{"title":"Honeywell ControlEdge HC900 \/ PLC","description":"\u003cp\u003eThe Honeywell ControlEdge HC900 is a modular, high-availability PLC and process controller that bridges the gap between discrete and process automation. Its architecture features a rack-based design with redundant CPUs, power supplies, and a wide array of high-density analog and digital I\/O modules. Technical characteristics include an easy-to-use function block configuration environment, non-interfering safety and control on the same platform (SIL2), and extensive networking options. Functionally, the HC900 is optimized for thermal control, water treatment, and packaging machinery, providing sophisticated PID control and data logging. Its versatility allows it to function as a standalone unit or integrate seamlessly into \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/honeywell-experion-pks-c300-series-c\"\u003eExperion PKS\u003c\/a\u003e for plant-wide visualization.\u003c\/p\u003e","products":[{"product_id":"honeywell-900b16-0001-controledge-hc900-16-slot-i-o-chassis","title":"Honeywell 900B16-0001 ControlEdge HC900 16-Slot I\/O Chassis","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001 (900B16-0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity 16-slot I\/O rack designed for the Honeywell ControlEdge HC900 Process \u0026amp; Safety Controller system. This chassis serves as the physical and communication backbone for various HC900 I\/O modules, including analog inputs\/outputs and digital inputs\/outputs. Engineered for modularity and scalability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both standard process control and SIL 2 safety-related applications, providing a ruggedized mounting platform with integrated power distribution and backplane communications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlEdge HC900 \/ Series 900\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Slots (for I\/O modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReserved Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated slots for Power Supply and Scanner\/CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistributed 5V and 24V from Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Mount (Internal Cabinet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 2 Certified (when used with appropriate modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade aluminum\/steel hybrid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed internal bus for I\/O scanning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eStructural Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to maximize I\/O density within a single rack footprint. It facilitates the \"hot-swap\" capability of the HC900 system, allowing modules to be replaced while the rest of the rack remains powered and operational. The chassis includes integrated grounding points and terminal block connectors for the power supply, ensuring clean power delivery to sensitive analog instrumentation. It is a critical component for large-scale boiler control, thermal processing, and water treatment applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this chassis include the Power Supply or CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the empty 16-slot rack frame. The Power Supply (e.g., 900P01) and the CPU or Scanner module must be purchased and installed separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix safety and non-safety modules in this rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the HC900 architecture allows for the coexistence of non-safety and safety-critical I\/O within the same chassis, provided the system configuration adheres to the Honeywell Safety Manual guidelines.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667990147435,"sku":"900B16-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-900b16-0001-plc-module-s1z4in1e0wu_03d48335-7db6-4543-a6e4-e6c67c76b1f5.jpg?v=1765504887"},{"product_id":"honeywell-900rr0-0200-redundant-controller-rack","title":"Honeywell 900RR0-0200 Redundant Controller Rack","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900RR0-0200\u003c\/strong\u003e is a specialized \u003cstrong\u003eRedundant Controller Rack\u003c\/strong\u003e assembly designed for the 900 platform, providing the structural and electrical foundation for redundant Control Processor Module (CPM) operations. This rack is engineered to house dual CPMs, ensuring high-availability control and seamless failover capabilities in mission-critical process automation environments. By providing a stable, integrated backplane for redundant architectures, the \u003cstrong\u003e900RR0-0200\u003c\/strong\u003e maximizes system uptime and fault tolerance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Engineered specifically to host redundant CPM configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Assembly:\u003c\/strong\u003e Factory-integrated rack assembly for simplified system commissioning\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Form Factor:\u003c\/strong\u003e Compact 10.3-inch width designed to fit standard control cabinet profiles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Purpose-built for the Honeywell 900 platform to ensure reliable backplane communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-availability Distributed Control Systems (DCS)\u003c\/li\u003e\n\u003cli\u003eProcess safety and critical logic control applications\u003c\/li\u003e\n\u003cli\u003eLarge-scale industrial manufacturing requiring zero-downtime automation\u003c\/li\u003e\n\u003cli\u003eBatch processing and furnace control where redundancy is a operational requirement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900RR0-0200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRedundant Controller Rack (Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e900 Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137mm H x 261.6mm W x 151.7mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.751 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the rack horizontally within the enclosure using all provided mounting points to ensure vibration resistance and long-term mechanical stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Setup:\u003c\/strong\u003e Install the primary and secondary CPMs into the designated redundant slots; ensure both modules are fully seated to engage the backplane pins correctly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Maintain a minimum clearance around the rack assembly to facilitate proper airflow, as redundant controller configurations generate localized thermal loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the rack chassis to the main system common ground to ensure optimal electromagnetic compatibility (EMC) and protection against transient interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Utilize dedicated cable management to keep communication and power wiring organized, preventing physical stress on the backplane connectors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705608171883,"sku":"900RR0-0200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900rr0-0200-3cfjfdphwjh_4897681b-ce0a-460e-809c-6fb200ab8766.jpg?v=1766651562"},{"product_id":"honeywell-900p01-0301-120-240vac-power-supply","title":"Honeywell 900P01-0301 120\/240VAC Power Supply","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900P01-0301\u003c\/strong\u003e is a high-reliability \u003cstrong\u003e120\/240VAC Power Supply\u003c\/strong\u003e designed to provide stable, regulated power to the ControlEdge HC900 controller system. This module is engineered to handle a