u003eThis interconnect cable is intended for connection between vibration transducers and monitoring equipment in rotating machinery applications including turbines, pumps, compressors, motors, and general condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe assembly supports installation in industrial environments requiring moisture resistance and extended operating temperature capability.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eShielded 0.382 mm2 (22 AWG) cable\u003c\/li\u003e\n\u003cli\u003eMoisture-resistant female connector\u003c\/li\u003e\n\u003cli\u003eRing lug termination at monitor end\u003c\/li\u003e\n\u003cli\u003eIndustrial transducer interconnect design\u003c\/li\u003e\n\u003cli\u003eEMI\/RFI shielding support\u003c\/li\u003e\n\u003cli\u003eFlexible field installation\u003c\/li\u003e\n\u003cli\u003eExtended temperature range\u003c\/li\u003e\n\u003cli\u003eCompatible with vibration monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVibration monitoring systems\u003c\/li\u003e\n\u003cli\u003eProximity transducer connections\u003c\/li\u003e\n\u003cli\u003eMachinery protection systems\u003c\/li\u003e\n\u003cli\u003eTurbine monitoring installations\u003c\/li\u003e\n\u003cli\u003eCompressor monitoring systems\u003c\/li\u003e\n\u003cli\u003eMotor condition monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating equipment\u003c\/li\u003e\n\u003cli\u003eProcess plant instrumentation\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance systems\u003c\/li\u003e\n\u003cli\u003ePermanent mounted monitoring installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e9571-AA: Standard Interconnect Cable\u003c\/li\u003e\n\u003cli\u003e-50: 50 ft (15.2 m) cable length option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eElectricalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eShielded cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eConductor Size\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eEnvironmentalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-29 to 121 degC (-20 to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMoisture Resistance\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eMoisture-resistant connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eMechanicalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eFemale connector at transducer end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMonitor End Termination\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eMinimum Length\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e2 ft (0.60 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMaximum Length\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eGeneralSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eStandard Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eTransducer Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eConnections\/Interfaces\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eConnector PinFunction\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eFemale Connector\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eTransducer connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eRing Lugs\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eMonitor termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cp\u003eRoute the cable separately from high-voltage motor wiring and variable frequency drive output cables to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eMaintain cable shielding continuity throughout the installation to support signal integrity.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive cable bending near the connector termination points during installation.\u003c\/p\u003e\n\u003cp\u003eSecure the cable properly to minimize vibration-related mechanical stress.\u003c\/p\u003e\n\u003cp\u003eVerify ring lug tightening torque during monitor termination work.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing surfaces before installation in moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eUse appropriate cable routing practices to prevent abrasion or pinch damage.\u003c\/p\u003e\n\u003cp\u003eAvoid extending the cable beyond the specified maximum length.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the conductor size of this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable uses 0.382 mm2 (22 AWG) conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of shielding is provided?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe assembly uses shielded cable construction for industrial signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat connector is installed at the transducer end?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA moisture-resistant female connector is installed at the transducer end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the monitor end terminated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor end uses ring lug terminations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum supported cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum specified length is 99 ft (30 m).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum available cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe minimum specified length is 2 ft (0.60 m).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the cable be used in industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The cable is intended for industrial vibration monitoring installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the cable support EMI\/RFI mitigation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shielded construction assists with EMI\/RFI reduction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat systems is the cable intended for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is intended for transducer and vibration monitoring system connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the cable be used outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe connector is moisture resistant, but installation suitability depends on enclosure and site conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat temperature range is supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified operating range is -29 to 121 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable suitable for permanent installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is suitable for permanently mounted machinery monitoring systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666624344427,"sku":"9571-50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-50-standard-interconnect-cable-tfd2n403jen_f9932837-544b-41d4-9e0b-edfee3645b51.jpg?v=1765444312"},{"product_id":"bently-nevada-89477-25-standard-armored-interconnect-cable","title":"Bently Nevada 89477-25 Standard Armored Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 89477-25\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003eStandard Armored Interconnect Cable\u003c\/strong\u003e designed specifically for critical machinery protection and condition monitoring systems. Engineered with a rugged right-angle connector interface, this cable provides reliable signal transmission between proximity probes, sensors, and monitoring modules within the \u003cstrong\u003eBently Nevada Proximitor Sensor Systems\u003c\/strong\u003e. The integrated armor casing ensures robust mechanical protection against physical damage, abrasion, and environmental hazards common in demanding industrial processing areas. By facilitating precise, low-attenuation signal delivery, it supports accurate vibration, position, and speed measurements for high-speed rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRight-angle connector configuration for low-profile installation in tight clearances\u003c\/li\u003e\n\u003cli\u003eIntegrated standard armor cladding for superior mechanical and environmental protection\u003c\/li\u003e\n\u003cli\u003ePre-cut length optimized to maintain signal integrity and calibration accuracy\u003c\/li\u003e\n\u003cli\u003eDurable construction resistant to industrial fluids, oils, and physical stress\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring systems\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating compressor diagnostics\u003c\/li\u003e\n\u003cli\u003eLarge industrial pumps, fans, and electric motor shaft displacement measurement\u003c\/li\u003e\n\u003cli\u003eHydroelectric generator air gap and vibration sensing setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight Angle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 Feet (approximately 7.6 Metres)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.15 kg (approximate based on standard armoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.6 Metres total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Maintenance\u003c\/strong\u003e: Avoid bending the armored section beyond the minimum specified bend radius to prevent damage to the internal conductors and armoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Routing\u003c\/strong\u003e: Ensure the right-angle connector is oriented properly before tightening to eliminate structural stress on the sensor connection point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Route the interconnect cable away from high-voltage conduits, variable frequency drives (VFDs), and alternating current (AC) power lines to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection\u003c\/strong\u003e: Ensure all connection interfaces are clean, dry, and properly sealed during installation to avoid moisture ingress and signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the right-angle connector on this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe right-angle design allows for secure connections in confined spaces where straight connectors would face excessive mechanical strain or clearance interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used with any proximity probe system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is specifically designed to integrate with compatible Bently Nevada proximity probe and Proximitor sensor systems matching the required connection footprint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the armoring protect against chemical exposure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard armor provides excellent mechanical protection against physical impacts and abrasion, while also offering resistance to common industrial oils and moisture under standard operating conditions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666733461867,"sku":"89477-25","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-89477-25-interconnect-cable-zyyj4ofhkb0_ee5e8dba-aa63-42b7-a111-1d4ccb7e7d30.jpg?v=1765446724"},{"product_id":"bently-nevada-9571-30-interconnect-cable","title":"Bently Nevada 9571-30 Standard Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9571-30\u003c\/strong\u003e is a heavy-duty, shielded \u003cstrong\u003einterconnect cable\u003c\/strong\u003e designed for critical machinery protection and vibration monitoring systems. It establishes a reliable signal transmission pathway between High Temperature Velocity Sensors (HTVS) and monitoring systems, ensuring the integrity of dynamic vibration data in harsh industrial environments. The cable features advanced shielding to minimize electromagnetic interference and a moisture-resistant termination to maintain electrical performance under demanding conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated moisture-resistant female connector at the HTVS termination point\u003c\/li\u003e\n\u003cli\u003ePre-terminated ring lugs at the monitor end for secure terminal block installation\u003c\/li\u003e\n\u003cli\u003eRobust shielding to protect low-level signals from EMI and RFI noise\u003c\/li\u003e\n\u003cli\u003eWide operating temperature rating for deployment in extreme industrial climates\u003c\/li\u003e\n\u003cli\u003eFlexible 22 AWG conductors optimizing signal conductivity and mechanical durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring\u003c\/li\u003e\n\u003cli\u003ePower generation facility machinery protection\u003c\/li\u003e\n\u003cli\u003ePetrochemical plant rotating equipment diagnostics\u003c\/li\u003e\n\u003cli\u003eHigh-temperature industrial fan and blower monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9571-AA\u003c\/td\u003e\n\u003ctd\u003eStandard Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-30\u003c\/td\u003e\n\u003ctd\u003e30 Feet = 9.0 Metres (approx.) length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9571-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eStandard Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eShielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type A (HTVS End)\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type B (Monitor End)\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 degC (-20 to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e30 Feet (approx. 