{"title":"Danfoss MBS 3300\/3350 Pressure Transmitter","description":"\u003cp\u003eThis collection features the Danfoss MBS 3300 and MBS 3350 compact pressure transmitters, designed for industrial and marine applications. Both series utilize an acid-resistant stainless steel enclosure (AISI 316L) and provide a standard 4-20 mA output signal. While the MBS 3300 is engineered for reliable pressure measurement in severe environments, the MBS 3350 includes an integrated pulse snifter to protect against cavitation, liquid hammer, and pressure peaks. All models are temperature-compensated and meet major maritime certification standards.\u003c\/p\u003e","products":[{"product_id":"danfoss-060g6763-mbs-3000-pressure-transmitter","title":"Danfoss 060G6763 MBS 3000 Pressure Transmitter","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 060G6763\u003c\/strong\u003e is a high-performance \u003cstrong\u003eMBS 3000 pressure transmitter\u003c\/strong\u003e designed for use in harsh industrial environments. This compact \u003cstrong\u003epressure transmitter\u003c\/strong\u003e is engineered to provide reliable and accurate pressure measurement for a wide range of applications, including hydraulic systems, pump control, and process monitoring. The device features a rugged design, ensuring long-term stability and resistance to shock and vibration.\u003c\/p\u003e\n\u003cp\u003eOperating with a standard industrial current output signal (4–20 mA), the \u003cstrong\u003e060G6763\u003c\/strong\u003e integrates seamlessly into PLC and DCS control systems. It is built to withstand demanding ambient conditions, with an operating temperature range of -40 Celsius to 85 Celsius and an IP65-rated enclosure, providing robust protection against dust and water jets.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRobust design for industrial pressure measurement\u003c\/li\u003e\n\u003cli\u003eMeasuring range: -1 to 15 bar (-14.5 to 217.5 psi)\u003c\/li\u003e\n\u003cli\u003eReliable 4-20 mA current output signal\u003c\/li\u003e\n\u003cli\u003eWide supply voltage range: 9.00 V DC to 32.00 V DC\u003c\/li\u003e\n\u003cli\u003eIP65 ingress protection rating\u003c\/li\u003e\n\u003cli\u003eCompact form factor with EN 175301-803-A angular electrical connection\u003c\/li\u003e\n\u003cli\u003eHigh resistance to shock and vibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraulic and pneumatic systems\u003c\/li\u003e\n\u003cli\u003eCompressor and pump monitoring\u003c\/li\u003e\n\u003cli\u003eProcess plant automation\u003c\/li\u003e\n\u003cli\u003eHVAC and cooling systems\u003c\/li\u003e\n\u003cli\u003eGeneral industrial machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e060G6763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMBS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e-1 to 15 bar (-14.5 to 217.5 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e9.00 to 32.00 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eAngular connector (EN 175301-803-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.125 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eConnections\/Interfaces\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 1\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 2\u003c\/td\u003e\n\u003ctd\u003eOutput Signal (4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround\u003c\/td\u003e\n\u003ctd\u003eCase\/Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the \u003cstrong\u003etransmitter\u003c\/strong\u003e in a location that minimizes liquid hammer and pressure surges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e For liquid applications, mount the sensor with the pressure connection facing downward to prevent air entrapment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cable for the 4-20 mA loop to mitigate electromagnetic interference (EMI). Ensure the EN 175301-803-A connector is fully tightened to maintain the IP65 seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Ensure the supply voltage remains within the 9.00–32.00 V DC range to avoid signal inaccuracies or damage to the internal electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Avoid mounting the device in locations exceeding the maximum ambient temperature of 85 Celsius.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102306787691,"sku":"060G6763","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g6763-pevtbcgev2j.png?v=1776136948"},{"product_id":"danfoss-060g3830-mbs-3000-1615-1-pressure-transmitter","title":"Danfoss 060G3830 MBS 3000-1615-1 Pressure Transmitter","description":"\u003cp\u003eThe \u003cstrong\u003e060G3830\u003c\/strong\u003e is a high-performance \u003cstrong\u003eMBS 3000-1615-1 Pressure Transmitter\u003c\/strong\u003e manufactured by Danfoss, designed for heavy-duty industrial applications. This compact pressure transmitter provides reliable measurement in environments with high mechanical loads, such as cavitation, liquid hammer, or pressure peaks. The unit is optimized for a pressure range of 0 to 4 bar using a relative gauge pressure reference and provides a 0-10 V output signal for precise integration into automation and control systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRobust design resistant to harsh environmental conditions\u003c\/li\u003e\n\u003cli\u003eHigh vibration stability and EMC protection\u003c\/li\u003e\n\u003cli\u003eGauge (relative) pressure measurement from 0 to 4 bar\u003c\/li\u003e\n\u003cli\u003eStandardized 0-10 V analog output signal\u003c\/li\u003e\n\u003cli\u003eCompact construction with plug connection (EN 175301-803)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHydraulic systems\u003c\/li\u003e\n\u003cli\u003eCompressor and pump monitoring\u003c\/li\u003e\n\u003cli\u003eHVAC and water treatment systems\u003c\/li\u003e\n\u003cli\u003eIndustrial process control\u003c\/li\u003e\n\u003cli\u003eMobile hydraulics and machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e060G3830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMBS 3000-1615-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e0 - 4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Reference\u003c\/td\u003e\n\u003ctd\u003eGauge (relative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0 - 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003ePlug Pg 9 (EN 175301-803)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the transmitter in a position that minimizes exposure to extreme pressure spikes. Ensure the process connection is tightened to the correct torque to prevent leaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the 0-10 V output to the corresponding analog input of your PLC or control device. Ensure proper shielding of the cable to prevent signal noise from nearby power lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Although the unit is designed for industrial use, protect the electrical connection (EN 175301-803 plug) from direct water spray or corrosive chemicals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Proper grounding of the transmitter housing is recommended to ensure optimal EMC performance and signal stability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102313013611,"sku":"060G3830","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g3830-0rpv3i04vyn.png?v=1776136941"},{"product_id":"mbs-3000-060g1106-danfoss-compact-pressure-transmitter","title":"MBS 3000 (060G1106) Danfoss Compact Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMBS 3000 (060G1106)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, heavy-duty pressure transmitter designed for use in almost all industrial applications, even under severe environmental conditions. As a cornerstone of the Danfoss industrial sensor portfolio, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDanfoss 060G1106 (060G1106)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a reliable 4–20 mA output signal proportional to the measured pressure. This model is specifically calibrated for a 0–60 bar gauge pressure range, making it an ideal choice for B2B applications in hydraulic systems, air compressors, and water treatment plants where precision, vibration stability, and electromagnetic compatibility (EMC) are essential requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe MBS 3000-2811-1AB04 is engineered for long-term stability. It features a piezo-resistive silicon sensing element housed in a high-grade acid-resistant stainless steel enclosure (AISI 316L). The electrical interface is a standardized Plug Pg 9 (EN175301-803-A), ensuring easy installation and maintenance. The pressure connection is a G ¼ A thread according to EN 837 standards. To handle the rigors of industrial environments, the transmitter is highly resistant to cavitation, liquid hammer, and pressure peaks, ensuring a long service life even in systems with fluctuating hydraulic loads.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000 (060G1106)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 60 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA (2-wire)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 - 32 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803-A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG ¼ A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy (Typ.)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 0.5% FS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to 85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (AISI 316L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does \"Gauge (Relative)\" pressure reference mean for the 060G1106?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGauge pressure means the transmitter measures the pressure relative to the current atmospheric pressure. The sensor will output 4 mA when the system is open to the atmosphere and 20 mA when the system pressure reaches 60 bar above atmospheric levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transmitter handle high-vibration environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MBS 3000 series is specifically designed for industrial machinery. It is tested for vibration stability according to IEC 60068-2-6 and shock resistance according to IEC 60068-2-27, making it suitable for mounting directly on pumps and engines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the output signal protected against wiring errors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter includes polarity protection, meaning it will not be damaged if the positive and negative wires of the 4–20 mA loop are accidentally reversed during installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring for 4-20 mA Loop:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe MBS 3000 uses a 2-wire configuration. Connect the positive supply to Pin 1 and the return signal to Pin 2 of the Pg 9 plug. Ensure the total loop resistance does not exceed the limit determined by your supply voltage (\u003cspan class=\"math-inline\"\u003e$R_{loop} \\leq (V_{supply} - 9V) \/ 0.02A$\u003c\/span\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Port Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the G ¼ A connection, use a suitable bonded seal (Dowty washer) or copper gasket to ensure a leak-proof interface. Avoid using PTFE tape on parallel threads as it can lead to improper seating or debris entering the sensing orifice.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the IP65 rating of the electrical connection, ensure the Pg 9 plug's gasket is correctly seated and the central screw is tightened. For outdoor installations, it is a best practice to point the cable entry downwards to prevent water from pooling at the connector interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102377566571,"sku":"060G1106","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1106-hizko0a4nz3.png?v=1776136907"},{"product_id":"mbs-3000-060g1121-danfoss-low-pressure-transmitter","title":"MBS 3000 060G1121 Danfoss Low Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1121 (060G1121)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision-engineered low-pressure transmitter within the high-performance Danfoss MBS 3000 series. Designed for high-accuracy measurement in ranges from 0 - 1 bar, this sensor is a staple in HVAC systems, tank level monitoring, and low-pressure pneumatic circuits. By converting gauge pressure into a stable 4 - 20 mA analog output, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1121\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for granular control over sensitive industrial processes. Its robust stainless steel housing and excellent vibration stability make it a reliable choice for demanding environments such as power plants and chemical processing facilities, where maintaining specific pressure thresholds is critical to preventing system failures and ensuring operational safety.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 060G1121 model code identifies the following technical configurations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e060G\u003c\/strong\u003e: Commercial prefix for the Danfoss industrial sensor portfolio.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Indicates the specific low-pressure measuring range of 0 to 1 bar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Specifies Gauge (relative) pressure reference, measuring against ambient atmosphere.