{"title":"GE VersaMax","description":"\u003cp\u003eGE VersaMax is a highly versatile and scalable automation platform designed to serve as both a standalone PLC and high-density distributed I\/O. The architecture is characterized by its \"snap-together\" modularity, featuring compact CPUs, diverse I\/O types, and flexible expansion carriers. Technical characteristics include high-density channel configurations, integrated diagnostic LEDs, and broad compatibility with \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/ge-rx3i-rx7i-pacsystems\"\u003ePACSystems RX3i\u003c\/a\u003e networks. Functionally, VersaMax provides a cost-effective solution for small-to-medium control tasks and remote I\/O stations, delivering reliable performance in packaging, water treatment, and food processing. Its ability to combine discrete and analog I\/O within a single footprint allows for customized control strategies that maximize space efficiency and system throughput in modern industrial automation environments.\u003c\/p\u003e","products":[{"product_id":"ge-fanuc-versamax-ic200alg240-8-channel-analog-input-module","title":"GE Fanuc VersaMax IC200ALG240 8-Channel Analog Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200ALG240 (IC200-ALG-240)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 8-channel analog input module designed for the GE VersaMax I\/O family.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is engineered to interface with voltage-based field devices,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a unipolar input range of 0 to +10 VDC.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is an essential component for capturing data from various sensors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as pressure transducers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eflow meters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand level sensors that output standard voltage signals.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWith its 12-bit resolution,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200ALG240\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffers the precision required for general-purpose industrial monitoring and control.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts modular,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecompact design facilitates decentralized I\/O architectures,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for efficient data acquisition in applications ranging from building automation to factory floor machinery control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe IC200ALG240 features eight single-ended input channels that share a common return.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a 12-bit Analog-to-Digital Converter (ADC),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich translates the 0-10 VDC signal into 4,\u003c\/span\u003e\u003cspan class=\"\"\u003e000 digital counts (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e0025 V per bit).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs part of the VersaMax ecosystem,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module snaps onto a terminal base (sold separately),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting \"Permanent Wiring\" and hot-swappable maintenance.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module includes active diagnostics to monitor the health of the internal circuitry and the presence of the required 24 VDC user power.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs provide \"OK\" and \"User Power\" status for immediate visual confirmation of module health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG240\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage (Unipolar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Single-ended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit (0 to 4000 counts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5% of full scale (at 25 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 500 kOhms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 ms for all 8 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 6.68 x 2.63 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes this module require external power for the input channels?\u003c\/strong\u003e\u003cspan class=\"\"\u003eYes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200ALG240 requires an external 24 VDC power supply (User Power) to operate the analog-to-digital conversion circuitry.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf this power is absent,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module will report a \"User Power Lost\" fault and all input data will go to zero.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan I connect current-based sensors (4-20 mA) to this module?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe IC200ALG240 is natively a voltage-input module.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTo read 4-20 mA signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eyou would typically use an external 250-Ohm precision resistor across the input terminals to convert the current to a 1-5 VDC signal,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor ideally,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eutilize the dedicated current input module,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200ALG262\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the update rate for the 8 channels?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe module is highly efficient,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eupdating all eight channels in approximately 2 ms.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis makes it suitable for processes requiring relatively fast feedback loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as certain hydraulic pressure or valve position monitoring tasks.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Common Return:\u003c\/strong\u003e\u003cspan\u003e Since the 8 channels share a common return,\u003c\/span\u003e\u003cspan\u003e ensure that all field sensors are compatible with a common-ground architecture.\u003c\/span\u003e\u003cspan\u003e If your sensors require galvanic isolation between channels to prevent ground loops,\u003c\/span\u003e\u003cspan\u003e you must use signal isolators or an isolated analog input module.