9.0 Metres)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eAvailable upon request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e30 Feet length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection:\u003c\/strong\u003e Ensure the moisture-resistant female connector is fully seated and sealed at the HTVS end to prevent water ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the cable through dedicated conduit or cable trays away from high-voltage AC power lines to mitigate EMI\/RFI noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain the minimum recommended bend radius during installation to prevent damage to the internal 22 AWG conductors and shielding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Connect the cable shield in accordance with the specific monitoring system diagram, typically grounding at the monitor end only to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connections:\u003c\/strong\u003e Secure the pre-terminated ring lugs firmly to the monitor terminal blocks to ensure a vibration-proof electrical connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of sensor connects to the 9571-30 cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is specifically configured to interface with High Temperature Velocity Sensors (HTVS) on one end and standard machinery monitoring systems on the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this interconnect cable withstand outdoor industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the cable construction incorporates a moisture-resistant female connector and a rugged outer jacket rated for temperatures up to 121 degC, making it suitable for demanding industrial deployments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the shield terminated on this specific cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor end is fitted with ring lugs which accommodate standard grounding practices on monitor terminal strips, while the sensor end features a specialized shielded interface within the female connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to obtain this cable in lengths other than 30 feet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNon-standard and custom lengths can be ordered from the manufacturer using the 9571-AA configuration logic at additional cost.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666733691243,"sku":"9571-30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-30-interconnect-cable-yfe2hoqlxvu_60641b4b-4792-470b-853b-c190d2b0a9ca.jpg?v=1765446728"},{"product_id":"bently-nevada-16710-33-interconnect-cable-with-armor","title":"Bently Nevada 16710-33 Interconnect Cable with Armor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-33\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterconnect cable with armor from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis designed for secure signal transmission in machinery protection and vibration monitoring systems operating in harsh industrial environments. It is widely deployed in turbines, compressors, pumps, generators, and large rotating equipment installed in refinery, petrochemical, offshore, and power generation facilities where mechanical stress, oil exposure, and continuous vibration are present.\u003c\/p\u003e\n\u003cp\u003eThis armored interconnect cable provides reinforced mechanical protection for signal wiring used between proximity probes, proximitor modules, junction boxes, and monitoring systems. The 33 ft length supports flexible installation in medium-range equipment layouts while maintaining stable signal integrity in electrically noisy environments. The armored construction reduces the risk of abrasion, crushing, and mechanical fatigue, ensuring long service life in demanding industrial installations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 16710 series uses an armored cable structure designed to improve mechanical durability and environmental resistance in field installations.\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e16710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength Option\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial protective armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eInterconnect signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery protection systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Environment\u003c\/td\u003e\n\u003ctd\u003eHigh vibration, oil exposure, industrial plants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe armored layer provides mechanical shielding against external impact and cable wear, making it suitable for routing in areas with moving machinery, sharp structural edges, and high vibration loads. It is engineered to maintain consistent electrical performance while reducing signal degradation caused by mechanical stress.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16710-33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable with Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C (typical industrial cable range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring and machinery protection systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main purpose of armored construction in this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe armor provides mechanical protection against abrasion, crushing, and external impact in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the 16710-33 cable typically used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is used in machinery monitoring systems connecting probes, modules, and junction boxes in rotating equipment installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high vibration areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The armored design is specifically intended for high vibration industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable electrically active?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. It is a passive interconnect cable used for signal transmission only.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Engineering Recommendations\u003c\/h3\u003e\n\u003cp\u003eInstall the cable with proper strain relief to prevent mechanical stress transfer into connector termination points.\u003c\/p\u003e\n\u003cp\u003eAvoid routing near high-voltage power cables or VFD output lines to reduce electromagnetic interference in signal transmission.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius during installation to preserve conductor integrity under continuous vibration conditions.\u003c\/p\u003e\n\u003cp\u003eSecure armored sections using industrial cable clamps to ensure stable positioning in moving or high-vibration machinery areas.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666760528235,"sku":"16710-33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-33-interconnect-cable-3s1vfoeywic_fb947b41-3b19-4835-8272-260ec1e3ba41.jpg?v=1765447126"},{"product_id":"bently-nevada-9571-10-two-conductor-twisted-shielded-interconnect-cable","title":"Bently Nevada 9571-10 Two-Conductor Twisted Shielded Interconnect Cable","description":"\u003cp\u003eThe \u003cstrong\u003e9571\u003c\/strong\u003e instrumentation interconnect cable, complete part number \u003cstrong\u003e9571-10\u003c\/strong\u003e, is a high-performance two-conductor 22 AWG shielded cable assembly designed for transmitting dynamic vibration signals within machinery protection systems. The physical construction features a moisture-resistant two-socket female connector at the sensor termination end to maintain electrical insulation in humid environments, while the monitor termination end is fitted with standard terminal lugs for robust installation into I\/O chassis backplanes. This 10 ft (3.05 m) twisted-pair configuration provides superior differential noise rejection, ensuring precise signal transmission from compatible transducers directly to Bently Nevada machinery monitors. This cable is explicitly not designed for integration within the 21128 Velocity Transducer Housing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10: Cable Length Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e10 ft (3.05 m) nominal cable length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwisted, shielded pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-socket moisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.05 m (10 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 m (2.0 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 m (99 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Constraints\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot for use with 21128 Velocity Transducer Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 22 AWG twisted-pair geometry provides high noise immunity against electro-magnetic interference by canceling out differential-mode noise along the signal pathway.\u003c\/li\u003e\n\u003cli\u003eThe sensor-end termination utilizes a specialized moisture-resistant compound within the 2-socket female connector housing to prevent moisture ingress from degrading insulation resistance.\u003c\/li\u003e\n\u003cli\u003eTotal loop resistance and cable capacitance scale linearly with length; ensure overall parameters align with monitoring system input barriers to maintain accurate high-frequency data transfer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the cable shield drain wire exclusively to the instrument rack instrumentation ground bar, and completely isolate the shield at the transducer end to prevent structural ground loops.\u003c\/li\u003e\n\u003cli\u003eRoute the signal cable away from high-voltage AC electric motor supply cables, variable frequency drives (VFDs), and heavy inductive switching elements to maintain raw signal integrity.