{"title":"Bently Nevada 9200 \u0026 74712 Two-wire Transducer","description":"\u003cp\u003eThe Bently Nevada 9200 and 74712 Two-wire Transducers are seismic velocity sensors designed for continuous vibration monitoring on machine housings. The architecture utilizes a moving-coil design that eliminates the need for external power, producing a voltage proportional to the vibration velocity. Technical characteristics include a wide operating temperature range and a rugged design capable of withstanding high-impact industrial environments. Functionally, these transducers are specialized for monitoring low-to-mid frequency vibrations on large motors, pumps, and fans. They are often integrated with the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-system-monitoring\"\u003e3300 system monitoring\u003c\/a\u003e racks or connected via \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-vibration-transmitters\"\u003evibration transmitters\u003c\/a\u003e to provide a simplified, reliable seismic measurement solution where non-contact proximity probes are not technically feasible.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-9200-06-02-10-00-two-wire-transducer","title":"Bently Nevada 9200-06-02-10-00 Two-Wire Transducer","description":"\u003cp\u003eThe \u003cstrong\u003e9200\u003c\/strong\u003e standard velocity transducer, complete part number \u003cstrong\u003e9200-06-02-10-00\u003c\/strong\u003e, is a two-wire moving-coil transducer designed to measure absolute casing vibration on rotating machinery. The mechanical system features a wire-suspended coil moving around a permanent magnet, providing a voltage output directly proportional to vibration velocity. This self-generating sensor requires no external power and operates within a dedicated orientation window defined by its specific option configuration. The 9200 series utilizes rotor dynamics principles to continuously monitor structural casing movement, ensuring critical machinery protection and interfacing directly with Bently Nevada monitoring systems through low-impedance signal transmission.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-06: Transducer Mounting Angle \/ Minimum Operating Frequency\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e0 ±100° (horizontal placement orientation), 10 Hz (600 cpm) minimum operating frequency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02: Connector Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHermetically sealed side-mount 2-pin connector interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10: Mounting Base Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCircular base geometry featuring an M10X1 threaded stud connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Agency Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo standard hazardous area approvals or certificates required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-02-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Moving-Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100° (Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Operating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSide Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Base Geometry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircular with M10X1 Threaded Stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase and Adapter Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the sensor installation angle precisely matches the 0 ±100° horizontal range specification to avoid physical internal coil binding against the magnet housing.\u003c\/li\u003e\n\u003cli\u003eOperating the transducer below the specified 10 Hz frequency limit causes significant amplitude attenuation and phase shift errors in velocity data.\u003c\/li\u003e\n\u003cli\u003eCross-axis vibration sensitivity must be minimized by aligning the primary measurement axis directly parallel to the intended machinery vibration direction.\u003c\/li\u003e\n\u003cli\u003eThe self-generating coil assembly introduces a fixed internal impedance that must be matched with compatible monitoring instrumentation inputs to prevent signal loading effects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplement dedicated shield grounding protocols by connecting the cable shield at the monitoring rack end only, ensuring the transducer end remains isolated to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing segregation by separating transducer signal lines from high-voltage AC power distribution conduits to reduce electro-magnetic interference.\u003c\/li\u003e\n\u003cli\u003eAvoid exceeding the minimum bending radius of the field wiring cable to prevent internal conductor damage or degradation of the insulation barrier.\u003c\/li\u003e\n\u003cli\u003eVerify the structural integrity of the M10X1 mounting surface, ensuring it is flat, smooth, and free of paint or debris to guarantee accurate high-frequency vibration transmission.\u003c\/li\u003e\n\u003cli\u003eApply correct torque specifications when securing the circular mounting base to the machine casing to prevent resonant frequencies from distorting the velocity readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this 9200-06-02-10-00 model be mounted in a purely vertical orientation on a machine casing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the -06 suffix designates a horizontal mounting configuration of 0 ±100 degrees; vertical mounting requires a different option code to calibrate the internal spring-coil alignment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What components are included inside the shipping box for this specific part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The package contains the brand-new original 9200-06-02-10-00 velocity transducer assembly with its integrated side-mount connector and M10X1 circular mounting base stud.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this specific transducer module require a separate external power supply to output the velocity signal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this is a self-generating electro-magnetic moving-coil sensor that produces its own voltage output relative to velocity without requiring external loop power.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666764493163,"sku":"9200-06-02-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-02-10-00-two-wire-transducer-wh1b32koul4_e61ad530-9ea0-4ba5-a008-11769c81ce20.jpg?v=1765447197"},{"product_id":"bently-nevada-9200-06-05-05-00-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-06-05-05-00 Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-06-05-05-00\u003c\/strong\u003e is a two-wire \u003cstrong\u003evelocity transducer\u003c\/strong\u003e designed for continuous monitoring or periodic diagnostics of absolute casing, bearing housing, or structural vibration. Utilizing moving-coil technology, this instrument generates a voltage output directly proportional to the transducer's vibration velocity without requiring external operating power. The unique mechanical architecture of the \u003cstrong\u003e9200-06-05-05-00\u003c\/strong\u003e ensures low sensitivity to impact or impulsive excitation, delivering highly reliable and repeatable dynamic data on critical machinery such as turbines, pumps, and industrial fans.