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding for Voltage Signals:\u003c\/strong\u003e\u003cspan\u003e Voltage signals are susceptible to electromagnetic interference (EMI).\u003c\/span\u003e\u003cspan\u003e Always use high-quality shielded twisted-pair cabling.\u003c\/span\u003e\u003cspan\u003e Connect the shield to the terminal base ground point and leave it floating at the sensor end to avoid creating ground loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Keying:\u003c\/strong\u003e\u003cspan\u003e When installing the module,\u003c\/span\u003e\u003cspan\u003e ensure the terminal base is correctly keyed for the \"Analog Input\" position.\u003c\/span\u003e\u003cspan\u003e This mechanical safety feature prevents the accidental insertion of a different module type,\u003c\/span\u003e\u003cspan\u003e protecting the internal electronics of the IC200ALG240 from incorrect voltage levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695407821163,"sku":"IC200ALG240","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg240-versamax-analog-input-module-5auojj5jiq3_1cd172a9-cb81-4b65-8c43-134e6d4d19b1.jpg?v=1766134950"},{"product_id":"ge-fanuc-versamax-ic200alg620-4-channel-rtd-input-module","title":"GE Fanuc VersaMax IC200ALG620 4-Channel RTD Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-153\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eIC200ALG620 (IC200-ALG-620)\u003c\/strong\u003e\u003cspan class=\"citation-153 citation-end-153\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, 4-channel analog input module designed specifically for Resistance Temperature Detectors (RTD).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-152 citation-end-152\"\u003ePart of the GE VersaMax I\/O family, this module provides direct interfacing for temperature sensors without the need for external signal transmitters.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-151 citation-end-151\"\u003eIt is engineered to support a wide array of RTD types, including Platinum, Nickel, and Copper sensors, as well as resistance inputs.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWith its 16-bit resolution, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG620\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an essential component for high-accuracy thermal monitoring in climate control systems, chemical reactor vessels, and food processing pasteurization loops. Its compact, modular design allows for decentralized placement, reducing expensive specialized wiring runs by digitizing temperature data close to the source.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module supports 2-wire, 3-wire, and 4-wire RTD configurations, providing maximum flexibility for different lead-wire compensation requirements. It features a 16-bit A\/D converter that delivers exceptional granularity, allowing the controller to detect minute thermal shifts. The VersaMax architecture enables the electronics to reside on a terminal base (sold separately), which supports \"Permanent Wiring\"—meaning the module can be hot-swapped without disturbing the sensor field wiring. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG620\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes internal diagnostics to detect \"Open Wire\" or \"Short Circuit\" conditions on a per-channel basis, with front-facing LED indicators for \"OK\" and \"User Power\" status.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG620\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD (Pt, Ni, Cu) \/ Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTD Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Cu10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResistance Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 500 Ohms \/ 0 to 3000 Ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.1% to 0.5% (depending on sensor type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 ms to 80 ms per channel (configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support both Celsius and Fahrenheit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module reports data in counts or tenths of a degree. The conversion to Celsius or Fahrenheit is typically handled in the PLC hardware configuration (Proficy Machine Edition) or via a scaling block in the logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of using 3-wire or 4-wire wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-150 citation-end-150\"\u003e2-wire setups are prone to errors caused by the resistance of the lead wires.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e3-wire wiring (the industrial standard) compensates for lead resistance, while 4-wire wiring provides the highest precision by completely eliminating lead-wire resistance effects from the measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different RTD types on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Through the software configuration, each of the four channels can be independently set to a different RTD type (e.g., Channel 1 as Pt100, Channel 2 as a 0-500 Ohm resistance input).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module requires a terminal base such as the IC200TBT002 (Barrier style) or IC200TBP002 (Spring style). Ensure the base is correctly keyed to the \"Analog\" position to prevent incorrect module insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLead-Wire Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor 3-wire and 4-wire installations, ensure all lead wires are of the same gauge and length. Significant differences in wire resistance between the \"Excitation\" and \"Sense\" lines can introduce a temperature offset that the module cannot automatically cancel out.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-149\"\u003e\u003c\/span\u003e\u003cstrong\u003eShielding for Low-Voltage Signals:\u003c\/strong\u003e\u003cspan class=\"citation-149 citation-end-149\"\u003e\u003cspan\u003e \u003c\/span\u003eRTD signals are millivolt-level and highly sensitive to noise.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAlways use shielded twisted-pair cable. Terminate the shield at the PLC terminal base ground and never ground the shield at the sensor end to avoid ground loops that could cause \"Signal Wander.