{"title":"Bently Nevada Velocity Sensors \u0026 Accelerometers","description":"\u003cp\u003eBently Nevada Velocity Sensors and Accelerometers are engineered to measure casing vibration and high-frequency seismic activity in industrial machinery. The architecture typically involves piezoelectric ceramic elements or moving-coil designs encased in hermetically sealed stainless steel housings. Key technical characteristics include wide frequency response ranges, EMI\/RFI shielding, and various mounting configurations. These sensors are functionally capable of detecting rolling-element bearing failures, gear mesh issues, and structural resonance. Products like the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-9200-74712-two-wire-transducer\"\u003e9200 \u0026amp; 74712 two-wire transducer\u003c\/a\u003e provide critical data for machines where \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-xl-proximity-probe\"\u003eproximity probes\u003c\/a\u003e are not applicable, ensuring comprehensive monitoring of both the rotor and the machine housing for complete mechanical health assessment via \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-vibration-transmitters\"\u003evibration transmitters\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-am3100t2-z2-iepe-accelerometer","title":"Bently Nevada AM3100T2-Z2 IEPE Accelerometer","description":"\u003ch2\u003eAM3100T2-Z2 Description\u003c\/h2\u003e\n\u003cp\u003eThe AM3100T2-Z2 is an Integrated Electronics Piezo-Electric (IEPE) accelerometer optimized for obtaining high quality vibration signals in harsh industrial environments. Its piezo sensing element provides exceptional dynamic range, frequency range, and linearity, while the integrated amplifier boosts the signal and improves immunity to electrical noise.\u003c\/p\u003e\n\u003cp\u003eThe sensor requires an industry standard constant-current power supply and provides an output voltage proportional to the acceleration signal, allowing interface with a wide variety of condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe AM3100T2-Z2 features a top-exit connector configuration, 100 mV\/g sensitivity, and Zone 2 hazardous-area certification.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRugged stainless design, corrosion resistant\u003c\/li\u003e\n\u003cli\u003eHermetic seal, case isolated\u003c\/li\u003e\n\u003cli\u003eESD protection\u003c\/li\u003e\n\u003cli\u003eReverse wiring protection\u003c\/li\u003e\n\u003cli\u003eEMI \/ RFI shielded\u003c\/li\u003e\n\u003cli\u003eHazardous area certifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAble to fit in small spaces\u003c\/li\u003e\n\u003cli\u003eLight weight for walk around programs\u003c\/li\u003e\n\u003cli\u003eCross wiring does not harm sensor\u003c\/li\u003e\n\u003cli\u003ePrevents ground loops in permanent mount applications\u003c\/li\u003e\n\u003cli\u003eCan be hosed down or submersed with proper connector\u003c\/li\u003e\n\u003cli\u003eCan be used in applicable certified hazardous areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eDynamic\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSensitivity, ±5% @25°C\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e100 mV\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eAcceleration range\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e80 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAmplitude nonlinearity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eFrequency response ±10%\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.7-9,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eFrequency response ±3 dB\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0.4-14,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eResonant frequency\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e30 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eTransverse sensitivity, max\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e±5% of axial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eTemperature response\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-55°C : -20% \/ +120°C : +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eVoltage source\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e18-30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eCurrent regulating diode\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e2-10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eBroadband electrical noise @ 2.5 Hz to 25 kHz\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e500 μg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSpectral electrical noise @ 10 Hz\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e7 μg\/√Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSpectral electrical noise @ 100 Hz\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4 μg\/√Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSpectral electrical noise @ 1000 Hz\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e2 μg\/√Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eOutput Impedance, max\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eBias output voltage\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eGrounding\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eCase isolated, internally shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-55°C to 120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eVibration limit\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e500 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eShock limit\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e5,000 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eElectromagnetic sensitivity, equiv g, max\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e70 μg\/gauss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSealing\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eHermetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eBase strain sensitivity, max\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0.0002 g\/μstrain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePhysical\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSensing element design\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePZT ceramic \/ shear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e62 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eCase material\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e316L Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e¼-28 UNF tapped hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eTop exit, 2-pin, MIL-C-5015 style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eRecommended cabling\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eShielded, twisted pair, no longer than 100 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eConnector PinFunction\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eShell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eGround\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eA\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003ePower \/ Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eB\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFrequency response and spectral noise values are typical.\u003c\/p\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003ch3\u003eMounting Surface Preparation\u003c\/h3\u003e\n\u003cp\u003eInstall the sensor on a clean, flat, and rigid mounting surface. Remove paint, rust, grease, and debris before installation to ensure proper mechanical coupling and accurate vibration transmission.\u003c\/p\u003e\n\u003cp\u003ePoor mounting surfaces may reduce high-frequency response and introduce measurement errors.\u003c\/p\u003e\n\u003ch3\u003eMounting Procedure\u003c\/h3\u003e\n\u003cp\u003eUse the supplied ¼-28 mounting stud for installation.\u003c\/p\u003e\n\u003cp\u003eInstallation recommendations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper thread engagement\u003c\/li\u003e\n\u003cli\u003eTighten the sensor securely\u003c\/li\u003e\n\u003cli\u003eAvoid excessive mounting torque\u003c\/li\u003e\n\u003cli\u003ePrevent sensor base distortion during installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Routing\u003c\/h3\u003e\n\u003cp\u003eUse shielded twisted-pair cable as recommended by the manufacturer.\u003c\/p\u003e\n\u003cp\u003eFor best signal quality:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKeep cables away from high-voltage wiring\u003c\/li\u003e\n\u003cli\u003eAvoid routing near VFD output cables and large motors\u003c\/li\u003e\n\u003cli\u003ePrevent sharp cable bends\u003c\/li\u003e\n\u003cli\u003eSecure the cable to reduce movement-induced noise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRecommended cable length should not exceed 100 feet.\u003c\/p\u003e\n\u003ch3\u003eConnector Protection\u003c\/h3\u003e\n\u003cp\u003eThe sensor uses a top-exit 2-pin MIL-C-5015 style connector.\u003c\/p\u003e\n\u003cp\u003eIn wet or outdoor environments:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFully tighten the connector\u003c\/li\u003e\n\u003cli\u003eUse moisture-resistant cables and connectors\u003c\/li\u003e\n\u003cli\u003eRegularly inspect sealing integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe hermetic sensor body helps protect against moisture ingress when properly installed.\u003c\/p\u003e\n\u003ch3\u003ePower Supply Requirements\u003c\/h3\u003e\n\u003cp\u003eThe AM3100T2-Z2 requires an IEPE constant-current power source.\u003c\/p\u003e\n\u003cp\u003eRequired electrical supply:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage source: 18–30 Vdc\u003c\/li\u003e\n\u003cli\u003eCurrent regulating diode: 2–10 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify compatibility with the monitoring system before commissioning.\u003c\/p\u003e\n\u003ch3\u003eGrounding Practices\u003c\/h3\u003e\n\u003cp\u003eThe sensor is case isolated and internally shielded to help reduce ground loop problems.\u003c\/p\u003e\n\u003cp\u003eRecommended practices:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse single-point grounding\u003c\/li\u003e\n\u003cli\u003eAvoid multiple shield grounding locations\u003c\/li\u003e\n\u003cli\u003eInspect grounding continuity during installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHazardous Area Installation\u003c\/h3\u003e\n\u003cp\u003eThe AM3100T2-Z2 is approved for Zone 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003eInstallation must comply with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall per drawing 117M2767\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEnsure all associated wiring, barriers, and cable glands meet hazardous-area installation requirements.\u003c\/p\u003e\n\u003ch2\u003eCompliance and Certifications\u003c\/h2\u003e\n\u003ch3\u003eEuropean Community Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX Directive 2014\/34\/EU\u003c\/li\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eLV Directive 2014\/35\/EU\u003c\/li\u003e\n\u003cli\u003eReach Directive 1907\/2006\/EC\u003c\/li\u003e\n\u003cli\u003eROHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEN 61326-1\u003c\/li\u003e\n\u003cli\u003eEN 60079-0\u003c\/li\u003e\n\u003cli\u003eEN 60079-15\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHazardous Area Approvals\u003c\/h3\u003e\n\u003ch4\u003eCSA\/NRTL\/C\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Div 2, Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 2, AEx\/Ex nA IIC T4\u003c\/li\u003e\n\u003cli\u003eInstall per drawing 117M2767\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eATEX \/ IECEx\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eII 3G Ex nA nC IIC T4 Gc\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat type of sensor is the AM3100T2-Z2?\u003c\/h3\u003e\n\u003cp\u003eThe AM3100T2-Z2 is an IEPE accelerometer designed for industrial vibration monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eWhat is the sensor sensitivity?\u003c\/h3\u003e\n\u003cp\u003eThe sensor sensitivity is 100 mV\/g (±5% at 25°C).\u003c\/p\u003e\n\u003ch3\u003eWhat is the acceleration measurement range?\u003c\/h3\u003e\n\u003cp\u003eThe sensor supports an acceleration range of 80 g peak.\u003c\/p\u003e\n\u003ch3\u003eWhat frequency range does the sensor support?\u003c\/h3\u003e\n\u003cp\u003eFrequency response specifications are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e±10%: 0.7–9,000 Hz\u003c\/li\u003e\n\u003cli\u003e±3 dB: 0.4–14,000 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat power supply is required?\u003c\/h3\u003e\n\u003cp\u003eThe sensor requires:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e18–30 Vdc supply voltage\u003c\/li\u003e\n\u003cli\u003e2–10 mA constant current excitation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIs the sensor suitable for hazardous areas?\u003c\/h3\u003e\n\u003cp\u003eYes. The AM3100T2-Z2 is certified for Zone 2 hazardous-area applications.\u003c\/p\u003e\n\u003ch3\u003eWhat connector type does the sensor use?\u003c\/h3\u003e\n\u003cp\u003eThe device uses a top-exit 2-pin MIL-C-5015 style connector.\u003c\/p\u003e\n\u003ch3\u003eIs the sensor case grounded?\u003c\/h3\u003e\n\u003cp\u003eNo. The sensor is case isolated and internally shielded.\u003c\/p\u003e\n\u003ch3\u003eWhat is the operating temperature range?\u003c\/h3\u003e\n\u003cp\u003eThe operating temperature range is -55°C to 120°C.\u003c\/p\u003e\n\u003ch3\u003eCan the sensor be used in wet environments?\u003c\/h3\u003e\n\u003cp\u003eYes. The sensor has a hermetic seal and can operate in wet environments when proper sealed connectors and cables are used.\u003c\/p\u003e\n\u003ch3\u003eWhat mounting thread does the sensor use?\u003c\/h3\u003e\n\u003cp\u003eThe mounting interface is a ¼-28 UNF tapped hole.\u003c\/p\u003e\n\u003ch3\u003eWhat cable type is recommended?\u003c\/h3\u003e\n\u003cp\u003eShielded twisted-pair cable is recommended, with a maximum length of 100 feet.\u003c\/p\u003e\n\u003ch3\u003eDoes the sensor include reverse wiring protection?\u003c\/h3\u003e\n\u003cp\u003eYes. The device includes reverse wiring protection to help prevent damage caused by incorrect wiring.\u003c\/p\u003e\n\u003ch3\u003eIs the sensor resistant to EMI and RFI?\u003c\/h3\u003e\n\u003ch3\u003eYes. The sensor includes EMI\/RFI shielding to improve electrical noise immunity.\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666532561259,"sku":"AM3100T2-Z2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-am3100t2-z2-accelerometer-sensor-fdikhyz1gl3_fd86dddc-70d0-4bf5-b7f2-586e8d47d783.jpg?v=1765440377"},{"product_id":"bently-nevada-as3100s2-z0-iepe-accelerometer","title":"Bently Nevada AS3100S2-Z0 IEPE Accelerometer","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada AS3100S2-Z0\u003c\/strong\u003e is an Integrated Electronics Piezo-Electric (IEPE) accelerometer designed for vibration monitoring in industrial environments. The sensor provides an output voltage proportional to machine acceleration and interfaces with constant-current powered condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThis accelerometer uses a piezoelectric sensing element with an integrated amplifier to improve signal integrity and reduce susceptibility to electrical noise. The device supports vibration measurement applications requiring wide dynamic range, stable linearity, and extended frequency response characteristics.