{"title":"Cables","description":"\u003cp\u003eIndustrial Cables are engineered to maintain signal integrity and power distribution across complex automation networks. The architecture involves high-purity conductors, multi-layer shielding to mitigate EMI\/RFI, and durable outer jackets resistant to chemicals and abrasion. Technical characteristics include low capacitance for high-speed data transmission and standardized connectors for seamless integration with \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/i-o-modules\"\u003eI\/O modules\u003c\/a\u003e and \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/hmi-panels\"\u003eHMI panels\u003c\/a\u003e. Functionally, these cables provide the physical link for both analog signals and digital protocols, ensuring that critical data from \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/probes\"\u003eprobes\u003c\/a\u003e and sensors reaches the controller without attenuation or noise interference, thereby maintaining the accuracy of the entire control loop.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-330930-065-01-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-01-05 3300 NSv Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rugged, high-precision proximity transducer link engineered for the industry-leading\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 NSv\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity transducer system. Functioning as a high-integrity signal transmission path, this armored coaxial extension cable connects the specialized NSv proximity probe to the matching Proximitor sensor unit. Extreme operational environments—including oil and gas refineries, petrochemical processing plants, and critical aeroderivative gas turbine installations—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto deliver high-fidelity eddy current telemetry. The module maintains stable impedance profiles when routed through harsh confined spaces to track tight machinery clearances and small-shaft vibrations. By safeguarding low-voltage displacement signals from external radio frequency interference (RFI) and mechanical crushing, this cable guarantees precise data delivery. This continuous monitoring enables safety platforms to stop assets before catastrophic shaft misalignment or bearing wipe happens, effectively eliminating unprogrammed facility downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe ordering structure of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefines its exact mechanical shielding, transmission distance, and hazardous area safety compliance through a fixed modification format:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330930 (Base Model):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the 3300 NSv Coaxial Extension Cable platform tailored for narrow-gap and small-target proximity applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e065 (Cable Length Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfirms an exact physical cable length of 6.5 meters (21.3 feet), calibrated to specific electrical capacitance limits required by the driver module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01 (Connector Protector and Cable Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies an integrated flexible AISI 302 stainless steel armor sleeve outfitted with a high-durability Fluorinated Ethylene Propylene (FEP) outer jacket for maximum chemical and abrasion protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Agency Approval Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishes Multiple Approvals certification, qualifying the assembly for installation within explosive atmospheres and hazardous zones under ATEX and North American standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Benchmarks\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cstrong\u003eHardware Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cstrong\u003eCertified Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e330930-065-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e3300 NSv Proximity Transducer Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eComponent Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eArmored Coaxial Extension Cable with FEP Jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e6.5 meters (21.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eFlexible AISI 302 Stainless Steel (SST)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eOuter Insulation Jacket\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eFluorinated Ethylene Propylene (FEP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e0.220 Ohm\/meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCoaxial Shield Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e0.066 Ohm\/meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eNominal Cable Capacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e69.9 pF\/meter Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eMass Density (with Armor)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e64 g\/meter (0.7 oz\/foot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e-51 to +177 deg C Ambient Temperature Limits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eMinden, Nevada, USA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Telemetry \u0026amp; Mechanical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy must engineers select an exact cable length like the 6.5-meter option for proximity systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEddy current proximity transducer systems operate on strict total system electrical length calculations. The Proximitor sensor evaluates target distance by reading complex high-frequency impedance, which requires a fixed total capacitance. Modifying, cutting, or splicing the 330930-065-01-05 cable alters this baseline capacitance and corrupts the calibration curves, leading to invalid gap readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific protection does the 01 option provide over baseline unarmored coaxial cords?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 01 suffix configuration wraps the inner coaxial trace in flexible AISI 302 stainless steel armor, shielded further by a smooth FEP outer jacket. This setup prevents mechanical flattening or pinching from heavy cabinet doors and machine components while offering total chemical resistance against synthetic lubricants, hot oils, and corrosive industrial solvents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this extension cable maintain reliable telemetry under sub-zero or high-temperature steam environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The entire assembly utilizes advanced FEP insulation layers rated to maintain tight mechanical flexibility and zero dielectric breakdown across a wide operating thermal envelope of -51 to +177 deg C. This makes it highly stable for sub-sea cryogenic pumps as well as high-temperature gas turbine casing enclosures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection and Terminal Boot Alignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen joining the extension cable to the proximity probe lead, ensure the miniature coaxial connectors are clean, completely dry, and free of oily residues. Thread the connections together firmly by hand, avoiding excessive torque that can strip the micro-threads. Once joined, slide the factory connector protection sleeve or self-fusing silicone tape enclosure directly over the junction to seal it from moisture infiltration and prevent accidental grounding against nearby machine metalwork.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radii Rules and Conduit Routing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough the stainless steel armor casing provides excellent crushing protection, field technicians must adhere to standard minimum bend radius guidelines during routing. Avoid tight 90-degree creases or sharp structural edges that can kink the inner center conductor or alter the 69.9 pF\/meter nominal capacitance profile. Route the cable through dedicated, oil-tight flexible conduit paths, keeping the sensor wires separated from heavy high-voltage motor or generator supply lines to mitigate electro-magnetic cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Drainage and Structural Stress Relief:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen passing the 330930-065-01-05 cable through low-lying conduit runs, ensure the enclosure layout incorporates proper low-point drainage loops to prevent pooling fluid or condensation buildup from submerging the connections over long operating periods. Provide adequate strain relief loops at both the machine junction box and the 3500 rack entry plate, ensuring machine casing thermal expansion and high-frequency structural vibration do not pull or stress the cable terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515063147,"sku":"330930-065-01-05","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-01-05-nsv-extension-cable-phqpmgfntm3_c63fea36-3bf4-4a33-85bf-91600e72248c.jpg?v=1765440071"},{"product_id":"bently-nevada-330930-065-00-05-3300-xl-nsv-extension-cable","title":"Bently Nevada 330930-065-00-05 3300 XL NSv Extension Cable","description":"\u003ch3\u003e\n    Product Overview\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    The \u003cstrong\u003e330930-065-00-05 (3300 NSv)\u003c\/strong\u003e is a high-performance extension cable specifically engineered for the Bently Nevada 3300 XL NSv (Narrow Side View) Proximity Transducer System. This system is the industry standard for monitoring centrifugal air compressors, refrigeration compressors, and other rotating machinery with extremely tight installation constraints. As a critical link between the NSv probe and the Proximitor Sensor, the \u003cstrong\u003e330930-065-00-05\u003c\/strong\u003e ensures the transmission of high-fidelity displacement signals without impedance mismatch. Its 6.5-meter length is precisely tuned to provide the 200 mV\/mil (7.87 V\/mm) scale factor required for accurate radial vibration and axial position measurements on small-diameter shafts or targets.\n\u003c\/p\u003e\n\n\u003ch3\u003e\n    Suffix Configuration Breakdown\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    According to the official Datasheet 147385, the model \u003cstrong\u003e330930-065-00-05\u003c\/strong\u003e is defined by the following specific engineering options:\n\u003c\/p\u003e\n\n\u003cul class=\"list-paddingleft-2\"\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e065 (Cable Length):\u003c\/strong\u003e 6.5 meters (21.3 feet). This length is typically combined with a 0.5-meter probe to create a 7.0-meter total electrical system.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e00 (Connector Protector and Cable):\u003c\/strong\u003e Standard coaxial cable without stainless steel armor and without connector protectors. This version offers maximum flexibility for routing through dedicated conduit or internal machine housings.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e05 (Agency Approval):\u003c\/strong\u003e Multiple Approvals (ATEX, IECEx, CSA). This certification allows the cable to be used in intrinsically safe (I.S.) applications within hazardous areas globally.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\n    Technical Specifications\n\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003cthead\u003e\n        \u003ctr class=\"firstRow\"\u003e\n            \u003ctd\u003e\n                \u003cstrong\u003eAttribute\u003c\/strong\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n                \u003cstrong\u003eSpecification\u003c\/strong\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e330930-065-00-05\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eBently Nevada\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e3300 XL NSv Proximity Transducer\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eGold-plated Brass ClickLoc\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eJacket Material\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eFluorinated Ethylene Propylene (FEP)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e-52 deg C to +177 deg C (-62 deg F to +351 deg F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e-52 deg C to +177 deg C (-62 deg F to +351 deg F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\n    Engineering FAQs\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eWhy is the NSv extension cable different from standard 3300 XL cables?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    The NSv series is specifically designed for small targets and tight spaces. The electrical characteristics (inductance and capacitance) of the \u003cstrong\u003e330930\u003c\/strong\u003e cable are tuned to match the NSv probe's smaller coil. Mixing NSv cables with standard 8mm probes will result in incorrect vibration readings.\n\u003c\/p\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eWhat is the purpose of the ClickLoc connector?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    The ClickLoc connector is a patented design that prevents the connection between the probe and extension cable from loosening due to machinery vibration. The gold-plating ensures a low-resistance contact that is essential for maintaining the system's precision scale factor.\n\u003c\/p\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eCan I install this cable in an environment with turbine oil?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    Yes, the FEP jacket is highly resistant to turbine oil and most process chemicals. However, since this specific variant (\u003cstrong\u003e-00\u003c\/strong\u003e) does not have a connector protector, you must ensure the connection point is either sealed with the provided silicone tape or located in a dry area to prevent oil from entering the connector.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003e\n    Field Installation and Maintenance Directives\n\u003c\/h3\u003e\n\n\u003cul class=\"list-paddingleft-2\"\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eConnection Integrity:\u003c\/strong\u003e Before connecting the ClickLoc connectors, verify they are clean and dry. Use a lint-free cloth. Do not use pliers to tighten the connectors; they are designed to be finger-tightened until they \"click\" into a locked state.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eBend Radius Constraints:\u003c\/strong\u003e Maintain a minimum bend radius of \u003cstrong\u003e25.4 mm (1 inch)\u003c\/strong\u003e. Sharp bends can damage the internal coaxial shielding and dielectric, leading to \"signal spiking\" or a \"Not OK\" status on the 3500 monitor.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eProper Cable Support:\u003c\/strong\u003e Use high-quality cable ties or clamps to secure the cable every 1 to 2 feet. Ensure that the cable is not under tension at the connector ends. Vibration-induced stress on unsupported cables is a leading cause of premature failure in proximity systems.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eSystem Matching:\u003c\/strong\u003e Always verify that the total length of the probe plus the extension cable matches the configuration of the Proximitor Sensor (e.g., a 7m Proximitor requires a total cable length of 7m). The \u003cstrong\u003e330930-065\u003c\/strong\u003e is part of a 7.0-meter system when used with a 0.5-meter probe.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516275563,"sku":"330930-065-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-00-05-3300-xl-nsv-extension-cable-ullgkoscfm2_2e5685e9-33f6-4078-b646-4488fbee5f5e.jpg?v=1765440087"},{"product_id":"bently-nevada-9571-50-standard-interconnect-cable","title":"Bently Nevada 9571-50 Standard Interconnect Cable","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9571-50\u003c\/strong\u003e is a standard interconnect cable designed for use with industrial vibration monitoring and transducer systems. The cable assembly includes a moisture-resistant female connector at the transducer end and ring lugs at the monitor end for direct field wiring termination.\u003c\/p\u003e\n\u003cp\u003eThe cable uses shielded 0.382 mm2 (22 AWG) conductors to support stable signal transmission in electrically noisy industrial environments. The shielding construction assists with EMI\/RFI mitigation in machinery monitoring installations.\u003c\/p\u003e\n\u003cp\u003eThis interconnect cable is intended for connection between vibration transducers and monitoring equipment in rotating machinery applications including turbines, pumps, compressors, motors, and general condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe assembly supports installation in industrial environments requiring moisture resistance and extended operating temperature capability.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eShielded 0.382 mm2 (22 AWG) cable\u003c\/li\u003e\n\u003cli\u003eMoisture-resistant female connector\u003c\/li\u003e\n\u003cli\u003eRing lug termination at monitor end\u003c\/li\u003e\n\u003cli\u003eIndustrial transducer interconnect design\u003c\/li\u003e\n\u003cli\u003eEMI\/RFI shielding support\u003c\/li\u003e\n\u003cli\u003eFlexible field installation\u003c\/li\u003e\n\u003cli\u003eExtended temperature range\u003c\/li\u003e\n\u003cli\u003eCompatible with vibration monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVibration monitoring systems\u003c\/li\u003e\n\u003cli\u003eProximity transducer connections\u003c\/li\u003e\n\u003cli\u003eMachinery protection systems\u003c\/li\u003e\n\u003cli\u003eTurbine monitoring installations\u003c\/li\u003e\n\u003cli\u003eCompressor monitoring systems\u003c\/li\u003e\n\u003cli\u003eMotor condition monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating equipment\u003c\/li\u003e\n\u003cli\u003eProcess plant instrumentation\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance systems\u003c\/li\u003e\n\u003cli\u003ePermanent mounted monitoring installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e9571-AA: Standard Interconnect Cable\u003c\/li\u003e\n\u003cli\u003e-50: 50 ft (15.2 m) cable length option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eElectricalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eShielded cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eConductor Size\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eEnvironmentalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-29 to 121 degC (-20 to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMoisture Resistance\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eMoisture-resistant connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eMechanicalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eFemale connector at transducer end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMonitor End Termination\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eMinimum Length\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e2 ft (0.60 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMaximum Length\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eGeneralSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eStandard Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eTransducer Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eConnections\/Interfaces\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eConnector PinFunction\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eFemale Connector\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eTransducer connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eRing Lugs\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eMonitor termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cp\u003eRoute the cable separately from high-voltage motor wiring and variable frequency drive output cables to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eMaintain cable shielding continuity throughout the installation to support signal integrity.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive cable bending near the connector termination points during installation.\u003c\/p\u003e\n\u003cp\u003eSecure the cable properly to minimize vibration-related mechanical stress.\u003c\/p\u003e\n\u003cp\u003eVerify ring lug tightening torque during monitor termination work.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing surfaces before installation in moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eUse appropriate cable routing practices to prevent abrasion or pinch damage.\u003c\/p\u003e\n\u003cp\u003eAvoid extending the cable beyond the specified maximum length.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the conductor size of this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable uses 0.382 mm2 (22 AWG) conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of shielding is provided?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe assembly uses shielded cable construction for industrial signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat connector is installed at the transducer end?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA moisture-resistant female connector is installed at the transducer end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the monitor end terminated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor end uses ring lug terminations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum supported cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum specified length is 99 ft (30 m).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum available cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe minimum specified length is 2 ft (0.60 m).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the cable be used in industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The cable is intended for industrial vibration monitoring installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the cable support EMI\/RFI mitigation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shielded construction assists with EMI\/RFI reduction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat systems is the cable intended for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is intended for transducer and vibration monitoring system connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the cable be used outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe connector is moisture resistant, but installation suitability depends on enclosure and site conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat temperature range is supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified operating range is -29 to 121 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable suitable for permanent installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is suitable for permanently mounted machinery monitoring systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666624344427,"sku":"9571-50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-50-standard-interconnect-cable-tfd2n403jen_f9932837-544b-41d4-9e0b-edfee3645b51.jpg?v=1765444312"},{"product_id":"bently-nevada-89477-25-standard-armored-interconnect-cable","title":"Bently Nevada 89477-25 Standard Armored Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 89477-25\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003eStandard Armored Interconnect Cable\u003c\/strong\u003e designed specifically for critical machinery protection and condition monitoring systems. Engineered with a rugged right-angle connector interface, this cable provides reliable signal transmission between proximity probes, sensors, and monitoring modules within the \u003cstrong\u003eBently Nevada Proximitor Sensor Systems\u003c\/strong\u003e. The integrated armor casing ensures robust mechanical protection against physical damage, abrasion, and environmental hazards common in demanding industrial processing areas. By facilitating precise, low-attenuation signal delivery, it supports accurate vibration, position, and speed measurements for high-speed rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRight-angle connector configuration for low-profile installation in tight clearances\u003c\/li\u003e\n\u003cli\u003eIntegrated standard armor cladding for superior mechanical and environmental protection\u003c\/li\u003e\n\u003cli\u003ePre-cut length optimized to maintain signal integrity and calibration accuracy\u003c\/li\u003e\n\u003cli\u003eDurable construction resistant to industrial fluids, oils, and physical stress\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring systems\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating compressor diagnostics\u003c\/li\u003e\n\u003cli\u003eLarge industrial pumps, fans, and electric motor shaft displacement measurement\u003c\/li\u003e\n\u003cli\u003eHydroelectric generator air gap and vibration sensing setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight Angle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 Feet (approximately 7.6 Metres)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.15 kg (approximate based on standard armoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.6 Metres total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Maintenance\u003c\/strong\u003e: Avoid bending the armored section beyond the minimum specified bend radius to prevent damage to the internal conductors and armoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Routing\u003c\/strong\u003e: Ensure the right-angle connector is oriented properly before tightening to eliminate structural stress on the sensor connection point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Route the interconnect cable away from high-voltage conduits, variable frequency drives (VFDs), and alternating current (AC) power lines to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection\u003c\/strong\u003e: Ensure all connection interfaces are clean, dry, and properly sealed during installation to avoid moisture ingress and signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the right-angle connector on this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe right-angle design allows for secure connections in confined spaces where straight connectors would face excessive mechanical strain or clearance interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used with any proximity probe system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is specifically designed to integrate with compatible Bently Nevada proximity probe and Proximitor sensor systems matching the required connection footprint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the armoring protect against chemical exposure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard armor provides excellent mechanical protection against physical impacts and abrasion, while also offering resistance to common industrial oils and moisture under standard operating conditions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666733461867,"sku":"89477-25","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-89477-25-interconnect-cable-zyyj4ofhkb0_ee5e8dba-aa63-42b7-a111-1d4ccb7e7d30.jpg?v=1765446724"},{"product_id":"bently-nevada-9571-30-interconnect-cable","title":"Bently Nevada 9571-30 Standard Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9571-30\u003c\/strong\u003e is a heavy-duty, shielded \u003cstrong\u003einterconnect cable\u003c\/strong\u003e designed for critical machinery protection and vibration monitoring systems. It establishes a reliable signal transmission pathway between High Temperature Velocity Sensors (HTVS) and monitoring systems, ensuring the integrity of dynamic vibration data in harsh industrial environments. The cable features advanced shielding to minimize electromagnetic interference and a moisture-resistant termination to maintain electrical performance under demanding conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated moisture-resistant female connector at the HTVS termination point\u003c\/li\u003e\n\u003cli\u003ePre-terminated ring lugs at the monitor end for secure terminal block installation\u003c\/li\u003e\n\u003cli\u003eRobust shielding to protect low-level signals from EMI and RFI noise\u003c\/li\u003e\n\u003cli\u003eWide operating temperature rating for deployment in extreme industrial climates\u003c\/li\u003e\n\u003cli\u003eFlexible 22 AWG conductors optimizing signal conductivity and mechanical durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring\u003c\/li\u003e\n\u003cli\u003ePower generation facility machinery protection\u003c\/li\u003e\n\u003cli\u003ePetrochemical plant rotating equipment diagnostics\u003c\/li\u003e\n\u003cli\u003eHigh-temperature industrial fan and blower monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9571-AA\u003c\/td\u003e\n\u003ctd\u003eStandard Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-30\u003c\/td\u003e\n\u003ctd\u003e30 Feet = 9.0 Metres (approx.) length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9571-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eStandard Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eShielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type A (HTVS End)\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type B (Monitor End)\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 degC (-20 to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e30 Feet (approx. 9.0 Metres)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eAvailable upon request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e30 Feet length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection:\u003c\/strong\u003e Ensure the moisture-resistant female connector is fully seated and sealed at the HTVS end to prevent water ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the cable through dedicated conduit or cable trays away from high-voltage AC power lines to mitigate EMI\/RFI noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain the minimum recommended bend radius during installation to prevent damage to the internal 22 AWG conductors and shielding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Connect the cable shield in accordance with the specific monitoring system diagram, typically grounding at the monitor end only to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connections:\u003c\/strong\u003e Secure the pre-terminated ring lugs firmly to the monitor terminal blocks to ensure a vibration-proof electrical connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of sensor connects to the 9571-30 cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is specifically configured to interface with High Temperature Velocity Sensors (HTVS) on one end and standard machinery monitoring systems on the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this interconnect cable withstand outdoor industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the cable construction incorporates a moisture-resistant female connector and a rugged outer jacket rated for temperatures up to 121 degC, making it suitable for demanding industrial deployments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the shield terminated on this specific cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor end is fitted with ring lugs which accommodate standard grounding practices on monitor terminal strips, while the sensor end features a specialized shielded interface within the female connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to obtain this cable in lengths other than 30 feet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNon-standard and custom lengths can be ordered from the manufacturer using the 9571-AA configuration logic at additional cost.