{"title":"Cables","description":"\u003cp\u003eIndustrial Cables are engineered to maintain signal integrity and power distribution across complex automation networks. The architecture involves high-purity conductors, multi-layer shielding to mitigate EMI\/RFI, and durable outer jackets resistant to chemicals and abrasion. Technical characteristics include low capacitance for high-speed data transmission and standardized connectors for seamless integration with \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/i-o-modules\"\u003eI\/O modules\u003c\/a\u003e and \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/hmi-panels\"\u003eHMI panels\u003c\/a\u003e. Functionally, these cables provide the physical link for both analog signals and digital protocols, ensuring that critical data from \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/probes\"\u003eprobes\u003c\/a\u003e and sensors reaches the controller without attenuation or noise interference, thereby maintaining the accuracy of the entire control loop.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-330930-065-01-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-01-05 3300 NSv Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rugged, high-precision proximity transducer link engineered for the industry-leading\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 NSv\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity transducer system. Functioning as a high-integrity signal transmission path, this armored coaxial extension cable connects the specialized NSv proximity probe to the matching Proximitor sensor unit. Extreme operational environments—including oil and gas refineries, petrochemical processing plants, and critical aeroderivative gas turbine installations—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto deliver high-fidelity eddy current telemetry. The module maintains stable impedance profiles when routed through harsh confined spaces to track tight machinery clearances and small-shaft vibrations. By safeguarding low-voltage displacement signals from external radio frequency interference (RFI) and mechanical crushing, this cable guarantees precise data delivery. This continuous monitoring enables safety platforms to stop assets before catastrophic shaft misalignment or bearing wipe happens, effectively eliminating unprogrammed facility downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe ordering structure of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefines its exact mechanical shielding, transmission distance, and hazardous area safety compliance through a fixed modification format:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330930 (Base Model):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the 3300 NSv Coaxial Extension Cable platform tailored for narrow-gap and small-target proximity applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e065 (Cable Length Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfirms an exact physical cable length of 6.5 meters (21.3 feet), calibrated to specific electrical capacitance limits required by the driver module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01 (Connector Protector and Cable Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies an integrated flexible AISI 302 stainless steel armor sleeve outfitted with a high-durability Fluorinated Ethylene Propylene (FEP) outer jacket for maximum chemical and abrasion protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Agency Approval Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishes Multiple Approvals certification, qualifying the assembly for installation within explosive atmospheres and hazardous zones under ATEX and North American standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Benchmarks\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cstrong\u003eHardware Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cstrong\u003eCertified Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e330930-065-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e3300 NSv Proximity Transducer Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eComponent Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eArmored Coaxial Extension Cable with FEP Jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e6.5 meters (21.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eFlexible AISI 302 Stainless Steel (SST)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eOuter Insulation Jacket\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eFluorinated Ethylene Propylene (FEP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e0.220 Ohm\/meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCoaxial Shield Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e0.066 Ohm\/meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eNominal Cable Capacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e69.9 pF\/meter Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eMass Density (with Armor)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e64 g\/meter (0.7 oz\/foot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003e-51 to +177 deg C Ambient Temperature Limits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.2691%;\"\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.3699%;\"\u003e\u003cspan\u003eMinden, Nevada, USA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Telemetry \u0026amp; Mechanical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy must engineers select an exact cable length like the 6.5-meter option for proximity systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEddy current proximity transducer systems operate on strict total system electrical length calculations. The Proximitor sensor evaluates target distance by reading complex high-frequency impedance, which requires a fixed total capacitance. Modifying, cutting, or splicing the 330930-065-01-05 cable alters this baseline capacitance and corrupts the calibration curves, leading to invalid gap readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific protection does the 01 option provide over baseline unarmored coaxial cords?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 01 suffix configuration wraps the inner coaxial trace in flexible AISI 302 stainless steel armor, shielded further by a smooth FEP outer jacket. This setup prevents mechanical flattening or pinching from heavy cabinet doors and machine components while offering total chemical resistance against synthetic lubricants, hot oils, and corrosive industrial solvents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this extension cable maintain reliable telemetry under sub-zero or high-temperature steam environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The entire assembly utilizes advanced FEP insulation layers rated to maintain tight mechanical flexibility and zero dielectric breakdown across a wide operating thermal envelope of -51 to +177 deg C. This makes it highly stable for sub-sea cryogenic pumps as well as high-temperature gas turbine casing enclosures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection and Terminal Boot Alignment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen joining the extension cable to the proximity probe lead, ensure the miniature coaxial connectors are clean, completely dry, and free of oily residues. Thread the connections together firmly by hand, avoiding excessive torque that can strip the micro-threads. Once joined, slide the factory connector protection sleeve or self-fusing silicone tape enclosure directly over the junction to seal it from moisture infiltration and prevent accidental grounding against nearby machine metalwork.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radii Rules and Conduit Routing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough the stainless steel armor casing provides excellent crushing protection, field technicians must adhere to standard minimum bend radius guidelines during routing. Avoid tight 90-degree creases or sharp structural edges that can kink the inner center conductor or alter the 69.9 pF\/meter nominal capacitance profile. Route the cable through dedicated, oil-tight flexible conduit paths, keeping the sensor wires separated from heavy high-voltage motor or generator supply lines to mitigate electro-magnetic cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Drainage and Structural Stress Relief:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen passing the 330930-065-01-05 cable through low-lying conduit runs, ensure the enclosure layout incorporates proper low-point drainage loops to prevent pooling fluid or condensation buildup from submerging the connections over long operating periods. Provide adequate strain relief loops at both the machine junction box and the 3500 rack entry plate, ensuring machine casing thermal expansion and high-frequency structural vibration do not pull or stress the cable terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515063147,"sku":"330930-065-01-05","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-01-05-nsv-extension-cable-phqpmgfntm3_c63fea36-3bf4-4a33-85bf-91600e72248c.jpg?v=1765440071"},{"product_id":"bently-nevada-330930-065-00-05-3300-xl-nsv-extension-cable","title":"Bently Nevada 330930-065-00-05 3300 XL NSv Extension Cable","description":"\u003ch3\u003e\n    Product Overview\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    The \u003cstrong\u003e330930-065-00-05 (3300 NSv)\u003c\/strong\u003e is a high-performance extension cable specifically engineered for the Bently Nevada 3300 XL NSv (Narrow Side View) Proximity Transducer System. This system is the industry standard for monitoring centrifugal air compressors, refrigeration compressors, and other rotating machinery with extremely tight installation constraints. As a critical link between the NSv probe and the Proximitor Sensor, the \u003cstrong\u003e330930-065-00-05\u003c\/strong\u003e ensures the transmission of high-fidelity displacement signals without impedance mismatch. Its 6.5-meter length is precisely tuned to provide the 200 mV\/mil (7.87 V\/mm) scale factor required for accurate radial vibration and axial position measurements on small-diameter shafts or targets.\n\u003c\/p\u003e\n\n\u003ch3\u003e\n    Suffix Configuration Breakdown\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    According to the official Datasheet 147385, the model \u003cstrong\u003e330930-065-00-05\u003c\/strong\u003e is defined by the following specific engineering options:\n\u003c\/p\u003e\n\n\u003cul class=\"list-paddingleft-2\"\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e065 (Cable Length):\u003c\/strong\u003e 6.5 meters (21.3 feet). This length is typically combined with a 0.5-meter probe to create a 7.0-meter total electrical system.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e00 (Connector Protector and Cable):\u003c\/strong\u003e Standard coaxial cable without stainless steel armor and without connector protectors. This version offers maximum flexibility for routing through dedicated conduit or internal machine housings.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003e05 (Agency Approval):\u003c\/strong\u003e Multiple Approvals (ATEX, IECEx, CSA). This certification allows the cable to be used in intrinsically safe (I.S.) applications within hazardous areas globally.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\n    Technical Specifications\n\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003cthead\u003e\n        \u003ctr class=\"firstRow\"\u003e\n            \u003ctd\u003e\n                \u003cstrong\u003eAttribute\u003c\/strong\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e\n                \u003cstrong\u003eSpecification\u003c\/strong\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e330930-065-00-05\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eBently Nevada\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e3300 XL NSv Proximity Transducer\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eGold-plated Brass ClickLoc\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eJacket Material\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eFluorinated Ethylene Propylene (FEP)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e-52 deg C to +177 deg C (-62 deg F to +351 deg F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e-52 deg C to +177 deg C (-62 deg F to +351 deg F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\n    Engineering FAQs\n\u003c\/h3\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eWhy is the NSv extension cable different from standard 3300 XL cables?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    The NSv series is specifically designed for small targets and tight spaces. The electrical characteristics (inductance and capacitance) of the \u003cstrong\u003e330930\u003c\/strong\u003e cable are tuned to match the NSv probe's smaller coil. Mixing NSv cables with standard 8mm probes will result in incorrect vibration readings.\n\u003c\/p\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eWhat is the purpose of the ClickLoc connector?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    The ClickLoc connector is a patented design that prevents the connection between the probe and extension cable from loosening due to machinery vibration. The gold-plating ensures a low-resistance contact that is essential for maintaining the system's precision scale factor.\n\u003c\/p\u003e\n\n\u003cp\u003e\n    \u003cstrong\u003eCan I install this cable in an environment with turbine oil?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\n    Yes, the FEP jacket is highly resistant to turbine oil and most process chemicals. However, since this specific variant (\u003cstrong\u003e-00\u003c\/strong\u003e) does not have a connector protector, you must ensure the connection point is either sealed with the provided silicone tape or located in a dry area to prevent oil from entering the connector.\n\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003ch3\u003e\n    Field Installation and Maintenance Directives\n\u003c\/h3\u003e\n\n\u003cul class=\"list-paddingleft-2\"\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eConnection Integrity:\u003c\/strong\u003e Before connecting the ClickLoc connectors, verify they are clean and dry. Use a lint-free cloth. Do not use pliers to tighten the connectors; they are designed to be finger-tightened until they \"click\" into a locked state.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eBend Radius Constraints:\u003c\/strong\u003e Maintain a minimum bend radius of \u003cstrong\u003e25.4 mm (1 inch)\u003c\/strong\u003e. Sharp bends can damage the internal coaxial shielding and dielectric, leading to \"signal spiking\" or a \"Not OK\" status on the 3500 monitor.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eProper Cable Support:\u003c\/strong\u003e Use high-quality cable ties or clamps to secure the cable every 1 to 2 feet. Ensure that the cable is not under tension at the connector ends. Vibration-induced stress on unsupported cables is a leading cause of premature failure in proximity systems.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eSystem Matching:\u003c\/strong\u003e Always verify that the total length of the probe plus the extension cable matches the configuration of the Proximitor Sensor (e.g., a 7m Proximitor requires a total cable length of 7m). The \u003cstrong\u003e330930-065\u003c\/strong\u003e is part of a 7.0-meter system when used with a 0.5-meter probe.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516275563,"sku":"330930-065-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-00-05-3300-xl-nsv-extension-cable-ullgkoscfm2_2e5685e9-33f6-4078-b646-4488fbee5f5e.jpg?v=1765440087"},{"product_id":"bently-nevada-330930-065-03-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-03-05 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-065-03-05\u003c\/strong\u003e: 3300 NSv extension cable configuration specified by a 6.5-meter length (Option 065), unarmored cable construction with integrated connector protector (Option 03), and multiple hazardous area approvals (Option 05).\u003c\/p\u003e\n\u003cp\u003eThis 75-ohm coaxial \u003cstrong\u003e3300 NSv Extension Cable\u003c\/strong\u003e acts as the electrical link between a 3300 NSv proximity probe and a 3300 XL NSv Proximitor Sensor (Model 330980). It transmits high-frequency eddy-current signals to monitor radial shaft vibration, axial position, and speed in industrial rotating machinery with limited target geometry. The unarmored design provides maximum routing flexibility through protective conduit systems, while the pre-installed connector protector prevents fluids, turbine oils, and moisture from compromising the connection junction.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 065 specifies a 6.5-meter (21.3 feet) overall cable length.\u003c\/li\u003e\n  \u003cli\u003eOption 03 designates an unarmored coaxial construction that includes a factory-installed fluorosilicone connector protector on the female connector.\u003c\/li\u003e\n  \u003cli\u003eOption 05 offers multiple international certifications for intrinsically safe and non-incendive installation.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc miniature coaxial connectors ensure reliable high-frequency signal transmission and mechanical locking.\u003c\/li\u003e\n  \u003cli\u003eMinimum bend radius of 25.4 mm (1.0 inch) permits tight cable routing inside machinery casings and conduit networks.\u003c\/li\u003e\n  \u003cli\u003eCompatible with 3300 XL NSv proximity probes and Proximitor sensors to form a calibrated transducer system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAeroderivative gas turbines\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressors and high-speed turbomachinery with limited target area or tight clearance\u003c\/li\u003e\n  \u003cli\u003eRadial shaft vibration and axial position measurement in small-bore rotating machinery\u003c\/li\u003e\n  \u003cli\u003eEnclosed industrial gearboxes and high-speed pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330930-065-03-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable, 6.5 meters, unarmored, with connector protector, multiple approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length\u003c\/td\u003e\n      \u003ctd\u003e065\u003c\/td\u003e\n      \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector and Cable\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eWithout stainless steel armor, with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, and IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-065-03-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75-ohm coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (Unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded (fluorosilicone material on female connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.220 ohms\/meter (0.067 ohms\/foot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShield Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.066 ohms\/meter (0.020 ohms\/foot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExtension Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/meter (21.3 pF\/foot) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 inch)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System (330900 series probes and 330980 Proximitor Sensor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfirm that the combined length of the extension cable (6.5 m) and the matching probe equals the total calibrated length required by the Proximitor Sensor (typically 7.0 m system length).\u003c\/li\u003e\n  \u003cli\u003eEnsure ClickLoc connectors are only finger-tightened during installation. The maximum allowable connection torque is 0.56 N m (5 in lb). Do not use metallic tools or pliers.\u003c\/li\u003e\n  \u003cli\u003eMaintain a routing bend radius of no less than 25.4 mm (1.0 inch) to prevent damage to the inner coaxial conductor and shield.\u003c\/li\u003e\n  \u003cli\u003eVerify that the fluorosilicone connector protector is correctly seated over the probe-to-cable junction to shield the contacts from external turbine oil and moisture.\u003c\/li\u003e\n  \u003cli\u003eInstall the extension cable in accordance with the appropriate regional hazardous area control drawings (Bently Nevada drawing 141092 for intrinsically safe or drawing 140979 for non-incendive layouts).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American (cNRTLus):\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, and D (intrinsically safe when installed with approved barriers); Class I, Zone 2: AEx\/Ex nA\/ec IIC T4\/T5 Gc (non-incendive)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc; Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517946731,"sku":"330930-065-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-03-05-cable-extension-module-dj3putae3wr_e6f0dc8b-5aa7-4490-868d-050f8f816560.jpg?v=1765440113"},{"product_id":"bently-nevada-330930-045-01-00-3300-nsv-extension-cable","title":"Bently Nevada 330930-045-01-00 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330930-045-01-00\u003c\/strong\u003e is a \u003cstrong\u003e4.5-meter (14.8 feet) 3300 NSv Extension Cable\u003c\/strong\u003e engineered to provide precise signal path connectivity within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This unit is specifically configured for mid-range distance requirements where standard 4.0m or 5.0m cabling options create excessive or insufficient slack, necessitating a more exacting cable run in complex machinery cabinets.\u003c\/p\u003e\n\u003cp\u003eThis specific model utilizes a ruggedized architecture featuring \u003cstrong\u003eAISI 302 stainless steel armor\u003c\/strong\u003e without an FEP outer jacket. This construction balances physical durability—protecting the coaxial core against localized mechanical abrasions—with the necessary flexibility required for tight-radius routing inside compressor skids or turbine enclosures. It serves as a vital bridge in systems where the Proximitor Sensor is located in a protected, remote junction box away from the primary measurement point, ensuring that low-level eddy-current signals remain shielded from localized electromagnetic noise.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4.5m Length Precision:\u003c\/strong\u003e Provides an intermediate length option to optimize cable management and minimize signal attenuation in custom-configured monitoring loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless Steel Armor Protection:\u003c\/strong\u003e Includes flexible AISI 302 stainless steel armor, enhancing crush resistance and shielding against sharp installation edges without the additional bulk of an outer FEP jacket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Stability:\u003c\/strong\u003e Optimized to maintain linear signal response (voltage-to-gap) across the extended 4.5m span, critical for phase-sensitive applications like Keyphasor signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Mechanical Integrity:\u003c\/strong\u003e Equipped with field-proven, gold-plated brass ClickLoc connectors that provide a secure, vibration-proof latch, preventing signal intermittent behavior caused by connector fretting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Field Integration:\u003c\/strong\u003e Fully compliant with existing 3300 NSv hardware, allowing for easy integration into high-density probe arrays where routing space is at a premium.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Compressor Monitoring:\u003c\/strong\u003e Radial vibration and thrust position sensing on small-shaft turbomachinery where the sensor housing must be displaced by exactly 4.5 meters from the probe tip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced OEM Skids:\u003c\/strong\u003e Integration into pre-engineered compressor skids that demand specific, standardized cable lengths to ensure consistent signal timing across multiple machine trains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Routing in Dense Conduits:\u003c\/strong\u003e Deployment in cable-crowded environments where armored protection is essential for cable longevity, yet the absence of a bulky FEP jacket is preferred for improved pull-through performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer Array Synchronization:\u003c\/strong\u003e Managing phase reference signal paths in multi-probe tachometer systems requiring balanced cable lengths to avoid phase synchronization errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330930-045-01-00\u003c\/strong\u003e model identifier reflects the following technical configuration:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e045\u003c\/td\u003e\n\u003ctd\u003e4.5 meters (14.8 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Connector \u0026amp; Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eWith stainless steel armor, no FEP jacket, no connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot Required \/ Standard Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohms coaxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible AISI 302 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass (ClickLoc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 N (50 lb) max rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Core\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-grade coaxial with FEP insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Verification:\u003c\/strong\u003e Verify that the 3300 XL NSv Proximitor Sensor is configured for a 4.5m extension cable length (often part of a 5.0m or 7.0m total system calibration) to ensure measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmor Handling:\u003c\/strong\u003e When routing the stainless steel armored cable, ensure the armor ends are properly seated to prevent fraying and to maintain the electrical continuity of the shield path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Engagement:\u003c\/strong\u003e Use manual pressure to lock the ClickLoc connectors until a distinct click is felt. Do not apply thread-locking compounds to the connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Radius Maintenance:\u003c\/strong\u003e Maintain at least a 25.4 mm bend radius. Excessively tight bends may deform the coaxial core, causing local impedance mismatches that manifest as \"noise\" in the vibration data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e Designed to withstand industrial electromagnetic environments (EN 61000-6-2\/4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS\/China RoHS:\u003c\/strong\u003e Environmentally compliant with international hazardous substance directives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e Components are designed to support SIL-rated safety instrumented systems (SIS) when used with appropriate certified Proximitor modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519585131,"sku":"330930-045-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-045-01-00-3300-nsv-extension-cable-lepbil1xp11_512bcc11-8952-40ec-a08d-3f2fca984530.jpg?v=1765440136"},{"product_id":"bently-nevada-330730-040-02-00-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-040-02-00 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 040 (4.0 m cable length) and Option 02 (standard cable with connector protector) specify this 3300 XL 11 mm extension cable configuration — \u003cstrong\u003e330730-040-02-00\u003c\/strong\u003e. This unarmored coaxial cable links a 3300 XL 11 mm proximity probe with a 3300 XL 11 mm Proximitor sensor, completing a 5.0-meter or 9.0-meter transducer system. The standard FEP insulation offers excellent chemical resistance and temperature tolerance in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eUnlike armored variants or those featuring FluidLoc technology, this configuration focuses on flexibility and clean routing while adding a pre-installed fluorosilicone connector protector. The connector protector shields the ClickLoc junction against moisture and contaminants, which is ideal for humid or wet environments. Since Option 00 is selected for agency approvals, this specific variant does not require hazardous area compliance certificates.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 040 provides a 4.0-meter (13.1 feet) physical cable length.\u003c\/li\u003e\n  \u003cli\u003eOption 02 equips the cable with a pre-installed fluorosilicone connector protector on the female end.\u003c\/li\u003e\n  \u003cli\u003eOption 00 designates that no specific hazardous area agency approvals are required for this configuration.\u003c\/li\u003e\n  \u003cli\u003e75 Ohm triaxial construction with fluoroethylene propylene (FEP) insulation.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc coaxial connectors lock securely to prevent loosening from vibration.\u003c\/li\u003e\n  \u003cli\u003eUnarmored cable design maintains a minimum bend radius of 25.4 mm (1.0 in) for tight routing paths.\u003c\/li\u003e\n  \u003cli\u003eRated tensile strength of 270 N (60 pounds) at the probe lead to extension cable connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is used within Bently Nevada 3300 XL 11 mm proximity transducer systems for vibration and position monitoring of large rotating machinery. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial thrust position monitoring.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal and axial compressor vibration analysis.\u003c\/li\u003e\n  \u003cli\u003eCritical rotating machinery protection where 11 mm probe systems are required.\u003c\/li\u003e\n  \u003cli\u003eHumid or moist industrial environments where the connector protector prevents ingress of moisture into the coaxial junction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330730-040-02-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Extension Cable, standard unarmored coaxial cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required \/ No approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330730-040-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial, FEP-insulated coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClickLoc miniature coaxial connectors (gold-plated brass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePre-installed fluorosilicone connector protector on female end\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance (Core)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.3 +\/- 0.1 Ohm (center conductor to center conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance (Jacket)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 +\/- 0.25 Ohm (coaxial conductor to coaxial conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 lb) maximum at probe-to-cable connector interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHumidity Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTested to IEC 68-2-3 damp heat\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePairs with 3300 XL 11 mm probes and 330780 Proximitor Sensors\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the 3300 XL 11 mm extension cable, follow these engineering best practices to ensure optimal signal transmission and mechanical longevity:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 in) along the entire cable length to prevent internal conductor damage or impedance changes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection Integrity:\u003c\/strong\u003e Hand-tighten ClickLoc coaxial connectors. Do not use pliers or other tools that could over-torque and damage the gold-plated contacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Ensure the pre-installed fluorosilicone connector protector is fully seated and clicked over the junction to block moisture, dirt, and industrial oils.