{"title":"Foxboro","description":"\u003cp\u003eFoxboro, a premier brand of Schneider Electric, provides advanced Distributed Control Systems (DCS) and field instrumentation for the process industries. The system architecture, notably the Foxboro I\/A Series and EcoStruxure Foxboro DCS, utilizes high-performance FCP controllers and high-density FBM I\/O modules. Technical characteristics include high-speed mesh networking, object-oriented engineering, and field-proven sensor technology for pressure and flow measurement. Functionally, Foxboro solutions manage continuous process control in refineries, chemical plants, and pulp and paper mills. By integrating seamlessly with \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/schneider-electric\"\u003eSchneider Electric’s\u003c\/a\u003e software suite, Foxboro hardware ensures precise process regulation and enhanced asset reliability across the complete industrial lifecycle.\u003c\/p\u003e","products":[{"product_id":"foxboro-fbm214-i-a-series-hart-communication-input-interface-module","title":"Foxboro FBM214 I\/A Series HART Communication Input Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Foxboro \u003cstrong\u003eFBM214\u003c\/strong\u003e is an analog\/HART input module designed for process control and interface applications within the I\/A Series system. The \u003cstrong\u003eFBM214\u003c\/strong\u003e contains eight group-isolated analog input channels, each supporting either a standard 4 to 20 mA analog signal or a digital HART Frequency Shift Keying (FSK) signal superimposed on a 4 to 20 mA analog input. Each channel features a dedicated FSK modem that enables bi-directional digital communication with connected HART field devices at 1200 baud. An integrated Sigma-Delta converter delivers 15-bit resolution and updates analog input values for all channels every 100 ms. The module serves as a HART communications field device host, handling point-to-point, master\/slave digital message transfers at a rate of 2 messages per second using HART Protocol v6. It interfaces with the redundant 2 Mbps module Fieldbus and provides a common isolated 24 V dc internal power supply for loop-powered devices, with options for external power configurations using a Cable Balun module.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight group-isolated input channels accepting standard 4 to 20 mA or superimposed digital HART FSK signals.\u003c\/li\u003e\n\u003cli\u003eDedicated FSK modem per input channel for bi-directional digital communications with HART devices.\u003c\/li\u003e\n\u003cli\u003eOnboard Sigma-Delta analog-to-digital converter providing 15-bit resolution and a 100 ms update rate per channel.\u003c\/li\u003e\n\u003cli\u003eGalvanic group isolation of all 8 input channels from ground and module logic.\u003c\/li\u003e\n\u003cli\u003eSupport for HART Protocol v6 master\/slave communication at 1200 baud with asynchronous, half-duplex transmission.\u003c\/li\u003e\n\u003cli\u003eDual communication capability over redundant 2 Mbps Fieldbus path A and path B.\u003c\/li\u003e\n\u003cli\u003eIntegrated isolated 24 V dc power supply for powering field transmitters across all channels.\u003c\/li\u003e\n\u003cli\u003eCompact, rugged extruded aluminum housing designed for mounting in Class G3 harsh environments.\u003c\/li\u003e\n\u003cli\u003eFront panel Light-Emitting Diodes (LEDs) for visual monitoring of operational status and channel communication activity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterface for HART-enabled field transmitters (temperature, pressure, flow, level).\u003c\/li\u003e\n\u003cli\u003eProcess control monitoring requiring high-accuracy 4 to 20 mA analog input acquisition.\u003c\/li\u003e\n\u003cli\u003eDistributed control system integration via redundant 2 Mbps Fieldbus networks.\u003c\/li\u003e\n\u003cli\u003eHazardous area field wiring connections utilizing associated apparatus and non-incendive circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0922VT\u003c\/td\u003e\n\u003ctd\u003eFBM214 HART Communication Input Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0903SV\u003c\/td\u003e\n\u003ctd\u003eCBM-4 Cable Balun Module (4 Baluns)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0916BX\u003c\/td\u003e\n\u003ctd\u003eTermination Assembly, PVC, Compression Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0926EA\u003c\/td\u003e\n\u003ctd\u003eTermination Assembly, Polyamide (PA), Compression Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0926TD\u003c\/td\u003e\n\u003ctd\u003eTermination Assembly, PVC, Ring Lug Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFoxboro \/ Invensys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFBM214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP0922VT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 group-isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHART Protocol v6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 4 to 20 mA analog; Digital HART FSK superimposed on 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 baud (HART field device); 2 messages\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSigma-Delta converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegration Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03% of full scale (includes nonlinearity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ppm\/degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Sense Resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61.9 Ω nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Input Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 Ω minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 db at 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Mode Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;35 db at 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 V dc minimum at 20.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Loop Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V dc ±10% common power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Input Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V dc ±5% (redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Heat Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Potential\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V ac applied for 1 minute between group-isolated channels and earth ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFieldbus Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundant 2 Mbps module Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Module)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 degC (-4 to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC (-40 to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-300 to +3,000 m (-1,000 to +10,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContamination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass G3 (Harsh) per ISA Standard S71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 m\/s2 (0.75 g) from 5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm x 45 mm x 104 mm (4 in x 1.75 in x 4.11 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight with Lugs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114 mm (4.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e284 g (10 oz) approximate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin \/ Terminal\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseplate Fieldbus Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundant 2 Mbps Fieldbus path A and path B connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseplate Power Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundant independent 24 V dc power connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseplate Field Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25-pin male D-subminiature connection to Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTA 3-Tier Terminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField wiring connections (compression screw or ring lug) for 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Mount the module onto a modular baseplate (4-slot or 8-slot options). The baseplate can be installed on a 32 mm or 35 mm DIN rail (horizontally\/vertically) or horizontally on a 19-inch rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring\u003c\/strong\u003e: Connect field signals using a DIN rail-mounted Termination Assembly (TA) connected via a Type 1 termination cable to the baseplate field connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Configurations\u003c\/strong\u003e: When using external power for two or more loops on a common supply, install a Cable Balun Module (CBM-4) in each loop to prevent crosstalk and maintain signal line balance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swapping\u003c\/strong\u003e: The module supports removal and replacement without disrupting field device cabling, power, or system communication cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration\u003c\/strong\u003e: Operational calibration of the module or its termination assembly is not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuropean EMC Directive 89\/336\/EEC\u003c\/strong\u003e: EN 50081-2 Emission, EN 50082-2 Immunity, EN 61326 Annex A (Industrial Levels), CISPR 11 Class A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Immunity Standards\u003c\/strong\u003e: IEC 61000-4-2 (ESD), IEC 61000-4-3 (Radiated Field), IEC 61000-4-4 (EFT\/Burst), IEC 61000-4-5 (Surge), IEC 61000-4-6 (Conducted), IEC 61000-4-8 (Magnetic Field).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL \/ UL-C Listing\u003c\/strong\u003e: Suitable for Class I, Groups A-D, Division 2, T4 enclosure systems; associated apparatus for non-incendive communication circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ CENELEC (DEMKO)\u003c\/strong\u003e: Certified EEx nA IIC T4 for use in Zone 2 potentially explosive atmospheres per Directive 94\/9\/EC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuropean Low Voltage Directive\u003c\/strong\u003e: 73\/23\/EEC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695386947947,"sku":"FBM214","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FBM214_001_1200x1200_761013df-a352-4b16-a6fd-bf05e134f465.jpg?v=1786613339"},{"product_id":"foxboro-p0973bp-redundant-power-supply-module-the-mesh-control-network","title":"Foxboro P0973BP Redundant Power Supply Module (The MESH Control Network)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0973BP\u003c\/strong\u003e is a high-reliability \u003cstrong\u003e156 Watt Redundant Power Supply (RPS)\u003c\/strong\u003e module specifically engineered for the \u003cstrong\u003eFoxboro Evo™\u003c\/strong\u003e and \u003cstrong\u003eI\/A Series®\u003c\/strong\u003e systems within \u003cstrong\u003eThe MESH Control Network\u003c\/strong\u003e architecture. Designed to eliminate the network switch as a single point of failure, this module operates in a parallel capacity with a switch’s internal power supply. In the event of an AC power loss or internal component failure, the \u003cstrong\u003eP0973BP\u003c\/strong\u003e instantaneously supports the full load, ensuring that critical process control traffic continues to flow without interruption or network reconvergence.\u003c\/p\u003e\n\u003ch3\u003eSystem Architecture \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eP0973BP\u003c\/strong\u003e is a modular component of the \u003cstrong\u003eThe MESH Control Network Ethernet Equipment\u003c\/strong\u003e catalog. It must be housed in a specialized Redundant Power Supply Chassis (\u003cstrong\u003eP0973BM\u003c\/strong\u003e or \u003cstrong\u003eP0973BN\u003c\/strong\u003e) and is verified to support a wide range of Foxboro managed switches:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA4-Series Switches:\u003c\/strong\u003e P0973JM (24-Port Copper), P0973JN (24-Port Fiber), and P0973JP (8-Port Combo).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB-Series \u0026amp; C-Series:\u003c\/strong\u003e P0973LK and P0973KJ high-performance Gigabit switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Options:\u003c\/strong\u003e * \u003cstrong\u003eP0973BN:\u003c\/strong\u003e Accommodates 2 RPS modules for up to 2 switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP0973BM:\u003c\/strong\u003e Accommodates up to 8 RPS modules for centralized high-density power redundancy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC Input Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85-264 V ac, 47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e102 W or 156 W continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5 to +40°C (41 to +104°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to +73°C (-22 to +164°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 90% (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.6 cm x 5.2 cm x 25.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMass (Approximate)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.75 kg (3.85 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContamination\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass G1 (Mild) as defined in ISA Standard S71.04\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is parallel capacity important for The MESH network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike \"cold standby\" power supplies that require a startup time, the \u003cstrong\u003eP0973BP\u003c\/strong\u003e works in parallel. This ensures there is no \"switch-over\" time. For \u003cstrong\u003eThe MESH Control Network\u003c\/strong\u003e, this prevents the Rapid Spanning Tree Protocol (RSTP) from having to re-converge due to a momentary switch power drop, maintaining 100% uptime for safety-critical logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the role of the RPS Chassis (P0973BM\/BN)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eP0973BP\u003c\/strong\u003e module does not have built-in AC electronics or power cords. The chassis provides the structural housing and the common AC backplane. This modularity allows an engineer to replace a single power module while the other switches in the same chassis remain powered and operational.