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695413916011,"sku":"IC200ALG620","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg620-analog-input-rtd-module-z3lcbpwomve_d7baa4c8-73e1-424b-9456-6288ea6ae52d.jpg?v=1766135166"},{"product_id":"ge-fanuc-versamax-ic200alg322-4-channel-analog-output-module-current","title":"GE Fanuc VersaMax IC200ALG322 4-Channel Analog Output Module (Current)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322 (IC200-ALG-322)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, 4-channel analog output module within the GE VersaMax I\/O family. It is specifically engineered to provide sourcing current signals, supporting both 0 to 20 mA and 4 to 20 mA ranges. This module is the industry standard for controlling current-driven actuators, such as variable speed drives (VFDs), proportional valves, and industrial dampers. Its 12-bit resolution ensures smooth and accurate control loops, while its compact, modular design allows for decentralized I\/O placement in wastewater treatment, oil and gas, and pharmaceutical manufacturing facilities. As a mission-critical component, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that digital control commands from the CPU are translated into precise physical movements in the field.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module features four independent current-sourcing channels that share a common return. It is designed to be hosted on a VersaMax terminal base, which facilitates \"Permanent Wiring\"—allowing the electronics to be replaced without disconnecting field wires. The IC200ALG322 includes sophisticated internal diagnostics to monitor the health of the D\/A converters and the presence of user-supplied 24 VDC power. Front-panel LED indicators provide immediate visual feedback: \"OK\" indicates the module is functional, while \"User Power\" confirms that the external 24 VDC required for the current loops is present.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG322\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA \/ 4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit (0 to 4000 counts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5% of full scale (at 25 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 mA (Max) from 24 VDC supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 6.68 x 2.63 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the module for 4-20 mA instead of 0-20 mA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe range selection is handled via the software configuration in Proficy Machine Edition (or PAC Machine Edition). Once configured, the module automatically scales the internal counts (0-4000) to the selected physical current range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power for the loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200ALG322 requires an external +24 VDC \"User Power\" supply. This power is used to drive the current through the field loops. If this power is missing, the outputs will remain at 0 mA regardless of the PLC's logic state.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the output if the PLC is switched to STOP mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe behavior is configurable. You can set the channels to \"Hold Last State\" or \"Output Default.\" In \"Output Default\" mode, you can specify a safe current value (e.g., 4 mA) that the module will output if communication with the CPU is lost.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Resistance Limits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200ALG322 can drive a maximum load resistance of 850 Ohms at 24 VDC. Ensure that the combined resistance of your field device and the interconnecting cable does not exceed this value, otherwise, the module will be unable to reach the full 20 mA output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCurrent signals are more robust than voltage signals, but shielding is still essential for high-precision loops. Terminate the cable shield at the terminal base ground and ensure it is not grounded at the actuator end to prevent ground loop interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swapping Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile VersaMax supports hot-swapping, always ensure the \"User Power\" is switched off or the field loop is in a safe manual override before pulling the module. This prevents unexpected actuator movement or electrical arcing during the swap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695415030123,"sku":"IC200ALG322","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg322-analog-output-module-wwqx5cwllyo_c3efeeb5-348e-419a-858f-540c206bffa4.jpg?v=1766135213"},{"product_id":"ge-fanuc-ic200alg264-analog-current-input-module","title":"GE Fanuc IC200ALG264 Analog Current Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-138\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eIC200ALG264 (IC200-ALG-264)\u003c\/strong\u003e\u003cspan class=\"citation-138 citation-end-138\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, 15-channel analog input module from the GE VersaMax series, specifically designed for precision monitoring of current signals.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is engineered to accept unipolar current inputs ranging from 0 to 20 mA or 4 to 20 mA, making it a critical component for processing feedback from transmitters in chemical plants, water treatment facilities, and HVAC systems. By offering 15 channels in a single compact footprint, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG264\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaximizes panel space efficiency while providing 12-bit resolution for accurate data acquisition. Its seamless integration with VersaMax CPUs and Network Interface Units (NIUs) ensures high-speed data throughput and robust performance in distributed I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module features a high-density architecture where 15 channels share a common return, optimized for space-constrained installations. It utilizes a 12-bit A\/D converter, providing 4,000 counts over the signal range.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-137 citation-end-137\"\u003eThe module is \"Hot-Swappable\" when used with appropriate VersaMax terminal bases, allowing for maintenance without system shutdown.