{"title":"I\/O Modules","description":"\u003cp\u003eI\/O Modules bridge the gap between physical field devices and the digital control environment of a PLC or DCS. The system architecture consists of isolated input channels for sensors and output channels for actuators, often housed in ruggedized, hot-swappable enclosures. Technical characteristics include optical isolation for circuit protection, varying voltage ranges (AC\/DC), and high-density channel configurations. Functionally, these modules convert analog or discrete electrical signals into data packets for the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/cpus\"\u003eCPU\u003c\/a\u003e to process. By utilizing modular \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/iota-bases\"\u003eIOTA and bases\u003c\/a\u003e, they enable flexible system expansion and simplified field wiring, ensuring precise monitoring and control of industrial machinery and process loops.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-289837-01-3500-encore-proximitor-seismic-i-o-module","title":"Bently Nevada 289837-01 3500 ENCORE Proximitor\/Seismic I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Proximitor\/Seismic I\/O Module designed specifically for the Bently Nevada 3500 ENCORE Machinery Protection System. This module serves as the critical rear-panel interface for the 3500\/42E Vibration Monitor, facilitating the connection of up to four channels of proximity or seismic transducers. Deployed extensively in power generation, oil and gas, and mining sectors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables the monitoring of vital machinery parameters including radial vibration, thrust position, and eccentricity. By providing reliable signal conditioning and transmission to the main processor, this I\/O module ensures continuous machinery protection and high-fidelity data acquisition. It is an essential component for facilities transitioning from legacy 3300 systems to the ENCORE platform, allowing for modernized vibration monitoring without sacrificing the integrity of field wiring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O module is engineered to support the dual-architecture capabilities of the 3500 ENCORE series, ensuring maximum flexibility for vibration and position monitoring.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFour-Channel Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilized in a standard 3500 ENCORE System Rack, the module supports four independent channels, programmed in pairs (Channels 1 \u0026amp; 2; Channels 3 \u0026amp; 4) to perform specific monitoring functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with a wide array of sensors, including proximity probes for fluid-film bearing measurements and seismic transducers (accelerometers or velocity sensors) for casing vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn a 3500 ENCORE System configuration, the I\/O module interfaces with logic-programmable Relay Modules to drive machinery trip circuits based on user-defined Alert and Danger setpoints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConditioning Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel processes raw transducer signals into \"static values,\" providing operations personnel with real-time machinery health diagnostics for both steady-state and transient conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e289837-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 ENCORE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor\/Seismic I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels (System Mode) \/ 2 Channels (Rack Upgrade)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 percent non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.68 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208.28 mm x 48.26 mm x 127 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 289837-01 be used as a direct spare for 3300 series I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the 3500 ENCORE system is designed to upgrade 3300 monitors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically intended for use in the 3500 ENCORE System Rack. For \"Rack Upgrade\" configurations where the 3300 chassis remains, the system utilizes the pre-existing 3300 series I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this I\/O module support both radial vibration and thrust position simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Since channels are programmed in pairs, you can configure Channels 1 and 2 for radial vibration while Channels 3 and 4 are configured for thrust position (or any other supported function) within the same 3500\/42E monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle signal faults such as a disconnected sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/42E monitor, interfacing through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e, continuously performs self-tests. If a transducer signal fails or field wiring is compromised, the monitor will flag a \"Not OK\" status, preventing false trips and alerting maintenance via the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering and Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting Proximitor or Seismic sensors to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminals, ensure that cable shields are terminated only at the I\/O module ground. Do not ground shields at the transducer end to prevent ground loops, which can introduce noise and compromise vibration measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Torquing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the I\/O module is fully seated into the rear of the ENCORE rack and that the mounting screws are tightened to secure the module against the backplane. This is critical for maintaining signal integrity in high-vibration environments typical of compressor decks or turbine halls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the module is rated for up to 95 percent non-condensing humidity, it should always be installed in a NEMA 4 or IP65 rated enclosure if located in areas with high moisture or corrosive chemicals. Ensure adequate airflow within the rack to maintain the operating temperature below the 65 deg C threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAfter replacing an I\/O module, always use the 3500 Rack Configuration Software to verify that the channel pairings and transducer types match the field-installed sensors. Perform a loop check to ensure that Alert and Danger setpoints are correctly driving the associated Relay Modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516898155,"sku":"3500\/42E 289837-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42e-289837-01-vibration-monitor-5lwybpzw3c4_d9f2ca71-9841-4ea7-b237-17c1fd8f0f71.jpg?v=1765440098"},{"product_id":"bently-nevada-133819-02-3500-61-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 133819-02 3500\/61 RTD\/TC Non-Isolated I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eBently Nevada \u003cstrong\u003e133819-02\u003c\/strong\u003e\u003c\/span\u003e is a specialized \u003cspan\u003eRTD\/TC Non-Isolated I\/O Module\u003c\/span\u003e designed for the \u003cstrong\u003e3500\/61 Temperature Monitor.\u003c\/strong\u003e This module provides the physical interface for six channels of temperature monitoring, supporting both Resistance Temperature Detectors (RTD) and Thermocouples (TC). The \u003cspan\u003e133819-02\u003c\/span\u003e features \u003cspan\u003eInternal Terminations\u003c\/span\u003e, allowing field wiring to connect directly to the terminal blocks on the I\/O module itself. This non-isolated version offers maximum flexibility, permitting users to configure the module for TC, RTD, or a mixture of both sensor types across its six channels.