wide range of input voltages, making it adaptable to diverse industrial power grids. With an output rating of 58 W and integrated test jacks for easy monitoring of 5 Vdc and 24 Vdc rails, this power supply ensures consistent performance for sensitive control logic and field instrumentation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Input:\u003c\/strong\u003e Wide operating range of 90 to 264 V AC (47–63 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency:\u003c\/strong\u003e Delivers a 58 W output capacity from a 130 VA input rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Monitoring:\u003c\/strong\u003e Integrated test jacks for real-time verification of 5 Vdc and 24 Vdc output levels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Transient Handling:\u003c\/strong\u003e Designed for a 40 A peak-to-peak inrush current to ensure stability during power-up\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHold-up Capability:\u003c\/strong\u003e Provides 20 ms of hold-up time at 115 V AC to maintain system integrity during brief power interruptions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary power distribution for ControlEdge HC900 rack systems\u003c\/li\u003e\n\u003cli\u003eIndustrial automation cabinet power supply\u003c\/li\u003e\n\u003cli\u003eProcess control loop power source for PLC and DCS architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900P01-0301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e120\/240VAC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e90 to 264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003e58 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e40 A peak-to-peak (120 ms @ 240 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-up Time\u003c\/td\u003e\n\u003ctd\u003e20 ms @ 115 V AC (max load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Terminal\u003c\/td\u003e\n\u003ctd\u003eScrew type (0.3 mm2 to 3.3 mm2 \/ #12-22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137mm H x 72.6mm W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriately sized cabling (#12-22 AWG) for the screw-type terminals; ensure all connections are tight to prevent resistive heating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Mount the power supply vertically to allow for natural convection cooling, maintaining the specified operational temperature range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e The unit contains an internal non-replaceable fuse; ensure the input circuit is protected by an external appropriately rated circuit breaker to prevent damage during upstream faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Use the front-panel test jacks to periodically verify that the 5 Vdc and 24 Vdc outputs are within tolerance during preventative maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705608991083,"sku":"900P01-0301","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900p01-0301-u325hnrtmk0_500d3051-1b17-4f5b-a857-b79e0d1fe39d.jpg?v=1766651585"},{"product_id":"honeywell-900h01-0202-digital-output-relay-module","title":"Honeywell 900H01-0202 Digital Output Relay Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900H01-0202\u003c\/strong\u003e is an 8-channel \u003cstrong\u003eDigital Output Relay Module\u003c\/strong\u003e designed for the ControlEdge HC900 system, providing robust switching capabilities for industrial loads. This module features a combination of 4 Form A and 4 Form C electromechanical relays, offering versatile control for both AC and DC field devices. The module is engineered with comprehensive galvanic isolation between output contacts and the logic circuitry, ensuring system safety and noise immunity in high-load industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Versatility:\u003c\/strong\u003e Equipped with 4 Form A (Normally Open) and 4 Form C (SPDT) relays\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Switching:\u003c\/strong\u003e Supports up to 4 A at 240 Vac or 30 Vdc (resistive load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Enhanced protection between output contacts and internal logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Operational Life:\u003c\/strong\u003e Rated for 5 x 10^7 mechanical operations, ensuring durability for frequent cycling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Load Handling:\u003c\/strong\u003e Capable of driving both resistive loads and incandescent lamp loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect control of motor starters, solenoid valves, and contactors\u003c\/li\u003e\n\u003cli\u003eInterface between controller logic and high-voltage field devices\u003c\/li\u003e\n\u003cli\u003eAlarm and status indicator activation\u003c\/li\u003e\n\u003cli\u003eDiscrete output control in PLC or DCS-based automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900H01-0202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e8 Relays (4 Form A, 4 Form C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e4 A @ 240 Vac \/ 30 Vdc (Resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Device\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e11 ms (OFF to ON) \/ 8 ms (ON to OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loading\u003c\/td\u003e\n\u003ctd\u003e5V @ 110 mA; 24V @ 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Life\u003c\/td\u003e\n\u003ctd\u003e10^5 Electrical \/ 5 x 10^7 Mechanical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137mm H x 35.6mm W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.425 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Suppression:\u003c\/strong\u003e When switching inductive loads (such as coils or solenoids), ensure external snubber circuits or flyback diodes are installed to protect the relay contacts from arcing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module firmly into the rack backplane; ensure the connector is fully seated to prevent intermittent contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Keep AC and DC wiring separated in the cabinet to reduce cross-talk and potential noise induction into the logic side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Due to the electromechanical nature of the relays, schedule periodic operational checks to verify contact integrity, especially in high-vibration applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e Ensure the cabinet environment remains within specified temperature limits, as relay contact resistance can increase with elevated temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705609613675,"sku":"900H01-0202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900h01-0202-z00tmrrsxss_ae4227f3-5acb-457e-85e5-b90a641b6535.jpg?v=1766651604"},{"product_id":"honeywell-900g32-0301-digital-input-24-vdc-module","title":"Honeywell 900G32-0301 Digital Input 24 VDC Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900G32-0301\u003c\/strong\u003e is a high-density \u003cstrong\u003eDigital Input Module\u003c\/strong\u003e engineered for the ControlEdge HC900 system, providing 32 sinking input channels. This module is designed to monitor a wide range of 24 Vdc field signals, offering robust performance in harsh industrial environments with an extended operating temperature range. With integrated galvanic isolation split into two groups of 16, this module effectively separates field-side electrical activity from the internal backplane, enhancing system reliability and protecting critical control components from voltage transients.