{"title":"Danfoss VLT Inverters","description":"    \u003cstrong\u003eDanfoss VLT\u003c\/strong\u003e represents the benchmark for high-performance \u003cstrong\u003eVariable Frequency Drives (VFD)\u003c\/strong\u003e, engineered for maximum uptime and energy efficiency across diverse industrial environments. This collection features the full spectrum of VLT technology: from the compact \u003cstrong\u003eVLT Micro Drive FC 51\u003c\/strong\u003e and the versatile \u003cstrong\u003eMidi Drive FC 280\u003c\/strong\u003e to the application-optimized \u003cstrong\u003eHVAC Drive FC 102\u003c\/strong\u003e, \u003cstrong\u003eAQUA Drive FC 202\u003c\/strong\u003e, and the high-precision \u003cstrong\u003eAutomationDrive FC 302\u003c\/strong\u003e. Designed with a modular platform and advanced motor independence, these inverters provide robust speed and torque control for fans, pumps, conveyors, and complex motion systems.","products":[{"product_id":"fc-101p22kt4e20-danfoss-vlt-hvac-basic-drive-22kw","title":"FC-101P22KT4E20 Danfoss VLT HVAC Basic Drive 22kW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-101P22KT4E20 (FC101P22KT4E20)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency VLT HVAC Basic Drive specifically engineered to optimize fan and pump performance in modern building automation systems. Delivering a robust 22.0 kW (30.0 hp) shaft output, this drive is a cornerstone for HVAC infrastructure in commercial complexes, hospitals, and data centers. By implementing intelligent variable speed control, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries significantly reduces energy consumption and mechanical stress on ventilation systems. Its design prioritizes ease of integration and long-term reliability, ensuring that critical climate control processes remain operational while achieving a best-case efficiency of 96.8%.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-101P22KT4E20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis tailored for high-density power management within an IP20 (H7 enclosure) footprint.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Profile:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for 22.0 kW applications, supporting a continuous output current of 88.0 A at 40 deg C ambient temperatures, ensuring stable operation under full-load HVAC cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Intelligence:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe drive features advanced thermal management, maintaining a continuous output of 79.2 A even at elevated ambient temperatures of 50 deg C, making it suitable for mechanical rooms with limited ventilation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Energy Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a typical power loss of only 804 W and an efficiency rating of 96.8%, the drive minimizes heat dissipation within the control cabinet, reducing the requirement for auxiliary cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe power terminals are designed to accommodate large-gauge cables up to 50 mm2 (1 AWG), allowing for secure, low-resistance connections essential for high-current industrial power distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-101P22KT4E20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShaft Output (kW)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.0 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShaft Output (hp)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.0 hp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ H7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase (380-480 VAC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Current (40 deg C)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e88.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Current (50 deg C)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e79.2 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Cable Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mm2 (1 AWG)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTypical Efficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e96.8%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e38.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the FC-101 drive handle motor cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-101P22KT4E20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports up to 50 meters of shielded motor cable or 75 meters of unshielded cable. If your HVAC installation requires longer runs, an output sine-wave filter or dU\/dt filter should be installed to prevent voltage spikes from reaching the motor windings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 22.0 kW rating affected by high ambient temperatures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the drive is rated for 88.0 A at 40 deg C, the continuous output drops to 79.2 A at 50 deg C. If the drive is installed in a high-temperature environment, ensure the motor's full-load current does not exceed the derated value.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Fire Mode\" feature in this HVAC drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFire Mode is a critical safety feature that allows the drive to ignore most internal protection alarms during an emergency, keeping smoke extraction fans running as long as possible to clear escape routes, regardless of damage to the drive itself.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting the 50 mm2 power cables, ensure the terminals are tightened to the manufacturer's specified torque. Loose connections at these high current levels (up to 88.0 A) will result in localized overheating and potential terminal block failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarmonic Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn large-scale HVAC projects, the cumulative effect of non-linear loads can distort the power grid. Utilize the drive’s built-in DC chokes to reduce harmonic interference (THDi), protecting sensitive electronics like PLC controllers and building management sensors on the same branch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet Airflow:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven the typical power loss of 804 W, the enclosure must have adequate forced ventilation. Position the drive vertically with at least 200 mm of free space above and below the H7 enclosure to facilitate natural convection and forced cooling airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418395499,"sku":"FC101P22KT4E20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fc101p22kt4e20-bwgi3qsyej4.png?v=1776137409"},{"product_id":"fc-051p2k2s2e20hxbxcxxxsxxx-danfoss-vlt-micro-drive-fc-51-variable-frequency-drive","title":"FC-051P2K2S2E20HXBXCXXXSXXX Danfoss VLT Micro Drive FC 51 Variable Frequency Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051P2K2S2E20HXBXCXXXSXXX (FC051P2K2S2E20HXBXCXXXSXXX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents a high-efficiency solution within the Danfoss VLT Micro Drive series, engineered for compact performance in demanding industrial environments. This 2.2 kW (3.0 HP) variable frequency drive (VFD) is specifically designed to optimize motor control in applications such as conveyor systems, pumping stations, and industrial fans. By integrating a built-in brake chopper and coated PCBs as standard, this unit ensures maximum uptime and reliability in harsh conditions characterized by moisture or dust. In critical sectors like food and beverage processing or warehouse automation, the FC 51 minimizes energy consumption while providing the precise torque control necessary to prevent mechanical wear and reduce unplanned downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFC-\u003c\/strong\u003e: VLT Micro Drive Product Group\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e051\u003c\/strong\u003e: Series 51\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP2K2\u003c\/strong\u003e: 2.2 kW \/ 3.0 HP Power Rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS\u003c\/strong\u003e: Single Phase input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2\u003c\/strong\u003e: 200 - 240 VAC Mains Voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20\u003c\/strong\u003e: IP20 \/ Chassis Enclosure rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHX\u003c\/strong\u003e: No RFI Filter included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB\u003c\/strong\u003e: Integrated Brake Chopper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e: No Local Control Panel (LCP) included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eC\u003c\/strong\u003e: Coated PCB for enhanced environmental protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e: No Mains Option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e: Standard Cable Entries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e: No Adaptation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSXXX\u003c\/strong\u003e: Latest standard software release\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-051P2K2S2E20HXBXCXXXSXXX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e136N8925\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark \/ China (Global Manufacturing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 kW (3.0 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 - 240 VAC (Single Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 deg C (with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced air cooling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 230 x 75 x 168 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure this drive if it is supplied without a Local Control Panel (LCP)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit can be programmed using an external LCP 11 or LCP 12 accessory. Alternatively, engineers can utilize the MCT 10 Setup Software via an RS485 interface to configure parameters, clone settings, and perform diagnostics from a PC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the benefits of the 'C' suffix (Coated PCB) in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe protective coating shields the internal electronics from aggressive gases, humidity, and airborne contaminants. This is critical for maintaining dielectric strength and preventing corrosion in environments like wastewater treatment or chemical processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an external braking resistor required for this specific unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince this model features a built-in brake chopper (B suffix), it can dissipate regenerative energy. However, an external braking resistor must be connected to the terminals if the application involves high-inertia loads or rapid deceleration cycles.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management \u0026amp; Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor IP20 chassis mounting, ensure a minimum of 100 mm clearance above and below the unit to allow for natural convection and forced air flow. These drives can be mounted side-by-side (bookstyle) without derating, significantly saving cabinet space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Compliance \u0026amp; Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSince this specific model (HX) does not include an internal RFI filter, you must use shielded motor cables and ensure 360-degree grounding at both the drive and motor ends to mitigate electromagnetic interference. Keep control wiring and power cables separated by at least 200 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrake Chopper Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting an external braking resistor, use twisted-pair cabling to reduce EMI. Ensure the resistor is mounted horizontally and away from heat-sensitive components, as surface temperatures can exceed 200 deg C during heavy braking cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418723179,"sku":"FC-051P2K2S2E20HXBXCXXXSXXX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fc-051p2k2s2e20hxbxcxxxsxxx-lssfjiubv54.png?v=1776137389"},{"product_id":"fc-051p7k5t4e20hxbxcxxxsxxx-danfoss-vlt-micro-drive-136n8935","title":"FC-051P7K5T4E20HXBXCXXXSXXX Danfoss VLT Micro Drive 136N8935","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136N8935 (136N8935)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact yet powerful VLT Micro Drive FC 51 designed for high-density industrial automation environments. Delivering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e7.5 kW (10 HP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof power in a remarkably small footprint, this frequency converter is engineered for side-by-side mounting in control cabinets to save significant panel space. It is particularly effective for controlling conveyor belts, mixers, and fan systems in manufacturing plants and assembly lines. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136N8935\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCoated PCBs (C)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas standard, providing enhanced durability against dust and moisture, ensuring consistent performance and reduced maintenance costs in typical industrial \"gray\" areas.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051P7K5T4E20HXBXCXXXSXXX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutlines the specific functional parameters of this Micro Drive:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFC-051\u003c\/strong\u003e: Part of the VLT Micro Drive series, optimized for efficiency and ease of use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP7K5\u003c\/strong\u003e: Power rating of 7.5 kW (10 HP), suitable for moderate-to-high torque applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT4\u003c\/strong\u003e: Designed for three-phase mains input ranging from 380 - 480 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20\u003c\/strong\u003e: IP20\/Chassis rating, intended for installation within a protected enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHX\u003c\/strong\u003e: No integrated RFI filter, ideal for isolated grids or environments where external filtering is already present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB\u003c\/strong\u003e: Integrated Brake Chopper, allowing the drive to manage regenerative energy during rapid motor deceleration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eC\u003c\/strong\u003e: Coated printed circuit boards for protection against environmental contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e136N8935\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 kW (10 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 - 480 VAC (Three Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrake Chopper\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (Built-in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCB Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEfficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e98%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 deg C (with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.075 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I program the drive if it is supplied without an LCP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 136N8935 (X version) does not include a Local Control Panel. You can program the drive using an external LCP 11 or LCP 12 accessory, or via a PC connection using the MCT 10 Set-up Software. Once