\u003c\/p\u003e\n\u003ch3\u003eFunctional Intelligence \u0026amp; Recorder Outputs\u003c\/h3\u003e\n\u003cp\u003eAs a \u003cspan\u003e3500\/61\u003c\/span\u003e series component, this I\/O module includes dedicated \u003cspan\u003erecorder outputs\u003c\/span\u003e for each of its six channels. It provides a \u003cspan\u003e+4 to +20 mA\u003c\/span\u003e signal proportional to the monitor's full-scale range, enabling seamless integration with external control systems, DCS, or chart recorders for data logging. The module's architecture is fault-tolerant; monitor operation remains unaffected by short circuits on the recorder outputs, ensuring that the primary machinery protection functions remain active.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e133819-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMonitor Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500\/61\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 (Individually programmable for RTD or TC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTermination Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Terminations (On-module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-Isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTD Current Source\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 15 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA @ 25 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecorder Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+4 to +20 mA (Load: 0 to 600 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΩ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy (Internal)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 3 °C @ 25 °C (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 5.4 °F @ 77 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C to +65 °C (-22 °F to +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg (1.0 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (HxWxD)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 99.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the main difference between the 3500\/60 and 3500\/61 modules?\u003c\/span\u003eBoth modules provide identical six-channel temperature monitoring functionality. However, the \u003cspan\u003e3500\/61\u003c\/span\u003e (which uses the \u003cspan\u003e133819-02\u003c\/span\u003e I\/O) includes 4-20 mA recorder outputs for each channel, whereas the 3500\/60 does not provide these analog outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan I mix different sensor types on a single 133819-02 module?\u003c\/span\u003eYes. Unlike the isolated versions, this non-isolated I\/O module can be configured via the \u003cspan\u003e3500 Rack Configuration Software\u003c\/span\u003e to accept any combination of TC and RTD inputs across its six channels.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHow does the module handle RTD wiring?\u003c\/span\u003eThe module provides a specialized current source of \u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA\u003c\/span\u003e. It is designed to support 3-wire RTDs (using two current supplies for lead-wire compensation) and 4-wire RTDs (using a single supply), ensuring accurate temperature measurement across various transducer types.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInternal Termination Management:\u003c\/span\u003e The \u003cspan\u003e133819-02\u003c\/span\u003e utilizes internal terminal blocks. Ensure that field wiring is properly labeled and securely fastened to prevent intermittent signals, which could trigger \"Bypass\" or \"Error\" status LEDs on the front panel of the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironmental Considerations:\u003c\/span\u003e The module is rated for an operating temperature range of \u003cspan\u003e-30 °C to +65 °C\u003c\/span\u003e. For installations in extreme environments, ensure the 3500 rack has adequate ventilation to maintain these limits and prevent accuracy drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTMR Configuration:\u003c\/span\u003e When used in Triple Modular Redundant (TMR) applications, three temperature monitors must be installed in adjacent groups. The system employs two types of voting to prevent single-point failures from causing false trips in critical machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eBently Nevada 133819-02\u003c\/span\u003e provides a cost-effective, high-density solution for machinery temperature protection. By combining TC and RTD support into a single module with internal terminations, it reduces cabinet space and simplifies wiring complexity. For B2B procurement, choosing the original \u003cspan\u003e133819-02\u003c\/span\u003e ensures full compatibility with the \u003cspan\u003e3500 Monitoring System\u003c\/span\u003e, maintaining the high accuracy and ruggedness required for protecting turbines, compressors, and large industrial motors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518864235,"sku":"133819-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133819-02-rtd-tc-temp-i-o-module-olhm4jqsb0w_ea2a25c8-3e12-4f5e-a5c2-4a168d80f750.jpg?v=1765440121"},{"product_id":"bently-nevada-133442-01-3500-50m-i-o-module-with-internal-terminations","title":"Bently Nevada 133442-01 3500\/50M I\/O Module with Internal Terminations","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel Tachometer Input\/Output (I\/O) module designed for the 3500 Series Machinery Protection System. This module serves as the primary physical interface for field wiring, specifically engineered to operate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTachometer Main Modules. It processes high-frequency pulse inputs from proximity probes or passive magnetic pickups to facilitate precise measurements of rotational speed, rotor acceleration, and reverse rotation.\u003c\/p\u003e\n\u003cp\u003eAs an internal termination variant, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures integrated screw terminal blocks directly on the module body, optimizing it for high-density cabinet installations where space is a priority. This hardware configuration is widely deployed in power generation, petrochemical, and gas compression facilities for continuous machinery monitoring and critical overspeed protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTachometer I\/O Module with Internal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-channel differential or single-ended pulse inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity probe systems, Magnetic pickups\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+10.0 Vdc to -24.0 Vdc (internally limited)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.15 kΩ (Internal Barrier variant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 163.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 kg (1.01 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 deg C to +65 deg C (-22 deg F to +149 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eWhen procuring spare parts, ensure the part number matches the specific rack configuration to avoid hardware\/software mismatch errors.