\u003c\/li\u003e\n\u003cli\u003eAdhere strictly to industrial minimum bending radius standards during conduit routing to prevent physical degradation of the internal shield foil and 22 AWG copper strands.\u003c\/li\u003e\n\u003cli\u003eEnsure the moisture-resistant connector is fully locked and sealed against the sensor body to guarantee long-term environmental protection and reliable contact interface.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666765181291,"sku":"9571-10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-10-interconnect-cable-xuptdzcpsz4_41f1678f-55d2-4cbd-834c-67e79130ed61.jpg?v=1765447211"},{"product_id":"bently-nevada-84661-82-standard-armored-interconnect-cable","title":"Bently Nevada 84661-82 Standard Armored Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 84661-82\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003eStandard Armored Interconnect Cable\u003c\/strong\u003e designed for critical signal transmission in industrial machinery protection and vibration monitoring systems. It features a rugged stainless steel armor wrapped over a shielded 0.382 mm2 (22 AWG) conductor core, providing excellent mechanical protection against physical damage and environmental hazards. The assembly is built with a moisture-resistant female connector at the High Temperature Velocity Sensor (HTVS) end and ring lugs at the monitor terminal end, ensuring secure, low-loss connectivity to continuous monitoring modules. Engineered to operate reliably across a temperature range of -29 to 121 Celsius, this cable is highly optimized for deployment with high-reliability sensors in harsh industrial monitoring environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel outer armoring for superior crush and abrasion resistance\u003c\/li\u003e\n\u003cli\u003eMoisture-resistant female terminal connector configured for HTVS applications\u003c\/li\u003e\n\u003cli\u003ePre-terminated ring lugs at the monitor interface for secure terminal block connection\u003c\/li\u003e\n\u003cli\u003eShielded 22 AWG core construction to minimize electrical noise and signal attenuation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring loops\u003c\/li\u003e\n\u003cli\u003eIndustrial compressor and expander casing velocity measurements\u003c\/li\u003e\n\u003cli\u003eHeavy-duty pump and fan vibration telemetry\u003c\/li\u003e\n\u003cli\u003eHigh-temperature processing areas requiring ruggedized physical cable shielding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.382 mm2 (22 AWG), shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor End Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector (HTVS end)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 Celsius (-20 to 250 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 Feet (approx. 24.6 Metres)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Ensure the shield drain wire or shielded component is correctly referenced to the designated monitor ground terminal to prevent ground loops and mitigate EMI\/RFI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Constraints\u003c\/strong\u003e: Do not force sharp bends or kinks in the stainless steel armoring during routing, as this can pinch internal conductors and rupture the protective shield.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection\u003c\/strong\u003e: Verify that the moisture-resistant female connector interface is fully seated and properly sealed at the HTVS end to prevent fluid ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Keep the path of the interconnect cable separate from high-voltage motor lines or switching control wires to protect the accuracy of low-level analog signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat sensor types link with this specific cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable is constructed with a moisture-resistant female terminal configuration explicitly intended for connection to High Temperature Velocity Sensors (HTVS) on the machine end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the monitor end interface connect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor end uses pre-installed ring lugs, which allow for a secure, bolt-down termination onto standard terminal blocks inside monitor enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the armored jacket withstand high-temperature processing zones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the components of this assembly are rated to sustain continuous exposure to industrial environments with ambient operational temperatures ranging from -29 to 121 Celsius.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666768195947,"sku":"84661-82","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-84661-82-velomitor-interconnect-cable-ohizj0hpw1b_1972d5ed-07ac-44bf-b813-1668d8ec3403.jpg?v=1765447242"},{"product_id":"bently-nevada-cb2w100-064-interconnect-cable","title":"Bently Nevada CB2W100-064 Interconnect Cable","description":"\u003ch3\u003eTechnical Summary\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada CB2W100-064 is a 64 feet (19.5 meters) interconnect cable engineered for transmitting dynamic vibration and acceleration signals within machinery protection systems. It establishes a secure, low-noise signal path between industrial transducers and monitoring mainframes, minimizing electromagnetic interference (EMI) and preventing signal attenuation or false trips. The cable utilizes a twisted-pair architecture with a dedicated shield to maintain signal integrity over long-distance runs in harsh electromagnetic environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB2W100\u003c\/strong\u003e: Product series designation for premium, high-temperature dynamic signal interconnect cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-064\u003c\/strong\u003e: Specifies the exact physical length of the cable assemble, designated as 64 feet (equivalent to 19.5 meters).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors\u003c\/strong\u003e: Features a MIL-C 5015 standard 2-socket connector at the sensor end with splash-proof isolation, transitioning to a blunt-cut termination at the monitor\/junction box end.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductors\u003c\/strong\u003e: 20 AWG twisted pair copper conductors optimized for low electrical resistance and high tensile strength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding\u003c\/strong\u003e: Integrated braided or foil shield providing continuous coverage against radio frequency and electrostatic noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJacket Material\u003c\/strong\u003e: High-durability yellow Teflon (FEP) insulation offering superior chemical resistance and thermal stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCB2W100-064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eCable Length\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e64 feet (19.5 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eConductor Gauge\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e20 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eTwisted pair, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eConnector A\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eMIL-C 5015, 2 Socket, Premium, Splash Proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eConnector B\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eBlunt cut \/ Flying leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eJacket Material\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eYellow Teflon (FEP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e-55 to +200 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eCore Application\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eTransducer-to-rack analog signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How should the shield wire of the CB2W100-064 be terminated to avoid ground loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shield must be grounded at one single point, typically at the monitor rack or structural ground inside the junction box. Leave the shield floating and isolated at the transducer end using the premium isolated MIL-C 5015 connector housing to prevent circulating ground currents from corrupting the vibration signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this cable be used with proximity probe systems or is it strictly for accelerometers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis 2-socket MIL-C 5015 configuration is primarily designed for 2-wire accelerometers and velocity sensors. Standard proximity probes require 3-wire extension cables (such as the 3300 XL series). Verify transducer pinning before deployment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum temperature rating for the yellow Teflon jacket?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Teflon (FEP) jacket is rated for continuous operation from -55 to +200 deg C, making it suitable for routing near hot casing surfaces on steam turbines, gas turbines, and compressors.\u003c\/p\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMaintain a minimum bend radius of 75 mm during installation to prevent internal conductor fatigue or damage to the Teflon insulation layer.\u003c\/li\u003e\n\u003cli\u003eRoute the cable through dedicated, grounded metal conduit when deploying across open structural spans to provide mechanical protection and secondary EMI shielding.\u003c\/li\u003e\n\u003cli\u003eSecure the MIL-C 5015 threaded connector to the sensor housing using a calibrated torque wrench, ensuring the splash-proof seal is fully compressed without over-tightening.\u003c\/li\u003e\n\u003cli\u003eKeep the interconnect cable isolated from high-voltage AC power lines by a minimum clearance of 300 mm to eliminate cross-talk and induction noise on the low-voltage AC\/DC vibration signal.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668291383659,"sku":"CB2W100-064","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cb2w100-064-vsz41w0zaev_fe968a98-9d74-40cc-88e5-e1f3d7075186.jpg?v=1765520349"},{"product_id":"bently-nevada-106765-04-interconnect-cable-1","title":"Bently Nevada 106765-04 Interconnect Cable","description":"\u003ch3\u003eTechnical Summary\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e106765-04\u003c\/strong\u003e is a 4-meter interconnect cable engineered for transmitting dynamic eddy current sensor signals within the 3300 Proximity Transducer System. It establishes a dedicated electrical pathway linking the Proximitor Sensor to the 3300 rack monitor. The hardware minimizes signal attenuation and impedance mismatch, preventing RF reflections and phase shifts across the 24.3 mV\/um or 7.87 V\/mm scale factor. This shielding architecture blocks electromagnetic interference (EMI) to isolate critical vibration frequencies, eliminating reading drift and preventing false machine trips during high-frequency rotor dynamics tracking.