\u003c\/p\u003e\n\u003cp\u003eThe sensor features a hermetically sealed stainless steel housing with case isolation for reduced ground loop effects in permanently mounted installations. The side-exit connector configuration supports installations where cable routing space is limited.\u003c\/p\u003e\n\u003cp\u003eTypical applications include rotating machinery monitoring, predictive maintenance systems, process plant vibration analysis, compressors, pumps, motors, fans, and general industrial machinery protection systems.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Electronics Piezo-Electric (IEPE) design\u003c\/li\u003e\n\u003cli\u003e100 mV\/g sensitivity\u003c\/li\u003e\n\u003cli\u003eStainless steel housing\u003c\/li\u003e\n\u003cli\u003eHermetic sealing\u003c\/li\u003e\n\u003cli\u003eCase isolated construction\u003c\/li\u003e\n\u003cli\u003eReverse wiring protection\u003c\/li\u003e\n\u003cli\u003eEMI\/RFI shielding\u003c\/li\u003e\n\u003cli\u003eESD protection\u003c\/li\u003e\n\u003cli\u003eSide-exit connector configuration\u003c\/li\u003e\n\u003cli\u003eWide frequency response\u003c\/li\u003e\n\u003cli\u003eCompatible with constant-current power supplies\u003c\/li\u003e\n\u003cli\u003eSuitable for harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine vibration monitoring\u003c\/li\u003e\n\u003cli\u003ePump condition monitoring\u003c\/li\u003e\n\u003cli\u003eCompressor protection systems\u003c\/li\u003e\n\u003cli\u003eMotor vibration analysis\u003c\/li\u003e\n\u003cli\u003eFan monitoring systems\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance programs\u003c\/li\u003e\n\u003cli\u003ePortable vibration data collection\u003c\/li\u003e\n\u003cli\u003ePermanent mounted machinery monitoring\u003c\/li\u003e\n\u003cli\u003eProcess industry rotating equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial asset condition monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eDynamicSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSensitivity at 25 degC\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e100 mV\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eAcceleration Range\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e80 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAmplitude Nonlinearity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e+\/-10%: 1.0-5,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e+\/-3 dB: 0.7-10,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eResonant Frequency\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e22 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eTransverse Sensitivity, Max\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e+\/-5% of axial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eTemperature Response at -55 degC\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eTemperature Response at +120 degC\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e+10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eElectricalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eVoltage Source\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e18-30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eCurrent Regulating Diode\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e2-10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eBroadband Electrical Noise at 2.5 Hz to 25 kHz\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e700 ug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSpectral Electrical Noise at 10 Hz\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e10 ug\/sqrtHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSpectral Electrical Noise at 100 Hz\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e5 ug\/sqrtHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSpectral Electrical Noise at 1000 Hz\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e5 ug\/sqrtHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eOutput Impedance, Max\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e100 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eBias Output Voltage\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eGrounding\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eCase isolated, internally shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eEnvironmentalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-50 degC to 120 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eVibration Limit\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e500 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eShock Limit\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e5,000 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eElectromagnetic Sensitivity, Equivalent g, Max\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e70 ug\/gauss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSealing\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eHermetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eBase Strain Sensitivity, Max\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0.002 g\/ustrain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003ePhysicalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSensing Element Design\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePZT ceramic \/ shear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e145 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eCase Material\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1\/4-28 captive hex head screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eSide exit, 2-pin, MIL-C-5015 style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eRecommended Cabling\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eShielded twisted pair, maximum 100 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eConnections\/Interfaces\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eConnector PinFunction\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eShell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eGround\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eA\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003ePower\/Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eB\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cp\u003eUse shielded twisted-pair cabling to minimize electromagnetic interference in high-noise industrial environments.\u003c\/p\u003e\n\u003cp\u003eMaintain proper grounding practices to avoid unwanted ground loop conditions during permanent installation.\u003c\/p\u003e\n\u003cp\u003eInstall the accelerometer on a clean and rigid mounting surface to maintain vibration signal accuracy.\u003c\/p\u003e\n\u003cp\u003eVerify connector orientation before energizing the sensor to prevent incorrect wiring conditions.\u003c\/p\u003e\n\u003cp\u003eAvoid routing sensor cables alongside high-voltage motor cables or variable frequency drive output wiring.\u003c\/p\u003e\n\u003cp\u003eUse appropriate moisture protection methods when the sensor is installed in washdown or outdoor environments.\u003c\/p\u003e\n\u003cp\u003eConfirm mounting torque and thread engagement before commissioning the monitoring system.\u003c\/p\u003e\n\u003cp\u003eInspect cable shielding continuity during maintenance intervals to maintain signal quality.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of sensor technology is used in this accelerometer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit uses Integrated Electronics Piezo-Electric sensing technology with a PZT ceramic shear element.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor requires a constant-current IEPE power source between 18 and 30 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the sensitivity rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensitivity is 100 mV\/g at 25 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the sensor operate in wet environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hermetically sealed housing supports operation in moisture-prone industrial environments when proper connectors are used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the housing electrically isolated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The case is isolated and internally shielded.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat connector style is used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device uses a side-exit 2-pin MIL-C-5015 style connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum recommended cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe recommended cable length is up to 100 feet using shielded twisted-pair cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting thread is provided?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor uses a 1\/4-28 captive hex head mounting screw.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the sensor be used for permanent monitoring systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is suitable for permanently mounted vibration monitoring installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe operating range is -50 degC to 120 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes reverse wiring damage the sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor includes reverse wiring protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat vibration range can the device measure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe accelerometer supports measurement up to 80 g peak.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat industrial systems can interface with this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor interfaces with condition monitoring and machinery protection systems supporting IEPE inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs EMI\/RFI shielding included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The sensor includes EMI\/RFI shielding to reduce electrical interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572702059,"sku":"AS3100S2-Z0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-as3100s2-z0-sensor-proximity-probe-cable-oyteqcgpfjb_6e0be704-f697-48dd-8542-c7456ac13275.jpg?v=1765440867"},{"product_id":"bently-nevada-9200-06-02-10-00-two-wire-transducer","title":"Bently Nevada 9200-06-02-10-00 Two-Wire Transducer","description":"\u003cp\u003eThe \u003cstrong\u003e9200\u003c\/strong\u003e standard velocity transducer, complete part number \u003cstrong\u003e9200-06-02-10-00\u003c\/strong\u003e, is a two-wire moving-coil transducer designed to measure absolute casing vibration on rotating machinery. The mechanical system features a wire-suspended coil moving around a permanent magnet, providing a voltage output directly proportional to vibration velocity. This self-generating sensor requires no external power and operates within a dedicated orientation window defined by its specific option configuration. The 9200 series utilizes rotor dynamics principles to continuously monitor structural casing movement, ensuring critical machinery protection and interfacing directly with Bently Nevada monitoring systems through low-impedance signal transmission.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-06: Transducer Mounting Angle \/ Minimum Operating Frequency\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e0 ±100° (horizontal placement orientation), 10 Hz (600 cpm) minimum operating frequency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02: Connector Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHermetically sealed side-mount 2-pin connector interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10: Mounting Base Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCircular base geometry featuring an M10X1 threaded stud connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Agency Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo standard hazardous area approvals or certificates required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-02-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Moving-Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100° (Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Operating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSide Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Base Geometry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircular with M10X1 Threaded Stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase and Adapter Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the sensor installation angle precisely matches the 0 ±100° horizontal range specification to avoid physical internal coil binding against the magnet housing.\u003c\/li\u003e\n\u003cli\u003eOperating the transducer below the specified 10 Hz frequency limit causes significant amplitude attenuation and phase shift errors in velocity data.\u003c\/li\u003e\n\u003cli\u003eCross-axis vibration sensitivity must be minimized by aligning the primary measurement axis directly parallel to the intended machinery vibration direction.\u003c\/li\u003e\n\u003cli\u003eThe self-generating coil assembly introduces a fixed internal impedance that must be matched with compatible monitoring instrumentation inputs to prevent signal loading effects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplement dedicated shield grounding protocols by connecting the cable shield at the monitoring rack end only, ensuring the transducer end remains isolated to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing segregation by separating transducer signal lines from high-voltage AC power distribution conduits to reduce electro-magnetic interference.\u003c\/li\u003e\n\u003cli\u003eAvoid exceeding the minimum bending radius of the field wiring cable to prevent internal conductor damage or degradation of the insulation barrier.\u003c\/li\u003e\n\u003cli\u003eVerify the structural integrity of the M10X1 mounting surface, ensuring it is flat, smooth, and free of paint or debris to guarantee accurate high-frequency vibration transmission.\u003c\/li\u003e\n\u003cli\u003eApply correct torque specifications when securing the circular mounting base to the machine casing to prevent resonant frequencies from distorting the velocity readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this 9200-06-02-10-00 model be mounted in a purely vertical orientation on a machine casing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the -06 suffix designates a horizontal mounting configuration of 0 ±100 degrees; vertical mounting requires a different option code to calibrate the internal spring-coil alignment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What components are included inside the shipping box for this specific part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The package contains the brand-new original 9200-06-02-10-00 velocity transducer assembly with its integrated side-mount connector and M10X1 circular mounting base stud.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this specific transducer module require a separate external power supply to output the velocity signal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this is a self-generating electro-magnetic moving-coil sensor that produces its own voltage output relative to velocity without requiring external loop power.