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Industry-standard 4 - 20 mA output signal for long-distance transmission with low noise interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Electrical connection via a Plug Pg 9 (EN 175301-803-A), providing a secure and replaceable interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAB04\u003c\/strong\u003e: Mechanical connection utilizing the G 1\/4 A (EN 837) thread standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e060G1121\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark \/ EU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 1 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Reference\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5 percent FS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (AISI 316L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 060G1121 be used for vacuum measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1121\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis calibrated for 0 - 1 bar gauge pressure. While it can physically withstand a vacuum, it is not designed to provide accurate linear output for negative pressure values. For vacuum applications, a dedicated vacuum or compound range transmitter should be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this model suitable for media temperatures exceeding 85 deg C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard operating limit is 85 deg C. If your process media exceeds this, it is highly recommended to use a syphon tube or a long capillary to dissipate heat before the media reaches the sensor diaphragm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the power supply polarity is accidentally reversed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 060G1121 includes integrated reverse polarity protection. This prevents damage to the internal electronics if the loop wiring is incorrectly connected during commissioning.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Pressure Accuracy \u0026amp; Venting:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1121\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a gauge pressure transmitter in a low-pressure range (1 bar), accuracy is highly dependent on proper atmospheric venting. Ensure that the Pg 9 plug and the cable used do not completely hermetically seal the reference port. The internal venting mechanism must be able to \"breathe\" to account for changes in local barometric pressure, which could otherwise cause a zero-point shift in such a sensitive range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Shielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor optimal performance, use a shielded cable for the 2-wire 4 - 20 mA loop. In 0 - 1 bar applications, even minor electromagnetic interference (EMI) can represent a significant percentage of the total measured range. Connect the shield to the ground terminal of the PLC or DCS, ensuring it is not grounded at the sensor end to avoid potential ground loop currents that could distort the pressure reading.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102381826411,"sku":"060G1121","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1121-j0gsqladyc0.png?v=1776136911"},{"product_id":"danfoss-060g3203-mbs-3300-flush-diaphragm-pressure-transmitter","title":"Danfoss 060G3203 MBS 3300 Flush Diaphragm Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 060G3203\u003c\/strong\u003e is a high-precision pressure transmitter from the MBS 3300 series, specifically designed for applications where hygienic or viscous media monitoring is required. Featuring a \u003cstrong\u003eflush diaphragm\u003c\/strong\u003e design, this transmitter eliminates the dead zones typically found in standard pressure ports, making it ideal for food and beverage processing, pharmaceutical manufacturing, or any process involving media that could clog a traditional recessed sensor. Built with an ATEX-approved, rugged construction, it ensures reliable performance and safety in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 060G3203 is engineered to provide stable, repeatable measurements while resisting media buildup and clogging.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlush Diaphragm:\u003c\/strong\u003e The sensing element is mounted flush with the process connection, ensuring that the media flows directly across the diaphragm without creating pockets where residue or bacteria could accumulate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e It provides an industry-standard 4 - 20 mA output signal. With factory-set clipping levels (3.6 mA low \/ 22.4 mA high), the transmitter allows control systems to immediately detect open-circuit or short-circuit faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e Housed in an IP65-rated enclosure with a DIN-plug (EN 175301-803-A) electrical connection, the unit is protected against dust and low-pressure water jets, ensuring longevity in washdown environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e060G3203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e0 - 4 bar (0 - 58 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4 - 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Typ.)\u003c\/td\u003e\n\u003ctd\u003e0.3 % FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eG 1\/2 A (Flush Diaphragm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overload\u003c\/td\u003e\n\u003ctd\u003e8 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.246 kg (Net)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is a \"flush diaphragm\" necessary for my application?\u003c\/strong\u003e A flush diaphragm is critical in applications involving viscous fluids (like syrups, pastes, or slurries) or hygienic processes. Because the diaphragm is exposed directly to the main flow, it prevents the sensing port from clogging, which would otherwise lead to \"ghost\" readings or sensor failure in standard transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transmitter be used in hazardous areas?\u003c\/strong\u003e The unit carries \u003cstrong\u003eATEX approval\u003c\/strong\u003e, which pertains to its safety characteristics in potentially explosive atmospheres. However, you must verify that the specific hazardous zone classification matches the ATEX rating of the device before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the transmitter require periodic calibration?\u003c\/strong\u003e No, the 060G3203 does not support field adjustment of zero or span. It is factory-calibrated to ensure long-term stability. If the device falls out of its accuracy specification over many years of use, it should be replaced or returned to the factory for recalibration.\u003c\/p\u003e\n\u003ch3\u003eEngineering Guidelines and Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Torque:\u003c\/strong\u003e The 27 mm hexagonal nut is designed for tightening. Use a proper wrench and ensure the hygienic or standard sealing gasket is seated correctly to avoid leaks or pressure-induced measurement errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia Temperature:\u003c\/strong\u003e While the ambient rating is up to 85°C, the compensated temperature range is 0 - 80°C. For processes exceeding these temperatures, consider using a cooling extension or a \"pigtail\" siphon to protect the transmitter's internal electronics from excessive heat conduction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaning Protocols:\u003c\/strong\u003e In hygienic applications, ensure that your CIP (Clean-in-Place) or SIP (Sterilize-in-Place) chemicals are compatible with the stainless steel diaphragm material (typically 316L) to prevent surface pitting.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102381924715,"sku":"060G3203","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g3203-oybmd1xpupe.png?v=1776136939"},{"product_id":"danfoss-060g1626-mbs-3000-pressure-transmitter","title":"Danfoss 060G1626 MBS 3000 Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 060G1626 (MBS 33-1015-1AB08)\u003c\/strong\u003e is a high-accuracy pressure transmitter designed for demanding industrial applications where precise pressure regulation is required. This unit provides a 0 - 10 V analog output, making it highly compatible with modern PLC, DCS, and building automation controllers. Its robust, compact design ensures reliable performance in harsh environments, including water treatment, HVAC systems, and industrial hydraulics, where it serves as a critical feedback element to prevent over-pressure conditions and optimize system efficiency.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e060G1626\u003c\/strong\u003e is part of the MBS 3000 series, which utilizes a specialized piezoresistive sensing element to deliver consistent measurement accuracy over a long service life.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Technology:\u003c\/strong\u003e The transmitter features an integrated circuit that compensates for temperature fluctuations, ensuring linear and stable signal output across the specified measuring range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Interface:\u003c\/strong\u003e Equipped with a G 1\/2 A (EN 837) pressure connection, this transmitter is designed for standard industrial piping and manifold installations, ensuring a leak-proof seal under rated operating pressures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Interface:\u003c\/strong\u003e The device utilizes a standard Pg 9 (EN175301-803) plug connection, which simplifies field wiring while maintaining an excellent ingress protection rating for the electrical contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Range:\u003c\/strong\u003e Calibrated for a 0 - 1 bar gauge pressure range, this unit is ideal for low-pressure monitoring and vacuum applications where high sensitivity is mandatory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMBS 33-1015-1AB08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct No.\u003c\/td\u003e\n\u003ctd\u003e060G1626\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0 - 1 bar (Gauge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0 - 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Conn.\u003c\/td\u003e\n\u003ctd\u003ePlug Pg 9 (EN175301-803)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Conn.\u003c\/td\u003e\n\u003ctd\u003eG 1\/2 A (EN 837)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 0 - 10 V signal susceptible to electromagnetic interference over long cable runs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, voltage signals (0 - 10 V) can be influenced by electrical noise in long cable runs, especially near variable frequency drives or high-voltage lines. To minimize this, use shielded, twisted-pair cables and ensure the shield is grounded at the controller side.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"Gauge (relative)\" pressure reference mean?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA gauge pressure reference means the transmitter measures pressure relative to the current atmospheric pressure. This is the standard for most industrial process monitoring, where the sensor reading reflects the pressure difference between the system media and the surrounding air.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transmitter be mounted in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MBS 3000 is largely position-independent. However, for liquid media, it is best practice to mount the transmitter with the pressure port facing downward or sideways to prevent the accumulation of air bubbles or debris against the sensing element.\u003c\/p\u003e\n\u003ch3\u003eEngineering Guidelines and Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping Connections:\u003c\/strong\u003e Use appropriate sealing tape or washers compatible with the media being measured to ensure a seal at the G 1\/2 A connection. Do not over-torque the transmitter housing during installation; use the hexagonal flats on the body to apply force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Requirements:\u003c\/strong\u003e To ensure accurate readings, keep the signal cable separate from power lines. Terminate the cable shield to a clean ground plane at the control panel input to maximize the signal-to-noise ratio.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-pressure Protection:\u003c\/strong\u003e Although the MBS 3000 is built for durability, ensure that the system pressure does not exceed the maximum burst pressure rating of the sensor during system testing or pump startup events.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102408499563,"sku":"060G1626","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1626-i2ei3ef2lcs.png?v=1776136919"},{"product_id":"danfoss-060g6538-mbs-3000-pressure-transmitter","title":"Danfoss 060G6538 MBS 3000 Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 060G6538 (MBS 3000)\u003c\/strong\u003e is a high-precision pressure transmitter designed for reliable monitoring in industrial and commercial fluid systems. Utilizing proven resistance sensor technology, this compact transmitter provides consistent, high-fidelity analog output for real-time pressure tracking. It is an essential component in protecting hydraulic circuits, monitoring compressor performance, and managing water processing infrastructure. The \u003cstrong\u003eMBS 3000\u003c\/strong\u003e series is engineered to thrive in demanding conditions, offering superior vibration resistance and electromagnetic compatibility, which effectively mitigates the risk of signal drift and system failure in continuous-duty applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e060G6538\u003c\/strong\u003e is built to meet the rigorous demands of industrial automation, focusing on durability and seamless integration into existing control frameworks.