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Channel Density:\u003c\/strong\u003e 32 sinking input channels per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Range:\u003c\/strong\u003e Compatible with signal voltages from 10 Vdc to 32 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Two isolated groups of 16 inputs for enhanced noise immunity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Response:\u003c\/strong\u003e Consistent 5 ms response time for both ON-to-OFF and OFF-to-ON transitions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Thermal Specs:\u003c\/strong\u003e Certified for extended operation from -40 degC to 70 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote monitoring of digital sensors, limit switches, and contact closures\u003c\/li\u003e\n\u003cli\u003eHigh-density I\/O acquisition for DCS or PLC architectures\u003c\/li\u003e\n\u003cli\u003eSafety-related process interlock monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery diagnostic feedback loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900G32-0301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input 24 Vdc Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs per Module\u003c\/td\u003e\n\u003ctd\u003e32 (sinking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10 Vdc to 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e2 groups of 16 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Voltage Level\u003c\/td\u003e\n\u003ctd\u003e9.5 Vdc (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Voltage Level\u003c\/td\u003e\n\u003ctd\u003e3.5 Vdc (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e6.9 K ohms (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e5 ms (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp.\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating:\u003c\/strong\u003e Insert the module into the HC900 rack carefully to ensure the backplane pins are not bent; ensure the locking mechanism is fully engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSinking Configuration:\u003c\/strong\u003e Ensure field devices are wired for a sinking configuration, where the module provides the ground path for the input signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Management:\u003c\/strong\u003e Distribute field wiring to respect the two isolated groups of 16 inputs to maintain the electrical integrity provided by the module design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e The module supports extended operating temperatures; however, ensure adequate airflow within the cabinet to prevent localized hot spots that may exceed the 70 degC limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e For inputs routed through long cable runs, utilize shielded twisted-pair cabling and bond the shield to the common ground at the cabinet entry point.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705611055467,"sku":"900G32-0301","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900g32-0301-zqy1ar5islm_f1e36db5-9437-4722-b735-c3dd2df61170.jpg?v=1766651658"},{"product_id":"honeywell-900p24-0101-controledge-hc900-expansion-processor-module","title":"Honeywell 900P24-0101 ControlEdge HC900 Expansion Processor Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900P24-0101\u003c\/strong\u003e is a high-performance \u003cstrong\u003eExpansion Processor Module\u003c\/strong\u003e designed for the ControlEdge HC900 system. This module serves as a critical bridge in expanding the controller’s I\/O capacity, allowing for seamless integration of remote racks and additional I\/O modules into the primary control loop. Engineered for demanding industrial environments, the \u003cstrong\u003e900P24-0101\u003c\/strong\u003e ensures stable power distribution and high-speed communication across the expansion backplane, supporting complex automation architectures that require scalable I\/O.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Scalability:\u003c\/strong\u003e Enables expansion of the HC900 system by facilitating communication with remote I\/O racks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Power Handling:\u003c\/strong\u003e Supports a wide input voltage range (21 to 29 Vdc) with a 5 A continuous current rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency:\u003c\/strong\u003e Optimized for a 72.5 W input rating with a 60 W output capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Protection:\u003c\/strong\u003e Designed to handle inrush currents of up to 30 A for 3 ms, providing resilience against power-up transients\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) for process manufacturing\u003c\/li\u003e\n\u003cli\u003eExpanded remote I\/O configurations in large-scale industrial plants\u003c\/li\u003e\n\u003cli\u003eHigh-availability automation loops requiring additional sensor and actuator connectivity\u003c\/li\u003e\n\u003cli\u003eSystem retrofitting and capacity upgrades for existing HC900 installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900P24-0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExpansion Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e21 to 29 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Continuous Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A for 3 ms @ 29 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e72.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003e60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.0 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Placement:\u003c\/strong\u003e Seat the module firmly into the designated processor slot on the expansion rack. Ensure full backplane engagement before applying power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Ensure the field power supply is stabilized within the 21–29 Vdc range to prevent operational instability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Allow for adequate ventilation in the cabinet. While the module is efficient, it must operate within standard ambient temperature limits to maintain the 60 W output rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriate wire gauges to support the 5 A continuous current rating and minimize voltage drop across the expansion lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-commissioning:\u003c\/strong\u003e Check for short circuits on the field side before powering the module to prevent triggering system-level protective shutdowns.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705612300651,"sku":"900P24-0101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900p24-0101-zqcxisdxhhj_f655737c-2ae5-4c9d-87c8-bada556f4a7e.jpg?v=1766651702"},{"product_id":"honeywell-900r08-0200-hc900-8-i-o-slot-rack","title":"Honeywell 900R08-0200 HC900 8 I\/O Slot Rack","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900R08-0200\u003c\/strong\u003e is an 8-slot \u003cstrong\u003eI\/O Rack\u003c\/strong\u003e designed for the HC900 process and logic controller system. This rack serves as the modular foundation for the controller, providing the necessary backplane connectivity for up to eight I\/O modules. It is engineered to facilitate easy assembly, allowing users to scale their control systems by integrating diverse input and output modules within a compact, centralized physical structure.