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the G1 Contamination rating affect installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eClass G1 (Mild)\u003c\/strong\u003e rating indicates the module is designed for standard industrial control rooms. If the equipment is being installed in a more corrosive environment (e.g., near chemical processing units with high H2S levels), the module should be housed in a purged or environmentally controlled enclosure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Source Redundancy:\u003c\/strong\u003e For maximum availability, connect the RPS chassis to a different AC branch circuit or UPS than the primary internal power supply of the switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Hot-Swapping:\u003c\/strong\u003e The \u003cstrong\u003eP0973BP\u003c\/strong\u003e is hot-swappable. If a module failure is indicated, it can be pulled from the chassis and replaced without disturbing the network configuration or the power state of the connected switch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling Logic:\u003c\/strong\u003e Ensure the RPS cable is securely fastened to the DC input of the switch. Periodic inspections of the cable seating are recommended in environments subject to high vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eP0973BP\u003c\/strong\u003e is a fundamental component for achieving high-availability targets in \u003cstrong\u003eFoxboro Evo\u003c\/strong\u003e and \u003cstrong\u003eI\/A Series\u003c\/strong\u003e installations. By utilizing the \u003cstrong\u003eThe MESH\u003c\/strong\u003e-certified power infrastructure, plant operators ensure full regulatory compliance and safety certification (UL, CSA, IEC 60950). For B2B procurement, sourcing original \u003cstrong\u003eP0973BP\u003c\/strong\u003e modules guarantees that your network infrastructure aligns with the \u003cstrong\u003ePSS 31H-7C3 B4\u003c\/strong\u003e standard, providing the long-term reliability required for the world's most critical process industries.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695401234795,"sku":"P0973BP","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/foxboro-p0973bp-redundant-power-supply-module-grkcvvzumfu_a93f05b5-6f2c-4017-87eb-2ebd57f9bb35.jpg?v=1766133752"},{"product_id":"foxboro-p0922yu-fps400-24-standard-200-series-power-supply-module","title":"Foxboro P0922YU FPS400-24 Standard 200 Series Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-226\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-226\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-226\"\u003eP0922YU (P0922YU)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-226\"\u003e is a high-performance \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-226\"\u003eFPS400-24\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-226\"\u003e standard 200 Series power supply designed to provide reliable 24 VDC power to Foxboro Evo process automation subsystem baseplates\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-226 citation-end-226\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-225\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eDelivering a robust 400 W output, this module is engineered for mission-critical industrial environments such as oil refineries, power generation plants, and chemical processing facilities\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-225 citation-end-225\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-224\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eIts high-efficiency, convection-cooled design eliminates the need for mechanical fans, significantly reducing failure points and maintenance requirements in continuous process operations\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-224 citation-end-224\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-223\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-223\"\u003eBy ensuring stable power delivery to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-223\"\u003e200 Series FBMs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-223\"\u003e, the P0922YU plays a vital role in minimizing system downtime and maintaining control integrity\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-223 citation-end-223\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eP0922YU\u003c\/strong\u003e is distinguished by its wide-range universal input stage. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-222\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eUnlike the DC-only variants, this unit features an advanced input circuit that automatically accepts 120\/240 VAC (85 to 265 VAC) or 125 VDC (108 to 145 VDC)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-222 citation-end-222\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-221\"\u003eActive Power Factor Correction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-221\"\u003e For AC inputs, the module utilizes a sinusoidal current profile to achieve near-unity power factor, optimizing energy usage\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-221 citation-end-221\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-220\"\u003eSafety \u0026amp; Protection Layers:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-220\"\u003e The architecture includes dual-stage current limiting set at 110 percent of maximum load and overvoltage shutdown circuitry with a sub-30 second reset time\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-220 citation-end-220\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-219\"\u003eEnvironmental Hardening:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-219\"\u003e The unit features a G3 rating for harsh environments and a sealed, gasketed housing that protects sensitive electronics against corrosive gases like hydrogen sulfide and chlorine\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-219 citation-end-219\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eP0922YU\u003c\/strong\u003e (FPS400-24)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFoxboro by Schneider Electric\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240 VAC (85-265 VAC) or 125 VDC (108-145 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Factory set at 24.0 VDC +\/- 0.2 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 W (Subject to temperature derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 95 percent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to 71 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e215 x 178 x 107 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.67 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, UL-C, CENELEC Zone 2, Class 1 Div 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCan I use the P0922YU to power both baseplates and field devices simultaneously?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-217\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eWhile the FPS400-24 can power external field devices, it is a best practice for system integrity to avoid powering DIN rail baseplates and field devices from the same unit\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-217 citation-end-217\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat should I do if the Red LED indicator is illuminated?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-216\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe Red LED signifies an output undervoltage condition (less than 22 VDC)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-216 citation-end-216\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. You should check for overloads or input power fluctuations. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-215\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eIf an overvoltage shutdown has occurred, input power must be interrupted to reset the circuit\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-215 citation-end-215\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs this power supply compatible with older 200 Series cables?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-214\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eYes, the output power supply connector is designed to be compatible with both newer modular baseplate cables and older version cables used with P0914XA\/XB baseplates\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-214 citation-end-214\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes the unit require specific mounting orientations for cooling?\u003c\/strong\u003eThe unit is convection cooled. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-213\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eWhile it supports both horizontal and vertical DIN rail mounting, a DIN rail clamp (P\/N X0175TQ) must be used below the supply when mounted vertically to ensure stability\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-213 citation-end-213\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-212\"\u003eThermal Management:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-212\"\u003e To ensure proper convection cooling, maintain a minimum clearance of 76.2 mm (3 inches) at the top, bottom, and sides of the module\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-212 citation-end-212\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-211\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eConsult the temperature derating table if operating in ambient temperatures exceeding 25 deg C, as available wattage drops as temperature rises\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-211 citation-end-211\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-210\"\u003eWiring Safety:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-210\"\u003e Utilize special Foxboro-qualified cables for all connections to improve personal safety and simplify installation\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-210 citation-end-210\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-209\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eFor AC inputs, ensure the P0926DZ terminal block is correctly integrated with the RH923DA or equivalent cable\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-209 citation-end-209\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Integration:\u003c\/strong\u003e Leverage the Form C relay status alarm output for remote monitoring. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-208\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe relay de-energizes when output falls below 22 VDC, providing a reliable trigger for external alarm systems\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-208 citation-end-208\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-207\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-207\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-207\"\u003eP0922YU\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-207\"\u003e offers an exceptional Return on Investment (ROI) of less than two years, driven by its 95 percent efficiency rating which lowers electrical overhead and heat dissipation\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-207 citation-end-207\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-206\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eIts robust, fan-less design is purpose-built for the \"invisible\" infrastructure of a plant, providing 3000 VAC isolation between input and output to protect sensitive control logic from line-side transients\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-206 citation-end-206\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. The downward compatibility with various baseplate generations makes it an ideal choice for site expansions or lifecycle upgrades within the \u003cstrong\u003eFoxboro Evo\u003c\/strong\u003e ecosystem.\u003c\/span\u003e\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695401333099,"sku":"P0922YU FPS400-24","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/foxboro-p0922yu-fps400-24-controller-power-supply-module-vyfwdwhn1ck_fa9cf90c-1e6f-4498-9789-db99651cf067.jpg?v=1766133761"},{"product_id":"p0931rm-foxboro-i-a-series-redundant-system-termination-cable","title":"P0931RM Foxboro I\/A Series Redundant System Termination Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-159\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-159\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-159\"\u003eP0931RM (P0931RM)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-159\"\u003e is a high-integrity \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-159\"\u003eType 1 Termination Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-159\"\u003e specifically engineered for the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-159\"\u003eFoxboro I\/A Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-159\"\u003e FBM216b HART® Communication Redundant Input Subsystem\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-159 citation-end-159\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-158\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-158\"\u003eThis cable provides the critical physical link between the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-158\"\u003eFBM216b Redundant Adapter (P0924DT)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-158\"\u003e and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-158\"\u003eCompression-type Termination Assembly (P0924JH)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-158 citation-end-158\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-157\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-157\"\u003eDesigned for high-availability environments such as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-157\"\u003eoil refineries\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-157\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-157\"\u003epower utility plants\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-157\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-157\"\u003echemical processing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-157\"\u003e, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-157\"\u003eP0931RM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-157\"\u003e ensures that individually isolated HART input signals are transmitted without loss or interference\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-157 citation-end-157\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-156\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eBy