{"title":"GE VersaMax","description":"\u003cp\u003eGE VersaMax is a highly versatile and scalable automation platform designed to serve as both a standalone PLC and high-density distributed I\/O. The architecture is characterized by its \"snap-together\" modularity, featuring compact CPUs, diverse I\/O types, and flexible expansion carriers. Technical characteristics include high-density channel configurations, integrated diagnostic LEDs, and broad compatibility with \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/ge-rx3i-rx7i-pacsystems\"\u003ePACSystems RX3i\u003c\/a\u003e networks. Functionally, VersaMax provides a cost-effective solution for small-to-medium control tasks and remote I\/O stations, delivering reliable performance in packaging, water treatment, and food processing. Its ability to combine discrete and analog I\/O within a single footprint allows for customized control strategies that maximize space efficiency and system throughput in modern industrial automation environments.\u003c\/p\u003e","products":[{"product_id":"ge-fanuc-versamax-ic200alg240-8-channel-analog-input-module","title":"GE Fanuc VersaMax IC200ALG240 8-Channel Analog Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200ALG240 (IC200-ALG-240)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 8-channel analog input module designed for the GE VersaMax I\/O family.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is engineered to interface with voltage-based field devices,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a unipolar input range of 0 to +10 VDC.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is an essential component for capturing data from various sensors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as pressure transducers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eflow meters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand level sensors that output standard voltage signals.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWith its 12-bit resolution,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200ALG240\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffers the precision required for general-purpose industrial monitoring and control.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts modular,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecompact design facilitates decentralized I\/O architectures,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for efficient data acquisition in applications ranging from building automation to factory floor machinery control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe IC200ALG240 features eight single-ended input channels that share a common return.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a 12-bit Analog-to-Digital Converter (ADC),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich translates the 0-10 VDC signal into 4,\u003c\/span\u003e\u003cspan class=\"\"\u003e000 digital counts (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e0025 V per bit).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs part of the VersaMax ecosystem,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module snaps onto a terminal base (sold separately),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting \"Permanent Wiring\" and hot-swappable maintenance.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module includes active diagnostics to monitor the health of the internal circuitry and the presence of the required 24 VDC user power.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs provide \"OK\" and \"User Power\" status for immediate visual confirmation of module health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG240\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage (Unipolar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Single-ended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit (0 to 4000 counts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5% of full scale (at 25 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 500 kOhms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 ms for all 8 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 6.68 x 2.63 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes this module require external power for the input channels?\u003c\/strong\u003e\u003cspan class=\"\"\u003eYes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200ALG240 requires an external 24 VDC power supply (User Power) to operate the analog-to-digital conversion circuitry.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf this power is absent,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module will report a \"User Power Lost\" fault and all input data will go to zero.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan I connect current-based sensors (4-20 mA) to this module?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe IC200ALG240 is natively a voltage-input module.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTo read 4-20 mA signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eyou would typically use an external 250-Ohm precision resistor across the input terminals to convert the current to a 1-5 VDC signal,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor ideally,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eutilize the dedicated current input module,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200ALG262\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the update rate for the 8 channels?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe module is highly efficient,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eupdating all eight channels in approximately 2 ms.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis makes it suitable for processes requiring relatively fast feedback loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as certain hydraulic pressure or valve position monitoring tasks.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Common Return:\u003c\/strong\u003e\u003cspan\u003e Since the 8 channels share a common return,\u003c\/span\u003e\u003cspan\u003e ensure that all field sensors are compatible with a common-ground architecture.\u003c\/span\u003e\u003cspan\u003e If your sensors require galvanic isolation between channels to prevent ground loops,\u003c\/span\u003e\u003cspan\u003e you must use signal isolators or an isolated analog input module.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding for Voltage Signals:\u003c\/strong\u003e\u003cspan\u003e Voltage signals are susceptible to electromagnetic interference (EMI).\u003c\/span\u003e\u003cspan\u003e Always use high-quality shielded twisted-pair cabling.\u003c\/span\u003e\u003cspan\u003e Connect the shield to the terminal base ground point and leave it floating at the sensor end to avoid creating ground loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Keying:\u003c\/strong\u003e\u003cspan\u003e When installing the module,\u003c\/span\u003e\u003cspan\u003e ensure the terminal base is correctly keyed for the \"Analog Input\" position.\u003c\/span\u003e\u003cspan\u003e This mechanical safety feature prevents the accidental insertion of a different module type,\u003c\/span\u003e\u003cspan\u003e protecting the internal electronics of the IC200ALG240 from incorrect voltage levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695407821163,"sku":"IC200ALG240","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg240-versamax-analog-input-module-5auojj5jiq3_1cd172a9-cb81-4b65-8c43-134e6d4d19b1.jpg?v=1766134950"},{"product_id":"ge-fanuc-versamax-ic200alg620-4-channel-rtd-input-module","title":"GE Fanuc VersaMax IC200ALG620 4-Channel RTD Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-153\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eIC200ALG620 (IC200-ALG-620)\u003c\/strong\u003e\u003cspan class=\"citation-153 citation-end-153\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, 4-channel analog input module designed specifically for Resistance Temperature Detectors (RTD).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-152 citation-end-152\"\u003ePart of the GE VersaMax I\/O family, this module provides direct interfacing for temperature sensors without the need for external signal transmitters.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-151 citation-end-151\"\u003eIt is engineered to support a wide array of RTD types, including Platinum, Nickel, and Copper sensors, as well as resistance inputs.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWith its 16-bit resolution, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG620\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an essential component for high-accuracy thermal monitoring in climate control systems, chemical reactor vessels, and food processing pasteurization loops. Its compact, modular design allows for decentralized placement, reducing expensive specialized wiring runs by digitizing temperature data close to the source.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module supports 2-wire, 3-wire, and 4-wire RTD configurations, providing maximum flexibility for different lead-wire compensation requirements. It features a 16-bit A\/D converter that delivers exceptional granularity, allowing the controller to detect minute thermal shifts. The VersaMax architecture enables the electronics to reside on a terminal base (sold separately), which supports \"Permanent Wiring\"—meaning the module can be hot-swapped without disturbing the sensor field wiring. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG620\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes internal diagnostics to detect \"Open Wire\" or \"Short Circuit\" conditions on a per-channel basis, with front-facing LED indicators for \"OK\" and \"User Power\" status.