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRouting and Conduit:\u003c\/strong\u003e Route the cable through dedicated, grounded metal conduit to isolate the low-voltage signal from high-voltage electromagnetic interference (EMI) sources.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the system shield is properly grounded at the monitor\/instrumentation end only. Do not ground the cable shield at multiple points, as this can introduce ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330730-040-02-00 configuration is ordered with the Option 00 agency approval selection. As such, this specific extension cable is designed for use in non-hazardous, general-purpose industrial environments and does not carry individual explosion-proof or intrinsic safety certificates.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with European Community Directive 2011\/65\/EU (RoHS).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility (EMC):\u003c\/strong\u003e Complies with European Community Directive 2014\/30\/EU when used as part of a fully compatible and shielded Bently Nevada 3300 XL transducer system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525876587,"sku":"330730-040-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330730-040-02-00-extension-cable-cdoz0ldi1n2_0131774c-680c-4d2e-91b7-90f0083747a4.jpg?v=1765440272"},{"product_id":"bently-nevada-330190-085-00-05-3300-xl-extended-temperature-range-extension-cable","title":"Bently Nevada 330190-085-00-05 3300 XL Extended Temperature Range Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330190-085-00-05\u003c\/strong\u003e: 3300 XL Extended Temperature Range (ETR) extension cable, specifying an 8.5-meter length (Option 085) with standard unarmored construction (Option 00) and CSA, ATEX, and IECEx hazardous area approvals (Option 05). This component is designed for demanding proximity transducer installations where temperatures exceed the thresholds of standard cabling systems. The extension cable operates as a medium between the proximity probe and the Proximitor Sensor, conveying high-frequency eddy-current signals to measure shaft vibration, axial position, and speed on critical rotating machinery.\u003c\/p\u003e\n\n\u003cp\u003eIn contrast to armored ETR options such as Option 01, this variant (Option 00) features a standard unarmored PFA-insulated cable with a maximum outside diameter of 3.7 mm. Standard temperature extension cables (model 330130) are rated up to 177 Celsius (350 Fahrenheit), whereas this 330190 ETR cable provides an extended temperature rating of up to 260 Celsius (500 Fahrenheit). It uses gold-plated ClickLoc coaxial connectors on both ends to construct a secure and low-resistance signal path that remains stable under high vibrational stresses, matching the calibration performance of standard 3300 XL Proximitor Sensors without requiring manual recalibration.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 085 specifies an 8.5-meter (27.9 feet) overall cable length, designed to combine with compatible probes to complete a 9.0-meter proximity transducer system.\u003c\/li\u003e\n  \u003cli\u003eOption 00 provides a standard unarmored cable design featuring PFA insulation and a maximum outside diameter of 3.7 mm.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides CSA, ATEX, and IECEx certifications for use in hazardous areas.\u003c\/li\u003e\n  \u003cli\u003ePFA insulation material supports a continuous operating and storage temperature range of -51 Celsius to +260 Celsius (-60 Fahrenheit to +500 Fahrenheit).\u003c\/li\u003e\n  \u003cli\u003eGold-plated ClickLoc coaxial connectors require only finger-tight torque and feature an integrated locking mechanism to prevent loosening from vibration.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in CableLoc design provides a secure mechanical connection with high pull strength between the cable and connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and position monitoring in steam turbines, gas turbines, and generators.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection systems in hydrocarbon processing plants and petrochemical facilities.\u003c\/li\u003e\n  \u003cli\u003eHigh-temperature rotating machinery monitoring where ambient temperatures exceed 177 Celsius.\u003c\/li\u003e\n  \u003cli\u003eTurbo-compressor and gearbox diagnostic monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330190-085-00-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Extended Temperature Range (ETR) Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e085\u003c\/td\u003e\n      \u003ctd\u003e8.5 meters (27.9 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eStandard cable (unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330190-085-00-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtended Temperature Range (ETR) Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.5 meters (27.9 feet) (Option 085)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Armor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard unarmored cable (Option 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePFA (Perfluoroalkoxy) insulation and jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 Celsius to +260 Celsius (-60 Fahrenheit to +500 Fahrenheit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature male and female coaxial ClickLoc connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.7 mm (0.15 in) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) maximum pull strength (CableLoc design)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx (Option 05)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.29 kg (289 g)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e300 mm x 300 mm x 20 mm (H x W x D) (coiled)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFinger-tighten the gold \"click\" type connectors until they click to lock in place. No special tools are required.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the minimum cable bend radius of 25.4 mm (1.0 in) during installation to prevent damage to the internal coaxial conductors.\u003c\/li\u003e\n  \u003cli\u003eIf running through conduit, standard practice is to use connector protectors to safeguard against entry of dust and moisture.\u003c\/li\u003e\n  \u003cli\u003eEnsure the sum of the extension cable length and the probe length matches the calibrated length of the Proximitor Sensor (e.g., 9.0-meter total system length).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA: Intrinsically Safe and Non-Incendive approvals for hazardous locations.\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: Ex ia IIC T5...T1 Ga for intrinsically safe installations in Zone 0\/1\/2.\u003c\/li\u003e\n  \u003cli\u003eCE: Compliant with relevant European directives.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525909355,"sku":"330190-085-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330190-085-00-05-extension-cable-zep4dztnnhj_950e338e-0583-4a68-b80d-31b27002f02a.jpg?v=1765440273"},{"product_id":"bently-nevada-16710-21-interconnect-cable","title":"Bently Nevada 16710-21 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\n\u003cstrong\u003e16710-21\u003c\/strong\u003e: Bently Nevada 3-conductor shielded 22 AWG (0.5 mm2) armored interconnect cable, 21 ft (6.4 m) length, designed for use with 330400 and 330425 acceleration transducers. This cable assembly provides reliable signal transmission between the accelerometer and the monitoring system, featuring a 3-socket plug connector at the sensor end and terminal lugs at the signal termination end.\n\nThe armored construction provides mechanical protection for the cable in industrial environments, ensuring integrity against abrasion and external damage. As a standard Bently Nevada accessory, this cable is compatible with 330400\/330425 accelerometer installations where hazardous area approvals and robust signal cabling are required.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e3-conductor shielded 22 AWG (0.5 mm2) cable construction\u003c\/li\u003e\n\u003cli\u003eArmored exterior for mechanical durability and protection in industrial settings\u003c\/li\u003e\n\u003cli\u003e3-socket plug connector (mating connector) for 330400\/330425 accelerometers\u003c\/li\u003e\n\u003cli\u003eTerminal lug termination for secure connection to monitoring systems\u003c\/li\u003e\n\u003cli\u003eLength of 21 ft (6.4 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e330400 and 330425 Accelerometer systems\u003c\/li\u003e\n\u003cli\u003eCritical machinery protection and monitoring\u003c\/li\u003e\n\u003cli\u003eCasing vibration measurement\u003c\/li\u003e\n\u003cli\u003eGear mesh monitoring\u003c\/li\u003e\n\u003cli\u003eRotating machinery applications in power generation, petrochemical, and heavy industry\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption\u003c\/td\u003e\n\u003ctd\u003eCode on This SKU\u003c\/td\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e16710-21\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable, 21 ft length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e21 feet (6.4 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e16710-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded, armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Gauge\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e21 ft (6.4 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector (Sensor End)\u003c\/td\u003e\n\u003ctd\u003e3-socket plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination (System End)\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e330400 and 330425 Accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eEnsure the mating connector is fully seated to maintain IP rating integrity at the sensor connection.\u003c\/li\u003e\n\u003cli\u003eRoute cables through conduit or protected enclosures to prevent mechanical damage.\u003c\/li\u003e\n\u003cli\u003eObserve shielding requirements to minimize electromagnetic interference (EMI) in signal paths.\u003c\/li\u003e\n\u003cli\u003eWhen installing in hazardous areas, ensure the entire transducer system installation complies with the relevant area classification requirements and local electrical codes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526138731,"sku":"16710-21","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-21-interconnect-cable-lfwhkjwq5ls_84a0453d-b70e-469d-944d-fba55abd8677.jpg?v=1765440279"},{"product_id":"bently-nevada-330190-080-01-05-3300-xl-etr-extension-cable","title":"Bently Nevada 330190-080-01-05 3300 XL ETR Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 080 (8.0 m length) and Option 01 (integrated PFA-jacketed armor) define this specific 3300 XL ETR extension cable configuration — \u003cstrong\u003e330190-080-01-05\u003c\/strong\u003e. This cable is a component of the 3300 XL 8 mm Extended Temperature Range (ETR) proximity transducer system, which is used for non-contact shaft vibration and position measurements on rotating machinery. The 3300 XL ETR system is designed for severe industrial environments where temperatures exceed standard operating limits.\u003c\/p\u003e\n\n\u003cp\u003eThis armored cable configuration features a length of 8.0 meters (26.2 feet) and is constructed with a flexible stainless steel armor sheath over PFA insulation. The armoring guards the core coaxial line against crushing, pinching, and abrasive wear in harsh mounting paths. With Option 05 certifications, this cable complies with CSA, ATEX, and IECEx requirements for installation in hazardous area locations, making it suitable for chemical processing, oil refineries, and power generation machinery monitoring loops.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8.0 Meter Cable Length\u003c\/strong\u003e: Part segment 080 specifies an 8.0-meter physical length to complete the matching transducer loop requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Armoring\u003c\/strong\u003e: Segment 01 features stainless steel protective armor with a PFA outer jacket for robust physical defense.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Rating\u003c\/strong\u003e: PFA insulation is rated for extreme operating conditions between -52 and +260 Celsius.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location Approvals\u003c\/strong\u003e: Segment 05 provides North American and international ATEX, IECEx, and CSA safety certifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGold-Plated ClickLoc Connectors\u003c\/strong\u003e: Secure miniature male and female coaxial termination ends prevent signal loss without requiring specialized torque wrenches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical application environments for this cable configuration include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine bearing housing vibration and position monitoring loops.\u003c\/li\u003e\n\u003cli\u003eHigh-temperature refinery compressor shaft displacement systems.\u003c\/li\u003e\n\u003cli\u003eHot-end machinery and steam turbine casing monitoring.\u003c\/li\u003e\n\u003cli\u003eZone-rated industrial processing plants requiring explosion-proof instrumentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330190-080-01-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL ETR armored extension cable, 8.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Armor and Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eArmored cable (stainless steel armor with PFA jacket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, and IECEx approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification Parameter\u003c\/th\u003e\n\u003cth\u003eValue \/ Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330190-080-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtended Temperature Range (ETR) Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePFA (Perfluoroalkoxy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible stainless steel armor with PFA outer jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +260 Celsius (-62 to +500 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Armor Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.67 mm (0.302 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connectors (1 male, 1 female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.87 kg (1.92 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm x 280 mm x 45 mm (H x W x D) (coiled bundle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection End\u003c\/th\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eTarget Connection Point\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature female coaxial ClickLoc connector\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor connector sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish safe signal path integrity and avoid mechanical stress, please follow these guidelines:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius\u003c\/strong\u003e: Do not exceed the minimum cable bend radius of 50.8 mm (2.0 in) for the armored section of this extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Torque\u003c\/strong\u003e: Connect the miniature coaxial ends finger-tight only. Do not use pliers or torque keys as this may strip the gold-plated threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Areas\u003c\/strong\u003e: Install the cable runs in compliance with the barrier and wiring layout drawings specified by Bently Nevada approval guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Standard\u003c\/th\u003e\n\u003cth\u003eApproval Grade \/ Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Areas (Option 05)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC T5...T1 Ga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Sparking \/ Increased Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx nA IIC T5...T1 Gc \/ Ex ec IIC T5...T1 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDust Ignition Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia IIIC T90 Celsius ... T280 Celsius Dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526859627,"sku":"330190-080-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330190-080-01-05-extension-cable-l5xnio4gezn_8a3f64de-d10a-4ef4-bec8-3eb01badeee5.jpg?v=1765440290"},{"product_id":"bently-nevada-9571-32-standard-interconnect-cable","title":"Bently Nevada 9571-32 Standard Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e9571-32\u003c\/strong\u003e is a rugged, industrial-grade \u003cstrong\u003estandard interconnect cable\u003c\/strong\u003e designed for high-reliability signal transmission within machinery condition monitoring systems. Engineered to link machinery sensors or transmitters directly to asset protection monitors and processing racks, this cable ensures the uncompromised delivery of critical vibration, position, and speed raw waveforms. The model \u003cstrong\u003e9571-32\u003c\/strong\u003e utilizes a premium 22 AWG 2-conductor twisted, shielded pair architecture wrapped in a durable insulation layer to safeguard data integrity against aggressive electromagnetic interference (EMI) and radio frequency interference (RFI) common in plant environments.\u003c\/p\u003e\n\u003cp\u003eThe assembly features a factory-terminated, moisture-resistant 2-socket female connector block at one end to interface securely with field transducers, and standard bare wire terminal lugs at the opposing end for streamlined connection inside local monitor racks or termination blocks. The \u003cstrong\u003e-32\u003c\/strong\u003e suffix denotes a specific physical length of exactly 32 feet (approximately 9.7 meters). This cable is fully rated for continuous industrial operation across wide temperature variations, delivering stable signal dynamics for critical rotating assets without contributing data loss or capacitive distortion.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-integrity 2-conductor twisted, shielded pair configuration to block high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eFactory-installed 2-socket moisture-resistant female connector providing tight environment sealing at the transducer end.\u003c\/li\u003e\n\u003cli\u003ePre-installed terminal ring lugs at the monitor end for quick, reliable terminal strip mounting.\u003c\/li\u003e\n\u003cli\u003eRugged 22 AWG high-conductivity copper core layout maximizing signal path transmission efficiency.\u003c\/li\u003e\n\u003cli\u003eFlexible, orientation-agnostic construction allowing easy pathing through tightly packed wire tracks and conduits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnecting casing vibration velocity sensors or accelerometers to remote monitor frames.\u003c\/li\u003e\n\u003cli\u003eInterfacing field-mounted vibration transmitters directly with host control system analog cards.\u003c\/li\u003e\n\u003cli\u003eRouting dynamic diagnostic transducer lines through local junction cabinets to centralized monitoring panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571 (Standard Interconnect Cable Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-32 (Specified length of 32 feet \/ 9.75 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Twisted Shielded Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (Approximately 0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-conductor twisted pair with integrated drain wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull coverage aluminum-polyester shield line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-socket moisture-resistant molded female connector block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard pre-crimped terminal ring lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 300 V RMS operational insulation capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pull Tension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.2 lbs (17.8 kg) structural limit rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial performance envelope from -29 to 121 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStationary Minimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.28 in. (57.9 mm) mechanical limitation path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 ft. (9.75 m) fixed option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Compatibility Restriction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot for use inside 21128 Velocity Transducer Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNet weight approximately 0.8 kg (1.76 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable End Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePhysical Interface Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Transducer Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded 2-socket female connector with threaded locking mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Panel Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate positive, negative, and shield drain ring terminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Route Planning:\u003c\/strong\u003e Pull the cable assembly through dedicated low-voltage instrument conduits. Ensure it is path-isolated from high-current motor supply wires to minimize capacitive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer End Threading:\u003c\/strong\u003e Align the 2-socket female connector pins accurately with the sensor output pins. Tighten the connector sleeve to establish a compressed, moisture-resistant environmental seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Compliance:\u003c\/strong\u003e Maintain a physical path layout radius greater than 2.28 in. (57.9 mm) at all enclosure entry joints to prevent structural core strain or shielding separation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Drain Grounding:\u003c\/strong\u003e Terminate the instrument shield drain wire only at one designated common ground reference point (typically inside the monitor rack terminal block) to avoid generating problematic ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526957931,"sku":"9571-32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-32-cable-yfifvsfafj0_9f55ffc9-d680-4e6b-92ad-ee7e476cf3fd.jpg?v=1765440291"},{"product_id":"bently-nevada-330130-060-02-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-060-02-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nOption 060 (6.0 meters cable length) and Option 02 (standard cable with integrated fluorosilicone connector protector) specify this \u003cstrong\u003e3300 XL Standard Extension Cable\u003c\/strong\u003e configuration — \u003cstrong\u003e330130-060-02-05\u003c\/strong\u003e. This cable provides the physical and electrical transmission link between a 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor in non-contact displacement monitoring chains. In a complete transducer system, the total length of the probe and extension cable must match the required total system length of the Proximitor sensor (typically 5.0 or 9.0 meters).\n\nThe pre-installed connector protector (Option 02) provides environmental sealing for the gold-plated ClickLoc connector joint, preventing fluid, oil, dust, and moisture ingress in aggressive machinery environments. Option 05 designates the certificate package for explosive or hazardous atmospheres, supporting installation requirements across globally certified process environments.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 060 designates a 6.0 meters (19.7 feet) cable length, forming a matched 7.0 or 9.0 meters system when combined with the corresponding probe.\u003c\/li\u003e\n  \u003cli\u003eOption 02 includes standard cable pre-equipped with a fluorosilicone connector protector to seal and guard the connector joint against environmental contaminants.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides hazardous area approvals including CSA, ATEX, and IECEx certifications.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass and beryllium copper ClickLoc connectors provide positive locking with simple finger-tightening.\u003c\/li\u003e\n  \u003cli\u003eFluorinated Ethylene Propylene (FEP) cable insulation and outer jacket provide chemical, oil, and moisture resistance.\u003c\/li\u003e\n  \u003cli\u003eCable electrical resistance measures 1.32 ohms +\/- 0.21 ohms for the core conductor and 0.39 ohms +\/- 0.08 ohms for the outer jacket conductor over the 6.0 meters length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on high-speed rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eTurbine, generator, compressor, and pump protective monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eEnvironments requiring certified electrical apparatus for explosive or hazardous gas zones.\u003c\/li\u003e\n  \u003cli\u003eMachinery installations exposed to lubricating oils, hydraulic fluids, and severe moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Code\u003c\/th\u003e\n      \u003cth\u003eValue on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330130-060-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable, 6.0 m length, standard cable with connector protector, CSA\/ATEX\/IECEx approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length Option\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector Protector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-060-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard triaxial coaxial cable with FEP insulation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with connector protector (Option 02)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass and gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCore Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.32 ohms +\/- 0.21 ohms (typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Jacket Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.39 ohms +\/- 0.08 ohms (typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx (Option 05)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutside Diameter of Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.7 mm maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutside Diameter of Connector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12.4 mm maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e200 mm x 200 mm x 30 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector End\u003c\/th\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Connection End\u003c\/td\u003e\n      \u003ctd\u003eMiniature female coaxial ClickLoc\u003c\/td\u003e\n      \u003ctd\u003eConnects to the miniature male coaxial connector of the proximity probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Connection End\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc\u003c\/td\u003e\n      \u003ctd\u003eConnects to the female coaxial connector of the Proximitor sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the combined length of the proximity probe and the 6.0 m extension cable equals the calibrated system length specified on the Proximitor sensor label.\u003c\/li\u003e\n  \u003cli\u003eTighten the coaxial ClickLoc connectors finger-tight until they physically click; do not use mechanical tools.\u003c\/li\u003e\n  \u003cli\u003eSlide and fully seat the fluorosilicone connector protector sleeve over the mated connector joint to establish a moisture-proof seal.\u003c\/li\u003e\n  \u003cli\u003eObserve a minimum bend radius of 25.4 mm (1.0 inch) for the FEP coaxial cable during routing.\u003c\/li\u003e\n  \u003cli\u003eSecure the extension cable using non-conductive, oil-resistant cable ties or protective conduit to prevent physical wear and high-voltage interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA Certified: Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2; Class III\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: Zone 0, Zone 1, and Zone 2 explosive gas atmospheres\u003c\/li\u003e\n  \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527613291,"sku":"330130-060-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-060-02-05-extension-cable-0bunup5hoxy_c848148b-b374-40cf-9095-109af2168f0b.jpg?v=1765440300"},{"product_id":"bently-nevada-330730-040-01-05-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-040-01-05 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330730-040-01-05\u003c\/strong\u003e specifies this 3300 XL 11 mm extension cable configuration, featuring a 4.0 meter cable length, protective stainless steel armor, and a multiple agency approvals package. This cable is used within the 3300 XL 11 mm Proximity Transducer System, connecting the 3300 XL 11 mm proximity probe to the 3300 XL 11 mm Proximitor sensor for non-contact shaft vibration, axial position, and differential expansion monitoring.\u003c\/p\u003e\n\u003cp\u003eCompared to standard non-armored models like the 330730-040-00-05, this configuration incorporates flexible AISI 302 stainless steel armor with an outer FEP jacket to withstand mechanical abrasion, physical impact, and harsh industrial environments. While unarmored configurations are lighter and more flexible for clean environments, the armored jacket is essential in open industrial installations where cables are routed near sharp edges or high-traffic areas.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4.0 meter cable length (Option 040) designed to combine with a 1.0 meter probe to achieve a 5.0 meter total system length.\u003c\/li\u003e\n  \u003cli\u003eAISI 302 stainless steel armor (Option 01) with an outer FEP jacket for mechanical protection against abrasion and physical impacts.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass coaxial connectors providing secure, low-loss electrical contact.\u003c\/li\u003e\n  \u003cli\u003eMultiple agency approvals (Option 05) supporting cNRTLus, ATEX, and IECEx certifications for hazardous area installations.\u003c\/li\u003e\n  \u003cli\u003eTriaxial 75 ohm cable construction with fluoroethylene propylene (FEP) insulation.\u003c\/li\u003e\n  \u003cli\u003e25.4 mm (1.0 in) minimum bend radius allowing flexible routing in tight conduits and enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical application environments include rotating machinery protection in heavy industries such as oil and gas, power generation, petrochemicals, and water treatment:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial thrust position monitoring.