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMoving-coil technology provides a direct voltage output without the need for external power.\u003c\/li\u003e\n\u003cli\u003eLow sensitivity to impact or impulsive excitation compared to solid-state alternatives.\u003c\/li\u003e\n\u003cli\u003eTwo-wire engineering supports both permanent machinery protection and portable field measurements.\u003c\/li\u003e\n\u003cli\u003eDurable anodized aluminum case construction for survival in aggressive industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAbsolute bearing housing and machinery casing vibration measurements.\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbine casing monitoring protocols.\u003c\/li\u003e\n\u003cli\u003ePeriodic data collection using portable test and diagnostic equipment.\u003c\/li\u003e\n\u003cli\u003eStructural vibration analysis on large-scale balance-of-plant equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFactory Configuration Profile\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Mounting Angle\/Minimum Operating Frequency: 0 ±100, 10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Option: Terminal block top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: No base; 1\/2-in 20 UNF-3A stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-05-05-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) ±5% at +22 Celsius (+72 Fahrenheit) with 25 mm\/s (1 in\/s) vibration at 100 Hz into a 10 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1 kHz (60,000 cpm); +0, -3dB typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100 (Vertical, viewed from driver end)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithstands 50 g peak maximum acceleration along non-sensitive axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Leadwire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) between transducer and 3300 or 3500 Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating\/Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 Celsius to +121 Celsius (-20 Fahrenheit to +250 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasket Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide with nickel-plated copper contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Base Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo base; 1\/2-in 20 UNF-3A stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78.54 mm (3.092 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.40 mm (1.63 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Output (Pin A goes positive with respect to Pin B when case velocity is toward connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Alignment:\u003c\/strong\u003e The transducer must be physically mounted within its designated 0 ±100 vertical limits relative to the calibration angle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Rating:\u003c\/strong\u003e Tighten the integrated 1\/2-in 20 UNF-3A mounting thread to exactly 5.6 Nm (50 in-lb) to guarantee optimal frequency transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Path:\u003c\/strong\u003e Ensure the chosen structural interface point faithfully transmits internal rotor malfunctions to the external casing where the transducer sits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e Verify that the top terminal block connector is fully buttoned up and sealed against regional dust and moisture entry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 05 mounting base configuration indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -05 code indicates that the transducer is supplied with no separate circular or rectangular flange base; instead, it features an integrated 1\/2-in 20 UNF-3A threaded stud directly on the bottom for mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum operating frequency limits of this velocity sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model incorporates the -06 frequency option, establishing a low-end frequency limit of 10 Hz (600 cpm) before signal attenuation starts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the moving-coil principle benefit this transducer over standard accelerometers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause it utilizes moving-coil technology rather than solid-state integration crystals, it is substantially more resilient and less sensitive to mechanical impacts or abrupt impulsive shocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an external power supply or charge amplifier required for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this two-wire velocity system is entirely self-generating and creates a direct voltage output signal from the internal coil movement, making it highly versatile for portable and diagnostic tasks.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666853720427,"sku":"9200-06-05-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-05-05-00-velocity-seismoprobe-w514jt2zgqz_3f2acb0a-f4fb-455f-8d51-77fd859d0a50.jpg?v=1765449119"},{"product_id":"bently-nevada-9200-03-05-10-00-9200-series-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-03-05-10-00 9200 Series Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e9200-03-05-10-00\u003c\/strong\u003e is a 2-wire moving-coil velocity transducer engineered for the absolute vibration measurement of casing structures, bearing housings, or structural components. Operating on a self-generating electrodynamic principle, this \u003cstrong\u003e9200-03-05-10-00\u003c\/strong\u003e seismoprobe transforms mechanical velocity into a proportional voltage signal without requiring external excitation power. Its moving-coil design delivers robust resistance against false trips or signal degradation typically induced by impact, shock, or impulsive excitation near reciprocating or heavy rotating equipment. The transducer features a top-mounted terminal block interface for field electrical termination and mounts onto flat machine surfaces via a threaded stud, allowing direct integration into machinery protection systems, distributed control systems (DCS), or plant asset management monitors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrodynamic moving-coil architecture providing high immunity to false trips caused by shock or high-frequency impact.\u003c\/li\u003e\n\u003cli\u003ePassive, self-generating design eliminates the need for external loop or module power supplies.