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG620\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD (Pt, Ni, Cu) \/ Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTD Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Cu10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResistance Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 500 Ohms \/ 0 to 3000 Ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.1% to 0.5% (depending on sensor type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 ms to 80 ms per channel (configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support both Celsius and Fahrenheit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module reports data in counts or tenths of a degree. The conversion to Celsius or Fahrenheit is typically handled in the PLC hardware configuration (Proficy Machine Edition) or via a scaling block in the logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of using 3-wire or 4-wire wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-150 citation-end-150\"\u003e2-wire setups are prone to errors caused by the resistance of the lead wires.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e3-wire wiring (the industrial standard) compensates for lead resistance, while 4-wire wiring provides the highest precision by completely eliminating lead-wire resistance effects from the measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different RTD types on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Through the software configuration, each of the four channels can be independently set to a different RTD type (e.g., Channel 1 as Pt100, Channel 2 as a 0-500 Ohm resistance input).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module requires a terminal base such as the IC200TBT002 (Barrier style) or IC200TBP002 (Spring style). Ensure the base is correctly keyed to the \"Analog\" position to prevent incorrect module insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLead-Wire Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor 3-wire and 4-wire installations, ensure all lead wires are of the same gauge and length. Significant differences in wire resistance between the \"Excitation\" and \"Sense\" lines can introduce a temperature offset that the module cannot automatically cancel out.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-149\"\u003e\u003c\/span\u003e\u003cstrong\u003eShielding for Low-Voltage Signals:\u003c\/strong\u003e\u003cspan class=\"citation-149 citation-end-149\"\u003e\u003cspan\u003e \u003c\/span\u003eRTD signals are millivolt-level and highly sensitive to noise.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAlways use shielded twisted-pair cable. Terminate the shield at the PLC terminal base ground and never ground the shield at the sensor end to avoid ground loops that could cause \"Signal Wander.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695413916011,"sku":"IC200ALG620","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg620-analog-input-rtd-module-z3lcbpwomve_d7baa4c8-73e1-424b-9456-6288ea6ae52d.jpg?v=1766135166"},{"product_id":"ge-fanuc-versamax-ic200alg322-4-channel-analog-output-module-current","title":"GE Fanuc VersaMax IC200ALG322 4-Channel Analog Output Module (Current)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322 (IC200-ALG-322)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, 4-channel analog output module within the GE VersaMax I\/O family. It is specifically engineered to provide sourcing current signals, supporting both 0 to 20 mA and 4 to 20 mA ranges. This module is the industry standard for controlling current-driven actuators, such as variable speed drives (VFDs), proportional valves, and industrial dampers. Its 12-bit resolution ensures smooth and accurate control loops, while its compact, modular design allows for decentralized I\/O placement in wastewater treatment, oil and gas, and pharmaceutical manufacturing facilities. As a mission-critical component, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that digital control commands from the CPU are translated into precise physical movements in the field.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module features four independent current-sourcing channels that share a common return. It is designed to be hosted on a VersaMax terminal base, which facilitates \"Permanent Wiring\"—allowing the electronics to be replaced without disconnecting field wires. The IC200ALG322 includes sophisticated internal diagnostics to monitor the health of the D\/A converters and the presence of user-supplied 24 VDC power. Front-panel LED indicators provide immediate visual feedback: \"OK\" indicates the module is functional, while \"User Power\" confirms that the external 24 VDC required for the current loops is present.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG322\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA \/ 4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit (0 to 4000 counts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5% of full scale (at 25 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 mA (Max) from 24 VDC supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 6.68 x 2.63 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the module for 4-20 mA instead of 0-20 mA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe range selection is handled via the software configuration in Proficy Machine Edition (or PAC Machine Edition). Once configured, the module automatically scales the internal counts (0-4000) to the selected physical current range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power for the loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200ALG322 requires an external +24 VDC \"User Power\" supply. This power is used to drive the current through the field loops. If this power is missing, the outputs will remain at 0 mA regardless of the PLC's logic state.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the output if the PLC is switched to STOP mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe behavior is configurable. You can set the channels to \"Hold Last State\" or \"Output Default.\" In \"Output Default\" mode, you can specify a safe current value (e.g., 4 mA) that the module will output if communication with the CPU is lost.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Resistance Limits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200ALG322 can drive a maximum load resistance of 850 Ohms at 24 VDC. Ensure that the combined resistance of your field device and the interconnecting cable does not exceed this value, otherwise, the module will be unable to reach the full 20 mA output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCurrent signals are more robust than voltage signals, but shielding is still essential for high-precision loops. Terminate the cable shield at the terminal base ground and ensure it is not grounded at the actuator end to prevent ground loop interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swapping Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile VersaMax supports hot-swapping, always ensure the \"User Power\" is switched off or the field loop is in a safe manual override before pulling the module. This prevents unexpected actuator movement or electrical arcing during the swap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695415030123,"sku":"IC200ALG322","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg322-analog-output-module-wwqx5cwllyo_c3efeeb5-348e-419a-858f-540c206bffa4.jpg?v=1766135213"},{"product_id":"ge-fanuc-ic200alg264-analog-current-input-module","title":"GE Fanuc IC200ALG264 Analog Current Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-138\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eIC200ALG264 (IC200-ALG-264)\u003c\/strong\u003e\u003cspan class=\"citation-138 citation-end-138\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, 15-channel analog input module from the GE VersaMax series, specifically designed for precision monitoring of current signals.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is engineered to accept unipolar current inputs ranging from 0 to 20 mA or 4 to 20 mA, making it a critical component for processing feedback from transmitters in chemical plants, water treatment facilities, and HVAC systems. By offering 15 channels in a single compact footprint, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG264\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaximizes panel space efficiency while providing 12-bit resolution for accurate data acquisition. Its seamless integration with VersaMax CPUs and Network Interface Units (NIUs) ensures high-speed data throughput and robust performance in distributed I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module features a high-density architecture where 15 channels share a common return, optimized for space-constrained installations. It utilizes a 12-bit A\/D converter, providing 4,000 counts over the signal range.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-137 citation-end-137\"\u003eThe module is \"Hot-Swappable\" when used with appropriate VersaMax terminal bases, allowing for maintenance without system shutdown.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-136 citation-end-136\"\u003eBuilt-in diagnostics include \"Open Wire\" detection for 4-20 mA mode and monitoring of the user-supplied 24 VDC power, with front-facing LED indicators for \"OK\" and \"User Power\" status to simplify field troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG264\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent (Unipolar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 (Single-ended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA \/ 4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit (4,000 counts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.25% of full scale (at 25 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 ms for all 15 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external 24 VDC to function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200ALG264 requires an external 24 VDC power supply to power the analog-to-digital conversion circuitry. This power is connected via the terminal base. If the \"User Power\" LED is not illuminated, the module will report zero or under-range values to the CPU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 15-channel \"Common Return\" affect wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike 8-channel isolated modules, all 15 channels on the IC200ALG264 share a single common return path. This means all field transmitters must be compatible with a shared ground system. For loops requiring full galvanic isolation between channels, a different module or external signal isolators should be used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a 4-20 mA wire is broken?