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Capacity:\u003c\/strong\u003e Supports up to 8 I\/O modules, enabling flexible system configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Designed for direct compatibility with HC900 controller architectures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Engineered for space-efficient mounting within industrial control cabinets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Backplane:\u003c\/strong\u003e Provides reliable electrical and communication connectivity between the CPU and all mounted I\/O modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) for small to mid-sized industrial processes\u003c\/li\u003e\n\u003cli\u003eBatch control and furnace automation\u003c\/li\u003e\n\u003cli\u003eData acquisition and signal processing loops\u003c\/li\u003e\n\u003cli\u003eScalable automation solutions for manufacturing and chemical processing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900R08-0200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHC900 Modul 8 I\/O Slot Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e8 I\/O module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e15.17 cm x 41.91 cm x 17.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the rack horizontally within the control cabinet, ensuring adequate clearance on all sides for optimal thermal management and cabling access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the rack chassis to a clean, low-impedance earth ground to ensure proper noise immunity and safety compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating:\u003c\/strong\u003e Insert modules into the slots with care; ensure they are fully seated and locked into the backplane connectors before powering up the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Install the rack in a location free from excessive dust, moisture, and corrosive vapors to prevent degradation of the backplane connectors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705613906283,"sku":"900R08-0200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900r08-0200-2lqf4f3na5m_031285f6-58bf-4b74-be64-579c9a4fc968.jpg?v=1766651763"},{"product_id":"honeywell-900g01-0202-digital-input-module","title":"Honeywell 900G01-0202 Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900G01-0202\u003c\/strong\u003e is a high-density \u003cstrong\u003eDigital Input Module\u003c\/strong\u003e designed for precision signal monitoring within industrial control systems. This module features 16 single-ended input channels, providing reliable sensing and interface capability for field devices. It is engineered with integral galvanic isolation to protect the internal controller and backplane circuitry from field-side electrical transients, ensuring robust operation in demanding automation environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Density:\u003c\/strong\u003e 16 single-ended input channels per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Enhanced protection between field wiring and internal microcontroller\/backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Response Times:\u003c\/strong\u003e Optimized for rapid signal status changes (4 ms OFF-to-ON, 6 ms ON-to-OFF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Efficient power supply loading on both 5V and 24V rails\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStatus monitoring of limit switches, pushbuttons, and proximity sensors\u003c\/li\u003e\n\u003cli\u003eDiscrete signal acquisition in PLC or DCS architectures\u003c\/li\u003e\n\u003cli\u003eSafety and process interlock monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery control and diagnostic feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900G01-0202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs per module\u003c\/td\u003e\n\u003ctd\u003e16 (single-ended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Supplied\u003c\/td\u003e\n\u003ctd\u003e15 Vdc nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Contact Resistance\u003c\/td\u003e\n\u003ctd\u003e1000 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF to ON Response\u003c\/td\u003e\n\u003ctd\u003e4 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON to OFF Response\u003c\/td\u003e\n\u003ctd\u003e6 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Current\u003c\/td\u003e\n\u003ctd\u003e2.6 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loading\u003c\/td\u003e\n\u003ctd\u003e5V @ 130 mA max; 24V @ 40 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137mm H x 35.6mm W (5.4in H x 1.4in W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.354 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the module into the designated slot on the system backplane, ensuring proper alignment to prevent pin damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain consistent system-wide grounding to ensure the effectiveness of the galvanic isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Keep input field wiring away from high-voltage AC lines to prevent crosstalk and noise injection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity:\u003c\/strong\u003e Ensure correct polarity during field device connection, as the module requires a 15 Vdc nominal supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the module operates within the manufacturer-specified thermal range to guarantee the rated response times.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705618002283,"sku":"900G01-0202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900g01-0202-5ukgw5rics4_0e523a74-ebde-42f4-b37d-264de361ee0b.jpg?v=1766651911"},{"product_id":"honeywell-900u01-0100-universal-i-o-module","title":"Honeywell 900U01-0100 Universal I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900U01-0100\u003c\/strong\u003e is a \u003cstrong\u003eUniversal I\/O (UIO) Module\u003c\/strong\u003e designed for the ControlEdge 900 platform. This versatile module provides \u003cstrong\u003e16 channels\u003c\/strong\u003e that can be independently configured as analog inputs, analog outputs, digital inputs, or digital outputs. By offering software-selectable channel types, the 900U01-0100 significantly reduces spare part inventory and simplifies system design, as a single module can accommodate various signal types required by different field devices.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware-Configurable Channels:\u003c\/strong\u003e Each of the 16 channels can be configured for analog or digital, input or output, via software, eliminating the need for hard-wired configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncreased Flexibility:\u003c\/strong\u003e Simplifies engineering, installation, and commissioning by allowing changes to I\/O types late in the project cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Inventory:\u003c\/strong\u003e Minimizes the need to stock multiple types of I\/O modules, as one part number covers diverse signal requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Optimized for the high-density ControlEdge 900 platform architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) and SCADA applications\u003c\/li\u003e\n\u003cli\u003eMixed-signal environments requiring versatile I\/O points\u003c\/li\u003e\n\u003cli\u003eRetrofit projects where field wiring requirements may be uncertain\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose industrial automation and process monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e900U01-0100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUniversal I\/O (UIO) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSoftware-selectable (AI, AO, DI, DO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the module is properly seated in the designated I\/O carrier slot for the ControlEdge 900 platform.\u003c\/li\u003e\n\u003cli\u003eSince channels are software-configured, verify that the I\/O mapping in your controller configuration matches the actual field wiring before energizing.\u003c\/li\u003e\n\u003cli\u003eUtilize the appropriate terminal block assembly for the UIO module to ensure reliable connections for various signal types.