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e106765\u003c\/strong\u003e - Base model identifier for high-performance coaxial interconnect cables optimized for Bently Nevada proximity systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04\u003c\/strong\u003e - Defines the specific physical length configuration representing 4.0 meters (13.1 feet) of overall cable length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e106765-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCoaxial, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003ePhysical Length\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e3300 Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e4.0 meters (length) x 3.2 mm (diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003ePassive device (0.0 mW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eImpedance\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e75.0 ohms nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eConnector Material\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eGold-plated brass (ClickLoc style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e Can the 106765-04 cable be modified or spliced in the field if the length is excessive?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Splicing or cutting this coaxial cable alters the total system capacitance and electrical length, which destroys the calibrated 7.87 V\/mm (200 mV\/mil) scale factor. Excess length must be looped and secured, not removed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e Is the 106765-04 directly compatible with the newer 3300 XL series Proximitor sensors?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It interfaces physically with 3300 XL hardware, but using the non-XL 106765 cable with an XL Proximitor limits system performance to legacy 3300 standards and may introduce minor linearity discrepancies. Use 3300 XL series extensions for full XL specs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What occurs if the coaxial connectors encounter moisture or oil contamination inside a conduit?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Liquid ingress causes cross-talk or insulation breakdown, shifting the gap voltage reading toward zero VDC and generating false probe fault alerts. Seal connections with silicone tape or fluid-tight terminal boxes.\u003c\/p\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm during installation. Avoid sharp bends or kinks that displace the internal dielectric layer and degrade signal propagation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Circuitry:\u003c\/strong\u003e Terminate the outer shield braid strictly at the monitor rack chassis ground. Leave the field sensor end floating inside an isolated terminal block to prevent ground loops that superimpose 50\/60 Hz noise onto the vibration signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Torque:\u003c\/strong\u003e Hand-tighten the coaxial connectors until the internal lock clicks. Apply a single drop of non-conductive thread-locking compound if operating under extreme structural vibration profiles; do not use pliers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Verification:\u003c\/strong\u003e Post-installation, verify the static gap voltage measures between -9.0 VDC and -11.0 VDC (nominal target -10.0 VDC) using a digital multimeter at the terminal block to confirm correct electrical length match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668291416427,"sku":"106765-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/106765-04-cldsrqajcgv_54326de0-3c18-4910-a66f-d540f4974baa.jpg?v=1765520350"},{"product_id":"bently-nevada-cb2w100-112-interconnect-cable","title":"Bently Nevada CB2W100-112 Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCB2W100-112\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterconnect cable from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis designed for long-distance signal transmission within industrial machinery protection and vibration monitoring systems. This cable is commonly installed between proximity probes, monitoring modules, junction boxes, and condition monitoring equipment used on steam turbines, centrifugal compressors, generators, pumps, and large rotating machinery operating in refinery, petrochemical, mining, and power generation facilities.\u003c\/p\u003e\n\u003cp\u003eThe 112 ft cable length supports extended routing requirements inside large process plants where monitoring cabinets are positioned far from rotating assets. Bently Nevada designs the CB2W100 series for stable signal integrity in electrically noisy industrial environments exposed to vibration, oil contamination, heat, and continuous mechanical operation. The cable construction supports reliable communication between field transducers and monitoring systems, helping maintenance teams maintain accurate machinery condition data and reduce unplanned shutdown events caused by signal instability or wiring failures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCB2W100\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e112\u003c\/td\u003e\n\u003ctd\u003e112 ft cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetric Length Equivalent\u003c\/td\u003e\n\u003ctd\u003e34.1 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCable Design and Application Details\u003c\/h3\u003e\n\u003cp\u003eThe CB2W100 series is engineered for industrial machinery monitoring installations requiring stable low-noise signal transmission over extended cable distances. The cable supports integration with Bently Nevada vibration monitoring systems commonly installed on API rotating equipment.\u003c\/p\u003e\n\u003cp\u003eIts industrial-grade construction helps resist environmental stress caused by continuous machine vibration, oil exposure, and elevated ambient temperatures commonly found in turbine halls and compressor stations. The long cable length allows flexible routing between field instrumentation and centralized monitoring cabinets without requiring additional intermediate connections.\u003c\/p\u003e\n\u003cp\u003eThe cable is widely used in condition monitoring applications where maintaining signal reliability remains critical for predictive maintenance and machinery protection performance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCB2W100-112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e112 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Metric\u003c\/td\u003e\n\u003ctd\u003e34.1 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery protection and vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Area\u003c\/td\u003e\n\u003ctd\u003eTurbines, compressors, motors, generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eSuitable for industrial process environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Routing\u003c\/td\u003e\n\u003ctd\u003eLong-distance industrial signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary use of the CB2W100-112 cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable is used for signal transmission between field transducers and Bently Nevada machinery monitoring systems installed on rotating equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be installed in refinery and power plant environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The cable is designed for industrial environments with vibration, heat, and continuous machinery operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the total cable length of this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis version provides a total cable length of 112 ft, equivalent to approximately 34.1 metres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the CB2W100-112 suitable for long cable routing applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The extended cable length supports installations where monitoring cabinets are located far from machinery assets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines and Field Recommendations\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from high-voltage motor conductors and VFD output wiring to minimize electromagnetic interference within machinery monitoring circuits.\u003c\/p\u003e\n\u003cp\u003eUse vibration-resistant cable clamps when installing near turbines, compressors, or large motors. Unsupported cable sections may experience long-term mechanical fatigue under continuous vibration conditions.\u003c\/p\u003e\n\u003cp\u003eInspect cable routing paths for sharp metal edges and excessive heat exposure before commissioning. Continuous abrasion or thermal stress may reduce cable service life in industrial process environments.\u003c\/p\u003e\n\u003cp\u003eFor outdoor installations, use sealed conduit systems and industrial-grade cable protection methods to prevent moisture intrusion and environmental contamination.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668300525931,"sku":"CB2W100-112","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CB2W100-112-4ygb2clpbnh_3367adcb-ed88-4a38-b1b8-adeb828f4be5.jpg?v=1765520524"},{"product_id":"bently-nevada-cb2w100-32-interconnect-cable","title":"Bently Nevada CB2W100-32 Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCB2W100-32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterconnect cable from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis designed for industrial vibration monitoring and machinery protection systems operating in demanding process environments. This cable assembly uses MIL-C 5015 splash-proof connectors with a 2-socket configuration and supports reliable signal transmission between proximity probes, monitoring modules, and field instrumentation installed on turbines, compressors, pumps, and large rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThe cable features 20 AWG twisted pair conductors with shielding and a yellow Teflon jacket engineered for high-temperature industrial applications where oil exposure, vibration, and electromagnetic interference are common. Bently Nevada includes the locking ring, adapter seal, and O-ring to improve environmental sealing and connector stability during long-term field operation. The 32 ft cable length supports flexible routing inside turbine enclosures, compressor skids, motor control areas, and refinery monitoring cabinets while maintaining stable signal integrity across critical machinery protection circuits.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCB2W100\u003c\/td\u003e\n\u003ctd\u003eMIL-C 5015 splash-proof interconnect cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e32 ft cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Metric Equivalent\u003c\/td\u003e\n\u003ctd\u003e9.75 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCable Construction and Connector Design\u003c\/h3\u003e\n\u003cp\u003eThe CB2W100 series uses twisted pair shielded conductors to reduce electrical noise interference in high-electromagnetic industrial environments. The yellow Teflon cable jacket provides improved resistance against heat, oil contamination, abrasion, and chemical exposure commonly found near rotating equipment installations.\u003c\/p\u003e\n\u003cp\u003eThe cable assembly includes MIL-C 5015 2-socket connectors with splash-proof construction for industrial field reliability. The isolated blunt-cut termination configuration simplifies custom field integration into monitoring cabinets and junction assemblies. Included locking hardware improves connector retention under continuous machine vibration conditions.