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666764493163,"sku":"9200-06-02-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-02-10-00-two-wire-transducer-wh1b32koul4_e61ad530-9ea0-4ba5-a008-11769c81ce20.jpg?v=1765447197"},{"product_id":"bently-nevada-as3100s2-z2-integrated-electronics-piezo-electric-iepe-accelerometer","title":"Bently Nevada AS3100S2-Z2 Integrated Electronics Piezo-Electric (IEPE) Accelerometer","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada AS3100S2-Z2\u003c\/strong\u003e is an Integrated Electronics Piezo-Electric (IEPE) accelerometer engineered for high-density vibration signal acquisition within harsh industrial environments. Operating via a PZT ceramic shear sensing element coupled to an internal charge amplifier, this device converts mechanical acceleration vectors into a proportional low-impedance voltage output over a wide dynamic range. The sensor features a side-exit 2-pin MIL-C-5015 style connector interface, delivers a calibrated nominal sensitivity of 100 mV\/g, and maintains a measurement envelope up to 80 g peak acceleration. It requires a standard 18-30 VDC constant-current power source (2-10 mA) to drive the internal electronics, providing high immunity to electromagnetic interference and radio frequency interference (EMI\/RFI) while presenting a case-isolated design that prevents ground loops in permanent rotor dynamics monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eSensing Element Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePZT ceramic \/ shear mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eNominal Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e100 mV\/g ±5% @ 25 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eAcceleration Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e80 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eAmplitude Nonlinearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eFrequency Response (±10%)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e1.0 Hz to 5,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eFrequency Response (±3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0.5 Hz to 10,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eResonant Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e22 kHz nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eMaximum ±5% of axial alignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eTemperature Response (-55 Celsius)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e-20% deviation baseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eTemperature Response (+120 Celsius)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e+10% deviation baseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eExcitation Voltage Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e18 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eConstant Current Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e2 mA to 10 mA via regulating diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e100 Ohm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eDC Bias Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e12 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eBroadband Noise (2.5 Hz to 25 kHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e700 micro-g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eSpectral Noise @ 10 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e10 micro-g\/root-Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eSpectral Noise @ 100 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e5 micro-g\/root-Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003cstrong\u003eSpectral Noise @ 1,000 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e5 micro-g\/root-Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e-55 Celsius to 120 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003e\u003cstrong\u003eVibration Operational Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e500 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"22\"\u003e\u003cstrong\u003eShock Destruction Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"22\"\u003e5,000 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"23\"\u003e\u003cstrong\u003eElectromagnetic Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"23\"\u003e70 micro-g\/gauss maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"24\"\u003e\u003cstrong\u003eEnclosure Material Housing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"24\"\u003e316L Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"25\"\u003e\u003cstrong\u003eSealing Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"25\"\u003eHermetic seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"26\"\u003e\u003cstrong\u003eBase Strain Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"26\"\u003e0.002 g\/micro-strain maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"27\"\u003e\u003cstrong\u003eMechanical Installation Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"27\"\u003e1\/4-28 UNF tapped hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"28\"\u003e\u003cstrong\u003eElectrical Connection Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"28\"\u003eSide exit, 2-pin, MIL-C-5015 style connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"29\"\u003e\u003cstrong\u003eHazardous Area Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"29\"\u003eZone 2 rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"30\"\u003e\u003cstrong\u003eNet Structural Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"30\"\u003e145 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBias Voltage Diagnostics:\u003c\/strong\u003e Monitoring the 12 VDC nominal bias output voltage serves as a diagnostic tool for sensor health. A significant shift toward the supply rail indicates an open circuit or unpowered condition, while a drop toward 0 VDC indicates a short-circuit fault within the sensor or field cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Isolation:\u003c\/strong\u003e The internal sensing circuit is completely isolated from the outer 316L stainless steel housing and shields, ensuring that case mounting on vibrating machinery structures cannot form parasitic ground paths or corrupt parallel turbomachinery protection monitors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransverse Response Mitigation:\u003c\/strong\u003e To minimize cross-axis signal pollution, ensure the accelerometer axial center-line matches the designated vibration vector exactly; the sensor limits transverse measurement errors to less than ±5% of the primary axial input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Torque Execution:\u003c\/strong\u003e Ensure the mating surface is ground flat and free of debris. Secure the 1\/4-28 UNF mounting stud using a calibrated torque wrench to prevent high-frequency transmission attenuation or artificial resonant peaking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length Constraints:\u003c\/strong\u003e Limit the shielded twisted-pair cabling runs to a maximum length of 100 feet to mitigate parasitic cable capacitance, which can attenuate high-frequency signals and induce phase shifts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubmersion and Connector Sealing:\u003c\/strong\u003e While the housing features a hermetic design, proper environmental boots or IP-rated conduit assemblies must be deployed over the MIL-C-5015 connector pins if the installation site is prone to direct wash-downs or fluid immersion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What is the purpose of the integrated ESD and reverse wiring protection circuits in this IEPE model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The internal circuitry guards the constant-current internal charge amplifier against electrostatic discharge damage during handling and prevents component failure if the power and signal leads are accidentally cross-wired during field termination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What accessories are standard inclusions inside the box for this specific Zone 2 rated part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Every factory package includes one AS3100S2-Z2 side-exit accelerometer sensor, one 1\/4-28 to 1\/4-28 UNF threaded mechanical mounting stud, and the corresponding calibration data sheet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Can this accelerometer be directly connected to a voltage-input monitoring system channel without a constant-current interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: No. As an IEPE style transducer, it requires an external constant-current diode supply providing 2 to 10 mA at 18 to 30 VDC superimposed on the signal line to power its internal amplifier before an AC voltage signal can be read.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666770391403,"sku":"AS3100S2-Z2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-as3100s2-z2-side-exit-sensor-xutqwqi31vp_774d7744-2b11-4072-a4f1-71baaa2189ef.jpg?v=1765447279"},{"product_id":"bently-nevada-9200-06-05-05-00-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-06-05-05-00 Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-06-05-05-00\u003c\/strong\u003e is a two-wire \u003cstrong\u003evelocity transducer\u003c\/strong\u003e designed for continuous monitoring or periodic diagnostics of absolute casing, bearing housing, or structural vibration. Utilizing moving-coil technology, this instrument generates a voltage output directly proportional to the transducer's vibration velocity without requiring external operating power. The unique mechanical architecture of the \u003cstrong\u003e9200-06-05-05-00\u003c\/strong\u003e ensures low sensitivity to impact or impulsive excitation, delivering highly reliable and repeatable dynamic data on critical machinery such as turbines, pumps, and industrial fans.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMoving-coil technology provides a direct voltage output without the need for external power.\u003c\/li\u003e\n\u003cli\u003eLow sensitivity to impact or impulsive excitation compared to solid-state alternatives.\u003c\/li\u003e\n\u003cli\u003eTwo-wire engineering supports both permanent machinery protection and portable field measurements.\u003c\/li\u003e\n\u003cli\u003eDurable anodized aluminum case construction for survival in aggressive industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAbsolute bearing housing and machinery casing vibration measurements.\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbine casing monitoring protocols.\u003c\/li\u003e\n\u003cli\u003ePeriodic data collection using portable test and diagnostic equipment.\u003c\/li\u003e\n\u003cli\u003eStructural vibration analysis on large-scale balance-of-plant equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFactory Configuration Profile\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Mounting Angle\/Minimum Operating Frequency: 0 ±100, 10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Option: Terminal block top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: No base; 1\/2-in 20 UNF-3A stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-05-05-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) ±5% at +22 Celsius (+72 Fahrenheit) with 25 mm\/s (1 in\/s) vibration at 100 Hz into a 10 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1 kHz (60,000 cpm); +0, -3dB typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100 (Vertical, viewed from driver end)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithstands 50 g peak maximum acceleration along non-sensitive axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Leadwire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) between transducer and 3300 or 3500 Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating\/Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 Celsius to +121 Celsius (-20 Fahrenheit to +250 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasket Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide with nickel-plated copper contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Base Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo base; 1\/2-in 20 UNF-3A stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78.54 mm (3.092 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.40 mm (1.63 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Output (Pin A goes positive with respect to Pin B when case velocity is toward connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Alignment:\u003c\/strong\u003e The transducer must be physically mounted within its designated 0 ±100 vertical limits relative to the calibration angle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Rating:\u003c\/strong\u003e Tighten the integrated 1\/2-in 20 UNF-3A mounting thread to exactly 5.6 Nm (50 in-lb) to guarantee optimal frequency transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Path:\u003c\/strong\u003e Ensure the chosen structural interface point faithfully transmits internal rotor malfunctions to the external casing where the transducer sits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e Verify that the top terminal block connector is fully buttoned up and sealed against regional dust and moisture entry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 05 mounting base configuration indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -05 code indicates that the transducer is supplied with no separate circular or rectangular flange base; instead, it features an integrated 1\/2-in 20 UNF-3A threaded stud directly on the bottom for mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum operating frequency limits of this velocity sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model incorporates the -06 frequency option, establishing a low-end frequency limit of 10 Hz (600 cpm) before signal attenuation starts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the moving-coil principle benefit this transducer over standard accelerometers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause it utilizes moving-coil technology rather than solid-state integration crystals, it is substantially more resilient and less sensitive to mechanical impacts or abrupt impulsive shocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an external power supply or charge amplifier required for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this two-wire velocity system is entirely self-generating and creates a direct voltage output signal from the internal coil movement, making it highly versatile for portable and diagnostic tasks.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666853720427,"sku":"9200-06-05-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-05-05-00-velocity-seismoprobe-w514jt2zgqz_3f2acb0a-f4fb-455f-8d51-77fd859d0a50.jpg?v=1765449119"},{"product_id":"bently-nevada-9200-03-05-10-00-9200-series-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-03-05-10-00 9200 Series Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e9200-03-05-10-00\u003c\/strong\u003e is a 2-wire moving-coil velocity transducer engineered for the absolute vibration measurement of casing structures, bearing housings, or structural components. Operating on a self-generating electrodynamic principle, this \u003cstrong\u003e9200-03-05-10-00\u003c\/strong\u003e seismoprobe transforms mechanical velocity into a proportional voltage signal without requiring external excitation power. Its moving-coil design delivers robust resistance against false trips or signal degradation typically induced by impact, shock, or impulsive excitation near reciprocating or heavy rotating equipment. The transducer features a top-mounted terminal block interface for field electrical termination and mounts onto flat machine surfaces via a threaded stud, allowing direct integration into machinery protection systems, distributed control systems (DCS), or plant asset management monitors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrodynamic moving-coil architecture providing high immunity to false trips caused by shock or high-frequency impact.