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) precautions during handling to protect the sensitive internal circuitry.\u003c\/li\u003e\n\u003cli\u003eDocument all channel configurations in the project design files to prevent accidental reconfiguration during maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705759691115,"sku":"900U01-0100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900u01-0100-y4mvev2srua_8963fb1d-9d56-4143-893a-08899efb5936.jpg?v=1766659386"},{"product_id":"honeywell-900g02-0102-16-channel-24-vdc-digital-input-module","title":"Honeywell 900G02-0102 16 Channel 24 Vdc Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900G02-0102\u003c\/strong\u003e is a \u003cstrong\u003e16 Channel 24 Vdc Digital Input Module\u003c\/strong\u003e designed for high-density signal acquisition within industrial automation systems. This module enables the interface between field devices—such as pushbuttons, limit switches, or proximity sensors—and the control system by converting discrete binary signals into data packets. Engineered for reliable operation in demanding industrial environments, the \u003cstrong\u003e900G02-0102\u003c\/strong\u003e provides the necessary I\/O capacity to support complex logic operations and monitoring tasks within Honeywell control architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-channel discrete input capacity\u003c\/strong\u003e for efficient signal consolidation\u003c\/li\u003e\n\u003cli\u003eStandard \u003cstrong\u003e24 Vdc\u003c\/strong\u003e input compatibility\u003c\/li\u003e\n\u003cli\u003eDesigned for high-reliability industrial data acquisition\u003c\/li\u003e\n\u003cli\u003eModular form factor compatible with standard Honeywell I\/O racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) monitoring\u003c\/li\u003e\n\u003cli\u003eMachine control and status tracking\u003c\/li\u003e\n\u003cli\u003eIndustrial proximity and limit switch integration\u003c\/li\u003e\n\u003cli\u003eSafety-related signal monitoring in automated production lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e900G02-0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e16 Channel 24 Vdc Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDigital (Discrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the control cabinet is de-energized before mounting the module to the backplane.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 Vdc power supply is properly regulated to match the module's input requirements.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded cables for long-distance runs to minimize noise interference on the digital signal lines.\u003c\/li\u003e\n\u003cli\u003eMaintain proper terminal torque settings during wiring to prevent loose connections or intermittent signal loss.\u003c\/li\u003e\n\u003cli\u003eConfigure the channel mapping in the control software according to the specific wiring assignments for the 16 channels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705766867307,"sku":"900G02-0102","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900G02-0102-g23ukqezqls_1a20a562-0229-4644-817b-669906c6ff55.jpg?v=1766659490"},{"product_id":"900h02-0102-honeywell-controledge-hc900-digital-output-module","title":"900H02-0102 Honeywell ControlEdge HC900 Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e900H02-0102 (900H02-0102)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell ControlEdge HC900 Digital Output Module delivers 16-channel low side switching control for industrial automation systems. It operates with externally powered field loads and supports two isolated groups of eight outputs. Each group provides independent power terminals for stable distribution and fault separation. The module integrates intelligent power switching with built in electronic protection per channel. It serves continuous process industries such as oil refining, power generation, and chemical processing plants. Engineers deploy it to maintain reliable actuator control and reduce unplanned downtime in critical loops. Each channel includes LED status indication for real time diagnostics and fault visibility. The module supports fast response switching for high speed control applications. It also maintains stable operation under electrical stress and thermal variation. The design improves system uptime through automatic overload limitation and diagnostic reporting. It fits seamlessly into Honeywell HC900 ControlEdge architectures for scalable distributed control.\u003c\/p\u003e\n\u003ch3\u003eCore Architecture and Electrical Design\u003c\/h3\u003e\n\u003cp\u003eThe module uses two isolated output banks to reduce fault propagation risk. Each bank supports eight current sinking outputs with shared field supply terminals. Intelligent power switches manage overload and temperature protection per channel. Internal diagnostics continuously monitor module health and output behavior. LED indicators provide direct visualization of channel activity and system status. The design ensures compatibility with standard DC industrial loads and actuators. It supports inductive and resistive loads within defined electrical limits. Backplane communication integrates with HC900 controller scan cycles for synchronized control execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900H02-0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 (2 x 8 isolated groups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking, low side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e6.5 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Voltage\u003c\/td\u003e\n\u003ctd\u003e34 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.3 VDC at 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current\u003c\/td\u003e\n\u003ctd\u003e1 A per point, 8 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e0.15 mA at 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e6 ms ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 340 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 900H02-0102 compatible with all HC900 controllers?\u003c\/strong\u003e\u003cbr\u003eIt is fully compatible with Honeywell ControlEdge HC900 system architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens during output overload conditions?\u003c\/strong\u003e\u003cbr\u003eEach channel shuts down electronically and requires power cycle reset.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it drive inductive loads like solenoids?\u003c\/strong\u003e\u003cbr\u003eYes, within specified current and inductance limits up to 5 mH.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support redundancy?\u003c\/strong\u003e\u003cbr\u003eIt supports isolated groups but not full module redundancy by itself.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e900H02-0102 (900H02-0102)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell ControlEdge HC900 Digital Output Module delivers 16-channel low side switching control for industrial automation systems. It operates with externally powered field loads and supports two isolated groups of eight outputs. Each group provides independent power terminals for stable distribution and fault separation. The module integrates intelligent power switching with built in electronic protection per channel. It serves continuous process industries such as oil refining, power generation, and chemical processing plants. Engineers deploy it to maintain reliable actuator control and reduce unplanned downtime in critical loops. Each channel includes LED status indication for real time diagnostics and fault visibility. The module supports fast response switching for high speed control applications. It also maintains stable operation under electrical stress and thermal variation. The design improves system uptime through automatic overload limitation and diagnostic reporting. It fits seamlessly into Honeywell HC900 ControlEdge architectures for scalable distributed control.