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComponent Description\u003c\/strong\u003e: 3500\/50M Tachometer I\/O Module with Internal Terminations (Internal Barrier Type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAssociated Main Module\u003c\/strong\u003e: 3500\/50-01-XX or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50M-01-XX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Fixed screw terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Field Wiring Guide\u003c\/h3\u003e\n\u003ch3\u003eWiring and Shielding Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection\u003c\/strong\u003e: Use twisted, shielded pair cabling (18 AWG to 22 AWG) for all transducer connections to mitigate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Connect shields to the designated instrument ground terminal on the 3500 rack chassis at one end only. Do not ground at the field transducer to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Separation\u003c\/strong\u003e: Maintain a minimum distance of 300 mm (12 inches) between speed sensor cables and high-voltage AC power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Hot-Swap Precautions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Alignment\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be installed in the rear slot corresponding to the front-mounted 3500\/50M main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBypass Protocol\u003c\/strong\u003e: Prior to module extraction or insertion, bypass all associated machinery trip relays to prevent accidental turbine or compressor trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Limits\u003c\/strong\u003e: Tighten terminal block screws to a maximum of 0.56 N·m (5 in·lb) to protect the internal PCB traces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 133442-01 compatible with older 3500\/50 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is fully backwards compatible with standard 3500\/50 and upgraded 3500\/50M modules, provided the rack configuration software matches the hardware variant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and the External Termination (ET) version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures built-in terminal blocks. The ET version requires a multi-pin cable to connect to a remote DIN-rail terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the risks of exceeding the input signal range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile internal clipping circuits limit voltages, sustained overvoltage outside the +10V to -24V range can degrade the internal barrier circuitry and cause channel faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519650667,"sku":"133442-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133442-01-i-o-module-with-internal-terminations-1a4iq1cd4r4_bc83d92f-d0df-4c88-95ae-2fed0e219041.jpg?v=1765440137"},{"product_id":"bently-nevada-136711-02-3500-61-rtd-tc-i-o-module","title":"Bently Nevada 136711-02 3500\/61 RTD\/TC I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136711-02\u003c\/strong\u003e is a specialized \u003cstrong\u003eRTD\/TC I\/O Module with Internal Barriers and Internal Terminations\u003c\/strong\u003e developed for the \u003cstrong\u003e3500\/61 16-Channel Temperature Monitor\u003c\/strong\u003e within the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. This hardware component serves as the physical interface layer that collects multi-channel temperature signals from field-located transducers. This specific non-isolated variant is engineered with integrated safety barriers, allowing users to configure the termination paths to accept either thermocouple (TC) or resistance temperature detector (RTD) inputs, as well as a flexible combination of both sensor categories simultaneously within the same rack subsystem.\u003c\/p\u003e\n\u003cp\u003eField programming and configuration of channel types are handled through the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e, removing any requirements for physical hardware modifications or field calibration procedures. The module conditions the raw millivolt signals from thermocouples and resistance variances from 3-wire or 4-wire RTDs, feeding structured digital temperature values directly into the main front processor card via the internal backplane bus. Its onboard intrinsic safety design provides a high degree of integration by combining terminal blocks and hazardous area containment barriers into a single space-saving footprint, making the \u003cstrong\u003e3500\/61\u003c\/strong\u003e subsystem ideal for multi-point thermal surveillance of bearings, stator windings, and exhaust paths on heavy rotating assets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHouses physical internal termination blocks paired with integrated safety barriers for hazardous field environments.\u003c\/li\u003e\n\u003cli\u003eNon-isolated universal channel paths support individual configuration for TCs, 3-wire RTDs, or 4-wire RTDs.\u003c\/li\u003e\n\u003cli\u003eEliminates the need for manual component calibration through full integration with the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes dedicated high-precision current source networks to satisfy multi-lead RTD measuring circuits.\u003c\/li\u003e\n\u003cli\u003eStructural design optimizes rack footprint by consolidating external terminal boxes and separate intrinsic safety hardware into one rear slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-channel motor and generator stator winding thermal monitoring.\u003c\/li\u003e\n\u003cli\u003eGas turbine exhaust gas temperature (EGT) profile tracking and distribution mapping.\u003c\/li\u003e\n\u003cli\u003eIndustrial bearing temperature monitoring on high-speed pumps, fans, and gearboxes.\u003c\/li\u003e\n\u003cli\u003eBalance-of-plant auxiliary machinery protection across chemical and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e136711-02: RTD\/TC I\/O Module with Internal Barriers and Internal Terminations (Non-Isolated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical \u0026amp; Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Subtype\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated with Internal Safety Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Current Source Value\u003c\/td\u003e\n\u003ctd\u003e925 +\/- 15 uA at 25 degC per transducer (1 supply for 4-wire RTD, 2 supplies for 3-wire RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer \u0026amp; Sensor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple (TC) Capability\u003c\/td\u003e\n\u003ctd\u003eType E, Type J, Type K, Type T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Temperature Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eType E: -100 degC to +1000 degC (-148 degF to +1832 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType J: -18 degC to +760 degC (+0 degF to +1400 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType K: -18 degC to +1370 degC (+0 degF to +2498 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType T: -160 degC to +400 degC (-256 degF to +752 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Temperature Detector (RTD)\u003c\/td\u003e\n\u003ctd\u003e100 Ohm platinum (alpha = 0.00385), 100 Ohm platinum (alpha = 0.00392), 120 Ohm nickel, 10 Ohm copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Measurement Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm platinum (0.00385): -200 degC to +850 degC (-328 degF to +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e100 Ohm platinum (0.00392): -200 degC to +700 degC (-328 degF to +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e120 Ohm nickel: -80 degC to +260 degC (-112 degF to +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e10 Ohm copper: -100 degC