\u003c\/li\u003e\n\u003cli\u003ePassive, self-generating design eliminates the need for external loop or module power supplies.\u003c\/li\u003e\n\u003cli\u003e2-wire electrical connectivity for straightforward field wiring and long-distance signal transmission.\u003c\/li\u003e\n\u003cli\u003eTop-mounted terminal block layout facilitates flexible configuration of regional field cables.\u003c\/li\u003e\n\u003cli\u003eRugged construction designed to maintain measurement fidelity under continuous machinery case vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHorizontal vibration monitoring on large industrial pumps and fans.\u003c\/li\u003e\n\u003cli\u003eBearing housing casing velocity measurements on steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eStructural monitoring of gearbox casings and support frames.\u003c\/li\u003e\n\u003cli\u003eCasing vibration tracking on industrial motors, generators, and blowers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series: 9200 Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Angle Option: Horizontal (90 degrees +-2.5 degrees), 4.5 Hz minimum operating frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Option: Top-mount terminal block electrical connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: M10x1 threaded mounting stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprovals Option: No hazardous area certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-03-05-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoving-Coil Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive electrodynamic (self-generating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) +-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 1,000 Hz (+0 dB, -3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 degC to +121 degC (-20 degF to +250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal (90 degrees +-2.5 degrees)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm (4 in) typical (depending on connector option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 mm (1.6 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Mounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.41 Nm (12.5 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Block Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Signal Output (Velocity Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Signal Output (Signal Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Preparation:\u003c\/strong\u003e Prepare a flat, clean, and smooth surface on the machine bearing housing or casing. Ensure the area is free of rust, paint, or grease to guarantee proper mechanical transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Threading:\u003c\/strong\u003e Secure the transducer tightly to the prepared surface utilizing the M10x1 threaded mounting stud. Tighten the base mounting stud to a torque specification of 5.6 Nm (50 in lb). Adhere strictly to this limit to prevent casing distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Verification:\u003c\/strong\u003e Align the transmitter strictly for horizontal operation (90 degrees +-2.5 degrees from vertical). Misalignment outside this window alters internal suspension physics and leads to severe measurement errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e When attaching field wiring components, tighten the connector terminals to a specification of 1.41 Nm (12.5 in lb) to establish secure electrical contact without damaging the hardware threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Selection:\u003c\/strong\u003e Use a high-quality, twisted 2-conductor shielded instrument cable to run signals from the top terminal block to the instrumentation rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect the cable shield wire cleanly to the instrumentation or monitor ground at the control room end only. Insulate the shield wire at the transducer terminal box to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpact Prevention:\u003c\/strong\u003e Avoid hitting or dropping the transducer housing during installation procedures to safeguard the internal moving-coil mechanism from structural deformation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864140651,"sku":"9200-03-05-10-00 Transducer","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-03-05-10-00-transducer-ijg1gb5zujl_0d2232c9-47af-4f9b-9832-a31333d0d0bf.jpg?v=1765449391"},{"product_id":"bently-nevada-9200-01-02-10-00-seismoprobe-transducer","title":"Bently Nevada 9200-01-02-10-00 Seismoprobe Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-01-02-10-00\u003c\/strong\u003e is a two-wire \u003cstrong\u003eSeismoprobe Velocity Transducer\u003c\/strong\u003e designed to measure absolute casing vibration on rotating machinery. This moving-coil transducer provides a voltage output directly proportional to the vibration velocity of the machine housing. It operates without external power, utilizing a self-generating design that simplifies field wiring and integration into continuous monitoring systems. The \u003cstrong\u003e9200-01-02-10-00\u003c\/strong\u003e is typically connected to machinery protection systems, such as the Bently Nevada 3500 series, to provide continuous machinery diagnostics, early fault detection, and structural vibration evaluation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelf-generating, moving-coil design requires no external power source.\u003c\/li\u003e\n\u003cli\u003eTwo-wire connection configuration minimizes wiring complexity.\u003c\/li\u003e\n\u003cli\u003eHigh sensitivity to low-frequency machinery casing vibration.\u003c\/li\u003e\n\u003cli\u003eDurable construction suitable for harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003eContinuous online monitoring capabilities for structural and casing velocity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge rotating machinery casing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial fans, blowers, and air handling units\u003c\/li\u003e\n\u003cli\u003eCentrifugal pumps and compressors\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbine housing diagnostics\u003c\/li\u003e\n\u003cli\u003eElectric motor and gearbox structural analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e9200: Two-wire Seismoprobe Velocity Transducer\u003c\/li\u003e\n\u003cli\u003e01: Standard Temperature Version\u003c\/li\u003e\n\u003cli\u003e02: Transducer Mount Option\u003c\/li\u003e\n\u003cli\u003e10: Minimum operating frequency option\u003c\/li\u003e\n\u003cli\u003e00: No Hazardous Area Approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSeismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSensitivity\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e20 mV\/mm\/s (500 mV\/in\/s) plus or minus 5 percent at 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e10 Hz to 1000 Hz plus or minus 3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-29 to +121 Celsius (-20 to +250 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eVertical or horizontal based on option selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eCase Material\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eIntegral cable or top connector variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eEstimated Weight\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eApproximately 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eApprox. 41 mm diameter by 102 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003ePin A \/ Red Wire\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePositive (+) Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003ePin B \/ White Wire\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eNegative (-) Signal \/ Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eShield\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eCase Ground \/ Shield Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Alignment:\u003c\/strong\u003e Ensure the transducer is mounted exactly within its specified orientation limits (vertical or horizontal) to maintain specified accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Preparation:\u003c\/strong\u003e The mounting surface must be flat, smooth, clean, and torque to the recommended engineering specification to ensure proper frequency transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate the cable shield at the monitoring system chassis ground only. Do not connect the shield at the transducer end to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route transducer cables through dedicated conduit or cable trays away from high-voltage lines and heavy electrical machinery to reduce EMI\/RFI noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection:\u003c\/strong\u003e Apply proper environmental sealing or weatherproofing boots to the connector assembly when operating in high humidity or outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core operating principle of the transducer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt utilizes a moving-coil and permanent magnet assembly that generates a voltage output directly proportional to the velocity of the physical vibration without external electrical power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model require an external proximity probe driver or transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it is a self-generating velocity sensor that interfaces directly with the processing monitor card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a vertical transducer is mounted horizontally?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal spring-mass assembly will misalign, causing internal friction, inaccurate readings, and potential damage to the internal coil suspension.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the cable shield be terminated for field installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shield must be insulated at the transducer housing and connected cleanly to the instrument ground inside the monitoring cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be repaired in the field if the housing is damaged?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the transducer is a factory-sealed unit and must be replaced or returned to the manufacturer for recalibration and service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical output impedance of this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt features a low output impedance design making it suitable for driving long transmission cables without significant signal degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs calibration required during initial installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is factory-calibrated and does not require field adjustment, though periodic verification of the sensitivity parameter is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes signal distortion or clipping in this type of sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSevere mechanical shocks exceeding the physical limits of the internal mass suspension can cause internal bottoming and signal distortion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the transducer be painted during routine machinery maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePainting the sensor body is not recommended as it can trap heat, obscure identification labels, and potentially foul the mounting base coupling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does ambient temperature affect the sensitivity of the unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensitivity remains highly stable across the specified operating temperature range, with minor variance accounted for in the engineering verification data.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866794859,"sku":"9200-01-02-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-01-02-10-00-seismoprobe-transducer-akmea2itopi_2a477c9a-18b7-4ceb-998c-500cda761ba9.jpg?v=1765449481"},{"product_id":"bently-nevada-9200-06-05-10-00-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-06-05-10-00 Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-06-05-10-00\u003c\/strong\u003e is a two-wire \u003cstrong\u003evelocity transducer\u003c\/strong\u003e engineered for continuous monitoring or periodic measurements of absolute structural, casing, or bearing housing vibration. Operating via moving-coil technology, this system delivers a voltage output directly proportional to the mechanical vibration velocity without requiring an external power source. The \u003cstrong\u003e9200-06-05-10-00\u003c\/strong\u003e configuration is specifically less sensitive to impact or impulsive excitation compared to solid-state sensors, making it ideal for standard casing velocity applications across critical machinery like turbines, fans, and pumps.