\u003c\/p\u003e\n\u003ch3\u003eCore Architecture and Electrical Design\u003c\/h3\u003e\n\u003cp\u003eThe module uses two isolated output banks to reduce fault propagation risk. Each bank supports eight current sinking outputs with shared field supply terminals. Intelligent power switches manage overload and temperature protection per channel. Internal diagnostics continuously monitor module health and output behavior. LED indicators provide direct visualization of channel activity and system status. The design ensures compatibility with standard DC industrial loads and actuators. It supports inductive and resistive loads within defined electrical limits. Backplane communication integrates with HC900 controller scan cycles for synchronized control execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900H02-0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 (2 x 8 isolated groups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking, low side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e6.5 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Voltage\u003c\/td\u003e\n\u003ctd\u003e34 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.3 VDC at 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current\u003c\/td\u003e\n\u003ctd\u003e1 A per point, 8 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e0.15 mA at 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e6 ms ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 340 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 900H02-0102 compatible with all HC900 controllers?\u003c\/strong\u003e\u003cbr\u003eIt is fully compatible with Honeywell ControlEdge HC900 system architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens during output overload conditions?\u003c\/strong\u003e\u003cbr\u003eEach channel shuts down electronically and requires power cycle reset.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it drive inductive loads like solenoids?\u003c\/strong\u003e\u003cbr\u003eYes, within specified current and inductance limits up to 5 mH.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support redundancy?\u003c\/strong\u003e\u003cbr\u003eIt supports isolated groups but not full module redundancy by itself.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the module in a grounded control cabinet to reduce electrical noise. Maintain proper separation between field wiring and signal wiring. Use shielded cables for inductive load circuits in high interference environments. Ensure torque tightening follows Honeywell cabinet wiring standards. Verify external power supply stability before commissioning. Avoid exceeding 8 A total module load to prevent thermal stress. In high vibration environments, secure terminal blocks with periodic inspection. Maintain airflow around racks to control internal temperature rise.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705777746283,"sku":"900H02-0102","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900H02-0102-am2udww5qrx_1ee7cfb6-a929-4b4d-9e27-c6ab65a3a84c.jpg?v=1766659687"},{"product_id":"honeywell-900c30s-0460-cpu-controledge-900","title":"Honeywell 900C30S-0460 CPU, ControlEdge 900","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900C30S-0460\u003c\/strong\u003e is a high-performance \u003cstrong\u003eCPU Processor module\u003c\/strong\u003e designed for the \u003cstrong\u003eControlEdge 900\u003c\/strong\u003e series. Functioning as the core of a \u003cstrong\u003eProgrammable Logic Controller (PLC)\u003c\/strong\u003e, this C30 CPU provides robust logic execution and extensive I\/O management capabilities. It is engineered for demanding industrial control applications, offering versatile communication protocols and high-density connection capacity to support complex automation architectures. The \u003cstrong\u003e900C30S-0460\u003c\/strong\u003e is technically compatible with the \u003cstrong\u003eHC900 Series\u003c\/strong\u003e, ensuring integration flexibility within existing Honeywell control infrastructures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentral processing unit for \u003cstrong\u003eControlEdge 900 PLC\u003c\/strong\u003e systems\u003c\/li\u003e\n\u003cli\u003eSupports extensive I\/O: up to 192 analog inputs and 384 digital inputs (expandable via UOI)\u003c\/li\u003e\n\u003cli\u003eVersatile communication: \u003cstrong\u003eModbus TCP\u003c\/strong\u003e, \u003cstrong\u003eModbus RTU\u003c\/strong\u003e, \u003cstrong\u003eEthernet\/IP\u003c\/strong\u003e, \u003cstrong\u003ePROFIBUS\u003c\/strong\u003e, and \u003cstrong\u003eRS-485\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMemory: 400 function blocks with 64MB RAM\u003c\/li\u003e\n\u003cli\u003eBackplane\/rack-mounted modular design\u003c\/li\u003e\n\u003cli\u003eHazardous location rated for Class 1 Zone 2 environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) and PLC process control\u003c\/li\u003e\n\u003cli\u003eManufacturing automation and assembly lines\u003c\/li\u003e\n\u003cli\u003eInfrastructure management requiring \u003cstrong\u003eModbus\u003c\/strong\u003e and \u003cstrong\u003eEthernet\/IP\u003c\/strong\u003e connectivity\u003c\/li\u003e\n\u003cli\u003eHazardous location industrial process monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e900C30S-0460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCPU, ControlEdge 900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e1100mA (system supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e400 function blocks, 64MB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, Modbus RTU, Ethernet\/IP, PROFIBUS, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45, removable terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137mm H x 38.1mm W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the module is securely seated in the rack backplane to establish a reliable system power connection.\u003c\/li\u003e\n\u003cli\u003eObserve ambient air temperature constraints (0 to 60 Celsius) within the control cabinet to maintain operational integrity.\u003c\/li\u003e\n\u003cli\u003eFollow standard grounding practices for \u003cstrong\u003eClass I Div 2\u003c\/strong\u003e hazardous locations when installing in sensitive environments.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for \u003cstrong\u003eRS-485\u003c\/strong\u003e and \u003cstrong\u003eEthernet\u003c\/strong\u003e ports to mitigate EMI\/RFI impact on communication performance.