to +260 degC (-148 degF to +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges with External Barriers\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm platinum (0.00385): -50 degC to +850 degC (-122 degF to +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e100 Ohm platinum (0.00392): -50 degC to +260 degC (-122 degF to +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e120 Ohm nickel: -50 degC to +260 degC (-122 degF to +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e10 Ohm copper: -50 degC to +260 degC (-122 degF to +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Conditioning \u0026amp; Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF (except for 10 Ohm Copper RTDs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Isolated External Termination Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBulkhead Rack: +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eStandard Rack: +\/-1 degC at 25 degC (+\/-1.8 degF at 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolated Internal Termination Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBulkhead Rack: +\/-2 degC at 25 degC (+\/-3.6 degF at 77 degF) \/ +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eStandard Rack: +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eNo field calibration required; specified at +25 degC (+77 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (32 degF to +150 degF) when used with Internal Barrier modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Dimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Position Requirements\u003c\/td\u003e\n\u003ctd\u003eConsumes 1 full-height rear slot directly behind the main monitor processor card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Barrier Screw Terminals\u003c\/td\u003e\n\u003ctd\u003eDirect physical land connection for raw multi-wire RTD leads and TC field extensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Backplane Bus Plug\u003c\/td\u003e\n\u003ctd\u003eMulti-pin interconnect matrix delivering conditioned sensor data to the 3500 rack bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Install the \u003cstrong\u003e136711-02\u003c\/strong\u003e module directly from the rear side of the 3500 monitoring chassis. It must align perfectly into the slot corresponding to the front-mounted 3500\/61 main processor card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type Matching:\u003c\/strong\u003e Verify through configuration utility software that each channel configuration (thermocouple versus 3-wire or 4-wire RTD) exactly matches the field wire layout connected to the terminal strip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Wire Uniformity:\u003c\/strong\u003e For all 3-wire and 4-wire RTD configurations, employ copper lead wires of uniform gauge and length to guarantee precise lead-resistance compensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Control:\u003c\/strong\u003e Run all external field sensor lines through twisted, shielded wire pairs. Land the shields at the designated instrumentation ground terminal provided on the module frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enforcement:\u003c\/strong\u003e Ensure the cabinet installation maintains clean, unobstructed ventilation paths so that the active operating ambient temperature around the internal barrier housing does not exceed 65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 136711-02 component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as the rear terminal and intrinsic safety interface module that routes field RTD and thermocouple signals into a 3500\/61 monitor slot.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the designation non-isolated mean for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt indicates that the channels share a common ground reference point, although they remain protected via built-in internal safety barriers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix thermocouples and RTDs on the same I\/O card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the non-isolated channel paths can be customized individually via software to accept a mixed combination of TCs and RTDs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific type of RTD is recommended for standard engineering installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlatinum RTDs featuring an alpha value of 0.00385 are the industrial standard and are highly recommended for optimal precision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs manual field calibration required after replacing this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo manual field calibration is needed because all channel parameter scaling is managed automatically through system configuration software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat constant current value is provided for RTD sensors by this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated current source network delivers 925 +\/- 15 uA at an environmental reference of 25 degC per transducer pathway.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many internal current supplies are engaged when a 4-wire RTD is connected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module configuration activates a single current supply line for a 4-wire RTD circuit and two separate supplies for a 3-wire RTD circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the defined operating temperature limitation for this module version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is specified to perform reliably in a continuous ambient temperature environment ranging from 0 degC to +65 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the exact physical dimensions of this rear-mount component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe card measures 241.3 mm in height, 24.4 mm in width, and 163.1 mm in depth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this component contain the primary digital processor card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this part number represents the rear-insert I\/O termination assembly with built-in barriers; the front processor module is supplied separately.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520273259,"sku":"3500\/61 136711-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-136711-02-temperature-module-cnm5uk4ps0a_ea8ec829-abb6-47bf-af49-d0ad661bbb09.jpg?v=1765440149"},{"product_id":"bently-nevada-135473-01-3500-25-keyphasor-i-o-module-internal-barriers","title":"Bently Nevada 135473-01 3500\/25 Keyphasor I\/O Module (Internal Barriers)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized half-height I\/O module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced Keyphasor system. This specific configuration integrates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInternal Barriers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInternal Terminations\u003c\/strong\u003e, providing a hardware-based intrinsic safety interface for transducers located in hazardous areas. The module is engineered to receive and process once-per-turn or multiple-per-turn pulse signals from proximity probes or magnetic pickups, which are essential for calculating machine rotative speed and providing a phase reference for vibration analysis.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the physical interface within the 3500 rack, ensuring electrical isolation and signal conditioning for critical machinery protection. While the module supports phase measurements, it is optimized for high-accuracy shaft speed monitoring. When utilizing the internal barrier version, the module provides a secure connection point that limits electrical energy dispatched to field sensors, complying with rigorous industrial safety standards for explosive atmospheres.