\u003c\/li\u003e\n\u003cli\u003e2-wire electrical connectivity for straightforward field wiring and long-distance signal transmission.\u003c\/li\u003e\n\u003cli\u003eTop-mounted terminal block layout facilitates flexible configuration of regional field cables.\u003c\/li\u003e\n\u003cli\u003eRugged construction designed to maintain measurement fidelity under continuous machinery case vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHorizontal vibration monitoring on large industrial pumps and fans.\u003c\/li\u003e\n\u003cli\u003eBearing housing casing velocity measurements on steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eStructural monitoring of gearbox casings and support frames.\u003c\/li\u003e\n\u003cli\u003eCasing vibration tracking on industrial motors, generators, and blowers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series: 9200 Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Angle Option: Horizontal (90 degrees +-2.5 degrees), 4.5 Hz minimum operating frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Option: Top-mount terminal block electrical connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: M10x1 threaded mounting stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprovals Option: No hazardous area certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-03-05-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoving-Coil Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive electrodynamic (self-generating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) +-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 1,000 Hz (+0 dB, -3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 degC to +121 degC (-20 degF to +250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal (90 degrees +-2.5 degrees)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm (4 in) typical (depending on connector option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 mm (1.6 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Mounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.41 Nm (12.5 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Block Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Signal Output (Velocity Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Signal Output (Signal Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Preparation:\u003c\/strong\u003e Prepare a flat, clean, and smooth surface on the machine bearing housing or casing. Ensure the area is free of rust, paint, or grease to guarantee proper mechanical transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Threading:\u003c\/strong\u003e Secure the transducer tightly to the prepared surface utilizing the M10x1 threaded mounting stud. Tighten the base mounting stud to a torque specification of 5.6 Nm (50 in lb). Adhere strictly to this limit to prevent casing distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Verification:\u003c\/strong\u003e Align the transmitter strictly for horizontal operation (90 degrees +-2.5 degrees from vertical). Misalignment outside this window alters internal suspension physics and leads to severe measurement errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e When attaching field wiring components, tighten the connector terminals to a specification of 1.41 Nm (12.5 in lb) to establish secure electrical contact without damaging the hardware threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Selection:\u003c\/strong\u003e Use a high-quality, twisted 2-conductor shielded instrument cable to run signals from the top terminal block to the instrumentation rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect the cable shield wire cleanly to the instrumentation or monitor ground at the control room end only. Insulate the shield wire at the transducer terminal box to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpact Prevention:\u003c\/strong\u003e Avoid hitting or dropping the transducer housing during installation procedures to safeguard the internal moving-coil mechanism from structural deformation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864140651,"sku":"9200-03-05-10-00 Transducer","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-03-05-10-00-transducer-ijg1gb5zujl_0d2232c9-47af-4f9b-9832-a31333d0d0bf.jpg?v=1765449391"},{"product_id":"bently-nevada-9200-01-02-10-00-seismoprobe-transducer","title":"Bently Nevada 9200-01-02-10-00 Seismoprobe Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-01-02-10-00\u003c\/strong\u003e is a two-wire \u003cstrong\u003eSeismoprobe Velocity Transducer\u003c\/strong\u003e designed to measure absolute casing vibration on rotating machinery. This moving-coil transducer provides a voltage output directly proportional to the vibration velocity of the machine housing. It operates without external power, utilizing a self-generating design that simplifies field wiring and integration into continuous monitoring systems. The \u003cstrong\u003e9200-01-02-10-00\u003c\/strong\u003e is typically connected to machinery protection systems, such as the Bently Nevada 3500 series, to provide continuous machinery diagnostics, early fault detection, and structural vibration evaluation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelf-generating, moving-coil design requires no external power source.\u003c\/li\u003e\n\u003cli\u003eTwo-wire connection configuration minimizes wiring complexity.\u003c\/li\u003e\n\u003cli\u003eHigh sensitivity to low-frequency machinery casing vibration.\u003c\/li\u003e\n\u003cli\u003eDurable construction suitable for harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003eContinuous online monitoring capabilities for structural and casing velocity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge rotating machinery casing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial fans, blowers, and air handling units\u003c\/li\u003e\n\u003cli\u003eCentrifugal pumps and compressors\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbine housing diagnostics\u003c\/li\u003e\n\u003cli\u003eElectric motor and gearbox structural analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e9200: Two-wire Seismoprobe Velocity Transducer\u003c\/li\u003e\n\u003cli\u003e01: Standard Temperature Version\u003c\/li\u003e\n\u003cli\u003e02: Transducer Mount Option\u003c\/li\u003e\n\u003cli\u003e10: Minimum operating frequency option\u003c\/li\u003e\n\u003cli\u003e00: No Hazardous Area Approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSeismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSensitivity\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e20 mV\/mm\/s (500 mV\/in\/s) plus or minus 5 percent at 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e10 Hz to 1000 Hz plus or minus 3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-29 to +121 Celsius (-20 to +250 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eVertical or horizontal based on option selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eCase Material\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eIntegral cable or top connector variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eEstimated Weight\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eApproximately 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eApprox. 