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor rotor position and casing differential expansion measurements.\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor rod drop and rod position tracking.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator shaft runout and zero-speed monitoring.\u003c\/li\u003e\n  \u003cli\u003eBalance of plant rotating machinery protection in hazardous area environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from Manufacturer Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330730-040-01-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eArmored cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (cNRTLus, ATEX, and IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330730-040-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Length\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 SST with FEP outer jacket (armored cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Material\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCore dc Resistance\u003c\/td\u003e\n      \u003ctd\u003e0.3 +\/- 0.1 ohms (center conductor to center conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eJacket dc Resistance\u003c\/td\u003e\n      \u003ctd\u003e1.0 +\/- 0.25 ohms (coaxial conductor to coaxial conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Maximum Rated)\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 pounds) at probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Torque\u003c\/td\u003e\n      \u003ctd\u003eRecommended: finger tight; Maximum: 0.565 N-m (5 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnit Weight\u003c\/td\u003e\n      \u003ctd\u003e140 g\/m (1.5 oz\/ft) for armored cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating \u0026amp; Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMiniature female coaxial ClickLoc connector\u003c\/td\u003e\n      \u003ctd\u003eMates with 3300 XL 11 mm proximity probe coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n      \u003ctd\u003eMates with 3300 XL 11 mm Proximitor sensor coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eKeep the minimum bend radius of the armored cable to 25.4 mm (1.0 in) or greater during routing to prevent core damage.\u003c\/li\u003e\n  \u003cli\u003eHand-tighten coaxial connectors to ensure proper electrical mating; do not exceed the maximum torque limit of 0.565 N-m (5 in-lb).\u003c\/li\u003e\n  \u003cli\u003eProtect the connector junction using connector protectors or self-fusing silicone tape to prevent oil, moisture, and dust ingress.\u003c\/li\u003e\n  \u003cli\u003eDo not use silicone tape in environments where the cable connection will be directly exposed to turbine oil.\u003c\/li\u003e\n  \u003cli\u003eEnsure that the sum of the extension cable length and the probe length matches the total length rated on the Proximitor sensor (e.g., 4.0 m cable + 1.0 m probe equals a 5.0 m system).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEMC Directive 2014\/30\/EU, Standards EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU with China RoHS EFUP designation of 15 years\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: SIL 2 (HFT=0), SIL 3 (HFT=1) certified when used in a complete safety-instrumented system\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Approvals (Option 05):\n    \u003cul\u003e\n      \u003cli\u003ecNRTLus (Intrinsically Safe): Class I, Zone 0: AEx\/Ex ia IIC T5...T1 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n      \u003cli\u003ecNRTLus (Non-incendive): Class I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D\u003c\/li\u003e\n      \u003cli\u003eATEX\/IECEx: Ex ia IIC T5...T1 Ga (EPL Ga), Ex ia IIIC T90C...T280C Dc (EPL Dc), Ex nA\/ec IIC T5...T1 Gc (EPL Gc)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528399723,"sku":"330730-040-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330730-040-01-05-extension-cable-5ycpb2ud2io_f89520df-dbca-4e81-8b28-ab3a929576a8.jpg?v=1765440313"},{"product_id":"bently-nevada-330130-075-10-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-10-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 075 (7.5 meters cable length), Option 10 (FluidLoc cable), and Option 05 (CSA, ATEX, and IECEx approvals) specify this 3300 XL standard extension cable configuration — \u003cstrong\u003e330130-075-10-05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis configuration utilizes a 3.94 mm outside diameter FluidLoc triaxial cable to block process liquids and oils from migrating through the internal voids of the cable jacket. It connects a 3300 XL 8 mm proximity probe to a 3300 XL Proximitor sensor, establishing a total system length of 9.0 meters when matched with a 1.5-meter probe. The cable features gold-plated ClickLoc connectors that lock with finger-tight pressure to prevent connection degradation in environments with high mechanical vibration.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFluidLoc cable option to prevent migration of lube oil and other process fluids through the cable interior.\u003c\/li\u003e\n  \u003cli\u003eGold-plated ClickLoc coaxial connectors that secure with hand-tightening and resist vibrational loosening.\u003c\/li\u003e\n  \u003cli\u003e7.5 meters cable length matching standard 9.0-meter transducer system specifications.\u003c\/li\u003e\n  \u003cli\u003eNon-armored triaxial construction with FEP outer jacket offering high chemical resistance.\u003c\/li\u003e\n  \u003cli\u003eAgency approval option 05 certifying compliance with CSA, ATEX, and IECEx standards for hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eUsed in rotating machinery condition monitoring systems across heavy industrial processes including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine shaft vibration and axial position measurement\u003c\/li\u003e\n  \u003cli\u003eGas turbine casing and rotor displacement monitoring\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor radial vibration sensing\u003c\/li\u003e\n  \u003cli\u003eIndustrial gearbox shaft movement tracking\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator shaft vibration monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-075-10-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable, FluidLoc, hazardous area approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e075\u003c\/td\u003e\n      \u003ctd\u003e7.5 meters (24.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Connector Protector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc cable, no connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-075-10-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc triaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.5 meters (24.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutside Diameter (Jacket)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 mm (0.155 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaterial (Jacket)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFluorinated Ethylene Propylene (FEP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated coaxial ClickLoc connectors (one male, one female)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCore Resistance (R_CORE)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.65 ohms +\/- 0.25 ohms (center conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eJacket Resistance (R_JACKET)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.49 ohms +\/- 0.10 ohms (outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 degC (-62 to +350 Fahrenheit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e280 mm x 280 mm x 40 mm (H x W x D) (Coiled physical dimensions)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.26 kg (9.2 oz) (typical, excluding packaging)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eObserve the following installation criteria to ensure correct system performance:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDo not bend the cable tighter than the 25.4 mm minimum bend radius limits to prevent internal core damage.\u003c\/li\u003e\n  \u003cli\u003eTighten coaxial ClickLoc connectors by hand until they click; do not use pliers unless mating with older non-XL connectors.\u003c\/li\u003e\n  \u003cli\u003eEnsure field wiring and cable connections are shielded and isolated from sources of high electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eUse silicone tape or connector protectors if the connection is exposed to heavy external contaminants, although FluidLoc prevents internal migration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330130-075-10-05 cable is certified under the following standards when used with an approved proximity sensor and probe assembly:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA Class I, Division 1, Groups A, B, C, D\u003c\/li\u003e\n  \u003cli\u003eATEX Zone 0\/1 Ex ia IIC T4\/T5 Ga\/Gb\u003c\/li\u003e\n  \u003cli\u003eIECEx Ex ia IIC T4\/T5 Ga\/Gb\u003c\/li\u003e\n  \u003cli\u003eCE Mark compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529251691,"sku":"330130-075-10-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-075-10-05-extension-cable-k0kjwbqanxa_b0609b6e-6ba5-4ecc-8c2c-8a3a4cbb70a4.jpg?v=1765440327"},{"product_id":"bently-nevada-330930-040-01-00-3300-nsv-extension-cable","title":"Bently Nevada 330930-040-01-00 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-040-01-00\u003c\/strong\u003e is a 4.0-meter (13.1 feet) 3300 NSv Extension Cable specified with stainless steel armor and an outer FEP jacket (Option 01), without agency approvals (Option 00).\u003c\/p\u003e\n\u003cp\u003eThis cable interfaces between a 3300 NSv proximity probe and a 3300 XL NSv Proximitor Sensor. The addition of the FEP-jacketed stainless steel armor provides protection against physical wear, mechanical shear, and chemical exposure in demanding industrial environments, distinguishing it from standard unarmored configurations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4.0 meters (13.1 feet) overall cable length configuration (Option 040).\u003c\/li\u003e\n  \u003cli\u003eStainless steel protective armor with protective FEP jacket (Option 01).\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc miniature coaxial connectors provide a secure, twist-locking connection.\u003c\/li\u003e\n  \u003cli\u003eDesigned to match 3300 NSv probe impedance and signal characteristics.\u003c\/li\u003e\n  \u003cli\u003eFEP outer jacket resists oils, chemical solvents, and high humidity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and position monitoring in narrow or restricted spaces.\u003c\/li\u003e\n  \u003cli\u003eSmall-bore turbomachinery and aeroderivative gas turbine installations.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed centrifugal compressors and pumps with limited target geometries.\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery where mechanical armor protection against hot oils and abrasion is necessary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330930-040-01-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable, 4.0 meters, armored with FEP jacket, no approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length Option\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eWith stainless steel armor, with FEP jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-040-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStainless steel armor with outer FEP (Fluorinated Ethylene Propylene) jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature coaxial connectors (male\/female)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected (tested to IEC 68-2-3 damp heat)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.220 ohm\/m (0.067 ohm\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShield Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.066 ohm\/m (0.020 ohm\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTypical Cable Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 g\/m (0.7 oz\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Pull Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) connector-to-cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation of the 3300 NSv extension cable ensures stable signal transmission and mechanical durability. Follow these engineering guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 inch) during routing to prevent internal conductor damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e While this configuration does not include pre-installed connector protectors, it is recommended to use connector protectors or silicone self-fusing tape in wet or oil-exposed environments to prevent signal degradation. Do not use silicone tape inside the machine casing if exposed to turbine oil.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRouting:\u003c\/strong\u003e Route cables away from high-voltage lines, AC motors, and other electromagnetic interference sources. Secure cables with appropriate mounting clips without over-tightening.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque:\u003c\/strong\u003e Connect the probe-to-cable miniature ClickLoc connectors to finger tight, then apply a maximum recommended torque of 0.56 Nm (5 in-lb) using proper tools. Do not use pliers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal Length Verification:\u003c\/strong\u003e Ensure that the combined length of the proximity probe and the extension cable matches the total calibrated length of the 3300 XL NSv Proximitor Sensor (typically 5.0 m or 7.0 m).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529808747,"sku":"330930-040-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-040-01-00-3300-nsv-extension-cable-lugo243go3o_42f9bef1-03c2-4945-aa8b-f0e90a75f752.jpg?v=1765440341"},{"product_id":"bently-nevada-330930-060-03-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-060-03-05 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-060-03-05\u003c\/strong\u003e specifies this 3300 NSv extension cable configuration, featuring a 6.0-meter length, no stainless steel armor, an integrated connector protector, and multiple hazardous area approvals. This industrial coaxial cable provides the critical connection between a 3300 NSv proximity probe and a 3300 XL NSv Proximitor sensor. It is engineered to transmit high-frequency eddy-current signals with minimal attenuation, maintaining calibrated system impedance for high-accuracy non-contact displacement measurements.\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL NSv transducer system is intended for rotating machinery with narrow target areas or restricted installation clearances, such as aeroderivative gas turbines, high-speed compressors, and small-bore pump shafts. This specific unarmored extension cable integrates a durable fluorosilicone connector protector that isolates the miniature ClickLoc coaxial connection from moisture, grease, and industrial cutting fluids, preventing impedance changes or signal dropouts.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise 6.0-Meter Length:\u003c\/strong\u003e Option 060 provides a 6.0-meter (19.7 feet) physical length to span distance between the machine casing and local junction boxes without excess slack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnarmored Design with Connector Protector:\u003c\/strong\u003e Option 03 designates a flexible, lightweight coaxial cable without rigid metal armoring, combined with a pre-installed protective sleeve to seal the connection points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultiple Hazardous Area Approvals:\u003c\/strong\u003e Option 05 qualifies the cable assembly for global safety certifications, including ATEX, IECEx, and CSA ratings for explosive or hazardous environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eImpedance-Matched 75-Ohm Design:\u003c\/strong\u003e Standardizes transmission characteristics to eliminate signal reflection and support high-fidelity vibration and axial position measurements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Coaxial Connectors:\u003c\/strong\u003e Corrosion-resistant, gold-plated brass connectors establish a positive lock that withstands persistent machine vibrations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position monitoring on high-speed aeroderivative gas turbines.\u003c\/li\u003e\n  \u003cli\u003eRadial dynamic motion measurements on small-bore machinery with narrow shaft targets.\u003c\/li\u003e\n  \u003cli\u003eVibration monitoring on centrifugal compressors and high-speed turbopumps.\u003c\/li\u003e\n  \u003cli\u003eRestricted-clearance machinery installations where rigid stainless steel armor is not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-060-03-05\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable (6.0 meters, unarmored with connector protector, multiple approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eWithout stainless steel armor, with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple approvals (CSA, ATEX, IECEx, etc.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-060-03-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75-ohm coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (Unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature ClickLoc coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded (fluorosilicone material)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.220 ohm\/m (0.067 ohm\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShield Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.066 ohm\/m (0.020 ohm\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe-lead-to-extension-cable connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 g\/m (0.5 oz\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Length Match:\u003c\/strong\u003e Ensure that the combined physical length of the proximity probe and this extension cable matches the exact system length of the Proximitor sensor (typically 5.0 meters or 7.0 meters).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Cleanliness:\u003c\/strong\u003e Keep the miniature coaxial connectors clean and free of oil, water, and contaminants prior to mating. Moisture or debris inside the connector will degrade system calibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Torque:\u003c\/strong\u003e ClickLoc coaxial connectors must be joined finger-tight. The maximum rated torque limit is 0.56 Nm (5 in-lb) to prevent damage to the gold-plated contacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRouting and Bend Limits:\u003c\/strong\u003e Route the cable through protective conduit or cable trays where possible. Maintain a minimum bend radius of 25.4 mm (1.0 in) during installation to prevent internal conductor breakage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Ensure the option 03 connector protector is fully seated over the connection point to isolate the mated junction from surrounding environmental spray.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T5...T1 Ga\u003cbr\u003eEx ia IIIC T90C...T280C Dc (for EPL Dc)\u003cbr\u003eEx nA IIC T5...T1 Gc\u003cbr\u003eEx ec IIC T5...T1 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCSA \/ NRTL \/ C\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClass I, Zone 0\/2: AEx\/Ex ia IIC \/ nA IIC \/ ec IIC T5...T1 Ga\/Gc\u003cbr\u003eClass I, Division 1 \u0026amp; 2, Groups A, B, C, D\u003cbr\u003eClass II, Groups E, F, G\u003cbr\u003eClass III\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSIL 2 Certified (HFT = 0)\u003cbr\u003eSIL 3 Certified (HFT = 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Directives\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eStandards: EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEuropean Directive 2011\/65\/EU Compliant\u003cbr\u003eChina RoHS: 15-year EFUP designation\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666531610987,"sku":"330930-060-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-060-03-05-3300-nsv-extension-cable-whkdcm1qppx_7230ffde-b390-4693-b00c-771483dd8653.jpg?v=1765440363"},{"product_id":"bently-nevada-330130-085-13-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-085-13-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-085-13-05\u003c\/strong\u003e: 3300 XL standard extension cable, 8.5 meters in length (Option 085), utilizing armored FluidLoc construction with a connector protector (Option 13), and certified for CSA, ATEX, and IECEx hazardous area environments (Option 05). This extension cable facilitates communication between the 3300 XL probe and the Proximitor sensor, maintaining signal integrity in critical machinery monitoring applications.\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc cable design prevents liquid migration through the cable jacket, protecting the internal conductors from oil or other process fluids. The inclusion of armor provides mechanical protection against abrasion in demanding industrial environments, while the connector protector guards the miniature coaxial ClickLoc connector interface from environmental ingress. This specific configuration is rated for global hazardous area installations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8.5 meter total cable length for 3300 XL transducer system integration\u003c\/li\u003e\n\u003cli\u003eArmored cable construction for superior mechanical and abrasion resistance\u003c\/li\u003e\n\u003cli\u003eFluidLoc cable design to mitigate liquid ingress through the cable jacket\u003c\/li\u003e\n\u003cli\u003eConnector protector included for added protection of the ClickLoc interface\u003c\/li\u003e\n\u003cli\u003eCSA, ATEX, and IECEx hazardous area approval rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine shaft vibration monitoring\u003c\/li\u003e\n\u003cli\u003eCompressor axial position measurement\u003c\/li\u003e\n\u003cli\u003eCritical rotating machinery protection\u003c\/li\u003e\n\u003cli\u003eFluid-sealed or oil-exposed installation environments\u003c\/li\u003e\n\u003cli\u003eGlobal industrial facilities requiring hazardous area certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330130-085-13-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length\u003c\/td\u003e\n\u003ctd\u003e085\u003c\/td\u003e\n\u003ctd\u003e8.5 meters (27.9 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Cable Option\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330130-085-13-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc with Connector Protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the total system length (probe plus extension cable) matches the requirements of the Proximitor sensor calibration. Route cables through protective conduit to minimize EMI\/RFI interference and mechanical strain. Use standard wrench torque values for connecting ClickLoc connectors; ensure the connector protector is fully seated. Verify that the cable armor is properly grounded at the terminal or junction box to maintain shielding effectiveness.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA (Canadian Standards Association)\u003c\/li\u003e\n\u003cli\u003eATEX (Atmospheres Explosibles)\u003c\/li\u003e\n\u003cli\u003eIECEx (International Electrotechnical Commission Explosive Atmospheres)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666531676523,"sku":"330130-085-13-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-085-13-05-standard-extension-cable-443un4bmur2_fe0f4ea5-4405-474b-ba46-56f50fd3c34b.jpg?v=1765440364"},{"product_id":"bently-nevada-84661-66-330750-series-interconnection-cables","title":"Bently Nevada 84661-66 330750 Series Interconnection Cables","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e84661-66\u003c\/strong\u003e specifies a 66-foot (20.1 m) standard armored \u003cstrong\u003einterconnection cable\u003c\/strong\u003e used with the Bently Nevada 330750 High Temperature Velomitor System (HTVS) to link the sensor conditioning electronics to the machinery monitor. This cable construction consists of stainless steel armor over a shielded 0.382 mm2 (22 AWG) twisted pair cable, providing high mechanical protection in harsh industrial environments. It is fitted with a moisture-resistant female connector at the HTVS transducer end and terminated with ring lugs at the monitor or receiver end.\u003c\/p\u003e\n\n\u003cp\u003eUnlike the unarmored 9571-NN standard interconnect cable, the 84661-66 variant integrates a flexible stainless steel conduit armor to protect the inner conductors against mechanical abrasion, crushing forces, and environmental degradation. This 66-foot cable configuration allows operators to position sensitive condition-monitoring electronics up to 20.1 meters away from high-temperature machinery surfaces, maintaining stable vibration signals without thermal degradation of the transmitter.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e66-foot (20.1 m) overall cable length provides flexible routing from high-temperature machinery locations to cool electronics or termination enclosures.\u003c\/li\u003e\n  \u003cli\u003eStainless steel armor wrapping protects the 22 AWG inner conductors against severe abrasion, impact, and mechanical routing hazards.\u003c\/li\u003e\n  \u003cli\u003eShielded 0.382 mm2 (22 AWG) twisted pair copper conductors maintain signal integrity and reduce electromagnetic and radio frequency interference.\u003c\/li\u003e\n  \u003cli\u003eMoisture-resistant female connector pre-installed at the HTVS transducer end ensures a sealed connection.\u003c\/li\u003e\n  \u003cli\u003ePre-terminated ring lugs at the monitor end facilitate secure screw-terminal connection inside monitoring panels.\u003c\/li\u003e\n  \u003cli\u003eOperating temperature range of -29 degC to 121 degC (-20 degF to 250 degF) covers most industrial routing paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on industrial machinery using the 330750 High Temperature Velomitor System.\u003c\/li\u003e\n  \u003cli\u003eHigh-temperature processing environments including steam turbines, gas turbines, and industrial piping where physical protection of cabling is required.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical, power generation, and steel manufacturing plants with high mechanical abuse risks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e84661\u003c\/td\u003e\n      \u003ctd\u003eStandard Armored Interconnect Cable (with stainless steel armor, shielded 22 AWG cable, moisture-resistant female connector at HTVS end, ring lugs at monitor end)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOption NN (Length)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e66\u003c\/td\u003e\n      \u003ctd\u003e66 feet (approximately 20.1 meters) overall cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e84661-66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard Armored Interconnect Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eShielded twisted pair\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStainless steel armor sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector (Transducer End)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMoisture-resistant 2-pin female connector (compatible with HTVS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTermination (Monitor End)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRing lugs (\"A\" White, \"B\" Black, \"SHLD\" Green)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-29 degC to 121 degC (-20 degF to 250 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e66 ft (approx. 20.1 m) +\/- 6.0 in (152.4 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Interconnect Run\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 m (1000 ft) max for High Temperature Velomitor System (HTVS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eWire \/ Terminal\u003c\/th\u003e\n      \u003cth\u003eFunction \/ Color\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin A\u003c\/td\u003e\n      \u003ctd\u003eWhite (Signal +)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin B\u003c\/td\u003e\n      \u003ctd\u003eBlack (Signal - \/ Return)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSHLD\u003c\/td\u003e\n      \u003ctd\u003eGreen (Shield Ground)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUse shielded cabling to minimize electrostatic and electromagnetic noise.\u003c\/li\u003e\n  \u003cli\u003eEnsure the stainless steel armored jacket is securely tied down along the run using cable clamps.\u003c\/li\u003e\n  \u003cli\u003eAvoid routing in areas where the ambient temperature exceeds 121 degC (250 degF) to preserve cable insulation.\u003c\/li\u003e\n  \u003cli\u003eTerminate the green shield wire to the appropriate monitor ground or instrument ground. Do not ground both ends of the shield to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003eAvoid tight bends or pinching of the stainless steel armor to prevent inner conductor damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Fully compatible with Bently Nevada 330750 High Temperature Velomitor System (HTVS) which supports ATEX\/IECEx (Ex ia IIC or IIB, Ex ec IIC or IIB) and CSA\/UL certifications when installed in accordance with system guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666531709291,"sku":"84661-66","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-84661-66-velomitor-interconnect-cable-ujczhwzxg3n_0446cfb7-f752-4485-ad5d-78a8ab91d293.jpg?v=1765440365"},{"product_id":"bently-nevada-9571-17-interconnect-cable","title":"Bently Nevada 9571-17 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eThe Bently Nevada 9571-17 is a heavy-duty, standard interconnect cable assembly optimized for industrial machinery condition monitoring and vibration tracking loops. Engineered with a \u003cstrong\u003e2-conductor twisted, shielded pair\u003c\/strong\u003e configuration utilizing high-grade 22 AWG conductors, this rugged assembly serves as the key signal link between transducers—such as the Velomitor piezo-velocity sensors or specialized low-frequency accelerometers—and proximity or vibration monitors. It features an integrated 2-socket moisture-resistant female connector at the sensor-facing terminus and prepared terminal ring lugs at the backend interface for clean cabinet termination. Designed to handle severe industrial conditions, this instrumentation cable provides optimal shielding attenuation to reject electromagnetic interference (EMI) and radio frequency interference (RFI) across extended field runs. The option code 17 specifies a precise fixed length of 17 feet (5.2 meters) to maintain consistent impedance control within customized system layouts without extra coil accumulation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTwisted-Pair Shielded Construction:\u003c\/strong\u003e 22 AWG double-conductor design minimizes inductive crosstalk and cross-talk noise across long industrial signal runs.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMoisture-Resistant Connection:\u003c\/strong\u003e Outfitted with an overmolded 2-socket female connector on the field terminus to prevent liquid ingress in humid environments.