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKeyphasor I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Barriers (Zener Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Transducer Signals (Proximity or Magnetic Pickup)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.2 Watts typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.8 k ohm minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range (Non-Isolated)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+0.8 V to -21.0 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMagnetic Pickup Min Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 200 rpm (3.3 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 103.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 kg (1.01 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C to +65 deg C (32 deg F to +150 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +85 deg C (-40 deg F to +185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eIndustrial procurement should focus on the specific part number to ensure compatibility with the 3500\/25 monitor configuration.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Keyphasor I\/O Module with Internal Barriers and Internal Terminations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: Original New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAvailability\u003c\/strong\u003e: Spare Part Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module provide isolation for Proximitor applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is compatible with Proximitor applications but requires an external power supply to provide isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary design intent of the Isolated I\/O version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt was created specifically for magnetic pickup applications where signals are tied in parallel to multiple devices, such as control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if input signals exceed the specified range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSignals exceeding the specified voltage range are limited internally by the module circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Reference: Wiring, Jumpers, and Specifications\u003c\/h3\u003e\n\u003ch3\u003e1. CHANNEL WIRING \u0026amp; PIN DEFINITIONS\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an Internal Termination I\/O module with built-in Galvanic Barriers. It features two independent terminal strips for Channel 1 and Channel 2.\u003c\/p\u003e\n\u003ch4\u003eA. Proximity Probe Wiring (3-Wire)\u003c\/h4\u003e\n\u003cp\u003eFor standard eddy current sensors (e.g., 3300 XL series):\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR (-24V):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower output for the Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM (GND):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSignal common\/return.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG (OUT):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInput for the pulse voltage signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Magnetic Pickup Wiring (Passive 2-Wire)\u003c\/h4\u003e\n\u003cp\u003eFor self-generating electromagnetic speed sensors:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect to sensor positive (+) lead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect to sensor negative (-) lead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMust remain disconnected (Floating).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Shielding and IS Grounding\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSHLD (Shield):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect field cable shields to this dedicated terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIS Earth :\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module must be grounded via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01 Barrier Earth Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto a dedicated Intrinsic Safety ground bus to ensure explosion-proof integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. HARDWARE JUMPER CONFIGURATIONS\u003c\/h3\u003e\n\u003cp\u003eJumpers are located on the internal circuit board and must be set before installation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Jumper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Coupling Jumper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLogical Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProximity Probe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eINT\u003c\/strong\u003e (Internal)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC\u003c\/strong\u003e (Direct Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides power; allows DC bias.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMagnetic Pickup\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEXT\u003c\/strong\u003e (External\/OFF)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC\u003c\/strong\u003e (Alternating Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCuts power; filters DC noise.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eIMPORTANT:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways power down the 3500 rack or remove the Monitor Module before adjusting jumpers to avoid electrical arcing.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr\u003e\n\u003ch3\u003e3. CORE PERFORMANCE SPECIFICATIONS\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 independent input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 to 1,200,000 cpm (\u003cstrong\u003e0.017 Hz to 20 kHz\u003c\/strong\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e+5V to -11V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(specifically for Barrier I\/O).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConditioning Modes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Threshold:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMin signal 2 V peak-to-peak; min speed 120 rpm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManual Threshold:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjustable from 0 to -20 Vdc; min signal 500 mV; supports low speed down to 1 rpm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3.2 Watts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Typical).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 deg C to 65 deg C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. HAZARDOUS AREA CERTIFICATIONS\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-risk environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNorth America:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass I, Div 2, Groups A, B, C, D.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEurope (ATEX):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eII 1 G [EEx ia] IIC (Inputs rated for Zone 0).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e5. SYSTEM CONFIGURATION SUPPORT\u003c\/h3\u003e\n\u003cp\u003eAfter the physical installation, use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto verify:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHysteresis Settings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent false triggering on noisy signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrientation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSetting the pulse direction (Positive\/Negative).