\u003c\/p\u003e\n\u003cp\u003eThis cable is commonly deployed within Bently Nevada machinery protection systems used in refinery process trains, power generation equipment, LNG facilities, and offshore rotating machinery installations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCB2W100-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMIL-C 5015, 2 Socket, Splash-Proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e20 AWG twisted pair, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003eYellow Teflon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eIsolated to blunt cut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd\u003eLocking ring, adapter seal, O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e32 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Metric\u003c\/td\u003e\n\u003ctd\u003e9.75 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eSuitable for industrial high-temperature environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery protection and vibration monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat monitoring systems use the CB2W100-32 cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable is commonly used with Bently Nevada vibration monitoring systems, proximity probe installations, and rotating machinery protection applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the cable include field installation hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The assembly includes a locking ring, adapter seal, and O-ring for improved connector sealing and retention.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of shielding does this cable use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable uses twisted pair shielded conductors to reduce electromagnetic interference in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable operate near turbines and compressors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The Teflon jacket and industrial connector design support installation in high-temperature and high-vibration machinery areas.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines and Engineering Recommendations\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from high-voltage motor power wiring and VFD output cables to minimize electrical noise interference within machinery protection circuits.\u003c\/p\u003e\n\u003cp\u003eDuring installation, avoid excessive cable bending near connector termination points. Tight bending radius conditions may reduce long-term conductor reliability in continuous vibration environments.\u003c\/p\u003e\n\u003cp\u003eInspect locking ring engagement and sealing components before startup in outdoor or washdown process areas. Improper connector sealing may allow moisture intrusion into monitoring circuits.\u003c\/p\u003e\n\u003cp\u003eFor turbine and compressor installations, secure the cable using vibration-resistant clamps to prevent connector loosening during long-term machine operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668310585707,"sku":"CB2W100-32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cb2w100-32-1n0g3cvnptc_00d564cc-d6fe-4cb2-9979-b9f237130c7a.jpg?v=1765520839"},{"product_id":"bently-nevada-89477-20-interconnect-cable-20-ft-industrial-signal-link","title":"Bently Nevada 89477-20 Interconnect Cable 20 ft Industrial Signal Link","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 89477-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an interconnect cable designed for vibration monitoring and machinery protection systems where stable signal transmission between field devices and monitoring modules is required. It is commonly used in turbines, compressors, pumps, and industrial rotating equipment across power generation and process industries.\u003c\/p\u003e\n\u003cp\u003eThis cable provides a direct electrical link between system components, ensuring reliable data transfer in environments with vibration, electrical noise, and continuous industrial operation. It supports consistent signal integrity for condition monitoring systems where measurement accuracy directly affects machine protection decisions.\u003c\/p\u003e\n\u003cp\u003eThe 20 ft length configuration supports flexible installation in control cabinets and field-mounted monitoring setups.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e89477\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20 ft cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis simplified configuration defines cable family type and physical length for system integration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e89477-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e20 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSignal transmission for monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Role\u003c\/td\u003e\n\u003ctd\u003eInterconnect between monitoring and field devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eIndustrial machinery monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is designed for stable low-noise signal transmission in industrial environments where electromagnetic interference and mechanical vibration are present.\u003c\/p\u003e\n\u003cp\u003eIt ensures consistent connectivity between monitoring modules and field instrumentation, supporting accurate vibration and condition monitoring data acquisition.\u003c\/p\u003e\n\u003cp\u003eThe cable structure is optimized for durability under continuous industrial operation conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbine systems, compressors, pumps, and industrial monitoring panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is its main function?\u003c\/strong\u003e\u003cbr\u003eIt provides electrical interconnection between monitoring system components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for industrial vibration and electrical noise conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect performance?\u003c\/strong\u003e\u003cbr\u003eWithin specified design limits, 20 ft supports stable signal transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eRoute cable away from high-voltage power lines to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bends to maintain conductor integrity and signal stability.\u003c\/p\u003e\n\u003cp\u003eEnsure connectors are fully seated to prevent intermittent signal loss.\u003c\/p\u003e\n\u003cp\u003eUse proper cable management to reduce vibration-induced mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper grounding practices to ensure signal stability in noisy environments.\u003c\/p\u003e\n\u003cp\u003eInspect connector interfaces during scheduled maintenance cycles.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical tension on cable ends during installation.\u003c\/p\u003e\n\u003cp\u003eUse standardized routing paths inside control panels to improve reliability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319007083,"sku":"89477-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/89477-20-3chmqkzrnkk_aeabdb4b-577f-4515-af7c-d9847d23c650.jpg?v=1765521126"},{"product_id":"bently-nevada-84661-34-10-meter-velomitor-interconnect-cable","title":"Bently Nevada 84661-34 | 10 meter Velomitor Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 84661-34\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 10 meter Velomitor interconnect cable designed for reliable signal transmission between velocity transducers and vibration monitoring systems. It is used in industrial machinery protection systems across power generation, oil and gas, and process industries where stable vibration signal integrity is critical.\u003c\/p\u003e\n\u003cp\u003eThis cable assembly provides a rugged armored construction to protect signal transmission in high-vibration and harsh environmental conditions. It ensures consistent data transfer from HTVS velocity sensors to monitoring equipment without degradation caused by electrical noise or mechanical stress.\u003c\/p\u003e\n\u003cp\u003eThe stainless steel armor layer enhances mechanical durability, making it suitable for installations exposed to abrasion, moisture, and industrial handling stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConstruction \u0026amp; Design Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Core\u003c\/td\u003e\n\u003ctd\u003eShielded 22 AWG (0.382 mm2) conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eStainless steel protective layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor End\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector (HTVS side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor End\u003c\/td\u003e\n\u003ctd\u003eRing lug termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe structure is engineered to maintain signal integrity while providing mechanical protection in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e84661-34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eArmored interconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Connection\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Connection\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVelocity transducer signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is designed to maintain stable low-noise signal transmission between velocity sensors and monitoring systems in electrically and mechanically harsh environments.\u003c\/p\u003e\n\u003cp\u003eStainless steel armor protects the internal conductors from abrasion and mechanical damage during installation and long-term operation.\u003c\/p\u003e\n\u003cp\u003eShielded conductor design reduces electromagnetic interference, ensuring signal accuracy in environments with variable frequency drives and high-power electrical systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in power plants, refineries, and industrial machinery vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is armored cable important?\u003c\/strong\u003e\u003cbr\u003eIt protects signal integrity against mechanical damage and harsh industrial handling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with all Velomitor sensors?\u003c\/strong\u003e\u003cbr\u003eIt is designed for compatible Bently Nevada Velomitor and HTVS systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it reduce electrical noise?\u003c\/strong\u003e\u003cbr\u003eYes. Shielded construction helps minimize EMI interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid excessive bending during installation to prevent internal conductor stress.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shield layer to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eRoute cable away from high-voltage and VFD power lines for optimal signal integrity.\u003c\/p\u003e\n\u003cp\u003eSecure stainless steel armor properly at mounting points to prevent vibration-induced fatigue.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius to avoid long-term mechanical fatigue in armored structure.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing periodically in moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief at both ends to prevent mechanical load transfer to connectors.\u003c\/p\u003e\n\u003cp\u003eEnsure ring lug termination is firmly secured to monitoring system terminals for stable signal transmission.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319269227,"sku":"84661-34","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/84661-34-xineykv00ar_bd189d67-6de3-412b-8dbc-91f4c1b8515a.jpg?v=1765521137"},{"product_id":"bently-nevada-16925-80-interconnect-cable-without-armor","title":"Bently Nevada 16925-80 Interconnect Cable Without Armor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16925-80\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada interconnect cable designed for signal transmission within industrial vibration monitoring systems where flexible routing is required. It connects system modules, proximity measurement chains, and monitoring interfaces in Bently Nevada architectures used for rotating machinery protection. The cable maintains stable electrical performance in environments with continuous vibration and electrical noise.