41 mm diameter by 102 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003ePin A \/ Red Wire\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePositive (+) Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003ePin B \/ White Wire\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eNegative (-) Signal \/ Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eShield\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eCase Ground \/ Shield Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Alignment:\u003c\/strong\u003e Ensure the transducer is mounted exactly within its specified orientation limits (vertical or horizontal) to maintain specified accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Preparation:\u003c\/strong\u003e The mounting surface must be flat, smooth, clean, and torque to the recommended engineering specification to ensure proper frequency transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate the cable shield at the monitoring system chassis ground only. Do not connect the shield at the transducer end to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route transducer cables through dedicated conduit or cable trays away from high-voltage lines and heavy electrical machinery to reduce EMI\/RFI noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection:\u003c\/strong\u003e Apply proper environmental sealing or weatherproofing boots to the connector assembly when operating in high humidity or outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core operating principle of the transducer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt utilizes a moving-coil and permanent magnet assembly that generates a voltage output directly proportional to the velocity of the physical vibration without external electrical power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model require an external proximity probe driver or transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it is a self-generating velocity sensor that interfaces directly with the processing monitor card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a vertical transducer is mounted horizontally?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal spring-mass assembly will misalign, causing internal friction, inaccurate readings, and potential damage to the internal coil suspension.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the cable shield be terminated for field installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shield must be insulated at the transducer housing and connected cleanly to the instrument ground inside the monitoring cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be repaired in the field if the housing is damaged?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the transducer is a factory-sealed unit and must be replaced or returned to the manufacturer for recalibration and service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical output impedance of this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt features a low output impedance design making it suitable for driving long transmission cables without significant signal degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs calibration required during initial installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is factory-calibrated and does not require field adjustment, though periodic verification of the sensitivity parameter is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes signal distortion or clipping in this type of sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSevere mechanical shocks exceeding the physical limits of the internal mass suspension can cause internal bottoming and signal distortion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the transducer be painted during routine machinery maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePainting the sensor body is not recommended as it can trap heat, obscure identification labels, and potentially foul the mounting base coupling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does ambient temperature affect the sensitivity of the unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensitivity remains highly stable across the specified operating temperature range, with minor variance accounted for in the engineering verification data.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866794859,"sku":"9200-01-02-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-01-02-10-00-seismoprobe-transducer-akmea2itopi_2a477c9a-18b7-4ceb-998c-500cda761ba9.jpg?v=1765449481"},{"product_id":"bently-nevada-9200-06-05-10-00-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-06-05-10-00 Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-06-05-10-00\u003c\/strong\u003e is a two-wire \u003cstrong\u003evelocity transducer\u003c\/strong\u003e engineered for continuous monitoring or periodic measurements of absolute structural, casing, or bearing housing vibration. Operating via moving-coil technology, this system delivers a voltage output directly proportional to the mechanical vibration velocity without requiring an external power source. The \u003cstrong\u003e9200-06-05-10-00\u003c\/strong\u003e configuration is specifically less sensitive to impact or impulsive excitation compared to solid-state sensors, making it ideal for standard casing velocity applications across critical machinery like turbines, fans, and pumps.