utilizing premium Polyurethane materials, this cable maintains system uptime in mission-critical loops where signal failure is not an option\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-156 citation-end-156\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eAs a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eType 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem cable, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0931RM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its specific electrical properties and physical construction tailored for redundant HART signal processing:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-155\"\u003eRedundancy Architecture:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-155\"\u003e The cable connects to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-155\"\u003eRedundant Adapter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-155\"\u003e, which combines signals from two adjacent FBM216b modules (Master and Tracker) into a single 25-pin output to the field\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-155 citation-end-155\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-154\"\u003ePhysical Interface:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-154\"\u003e It features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-154\"\u003e37-pin D-subminiature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-154\"\u003e connector at the FBM Baseplate end and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-154\"\u003e25-pin D-subminiature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-154\"\u003e connector at the Termination Assembly end\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-154 citation-end-154\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-153\"\u003eMaterial Composition:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-153\"\u003e Constructed with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-153\"\u003ePolyurethane outer jacket\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-153\"\u003e and semi-rigid PVC primary conductor insulation, providing superior durability against industrial wear\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-153 citation-end-153\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-152\"\u003eStandardized Length:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-152\"\u003e This specific model (\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-152\"\u003eP0931RM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-152\"\u003e) is the designated part number for the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-152\"\u003e2.0 meter (6.6 feet)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-152\"\u003e version within the Type 1 cable family\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-152 citation-end-152\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-151\"\u003eP0931RM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-151\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-151 citation-end-151\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-150\"\u003eFoxboro (Invensys\/Schneider Electric)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-150\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-150 citation-end-150\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-149\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eType 1 Termination Cable\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-149 citation-end-149\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-148\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e2.0 m (6.6 ft)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-148 citation-end-148\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-147\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e37-pin D-subminiature (Baseplate End)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-147 citation-end-147\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector B\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-146\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e25-pin D-subminiature (TA End)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-146 citation-end-146\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eJacket Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-145\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003ePolyurethane (P\/PVC)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-145 citation-end-145\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-144\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e-20 to +80 deg C (-4 to +176 deg F)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-144 citation-end-144\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSubsystem Use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-143\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eFBM216b Redundant Input Interface\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-143 citation-end-143\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCan the P0931RM cable be used with non-redundant FBMs?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-142\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-142\"\u003eNo, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-142\"\u003eP0931RM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-142\"\u003e is a Type 1 cable specifically validated for use with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-142\"\u003eFBM216b redundant adapter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-142\"\u003e configuration\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-142 citation-end-142\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. For non-redundant 100 Series or 200 Series modules, different cable types are required to match the pin-out of standard baseplates.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat is the difference between P0931RM and the LSZH version?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-141\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-141\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-141\"\u003eP0931RM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-141\"\u003e uses Polyurethane (P\/PVC) with a temperature limit of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-141\"\u003e+80 deg C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-141 citation-end-141\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-140\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-140\"\u003eThe LSZH version (\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-140\"\u003eP0928AC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-140\"\u003e) is \"Low Smoke Zero Halogen,\" designed for safety-critical areas where toxic smoke must be avoided during a fire, and supports up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-140\"\u003e+105 deg C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-140 citation-end-140\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes this cable support HART digital communication?\u003c\/strong\u003eYes. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-139\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-139\"\u003eThe cable is designed to carry the 4 to 20 mA analog signal with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-139\"\u003edigital HART FSK signal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-139\"\u003e superimposed, maintaining the integrity of bi-directional digital communications with field devices\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-139 citation-end-139\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStrain Relief:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e37-pin D-sub\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eend to the redundant adapter, ensure the mounting lugs are tightened to prevent vibration-induced signal intermittent.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBending Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum bending radius of at least 10 times the cable diameter. Avoid sharp 90-degree bends near the connectors to prevent internal conductor fatigue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-138\"\u003eRouting:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-138\"\u003e Although the Polyurethane jacket is rugged, keep the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-138\"\u003eP0931RM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-138\"\u003e separate from high-voltage AC power lines within the cabinet to minimize EMI (Electromagnetic Interference) on the 4-20mA HART loops\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-138 citation-end-138\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-137\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-137\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-137\"\u003eP0931RM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-137\"\u003e is part of a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-137\"\u003eUL\/UL-C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-137\"\u003e listed and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-137\"\u003eATEX Zone 2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-137\"\u003e certified subsystem\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-137 citation-end-137\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-136\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-136\"\u003eIts construction is suitable for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-136\"\u003eClass G3 (Harsh)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-136\"\u003e environments, providing 15-bit resolution accuracy for HART signals even in corrosive or high-humidity atmospheres\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-136 citation-end-136\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-135\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-135\"\u003eThe use of standard D-sub connectors allows for rapid \"Plug-and-Play\" replacement, which is critical for maintaining the high availability of the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-135\"\u003eFBM216b\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-135\"\u003e redundancy pair\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-135 citation-end-135\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695401595243,"sku":"P0931RM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/foxboro-p0931rm-term-cable-jp0b3s3j0cd_0e9a1d17-a604-4251-a743-b8db12f6baf8.jpg?v=1766133772"},{"product_id":"foxboro-fbm232-p0926gw-ethernet-communication-module","title":"Foxboro FBM232 P0926GW Ethernet Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM 232 (FBM232)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eP0926GW is a high-performance Ethernet Device Communications Interface Module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro I\/A Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System (DCS). It serves as a critical bridge between the DCS control network and external Ethernet-based devices, such as PLCs, motor control centers, and smart transmitters. Engineered for demanding industries including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil refining\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eheavy mining\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM 232\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates real-time data exchange via various protocols (e.g., Modbus TCP\/IP). By integrating third-party subsystem data into the global database, this module eliminates data silos and provides operators with comprehensive visibility, which is essential for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereducing unplanned downtime\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand optimizing plant-wide safety.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM 232\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for high-reliability industrial networking. It features a specialized hardware design that offloads communication processing from the main Fieldbus Processor (FCP), ensuring control loop integrity is never compromised by heavy network traffic.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports multiple software drivers, primarily facilitating\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10\/100 Mbps Ethernet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen deployed in a redundant pair, the modules operate in an active\/waiting configuration. If the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0926GW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edetects a hardware or link failure, the backup module assumes control within milliseconds to maintain continuous process monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation \u0026amp; Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides galvanic isolation between the Ethernet port and the internal backplane, protecting the sensitive DCS core from field-side electrical transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFBM 232 P0926GW\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFoxboro (Schneider Electric)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet Communication Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Mbps Auto-sensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5 W (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 mm x 102 mm x 114 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the FBM 232 P0926GW support redundant Ethernet cabling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. To achieve full communications redundancy, two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM 232\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules must be installed in a redundant baseplate. Each module connects to independent network switches to ensure no single point of failure exists in the data path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I identify a communication timeout via the module LEDs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features a \"Status\" LED. A flashing red pattern usually indicates a configuration mismatch or a loss of link to the external device. Consult the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/A Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem Manager for specific error codes associated with the ECB (Equipment Control Block).