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn 4-20 mA mode, the module provides a low-range diagnostic. If the current drops below approximately 3.5 mA, the PLC will typically report a \"Low Alarm\" or \"Open Wire\" fault for that specific channel, allowing for immediate maintenance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis high-density module must be paired with a compatible terminal base, such as the IC200TBT002 (Barrier style) or IC200TBP002 (Spring style). Ensure the base is keyed correctly to prevent accidental insertion of digital modules into the analog slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding for High-Density I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith 15 analog signals in close proximity, crosstalk and EMI are potential risks. Use high-quality shielded twisted-pair cabling and ensure the shields are terminated at the PLC end to a dedicated earth ground bar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Power Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the field transmitters are \"2-wire\" types (loop-powered), ensure your external 24 VDC power supply has sufficient amperage to power all 15 loops simultaneously, plus the module's own power requirement (approx. 50 mA).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695419486571,"sku":"IC200ALG264","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg264-analog-current-input-module-mxzzudnxg31_e1607b26-0523-4ea4-b508-394be5b33c7b.jpg?v=1766135354"},{"product_id":"ge-fanuc-versamax-ic200alg320-analog-output-module","title":"GE Fanuc VersaMax IC200ALG320 Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-128\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eIC200ALG320 (IC200-ALG-320)\u003c\/strong\u003e\u003cspan class=\"citation-128 citation-end-128\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, 4-channel analog output module from the GE VersaMax family.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed to provide unipolar voltage signals ranging from 0 to +10 VDC to control proportional valves, variable speed drives, and other actuators in industrial automation systems. Known for its compact footprint and ease of integration, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG320\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverts digital data from the CPU or Network Interface Unit (NIU) into stable, low-noise analog signals. Its modular design allows for \"Hot-Swapping\" and easy DIN-rail mounting, making it a reliable choice for decentralized control in HVAC, water treatment, and light manufacturing applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module features a 12-bit resolution, ensuring granular control over the output signal. Each of the four channels is independent, although they share a common ground. The VersaMax architecture separates the module electronics from the field wiring via a terminal base (sold separately), which allows for permanent wiring and simplified maintenance.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-127 citation-end-127\"\u003eThe module includes internal diagnostics to monitor the health of the D\/A converters and provides LED status indicators for \"OK\" and \"User Power\" to facilitate rapid on-site troubleshooting.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG320\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage (Unipolar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit (0 to 4095 counts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5% of full scale (at 25 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 4 ms for all 4 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 6.68 x 2.63 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200ALG320 requires an external +24 VDC power supply to drive the analog output circuits. This power is usually supplied through the terminal base. If the \"User Power\" LED is off, the analog outputs will not function even if the PLC is in Run mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Default\" behavior if the PLC stops communicating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring configuration in Proficy Machine Edition, you can set the \"Hold Last State\" or \"Output Default\" behavior. This ensures that if communication is lost, the 0-10V signal either stays at its current value or drops to a safe predefined voltage (usually 0V).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for 4-20mA current loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200ALG320 is a voltage-only module (0-10V). For current loop applications, you would need the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG321\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(which is the 0-20mA\/4-20mA equivalent).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Shielding:\u003c\/strong\u003e\u003cspan class=\"citation-126 citation-end-126\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalog signals are highly susceptible to electromagnetic interference (EMI).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAlways use shielded twisted-pair (STP) cabling. The shield should be grounded at the PLC end (the terminal base) and left floating at the actuator end to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module is compatible with several terminal bases, such as the IC200TBT001 (Barrier style) or IC200TBP001 (Spring style). Ensure the base is correctly keyed to the \"Analog Output\" position to prevent the insertion of a different module type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the input impedance of the receiving device (e.g., a VFD) is at least 2 kOhms. Connecting a load with too low an impedance will cause the voltage to drop and may trigger a thermal overload within the module's output stage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695420305771,"sku":"IC200ALG320","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg320-versamax-analog-output-module-pr3ohiktwjj_b726736e-011b-4782-8e11-16d6e7be3b4a.jpg?v=1766135387"},{"product_id":"ge-fanuc-versamax-ic200mdl740e-digital-output-module","title":"GE Fanuc VersaMax IC200MDL740E Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200MDL740E (IC200-MDL-740E) \u003c\/strong\u003eis a high-density, 16-point digital output module from the GE VersaMax I\/O family. Operating at 24 VDC, this module utilizes positive logic (Sourcing) transistor outputs, designed to drive various industrial loads such as solenoid valves, motor starters, and indicator lights. The \"E\" suffix signifies a specific hardware revision, often incorporating improved internal component heat dissipation or updated manufacturing standards. As a modular \"plug-and-play\" component, the IC200MDL740E is a staple in compact automation systems where space efficiency and reliable switching are paramount, offering seamless integration with VersaMax CPUs or Network Interface Units (NIUs) in distributed I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe VersaMax I\/O architecture allows for hot-insertion into a variety of terminal bases (sold separately). The IC200MDL740E features 16 independent output points divided into two groups of eight, providing flexibility in power distribution. Each output is equipped with short-circuit protection and thermal shutdown to prevent module damage during field-side faults.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-114 citation-end-114\"\u003eThe module provides LED status indicators for each point, mounted on the top of the carrier, enabling rapid visual diagnostics without the need for a programming terminal.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200MDL740E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Transistor (Sourcing\/Positive Logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Points (2 groups of 8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per point (Max 4 A per group)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 ms (Off to On \/ On to Off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 VAC continuous (between field\/logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 6.68 x 2.63 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between \"Positive Logic\" and \"Negative Logic\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-113 citation-end-113\"\u003eThe IC200MDL740E is a \"Sourcing\" (Positive Logic) module, meaning it switches the positive side of the 24 VDC supply to the load.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe load must then be connected to the common ground (OV). This is the most common standard in North American and European industrial control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different VersaMax modules on the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, VersaMax is a highly modular system. You can mix digital, analog, and specialty modules (like the IC200MDL740E) on the same expansion rack, provided the total power consumption does not exceed the capacity of the power supply module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. VersaMax modules are \"carriers\" that must be plugged into a base (such as the IC200TBT001 or IC200TBP001). This design allows for \"Permanent Wiring,\" where the module can be replaced without disturbing the field wires.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-112\"\u003e\u003c\/span\u003e\u003cstrong\u003eExternal Suppression:\u003c\/strong\u003e\u003cspan class=\"citation-112 citation-end-112\"\u003e\u003cspan\u003e \u003c\/span\u003eWhen driving inductive loads (e.g., solenoids or relay coils), it is highly recommended to install a suppression diode (flyback diode) across the load.