programmed, the LCP can be removed for secure operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an external brake resistor required for this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause this unit includes a built-in brake chopper (\u003cstrong\u003eB\u003c\/strong\u003e), it can manage braking energy. However, for applications involving high inertia or frequent stops, you must connect an external brake resistor to the terminals to safely dissipate the heat generated during deceleration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the environmental limitations of the HX (No RFI Filter) version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe HX version is best suited for industrial environments where electromagnetic interference (EMI) limits are less stringent or where central plant-level filtering is installed. If used in residential or commercial zones, an external RFI filter may be required to meet local EMC regulations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSide-by-Side Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe VLT Micro Drive series is designed for \"true\" side-by-side mounting. You can install multiple units without any horizontal gap, which maximizes cabinet density. However, ensure a minimum of 100 mm vertical clearance above and below each unit to allow for natural convection and forced air cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrake Resistor Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting an external brake resistor, ensure the wiring is heat-resistant. Place the resistor in a location where its heat dissipation will not affect the drive's air intake or sensitive control wiring. Use a thermal switch to monitor resistor temperature and interlock it with the drive's enable signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding for Non-RFI Models:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSince this model lacks an internal RFI filter, proper grounding is even more critical. Use a short, thick, flat braided earth strap for the PE (Protective Earth) connection to provide a low-impedance path for high-frequency noise, protecting adjacent sensors and communication equipment from interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418755947,"sku":"FC-051P7K5T4E20HXBXCXXXSXXX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fc-051p7k5t4e20hxbxcxxxsxxx-fjv5nd5a3ua.png?v=1776137394"},{"product_id":"fc-102p1k5t4e20-danfoss-vlt-hvac-drive-131f0027","title":"FC-102P1K5T4E20 Danfoss VLT HVAC Drive 131F0027","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131F0027 (131F0027)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency VLT HVAC Drive engineered for precise motor control in automated building systems and industrial climate processes. This frequency converter, part of the specialized FC 102 series, delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.5 kW (2.0 HP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof power, making it an ideal choice for fan and pump applications in refineries, pharmaceutical cleanrooms, and power generation facilities. By optimizing the speed of three-phase motors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131F0027\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reduces energy consumption and mechanical stress. Its robust design ensures continuous operation in mission-critical environments, providing the reliability necessary to prevent unplanned downtime in complex B2B infrastructure.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-102P1K5T4E20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edenotes a specific hardware configuration tailored for industrial HVAC requirements:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFC\u003c\/strong\u003e: VLT Product Group identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e102\u003c\/strong\u003e: Specialized series for HVAC, including fans, pumps, and compressors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP1K5\u003c\/strong\u003e: 1.5 kW (2.0 HP) power rating for low-to-medium torque applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT\u003c\/strong\u003e: Optimized for three-phase input and output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4\u003c\/strong\u003e: Designed for standard 380 - 480 VAC mains voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20\u003c\/strong\u003e: IP20 enclosure rating, requiring installation within a protective control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e131F0027\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kW (2.0 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 - 480 VAC (Three Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Group\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVLT HVAC Drive FC 102\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Principle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVVC plus (Voltage Vector Control)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 45 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.9 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 131F0027 include an integrated RFI filter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the FC 102 series typically includes built-in RFI filters and DC link reactors to minimize electromagnetic interference and harmonic distortion, ensuring compliance with industrial EMC standards without external components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check if the drive reports a \"Mains Phase Loss\" fault?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect the input power terminals for loose connections and verify that all three phases of the 380 - 480 VAC supply are balanced. This fault often triggers to protect the DC link capacitors from excessive ripple current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for outdoor installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, with an E20 (IP20) rating, this unit is not weather-resistant. It must be installed in a climate-controlled or protected enclosure that prevents the ingress of dust, moisture, and conductive contaminants.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Clearance \u0026amp; Cooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain optimal thermal performance, install the drive vertically. Leave a minimum of 100 mm free space above and below the unit. This ensures the forced air cooling system can effectively dissipate heat from the internal power modules, preventing premature aging of the electrolytic capacitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways use shielded motor cables to prevent high-frequency noise from affecting sensitive sensors or communication lines in the cabinet. The shield should be terminated to the drive's decoupling plate using a metal clamp to provide a 360-degree low-impedance path to ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafe Torque Off (STO) Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf using the safety functions, ensure that the STO wiring is physically separated from the main power leads. Use twisted-pair cables for signal integrity and perform a functional test of the safety circuit during commissioning to verify the drive correctly disables the power output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419247467,"sku":"131F0027","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131f0027-0lmovbkpy3g.png?v=1776137004"},{"product_id":"131f1238-danfoss-vlt-hvac-drive-fc-102p3k0t4e20","title":"131F1238 Danfoss VLT HVAC Drive FC-102P3K0T4E20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131F1238 (131F1238)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance VLT HVAC Drive designed specifically for industrial climate control