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Technology:\u003c\/strong\u003e The unit incorporates a robust resistance sensor design, delivering accurate and linear analog signals suitable for standard PLC or DCS interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Integrity:\u003c\/strong\u003e Featuring a standard amplifier configuration, the MBS 3000 ensures signal stability across varying temperature ranges, preventing measurement errors that can lead to inefficient process control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Durability:\u003c\/strong\u003e The housing is constructed to resist mechanical stress, making the transmitter suitable for high-vibration environments where less rugged units might experience mechanical fatigue or premature failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Compatibility:\u003c\/strong\u003e Its versatile interface allows for straightforward integration into hydraulic manifolds and standard process piping, serving as a reliable feedback loop for automated pressure regulation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMBS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e060G6538\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Theory\u003c\/td\u003e\n\u003ctd\u003eResistance Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eAnalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eConsumption \/ Pressure Sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg (Approx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the MBS 3000 compatible with corrosive industrial media?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MBS 3000 is designed for standard industrial fluids. For highly aggressive or corrosive chemicals, verify the wetted parts material compatibility against the Danfoss technical documentation. If your media is highly reactive, a diaphragm seal or alternative transmitter material may be required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transmitter be used in high-vibration applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MBS 3000 is specifically designed for high-vibration environments. However, ensure that the pressure connection is tightened to the specified torque and that the cable is properly supported to prevent fatigue at the electrical connector interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should the transmitter be calibrated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the MBS 3000 is characterized by high long-term stability, it is recommended to verify the zero point and span during annual maintenance cycles in critical process applications to ensure measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eEngineering Guidelines and Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Positioning:\u003c\/strong\u003e For liquid applications, mount the transmitter with the pressure connection pointing downward to prevent sediment accumulation. If monitoring steam or high-temperature gases, use a cooling coil or a capillary tube to ensure the transmitter operates within its specified temperature limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connections:\u003c\/strong\u003e Use shielded cables for the analog signal output to prevent interference from adjacent power lines or VFDs. Terminate the shield at the control panel ground to ensure optimal signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Startup:\u003c\/strong\u003e Before putting the system into full operation, slowly pressurize the line to prevent \"water hammer\" effects. Sudden pressure spikes can exceed the burst pressure rating of the sensor and lead to permanent damage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102408630635,"sku":"060G6538","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g6538-3mklleicklr.png?v=1776136947"},{"product_id":"danfoss-060g3214-pressure-transmitter-mbs-series","title":"Danfoss 060G3214 Pressure Transmitter MBS Series","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 060G3214 (060G3214)\u003c\/strong\u003e is a high-precision pressure transmitter designed for demanding industrial environments where accurate, stable pressure feedback is critical for process optimization. By delivering a linearized 4-20 mA output signal, this transmitter minimizes system latency and ensures precise control in applications such as HVAC systems, hydraulic power units, and general industrial process monitoring. Its robust, flush-diaphragm construction is specifically optimized to prevent clogging in media-heavy environments, significantly reducing maintenance frequency and preventing unplanned system downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis transmitter features an advanced sensing architecture that provides a typical accuracy of 0.3 percent of the full scale. The device is built for resilience, boasting an IP65-rated enclosure that ensures protection against moisture and particulates. The integration of a standard DIN-plug (EN 175301-803-A) facilitates rapid field integration and maintenance. Engineered for high-speed operation, the device maintains a rapid response time of less than 4 ms, making it ideal for monitoring transient pressure spikes in dynamic fluid power circuits. It is certified for ATEX-compliant environments, ensuring safe operation in designated hazardous areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e060G3214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eDenmark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.246 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e0 to 16 bar (0 to 232.06 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e9 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Typical)\u003c\/td\u003e\n\u003ctd\u003e0.3 % FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Connection\u003c\/td\u003e\n\u003ctd\u003e1\/2 inch (Flush Diaphragm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the flush diaphragm feature important for my application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe flush diaphragm design is specifically intended for viscous or particle-laden media. Unlike standard recessed diaphragms, it prevents dead zones where residue can accumulate, harden, and lead to signal drift or total blockage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this transmitter suitable for explosive atmospheres?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 060G3214 carries ATEX approval, allowing it to be utilized in specific hazardous zone installations. Always refer to the official datasheet for the exact zone classification and safety parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the low clipping level function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe low clipping level of 3.6 mA acts as a diagnostic threshold, signaling to the controller that the measured pressure is below the calibrated range or that a potential sensor fault exists, allowing for automated system safety shutdowns.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended cable specification for the DIN-plug connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe recommend using shielded, twisted-pair instrumentation cable to maintain signal integrity and prevent electromagnetic interference from nearby industrial drives or high-voltage lines.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlush Diaphragm Protection:\u003c\/strong\u003e During installation, exercise extreme caution to avoid damaging the exposed sensing diaphragm. Do not use sharp tools to clean the face. Ensure the process fitting is clean and the seal is properly seated to prevent leaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Grounding:\u003c\/strong\u003e To achieve maximum accuracy, ensure the transmitter housing is properly grounded to the system chassis. In high-noise environments, connect the cable shield to the ground at the control cabinet end only to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Specifications:\u003c\/strong\u003e Use a 27 mm wrench on the designated hexagonal section when tightening the pressure connection. Do not apply force to the transmitter housing during installation, as this can induce internal mechanical stress and compromise the calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e While the device is rated for ambient temperatures up to 85 deg C, avoid mounting the transmitter in direct proximity to high-heat sources (such as steam lines or furnace walls) to prevent long-term electronic degradation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102410137963,"sku":"060G3214","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g3214-hwmo215bfn3.png?v=1776136940"},{"product_id":"danfoss-060g6361-mbs-3000-pressure-transmitter","title":"Danfoss 060G6361 MBS 3000 Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 060G6361 (MBS 3000)\u003c\/strong\u003e is a high-performance, compact pressure transmitter designed for reliable fluid pressure monitoring in demanding industrial applications. The \u003cstrong\u003e060G6361 (MBS 3000)\u003c\/strong\u003e provides a standard 4-20 mA output signal, making it an ideal choice for integration into PLC and DCS control loops in sectors including hydraulic systems, HVAC, and industrial processing. Engineered for versatility, this transmitter handles a pressure range of -1 to 3 bar (-14.5 to 43.5 psi), ensuring consistent accuracy and long-term stability even in harsh environments with fluctuating thermal conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe MBS 3000 series is constructed with a focus on durability and signal integrity. It features an angular connector conforming to the EN 175301-803-A standard, allowing for secure, industry-standard electrical termination. The housing is rated at IP65, offering robust protection against dust ingress and low-pressure water spray, essential for maintaining reliability in exposed or humid industrial environments. With an operating temperature range spanning from -40 Celsius to 85 Celsius, this transmitter is built to withstand extreme thermal environments without performance degradation. The electronics are optimized for a supply voltage between 9 VDC and 32 VDC, providing flexibility for diverse automation power architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e060G6361 (MBS 3000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003ePressure Range\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e-1 to 3 bar (-14.5 to 43.5 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e4 - 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e9 - 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eEN 175301-803-A (Angular)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-40 to 85 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e0.157 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 060G6361 suitable for high-vibration applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MBS 3000 series is designed with a high degree of vibration stability. However, for installations subjected to extreme mechanical shock, utilizing flexible piping or damping mounts is advised.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter require external signal conditioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the device provides a standard, industry-ready 4-20 mA current output, which can be connected directly to the analog input cards of your controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the EN 175301-803-A connector impact installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe angular connector provides a space-saving footprint and allows for easy cable maintenance, ensuring that the connection remains secure and shielded from environmental hazards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit operate in vacuum conditions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith a lower pressure limit of -1 bar, the unit is fully capable of monitoring vacuum to positive pressure transitions within its rated range.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Integrity\u003c\/strong\u003e: Ensure the angular connector is seated correctly and the gasket is intact to maintain the IP65 seal. Tighten the central screw to the recommended torque to ensure electrical contact stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Although the unit is rated for operation up to 85 Celsius, install the transmitter away from direct heat radiation sources (such as steam pipes) to improve long-term calibration accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia Compatibility\u003c\/strong\u003e: Verify that the process medium is compatible with the stainless steel wetted parts of the MBS 3000. Avoid installing in systems where process pressure spikes (water hammer) exceed the transmitter's proof pressure limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102410334571,"sku":"060G6361","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g6361-mblddalg3hn.png?v=1776136949"},{"product_id":"danfoss-060g3711-mbs-3000-pressure-transmitter","title":"Danfoss 060G3711 MBS 3000 Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e060G3711 (MBS 3000)\u003c\/strong\u003e is a high-precision pressure transmitter engineered for demanding industrial environments where consistent, accurate fluid monitoring is essential. This versatile sensor covers a pressure range of 0 bar to 16 bar (0 psi to 232 psi), making it highly effective for applications such as hydraulic systems, refrigeration plants, and water treatment processes. By providing a stable 4 - 20 mA output signal, the \u003cstrong\u003e060G3711\u003c\/strong\u003e ensures reliable communication with PLC and DCS controllers, effectively reducing system response times and preventing unexpected process downtime. Its compact, all-stainless steel design allows for seamless integration into confined instrumentation panels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eMBS 3000\u003c\/strong\u003e series is constructed to withstand high-vibration and aggressive media conditions. The unit features a laser-welded stainless steel enclosure that ensures internal protection against contaminants, verified by an IP65 rating. The electrical termination follows the EN 175301-803-A standard using an angular connector, which facilitates quick installation and secure signal transmission. Designed for versatility, the transmitter functions across a broad supply voltage range of 9.00 - 32.00 VDC and remains operational in extreme temperature environments ranging from -40 to 85 Celsius.