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhile the module has internal protection, external suppression prevents electromagnetic noise from interfering with nearby analog signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent De-rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile each point can handle 0.5 A, be mindful of the \"Group Total.\" For the IC200MDL740E, the total current for each group of 8 points should not exceed 4 Amps. If your application requires all 16 points to be \"On\" simultaneously at high currents, ensure the enclosure has adequate ventilation to manage the heat generated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swapping Safety:\u003c\/strong\u003e\u003cspan class=\"citation-111 citation-end-111\"\u003e\u003cspan\u003e \u003c\/span\u003eVersaMax supports \"Hot-Swapping\" (inserting\/removing modules under power) if the terminal base is properly installed.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eHowever, always ensure the field-side 24 VDC power is disconnected or the load is in a safe state to prevent accidental machine movement during the swap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695421649259,"sku":"IC200MDL740E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic200mdl740e-output-modules-xch50inxgux_533d557a-d9e0-42bf-a7e4-104f6c06f3fe.jpg?v=1766135438"},{"product_id":"general-electric-ic200udr020-versamax-micro-controller-processor","title":"General Electric IC200UDR020 VersaMax Micro Controller Processor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200UDR020 is a compact, high-performance VersaMax Micro Controller Processor designed to provide scalable and efficient automation control for small to medium-sized industrial applications. Featuring 20 built-in discrete points, including 12 DC inputs and 8 relay outputs, this controller delivers reliable processing capabilities combined with a 24VDC power supply requirement. It is engineered to meet the demands of modern manufacturing environments requiring precise execution and rapid cycle times.\u003c\/p\u003e\n\u003cp\u003eAs part of the versatile VersaMax Micro platform, the IC200UDR020 supports system scalability through up to four expansion modules, allowing your control architecture to grow alongside your application needs. It features 32K words of data storage, 24K words of logic memory, and built-in high-speed counting and pulse train capabilities to manage motion and timing tasks effectively. Programming and configuration are streamlined using PAC Machine Edition software, supporting both ladder diagram and instruction list development environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e20 built-in discrete I\/O points consisting of 12 DC inputs and 8 relay outputs\u003c\/li\u003e\n  \u003cli\u003ePowered by an external 24VDC power supply\u003c\/li\u003e\n  \u003cli\u003eSupports up to 4 expansion units for flexible I\/O scaling\u003c\/li\u003e\n  \u003cli\u003eGenerous memory capacity with 24K words of logic memory and 32K words of data storage\u003c\/li\u003e\n  \u003cli\u003eBuilt-in RS-232 port with support for a secondary option port (RS-232, RS-485, USB, or Ethernet)\u003c\/li\u003e\n  \u003cli\u003eAdvanced motion control support including high-speed counters, pulse\/PWM outputs, and home\/jog commands\u003c\/li\u003e\n  \u003cli\u003eCompatible with PAC Machine Edition software for intuitive programming and diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete manufacturing and assembly automation\u003c\/li\u003e\n  \u003cli\u003eOEM machine building and compact packaging systems\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling control\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and environmental control systems\u003c\/li\u003e\n  \u003cli\u003eSmall-scale process control requiring PID and floating-point math\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eIC200UDR020\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eVersaMax Micro Controller Processor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBuilt-in Discrete I\/O\u003c\/td\u003e\n      \u003ctd\u003e20 Points (12 DC Inputs \/ 8 Relay Outputs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003e24VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLogic Memory\u003c\/td\u003e\n      \u003ctd\u003e24K Words\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Storage\u003c\/td\u003e\n      \u003ctd\u003e32K Words\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eScan Time\u003c\/td\u003e\n      \u003ctd\u003e1.1 ms \/ K\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Ports\u003c\/td\u003e\n      \u003ctd\u003e1 x RS-232, 1 x Second Option Port (RS-232, RS-485, USB, or Ethernet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHigh-Speed Counter\u003c\/td\u003e\n      \u003ctd\u003eUp to 4 channels at 100 kHz (32-bit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePulse Train \/ PWM\u003c\/td\u003e\n      \u003ctd\u003eUp to 4 channels at 65 kHz (32-bit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe IC200UDR020 features a fixed terminal arrangement for power, discrete inputs, and relay outputs. It includes a primary RS-232 serial communication port utilized for SNP slave, Modbus RTU, or serial I\/O protocols. Additionally, a secondary option port slot accepts plug-in communication modules including RS-232, RS-485, USB, or Ethernet interfaces to integrate seamlessly into plant networks and supervisory systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770153722219,"sku":"IC200UDR020","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IC200UDR001_1200x1200_2ef8c9f8-3e72-46c3-9fcc-111a03dd14dc.jpg?v=1787736899"},{"product_id":"general-electric-ic200bem104-versamax-asi-network-master-module","title":"General Electric IC200BEM104 VersaMax ASI Network Master Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric \u003cstrong\u003eIC200BEM104\u003c\/strong\u003e is a VersaMax Actuator-Sensor Interface (ASI) Network Master Module designed to integrate seamlessly into the VersaMax modular control system. This specialized communication module functions as an AS-Interface master, providing efficient, cost-effective data exchange between the programmable controller and lower-level binary actuators and sensors in industrial automation architectures.\u003c\/p\u003e\n\u003cp\u003eEngineered to support industrial networking standards, the IC200BEM104 simplifies system wiring by multiplexing power and data over a single unshielded two-conductor cable. It streamlines machine-level communication, reduces installation time, and enhances diagnostic capabilities across discrete automation tasks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConforms to the AS-Interface Specification for standard master protocol operations\u003c\/li\u003e\n\u003cli\u003eSupports communication with up to 31 slave devices on a single AS-Interface network loop\u003c\/li\u003e\n\u003cli\u003eExchanges up to 4 bits of input data and 4 bits of output data per individual slave address\u003c\/li\u003e\n\u003cli\u003eIntegrates directly into the VersaMax rack system without requiring complex custom backplane configuration\u003c\/li\u003e\n\u003cli\u003eProvides status LEDs for clear indication of module health, network status, and power conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDiscrete manufacturing and assembly lines\u003c\/li\u003e\n\u003cli\u003eConveyor and material handling systems\u003c\/li\u003e\n\u003cli\u003ePackaging and labeling machinery\u003c\/li\u003e\n\u003cli\u003eDecentralized machine safety and sensor monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number \/ SKU\u003c\/td\u003e\n\u003ctd\u003eIC200BEM104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eASI Network Master Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Slave Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 31 AS-Interface slaves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Exchange Capacity\u003c\/td\u003e\n\u003ctd\u003e4 bits input \/ 4 bits output per slave address\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe module features front-facing terminal connections designed for direct termination of the AS-Interface two-wire bus cable, alongside internal backplane interfaces that connect directly to the VersaMax CPU and power supply carrier bases. Integrated diagnostic LEDs give operators immediate feedback regarding network traffic, power supply status, and slave communication errors.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe IC200BEM104 mounts directly onto a standard VersaMax carrier base alongside other rack modules. Ensure that system power is disconnected before installing or removing the module. Connect the AS-Interface network cable to the designated terminals, observing correct polarity and shielding practices as outlined in the hardware manual to maintain signal integrity in electrically noisy environments.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770183639403,"sku":"IC200BEM104","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IC200BEM104_001_1200x1200_54687743-fd00-44be-b7a2-936236a5b3cd.png?v=1787882890"},{"product_id":"general-electric-ic200ual005-versamax-micro-controller-processor","title":"General Electric IC200UAL005 VersaMax Micro Controller Processor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200UAL005 is a scalable VersaMax Micro Controller Processor designed to deliver precise and reliable automation control for industrial applications. Part of the VersaMax Micro series, this controller offers a compact footprint while maintaining high processing performance, fast scan times, and flexible expansion options to match specific system requirements.\u003c\/p\u003e\n\u003cp\u003eThis 23-point PLC configuration includes integrated discrete inputs and outputs along with a built-in 24VDC power supply. Engineered for seamless integration, the controller supports PAC Machine Edition software for intuitive programming using Relay Ladder Diagram and Instruction List languages, ensuring straightforward setup, monitoring, and maintenance.