systems. Engineered by Danfoss, this frequency converter provides optimized motor control for fans, pumps, and compressors in demanding environments such as power plants, chemical processing facilities, and large-scale manufacturing hubs. With a power rating of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3.0 kW (4.0 HP)\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131F1238\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efocuses on reducing energy consumption and mechanical wear through precise speed regulation. Its integration into building management systems (BMS) ensures maximum uptime and system stability, delivering the high reliability required for critical infrastructure automation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-102P3K0T4E20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a specific functional logic:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFC\u003c\/strong\u003e: Identifies the VLT product group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e102\u003c\/strong\u003e: Specifies the HVAC-optimized drive series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP3K0\u003c\/strong\u003e: Represents the power rating of 3.0 kW (4.0 HP).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT\u003c\/strong\u003e: Indicates compatibility with three-phase power systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4\u003c\/strong\u003e: Denotes a mains voltage range of 380 - 480 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20\u003c\/strong\u003e: Signifies an IP20 enclosure rating, suitable for installation within protected control cabinets or cleanroom environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e131F1238\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kW (4.0 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 - 480 VAC (Three Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Group\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVLT HVAC Drive FC 102\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 45 deg C (at full load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air Cooling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.9 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 131F1238 be used in high-vibration industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the IP20 rating is designed for cabinet mounting, the VLT series is tested for industrial-grade vibration resistance. However, for extreme vibration, ensure the control cabinet utilizes proper shock absorption mounts to prevent mechanical stress on the internal PCB components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this drive handle harmonic distortion in power plant grids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC 102 series includes integrated DC link reactors as standard. This significantly reduces harmonic interference on the mains supply, meeting stringent EMC requirements without the need for additional external filters in most applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the procedure if the drive displays an Overvoltage Trip?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the mains voltage for surges or investigate if the motor is being driven by the load (regenerative energy). If the ramp-down time is too short for the inertia of the fan or pump, increase the deceleration time in the drive settings to stabilize the DC link voltage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven the IP20 rating, this drive must be installed in a ventilated enclosure. Maintain a minimum clearance of 100 mm above and below the unit to allow for unrestricted airflow from the internal cooling fans. If multiple units are mounted side-by-side, ensure the cabinet's total heat load does not cause the ambient temperature to exceed 45 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Correct Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo minimize electromagnetic interference, use shielded motor cables and ensure the shield has a 360-degree contact with the metal decoupling plate. Keep control wiring and high-power motor cables separated by at least 200 mm to prevent signal noise in the analog I\/O loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the drive is connected to a low-impedance ground. The PE (Protective Earth) connection must be established before applying power. For industrial automation systems with high-frequency noise, a flat braided copper strap is recommended for the ground connection to provide better performance than a standard round wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419280235,"sku":"131F1238","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131f1238-vs2wlhpt2wa.png?v=1776137005"},{"product_id":"danfoss-vlt-hvac-drive-fc-102p5k5t4e20-5-5kw","title":"Danfoss VLT HVAC Drive FC-102P5K5T4E20 5.5kW","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFC-102P5K5T4E20 (131B4220)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a premier VLT® HVAC Drive FC 102 series frequency converter,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003especifically engineered by Danfoss to provide advanced control and maximum energy savings for high-end building automation systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDelivering 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 kW (7.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 HP) of power,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis drive is the industry standard for managing sophisticated fan,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epump,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand chiller applications.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFC-102P5K5T4E20\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edistinguishes itself from basic drives through its intelligent HVAC features,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding a built-in Smart Logic Controller,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emultiple PID loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand an intuitive user interface.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy precisely matching motor speed to actual demand,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit significantly reduces energy consumption and mechanical stress,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring the longevity of critical HVAC infrastructure in hospitals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edata centers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand commercial complexes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe VLT® HVAC Drive FC 102 platform is designed for seamless integration into modern smart buildings.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis unit operates on a three-phase 380 - 480 VAC mains supply and is housed in a compact IP20 enclosure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoptimized for high-density mounting within control cabinets.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e131B4220\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis built with high-quality internal DC link reactors to minimize harmonic distortion without the need for external filters.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts hardware architecture supports a wide range of I\/O configurations and high-speed communication protocols.