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666733691243,"sku":"9571-30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-30-interconnect-cable-yfe2hoqlxvu_60641b4b-4792-470b-853b-c190d2b0a9ca.jpg?v=1765446728"},{"product_id":"bently-nevada-89477-33-two-conductor-twisted-shielded-cable-assembly","title":"Bently Nevada 89477-33 Two-Conductor Twisted Shielded Cable Assembly","description":"\u003cp\u003eThe \u003cstrong\u003e89477\u003c\/strong\u003e cable family, specific part number \u003cstrong\u003e89477-33\u003c\/strong\u003e, is a high-integrity signal transmission assembly consisting of a two-conductor 18 AWG twisted, shielded cable engineered for critical rotor dynamics vibration monitoring. The physical design features a molded right-angle two-socket electrical plug at the transducer termination end to provide a compact, low-profile connection within tight mechanical spaces, while the monitoring system termination end is fitted with standard terminal lugs for direct interface with I\/O chassis blocks. Optimized for low attenuation and high electromagnetic noise immunity, this 10.0 m (33 ft) cable assembly forms an essential signal pathway connecting Bently Nevada machinery protection monitors to structural vibration sensors, including those installed inside a 21128 Velocity Transducer Housing, ensuring accurate transmission of dynamic AC voltage signals without phase distortion or external environmental interference.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-33: Cable Length Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e33 ft (10.0 m) nominal cable length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-conductor twisted pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall braided or foil shield with drain wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector End A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight-angle, two-socket plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector End B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.0 m (33 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Assembly Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 m (2.0 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Assembly Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 m (99 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada machinery monitors and 21128 Velocity Transducer Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe twisted-pair geometry explicitly minimizes differential-mode noise induction, which is critical for preserving low-voltage AC velocity or acceleration signals across long processing runs.\u003c\/li\u003e\n\u003cli\u003eThe right-angle two-socket plug enforces a fixed mechanical orientation, reducing physical strain on the transducer connector pin assembly inside protective housing units.\u003c\/li\u003e\n\u003cli\u003eCalculated electrical properties of the 18 AWG conductors dictate specific capacitance limits per foot; ensure overall loop length calculations fall within monitoring rack input impedance specifications to prevent high-frequency signal roll-off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExecute correct shield grounding by connecting the cable shield drain wire exclusively to the instrument rack chassis ground, leaving the transducer end completely ungrounded to isolate against ground loops.\u003c\/li\u003e\n\u003cli\u003eAvoid routing this twisted, shielded signal cable parallel to high-voltage AC three-phase motor lines or heavy switching inductive loads to preserve data integrity and prevent noise injection.\u003c\/li\u003e\n\u003cli\u003eObserve standard industrial minimum bend radius constraints during conduit installation to protect the internal 18 AWG conductors and shield layering from mechanical shear stress.\u003c\/li\u003e\n\u003cli\u003eEnsure the right-angle plug is fully seated and threaded tight into the transducer body interface to maintain environmental sealing and prevent terminal contact resistance changes under heavy vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666747847019,"sku":"89477-33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-89477-33-interconnect-cable-fnplq2c02nm_b64e1700-c17b-4343-8e55-7643c49ed096.jpg?v=1765446979"},{"product_id":"bently-nevada-16710-33-interconnect-cable-with-armor","title":"Bently Nevada 16710-33 Interconnect Cable with Armor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-33\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterconnect cable with armor from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis designed for secure signal transmission in machinery protection and vibration monitoring systems operating in harsh industrial environments. It is widely deployed in turbines, compressors, pumps, generators, and large rotating equipment installed in refinery, petrochemical, offshore, and power generation facilities where mechanical stress, oil exposure, and continuous vibration are present.\u003c\/p\u003e\n\u003cp\u003eThis armored interconnect cable provides reinforced mechanical protection for signal wiring used between proximity probes, proximitor modules, junction boxes, and monitoring systems. The 33 ft length supports flexible installation in medium-range equipment layouts while maintaining stable signal integrity in electrically noisy environments. The armored construction reduces the risk of abrasion, crushing, and mechanical fatigue, ensuring long service life in demanding industrial installations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 16710 series uses an armored cable structure designed to improve mechanical durability and environmental resistance in field installations.\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e16710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength Option\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial protective armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eInterconnect signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery protection systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Environment\u003c\/td\u003e\n\u003ctd\u003eHigh vibration, oil exposure, industrial plants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe armored layer provides mechanical shielding against external impact and cable wear, making it suitable for routing in areas with moving machinery, sharp structural edges, and high vibration loads. It is engineered to maintain consistent electrical performance while reducing signal degradation caused by mechanical stress.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16710-33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable with Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C (typical industrial cable range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring and machinery protection systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main purpose of armored construction in this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe armor provides mechanical protection against abrasion, crushing, and external impact in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the 16710-33 cable typically used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is used in machinery monitoring systems connecting probes, modules, and junction boxes in rotating equipment installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high vibration areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The armored design is specifically intended for high vibration industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable electrically active?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. It is a passive interconnect cable used for signal transmission only.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Engineering Recommendations\u003c\/h3\u003e\n\u003cp\u003eInstall the cable with proper strain relief to prevent mechanical stress transfer into connector termination points.\u003c\/p\u003e\n\u003cp\u003eAvoid routing near high-voltage power cables or VFD output lines to reduce electromagnetic interference in signal transmission.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius during installation to preserve conductor integrity under continuous vibration conditions.\u003c\/p\u003e\n\u003cp\u003eSecure armored sections using industrial cable clamps to ensure stable positioning in moving or high-vibration machinery areas.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666760528235,"sku":"16710-33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-33-interconnect-cable-3s1vfoeywic_fb947b41-3b19-4835-8272-260ec1e3ba41.jpg?v=1765447126"},{"product_id":"bently-nevada-9571-10-two-conductor-twisted-shielded-interconnect-cable","title":"Bently Nevada 9571-10 Two-Conductor Twisted Shielded Interconnect Cable","description":"\u003cp\u003eThe \u003cstrong\u003e9571\u003c\/strong\u003e instrumentation interconnect cable, complete part number \u003cstrong\u003e9571-10\u003c\/strong\u003e, is a high-performance two-conductor 22 AWG shielded cable assembly designed for transmitting dynamic vibration signals within machinery protection systems. The physical construction features a moisture-resistant two-socket female connector at the sensor termination end to maintain electrical insulation in humid environments, while the monitor termination end is fitted with standard terminal lugs for robust installation into I\/O chassis backplanes. This 10 ft (3.05 m) twisted-pair configuration provides superior differential noise rejection, ensuring precise signal transmission from compatible transducers directly to Bently Nevada machinery monitors. This cable is explicitly not designed for integration within the 21128 Velocity Transducer Housing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10: Cable Length Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e10 ft (3.05 m) nominal cable length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwisted, shielded pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-socket moisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.05 m (10 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 m (2.0 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 m (99 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Constraints\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot for use with 21128 Velocity Transducer Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 22 AWG twisted-pair geometry provides high noise immunity against electro-magnetic interference by canceling out differential-mode noise along the signal pathway.\u003c\/li\u003e\n\u003cli\u003eThe sensor-end termination utilizes a specialized moisture-resistant compound within the 2-socket female connector housing to prevent moisture ingress from degrading insulation resistance.\u003c\/li\u003e\n\u003cli\u003eTotal loop resistance and cable capacitance scale linearly with length; ensure overall parameters align with monitoring system input barriers to maintain accurate high-frequency data transfer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the cable shield drain wire exclusively to the instrument rack instrumentation ground bar, and completely isolate the shield at the transducer end to prevent structural ground loops.\u003c\/li\u003e\n\u003cli\u003eRoute the signal cable away from high-voltage AC electric motor supply cables, variable frequency drives (VFDs), and heavy inductive switching elements to maintain raw signal integrity.\u003c\/li\u003e\n\u003cli\u003eAdhere strictly to industrial minimum bending radius standards during conduit routing to prevent physical degradation of the internal shield foil and 22 AWG copper strands.\u003c\/li\u003e\n\u003cli\u003eEnsure the moisture-resistant connector is fully locked and sealed against the sensor body to guarantee long-term environmental protection and reliable contact interface.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666765181291,"sku":"9571-10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-10-interconnect-cable-xuptdzcpsz4_41f1678f-55d2-4cbd-834c-67e79130ed61.jpg?v=1765447211"},{"product_id":"bently-nevada-84661-82-standard-armored-interconnect-cable","title":"Bently Nevada 84661-82 Standard Armored Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 84661-82\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003eStandard Armored Interconnect Cable\u003c\/strong\u003e designed for critical signal transmission in industrial machinery protection and vibration monitoring systems. It features a rugged stainless steel armor wrapped over a shielded 0.382 mm2 (22 AWG) conductor core, providing excellent mechanical protection against physical damage and environmental hazards. The assembly is built with a moisture-resistant female connector at the High Temperature Velocity Sensor (HTVS) end and ring lugs at the monitor terminal end, ensuring secure, low-loss connectivity to continuous monitoring modules. Engineered to operate reliably across a temperature range of -29 to 121 Celsius, this cable is highly optimized for deployment with high-reliability sensors in harsh industrial monitoring environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel outer armoring for superior crush and abrasion resistance\u003c\/li\u003e\n\u003cli\u003eMoisture-resistant female terminal connector configured for HTVS applications\u003c\/li\u003e\n\u003cli\u003ePre-terminated ring lugs at the monitor interface for secure terminal block connection\u003c\/li\u003e\n\u003cli\u003eShielded 22 AWG core construction to minimize electrical noise and signal attenuation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring loops\u003c\/li\u003e\n\u003cli\u003eIndustrial compressor and expander casing velocity measurements\u003c\/li\u003e\n\u003cli\u003eHeavy-duty pump and fan vibration telemetry\u003c\/li\u003e\n\u003cli\u003eHigh-temperature processing areas requiring ruggedized physical cable shielding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.382 mm2 (22 AWG), shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor End Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector (HTVS end)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 Celsius (-20 to 250 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 Feet (approx. 24.6 Metres)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Ensure the shield drain wire or shielded component is correctly referenced to the designated monitor ground terminal to prevent ground loops and mitigate EMI\/RFI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Constraints\u003c\/strong\u003e: Do not force sharp bends or kinks in the stainless steel armoring during routing, as this can pinch internal conductors and rupture the protective shield.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection\u003c\/strong\u003e: Verify that the moisture-resistant female connector interface is fully seated and properly sealed at the HTVS end to prevent fluid ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Keep the path of the interconnect cable separate from high-voltage motor lines or switching control wires to protect the accuracy of low-level analog signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat sensor types link with this specific cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable is constructed with a moisture-resistant female terminal configuration explicitly intended for connection to High Temperature Velocity Sensors (HTVS) on the machine end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the monitor end interface connect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor end uses pre-installed ring lugs, which allow for a secure, bolt-down termination onto standard terminal blocks inside monitor enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the armored jacket withstand high-temperature processing zones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the components of this assembly are rated to sustain continuous exposure to industrial environments with ambient operational temperatures ranging from -29 to 121 Celsius.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666768195947,"sku":"84661-82","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-84661-82-velomitor-interconnect-cable-ohizj0hpw1b_1972d5ed-07ac-44bf-b813-1668d8ec3403.jpg?v=1765447242"},{"product_id":"honeywell-51109693-100b-universal-control-network-ucn-4-port-drop-cable-tap-ground-module","title":"Honeywell 51109693-100B Universal Control Network (UCN) 4-Port Drop Cable Tap Ground Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51109693-100B\u003c\/strong\u003e is a specialized network interface components designed for the Universal Control Network (UCN) within legacy TotalPlant Solution (TPS) and TDC 3000 Distributed Control Systems (DCS). This module serves as a ruggedized \u003cstrong\u003e4-port drop cable tap ground block\u003c\/strong\u003e, facilitating secure coax interface coupling and precise grounding infrastructure for critical high-speed control data lines.\u003c\/p\u003e\n\u003cp\u003eEngineered strictly for harsh industrial control environments, the \u003cstrong\u003e51109693-100B\u003c\/strong\u003e establishes robust branch connections from the primary UCN trunk line to individual nodes such as High-Performance Process Managers (HPM), Network Interface Modules (NIM), or Advanced Process Managers (APM). By providing high-integrity shielding terminations and static discharge paths, the module actively prevents common-mode noise propagation, ground-loop disruptions, and signal attenuation along the network segment. Its industrial-grade passive architecture ensures uninterrupted physical layer operations and uniform impedance matching necessary for continuous multi-node industrial process synchronization.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures an integrated \u003cstrong\u003e4-port drop cable connection\u003c\/strong\u003e infrastructure enabling dual or multi-node transceiver drops from a localized point.\u003c\/li\u003e\n\u003cli\u003eIncorporates a dedicated low-resistance grounding bus bar interface to drain induced EMI\/RFI interference away from coax cores.\u003c\/li\u003e\n\u003cli\u003eMaintains strict physical layer attenuation parameters to ensure signal integrity across extended TDC 3000 network topologies.\u003c\/li\u003e\n\u003cli\u003eDesigned with heavy-duty cast aluminum or specialized shielding material to shield inner high-frequency junctions from ambient industrial noise.\u003c\/li\u003e\n\u003cli\u003eEmploys tight-tolerance BNC or specialized coax termination mechanisms minimizing insertion losses and reflection coefficients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control System (DCS) physical layer installation in petrochemical plants and oil refineries running Honeywell TDC 3000 \/ TPS platforms.\u003c\/li\u003e\n\u003cli\u003eSpecialized grounding and drop distribution for high-reliability communications between HPM subsystems and Network Interface Modules (NIM).\u003c\/li\u003e\n\u003cli\u003ePower generation utility networks requiring isolated and noise-immune fieldbus topologies across long physical distances.\u003c\/li\u003e\n\u003cli\u003ePulp, paper, and heavy manufacturing processing lines utilizing legacy coaxial-based corporate process control infrastructures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51109693-100B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternative Part Identifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51201395-100 Kit Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Control Network (UCN) Drop Cable Tap Ground Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Port Distribution \/ Drop Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoaxial Cable Trunk Line Drop Tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.0 cm x 9.8 cm x 4.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-density shielded industrial enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrunk In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrimary Coaxial UCN Cable Input Segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrunk Out\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous Primary Coaxial UCN Cable Output Continuation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Port 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNode Branch Drop Line Connection 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Port 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNode Branch Drop Line Connection 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Port 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNode Branch Drop Line Connection 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Port 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNode Branch Drop Line Connection 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGND Stud\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain Earth Reference Low-Impedance Grounding Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements\u003c\/strong\u003e: Secure the main external ground lug directly to the local instrumentation clean ground bus bar via a low-impedance braided copper strap. Avoid chaining ground paths across multiple separate mechanical frames.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and EMI Isolation\u003c\/strong\u003e: Ensure complete coaxial outer shield continuity through the terminal clamps to prevent RF leakage and high-frequency common-mode industrial noise entry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing Precautions\u003c\/strong\u003e: Route incoming and outgoing trunk cables through dedicated low-voltage data conduits, maintaining a minimum 300mm clearance from high-voltage AC supply lines or variable frequency drive outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop Cable Bend Radius\u003c\/strong\u003e: Adhere strictly to the OEM coax specifications regarding minimum bend radii during installation inside local field marshaling panels to prevent structural dielectric deformation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core function of the 51109693-100B within a Honeywell DCS network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module acts as a localized 4-port drop junction and signal grounding block on the Universal Control Network, linking primary coax trunks to node transceivers without degrading impedance characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require external active power loops to run?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this is an entirely passive mechanical and electrical interface unit designed for signal division, impedance maintenance, and grounding mitigation across coaxial lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan unused drop ports be left open during active system runtime?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, all unused drop terminals on active network lines should be fitted with compatible high-frequency impedance terminators to avoid signal reflections and potential frame corruption errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting orientation is ideal for maximizing environmental resilience?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module should be mounted inside a dust-proof NEMA\/IP-rated control enclosure, preferably with the drop connectors facing downwards to avoid moisture ingress or debris accumulation within the female barrels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667749532011,"sku":"51109693-100B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-51109693-100b-bracket-un3vk2whkyz_3aa2fb77-65e2-41d3-9b7d-adeb1d10bc9a.jpg?v=1765501531"},{"product_id":"bently-nevada-cb2w100-064-interconnect-cable","title":"Bently Nevada CB2W100-064 Interconnect Cable","description":"\u003ch3\u003eTechnical Summary\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada CB2W100-064 is a 64 feet (19.5 meters) interconnect cable engineered for transmitting dynamic vibration and acceleration signals within machinery protection systems. It establishes a secure, low-noise signal path between industrial transducers and monitoring mainframes, minimizing electromagnetic interference (EMI) and preventing signal attenuation or false trips. The cable utilizes a twisted-pair architecture with a dedicated shield to maintain signal integrity over long-distance runs in harsh electromagnetic environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB2W100\u003c\/strong\u003e: Product series designation for premium, high-temperature dynamic signal interconnect cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-064\u003c\/strong\u003e: Specifies the exact physical length of the cable assemble, designated as 64 feet (equivalent to 19.5 meters).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors\u003c\/strong\u003e: Features a MIL-C 5015 standard 2-socket connector at the sensor end with splash-proof isolation, transitioning to a blunt-cut termination at the monitor\/junction box end.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductors\u003c\/strong\u003e: 20 AWG twisted pair copper conductors optimized for low electrical resistance and high tensile strength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding\u003c\/strong\u003e: Integrated braided or foil shield providing continuous coverage against radio frequency and electrostatic noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJacket Material\u003c\/strong\u003e: High-durability yellow Teflon (FEP) insulation offering superior chemical resistance and thermal stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCB2W100-064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eCable Length\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e64 feet (19.5 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eConductor Gauge\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e20 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eTwisted pair, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eConnector A\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eMIL-C 5015, 2 Socket, Premium, Splash Proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eConnector B\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eBlunt cut \/ Flying leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eJacket Material\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eYellow Teflon (FEP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e-55 to +200 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eCore Application\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eTransducer-to-rack analog signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How should the shield wire of the CB2W100-064 be terminated to avoid ground loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shield must be grounded at one single point, typically at the monitor rack or structural ground inside the junction box. Leave the shield floating and isolated at the transducer end using the premium isolated MIL-C 5015 connector housing to prevent circulating ground currents from corrupting the vibration signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this cable be used with proximity probe systems or is it strictly for accelerometers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis 2-socket MIL-C 5015 configuration is primarily designed for 2-wire accelerometers and velocity sensors. Standard proximity probes require 3-wire extension cables (such as the 3300 XL series). Verify transducer pinning before deployment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum temperature rating for the yellow Teflon jacket?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Teflon (FEP) jacket is rated for continuous operation from -55 to +200 deg C, making it suitable for routing near hot casing surfaces on steam turbines, gas turbines, and compressors.\u003c\/p\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMaintain a minimum bend radius of 75 mm during installation to prevent internal conductor fatigue or damage to the Teflon insulation layer.\u003c\/li\u003e\n\u003cli\u003eRoute the cable through dedicated, grounded metal conduit when deploying across open structural spans to provide mechanical protection and secondary EMI shielding.\u003c\/li\u003e\n\u003cli\u003eSecure the MIL-C 5015 threaded connector to the sensor housing using a calibrated torque wrench, ensuring the splash-proof seal is fully compressed without over-tightening.\u003c\/li\u003e\n\u003cli\u003eKeep the interconnect cable isolated from high-voltage AC power lines by a minimum clearance of 300 mm to eliminate cross-talk and induction noise on the low-voltage AC\/DC vibration signal.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668291383659,"sku":"CB2W100-064","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cb2w100-064-vsz41w0zaev_fe968a98-9d74-40cc-88e5-e1f3d7075186.jpg?v=1765520349"},{"product_id":"bently-nevada-106765-04-interconnect-cable-1","title":"Bently Nevada 106765-04 Interconnect Cable","description":"\u003ch3\u003eTechnical Summary\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e106765-04\u003c\/strong\u003e is a 4-meter interconnect cable engineered for transmitting dynamic eddy current sensor signals within the 3300 Proximity Transducer System. It establishes a dedicated electrical pathway linking the Proximitor Sensor to the 3300 rack monitor. The hardware minimizes signal attenuation and impedance mismatch, preventing RF reflections and phase shifts across the 24.3 mV\/um or 7.87 V\/mm scale factor. This shielding architecture blocks electromagnetic interference (EMI) to isolate critical vibration frequencies, eliminating reading drift and preventing false machine trips during high-frequency rotor dynamics tracking.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e106765\u003c\/strong\u003e - Base model identifier for high-performance coaxial interconnect cables optimized for Bently Nevada proximity systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04\u003c\/strong\u003e - Defines the specific physical length configuration representing 4.0 meters (13.1 feet) of overall cable length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e106765-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCoaxial, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003ePhysical Length\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e3300 Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e4.0 meters (length) x 3.2 mm (diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003ePassive device (0.0 mW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eImpedance\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e75.0 ohms nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eConnector Material\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eGold-plated brass (ClickLoc style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e Can the 106765-04 cable be modified or spliced in the field if the length is excessive?