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cdiv\u003e\u003cli\u003e23-point PLC featuring 13 discrete 24VDC inputs, 1 24VDC output, and 9 relay outputs\u003c\/li\u003e\u003c\/div\u003e\n  \u003cdiv\u003e\u003cli\u003eIntegrated 24VDC power supply for standalone operation\u003c\/li\u003e\u003c\/div\u003e\n  \u003cdiv\u003e\u003cli\u003eSupports up to four expansion modules to scale I\/O capacity\u003c\/li\u003e\u003c\/div\u003e\n  \u003cdiv\u003e\u003cli\u003eBuilt-in RS-232 serial port for SNP slave, Modbus RTU, and serial I\/O communication\u003c\/li\u003e\u003c\/div\u003e\n  \u003cdiv\u003e\u003cli\u003eBattery-backed RAM alongside a supercapacitor for reliable data retention and Real-Time Clock functionality\u003c\/li\u003e\u003c\/div\u003e\n  \u003cdiv\u003e\u003cli\u003eCompatible with PAC Machine Edition for streamlined configuration and troubleshooting\u003c\/li\u003e\u003c\/div\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cdiv\u003e\u003cli\u003eDiscrete manufacturing and machinery automation\u003c\/li\u003e\u003c\/div\u003e\n  \u003cdiv\u003e\u003cli\u003eOEM machine building requiring compact and scalable control\u003c\/li\u003e\u003c\/div\u003e\n  \u003cdiv\u003e\u003cli\u003eMaterial handling and conveyor systems\u003c\/li\u003e\u003c\/div\u003e\n  \u003cdiv\u003e\u003cli\u003eBuilding automation and environmental control panels\u003c\/li\u003e\u003c\/div\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eVersaMax Micro\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ SKU\u003c\/td\u003e\n      \u003ctd\u003eIC200UAL005\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal I\/O Points\u003c\/td\u003e\n      \u003ctd\u003e23 Points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n      \u003ctd\u003e13 Points (24VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n      \u003ctd\u003e1 Point (24VDC), 9 Points (Relay)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003eBuilt-in 24VDC Power Supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLogic Memory\u003c\/td\u003e\n      \u003ctd\u003e9K Words\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Storage\u003c\/td\u003e\n      \u003ctd\u003e2K Words\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eScan Time\u003c\/td\u003e\n      \u003ctd\u003e1.1 ms \/ K\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Ports\u003c\/td\u003e\n      \u003ctd\u003e1 x RS-232\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExpansion Support\u003c\/td\u003e\n      \u003ctd\u003eUp to 4 I\/O Expansion Modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe controller is equipped with removable terminal blocks for secure field wiring of discrete inputs and outputs. Communication is handled via the integrated RS-232 port, which supports SNP slave and Modbus RTU protocols for connection to programming devices, operator interfaces, or supervisory systems.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the controller securely on a standard DIN rail or via panel-mount screw holes within a suitable industrial enclosure. Ensure adequate clearance around the unit for ventilation and wiring access. Verify all power supply and ground connections before applying 24VDC power to prevent equipment damage.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770184261995,"sku":"IC200UAL005","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ic200ual005_1200x1200_6478a1ba-3eb6-4cf1-b375-7ea411653ff0.jpg?v=1787737814"},{"product_id":"general-electric-ic200mdl740-versamax-positive-logic-discrete-output-module","title":"General Electric IC200MDL740 VersaMax Positive Logic Discrete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200MDL740 is a high-performance VersaMax discrete output module designed to provide reliable switching in industrial automation environments. Featuring one group of 16 positive (sourcing) logic output points, this module efficiently switches loads to the positive side of the DC power supply, supplying necessary current to connected actuators, indicators, and control devices. It is an essential component for distributed control architectures utilizing the VersaMax I\/O platform.\u003c\/p\u003e\n\u003cp\u003eIntelligent processing and communication for the IC200MDL740 are managed externally by the system CPU or Network Interface Unit (NIU). The unit features integrated diagnostic LEDs for rapid visual status verification, including individual point on\/off status indicators, a field power indicator, and a backplane power indicator. Operating reliably across a nominal 12VDC to 24VDC range, this module supports flexible application requirements in modern manufacturing and process control systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 discrete output points arranged in a single isolated group\u003c\/li\u003e\n  \u003cli\u003ePositive (sourcing) logic design switching loads to the positive DC rail\u003c\/li\u003e\n  \u003cli\u003eSupport for 12VDC and 24VDC nominal external power supplies (12V output functionality requires module version -B or higher)\u003c\/li\u003e\n  \u003cli\u003eIndividual green LED indicators for each output point state\u003c\/li\u003e\n  \u003cli\u003eDedicated FLD PWR LED for field power status and OK LED for backplane power monitoring\u003c\/li\u003e\n  \u003cli\u003eCompact DIN-rail mountable VersaMax modular form factor\u003c\/li\u003e\n  \u003cli\u003eLow backplane current consumption of 45mA maximum at 5V output\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete manufacturing assembly lines\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling systems\u003c\/li\u003e\n  \u003cli\u003ePackaging and labeling machinery\u003c\/li\u003e\n  \u003cli\u003ePLC-based industrial process automation\u003c\/li\u003e\n  \u003cli\u003eMachine tool control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eIC200MDL740\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Platform\u003c\/td\u003e\n      \u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eDiscrete Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutputs per Module\u003c\/td\u003e\n      \u003ctd\u003e16 points (1 group of 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Logic Type\u003c\/td\u003e\n      \u003ctd\u003ePositive (Sourcing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n      \u003ctd\u003e+10.2 to +30VDC (+12\/24VDC nominal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Current Rating\u003c\/td\u003e\n      \u003ctd\u003e0.5A maximum per point at 30VDC (resistive); 2.0A max for 100ms inrush\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Drop\u003c\/td\u003e\n      \u003ctd\u003e0.3V maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Leakage Current\u003c\/td\u003e\n      \u003ctd\u003e0.5mA maximum at 30VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResponse Time\u003c\/td\u003e\n      \u003ctd\u003e0.2ms maximum (on); 1.0ms maximum (off)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n      \u003ctd\u003e45mA maximum at 5VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation\u003c\/td\u003e\n      \u003ctd\u003eUser input to logic (optical) and frame ground: 250VAC continuous; 1500VAC for 1 minute\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule ID Code\u003c\/td\u003e\n      \u003ctd\u003eFFFF8080\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eField Wiring Terminals: Removable plug-in terminal blocks supporting field connections for outputs A1 through A16 and power terminals (DC+ and DC-)\u003c\/li\u003e\n  \u003cli\u003eBus Connection: Connects directly to the VersaMax backplane carrier via standard bus interface\u003c\/li\u003e\n  \u003cli\u003eShorting Bar Support: B terminals can be linked using a shorting bar for additional bussed terminal capacity (up to 2A per point capacity)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure all external power sources are completely disconnected before installing, removing, or wiring the module.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely onto a standard DIN rail using the integrated VersaMax carrier mechanism, ensuring proper alignment with adjacent backplane modules.\u003c\/li\u003e\n  \u003cli\u003eWhen connecting inductive loads, use recommended external suppression circuits (such as flyback diodes or RC snubbers) across the load terminals to prevent electrical noise and contact wear.\u003c\/li\u003e\n  \u003cli\u003eObserve thermal derating guidelines and ambient temperature limits (up to 60 degC depending on mounting orientation and simultaneous active points) as outlined in the system documentation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770189439339,"sku":"IC200MDL740","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ic200mdl740_1200x1200_673d8b51-1ade-4a86-a0ec-522bd1215a3f.jpg?v=1787738023"},{"product_id":"general-electric-ic200mdl330-versamax-discrete-isolated-output-module","title":"General Electric IC200MDL330 VersaMax Discrete Isolated Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200MDL330 is a 16-point discrete isolated output module designed for use within the VersaMax I\/O system family. This high-density output module provides reliable switching capabilities for industrial automation applications, requiring an external 120VAC power supply to energize connected loads. Intelligent processing and communication functions are handled directly by the system CPU or Network Interface Unit (NIU).\u003c\/p\u003e\n\u003cp\u003eEngineered for safety and operational reliability, the IC200MDL330 features robust optical isolation between field outputs and internal logic, as well as group-to-group and point-to-point isolation barriers. Built-in LED indicators provide clear visual feedback, displaying individual point ON\/OFF states alongside a dedicated backplane power status indicator.