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-136 citation-end-136\"\u003eBuilt-in diagnostics include \"Open Wire\" detection for 4-20 mA mode and monitoring of the user-supplied 24 VDC power, with front-facing LED indicators for \"OK\" and \"User Power\" status to simplify field troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG264\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent (Unipolar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 (Single-ended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA \/ 4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit (4,000 counts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.25% of full scale (at 25 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 ms for all 15 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external 24 VDC to function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200ALG264 requires an external 24 VDC power supply to power the analog-to-digital conversion circuitry. This power is connected via the terminal base. If the \"User Power\" LED is not illuminated, the module will report zero or under-range values to the CPU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 15-channel \"Common Return\" affect wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike 8-channel isolated modules, all 15 channels on the IC200ALG264 share a single common return path. This means all field transmitters must be compatible with a shared ground system. For loops requiring full galvanic isolation between channels, a different module or external signal isolators should be used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a 4-20 mA wire is broken?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn 4-20 mA mode, the module provides a low-range diagnostic. If the current drops below approximately 3.5 mA, the PLC will typically report a \"Low Alarm\" or \"Open Wire\" fault for that specific channel, allowing for immediate maintenance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis high-density module must be paired with a compatible terminal base, such as the IC200TBT002 (Barrier style) or IC200TBP002 (Spring style). Ensure the base is keyed correctly to prevent accidental insertion of digital modules into the analog slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding for High-Density I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith 15 analog signals in close proximity, crosstalk and EMI are potential risks. Use high-quality shielded twisted-pair cabling and ensure the shields are terminated at the PLC end to a dedicated earth ground bar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Power Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the field transmitters are \"2-wire\" types (loop-powered), ensure your external 24 VDC power supply has sufficient amperage to power all 15 loops simultaneously, plus the module's own power requirement (approx. 50 mA).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695419486571,"sku":"IC200ALG264","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg264-analog-current-input-module-mxzzudnxg31_e1607b26-0523-4ea4-b508-394be5b33c7b.jpg?v=1766135354"},{"product_id":"ge-fanuc-versamax-ic200alg320-analog-output-module","title":"GE Fanuc VersaMax IC200ALG320 Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-128\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eIC200ALG320 (IC200-ALG-320)\u003c\/strong\u003e\u003cspan class=\"citation-128 citation-end-128\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, 4-channel analog output module from the GE VersaMax family.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed to provide unipolar voltage signals ranging from 0 to +10 VDC to control proportional valves, variable speed drives, and other actuators in industrial automation systems. Known for its compact footprint and ease of integration, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG320\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverts digital data from the CPU or Network Interface Unit (NIU) into stable, low-noise analog signals. Its modular design allows for \"Hot-Swapping\" and easy DIN-rail mounting, making it a reliable choice for decentralized control in HVAC, water treatment, and light manufacturing applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module features a 12-bit resolution, ensuring granular control over the output signal. Each of the four channels is independent, although they share a common ground. The VersaMax architecture separates the module electronics from the field wiring via a terminal base (sold separately), which allows for permanent wiring and simplified maintenance.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-127 citation-end-127\"\u003eThe module includes internal diagnostics to monitor the health of the D\/A converters and provides LED status indicators for \"OK\" and \"User Power\" to facilitate rapid on-site troubleshooting.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG320\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage (Unipolar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit (0 to 4095 counts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5% of full scale (at 25 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 4 ms for all 4 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 6.68 x 2.63 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200ALG320 requires an external +24 VDC power supply to drive the analog output circuits. This power is usually supplied through the terminal base. If the \"User Power\" LED is off, the analog outputs will not function even if the PLC is in Run mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Default\" behavior if the PLC stops communicating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring configuration in Proficy Machine Edition, you can set the \"Hold Last State\" or \"Output Default\" behavior. This ensures that if communication is lost, the 0-10V signal either stays at its current value or drops to a safe predefined voltage (usually 0V).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for 4-20mA current loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200ALG320 is a voltage-only module (0-10V). For current loop applications, you would need the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG321\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(which is the 0-20mA\/4-20mA equivalent).