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e060G3711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eMBS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003ePressure Range\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0 - 16 bar \/ 0 - 232 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4 - 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e9.00 - 32.00 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eAngular (EN 175301-803-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eAmbient Temp\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e-40 to 85 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e0.156 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary advantage of the 4 - 20 mA output signal in this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCurrent-based output signals are highly resistant to electromagnetic interference over long cable runs, making them superior to voltage-based signals in complex industrial environments filled with high-voltage machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 060G3711 be installed in corrosive environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the wetted parts are made of high-grade stainless steel, providing excellent durability against various media, including water, oil, and compatible gases. Always confirm media compatibility with your specific process fluid.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the IP65 rating affect installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IP65 rating ensures the transmitter is dust-tight and protected against low-pressure water jets. While robust, ensure the electrical connector is properly seated and tightened to maintain the integrity of the enclosure seal.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e For optimal performance and to minimize the impact of sediment or air traps, mount the pressure transmitter vertically with the pressure connection facing downward if possible. In liquid applications, ensure the pressure line is bled of air before final commissioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e When installing the transmitter into the process piping, use the appropriate wrench on the hex-nut section of the body only. Do not rotate the housing by hand or apply force to the electrical connector during installation, as this may compromise the internal seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Grounding:\u003c\/strong\u003e To minimize the risk of signal noise, ensure the cable shield is grounded at the control cabinet end only. Avoid running signal cables alongside high-voltage power lines or variable frequency drive (VFD) cables to prevent induced interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102411022699,"sku":"060G3711","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g3711-eydoa3lkzkj.png?v=1776136941"},{"product_id":"danfoss-060g5528-mbs-3100-heavy-duty-industrial-pressure-transmitter","title":"Danfoss 060G5528 MBS 3100 Heavy-Duty Industrial Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G5528 (060G5528)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-accuracy, marine-approved compact pressure transmitter from the Danfoss MBS 3100 series. Engineered for severe industrial applications—including offshore wind turbines, marine propulsion, hydraulic power packs, and power plant cooling loops—this sensor provides field-tested consistency in tracking high-pressure fluid vectors. By maintaining an error-free 4-20 mA analog feedback loop to a central PLC or distributed control system (DCS), the 060G5528 protects critical infrastructure from over-pressure shocks, cavitation, and pipe bursts, significantly reducing the risk of system shutdowns and hardware fatigue.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe electronic architecture utilizes a piezo-resistive measuring cell housed within an acid-resistant stainless steel body. This sealed-gauge design references internal pressure parameters rather than changing atmospheric conditions, making it optimal for processes up to 250 bar. The unit undergoes rigorous autofrettage stress-testing during production, resulting in a structural overload capacity of 1500 bar to endure severe liquid hammer phenomena. Furthermore, the internal signal processing enforces clipping thresholds at 3.6 mA and 22.4 mA, allowing control systems to immediately differentiate between valid pressure data and wiring faults.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G5528\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 250 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Loop\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrecision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5% (Typical) \/ +\/- 1.0% (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStructural Overload\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProcess Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 Male (ISO 1179-2 Form E)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 100 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM20 Angular\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox 1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the benefits of a sealed gauge reference versus a standard gauge?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sealed gauge references a permanently vacuum-sealed internal cavity instead of an open atmosphere vent. In high-pressure applications, this prevents humidity ingress and particulate buildup behind the diaphragm, maintaining accuracy during washdowns or marine exposure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the clipping thresholds aid process diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor limits its output signal. By clamping values at 3.6 mA and 22.4 mA, the DCS or PLC logic can instantly isolate hardware defects or loop failures from valid process pressure variations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the zero point or span be adjusted in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this model features a factory-calibrated, fully welded design with no mechanical potentiometers. This fixed architecture ensures long-term calibration stability and prevents signal drift caused by vibration.\u003c\/p\u003e\n\u003ch3\u003eField Deployment \u0026amp; Commissioning Protocol\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Seating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThread the G 1\/4 process connection into a port machined to DIN 3852-E or ISO 1179-2 Form E standards. Use a calibrated wrench on the 27 mm hex flats to tighten the transmitter to 35 Nm. Never rotate the upper transmitter body by hand during installation, as this can compromise internal seals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify correct polarity during loop connection; terminate the positive power lead to Pin 1 and the shared return to Pin 2 of the M20 connector. Ensure the rubber perimeter gasket is seated flat when closing the housing to maintain the IP65 seal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePulsation Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the sensor features a high overload capacity, constant exposure to cavitation or rapid liquid hammer will eventually cause fatigue. In high-velocity hydraulic lines or systems with fast-acting valves, integrate a mechanical pulse snubber upstream to protect the process diaphragm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102412104043,"sku":"060G5528","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g5528-ddpwmawszl5.png?v=1776136943"},{"product_id":"060g1111-danfoss-mbs-3000-compact-pressure-transmitter","title":"060G1111 Danfoss MBS 3000 Compact Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1111 (060G1111)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial pressure transmitter from the renowned Danfoss MBS 3000 series, specifically engineered for 0 - 250 bar applications. Designed to provide reliable measurements in severe hydraulic and industrial environments, this unit converts gauge pressure into a precise 4 - 20 mA signal. Its compact, acid-resistant stainless steel construction makes it indispensable for pressure monitoring in heavy-duty machinery, pumping systems, and water treatment facilities. In complex automation architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1111\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical feedback component, ensuring system safety and optimizing process efficiency to significantly minimize equipment downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model nomenclature for the 060G1111 reflects its specific technical build and performance envelope:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e060G\u003c\/strong\u003e: Global series code for Danfoss specialized industrial sensing components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e34\u003c\/strong\u003e: Integrated code for the 0 to 250 bar pressure measurement range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Denotes the Pressure Reference as Gauge (relative to atmospheric pressure).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Standardized 4 - 20 mA analog output signal for universal PLC compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Electrical interface utilizing the Plug Pg 9 (standardized under EN 175301-803).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAB04\u003c\/strong\u003e: Mechanical interface specification for G 1\/4 A (compliant with EN 837 standards).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e060G1111\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark \/ EU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 250 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (AISI 316L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 060G1111 require routine recalibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDue to its excellent long-term stability—typically better than 0.1 percent FS per year—the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1111\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires minimal maintenance. However, in high-cycle hydraulic applications, an annual calibration check is recommended to verify accuracy against local safety standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this transmitter protected against electrical surges?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MBS 3000 series is designed with high EMI\/RFI immunity and built-in protection against reverse polarity. It meets stringent industrial EMC requirements to ensure signal stability in environments with heavy electrical noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 060G1111 handle pressure spikes above 250 bar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features a high static overpressure limit. While it is rated for 0 - 250 bar measurement, it can typically withstand significant overpressure without rupture, though sustained operation above the rated range may cause a shift in the zero point.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCavitation and Pressure Peak Mitigation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn hydraulic systems characterized by rapid valve closures or pump pulsations, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1111\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshould be installed with a pulse snubber. High-velocity liquid hammers can exceed the burst pressure of the sensing element; a snubber effectively dampens these micro-second peaks without affecting the response time of the 4 - 20 mA signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrientation and Environmental Sealing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the transmitter is vibration-stable and rated IP65, ensure the Pg 9 plug is oriented so that the cable enters from below. This creates a \"drip loop\" that prevents moisture from traveling along the cable and pooling at the electrical interface. Always use the provided gasket between the plug and the transmitter body to maintain the environmental seal.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102412366187,"sku":"060G1111","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1111-jpuqa11cazo.png?v=1776136910"},{"product_id":"danfoss-060g3831-mbs-3000-pressure-transmitter","title":"Danfoss 060G3831 MBS 3000 Pressure Transmitter","description":"\u003ch3\u003eFunctional Profile and Industrial Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G3831 (060G3831)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty industrial pressure transmitter belonging to the renowned Danfoss MBS 3000 series. Engineered to deliver dependable pressure monitoring across severe industrial environments, this instrument is highly optimized for hydraulic systems, water utilities, pneumatic distribution lines, and general mechanical engineering processes.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G3831\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasures a relative (gauge) pressure range from 0 to 4 bar, converting physical force into a stable, linear 0 to 10 VDC voltage output signal.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-51 citation-end-51\"\u003eConstructed with an acid-resistant stainless steel enclosure (AISI 316L) and fully welded wetted parts, the transmitter eliminates internal sealing rings to safeguard against fluid leakage.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis robust structural barrier maintains tight control loop integrity and significantly prevents localized process fluid loss in hazardous, high-vibration applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eOperational Features and Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-50\"\u003e\u003c\/span\u003e\u003cstrong\u003eMBS 3000:\u003c\/strong\u003e\u003cspan class=\"citation-50 citation-end-50\"\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the core compact, general-purpose heavy-duty industrial pressure transmitter platform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the calibrated measuring span of 0 to 4 bar (0 to 58 psi).