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the P0926GW hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM 232\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for hot-plugging. It can be removed or replaced without removing power from the baseplate or affecting the operation of other FBMs in the same rack.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways use High-Quality Shielded Twisted Pair (STP) Cat5e or Cat6 cables for Ethernet connections. Ensure the shield is grounded at the patch panel to prevent noise injection into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0926GW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum clearance of 50 mm above and below the baseplate assembly. Excessive heat buildup in enclosed cabinets can degrade the MTBF (Mean Time Between Failure) of the Ethernet transceivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIP Address Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore physical installation, ensure the MAC address of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM 232\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis documented and the corresponding IP address is reserved in the plant's managed switch to avoid IP conflicts during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM 232\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a ruggedized industrial design that exceeds standard commercial IT equipment. It is rated for Class 1, Division 2 hazardous locations, making it suitable for direct installation in field-mounted cabinets. Its \"Future-Proof\" firmware allows for protocol updates without hardware changes, ensuring long-term compatibility with evolving industrial Ethernet standards.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695402316139,"sku":"FBM232 P0926GW","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/foxboro-fbm232-p0926gw-ethernet-communication-module-j33me2tqcqb_4f86aa6d-f169-4912-ad7c-087877992993.jpg?v=1766133813"},{"product_id":"foxboro-fcm2f10-p0916tq-fieldbus-communications-module","title":"Foxboro FCM2F10 P0916TQ Fieldbus Communications Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCM2F10 (FCM2F10)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eP0916TQ is a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFieldbus Communications Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro I\/A Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control system (DCS). This specific variant provides a critical fiber optic interface, enabling seamless communication between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFieldbus Processor (FBP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand remote\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFieldbus Modules (FBMs)\u003c\/strong\u003e. Designed for mission-critical industrial environments such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epetrochemical refining\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eutility power generation\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge-scale mining operations\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCM2F10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures high-speed data integrity over extended distances. By utilizing fiber optic media, it provides total electrical isolation and immunity to electromagnetic interference (EMI), significantly\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereducing unplanned downtime\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecaused by signal degradation or lightning strikes in outdoor cable runs.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCM2F10 P0916TQ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a signal converter and repeater within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHDLC fieldbus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture. It transitions the internal copper-based backplane signals to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 Mbps fiber optic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elinks.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiber Optic Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with ST-type connectors supporting multimode fiber, allowing for fieldbus extension up to 2 km without signal regeneration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports dual-baud rate detection and can be deployed in redundant pairs. In a redundant configuration, if one fiber link fails, the twin module maintains the communication link to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecluster without process interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP0916TQ Baseplate Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module is designed for hot-swappable installation into standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModular Baseplates\u003c\/strong\u003e, utilizing the high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBaseplate Internal Bus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor power and data synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFCM2F10 P0916TQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFoxboro (Schneider Electric)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFieldbus Communications (Fiber Optic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFiber Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultimode (ST Connectors)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Distance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 km (1.2 miles)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 W (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 mm x 100 mm x 115 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FCM2F10 P0916TQ replace an older FCM2F2 copper module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCM2F10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for fiber optic media. Replacing a copper module requires changing the cabling infrastructure to fiber and ensuring the corresponding baseplate supports fiber optic transceivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a solid red \"FAIL\" LED indicate on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA solid red LED typically indicates a fatal hardware failure or a loss of the internal\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 Mbps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eclock signal. If power cycling the baseplate does not clear the error, the module requires replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require software configuration in the I\/A Series Integrated Control Software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCM2F10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis largely transparent to the software; however, it must be correctly identified in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLetterbug\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration of the associated Fieldbus Processor to ensure proper diagnostic reporting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiber Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing fiber jumpers to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0916TQ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eports, maintain a minimum bend radius of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30 mm\u003c\/strong\u003e. Sharp bends cause excessive decibel (dB) loss, leading to intermittent \"Module Missing\" errors in the DCS system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDust Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways keep the plastic dust caps on the ST connectors until the moment the fiber optic cable is attached. Even microscopic dust particles on the lens can attenuate the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e850 nm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elight signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the module is hot-swappable, it is best practice to \"Disable\" the module via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem Management\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edisplay before physical removal to prevent transient bus errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCM2F10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLevel G3 (Harsh)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments as defined by ISA-S71.04, featuring conformal coating to resist chemical corrosion. Its fiber optic physical layer provides an inherent \"Air Gap\" that protects the central\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCP270\/FCP280\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessors from field-side electrical surges. This makes it the gold standard for distributed architectures where I\/O racks are located in separate buildings or near high-voltage motor control centers (MCC).\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695402578283,"sku":"FCM2F10 P0916TQ","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/foxboro-fcm2f10-p0916tq-fieldbus-communications-module-sx13lbi31dq_dafdcc1b-0283-4663-afda-488e37116be3.jpg?v=1766133831"},{"product_id":"foxboro-fbm217-p0914tr-discrete-input-module","title":"Foxboro FBM217 (P0914TR) Discrete Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM217 (P0914TR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, 32-channel Discrete Input Module designed for the Foxboro I\/A Series and EcoStruxure Foxboro DCS. It serves as the primary interface for monitoring digital field signals, such as dry contacts or DC voltage sources from pushbuttons, limit switches, and motor starter auxiliary contacts.\u003c\/p\u003e\n\u003cp\u003eIn industrial automation, the FBM217 is recognized for its versatility; depending on the associated Terminal Assembly (TA), it can monitor a wide range of voltages, including 24 V DC, 125 V DC, 120 V AC, or 240 V AC. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0914TR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation refers to the specific hardware assembly of the module, which is engineered for high-availability process control in demanding environments like power generation and chemical manufacturing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe FBM217 architecture is optimized for group isolation and redundant signal processing:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides 32 discrete input channels in a compact \"plug-in\" form factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan be deployed as a single unit or as a redundant pair. When configured in a pair, the modules provide \"bumpless\" switchover, ensuring that a single module failure does not interrupt the monitoring of critical process interlocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConverts field-side electrical signals (voltage or contact state) into digital data for the Field Control Processor (FCP) via the redundant 2 Mbps or 10 Mbps Fieldbus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGroup Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 32 channels are group-isolated from the internal system logic, providing a robust buffer against field-side electrical noise and transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFBM217\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eP0914TR\u003c\/strong\u003e (Housed Module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Input (Voltage Monitor or Contact Sense)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC Group Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70°C (-4 to +158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eISA-S71.04 Class G3 (Conformal Coated)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX Zone 2 \/ Class I, Div 2 Certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the difference between FBM217 and P0914TR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM217\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the functional model name used in DCS software and system design.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0914TR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the specific hardware part number for the module assembly. They refer to the same physical unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this module require an external power source for the inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: It depends on the application. For \"Contact Sense,\" the module\/TA provides the wetting voltage. For \"Voltage Monitor,\" the module monitors an external DC or AC source provided by the field device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the FBM217 be hot-swapped?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. The FBM217 supports full hot-pluggable capability. On a redundant baseplate, a failed module can be removed and replaced without powering down the system or losing signal visibility.