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eA key functional advantage is the drive's ability to operate in \"Sleep Mode,\u003c\/span\u003e\u003cspan class=\"\"\u003e\" which automatically detects low-flow conditions and shuts down the motor to conserve power,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhile remaining ready to restart instantly upon demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-102P5K5T4E20 (131B4220)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 kW \/ 7.5 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase 380 - 480 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDrive Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC 102 (Advanced HVAC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 98%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in BACnet, Modbus RTU, FC Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.54 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat makes the FC 102 series different from the FC 101 basic series?\u003c\/strong\u003e\u003cspan class=\"\"\u003eWhile both control HVAC motors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFC-102P5K5T4E20\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffers a much deeper feature set,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding more advanced PID control (up to 4 internal loops),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenhanced diagnostic tools,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand higher modularity for fieldbus options.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe FC 102 is designed for \"Total Building Control\" rather than simple motor speed adjustment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan this drive help in detecting a broken fan belt?\u003c\/strong\u003e\u003cspan class=\"\"\u003eYes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe FC 102 includes an \"End-of-Curve\" and \"Broken Belt\" detection feature.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy monitoring the relationship between power consumption and speed,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e131B4220\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecan trigger an alarm or stop the motor if it detects a sudden drop in load,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epreventing unnecessary energy waste and mechanical damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"animating\"\u003e\u003cstrong class=\"\"\u003eIs it possible to use this 5.5 kW drive on a 230 V network?\u003c\/strong\u003e\u003cspan class=\"\"\u003eNo.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specific model is configured with \"Mains Voltage 4,\u003c\/span\u003e\u003cspan\u003e\" which is strictly for 380 - 480 VAC three-phase supplies.\u003c\/span\u003e\u003cspan\u003e Attempting to power it with 230 V will result in an undervoltage trip,\u003c\/span\u003e\u003cspan\u003e and connection to higher voltages may cause permanent damage to the internal bridge rectifier.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Cooling:\u003c\/strong\u003e\u003cspan\u003e The FC 102 series utilizes back-channel cooling to dissipate heat efficiently.\u003c\/span\u003e\u003cspan\u003e For the IP20 chassis,\u003c\/span\u003e\u003cspan\u003e ensure a vertical clearance of at least 100 mm above and below the 6.\u003c\/span\u003e\u003cspan\u003e54 kg unit.\u003c\/span\u003e\u003cspan\u003e Avoid mounting the drive directly above heat-producing components like large contactors or power supplies.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBMS Integration:\u003c\/strong\u003e\u003cspan\u003e When connecting the drive to a BACnet or Modbus network,\u003c\/span\u003e\u003cspan\u003e use high-quality twisted-pair shielded cable.\u003c\/span\u003e\u003cspan\u003e Ensure the drive is correctly addressed in the software to allow the Building Management System (BMS) to access the drive's energy meters and diagnostic registers for centralized reporting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Best Practices:\u003c\/strong\u003e\u003cspan\u003e To maintain the drive's low-noise profile,\u003c\/span\u003e\u003cspan\u003e ensure the motor cable is shielded and that the shield is properly grounded at the drive's metal decoupling plate.\u003c\/span\u003e\u003cspan\u003e Keep control signal wires (0-10V or 4-20mA) separate from power cables to prevent electromagnetic interference from causing speed fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419313003,"sku":"131B4220","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131b4220-kfj1gpg3huz.png?v=1776137003"},{"product_id":"danfoss-vlt-micro-drive-fc-051p4k0t4e20hxbxc-4kw","title":"Danfoss VLT Micro Drive FC-051P4K0T4E20HXBXC 4kW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051P4K0T4E20HXBXCXXXSXXX (136N8931)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rugged and highly efficient VLT® Micro Drive FC 51 designed by Danfoss to provide high-density motor control in a compact chassis. Delivering 4.0 kW (5.0 HP) of power, this frequency converter is optimized for simple automation tasks where reliability is paramount but space is limited, such as in conveyor systems, fan units, and industrial pumps. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051P4K0T4E20HXBXCXXXSXXX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a cost-effective solution that does not sacrifice durability, featuring factory-coated PCBs for protection against moisture and dust. Its integrated brake chopper allows for precision control over decelerating loads, making it an ideal choice for machinery requiring rapid stop cycles or controlled descent.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe VLT® Micro Drive platform is engineered for maximum versatility with a minimal footprint. This specific 4.0 kW variant operates on a three-phase 380 - 480 VAC supply. A key characteristic of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136N8931\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the \"HX\" configuration, meaning it is supplied\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewithout an RFI filter\u003c\/strong\u003e, making it suitable for IT mains (isolated terrestrial networks) or applications where external filtering is already provided. The drive includes a built-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrake Chopper (B Option)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto dissipate regenerative energy through an external resistor. Furthermore, the \"C\" option indicates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCoated PCBs\u003c\/strong\u003e, providing enhanced protection for the internal electronics in environments with high humidity or airborne contaminants, ensuring a longer service life compared to non-coated alternatives.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-051P4K0T4E20HXBXC (136N8931)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kW \/ 5.0 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase 380 - 480 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHX (No RFI Filter)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrake Chopper\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated (Option B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoated (Option C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLatest Standard Release (SXXX)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy would I choose a drive without an RFI filter (HX)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDrives without internal RFI filters are primarily used on IT grids (isolated networks) where a filter to ground could cause insulation monitoring issues. Additionally, if you are installing the drive in a system that already utilizes a large central RFI filter at the cabinet entry, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136N8931\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a more economical solution by avoiding redundant filtering components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Coated PCB benefit my facility?