\u003c\/li\u003e\n\u003cli\u003eVerify proper polarity for the 5Vdc system supply before powering on the rack assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE, EN61010-1\u003c\/li\u003e\n\u003cli\u003eUL 61010-1, CSA C22.2 No. 1010-1\u003c\/li\u003e\n\u003cli\u003eATEX II 3 G Ex nA IIC T4 Gc\u003c\/li\u003e\n\u003cli\u003eFM Class I Div. 2 Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003eCSA Class I Div. 2 Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003eHazardous (Classified) Location Safety Class 1 Zone 2 IIC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705781678443,"sku":"900C30S-0460","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900c30s-0460-1koyd2ldjbt_5fcd8620-cc07-4de0-a25c-4a03a7b682c3.jpg?v=1766659724"},{"product_id":"honeywell-51450991-001-switching-power-supply-900-01-0301","title":"Honeywell 51450991-001 Switching Power Supply 900-01-0301","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51450991-001\u003c\/strong\u003e is a high-reliability \u003cstrong\u003eSwitching Power Supply\u003c\/strong\u003e (Type: 900-01-0301) designed to provide stable DC power for industrial control systems. This power supply unit accepts a wide-range AC input and delivers dual-voltage DC outputs to support sensitive electronic components and logic circuitry within a control rack or enclosure. The \u003cstrong\u003e51450991-001\u003c\/strong\u003e is engineered to maintain a total continuous output power of 58W, ensuring consistent performance in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWide-range AC input voltage (90-264Vac) for global compatibility\u003c\/li\u003e\n\u003cli\u003eDual-output configuration (5Vdc and 24Vdc)\u003c\/li\u003e\n\u003cli\u003e58W total continuous output power capacity\u003c\/li\u003e\n\u003cli\u003eRobust industrial-grade design for standard rack mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) power distribution\u003c\/li\u003e\n\u003cli\u003eIndustrial automation control panels\u003c\/li\u003e\n\u003cli\u003ePLC and I\/O module power supply systems\u003c\/li\u003e\n\u003cli\u003eSignal conditioning and interface modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e51450991-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e900-01-0301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitching Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e90-264Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e1.4A Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput 1\u003c\/td\u003e\n\u003ctd\u003e5Vdc \/ 6A Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput 2\u003c\/td\u003e\n\u003ctd\u003e24Vdc \/ 2A Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Power\u003c\/td\u003e\n\u003ctd\u003e58W continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the power supply is mounted in an enclosure that provides adequate airflow to maintain the specified operating temperature range of 0-60 Celsius.\u003c\/li\u003e\n\u003cli\u003eVerify that the input AC supply lines are properly fused according to local electrical codes.\u003c\/li\u003e\n\u003cli\u003eEnsure all DC output connections are tightly secured to prevent voltage drops or intermittent connectivity.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance around the unit to ensure effective heat dissipation.\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire gauges for input and output connections to handle the rated current capacity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705782497643,"sku":"51450991-001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/51450991-001-lpqulmzag41_7774a218-3e4d-4ce5-acf4-6c071c7e02b9.jpg?v=1766659748"},{"product_id":"honeywell-900c50-0460-00-controledge-900-plc-cpu-module","title":"Honeywell 900C50-0460-00 ControlEdge 900 PLC CPU Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003e\u003cstrong\u003e900C50-0460-00\u003c\/strong\u003e \u003c\/span\u003eis the high-performance \u003cstrong\u003eControlEdge 900 CPU\u003c\/strong\u003e developed by \u003cspan\u003eHoneywell\u003c\/span\u003e to serve as the core controller for the ControlEdge PLC platform. Engineered for the \"Industrial Internet of Things\" (IIoT) era, this CPU provides powerful processing capabilities for \u003cspan\u003eoil and gas, water\/wastewater, and energy management\u003c\/span\u003e applications. The \u003cspan\u003e900C50-0460-00\u003c\/span\u003e excels in integrating seamlessly with Honeywell Experion systems, offering native support for the OPC UA protocol and ensuring secure, high-speed data exchange. By utilizing a common engineering environment across the ControlEdge family, this CPU reduces commissioning complexity and provides a scalable, future-proof solution for critical process control and safety-related logic.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data Matrix (Parameter Priority)\u003c\/h3\u003e\n\u003cp\u003eThe following table encapsulates the essential physical and operational specifications of the \u003cspan\u003e900C50-0460-00\u003c\/span\u003e to ensure precise engineering alignment and asset management.\u003c\/p\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eTechnical Parameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e900C50-0460-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlEdge 900 CPU Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Ethernet Ports (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOPC UA, Modbus TCP, EtherNet\/IP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCybersecurity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISASecure EDSA Certified Level 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e137 mm (5.4 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWidth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e38.1 mm (1.5 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.36 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, ATEX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations \u0026amp; Control Strategy FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eWhat makes the ControlEdge 900C50-0460-00 suitable for IIoT applications?\u003c\/span\u003eThe \u003cspan\u003e900C50-0460-00\u003c\/span\u003e is natively built with \u003cspan\u003eOPC UA\u003c\/span\u003e communication capabilities. This allows the CPU to communicate directly with cloud-based analytics platforms and enterprise-level software without the need for intermediate gateways, simplifying the data-to-decision pipeline.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDoes this CPU support redundant configurations for high-availability systems?\u003c\/span\u003eYes. The \u003cspan\u003eControlEdge 900\u003c\/span\u003e architecture allows for redundant CPU pairings. In a redundant setup, if the primary \u003cspan\u003e900C50-0460-00\u003c\/span\u003e fails, the secondary module takes over logic execution and communication in a \"bumpless\" transfer, ensuring no interruption to the industrial process.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHow is the module protected against cyber threats?\u003c\/span\u003eHoneywell has designed the \u003cspan\u003e900C50-0460-00\u003c\/span\u003e with \"Security by Design.\" It is \u003cspan\u003eISASecure Level 2\u003c\/span\u003e certified, featuring built-in secure boot, encrypted communication, and hardened network interfaces to prevent unauthorized access to the control logic.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Protocol\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBackplane Integration:\u003c\/span\u003e The \u003cspan\u003e900C50-0460-00\u003c\/span\u003e is designed for hot-swappable installation into the ControlEdge PLC rack. Ensure the locking tabs are fully engaged to prevent intermittent power loss due to vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNetwork Topology:\u003c\/span\u003e When utilizing the dual Ethernet ports for redundancy, ensure they are connected to independent managed switches. This physical separation prevents a single switch failure from isolating the CPU from the DCS (Distributed Control System) or HMI network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThermal Management:\u003c\/span\u003e While rated for operation up to \u003cspan\u003e70 deg Celsius\u003c\/span\u003e, maintain a minimum vertical clearance of 50 mm above and below the CPU rack. This allows for natural convection cooling, which is vital for maintaining the lifespan of the internal high-speed processors during heavy logic execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages \u0026amp; System Resilience\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell 900C50-0460-00\u003c\/span\u003e stands as a robust solution for modernizing legacy automation systems. Its compact \u003cspan\u003e38.1 mm\u003c\/span\u003e width allows for high-density controller layouts, saving expensive cabinet space. As an \u003cspan\u003eOriginal and New\u003c\/span\u003e component, it provides the deterministic performance required for complex PID loops and high-speed discrete control. The module's wide operating temperature range and G3 conformal coating (optional for some variants) make it highly resilient to corrosive atmospheres typically found in \u003cspan\u003echemical processing\u003c\/span\u003e environments, ensuring the 900C50 series remains a reliable asset throughout its long operational lifecycle.