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePre-Terminated Monitor Lugs:\u003c\/strong\u003e Features durable terminal ring lugs at the cabinet side for direct connection onto terminal strips without field crimping.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Thermal Envelope:\u003c\/strong\u003e Rated to withstand continuous operational temperature exposures ranging from -29 degC to +121 degC.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eOptimized System Length:\u003c\/strong\u003e Pre-cut 17-foot option prevents excess loop storage while satisfying point-to-point field bridging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eInterconnecting Velomitor piezo-velocity sensors with remote diagnostic monitors or continuous monitoring racks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eMachinery monitoring systems in oil and gas extraction facilities, petrochemical refining complexes, and municipal pumping stations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eCritical absolute casing vibration loops on high-speed rotating equipment, large cooling fans, and industrial pumps.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eField routing within protective conduit tracks where severe EMI interference requires high-integrity drain shields.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eModel Code\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eConfiguration Option\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eTechnical Value Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e9571\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBase Assembly Model\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStandard Interconnect Cable (2-Conductor, 22 AWG, Shielded)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e-17\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCable Length Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e17 feet (5.2 meters) continuous length\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConductor Gauge\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e22 AWG (0.382 mm2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCore Arrangement\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2-conductor twisted pair with integrated drain wire\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eField Connection End\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2-socket moisture-resistant female molded connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMonitor Connection End\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePre-installed ring terminal lugs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-29 degC to +121 degC (-20 degF to +250 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaximum Allowed System Loop\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e305 meters (1000 feet) maximum total run when matched with approved sensor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eApplication Constraints\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNot for use inside the 21128 Velocity Transducer Housing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eU.S.A.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 Kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e280 mm x 280 mm x 25 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and fully de-energize the machine monitoring system loop prior to pulling, routing, or terminating instrumentation wiring. Handling live field signals near high-energy machinery sections can induce dangerous system loop faults, trigger accidental process shutdowns, or create electrical discharge hazards.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eField engineers must strictly observe the following professional connection sequence:\u003c\/p\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eRoute the cable through dedicated, grounded steel conduit lines to isolate the 22 AWG twisted pairs from high-voltage motor power feeds.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInspect the 2-socket moisture-resistant female head for any contaminants, debris, or moisture prior to mating with the sensor housing connector receptacle.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eEngage the female thread assembly tightly onto the sensor receptacle to create a fully sealed environmental barrier against liquid ingress.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eLand the backend ring terminal lugs securely on the terminal blocks inside the panel enclosure, anchoring the shield wire to the designated instrumentation ground point.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666534232427,"sku":"9571-17","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-17-interconnect-cable-l321dmvfk5l_98ba226c-f49e-40a1-bad8-c775e9af6fc1.jpg?v=1765440398"},{"product_id":"bently-nevada-330130-075-01-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-075-01-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330130-075-01-05\u003c\/strong\u003e is a 7.5-meter armored extension cable designed for use within the \u003cstrong\u003e3300 XL 8 mm Proximity Transducer System\u003c\/strong\u003e. This configuration, identified by option codes 075 (7.5 m length), 01 (armored cable), and 05 (agency approvals), facilitates the connection between a 3300 XL probe and a 3300 XL Proximitor sensor, maintaining signal integrity in critical machinery monitoring applications.\u003c\/p\u003e\n\n\u003cp\u003eThe cable utilizes Bently Nevada's ClickLoc connectors, which ensure a secure, gold-plated connection for consistent signal transmission. The inclusion of the armored sheath (Option 01) provides additional mechanical protection for the cable lead in demanding industrial environments. This unit is compatible with 3300 XL 8 mm probe systems used for shaft vibration, axial position, and rotor speed measurements on rotating equipment like turbines, compressors, and pumps.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e7.5 meter total cable length (Option 075)\u003c\/li\u003e\n    \u003cli\u003eArmored cable construction (Option 01) for enhanced durability in harsh environments\u003c\/li\u003e\n    \u003cli\u003eCertified for hazardous area use with CSA, ATEX, and IECEx approvals (Option 05)\u003c\/li\u003e\n    \u003cli\u003eEquipped with gold-plated ClickLoc connectors for reliable signal path and quick installation\u003c\/li\u003e\n    \u003cli\u003eDesigned specifically for integration with 3300 XL 8 mm probe and Proximitor sensor chains\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eCritical machinery protection for turbines, compressors, and gearboxes\u003c\/li\u003e\n    \u003cli\u003eShaft radial vibration measurement\u003c\/li\u003e\n    \u003cli\u003eAxial thrust position monitoring\u003c\/li\u003e\n    \u003cli\u003eRotor speed and phase reference measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003cth\u003eOption\u003c\/th\u003e\n        \u003cth\u003eCode on This SKU\u003c\/th\u003e\n        \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n        \u003ctd\u003e330130-075-01-05\u003c\/td\u003e\n        \u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eA - Cable Length\u003c\/td\u003e\n        \u003ctd\u003e075\u003c\/td\u003e\n        \u003ctd\u003e7.5 meters (24.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eB - Cable Option\u003c\/td\u003e\n        \u003ctd\u003e01\u003c\/td\u003e\n        \u003ctd\u003eArmored cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n        \u003ctd\u003e05\u003c\/td\u003e\n        \u003ctd\u003eCSA, ATEX, IECEx approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eManufacturer\u003c\/td\u003e\n        \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003ePart Number\u003c\/td\u003e\n        \u003ctd\u003e330130-075-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eCable Type\u003c\/td\u003e\n        \u003ctd\u003eArmored extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eCable Length\u003c\/td\u003e\n        \u003ctd\u003e7.5 meters (24.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eConnector Type\u003c\/td\u003e\n        \u003ctd\u003eGold-plated ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n        \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eWeight\u003c\/td\u003e\n        \u003ctd\u003e103 g\/m (typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the extension cable length, when combined with the probe length, matches the calibration requirements of the Proximitor sensor (typically 5 or 9 meters total). Use finger-tight torque for ClickLoc connectors. For outdoor or high-moisture environments, Bently Nevada recommends using connector protectors or silicone self-fusing tape to prevent environmental degradation of the connections. Route cables through conduit or cable trays to prevent damage to the armored sheath.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis SKU includes Option 05, certifying it for use in hazardous areas under CSA, ATEX, and IECEx standards. Verify site-specific requirements against the Approvals Quick Reference Guide (108M1756) for the most current compliance documentation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666535018859,"sku":"330130-075-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-075-01-05-extension-cable-rcy2emvnzsu_71e7f3f3-8034-40ff-91d2-b9d9336f5c6d.jpg?v=1765440405"},{"product_id":"bently-nevada-16925-30-interconnect-cables","title":"Bently Nevada 16925-30 Interconnect Cables","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e16925-30\u003c\/strong\u003e is a 30 ft (9.0 m) \u003cstrong\u003einterconnect cable\u003c\/strong\u003e designed for use with Bently Nevada 330400 and 330425 acceleration transducers. This 3-conductor shielded 22 AWG (0.5 mm2) cable provides the necessary electrical path for casing vibration signals between the accelerometer and the monitoring system.\u003c\/p\u003e\n\n\u003cp\u003eThis cable configuration features a 3-socket plug on the transducer end and terminal lugs on the monitoring system end, allowing for secure and reliable connection in machinery protection applications. The 30 ft length makes this assembly suitable for installations where the monitoring equipment is located at a distance from the machine casing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLength: 30 ft (9.0 m)\u003c\/li\u003e\n\u003cli\u003eCable Type: 3-conductor shielded 22 AWG (0.5 mm2)\u003c\/li\u003e\n\u003cli\u003eConnection A: 3-socket plug (transducer end)\u003c\/li\u003e\n\u003cli\u003eConnection B: Terminal lugs (instrumentation end)\u003c\/li\u003e\n\u003cli\u003eApplication: Designed for 330400 and 330425 series accelerometers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCritical machinery protection systems\u003c\/li\u003e\n\u003cli\u003eGear mesh monitoring\u003c\/li\u003e\n\u003cli\u003eCasing acceleration measurements\u003c\/li\u003e\n\u003cli\u003eRotor vibration transmission monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e16925-30\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption A - Cable Length\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e30 ft (9.0 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e16925-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e30 ft (9.0 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e3-conductor, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Connector\u003c\/td\u003e\n\u003ctd\u003e3-socket plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Connector\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003e330400, 330425 Accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the 3-socket plug is properly seated on the accelerometer connector to maintain system integrity. The cable should be routed through conduit or protected enclosures to prevent mechanical damage or environmental interference. Standard installation practices for industrial cabling apply; ensure shielding is properly terminated at the monitor end to minimize noise interference in the signal path.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666536657259,"sku":"16925-30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16925-30-interconnect-cable-xxld1cytxyp_b390db3b-cfd3-4107-b576-819c30074ec5.jpg?v=1765440423"},{"product_id":"bently-nevada-330854-40-24-00-3300-xl-25-mm-extension-cable","title":"Bently Nevada 330854-40-24-00 3300 XL 25 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330854-40-24-00\u003c\/strong\u003e: 3300 XL 25 mm \u003cstrong\u003eextension cable\u003c\/strong\u003e, featuring Option 40 for a 4.0-meter cable length, Option 24 for an unarmored high-temperature FluidLoc cable, and Option 00 representing the standard safe-area configuration without agency approvals. This specialized triaxial cable is designed to bridge Bently Nevada 330851 proximity probes and 330850 Proximitor sensors in large-target eddy-current measurement configurations, supporting differential expansion and shaft movement monitoring.\u003c\/p\u003e\n\u003cp\u003eUnlike armored system variants (such as Option 25) which include a stainless steel outer armor sleeve, the Option 24 version utilizes a raw FluidLoc coaxial outer PFA jacket. This construction minimizes bulk and optimizes routing flexibility in protected conduit installations while maintaining moisture-resistant front and rear seals. The integrated high-temperature ClickLoc coaxial connectors ensure reliable low-resistance connections in harsh rotating machinery environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable Length: 4.0 meters (13.1 feet) total length (Option 40).\u003c\/li\u003e\n\u003cli\u003eCable Type: Standard unarmored FluidLoc coaxial cable (Option 24) with a moisture-resistant perfluoroalkoxyethylene (PFA) jacket.\u003c\/li\u003e\n\u003cli\u003eHazardous Area Approvals: Standard uncertified design (Option 00) for standard industrial applications.\u003c\/li\u003e\n\u003cli\u003eLow-Resistance Connectors: Gold-plated brass and gold-plated beryllium copper miniature ClickLoc connectors.\u003c\/li\u003e\n\u003cli\u003eRugged Construction: Designed to withstand continuous high temperature exposures up to +200 degC (+392 degF).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 25 mm transducer system is typically used in heavy-duty machinery for large-target displacement monitoring, particularly in steam turbine differential expansion and shaft position monitoring. Common installations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine thrust position monitoring\u003c\/li\u003e\n\u003cli\u003eDifferential expansion and axial position measurement\u003c\/li\u003e\n\u003cli\u003eRod-drop monitoring in reciprocating compressors\u003c\/li\u003e\n\u003cli\u003eLarge-diameter shaft vibration analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330854-40-24-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Armor and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003eHigh Temperature FluidLoc cable, unarmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330854-40-24-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer System Series\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable Type\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, PFA insulated FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Jacket\u003c\/td\u003e\n\u003ctd\u003eNone (unarmored PFA outer jacket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Materials\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass and gold-plated beryllium copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Resistance (Core to Core, RCORE)\u003c\/td\u003e\n\u003ctd\u003e1.0 +\/- 0.25 ohms (for 4.0 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Resistance (Jacket to Jacket, RJACKET)\u003c\/td\u003e\n\u003ctd\u003e0.3 +\/- 0.1 ohms (for 4.0 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature male and female coaxial ClickLoc connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +200 degC (-31 degF to +392 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Limit\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Tensile Strength\u003c\/td\u003e\n\u003ctd\u003e270 N (60 pounds) at probe lead to extension cable connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Calibration Target\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e330851 proximity probes and 330850 Proximitor sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure proper performance and physical protection of the 3300 XL 25 mm extension cable, follow these engineering practices:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain the recommended minimum bend radius of 25.4 mm (1.0 in) along the entire cable path to prevent coaxial signal degradation or mechanical stress.\u003c\/li\u003e\n\u003cli\u003eConnectors should be kept dry and free from contaminants. Always install the provided connector protectors before routing or exposing the connections to industrial fluids.\u003c\/li\u003e\n\u003cli\u003eTighten the coaxial ClickLoc connectors finger tight. Do not exceed the maximum rated connector-to-connector torque of 0.565 N-m (5 in-lb) to avoid damage to the gold-plated conductors.\u003c\/li\u003e\n\u003cli\u003eRoute the unarmored cable within dedicated metallic conduits or protective trays to guard against environmental impact, abrasive contact, or crushing hazards inside the machine enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe standard system configuration complies with the European CE mark for electromagnetic compatibility (EMC). As an Option 00 configuration, this component is designed without hazardous area approvals and is intended for use in safe industrial zones.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666537443691,"sku":"330854-40-24-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330854-40-24-00-3300-xl-25-mm-extension-cable-qga45dniowp_60e6ae8b-806c-4ad5-96bc-7f064d9e3900.jpg?v=1765440429"},{"product_id":"bently-nevada-330130-080-13-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-080-13-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 080 (8.0 m cable length) and Option 13 (armored FluidLoc cable with connector protector) specify this 3300 XL extension cable configuration - \u003cstrong\u003e330130-080-13-05\u003c\/strong\u003e. This \u003cstrong\u003e3300 XL standard extension cable\u003c\/strong\u003e connects a 3300 XL 8 mm proximity probe to a 3300 XL Proximitor sensor, facilitating eddy-current displacement measurements in industrial environments. The integrated FluidLoc technology prevents oil and other lubricants from leaking through the cable interior, making it suitable for pressurized or fluid-filled machine casings.\u003c\/p\u003e\n\u003cp\u003eCompared to unarmored standard cable variants, this model features heavy-duty stainless steel armor with an outer jacket, offering mechanical protection against abrasion, crushing, and physical impacts. The built-in fluorosilicone connector protectors provide environmental sealing at the connections, safeguarding against moisture and contaminant ingress. This configuration also features Option 05 hazardous area approval, certifying it for use in intrinsically safe environments with ATEX, IECEx, and CSA standards.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 080 provides an exact 8.0-meter cable length, forming a calibrated 9-meter system when paired with a 1.0-meter proximity probe.\u003c\/li\u003e\n\u003cli\u003eOption 13 specifies armored FluidLoc construction, preventing inner-cable fluid migration while offering heavy-duty physical armor.\u003c\/li\u003e\n\u003cli\u003eIntegrated fluorosilicone connector protectors seal the gold-plated ClickLoc connectors against fluids and contamination.\u003c\/li\u003e\n\u003cli\u003eOption 05 approval package certifies the transducer system for intrinsically safe and non-incendive environments.\u003c\/li\u003e\n\u003cli\u003ePatented CableLoc design provides 330 N tensile strength to prevent cable separation at the joints.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eUsed primarily in industrial machinery protection and condition monitoring setups, such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine shaft vibration and axial position measurement.\u003c\/li\u003e\n\u003cli\u003eCompressor and pump casing penetration points where oil containment is vital.\u003c\/li\u003e\n\u003cli\u003ePetrochemical and power generation environments requiring ATEX, IECEx, or CSA hazardous area zone ratings.\u003c\/li\u003e\n\u003cli\u003eAggressive mechanical environments requiring robust armored shielding against physical wear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Selected Option\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330130-080-13-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable, Armored FluidLoc with Connector Protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet) length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Connector Protector \u0026amp; Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals (Intrinsically Safe \/ Non-Incendive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330130-080-13-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc triaxial FEP insulated cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible AISI 302 or 304 stainless steel with FEP outer jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutside Cable Diameter (FluidLoc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.94 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.67 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Ferrule Max Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Protector Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.4 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated miniature coaxial ClickLoc connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFinger tight (audible click)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore DC Resistance (R_CORE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.76 +\/- 0.26 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket DC Resistance (R_JACKET)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 +\/- 0.11 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 N at cable-to-connector joints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mm x 250 mm x 50 mm (H x W x D) (Coiled shipping profile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish a proper installation for the 3300 XL Standard Extension Cable, observe the following engineering guidelines:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the combined length of the extension cable and proximity probe matches the total calibrated length of the Proximitor sensor (e.g., an 8.0 m extension cable requires a 1.0 m probe for a 9.0 m system).\u003c\/li\u003e\n\u003cli\u003eObserve the minimum bend radius limit of 25.4 mm to prevent inner-core conductor fatigue or signal degradation.\u003c\/li\u003e\n\u003cli\u003ePrior to mating, inspect the gold-plated coaxial ClickLoc connectors for cleanliness. Tighten the connectors only by hand until they audibly \"click\" into position.\u003c\/li\u003e\n\u003cli\u003eSlide the fluorosilicone connector protectors fully over the junction to ensure complete environmental sealing against water, process chemicals, and particulate matter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals (Option 05)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Intrinsically Safe (Ex ia) and Non-Incendive (Ex nA\/ec) certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx Certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC T5...T1 Ga, Ex ia IIIC T90C...T280C Dc, Ex ec IIC T5...T1 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with European Community Directive 2014\/30\/EU (EN 61000-6-2, EN 61000-6-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Directive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with European Community Directive 2011\/65\/EU and China RoHS (15-year EFUP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 2 (HFT = 0), SIL 3 (HFT = 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666538099051,"sku":"330130-080-13-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-080-13-05-extension-cable-dy300r4i41d_42021568-935f-4ede-8220-b79e9b04c098.jpg?v=1765440436"},{"product_id":"bently-nevada-89477-80-right-angle-interconnect-cable","title":"Bently Nevada 89477-80 Right Angle Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 89477-80\u003c\/strong\u003e is a ruggedized shielded interconnect cable assembly designed to link machinery instrumentation with centralized machinery monitoring systems. This specialized data loop component measures 80 feet (24.0 meters) in total length and is constructed from robust 0.963 mm2 (18 AWG) conductors to ensure stable instrumentation link characteristics. To allow clean signal paths in tight structural envelopes while providing a secure fit in unconditioned, damp operational spaces, the transducer connection side features a factory-integrated, moisture-resistant right-angle female plug, complemented by standardized industrial ring lugs on the monitor termination interface. The multi-conductor infrastructure features a heavy shielding barrier to minimize external ground-loop disruptions and high-frequency noise emissions, protecting vital vibration and condition data trends across demanding industrial thermal ranges.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAssembled with robust internal 0.963 mm2 (18 AWG) shielded instrumentation cables.\u003c\/li\u003e\n\u003cli\u003ePre-terminated with a specialized moisture-resistant right-angle female plug on the transducer path end.\u003c\/li\u003e\n\u003cli\u003eIntegrated heavy-duty ring lugs on the monitoring system panel interface.\u003c\/li\u003e\n\u003cli\u003eEngineered with premium shielding paths to block local unconditioned noise emissions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-integrity instrumentation signal paths connecting field machinery sensors to core asset condition monitors.\u003c\/li\u003e\n\u003cli\u003eDense space terminal routings or unconditioned process zones demanding right-angle moisture-sealed links.\u003c\/li\u003e\n\u003cli\u003eContinuous vibration loop tracks on critical industrial rotating machinery exposed to wide climate spans.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe model code structure for this right-angle interconnect cable assembly follows a standardized length selection system. The part number prefix is paired with a specific two-digit suffix that indicates the total length of the cable in feet.\u003c\/p\u003e\n\u003cp\u003eUse the configuration table below to identify or specify the exact orderable model number based on your system length requirements:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrderable Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCable Length (Feet)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCable Length (Meters)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ft\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 ft\u003c\/td\u003e\n\u003ctd\u003e3.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 ft\u003c\/td\u003e\n\u003ctd\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-17\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 ft\u003c\/td\u003e\n\u003ctd\u003e5.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ft\u003c\/td\u003e\n\u003ctd\u003e6.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ft\u003c\/td\u003e\n\u003ctd\u003e7.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ft\u003c\/td\u003e\n\u003ctd\u003e9.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-33\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003ctd\u003e10.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ft\u003c\/td\u003e\n\u003ctd\u003e15.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-80\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 ft\u003c\/td\u003e\n\u003ctd\u003e24.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-99\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 ft\u003c\/td\u003e\n\u003ctd\u003e30.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight Angle Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 ft (24.0 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.963 mm2 (18 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Design Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Connection Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant right angle female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Connection Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 degC (-20 to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Position\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Interface Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer End\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant right angle female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLay out the 80-foot instrumentation loop along designated industrial cable conduits, preventing severe sharp mechanical bends or excessive pulling friction.\u003c\/li\u003e\n\u003cli\u003eThread and fully seat the moisture-resistant right-angle female connector onto the transducer head housing terminal to complete the environmental seal.\u003c\/li\u003e\n\u003cli\u003eAnchor the heavy-duty ring lugs securely to the terminal rail blocks inside the monitoring system chassis, establishing firm mechanical retention.\u003c\/li\u003e\n\u003cli\u003eSeparate the sensor communication path from high-voltage primary motor power leads to prevent field noise coupling or transient signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666538983787,"sku":"89477-80","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-89477-80-interconnect-cable-4h2fzgxxi5b_bca57e98-6d9a-4633-a2be-aa944da286d1.jpg?v=1765440447"},{"product_id":"bently-nevada-330930-040-01-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-040-01-05 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-040-01-05\u003c\/strong\u003e: \u003cstrong\u003e3300 NSv extension cable\u003c\/strong\u003e configured with a 4.0-meter cable length (Option 040), stainless steel armor with an FEP jacket (Option 01), and multiple agency approvals (Option 05). This cable connects a 3300 NSv proximity probe to a 3300 XL NSv Proximitor Sensor, completing the eddy-current measurement chain. It is used in situations with tight clearances and restricted target areas where standard proximity systems are physically too large.\u003c\/p\u003e\n\n\u003cp\u003eThis variant includes physical armor and FEP jacketing, which protects the internal coaxial line from physical abrasion, crushing, and exposure to corrosive chemicals or process fluids. The combination of a 4.0 m extension cable and a 1.0 m probe (or similar matching configurations) forms a standard 5.0 m system length. The integrated ClickLoc miniature coaxial connectors provide a secure, low-loss electrical connection that resists moisture ingress when properly sealed.