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Splicing or cutting this coaxial cable alters the total system capacitance and electrical length, which destroys the calibrated 7.87 V\/mm (200 mV\/mil) scale factor. Excess length must be looped and secured, not removed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e Is the 106765-04 directly compatible with the newer 3300 XL series Proximitor sensors?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It interfaces physically with 3300 XL hardware, but using the non-XL 106765 cable with an XL Proximitor limits system performance to legacy 3300 standards and may introduce minor linearity discrepancies. Use 3300 XL series extensions for full XL specs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What occurs if the coaxial connectors encounter moisture or oil contamination inside a conduit?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Liquid ingress causes cross-talk or insulation breakdown, shifting the gap voltage reading toward zero VDC and generating false probe fault alerts. Seal connections with silicone tape or fluid-tight terminal boxes.\u003c\/p\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm during installation. Avoid sharp bends or kinks that displace the internal dielectric layer and degrade signal propagation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Circuitry:\u003c\/strong\u003e Terminate the outer shield braid strictly at the monitor rack chassis ground. Leave the field sensor end floating inside an isolated terminal block to prevent ground loops that superimpose 50\/60 Hz noise onto the vibration signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Torque:\u003c\/strong\u003e Hand-tighten the coaxial connectors until the internal lock clicks. Apply a single drop of non-conductive thread-locking compound if operating under extreme structural vibration profiles; do not use pliers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Verification:\u003c\/strong\u003e Post-installation, verify the static gap voltage measures between -9.0 VDC and -11.0 VDC (nominal target -10.0 VDC) using a digital multimeter at the terminal block to confirm correct electrical length match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668291416427,"sku":"106765-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/106765-04-cldsrqajcgv_54326de0-3c18-4910-a66f-d540f4974baa.jpg?v=1765520350"},{"product_id":"bently-nevada-cb2w100-112-interconnect-cable","title":"Bently Nevada CB2W100-112 Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCB2W100-112\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterconnect cable from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis designed for long-distance signal transmission within industrial machinery protection and vibration monitoring systems. This cable is commonly installed between proximity probes, monitoring modules, junction boxes, and condition monitoring equipment used on steam turbines, centrifugal compressors, generators, pumps, and large rotating machinery operating in refinery, petrochemical, mining, and power generation facilities.\u003c\/p\u003e\n\u003cp\u003eThe 112 ft cable length supports extended routing requirements inside large process plants where monitoring cabinets are positioned far from rotating assets. Bently Nevada designs the CB2W100 series for stable signal integrity in electrically noisy industrial environments exposed to vibration, oil contamination, heat, and continuous mechanical operation. The cable construction supports reliable communication between field transducers and monitoring systems, helping maintenance teams maintain accurate machinery condition data and reduce unplanned shutdown events caused by signal instability or wiring failures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCB2W100\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e112\u003c\/td\u003e\n\u003ctd\u003e112 ft cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetric Length Equivalent\u003c\/td\u003e\n\u003ctd\u003e34.1 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCable Design and Application Details\u003c\/h3\u003e\n\u003cp\u003eThe CB2W100 series is engineered for industrial machinery monitoring installations requiring stable low-noise signal transmission over extended cable distances. The cable supports integration with Bently Nevada vibration monitoring systems commonly installed on API rotating equipment.\u003c\/p\u003e\n\u003cp\u003eIts industrial-grade construction helps resist environmental stress caused by continuous machine vibration, oil exposure, and elevated ambient temperatures commonly found in turbine halls and compressor stations. The long cable length allows flexible routing between field instrumentation and centralized monitoring cabinets without requiring additional intermediate connections.\u003c\/p\u003e\n\u003cp\u003eThe cable is widely used in condition monitoring applications where maintaining signal reliability remains critical for predictive maintenance and machinery protection performance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCB2W100-112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e112 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Metric\u003c\/td\u003e\n\u003ctd\u003e34.1 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery protection and vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Area\u003c\/td\u003e\n\u003ctd\u003eTurbines, compressors, motors, generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eSuitable for industrial process environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Routing\u003c\/td\u003e\n\u003ctd\u003eLong-distance industrial signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary use of the CB2W100-112 cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable is used for signal transmission between field transducers and Bently Nevada machinery monitoring systems installed on rotating equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be installed in refinery and power plant environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The cable is designed for industrial environments with vibration, heat, and continuous machinery operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the total cable length of this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis version provides a total cable length of 112 ft, equivalent to approximately 34.1 metres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the CB2W100-112 suitable for long cable routing applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The extended cable length supports installations where monitoring cabinets are located far from machinery assets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines and Field Recommendations\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from high-voltage motor conductors and VFD output wiring to minimize electromagnetic interference within machinery monitoring circuits.\u003c\/p\u003e\n\u003cp\u003eUse vibration-resistant cable clamps when installing near turbines, compressors, or large motors. Unsupported cable sections may experience long-term mechanical fatigue under continuous vibration conditions.\u003c\/p\u003e\n\u003cp\u003eInspect cable routing paths for sharp metal edges and excessive heat exposure before commissioning. Continuous abrasion or thermal stress may reduce cable service life in industrial process environments.\u003c\/p\u003e\n\u003cp\u003eFor outdoor installations, use sealed conduit systems and industrial-grade cable protection methods to prevent moisture intrusion and environmental contamination.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668300525931,"sku":"CB2W100-112","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CB2W100-112-4ygb2clpbnh_3367adcb-ed88-4a38-b1b8-adeb828f4be5.jpg?v=1765520524"},{"product_id":"288055-01-bently-nevada-standard-transient-data-interface-module-with-usb-cable","title":"288055-01 | Bently Nevada | Standard Transient Data Interface Module with USB cable","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e288055-01 \u003c\/strong\u003eis a 3500\/22M TDI module designed for precise condition monitoring.\u003cbr\u003eIt provides the interface between the 3500 rack and monitoring software.\u003cbr\u003eThe module integrates high-bandwidth communication processing for reliable data capture.\u003cbr\u003eIt supports static, transient, and high-resolution waveform data across all channels.\u003c\/p\u003e\n\u003ch3\u003eCore Identification\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e288055-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eStandard Transient Data Interface (TDI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3500\/22M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Slot\u003c\/td\u003e\n\u003ctd\u003eSlot 1 in 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommunication \u0026amp; Interfaces\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eFront panel USB Type-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Version\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eLocal configuration and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Communication\u003c\/td\u003e\n\u003ctd\u003eRequires compatible rear I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003e3500 proprietary rack interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eData Acquisition Capabilities\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Types\u003c\/td\u003e\n\u003ctd\u003eStatic, transient, high-resolution waveforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Mode\u003c\/td\u003e\n\u003ctd\u003eContinuous, multi-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eProcesses synchronous and asynchronous data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Storage\u003c\/td\u003e\n\u003ctd\u003eNon-volatile flash memory for configuration and event logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical \u0026amp; Shipping\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e5.0 kg (includes packaging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003eFactory-sealed, ESD-safe materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eUSB configuration cable, quick start manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch4\u003eFront-Panel USB Access\u003c\/h4\u003e\n\u003cp\u003eTechnicians connect laptops directly to the front USB port.\u003cbr\u003eRear cabinet access is not required for configuration or diagnostics.\u003c\/p\u003e\n\u003ch4\u003eHigh-Fidelity Data Streaming\u003c\/h4\u003e\n\u003cp\u003eWaveform data streams across all channels simultaneously.\u003cbr\u003eThis ensures no data loss during critical machine events.\u003c\/p\u003e\n\u003ch4\u003eTransient Data Capture\u003c\/h4\u003e\n\u003cp\u003eCaptures machine behavior during startup and coast-down.\u003cbr\u003eHelps identify resonance, rotor rubs, and bearing instability.\u003c\/p\u003e\n\u003ch4\u003eIndustrial Reliability\u003c\/h4\u003e\n\u003cp\u003eAdvanced shielding protects against electromagnetic interference.\u003cbr\u003eThe module maintains signal integrity in harsh industrial environments.\u003c\/p\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Type\u003c\/td\u003e\n\u003ctd\u003e3500\/05 or 3500\/06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot\u003c\/td\u003e\n\u003ctd\u003eSlot 1 (TDI slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003e3500 Rack Configuration Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring System\u003c\/td\u003e\n\u003ctd\u003eSystem 1 (Version 6.x or later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired I\/O Module\u003c\/td\u003e\n\u003ctd\u003eRear I\/O module, e.g., 146031-01 for Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ (Frequently Asked Questions)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 288055-01 a replacement for 138607-01?\u003c\/strong\u003e\u003cbr\u003eYes. It fits the same rack slot and offers improved performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a rear I\/O module?\u003c\/strong\u003e\u003cbr\u003eYes. Ethernet or network communication requires a compatible rear module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat data does the 288055-01 collect?\u003c\/strong\u003e\u003cbr\u003eIt collects static, transient, and high-resolution waveform data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this module installed?\u003c\/strong\u003e\u003cbr\u003eIt installs in Slot 1 of the 3500\/05 or 3500\/06 rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I verify authenticity?\u003c\/strong\u003e\u003cbr\u003eEach unit is factory-sealed with a “Made in U.S.A.” label.\u003cbr\u003eThe serial number can be verified against Bently Nevada records.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668302983531,"sku":"288055-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/288055-01-0fuojr4ph0r_75cbce1a-4770-493c-b79c-4ef3895afba2.jpg?v=1765520601"},{"product_id":"330930-065-00-cn-bently-nevada-3300-nsv-extension-cable","title":"330930-065-00-CN | Bently Nevada | 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3300 NSv Extension Cable\u003c\/strong\u003e provides vital electrical connection and signal path routing within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This specialized coaxial line interfaces between a non-contacting \u003cstrong\u003e3300 NSv\u003c\/strong\u003e proximity probe and its matching \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e to accurately relay eddy-current displacement signals. The \u003cstrong\u003e3300 XL NSv\u003c\/strong\u003e system is specifically intended for compact machinery applications, including centrifugal process air compressors, refrigeration compressors, and high-density installations exhibiting narrow side-view or counterbore clearances where standard systems face space constraints.\u003c\/p\u003e\n\u003cp\u003eThis specific product number \u003cstrong\u003e330930-065-00-CN\u003c\/strong\u003e designates a 6.5-metre layout variant built without defensive stainless steel armor plating, featuring hazardous area certification compliant with specialized regulatory standards for the China regional market. To maintain robust signal path integrity without physical shifting, the hardware features integrated gold-plated brass \u003cstrong\u003eClickLoc\u003c\/strong\u003e coaxial connectors on both terminal points that click-lock securely to prevent connections from loosening under sustained machine resonance. Utilizing a tailored 75-ohm impedance profile coupled with fluoroethylene propylene insulation, this component acts as a highly stable data transmission channel for precise mechanical vibration loops within safety and critical asset-monitoring infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Coaxial Connectors:\u003c\/strong\u003e Uses premium gold-plated brass hardware that positive-locks into place, ensuring continuous contact and preventing separation in high-vibration fields.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Grade FEP Insulation:\u003c\/strong\u003e Formulated with fluoroethylene propylene shielding to provide superior chemical and thermal resilience within challenging industrial oil and gas environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched System Impedance:\u003c\/strong\u003e Features an engineered 75-ohm characteristic design that matches the baseline requirements of the proximity probe to protect signal linearity across the loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Temperature Stability:\u003c\/strong\u003e Rated to withstand demanding environmental swings without altering electrical capacitance or inducing scale-factor drifts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors, process gas machinery, and refrigeration compression units.\u003c\/li\u003e\n\u003cli\u003eHigh-density rotating machinery instrumentation featuring tight physical constraints or narrow shaft targets smaller than 51 mm.\u003c\/li\u003e\n\u003cli\u003eMachinery monitoring networks measuring radial vibration, axial thrust positioning, or zero-speed tachometer inputs within hazardous industrial zones requiring localized country-specific compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330930\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-065\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Length Option: 6.5 metres (21.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector and Cable Option: Without stainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: Approvals country specific (China Approvals covering CCC\/NEPSI requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtension Cable Impedance\u003c\/td\u003e\n\u003ctd\u003e75 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCenter Conductor DC Resistance\u003c\/td\u003e\n\u003ctd\u003e0.220 ohms\/m (0.067 ohms\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eShield DC Resistance\u003c\/td\u003e\n\u003ctd\u003e0.066 ohms\/m (0.020 ohms\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +177 Celsius (-60 Fahrenheit to +351 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +177 Celsius (-60 Fahrenheit to +351 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtension Cable Material\u003c\/td\u003e\n\u003ctd\u003eCoaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eConnector Material\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eClickLoc miniature coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e6.5 metres (21.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Rated Tensile Strength\u003c\/td\u003e\n\u003ctd\u003e220 N (50 lb) at lead-to-extension cable connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCable Weight (Typical)\u003c\/td\u003e\n\u003ctd\u003e45 g\/m (0.5 oz\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Length Matching:\u003c\/strong\u003e Ensure that the combined physical length of your chosen extension cable and proximity probe equals the pre-calibrated baseline of the associated Proximitor Sensor (typically 5 or 7 meters total system length).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Care and Protection:\u003c\/strong\u003e Keep the miniature ClickLoc terminals clear of grease, solvents, and ambient dust before clicking them shut. It is recommended to apply a connector protector or wrap the joint in specialized silicone tape to block industrial moisture entry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid Turbine Oil Submersion:\u003c\/strong\u003e Do not deploy standard silicone-taped connections in internal machinery zones where the junctions are continuously exposed to moving turbine lubricating fluids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Constraints:\u003c\/strong\u003e Maintain a clean routing path that adheres strictly to the minimum bend constraint of 25.4 mm to prevent kinks, shielding cracks, or conductor attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing Separation:\u003c\/strong\u003e Separate the sensor signal line from adjacent high-voltage or variable-frequency drive power conduits to minimize stray electromagnetic or electrostatic background noise cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Authorized under option code -CN to cover specialized NEPSI\/CCC requirements for installation in hazardous industrial zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e Incorporates underlying ATEX\/IECEx hazardous area markings and rating frameworks on the product nameplate as applicable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the -CN suffix indicate for this proximity extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -CN suffix indicates a specialized regional approval variant tailored for the China market. It ensures compliance with mandatory CCC and NEPSI hazardous area safety standards while maintaining core alignment with international ATEX\/IECEx parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unarmored cable version be substituted directly into a layout requiring stainless steel armor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe underlying electrical properties are identical, but this model lacks the physical armor spiral shroud. If your application paths leave the cable bare to falling debris or sharp metal edges, an armored variant or a standalone protective conduit path is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the combined length of my probe and extension cable exceeds the calibrated sensor specification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsing unmatched total system lengths will alter the baseline electrical capacitance and inductance properties of the instrumentation loop. This skews the Average Scale Factor, leading to inaccurate machine displacement and vibration readings.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308554091,"sku":"330930-065-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-065-00-CN-eogtlymqjy4_3c3a5929-1782-4ede-90cf-27f4c6f5cbc8.jpg?v=1765520759"},{"product_id":"bently-nevada-3300-xl-series-21747-045-01-proximitor-extension-cable-with-armor","title":"Bently Nevada 3300 XL Series 21747-045-01 Proximitor Extension Cable with Armor","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e21747-045-01 (21747-045-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical link within the Bently Nevada 3300 and 3300 XL Proximitor Sensor systems. This specific extension cable is engineered to maintain high-fidelity signal transmission between the proximity probe and the Proximitor sensor, ensuring precise vibration and position monitoring in demanding rotating machinery environments. The inclusion of stainless steel armor provides superior mechanical protection against physical abrasion and fluid exposure common in industrial settings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e21747-045-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 Meters (Approximately 14.8 Feet \/ 177 Inches)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlexible Stainless Steel Armor (Option 01)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 and 3300 XL 5mm \u0026amp; 8mm Proximity Transducer Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial Gold-plated ClickLoc connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 °C to +177 °C (-60 °F to +350 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProper implementation of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e21747-045-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires ensuring that the combined length of the proximity probe and the extension cable matches the required system length of the Proximitor Sensor (typically 5.0 or 9.0 meters). This armored version is ideal for internal machine housing or exposed conduit runs where moisture, oil, or mechanical impact risks are present.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used with non-XL 3300 sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e21747-045-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis backward compatible with standard 3300 series 5mm and 8mm systems, provided the total electrical length is calibrated correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the '01' Armor option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stainless steel braiding prevents the coaxial core from being crushed or kinked, which would otherwise alter the electrical capacitance and degrade the accuracy of vibration data.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668310094187,"sku":"21747-045-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/21747-045-01-fsoxkziulth_7260c2c9-8728-4dd8-a6f7-5f900ae6824f.jpg?v=1765520819"},{"product_id":"bently-nevada-cb2w100-32-interconnect-cable","title":"Bently Nevada CB2W100-32 Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCB2W100-32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterconnect cable from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis designed for industrial vibration monitoring and machinery protection systems operating in demanding process environments. This cable assembly uses MIL-C 5015 splash-proof connectors with a 2-socket configuration and supports reliable signal transmission between proximity probes, monitoring modules, and field instrumentation installed on turbines, compressors, pumps, and large rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThe cable features 20 AWG twisted pair conductors with shielding and a yellow Teflon jacket engineered for high-temperature industrial applications where oil exposure, vibration, and electromagnetic interference are common. Bently Nevada includes the locking ring, adapter seal, and O-ring to improve environmental sealing and connector stability during long-term field operation. The 32 ft cable length supports flexible routing inside turbine enclosures, compressor skids, motor control areas, and refinery monitoring cabinets while maintaining stable signal integrity across critical machinery protection circuits.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCB2W100\u003c\/td\u003e\n\u003ctd\u003eMIL-C 5015 splash-proof interconnect cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e32 ft cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Metric Equivalent\u003c\/td\u003e\n\u003ctd\u003e9.75 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCable Construction and Connector Design\u003c\/h3\u003e\n\u003cp\u003eThe CB2W100 series uses twisted pair shielded conductors to reduce electrical noise interference in high-electromagnetic industrial environments. The yellow Teflon cable jacket provides improved resistance against heat, oil contamination, abrasion, and chemical exposure commonly found near rotating equipment installations.\u003c\/p\u003e\n\u003cp\u003eThe cable assembly includes MIL-C 5015 2-socket connectors with splash-proof construction for industrial field reliability. The isolated blunt-cut termination configuration simplifies custom field integration into monitoring cabinets and junction assemblies. Included locking hardware improves connector retention under continuous machine vibration conditions.\u003c\/p\u003e\n\u003cp\u003eThis cable is commonly deployed within Bently Nevada machinery protection systems used in refinery process trains, power generation equipment, LNG facilities, and offshore rotating machinery installations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCB2W100-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMIL-C 5015, 2 Socket, Splash-Proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e20 AWG twisted pair, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003eYellow Teflon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eIsolated to blunt cut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd\u003eLocking ring, adapter seal, O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e32 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Metric\u003c\/td\u003e\n\u003ctd\u003e9.75 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eSuitable for industrial high-temperature environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery protection and vibration monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat monitoring systems use the CB2W100-32 cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable is commonly used with Bently Nevada vibration monitoring systems, proximity probe installations, and rotating machinery protection applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the cable include field installation hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The assembly includes a locking ring, adapter seal, and O-ring for improved connector sealing and retention.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of shielding does this cable use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable uses twisted pair shielded conductors to reduce electromagnetic interference in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable operate near turbines and compressors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The Teflon jacket and industrial connector design support installation in high-temperature and high-vibration machinery areas.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines and Engineering Recommendations\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from high-voltage motor power wiring and VFD output cables to minimize electrical noise interference within machinery protection circuits.\u003c\/p\u003e\n\u003cp\u003eDuring installation, avoid excessive cable bending near connector termination points. Tight bending radius conditions may reduce long-term conductor reliability in continuous vibration environments.\u003c\/p\u003e\n\u003cp\u003eInspect locking ring engagement and sealing components before startup in outdoor or washdown process areas. Improper connector sealing may allow moisture intrusion into monitoring circuits.\u003c\/p\u003e\n\u003cp\u003eFor turbine and compressor installations, secure the cable using vibration-resistant clamps to prevent connector loosening during long-term machine operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668310585707,"sku":"CB2W100-32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cb2w100-32-1n0g3cvnptc_00d564cc-d6fe-4cb2-9979-b9f237130c7a.jpg?v=1765520839"},{"product_id":"bently-nevada-03818100-heavy-duty-cable-fitting","title":"Bently Nevada 03818100 Heavy Duty Cable Fitting","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e03818100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eheavy duty cable fitting from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a conduit termination component designed for secure and environmentally sealed cable entry in industrial proximity transducer and machinery protection systems. It is commonly applied in turbine monitoring assemblies, compressor skids, pump systems, and heavy rotating equipment installations where mechanical vibration, oil exposure, and harsh environmental conditions require robust cable sealing and strain relief.\u003c\/p\u003e\n\u003cp\u003eThis fitting is engineered in AISI 316 stainless steel and uses a 3\/4-14 NPT thread interface to ensure mechanical integrity and corrosion resistance in refinery, petrochemical, offshore, and power generation environments. It is typically used in PROXPAC proximity transducer assemblies and similar monitoring configurations where reliable conduit sealing is required to maintain signal stability and protect instrumentation wiring from environmental ingress. The design supports long-term installation stability under continuous vibration and thermal cycling conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 03818100 fitting is a standalone mechanical interface component designed for industrial conduit termination.\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eAISI 316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eHeavy duty conduit cable fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Role\u003c\/td\u003e\n\u003ctd\u003eCable entry sealing and strain relief\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eProximity transducer assemblies (including PROXPAC systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Resistance\u003c\/td\u003e\n\u003ctd\u003eCorrosion, vibration, industrial fluids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe structure provides mechanical locking between conduit and enclosure entry points, ensuring cable stability and reducing stress transmission to sensitive proximity measurement wiring. The stainless steel body ensures long-term resistance to chloride exposure and refinery-grade corrosive atmospheres.