\u003c\/p\u003e\n\u003cp\u003eThis model is commonly deployed in power plants, oil refineries, compressor stations, and heavy industrial facilities. It supports reliable communication between monitoring components while reducing installation complexity in non-armored routing applications. The absence of armor improves flexibility for cabinet and rack wiring layouts where mechanical protection is already provided by conduit or controlled installation paths.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16925 = Interconnect cable base model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e80 = 80 ft fixed cable length option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWithout armor = flexible standard cable construction without mechanical steel protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable is designed for internal system interconnection where routing flexibility is prioritized over mechanical reinforcement. It maintains stable impedance characteristics suitable for vibration signal transmission in Bently Nevada monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16925-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable Without Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e80 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eNon-armored flexible industrial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring system interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade shielded cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eCabinet and rack wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.131 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the 16925-80 cable typically installed?\u003c\/strong\u003e\u003cbr\u003eIt is used inside control cabinets, racks, and protected industrial wiring paths for monitoring system interconnection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable provide mechanical protection against crushing?\u003c\/strong\u003e\u003cbr\u003eNo. It is non-armored and relies on installation routing or conduit for mechanical protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high vibration environments?\u003c\/strong\u003e\u003cbr\u003eYes, but it must be installed in protected routing paths to avoid mechanical damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with all Bently Nevada systems?\u003c\/strong\u003e\u003cbr\u003eIt is compatible only when system interconnection specifications match the required length and connector configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the cable inside protected conduits or cable trays when used in high vibration industrial environments. Avoid direct exposure to moving machinery or sharp edges.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high voltage power cables and VFD output lines to reduce electromagnetic interference and signal distortion.\u003c\/p\u003e\n\u003cp\u003eUse proper grounding for cable shielding at a single reference point to prevent ground loop noise in vibration monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321825131,"sku":"16925-80","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16925-80-a351m02eaoc_7af58e61-be66-4f3a-bb94-2662eec300f9.jpg?v=1765521172"},{"product_id":"16925-23-bently-nevada-interconnect-cable","title":"16925-23| Bently Nevada | Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16925-23\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada interconnect cable designed for reliable signal transmission between vibration monitoring components in industrial protection systems. It forms part of the signal path used in proximity, velocity, and condition monitoring architectures where stable electrical continuity directly affects measurement accuracy and machine protection response time.\u003c\/p\u003e\n\u003cp\u003eThis cable is widely used in turbine systems, compressors, pumps, and rotating machinery installations across power generation, oil and gas, and heavy industrial plants. It ensures consistent signal integrity between field sensors and monitoring modules, reducing the risk of data loss caused by electromagnetic interference or mechanical stress in harsh environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16925 = Interconnect cable base model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e23 = 23 ft cable length configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable is designed for direct interconnection within Bently Nevada monitoring systems. It maintains controlled electrical characteristics suitable for vibration signal transmission and supports stable operation under continuous industrial vibration and electrical noise conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16925-23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e23 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Function\u003c\/td\u003e\n\u003ctd\u003eSignal interconnection for monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring system wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada condition monitoring platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade shielded construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eIndustrial machinery and control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the 16925-23 cable used in a monitoring system?\u003c\/strong\u003e\u003cbr\u003eIt is used as an interconnect link between vibration monitoring modules and system components in Bently Nevada architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high noise environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed with shielding suitable for industrial electromagnetic interference environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable length fixed at 23 ft?\u003c\/strong\u003e\u003cbr\u003eYes. The “23” suffix defines a fixed 23 ft factory configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable replace other interconnect models?\u003c\/strong\u003e\u003cbr\u003eReplacement is possible only if electrical and length specifications match system requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the cable away from high voltage power lines and VFD output cables to minimize induced electrical noise. Separation improves signal stability in vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003eAvoid tight bending near connectors and junction points. Excess mechanical stress can degrade shielding performance and reduce long-term reliability.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of cable shielding at a single system reference point to prevent ground loop interference in turbine and compressor monitoring environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321857899,"sku":"16925-23","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16925-23-104ffwk3jjl_edf3297d-cdab-4cf7-9cbf-0d5dff551175.jpg?v=1765521173"},{"product_id":"bently-nevada-18622-015-01-interconnect-cable-assembly","title":"Bently Nevada 18622-015-01 Interconnect Cable Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e18622-015-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterconnect cable from Bently Nevada provides reliable signal transmission between vibration monitoring system components in industrial machinery protection applications. It is widely used in power generation plants, oil refineries, petrochemical facilities, and heavy industrial equipment where stable communication between proximity probes, extension systems, and monitoring modules is required for continuous machine condition monitoring.\u003c\/p\u003e\n\u003cp\u003eThis interconnect cable is designed for integration within Bently Nevada monitoring architectures and supports stable electrical signal transfer under high vibration and harsh environmental conditions. The 15 ft (4.572 m) cable length provides flexible installation routing between enclosure systems and field-mounted instrumentation. The armored Teflon cable construction improves resistance to abrasion, chemical exposure, and mechanical stress, making it suitable for demanding industrial environments. The compact design supports clean cable management inside control cabinets and machinery protection systems, helping maintain signal integrity and reducing the risk of unplanned shutdown events caused by wiring degradation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e18622\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable series identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e015\u003c\/td\u003e\n\u003ctd\u003eCable length: 15 ft (4.572 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eArmored Teflon cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e18622-015-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e15 ft (4.572 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored, Teflon insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade signal shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main function of this interconnect cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides stable signal transmission between vibration monitoring components in Bently Nevada machinery protection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is Teflon insulation used in this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTeflon improves resistance to high temperature, chemical exposure, and industrial environmental stress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high vibration environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The armored construction is designed for industrial vibration and mechanical stress conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with all Bently Nevada systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is designed for use within compatible Bently Nevada monitoring and proximity measurement architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from high power conductors and VFD output lines to minimize electromagnetic interference in monitoring signals.\u003c\/p\u003e\n\u003cp\u003eEnsure proper mechanical fixation along cable trays to prevent vibration-induced fatigue at connector points in rotating machinery environments.\u003c\/p\u003e\n\u003cp\u003eAvoid tight bending near termination points to maintain long-term shielding integrity and stable signal performance in industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322644331,"sku":"18622-015-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/18622-015-01-vtm1cdyn4v0_d9fb4d7d-b80f-478a-a0ad-8e330fa758a2.jpg?v=1765521204"},{"product_id":"bently-nevada-16710-65-interconnect-cable-1","title":"Bently Nevada 16710-65 Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65 \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty, 3-conductor shielded interconnect cable designed to maintain signal integrity between proximity transducers and monitoring systems. Engineered for the Bently Nevada 3300 and 3500 Machinery Protection Systems, this cable is essential for transmitting critical vibration, position, and speed data in high-interference industrial environments. Its armored construction provides superior mechanical protection against physical abrasion and crushing forces commonly found in oil refineries, power plants, and heavy manufacturing facilities. By utilizing high-grade 22 AWG wiring and robust shielding, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeffectively eliminates electromagnetic interference (EMI) that can cause false alarms or signal drift. Implementing genuine Bently Nevada cabling is a vital strategy for ensuring the reliability of Turbomachinery Instrumentation (TSI), directly reducing unplanned downtime through stable, high-fidelity data transmission.