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 040 specifies a 4.0-meter (13.1-foot) physical cable length.\u003c\/li\u003e\n\u003cli\u003eOption 01 integrates stainless steel armor with a protective FEP jacket for harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003eOption 05 includes multiple international agency approvals for installation in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eClickLoc miniature coaxial connectors establish secure connections without requiring specialized torque tools.\u003c\/li\u003e\n\u003cli\u003eExtremely low electrical loss with 75-ohm characteristic impedance matching the 3300 XL NSv sensor system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 330930-040-01-05 extension cable is used in machinery protection systems for rotating equipment with limited target geometries. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAeroderivative gas turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal and axial compressors with compact housings\u003c\/li\u003e\n\u003cli\u003eSmall-bore machinery and high-speed pumps\u003c\/li\u003e\n\u003cli\u003eFluid-film bearing radial vibration and axial position measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930-040-01-05\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e040\u003c\/td\u003e\n\u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eWith stainless steel armor, with FEP jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx, NEPSI, and others)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330930-040-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Impedance\u003c\/td\u003e\n\u003ctd\u003e75 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable DC Resistance\u003c\/td\u003e\n\u003ctd\u003eCenter conductor: 0.220 ohms\/m (0.067 ohms\/ft); Shield: 0.066 ohms\/m (0.020 ohms\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Outer Protection\u003c\/td\u003e\n\u003ctd\u003eStainless steel armor with FEP jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connectors (one male, one female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Pull Strength\u003c\/td\u003e\n\u003ctd\u003e220 N (50 lb) cable-to-connector maximum tensile load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the 330930-040-01-05 extension cable, ensure the total physical length of the probe plus the extension cable matches the calibration length of the 3300 XL NSv Proximitor Sensor (typically 5.0 meters or 7.0 meters). Maintain a minimum bend radius of 25.4 mm (1.0 inch) to prevent physical or electrical degradation of the coaxial core. Protect the coaxial ClickLoc connectors from moisture, dirt, and process lubricants by using silicone self-fusing tape or dedicated connector protectors. Avoid routing extension cables adjacent to high-voltage conduits or high-power AC cables to minimize electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis transducer component is approved under the 3300 XL NSv system for use in hazardous areas when ordered with Option 05 approvals. Verified certifications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T5...T1 Ga, Ex ia IIIC T90 degC...T280 degC Dc, Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus:\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with European Community Directive 2011\/65\/EU and China RoHS (EFUP designation of 15 years)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility (EMC):\u003c\/strong\u003e EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (HFT = 0), SIL 3 certified (HFT = 1)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666547601771,"sku":"330930-040-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-040-01-05-3300-nsv-extension-cable-a4zqpt4vllh_6fe2f5ba-b0f2-4fdd-bc28-14da81fb3313.jpg?v=1765440534"},{"product_id":"bently-nevada-330930-65-05-00-3300-nsv-extension-cable","title":"Bently Nevada 330930-65-05-00 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330930-65-05-00\u003c\/strong\u003e is a 3300 NSv extension cable configured for industrial displacement monitoring where physical clearances are limited and small shaft target geometries are present. This cable has an active length of 6.5 meters (21.3 feet) and is constructed with protective stainless steel armor without an outer FEP jacket, featuring a pre-installed connector protector at the probe-to-cable joint. It acts as the signal transmission link within a 7.0-meter 3300 XL NSv proximity transducer system, connecting a 0.5-meter 3300 NSv proximity probe to a 3300 XL NSv Proximitor Sensor.\u003c\/p\u003e\n\u003cp\u003eThe rugged armored construction on this variant provides mechanical guarding against abrasion, pinching, and impact forces in tight machinery casing environments, while omitting the outer polymer FEP jacket to reduce the cable outer diameter and comply with specific chemical or weight constraints. The integrated connector protector prevents liquids, lubricating oils, and moisture from contaminating the gold-plated coaxial ClickLoc joint, maintaining clean signal transmission over long operating cycles. This specific configuration is supplied under Option 00 (approvals not required) and is designed for general-purpose, non-hazardous industrial areas.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e6.5-meter length option establishes a complete 7.0-meter transducer measurement chain when mated with a 0.5-meter proximity probe.\u003c\/li\u003e\n  \u003cli\u003eFlexible stainless steel armor provides heavy physical protection against mechanical wear without the added bulk of an FEP jacket.\u003c\/li\u003e\n  \u003cli\u003eIntegrated connector protector shields the delicate coaxial junction against process lubricants, moisture, and debris.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc coaxial connectors secure connections with a positive locking mechanism to prevent loosening from machine vibration.\u003c\/li\u003e\n  \u003cli\u003eProprietary CableLoc design provides robust pull strength to prevent accidental separation of the probe-to-cable connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is used in critical rotating machinery applications requiring compact eddy-current displacement measurements:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCentrifugal and axial industrial compressors with limited internal mounting space.\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines and high-speed turbomachinery with small target areas.\u003c\/li\u003e\n  \u003cli\u003eSmall-bore pump shafts and tight-clearance radial vibration measurement paths.\u003c\/li\u003e\n  \u003cli\u003eGeneral-purpose industrial machinery installations where hazardous area approvals are not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe 330930-65-05-00 part number represents the following configuration options defined by Bently Nevada:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Identifier\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e65\u003c\/td\u003e\n      \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eWith stainless steel armor, without FEP jacket, with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eAgency approval not required (general purpose)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-65-05-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Family Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStainless steel armor (without FEP jacket)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded (installed on female end)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable DC Resistance (Center Conductor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.220 ohms\/meter (0.067 ohms\/foot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable DC Resistance (Shield)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.066 ohms\/meter (0.020 ohms\/foot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/meter (21.3 pF\/foot) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 inch)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExtension Cable Mass (Armored)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 g\/meter (0.7 oz\/foot) typical (approximately 416 g total cable mass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector-to-Connector Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFinger tight recommended; maximum torque 0.56 Nm (5 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper field installation ensures low signal-to-noise ratios and consistent transducer measurements:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAlways verify that the sum of the probe length and extension cable length matches the calibration length of the Proximitor Sensor (7.0 meters in this configuration).\u003c\/li\u003e\n  \u003cli\u003eObserve the minimum bend radius of 25.4 mm (1.0 inch) when routing the armored cable through conduit or machinery casings to prevent coaxial core damage.\u003c\/li\u003e\n  \u003cli\u003eEnsure the connector protector is fully seated over the probe-to-cable ClickLoc junction to prevent chemical or lubricant ingress.\u003c\/li\u003e\n  \u003cli\u003eUse silicone self-fusing tape (such as Bently Nevada part 03200006) for extra protection if the connector protector is exposed to extreme environments (note that tape is not recommended inside machinery casings exposed directly to hot turbine oil).\u003c\/li\u003e\n  \u003cli\u003eSecure the armored cable at regular intervals using appropriate clips or mounting blocks to prevent whip or mechanical wear during high-vibration operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666548027755,"sku":"330930-65-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-65-05-003300-nsv-extension-cable-ibbe1bxeunr_0677e8a7-993d-4b4d-a96e-b41383476a68.jpg?v=1765440545"},{"product_id":"bently-nevada-330130-060-00-00-3300-xl-8-mm-standard-extension-cable","title":"Bently Nevada 330130-060-00-00 3300 XL 8 mm Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e330130-060-00-00\u003c\/strong\u003e is a 6.0 meter (19.7 feet) 3300 XL standard extension cable designed for use in 3300 XL 8 mm proximity transducer systems. This configuration (Option 060 cable length, Option 00 standard cable, Option 00 no agency approval) provides a reliable, high-integrity connection between the 3300 XL proximity probe and the Proximitor sensor.\n\nThis extension cable features standard coaxial construction, compatible with the 3300 XL series' ClickLoc connectors. It is engineered to maintain system accuracy and interchangeability when paired with Bently Nevada proximity probes and Proximitor sensors, ensuring precise measurement of shaft vibration and axial position in rotating machinery such as turbines, compressors, and pumps.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6.0 meter (19.7 feet) total extension cable length\u003c\/li\u003e\n\u003cli\u003eStandard cable configuration (Option 00)\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 XL 8 mm probes and Proximitor sensors\u003c\/li\u003e\n\u003cli\u003eMiniature ClickLoc coaxial connectors for consistent and reliable signal transmission\u003c\/li\u003e\n\u003cli\u003eDesigned for critical rotating machinery monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine and compressor shaft vibration monitoring\u003c\/li\u003e\n\u003cli\u003eRotor axial position measurement\u003c\/li\u003e\n\u003cli\u003eRotating machinery protection on 8 mm proximity probe systems\u003c\/li\u003e\n\u003cli\u003eIndustrial power generation and petrochemical facility assets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption\u003c\/td\u003e\n\u003ctd\u003eCode on This SKU\u003c\/td\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330130-060-00-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length\u003c\/td\u003e\n\u003ctd\u003e060\u003c\/td\u003e\n\u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Connector\/Cable\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330130-060-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature ClickLoc coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the total combined length of the probe and extension cable matches the calibrated length for the Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003eRoute cables in protective conduit or cable trays to prevent physical damage or interference.\u003c\/li\u003e\n\u003cli\u003eUse the ClickLoc connector mechanism to ensure a secure, fully seated connection; do not over-tighten.\u003c\/li\u003e\n\u003cli\u003eMaintain proper separation from high-voltage cabling to prevent signal noise or electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify the cable is not bent beyond its minimum bend radius during installation to prevent damage to the coaxial core.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666557038955,"sku":"330130-060-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-060-00-00-extension-cable-bpluhhehf0u_04319e4b-236e-4333-ae91-1940ac3edb02.jpg?v=1765440632"},{"product_id":"bently-nevada-330930-045-05-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-045-05-05 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330930-045-05-05\u003c\/strong\u003e is a \u003cstrong\u003e3300 NSv extension cable\u003c\/strong\u003e designed for use within the Bently Nevada 3300 XL NSv proximity transducer system. This specific configuration is defined by a 4.5-meter (14.8 feet) total cable length, protective stainless steel armor without an outer FEP jacket, an integrated fluorosilicone connector protector, and multiple international hazardous area approvals. It is engineered for industrial environments where space is highly restricted, and machinery shafts or targets are exceptionally small, requiring robust mechanical protection without adding unnecessary diameter or weight.\u003c\/p\u003e\n\u003cp\u003eUnlike standard non-armored cables or variants equipped with heavy FEP jacketing, this configuration uses uncoated stainless steel armor to defend the internal coaxial media against physical cutting, pinch points, and abrasive wear. The integrated connector protector provides a reliable environmental seal over the ClickLoc miniature coaxial interface, preventing moisture, turbine oil, and other industrial contaminants from degrading the electrical signal. This extension cable connects a 3300 NSv proximity probe directly to a 330980 Proximitor sensor, establishing a complete calibrated signal path for dynamic vibration and position monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable Length Option: 4.5 meters (14.8 feet) provides precise physical reach for standard 5.0-meter or 7.0-meter system length layouts.\u003c\/li\u003e\n\u003cli\u003eUncoated Armor Protection: Stainless steel armor provides high mechanical protection without the added bulk or thermal limitations of an outer plastic sheath.\u003c\/li\u003e\n\u003cli\u003eSealed ClickLoc Junction: Features an integrated fluorosilicone connector protector that isolates the male-to-female connector mating face from fluid intrusion.\u003c\/li\u003e\n\u003cli\u003eClickLoc Connectors: Gold-plated brass miniature coaxial connectors secure the connection with minimal signal impedance.\u003c\/li\u003e\n\u003cli\u003eAgency Approvals: Option 05 offers multiple hazardous area certifications, including ATEX, IECEx, and CSA, for deployment in intrinsically safe or non-sparking zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is used in machinery diagnostics and protection systems across various demanding industrial installations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed centrifugal compressors and turbochargers with limited casing access.\u003c\/li\u003e\n\u003cli\u003eAeroderivative gas turbines and industrial steam turbines.\u003c\/li\u003e\n\u003cli\u003eFluid-film bearing machinery where small-shaft geometries restrict the use of larger standard probes.\u003c\/li\u003e\n\u003cli\u003eVibration and thrust position monitoring in hazardous chemical and hydrocarbon processing facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Selected Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930-045-05-05\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Extension Cable, 75 ohm coaxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e045\u003c\/td\u003e\n\u003ctd\u003e4.5 meters (14.8 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eWith stainless steel armor, without FEP jacket, with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (including ATEX, IECEx, CSA, NEPSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e330930-045-05-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Impedance\u003c\/td\u003e\n\u003ctd\u003e75 ohms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Resistance\u003c\/td\u003e\n\u003ctd\u003eCenter conductor: 0.220 ohm\/m (0.067 ohm\/ft)\u003cbr\u003eShield: 0.066 ohm\/m (0.020 ohm\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Construction\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass ClickLoc miniature coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Specifications\u003c\/td\u003e\n\u003ctd\u003eUncoated stainless steel armor (no outer FEP jacket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Protector Material\u003c\/td\u003e\n\u003ctd\u003eFluorosilicone elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Strength\u003c\/td\u003e\n\u003ctd\u003e220 N (50 lb) maximum rated connector-to-cable pull strength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Torque\u003c\/td\u003e\n\u003ctd\u003eFinger tight recommended; 0.56 N m (5 in lb) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sealing\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish safe and reliable performance, please follow these industrial installation practices:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that the sum of the probe length and the extension cable length exactly matches the calibrated total length of the Proximitor sensor (typically 5.0 meters or 7.0 meters).\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum bend radius of 25.4 mm (1.0 in) along all sections of the armored cable to avoid damaging the internal coaxial core.\u003c\/li\u003e\n\u003cli\u003eSlide the fluorosilicone connector protector firmly over the ClickLoc coaxial connection to seal the interface and shield it from moisture or machine oil.\u003c\/li\u003e\n\u003cli\u003eKeep the cable isolated from high-voltage conduit routing to prevent electromagnetic noise from interfering with the low-voltage vibration signal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eUnder Option 05, this component carries several international certifications for safe operation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx:\u003c\/strong\u003e Certified for intrinsically safe (Ex ia IIC Ga\/Dc) and non-sparking\/ec (Ex nA\/ec IIC Gc) hazardous environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American (CSA\/cNRTLus):\u003c\/strong\u003e Approved for Class I, Zone 0\/2, Groups A, B, C, D and Class II, Groups E, F, G.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 (HFT=0) and SIL 3 (HFT=1) certified when integrated within an approved safety-instrumented loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Meets European Community Directive 2011\/65\/EU and Chinese environmental safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666561397099,"sku":"330930-045-05-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-045-05-05-3300-nsv-extension-cable-ajubuuz3a3w_ce54ed4a-ced2-4789-934b-2dcd370b0b37.jpg?v=1765440656"},{"product_id":"bently-nevada-16925-66-interconnect-cables","title":"Bently Nevada 16925-66 Interconnect Cables","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e16925-66\u003c\/strong\u003e is a 3-conductor shielded interconnect cable designed for use with Bently Nevada acceleration transducer systems. This specific configuration features a 66-foot (20.1 meter) total length, providing the necessary reach for complex machinery installations where the signal must be routed from the transducer to a junction box or monitoring instrument. The cable is constructed with 22 AWG (0.5 mm2) conductors and is terminated with a 3-socket plug at the transducer end and terminal lugs at the instrumentation end, ensuring a secure and reliable connection.\u003c\/p\u003e\n\n\u003cp\u003eInterconnect cables in this series are essential for maintaining signal integrity in critical machinery protection applications. The shielded design minimizes electromagnetic interference, while the robust 3-socket connector ensures compatibility with standard 3300 series accelerometer receptacles. This 66-foot variant allows for flexible routing in large-scale industrial environments, such as power generation facilities or petrochemical processing plants, where longer cable runs are required to connect casing-mounted accelerometers to the protection system.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e66-foot (20.1 m) total cable length\u003c\/li\u003e\n\u003cli\u003e3-conductor shielded 22 AWG (0.5 mm2) construction for robust signal transmission\u003c\/li\u003e\n\u003cli\u003e3-socket plug connector at the sensor interface\u003c\/li\u003e\n\u003cli\u003eTerminal lugs at the termination end for secure wiring to terminal blocks\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 series accelerometer systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCritical machinery casing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eGear mesh monitoring in rotating equipment\u003c\/li\u003e\n\u003cli\u003eLong-distance cable runs in industrial enclosures\u003c\/li\u003e\n\u003cli\u003eHarsh industrial environments requiring shielded signal protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e16925-66\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable, 66 ft (20.1 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003ctd\u003e66 feet (20.1 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e3-socket plug\u003c\/td\u003e\n\u003ctd\u003eStandard 3-pin configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003ctd\u003eInstrumentation end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e16925-66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e66 ft (20.1 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector (Sensor End)\u003c\/td\u003e\n\u003ctd\u003e3-socket plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector (Instrument End)\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to +121 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that cables are routed through protective conduit where possible to prevent mechanical damage and exposure to harsh chemicals. Maintain proper separation from high-voltage AC power lines to avoid induced noise on the signal leads. When connecting to the 3-socket plug, ensure the connector is fully seated to maintain environmental integrity. Secure the terminal lugs at the instrument end according to the specified torque requirements of the terminal block, ensuring that the shield is properly grounded as per the site instrumentation standards.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666561528171,"sku":"16925-66","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16925-66-interconnect-cable-hteady31q4x_7c0507a2-7ba5-40e6-b345-4cca304b1e6f.jpg?v=1765440661"},{"product_id":"bently-nevada-330930-065-00-00-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-00-00 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330930-065-00-00\u003c\/strong\u003e serves as a precision-calibrated \u003cstrong\u003e6.5-meter (21.3 feet) extension cable\u003c\/strong\u003e within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This specific configuration is tailored for specialized applications requiring longer signal runs, typically utilized in monitoring setups where the Proximitor Sensor housing is located at a significant distance from the probe measurement point—such as in deep-frame reciprocating machinery or distributed compressor stations.\u003c\/p\u003e\n\u003cp\u003eUnlike variants equipped with added mechanical armor or auxiliary fluid shields, the \u003cstrong\u003e00-00\u003c\/strong\u003e configuration utilizes a streamlined, low-profile design. This reduces the overall diameter and weight of the cable harness, facilitating efficient installation through confined cable trays and congested machine housing ports. It maintains the system’s signature electrical stability and noise immunity, ensuring that the critical gap-to-voltage signals remain accurate even over the extended 6.5-meter distance. It features standard gold-plated \u003cstrong\u003eClickLoc\u003c\/strong\u003e connectors for a reliable, vibration-resistant electrical interface.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended 6.5-Meter Reach:\u003c\/strong\u003e Designed to support unique installation layouts where a standard 5.0m or 7.0m system length requires custom signal routing or peripheral mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStreamlined \"00\" Build:\u003c\/strong\u003e A lightweight, unarmored configuration that prioritizes ease of cable management and maneuverability in tight, high-density industrial settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Interface Connectivity:\u003c\/strong\u003e Utilizes factory-tested, gold-plated brass ClickLoc connectors to ensure high signal conductivity and long-term resistance to fretting corrosion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity Focus:\u003c\/strong\u003e Optimized for low-capacitance signal transmission, preventing phase shift or attenuation often associated with longer cable runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Interoperability:\u003c\/strong\u003e Fully compatible with existing 3300 XL NSv sensors, maintaining linear output characteristics across the entire rated gap range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Monitoring:\u003c\/strong\u003e Ideal for machines where the terminal housing must be mounted away from the primary measurement zone to avoid high-temperature or high-vibration hotspots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReciprocating \u0026amp; Gas Compressor Trains:\u003c\/strong\u003e Monitoring thrust and radial vibration on systems requiring longer cabling runs to reach centralized control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy System Modernization:\u003c\/strong\u003e Providing a precise 6.5m length solution for upgrading older proximity monitoring setups that utilize specific, non-standard cable run lengths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyphasor Signal Extension:\u003c\/strong\u003e Routing reference signals from remote tachometer probes to the proximity monitor, ensuring high-frequency signal clarity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe part number \u003cstrong\u003e330930-065-00-00\u003c\/strong\u003e is decoded as follows:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e065\u003c\/td\u003e\n\u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Connector \u0026amp; Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard (No armor, No connector protector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot Required \/ Standard Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 m (21.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClickLoc (Gold-plated brass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohm nominal impedance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny (Non-directional signal transmission)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Verification:\u003c\/strong\u003e Because this cable utilizes a non-standard length (6.5m), verify that the Proximitor Sensor is correctly calibrated for the total system length (Probe + Extension Cable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStress-Free Routing:\u003c\/strong\u003e Without the protection of stainless steel armor, avoid routing this cable over sharp edges or in areas susceptible to falling debris, high-pressure steam, or abrasive chemical exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Seating:\u003c\/strong\u003e During installation, ensure the ClickLoc mechanism is fully engaged. Since this specific part number (00-00) lacks the external connector boot, verify the environment is clean and dry to prevent terminal oxidation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Slack Management:\u003c\/strong\u003e Use cable ties or mounting clips to secure excess cable length, ensuring a minimum bend radius of 25.4 mm is strictly maintained to prevent signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Designed to meet stringent industrial electrical standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e RoHS compliant; supports long-term operational sustainability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Compatibility:\u003c\/strong\u003e When used as part of an integrated 3300 XL NSv system, components adhere to global hazardous location requirements (Consult the specific system documentation for valid system-level certificates).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666562117995,"sku":"330930-065-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-00-00-3300-nsv-extension-cable-yavlycns3zx_47988cba-8252-46cf-b99a-8137f54bf5b6.jpg?v=1765440669"},{"product_id":"bently-nevada-330130-070-03-00-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-070-03-00 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-070-03-00\u003c\/strong\u003e specifies a 7.0-meter \u003cstrong\u003e3300 XL standard extension cable\u003c\/strong\u003e with FEP armored protection, a pre-installed connector protector, and no hazardous area approvals. This assembly acts as an electrical bridge within a machinery protection system, connecting a 3300 XL 8 mm proximity probe to a 3300 XL Proximitor sensor. It utilizes gold-plated coaxial ClickLoc connectors, featuring a locking mechanism that secures connections without requiring special tools.\u003c\/p\u003e\n\u003cp\u003eThe integrated FEP-jacketed armor protects the inner transmission cable against mechanical wear, physical damage, and abrasive industrial environments. Additionally, the fluorosilicone connector protector provides enhanced environmental sealing, preventing moisture and contaminants from degrading the coaxial connection. This specific 7.0-meter variant is commonly paired with a 2.0-meter proximity probe to form a complete 9.0-meter transducer system length.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e7.0 meters (22.9 feet) overall cable length configuration.\u003c\/li\u003e\n\u003cli\u003eStainless steel armored sheath with FEP jacketing provides physical protection in high-abrasion environments.\u003c\/li\u003e\n\u003cli\u003ePre-installed fluorosilicone connector protector shields the coaxial union from liquid ingress and dust.\u003c\/li\u003e\n\u003cli\u003eGold-plated coaxial ClickLoc male and female connectors prevent accidental loosening via a tactile locking mechanism.\u003c\/li\u003e\n\u003cli\u003e75 ohm nominal system impedance matches standard 3300 XL 8 mm transducer components.