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire moving-coil technology design providing an direct voltage output without external power\u003c\/li\u003e\n\u003cli\u003eReduced sensitivity to impact or impulsive excitation compared to solid-state alternatives\u003c\/li\u003e\n\u003cli\u003eSuitable for both continuous machinery protection and periodic portable diagnostics\u003c\/li\u003e\n\u003cli\u003eHigh-grade anodized aluminum casing providing robust resistance to industrial environmental factors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAbsolute bearing housing and casing vibration measurement on rotating machinery\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbine structural vibration monitoring\u003c\/li\u003e\n\u003cli\u003ePortable test instrument data collection and diagnostics\u003c\/li\u003e\n\u003cli\u003eBalance and misalignment tracking on heavy industrial fans and pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFactory Configuration Profile\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Mounting Angle\/Minimum Operating Frequency: 0 ±100, 10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Option: Terminal block top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: Circular; M10X1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-05-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) ±5% at +22 Celsius with 25 mm\/s of casing vibration at 100 Hz under 10 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom 10 Hz to 1 kHz (60,000 cpm); +0, -3dB typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100 (Vertical, viewed from driver end)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithstands 50 g peak maximum acceleration along non-sensitive axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Leadwire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) between transducer and 3300\/3500 Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 Celsius to +121 Celsius (-20 Fahrenheit to +250 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasket Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block top mount (Polyphenylene Sulfide with nickel-plated copper contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircular; M10X1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78.54 mm (3.092 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.40 mm (1.63 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Signal Out (Signal goes positive with respect to B when case velocity moves toward connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Signal Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Alignments:\u003c\/strong\u003e Ensure the transducer is installed strictly within its specified 0 ±100 vertical boundaries relative to the machine axis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Application:\u003c\/strong\u003e Tighten the M10X1 mounting base option to exactly 5.6 Nm (50 in-lb) during seating to preserve optimal amplitude and frequency response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Fidelity:\u003c\/strong\u003e Verify that structural or rotor vibration paths are faithfully transmitted to the bearing housing or casing location chosen for the transducer installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Countermeasures:\u003c\/strong\u003e Ensure the top-mounted terminal block enclosure is sufficiently protected against dust and moisture ingestion to fit local environmental ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 9200-06-05-10-00 require an external power supply to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this transducer leverages a moving-coil architecture which inherently creates its own voltage signal output proportional to the vibration velocity without external power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum operating frequency threshold for this precise configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific unit uses the -06 option, which defines a minimum operating frequency threshold of 10 Hz (600 cpm).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the sensor signal cable be handled over long distances?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system supports up to 305 meters of leadwire between the velocity sensor and a 3300 or 3500 series monitor, though you should consult the manual for high-frequency roll-off parameters when using extended lengths.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary differences between this moving-coil sensor and solid-state alternatives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMoving-coil sensors display much lower sensitivity to impact or impulsive excitations compared to embedded integration solid-state alternatives, providing specific advantages on designated casing installations.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867712363,"sku":"9200-06-05-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-05-10-00-velocity-seismoprobe-jzrvpejc0gv_9b3aa907-a1c6-44fd-96f1-814ed8ac1a38.jpg?v=1765449515"},{"product_id":"bently-nevada-9200-01-02-02-00-two-wire-transducer","title":"Bently Nevada  9200-01-02-02-00 Two-wire Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 9200-01-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a two-wire vibration transducer designed for continuous measurement of machinery vibration in pumps, fans, compressors, and general-purpose industrial rotating equipment. It provides a compact and cost-effective monitoring solution for condition-based maintenance systems where full proximity probe architecture is not required.\u003c\/p\u003e\n\u003cp\u003eThis transducer is widely used in auxiliary machinery protection systems across power plants, water treatment facilities, and process industries. It converts mechanical vibration into a proportional electrical signal suitable for direct connection to monitoring and control systems.\u003c\/p\u003e\n\u003cp\u003eThe side-mount connector and circular 1\/4 in 28 UNF stud base support flexible installation on standard machine housings, ensuring stable mechanical coupling and consistent vibration transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9200\u003c\/td\u003e\n\u003ctd\u003eTwo-wire vibration transducer series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eMounting angle and minimum operating frequency option (0 ±2.5, 4.5 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eSide-mount connector configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eCircular base with 1\/4 in 28 UNF stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines mechanical orientation, connector position, and mounting interface within the 9200 series transducer architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9200-01-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-wire vibration transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eSide mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base\u003c\/td\u003e\n\u003ctd\u003eCircular, 1\/4 in 28 UNF stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz minimum (270 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Angle\u003c\/td\u003e\n\u003ctd\u003e0 ±2.5 configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003eTwo-wire loop powered system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe two-wire design simplifies installation by combining power supply and signal transmission in a single loop configuration. This reduces wiring complexity in distributed monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe circular stud mounting base ensures stable mechanical coupling to machine surfaces, which is critical for accurate vibration transmission.