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e03818100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox 0.4 kg (typical stainless fitting class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT interface standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C (industrial environment range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive mechanical component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eAISI 316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCable conduit termination, proximity systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs 03818100 an electrical component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. It is a mechanical cable fitting used for conduit sealing and cable entry protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this fitting typically installed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is installed at enclosure entry points in proximity transducer systems and industrial monitoring assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this compatible with PROXPAC systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is commonly used in PROXPAC proximity transducer assemblies for sealed cable routing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used in corrosive environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. AISI 316 stainless steel provides high resistance to corrosion in offshore and refinery conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct 3\/4-14 NPT thread engagement during installation to achieve full mechanical sealing and prevent conduit loosening under vibration conditions.\u003c\/p\u003e\n\u003cp\u003eApply proper torque during tightening to avoid thread deformation while maintaining sealing integrity in high-vibration machinery environments.\u003c\/p\u003e\n\u003cp\u003eUse compatible sealing compounds when required by site specification to improve ingress protection in humid or washdown areas.\u003c\/p\u003e\n\u003cp\u003eRoute cables with adequate bend radius after the fitting to prevent mechanical stress transfer into sensitive proximity transducer wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318089579,"sku":"03818100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/03818100-0a4d4mealm3_e2af372c-c821-427f-bd33-24bf4855fe9d.jpg?v=1765521094"},{"product_id":"330877-080-36-cn-bently-nevada-3300-xl-50-mm-extension-cable","title":"330877-080-36-CN Bently Nevada 3300 XL 50 mm Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN (330877-080-36-CN)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 3300 XL 50 mm extension cable manufactured by Bently Nevada, specifically engineered for critical machinery protection and proximity sensor systems. As a vital component of the 3300 XL 50 mm Proximitor sensor system, this cable maintains signal integrity between the probe and the Proximitor sensor in large-scale rotating equipment. Featuring the specialized FluidLoc technology and PFA insulation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to prevent hazardous fluids from wicking through the cable, making it an essential solution for oil-filled environments such as turbines, compressors, and large industrial pumps in the oil and gas or power generation sectors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a 75 ohm triaxial architecture, insulated with perfluoroalkoxyethylene (PFA) to ensure extreme temperature resilience and chemical resistance. This specific configuration features a cable length of 8.0 meters (26.2 feet) and utilizes the \"36\" FluidLoc option, which provides an additional layer of protection against fluid migration—a common cause of sensor failure in pressurized machinery. The \"CN\" agency approval indicates country-specific compliance, ensuring the hardware meets rigorous safety and technical standards for localized industrial deployments. With a typical capacitance of 69.9 pF\/m, the cable is tuned to maintain the precise electrical characteristics required for accurate vibration and position measurements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330877-080-36-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 50 mm Extension Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 meters (26.2 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm triaxial, PFA insulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor\/Cable Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc technology (Option 36)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +200 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +200 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (Country Specific)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the FluidLoc (Option 36) cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc extension cable is specifically designed with a proprietary internal seal that prevents oil, moisture, or other process fluids from leaking through the inside of the cable. This protects the Proximitor sensor electronics from contamination if a probe seal fails in an oil-filled machine housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 330877-080-36-CN compatible with standard 3300 XL 8 mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This extension cable is specifically designed for the 3300 XL 50 mm system. The electrical characteristics (capacitance and impedance) of 50 mm cables differ from 8 mm or 11 mm systems. Using mismatched cables will result in significant calibration errors and inaccurate machinery vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable withstand extreme high-temperature environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Thanks to the PFA (perfluoroalkoxyethylene) insulation, the cable is rated for continuous operation in temperatures ranging from -51 Celsius to +200 Celsius, making it suitable for mounting inside hot turbine enclosures or near steam lines.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation, ensure the miniature coaxial connectors remain clean and dry. Use a silicone lubricant only on the connector threads if required by the manual, but never on the signal-carrying pins. It is highly recommended to use connector protectors or heat-shrink tubing to seal the connection point between the probe and the extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo avoid damaging the triaxial shielding and the FluidLoc seal, observe the minimum bend radius during routing. Avoid sharp 90-degree bends; instead, use sweeping curves to maintain the 75 ohm impedance and prevent signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRouting and Interference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough grounded metal conduit wherever possible. Avoid running the extension cable parallel to high-voltage AC motor leads or VFD cables, as electromagnetic interference (EMI) can introduce noise into the low-voltage proximity signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318679403,"sku":"330877-080-36-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330877-080-36-cn-aqxqi3pbqbs_b6b0a565-3d1e-4920-94a6-c1ddfde9ed58.jpg?v=1765521112"},{"product_id":"bently-nevada-89477-20-interconnect-cable-20-ft-industrial-signal-link","title":"Bently Nevada 89477-20 Interconnect Cable 20 ft Industrial Signal Link","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 89477-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an interconnect cable designed for vibration monitoring and machinery protection systems where stable signal transmission between field devices and monitoring modules is required. It is commonly used in turbines, compressors, pumps, and industrial rotating equipment across power generation and process industries.\u003c\/p\u003e\n\u003cp\u003eThis cable provides a direct electrical link between system components, ensuring reliable data transfer in environments with vibration, electrical noise, and continuous industrial operation. It supports consistent signal integrity for condition monitoring systems where measurement accuracy directly affects machine protection decisions.\u003c\/p\u003e\n\u003cp\u003eThe 20 ft length configuration supports flexible installation in control cabinets and field-mounted monitoring setups.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e89477\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20 ft cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis simplified configuration defines cable family type and physical length for system integration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e89477-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e20 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSignal transmission for monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Role\u003c\/td\u003e\n\u003ctd\u003eInterconnect between monitoring and field devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eIndustrial machinery monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is designed for stable low-noise signal transmission in industrial environments where electromagnetic interference and mechanical vibration are present.\u003c\/p\u003e\n\u003cp\u003eIt ensures consistent connectivity between monitoring modules and field instrumentation, supporting accurate vibration and condition monitoring data acquisition.\u003c\/p\u003e\n\u003cp\u003eThe cable structure is optimized for durability under continuous industrial operation conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbine systems, compressors, pumps, and industrial monitoring panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is its main function?\u003c\/strong\u003e\u003cbr\u003eIt provides electrical interconnection between monitoring system components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for industrial vibration and electrical noise conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect performance?\u003c\/strong\u003e\u003cbr\u003eWithin specified design limits, 20 ft supports stable signal transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eRoute cable away from high-voltage power lines to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bends to maintain conductor integrity and signal stability.\u003c\/p\u003e\n\u003cp\u003eEnsure connectors are fully seated to prevent intermittent signal loss.\u003c\/p\u003e\n\u003cp\u003eUse proper cable management to reduce vibration-induced mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper grounding practices to ensure signal stability in noisy environments.\u003c\/p\u003e\n\u003cp\u003eInspect connector interfaces during scheduled maintenance cycles.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical tension on cable ends during installation.\u003c\/p\u003e\n\u003cp\u003eUse standardized routing paths inside control panels to improve reliability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319007083,"sku":"89477-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/89477-20-3chmqkzrnkk_aeabdb4b-577f-4515-af7c-d9847d23c650.jpg?v=1765521126"},{"product_id":"bently-nevada-330190-045-00-00-3300-xl-extended-temperature-range-etr-extension-cable","title":"Bently Nevada 330190-045-00-00  | 3300 XL Extended Temperature Range (ETR) Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330190-045-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL Extended Temperature Range (ETR) extension cable designed for vibration monitoring systems operating in thermally demanding industrial environments. It is commonly used in turbines, compressors, and process machinery where stable signal transmission must be maintained under elevated temperature conditions.\u003c\/p\u003e\n\u003cp\u003eThis cable supports reliable data transfer between proximity probes and monitoring modules while minimizing signal drift caused by thermal stress. It is applied in power generation, oil and gas, and heavy industrial systems where temperature stability directly affects machine protection accuracy.\u003c\/p\u003e\n\u003cp\u003eThe 4.5 meter configuration provides flexible routing in compact and mid-range machinery installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330190\u003c\/td\u003e\n\u003ctd\u003e3300 XL ETR extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e045\u003c\/td\u003e\n\u003ctd\u003e4.5 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo additional cable option required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines cable length and configuration level within the ETR extension cable family.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-045-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended temperature range extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eTriaxial ETR design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eHigh temperature industrial systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ETR cable design maintains stable electrical characteristics under elevated temperature conditions where standard extension cables may experience signal drift or insulation degradation.\u003c\/p\u003e\n\u003cp\u003eTriaxial construction ensures low-noise signal transmission and stable impedance performance, which is critical for accurate vibration monitoring in rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThe cable is optimized for integration in high-temperature zones such as turbine casings and compressor housings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and high-temperature industrial machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of ETR design?\u003c\/strong\u003e\u003cbr\u003eIt ensures stable signal performance under elevated thermal conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates into the 3300 XL monitoring architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect performance?\u003c\/strong\u003e\u003cbr\u003eWithin specification, 4.5 m length maintains stable signal transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid routing near high-temperature steam lines exceeding rated limits.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-power electrical cables to reduce EMI interference.\u003c\/p\u003e\n\u003cp\u003eEnsure correct connector engagement to maintain signal stability.\u003c\/p\u003e\n\u003cp\u003eUse appropriate cable supports to prevent mechanical stress in high-vibration areas.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius to protect triaxial shielding integrity.\u003c\/p\u003e\n\u003cp\u003eInspect insulation condition during scheduled maintenance in high-heat environments.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shielding for optimal noise suppression.\u003c\/p\u003e\n\u003cp\u003eAvoid direct contact with hot surfaces or radiant heat sources.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319105387,"sku":"330190-045-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330190-045-00-00-extension-cable-vv44ifx1gve_81f44a4c-8bd7-4af8-8fdb-50fa958ad864.jpg?v=1765440498"},{"product_id":"bently-nevada-330730-080-13-cn-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-080-13-CN 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330730-080-13-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 11 mm extension cable designed for vibration monitoring systems used in heavy industrial rotating machinery. It is widely applied in turbines, compressors, and large motor-driven equipment in power plants, oil refineries, and mining operations.\u003c\/p\u003e\n\u003cp\u003eThis cable ensures stable signal transmission between 11 mm proximity probes and monitoring modules under high vibration and electrically noisy conditions. The armored FluidLoc construction improves mechanical protection and maintains signal integrity in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe 8.0 meter length supports flexible installation layouts in distributed monitoring architectures while maintaining consistent electrical performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330730\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable with connector protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach configuration element defines mechanical protection level, cable length, and compliance classification within the 3300 XL 11 mm system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330730-080-13-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e11 mm extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eConnector protectors included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL 11 mm series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 11 mm cable series is engineered for enhanced signal stability in large rotating machinery applications where longer cable runs and higher electromagnetic interference levels are present.\u003c\/p\u003e\n\u003cp\u003eArmored FluidLoc construction provides mechanical durability while maintaining low-noise electrical performance, reducing the risk of signal distortion caused by vibration or cable movement.\u003c\/p\u003e\n\u003cp\u003eConnector protectors improve long-term reliability by preventing contamination and mechanical wear at interface points.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and large industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored FluidLoc design?\u003c\/strong\u003e\u003cbr\u003eIt increases mechanical durability and improves signal reliability in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all 11 mm probes?\u003c\/strong\u003e\u003cbr\u003eIt is designed for Bently Nevada 3300 XL 11 mm proximity systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy are connector protectors important?\u003c\/strong\u003e\u003cbr\u003eThey reduce contamination and mechanical damage at connection interfaces.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid tight bending near connector ends to preserve signal stability.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-voltage cables and VFD systems to reduce interference.\u003c\/p\u003e\n\u003cp\u003eEnsure connector locking is fully engaged during installation.\u003c\/p\u003e\n\u003cp\u003eSecure cable routing to avoid vibration-induced mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse proper strain relief at both ends to avoid load transfer to connectors.\u003c\/p\u003e\n\u003cp\u003eInspect armor integrity during scheduled maintenance cycles.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius for armored cable sections.\u003c\/p\u003e\n\u003cp\u003eEnsure grounding continuity for shielding effectiveness in noisy environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319138155,"sku":"330730-080-13-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330730-080-13-cn-kzhtnrvtql2_2c22313d-9614-48ef-a61d-d34f6f313b5d.jpg?v=1765521131"},{"product_id":"bently-nevada-330190-080-00-cn-3300-xl-extended-temperature-range-etr-extension-cable","title":"Bently Nevada 330190-080-00-CN | 3300 XL Extended Temperature Range (ETR) Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330190-080-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL Extended Temperature Range (ETR) extension cable designed for vibration monitoring systems operating in elevated and thermally unstable industrial environments. It is applied in turbines, compressors, petrochemical units, and power generation systems where signal stability must be maintained under continuous thermal stress.\u003c\/p\u003e\n\u003cp\u003eThis cable supports reliable signal transmission between proximity probes and monitoring modules while maintaining electrical integrity across extended temperature conditions. It reduces measurement drift and protects machine protection systems from signal degradation in harsh operating zones.\u003c\/p\u003e\n\u003cp\u003eThe 8.0 meter configuration provides flexible installation for distributed monitoring layouts in large industrial machinery assemblies.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330190\u003c\/td\u003e\n\u003ctd\u003e3300 XL extended temperature range cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines mechanical configuration, electrical design standard, and compliance classification within the ETR extension cable family.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-080-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended temperature range extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, FEP insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Capability\u003c\/td\u003e\n\u003ctd\u003eExtended temperature design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ETR cable series is designed for environments where standard extension cables cannot maintain stable electrical characteristics under elevated temperatures.\u003c\/p\u003e\n\u003cp\u003eFluoroethylene propylene (FEP) insulation improves thermal resistance and chemical stability, making the cable suitable for oil, gas, and high-temperature industrial environments.\u003c\/p\u003e\n\u003cp\u003eTriaxial construction ensures low-noise signal transmission and stable impedance characteristics across long cable runs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and high-temperature industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes ETR cables different?\u003c\/strong\u003e\u003cbr\u003eThey maintain electrical stability under extended temperature conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is fully compatible with 3300 XL proximity measurement architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is triaxial construction important?\u003c\/strong\u003e\u003cbr\u003eIt reduces noise and improves signal stability in electrically harsh environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid routing near high-temperature steam lines or heat sources exceeding rated limits.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shielding to maintain signal integrity in noisy electrical environments.\u003c\/p\u003e\n\u003cp\u003eMaintain proper bend radius to avoid degradation of triaxial shielding structure.\u003c\/p\u003e\n\u003cp\u003eVerify connector seating before commissioning to ensure stable measurement output.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse thermal spacing in cable routing to avoid continuous exposure to radiant heat sources.\u003c\/p\u003e\n\u003cp\u003eEnsure proper strain relief at cabinet entry points to prevent mechanical stress transfer.\u003c\/p\u003e\n\u003cp\u003eInspect insulation condition periodically in high-temperature applications.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high-power electrical cables to minimize EMI interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319203691,"sku":"330190-080-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330190-080-00-cn-smlnidfadci_9cfde8bb-9bc1-4ff1-8ff6-c9d3ef82773c.jpg?v=1765521134"},{"product_id":"bently-nevada-330130-040-11-00-3300-xl-extension-cable","title":"Bently Nevada 330130-040-11-00 3300 XL Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330130-040-11-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL extension cable designed for reliable signal transmission in proximity measurement systems used for vibration and shaft position monitoring. It is commonly deployed in turbines, compressors, generators, and industrial rotating machinery where stable signal integrity directly impacts machine protection performance.\u003c\/p\u003e\n\u003cp\u003eThis cable supports armored FluidLoc construction, which improves resistance to mechanical damage, oil exposure, and harsh industrial handling conditions. It ensures stable electrical continuity between proximity probes and monitoring modules in high-vibration environments.\u003c\/p\u003e\n\u003cp\u003eThe 4.0 meter length configuration provides flexible installation in control cabinets and field-mounted monitoring systems while maintaining signal stability across extended routing paths.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConstruction \u0026amp; Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e040\u003c\/td\u003e\n\u003ctd\u003e4.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe configuration defines cable length, mechanical protection level, and compliance scope within the 3300 XL system architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-040-11-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eMechanical abrasion resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is engineered to maintain low-noise signal transmission between proximity probes and monitoring systems in high-vibration industrial environments.\u003c\/p\u003e\n\u003cp\u003eArmored FluidLoc construction provides enhanced mechanical durability, reducing risk of cable damage during installation and long-term operation in harsh machinery areas.\u003c\/p\u003e\n\u003cp\u003eThe shielding design ensures signal stability in electrically noisy environments such as turbine halls and compressor stations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in vibration monitoring systems for turbines, compressors, and industrial rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored FluidLoc design?\u003c\/strong\u003e\u003cbr\u003eIt improves mechanical protection and reduces signal disruption in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for Bently Nevada 3300 XL proximity measurement systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect signal quality?\u003c\/strong\u003e\u003cbr\u003eWithin system specifications, 4.0 m length maintains stable signal performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid sharp bending during installation to prevent damage to internal conductors and shielding.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-voltage and VFD cables to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eEnsure connectors are fully engaged and locked to prevent intermittent signal loss.\u003c\/p\u003e\n\u003cp\u003eSecure cable routing to avoid mechanical stress from vibration or movement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius for armored construction to prevent long-term fatigue.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief at connection points to protect connector integrity.\u003c\/p\u003e\n\u003cp\u003eInspect cable shielding continuity during commissioning for optimal signal performance.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of system shielding to minimize electrical noise interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319236459,"sku":"330130-040-11-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-040-11-00-extension-cable-qn2ay5mvagf_f310ea0b-ffcd-478a-8ed5-6392231e7e8a.jpg?v=1765440915"},{"product_id":"bently-nevada-84661-34-10-meter-velomitor-interconnect-cable","title":"Bently Nevada 84661-34 | 10 meter Velomitor Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 84661-34\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 10 meter Velomitor interconnect cable designed for reliable signal transmission between velocity transducers and vibration monitoring systems. It is used in industrial machinery protection systems across power generation, oil and gas, and process industries where stable vibration signal integrity is critical.\u003c\/p\u003e\n\u003cp\u003eThis cable assembly provides a rugged armored construction to protect signal transmission in high-vibration and harsh environmental conditions. It ensures consistent data transfer from HTVS velocity sensors to monitoring equipment without degradation caused by electrical noise or mechanical stress.\u003c\/p\u003e\n\u003cp\u003eThe stainless steel armor layer enhances mechanical durability, making it suitable for installations exposed to abrasion, moisture, and industrial handling stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConstruction \u0026amp; Design Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Core\u003c\/td\u003e\n\u003ctd\u003eShielded 22 AWG (0.382 mm2) conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eStainless steel protective layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor End\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector (HTVS side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor End\u003c\/td\u003e\n\u003ctd\u003eRing lug termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe structure is engineered to maintain signal integrity while providing mechanical protection in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e84661-34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eArmored interconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Connection\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Connection\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVelocity transducer signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is designed to maintain stable low-noise signal transmission between velocity sensors and monitoring systems in electrically and mechanically harsh environments.\u003c\/p\u003e\n\u003cp\u003eStainless steel armor protects the internal conductors from abrasion and mechanical damage during installation and long-term operation.\u003c\/p\u003e\n\u003cp\u003eShielded conductor design reduces electromagnetic interference, ensuring signal accuracy in environments with variable frequency drives and high-power electrical systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in power plants, refineries, and industrial machinery vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is armored cable important?\u003c\/strong\u003e\u003cbr\u003eIt protects signal integrity against mechanical damage and harsh industrial handling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with all Velomitor sensors?\u003c\/strong\u003e\u003cbr\u003eIt is designed for compatible Bently Nevada Velomitor and HTVS systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it reduce electrical noise?\u003c\/strong\u003e\u003cbr\u003eYes. Shielded construction helps minimize EMI interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid excessive bending during installation to prevent internal conductor stress.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shield layer to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eRoute cable away from high-voltage and VFD power lines for optimal signal integrity.\u003c\/p\u003e\n\u003cp\u003eSecure stainless steel armor properly at mounting points to prevent vibration-induced fatigue.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius to avoid long-term mechanical fatigue in armored structure.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing periodically in moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief at both ends to prevent mechanical load transfer to connectors.\u003c\/p\u003e\n\u003cp\u003eEnsure ring lug termination is firmly secured to monitoring system terminals for stable signal transmission.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319269227,"sku":"84661-34","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/84661-34-xineykv00ar_bd189d67-6de3-412b-8dbc-91f4c1b8515a.jpg?v=1765521137"},{"product_id":"bently-nevada-330130-075-01-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-01-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330130-075-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL standard extension cable designed for vibration monitoring signal transmission in turbines, compressors, generators, and refinery rotating machinery. It connects proximity probes to Proximitor modules within the Bently Nevada 3300 XL eddy-current measurement system.