\u003c\/li\u003e\n\u003cli\u003eOperating temperature range of -52 degC to +177 degC for industrial applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection systems (TSI) for steam turbines, gas turbines, and compressors.\u003c\/li\u003e\n\u003cli\u003eNon-contact shaft vibration and axial position measurement.\u003c\/li\u003e\n\u003cli\u003eHydroelectric generators and large industrial electric motor bearing monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330130-070-03-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable, Armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length Option\u003c\/td\u003e\n\u003ctd\u003e070\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (22.9 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Connector Protector and Cable Option\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eArmored cable with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n\u003ctd\u003e330130-070-03-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.72 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e260 mm x 260 mm x 45 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFEP coaxial with stainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (22.9 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial gold-plated ClickLoc (male\/female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Resistance (R_CORE)\u003c\/td\u003e\n\u003ctd\u003e1.54 +\/- 0.23 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Resistance (R_JACKET)\u003c\/td\u003e\n\u003ctd\u003e0.46 +\/- 0.09 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Diameter of Armor\u003c\/td\u003e\n\u003ctd\u003e7.67 mm max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Diameter of Cable\u003c\/td\u003e\n\u003ctd\u003e3.70 mm max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Resistance\u003c\/td\u003e\n\u003ctd\u003eLess than 3% change in Average Scale Factor (ASF) in 93% humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMale Connector\u003c\/td\u003e\n\u003ctd\u003eConnects to 3300 XL 8 mm Proximity Probe (ClickLoc coaxial interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFemale Connector\u003c\/td\u003e\n\u003ctd\u003eConnects to 3300 XL Proximitor Sensor (ClickLoc coaxial interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the extension cable length and the probe length, when added together, match the required total length of the Proximitor sensor (typically 9.0 meters for this 7.0-meter extension cable configuration).\u003c\/li\u003e\n\u003cli\u003eConnectors should be tightened finger-tight until they click. Do not use pliers unless mating to a non-XL stainless steel connector.\u003c\/li\u003e\n\u003cli\u003eSecure the armored run using appropriate cable clamps or conduit to prevent mechanical fatigue and excessive motion in high-vibration environments.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum bend radius of 38.1 mm (1.5 in) for armored cable paths to prevent internal coaxial damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eCE Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666563821931,"sku":"330130-070-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-070-03-00-extension-cable-2dak1rkkgms_80854efc-44a7-45cd-9b3b-2e24ba9cac29.jpg?v=1765440705"},{"product_id":"bently-nevada-330930-040-03-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-040-03-05 3300 NSv Extension Cable","description":"\u003cp\u003eThe \u003cstrong\u003e330930-040-03-05\u003c\/strong\u003e is a \u003cstrong\u003e3300 NSv Extension Cable\u003c\/strong\u003e designed for use within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This extension cable serves as a critical component in systems designed for centrifugal air compressors, refrigeration compressors, and process gas compressors, particularly in installations where space constraints (such as counter bore or side-view limitations) restrict the use of standard transducer systems. The \u003cstrong\u003e3300 NSv\u003c\/strong\u003e extension cable is mechanically and electrically compatible with Bently Nevada's previous 3300 RAM proximity transducer components.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Mechanically and electrically compatible and interchangeable with previous 3300 RAM proximity extension cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Design:\u003c\/strong\u003e Features gold-plated brass \u003cstrong\u003eClickLoc\u003c\/strong\u003e connectors that lock into place to prevent loosening during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e Designed for robust performance with high-quality coaxial cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Includes a connector protector (as specified in this model code) to prevent liquids from entering the \u003cstrong\u003eClickLoc\u003c\/strong\u003e connectors and affecting electrical signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Designed to work as part of the 3300 XL NSv system, which features an Average Scale Factor of 7.87 V\/mm (200 mV\/mil).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3300 XL NSv\u003c\/strong\u003e transducer system is typically utilized in the following fluid-filmed bearing machine applications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration and radial position measurements \u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements \u003c\/li\u003e\n\u003cli\u003eTachometer and zero speed measurements \u003c\/li\u003e\n\u003cli\u003ePhase reference (Keyphasor signals) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330930-040-03-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3300 NSv Extension Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\/Cable Option\u003c\/td\u003e\n\u003ctd\u003eWithout stainless steel armor, with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 or 7 meters (including extension cable and probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtension Cable Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 N (50 lb) at probe lead to extension cable connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtension Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Ensure the combined length of the extension cable and the probe matches the required 3300 XL NSv Proximitor Sensor total system length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e While components are robust, take standard precautions to avoid electrostatic discharge during handling of connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Utilize the included connector protectors on the probe-to-extension cable and cable-to-Proximitor Sensor connections to prevent liquid ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque:\u003c\/strong\u003e ClickLoc connectors should be finger-tightened to ensure proper locking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e For the Proximitor Sensor, use three-conductor shielded triad cable (0.2 to 1.5 mm2) with a maximum length of 305 meters (1,000 feet) to the monitor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666563854699,"sku":"330930-040-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-040-03-05-3300-nsv-extension-cable-aukkvrnthvg_0ac9b12c-a2e0-4109-8bf7-5e8b2bc3d2e3.jpg?v=1765440707"},{"product_id":"bently-nevada-106765-4-interconnect-cable","title":"Bently Nevada 106765-4 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cstrong\u003e106765-4\u003c\/strong\u003e is an interconnect cable assembly designed for use with the Bently Nevada 330525 Velomitor XA piezo-velocity sensor. This cable provides reliable signal transmission between the sensor and monitoring systems in industrial environments. The 106765 series is engineered to support the extended application requirements of the Velomitor XA, ensuring signal integrity for machinery vibration monitoring.\n\nThis specific configuration, \u003cstrong\u003e106765-4\u003c\/strong\u003e, denotes an interconnect cable with a defined length. The assembly features a 2-conductor twisted, shielded design to minimize electromagnetic interference. It is compatible with environmental protection measures, including splash-resistant boot covers, when installed to maintain system IP-65 and NEMA 4X requirements.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned specifically for the Bently Nevada 330525 Velomitor XA sensor\u003c\/li\u003e\n\u003cli\u003e2-conductor twisted, shielded cable construction\u003c\/li\u003e\n\u003cli\u003eProvides reliable connectivity in moist or harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eCompatible with stainless steel armor options for enhanced mechanical protection\u003c\/li\u003e\n\u003cli\u003eSupports integration into machinery monitoring chains without requiring custom housings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRotating machinery vibration monitoring\u003c\/li\u003e\n\u003cli\u003eCasing vibration measurements\u003c\/li\u003e\n\u003cli\u003eHarsh industrial environments requiring moisture resistance\u003c\/li\u003e\n\u003cli\u003eRemote sensor-to-monitor signal routing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e106765-4\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable for 330525 Velomitor XA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Length\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eLength in meters (per system reference: 12.0 meters \/ 39.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e106765-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e2-conductor, twisted, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m (3.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Length\u003c\/td\u003e\n\u003ctd\u003e25.0 m (82 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e330525 Velomitor XA Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the cable is routed away from high-voltage power lines to prevent induced noise.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum bend radius of 1.5 in to prevent damage to the internal conductors.\u003c\/li\u003e\n\u003cli\u003eUse appropriate splash-resistant boots and clamps to secure the cable assembly at the sensor connection point if the installation is exposed to moisture.\u003c\/li\u003e\n\u003cli\u003eVerify all connections are tight and that the shield is properly terminated at the monitor end to maintain noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565460331,"sku":"106765-4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-106765-4-interconnect-cable-le3gcgshjap_94e6f44b-92e8-4987-a817-ca23a1f5c2ea.jpg?v=1765440727"},{"product_id":"bently-nevada-16710-14-interconnect-cable","title":"Bently Nevada 16710-14 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16710-14\u003c\/strong\u003e is a 14 ft (4.27 m) interconnect cable assembly designed for use with Bently Nevada 330400 and 330425 series acceleration transducers. This 3-conductor shielded 22 AWG (0.5 mm2) cable provides a reliable interface for casing vibration monitoring in industrial environments. It features a 3-socket plug connector on one end for attachment to the accelerometer, while the other end is terminated with lugs for installation into instrumentation housing or connection blocks.\u003c\/p\u003e\n\u003cp\u003eThis cable is built to maintain signal integrity for critical machinery applications. The shielded design minimizes electromagnetic interference, ensuring accurate transmission of vibration data from the sensor to the monitoring system. It is suitable for diverse industrial settings where continuous monitoring of gear mesh or bearing housing acceleration is required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e14 ft (4.27 m) total cable length\u003c\/li\u003e\n\u003cli\u003e3-conductor shielded 22 AWG (0.5 mm2) construction\u003c\/li\u003e\n\u003cli\u003e3-socket plug connector (sensor end)\u003c\/li\u003e\n\u003cli\u003eTerminal lugs (instrumentation end)\u003c\/li\u003e\n\u003cli\u003eCompatible with 330400 and 330425 acceleration transducers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCasing acceleration monitoring\u003c\/li\u003e\n\u003cli\u003eGear mesh monitoring\u003c\/li\u003e\n\u003cli\u003eBearing housing vibration measurement\u003c\/li\u003e\n\u003cli\u003eRotating machinery protection in oil and gas, power generation, and petrochemical facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e16710-14\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded 22 AWG cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length Option\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e14.0 ft (4.27 m) length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e16710-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded, 22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e14.0 ft (4.27 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Connector\u003c\/td\u003e\n\u003ctd\u003e3-socket plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Transducers\u003c\/td\u003e\n\u003ctd\u003e330400, 330425 Accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eStandard installation for these cables involves routing through protective conduit to prevent physical damage and electrical interference. The cable should be kept away from high-voltage lines. Ensure the 3-socket plug is fully seated on the accelerometer to maintain environmental sealing. When terminating the lugs, ensure proper torque and connection to the monitoring system ground reference as specified in the accelerometer user guide.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565951851,"sku":"16710-14","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-14-interconnect-cables-a1wc5knjqkw_92a679a8-2426-4ffb-a444-3a6e9828d27a.jpg?v=1765440737"},{"product_id":"bently-nevada-16925-99-interconnect-cable","title":"Bently Nevada 16925-99 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e16925-99\u003c\/strong\u003e is a 3-conductor shielded 22 AWG (0.5 mm2) interconnect cable designed for use with Bently Nevada 330400 and 330425 accelerometers. This specific configuration features a 3-socket plug at one end for sensor connection and terminal lugs at the opposing end for integration into monitoring systems or junction boxes. The -99 suffix denotes a 99 ft (30.0 m) total cable length, providing the reach required for routing signals in industrial environments while maintaining signal integrity.\n\nThis cable assembly is engineered to facilitate reliable vibration and acceleration data transmission in critical machinery monitoring applications. The shielded design minimizes electromagnetic interference, ensuring accurate signal fidelity between the transducer and the monitoring equipment.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard 3-conductor shielded 22 AWG (0.5 mm2) construction\u003c\/li\u003e\n\u003cli\u003e3-socket MIL-C-5015 style plug for direct sensor mating\u003c\/li\u003e\n\u003cli\u003eTerminal lugs at the non-connector end for simplified field wiring\u003c\/li\u003e\n\u003cli\u003eTotal length of 99 ft (30.0 m)\u003c\/li\u003e\n\u003cli\u003eDesigned for compatibility with 330400 and 330425 acceleration transducers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCritical machinery casing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eGear mesh monitoring\u003c\/li\u003e\n\u003cli\u003eRotating equipment protection systems\u003c\/li\u003e\n\u003cli\u003eIndustrial acceleration and velocity sensing chains\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e16925-99\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable, 3-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Length (feet)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003ctd\u003e99 ft (30.0 m) total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e16925-99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3-conductor, shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector (Sensor End)\u003c\/td\u003e\n\u003ctd\u003e3-socket plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination (System End)\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e99 ft (30.0 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e330400 \/ 330425 Accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the sensor-end connector securely onto the accelerometer, ensuring the connection is clean and properly seated.\u003c\/li\u003e\n\u003cli\u003eRoute the cable through protected conduit where possible to prevent mechanical damage in industrial environments.\u003c\/li\u003e\n\u003cli\u003eEnsure the cable shield is grounded correctly at the monitoring system end to maintain noise immunity.\u003c\/li\u003e\n\u003cli\u003eMaintain the minimum bend radius during installation to prevent internal conductor damage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566017387,"sku":"16925-99","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16925-99-interconnect-cable-wcitn50d1do_915e52bb-16a1-4ccb-8663-b7fec5e479d1.jpg?v=1765440738"},{"product_id":"bently-nevada-106765-06-interconnect-cable","title":"Bently Nevada 106765-06 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e106765-06\u003c\/strong\u003e is an interconnect cable assembly designed for use with the Bently Nevada 330525 Velomitor XA (eXtended Application) piezoelectric velocity sensor. This cable provides the necessary signal transmission path in harsh industrial environments where moisture and weather protection are critical. The assembly features a 6 metre length (Option 06) and is compatible with the Velomitor XA sensor's ruggedized connector system, ensuring signal integrity in non-housed installations.\n\nThis interconnect cable is engineered to maintain low noise and high signal fidelity across the frequency response range of the Velomitor XA sensor. When paired with the 330525 sensor, the system meets IP-65 and NEMA 4X requirements, providing a robust solution for machinery vibration monitoring in challenging, moisture-prone conditions.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6 metre cable length (Option 06)\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for 330525 Velomitor XA sensor integration\u003c\/li\u003e\n\u003cli\u003eRuggedized construction for use in non-housed, moisture-rich industrial environments\u003c\/li\u003e\n\u003cli\u003eCompatible with Bently Nevada splash-resistant boot covers and clamps\u003c\/li\u003e\n\u003cli\u003eShielded construction to minimize electromagnetic interference\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial machinery vibration monitoring\u003c\/li\u003e\n\u003cli\u003eFluid handling and outdoor rotating equipment\u003c\/li\u003e\n\u003cli\u003eApplications requiring NEMA 4X or IP-65 environmental protection\u003c\/li\u003e\n\u003cli\u003eRemote vibration sensing where housing is not feasible\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eOption\u003c\/th\u003e\n    \u003cth\u003eCode on This SKU\u003c\/th\u003e\n    \u003cth\u003eDescription\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n    \u003ctd\u003e106765-06\u003c\/td\u003e\n    \u003ctd\u003eInterconnect Cable for 330525 Velomitor XA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eA - Length in metres\u003c\/td\u003e\n    \u003ctd\u003e06\u003c\/td\u003e\n    \u003ctd\u003e6.0 metres (19.7 feet)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eParameter\u003c\/th\u003e\n    \u003cth\u003eSpecification\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eManufacturer\u003c\/td\u003e\n    \u003ctd\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePart Number\u003c\/td\u003e\n    \u003ctd\u003e106765-06\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProduct Type\u003c\/td\u003e\n    \u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCompatible Sensor\u003c\/td\u003e\n    \u003ctd\u003e330525 Velomitor XA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eConductor\u003c\/td\u003e\n    \u003ctd\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCable Construction\u003c\/td\u003e\n    \u003ctd\u003e2 conductor, twisted, shielded\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n    \u003ctd\u003e38.1 mm (1.5 in)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd\u003e-55 degC to +121 degC (-67 degF to +250 degF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\nEnsure the cable is routed away from high-voltage power lines to minimize electromagnetic interference (EMI). When installing in moisture-prone areas, use the appropriate splash-resistant boot covers and clamps to maintain the IP-65\/NEMA 4X seal at the sensor connector junction. Observe the minimum bend radius of 38.1 mm (1.5 in) to prevent damage to the internal conductors.\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\nThe 330525 Velomitor XA system (with which this cable is used) holds multiple hazardous area approvals, including CSA\/NRTL\/C and ATEX\/IECEx. Please verify that the specific installation location requirements are met by the sensor system's total certification status.","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566082923,"sku":"106765-06","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-106765-06-interconnect-cable-p5kjehi2c4x_fe1ce901-5ba7-4dda-8a71-33c028c62e27.jpg?v=1765440739"},{"product_id":"bently-nevada-16925-12-330400-series-interconnect-cables","title":"Bently Nevada 16925-12 330400 Series Interconnect Cables","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16925-12\u003c\/strong\u003e specifies a 12-foot (3.6 m) 3-conductor shielded 22 AWG (0.5 mm2) interconnect cable, configured with a 3-socket plug at one end and terminal lugs at the other end. This configuration is used for transmitting high-frequency vibration signals from Bently Nevada 330400 and 330425 accelerometer transducers to permanent monitoring systems or dynamic signal analyzers.\u003c\/p\u003e\n\u003cp\u003eThe cable features a 22 AWG (0.5 mm2) conductor size, a protective shield to minimize electromagnetic interference (EMI), and terminal lugs for secure termination at the cabinet or receiver end. Unlike the heavier 18 AWG variant (130539) or the armored version (16710), the 16925 cable series provides a lightweight and flexible cabling option for standard industrial installations within protective conduit or enclosures. The 12-foot length is standard-configured to support intermediate-distance routing between the sensor and local junction boxes.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Configuration:\u003c\/strong\u003e 3-conductor shielded cable featuring 22 AWG (0.5 mm2) wire size for optimal signal integrity in high-frequency vibration monitoring applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 12 ft (3.6 m) standard length, providing the ideal distance for field installations requiring run-ups from bearing housings to local enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminations:\u003c\/strong\u003e 3-socket plug connection at one end to mate directly with 330400\/330425 sensors, and terminal lugs at the opposing end for terminal block integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Mitigation:\u003c\/strong\u003e Integrated shielding protects delicate dynamic signals against electromagnetic and radio-frequency interference (EMI\/RFI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Routing:\u003c\/strong\u003e Lightweight construction allows for easier bending and pulling through protective conduits or cable trays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is deployed across critical rotating machinery in demanding industrial environments, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Generation: Steam, gas, and hydro turbine bearing casing monitoring.\u003c\/li\u003e\n\u003cli\u003eOil and Gas: Centrifugal compressors, pumps, and gearboxes where casing acceleration is monitored.\u003c\/li\u003e\n\u003cli\u003ePetrochemical: Reciprocating machinery and fans requiring API 670 compliant measurements.\u003c\/li\u003e\n\u003cli\u003eGeneral Industrial: Balance of plant rotating machinery casing vibration protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\/Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16925-12\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded 22 AWG interconnect cable (12 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption A (Cable Length)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12 ft (3.6 m) standard length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16925-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded interconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 ft (3.6 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnd A Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-socket plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnd B Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Transducers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 330400 and 330425 Accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 ft (0.6 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure precise signal transmission and reliable operation in heavy industrial applications, follow these physical routing and electrical termination practices:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Protection:\u003c\/strong\u003e Install the interconnect cable in a protective conduit or dedicated cable trays to guard against mechanical damage, cutting, or crushing in harsh environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Avoid routing the signal cable adjacent to high-voltage power lines or variable frequency drive (VFD) cables to prevent electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the cable shield is properly terminated at the monitoring system or local junction box terminal strip to maintain a single-point ground, preventing ground loop noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating Integrity:\u003c\/strong\u003e Ensure the 3-socket plug is fully threaded and seated onto the accelerometer connector. It is recommended to implement IP54 ingress protection or better at the mating point for outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566115691,"sku":"16925-12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16925-12-interconnect-cable-4aabcfcibnj_f0de65f3-23ff-4cdc-a633-744fcd38ce79.jpg?v=1765440740"},{"product_id":"bently-nevada-330130-080-10-00-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-080-10-00 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-080-10-00\u003c\/strong\u003e: 3300 XL standard \u003cstrong\u003eextension cable\u003c\/strong\u003e configuration, featuring an 8.0 m cable length, FluidLoc cable option, and no agency approval requirements. This configuration functions as a link in the 3300 XL 8 mm proximity transducer system, connecting the proximity probe to the Proximitor sensor. It utilizes gold-plated coaxial connectors to maintain signal integrity for shaft vibration, displacement, and position measurements in rotating machinery.\u003c\/p\u003e\n\n\u003cp\u003eThis configuration differs from standard 3300 XL cables in its use of the FluidLoc option (Option 10), which prevents lubricating oil or other process fluids from migrating through the interior of the cable. Unlike armored configurations or standard standard cables, this variant provides an unarmored FluidLoc barrier without a connector protector. It is typically selected for machinery installations where physical conduit provides mechanical protection, but fluid sealing along the cable run is necessary to prevent leakage outside the machine casing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCable Length Option: 8.0 meters (26.2 feet) total length, designed to form a 9.0-meter system when combined with a 1.0-meter probe.\u003c\/li\u003e\n  \u003cli\u003eFluidLoc Technology (Option 10): Internal block design prevents wicking of oils and process liquids through the interior of the triaxial cable.\u003c\/li\u003e\n  \u003cli\u003eFluorinated Ethylene Propylene (FEP) Insulation: High chemical resistance and thermal stability across industrial environments.\u003c\/li\u003e\n  \u003cli\u003eClickLoc Gold-Plated Connectors: Male and female miniature coaxial connectors provide corrosion resistance and secure, finger-tight locking.\u003c\/li\u003e\n  \u003cli\u003eHigh Pull Strength: Patented CableLoc design provides up to 330 N (75 lbf) of pull strength to protect the connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial rotating machinery including steam turbines, gas turbines, centrifugal compressors, and generators.\u003c\/li\u003e\n  \u003cli\u003eEnvironments where process fluids or lubricating oils are present and must be prevented from leaking along the cable routing.\u003c\/li\u003e\n  \u003cli\u003eRetrofits and new installations of 3300 XL 8 mm proximity transducer systems requiring a 9.0-meter total system length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse: collapse; border: 1px solid #ccc; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-080-10-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable, FluidLoc configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e080\u003c\/td\u003e\n      \u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Connector Protector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc cable, no connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSuffix -CN Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot Present\u003c\/td\u003e\n      \u003ctd\u003eChina hazardous area approval package (NEPSI, CCC) - Not included in this configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse: collapse; border: 1px solid #ccc; width: 100%;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-080-10-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc triaxial cable (prevents fluid migration through cable interior)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 mm (0.155 in) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated miniature coaxial ClickLoc connectors (1 male, 1 female)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Max Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.24 mm (0.285 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFinger tight (clicks when fully locked)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +177 degC (-60 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePull Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) maximum pull strength\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFluorinated Ethylene Propylene (FEP) jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.27 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e300 mm x 300 mm x 40 mm (H x W x D) (coiled packaging)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse: collapse; border: 1px solid #ccc; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth\u003eConnector Side\u003c\/th\u003e\n      \u003cth\u003eConnector Gender\u003c\/th\u003e\n      \u003cth\u003eTarget Connection Profile\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Connection Side\u003c\/td\u003e\n      \u003ctd\u003eMiniature Female Coaxial ClickLoc\u003c\/td\u003e\n      \u003ctd\u003eConnects to the miniature male coaxial connector on the 3300 XL proximity probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Connection Side\u003c\/td\u003e\n      \u003ctd\u003eMiniature Male Coaxial ClickLoc\u003c\/td\u003e\n      \u003ctd\u003eConnects to the female coaxial terminal on the 3300 XL Proximitor sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInstall the 3.94 mm cable through protective conduit to safeguard against physical damage, mechanical wear, or sharp bends.