\u003c\/p\u003e\n\u003cp\u003eLow-frequency response capability allows monitoring of slow-speed machinery where traditional high-frequency sensors may not provide sufficient sensitivity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this transducer typically used?\u003c\/strong\u003e\u003cbr\u003eIt is used in general industrial machinery such as pumps, fans, and auxiliary compressors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for high-speed turbine monitoring?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed for general-purpose machinery, not high-precision turbine proximity measurement systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of two-wire design?\u003c\/strong\u003e\u003cbr\u003eIt reduces wiring complexity by combining signal and power in a single loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used in legacy monitoring systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly used in retrofit and general-purpose condition monitoring applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure solid mechanical mounting using the 1\/4 in 28 UNF stud to guarantee accurate vibration transmission from machine surface to sensor body.\u003c\/p\u003e\n\u003cp\u003eAvoid loose mounting conditions, as poor mechanical coupling directly affects signal accuracy.\u003c\/p\u003e\n\u003cp\u003eRoute transducer wiring away from high-voltage and motor drive cables to minimize electrical noise interference.\u003c\/p\u003e\n\u003cp\u003eVerify correct loop power configuration before commissioning to ensure stable signal output.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper surface preparation before installation to ensure flat and stable mounting contact.\u003c\/p\u003e\n\u003cp\u003eUse torque-controlled tightening for stud mounting to prevent mechanical stress damage to the housing.\u003c\/p\u003e\n\u003cp\u003eAvoid installing in areas with excessive structural resonance that may distort vibration readings.\u003c\/p\u003e\n\u003cp\u003ePeriodically inspect mounting integrity in high-vibration environments to ensure long-term measurement stability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321268075,"sku":"9200-01-02-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-01-02-02-00-lyutop23y3j_d66bbd30-1837-4d70-a2d9-9f4778f18244.jpg?v=1765521151"},{"product_id":"bently-nevada-9200-03-24-10-00-two-wire-velocity-seismoprobe-transducer","title":"Bently Nevada 9200-03-24-10-00 Two-wire Velocity Seismoprobe Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9200-03-24-10-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etwo-wire velocity Seismoprobe transducer from Bently Nevada is designed for continuous vibration monitoring of industrial rotating and reciprocating machinery. It is widely used in power generation plants, oil and gas facilities, compressors, pumps, and heavy industrial systems where accurate vibration measurement is required to ensure machine reliability and reduce unplanned downtime.\u003c\/p\u003e\n\u003cp\u003eThis velocity transducer operates on a two-wire configuration, simplifying field wiring while maintaining stable signal transmission for condition monitoring systems. The mounting configuration supports a circular M10x1 stud, providing secure mechanical installation in industrial environments with high vibration levels. The 90 degree ±2.5 mounting angle option and 4.5 Hz minimum operating frequency ensure stable low-frequency response for slow-speed machinery applications. The environmentally resistant integral cable connector allows direct installation in exposed environments. With a compact body design and rugged construction, the device maintains consistent performance under harsh operational and thermal conditions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eMounting angle 90 degree ±2.5, minimum operating frequency 4.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003eEnvironmentally resistant connector with integral cable (custom length 2.1 m to 15 m range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eCircular mounting base with M10x1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9200-03-24-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eCircular base M10x1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Angle\u003c\/td\u003e\n\u003ctd\u003e90 deg ±2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Frequency\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eIntegral cable, environmentally resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Range\u003c\/td\u003e\n\u003ctd\u003e2.1 m to 15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e102 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e41 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eVelocity vibration sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of a two-wire velocity transducer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt simplifies installation by reducing wiring complexity while maintaining reliable vibration signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transducer be used in low-speed machinery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports a low-frequency response down to 4.5 Hz, suitable for slow-speed equipment monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable length adjustable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The integral cable option supports lengths from 2.1 m up to 15 m depending on installation requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this suitable for outdoor industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The environmentally resistant connector and rugged housing support harsh field conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eEnsure the mounting stud is tightened according to manufacturer torque specifications to maintain accurate vibration coupling.\u003c\/p\u003e\n\u003cp\u003eRoute signal cables away from high voltage and VFD lines to reduce electromagnetic interference in vibration measurement systems.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable strain relief to prevent connector fatigue in high vibration installations.\u003c\/p\u003e\n\u003cp\u003eAvoid installing near high thermal radiation sources to preserve sensor stability and long-term accuracy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322349419,"sku":"9200-03-24-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-03-24-10-00-kul4bizo52s_0af56f41-8cb1-467a-aa7e-5c3c3e17f1b5.jpg?v=1765521195"},{"product_id":"bently-nevada-74712-06-05-03-00-74712-high-temperature-two-wire-transducer","title":"Bently Nevada 74712-06-05-03-00 | 74712 High-Temperature Two-Wire Transducer","description":"\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-03-00\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a heavy-duty, high-temperature two-wire seismic vibration transducer engineered for aggressive machinery protection systems. This specialized sensor is primarily deployed in gas and steam turbine power plants, petrochemical refineries, and heavy steel mills where standard vibration probes fail due to excessive ambient heat. By generating a continuous, proportional velocity signal from critical rotating machinery castings and bearing housings, it provides instant diagnostic visibility. Installing this highly stable seismic sensor ensures real-time detection of structural imbalance, mechanical looseness, and bearing degradation. This predictive monitoring directly mitigates catastrophic failures, extends operational runtimes, and prevents costly unplanned downtime in critical high-heat processes.