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1:\u003c\/strong\u003e\u003cspan class=\"citation-49 citation-end-49\"\u003e\u003cspan\u003e \u003c\/span\u003eSets the measurement reference type to Gauge (Relative pressure measured against current atmospheric pressure).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-48\"\u003e\u003c\/span\u003e\u003cstrong\u003e5:\u003c\/strong\u003e\u003cspan class=\"citation-48 citation-end-48\"\u003e\u003cspan\u003e \u003c\/span\u003eDefines the scaled analog output electronic circuit as a 0 to 10 V high-impedance voltage signal.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance Field\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDocumented Technical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000-1615-1 (060G3831)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmitter Subtype\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Pressure Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 4 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Output Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAngular plug connector Pg 9 (EN 175301-803 Form A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 to 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Overload Pressure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCombined Accuracy Limit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e0.5% FS (Typical) \/ \u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e1.0% FS (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Material Base\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless steel (AISI 316L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngress Protection Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65 (Fulfilled with matching mating plug attached)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComplete Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations and Logistics FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary electrical supply restrictions for a 0 to 10 V output loop?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-47 citation-end-47\"\u003eUnlike 4 to 20 mA loop-powered current transmitters that operate on lower minimum voltages, the 0 to 10 V voltage variant of the 060G3831 requires a stable excitation input supply voltage between 15 and 32 VDC.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDropping the supply below 15 VDC will clip the high-end output voltage tracking capability, leading to measurement saturation before the physical 4 bar threshold is achieved.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific field benefits does the fully welded wetted cavity provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter uses a laser-welded diaphragm configuration fabricated from AISI 316L stainless steel. Eliminating internal rubber O-rings or synthetic elastomeric gaskets removes typical mechanical degradation points, allowing long-term chemical compatibility with aggressive oils, gases, and water-glycol mixtures without risk of seal crystallization or chemical blowouts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the system log a 1.5 kg shipping weight for a 0.15 kg compact sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1.5 kg specification encompasses heavy-duty distribution packaging. Since industrial pressure cells contain precise piezoresistive element layers and digital temperature compensation chips, the component is wrapped in static-dissipative material, nested inside molded corrugated cells, and boxed with dedicated installation calibration certs to endure international shipping lines.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCritical Field Installation and Termination Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-46\"\u003e\u003c\/span\u003e\u003cstrong\u003eElectrical Plug Alignment and IP65 Preservation:\u003c\/strong\u003e\u003cspan class=\"citation-46 citation-end-46\"\u003e\u003cspan\u003e \u003c\/span\u003eConnect the instrument via the integrated EN 175301-803 Form A angular connector.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the rubber sealing profile gasket is aligned completely square between the plug body and the transmitter terminal face prior to tightening the central retention screw. Improper alignment or incomplete tightening drops the ingress barrier below IP65, risking fluid tracking failures inside the housing.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-45\"\u003e\u003c\/span\u003e\u003cstrong\u003eMechanical Torque and Thread Seal Standards:\u003c\/strong\u003e\u003cspan class=\"citation-45 citation-end-45\"\u003e\u003cspan\u003e \u003c\/span\u003eThread the pressure connection cleanly into the mating port using a standard 27 mm hex wrench.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eApply a maximum tightening torque appropriate for G 1\/4 industrial port seals to avoid structural threads cross-threading. Do not apply rotational forces directly to the upper cylindrical body housing, as doing so can tear the internal wire bonds away from the terminal header pins.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Temperature and Condensation Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compensated temperature range spans from 0 to 80 deg C, while the physical wetted medium can operate safely from -40 to 85 deg C. If the field deployment zone is subjected to freezing process media or rapid ambient temperature transitions, trace-heat or insulate the sensing line impulse piping to prevent liquid freeze-ups from cracking the internal pressure diaphragm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102412628331,"sku":"060G3831","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g3831-3ewkfkgtgwg.png?v=1776136943"},{"product_id":"060g5539-danfoss-mbs-3000-industrial-pressure-transmitter","title":"060G5539 Danfoss MBS 3000 Industrial Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G5539 (060G5539)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, heavy-duty MBS 3000 series pressure transmitter engineered for use in almost all industrial applications. Designed for high-pressure hydraulic systems and industrial machinery, it converts a 0 - 400 bar measuring range into a standard 4 - 20 mA output signal. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMBS 3000-3611-1GB04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to withstand harsh environmental conditions, featuring excellent vibration stability and a high degree of EMI protection. Its robust stainless steel construction and acid-resistant housing make it an ideal choice for power plants, water treatment facilities, and mobile hydraulic equipment where long-term reliability and precision are critical for operational safety.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMBS 3000-3611-1GB04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifies the precise hardware configuration for this industrial sensor:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMBS 3000\u003c\/strong\u003e: Compact industrial pressure transmitter series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e36\u003c\/strong\u003e: Measuring range of 0 to 400 bar (0 to 40 MPa).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Pressure reference is Gauge (relative to atmospheric pressure).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Standard 4 - 20 mA current output signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Electrical connection via Plug Pg 9 (EN 175301-803-A).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGB04\u003c\/strong\u003e: Pressure connection type DIN 3852-E-G 1\/4 with integrated gasket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000-3611-1GB04 (060G5539)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 400 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 (DIN 3852-E)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 175301-803-A (Pg 9 Plug)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5% FS (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMedium Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 bar (Static)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 316L Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I wire the MBS 3000 for a 2-wire control loop?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 060G5539 utilizes a standard 2-wire configuration. Connect the positive supply voltage (+Vcc) to Pin 1 and the signal return (Output\/Ground) to Pin 2 of the EN 175301-803-A plug. Pin 3 is usually not used, and the earth terminal is for shield\/grounding.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the DIN 3852-E-G 1\/4 (GB04) connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe GB04 connection features a G 1\/4 thread with a recessed sealing face that accommodates a soft gasket (typically NBR or Viton). This provides a superior leak-proof seal compared to metal-to-metal tapered threads, especially in high-vibration hydraulic systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this transmitter suitable for high-pressure spikes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 060G5539 is rated for 400 bar with a 600 bar static overload capacity, rapid hydraulic shocks can cause damage. For systems with severe water hammer or cavitation, the use of a Danfoss MBS series with an integrated pulse snubber (such as the MBS 3050) is recommended.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the G 1\/4 DIN 3852-E connection, ensure the mating port is clean and free of burrs. Tighten the transmitter to the recommended torque of 30 Nm. Over-tightening can deform the integrated gasket and lead to leaks or internal sensing element stress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn environments with high electromagnetic interference—such as near VFDs or large motors—use shielded twisted-pair cable for the 4-20 mA loop. The shield should be grounded at the controller side only to prevent ground loops. Ensure the DIN plug gasket is properly seated to maintain the IP65 protection rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the medium temperature exceeds 85 deg C, use a siphon or capillary tube to isolate the transmitter from the heat source. For every 10 cm of uninsulated capillary tube, the medium temperature will drop significantly, protecting the internal electronics of the MBS 3000 from thermal degradation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102413414763,"sku":"060G5539","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g5539-kfyxmzrdqcs.png?v=1776136944"},{"product_id":"mbs-3000-060g1107-danfoss-compact-pressure-transmitter","title":"MBS 3000 (060G1107) Danfoss Compact Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMBS 3000 (060G1107)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty, compact pressure transmitter designed for demanding industrial environments. As part of the gold-standard MBS 3000 series, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDanfoss 060G1107 (060G1107)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a precise 4–20 mA output signal across a high-pressure range of 0–100 bar. This transmitter is specifically engineered for B2B applications in high-pressure hydraulics, industrial washing systems, and heavy-duty compressors where durability against vibration, pressure peaks, and electromagnetic interference is mandatory for system stability and safety.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe MBS 3000-3011-1AB04 is built to last, featuring a piezo-resistive silicon sensing element protected by a 316L stainless steel enclosure. It utilizes a gauge (relative) pressure reference, meaning it measures system pressure against the current atmospheric pressure. The electrical connection follows the industry-standard EN 175301-803-A (Plug Pg 9), allowing for easy field replacement and secure wiring. The G ¼ A pressure connection (EN 837) ensures compatibility with most standard high-pressure manifolds and piping systems. Its advanced internal design offers superior EMI\/RFI protection, ensuring signal integrity even near high-frequency industrial drives.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000 (060G1107)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 100 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA (2-wire)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 - 32 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803-A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG ¼ A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy (Typ.)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 0.5% FS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to 85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (AISI 316L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 060G1107 handle pressure surges beyond 100 bar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MBS 3000 series is designed with significant overpressure capabilities. However, to prevent permanent zero-point shift or diaphragm damage, it is recommended to keep operating peaks within the manufacturer's specified overpressure limit (typically 3x to 6x the measuring range depending on the specific model variant).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the transmitter suitable for mobile hydraulic applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. Its high resistance to shock (500g \/ 1ms) and vibration (20g, 20Hz–2kHz) makes it an excellent choice for mobile machinery, such as excavators, cranes, and agricultural equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the transmitter require calibration upon arrival?