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 isolated discrete output channels\u003c\/li\u003e\n  \u003cli\u003eExternal power supply rating of 85 to 132VAC (47 to 63Hz) at 120VAC nominal\u003c\/li\u003e\n  \u003cli\u003eRobust isolation: 250VAC continuous and 1500VAC for 1 minute (user input to logic, group-to-group, and point-to-point)\u003c\/li\u003e\n  \u003cli\u003eIndividual green logic-driven LED indicators for each output point\u003c\/li\u003e\n  \u003cli\u003eDedicated OK LED for backplane power status monitoring\u003c\/li\u003e\n  \u003cli\u003eBuilt-in snubber circuits and MOVs for output protection against transient overvoltages\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting compatibility within the VersaMax modular architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete actuator control (solenoids, contactors, and indicator lamps)\u003c\/li\u003e\n  \u003cli\u003eAC motor starter interfacing\u003c\/li\u003e\n  \u003cli\u003eIndustrial manufacturing assembly lines\u003c\/li\u003e\n  \u003cli\u003eProcess control and packaging machinery\u003c\/li\u003e\n  \u003cli\u003eDistributed I\/O drops in hazardous location environments (Class I, Division 2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eIC200MDL330\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e16 isolated outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e85 to 132 VAC (47 to 63Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Current per Point\u003c\/td\u003e\n      \u003ctd\u003e10mA minimum to 0.5A maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInrush Current\u003c\/td\u003e\n      \u003ctd\u003e5.0A maximum for one cycle (20ms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Drop\u003c\/td\u003e\n      \u003ctd\u003e2.0V maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Leakage Current\u003c\/td\u003e\n      \u003ctd\u003eLess than 2mA at 132VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResponse Time\u003c\/td\u003e\n      \u003ctd\u003eLess than 1\/2 cycle maximum (on and off)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n      \u003ctd\u003e140mA maximum (5V output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation Rating\u003c\/td\u003e\n      \u003ctd\u003e250VAC continuous; 1500VAC for 1 min (optical logic, group-to-group, point-to-point)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule ID Code\u003c\/td\u003e\n      \u003ctd\u003e88408840\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eField wiring terminals accommodate two-row or three-row terminal carriers\u003c\/li\u003e\n  \u003cli\u003eTerminals A1 through A16 handle Outputs 1 through 8 and their respective returns\u003c\/li\u003e\n  \u003cli\u003eTerminals B1 through B16 handle Outputs 9 through 16 and their respective returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure all external power is disconnected before installing, wiring, or replacing modules in hazardous or non-hazardous locations.\u003c\/li\u003e\n  \u003cli\u003eWhen connecting output channels to inductive loads, use external suppression circuits (such as MOV or RC networks) to prolong relay and switch contact life.\u003c\/li\u003e\n  \u003cli\u003eObserve thermal derating guidelines regarding ambient temperature and the number of points active simultaneously to prevent module overheating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770194059627,"sku":"IC200MDL330","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ic200mdl330_1200x1200_4992d2c5-b388-417c-9ebc-afd90552fc16.jpg?v=1787738195"},{"product_id":"general-electric-ic200uex009-versamax-micro-expansion-processor","title":"General Electric IC200UEX009 VersaMax Micro Expansion Processor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200UEX009 is a 14-point expansion module belonging to the VersaMax Micro scalable PLC product family. Engineered to extend the I\/O capacity and functional flexibility of compatible General Electric micro control systems, this unit provides precise and dependable automation performance for compact industrial machinery and distributed control architectures.\u003c\/p\u003e\n\u003cp\u003eFeaturing integrated discrete input and output channels, the IC200UEX009 integrates seamlessly with base controllers using standard expansion architecture. Its robust hardware design ensures reliable operation in demanding industrial environments where space efficiency, quick response times, and dependable signal processing are critical to maintaining optimal productivity.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul style=\"margin:0.4em 0;padding-left:1.25em;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-Point Expansion Capacity:\u003c\/strong\u003e Integrates eight (8) 120VAC discrete inputs and six (6) relay outputs to expand controller monitoring and control points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable System Architecture:\u003c\/strong\u003e Supports expansion limits up to four expansion modules per base controller for adaptable machine design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Relay Switching:\u003c\/strong\u003e Equipped with normally-open relay outputs capable of driving various industrial loads such as motor starters, actuators, and indicator lights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Compatibility:\u003c\/strong\u003e Designed for standard 120VAC control signals commonly utilized in industrial automation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePAC Machine Edition Support:\u003c\/strong\u003e Programmed and configured intuitively through Emerson \/ General Electric PAC Machine Edition software suites.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOEM machinery and discrete manufacturing equipment\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and material handling lines\u003c\/li\u003e\n  \u003cli\u003ePackaging, labeling, and sorting machines\u003c\/li\u003e\n  \u003cli\u003eSmall-scale HVAC and building automation control panels\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment package skids\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric (GE Fanuc \/ Emerson)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eIC200UEX009\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eVersaMax Micro Expansion Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n      \u003ctd\u003e8 points, 120VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n      \u003ctd\u003e6 points, Relay Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExpansion Group\u003c\/td\u003e\n      \u003ctd\u003eMicro 14 Expansion\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the IC200UEX009 expansion module securely onto a standard DIN rail or panel surface in accordance with General Electric hardware manuals. Ensure proper spacing around the unit to allow adequate natural convection cooling. Connect the 120VAC field input devices to the designated input terminals and wire separate external power supplies to the relay output circuits as required by application loads. Maintain correct grounding practices and verify all terminal connections before applying system power.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770194321771,"sku":"IC200UEX009","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IC200UDR001_1200x1200_d9f849a0-2f89-43a1-a72b-785f27f0bc17.jpg?v=1787738209"},{"product_id":"general-electric-ic200uar028-versamax-micro-28-point-plc-controller","title":"General Electric IC200UAR028 VersaMax Micro 28-Point PLC Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200UAR028 is a 28-point micro programmable logic controller from the VersaMax Micro platform, engineered for standalone industrial machinery, utility skid automation, and distributed control tasks. Powered by a 120\/240 VAC line supply, this compact all-in-one controller integrates discrete AC inputs, relay outputs, CPU logic execution, and serial communications within a single DIN-rail or panel-mounted unit.\u003c\/p\u003e\n\u003cp\u003eThe unit features 16 reactive 120 VAC discrete inputs and 12 Form A relay outputs divided across two current capacities: two 10 A relay circuits designed to switch heavier inductive or resistive field loads, and ten 2 A relay circuits intended for general pilot devices, motor starters, and visual indicators. The controller provides 9 K words of user program logic memory and 2 K words of register data space for standard ladder and logic execution.\u003c\/p\u003e\n\u003cp\u003eOnboard communications comprise two physical serial channels: Port 1 provides an RS-232 connection through an RJ-45 jack, while Port 2 offers an RS-485 interface via a 15-pin D-sub connector. For applications requiring capacity beyond the base 28 points, the IC200UAR028 interfaces with up to four VersaMax Micro expansion units, enabling expansion up to a maximum of 140 physical I\/O points.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e28 embedded I\/O points: 16 discrete AC inputs and 12 Form A relay outputs\u003c\/li\u003e\n  \u003cli\u003eSplit-capacity relay staging: two 10 A contacts and ten 2 A contacts\u003c\/li\u003e\n  \u003cli\u003eIntegrated power supply supporting 100 to 240 VAC nominal line power at 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eDual serial ports: Port 1 (RS-232 on RJ-45) and Port 2 (RS-485 on 15-pin D-sub)\u003c\/li\u003e\n  \u003cli\u003eExpansion bus supporting up to 4 VersaMax Micro discrete or analog expansion modules\u003c\/li\u003e\n  \u003cli\u003eIntegrated real-time clock and dual onboard potentiometers for manual analog setting\u003c\/li\u003e\n  \u003cli\u003eDirect installation onto standard 35 mm DIN rail or flat backpanel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Line\u003c\/td\u003e\n      \u003ctd\u003eVersaMax Micro\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003eIC200UAR028\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e100 to 240 VAC (120\/240 VAC nominal), 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Embedded I\/O\u003c\/td\u003e\n      \u003ctd\u003e28 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiscrete Input Points\u003c\/td\u003e\n      \u003ctd\u003e16 AC inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n      \u003ctd\u003e120 VAC nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Circuit Type\u003c\/td\u003e\n      \u003ctd\u003eReactive (resistor \/ capacitor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiscrete Output Points\u003c\/td\u003e\n      \u003ctd\u003e12 Relay outputs (Form A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Contact Current Rating\u003c\/td\u003e\n      \u003ctd\u003e2 outputs at 10 