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBaseplate Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FBM217 (P0914TR) must be installed on a 200 Series Modular Baseplate (e.g.,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRH924YF\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0926KE\u003c\/strong\u003e). Ensure the locking handles are fully engaged to secure the module to the Fieldbus pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilter Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent \"contact bounce\" from mechanical switches, engineers should configure the input filter time (software-selectable) to ensure stable signal detection in the DCS logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Assembly (TA) Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FBM217 must be paired with the correct TA (e.g.,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0916BT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor 24V DC contact sense) and the appropriate termination cable (\u003cstrong\u003eP0926GQ\u003c\/strong\u003e) to match the specific field voltage requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe FBM217's\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3-rated conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical engineering advantage, protecting the internal electronics from corrosion caused by sulfur dioxide (\u003cspan class=\"math-inline\"\u003eSO2\u003c\/span\u003e) and hydrogen sulfide (\u003cspan class=\"math-inline\"\u003eH2S\u003c\/span\u003e). Its ability to handle 32 channels in a single slot significantly reduces the footprint in the I\/O cabinet, while its support for millisecond-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSequence of Events (SOE)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erecording is vital for post-trip analysis in safety-critical systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695403299179,"sku":"FBM217 P0914TR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/foxboro-fbm217-p0914tr-discrete-input-module-jao4hdlke5a_9687ec8b-c880-48a9-b491-22fcad689480.jpg?v=1766133890"},{"product_id":"foxboro-p0926jm-internal-board-for-fbm231-fcm-b-position-interface","title":"Foxboro P0926JM (Internal Board for FBM231\/FCM) B-Position Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0926JM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the core internal hardware assembly (PCBA) for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM231\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiscrete I\/O Module and various\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Fieldbus Communication Modules) within the Foxboro I\/A Series system.\u003c\/p\u003e\n\u003cp\u003eUnlike a complete encased module, the P0926JM represents the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal electronic backbone\u003c\/strong\u003e. It is specifically engineered to interface with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB-Position\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eslot on Foxboro\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModular Baseplates\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(such as the RH924YF and P0926KE). This component is essential for repair and maintenance, allowing technicians to restore module-to-backplane communication without replacing the entire module housing or baseplate infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCore Function:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides the high-speed 32-channel discrete signal routing and bus interface logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB-Position Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed to occupy the B-Position within the modular baseplate architecture, managing the primary\/redundant data path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 1500 V AC galvanic isolation to protect the DCS control network from field-side electrical surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISA-S71.04 Class G3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econformal coating (as visible on the board surface), ensuring maximum resistance to corrosive industrial gases (\u003cspan class=\"math-inline\"\u003e$H_2S$\u003c\/span\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$SO_2$\u003c\/span\u003e, etc.).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eP0926JM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Model\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFBM231 \/ FCM Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Slot\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB-Position\u003c\/strong\u003e (Modular Baseplate Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC Discrete\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoard Finish\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eG3 Conformal Coated (Anti-Corrosion)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal PCBA (Board Only)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the P0926JM a complete Field Bus Module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. It is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal electronic assembly (PCBA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efound inside FBM231. This listing is for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebare board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas shown in the photos, used primarily for hardware-level repairs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What does \"B-Position\" mean in the title?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: On a Foxboro Modular Baseplate, the modules must connect to specific internal bus positions. The P0926JM is the hardware interface that physically and logically connects to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB-Position\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epins.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I use this to repair a failed FBM231?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. This is the most cost-effective way to fix a module with internal electronic failure while reusing your existing plastic housing and handles.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSwapping the P0926JM should be done in an ESD-safe environment. The board fits precision-keyed slots within the FBM\/FCM housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Note:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the partner module in redundant pairs is healthy before performing an internal board swap to maintain process continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Inspection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe high-quality G3 coating on this P0926JM ensures it can be deployed in harsh \"near-process\" cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695403331947,"sku":"P0926JM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/foxboro-p0926jm-clamp-base-module-kfcs5kqfccg_3dff7bb5-a11f-46cd-80f0-8dd4a0615090.jpg?v=1766133892"},{"product_id":"rh924yf-foxboro-i-a-series-fcp280-din-rail-mounted-modular-baseplate","title":"RH924YF Foxboro I\/A Series FCP280 DIN-Rail Mounted Modular Baseplate","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRH924YF (RH924YF)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, DIN-rail mounted modular baseplate specifically designed for the Foxboro I\/A Series (now EcoStruxure Foxboro DCS). It serves as the foundational mounting and interconnection infrastructure for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Processor 280 (FCP280)\u003c\/strong\u003e. In mission-critical distributed control environments—such as global oil and gas facilities, pharmaceutical plants, and large-scale utility grids—the RH924YF provides the mechanical stability and electrical backplane necessary for the FCP280 to manage complex control algorithms and high-speed Fieldbus communication. Its modular design allows for flexible system expansion while ensuring that the control processors remain securely seated and interconnected within the industrial enclosure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe RH924YF is engineered to support the dual-processor redundancy and high-speed data exchange requirements of the FCP280.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Slots:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe baseplate features two dedicated slots for FCP280 modules, enabling a redundant (fault-tolerant) pair configuration. This ensures that if the primary processor fails, the secondary takes over without process interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Fieldbus Backplane:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt contains a high-speed communication backplane that facilitates data transfer between the FCP280s and the connected Field Bus Modules (FBMs) via the 2 Mbps or 10 Mbps Fieldbus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe RH924YF incorporates dual power input terminals, allowing for independent power feeds (e.g., FPS480-24 power supplies). This prevents a single power supply failure from taking the entire control node offline.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTime Strobe \u0026amp; Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes circuitry to support Time Strobe signals, ensuring that all events recorded by the processors are synchronized with millisecond precision across the entire DCS network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRH924YF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFoxboro (Schneider Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFCP280 Modular Baseplate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal or Vertical DIN-rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFCP280 (Single or Redundant Pair)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Redundant 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area Cert\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX Zone 2 \/ Class I, Div 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConformal Coating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA-S71.04 Class G3 (Harsh)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the FCP280 be \"hot-swapped\" on the RH924YF baseplate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes, the RH924YF supports full Hot Plug\/Unplug capability. A failed FCP280 can be removed and a new one inserted while the redundant partner remains operational, ensuring zero downtime for the control loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the benefit of the DIN-rail mounting for this baseplate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The DIN-rail design allows for rapid installation in standard industrial cabinets without specialized mounting racks. This modularity makes it easier to upgrade legacy FCP270 systems to FCP280 technology using the same footprint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the RH924YF provide the connection for the Fieldbus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, the baseplate features dedicated connectors (typically HDLC or Ethernet-based depending on the system revision) to link the processors to the Fieldbus expansion cables.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure signal integrity and protection against EMI, the baseplate must be securely bonded to the cabinet's safety ground. Ensure the DIN-rail itself is properly grounded to the enclosure frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mounting multiple RH924YF units, maintain a minimum vertical clearance of at least 50 mm (2 inches) between baseplates to allow for adequate airflow and heat dissipation from the active processors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeying and Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFCP280 modules are precision-keyed. Never force a module onto the RH924YF; ensure the locking tabs are fully disengaged before insertion, and firmly lock them once the module is seated to prevent vibration-related contact wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe RH924YF is a key enabler of the FCP280's industry-leading performance. By providing a G3-rated (corrosion resistant) backplane, it allows the control system to be deployed in harsh environments—such as near cooling towers or chemical reactors—where standard electronics would fail. The integration of time-synchronization logic directly into the baseplate hardware allows for Sequence of Events (SOE) logging that is critical for post-trip forensic analysis. Furthermore, its downward compatibility with existing 200 Series I\/O ensures that plant owners can modernize their control logic while preserving their investment in field wiring and I\/O modules.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695403430251,"sku":"RH924YF","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/foxboro-rh924yf-fcp280-din-rail-mounted-modular-baseplate-zxqdfoixpn5_a70fa387-d90b-4a3b-9c3e-0cad0a83f6b0.jpg?v=1766133905"},{"product_id":"foxboro-p0926gq-32-channel-fbm-termination-cable","title":"Foxboro P0926GQ 32-Channel FBM Termination Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0926GQ (P0926GQ)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density 32-channel termination cable specifically engineered for the Foxboro I\/A Series system. It functions as the indispensable physical interconnect between 32-channel Field Bus Modules—such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM217, FBM231, and FBM224\u003c\/strong\u003e—and their respective Terminal Assemblies (TA). In complex industrial DCS architectures, this cable ensures the reliable, noise-immune transmission of discrete input and output signals. By utilizing a pre-fabricated, plug-and-play design, the P0926GQ eliminates the need for manual point-to-point wiring, significantly reducing commissioning time and preventing potential cross-wiring errors in mission-critical control environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eP0926GQ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFoxboro (Schneider Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-Channel Shielded Termination Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFBM217, FBM224, FBM231, FBM242\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-density Multi-pin with Locking Screws\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-pair Stranded Copper (Shielded)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFlame Retardancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVW-1 Rated Jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe P0926GQ allows for a universal connection across multiple 32-channel discrete FBM types, simplifying spare parts inventory (MRO) for large-scale plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIts high-grade shielding prevents electromagnetic interference (EMI) from neighboring power cables or variable frequency drives (VFDs) from causing false digital triggers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of an FBM failure, the P0926GQ can be quickly disconnected, allowing for \"hot-swap\" module replacement without disturbing the field wiring on the Terminal Assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695404085611,"sku":"P0926GQ","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/foxboro-p0926gq-type-5-hypalon-termination-cable-pr5wksrvetr_60464967-7794-4d06-ba01-4276616c49d1.jpg?v=1766133954"},{"product_id":"foxboro-fbm202-p0916ac-thermocouple-mv-input-module","title":"Foxboro FBM202 P0916AC Thermocouple\/mV Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro FBM202 P0916AC\u003c\/strong\u003e is a DIN rail-mounted passive termination assembly designed to interface eight isolated thermocouple\/mV analog input signals with an \u003cstrong\u003eFBM202\u003c\/strong\u003e module within the \u003cstrong\u003eFoxboro I\/A Series\u003c\/strong\u003e and \u003cstrong\u003eFoxboro Evo\u003c\/strong\u003e DCS platforms. The \u003cstrong\u003eP0916AC\u003c\/strong\u003e termination assembly incorporates a 4-wire 100 ohm platinum RTD (IEC 751, Class B) to provide cold-junction reference temperature compensation for accurate thermocouple measurements. Each input channel on the associated \u003cstrong\u003eFBM202\u003c\/strong\u003e module provides galvanic isolation from other channels and ground, supporting standard thermocouple types B, E, J, K, N, R, S, T, and millivolt input signals. Signal processing involves per-channel Sigma-Delta A\/D conversion, upscale thermocouple burnout detection, and configurable integration periods. The \u003cstrong\u003eP0916AC\u003c\/strong\u003e termination assembly connects to the baseplate-mounted \u003cstrong\u003eFBM202\u003c\/strong\u003e module via a removable Type 2 termination cable, conveying field signals to the module and communicating via the redundant 2 Mbps module Fieldbus to Fieldbus Communication Modules or Control Processors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight-channel field I\/O feedthrough connection with channel-to-channel galvanic isolation\u003c\/li\u003e\n\u003cli\u003eIntegrated 4-wire 100 ohm platinum RTD (IEC 751, Class B) for reference junction compensation\u003c\/li\u003e\n\u003cli\u003eCompression screw terminal connections accepting 0.2 to 4 mm2 (24 to 12 AWG) field wiring\u003c\/li\u003e\n\u003cli\u003ePolyvinyl chloride (PVC) housing construction rated for -20 to +50 degC operating temperatures\u003c\/li\u003e\n\u003cli\u003ePassive feedthrough interface supporting Type 2 termination cables up to 30 m in length\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting design compatible with 32 mm and 35 mm DIN rails\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy performance utilizing per-channel Sigma-Delta A\/D conversion on the FBM202\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermocouple signal interfacing for DCS temperature loops\u003c\/li\u003e\n\u003cli\u003eProcess temperature monitoring with cold junction compensation\u003c\/li\u003e\n\u003cli\u003eMillivolt input processing for industrial automation systems\u003c\/li\u003e\n\u003cli\u003eReplacement and upgrade of Foxboro 100 Series FBM02 field wiring setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0916AC\u003c\/td\u003e\n\u003ctd\u003eEight-channel thermocouple\/mV passive feedthrough TA with RTD\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003ctd\u003eCompression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0916AD\u003c\/td\u003e\n\u003ctd\u003eEight-channel thermocouple\/mV passive feedthrough TA with RTD\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003ctd\u003eRing Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0916XH\u003c\/td\u003e\n\u003ctd\u003eEight-channel thermocouple\/mV passive feedthrough TA with RTD\u003c\/td\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003ctd\u003eCompression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0917JL\u003c\/td\u003e\n\u003ctd\u003eEight-channel thermocouple\/mV passive feedthrough TA with RTD\u003c\/td\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003ctd\u003eRing Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0928CN\u003c\/td\u003e\n\u003ctd\u003eBaseplate-mounted TA for two sets of eight thermocouple\/mV channels\u003c\/td\u003e\n\u003ctd\u003ePC\/ABS\u003c\/td\u003e\n\u003ctd\u003eCompression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFoxboro by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eP0916AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCompatible Module\u003c\/td\u003e\n\u003ctd\u003eFBM202 (P0926EQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 isolated thermocouple\/mV input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-10.5 to +69.5 mV dc (0 to 64000 raw counts); Full range: 71.419 mV (65535 raw counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eB, E, J, K, N, R, S, T and other millivolt signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDifferential Input Impedance\u003c\/td\u003e\n\u003ctd\u003e10 Mohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBurnout Detection\u003c\/td\u003e\n\u003ctd\u003eFull upscale value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCommon Mode Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 30 V ac or 60 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy \u0026amp; Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMillivolt Input Accuracy\u003c\/td\u003e\n\u003ctd\u003e+0.03% of span (+-27 uV) at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRTD Channel Accuracy\u003c\/td\u003e\n\u003ctd\u003e+0.03% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRTD Reference Junction Conformity\u003c\/td\u003e\n\u003ctd\u003e+-0.25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eThermocouple Conformity\u003c\/td\u003e\n\u003ctd\u003e+0.25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAccuracy Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e+-50 ppm\/degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRTD Reference Junction Measurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+-0.50 degC (using RTD internal to Foxboro TAs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eReference Junction Type\u003c\/td\u003e\n\u003ctd\u003e4-wire 100 ohm platinum RTD (IEC 751, Class B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation per channel; withstands 600 V ac for 1 minute between channel and ground or channel to channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature (PVC TA)\u003c\/td\u003e\n\u003ctd\u003e-20 to +50 degC (-4 to +122 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC (-40 to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e-300 to +3,000 m (-1,000 to +10,000 ft) operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eContamination\u003c\/td\u003e\n\u003ctd\u003eClass G3 (Harsh) per ISA Standard S71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA Material\u003c\/td\u003e\n\u003ctd\u003ePolyvinyl Chloride (PVC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eCompression screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCompression Accepted Wiring Sizes\u003c\/td\u003e\n\u003ctd\u003eSolid\/Stranded: 0.2 to 4 mm2 \/ 24 to 12 AWG; Stranded with Ferrules: 0.2 to 2.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWeight (Compression TA)\u003c\/td\u003e\n\u003ctd\u003e159 g (0.35 lb) approximate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions (Compression TA)\u003c\/td\u003e\n\u003ctd\u003e125 mm x 76 mm x 72 mm (4.93 in x 2.99 in x 2.83 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Termination Compression Screw\u003c\/td\u003e\n\u003ctd\u003eDirect connection for 8 two-wire thermocouple\/mV analog input field signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal RTD Connection\u003c\/td\u003e\n\u003ctd\u003eConnections to the integral 4-wire 100 ohm platinum RTD for reference junction compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Interface\u003c\/td\u003e\n\u003ctd\u003e25-pin D-subminiature connector linking to the FBM baseplate via Type 2 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Mount the P0916AC termination assembly on standard 32 mm or 35 mm DIN rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Connection\u003c\/strong\u003e: Connect the 25-pin D-subminiature end of the Type 2 termination cable to the TA and the 37-pin D-subminiature end to the FBM202 baseplate slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring\u003c\/strong\u003e: Insert field wiring into compression screw terminals accepting 0.2 to 4 mm2 (24 to 12 AWG) solid or stranded conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Limits\u003c\/strong\u003e: Ensure field wiring voltages do not exceed 30 V ac or 60 V dc to prevent electrical safety code violations and shock hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enclosure\u003c\/strong\u003e: Install in appropriate enclosures when operating in Class G3 harsh environments to comply with environmental ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL\/UL-C\u003c\/strong\u003e: UL\/UL-C listed as suitable for use in Class I, Groups A-D, Division 2, temperature code T4 hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ CENELEC\u003c\/strong\u003e: CENELEC (DEMKO) certified EEx nA IIC T4 for use in Zone 2 potentially explosive atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53689170100587,"sku":"FBM202","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FBM202-P0916AC_001_1200x1200_b36887fb-5338-410b-95dd-8dd68e015420.jpg?v=1786230560"},{"product_id":"foxboro-p0914sv-fbm203-platinum-nickel-copper-rtd-input-module","title":"Foxboro P0914SV FBM203 Platinum\/Nickel\/Copper RTD Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0914SV FBM203\u003c\/strong\u003e is an eight-channel resistance temperature detector (RTD) input module designed for process automation systems. The \u003cstrong\u003eP0914SV\u003c\/strong\u003e accepts 2- or 3-wire RTD sensor inputs within a resistance range of 0 to 320 ohms. Each analog input channel is galvanically isolated from ground and all other channels. The module performs signal conversions to interface electrical input signals from field sensors to a redundant 2 Mbps module fieldbus, executing an analog input application program that provides conversion timing and configurable options for Rate of Change Limits.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight galvanically isolated RTD input channels\u003c\/li\u003e\n\u003cli\u003eHigh accuracy achieved by sigma-delta data conversions for each channel\u003c\/li\u003e\n\u003cli\u003eCompact, rugged design suitable for ISA S71.04 Class G3 harsh environments\u003c\/li\u003e\n\u003cli\u003eExecution of analog input application program with configurable Rate of Change Limits\u003c\/li\u003e\n\u003cli\u003eSupport for DIN rail mounted or baseplate-mounted passive termination assemblies\u003c\/li\u003e\n\u003cli\u003eHot-swappable module replacement without disturbing field wiring, power, or communication cabling\u003c\/li\u003e\n\u003cli\u003eFront-panel LEDs for operational status indications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess temperature monitoring using Platinum or Nickel RTD sensors\u003c\/li\u003e\n\u003cli\u003eIndustrial temperature measurement in Foxboro Evo Control Core Services systems\u003c\/li\u003e\n\u003cli\u003eLegacy 100 Series FBM system upgrades and replacements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFoxboro by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eP0914SV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated RTD channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 320 ohms (320 ohms = 64000 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Current\u003c\/td\u003e\n\u003ctd\u003e0.19 mA dc nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms maximum per lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03% of span (includes linearity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e±50 ppm\/degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration Period\u003c\/td\u003e\n\u003ctd\u003eSoftware configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;125 dB at 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;95 dB at 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation per channel, 600 V ac for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e24 V dc +5%, -10% (Redundant input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e3 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e284 g approximate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e102 mm x 45 mm x 104 mm (114 mm height including mounting lugs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e-300 to +3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eClass G3 (Harsh) per ISA Standard S71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The module mounts directly onto a DIN rail mounted Modular Baseplate (4-slot or 8-slot) or a 100 Series conversion mounting structure. Baseplates can be installed horizontally or vertically on a DIN rail, or horizontally in a 19-inch rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Replacement:\u003c\/strong\u003e Designed for removal and replacement without taking down field device wiring, power supply, or fieldbus communication cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Field I\/O signals connect through dedicated DIN rail mounted or baseplate-mounted Termination Assemblies (TAs) using compression screw or ring lug terminals via removable termination cables up to 30 meters in length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European EMC Directive 89\/336\/EEC (EN 50081-2, EN 50082-2, EN 61326 Annex A, CISPR 11 Class A, IEC 61000-4-2\/3\/4\/5\/6\/8)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Safety:\u003c\/strong\u003e UL\/UL-C listed for Class I, Groups A-D; Division 2; temperature code T4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e CENELEC (DEMKO) certified EEx nA [NL] IIC T4 for Zone 2 explosive atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53689182585195,"sku":"P0914SV FBM203","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/P0914SV-FBM203_001_1200x1200_7f143d3e-b044-4c65-b970-59fba642a53a.jpg?v=1786230993"},{"product_id":"foxboro-p0916nk-9-pin-hdlc-base-to-base-cable","title":"Foxboro P0916NK 9 Pin HDLC Base-To-Base Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0916NK\u003c\/strong\u003e is a High-Level Data Link Control (\u003cstrong\u003eHDLC\u003c\/strong\u003e) base-to-base communication cable used for interconnecting system baseplates within Foxboro industrial control systems. The \u003cstrong\u003eP0916NK\u003c\/strong\u003e facilitates data transfer across hardware bases, providing dedicated physical signal connections between system nodes. Featuring a 9-pin male to 9-pin male connector configuration, this assembly establishes point-to-point serial communication links across a compact 5-1\/4 inch length.