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the MBS 3000 is factory-calibrated and temperature-compensated. It is ready for \"plug-and-play\" installation. Periodic verification is recommended according to your facility's quality management protocols.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Scheme:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis is a 2-wire transmitter. Connect the positive (+) lead from your 24V DC power supply to Pin 1 and the signal return (-) to Pin 2. Always use shielded cable in environments with high electrical noise to maintain the ± 0.5% accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mounting the G ¼ A thread, use a 27 mm wrench on the hex flats of the transmitter body. Ensure a proper seal using a copper or bonded washer. Never tighten the transmitter by gripping the electrical plug or the stainless steel housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondensation Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor installations in high-humidity areas or outdoor environments, mount the transmitter with the electrical connector pointing downwards. This prevents moisture from collecting at the cable entry and potentially breaching the IP65 seal over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102413644139,"sku":"060G1107","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1107-ka1cn01b5dr.png?v=1776136907"},{"product_id":"060g1109-danfoss-mbs-3000-pressure-transmitter","title":"060G1109 Danfoss MBS 3000 Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1109 (060G1109)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty Danfoss MBS 3000 series pressure transmitter engineered for precision measurement in demanding industrial environments. Designed specifically for hydraulic applications, boiler systems, and water treatment plants, this compact sensor converts mechanical pressure into a stable 4-20 mA analog signal. By utilizing advanced piezo-resistive technology and high-grade stainless steel construction, the 060G1109 ensures long-term stability and EMI\/RFI immunity. In critical sectors like oil refining and power generation, this transmitter plays a vital role in real-time pressure monitoring, effectively preventing equipment overpressure and reducing unscheduled downtime caused by sensor fatigue or signal drift.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model designation 060G1109 follows the Danfoss MBS 3000 configuration logic as detailed below:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e060G\u003c\/strong\u003e: Global product prefix for the Danfoss Industrial Transmitter series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e36\u003c\/strong\u003e: Measuring range identifier, signifying a 0 to 400 bar pressure span.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Pressure reference indicating Gauge (relative) pressure measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Output signal type, configured for the industry-standard 4-20 mA current loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAB04\u003c\/strong\u003e: Mechanical pressure connection specification, utilizing G 1\/4 A (EN 837) threading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Electrical connection type, featuring a Plug Pg 9 (EN 175301-803-A) interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G1109\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark \/ EU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 400 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5 percent FS (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompensated Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 80 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the MBS 3000 handle pressure peaks in hydraulic systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 060G1109 features a robust design that provides excellent vibration stability and high overpressure capability. For systems with extreme cavitation or liquid hammer, it is recommended to install a Danfoss pulse snubber to protect the sensing element.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the Gauge (relative) pressure reference?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA gauge pressure transmitter measures pressure relative to the atmospheric pressure at the installation site. This ensures that the 060G1109 reads zero bar when the system is vented to the atmosphere, regardless of altitude changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 060G1109 compatible with corrosive media?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe wetted parts are manufactured from high-quality stainless steel (AISI 316L). While compatible with most hydraulic oils and non-aggressive gases, users must verify chemical compatibility if using the device with highly acidic or alkaline fluids.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Sealing Integrity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installing the G 1\/4 A pressure connection, ensure the use of a proper copper or bonded seal washer compliant with EN 837. Apply a maximum torque of 30 Nm to prevent stripping the threads or damaging the internal sensor housing. Always mount the transmitter in a position that prevents moisture accumulation within the electrical connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Interference Mitigation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo maintain signal integrity in high-noise environments (near VFDs or large motors), use shielded twisted-pair cabling for the 4-20 mA loop. The shield should be grounded at the controller end only to avoid ground loops. Ensure the Pg 9 plug is fully seated and the retaining screw is tightened to maintain the IP65 ingress protection rating.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102414168427,"sku":"060G1109","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1109-qaxthbnmlex.png?v=1776136908"},{"product_id":"060g1368-danfoss-mbs-3000-industrial-pressure-transmitter","title":"060G1368 Danfoss MBS 3000 Industrial Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1368 (060G1368)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision pressure transmitter from the Danfoss MBS 3000 series, specifically engineered for demanding industrial and hydraulic applications. This gauge reference sensor provides a reliable 4 to 20 mA current output, ensuring accurate monitoring of liquid and gaseous media even in high-temperature environments reaching up to 100 deg C. Designed for long-term stability and resistance to electromagnetic interference, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1368\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical asset for power plants, water distribution systems, and manufacturing lines. Its robust stainless steel construction and IP65-rated enclosure provide exceptional protection against vibration and moisture, minimizing system downtime and optimizing process control efficiency in the most rigorous B2B industrial settings.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe MBS 3000 series is built to deliver high performance through a simplified, durable hardware architecture.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a maximum accuracy of 0.5 percent FS (Full Scale), providing precise data for sensitive control loops without the need for manual zero-point or span adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of operating in ambient temperatures ranging from -40 to 100 deg C, making it suitable for mounting near high-heat machinery or in extreme climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a standard G 1\/4 (EN 837) pressure connection with a 27 mm HEX, ensuring a secure and leak-proof fit in standard industrial manifolds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Clipping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated high (22.4 mA) and low (3.6 mA) clipping levels allow the controller to instantly identify sensor malfunctions or over-range conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures an angular connector with a Pg 11 cable entry, providing a standardized and rugged electrical termination that maintains an IP65 environmental rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G1368\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Pressure Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 percent FS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverload Pressure Max\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Temp Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 100 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAngular Connector (Pg 11)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the supply pins correspond to the angular connector wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1368\u003c\/strong\u003e, Pin 1 is designated for the + supply and Pin 2 serves as the - common (signal return). This standard two-wire configuration simplifies the current loop wiring to the PLC or analog input module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter require field calibration for the zero point?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this model features a fixed zero point and span. The high-precision laser-calibrated electronics ensure the sensor remains within the 0.5 percent accuracy specification throughout its service life without the need for manual adjustment screws.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the non-flush diaphragm in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe non-flush diaphragm design is optimized for clean liquids and gases. It provides a robust sensing surface that is less susceptible to mechanical damage from high-velocity flow, though it is not recommended for highly viscous or crystallizing media which may clog the pressure port.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Seal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen assembling the Pg 11 angular connector, ensure the internal rubber gasket is seated correctly before tightening the center screw. This is vital to maintain the IP65 rating and prevent moisture from corroding the internal terminals. Use a shielded, twisted-pair cable to protect the 4 to 20 mA signal from electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse a 27 mm wrench on the HEX part of the pressure connection for installation. Do not use the transmitter body (the upper housing) to tighten the unit into the manifold, as this can damage the internal sensing element and void the accuracy specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the unit is rated for ambient temperatures up to 100 deg C, if the process media temperature consistently exceeds these limits, consider using a pigtail siphon or a capillary tube extension. This provides a cooling buffer that ensures the electronics remain within the specified thermal operating window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102415217003,"sku":"060G1368","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1368-zxwj0jviqof.png?v=1776136914"},{"product_id":"danfoss-060g1540-mbs-3000-compact-pressure-transmitter-0-6-bar","title":"Danfoss 060G1540 MBS 3000 Compact Pressure Transmitter 0-6 Bar","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1540 (060G1540)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, compact pressure transmitter from the renowned Danfoss MBS 3000 series, specifically engineered for use in a vast range of industrial applications. This precision-engineered sensor measures pressure across a 0 to 6 bar (0 to 87 psi) range, converting the physical input into a standard 4 to 20 mA current signal. Designed for reliability in harsh environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1540\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical component for hydraulic systems, water treatment plants, and air compressors. Its robust construction ensures exceptional vibration stability and long-term signal consistency, effectively reducing maintenance overhead and preventing costly system downtime in high-demand B2B industrial sectors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe MBS 3000 series architecture focuses on balancing precision with mechanical durability to thrive in volatile industrial conditions.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a linear 4 to 20 mA current output, offering high immunity to electromagnetic interference (EMI) and making it ideal for long-distance signal transmission to PLCs or remote displays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBoasts an impressive maximum overload pressure of 36 bar (522 psi), which is six times its nominal operating range, providing a massive safety margin against catastrophic hydraulic spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates on a wide supply voltage range from 9 to 32 VDC, allowing for seamless integration into diverse power architectures without the need for additional voltage regulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a standard angular connector (Male\/Female) that facilitates rapid field installation and secure electrical contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMedia Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed to withstand cavitation, liquid hammer, and pressure peaks, ensuring the internal sensing element remains accurate throughout its operational life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G1540 (MBS 3000)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 6 bar (0 to 87 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverload Pressure Max\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 bar (522 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAngular Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.186 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 060G1540 handle extreme pressure spikes in hydraulic lines?