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire moving-coil technology design providing an direct voltage output without external power\u003c\/li\u003e\n\u003cli\u003eReduced sensitivity to impact or impulsive excitation compared to solid-state alternatives\u003c\/li\u003e\n\u003cli\u003eSuitable for both continuous machinery protection and periodic portable diagnostics\u003c\/li\u003e\n\u003cli\u003eHigh-grade anodized aluminum casing providing robust resistance to industrial environmental factors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAbsolute bearing housing and casing vibration measurement on rotating machinery\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbine structural vibration monitoring\u003c\/li\u003e\n\u003cli\u003ePortable test instrument data collection and diagnostics\u003c\/li\u003e\n\u003cli\u003eBalance and misalignment tracking on heavy industrial fans and pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFactory Configuration Profile\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Mounting Angle\/Minimum Operating Frequency: 0 ±100, 10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Option: Terminal block top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: Circular; M10X1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-05-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) ±5% at +22 Celsius with 25 mm\/s of casing vibration at 100 Hz under 10 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom 10 Hz to 1 kHz (60,000 cpm); +0, -3dB typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100 (Vertical, viewed from driver end)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithstands 50 g peak maximum acceleration along non-sensitive axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Leadwire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) between transducer and 3300\/3500 Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 Celsius to +121 Celsius (-20 Fahrenheit to +250 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasket Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block top mount (Polyphenylene Sulfide with nickel-plated copper contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircular; M10X1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78.54 mm (3.092 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.40 mm (1.63 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Signal Out (Signal goes positive with respect to B when case velocity moves toward connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Signal Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Alignments:\u003c\/strong\u003e Ensure the transducer is installed strictly within its specified 0 ±100 vertical boundaries relative to the machine axis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Application:\u003c\/strong\u003e Tighten the M10X1 mounting base option to exactly 5.6 Nm (50 in-lb) during seating to preserve optimal amplitude and frequency response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Fidelity:\u003c\/strong\u003e Verify that structural or rotor vibration paths are faithfully transmitted to the bearing housing or casing location chosen for the transducer installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Countermeasures:\u003c\/strong\u003e Ensure the top-mounted terminal block enclosure is sufficiently protected against dust and moisture ingestion to fit local environmental ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 9200-06-05-10-00 require an external power supply to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this transducer leverages a moving-coil architecture which inherently creates its own voltage signal output proportional to the vibration velocity without external power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum operating frequency threshold for this precise configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific unit uses the -06 option, which defines a minimum operating frequency threshold of 10 Hz (600 cpm).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the sensor signal cable be handled over long distances?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system supports up to 305 meters of leadwire between the velocity sensor and a 3300 or 3500 series monitor, though you should consult the manual for high-frequency roll-off parameters when using extended lengths.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary differences between this moving-coil sensor and solid-state alternatives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMoving-coil sensors display much lower sensitivity to impact or impulsive excitations compared to embedded integration solid-state alternatives, providing specific advantages on designated casing installations.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867712363,"sku":"9200-06-05-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-05-10-00-velocity-seismoprobe-jzrvpejc0gv_9b3aa907-a1c6-44fd-96f1-814ed8ac1a38.jpg?v=1765449515"},{"product_id":"bently-nevada-9200-01-02-02-00-two-wire-transducer","title":"Bently Nevada  9200-01-02-02-00 Two-wire Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 9200-01-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a two-wire vibration transducer designed for continuous measurement of machinery vibration in pumps, fans, compressors, and general-purpose industrial rotating equipment. It provides a compact and cost-effective monitoring solution for condition-based maintenance systems where full proximity probe architecture is not required.\u003c\/p\u003e\n\u003cp\u003eThis transducer is widely used in auxiliary machinery protection systems across power plants, water treatment facilities, and process industries. It converts mechanical vibration into a proportional electrical signal suitable for direct connection to monitoring and control systems.\u003c\/p\u003e\n\u003cp\u003eThe side-mount connector and circular 1\/4 in 28 UNF stud base support flexible installation on standard machine housings, ensuring stable mechanical coupling and consistent vibration transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9200\u003c\/td\u003e\n\u003ctd\u003eTwo-wire vibration transducer series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eMounting angle and minimum operating frequency option (0 ±2.5, 4.5 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eSide-mount connector configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eCircular base with 1\/4 in 28 UNF stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines mechanical orientation, connector position, and mounting interface within the 9200 series transducer architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9200-01-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-wire vibration transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eSide mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base\u003c\/td\u003e\n\u003ctd\u003eCircular, 1\/4 in 28 UNF stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz minimum (270 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Angle\u003c\/td\u003e\n\u003ctd\u003e0 ±2.5 configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003eTwo-wire loop powered system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe two-wire design simplifies installation by combining power supply and signal transmission in a single loop configuration. This reduces wiring complexity in distributed monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe circular stud mounting base ensures stable mechanical coupling to machine surfaces, which is critical for accurate vibration transmission.\u003c\/p\u003e\n\u003cp\u003eLow-frequency response capability allows monitoring of slow-speed machinery where traditional high-frequency sensors may not provide sufficient sensitivity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this transducer typically used?\u003c\/strong\u003e\u003cbr\u003eIt is used in general industrial machinery such as pumps, fans, and auxiliary compressors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for high-speed turbine monitoring?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed for general-purpose machinery, not high-precision turbine proximity measurement systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of two-wire design?\u003c\/strong\u003e\u003cbr\u003eIt reduces wiring complexity by combining signal and power in a single loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used in legacy monitoring systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly used in retrofit and general-purpose condition monitoring applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure solid mechanical mounting using the 1\/4 in 28 UNF stud to guarantee accurate vibration transmission from machine surface to sensor body.\u003c\/p\u003e\n\u003cp\u003eAvoid loose mounting conditions, as poor mechanical coupling directly affects signal accuracy.\u003c\/p\u003e\n\u003cp\u003eRoute transducer wiring away from high-voltage and motor drive cables to minimize electrical noise interference.\u003c\/p\u003e\n\u003cp\u003eVerify correct loop power configuration before commissioning to ensure stable signal output.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper surface preparation before installation to ensure flat and stable mounting contact.\u003c\/p\u003e\n\u003cp\u003eUse torque-controlled tightening for stud mounting to prevent mechanical stress damage to the housing.\u003c\/p\u003e\n\u003cp\u003eAvoid installing in areas with excessive structural resonance that may distort vibration readings.\u003c\/p\u003e\n\u003cp\u003ePeriodically inspect mounting integrity in high-vibration environments to ensure long-term measurement stability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321268075,"sku":"9200-01-02-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-01-02-02-00-lyutop23y3j_d66bbd30-1837-4d70-a2d9-9f4778f18244.jpg?v=1765521151"},{"product_id":"bently-nevada-9200-03-24-10-00-two-wire-velocity-seismoprobe-transducer","title":"Bently Nevada 9200-03-24-10-00 Two-wire Velocity Seismoprobe Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9200-03-24-10-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etwo-wire velocity Seismoprobe transducer from Bently Nevada is designed for continuous vibration monitoring of industrial rotating and reciprocating machinery. It is widely used in power generation plants, oil and gas facilities, compressors, pumps, and heavy industrial systems where accurate vibration measurement is required to ensure machine reliability and reduce unplanned downtime.\u003c\/p\u003e\n\u003cp\u003eThis velocity transducer operates on a two-wire configuration, simplifying field wiring while maintaining stable signal transmission for condition monitoring systems. The mounting configuration supports a circular M10x1 stud, providing secure mechanical installation in industrial environments with high vibration levels. The 90 degree ±2.5 mounting angle option and 4.5 Hz minimum operating frequency ensure stable low-frequency response for slow-speed machinery applications. The environmentally resistant integral cable connector allows direct installation in exposed environments. With a compact body design and rugged construction, the device maintains consistent performance under harsh operational and thermal conditions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eMounting angle 90 degree ±2.5, minimum operating frequency 4.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003eEnvironmentally resistant connector with integral cable (custom length 2.1 m to 15 m range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eCircular mounting base with M10x1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9200-03-24-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eCircular base M10x1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Angle\u003c\/td\u003e\n\u003ctd\u003e90 deg ±2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Frequency\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eIntegral cable, environmentally resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Range\u003c\/td\u003e\n\u003ctd\u003e2.1 m to 15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e102 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e41 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eVelocity vibration sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of a two-wire velocity transducer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt simplifies installation by reducing wiring complexity while maintaining reliable vibration signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transducer be used in low-speed machinery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports a low-frequency response down to 4.5 Hz, suitable for slow-speed equipment monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable length adjustable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The integral cable option supports lengths from 2.1 m up to 15 m depending on installation requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this suitable for outdoor industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The environmentally resistant connector and rugged housing support harsh field conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eEnsure the mounting stud is tightened according to manufacturer torque specifications to maintain accurate vibration coupling.\u003c\/p\u003e\n\u003cp\u003eRoute signal cables away from high voltage and VFD lines to reduce electromagnetic interference in vibration measurement systems.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable strain relief to prevent connector fatigue in high vibration installations.\u003c\/p\u003e\n\u003cp\u003eAvoid installing near high thermal radiation sources to preserve sensor stability and long-term accuracy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322349419,"sku":"9200-03-24-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-03-24-10-00-kul4bizo52s_0af56f41-8cb1-467a-aa7e-5c3c3e17f1b5.jpg?v=1765521195"},{"product_id":"bently-nevada-200350-00-00-cn-accelerometer-piezoelectric-velocity-sensor","title":"Bently Nevada 200350-00-00-CN Accelerometer Piezoelectric Velocity Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200350-00-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rugged, general-purpose piezoelectric accelerometer designed for casing vibration measurements on critical rotating machinery. Within high-demand sectors such as power generation, oil and gas, and wastewater treatment, this sensor plays a critical role in monitoring high-frequency vibrations typically associated with gear mesh and rolling element bearing defects. By integrating this sensor into a Bently Nevada Trendmaster or similar Condition Monitoring System, engineers can identify subtle mechanical changes before they escalate into significant failures. This proactive data stream is essential for optimizing maintenance schedules, reducing unplanned outages, and extending the operational life of motors, pumps, and fans in harsh industrial environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric designation of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200350-00-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefines its mechanical interface and regional compliance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e200350:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase model for the 100 mV\/g Accelerometer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00 (Mounting Stud):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a 1\/4-28 Stainless Steel mounting stud equipped with a brass tip (0.5 inch length).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00 (Tolerance):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies a standard sensitivity of 100 mV\/g with a plus or minus 20 percent tolerance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-CN (Agency Approvals):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMandatory China-specific approvals.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe product is fully certified by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEPSI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand carries the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCC (China Compulsory Certificate)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor explosion-proof safety, adhering to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGB 3836\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandards for hazardous area use in the Chinese market.