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCoated PCBs protect the sensitive surface-mount components from \"Pollution Degree 3\" conditions, which include non-conductive dust and high humidity. This is essential for maintaining the 4.0 kW output performance in industrial environments like wood processing, textiles, or food and beverage packaging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I operate this drive without an LCP (Local Control Panel)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While this unit is shipped without an LCP (Code X), the drive can be commissioned via the RS485 port using a PC and the Danfoss MCT 10 Set-up Software. For manual on-site control, a plug-in LCP 11 or LCP 12 can be purchased separately and used across multiple Micro Drive units.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrake Resistor Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo utilize the integrated brake chopper for rapid braking, connect a suitable external brake resistor to terminals +BR and -BR. Ensure the resistor is mounted outside the drive enclosure or in a well-ventilated area, as it will generate significant heat during motor deceleration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause this unit lacks an internal RFI filter, it is critical to ensure that cable routing for the 380 - 480 VAC mains and the motor lines follows strict EMC guidelines if the system is installed near sensitive electronics. Use shielded motor cables to minimize radiated interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSide-by-Side Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC 51 series is designed for side-by-side mounting, meaning no horizontal clearance is required between drives in a control cabinet. However, ensure at least 100 mm of vertical clearance above and below the 3.0 kg unit to allow for unimpeded cooling airflow through the heatsink.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419509611,"sku":"FC-051P4K0T4E20HXBXCXXXSXXX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fc-051p4k0t4e20hxbxcxxxsxxx-jfai5y2h0ff.png?v=1776137392"},{"product_id":"danfoss-vlt-automationdrive-fc-302p5k5t5e20h2xgc-5-5kw","title":"Danfoss VLT AutomationDrive FC-302P5K5T5E20H2XGC 5.5kW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P5K5T5E20H2XGC (131B0151)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance VLT® AutomationDrive FC 302 series frequency inverter, specifically engineered by Danfoss for advanced industrial motor control applications. Delivering 5.5 kW (7.5 HP) of power, this drive is designed for high-torque tasks such as heavy-duty conveyors, precision positioning systems, and industrial mixers. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P5K5T5E20H2XGC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out for its extreme reliability, featuring factory-coated PCBs for protection against harsh environments and an integrated Graphical Local Control Panel (LCP) for intuitive onsite monitoring and programming. Its sophisticated control logic allows for seamless integration into complex automated systems, providing the high-speed response and motor shaft performance required in modern smart factories.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe VLT® AutomationDrive FC 302 platform is a modular, future-ready solution built for the most demanding technical requirements. This specific configuration operates on a wide three-phase mains voltage of 380 - 500 V and includes an H2 RFI filter for superior electromagnetic compatibility (EMC). A critical feature of this model is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"C\" Option (Coated PCB)\u003c\/strong\u003e, which provides an extra layer of protection against moisture, dust, and corrosive chemicals, significantly extending the drive's service life in industrial settings. The inclusion of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGraphical LCP (G)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for full-text parameter access and real-time performance graphing, facilitating rapid troubleshooting and commissioning without the need for an external PC.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-302P5K5T5E20H2XGC (131B0151)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 kW \/ 7.5 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase 380 - 500 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree Phase (T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH2 (RFI Filter)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoated (C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGraphical LCP Included (G)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrake Chopper\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (X)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.05 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Coated PCB (C option) benefit my industrial application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn environments such as wastewater treatment, chemical processing, or textiles, airborne contaminants can cause conductive tracks on circuit boards to short-circuit. The coating on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131B0151\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecreates a chemical-resistant barrier, ensuring the drive remains operational where standard drives might fail due to \"pollution degree 3\" conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the Graphical LCP be used to copy parameters to other drives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The Graphical LCP (G) features a built-in memory function. You can save a complete parameter set from one 5.5 kW FC-302 and \"upload\" it to another drive of the same series, significantly reducing commissioning time for multi-drive systems or during maintenance replacements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for high-inertia loads that require fast braking?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific model (Code X) does not include a built-in brake chopper. For applications requiring rapid deceleration of heavy loads, you would either need a variant with an integrated brake chopper or implement an external regenerative unit to manage excess energy and prevent DC-link overvoltage trips.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Compliance \u0026amp; Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure the H2 RFI filter functions correctly, use a shielded motor cable. The shield must be terminated at both ends—using a 360-degree HF clamp at the drive's metal decoupling plate and a proper gland at the motor terminal box. This minimizes high-frequency noise that could interfere with sensitive control signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC 302 relies on its internal fans for cooling. For the IP20 chassis, ensure a minimum of 100 mm clearance above and below the unit for vertical airflow. Monitor the cabinet temperature to ensure it stays within the -10 to 45 deg C range to maintain the full 5.5 kW output without thermal derating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the digital and analog inputs to maximize the drive's built-in Smart Logic Controller. For long cable runs for the analog reference (0-10V or 4-20mA), use twisted-pair shielded cables and keep them at least 200 mm away from power cables to avoid signal corruption that could lead to speed instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419575147,"sku":"131B0151","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131b0151-z51wipke5sj.png?v=1776137000"},{"product_id":"danfoss-vlt-hvac-basic-drive-fc-101p7k5t4e20h4","title":"Danfoss VLT HVAC Basic Drive FC-101P7K5T4E20H4","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131L9868 (131L9868)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency VLT® HVAC Basic Drive FC-101, specifically engineered by Danfoss to meet the rigorous demands of heating, ventilation, and air conditioning systems. Delivering a robust 7.5 kW (10 HP) of power, this frequency converter is the ideal solution for optimizing fan and pump performance in commercial and industrial building automation. By utilizing advanced variable speed control, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-101P7K5T4E20H4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reduces energy consumption and mechanical wear on motor-driven systems. Its compact IP20 enclosure is designed for cabinet mounting, providing a cost-effective, \"fit-and-forget\" solution that enhances system reliability and reduces the total cost of ownership for HVAC infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FC-101 series is built on a streamlined hardware platform that prioritizes ease of installation and high energy efficiency. This unit operates on a three-phase 380 - 480 VAC mains supply and includes a built-in H4 RFI filter (Class A1\/C2), ensuring compliance with electromagnetic compatibility standards in most industrial and commercial environments. The drive features an integrated HVAC-specific software suite, including a built-in PID controller for pressure and flow regulation, as well as a specialized \"Fire Mode\" for safety-critical smoke extraction fans. The 4.9 kg lightweight chassis is optimized for DIN rail or backplate mounting, and its modular design allows for rapid parameter setup using the local control panel or PC-based software.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-101P7K5T4E20H4 (131L9868)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 kW \/ 10 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase 380 - 480 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH4 (Class A1\/C2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree Phase (T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 98%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 40 deg C (Full load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.9 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive support communication protocols common in HVAC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FC-101 series comes standard with built-in FC Protocol, Modbus RTU, and BACnet (MS\/TP). This allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131L9868\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto integrate seamlessly into Building Management Systems (BMS) for remote monitoring and centralized control of 7.5 kW motor loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the H4 RFI filter in a commercial building?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe H4 (Class A1\/C2) filter minimizes electromagnetic interference generated by the drive. This is critical in commercial settings to prevent the drive from disrupting sensitive electronics, communication lines, or office equipment sharing the same power grid.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 131L9868 be used with permanent magnet (PM) motors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VLT® HVAC Basic Drive is primarily optimized for standard induction motors. While it provides excellent control for asynchronous motors, users requiring high-performance PM motor control should verify compatibility with the specific firmware version (SXXX) or consider the FC-102 series for advanced motor motor technology support.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAirflow Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-101 relies on vertical convection for cooling. Ensure a minimum of 100 mm clearance above and below the drive. Since this model is IP20, it must be installed in a clean, dry cabinet where the ambient temperature does not exceed 40 deg C to maintain the 7.5 kW power rating without derating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFire Mode Implementation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the Fire Mode for life-safety applications, ensure the control logic is wired to a dedicated digital input. Note that when Fire Mode is active, the drive will ignore most internal protective trips to keep the fan running as long as possible; therefore, periodic testing of this loop is essential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain RFI Class A1 compliance, use shielded motor cables. The shield should be terminated with a 360-degree HF clamp at the drive's metal decoupling plate. Avoid \"pigtail\" grounding of the shield, as this creates high-frequency impedance and reduces the effectiveness of the H4 filter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419673451,"sku":"131L9868","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131l9868-0fnkjojdnbh.png?v=1776137020"},{"product_id":"danfoss-vlt-micro-drive-fc-051p4k0t4e-4kw","title":"Danfoss VLT Micro Drive FC-051P4K0T4E 4kW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e132F0026 (132F0026)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a highly compact and efficient VLT® Micro Drive FC-051, engineered by Danfoss to provide maximum reliability and ease of use in general-purpose motor control applications. Delivering 4.0 kW (5.5 HP) of power, this three-phase frequency converter is optimized for industrial machinery such as conveyors, pumps, and fans where cabinet space is at a premium. Despite its small footprint, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051P4K0T4E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built with heavy-duty components, including coated PCBs and a built-in brake chopper, ensuring high performance and longevity even in demanding environments. Its sophisticated VVC+ control logic provides excellent motor shaft performance, significantly improving process precision and reducing energy waste across the automation lifecycle.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe VLT® Micro Drive platform is designed for side-by-side mounting without derating, maximizing panel density. This specific unit operates on a 380 - 480 VAC supply and features an H3 RFI filter, providing high-level electromagnetic compatibility (Class A1\/B). A critical hardware advantage is the factory-integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrake Chopper\u003c\/strong\u003e, which allows the drive to manage regenerative energy during rapid motor deceleration, protecting the DC link from overvoltage. The inclusion of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCoated PCBs (C Option)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides an essential layer of protection against moisture and airborne contaminants, making the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e132F0026\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ea superior choice for industrial settings. The drive supports up to 5 programmable digital inputs and dual analog inputs, allowing for versatile control configurations directly from the terminal block.