\u003c\/p\u003e\n\u003cp\u003eThis 7.5 m armored configuration is used in environments with high mechanical risk, such as heavy industrial skids, offshore platforms, and plant areas with potential cable abrasion or impact exposure. The armored structure increases mechanical protection and improves long-term reliability under vibration and harsh installation conditions.\u003c\/p\u003e\n\u003cp\u003eThe CN approval option supports region-specific compliance requirements while maintaining full compatibility with global 3300 XL monitoring architectures used in power generation and process industries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e075\u003c\/td\u003e\n\u003ctd\u003e7.5 m cable length (24.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eArmored cable construction option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approval configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach segment defines cable length, mechanical protection level, and regulatory compliance classification within the 3300 XL system framework.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-075-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e7.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL armored extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Design\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003ePassive component, no external power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Protection\u003c\/td\u003e\n\u003ctd\u003eArmored cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eUse armored cable in areas with high risk of mechanical impact, abrasion, or cable crushing. Typical applications include compressor skids, turbine enclosures, and offshore installations.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable routing even with armored protection. Armoring does not eliminate EMI sensitivity, so separation from high-voltage lines is still required.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bending at entry and exit points of armored sections. Excess stress can reduce connector alignment stability over time.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Troubleshooting Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main advantage of armored extension cable?\u003c\/strong\u003e\u003cbr\u003eIt provides mechanical protection against impact, abrasion, and crushing in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan armored cable improve signal quality?\u003c\/strong\u003e\u003cbr\u003eNo. It improves mechanical durability only. Signal quality depends on shielding and routing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs CN version different electrically?\u003c\/strong\u003e\u003cbr\u003eNo. CN refers only to compliance approval, not electrical characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes signal instability in armored cable systems?\u003c\/strong\u003e\u003cbr\u003eIncorrect grounding, poor connector engagement, or EMI from nearby power cables.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius even with armored protection to avoid internal conductor stress and shielding degradation.\u003c\/p\u003e\n\u003cp\u003eRoute cable away from VFD output cables and high-current bus systems to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eEnsure proper connector seating during installation. Armored cable rigidity can increase stress at termination points if misaligned.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321399147,"sku":"330130-075-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-075-01-cn-mzzno3tgoem_e92964c4-a83e-42f0-a0d7-27ac6706a298.jpg?v=1765521157"},{"product_id":"bently-nevada-330130-070-00-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-070-00-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eOperational Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-070-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL extension cable used in vibration monitoring systems for turbines, compressors, generators, and other critical rotating equipment. It connects proximity probes to Proximitor modules and ensures stable signal transmission within the eddy-current measurement loop.\u003c\/p\u003e\n\u003cp\u003eThis 7.0 m cable supports medium-range installation layouts in industrial skids and turbine housings. It maintains impedance stability under vibration, thermal cycling, and electrical noise conditions. In condition monitoring systems, this cable plays a direct role in preserving signal accuracy and preventing false vibration alarms that can trigger unnecessary shutdowns.\u003c\/p\u003e\n\u003cp\u003eThe CN configuration provides region-specific compliance support while maintaining full compatibility with standard 3300 XL system architecture used globally in power generation and process industries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCable Structure Interpretation\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e070\u003c\/td\u003e\n\u003ctd\u003e7.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eRegional compliance approval option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe structure defines physical length, construction type, and regulatory classification within the Bently Nevada 3300 XL monitoring ecosystem.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eElectrical \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-070-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e7.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL standard extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Design\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eProcurement Guide (Buying Strategy Notes)\u003c\/h3\u003e\n\u003cp\u003eExtension cables in Bently Nevada systems are not interchangeable without system consideration. Buyers must confirm three key parameters before purchase:\u003c\/p\u003e\n\u003cp\u003eFirst, verify total loop length including probe, extension cable, and Proximitor input requirements. Incorrect length selection affects gap voltage scaling and vibration accuracy.\u003c\/p\u003e\n\u003cp\u003eSecond, confirm connector type compatibility. 3300 XL systems require matched coaxial connector standards to ensure stable signal integrity under vibration conditions.\u003c\/p\u003e\n\u003cp\u003eThird, evaluate environmental exposure. In turbine and compressor installations, cable routing must account for heat, oil mist, and continuous vibration stress.\u003c\/p\u003e\n\u003cp\u003eFor long-term procurement planning, engineers typically standardize cable lengths across multiple machines to simplify spare parts inventory and reduce maintenance complexity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePurchase Notes (Compliance \u0026amp; Risk Control)\u003c\/h3\u003e\n\u003cp\u003eThis product is designed for industrial monitoring systems only and must be installed by qualified instrumentation personnel.\u003c\/p\u003e\n\u003cp\u003eIncorrect installation or mismatch with non-3300 XL components may result in signal distortion or monitoring failure.\u003c\/p\u003e\n\u003cp\u003eCN approval versions are intended for region-specific regulatory compliance. Buyers should confirm required certification scope before deployment in hazardous areas.\u003c\/p\u003e\n\u003cp\u003eAll cables should be stored in controlled environments before installation to avoid insulation aging or connector contamination.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain physical separation between signal cables and high-voltage power lines to reduce electromagnetic interference in VFD-driven systems.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bends during installation. Excess mechanical stress may degrade shielding performance and long-term impedance stability.\u003c\/p\u003e\n\u003cp\u003eUse single-point grounding at the monitoring system level. Multiple grounding points can introduce loop current and measurement drift.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Troubleshooting Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes unstable vibration readings in extension cable systems?\u003c\/strong\u003e\u003cbr\u003eImproper routing, damaged shielding, or loose connector engagement are the most common causes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan incorrect cable length affect system calibration?\u003c\/strong\u003e\u003cbr\u003eYes. Total loop length must match system design to ensure correct gap voltage output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs CN version different in electrical performance?\u003c\/strong\u003e\u003cbr\u003eNo. CN only defines compliance approval, not electrical characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the most common installation error?\u003c\/strong\u003e\u003cbr\u003eIncorrect cable routing near power conductors and improper connector locking.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure controlled routing from probe to Proximitor to avoid EMI coupling in turbine and compressor environments.\u003c\/p\u003e\n\u003cp\u003eVerify ClickLoc connector engagement during installation. Partial locking may cause intermittent signal loss under vibration.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius throughout cable path to preserve shielding integrity and impedance stability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321464683,"sku":"330130-070-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-070-00-cn-standard-extension-cable-on0jgnrrs1t_360967c8-6bde-432f-8b76-06a29971e9d1.jpg?v=1765448949"},{"product_id":"330190-080-00-00-bently-nevada-3300-xl-extended-temperature-range-etr-extension-cable","title":"330190-080-00-00 | Bently Nevada | 3300 XL Extended Temperature Range (ETR) Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330190-080-00-00\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a Bently Nevada 3300 XL Extended Temperature Range (ETR) extension cable engineered for vibration monitoring systems in turbines, compressors, and critical rotating machinery. It supports stable signal transmission between proximity probes and Proximitor sensors in high-temperature industrial environments such as power plants, oil refineries, and mining operations.\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL ETR cable maintains measurement integrity under thermal stress and continuous vibration exposure. It uses a 75 ohm triaxial structure with FEP insulation to improve dielectric stability and chemical resistance. This design reduces signal drift and helps condition monitoring systems maintain accurate shaft displacement and vibration data.\u003c\/p\u003e\n\u003cp\u003eOperators use this cable in environments where standard extension cables fail due to elevated temperature or chemical exposure. It directly supports machine protection strategies by reducing false alarms and preventing unnecessary shutdown events in critical production assets.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration Logic\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330190\u003c\/td\u003e\n\u003ctd\u003e3300 XL Extended Temperature Range extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 m cable length (26.2 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe ETR design focuses on thermal resilience rather than certification variants. The structure uses triaxial geometry with FEP insulation to maintain electrical stability in elevated temperature zones.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-080-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.289 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, FEP insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard coiled industrial cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component, no power required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe extension in rotating machinery systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL ETR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Impedance\u003c\/td\u003e\n\u003ctd\u003e75 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs 330190-080-00-00 compatible with standard 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes. It works with Bently Nevada 3300 XL proximity transducer systems when used with compatible probes and Proximitor sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main advantage of ETR cable over standard extension cable?\u003c\/strong\u003e\u003cbr\u003eETR cable provides higher temperature tolerance and improved insulation stability in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable operate in turbine casing environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly installed in turbine housings where heat and vibration exceed standard cable limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect calibration?\u003c\/strong\u003e\u003cbr\u003eYes. System loop calibration must match total probe, extension, and Proximitor configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain proper separation between signal cables and power wiring to reduce electromagnetic interference in high-noise environments such as VFD-driven compressor systems.\u003c\/p\u003e\n\u003cp\u003eDo not exceed minimum bend radius during installation. Mechanical stress on triaxial shielding can degrade signal stability over time.\u003c\/p\u003e\n\u003cp\u003eIn high-temperature zones, route cables away from direct radiant heat sources. Use approved clamps to prevent vibration fatigue at connector points.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321562987,"sku":"330190-080-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330190-080-00-00-t5xmwdt0s2f_f4696e94-58d3-48ed-8cbe-71176a8767dd.jpg?v=1765521163"},{"product_id":"bently-nevada-330130-075-10-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-10-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-075-10-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL standard extension cable designed for high-reliability vibration monitoring systems in refineries, gas turbines, steam turbines, compressors, and power generation assets. This extension cable connects 3300 XL proximity probes to Proximitor sensors and maintains signal integrity in continuous condition monitoring applications.\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL series supports critical rotating equipment protection where stable vibration data directly reduces unplanned shutdown risk. Bently Nevada uses high-performance coaxial construction and industrial-grade shielding to improve resistance against electrical noise, oil contamination, and mechanical stress.\u003c\/p\u003e\n\u003cp\u003eThe 7.5 m cable configuration fits medium-distance field installations inside turbine enclosures, compressor skids, and hazardous process environments. The FluidLoc cable option improves sealing performance in oil-exposed applications and helps prevent fluid migration through the cable assembly. The -CN suffix identifies the China hazardous area approval package, including applicable NEPSI and related regional certifications for explosive gas environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e075\u003c\/td\u003e\n\u003ctd\u003e7.5 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eFluidLoc cable option with enhanced fluid resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eChina hazardous area approval package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-075-10-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e7.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFluidLoc coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eStandard Bently Nevada compatible connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive device, no external power required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade shielded coaxial construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe extension connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Approval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area approval package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL proximity transducer systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Details\u003c\/h3\u003e\n\u003cp\u003eThe 330130 extension cable operates within Bently Nevada proximity transducer systems used for shaft vibration and position monitoring. Engineers commonly install this cable in centrifugal compressors, steam turbines, hydro turbines, and critical motor systems.\u003c\/p\u003e\n\u003cp\u003eFluidLoc technology improves reliability in oil-rich turbine compartments and lubrication-intensive machinery areas. The cable construction minimizes moisture ingress and maintains stable signal transmission during long-term operation under vibration and thermal cycling conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 330130-075-10-CN compatible with all 3300 XL probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable supports standard Bently Nevada 3300 XL 8 mm proximity transducer systems with compatible probe and Proximitor configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the FluidLoc option provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc cable structure reduces fluid migration through the cable jacket. This feature improves reliability in turbine oil and compressor lubrication environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable operate in hazardous areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The -CN suffix includes China hazardous area approvals for applicable explosive gas installations when used within approved system configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this extension cable require calibration after replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEngineers should verify the complete transducer system length and perform gap voltage validation after installation. System calibration depends on the total matched probe system configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eUse dedicated cable routing away from high-voltage motor cables and VFD output wiring. Proper separation reduces electromagnetic interference during vibration signal transmission.\u003c\/p\u003e\n\u003cp\u003eDo not exceed the specified bending radius during installation. Excessive cable stress may affect shielding performance and long-term signal stability.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing surfaces before installation in oil-contaminated environments. Clean mating surfaces improve environmental protection and connector reliability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321595755,"sku":"330130-075-10-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-075-10-cn-x4tc333h1cw_af9c6aa5-972e-4176-816c-11238e244953.jpg?v=1765521164"},{"product_id":"bently-nevada-16925-80-interconnect-cable-without-armor","title":"Bently Nevada 16925-80 Interconnect Cable Without Armor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16925-80\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada interconnect cable designed for signal transmission within industrial vibration monitoring systems where flexible routing is required. It connects system modules, proximity measurement chains, and monitoring interfaces in Bently Nevada architectures used for rotating machinery protection. The cable maintains stable electrical performance in environments with continuous vibration and electrical noise.\u003c\/p\u003e\n\u003cp\u003eThis model is commonly deployed in power plants, oil refineries, compressor stations, and heavy industrial facilities. It supports reliable communication between monitoring components while reducing installation complexity in non-armored routing applications. The absence of armor improves flexibility for cabinet and rack wiring layouts where mechanical protection is already provided by conduit or controlled installation paths.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16925 = Interconnect cable base model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e80 = 80 ft fixed cable length option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWithout armor = flexible standard cable construction without mechanical steel protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable is designed for internal system interconnection where routing flexibility is prioritized over mechanical reinforcement. It maintains stable impedance characteristics suitable for vibration signal transmission in Bently Nevada monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16925-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable Without Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e80 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eNon-armored flexible industrial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring system interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade shielded cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eCabinet and rack wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.131 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the 16925-80 cable typically installed?\u003c\/strong\u003e\u003cbr\u003eIt is used inside control cabinets, racks, and protected industrial wiring paths for monitoring system interconnection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable provide mechanical protection against crushing?\u003c\/strong\u003e\u003cbr\u003eNo. It is non-armored and relies on installation routing or conduit for mechanical protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high vibration environments?\u003c\/strong\u003e\u003cbr\u003eYes, but it must be installed in protected routing paths to avoid mechanical damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with all Bently Nevada systems?\u003c\/strong\u003e\u003cbr\u003eIt is compatible only when system interconnection specifications match the required length and connector configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the cable inside protected conduits or cable trays when used in high vibration industrial environments. Avoid direct exposure to moving machinery or sharp edges.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high voltage power cables and VFD output lines to reduce electromagnetic interference and signal distortion.\u003c\/p\u003e\n\u003cp\u003eUse proper grounding for cable shielding at a single reference point to prevent ground loop noise in vibration monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321825131,"sku":"16925-80","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16925-80-a351m02eaoc_7af58e61-be66-4f3a-bb94-2662eec300f9.jpg?v=1765521172"},{"product_id":"16925-23-bently-nevada-interconnect-cable","title":"16925-23| Bently Nevada | Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16925-23\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada interconnect cable designed for reliable signal transmission between vibration monitoring components in industrial protection systems. It forms part of the signal path used in proximity, velocity, and condition monitoring architectures where stable electrical continuity directly affects measurement accuracy and machine protection response time.\u003c\/p\u003e\n\u003cp\u003eThis cable is widely used in turbine systems, compressors, pumps, and rotating machinery installations across power generation, oil and gas, and heavy industrial plants. It ensures consistent signal integrity between field sensors and monitoring modules, reducing the risk of data loss caused by electromagnetic interference or mechanical stress in harsh environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16925 = Interconnect cable base model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e23 = 23 ft cable length configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable is designed for direct interconnection within Bently Nevada monitoring systems. It maintains controlled electrical characteristics suitable for vibration signal transmission and supports stable operation under continuous industrial vibration and electrical noise conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16925-23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e23 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Function\u003c\/td\u003e\n\u003ctd\u003eSignal interconnection for monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring system wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada condition monitoring platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade shielded construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eIndustrial machinery and control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the 16925-23 cable used in a monitoring system?\u003c\/strong\u003e\u003cbr\u003eIt is used as an interconnect link between vibration monitoring modules and system components in Bently Nevada architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high noise environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed with shielding suitable for industrial electromagnetic interference environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable length fixed at 23 ft?\u003c\/strong\u003e\u003cbr\u003eYes. The “23” suffix defines a fixed 23 ft factory configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable replace other interconnect models?\u003c\/strong\u003e\u003cbr\u003eReplacement is possible only if electrical and length specifications match system requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the cable away from high voltage power lines and VFD output cables to minimize induced electrical noise. Separation improves signal stability in vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003eAvoid tight bending near connectors and junction points. Excess mechanical stress can degrade shielding performance and reduce long-term reliability.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of cable shielding at a single system reference point to prevent ground loop interference in turbine and compressor monitoring environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321857899,"sku":"16925-23","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/16925-23-104ffwk3jjl_edf3297d-cdab-4cf7-9cbf-0d5dff551175.jpg?v=1765521173"},{"product_id":"bently-nevada-330130-180-00-cn-3300-xl-extension-cable-assembly","title":"Bently Nevada 330130-180-00-CN 3300 XL Extension Cable Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-180-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL extension cable designed for reliable signal transmission in proximity probe vibration monitoring systems. This cable is part of the 3300 XL transducer chain used in turbines, compressors, pumps, and critical rotating machinery where uninterrupted vibration data ensures safe plant operation. It supports stable electrical continuity between probe and proximitor module in high-noise industrial environments.\u003c\/p\u003e\n\u003cp\u003eThis model has been replaced by 330130-080-00-CN in updated configurations, but it remains widely used in installed base systems across oil refineries, power generation plants, and offshore platforms. The CN suffix indicates China-specific hazardous area approval coverage, including NEPSI-related compliance for explosive environments. Its robust construction ensures consistent impedance behavior and minimizes signal degradation over extended routing distances.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330130 = 3300 XL extension cable platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e180 = cable length option (system-specific legacy configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00 = standard cable with no additional connector protection features\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN = China country-specific hazardous area approvals (NEPSI compliance support)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable is engineered with controlled impedance design to maintain accurate proximity probe signal transmission. It integrates directly into Bently Nevada 3300 XL systems without additional signal conditioning requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-180-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Option\u003c\/td\u003e\n\u003ctd\u003e180 (legacy system configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Protection\u003c\/td\u003e\n\u003ctd\u003eStandard (00 option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Weight\u003c\/td\u003e\n\u003ctd\u003e0.034 kg\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Shipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Function\u003c\/td\u003e\n\u003ctd\u003eSignal transmission for proximity system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL probe and proximitor systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade shielded construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs 330130-180-00-CN still supported in modern systems?\u003c\/strong\u003e\u003cbr\u003eIt is supported in installed base systems but replaced by 330130-080-00-CN in updated configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be mixed with other 3300 XL cable lengths?\u003c\/strong\u003e\u003cbr\u003eYes, but total system calibration must remain within Bently Nevada recommended limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does CN approval indicate for this cable?\u003c\/strong\u003e\u003cbr\u003eCN indicates China-specific hazardous area certification compliance including NEPSI-related approvals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes signal noise in extension cable systems?\u003c\/strong\u003e\u003cbr\u003eImproper grounding, cable routing near VFDs, or damaged shielding typically introduces signal noise.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eMaintain continuous shielding integrity across the full cable run to avoid electromagnetic interference. Broken shielding increases vibration signal distortion.