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200350-00-00-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mV\/g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Hz to 10 kHz (plus or minus 3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4-28 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-54 to +121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHex Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11\/16 inch (1.8 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.65 inch (4.24 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.051 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Insights \u0026amp; FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the specific advantages of the -CN version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix denotes that the accelerometer is legally compliant with Chinese national standards. It has undergone the necessary certification processes by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEPSI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto meet\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements, ensuring it is safe and authorized for installation in hazardous industrial zones across China under the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGB 3836\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eframework.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this accelerometer connect to monitoring systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 200350 series typically utilizes a standard 2-pin MIL-style connector. It requires a constant current power source (ICP\/IEPE compatible) to operate, which is usually provided by the monitoring rack or an interface module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this sensor be used for low-frequency vibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile this accelerometer has a wide frequency range starting from 0.5 Hz, it is primarily optimized for high-frequency vibration detection. For very low-speed machinery (below 100 RPM), we recommend consulting Bently Nevada's low-frequency specific sensor catalog for better signal-to-noise ratios at low speeds.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSurface Preparation and Mounting Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor accurate high-frequency data, the mounting surface must be flat, smooth, and clean. Even minor surface irregularities can act as a low-pass filter, attenuating high-frequency signals. Use the 11\/16 inch hex base to tighten the sensor. Apply a mounting torque of approximately 2.7 to 4.5 Nm (24 to 40 in-lb). Over-tightening can damage the internal piezoelectric element, while under-tightening leads to resonance errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChina Ex\/NEPSI Safety Protocols\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo maintain the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEPSI\/CCC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexplosion-proof integrity, always install this sensor with a certified intrinsic safety barrier if the environment is classified as hazardous. Use only approved, shielded cabling and ensure the cable armor is properly grounded at the system end to prevent electromagnetic interference (EMI) from corrupting the vibration signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Stud and Brass Tip\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 0.5 inch 1\/4-28 SS stud with a brass tip (Option 00) provides a secure mechanical interface while the brass tip helps protect the machine surface from scarring. Ensure the stud is fully seated in both the sensor and the machine casing. For permanent installations, a light coating of silicone grease or acoustic coupling fluid between the sensor base and the machine surface can improve the frequency response at higher ranges.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323103083,"sku":"200350-00-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/200350-00-00-cn-dfd0pmx0j1o_f312063e-bfeb-43e4-990b-83c002dab03c.jpg?v=1765521220"},{"product_id":"16710-36-bently-nevada-accelerometer-acceleration-transducers","title":"16710-36 | Bently Nevada | Accelerometer Acceleration Transducers","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16710-36\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada accelerometer acceleration transducer designed for vibration monitoring in rotating and reciprocating machinery across industries such as power generation, oil and gas, and heavy manufacturing. This sensor measures dynamic acceleration signals and converts them into electrical outputs for condition monitoring systems. Engineers deploy this transducer to detect imbalance, looseness, and structural resonance in equipment such as motors, pumps, and compressors. Its integrated armored cable enhances durability in harsh environments while maintaining signal stability. The reliable acceleration measurement supports predictive maintenance strategies, helping reduce unexpected downtime and improving overall equipment reliability.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code defines cable configuration and length:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16710\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= 3 conductor shielded 22 AWG armored cable with 3 socket plug and terminal lugs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e36\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Cable length 36 ft, approximately 10.97 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration ensures proper signal transmission and installation flexibility for industrial monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16710-36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard compact accelerometer form\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRequires external monitoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3 conductor shielded 22 AWG armored cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e36 ft or 10.97 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDynamic acceleration signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary application of this accelerometer?\u003c\/strong\u003e\u003cbr\u003eIt measures machine vibration acceleration for condition monitoring and fault detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transducer operate in harsh industrial environments?\u003c\/strong\u003e\u003cbr\u003eYes. The armored cable and rugged design support operation in demanding conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes signal noise in acceleration measurements?\u003c\/strong\u003e\u003cbr\u003eImproper grounding, cable damage, or routing near high voltage sources can introduce noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this sensor compatible with Bently Nevada monitoring systems?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates with standard Bently Nevada vibration monitoring systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the shielded cable away from high voltage lines to minimize electromagnetic interference.\u003cbr\u003eEnsure proper grounding of the shielding layer to maintain signal integrity.\u003cbr\u003eMount the sensor securely on a clean, flat surface to achieve accurate vibration transmission.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323463531,"sku":"16710-36","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16710-36-205t3ejj1ts_c6c9783b-de59-4241-8613-e7d38ffdb989.jpg?v=1765521232"},{"product_id":"bently-nevada-74712-06-05-03-00-74712-high-temperature-two-wire-transducer","title":"Bently Nevada 74712-06-05-03-00 | 74712 High-Temperature Two-Wire Transducer","description":"\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-03-00\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a heavy-duty, high-temperature two-wire seismic vibration transducer engineered for aggressive machinery protection systems. This specialized sensor is primarily deployed in gas and steam turbine power plants, petrochemical refineries, and heavy steel mills where standard vibration probes fail due to excessive ambient heat. By generating a continuous, proportional velocity signal from critical rotating machinery castings and bearing housings, it provides instant diagnostic visibility. Installing this highly stable seismic sensor ensures real-time detection of structural imbalance, mechanical looseness, and bearing degradation. This predictive monitoring directly mitigates catastrophic failures, extends operational runtimes, and prevents costly unplanned downtime in critical high-heat processes.\u003c\/p\u003e\n\u003ch3\u003eCode Allocation \u0026amp; Suffix Decoupling\u003c\/h3\u003e\n\u003cp\u003eThe specialized model number structure of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseismic transducer translates to the following factory mechanical configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e74712\u003c\/strong\u003e: Base model designation for the Bently Nevada High-Temperature Two-Wire Seismic Transducer series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: Transducer Mounting Angle\/Minimum Operating Frequency Option specifying a 0 plus\/minus 100 degrees mounting orientation with a 10 Hz (600 cpm) minimum operating frequency threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Mounting Base Option designating no integrated base, utilizing a standard 1\/2-in 20 UNF-3A mounting stud.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Connector Option featuring a ruggedized, top-mounted integrated terminal block for simplified field wire connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval Option denoting a standard, non-certified build for non-hazardous industrial areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertified Mechanical \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Metric Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e74712-06-05-03-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeismic Velocity (Two-wire loop powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Angle Orientation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 plus\/minus 100 degrees vertical alignment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Operating Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz (600 cpm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-in 20 UNF-3A stud (no base)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTermination Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTop-mount terminal block connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTypical Housing Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e41 mm (1.6 in) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Core Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.48 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGross Shipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (including rugged shock-absorbent packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Diagnostics \u0026amp; Integration FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary operational advantage of the 10 Hz (600 cpm) low-frequency limit specified by Option 06?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 10 Hz low-frequency limit enables the sensor to accurately monitor low-speed structural vibrations and bearing casing movements common in heavy industrial machinery, filtering out slow-frequency thermal expansion while preserving high-frequency rotational data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the top-mounted terminal block option simplify installation compared to integrated cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"03\" top-mount terminal block design allows field technicians to terminate existing industrial field cabling directly onto the sensor body. This eliminates the need for expensive molded proprietary connectors and simplifies cable replacements in tight, high-temperature conduits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this transducer be mounted in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \"06\" option limits the functional orientation to 0 plus\/minus 100 degrees (typically vertical or near-vertical). Mounting this transducer outside of this specified angular tolerance will cause the internal seismic mass to drift off-center, leading to inaccurate readings and physical internal wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Manual\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Mechanical Coupling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the mounting surface of the machine housing is flat, clean, and free of paint or rust before mounting. Thread the 1\/2-in 20 UNF-3A mounting stud into the machine casing. Apply a thin layer of silicone grease to the mating surfaces and tighten the transducer to the recommended installation torque to ensure perfect acoustic coupling for dynamic vibration transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Temperature Cable Strain Relief:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen wiring the top-mounted terminal block in extreme temperature zones, use high-temperature rated, shielded twisted-pair cabling. Provide a generous cable loop (strain relief) immediately exiting the terminal block to prevent high-amplitude mechanical vibration from putting physical stress on the wire termination screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Ground Loop Prevention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the cable shield wire to the instrument common ground at the monitor or DCS end only. Do not ground the cable shield at the transducer terminal block or machine casing. This single-point grounding layout prevents ground loops and blocks electromagnetic interference (EMI) from adjacent high-power motor drivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323561835,"sku":"74712-06-05-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-06-05-03-00-5nhmfoh3mdd_5c3f81cf-6735-4129-b6ef-4b0b7c8cff34.jpg?v=1765521236"},{"product_id":"74712-06-05-04-00-bently-nevada-high-temperature-two-wire-transducer","title":"74712-06-05-04-00 Bently Nevada High-Temperature Two-Wire Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty, high-temperature seismic velocity transducer engineered by Bently Nevada for the most demanding industrial environments. Specifically designed to monitor vibration on gas turbines, steam turbines, and other rotating machinery where surface temperatures exceed the limits of standard sensors, this two-wire transducer provides a self-generated electrical signal proportional to vibration velocity. Its robust construction ensures reliable performance in the high-heat zones of power generation and petrochemical facilities, allowing for continuous monitoring of critical assets to prevent costly mechanical failure and extend the Mean Time Between Failures (MTBF).\u003c\/p\u003e\n\u003ch3\u003eSuffix Logic Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe specific hardware configuration for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by the following industrial options:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e74712\u003c\/strong\u003e: Base model for the High-Temperature Two-Wire Velocity Transducer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-90\"\u003e\u003c\/span\u003e\u003cstrong\u003e06 (Mounting Angle\/Freq Option)\u003c\/strong\u003e\u003cspan class=\"citation-90 citation-end-90\"\u003e: Optimized for a mounting angle of 0 plus or minus 100 degrees, with a minimum operating frequency of 10 Hz (600 cpm).