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Shielding:\u003c\/strong\u003e\u003cspan class=\"citation-126 citation-end-126\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalog signals are highly susceptible to electromagnetic interference (EMI).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAlways use shielded twisted-pair (STP) cabling. The shield should be grounded at the PLC end (the terminal base) and left floating at the actuator end to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module is compatible with several terminal bases, such as the IC200TBT001 (Barrier style) or IC200TBP001 (Spring style). Ensure the base is correctly keyed to the \"Analog Output\" position to prevent the insertion of a different module type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the input impedance of the receiving device (e.g., a VFD) is at least 2 kOhms. Connecting a load with too low an impedance will cause the voltage to drop and may trigger a thermal overload within the module's output stage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695420305771,"sku":"IC200ALG320","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg320-versamax-analog-output-module-pr3ohiktwjj_b726736e-011b-4782-8e11-16d6e7be3b4a.jpg?v=1766135387"},{"product_id":"ge-fanuc-versamax-ic200mdl740e-digital-output-module","title":"GE Fanuc VersaMax IC200MDL740E Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200MDL740E (IC200-MDL-740E) \u003c\/strong\u003eis a high-density, 16-point digital output module from the GE VersaMax I\/O family. Operating at 24 VDC, this module utilizes positive logic (Sourcing) transistor outputs, designed to drive various industrial loads such as solenoid valves, motor starters, and indicator lights. The \"E\" suffix signifies a specific hardware revision, often incorporating improved internal component heat dissipation or updated manufacturing standards. As a modular \"plug-and-play\" component, the IC200MDL740E is a staple in compact automation systems where space efficiency and reliable switching are paramount, offering seamless integration with VersaMax CPUs or Network Interface Units (NIUs) in distributed I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe VersaMax I\/O architecture allows for hot-insertion into a variety of terminal bases (sold separately). The IC200MDL740E features 16 independent output points divided into two groups of eight, providing flexibility in power distribution. Each output is equipped with short-circuit protection and thermal shutdown to prevent module damage during field-side faults.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-114 citation-end-114\"\u003eThe module provides LED status indicators for each point, mounted on the top of the carrier, enabling rapid visual diagnostics without the need for a programming terminal.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200MDL740E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Transistor (Sourcing\/Positive Logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Points (2 groups of 8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per point (Max 4 A per group)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 ms (Off to On \/ On to Off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 VAC continuous (between field\/logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 6.68 x 2.63 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between \"Positive Logic\" and \"Negative Logic\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-113 citation-end-113\"\u003eThe IC200MDL740E is a \"Sourcing\" (Positive Logic) module, meaning it switches the positive side of the 24 VDC supply to the load.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe load must then be connected to the common ground (OV). This is the most common standard in North American and European industrial control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different VersaMax modules on the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, VersaMax is a highly modular system. You can mix digital, analog, and specialty modules (like the IC200MDL740E) on the same expansion rack, provided the total power consumption does not exceed the capacity of the power supply module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. VersaMax modules are \"carriers\" that must be plugged into a base (such as the IC200TBT001 or IC200TBP001). This design allows for \"Permanent Wiring,\" where the module can be replaced without disturbing the field wires.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-112\"\u003e\u003c\/span\u003e\u003cstrong\u003eExternal Suppression:\u003c\/strong\u003e\u003cspan class=\"citation-112 citation-end-112\"\u003e\u003cspan\u003e \u003c\/span\u003eWhen driving inductive loads (e.g., solenoids or relay coils), it is highly recommended to install a suppression diode (flyback diode) across the load.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhile the module has internal protection, external suppression prevents electromagnetic noise from interfering with nearby analog signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent De-rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile each point can handle 0.5 A, be mindful of the \"Group Total.\" For the IC200MDL740E, the total current for each group of 8 points should not exceed 4 Amps. If your application requires all 16 points to be \"On\" simultaneously at high currents, ensure the enclosure has adequate ventilation to manage the heat generated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swapping Safety:\u003c\/strong\u003e\u003cspan class=\"citation-111 citation-end-111\"\u003e\u003cspan\u003e \u003c\/span\u003eVersaMax supports \"Hot-Swapping\" (inserting\/removing modules under power) if the terminal base is properly installed.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eHowever, always ensure the field-side 24 VDC power is disconnected or the load is in a safe state to prevent accidental machine movement during the swap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695421649259,"sku":"IC200MDL740E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic200mdl740e-output-modules-xch50inxgux_533d557a-d9e0-42bf-a7e4-104f6c06f3fe.jpg?v=1766135438"}],"url":"https:\/\/www.plcprotech.com\/collections\/ge-versamax.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}