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MBS 3000 is built with a high overload pressure rating of 36 bar. This means the sensor can withstand transient spikes up to six times its rated 6 bar capacity without mechanical failure or permanent calibration shift, making it highly reliable in systems with rapid valve closures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat electrical connection is required for this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model uses a standard industrial angular connector. It provides a \"Male and Female\" interface, meaning it typically includes the plug-and-socket set required to secure the cable, ensuring an IP-rated seal that protects against dust and moisture ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this sensor be used in outdoor installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MBS 3000 series is designed for rugged industrial use. When properly installed with its angular connector and appropriate cable, it provides high resistance to environmental factors. However, ensure the ambient temperature stays within the standard -40 to 85 deg C operating range.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Port Orientation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor gas applications, mount the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1540\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the pressure connection facing upwards to allow any condensate to drain away from the sensing element. For liquid applications, mount it with the connection facing downwards or sideways to prevent air pockets from affecting the 4 to 20 mA signal accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI Protection and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure maximum signal precision, use a shielded twisted-pair cable for the 4 to 20 mA loop. The shield should be connected to the functional earth of the PLC or control cabinet to dissipate high-frequency noise common in environments with variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealing and Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the transmitter into a threaded manifold, use the appropriate sealing washer or thread sealant recommended for your specific medium. Avoid over-tightening, as excessive torque can stress the stainless steel housing and potentially lead to a zero-point shift in the reported pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102415282539,"sku":"060G1540","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1540-ycw0qxhcxqp.png?v=1776136919"},{"product_id":"danfoss-060g5902-mbs-3000-compact-pressure-transmitter-vacuum-range","title":"Danfoss 060G5902 MBS 3000 Compact Pressure Transmitter (Vacuum Range)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDanfoss 060G5902 (MBS 3000)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, compact pressure transmitter specifically designed for vacuum measurement applications. With a sensing range of -1 to 0 bar (-14.5 to 0 psi), this module is a staple in industrial automation for monitoring suction systems, vacuum pumps, and specialized pneumatic circuits. Engineered to withstand the rigors of heavy-duty industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G5902\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a piezoresistive silicon sensing element and high-grade stainless steel construction (AISI 316L) to ensure long-term stability and resistance to corrosion. Its 4 to 20 mA analog output provides a reliable, noise-immune signal to PLCs and DCS systems, making it an essential component for precise process control in food processing, packaging, and chemical manufacturing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe MBS 3000 series is defined by its robust mechanical design and excellent vibration stability. The 060G5902 features an EN 175301-803-A angular connector (often referred to as a DIN plug), which provides an IP65 enclosure rating, protecting the internal electronics from dust and low-pressure water jets.\u003c\/p\u003e\n\u003cp\u003eInternally, the transmitter is laser-calibrated and temperature-compensated to maintain high accuracy across a broad thermal range (-40 to 85 deg C). It operates on a flexible DC supply (9 to 32 VDC), allowing it to be powered directly from standard industrial control loops. The vacuum-rated sensing diaphragm is designed to handle pressure peaks and cavitation without drift, ensuring that vacuum-sensitive processes—such as suction pick-and-place or distillation—maintain consistent performance throughout their lifecycle.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G5902 (MBS 3000)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-1 to 0 bar (-14.5 to 0 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelative (Vacuum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 to 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAngular Connector (EN 175301-803-A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWetted Parts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (AISI 316L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.153 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 25 mm diameter x 90 mm length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the 060G5902 suitable for measuring liquid vacuum?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes. The AISI 316L stainless steel wetted parts are compatible with most non-corrosive liquids and gases. It is commonly used in pump cavitation monitoring and liquid suction lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How do I wire the angular connector for a 4-20 mA loop?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: For the standard EN 175301-803-A connector, Pin 1 is typically the Positive (+) Supply and Pin 2 is the Output Signal (Return). Always refer to the wiring diagram laser-etched on the transmitter body to verify local pinouts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What happens if the pressure exceeds 0 bar (positive pressure)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The MBS 3000 has a defined overpressure limit (typically 2-3 times the full-scale range). While the output signal will saturate at 20 mA once 0 bar is reached, the sensor can withstand minor positive pressure transients without mechanical failure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration and Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe MBS 3000 is highly resistant to vibration, but for optimal life expectancy, mount the transmitter in a position that minimizes direct mechanical shock. When installing in high-vibration piping, consider using a capillary tube or flexible mounting bracket to decouple the sensor from the source.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVacuum Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the 060G5902, use a high-quality thread sealant (such as PTFE tape or a liquid sealant rated for vacuum) to prevent atmospheric air leakage into the system. Even a microscopic leak will cause the transmitter to show an incorrect \"High\" vacuum reading (closer to 0 bar).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the transmitter is rated to 85 deg C, prolonged exposure to extreme temperatures can shorten the life of the internal capacitors. If the process media temperature exceeds 100 deg C, utilize a cooling pigtail (syphon) to protect the sensing diaphragm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 060G5902 is distinguished by its excellent electromagnetic compatibility (EMC), meeting the stringent requirements of EU directives for industrial environments. This ensures that the 4 to 20 mA signal remains stable even when the transmitter is mounted near frequency converters or large motors. Furthermore, the compact \"hex-nut\" body design allows for installation in tight manifolds where traditional, bulkier transmitters would not fit. Its proven reliability in vacuum applications makes it a \"fit and forget\" solution for engineers looking to reduce maintenance overhead in automated production lines.\u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102416691563,"sku":"060G5902","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g5902-zosai13bpld.png?v=1776136945"},{"product_id":"mbs-3000-3811-1ab04-danfoss-060g1110-pressure-transmitter","title":"MBS 3000-3811-1AB04 Danfoss 060G1110 Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1110 (060G1110)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDanfoss\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMBS 3000 series pressure transmitter, specifically engineered for high-pressure industrial applications. Designed to operate in the most demanding environments, such as hydraulic power units, water treatment high-pressure pumps, and industrial engine testing, this transmitter converts physical pressure into a stable electrical signal. With a measuring range of 0 to 600 bar, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMBS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the precision required for high-tonnage machinery and power protection systems. Its robust design is optimized to resist vibration and thermal shocks, ensuring critical system data remains accurate, thereby preventing over-pressure conditions and extending the operational life of hydraulic components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for extreme durability and standard industrial integration.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensing Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing a gauge (relative) pressure reference, the unit provides accurate 0 to 600 bar measurement relative to atmospheric pressure, ideal for high-pressure hydraulic circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a standard 4 - 20 mA analog output, offering high noise immunity and long-distance transmission capability for direct connection to PLC or DCS analog input modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a G 1\/4 A (EN 837) pressure connection, a standard industrial thread that ensures a leak-proof seal in high-pressure manifolds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUses a Plug Pg 9 (EN 175301-803-A) connector, allowing for rapid field replacement and a high degree of protection against dust and moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal sensing element is designed for compatibility with a wide range of industrial media, including oils and non-corrosive gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000 - 3811 - 1 AB04\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G1110\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 600 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the 060G1110 be protected against pressure spikes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn hydraulic systems where water hammer or sudden pressure surges occur, it is highly recommended to install a Danfoss pulse snubber at the G 1\/4 A connection. This prevents the high-frequency 600 bar spikes from damaging the internal sensing diaphragm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transmitter be used in outdoor environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, when the Pg 9 plug is correctly installed with its gasket and tightened, the unit achieves an IP65 rating. This provides sufficient protection against rain and splashing water, making it suitable for outdoor industrial installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 060G1110 require periodic calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the MBS 3000 series is laser-calibrated at the factory for life-long stability, industrial standards typically suggest a verification check every 12 to 24 months to ensure the 4 - 20 mA loop remains within the specified tolerance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealing and Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the G 1\/4 A connection, ensure the use of a suitable copper or bonded seal washer. Over-torquing can distort the pressure port, while under-torquing may lead to high-pressure leaks which are hazardous in 600 bar systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Power Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4 - 20 mA output is a 2-wire loop. Ensure the DC power supply (typically 24 VDC) is stable. If the cable run exceeds 100 meters, account for the voltage drop across the wire to ensure the transmitter still receives at least 9 VDC at full 20 mA output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the transmitter is mounted directly on a high-vibration pump or engine, use a flexible capillary tube between the pressure source and the transmitter. This mechanical isolation protects the internal electronics from fatigue and ensures signal stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418297195,"sku":"060G1110","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1110-zjmzdhwfw3o.png?v=1776136910"},{"product_id":"danfoss-060g2420-mbs-series-flush-diaphragm-pressure-transmitter","title":"Danfoss 060G2420 MBS Series Flush Diaphragm Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2420 (060G2420)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision pressure transmitter engineered for industrial applications requiring a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFlush Diaphragm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterface. This design is critical for measuring the pressure of high-viscosity, crystallizing, or contaminated media in sectors such as food and beverage processing, wastewater treatment, and chemical manufacturing. With a low-pressure range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 0.6 bar\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2420\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers an industry-leading typical accuracy of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.2% FS\u003c\/strong\u003e, ensuring tight process control and preventing costly material waste. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATEX approval\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epermits safe operation in potentially explosive atmospheres, making it a reliable solution for monitoring tank levels or pipeline pressures in hazardous industrial zones.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2420\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a piezoresistive sensing element protected by a robust flush-mounted diaphragm. This configuration prevents media build-up and clogging, which often plague standard pressure ports in \"dirty\" processes. The transmitter outputs a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eanalog signal, featuring a low clipping level of 3.6 mA and a high clipping level of 22.4 mA for advanced diagnostic capabilities. Encased in an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP65\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erated housing with an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEN 175301-803-A (DIN-plug)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eelectrical connection, the device is designed for rapid installation and resistance to mechanical vibration. The internal electronics are temperature-compensated between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 80 deg C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain signal integrity despite ambient thermal fluctuations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G2420\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 0.6 bar (0 to 60 kPa)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 % FS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDiaphragm Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlush Diaphragm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-plug (EN 175301-803-A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 bar (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.344 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the flush diaphragm essential for this specific model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe flush diaphragm eliminates the \"pressure cavity\" found in standard sensors. This prevents thick or particulate-heavy fluids (like pulp, sludge, or adhesives) from hardening inside the sensor port, which would otherwise lead to drift or total sensor failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 060G2420 require a separate safety barrier for ATEX zones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While this unit carries ATEX approval for hazardous areas, it must be installed in conjunction with a certified intrinsically safe barrier or zener barrier if the specific zone classification requires limited energy spark protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 4 ms response time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA 4 ms response time allows the transmitter to detect rapid pressure spikes or \"water hammer\" effects in pipelines. This high-speed feedback is vital for automated safety systems to trigger emergency shut-off valves and protect downstream equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealing and Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the 41 mm HEX pressure connection, ensure the sealing gasket is compatible with the process media. Use a calibrated torque wrench to avoid over-tightening, which can distort the flush diaphragm and cause a zero-point shift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCleaning Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause the diaphragm is exposed, never use sharp objects (like screwdrivers or wire brushes) to clean the sensor face. Use a soft cloth and a compatible solvent to prevent scratching the thin metallic membrane, which could compromise accuracy and corrosion resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring for Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn environments with high electromagnetic interference (EMI)—such as near large VFDs or motors—use twisted-pair shielded cable for the 4-20 mA loop. The shield should be grounded at the PLC\/Controller side only to prevent ground loops that could distort the 0.2% accuracy performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419214699,"sku":"060G2420","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g2420-cjbculgjkje.png?v=1776136937"},{"product_id":"mbs-3000-danfoss-060g1122-low-pressure-transmitter","title":"MBS 3000 Danfoss 060G1122 Low-Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1122 (060G1122)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision-engineered MBS 3000 series pressure transmitter from Danfoss, designed specifically for low-pressure industrial monitoring. This unit converts a measuring range of 0 - 2.5 bar into a high-stability 4 - 20 mA analog output signal. Built to withstand the rigors of industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1122\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a piezo-resistive sensing element that provides excellent repeatability and long-term stability. It is an ideal solution for applications such as tank level measurement, low-pressure pump control, and pneumatic monitoring where accuracy in a narrow pressure window is essential to maintaining process efficiency and preventing system errors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eAs a part of the MBS 3000 \"standard\" industrial program, this transmitter is built for durability and ease of integration. It utilizes a G 1\/4 A (EN 837) pressure connection, a robust threaded interface that ensures a reliable seal even under vibration. The electrical interface is handled via a standard Pg 9 (EN 175301-803-A) plug, which is highly regarded for its secure, industrial-grade connectivity. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1122\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Gauge (relative) pressure transmitter, meaning it measures system pressure in relation to current atmospheric conditions. This makes it particularly effective for open-loop ventilation systems or liquid storage tanks where maintaining a specific head pressure relative to the environment is required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G1122\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000 - 1411 - 1 AB04\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 2.5 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803-A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow accurate is the 060G1122 for low-pressure tank leveling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MBS 3000 series typically features a total error band of plus\/minus 1% FS (Full Scale) across the compensated temperature range. For a 2.5 bar range, this provides the high resolution necessary for precise liquid level monitoring in medium-sized industrial tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transmitter handle media with high temperatures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1122\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis rated for medium temperatures between -40 and 85 deg C. If your application involves steam or very hot liquids, it is recommended to use a cooling syphon or capillary tube to ensure the medium temperature at the sensor face stays within these operational limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Pg 9 plug included with the unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenerally, Danfoss MBS 3000 transmitters of this code include the female mating plug. However, for a complete IP65 seal, the user must ensure the cable used is compatible with the Pg 9 gland size and that the internal gasket is correctly seated during final installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Port Orientation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen measuring gas or air, install the transmitter with the pressure connection pointing downwards to allow any moisture or condensate to drain away from the sensor. For liquid applications, mount the unit horizontally or vertically to prevent air pockets from being trapped against the sensing diaphragm, which can cause reading fluctuations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Loop Load:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure your PLC or controller's input impedance, combined with the cable resistance, does not exceed the maximum allowable load for the 4 - 20 mA loop. Typically, with a 24 VDC supply, the MBS 3000 can support a total loop resistance of approximately 600 - 700 Ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealing Best Practices:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the G 1\/4 A thread, always use a new copper or bonded seal (Dowty washer). Avoid over-tightening; use a calibrated torque wrench to apply approximately 25 Nm of torque to achieve a gas-tight seal without stressing the transmitter's stainless steel housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419771755,"sku":"060G1122","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1122-h0rqrikjrik.png?v=1776136911"},{"product_id":"mbs-3000-danfoss-060g1105-industrial-pressure-transmitter","title":"MBS 3000 Danfoss 060G1105 Industrial Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1105 (060G1105)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact yet heavy-duty MBS 3000 series pressure transmitter engineered by Danfoss to provide reliable pressure measurement in almost all industrial applications. This model is designed to withstand harsh environmental conditions, including severe medium temperatures and high levels of electromagnetic interference. By converting a 0 - 40 bar gauge pressure range into a standardized 4 - 20 mA output signal, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures high-fidelity data transmission to remote PLC or DCS systems. Its robust design is optimized for hydraulic systems, air compressors, and general industrial machinery where accuracy and vibration resistance are critical to preventing system failure and reducing maintenance overhead.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe MBS 3000 platform utilizes a piezo-resistive sensing element, which offers superior stability and protection against pressure peaks. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration specifically features a G 1\/4 A (EN 837) pressure connection, a standard in European hydraulic and pneumatic interfaces, ensuring a leak-proof mechanical fit. For electrical integration, it employs the widely recognized Pg 9 (EN 175301-803) plug, facilitating quick installation and service. As a \"Gauge\" (relative) pressure transmitter, it references the ambient atmospheric pressure, making it perfectly suited for open-loop systems where monitoring the internal pressure relative to the environment is the primary control objective. The internal electronics are laser-calibrated to maintain high linearity throughout the 40 bar measuring span.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G1105\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000 - 2611 - 1 AB04\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 40 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803-A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 060G1105 handle hydraulic spikes or cavitation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MBS 3000 series is designed with high overpressure capabilities. However, for systems with frequent hydraulic shocks, it is recommended to use the MBS 3050 variant (which includes an integrated pulse-snubber) or install a separate damping orifice to protect the piezo-resistive sensor from mechanical fatigue.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable length for the 4 - 20 mA signal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses a current loop signal, it can typically transmit data over distances exceeding 500 meters without significant signal loss, provided the loop resistance (including cable and controller input resistance) does not exceed the transmitter's maximum load capability at the specific supply voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the Pg 9 plug be replaced with a different electrical interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 060G1105 is built with a fixed Pg 9 housing. To change the electrical interface (e.g., to an M12 connector), you would need to specify a different sub-model within the MBS 3000 series, as the housing and internal wiring are factory-sealed to maintain its industrial IP rating.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Torque \u0026amp; Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mounting the G 1\/4 A thread, use a copper or bonded seal washer to ensure a pressure-tight connection. Tighten to the specified torque (typically 20-30 Nm for this thread type) to avoid stripping the threads or damaging the internal sensing element through excessive mechanical stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the IP65 protection rating of the Pg 9 plug, ensure the included rubber gasket is seated correctly between the plug and the transmitter body. Ensure the cable gland is tightened sufficiently around the cable jacket to prevent moisture ingress through capillary action.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn environments with high-frequency noise (such as near Variable Frequency Drives), use a shielded cable for the 4 - 20 mA loop. The shield should be connected to the functional ground at the control cabinet end only to prevent ground loops that could introduce offset errors in the pressure reading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419968363,"sku":"060G1105","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1105-evw0szktrgg.png?v=1776136906"}],"url":"https:\/\/www.plcprotech.com\/collections\/danfoss-mbs-3300-3350-pressure-transmitter.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}