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705782727019,"sku":"900C50-0460-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900c50-0460-00-d2osezntjtk.jpg?v=1765951921"},{"product_id":"900c30-0460-honeywell-controledge-hc900-c30-cpu-processor","title":"900C30-0460 Honeywell ControlEdge HC900 C30 CPU Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900C30-0460\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCentral Processing Unit (CPU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell ControlEdge HC900\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. Functioning as a versatile Programmable Logic Controller (PLC) processor, the C30 is engineered to handle both discrete and process control applications. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e64MB of RAM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand the capacity to manage up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e400 function blocks\u003c\/strong\u003e, this CPU provides a unified control environment for medium-scale industrial processes. It is particularly valued in the power, water, and manufacturing sectors for its ability to integrate complex logic with advanced PID control in a single, compact module.\u003c\/p\u003e\n\u003ch3\u003eFunctional Intelligence \u0026amp; Versatility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell C30 CPU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for seamless integration within the HC900 modular rack system. It supports an extensive range of communication protocols, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP, Modbus RTU, and Ethernet\/IP\u003c\/strong\u003e, ensuring easy connectivity with SCADA systems and HMI interfaces. The processor’s ability to manage up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e192 analog inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e384 digital I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epoints makes it a robust solution for monitoring and controlling diversified field devices. Its high-speed logic execution combined with a wide operating temperature range (\u003cstrong\u003e0 to +60 °C\u003c\/strong\u003e) ensures reliable performance in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e900C30-0460\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlEdge HC900\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 MB (RAM) \/ 400 Function Blocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Vdc (via Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1100 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45 (Modbus TCP, Ethernet\/IP, RS-485, Profibus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e192 Analog Inputs \/ 384 Digital I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX II 3 G Ex nA, FM Class I Div 2, CE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e137mm H x 38.1mm W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg (Net) \/ 2 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the C30 differ from other CPUs in the HC900 series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900C30-0460\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for medium-scale applications. While it shares the same programming environment as the C50 or C70, the C30 provides a cost-effective balance of memory and I\/O capacity, specifically targeting systems that require fewer than 400 function blocks without compromising on industrial-grade safety and communication standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the ATEX and FM Class I Div 2 certifications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese certifications confirm that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900C30-0460\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis safe for use in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous (Classified) Locations\u003c\/strong\u003e. It is specifically tested for Zone 2 and Division 2 environments (Groups A, B, C, and D), where flammable gases or vapors may be present, making it ideal for oil \u0026amp; gas and chemical processing applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the C30 CPU be hot-swapped?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the HC900 system supports modularity, the CPU is the \"brain\" of the rack. Replacing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900C30-0460\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically requires the rack to be powered down or placed in a safe state to prevent logic interruptions. Always verify that the configuration and firmware versions match before attempting a replacement to ensure immediate system synchronization.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the module is firmly seated into the dedicated CPU slot of the HC900 backplane. Improper seating can lead to communication timeouts or system fault codes (Current consumption is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1100mA\u003c\/strong\u003e, so ensure the power supply module is appropriately sized).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the Honeywell Hybrid Control Designer (HCD) software to verify the firmware version of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900C30-0460\u003c\/strong\u003e. For B2B maintenance, it is critical to keep a backup of the control strategy on a PC or external storage, as the 64MB RAM is volatile without proper system power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the RJ45 Ethernet port for Modbus TCP or Ethernet\/IP, use industrial-grade shielded twisted pair (STP) cables to protect the control signal from electromagnetic interference (EMI) commonly found in motor control centers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900C30-0460\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents a highly scalable and resilient control solution. Its compliance with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEN61010-1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUL 61010-1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandards ensures it meets the highest safety requirements for industrial measurement and control equipment. For B2B procurement, sourcing an original Honeywell C30 CPU provides the longevity and technical support necessary to maintain critical infrastructure, offering a reliable path for both new installations and legacy system upgrades within the HC900 family.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705788559723,"sku":"900C30-0460","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900c30-0460-fff44v2nrjj_ba369787-f44f-457e-9a0d-43052771e277.jpg?v=1766659855"}],"url":"https:\/\/www.plcprotech.com\/collections\/honeywell-controledge-hc900-plc.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}