\u003c\/li\u003e\n  \u003cli\u003eHand-tighten the gold-plated ClickLoc connectors until they click; do not use pliers or other tools unless joining with a non-XL stainless steel connector.\u003c\/li\u003e\n  \u003cli\u003eVerify that the total combined length of the probe and this 8.0-meter extension cable matches the 9.0-meter calibration of the paired Proximitor sensor.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum bend radius of 25.4 mm (1.0 in) along the entire cable run.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE compliant (satisfies European RFI\/EMI immunity when paired with the 3300 XL Proximitor sensor).\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant.\u003c\/li\u003e\n  \u003cli\u003eNote on hazardous areas: This specific configuration (-00 approval option) does not carry hazardous area certifications. For Chinese hazardous area certifications (NEPSI and CCC), the optional -CN suffix package must be specified.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566639979,"sku":"330130-080-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-080-10-00-extension-cable-erzjrvyutfv_bc9359a1-93cd-4d3d-a9af-adb5a377f0ac.jpg?v=1765440755"},{"product_id":"bently-nevada-330130-065-00-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-065-00-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-065-00-05\u003c\/strong\u003e: 3300 XL Standard Extension Cable, 6.5 m length (Option 065), standard cable construction (Option 00), and CSA\/ATEX\/IECEx hazardous area approvals (Option 05). This extension cable serves as a critical link in the 3300 XL 8 mm Proximity Transducer System, connecting the probe to the Proximitor sensor for non-contact eddy-current displacement measurement.\u003c\/p\u003e\n\n\u003cp\u003eThe 3300 XL system ensures that the total system length (probe + extension cable) matches the Proximitor sensor calibration requirements, maintaining measurement accuracy for shaft vibration and axial position monitoring in critical rotating machinery such as turbines, compressors, and pumps.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6.5 m cable length for optimized reach between probe and monitor housing\u003c\/li\u003e\n\u003cli\u003eStandard construction (non-armored) suitable for typical industrial environments\u003c\/li\u003e\n\u003cli\u003eOption 05 agency approvals allow for installation in hazardous areas (CSA, ATEX, IECEx)\u003c\/li\u003e\n\u003cli\u003eEngineered for use with 3300 XL 8 mm proximity probes and Proximitor sensors\u003c\/li\u003e\n\u003cli\u003eMaintains system signal integrity for precise displacement and vibration data\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHydrocarbon and chemical processing plants\u003c\/li\u003e\n\u003cli\u003ePower generation and turbine-generator sets\u003c\/li\u003e\n\u003cli\u003eCompressor and centrifugal pump monitoring\u003c\/li\u003e\n\u003cli\u003eCritical rotating machinery protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330130-065-00-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3300 XL Standard Extension Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length\u003c\/td\u003e\n\u003ctd\u003e065\u003c\/td\u003e\n\u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Cable Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330130-065-00-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e6.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard (non-armored)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the total length of the 3300 XL probe and extension cable matches the calibrated length of the Proximitor sensor (typically 5 m or 9 m). Use proper cable routing practices to avoid mechanical strain or abrasion. In hazardous area applications, ensure installation adheres to all local codes regarding intrinsic safety and barrier requirements associated with the CSA\/ATEX\/IECEx certifications.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis product is certified for hazardous environments under CSA, ATEX, and IECEx approvals when configured with Option 05. Consult the product documentation and Bently Nevada Approvals Quick Reference Guide (108M1756) for specific installation requirements related to these certifications.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666567328107,"sku":"330130-065-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-065-00-05-3300-xl-extension-cable-ggwy3lxwv5l_39d1e576-f477-4365-b6fe-d9ef73a55f92.jpg?v=1765440767"},{"product_id":"bently-nevada-330730-080-10-05-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-080-10-05 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 080 (8.0 meters length), Option 10 (FluidLoc cable), and Option 05 (Multiple Approvals) specify this \u003cstrong\u003e330730-080-10-05\u003c\/strong\u003e \u003cstrong\u003e3300 XL 11 mm Extension Cable\u003c\/strong\u003e configuration.\u003c\/p\u003e\n\u003cp\u003eThis cable provides non-contact eddy-current displacement measurement within 3300 XL 11 mm monitoring chains. It connects a compatible 3300 XL 11 mm proximity probe to a 330780 Proximitor Sensor. The FluidLoc cable construction prevents moisture, oil, and other process fluids from leaking or wicking through the cable jacket, protecting the Proximitor sensor housing in harsh industrial environments. With the multiple approvals option (Option 05), this configuration is certified for use in hazardous areas.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8.0 meters (26.2 feet) overall cable length option\u003c\/li\u003e\n  \u003cli\u003eFluidLoc cable design to prevent moisture and fluid wicking\u003c\/li\u003e\n  \u003cli\u003eMultiple Approvals certification (Option 05) for hazardous locations\u003c\/li\u003e\n  \u003cli\u003eFEP (fluorinated ethylene propylene) insulation\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass miniature ClickLoc coaxial connectors\u003c\/li\u003e\n  \u003cli\u003e75 Ohm triaxial cable impedance\u003c\/li\u003e\n  \u003cli\u003e25.4 mm (1.0 in) minimum bend radius\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTurbine and compressor shaft vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eAxial (thrust) position measurements on steam turbines\u003c\/li\u003e\n  \u003cli\u003eRamp differential expansion measurements on rotating machinery\u003c\/li\u003e\n  \u003cli\u003eRod position or rod drop measurements on reciprocating compressors\u003c\/li\u003e\n  \u003cli\u003eCritical rotating machinery protection on 11 mm probe systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330730-080-10-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length Option\u003c\/td\u003e\n      \u003ctd\u003e080\u003c\/td\u003e\n      \u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc cable (unarmored, without connector protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including ATEX, IECEx, and CSA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (a Baker Hughes business)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330730-080-10-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial, FEP insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc (seals against oil and moisture wicking)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUnarmored\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClickLoc coaxial\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance (Core Conductor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.6 +\/- 0.2 ohms (8.0 m cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance (Coaxial Conductor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 +\/- 0.5 ohms (8.0 m cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperature Range (Operating and Storage)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Rated Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 pounds) at probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector-to-Connector Torque (Recommended)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFinger tight\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector-to-Connector Torque (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.565 N-m (5 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eKeep ClickLoc connectors clean, dry, and free of dust or process oils during the installation process.\u003c\/li\u003e\n  \u003cli\u003eJoin the probe lead and extension cable connectors, twisting them finger tight (maximum torque of 0.565 N-m).\u003c\/li\u003e\n  \u003cli\u003eObserve the minimum bend radius limit of 25.4 mm (1.0 in) during cable routing to prevent internal conductor damage.\u003c\/li\u003e\n  \u003cli\u003eEnsure that the sum of the probe length and the extension cable length equals the designated total length of the compatible Proximitor Sensor.\u003c\/li\u003e\n  \u003cli\u003eUse silicone tape or connector protectors in areas exposed to harsh fluids, excluding environments with turbine oil where silicone tape is not recommended.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eATEX\/IECEx\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc; Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCSA\/NRTL\/C\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClass I, Zone 0, AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCE Mark\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCompliant with EMC Directive 2014\/30\/EU; RoHS Directive 2011\/65\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eChina RoHS\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEFUP designation of 15 years in accordance with SJ\/T 11364-2024\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSIL 2 (HFT = 0), SIL 3 (HFT = 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666568409451,"sku":"330730-080-10-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330730-080-10-05-extension-cable-iunuqvobttl_8eee33c9-dba6-4de3-951c-195f9f71720a.jpg?v=1765440785"},{"product_id":"bently-nevada-84661-40-standard-armored-interconnect-cable","title":"Bently Nevada 84661-40 Standard Armored Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e84661-40\u003c\/strong\u003e is a standard armored interconnect cable designed for Bently Nevada High Temperature Velomitor (HTVS) systems. This specific configuration features a 40-foot (12.2 m) length of shielded 0.382 mm2 (22 AWG) cable protected by stainless steel armor, which provides mechanical protection against abrasion and physical damage in demanding industrial environments.\u003c\/p\u003e\n\n\u003cp\u003eThe cable is equipped with a moisture-resistant female connector at the HTVS transducer end and ring lugs at the monitor end, ensuring reliable signal transmission for vibration monitoring applications. By utilizing this armored cabling, operators can extend the HTVS sensor's reach while maintaining signal integrity in areas where cables are exposed to potential impact, debris, or harsh industrial conditions.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e40-foot (12.2 m) total cable length\u003c\/li\u003e\n\u003cli\u003eStainless steel armor for enhanced abrasion and crush resistance\u003c\/li\u003e\n\u003cli\u003eShielded 0.382 mm2 (22 AWG) wire for noise reduction\u003c\/li\u003e\n\u003cli\u003eMoisture-resistant female connector (HTVS end)\u003c\/li\u003e\n\u003cli\u003eRing lug termination (Monitor end)\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: -29 C to 121 C (-20 F to 250 F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-temperature machinery casing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eCritical rotating machinery protection where cabling requires mechanical armor\u003c\/li\u003e\n\u003cli\u003eIndustrial environments with high risk of cable abrasion or physical impact\u003c\/li\u003e\n\u003cli\u003ePower generation, oil and gas, and petrochemical facility assets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e84661-40\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Length\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e40 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e84661-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eShielded twisted pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector (Sensor End)\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination (Monitor End)\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-29 C to 121 C (-20 F to 250 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e51 mm (2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the cable is routed in a way that minimizes exposure to extreme heat sources beyond the specified 121 C limit for the cable. Use appropriate cable clamps and stainless steel ties to secure the armored cable and prevent strain on the connectors. When installing in hazardous areas, ensure the complete monitoring loop (transducer, cable, and monitor) complies with local electrical codes and the specific agency approvals required for the installation site.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666568606059,"sku":"84661-40","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-84661-40-interconnect-cable-fpp3rxswffv_c6912b53-b12f-4457-b93f-e68529245131.jpg?v=1765440790"},{"product_id":"bently-nevada-330130-130-02-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-130-02-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330130-130-02-05\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Standard Extension Cable\u003c\/strong\u003e designed for use within 3300 XL 8 mm proximity transducer systems. This specific configuration features a 13.0 meter (Option 130) cable length, standard cable construction (Option 02), and is rated for CSA, ATEX, and IECEx hazardous area approvals (Option 05). It acts as an integral link between the 3300 XL proximity probe and the 3300 XL Proximitor sensor, ensuring the total system length remains consistent with the calibrated requirements of the transducer chain.\u003c\/p\u003e\n\n\u003cp\u003eThe 3300 XL extension cable incorporates the Bently Nevada ClickLoc connector design, which provides a secure, reliable connection while maintaining the electrical characteristics required for accurate, non-contact eddy-current displacement measurement. This extension cable is compatible with standard 3300 XL monitoring chains used for shaft vibration and axial position measurement on critical rotating machinery such as turbines, compressors, and large motors.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e13.0 meter (Option 130) total system length compatibility\u003c\/li\u003e\n\u003cli\u003eStandard cable construction (Option 02)\u003c\/li\u003e\n\u003cli\u003eCSA, ATEX, and IECEx agency approvals (Option 05)\u003c\/li\u003e\n\u003cli\u003eClickLoc connector interface for secure, consistent signal integrity\u003c\/li\u003e\n\u003cli\u003eMaintains system calibration accuracy when matched with appropriate 3300 XL probes and Proximitor sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eUsed for critical rotating machinery protection and condition monitoring in heavy industry environments, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower generation (steam, gas, and hydro turbines)\u003c\/li\u003e\n\u003cli\u003eOil and gas (centrifugal compressors, pumps)\u003c\/li\u003e\n\u003cli\u003ePetrochemical and chemical processing\u003c\/li\u003e\n\u003cli\u003eMining and mineral processing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330130-130-02-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003ctd\u003e13.0 meters (42.7 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Cable Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eStandard cable with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330130-130-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e13.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003eStandard temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis product meets international hazardous area standards, including CSA, ATEX, and IECEx, when ordered with the corresponding approval option (Option 05).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666569359723,"sku":"330130-130-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-130-02-05-cables-bqnwk1ni3vw_80cd0706-70a0-4398-a188-4f0f8f105a46.jpg?v=1765440809"},{"product_id":"bently-nevada-330930-060-02-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-060-02-05 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-060-02-05\u003c\/strong\u003e specifies this \u003cstrong\u003e3300 NSv extension cable\u003c\/strong\u003e configured with a 6.0-meter length, stainless steel armor protection without an FEP jacket, and multiple international hazardous area agency approvals. This option combination utilizes robust stainless steel armoring to protect the internal 75-ohm coaxial cable from abrasive wear, mechanical crushing, and environmental impacts while omitting the outer fluoropolymer sheath for installations where extra chemical-washdown protection is unnecessary.\u003c\/p\u003e\n\u003cp\u003eOperating as an intermediate link within the 3300 XL NSv Proximity Transducer System, the cable maintains electrical and mechanical compatibility with Bently Nevada 3300 NSv proximity probes and 330980 Proximitor sensors. The system is optimized for machinery vibration and shaft position measurements in applications with tight target geometries or restricted clearance, such as small-bore rotating equipment and aeroderivative gas turbines.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e6.0-meter (19.7 feet) cable length matching specific calibrated system length configurations.\u003c\/li\u003e\n  \u003cli\u003eStainless steel armor protection (without outer FEP jacket) shielding the inner coaxial line from physical damage and severe industrial wear.\u003c\/li\u003e\n  \u003cli\u003eAgency Approval Option 05 specifying multiple hazardous area certifications, including CSA, ATEX, and IECEx.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc coaxial connectors providing self-locking mechanics to prevent loosening during operation.\u003c\/li\u003e\n  \u003cli\u003e75-ohm characteristic impedance designed to maintain stable signal transmission without attenuation.\u003c\/li\u003e\n  \u003cli\u003ePatented CableLoc design compatibility withstanding high pulling forces up to 220 N (50 lb) at standard interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVibration and axial position monitoring in high-speed, small-bore turbocompressors.\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines and compact rotating machines with limited target geometries.\u003c\/li\u003e\n  \u003cli\u003eIndustrial gearboxes, pumps, and centrifuges requiring mechanical armoring against external physical hazards.\u003c\/li\u003e\n  \u003cli\u003eHazardous-area installations requiring intrinsically safe or non-incendive transducer loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Position\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330930-060-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable, Armored\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length Option\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eWith stainless steel armor, without FEP jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx, and NEPSI certifications)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-060-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExtension Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExtension Cable DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCenter Conductor: 0.220 ohms\/m (0.067 ohms\/ft)\u003cbr\u003eShield: 0.066 ohms\/m (0.020 ohms\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature female and male coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 g\/m (0.7 oz\/ft) typical for armored cable variants\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo maintain correct sensor system calibration, the combined length of the proximity probe and this extension cable must match the calibrated total length of the compatible Proximitor sensor (for example, pairing a 1.0-meter probe with this 6.0-meter extension cable to complete a 7.0-meter system). Ensure a minimum bend radius of 25.4 mm (1.0 in) is maintained along the entire cable path. Connectors must be mated finger-tight, with a maximum allowable connector-to-connector torque of 0.56 Nm (5 in lb). The use of silicone self-fusing tape or a connector protector kit is recommended to prevent fluid ingress at mated joints; however, silicone tape should not be used inside a machinery casing exposed to turbine oil.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe Multiple Approvals (05) option complies with major global hazardous area requirements for intrinsic safety, non-incendive, and non-sparking protection concepts. Standards include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T5...T1 Ga; Ex nA IIC T5...T1 Gc; Ex ec IIC T5...T1 Gc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDust Approvals:\u003c\/strong\u003e Ex ia IIIC T90 degC...T280 degC Dc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Class I, Division 1, Groups A, B, C, and D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666569458027,"sku":"330930-060-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-060-02-05-3300-nsv-extension-cable-ecvjlzowudp_59b214f4-5b04-4a77-84a7-a4445f95ea3b.jpg?v=1765440811"},{"product_id":"bently-nevada-330190-040-01-00-3300-xl-etr-extension-cable","title":"Bently Nevada 330190-040-01-00 3300 XL ETR Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330190-040-01-00\u003c\/strong\u003e is a 4.0-meter 3300 XL Extended Temperature Range (ETR) extension cable designed for demanding machinery protection and monitoring applications. As a critical component of the 3300 XL 8 mm Proximity Transducer System, this extension cable maintains signal integrity between the probe and the Proximitor sensor, even in environments where ambient temperatures exceed standard operating ranges.\u003c\/p\u003e\n\n\u003cp\u003eThis specific configuration features 4.0 meters of total length (Option 040) and includes protective armor (Option 01) to provide enhanced mechanical resistance against abrasion and damage in industrial environments. It is engineered for use with 3300 XL ETR probe systems and 3300 XL ETR Proximitor sensors, ensuring that the total system length remains calibrated for accurate shaft vibration and position measurements. Proper system length matching is required to maintain the specified performance of the transducer chain.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e4.0-meter length (Option 040)\u003c\/li\u003e\n    \u003cli\u003eArmored cable construction (Option 01) for increased durability and mechanical protection\u003c\/li\u003e\n    \u003cli\u003eAgency Approval: Not required (Option 00)\u003c\/li\u003e\n    \u003cli\u003eExtended Temperature Range (ETR) compatibility for harsh industrial environments\u003c\/li\u003e\n    \u003cli\u003eClickLoc connector design for secure, reliable connection to 3300 XL series probes and Proximitor sensors\u003c\/li\u003e\n    \u003cli\u003eMaintains system calibration accuracy when paired with compatible ETR probes and Proximitor sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eGas and steam turbine monitoring\u003c\/li\u003e\n    \u003cli\u003eCentrifugal compressor shaft vibration and axial position\u003c\/li\u003e\n    \u003cli\u003eHydroelectric turbine monitoring\u003c\/li\u003e\n    \u003cli\u003eCritical rotating machinery in petrochemical and power generation facilities\u003c\/li\u003e\n    \u003cli\u003eHigh-temperature industrial environments where standard cables may degrade\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003cth\u003eOption\u003c\/th\u003e\n        \u003cth\u003eCode on This SKU\u003c\/th\u003e\n        \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n        \u003ctd\u003e330190-040-01-00\u003c\/td\u003e\n        \u003ctd\u003e3300 XL ETR Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eA - Cable Length\u003c\/td\u003e\n        \u003ctd\u003e040\u003c\/td\u003e\n        \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eB - Cable Option\u003c\/td\u003e\n        \u003ctd\u003e01\u003c\/td\u003e\n        \u003ctd\u003eArmored cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n        \u003ctd\u003e00\u003c\/td\u003e\n        \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003cth\u003eParameter\u003c\/th\u003e\n        \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eManufacturer\u003c\/td\u003e\n        \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003ePart Number\u003c\/td\u003e\n        \u003ctd\u003e330190-040-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eSystem Series\u003c\/td\u003e\n        \u003ctd\u003e3300 XL ETR\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eCable Length\u003c\/td\u003e\n        \u003ctd\u003e4.0 meters\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eCable Type\u003c\/td\u003e\n        \u003ctd\u003eArmored\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eConnector Type\u003c\/td\u003e\n        \u003ctd\u003eClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the extension cable length and the probe length, when added together, exactly match the required system length of the Proximitor sensor (e.g., 5.0m or 9.0m systems). Avoid sharp bends during cable routing to prevent damage to the internal coaxial structure. Cables should be secured using appropriate mounting hardware to minimize vibration-induced wear. In hazardous areas, refer to the site-specific installation control drawings and system documentation for grounding and shielding requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666570244459,"sku":"330190-040-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330190-040-01-00-3300-xl-etr-extension-cable-5yn11yea10o_c5b397fe-18d4-49f3-bff7-589530ee484c.jpg?v=1765440824"},{"product_id":"bently-nevada-16710-66-330400-interconnect-cable","title":"Bently Nevada 16710-66 330400 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 66 (66.0 ft cable length) specifies this 3-conductor shielded armored cable configuration — \u003cstrong\u003e16710-66\u003c\/strong\u003e, which serves as an \u003cstrong\u003einterconnect cable\u003c\/strong\u003e designed for Bently Nevada 330400 and 330425 accelerometer transducers.\u003c\/p\u003e\n\u003cp\u003eThis cable configuration incorporates integrated metal armor over 22 AWG (0.5 mm2) conductors, shielding delicate accelerometer signals from physical impact, abrasion, and electromagnetic interference. It is equipped with a 3-socket plug on the transducer connection end and terminal lugs on the receiver end, supporting direct connection to industrial monitor panels or junction boxes.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength Option 66:\u003c\/strong\u003e Provides 66.0 ft (20.1 m) of run length to handle mid-to-long distance physical separation between the transducer and junction box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Metal Armor:\u003c\/strong\u003e Offers heavy-duty protection against abrasive materials, crushing force, and impact in critical industrial settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielded 22 AWG Core:\u003c\/strong\u003e Combines low-resistance copper conductors with overall shielding to isolate and preserve clean vibration signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMIL-C-5015 Socket End:\u003c\/strong\u003e Features a durable 3-socket plug termination to match the heavy-duty threads of standard casing sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Lug Ends:\u003c\/strong\u003e Prepared with terminal lugs on the receiver end for rapid and secure screw terminal connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCasing acceleration and vibration measurements on rotating machinery such as gearboxes, steam turbines, gas turbines, and pumps.\u003c\/li\u003e\n\u003cli\u003eInterconnecting Bently Nevada 330400 or 330425 accelerometers with 3500 series vibration monitoring systems or intermediate junction boxes.\u003c\/li\u003e\n\u003cli\u003eEnvironments where mechanical hazards require armored cabling to prevent physical damage to critical signal paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Code\u003c\/th\u003e\n\u003cth\u003eThis SKU Value\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16710\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded 22 AWG armored interconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003ctd\u003e66 ft (approx. 20.1 m) length (ordered in increments of 1.0 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16710-66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Core Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated metal armor outer layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector A (Sensor End)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-socket plug (mates with 3-pin MIL-C-5015)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector B (Monitor End)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 ft (approx. 20.1 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 ft (0.9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Allowable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Accelerometers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 330400 and 330425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum System Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 305 m (1000 ft) with no signal degradation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the armored cable through protected environments or directly across mechanical supports where hazards exist. Avoid placing the cable near high-voltage lines or high electromagnetic sources to prevent signal interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Properly terminate the cable shield at the monitoring system or junction box terminal. Keep the shield isolated at the transducer end to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Bend Radius:\u003c\/strong\u003e Maintain the recommended bend radius of the metal armor during installation to prevent crimping the inner 22 AWG conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Assembly:\u003c\/strong\u003e Align and hand-tighten the 3-socket plug connector onto the MIL-C-5015 sensor receptacle, ensuring a snug and secure seal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e Environmental Protection Use Period (EFUP) designation of 15 years in accordance with SJ\/T 11364-2024.