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a specific Bently Nevada configuration logic for length and termination:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16710:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the base cable assembly type. This includes a 3-conductor, 22 AWG (0.5 mm2) shielded wire housed within flexible stainless steel armor. The assembly features a pre-installed 3-socket plug at the sensor end and terminal lugs at the monitor end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-65:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates the total cable length. In this configuration, the cable is precisely manufactured to a length of 65 feet (approximately 20 meters), allowing for significant distance between the field-mounted junction box and the centralized control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16710-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Conductor Shielded Armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 feet (20 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Socket Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the armored jacket provide environmental sealing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stainless steel armor provides exceptional mechanical protection against impact and abrasion; however, it is not a liquid-tight seal. For applications involving constant immersion or heavy chemical spray, the cable should be routed through additional liquid-tight conduit or housed in sealed trays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be shortened in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the terminal lug end can technically be trimmed, it is not recommended as it destroys the factory-certified termination. Field modifications can introduce impedance mismatches or shielding gaps. It is best practice to order the specific length required for the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the shield connected to the socket plug?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shield is typically isolated at the sensor end plug to prevent ground loops. In a standard Bently Nevada installation, the shield should be grounded only at the monitor rack or the common point in the signal conditioning housing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProper grounding is the most critical factor when installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65\u003c\/strong\u003e. The cable shield must be terminated at the instrument ground in the 3500 rack or the Proximitor housing. Ensure the shield is not inadvertently grounded at the sensor end or at any intermediate junction boxes. \"Floating\" the shield at the sensor end prevents circulating ground currents that can corrupt low-voltage vibration signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius and Mechanical Stress\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDespite the flexible armor, the cable has a minimum bend radius that must be respected to prevent internal conductor fatigue. Avoid sharp 90-degree bends. When securing the cable to machine supports or tray systems, use stainless steel ties or clamps that do not compress the armor, as internal insulation damage can lead to intermittent short circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn Class 1 Div 1 or Zone 0\/1 environments, ensure the armored cable is installed in accordance with local explosion-proof or intrinsically safe wiring standards. The armor provides mechanical protection but does not replace the need for certified cable glands or seals where the cable enters a pressurized or flameproof enclosure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322906475,"sku":"16710-65","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-65-interconnect-cable-y3wsgre5hbc_116b3aaa-6d35-48c4-a8bf-f4c822366c20.jpg?v=1765447167"},{"product_id":"106765-25-bently-nevada-interconnect-cable","title":"106765-25 | Bently Nevada | Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a specialized, ruggedized interconnect cable assembly designed specifically for the Bently Nevada 330525 Velomitor XA (eXtended Application) Piezo-Velocity Sensor series. In critical industrial sectors such as power generation, wastewater treatment, and offshore oil platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the vital link for transmitting high-fidelity vibration data in high-moisture and corrosive environments. By utilizing a unique weatherproof connector system, this cable allows for the direct mounting of sensors without the need for additional protective housings. This streamlined architecture significantly reduces installation complexity while ensuring maximum uptime for rotating assets by maintaining IP-65 and NEMA 4X sealing integrity under the most grueling field conditions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown: 106765-AA\u003c\/h3\u003e\n\u003cp\u003eThe 106765 series uses a modular suffix system to ensure the precise cable reach required for specific machine train geometries:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e106765 Base Model:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDenotes the high-performance interconnect cable assembly designed for Velomitor XA sensors, featuring 316L stainless steel hardware compatibility and weatherproof sealing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAA Option (Length):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDefines the total cable length in meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-25 Suffix:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRepresents a fixed length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25 meters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(approximately 82 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Bently Nevada practice dictates that these specialized cables are typically engineered and ordered in 3-meter increments to maintain electrical impedance consistency across the monitoring loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e106765-25\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Sensors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330525 Velomitor XA Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 meters (82 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP-65 and NEMA 4X (When properly mated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-55 to +121 deg C (-67 to +250 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWeatherproof high-grade synthetic \/ Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Insights \u0026amp; FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 106765-25 compatible with the standard 330500 Velomitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the internal wiring may be similar, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for the \"XA\" (Extended Application) version. The XA series features a unique connector intended for use without a separate housing. Using this cable on a standard 330500 may compromise the environmental seal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the cable handle exposure to chemicals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable jacket and connector materials are selected for high resistance to moisture and industrial contaminants. When coupled with the 316L stainless steel case of the 330525 sensor, the assembly provides superior protection against the corrosive atmospheres common in mining and chemical processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 25-meter length affect signal accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Bently Nevada piezo-velocity systems are designed to drive signals over significant distances. A 25-meter run is well within the operational parameters, provided the cable is routed away from high-voltage interference sources.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing and Moisture Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo achieve the full NEMA 4X and IP-65 rating, the connector must be properly seated and tightened. In outdoor or wash-down areas, engineers should apply a light coating of silicone lubricant to the connector threads (avoiding the pins) to ensure a gas-tight seal and prevent thread galling over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRouting and Mechanical Stress Relief\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGiven the 25-meter span, the cable must be supported in cable trays or conduits. Avoid tight bends that exceed the minimum bend radius (typically 10 times the cable diameter). At the sensor end, provide a small \"drip loop\" to prevent condensed moisture from traveling down the cable and pooling at the connector interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectromagnetic Interference (EMI) Mitigation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEven with ruggedized shielding, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshould be kept at least 0.3 meters (1 foot) away from high-power AC lines and Variable Frequency Drives (VFDs). If the cable must cross a power line, it should do so at a 90-degree angle to minimize the risk of signal noise.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323332459,"sku":"106765-25","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/106765-25-ecuptpeq1ej_127c5dd4-5d11-493b-9515-aa205caa414c.jpg?v=1765521227"},{"product_id":"bently-nevada-interconnect-cable-16710-10","title":"Bently Nevada Interconnect Cable 16710-10","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 16710-10 Interconnect Cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-quality, shielded and armored cable designed for reliable connections in industrial monitoring systems. It ensures secure signal transmission between sensors, relays, and control devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e3-conductor shielded 22 AWG (0.5 mm²) armored cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne end with 3-socket plug; opposite end with terminal lugs for secure connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable length: 3.0 m (-10 option).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 2 solid-state outputs and a relay with 2 NO circuits, volt-free.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight, robust design for industrial environments; shipping weight: 1.5 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16710-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductors\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded 22 AWG (0.5 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Ends\u003c\/td\u003e\n\u003ctd\u003e3-socket plug at one end, terminal lugs at the other\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m (-10 option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuits\u003c\/td\u003e\n\u003ctd\u003eRelay with 2 NO circuits, 2 solid-state outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDesigned for connecting Bently Nevada sensors, relays, and monitoring modules. Ensures reliable signal transmission in vibration and condition monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose This Cable\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-10 Interconnect Cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides robust, shielded, and armored connectivity, ensuring signal integrity and long-term reliability in industrial monitoring setups.