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHDLC\u003c\/strong\u003e communication support for base-to-base system links\u003c\/li\u003e\n\u003cli\u003eDual 9-pin male connector configuration\u003c\/li\u003e\n\u003cli\u003eCompact 5-1\/4 inch cable length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterconnecting adjacent Foxboro system baseplates\u003c\/li\u003e\n\u003cli\u003eBase-to-base \u003cstrong\u003eHDLC\u003c\/strong\u003e communication links in process control architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eP0916NK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eHDLC Base-To-Base Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector A\u003c\/td\u003e\n\u003ctd\u003e9 Pin Male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector B\u003c\/td\u003e\n\u003ctd\u003e9 Pin Male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e5-1\/4 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9-Pin Male (Side A)\u003c\/td\u003e\n\u003ctd\u003eHDLC Base Connection A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9-Pin Male (Side B)\u003c\/td\u003e\n\u003ctd\u003eHDLC Base Connection B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure system power is disconnected or appropriate bus maintenance procedures are followed before connecting or disconnecting the cable.\u003c\/li\u003e\n\u003cli\u003eSecure both 9-pin male connectors firmly to the corresponding mating baseplate receptacles to ensure reliable contact and grounding continuity.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive bending, twisting, or strain on the short 5-1\/4 inch cable assembly during routing between baseplates.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53689732235627,"sku":"P0916NK","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/P0916NK_001_1200x1200_ad7be20f-9a2d-419a-b204-8c3516cf6e9a.jpg?v=1786231573"},{"product_id":"foxboro-ipm2-p0904ha-i-a-series-industrial-power-module-2","title":"Foxboro IPM2-P0904HA I\/A Series Industrial Power Module 2","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro IPM2-P0904HA\u003c\/strong\u003e is an industrial power supply module designed for use within the Foxboro I\/A Series system. The \u003cstrong\u003eIPM2-P0904HA\u003c\/strong\u003e converts AC input voltage into a regulated 39 VDC output to power system hardware components and field equipment. It supports selectable AC input ranges (100, 120, 220, or 240 VAC) at 50\/60 Hz and features front-panel status LEDs for real-time operational monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable AC input voltages: 100 VAC, 120 VAC, 220 VAC, and 240 VAC\u003c\/li\u003e\n\u003cli\u003eRegulated 39 VDC output\u003c\/li\u003e\n\u003cli\u003eStatus LEDs for diagnostic indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePowering Foxboro I\/A Series system equipment and modules\u003c\/li\u003e\n\u003cli\u003eIndustrial automation power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric \/ Invensys \/ Foxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIPM2-P0904HA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eP0904HA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100 VAC (0.95 A), 120 VAC (0.79 A), 220 VAC (0.43 A), 240 VAC (0.40 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e39 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e1.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Level\u003c\/td\u003e\n\u003ctd\u003eLevel 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the unit is properly connected to an external earth ground during installation.\u003c\/li\u003e\n\u003cli\u003eVerify that the input voltage selection corresponds correctly to the local AC supply voltage (100, 120, 220, or 240 VAC) before applying power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFM Approved\u003c\/li\u003e\n\u003cli\u003eCSA NRTL\/C Certified\u003c\/li\u003e\n\u003cli\u003eClass 1 Division 2 Groups A, B, C, and D, T4A at 75 degC Max\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53689756123499,"sku":"IPM2-P0904HA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IPM2-P0904HA_005_1200x1200_bfa9cd22-97d1-47c1-848d-4e9936d8374f.jpg?v=1786232233"},{"product_id":"foxboro-p0973cn-i-a-series-expansion-baseplate","title":"Foxboro P0973CN I\/A Series Expansion Baseplate","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0973CN\u003c\/strong\u003e is a 4-position vertical DIN rail mounted expansion baseplate used in the Foxboro I\/A Series DCS. It provides a dedicated hardware platform to house a fault-tolerant pair of \u003cstrong\u003eFCP270\u003c\/strong\u003e field control processors in two positions and a redundant pair of \u003cstrong\u003eFEM100\u003c\/strong\u003e fieldbus expansion modules in the remaining two positions. Operating on a passive backplane structure, the \u003cstrong\u003eFoxboro P0973CN\u003c\/strong\u003e delivers high-reliability power routing and communication interconnections across the 2 Mbps Module Fieldbus. Mounting positions are specifically integrated onto the baseplate to accommodate fiber optic splitter\/combiners required for fault-tolerant \u003cstrong\u003eFCP270\u003c\/strong\u003e processor operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVertical DIN rail mounting configuration for standard enclosure layouts.\u003c\/li\u003e\n\u003cli\u003eFour dedicated module positions configured for two FCP270 processors and two FEM100 modules.\u003c\/li\u003e\n\u003cli\u003eIntegrated mounting space for fiber optic splitter\/combiners to support FCP270 redundancy.\u003c\/li\u003e\n\u003cli\u003eDual primary and secondary 24 V dc power connections.\u003c\/li\u003e\n\u003cli\u003eShielded twisted-pair Module Fieldbus interconnections operating at 2 Mbps.\u003c\/li\u003e\n\u003cli\u003eHot-swappable module support allowing unit addition or replacement without disrupting active bus communication.\u003c\/li\u003e\n\u003cli\u003ePassive backplane architecture designed to maximize overall DCS operational reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFoxboro I\/A Series DCS system expansion requiring additional 200 Series FBM fieldbus channels.\u003c\/li\u003e\n\u003cli\u003eHigh-density industrial automation control cabinets requiring fault-tolerant processing and fieldbus expansion.\u003c\/li\u003e\n\u003cli\u003eContinuous processing plant infrastructure utilizing DIN rail mounted hardware subsystems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Invensys)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0973CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eFoxboro I\/A Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e4 Module Positions (2x FCP270, 2x FEM100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 V dc +5%, -10% (Redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003e2 Mbps HDLC Module Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate ID DIP Switch\u003c\/td\u003e\n\u003ctd\u003eNot present (Does not require hardwired address)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 degC (-4 to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC (-40 to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e-300 to +3,000 m (-1,000 to +10,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContamination Class\u003c\/td\u003e\n\u003ctd\u003eClass G3 (Harsh) per ISA S71.04; Pollution degree 2 per IEC 664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePC and ABS, inflammability UL94 V0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Length\u003c\/td\u003e\n\u003ctd\u003e60 m (198 ft) total overall Module Fieldbus cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Power Connector\u003c\/td\u003e\n\u003ctd\u003eDirect 24 V dc primary power input connection from FPS power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Power Connector\u003c\/td\u003e\n\u003ctd\u003eDirect 24 V dc secondary power input connection from FPS power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus and Time Strobe A\/B\u003c\/td\u003e\n\u003ctd\u003eConnections for redundant Module Fieldbus (2 Mbps) and optional time strobe signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDedicated FCP270 Slots\u003c\/td\u003e\n\u003ctd\u003eKeyed slots for fault-tolerant FCP270 control processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDedicated FEM100 Slots\u003c\/td\u003e\n\u003ctd\u003eKeyed slots for redundant FEM100 fieldbus expansion modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSplitter\/Combiner Mount\u003c\/td\u003e\n\u003ctd\u003eIntegrated mounting provisions for FCP270 fiber optic splitter\/combiners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Secure the baseplate to a non-isolated, mechanically supported vertical DIN rail using the designated fasteners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Cabling:\u003c\/strong\u003e Connect primary and secondary 24 V dc feed cables from the system power supply (such as FPS400-24, FPS240-24, or FPS120-24) to the primary and secondary power terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldbus Interconnection:\u003c\/strong\u003e Use shielded twisted-pair cables for A\/B Module Fieldbus daisy-chain connections between baseplates, maintaining a maximum total fieldbus length of 60 m (198 ft).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Ensure adequate enclosure clearance around the mounted baseplate to accommodate module insertion, removal, and field wiring clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLive Insertion:\u003c\/strong\u003e Baseplates can be connected or expanded without removing the system from service provided a redundant bus structure is in place.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuropean EMC Directive:\u003c\/strong\u003e 89\/336\/EEC (EN 50081-2, EN 50082-2, EN 61326 Annex A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISM Radio-frequency:\u003c\/strong\u003e CISPR 11 Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity:\u003c\/strong\u003e IEC 61000-4-2 (ESD), IEC 61000-4-3 (Radiated Field), IEC 61000-4-4 (EFT\/Burst), IEC 61000-4-5 (Surge), IEC 61000-4-6 (Conducted), IEC 61000-4-8 (Magnetic Field)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Safety:\u003c\/strong\u003e UL\/UL-C listed for Class 1, Groups A-D, Division 2, T4 enclosure systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuropean Low Voltage Directive:\u003c\/strong\u003e 2006\/95\/EC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Directive:\u003c\/strong\u003e 94\/9\/EC (CENELEC certified EEx n IIC for Zone 2)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53689809961323,"sku":"P0973CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/P0973CN_001_1200x1200_3a20fd1d-807f-40ad-8780-1a7b183aa796.jpg?v=1786234388"},{"product_id":"foxboro-fbm233-p0926gx-i-a-series-ethernet-field-device-system-integrator-module","title":"Foxboro FBM233 P0926GX I\/A Series Ethernet Field Device System Integrator Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro FBM233 P0926GX\u003c\/strong\u003e is an Ethernet Field Device System Integrator (FDSI) module designed for providing an Ethernet interface between single or dual-ported field I\/O devices and the I\/A Series system. The device integrates field device data into an I\/A Series control database using Ethernet connectivity and communicates with field devices using configurable, downloadable software I\/O drivers over 10 Mbps or 100 Mbps Ethernet network transmission rates. It mounts in a Modular Baseplate, interfacing with the system via a redundant 2 Mbps module Fieldbus to an FCM100Et, FCM100E, or FCP270.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant 10 Mbps or 100 Mbps Ethernet network transmission rate to\/from field devices.\u003c\/li\u003e\n\u003cli\u003eCommunicates with up to 64 field devices.\u003c\/li\u003e\n\u003cli\u003eI\/O software driver is downloadable from a library of available protocols.\u003c\/li\u003e\n\u003cli\u003eUp to 2000 DCI block connections.\u003c\/li\u003e\n\u003cli\u003eIntegrates field device data into an I\/A Series control database using Ethernet connectivity.\u003c\/li\u003e\n\u003cli\u003eField mounted.\u003c\/li\u003e\n\u003cli\u003eSuitable for Class G3 (harsh) environments.\u003c\/li\u003e\n\u003cli\u003eLED visual indicators for operational status, transmit\/receive activity, and master\/tracker status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eField device integration into I\/A Series control stations\u003c\/li\u003e\n\u003cli\u003eIndustrial Ethernet communication interfacing with third-party PLCs and field devices\u003c\/li\u003e\n\u003cli\u003eDistributed control interface (DCI) data collection and control output handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Invensys)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eP0926GX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Type\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbps or 100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eUDP\/IP or TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Address\u003c\/td\u003e\n\u003ctd\u003eFixed or DHCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 64 devices per FBM233 maximum with up to 2000 DCI connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Types Transferred\u003c\/td\u003e\n\u003ctd\u003e2-byte or 4-byte signed or unsigned integers, 4-byte IEEE single-precision floating values, or binary values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastest Allowed ECB Block Period\u003c\/td\u003e\n\u003ctd\u003e500 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Fieldbus Communication\u003c\/td\u003e\n\u003ctd\u003eRedundant 2 Mbps module Fieldbus via FCM100Et, FCM100E, or FCP270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 V dc +5%, -10% (Redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumption\u003c\/td\u003e\n\u003ctd\u003e7 W maximum per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e7 W maximum per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 degC (-4 to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC (-40 to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContamination Class\u003c\/td\u003e\n\u003ctd\u003eClass G3 (Harsh) per ISA Standard S71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e102 mm (4 in), 114 mm (4.5 in) including mounting lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e45 mm (1.