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bending radius during installation. Excess mechanical stress can alter impedance characteristics and degrade measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eRoute extension cables separately from power cables and variable frequency drive lines. Proper separation improves long-term signal stability in industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321956203,"sku":"330130-180-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-180-00-cn-xobbvbfka1q_27b330d4-a1d9-4704-b95a-11f8b24b3c74.jpg?v=1765521178"},{"product_id":"bently-nevada-330930-065-04-cn-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-04-CN 3300 NSv Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-065-04-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 NSv extension cable designed for signal transmission within compact proximity transducer systems used in turbines, compressors, pumps, and other rotating machinery. This extension cable supports industrial applications in refineries, power plants, and petrochemical facilities where reliable vibration and shaft position monitoring is essential. The stainless steel armored construction with FEP jacket improves resistance against abrasion, oil exposure, moisture, and chemical contamination. Connector protectors enhance long term connection stability under vibration conditions. Engineers use this cable to maintain signal integrity between NSv probes and proximitor sensors, reducing measurement errors and preventing unexpected machinery downtime in hazardous operating environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code defines cable configuration and hazardous area compliance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e065\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Cable length 6.5 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Stainless steel armored cable with FEP jacket and connector protectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= China-specific hazardous area approvals including NEPSI, CCC, and ATEX IECEx compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration ensures compatibility with harsh industrial installations and hazardous area requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330930-065-04-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.5 metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStainless steel armored FEP cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated connector protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity transducer systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary application of this extension cable?\u003c\/strong\u003e\u003cbr\u003eIt connects 3300 NSv probes and proximitor sensors in machinery monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does this model use an FEP jacket?\u003c\/strong\u003e\u003cbr\u003eThe FEP jacket provides enhanced resistance to chemicals, oil, and high temperature environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the CN suffix indicate?\u003c\/strong\u003e\u003cbr\u003eIt confirms compliance with China-specific hazardous area certifications including NEPSI and CCC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable operate in high vibration environments?\u003c\/strong\u003e\u003cbr\u003eYes. The stainless steel armor improves mechanical protection and vibration resistance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from motor power wiring to minimize electromagnetic interference.\u003cbr\u003eInspect connector protectors regularly to prevent contamination or moisture ingress.\u003cbr\u003eUse secure mounting supports to reduce cable movement and prevent armor fatigue in vibrating installations.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322087275,"sku":"330930-065-04-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-065-04-cn-jguk1yd4xlq_b81f867b-ecb4-4b73-9360-4f8aa648ca8e.jpg?v=1765521186"},{"product_id":"bently-nevada-330130-075-12-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-12-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-075-12-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL standard extension cable designed for use within 3300 XL 8 mm proximity transducer systems. This cable provides stable signal transmission between proximity probes and proximitor sensors in rotating machinery monitoring applications. Industries such as oil refining, gas compression, and power generation rely on this extension cable for continuous vibration and shaft position monitoring. The FluidLoc cable construction improves resistance to oil ingress and harsh environmental exposure, while the connector protector enhances long term connector reliability. Its CN hazardous area approval supports safe deployment in explosive gas and dust environments, helping operators maintain reliable machine protection and reduce unplanned outages.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model structure defines cable length, mechanical protection, and certification:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e075\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Cable length 7.5 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= FluidLoc cable with connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= ATEX IECEx and Chinese NEPSI hazardous area approval marking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration ensures compatibility with hazardous area installations and demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-075-12-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e34 g per metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.5 metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFluidLoc industrial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eATEX IECEx and NEPSI certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the FluidLoc cable design?\u003c\/strong\u003e\u003cbr\u003eFluidLoc construction helps prevent oil migration and improves long term cable durability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with 3300 XL proximity systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is specifically designed for Bently Nevada 3300 XL transducer systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the CN approval indicate?\u003c\/strong\u003e\u003cbr\u003eIt confirms compliance with Chinese NEPSI and international ATEX IECEx hazardous area standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable operate in high vibration environments?\u003c\/strong\u003e\u003cbr\u003eYes. The reinforced industrial design supports reliable operation under continuous vibration exposure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the extension cable separately from high voltage conductors to reduce electromagnetic interference.\u003cbr\u003eInspect connector protectors during maintenance intervals to prevent moisture or contamination ingress.\u003cbr\u003eUse secure mounting clamps to minimize cable movement and mechanical fatigue in vibrating equipment areas.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322185579,"sku":"330130-075-12-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-075-12-cn-zervmrm23oa_e970c39d-6b24-4dd4-b7dd-1976f9734346.jpg?v=1765521189"},{"product_id":"bently-nevada-330130-075-12-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-12-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-075-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL standard extension cable from Bently Nevada is designed for reliable signal transmission in proximity probe monitoring systems used in turbines, compressors, pumps, and other critical rotating machinery. It is widely applied in power generation, oil and gas processing, petrochemical plants, and heavy industrial facilities where stable vibration monitoring is essential for preventing equipment failure and unplanned downtime.\u003c\/p\u003e\n\u003cp\u003eThis extension cable is part of the 3300 XL transducer system and ensures accurate signal integrity between proximity probes and monitoring modules. The 7.5 meter cable length provides flexible installation routing in large machinery systems and industrial enclosures. The FluidLoc design with connector protector improves resistance against moisture ingress and contamination in harsh environments. The CSA, ATEX, and IECEx approval package supports hazardous area installations requiring international compliance standards. The cable maintains consistent electrical performance under continuous industrial vibration and thermal variation conditions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e075\u003c\/td\u003e\n\u003ctd\u003eCable length: 7.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eFluidLoc cable with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-075-12-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e7.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Rating\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e34 g\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL proximity monitoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade triaxial shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the FluidLoc design?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc design helps prevent moisture ingress and contamination at connector points in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with all 3300 XL probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is designed for use within the Bently Nevada 3300 XL proximity measurement system when properly matched with probes and Proximitor sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in hazardous areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports CSA, ATEX, and IECEx approvals for use in explosive gas and dust environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect system performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Proper system matching is required to maintain signal accuracy and calibration consistency in vibration monitoring systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute extension cables separately from power cables and VFD outputs to reduce electromagnetic interference in monitoring systems.\u003c\/p\u003e\n\u003cp\u003eEnsure connector protector is properly engaged to maintain sealing integrity in high humidity or contaminated environments.\u003c\/p\u003e\n\u003cp\u003eUse proper cable support along trays to prevent mechanical stress and vibration fatigue at connector interfaces.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322480491,"sku":"330130-075-12-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-075-12-05-fxkf3o2r1nz_d311a868-deca-49a3-93aa-9d9d1b0d655d.jpg?v=1765521199"},{"product_id":"bently-nevada-18622-015-01-interconnect-cable-assembly","title":"Bently Nevada 18622-015-01 Interconnect Cable Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e18622-015-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterconnect cable from Bently Nevada provides reliable signal transmission between vibration monitoring system components in industrial machinery protection applications. It is widely used in power generation plants, oil refineries, petrochemical facilities, and heavy industrial equipment where stable communication between proximity probes, extension systems, and monitoring modules is required for continuous machine condition monitoring.\u003c\/p\u003e\n\u003cp\u003eThis interconnect cable is designed for integration within Bently Nevada monitoring architectures and supports stable electrical signal transfer under high vibration and harsh environmental conditions. The 15 ft (4.572 m) cable length provides flexible installation routing between enclosure systems and field-mounted instrumentation. The armored Teflon cable construction improves resistance to abrasion, chemical exposure, and mechanical stress, making it suitable for demanding industrial environments. The compact design supports clean cable management inside control cabinets and machinery protection systems, helping maintain signal integrity and reducing the risk of unplanned shutdown events caused by wiring degradation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e18622\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable series identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e015\u003c\/td\u003e\n\u003ctd\u003eCable length: 15 ft (4.572 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eArmored Teflon cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e18622-015-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e15 ft (4.572 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored, Teflon insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade signal shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main function of this interconnect cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides stable signal transmission between vibration monitoring components in Bently Nevada machinery protection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is Teflon insulation used in this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTeflon improves resistance to high temperature, chemical exposure, and industrial environmental stress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high vibration environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The armored construction is designed for industrial vibration and mechanical stress conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with all Bently Nevada systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is designed for use within compatible Bently Nevada monitoring and proximity measurement architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from high power conductors and VFD output lines to minimize electromagnetic interference in monitoring signals.\u003c\/p\u003e\n\u003cp\u003eEnsure proper mechanical fixation along cable trays to prevent vibration-induced fatigue at connector points in rotating machinery environments.\u003c\/p\u003e\n\u003cp\u003eAvoid tight bending near termination points to maintain long-term shielding integrity and stable signal performance in industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322644331,"sku":"18622-015-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/18622-015-01-vtm1cdyn4v0_d9fb4d7d-b80f-478a-a0ad-8e330fa758a2.jpg?v=1765521204"},{"product_id":"bently-nevada-330130-085-01-05-3300-xl-extension-cable","title":"Bently Nevada 330130-085-01-05 3300 XL Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-085-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL extension cable from Bently Nevada supports high-accuracy vibration and proximity monitoring systems used in turbines, compressors, pumps, and critical rotating machinery. This armored extension cable operates as part of the 3300 XL transducer system and provides stable signal transmission between the proximity probe and Proximitor sensor. Power generation plants, refinery facilities, LNG terminals, and petrochemical sites commonly install this cable in high-vibration industrial environments where signal integrity directly affects machine protection reliability.\u003c\/p\u003e\n\u003cp\u003eThe armored construction improves resistance against mechanical damage, oil exposure, and cable tray abrasion. The multiple approval configuration supports installation in hazardous industrial areas that require international certification compliance. The 8.5 m cable length allows flexible routing inside turbine enclosures, compressor skids, and machinery cabinets while maintaining proper electrical characteristics for the 3300 XL monitoring system.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL Extension Cable Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e085\u003c\/td\u003e\n\u003ctd\u003e8.5 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eArmored cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-085-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eArmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e34 g\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eClickLoc coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003eFluoroethylene propylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eFactory shielded coaxial construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this extension cable operate with older 3300 monitoring systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable supports 3300 XL proximity systems directly. Compatibility with legacy 3300 systems depends on probe and Proximitor configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the armored version improve reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe armored structure protects the cable from crushing, abrasion, vibration stress, and accidental mechanical impact in industrial installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the cable length affect proximity probe calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Bently Nevada proximity systems require matched electrical lengths between the probe, extension cable, and Proximitor sensor for accurate measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 05 approval option suitable for hazardous locations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The multiple approval option supports installations requiring international hazardous area certifications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the extension cable separately from high-voltage motor cables to reduce electromagnetic interference. Maintain proper grounding practices at the monitoring cabinet to improve signal stability.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive bending near connector assemblies during installation. Tight bend radius conditions may affect long-term shielding integrity and connector performance.\u003c\/p\u003e\n\u003cp\u003eUse proper cable clamps inside turbine and compressor skids to minimize vibration transfer into the connector interface. High-vibration environments require stable mechanical support for reliable monitoring operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322840939,"sku":"330130-085-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-085-01-05-3300-xl-standard-extension-cable-gd44ssimpmp_c73fb525-5a79-4902-b8ed-5e98f0f9286c.jpg?v=1765446982"},{"product_id":"bently-nevada-16710-65-interconnect-cable-1","title":"Bently Nevada 16710-65 Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65 \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty, 3-conductor shielded interconnect cable designed to maintain signal integrity between proximity transducers and monitoring systems. Engineered for the Bently Nevada 3300 and 3500 Machinery Protection Systems, this cable is essential for transmitting critical vibration, position, and speed data in high-interference industrial environments. Its armored construction provides superior mechanical protection against physical abrasion and crushing forces commonly found in oil refineries, power plants, and heavy manufacturing facilities. By utilizing high-grade 22 AWG wiring and robust shielding, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeffectively eliminates electromagnetic interference (EMI) that can cause false alarms or signal drift. Implementing genuine Bently Nevada cabling is a vital strategy for ensuring the reliability of Turbomachinery Instrumentation (TSI), directly reducing unplanned downtime through stable, high-fidelity data transmission.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a specific Bently Nevada configuration logic for length and termination:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16710:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the base cable assembly type. This includes a 3-conductor, 22 AWG (0.5 mm2) shielded wire housed within flexible stainless steel armor. The assembly features a pre-installed 3-socket plug at the sensor end and terminal lugs at the monitor end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-65:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates the total cable length. In this configuration, the cable is precisely manufactured to a length of 65 feet (approximately 20 meters), allowing for significant distance between the field-mounted junction box and the centralized control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16710-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Conductor Shielded Armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 feet (20 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Socket Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the armored jacket provide environmental sealing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stainless steel armor provides exceptional mechanical protection against impact and abrasion; however, it is not a liquid-tight seal. For applications involving constant immersion or heavy chemical spray, the cable should be routed through additional liquid-tight conduit or housed in sealed trays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be shortened in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the terminal lug end can technically be trimmed, it is not recommended as it destroys the factory-certified termination. Field modifications can introduce impedance mismatches or shielding gaps. It is best practice to order the specific length required for the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the shield connected to the socket plug?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shield is typically isolated at the sensor end plug to prevent ground loops. In a standard Bently Nevada installation, the shield should be grounded only at the monitor rack or the common point in the signal conditioning housing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProper grounding is the most critical factor when installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-65\u003c\/strong\u003e. The cable shield must be terminated at the instrument ground in the 3500 rack or the Proximitor housing. Ensure the shield is not inadvertently grounded at the sensor end or at any intermediate junction boxes. \"Floating\" the shield at the sensor end prevents circulating ground currents that can corrupt low-voltage vibration signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius and Mechanical Stress\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDespite the flexible armor, the cable has a minimum bend radius that must be respected to prevent internal conductor fatigue. Avoid sharp 90-degree bends. When securing the cable to machine supports or tray systems, use stainless steel ties or clamps that do not compress the armor, as internal insulation damage can lead to intermittent short circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn Class 1 Div 1 or Zone 0\/1 environments, ensure the armored cable is installed in accordance with local explosion-proof or intrinsically safe wiring standards. The armor provides mechanical protection but does not replace the need for certified cable glands or seals where the cable enters a pressurized or flameproof enclosure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322906475,"sku":"16710-65","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-65-interconnect-cable-y3wsgre5hbc_116b3aaa-6d35-48c4-a8bf-f4c822366c20.jpg?v=1765447167"},{"product_id":"106765-25-bently-nevada-interconnect-cable","title":"106765-25 | Bently Nevada | Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a specialized, ruggedized interconnect cable assembly designed specifically for the Bently Nevada 330525 Velomitor XA (eXtended Application) Piezo-Velocity Sensor series. In critical industrial sectors such as power generation, wastewater treatment, and offshore oil platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the vital link for transmitting high-fidelity vibration data in high-moisture and corrosive environments. By utilizing a unique weatherproof connector system, this cable allows for the direct mounting of sensors without the need for additional protective housings. This streamlined architecture significantly reduces installation complexity while ensuring maximum uptime for rotating assets by maintaining IP-65 and NEMA 4X sealing integrity under the most grueling field conditions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown: 106765-AA\u003c\/h3\u003e\n\u003cp\u003eThe 106765 series uses a modular suffix system to ensure the precise cable reach required for specific machine train geometries:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e106765 Base Model:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDenotes the high-performance interconnect cable assembly designed for Velomitor XA sensors, featuring 316L stainless steel hardware compatibility and weatherproof sealing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAA Option (Length):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDefines the total cable length in meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-25 Suffix:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRepresents a fixed length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25 meters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(approximately 82 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Bently Nevada practice dictates that these specialized cables are typically engineered and ordered in 3-meter increments to maintain electrical impedance consistency across the monitoring loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e106765-25\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Sensors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330525 Velomitor XA Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 meters (82 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP-65 and NEMA 4X (When properly mated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-55 to +121 deg C (-67 to +250 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWeatherproof high-grade synthetic \/ Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Insights \u0026amp; FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 106765-25 compatible with the standard 330500 Velomitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the internal wiring may be similar, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for the \"XA\" (Extended Application) version. The XA series features a unique connector intended for use without a separate housing. Using this cable on a standard 330500 may compromise the environmental seal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the cable handle exposure to chemicals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable jacket and connector materials are selected for high resistance to moisture and industrial contaminants. When coupled with the 316L stainless steel case of the 330525 sensor, the assembly provides superior protection against the corrosive atmospheres common in mining and chemical processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 25-meter length affect signal accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Bently Nevada piezo-velocity systems are designed to drive signals over significant distances. A 25-meter run is well within the operational parameters, provided the cable is routed away from high-voltage interference sources.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing and Moisture Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo achieve the full NEMA 4X and IP-65 rating, the connector must be properly seated and tightened. In outdoor or wash-down areas, engineers should apply a light coating of silicone lubricant to the connector threads (avoiding the pins) to ensure a gas-tight seal and prevent thread galling over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRouting and Mechanical Stress Relief\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGiven the 25-meter span, the cable must be supported in cable trays or conduits. Avoid tight bends that exceed the minimum bend radius (typically 10 times the cable diameter). At the sensor end, provide a small \"drip loop\" to prevent condensed moisture from traveling down the cable and pooling at the connector interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectromagnetic Interference (EMI) Mitigation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEven with ruggedized shielding, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshould be kept at least 0.3 meters (1 foot) away from high-power AC lines and Variable Frequency Drives (VFDs). If the cable must cross a power line, it should do so at a 90-degree angle to minimize the risk of signal noise.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323332459,"sku":"106765-25","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/106765-25-ecuptpeq1ej_127c5dd4-5d11-493b-9515-aa205caa414c.jpg?v=1765521227"},{"product_id":"bently-nevada-84510-50-standard-or-armored-22-awg-extension-cable","title":"Bently Nevada 84510-50 Standard or Armored 22 AWG Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e84510-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada standard or armored 22 AWG extension cable designed for reliable signal transmission in vibration monitoring and proximity measurement systems. It is widely used in power plants, petrochemical facilities, and heavy rotating machinery installations where stable electrical connectivity is required. This cable supports 3 conductor 0.5 mm2 wiring with a 3 socket plug on one end and terminal ring lugs on the other. Engineers use it to maintain signal integrity between probes and monitoring systems under harsh industrial conditions. Its armored construction option improves resistance to mechanical stress, vibration, and environmental contamination, ensuring consistent performance and reduced system downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis model follows a standardized industrial cable architecture:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e3 conductor 22 AWG (0.5 mm2) shielded cable design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne end equipped with 3 socket plug for direct system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpposite end terminated with ring lugs for secure panel or terminal connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailable in standard or armored construction depending on installation environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for compatibility with Bently Nevada proximity and vibration monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration ensures stable signal transmission and flexible installation across industrial monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e84510-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCable assembly, configurable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive signal cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3 conductor 22 AWG shielded or armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e3 socket plug and ring lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and proximity monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with all Bently Nevada proximity systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for use with standard Bently Nevada proximity and vibration monitoring configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between standard and armored versions?\u003c\/strong\u003e\u003cbr\u003eArmored versions provide additional mechanical protection against vibration, abrasion, and industrial damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used in high temperature environments?\u003c\/strong\u003e\u003cbr\u003eYes. It supports operation up to 121 deg C depending on installation conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes signal degradation in extension cables?\u003c\/strong\u003e\u003cbr\u003ePoor grounding, improper shielding termination, or cable damage can reduce signal quality.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eEnsure proper grounding of the cable shield at one end only to avoid ground loop interference.\u003cbr\u003eRoute cables away from high voltage power lines to maintain signal stability and reduce noise.\u003cbr\u003eUse secure cable clamps to prevent mechanical fatigue in high vibration environments.