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsuring the software matches the physical jumper settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003ePART 2: TERMINAL DIAGRAMS \u0026amp; SOFTWARE CONFIGURATION\u003c\/h3\u003e\n\u003ch3\u003e1. TERMINAL BLOCK PINOUT (A\/B\/C\/D)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses a specific 4-terminal sequence for each channel. Below is the mapping for connecting your field wiring:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLabel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProximity Probe (3-Wire)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMagnetic Pickup (2-Wire)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePWR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 Vdc Power (White)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNO CONNECTION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommon\/GND (Black)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Negative (-)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Input (Red)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Positive (+)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSHLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShield\/Drain Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShield\/Drain Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e2. SOFTWARE CONFIGURATION (3500 RACK CONFIG)\u003c\/h3\u003e\n\u003cp\u003eOnce the hardware is installed, you must configure the following in the software utility:\u003c\/p\u003e\n\u003ch4\u003eA. Threshold Settings\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Threshold\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe system automatically calculates the trigger point at 50% of the signal amplitude.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e: Standard operating speeds (\u0026gt;120 rpm) with clean, consistent pulses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManual Threshold\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYou manually set a fixed voltage (e.g., -8.0 Vdc).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e: Low-speed start-ups or signals with significant \"glitch\" or noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCalculation Tip\u003c\/strong\u003e: Set the threshold to the midpoint between the pulse peak and the baseline signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Hysteresis (Noise Reduction)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMagnetic Pickups\u003c\/strong\u003e, you should set a Hysteresis value (typically\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.2V to 0.5V\u003c\/strong\u003e) to prevent the monitor from \"double-triggering\" if the signal is noisy as it crosses the threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Active Edge (Direction)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNegative Edge\u003c\/strong\u003e: Triggers as the signal goes from 0V toward -24V (Standard for most Bently probes).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePositive Edge\u003c\/strong\u003e: Triggers as the signal moves in a positive direction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e3. CRITICAL INSTALLATION CHECKLIST\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBarrier Earth\u003c\/strong\u003e: Ensure the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is installed in the rack. Without this, the 135473-01 cannot properly ground the internal safety barriers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper Audit\u003c\/strong\u003e: Double-check that\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eChannel 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ejumpers match their respective sensors. A common error is leaving the PWR jumper on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhen using a Magnetic Pickup, which can induce noise or heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEncoding\u003c\/strong\u003e: Use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeg C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCelsius\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein your technical documentation to avoid the corrupted character issues previously encountered in your CMS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847134059,"sku":"135473-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135473-01-motion-controller-module-with-316l-stainless-steel-case-material-ag55zssqu3e_fe8b3db7-fd2e-41ca-ad85-8851d4d47e88.jpg?v=1765448946"},{"product_id":"bently-nevada-3500-61-02-00-133827-02-temperature-monitor-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 3500\/61-02-00 133827-02 Temperature Monitor RTD\/TC Non-Isolated I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/61-02-00\u003c\/strong\u003e is a six-channel temperature monitoring module designed for the \u003cstrong\u003eBently Nevada 3500 Machinery Protection System\u003c\/strong\u003e. The module accepts both RTD and thermocouple temperature inputs and performs continuous temperature measurement and alarm comparison functions for critical rotating machinery applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e133827-02\u003c\/strong\u003e RTD\/TC Non-Isolated I\/O Module uses external terminations and supports mixed RTD and TC input configurations. Users can configure individual channels through the 3500 Rack Configuration Software for RTD or thermocouple operation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/61\u003c\/strong\u003e series differs from the \u003cstrong\u003e3500\/60\u003c\/strong\u003e by providing recorder outputs for each monitoring channel. Recorder outputs support 4 to 20 mA transmission proportional to the configured monitor full-scale range.\u003c\/p\u003e\n\u003cp\u003eThe module supports up to six transducer inputs and provides programmable Alert and Danger alarm setpoints. In Triple Modular Redundant (TMR) systems, temperature monitors install adjacent in groups of three to support redundant voting logic and fault tolerance.\u003c\/p\u003e\n\u003cp\u003eThe module is suitable for turbine monitoring systems, compressor trains, process plants, power generation facilities, and industrial machinery protection applications requiring temperature supervision and alarm processing.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSix-channel temperature monitoring\u003c\/li\u003e\n\u003cli\u003eSupports RTD and thermocouple inputs\u003c\/li\u003e\n\u003cli\u003eMixed RTD and TC channel configuration supported\u003c\/li\u003e\n\u003cli\u003eExternal termination non-isolated I\/O design\u003c\/li\u003e\n\u003cli\u003eRecorder outputs for all six channels\u003c\/li\u003e\n\u003cli\u003eUser-configurable alarm setpoints\u003c\/li\u003e\n\u003cli\u003eSoftware configurable RTD or TC measurement mode\u003c\/li\u003e\n\u003cli\u003eCompatible with 3500 Rack Configuration Software\u003c\/li\u003e\n\u003cli\u003eSupports TMR system architecture\u003c\/li\u003e\n\u003cli\u003eFront panel OK, TX\/RX, and Bypass LEDs\u003c\/li\u003e\n\u003cli\u003e4 to 20 mA recorder outputs\u003c\/li\u003e\n\u003cli\u003eChannel full-scale configuration through software\u003c\/li\u003e\n\u003cli\u003eNo calibration required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine temperature monitoring\u003c\/li\u003e\n\u003cli\u003eGas turbine protection systems\u003c\/li\u003e\n\u003cli\u003eCompressor temperature