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666570441067,"sku":"16710-66","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-66-interconnect-cable-my0nqs1f4g0_86647a33-81bf-4c2d-91b8-cd77d30976ef.jpg?v=1765440828"},{"product_id":"bently-nevada-330130-080-12-00-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-080-12-00 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-080-12-00\u003c\/strong\u003e is an 8.0 meter standard extension cable for 3300 XL 8 mm proximity transducer systems, featuring a standard cable jacket (Option 12) with no agency approval (Option 00). This cable maintains electrical continuity within the transducer loop, connecting the proximity probe to the Proximitor sensor for continuous measurement of shaft vibration and axial position on critical rotating machinery.\u003c\/p\u003e\n\n\u003cp\u003eThis extension cable is engineered for the 3300 XL monitoring environment, utilizing the ClickLoc connector system to maintain a reliable interface. The standard construction provides consistent signal impedance, supporting the dynamic gap voltage transmission required for eddy-current monitoring chains.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8.0 meter total cable length (Option 080)\u003c\/li\u003e\n\u003cli\u003eStandard cable construction (Option 12)\u003c\/li\u003e\n\u003cli\u003eClickLoc connector interface for secure, vibration-resistant connections\u003c\/li\u003e\n\u003cli\u003eDesigned for compatibility with 3300 XL 8 mm proximity probes and Proximitor sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine machinery protection\u003c\/li\u003e\n\u003cli\u003eCentrifugal and axial compressor vibration monitoring\u003c\/li\u003e\n\u003cli\u003eRotor position and shaft displacement measurement\u003c\/li\u003e\n\u003cli\u003eCritical machinery monitoring in power generation and petrochemical facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption\u003c\/td\u003e\n\u003ctd\u003eCode on This SKU\u003c\/td\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330130-080-12-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length\u003c\/td\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Cable Option\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eStandard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330130-080-12-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Resistance\u003c\/td\u003e\n\u003ctd\u003e75 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Jacket Material\u003c\/td\u003e\n\u003ctd\u003eFluorinated Ethylene Propylene (FEP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eNone (Option 00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that extension cable routing avoids high-heat zones and areas with potential for mechanical abrasion. When installing, verify that the ClickLoc connectors are fully engaged to prevent signal intermittent issues. Standard installation practices require protecting the cable connectors from moisture and oil exposure during routing.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666570834283,"sku":"330130-080-12-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-080-12-00-3300-xl-standard-extension-cable-lywkwv0fpeb_79244742-2ffb-4a76-b466-86df8a70686d.jpg?v=1765440835"},{"product_id":"bently-nevada-330854-080-25-05-3300-xl-25-mm-extension-cable","title":"Bently Nevada 330854-080-25-05 3300 XL 25 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330854-080-25-05\u003c\/strong\u003e: 3300 XL 25 mm extension cable, Option 080 (8.0 m cable length), Option 25 (Armored High Temperature FluidLoc cable), Option 05 Multiple Approvals agency package. This cable is used to connect a 330851 25 mm proximity probe to a 330850 Proximitor Sensor, forming an integral part of the Bently Nevada 3300 XL 25 mm proximity transducer system.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration differs from standard unarmored alternatives by employing a flexible AISI 302 stainless steel armor sleeve with a protective PFA outer jacket. This construction shields the core 75-ohm triaxial FluidLoc cable from extreme mechanical environments, physical abrasion, and liquid ingress while preventing moisture or fluid migration into critical connector boundaries. The integrated gold-plated ClickLoc coaxial connections ensure signal impedance is perfectly preserved over the entire path, preventing frequency roll-off and calibration drift in demanding steam turbine differential expansion (DE) and thrust position monitoring applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 080 specifies an 8.0-metre (26.2 feet) total cable length, matched to specific probe and sensor calibration curves.\u003c\/li\u003e\n  \u003cli\u003eOption 25 features flexible AISI 302 stainless steel armor with a PFA outer jacket for high-durability routing.\u003c\/li\u003e\n  \u003cli\u003eOption 05 Multiple Approvals provides wide-ranging hazardous area certification compliance (CSA, ATEX, IECEx).\u003c\/li\u003e\n  \u003cli\u003ePFA insulated coaxial core resists temperatures up to 200 degC for high-pressure casing and steam paths.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass and beryllium copper ClickLoc connectors provide low-resistance, secure electrical coupling.\u003c\/li\u003e\n  \u003cli\u003eFluidLoc cable design prevents fluid transmission along the inner cable layers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDifferential expansion (DE) measurements on medium to large steam turbine generators.\u003c\/li\u003e\n  \u003cli\u003eRotor axial position and thrust deflection monitoring.\u003c\/li\u003e\n  \u003cli\u003eRod-drop style displacement measurements on industrial compressors.\u003c\/li\u003e\n  \u003cli\u003eHarsh chemical, oil-splash, and abrasive physical environments requiring high physical cable integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Element\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330854\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 25 mm Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e080\u003c\/td\u003e\n      \u003ctd\u003e8.0 metres (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Armor and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25\u003c\/td\u003e\n      \u003ctd\u003eArmored High Temperature FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx, NEPSI)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330854-080-25-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial, perfluoroalkoxyethylene (PFA) insulated FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Armor Material\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 stainless steel (SST) with PFA outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCharacteristic Impedance\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Capacitance\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCore Resistance (RCORE)\u003c\/td\u003e\n      \u003ctd\u003e2.0 Ohm +\/- 0.5 Ohm (for 8.0 m length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Jacket Resistance (RJACKET)\u003c\/td\u003e\n      \u003ctd\u003e0.6 Ohm +\/- 0.2 Ohm (for 8.0 m length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-35 degC to +200 degC (-31 degF to +392 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity Tolerance\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass and gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Tensile Strength\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 pounds) maximum rated pull at probe-to-cable joint\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Connection Torque\u003c\/td\u003e\n      \u003ctd\u003eFinger tight (0.565 N-m or 5 in-lb maximum torque)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Weight Density\u003c\/td\u003e\n      \u003ctd\u003e140 g\/m (1.5 oz\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe cable incorporates industrial ClickLoc coaxial terminations designed to lock and prevent signal loss under vibration:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Point\u003c\/th\u003e\n      \u003cth\u003eConnector Gender\/Type\u003c\/th\u003e\n      \u003cth\u003ePrimary Composition\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Connection Side\u003c\/td\u003e\n      \u003ctd\u003eMiniature Female Coaxial ClickLoc Connector\u003c\/td\u003e\n      \u003ctd\u003eBeryllium copper body, gold plated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProximitor Connection Side\u003c\/td\u003e\n      \u003ctd\u003eMiniature Male Coaxial ClickLoc Connector\u003c\/td\u003e\n      \u003ctd\u003eBrass body, gold plated\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure that the 330854 extension cable length combined with the 330851 probe length precisely matches the calibrated system length configured on the 330850 Proximitor Sensor (e.g. 1.0 m probe plus 8.0 m extension cable for a 9.0 m system).\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum bend radius of 25.4 mm (1.0 in) along the entire route, especially where the cable transitions out of protective conduit or junctions.\u003c\/li\u003e\n  \u003cli\u003eApply a Bently Nevada connector protector kit over ClickLoc connections located in areas of high moisture, humidity, oil mist, or ambient steam to prevent junction degradation.\u003c\/li\u003e\n  \u003cli\u003eSecure the armored cable within appropriate conduit or trays to prevent damage from adjacent machinery movement or heavy impact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 05 Multiple Approvals package covers hazardous area locations worldwide.\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: Intrinsically Safe Ex ia IIC T4\/T5 Ga; Non-sparking Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc.\u003c\/li\u003e\n  \u003cli\u003eCSA\/CNRTLUS: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III (Divisions 1 \u0026amp; 2).\u003c\/li\u003e\n  \u003cli\u003eCE Mark: Complies with relevant EU directives for industrial electromagnetic immunity.\u003c\/li\u003e\n  \u003cli\u003eRoHS: Fully compliant with directive standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666571129195,"sku":"330854-080-25-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330854-080-25-05-extension-cable-nueckml1tks_0ebd98c9-cdcd-4af2-a03a-81e80570f89f.jpg?v=1765440841"},{"product_id":"bently-nevada-330877-80-37-00-3300-xl-50-mm-extension-cable","title":"Bently Nevada 330877-80-37-00 3300 XL 50 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330877-80-37-00\u003c\/strong\u003e specifies a 3300 XL 50 mm extension cable configured with an 8.0 meter cable length, armored mechanical protection, and no agency approvals. This cable pairs with a 1.0 meter 3300 XL 50 mm proximity probe to establish a complete 9.0 meter transducer system with a compatible 3300 XL 50 mm Proximitor sensor. It is designed to transmit high-frequency eddy-current signals from the probe tip back to the sensor in demanding industrial rotating machinery environments.\u003c\/p\u003e\n\n\u003cp\u003eThis configuration incorporates Option 37, which wraps the perfluoroalkoxyethylene (PFA) insulated FluidLoc triaxial cable in a flexible stainless steel armor jacket. This design provides high mechanical resistance to abrasion and routing wear, contrasting with the unarmored Option 36. Additionally, because this unit carries Option 00 (No Approvals), it is specified for non-hazardous general industrial monitoring environments where certified explosion-proof or intrinsically safe ratings are not required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8.0 meter cable length (Option 80) for a total 9.0 meter system configuration when matched with a 1.0 meter probe.\u003c\/li\u003e\n  \u003cli\u003eFlexible stainless steel armor with protective PFA outer jacket (Option 37) to prevent physical cable damage.\u003c\/li\u003e\n  \u003cli\u003eFluidLoc coaxial cable structure with PFA insulation to prevent liquid migration along the cable interior.\u003c\/li\u003e\n  \u003cli\u003eStandard miniature coaxial connectors featuring gold-plated brass and gold-plated beryllium copper contacts.\u003c\/li\u003e\n  \u003cli\u003eBroad environmental operational limits from -51 degC to +200 degC (-60 degF to +392 degF).\u003c\/li\u003e\n  \u003cli\u003eMinimum bend radius of 25.4 mm (1.0 inch) to support installation within restricted routing pathways.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on large turbine rotors.\u003c\/li\u003e\n  \u003cli\u003eRotating machinery monitoring systems requiring very large target eddy-current displacement.\u003c\/li\u003e\n  \u003cli\u003eIndustrial steam turbine environments requiring resistance to high-temperature moisture ingress.\u003c\/li\u003e\n  \u003cli\u003eGeneral-purpose, non-hazardous area rotating machinery protection loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330877-80-37-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Extension Cable, Armored\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length\u003c\/td\u003e\n      \u003ctd\u003e80\u003c\/td\u003e\n      \u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Armor and Cable\u003c\/td\u003e\n      \u003ctd\u003e37\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc extension cable with stainless steel armor and PFA outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330877-80-37-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, PFA-insulated FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMechanical Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFlexible stainless steel armor with PFA outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Outer Diameter (Armored)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.65 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Armored Ferrule Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10.12 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFluidLoc Coaxial Cable Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature male and female coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass and gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +200 degC (-60 degF to +392 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance (Center to Coaxial)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 +\/- 0.5 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance (Coaxial to Coaxial)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.6 +\/- 0.2 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Connector to Cable)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 pounds) maximum rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (Option 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eLocation\u003c\/th\u003e\n      \u003cth\u003eContact Material\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMiniature Male Coaxial Connector\u003c\/td\u003e\n      \u003ctd\u003eProbe Connection Side\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass \/ Gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMiniature Female Coaxial Connector\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor Connection Side\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass \/ Gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure that the combined probe length and extension cable length equals the total system length designated by the Proximitor sensor (e.g., 1.0 m probe + 8.0 m extension cable = 9.0 m system).\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the minimum bend radius of 25.4 mm (1.0 inch) when routing the armored cable.\u003c\/li\u003e\n  \u003cli\u003eUse the supplied connector protectors to keep the ClickLoc junctions free of moisture and contaminants.\u003c\/li\u003e\n  \u003cli\u003eAvoid routing cables over sharp mechanical edges or in areas subject to continuous severe impacts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666571850091,"sku":"330877-80-37-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330877-80-37-00-3300-xl-50-mm-extension-cable-ufvygtavtst_b38e033e-43ef-4700-b5ac-a956c200f1f1.jpg?v=1765440855"},{"product_id":"bently-nevada-16710-13-interconnect-cable","title":"Bently Nevada 16710-13 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e16710-13\u003c\/strong\u003e is a high-quality interconnect cable designed for use with Bently Nevada acceleration transducers, specifically the 330400 and 330425 series. This cable configuration provides a 13.0 ft (3.96 m) length to facilitate reliable signal transmission in critical machinery monitoring applications, such as gear mesh monitoring and casing vibration analysis.\u003c\/p\u003e\n\u003cp\u003eThis cable features a 3-conductor shielded 22 AWG (0.5 mm2) construction, ensuring signal integrity in industrial environments. One end is terminated with a 3-socket plug for mating with the transducer, while the other end is fitted with terminal lugs for easy connection to monitoring instrumentation or terminal blocks. Proper installation using this shielded cable helps minimize false signals and maintains the frequency response characteristics of the connected accelerometer.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e13.0 ft (3.96 m) cable length\u003c\/li\u003e\n\u003cli\u003e3-conductor shielded 22 AWG (0.5 mm2) wire\u003c\/li\u003e\n\u003cli\u003e3-socket plug connector for 330400\/330425 series transducers\u003c\/li\u003e\n\u003cli\u003eTerminal lug termination at the monitoring end\u003c\/li\u003e\n\u003cli\u003eDesigned for critical machinery acceleration measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCasing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eGear mesh monitoring\u003c\/li\u003e\n\u003cli\u003eRotating machinery protection\u003c\/li\u003e\n\u003cli\u003eIndustrial acceleration transducer integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e16710-13\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable, 3-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e13.0 ft (3.96 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e16710-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3-conductor shielded 22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector (Sensor End)\u003c\/td\u003e\n\u003ctd\u003e3-socket plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector (Termination End)\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e13.0 ft (3.96 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e330400 and 330425 Accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Length\u003c\/td\u003e\n\u003ctd\u003e99 ft (30 m) (Standard capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the cable is routed away from high-voltage lines to prevent electromagnetic interference. When installing the 3-socket plug onto the accelerometer, ensure the mating part provides at least IP54 ingress protection if exposed to industrial environments. Use appropriate cable clamps to relieve strain on the connector. For hazardous area installations, adhere to the local electrical codes and ensure the system is installed according to the Bently Nevada control drawings relevant to the 330400 series.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666574569835,"sku":"16710-13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-13-interconnect-cable-3afmkd0ia3u_115e8947-ebaa-437b-9106-26490fe7b3f0.jpg?v=1765440892"},{"product_id":"bently-nevada-330930-065-03-00-3300-nsv-extension-cable","title":"Bently Nevada 330930-065-03-00 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 065 (6.5 meters cable length) and Option 03 (unarmored cable with connector protector) specify this 3300 NSv extension cable configuration — \u003cstrong\u003e330930-065-03-00\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUsed within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e, this 75 ohm coaxial cable provides the electrical connection between a 3300 NSv proximity probe and a 330980 Proximitor Sensor. The total system length (probe plus extension cable) must match the Proximitor Sensor's designed length configuration (such as 7.0 meters total when combined with a 0.5 meter probe). This specific unarmored version features a pre-installed fluorosilicone connector protector to guard the probe-to-cable junction against fluid ingress and particulate contamination in tight machinery clearances.\u003c\/p\u003e\n\u003cp\u003eCompared to alternative armored variations, this unarmored configuration offers a smaller installation profile, ideal for routing through tight conduit runs or internal machine cavities. Because this SKU is ordered under Option 00 for agency approvals, it is selected for non-hazardous locations or applications where specialized regional certifications are not required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e6.5-meter cable length (21.3 feet) for specific spatial configuration needs\u003c\/li\u003e\n  \u003cli\u003eUnarmored design providing maximum routing flexibility with a 25.4 mm (1.0 in) minimum bend radius\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc connectors ensuring positive engagement and resistance to vibration loosening\u003c\/li\u003e\n  \u003cli\u003eFluorosilicone connector protector pre-installed on the female end to prevent fluid contamination at the connector interface\u003c\/li\u003e\n  \u003cli\u003eHigh-grade FEP jacket offering chemical resistance inside industrial machinery environments\u003c\/li\u003e\n  \u003cli\u003eLow electrical capacitance of 69.9 pF\/meter to maintain signal integrity over the measurement chain\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position measurements in small-bore rotating machinery\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbine vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressors with limited target geometry and restricted installation clearances\u003c\/li\u003e\n  \u003cli\u003eHigh-speed machinery requiring non-contact eddy current transducer systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-065-03-00\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable, 75 ohm coaxial\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e065\u003c\/td\u003e\n      \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eWithout stainless steel armor, with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot Required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-065-03-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Core Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.80 mm (0.11 in) maximum outer diameter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (Unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePre-installed fluorosilicone connector protector (female end)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Materials\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.220 ohm\/meter (0.067 ohm\/foot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShield Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.066 ohm\/meter (0.020 ohm\/foot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/meter (21.3 pF\/foot) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector-to-Connector Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRecommended: Finger tight; Maximum: 0.56 N-m (5 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 degC (-62 to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected (tested to IEC 68-2-3 damp heat)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNot required (Option 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Length Match:\u003c\/strong\u003e Ensure that the sum of the extension cable length (6.5 m) and the probe length (e.g., 0.5 m) equals the Proximitor Sensor total length calibration (7.0 m).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Tightening:\u003c\/strong\u003e Connect finger-tight. The maximum allowable connector torque is 0.56 N-m (5 in-lb) to prevent damage to the miniature coaxial threads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius Limits:\u003c\/strong\u003e Maintain a bend radius of at least 25.4 mm (1.0 in) along all sections of the FEP jacket to prevent shielding degradation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Insulation:\u003c\/strong\u003e Avoid routing connectors through conductive fluids or exposing them to high-pressure washdowns without additional protective sleeving or silicone self-fusing tape.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666574930283,"sku":"330930-065-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-065-03-00-sensor-proximity-probe-cable-5wuiqxry51d_556e163e-e354-44cf-b2fc-0c24eecd7698.jpg?v=1765440898"},{"product_id":"bently-nevada-330130-030-00-00-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-030-00-00 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330130-030-00-00\u003c\/strong\u003e is a 3.0 meter standard extension cable designed for use in 3300 XL 8 mm proximity transducer systems. This component serves as the vital link between the 3300 XL 8 mm proximity probe and the 3300 XL Proximitor sensor, ensuring the transmission of eddy-current displacement signals for critical machinery monitoring applications. The configuration consists of a standard coaxial cable (Option 00) with a total length of 3.0 meters (Option 030) and does not require special agency approvals (Option 00).\u003c\/p\u003e\n\n\u003cp\u003eThe extension cable features Bently Nevada’s proprietary ClickLoc connectors, which provide reliable mechanical and electrical connection security. When installing this cable, verify that the total length of the extension cable plus the probe length matches the system requirements of the associated Proximitor sensor. Proper installation and connection are essential for maintaining the accurate shaft vibration and axial position measurements required for protection of turbines, compressors, and other rotating equipment.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3.0 meter (9.8 feet) cable length provides flexibility for standard installation distances in machinery monitoring.\u003c\/li\u003e\n\u003cli\u003eStandard cable configuration (Option 00) for general-purpose environments without specialized armor or fluid-resistant requirements.\u003c\/li\u003e\n\u003cli\u003eEquipped with miniature coaxial ClickLoc connectors for secure, reliable signal integrity.\u003c\/li\u003e\n\u003cli\u003eFully compatible with 3300 XL 8 mm proximity probes and 3300 XL Proximitor sensors.\u003c\/li\u003e\n\u003cli\u003eDesigned for consistent signal transmission in 3300 XL monitoring chains.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine and compressor shaft vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eAxial position and rotor displacement measurements.\u003c\/li\u003e\n\u003cli\u003eCritical rotating machinery protection in power generation, oil and gas, and petrochemical industries.\u003c\/li\u003e\n\u003cli\u003eIntegration into existing 3300 XL 8 mm eddy-current transducer systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330130-030-00-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length\u003c\/td\u003e\n\u003ctd\u003e030\u003c\/td\u003e\n\u003ctd\u003e3.0 meters (9.8 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Cable Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330130-030-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 meters (9.8 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure all connections are clean and fully seated using the ClickLoc connector mechanism to prevent signal loss or interference. The cable should be routed away from high-voltage lines or sources of electromagnetic interference to maintain measurement accuracy. Do not exceed the minimum bend radius of the cable during installation. For hazardous area applications, ensure that the chosen cable and system components meet local certification requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666607763819,"sku":"330130-030-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-030-00-00-3300-xl-standard-extension-cable-pw2p4idd0hd_adb4bc18-f201-445d-8af3-0dabf5d37b92.jpg?v=1765444097"},{"product_id":"bently-nevada-16710-26-interconnect-cable","title":"Bently Nevada 16710-26 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e16710-26\u003c\/strong\u003e is a 26-foot (7.9 m) interconnect cable designed for critical machinery monitoring systems, including Bently Nevada 3300 and 7200 series proximity transducer chains. This high-quality coaxial cable serves as the primary signal path between the Proximitor sensor and the monitoring instrumentation, maintaining signal integrity in demanding industrial environments.\n\nThis cable is configured with a standard 26-foot length (Option 26) and features robust shielding to minimize electromagnetic interference. It is essential for transmitting accurate vibration and position data from the probe to the monitor, supporting the reliable operation of rotating machinery protection systems.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e26-foot (7.9 m) standard length for flexible installation\u003c\/li\u003e\n\u003cli\u003e75 Ohm characteristic impedance optimized for Bently Nevada proximity transducer systems\u003c\/li\u003e\n\u003cli\u003eShielded construction to reduce signal noise and electromagnetic interference\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Bently Nevada Proximitor sensors and monitoring modules\u003c\/li\u003e\n\u003cli\u003eRugged outer jacket suitable for industrial machinery environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft vibration and axial position measurement\u003c\/li\u003e\n\u003cli\u003eRotating machinery protection (turbines, compressors, pumps, motors)\u003c\/li\u003e\n\u003cli\u003eSignal transmission in 3300 and 7200 proximity transducer systems\u003c\/li\u003e\n\u003cli\u003eCritical machinery monitoring in oil and gas, power generation, and petrochemical facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e16710-26\u003c\/td\u003e\n\u003ctd\u003eInterconnect Cable, 26 ft (7.9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e26 feet (7.9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e16710-26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eCoaxial Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e26 ft (7.9 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacteristic Impedance\u003c\/td\u003e\n\u003ctd\u003e75 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to +121 degC (-67 degF to +250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity Transducer Systems (3300\/7200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the cable is routed away from high-voltage power lines to prevent induced noise on the signal path.\u003c\/li\u003e\n\u003cli\u003eUse appropriate cable conduits or trays where mechanical protection is required to avoid abrasion or impact damage.\u003c\/li\u003e\n\u003cli\u003eEnsure connectors are tightened to the specified torque to maintain a secure electrical connection.\u003c\/li\u003e\n\u003cli\u003eMinimize sharp bends during installation to maintain the coaxial geometry and shielding integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666608943467,"sku":"16710-26","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-26-interconnect-cable-lktr0yronp0_e524e49b-e89b-4911-9f74-2ddd86e090c8.jpg?v=1765444113"}],"url":"https:\/\/www.plcprotech.com\/collections\/cables.oembed?page=53","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}