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323365227,"sku":"84510-50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/84510-50-pg3secpfjvo_44fe890c-dfc1-404b-b7e8-ca1ed5c4e6e8.jpg?v=1765521228"},{"product_id":"bently-nevada-330130-080-03-cn-3300-xl-standard-extension-cable-1","title":"Bently Nevada 330130-080-03-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-080-03-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL standard extension cable designed for reliable signal transmission between proximity probes and proximitor sensors in rotating equipment monitoring systems. This cable operates in demanding industries such as oil and gas, power generation, and petrochemical processing. It ensures consistent signal integrity over extended distances, which is critical for accurate vibration and displacement measurement. The armored construction with connector protectors enhances durability against mechanical stress, moisture, and industrial contaminants. Engineers use this cable to maintain stable system performance and reduce diagnostic errors. The CN approval ensures compliance with China hazardous area standards, supporting safe operation in explosive gas and dust environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model configuration defines cable structure and compliance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e080\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Cable length 8.0 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= Armored cable with connector protectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e= China-specific hazardous area approvals including NEPSI, CCC, and ATEX IECEx\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis coding structure ensures correct installation length and suitability for hazardous environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-080-03-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.0 metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eArmored industrial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eStandard 3300 XL connectors with protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with 3300 XL proximity systems?\u003c\/strong\u003e\u003cbr\u003eYes. It supports full compatibility with 3300 XL probes and proximitor sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between option 03 and other cable types?\u003c\/strong\u003e\u003cbr\u003eOption 03 provides armored protection with connector protectors for enhanced mechanical durability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the CN suffix indicate?\u003c\/strong\u003e\u003cbr\u003eIt confirms compliance with China-specific hazardous area certification standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable handle harsh industrial environments?\u003c\/strong\u003e\u003cbr\u003eYes. The armored design resists vibration, oil exposure, and mechanical damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eRoute the cable separately from high voltage cables to minimize electromagnetic interference.\u003cbr\u003eUse proper cable clamps to prevent movement and reduce fatigue under vibration.\u003cbr\u003eCheck connector sealing during installation to maintain protection against moisture ingress.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323496299,"sku":"330130-080-03-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-080-03-cn-3300-xl-standard-extension-cable-2uhlynzxar5_26521c9d-5472-41b4-90f9-20cdc6ddbdaa.jpg?v=1765444111"},{"product_id":"330130-080-13-cn-bently-nevada-3300-xl-standard-extension-cable","title":"330130-080-13-CN | Bently Nevada | 3300 XL Standard Extension Cable","description":"\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-080-13-CN \u003c\/strong\u003estandard extension cable is a high-integrity signal transmission link engineered for the 3300 XL 8 mm proximity transducer system. Deployed extensively in high-vibration, chemically aggressive environments like steam turbine generator sets, large-scale refining compressors, and heavy mining excavators, this armored cable preserves the precise RF signal between the sensor probe and the Proximitor. Featuring integrated fluid-blocking technology, it prevents process liquids and high-pressure steam from leaking through the cable core into delicate junction boxes. Integrating this heavy-duty, armored extension line ensures steady, noise-free machine diagnostics, shielding your critical turbomachinery loops against false trips and minimizing unplanned downtime.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configurations\u003c\/h3\u003e\n\u003cp\u003eThe precise engineering suffix structure of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-080-13-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eextension cable designates its length, mechanical armor, and global regulatory compliance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330130\u003c\/strong\u003e: Base model designator for the high-performance 3300 XL Standard Extension Cable series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e080\u003c\/strong\u003e: Cable Length Option specifying exactly 8.0 metres (26.2 feet) of calibrated electrical length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e13\u003c\/strong\u003e: Connector Protector and Cable Option equipping a ruggedized stainless steel outer armor, FluidLoc gas\/liquid-tight internal sealing, and a pre-installed protective sleeve for the coaxial junction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: China-specific hazardous area approvals, covering NEPSI and CCC requirements alongside ATEX\/IECEx certifications for intrinsically safe or flameproof operations in volatile gas and dust environments. This globally procured version ensures compliance for equipment intended for, or compatible with, Chinese industrial markets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Field\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Parameter Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-080-13-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm coaxial transmission path\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOuter Construction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless steel flexible protective armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Sealing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc moisture-proof and gas-tight core barrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJunction Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMolded ClickLoc connector protector sleeve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to 177 deg C (-60 deg F to 351 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Cable Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGross Shipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg (including protective industrial packing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Field FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the exact 8.0 metres length of this cable critical for system calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Eddy current proximity sensors rely on a tuned resonant circuit calibrated to a specific total electrical length (typically 9.0 metres). Pairing an 8.0 metres extension cable with a 1.0 metre probe matches this exact calibration profile. Mismatching these lengths will cause severe linearity errors in your gap and vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary purpose of the FluidLoc seal in the \"13\" option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The FluidLoc feature is an internal barrier inside the coaxial cable that blocks oil, water, or process gases from flowing inside the cable jacket. This is vital when the probe is mounted inside a pressurized oil-mist environment, preventing process fluids from migrating into the external field wiring cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this armored extension cable be installed in cable trays without conduit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The flexible stainless steel armor provides robust mechanical protection against crushing, abrasive wear, and cutting. It allows for direct routing in open cable trays, reducing overall installation costs while maintaining physical signal path integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eMechanical Installation \u0026amp; Grounding Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Length Match Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrior to mounting, verify that the total combined length of your proximity probe and this extension cable matches the calibration rating of your Proximitor sensor (e.g., a 1.0 m probe plus this 8.0 m cable equals a 9.0 m calibrated system). Using a 5.0 m Proximitor with this combination will cause immediate calibration and measurement faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintaining Minimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the stainless steel armor offers superior physical defense, do not bend the cable tighter than a minimum radius of 25.4 mm (1.0 inch). Kinking or over-bending the armor can distort the internal coaxial geometry, altering the system's impedance and degrading the vibration signal accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connection Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the pre-installed connector protector sleeve at the probe-to-extension cable junction. Ensure the ClickLoc connectors are clean, completely dry, and fully clicked into place before sliding the protector over the connection. Never allow the unshielded connector metal to touch the machine casing, as this creates ground loops that introduce massive electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323529067,"sku":"330130-080-13-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-080-13-cn-xwc4nvk2rdu_a34b171a-5a4b-4e20-a224-444f34bc7a77.jpg?v=1765521234"},{"product_id":"330930-065-05-cn-bently-nevada-3300-xl-nsv-proximity-extension-cable","title":"330930-065-05-CN Bently Nevada 3300 XL NSv Proximity Extension Cable","description":"\u003ch3 class=\"\"\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN \u003c\/strong\u003e\u003cspan class=\"\"\u003eis a high-performance extension cable designed specifically for the Bently Nevada 3300 XL NSv (Narrow Side view) Proximity Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specialized cable serves as the critical signal link between the proximity probe and the Proximitor Sensor,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaintaining impedance matching and signal integrity in demanding industrial environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for applications with tight spatial constraints where standard proximity probes cannot be used,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as small centrifugal compressors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epumps,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand motors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy ensuring precise transmission of eddy-current signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis cable facilitates accurate vibration and position monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edirectly contributing to the mechanical health and safety of high-speed rotating assets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis configured according to the following technical specifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e330930\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBase model for the 3300 XL NSv Extension Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e065 (Cable Length Option)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e6.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 meters (21.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 feet).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis length is specifically calibrated to match the system's electrical requirements for a total 7.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter or 9.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter system length.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e05 (Connector and Cable Option)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with heavy-duty stainless steel armor for superior mechanical protection; supplied without FEP jacket; includes factory-installed connector protectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCN (Agency Approval Option)\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCertified for use in hazardous areas with ATEX\/IECEx and Chinese NEPSI markings,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring compliance with global and regional safety standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-065-05-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL NSv Proximity System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 g\/m (0.5 oz\/ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (AISI 302\/304)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area Marking\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX, IECEx, NEPSI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan this extension cable be used with a standard 3300 XL 8mm probe?\u003c\/strong\u003e\u003cspan class=\"\"\u003eNo.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis designed exclusively for the NSv system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUsing it with standard 5mm or 8mm systems will result in incorrect impedance matching and significant measurement errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the purpose of the stainless steel armor (Option 05)?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe armor provides high physical durability against crushing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eabrasion,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand rodent damage in industrial environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esince this version lacks the FEP jacket,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit is best suited for environments where chemical exposure is not the primary concern.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAre the connector protectors removable?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe connector protectors are designed to prevent the connectors from being damaged or contaminated during the \"pulling\" process through conduit.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThey should be used during installation and can be removed for final mating.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Integrity and Connector Maintenance\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe coaxial connectors on the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330930-065-05-CN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eare sensitive to moisture and oil.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAlways ensure connectors are clean and dry before mating.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWe recommend using a torque wrench specifically designed for proximity system connectors (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e45 N-m or 4 in-lb) to prevent over-tightening,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich can deform the center pin and lead to intermittent signal loss or \"spiking.\u003c\/span\u003e\u003cspan class=\"\"\u003e\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInstallation in Hazardous Areas\u003c\/strong\u003e\u003cspan class=\"\"\u003eAs a NEPSI and ATEX certified component,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis cable must be installed in accordance with the specific \"Conditions of Safe Use\" outlined in the certification documentation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the stainless steel armor is properly bonded to the machine ground at the bulkhead or junction box to prevent electrostatic buildup or potential differences in hazardous atmospheres.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCable Routing Limits\u003c\/strong\u003e\u003cspan class=\"\"\u003eWhile the stainless steel armor is robust,\u003c\/span\u003e\u003cspan\u003e observe the minimum bend radius of 25.\u003c\/span\u003e\u003cspan\u003e4 mm (1.\u003c\/span\u003e\u003cspan\u003e0 inch).\u003c\/span\u003e\u003cspan\u003e Kinking the cable will change its coaxial capacitance,\u003c\/span\u003e\u003cspan\u003e permanently altering the calibration of the entire proximity system and necessitating replacement of the cable to restore accuracy.\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324282731,"sku":"330930-065-05-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-065-05-cn-zw40ihoeo2y_07b1c5aa-d20e-4c0e-9876-b628f171d888.jpg?v=1765521259"},{"product_id":"bently-nevada-330130-045-13-00-3300-xl-extension-cable","title":"Bently Nevada 330130-045-13-00 3300 XL Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-045-13-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized extension cable for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity transducer system. This cable acts as the vital link between a 3300 XL proximity probe and a 3300 XL Proximitor® Sensor. Engineered for extreme industrial environments, this specific model features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFluidLoc® technology\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent moisture or oil from wicking through the cable and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estainless steel armor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect against mechanical crushing and abrasion.\u003c\/p\u003e\n\u003cp\u003eIn a standard vibration monitoring loop, the extension cable must be matched to the probe length to achieve a \"Total System Length\" (typically 5.0 or 9.0 meters). This ensures the electrical circuit is perfectly tuned for the eddy current measurement used to monitor shaft vibration and position.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe part number breakdown identifies the protective features and physical dimensions:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Length (045):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.5 metres (14.8 feet). When paired with a 0.5-meter probe, this creates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFluidLoc® Cable:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a patented internal design that blocks the \"wicking\" effect, ensuring that if one end of the cable is exposed to oil or pressurized fluids, the liquid cannot travel through the cable into the Proximitor housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArmored Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable is encased in flexible, interlocking stainless steel armor, providing superior crush resistance in areas with heavy foot traffic or sharp-edged machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protectors (13):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes clear, removable sleeves at the connection points to prevent the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClickLoc™\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectors from vibrating loose and to provide environmental sealing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Isolated Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard coaxial construction optimized for high-frequency signal transmission with minimal loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-045-13-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ω Coaxial (FluidLoc®)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 Metres\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Coaxial ClickLoc™\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in) for armored cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is FluidLoc® important for my installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn many turbines and gearboxes, the probe end is submerged in lubricating oil. Standard cables can act like a \"straw,\" allowing oil to seep through the internal gaps of the cable and eventually leak into the control cabinet.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFluidLoc®\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseals the internal cable structure to prevent this.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I cut this cable to a shorter length if it's too long?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNo.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3300 XL system is a tuned resonant circuit. The capacitance and inductance of the cable are calculated into the vibration reading. Cutting the cable will change the impedance, causing significant errors in the vibration measurement or making the system completely non-functional.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable require a specific Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, this cable must be used with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Proximitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfigured for a 5.0-meter system. Using it with a 9.0-meter Proximitor will result in incorrect scale factors and inaccurate data.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen joining the probe to the extension cable, ensure the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClickLoc™\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectors \"click\" into place. Slide the connector protector over the junction to ensure it remains locked despite machine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAvoid Sharp Bends:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough armored, the cable has a minimum bend radius. Forcing a sharp 90-degree bend can damage the internal coaxial dielectric, leading to \"noisy\" vibration signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit and Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the armor provides protection, the cable should still be supported by conduit or cable trays where possible. Avoid zip-tying the cable directly to high-voltage power lines to prevent electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3300 XL system typically expects a single-point ground at the Proximitor end. Ensure the armor is not inadvertently touching other grounded metal surfaces that could create a ground loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324643179,"sku":"330130-045-13-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-045-00-00-3300-xl-extension-cable-pqecofsscc3_49572228-e4ba-466b-8ebe-13aae2d74749.jpg?v=1765449301"},{"product_id":"bently-nevada-330930-045-01-cn-3300-nsv-armored-extension-cable","title":"Bently Nevada 330930-045-01-CN 3300 NSv Armored Extension Cable","description":"\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\nThe \u003cstrong\u003e330930-045-01-CN\u003c\/strong\u003e is a high-performance extension cable specifically engineered for the Bently Nevada 3300 NSv (Narrow Side view) proximity transducer system. \nThe NSv series is the industry standard for vibration and position monitoring in confined spaces or on small-diameter shafts where standard probes would suffer from side-viewing interference. \nThis cable provides the critical electrical link between the NSv probe and the Proximitor sensor, maintaining the precision impedance required for accurate eddy-current measurements. \nIdeal for aero-derivative gas turbines, centrifugal compressors, and small steam turbines, the \u003cstrong\u003e330930-045-01-CN\u003c\/strong\u003e features ruggedized armoring and chemical protection, ensuring maximum signal integrity and machine uptime in the most volatile industrial environments.\n\u003c\/p\u003e\n\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003e\nThe model \u003cstrong\u003e330930-045-01-CN\u003c\/strong\u003e is configured with specific mechanical and regional protection layers:\n\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330930\u003c\/strong\u003e: 3300 NSv Extension Cable series.\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e045\u003c\/strong\u003e: Cable Length Option – 4.5 meters (14.8 feet).\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: Connector and Cable Option – Equipped with stainless steel armor for mechanical protection, plus an external FEP (Fluoroethylenepropylene) jacket for superior chemical and moisture resistance.\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCN\u003c\/strong\u003e: Agency Approval Option – Country-specific approvals for the China market, ensuring compliance with local hazardous area and industrial safety regulations.\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930-045-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial with FEP insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel armor with FEP outer jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated miniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 inch) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eHow does the FEP jacket (Option 01) differ from the standard armored cable?\u003c\/strong\u003e\u003cbr\u003e\nWhile the stainless steel armor provides mechanical protection against crushing, the FEP jacket provides an additional layer of protection against environmental contaminants. \nIt prevents corrosive fluids, moisture, and oils from penetrating the armor braids and reaching the internal coaxial cable, significantly extending the cable's lifespan in harsh chemical environments.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eCan I use this 330930 cable with a 3300 XL 8 mm probe?\u003c\/strong\u003e\u003cbr\u003e\nNo. The 3300 NSv system is electrically distinct from the 3300 XL series. \nThe NSv cable is tuned to the specific inductance and capacitance requirements of the NSv probe and Proximitor. \nInterchanging them will lead to incorrect vibration readings and potential \"Not OK\" status at the monitoring rack.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eWhat is the importance of the total system length?\u003c\/strong\u003e\u003cbr\u003e\nBently Nevada proximity systems are calibrated as a complete loop (Probe + Extension Cable). \nA 4.5-meter cable is typically paired with a 0.5-meter probe to achieve a 5.0-meter system length. \nUsing a cable length that does not match the Proximitor sensor's calibration will cause a significant scale factor error.\n\u003c\/p\u003e\n\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e \nThe FEP jacket is highly resistant to most industrial solvents and fuels. \nEnsure the jacket is inspected for tears during installation. Any breach in the FEP layer can allow fluids to wick into the armor, potentially leading to signal degradation or ground faults.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e \nAlways use the ClickLoc connector system properly. \nWhen mating the probe lead to the extension cable, you should feel a distinct \"click\" indicating the gold-plated pins are fully seated. \nFailure to secure the connection can lead to intermittent signal loss, especially in high-vibration machinery.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocols:\u003c\/strong\u003e \nThe stainless steel armor should be electrically isolated from the machine casing and only grounded at the Proximitor sensor end. \nThis prevents ground loops, which are a common source of electrical noise in vibration signals.\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eMechanical Routing:\u003c\/strong\u003e \nAvoid routing the armored cable across sharp metal edges or in areas where it may be pinched by moving machinery components. \nDespite the armor, the internal coaxial dielectric can be crushed, which changes the cable's impedance and invalidates the sensor calibration.\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324970859,"sku":"330930-045-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-045-01-cn-pnahjolvj55_c106988e-90ec-4b4d-ac75-037d9e906d2e.jpg?v=1765521282"},{"product_id":"bently-nevada-330130-045-13-cn-3300-xl-extension-cable","title":"Bently Nevada 330130-045-13-CN 3300 XL Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-045-13-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a premium 3300 XL series extension cable engineered by Bently Nevada to maintain signal integrity in the most demanding industrial environments.\u003cspan\u003e \u003c\/span\u003eThis cable serves as the critical link between a 3300 XL proximity probe and a Proximitor sensor,\u003cspan\u003e \u003c\/span\u003eensuring the transmission of high-frequency eddy-current data without interference.\u003cspan\u003e \u003c\/span\u003eUtilizing FluidLoc technology and integrated armor,\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e330130-045-13-CN\u003cspan\u003e \u003c\/span\u003eis purpose-built for applications in steam turbines,\u003cspan\u003e \u003c\/span\u003ecooling towers,\u003cspan\u003e \u003c\/span\u003eand centrifugal pumps where exposure to moisture,\u003cspan\u003e \u003c\/span\u003eoil,\u003cspan\u003e \u003c\/span\u003eor physical abrasion is a constant risk.\u003cspan\u003e \u003c\/span\u003eBy providing a stable electrical path,\u003cspan\u003e \u003c\/span\u003eit ensures the accuracy of vibration and position monitoring,\u003cspan\u003e \u003c\/span\u003eallowing for precise predictive maintenance and the prevention of unplanned machinery outages.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e330130-045-13-CN\u003cspan\u003e \u003c\/span\u003esignifies a high-durability configuration designed for hazardous and wet locations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330130:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL Extension Cable series (Standard 8 mm and 5 mm compatibility).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e045:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCable Length Option - 4.5 meters (14.8 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e13:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnector Protector and Cable Option - Features FluidLoc cable construction to prevent moisture wicking and stainless steel armor for mechanical protection,\u003cspan\u003e \u003c\/span\u003eincluding pre-installed connector protectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAgency Approval Option - Country-specific approvals for the China market,\u003cspan\u003e \u003c\/span\u003ecertifying the cable for use in regulated hazardous industrial zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-045-13-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial with FluidLoc technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Protection\u003c\/td\u003e\n\u003ctd\u003eStainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eGold-plated miniature coaxial with ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e4.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg (approx. cable only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes the FluidLoc cable (Option 13) different from standard armored cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFluidLoc technology is specifically designed to prevent \"wicking.\" In standard cables,\u003cspan\u003e \u003c\/span\u003eif the jacket is cut,\u003cspan\u003e \u003c\/span\u003efluids like oil or water can travel through the interior of the cable and reach the Proximitor sensor or probe.