\u003c\/p\u003e\n\u003ch3\u003eCode Allocation \u0026amp; Suffix Decoupling\u003c\/h3\u003e\n\u003cp\u003eThe specialized model number structure of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseismic transducer translates to the following factory mechanical configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e74712\u003c\/strong\u003e: Base model designation for the Bently Nevada High-Temperature Two-Wire Seismic Transducer series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: Transducer Mounting Angle\/Minimum Operating Frequency Option specifying a 0 plus\/minus 100 degrees mounting orientation with a 10 Hz (600 cpm) minimum operating frequency threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Mounting Base Option designating no integrated base, utilizing a standard 1\/2-in 20 UNF-3A mounting stud.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Connector Option featuring a ruggedized, top-mounted integrated terminal block for simplified field wire connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval Option denoting a standard, non-certified build for non-hazardous industrial areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertified Mechanical \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Metric Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e74712-06-05-03-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeismic Velocity (Two-wire loop powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Angle Orientation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 plus\/minus 100 degrees vertical alignment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Operating Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz (600 cpm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-in 20 UNF-3A stud (no base)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTermination Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTop-mount terminal block connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTypical Housing Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e41 mm (1.6 in) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Core Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.48 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGross Shipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (including rugged shock-absorbent packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Diagnostics \u0026amp; Integration FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary operational advantage of the 10 Hz (600 cpm) low-frequency limit specified by Option 06?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 10 Hz low-frequency limit enables the sensor to accurately monitor low-speed structural vibrations and bearing casing movements common in heavy industrial machinery, filtering out slow-frequency thermal expansion while preserving high-frequency rotational data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the top-mounted terminal block option simplify installation compared to integrated cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"03\" top-mount terminal block design allows field technicians to terminate existing industrial field cabling directly onto the sensor body. This eliminates the need for expensive molded proprietary connectors and simplifies cable replacements in tight, high-temperature conduits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this transducer be mounted in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \"06\" option limits the functional orientation to 0 plus\/minus 100 degrees (typically vertical or near-vertical). Mounting this transducer outside of this specified angular tolerance will cause the internal seismic mass to drift off-center, leading to inaccurate readings and physical internal wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Manual\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Mechanical Coupling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the mounting surface of the machine housing is flat, clean, and free of paint or rust before mounting. Thread the 1\/2-in 20 UNF-3A mounting stud into the machine casing. Apply a thin layer of silicone grease to the mating surfaces and tighten the transducer to the recommended installation torque to ensure perfect acoustic coupling for dynamic vibration transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Temperature Cable Strain Relief:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen wiring the top-mounted terminal block in extreme temperature zones, use high-temperature rated, shielded twisted-pair cabling. Provide a generous cable loop (strain relief) immediately exiting the terminal block to prevent high-amplitude mechanical vibration from putting physical stress on the wire termination screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Ground Loop Prevention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the cable shield wire to the instrument common ground at the monitor or DCS end only. Do not ground the cable shield at the transducer terminal block or machine casing. This single-point grounding layout prevents ground loops and blocks electromagnetic interference (EMI) from adjacent high-power motor drivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323561835,"sku":"74712-06-05-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-06-05-03-00-5nhmfoh3mdd_5c3f81cf-6735-4129-b6ef-4b0b7c8cff34.jpg?v=1765521236"},{"product_id":"74712-06-05-04-00-bently-nevada-high-temperature-two-wire-transducer","title":"74712-06-05-04-00 Bently Nevada High-Temperature Two-Wire Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty, high-temperature seismic velocity transducer engineered by Bently Nevada for the most demanding industrial environments. Specifically designed to monitor vibration on gas turbines, steam turbines, and other rotating machinery where surface temperatures exceed the limits of standard sensors, this two-wire transducer provides a self-generated electrical signal proportional to vibration velocity. Its robust construction ensures reliable performance in the high-heat zones of power generation and petrochemical facilities, allowing for continuous monitoring of critical assets to prevent costly mechanical failure and extend the Mean Time Between Failures (MTBF).