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-051P4K0T4E (132F0026)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kW \/ 5.5 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase 380 - 480 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 200 Hz (VVC+) \/ 0 - 400 Hz (U\/f)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH3 (Class A1\/B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrake Chopper\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated (Option B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e194 x 90 x 239 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 132F0026 include a local control panel (LCP)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific code is supplied without an LCP (indicated by the 'X'). For manual operation or local parameter adjustment, a VLT® Control Panel LCP 11 (without potentiometer) or LCP 12 (with potentiometer) must be ordered separately and plugged into the front interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the VVC+ control mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVVC+ (Voltage Vector Control Plus) is a Danfoss-patented control principle that ensures the motor develops full torque at low speeds and responds rapidly to load changes. It provides near-servo performance for standard induction motors, enhancing the efficiency of the 4.0 kW output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be mounted horizontally?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor optimal cooling, the drive must be mounted vertically. The IP20 enclosure relies on natural or forced convection through the heatsink. Vertical mounting ensures that the 194 mm height of the unit acts as a chimney, pulling cool air from the bottom and exhausting heat from the top.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrake Resistor Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSince this unit features a built-in brake chopper, you can connect an external brake resistor to the BR+ and BR- terminals for applications requiring fast braking or frequent stops. Ensure the resistor value (Ohms) matches the drive’s 4 kW specifications to avoid damaging the internal chopper circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePCB Protection \u0026amp; Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe coated PCBs in this model offer enhanced resistance to pollution degree 3 environments. However, ensure that the cabinet ventilation is filtered to prevent the buildup of conductive dust on the terminal blocks, which are not coated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum distance of 200 mm between the motor cable and the control\/signal cables to prevent electromagnetic crosstalk. Use shielded motor cables and ensure the shield is connected to the ground plate at the drive end using a high-frequency (HF) clamp to comply with the H3 RFI filter standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419706219,"sku":"132F0026","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/132f0026-avtghs2s0np.png?v=1776137035"},{"product_id":"danfoss-vlt-fc-302p7k5t5e20h2-automationdrive","title":"Danfoss VLT FC-302P7K5T5E20H2 AutomationDrive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P7K5T5E20H2XXXXXXSXXXXA0BXCXXXXD0 (131B0689)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance VLT® AutomationDrive FC-302 engineered by Danfoss for advanced industrial motor control. Delivering 7.5 kW (10 HP) of power, this three-phase inverter is optimized for complex automation tasks in sectors such as automotive assembly, high-speed packaging, and chemical processing. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P7K5T5E20H2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a specialized hardware configuration including a PROFIBUS DP MCA 101 interface and an MCB-107 24V DC backup module, ensuring seamless integration into high-level fieldbus networks and maintaining control logic during primary power loss. Its rugged A3 frame size and intelligent thermal management significantly reduce heat-related failures, maximizing system uptime in demanding production environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe VLT® AutomationDrive FC-302 is built on a modular platform designed for maximum flexibility. This specific unit is configured for 380 - 500 VAC mains voltage and housed in an IP20\/Chassis enclosure, suitable for installation within protected control cabinets. While this variant utilizes an H2 RFI filter for electromagnetic compatibility, it is designed for standard environments with non-coated PCBs. A critical functional enhancement included in this model is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eD Option (MCB-107)\u003c\/strong\u003e, which provides 24V DC backup power to the control card, allowing fieldbus communication and encoder positions to remain active even when the 400V mains power is disconnected for safety or maintenance. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA Option (MCA 101)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadds high-speed PROFIBUS DP connectivity, enabling real-time diagnostic feedback and precision speed control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-302 \/ 131B0689\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 kW \/ 10 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase 380 - 500 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DP (MCA 101)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Backup\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMCB-107 24V DC Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH2 Class\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the MCB-107 24V DC backup benefit the system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MCB-107 module allows the drive's control circuit and communication options (like PROFIBUS) to remain powered from an external 24V source. This ensures the PLC does not lose contact with the drive during a mains power cycle, preventing \"node failure\" alarms and allowing for faster system recovery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used in high-humidity environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features \"X\" for PCB coating, meaning the boards are not coated. For environments with high humidity or corrosive gases, it is recommended to specify a \"C\" version (3C3 coating) to ensure long-term reliability of the internal electronics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable length supported for the motor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the H2 RFI filter in an A3 frame, the FC-302 typically supports up to 150 meters of shielded motor cable or 300 meters of unshielded cable while maintaining performance. However, for strict EMC compliance, always refer to the specific Danfoss installation manual for the A3 frame size.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarmonic Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-302 includes integrated DC link reactors that reduce harmonic distortion to below 40-45% THDi. To further optimize power quality in facilities with many 7.5 kW drives, ensure that the mains supply is balanced and consider an upstream active filter if the total harmonic load exceeds 5% of the transformer capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProfibus Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen wiring the MCA 101 PROFIBUS option, ensure that the physical termination switch is set to \"ON\" only at the first and last nodes of the network segment. Use high-quality purple PROFIBUS cable and keep signal lines at least 200 mm away from motor power cables to prevent data corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting \u0026amp; Cooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe A3 frame requires a minimum of 100 mm clearance above and below the unit for vertical airflow. Since this is an IP20 chassis, ensure the cabinet fan capacity (m3\/h) exceeds the total heat dissipation of all drives within the enclosure to prevent thermal tripping during peak 10 HP loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419902827,"sku":"FC-302P7K5T5E20H2XXXXXXSXXXXA0BXCXXXXD0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fc-302p7k5t5e20h2xxxxxxsxxxxa0bxcxxxxd0-gcleg2ekkid.png?v=1776137405"}],"url":"https:\/\/www.plcprotech.com\/collections\/danfoss-vlt-inverters.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}