supervision\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating machinery monitoring\u003c\/li\u003e\n\u003cli\u003eProcess plant shutdown systems\u003c\/li\u003e\n\u003cli\u003ePower generation equipment protection\u003c\/li\u003e\n\u003cli\u003ePetrochemical process monitoring\u003c\/li\u003e\n\u003cli\u003eLNG facility machinery monitoring\u003c\/li\u003e\n\u003cli\u003eCritical equipment alarm systems\u003c\/li\u003e\n\u003cli\u003eTMR machinery protection installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/61-02-00: Complete RTD\/TC Monitor Kit with External Terminations\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifies the combined kit containing the 3500\/61 main monitor module and the specific non-isolated rear I\/O board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02: I\/O Module Type Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRTD\/TC Non-isolated I\/O Module with External Terminations (Rear Board Part Number: \u003cstrong\u003e133827-02\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Agency Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo hazardous area agency approvals or certifications required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpares \u0026amp; Accessories\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number \u003cstrong\u003e133827-02\u003c\/strong\u003e: Replacement 3500\/61 RTD\/TC Non-Isolated I\/O Module with External Terminations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTemperature Monitor RTD\/TC Non-Isolated I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/61-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Part Number\u003c\/td\u003e\n\u003ctd\u003e133827-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1 to 6 RTD or TC transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 Mohm for each lead input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Compliance\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc across load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd\u003e0 to 600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.3662 uA per bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Current Source\u003c\/td\u003e\n\u003ctd\u003e925 +\/-15 uA at 25 degC per transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Delay Range\u003c\/td\u003e\n\u003ctd\u003eAlert: 1 to 60 s, Danger: 1 to 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Dimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 x 24.4 x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Weight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 x 24.4 x 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Slot Requirement\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot and 1 rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRTD Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Type\u003c\/td\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 ohm Platinum RTD Alpha 0.00385\u003c\/td\u003e\n\u003ctd\u003e-200 degC to +850 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 ohm Platinum RTD Alpha 0.00392\u003c\/td\u003e\n\u003ctd\u003e-200 degC to +700 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 ohm Nickel RTD\u003c\/td\u003e\n\u003ctd\u003e-80 degC to +260 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 ohm Copper RTD\u003c\/td\u003e\n\u003ctd\u003e-100 degC to +260 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eThermocouple Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Type\u003c\/td\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003ctd\u003e-100 degC to +1000 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003ctd\u003e-18 degC to +760 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003ctd\u003e-18 degC to +1370 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003ctd\u003e-160 degC to +400 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Conditioning Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD and TC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper RTD Resolution\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Junction Compensation Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-1 degC at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin 0.13% of desired value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Termination Non-Isolated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-1 degC at 25 degC standard rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBulkhead Rack Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-3 degC at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOutputs and Indicators\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicator or Output\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK LED\u003c\/td\u003e\n\u003ctd\u003eIndicates proper monitor operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX\/RX LED\u003c\/td\u003e\n\u003ctd\u003eIndicates communication with rack modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBypass LED\u003c\/td\u003e\n\u003ctd\u003eIndicates bypass mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003eIndividual 4 to 20 mA outputs per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatinum RTD Selection\u003c\/strong\u003e: Platinum RTDs with a 0.00385 alpha coefficient conform to global industrial standards and are recommended for all new temperature loop deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder Short-Circuit Immunity\u003c\/strong\u003e: Internal circuitry ensures that the core machinery monitoring and alarm logic remain unaffected by short circuits on external recorder loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnder and Over Setpoints\u003c\/strong\u003e: The internal processing engine provides both upper and lower alarm bounds for multi-directional protection (e.g., cryogenic or overheating states).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTMR Requirements\u003c\/strong\u003e: When configured for Triple Modular Redundancy, three identical temperature monitors must reside in consecutive, adjacent front-chassis slots.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Termination Wiring\u003c\/strong\u003e: Route all RTD or TC lead wires to the external termination block ensuring clean, gas-tight connections to maintain CJC accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Terminate the cable shields exclusively at the designated shield grounding terminal on the I\/O module to prevent ground loops and shield against electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJC Sensor Matching\u003c\/strong\u003e: Ensure the Cold Junction Compensation sensor is securely mounted to the terminal base for accurate ambient compensation during thermocouple measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Resistance Minimization\u003c\/strong\u003e: For 3-wire and 4-wire RTD hookups, keep lead wire lengths identical to balance line-drop and ensure accurate bridge compensation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between the 3500\/60 and the 3500\/61 modules?\u003c\/strong\u003e A: Both modules provide identical temperature monitoring and alarm logic, but the 3500\/61 features six independent +4 to +20 mA individual recorder outputs whereas the 3500\/60 does not.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this specific non-isolated I\/O module option provide channel-to-channel isolation?\u003c\/strong\u003e A: No, this is the 02 option which is non-isolated; if channel-to-channel isolation is needed to counteract heavy ground faults or high-voltage line crossovers, the isolated I\/O module version should be specified instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is field calibration required for the 3500\/61 module upon installation?