\u003c\/p\u003e\n\u003ch3\u003eSuffix Logic Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe specific hardware configuration for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by the following industrial options:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e74712\u003c\/strong\u003e: Base model for the High-Temperature Two-Wire Velocity Transducer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-90\"\u003e\u003c\/span\u003e\u003cstrong\u003e06 (Mounting Angle\/Freq Option)\u003c\/strong\u003e\u003cspan class=\"citation-90 citation-end-90\"\u003e: Optimized for a mounting angle of 0 plus or minus 100 degrees, with a minimum operating frequency of 10 Hz (600 cpm).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Mounting Base Option)\u003c\/strong\u003e: Supplied without a base; features a direct 1\/2-in 20 UNF-3A integrated stud for rigid mechanical coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04 (Connector Option)\u003c\/strong\u003e: Configured with a side-mount connector interface, ideal for installations with limited vertical overhead clearance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Agency Approval Option)\u003c\/strong\u003e: Standard non-certified version for general industrial use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e74712-06-05-04-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-Wire Velocity Transducer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin Operating Freq\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz (600 cpm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Angle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 +\/- 100 degrees\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Stud\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-in 20 UNF-3A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSide Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e41 mm (1.6 in) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.48 kg (1.06 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn what specific scenarios is a side-mount connector (Option 04) preferred?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe side-mount configuration is critical for turbine housings or bearing pedestals where the surrounding heat shielding or acoustic enclosures provide insufficient vertical space for a top-exit cable. It also assists in creating a natural \"drip loop\" to prevent moisture from following the cable into the connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transducer require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-89\"\u003eAs a velocity transducer based on moving-coil technology, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan class=\"citation-89 citation-end-89\"\u003e\u003cspan\u003e \u003c\/span\u003eis self-generating.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt converts mechanical vibration directly into a voltage signal, which simplifies field wiring and reduces the risk of electronic component failure in high-heat zones.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 10 Hz minimum frequency?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis frequency rating ensures the sensor is tuned to capture the fundamental rotational speeds and primary harmonics of large-scale turbines (600 rpm and above). It is not recommended for very slow-speed machinery where frequencies drop below 10 Hz.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Isolation and Cable Selection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis rated for high temperatures, the longevity of the installation depends heavily on the cabling. Always use high-temperature TFE-insulated shielded cables. Ensure the side-mount connector is securely tightened and, if necessary, protected by a heat-reflective sleeve to prevent localized \"hot spots\" from degrading the connector seals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Integrity and Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1\/2-in 20 UNF stud (Option 05) provides a massive, rigid connection point necessary for accurate seismic vibration transmission. Ensure the mounting surface is machined flat to a 0.001-inch total indicator reading. Apply appropriate torque to prevent the sensor from loosening under high-vibration conditions, as any \"sensor rattle\" will manifest as high-frequency noise in the vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrientation Awareness\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"06\" option is designed for near-horizontal mounting. Significant deviation from the specified mounting angle (outside the +\/- 100-degree range) can cause the internal moving coil to contact the housing walls, resulting in \"clipped\" signals and inaccurate vibration readings. Always verify the machine surface angle before installation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324053355,"sku":"74712-06-05-04-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-06-05-04-00-g0ib0cc4duz_7b5a4c3a-dec7-4315-957f-3f91417ce102.jpg?v=1765521256"},{"product_id":"bently-nevada-9200-10-01-10-00-two-wire-transducer","title":"Bently Nevada 9200-10-01-10-00 Two-wire Transducer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe 9200-10-01-10-00 is a two-wire transducer designed for continuous vibration and condition monitoring. It supports stable signal transmission using a simple two-wire configuration. Moreover, it is suitable for permanent installation in industrial machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e9200-10-01-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin (COO)\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Configuration\u003c\/td\u003e\n\u003ctd\u003eTwo-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Angle \/ Min Operating Frequency\u003c\/td\u003e\n\u003ctd\u003eOption 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Option\u003c\/td\u003e\n\u003ctd\u003e01 = Top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base Option\u003c\/td\u003e\n\u003ctd\u003e10 = Circular base, M10 × 1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00 = No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Configuration\u003c\/td\u003e\n\u003ctd\u003eStud-mounted transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePermanent installation on rotating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial asset protection applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668329984363,"sku":"9200-10-01-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-10-01-10-00-ow5ndtwc2ed_67e75373-b998-4e38-a061-173aebb38270.jpg?v=1765521408"}],"url":"https:\/\/www.plcprotech.com\/collections\/bently-nevada-9200-74712-two-wire-transducer.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}