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Mounting Base Option)\u003c\/strong\u003e: Supplied without a base; features a direct 1\/2-in 20 UNF-3A integrated stud for rigid mechanical coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04 (Connector Option)\u003c\/strong\u003e: Configured with a side-mount connector interface, ideal for installations with limited vertical overhead clearance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Agency Approval Option)\u003c\/strong\u003e: Standard non-certified version for general industrial use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e74712-06-05-04-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-Wire Velocity Transducer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin Operating Freq\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz (600 cpm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Angle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 +\/- 100 degrees\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Stud\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-in 20 UNF-3A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSide Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e41 mm (1.6 in) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.48 kg (1.06 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn what specific scenarios is a side-mount connector (Option 04) preferred?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe side-mount configuration is critical for turbine housings or bearing pedestals where the surrounding heat shielding or acoustic enclosures provide insufficient vertical space for a top-exit cable. It also assists in creating a natural \"drip loop\" to prevent moisture from following the cable into the connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transducer require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-89\"\u003eAs a velocity transducer based on moving-coil technology, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan class=\"citation-89 citation-end-89\"\u003e\u003cspan\u003e \u003c\/span\u003eis self-generating.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt converts mechanical vibration directly into a voltage signal, which simplifies field wiring and reduces the risk of electronic component failure in high-heat zones.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 10 Hz minimum frequency?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis frequency rating ensures the sensor is tuned to capture the fundamental rotational speeds and primary harmonics of large-scale turbines (600 rpm and above). It is not recommended for very slow-speed machinery where frequencies drop below 10 Hz.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Isolation and Cable Selection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis rated for high temperatures, the longevity of the installation depends heavily on the cabling. Always use high-temperature TFE-insulated shielded cables. Ensure the side-mount connector is securely tightened and, if necessary, protected by a heat-reflective sleeve to prevent localized \"hot spots\" from degrading the connector seals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Integrity and Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1\/2-in 20 UNF stud (Option 05) provides a massive, rigid connection point necessary for accurate seismic vibration transmission. Ensure the mounting surface is machined flat to a 0.001-inch total indicator reading. Apply appropriate torque to prevent the sensor from loosening under high-vibration conditions, as any \"sensor rattle\" will manifest as high-frequency noise in the vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrientation Awareness\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"06\" option is designed for near-horizontal mounting. Significant deviation from the specified mounting angle (outside the +\/- 100-degree range) can cause the internal moving coil to contact the housing walls, resulting in \"clipped\" signals and inaccurate vibration readings. Always verify the machine surface angle before installation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324053355,"sku":"74712-06-05-04-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-06-05-04-00-g0ib0cc4duz_7b5a4c3a-dec7-4315-957f-3f91417ce102.jpg?v=1765521256"},{"product_id":"bently-nevada-330425-02-cn-accelerometer-acceleration-transducer","title":"Bently Nevada 330425-02-CN Accelerometer Acceleration Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330425-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance piezoelectric accelerometer from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330400 series\u003c\/strong\u003e. Unlike proximity probes that measure displacement, this transducer measures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eacceleration\u003c\/strong\u003e, making it ideal for monitoring high-frequency vibration associated with gear teeth mesh, rolling element bearing defects, and aerodynamic\/hydrodynamic phenomena.\u003c\/p\u003e\n\u003cp\u003eDesigned for critical machinery protection, the 330425 provides a wide frequency response and a rugged construction capable of withstanding harsh industrial environments. The \"CN\" version is specifically certified to meet regional hazardous area standards for the Chinese market.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe part number breakdown identifies the mounting and certification specifics for this transducer:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel 330425:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA standard industrial accelerometer providing a voltage output proportional to acceleration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Thread (02):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM8 x 1 integral stud\u003c\/strong\u003e. This metric mounting interface ensures a rigid, high-stiffness connection to the machine casing, which is essential for accurate high-frequency data acquisition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval (CN):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComplies with country-specific regulations for China (such as NEPSI), allowing for installation in potentially explosive atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePiezoelectric Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes internal ceramic crystals that generate an electrical charge when subjected to vibration, which is then converted to a low-impedance voltage signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330425-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 mV\/m\/s² (25 mV\/g) ±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz to 15 kHz (±3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmplitude Linearity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±1% up to 735 m\/s² (75 g) peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResonant Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;30 kHz (mounted)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 kg (Transducer only)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 N·m (40 in·lb) maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should I use an accelerometer instead of a proximity probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProximity probes are best for \"soft-bearing\" machines where the shaft moves significantly within the bearing (measuring relative displacement). Accelerometers are preferred for \"hard-bearing\" machines or high-frequency applications (above 1 kHz) where the vibration energy is transmitted through the bearing housing to the machine casing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is mounting torque so important for this M8 stud?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHigh-frequency vibration monitoring relies on a perfect mechanical bond. If the M8 stud is under-torqued, the sensor may \"bounce\" or resonate at lower frequencies, creating false data. Over-torquing can damage the internal piezoelectric crystals or strip the metric threads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this sensor compatible with 3500\/42M monitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 330425 is standardly used with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/42M Proximitor\/Seismic Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1900\/65A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandalone monitor. Ensure the monitor configuration is set to \"Accelerometer\" with the correct 25 mV\/g sensitivity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurface Preparation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe mounting surface must be flat, smooth, and clean. Even minor imperfections or paint layers between the M8 stud and the machine casing can act as a dampener, filtering out the high-frequency signals you are trying to measure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling and Connectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccelerometers are sensitive to cable noise. Always use the recommended Bently Nevada shielded cables (like the 330400 series cables) and ensure the top-exit connector is tight and moisture-sealed using a silicone boot or heat-shrink if exposed to fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrientation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccelerometers are directional. Ensure the axis of the sensor is aligned with the direction of the vibration you wish to measure (typically radial or axial relative to the shaft).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf your monitoring system requires \"Velocity\" data but you are using this 330425 \"Acceleration\" sensor, the monitor must perform a mathematical integration (\u003cspan class=\"math-inline\"\u003eV=fadt\u003c\/span\u003e). Ensure this is correctly configured in the rack software to avoid incorrect unit displays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324577643,"sku":"330425-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330425-02-cn-accelerometeracceleration-transducers-n1zrypuzwvq_0a081b22-0eea-4982-a7cc-f2538f07e608.jpg?v=1765444446"},{"product_id":"bently-nevada-accelerometer-acceleration-transducer-model-330425-01-cn","title":"Bently Nevada Accelerometer Acceleration Transducer | Model 330425-01-CN","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330425-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Bently Nevada is a high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAccelerometer Acceleration Transducer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for accurate vibration and acceleration measurement in industrial machinery. Its rugged construction ensures consistent performance in demanding environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIdeal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbines, compressors, and pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotors and high-speed rotating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial condition monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications requiring precise vibration or acceleration data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe sensor provides reliable signal output for predictive maintenance and machinery protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e¼-28 UNF integral stud for easy mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh sensitivity: 2.5 mV\/m\/s² (25 mV\/g) ±5%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcellent amplitude linearity: ±1% up to 735 m\/s² (75 g) peak\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight, compact design (0.1 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN-specific agency approvals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMade in the USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAccelerometer Acceleration Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330425-01-CN\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e¼-28 UNF integral stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCN-specific approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e2.5 mV\/m\/s² (25 mV\/g) ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude Linearity\u003c\/td\u003e\n\u003ctd\u003e±1% to 735 m\/s² (75 g) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Application\u003c\/td\u003e\n\u003ctd\u003eVibration and acceleration monitoring in turbines, pumps, and motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325953899,"sku":"330425-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330425-01-cn-kjrabcdyy3x_5c784d0e-ea36-421a-a797-9e115dad58d0.jpg?v=1765521314"},{"product_id":"bently-nevada-200155-02-cn-accelerometer-for-machinery-condition-monitoring","title":"Bently Nevada 200155-02-CN Accelerometer for Machinery Condition Monitoring","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 200155-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaccelerometer is engineered for precise machinery condition monitoring. Designed and manufactured in the U.S.A, it provides reliable vibration measurement for predictive maintenance and industrial equipment health monitoring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting stud: 3\/8-24 to 3\/8-24 UNF, 1-3\/8 inch hex plate stud (\u003cstrong\u003eOption 02\u003c\/strong\u003e) for secure installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry-specific agency approval (\u003cstrong\u003eCN\u003c\/strong\u003e) with reference documentation available.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight design for easy integration; shipping weight: 2 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for monitoring turbines, pumps, compressors, and other rotating machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e200155-02-CN\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAccelerometer for Machinery Condition Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Stud\u003c\/td\u003e\n\u003ctd\u003e02 - 3\/8-24 to 3\/8-24 UNF, 1-3\/8 inch hex plate stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCN - Country-specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMade in\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSupports condition monitoring of critical rotating machinery. Provides accurate vibration data for predictive maintenance programs, helping to prevent unplanned downtime.