A, 10 outputs at 2 A (240 VAC \/ 24 VDC resistive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUser Logic Program Memory\u003c\/td\u003e\n      \u003ctd\u003e9 K words\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRegister Memory\u003c\/td\u003e\n      \u003ctd\u003e2 K words\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSerial Interface Port 1\u003c\/td\u003e\n      \u003ctd\u003eRS-232 (RJ-45), SNP \/ SNP-X protocol support\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSerial Interface Port 2\u003c\/td\u003e\n      \u003ctd\u003eRS-485 (15-pin D-sub), SNP \/ SNP-X \/ Modbus RTU protocol support\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExpansion Module Capacity\u003c\/td\u003e\n      \u003ctd\u003eUp to 4 expansion units\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum System Physical I\/O\u003c\/td\u003e\n      \u003ctd\u003e140 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnalog Adjustment Potentiometers\u003c\/td\u003e\n      \u003ctd\u003e2 built-in potentiometers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Retention Battery\u003c\/td\u003e\n      \u003ctd\u003eIC200ACC403 (sold separately)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Format\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail or panel mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e150 x 90 x 76 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.60 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConfiguration Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfigure and program the unit using VersaPro 1.1 or higher, or Proficy Machine Edition Logic Developer PLC.\u003c\/li\u003e\n  \u003cli\u003eTo protect user program data and preserve real-time clock values during system power cycles, install the IC200ACC403 lithium battery while input power is switched off.\u003c\/li\u003e\n  \u003cli\u003eConnect compatible VersaMax Micro discrete or analog expansion modules to the right-side expansion port to expand system capacity up to 140 physical I\/O points.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770195730795,"sku":"IC200UAR028","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ic200uex012_6_1200x1200_133e94b9-6f65-4cc1-93fa-9bccdd828c58.jpg?v=1787738266"},{"product_id":"general-electric-ic200erm002-non-isolated-expansion-receiver-module","title":"General Electric IC200ERM002 Non-Isolated Expansion Receiver Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200ERM002 is a Non-Isolated Expansion Receiver Module designed to interface an expansion rack to a PLC or Network Interface Unit (NIU) I\/O station within PACSystems and compatible distributed control architectures. This module serves as the primary communication and power distribution node for an expansion rack, capable of supporting up to eight standard discrete I\/O, analog, or special-purpose modules. Equipped with an onboard power supply, the unit provides the necessary 5VDC and 3.3VDC operating power directly to the modules slotted within the same rack, streamlining hardware footprints by eliminating external auxiliary power routing for rack-level logic.\u003c\/p\u003e\n\u003cp\u003eThe module features dual 26-pin female D-shell expansion ports configured for RS-485 differential or single-ended communication topologies. In multi-rack configurations utilizing an Expansion Transmitter Module (ETM001), the upper port accepts incoming data from the main rack or preceding expansion node, while the lower port facilitates daisy-chaining to subsequent racks or accepting a terminal termination plug. Alternatively, in single-rack local systems, the IC200ERM002 interfaces directly with the CPU or NIU serial port over distances up to 1 meter using dedicated cabling. Occupying slot 0 (the leftmost position) of the expansion backplane, the unit integrates rotary rack ID selection switches (1 through 7) and comprehensive diagnostic LED indicators for real-time monitoring of power status, communication links, and scan synchronization.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports connection of up to 8 I\/O and special-purpose modules per expansion rack\u003c\/li\u003e\n  \u003cli\u003eDual 26-pin female D-shell connectors for incoming data and daisy-chaining or termination\u003c\/li\u003e\n  \u003cli\u003eIntegrated power supply providing 5VDC (70mA max) and 3.3VDC (20mA) backplane outputs\u003c\/li\u003e\n  \u003cli\u003eRotary expansion rack ID switch (settings 1 through 7) located behind upper access door\u003c\/li\u003e\n  \u003cli\u003eComprehensive diagnostic LED array displaying PWR, EXP RX, and SCAN operational states\u003c\/li\u003e\n  \u003cli\u003eCompatible with RS-485 differential multi-rack architectures up to 15 meters total cable length\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed I\/O rack expansion for GE PACSystems PLC and NIU controller nodes\u003c\/li\u003e\n  \u003cli\u003eMulti-rack industrial automation networking requiring synchronized backplane data exchange\u003c\/li\u003e\n  \u003cli\u003eModular machine control systems demanding localized I\/O drop positioning\u003c\/li\u003e\n  \u003cli\u003eRetrofit and expansion of legacy GE-Fanuc control architectures up to seven remote racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number\u003c\/td\u003e\n      \u003ctd\u003eIC200ERM002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eNon-Isolated Expansion Receiver Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Capacity\u003c\/td\u003e\n      \u003ctd\u003eUp to 8 I\/O and special-purpose modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Current Consumption (5V Output)\u003c\/td\u003e\n      \u003ctd\u003e70 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Current Consumption (3.3V Output)\u003c\/td\u003e\n      \u003ctd\u003e20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Cable Length\u003c\/td\u003e\n      \u003ctd\u003e15 meters (differential), 1 meter (single-ended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEffective Data Rate\u003c\/td\u003e\n      \u003ctd\u003e5 Mbits\/sec (differential), 2.765 Mbits\/sec (single-ended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eNon-isolated differential or single-ended communications\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExpansion Connectors\u003c\/td\u003e\n      \u003ctd\u003eTwo 26-pin female D-shell expansion ports\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRack Position Requirement\u003c\/td\u003e\n      \u003ctd\u003eSlot 0 (leftmost position of the expansion rack)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRack ID Configuration\u003c\/td\u003e\n      \u003ctd\u003eRotary switch (IDs 1 through 7)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUpper D-Shell Port:\u003c\/strong\u003e Receives incoming expansion cable from the main rack transmitter or preceding expansion receiver.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLower D-Shell Port:\u003c\/strong\u003e Used for daisy-chaining to the next expansion rack or attaching the *ACC201 termination plug on the final rack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRack ID Switch:\u003c\/strong\u003e Rotary dial positioned beneath the upper-left access door for assigning rack addresses 1 through 7.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Status Indicators:\u003c\/strong\u003e Green PWR (5VDC presence), bi-color EXP RX (bus communication), and green\/amber SCAN (CPU scan state).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Compliant\u003c\/li\u003e\n  \u003cli\u003eUL \/ cUL-us Listed\u003c\/li\u003e\n  \u003cli\u003eDemko Hazardous Location Approval (Ex nV II T4)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770198647147,"sku":"IC200ERM002","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ic200erm002_1200x1200_31562ab8-50a0-4fb4-9885-5a3662ba8170.jpg?v=1787738381"},{"product_id":"general-electric-ic200mdl640-versamax-discrete-input-module","title":"General Electric IC200MDL640 VersaMax Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200MDL640 is a high-performance VersaMax discrete input module designed to interface 16 input points grouped into two isolated sets of eight channels within industrial automation architectures. Engineered for reliable signal acquisition, the module processes 24VDC nominal industrial field signals, supporting both positive and negative logic configurations to accommodate diverse sensor output types. It mounts directly onto a standard DIN rail carrier and communicates via the system backplane, receiving its operational power directly from the rack infrastructure.\u003c\/p\u003e\n\u003cp\u003eThis input module integrates optical isolation between field inputs and the logic plane, protecting internal controller components from transient voltage spikes and ground loops common in heavy industrial environments. Individual green LED indicators provide clear visual feedback for each point status, simplifying diagnostic procedures and loop troubleshooting during runtime operations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 discrete input channels configured in two isolated groups of 8 points\u003c\/li\u003e\n  \u003cli\u003eSupports 24VDC nominal input voltage with compatible positive and negative logic wiring\u003c\/li\u003e\n  \u003cli\u003eOptical isolation rated at 250VAC continuous and 1500VAC for 1 minute between user input and logic\u003c\/li\u003e\n  \u003cli\u003eConfigurable input filter times of 0ms, 1.0ms default, or 7.0ms to mitigate electrical noise and switch bounce\u003c\/li\u003e\n  \u003cli\u003eIndividual point LED status indicators for real-time ON\/OFF diagnostic monitoring\u003c\/li\u003e\n  \u003cli\u003eLow backplane current consumption drawing a maximum of 25mA from the 5V output\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete sensor signal acquisition from proximity switches, limit switches, and photoelectric cells\u003c\/li\u003e\n  \u003cli\u003eMachine safety and status monitoring in high-speed discrete manufacturing lines\u003c\/li\u003e\n  \u003cli\u003eProcess control status input integration for packaging, material handling, and assembly machinery\u003c\/li\u003e\n  \u003cli\u003eRemote rack I\/O signal collection in distributed industrial automation networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eVersaMax\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number\u003c\/td\u003e\n      \u003ctd\u003eIC200MDL640\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eDiscrete Input Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e16 points (2 groups of 8)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e24VDC nominal (0 to 30VDC range)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n      \u003ctd\u003e+15 to +30VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n      \u003ctd\u003e0 to +5VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOn-State Current\u003c\/td\u003e\n      \u003ctd\u003e2.0 to 5.5mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOff-State Current\u003c\/td\u003e\n      \u003ctd\u003e0 to 0.5mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Impedance\u003c\/td\u003e\n      \u003ctd\u003e10 kOhms maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResponse Time\u003c\/td\u003e\n      \u003ctd\u003e0.5ms maximum (plus selectable filter time)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n      \u003ctd\u003e25mA maximum at 5VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation\u003c\/td\u003e\n      \u003ctd\u003e250VAC continuous, 1500VAC for 1 min (optical input-to-logic and group-to-group)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThermal Derating\u003c\/td\u003e\n      \u003ctd\u003eNo derating required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Compliant\u003c\/li\u003e\n  \u003cli\u003eUL Listed \/ cUL-us\u003c\/li\u003e\n  \u003cli\u003eATEX Group 2 Category 3 Hazardous Location Approval\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770212475243,"sku":"IC200MDL640","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ic200mdl640_1200x1200_2abd636a-26c4-4e8b-a80a-2cbdd0669b25.jpg?v=1787738844"},{"product_id":"general-electric-ic200dtx650-versamax-dp-hmi-operator-interface","title":"General Electric IC200DTX650 VersaMax DP HMI Operator Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200DTX650 is a VersaMax DP Human-Machine Interface (HMI) operator terminal engineered to provide local monitoring, alarm handling, and operator control for industrial automation architectures. This compact interface connects seamlessly with VersaMax PLC systems and other PROFIBUS DP compatible control networks, offering real-time visualization of process parameters and machine states on the shop floor.\u003c\/p\u003e\n\u003cp\u003eFeaturing a clear 4-line by 16-character LCD backlit display paired with 8 user-configurable function keys, the IC200DTX650 facilitates direct operator intervention, setpoint adjustment, and diagnostic troubleshooting without requiring a dedicated engineering workstation. It supports up to 200 stored messages for comprehensive alarm management and system messaging. Built for panel-mount industrial environments, this operator interface simplifies system integration while delivering robust localized control capabilities.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4x16 character LCD display with integrated backlight for visibility in varying lighting conditions\u003c\/li\u003e\n  \u003cli\u003e8 user-programmable function keys for direct operational control and menu navigation\u003c\/li\u003e\n  \u003cli\u003eSupports up to 200 stored messages for structured alarm management and event logging\u003c\/li\u003e\n  \u003cli\u003ePROFIBUS DP communication interface for deterministic data exchange with PACSystems and VersaMax controllers\u003c\/li\u003e\n  \u003cli\u003eCompact panel-mount enclosure designed for space-constrained industrial control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLocal operator interface and alarm annunciation for VersaMax PLC nodes\u003c\/li\u003e\n  \u003cli\u003eMachine status visualization and parameter adjustment in discrete manufacturing cells\u003c\/li\u003e\n  \u003cli\u003eDiagnostic message display and error tracking for automated packaging machinery\u003c\/li\u003e\n  \u003cli\u003eOperator control terminal for material handling and conveyor systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eVersaMax\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number\u003c\/td\u003e\n      \u003ctd\u003eIC200DTX650\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDisplay Type\u003c\/td\u003e\n      \u003ctd\u003e4 x 16 Character LCD with Backlight\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFunction Keys\u003c\/td\u003e\n      \u003ctd\u003e8 Programmable Keys\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMessage Capacity\u003c\/td\u003e\n      \u003ctd\u003eUp to 200 Stored Messages\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003ePanel Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770213785963,"sku":"IC200DTX650","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IC200DTX650_1200x1200_19372b90-c5a7-4e05-8c33-0ba3c4549f63.jpg?v=1787738913"},{"product_id":"general-electric-ic200mdl329-versamax-discrete-isolated-output-module","title":"General Electric IC200MDL329 VersaMax Discrete Isolated Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200MDL329 is a VersaMax discrete isolated output module designed for industrial automation control systems. This compact module features 8 isolated discrete outputs, providing reliable switching capabilities for 120VAC field loads. Intelligent processing for the module is handled by the system CPU or Network Interface Unit (NIU), ensuring seamless integration within the VersaMax I\/O platform architecture.\u003c\/p\u003e\n\u003cp\u003eAn external 120VAC power supply is required to switch power to the connected loads. The unit incorporates optical isolation between user logic and internal circuitry, along with built-in snubber circuits and metal oxide varistors (MOVs) on each output for enhanced transient protection against inductive load switching.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cstrong\u003e8 Isolated Discrete Outputs:\u003c\/strong\u003e Dedicated output channels designed for 120VAC nominal operation.\n  \u003cstrong\u003eOptical Isolation:\u003c\/strong\u003e Provides robust electrical separation between user inputs, logic circuitry, and frame ground.\n  \u003cstrong\u003eDiagnostic LEDs:\u003c\/strong\u003e Individual green LEDs display the ON\/OFF state of each output point, while a dedicated OK LED indicates the presence of backplane power.\n  \u003cstrong\u003eBuilt-In Protection:\u003c\/strong\u003e Each output channel includes integrated snubbers and MOVs to suppress voltage spikes from inductive loads.\n  \u003cstrong\u003eCompact VersaMax Form Factor:\u003c\/strong\u003e Optimized for DIN-rail mounting and quick carrier installation within modular automation setups.\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete actuator control in manufacturing assembly lines\u003c\/li\u003e\n  \u003cli\u003eAC solenoid valve and relay interfacing\u003c\/li\u003e\n  \u003cli\u003ePackaging and material handling equipment\u003c\/li\u003e\n  \u003cli\u003eProcess control panel integration\u003c\/li\u003e\n  \u003cli\u003eHVAC equipment automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ SKU\u003c\/td\u003e\n      \u003ctd\u003eIC200MDL329\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Platform\u003c\/td\u003e\n      \u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e8 isolated outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule ID Code\u003c\/td\u003e\n      \u003ctd\u003eFFFF8840\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e85 to 132 VAC (47 to 63 Hz), 120 VAC nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Current\u003c\/td\u003e\n      \u003ctd\u003e10 mA minimum per point, 0.5 A maximum per point\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n      \u003ctd\u003e5.0 A for one cycle (20 ms maximum)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Drop\u003c\/td\u003e\n      \u003ctd\u003e2.0 V maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Leakage Current\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mA at 132 VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResponse Time\u003c\/td\u003e\n      \u003ctd\u003eLess than 0.5 cycle maximum (On and Off)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n      \u003ctd\u003e70 mA maximum (5V output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation Rating\u003c\/td\u003e\n      \u003ctd\u003e250 VAC continuous, 1500 VAC for 1 minute (user input to logic and frame ground)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Protection\u003c\/td\u003e\n      \u003ctd\u003eSnubber and MOVs on each output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe module mounts onto a standard VersaMax carrier with either two or three rows of terminals. For the IC200MDL329 8-point module, connections A1 through A16 handle output channels and their respective returns. B-row terminals can be utilized for additional bussed connections by installing an optional shorting bar with a maximum current-carrying capacity of 2A per point.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure all rack power and external load power supplies are turned off before installing or removing modules in hazardous or non-hazardous locations.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely onto its corresponding VersaMax carrier on a standard DIN rail.\u003c\/li\u003e\n  \u003cli\u003eWhen connecting to inductive loads, the use of external suppression circuits is strongly recommended in addition to internal module protection.\u003c\/li\u003e\n  \u003cli\u003eObserve proper thermal derating guidelines based on ambient operating temperatures and simultaneous active output points.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770261496171,"sku":"IC200MDL329","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ic200mdl329_1200x1200_026c62e6-9429-4edf-8456-00edce1227b8.jpg?v=1787739762"}],"url":"https:\/\/www.plcprotech.com\/collections\/ge-versamax.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}