\u003cspan\u003e \u003c\/span\u003eFluidLoc prevents this internal migration,\u003cspan\u003e \u003c\/span\u003eprotecting the sensitive electronic junctions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this extension cable compatible with 5 mm 3300 XL probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes,\u003cspan\u003e \u003c\/span\u003ethe 330130 series extension cables are the standard connection for both 3300 XL 8 mm and 5 mm proximity transducer systems.\u003cspan\u003e \u003c\/span\u003eEnsure your total system length (probe + extension cable) matches the Proximitor sensor's calibration (typically 5.0 or 9.0 meters).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the armor provide electrical shielding?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe primary purpose of the stainless steel armor is mechanical protection against crushing or cutting.\u003cspan\u003e \u003c\/span\u003eWhile it provides some additional electromagnetic shielding,\u003cspan\u003e \u003c\/span\u003ethe internal coaxial cable is already highly shielded.\u003cspan\u003e \u003c\/span\u003eThe armor should be grounded only at the Proximitor end to avoid ground loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Protector Usage:\u003cspan\u003e \u003c\/span\u003eThe 13 option includes connector protectors.\u003cspan\u003e \u003c\/span\u003eThese are essential for preventing the coaxial connectors from loosening due to machine vibration and for keeping the connection free of environmental contaminants.\u003cspan\u003e \u003c\/span\u003eEnsure they are threaded tightly over the connection point between the probe lead and the extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal System Length Matching:\u003cspan\u003e \u003c\/span\u003eThis 4.5-meter cable is typically paired with a 0.5-meter probe lead to create a 5.0-meter system.\u003cspan\u003e \u003c\/span\u003eIf your Proximitor sensor is calibrated for a 9.0-meter system,\u003cspan\u003e \u003c\/span\u003eusing this cable without additional length will result in significant measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius Constraints:\u003cspan\u003e \u003c\/span\u003eEven with stainless steel armor,\u003cspan\u003e \u003c\/span\u003ethe cable must not be bent tighter than a 25.4 mm (1.0 inch) radius.\u003cspan\u003e \u003c\/span\u003eOver-bending can alter the cable's capacitance and impedance,\u003cspan\u003e \u003c\/span\u003eleading to signal distortion and incorrect vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmor Integrity:\u003cspan\u003e \u003c\/span\u003eInspect the armor for any fraying or sharp breaks during installation.\u003cspan\u003e \u003c\/span\u003eIf the armor is compromised,\u003cspan\u003e \u003c\/span\u003eit can cut into the FEP jacket of the internal cable,\u003cspan\u003e \u003c\/span\u003epotentially grounding the signal and triggering a \"Not OK\" status on the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325003627,"sku":"330130-045-13-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-045-13-cn-e4rsza1xrgs_62c87da1-9d31-4cde-be78-e99a6740bb99.jpg?v=1765521282"},{"product_id":"bently-nevada-330930-065-02-cn-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-02-CN 3300 NSv Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 3300 NSv (Narrow Side view) extension cable designed by Bently Nevada for high-precision proximity transducer systems. The NSv series is specifically engineered for applications where structural constraints or small shaft diameters require a sensor with a narrow magnetic field. This cable acts as the vital signal link between the proximity probe and the Proximitor sensor, maintaining the tuned electrical impedance necessary for accurate vibration and position monitoring. Commonly deployed in centrifugal compressors, small steam turbines, and aero-derivative gas turbines, the 330930-065-02-CN ensures that high-frequency eddy-current signals are transmitted with minimal attenuation, directly contributing to machine safety and the prevention of costly unplanned outages.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model 330930-065-02-CN is defined by its mechanical protection and regional certification options:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330930:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 NSv Extension Cable series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e065:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCable Length Option - 6.5 meters (21.3 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eConnector and Cable Option - Equipped with stainless steel armor for superior mechanical protection, without an external FEP jacket over the armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAgency Approval Option - Country-specific approvals for the China market, ensuring compliance with local industrial safety and hazardous area standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330930-065-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Material\u003c\/td\u003e\n\u003ctd\u003eAISI 302\/304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e6.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg (Cable only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this NSv extension cable with a standard 3300 XL 8 mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 3300 NSv system has different electrical characteristics (inductance and capacitance) compared to the 3300 XL series. Mixing NSv cables with XL probes will result in incorrect scale factors and significant measurement errors. Always match the cable series to the probe and Proximitor type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the stainless steel armor (Option 02)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stainless steel armor provides robust protection against physical damage such as crushing, abrasion, or accidental cutting in harsh industrial environments. It is ideal for installations where the cable is exposed rather than housed in a dedicated conduit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the total system length affect calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBently Nevada proximity systems are tuned to specific total electrical lengths (typically 5 or 9 meters). This 6.5-meter cable must be combined with a probe of the correct lead length to reach the total system length required by the Proximitor sensor. Failure to match these lengths will compromise calibration accuracy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Handling: The miniature coaxial connectors are precision components. Use a connector protector if the junction is located in an area exposed to oil or moisture. Ensure the \"ClickLoc\" mechanism is fully engaged; you should feel a tactile click when the connection is secure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Bend Radius: Even with stainless steel armor, do not exceed the minimum bend radius of 25.4 mm (1.0 inch). Sharp bends can damage the internal coaxial dielectric, leading to signal noise or a \"Not OK\" status on the monitoring rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmor Grounding: Ensure the stainless steel armor is not inadvertently grounded at multiple points, as this can create ground loops that introduce electrical interference into the vibration signal. The system is typically grounded only at the Proximitor sensor end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmor vs. Jacket: Since this model (Option 02) does not have an FEP jacket over the armor, avoid routing the cable through areas where corrosive chemicals could penetrate the stainless steel braid and attack the internal cable insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325101931,"sku":"330930-065-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330930-065-02-cn-jppv3jwe252_edf75e16-33ff-4f5a-aef8-43b0dc3b4938.jpg?v=1765521285"},{"product_id":"330190-045-01-00-bently-nevada-3300-xl-etr-extension-cable-4-5m-armored","title":"330190-045-01-00 Bently Nevada 3300 XL ETR Extension Cable (4.5m Armored)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330190-045-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical link in the Bently Nevada 3300 XL Proximitor Sensor System. Engineered specifically for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExtended Temperature Range (ETR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments, this extension cable maintains signal integrity where standard cables fail. It facilitates high-precision, non-contact measurements of vibration and axial position in large-scale rotating machinery, including steam turbines, centrifugal compressors, and industrial pumps.\u003c\/p\u003e\n\u003cp\u003eBy utilizing advanced fluoropolymer insulation and a robust mechanical design, this cable ensures the eddy current signal travels from the probe to the Proximitor with minimal attenuation. Its presence within a Machinery Protection System (MPS) guarantees that operators receive real-time, laboratory-grade data to prevent catastrophic equipment failure and optimize maintenance schedules.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330190-045-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a specific alphanumeric logic that defines its physical and mechanical properties:\u003c\/p\u003e\n\u003ch3\u003e330190 - Product Series\u003c\/h3\u003e\n\u003cp\u003eThis designates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Extended Temperature Range (ETR) Extension Cable\u003c\/strong\u003e. It is fully compatible with 3300 XL 8mm probes and Proximitor sensors.\u003c\/p\u003e\n\u003ch3\u003e045 - Cable Length Option\u003c\/h3\u003e\n\u003cp\u003eThis suffix specifies a total length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4.5 meters (14.8 feet)\u003c\/strong\u003e. System accuracy depends on maintaining a total length (probe + extension cable) of either 5.0 or 9.0 meters; this 4.5m cable typically pairs with a 0.5m probe to reach a 5-meter system balance.\u003c\/p\u003e\n\u003ch3\u003e01 - Cable Option\u003c\/h3\u003e\n\u003cp\u003eThe \"01\" designation confirms this is an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eArmored Cable\u003c\/strong\u003e. The stainless steel TFE-jacketed armor provides superior crush resistance and protects the internal coaxial core from mechanical damage in harsh industrial pathways.\u003c\/p\u003e\n\u003ch3\u003e00 - Agency Approval Option\u003c\/h3\u003e\n\u003cp\u003eThis indicates that\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Specific Agency Approvals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(such as ATEX\/IECEx) are required for this particular unit, making it ideal for general-purpose industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8mm Proximity Transducer System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +260°C (-60°F to +500°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 Meters (14.8 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ω Coaxial, Armored (304 Stainless Steel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated Brass \/ Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in) for armored sections\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 Kg (0.66 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDurability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluid resistant, high-moisture tolerance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eProper installation ensures the longevity of the vibration monitoring loop. Follow these engineering best practices:\u003c\/p\u003e\n\u003ch3\u003eConnector Protection\u003c\/h3\u003e\n\u003cp\u003eAlways use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econnector protectors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor heat-shrink tubing to seal the connection between the probe and the extension cable. Moisture ingress at the connector junction is the leading cause of \"glitch\" or signal drift in eddy current systems.\u003c\/p\u003e\n\u003ch3\u003eMinimum Bend Radius\u003c\/h3\u003e\n\u003cp\u003eAvoid sharp kinks. While the armored casing provides protection, exceeding the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25.4 mm (1.0 inch) bend radius\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan damage the internal coaxial dielectric, leading to impedance mismatch and calibration errors.\u003c\/p\u003e\n\u003ch3\u003eSignal Calibration (Gap Voltage)\u003c\/h3\u003e\n\u003cp\u003eAfter connecting the 330190-045-01-00 to the probe and Proximitor, verify the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC Gap Voltage\u003c\/strong\u003e. For a standard 3300 XL 8mm system, a voltage of approximately -10 VDC typically represents the center of the linear range (approx. 1.27 mm or 50 mils gap).\u003c\/p\u003e\n\u003ch3\u003eRouting Precautions\u003c\/h3\u003e\n\u003cp\u003eIsolate the extension cable from high-voltage conduits. Use dedicated grounded metal trays to prevent Electromagnetic Interference (EMI) from distorting the vibration waveform.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330190-045-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrives where standard PVC or FEP cables degrade. Its ETR rating allows for continuous operation near turbine casings and exhaust hoods where temperatures frequently exceed 150°C.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless TSI Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis cable integrates perfectly with Bently Nevada 3500 and 2300 Vibration Monitoring racks, ensuring the transducer system maintains its 7.87 V\/mm (200 mV\/mil) sensitivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 304 stainless steel armor eliminates the need for external conduit in many applications, reducing installation costs while protecting against abrasive dust and accidental impact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced insulation materials prevent capacitance changes during temperature fluctuations, ensuring the vibration data remains accurate from cold start-up to peak operating load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this 4.5m cable with a 1.0m probe in a 5-meter system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. A 5-meter system requires a total length of 5.0 meters. Since this cable is 4.5 meters, it must be paired with a 0.5-meter probe. Pairing it with a 1.0-meter probe would create a 5.5-meter mismatch, causing significant calibration errors in the Proximitor output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the benefit of the \"ETR\" version over the standard 3300 XL cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The ETR (Extended Temperature Range) version uses specialized dielectric materials that withstand up to 260°C. Standard cables are typically rated for lower thresholds. Use the ETR version for sensors located near steam paths or high-heat zones.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the armored option (01) affect the electrical performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No. The armor is a mechanical layer. The internal electrical characteristics remain consistent with the 3300 XL standard, providing the same impedance and frequency response required for high-accuracy vibration monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is this cable backward compatible with the older 3300 8mm (non-XL) systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: While physically compatible in many cases, Bently Nevada recommends using 3300 XL components together to ensure the system meets the published API 670 standards for linearity and accuracy. Mixing XL and non-XL components may result in a non-linear scale factor.\u003c\/p\u003e\n\u003ch2\u003e\u003c\/h2\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325593451,"sku":"330190-045-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330190-045-01-00-uzxo5kqfrix_a5ab24cd-dd36-4dfa-bbf7-96f6bc997297.jpg?v=1765521300"},{"product_id":"43501-01-04-01-bently-nevada-low-pressure-cable-seal-1-2-14-npt","title":"43501-01-04-01 Bently Nevada Low Pressure Cable Seal (1\/2-14 NPT)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e43501-01-04-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLow Pressure Cable Seal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered by Bently Nevada to provide a robust environmental barrier between a machine's internal housing and the external atmosphere. This component is essential for installations where proximity probe cables must exit a bearing housing or gear box while preventing the leakage of oil mist, splash, or low-pressure gases.\u003c\/p\u003e\n\u003cp\u003eUnlike standard industrial glands, the 43501 series is designed specifically to protect the delicate coaxial cables of the 3300 XL and 7200 series transducer systems. It maintains a tight seal around the cable outer jacket without compressing the dielectric layer, which would otherwise change the cable's capacitance and ruin the sensor's calibration. This unit ensures that your machine's lubrication remains contained while protecting the monitoring system from environmental contamination.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e43501-01-04-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a modular hardware stack to accommodate multiple cables through a single penetration point.\u003c\/p\u003e\n\u003ch3\u003eHigh Pressure Side Thread (01)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation specifies a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1\/2-14 NPT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethread for the high-pressure (machine) side. This standard tapered thread ensures a leak-proof connection when installed into the machine casing or a dedicated seal housing.\u003c\/p\u003e\n\u003ch3\u003eCable Grommet and Washer (04)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption is a multi-port configuration. The internal grommet is designed to accommodate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eup to 4 cables\u003c\/strong\u003e. To maintain sealing integrity, only one hole is fully punched at the factory, while the remaining three are partially pre-drilled. This allows the installer to punch through only the number of ports required for the specific application (e.g., two X-Y radial probes), keeping the unused ports hermetically sealed.\u003c\/p\u003e\n\u003ch3\u003eLow Pressure Side Thread (01)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignifies a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1\/2-14 NPT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethread on the low-pressure (atmospheric) side. This allows for the direct connection of rigid or flexible conduit, protecting the cables as they transit to the Proximitor® junction box.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChrome-plated Steel or Stainless Steel components\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGrommet Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOil-resistant Neoprene or Fluorocarbon\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size (Both Sides)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-14 NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Cable Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Coaxial Cables (standard 7200\/3300 XL)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 345 kPa (50 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-34°C to +121°C (-30°F to +250°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 Kg (Robust industrial packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e43501 Cable Seal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers mechanical advantages that generic cable glands cannot match:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePreservation of Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal grommet provides a \"soft\" seal that grips the cable without deforming the coaxial geometry. This prevents impedance changes that lead to false vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Multi-Cable Entry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy allowing up to four cables through a single 1\/2-inch NPT hole, the 43501 reduces the number of penetrations required in the machine casing, maintaining structural integrity and reducing potential leak points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNPT to NPT Bridge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-threaded design acts as a structural bridge, allowing for a seamless, sealed transition from the machine wall directly into a conduit system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cp\u003eSuccessful sealing requires careful preparation of the grommet and cable routing.\u003c\/p\u003e\n\u003ch3\u003eGrommet Preparation\u003c\/h3\u003e\n\u003cp\u003eFor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egrommet, only punch through the holes you intend to use. Use a sharp, clean punch to avoid tearing the neoprene. If you accidentally punch an extra hole, it must be plugged with a dummy cable or a specialized sealing plug to prevent oil bypass.\u003c\/p\u003e\n\u003ch3\u003eAssembly Sequence\u003c\/h3\u003e\n\u003cp\u003eSlide the compression nut, washer, and grommet onto the cables before the connectors are attached (if using field-terminable cables). If the connectors are already installed, ensure they can pass through the 1\/2-inch NPT opening. Tighten the compression nut until the grommet visibly expands around the cables; do not over-torque, as this can crush the coaxial dielectric.\u003c\/p\u003e\n\u003ch3\u003eThread Sealing\u003c\/h3\u003e\n\u003cp\u003eApply a high-quality thread sealant (such as PTFE tape or pipe dope) to the NPT threads before installation into the machine. Ensure no sealant enters the internal chamber of the seal where it could interfere with the grommet's seating.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the maximum pressure this \"Low Pressure\" seal can handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The 43501 series is rated for pressures up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e345 kPa (50 psi)\u003c\/strong\u003e. For applications involving higher pressures (such as high-pressure hydrogen-cooled generators), you must use the Bently Nevada 16622 High Pressure Oil Seal series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I use this for cables other than Bently Nevada proximity cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, provided the cable diameter is similar to standard 7200 or 3300 XL coaxial cables (typically approx. 2.5 mm to 3.8 mm). However, the grommet is specifically contoured for Bently Nevada cable dimensions to ensure a certified seal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why is the shipping weight 3 kg for a small cable seal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The 43501 is a heavy-duty industrial fitting. To protect the NPT threads and the internal precision-ground washers during transit, it is shipped in reinforced packaging. The 3 kg weight reflects the robust nature of the hardware and its protective box.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the \"04\" grommet compatible with armored cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Generally, no. The 43501 is designed for standard (unarmored) coaxial cables. Armored cables typically require a larger seal or the removal of the armor before passing through the seal, with the armor terminated at the conduit fitting.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325691755,"sku":"43501-01-04-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/43501-01-04-01-bmxgznn1gmu_81356fe6-ef34-4aa0-bc10-23fecc823f41.jpg?v=1765521304"},{"product_id":"330730-080-00-bently-nevada-3300-xl-11mm-extension-cable-8-0m","title":"330730-080-00 Bently Nevada 3300 XL 11mm Extension Cable (8.0m)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730-080-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-precision signal conduit for the Bently Nevada 3300 XL 11mm Proximity Transducer System. This 8.0-meter extension cable bridges the gap between the 11mm probe and the Proximitor® Sensor, maintaining signal integrity over long distances in demanding industrial environments. While 8mm systems handle standard machinery, the 11mm system—and this specific cable—supports applications requiring a wider linear range (up to 4.0 mm \/ 160 mils), such as large steam turbines and axial thrust measurements.\u003c\/p\u003e\n\u003cp\u003eEngineered with advanced fluoropolymer insulation, the 330730-080-00 prevents signal attenuation and electromagnetic interference (EMI). Its low-capacitance design ensures that the high-frequency eddy current oscillations remain stable, providing the monitoring system with a clean, accurate representation of shaft position or vibration. Whether installed in a cable tray or a protective conduit, this cable withstands the extreme thermal cycling typical of power generation and petrochemical facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe model\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730-080-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a strict physical calibration logic to ensure the total system impedance remains within Bently Nevada's performance specifications.\u003c\/p\u003e\n\u003ch3\u003eCable Length (080)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e080\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption designates a total length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8.0 meters (26.2 feet)\u003c\/strong\u003e. In proximity systems, cable length is not arbitrary; the Proximitor® is calibrated for a specific total system length (typically 9.0 meters). When paired with a 1.0-meter probe, this 8.0-meter cable completes the electrical loop perfectly.\u003c\/p\u003e\n\u003ch3\u003eConnector and Cable Option (00)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStandard coaxial cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration without additional stainless steel armor. This version offers maximum flexibility for routing through tight conduits or internal machine housings while utilizing the high-performance FEP (Fluorinated Ethylene Propylene) outer jacket for chemical resistance.\u003c\/p\u003e\n\u003ch3\u003eHigh-Precision Capacitance\u003c\/h3\u003e\n\u003cp\u003eWith a typical capacitance of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e69.9 pF\/m\u003c\/strong\u003e, this cable minimizes phase shifts and signal lag. This electrical precision is what allows Bently Nevada systems to maintain a consistent 3.94 V\/mm (100 mV\/mil) sensitivity across the entire 11mm system's extended range.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 11 mm Proximity System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 Meters (26.2 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +351°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eJacket Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFEP (Fluorinated Ethylene Propylene)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated ClickLoc™ Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 inch)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.36 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eextension cables provide a significant reliability edge for critical asset protection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClickLoc™ Technology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable features gold-plated ClickLoc™ connectors that snap together securely. This \"click\" provides tactile confirmation of a solid connection, preventing the signal \"spiking\" often caused by loose threaded connectors in high-vibration areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Temperature Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FEP jacket remains flexible at -51°C and structurally sound up to +177°C, allowing the cable to be routed near steam lines or in arctic environments without cracking or melting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe outer insulation resists degradation from synthetic lubricants, hydraulic fluids, and most industrial solvents, ensuring a service life measured in decades rather than years.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cp\u003eA proximity system's accuracy is only as good as its cable connections. Follow these engineering best practices:\u003c\/p\u003e\n\u003ch3\u003eTotal System Length Matching\u003c\/h3\u003e\n\u003cp\u003eAlways verify that your total cable length (Probe + Extension) matches the \"System Length\" printed on your Proximitor® Sensor. For this 8.0m cable, you must use a 1.0m probe to reach the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0m system calibration\u003c\/strong\u003e. Mixing 5m and 9m components will cause severe scale factor errors.\u003c\/p\u003e\n\u003ch3\u003eConnector Protection\u003c\/h3\u003e\n\u003cp\u003eWhile the ClickLoc™ connector is robust, it is not waterproof. In environments with high moisture or oil mist, always use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConnector Protectors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(clear plastic sleeves or heat-shrink) to prevent fluid ingress into the coaxial junction.\u003c\/p\u003e\n\u003ch3\u003eProper Routing\u003c\/h3\u003e\n\u003cp\u003eAvoid routing the 330730-080-00 parallel to high-voltage AC power lines. If cross-talk is suspected, ensure the cable is placed in a grounded metal conduit. Never use zip-ties so tight that they deform the cable jacket, as this changes the internal capacitance and ruins the calibration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this 11mm extension cable with an 8mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The 11mm system uses a larger probe tip and a different Proximitor® calibration. The 330730 cable is specifically tuned for the electrical characteristics of the 11mm series. Using it with 8mm components will result in inaccurate readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What happens if I cut the cable to a shorter length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNever cut or splice a proximity extension cable.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe length is an integral part of the tuned circuit. Shortening the cable will change the capacitance, leading to a massive error in the gap voltage and vibration sensitivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is this cable available with stainless steel armor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. While the \"00\" option is standard, the 330730 series can be ordered with \"01\" or \"02\" options for flexible AISI 302 SST armor if the cable will be exposed to physical abrasion or flying debris.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How do I identify a 3300 XL 11mm cable compared to an 8mm cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Most 3300 XL cables look similar, but the 11mm series often features a larger connector body or specific color-coded tags. Always verify the part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the cable's identification label before installation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325757291,"sku":"330730-080-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330730-080-00-wyzpu1y5o5d_b59f7634-1c85-4e60-b4d4-529eb2717eb0.jpg?v=1765521307"}],"url":"https:\/\/www.plcprotech.com\/collections\/cables.oembed?page=5","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}