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose This Accelerometer\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200155-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaccelerometer offers reliable, high-precision vibration monitoring with easy installation and long-term stability, making it ideal for industrial predictive maintenance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668326412651,"sku":"200155-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/200155-02-cn-kjhwrh1eoy0_cb9cd951-fac5-43cb-848f-36b3d382d93f.jpg?v=1765521332"},{"product_id":"bently-nevada-9571-60-low-cost-cable-for-accelerometer-60-ft","title":"Bently Nevada 9571-60 Low-Cost Cable for Accelerometer – 60 ft","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9571-60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLow-Cost Cable for Accelerometer from Bently Nevada is designed to offer reliable and cost-effective signal transmission for industrial accelerometer systems. With a length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e60 feet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(1828.8 cm), this cable provides the flexibility needed for a wide range of installations in vibration monitoring applications. Manufactured in the U.S.A., it ensures dependable performance in critical machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e60 ft\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(1828.8 cm) length for versatile installations in machinery monitoring setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCost-effective solution for connecting accelerometers to monitoring systems without compromising on performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt to meet the demands of vibration and condition monitoring applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufactured with quality materials to ensure durability and reliability over time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for use in industrial environments such as power plants, manufacturing, and oil \u0026amp; gas facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9571-60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable is perfect for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting accelerometers to vibration monitoring systems in industrial machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCost-effective replacements or installations in vibration-based condition monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse in a wide range of industries, including energy, manufacturing, and process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9571-60\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-Cost Cable for Accelerometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ft (1828.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Manufacture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668327330155,"sku":"9571-60","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9571-60-wgmfsfb4oe5_442b938b-c790-4715-9883-a279ff010560.jpg?v=1765521372"},{"product_id":"bently-nevada-330500-01-04-velomitor-piezo-velocity-sensor-1","title":"Bently Nevada 330500-01-04 Velomitor Piezo-Velocity Sensor","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330500-01-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVelomitor sensor from Bently Nevada is a precision piezo-velocity transducer designed to capture low-frequency vibration signatures in rotating equipment. Part of the 330500 series, it delivers stable velocity measurements used for machinery protection, performance trending, and fault diagnostics. Its rugged construction and wide agency approvals make it suitable for harsh industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePiezo-velocity sensing element optimized for reliable low-frequency vibration response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1\/2-20 UNF mounting thread adaptor (\u003cstrong\u003e01\u003c\/strong\u003e) for easy installation on standard brackets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGlobal certification package (\u003cstrong\u003e04\u003c\/strong\u003e) covering CSA, ATEX, and Brazil approvals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust housing for long-term operation in high-vibration areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConsistent output characteristics compatible with Bently Nevada monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSuitable for a range of industrial uses, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVelocity vibration monitoring on motors, gearboxes, pumps, and compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition-based maintenance strategies where consistent velocity data is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration into Bently Nevada monitoring platforms for real-time diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM installations and field retrofits requiring certified velocity transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330500-01-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e330500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-Velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread Option\u003c\/td\u003e\n\u003ctd\u003e01 = 1\/2-20 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003e04 = Multiple approvals (CSA, ATEX, Brazil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Weight\u003c\/td\u003e\n\u003ctd\u003e142 g (5.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668327461227,"sku":"330500-01-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330500-01-04-rb0qov0e4yh_72b4d113-ae0f-44f7-8679-ff635f8277c3.jpg?v=1765521377"},{"product_id":"bently-nevada-accelerometer-standard-cable-200152-15-10","title":"Bently Nevada Accelerometer Standard Cable | 200152-15-10","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200152-15-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada standard accelerometer cable designed for reliable vibration signal transmission. This model features a connector on the accelerometer end only and provides a 15-meter cable for flexible installation in industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003eIts robust construction ensures consistent performance in machinery monitoring applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e200152-15-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAccelerometer Standard Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eOn accelerometer end only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e15 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling Nut\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668327559531,"sku":"200152-15-10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/200152-15-10-ypf2pt1ddaw_d11aa015-8667-4438-bb7f-e1a18ebc92df.jpg?v=1765521381"},{"product_id":"bently-nevada-9571-20-low-cost-accelerometer-cable","title":"Bently Nevada 9571-20 Low Cost Accelerometer Cable","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe 9571-20 is a low cost cable designed for accelerometer signal transmission in machinery monitoring systems. It provides reliable connectivity between accelerometers and monitoring equipment. Moreover, it supports stable performance in industrial condition monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLow cost cable for accelerometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e9571-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin (COO)\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e20 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Application\u003c\/td\u003e\n\u003ctd\u003eAccelerometer signal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Configuration\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade signal cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Time\u003c\/td\u003e\n\u003ctd\u003e10–12 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAccelerometer signal transmission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery vibration monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial equipment diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668329918827,"sku":"9571-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9571-20-jwt2vskftej_ace732d9-b742-4b4c-9a88-c785fec4b466.jpg?v=1765521405"},{"product_id":"bently-nevada-9200-10-01-10-00-two-wire-transducer","title":"Bently Nevada 9200-10-01-10-00 Two-wire Transducer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe 9200-10-01-10-00 is a two-wire transducer designed for continuous vibration and condition monitoring. It supports stable signal transmission using a simple two-wire configuration. Moreover, it is suitable for permanent installation in industrial machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e9200-10-01-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin (COO)\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Configuration\u003c\/td\u003e\n\u003ctd\u003eTwo-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Angle \/ Min Operating Frequency\u003c\/td\u003e\n\u003ctd\u003eOption 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Option\u003c\/td\u003e\n\u003ctd\u003e01 = Top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base Option\u003c\/td\u003e\n\u003ctd\u003e10 = Circular base, M10 × 1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00 = No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Configuration\u003c\/td\u003e\n\u003ctd\u003eStud-mounted transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePermanent installation on rotating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial asset protection applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668329984363,"sku":"9200-10-01-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-10-01-10-00-ow5ndtwc2ed_67e75373-b998-4e38-a061-173aebb38270.jpg?v=1765521408"},{"product_id":"bently-nevada-330500-02-04-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-02-04 Velomitor Piezo-Velocity Sensor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330500-02-04 Velomitor Piezo-Velocity Sensor is designed for precise vibration velocity measurement in rotating machinery. Moreover, it supports continuous condition monitoring in industrial environments requiring stable and repeatable signals. Therefore, it is commonly used for machinery protection, diagnostics, and predictive maintenance systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e330500-02-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-Velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Configuration\u003c\/td\u003e\n\u003ctd\u003ePiezoelectric velocity transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread Adapter\u003c\/td\u003e\n\u003ctd\u003eM8 × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable and Connector\u003c\/td\u003e\n\u003ctd\u003eIntegrated sensor output, system-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX (Multiple Approvals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAdditional notes\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThis model has been replaced by 330500-02-CN Piezo-Velocity Sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical and mechanical form factor remain compatible for system replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial rotating machinery vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotors, pumps, compressors, and fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTurbines and balance-of-plant equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring and machinery protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668330606955,"sku":"330500-02-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330500-02-04-w3jg5rexev2_55d6059c-730e-4559-bb71-5f741b532cac.jpg?v=1765521432"},{"product_id":"bently-nevada-330400-01-05-accelerometer-api-670-compliant-vibration-sensor","title":"Bently Nevada 330400-01-05 Accelerometer | API 670 Compliant Vibration Sensor","description":"\u003ch3 class=\"\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330400-01-05 (330400)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision piezoelectric accelerometer engineered specifically for critical machinery protection and condition monitoring.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs a core component of the Bently Nevada vibration monitoring suite,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis sensor is designed to meet the rigorous American Petroleum Institute (API) Standard 670 requirements.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt delivers a linear output of 100 mV\/g,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it ideal for detecting high-frequency vibration characteristics in rotating equipment such as gas turbines,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecompressors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand pumps.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Performance and Accuracy\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis transducer offers an expansive frequency response range from 10 Hz to 15 kHz,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring comprehensive coverage of mechanical health indicators.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330400-01-05\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaintains exceptional amplitude linearity of ±1% up to a 50 g peak range.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWith a mounted resonant frequency exceeding 30 kHz,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe sensor minimizes signal distortion at high speeds,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhile the case-isolated design prevents ground loop interference in complex industrial electrical environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eRugged Industrial Construction\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eEncapsulated in a hermetically sealed 316L stainless steel housing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330400-01-05\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis built for extreme reliability.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt features an IP68 equivalent rating,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding total protection against dust and moisture ingress.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe unit operates reliably in temperatures ranging from -55°C to +121°C,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it suitable for both cryogenic and high-heat industrial processes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specific configuration includes a 1\/4-28 UNF integral mounting stud and carries comprehensive global hazardous area certifications (CSA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eATEX,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIECEx).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330400-01-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.2 mV\/m\/s² (100 mV\/g) ±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAcceleration Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e490 m\/s² (50 g) peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz to 15 kHz (±3dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResonant Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;30 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExcitation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 ± 0.5 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-55°C to +121°C (-67°F to +250°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e316L Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-pin MIL-C-5015 Receptacle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4-28 UNF integral stud\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple Approvals (ATEX, IECEx, CSA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330400 (330400-01-05)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the industry standard for vibration monitoring in the oil and gas, power generation, and petrochemical sectors. It is primarily utilized for monitoring rolling-element bearings, gear teeth mesh frequencies, and other machine components where high-frequency acceleration data is essential for early fault detection and preventing catastrophic equipment failure.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668338176363,"sku":"330400-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330400-01-05-xadkyrc5zly_8e3bafdc-e411-4f2a-b331-8087bac9a87f.jpg?v=1765521483"}],"url":"https:\/\/www.plcprotech.com\/collections\/bently-nevada-velocity-sensors-accelerometers.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}