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668326314347,"sku":"16710-10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16710-10-rdsihpqwtvz_612c7442-b28f-4a5e-ae73-80aa4061c7e1.jpg?v=1765521328"},{"product_id":"bently-nevada-cb2w100-032-interconnect-cable","title":"Bently Nevada CB2W100-032 Interconnect Cable","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCB2W100-032\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada Interconnect Cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-grade, shielded cable assembly designed for reliable signal transfer between proximity system components. Built for demanding industrial environments, it provides stable electrical performance and secure connections for vibration and condition monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMIL-C-5015 two-socket connector with splash-resistant construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePremium shielded twisted-pair cable, 20 AWG conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTeflon® insulated jacket in high-visibility yellow for durability and chemical resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes locking ring, adapter seal, and O-ring for enhanced environmental protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for applications requiring isolated blunt-cut termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized for Bently Nevada monitoring hardware and transducer systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCB2W100-032\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Standard\u003c\/td\u003e\n\u003ctd\u003eMIL-C-5015, 2-socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eIsolated blunt-cut termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003e20 AWG, twisted pair, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003eTeflon®, yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e32 ft (9.75 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd\u003eLocking ring, adapter seal, O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProximity probe and proximitor sensor interconnections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration monitoring systems in turbines, compressors, and rotating machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal wiring in harsh environments requiring EMI shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement or extension cabling for Bently Nevada systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668326904171,"sku":"CB2W100-032","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cb2w100-032-jehmtr1b1cu_cb2891be-73e2-4d3a-9952-bfce65361c34.jpg?v=1765521352"},{"product_id":"bently-nevada-16710-30-interconnect-cable-30-ft","title":"Bently Nevada 16710-30 Interconnect Cable – 30 ft","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable from Bently Nevada is a high-quality 3-conductor shielded cable designed for reliable signal transmission in industrial machinery monitoring systems. Featuring an armored construction with a 3-socket plug at one end and terminal lugs at the other, this cable ensures secure connections for proximity probes, accelerometers, and vibration sensors. With a length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30 ft (9.0 m)\u003c\/strong\u003e, it is ideal for medium-range installations where durability and signal integrity are critical.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3-conductor shielded 22 AWG (0.5 mm²)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable for precise signal transmission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmored design for enhanced protection in harsh industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3-socket plug\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat one end and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eterminal lugs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat the other for reliable connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible length: minimum\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 ft (0.9 m)\u003c\/strong\u003e, maximum\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e99 ft (30 m)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for use with Bently Nevada vibration monitoring and machinery protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight and durable for easy installation and long-term use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-30 Interconnect Cable\u003c\/strong\u003e\u003cspan\u003eis ideal for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting proximity probes, accelerometers, and other monitoring devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial machinery monitoring in power generation, oil \u0026amp; gas, and manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications requiring reliable armored cables with secure terminations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupporting condition-based maintenance and predictive diagnostics programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16710-30\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded 22 AWG (0.5 mm²), armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConne\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3-socket plug at one end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminations\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs at the other end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3 ft (0.9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Length\u003c\/td\u003e\n\u003ctd\u003e99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Option\u003c\/td\u003e\n\u003ctd\u003e30 ft (9.0 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668327035243,"sku":"16710-30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16710-30-j2lbze14wdj_064c47fd-d0bd-4dd4-b363-2e5a9d044156.jpg?v=1765521361"},{"product_id":"bently-nevada-16925-15-interconnect-cable-without-armor-15-ft","title":"Bently Nevada 16925-15 Interconnect Cable without Armor – 15 ft","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 16925-15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable without Armor is designed to provide reliable signal connections in industrial machinery monitoring systems. With a length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e15 feet\u003c\/strong\u003e, it allows flexible installation in tight or standard layouts. Manufactured in the U.S.A., this cable ensures consistent signal integrity and dependable performance for vibration and condition monitoring applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e15 ft (4.57 m) length\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuitable for short- to medium-range installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-armored design for applications where mechanical protection is not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures stable signal transmission between sensors and monitoring equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight and flexible, simplifying routing and installation in industrial setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for connecting Bently Nevada machinery monitoring devices, including proximity probes and vibration sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLinking proximity probes, accelerometers, and vibration sensors to monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse in industrial environments where physical protection of the cable is not critical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery monitoring setups in manufacturing, energy, and process industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort- and medium-range installations requiring reliable, low-cost cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16925-15\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable without Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e15 ft (4.57 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Manufacture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0.131 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668327100779,"sku":"16925-15","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16925-15-beotmfxrifs_252a18b0-dd75-4def-b339-88b90fe2a372.jpg?v=1765521364"},{"product_id":"bently-nevada-16710-32-interconnect-cable-with-armor-32-ft","title":"Bently Nevada 16710-32 Interconnect Cable with Armor – 32 ft","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOvervi\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable with Armor from Bently Nevada is a high-durability cable designed to provide secure and reliable connections in industrial machinery monitoring systems. With a protective armored coating, this cable is ideal for environments where mechanical protection and resistance to external stress are critical. Its 32-foot length offers flexibility for various installation requirements while maintaining signal integrity and protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32 ft\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(9.75 meters) length provides ample reach for industrial installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmored jacket ensures superior protection against abrasion, physical damage, and environmental hazards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for use with Bently Nevada machinery monitoring systems, including proximity probes and vibration sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust construction ideal for harsh industrial environments such as oil and gas, chemical plants, and manufacturing facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure and stable signal transmission even in the most challenging conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis is not\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting proximity probes and vibration sensors to monitoring systems in industrial machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse in manufacturing plants, oil and gas, and power generation facilities requiring robust signal transmission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAny application requiring cable protection against mechanical stress and harsh conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16710-32\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProd\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable with Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e32 ft (9.75 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Type\u003c\/td\u003e\n\u003ctd\u003eArmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668327362923,"sku":"16710-32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16710-32-ddykalvef3s_f3b80414-b43d-4169-81ac-ba2b611d9683.jpg?v=1765521373"}],"url":"https:\/\/www.plcprotech.com\/collections\/bently-nevada-7200-3300-interconnect-cables.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}