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e104 mm (4.11 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass\u003c\/td\u003e\n\u003ctd\u003e284 g (10 oz) approximate, per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin \/ Port\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront RJ-45 Connector\u003c\/td\u003e\n\u003ctd\u003eSingle 10\/100Mbps Ethernet connection to field devices, hubs, or switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Connection\u003c\/td\u003e\n\u003ctd\u003eInterfaces to redundant 2 Mbps module Fieldbus and 24 V dc power supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The module mounts on a Modular Baseplate (DIN rail mounted or 19-inch rack mounted) in horizontal or vertical orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Positioning:\u003c\/strong\u003e Redundant module pairs must be located in odd and adjacent even positions on the baseplate (positions 1 and 2, 3 and 4, 5 and 6, or 7 and 8).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swapping:\u003c\/strong\u003e Module replacement can be executed without upsetting field input or output signals to the paired module and without removing power to other modules on the Modular Baseplate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Lengths:\u003c\/strong\u003e RJ-45 connections to Ethernet hubs, switches, or devices support cable lengths from 1 m (3.3 ft) up to 100 m (330 ft).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European EMC Directive 89\/336\/EEC, EN 50081-2, EN 50082-2, EN 61326 Annex A, CISPR 11 Class A, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Safety:\u003c\/strong\u003e UL\/UL-C listed for Class I, Groups A-D; Division 2; temperature code T4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Directive:\u003c\/strong\u003e CENELEC (DEMKO) certified as EEx nA IIC T4 for use in Zone 2 enclosure (Directive 94\/9\/EC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuropean Low Voltage Directive:\u003c\/strong\u003e 73\/23\/EEC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53705376334187,"sku":"FBM233 P0926GX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FBM233-P0926GX_001_1200x1200_23cc970b-0372-48c1-8f44-4a3b25ccf5f2.jpg?v=1786427584"},{"product_id":"foxboro-fcp280-rh924wa-field-control-processor-module","title":"Foxboro FCP280 RH924WA Field Control Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro FCP280 RH924WA Field Control Processor Module\u003c\/strong\u003e is a distributed, optionally fault-tolerant, field-mounted controller module designed for process control and alarming functions. Operating within the Foxboro Evo Process Automation System, the device executes regulatory, logic, timing, and sequential control schemes in conjunction with connected Fieldbus Modules (FBMs), while also managing data acquisition, alarm detection, and notification tasks. The \u003cstrong\u003eFoxboro FCP280\u003c\/strong\u003e connects to The Mesh control network via standard fiber optic or copper 100 Mbps Ethernet cables from baseplate-mounted network adapters. In this specific hardware configuration, the \u003cstrong\u003eRH924WA\u003c\/strong\u003e fiber adapter equips the module with ceramic LC connectors to interface via multimode fiber optic cabling.\u003c\/p\u003e\n\u003cp\u003eThe module interfaces with up to 128 Compact or standard 200 Series FBMs via a 2 Mbps HDLC fieldbus across four PIO channels (Expanded fieldbus). Alternatively, it supports up to 64 100 Series FBMs on a 268 Kbps HDLC fieldbus, with the remaining allocation made up of 200 Series modules up to the 128-module limit. Built with a rugged, non-vented die cast aluminum housing, the device is rated for Class G3 harsh environments and certified for field mounting in industrial process automation applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms regulatory, logic, timing, and sequential control along with data acquisition and alarm handling\u003c\/li\u003e\n\u003cli\u003eSupports up to 128 Compact\/standard 200 Series FBMs, or a combination of up to 64 100 Series FBMs and 200 Series FBMs\u003c\/li\u003e\n\u003cli\u003eConnects to The Mesh control network using RH924WA fiber adapters with dual LC connectors\u003c\/li\u003e\n\u003cli\u003eOffers optional fault-tolerant pairing with bit-for-bit message comparison across two processor modules\u003c\/li\u003e\n\u003cli\u003eIncludes self-hosting mode to boot and run control database from flash memory without host workstation connection\u003c\/li\u003e\n\u003cli\u003eSupports on-line image upgrade (OLUG) for fault-tolerant configurations\u003c\/li\u003e\n\u003cli\u003eIntegrated Liquid Crystal Display (LCD) shows letterbug, operational roles, and network statuses\u003c\/li\u003e\n\u003cli\u003eConstructed in die cast aluminum housing rated for Class G3 harsh environmental conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed process control in Foxboro Evo Process Automation Systems\u003c\/li\u003e\n\u003cli\u003eRegulatory, logic, timing, and sequential process loop execution\u003c\/li\u003e\n\u003cli\u003eField-mounted data acquisition, alarming, and Sequence Of Events (SOE) tracking\u003c\/li\u003e\n\u003cli\u003eInterface management for 100 Series and 200 Series Fieldbus Modules (FBMs)\u003c\/li\u003e\n\u003cli\u003eIntegration with third-party PLCs and serial devices via Field Device System Integrators (FDSI)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRH924YA\u003c\/td\u003e\n\u003ctd\u003eFCP280 Field Control Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRH924WA\u003c\/td\u003e\n\u003ctd\u003eFiber Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRH924UQ\u003c\/td\u003e\n\u003ctd\u003eCopper Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRH924YL\u003c\/td\u003e\n\u003ctd\u003eFCP280 Horizontal-Mounted Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRH924YF\u003c\/td\u003e\n\u003ctd\u003eFCP280 Vertical-Mounted Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRH928CV\u003c\/td\u003e\n\u003ctd\u003eTwinaxial Fieldbus Splitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRH924ZJ\u003c\/td\u003e\n\u003ctd\u003eRedundant Module Fieldbus Cable Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRH928CY\u003c\/td\u003e\n\u003ctd\u003eFieldbus Splitter and Termination Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRH924ZQ\u003c\/td\u003e\n\u003ctd\u003eTime Strobe Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro \/ Invensys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \u0026amp; Part\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Part Number\u003c\/td\u003e\n\u003ctd\u003eFCP280 (RH924YA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdapter Part Number\u003c\/td\u003e\n\u003ctd\u003eRH924WA (Fiber Adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor \u0026amp; Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eARM System on a Chip (SOC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMemory Size\u003c\/td\u003e\n\u003ctd\u003e128 MB SDRAM, 128 MB flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eError Detection\u003c\/td\u003e\n\u003ctd\u003eECC (single-bit detection\/correction, multi-bit detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigured Blocks Limit\u003c\/td\u003e\n\u003ctd\u003e8000 blocks maximum (7993 user-configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBlock Executions\u003c\/td\u003e\n\u003ctd\u003e16,000 blocks\/second maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMinimum BPC\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSequence Block Size\u003c\/td\u003e\n\u003ctd\u003e32 KB maximum per block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 Series FBMs\u003c\/td\u003e\n\u003ctd\u003eUp to 128 modules (up to 32 per Expanded fieldbus port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100 Series FBMs\u003c\/td\u003e\n\u003ctd\u003eUp to 64 modules maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Network\u003c\/td\u003e\n\u003ctd\u003eThe Mesh control network (100 Mbps Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFieldbus Type\u003c\/td\u003e\n\u003ctd\u003eHDLC (2 Mbps for 200 Series, 268 Kbps for 100 Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNetwork Fiber Cable\u003c\/td\u003e\n\u003ctd\u003eMMF 62.5\/125 um plenum (up to 2 km max distance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNetwork Connectors\u003c\/td\u003e\n\u003ctd\u003eTwo ceramic LC connectors on adapter end, MT-RJ on switch end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V dc typical (redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eConsumption\u003c\/td\u003e\n\u003ctd\u003e8.5 W maximum (per non-fault-tolerant module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC (-40 to 158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (Noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e-300 to +3,000 m operating; -300 to +12,000 m storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eContamination Class\u003c\/td\u003e\n\u003ctd\u003eClass G3 (Harsh) per ISA Standard S71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e0.5 g (5 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e105 mm x 51.8 mm x 147 mm (116 mm H with lugs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMass \/ Weight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg maximum (single module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAdapter \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Cable Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Adapter (RH924WA)\u003c\/td\u003e\n\u003ctd\u003eControl Network Connection to Mesh Switch\u003c\/td\u003e\n\u003ctd\u003eDual Ceramic LC connectors (to adapter), MT-RJ (to switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus Ports 1 - 4\u003c\/td\u003e\n\u003ctd\u003eFour PIO channels (Expanded fieldbus to FBM baseplates)\u003c\/td\u003e\n\u003ctd\u003eHDLC interface (2 Mbps or 268 Kbps per port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Power A \/ B\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 V dc power input on baseplate\u003c\/td\u003e\n\u003ctd\u003eDirect baseplate power connection terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Mounting:\u003c\/strong\u003e Mount the FCP280 in dedicated, keyed slots on vertical (RH924YF) or horizontal (RH924YL) DIN rail baseplates. Vertical baseplates are recommended for optimized convection cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault-Tolerant Setup:\u003c\/strong\u003e Install fault-tolerant module pairs in adjacent FCP280 slots on the baseplate to enable direct internal interconnecting communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Cabling:\u003c\/strong\u003e Connect the RH924WA fiber adapter to The Mesh Ethernet switches using 62.5\/125 um multimode fiber optic cables up to a maximum distance of 2 km.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldbus Wiring:\u003c\/strong\u003e Ensure each Fieldbus port on the baseplate is dedicated exclusively to either a 2 Mbps HDLC fieldbus (200 Series) or 268 Kbps HDLC fieldbus (100 Series). The cable length for each Expanded fieldbus segment must not exceed 60 m without isolation\/extension devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e European EMC Directive 2004\/108\/EC meeting EN 61326-1, CISPR 11 Class A, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, and IEC 61000-4-8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Safety:\u003c\/strong\u003e UL\/UL-C listed for Class I, Groups A-D; Division 2 enclosure-based systems; Class 2 circuits per NEC Article 725 \/ CSA C22.1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Directive:\u003c\/strong\u003e European Low Voltage Directive 2006\/95\/EC and ATEX Directive 94\/9\/EC certified Ex nA IIC T4 Gc (DEMKO) for Zone 2 classified areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity Certification:\u003c\/strong\u003e Wurldtech Achilles Certification Level 1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53706873274731,"sku":"FCP280 RH924WA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FCP280-RH924WA_001_1200x1200_c1d36c95-bcab-4828-b855-e0cdef6bde80.jpg?v=1786458975"},{"product_id":"foxboro-p0926tm-i-a-series-power-cable-assembly","title":"Foxboro P0926TM I\/A Series Power Cable Assembly","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Foxboro P0926TM is a power cable assembly designed for providing AC input power to external power supplies in I\/A Series system hardware installations. The \u003cstrong\u003eFoxboro P0926TM\u003c\/strong\u003e power cable assembly features a 122 cm (48 in) length and a 120 V AC input rating, connecting power sources directly to the FPS400-24 power supply (P0922YU) used with I-Series industrially hardened switches.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e120 V AC input power cable assembly\u003c\/li\u003e\n\u003cli\u003e122 cm (48 in) total length\u003c\/li\u003e\n\u003cli\u003eDesigned for use with the FPS400-24 power supply (P0922YU)\u003c\/li\u003e\n\u003cli\u003eComponent of the Foxboro I\/A Series MESH control network equipment hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFoxboro I\/A Series control system hardware installations\u003c\/li\u003e\n\u003cli\u003ePowering FPS400-24 power supplies (P0922YU) for I-Series industrially hardened managed switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Invensys)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e120 V AC input Power cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Power Supply\u003c\/td\u003e\n\u003ctd\u003eP0922YU (FPS400-24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e122 cm (48 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure power supply wiring methods comply with governing electrical codes and authority having jurisdiction for Class I, Div. 2 installations.\u003c\/li\u003e\n\u003cli\u003eUtilize proper grounding techniques as mandated by local and national electrical safety codes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53715817857387,"sku":"P0926TM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/P0926TM_001_1200x1200_c224cd13-74eb-475e-9e23-babe0a5e7deb.jpg?v=1786596868"}],"url":"https:\/\/www.plcprotech.com\/collections\/foxboro.oembed?page=3","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}