\u003c\/strong\u003e A: No field calibration is required as full-scale ranges and sensor types are configured digitally using the 3500 Rack Configuration Software.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847691115,"sku":"3500\/61-02-00 133827-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-02-00-133827-02-rtd-tc-temperature-i-o-module-tul1fywpxs1_6cd7fe54-1ece-464e-8d43-bdb06cb565fb.jpg?v=1765448969"},{"product_id":"bently-nevada-3500-33-04-00-149992-04-low-current-16-channel-failsafe-relay-output-module","title":"Bently Nevada 3500\/33-04-00 149992-04 Low Current 16-Channel Failsafe Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/33-04-00 149992-04\u003c\/strong\u003e is a \u003cstrong\u003e16-channel failsafe relay output module\u003c\/strong\u003e used as a main or spare module in \u003cstrong\u003e3500 machinery protection systems\u003c\/strong\u003e. It provides 16 independently programmable relay outputs with alarm drive logic, supporting AND\/OR logic combinations of alert, danger, Not-OK statuses, and measured variables from any monitor channel. Each relay output can perform voting logic and integrates with the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module interfaces with \u003cstrong\u003ePLC, DCS, SIS, and TSI systems\u003c\/strong\u003e, offering both normally de-energized (ND) and normally energized (NE) operation selectable in four groups of four channels. Front-panel LEDs indicate module status, communication activity, and channel alarm states.\u003c\/p\u003e\n\u003cp\u003eIt supports low current switching applications with gold-plated contacts, suitable for standard, failsafe, or hazardous area configurations. Module compatibility includes installation to the right of the Transient Data Interface (TDI) in a \u003cstrong\u003e3500 rack\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 relay outputs with independent programmable logic\u003c\/li\u003e\n\u003cli\u003eAlarm drive logic using AND\/OR conditions\u003c\/li\u003e\n\u003cli\u003eSelectable normally de-energized (ND) or normally energized (NE) operation\u003c\/li\u003e\n\u003cli\u003eFront-panel LEDs for OK, TX\/RX, and channel alarm status\u003c\/li\u003e\n\u003cli\u003eEpoxy-sealed relays with arc suppressors (250 Vrms)\u003c\/li\u003e\n\u003cli\u003eRelay life up to 10,000 cycles\u003c\/li\u003e\n\u003cli\u003eLow current gold-plated contact option for 1 mA @ 1 Vdc minimum load\u003c\/li\u003e\n\u003cli\u003eCompatible with 3500 Rack Configuration Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial machinery monitoring and protection\u003c\/li\u003e\n\u003cli\u003eProcess automation alarm outputs\u003c\/li\u003e\n\u003cli\u003eHazardous area relay interfacing\u003c\/li\u003e\n\u003cli\u003eIntegration with PLC, DCS, SIS, TSI systems\u003c\/li\u003e\n\u003cli\u003eLow-current signal switching in control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/33-04-00: Complete 16-Channel Relay Module Assembly\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifies the pre-configured combination consisting of the front main module card and the rear low-current failsafe output board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04: Output Module Type Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLow Current 16-Channel Failsafe Relay Output Module featuring gold-plated contacts (Rear I\/O Module Spare: \u003cstrong\u003e149992-04\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Hazardous Area Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo hazardous area agency approvals or certifications required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpares \u0026amp; Accessories\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number \u003cstrong\u003e149992-04\u003c\/strong\u003e: Spare 16-Channel Low Current Failsafe Relay Output Module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMain module: 0.7 kg (1.6 lb), I\/O module: 0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMain module: 241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in), I\/O module: 241 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space\u003c\/td\u003e\n\u003ctd\u003eMain: 1 full-height front slot, I\/O: 1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSPDT (Single-pole Double-throw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Arc Suppressor\u003c\/td\u003e\n\u003ctd\u003e250 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003eStandard: 100 mA @ 5 Vdc, Low Current: 1 mA @ 1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003eDC: 5 A, AC: 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Power\u003c\/td\u003e\n\u003ctd\u003eDC: 70 W @ 24 Vdc, AC: 1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003eDC: 125 Vdc, AC: 250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eOK, TX\/RX, CH Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/D-Agent_1-_work-77-s-Upload-162096J1.pdf?v=1780026391\"\u003eRefer to 3500 rack manual\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay outputs, power, communication connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eGrounding and Shielding\u003c\/h4\u003e\n\u003cp\u003eEnsure the rack frame is properly tied to the plant instrumentation ground before inserting modules. Field wiring shields should be terminated at the designated shield terminals on the I\/O module to minimize electromagnetic interference and ensure signal integrity.\u003c\/p\u003e\n\u003ch4\u003eHazardous Area Precautions\u003c\/h4\u003e\n\u003cp\u003eDo not disconnect field wiring or module connections while the circuit is live unless the location is verified to be non-hazardous. Live handling in explosive atmospheres can result in arc-induced ignition risks.\u003c\/p\u003e\n\u003ch4\u003eModule Placement\u003c\/h4\u003e\n\u003cp\u003eAlign the main module with the chosen front slot to the right of the TDI module. Slide it firmly into the backplane connectors and tighten the panel screws. Install the matching I\/O module in the corresponding slot directly on the rear of the rack assembly.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 04 option signify in this module part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e The 04 code specifies that this is the Low Current 16-Channel Failsafe variant equipped with gold-plated contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum current rating for the gold-plated contact version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe minimum switched current rating is 1 mA @ 1 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix the configuration for Normally Energized and Normally De-energized modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the sixteen channels are split into four distinct groups of four channels, and each group is independently switch-selectable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the TX\/RX LED on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TX\/RX LED flashes to indicate active transmission and reception of communication data between this module and other rack modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware package contain built-in spark protection for the contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, an internal 250 Vrms epoxy-sealed relay arc suppressor is standard equipment on the hardware channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit process individual variables from multiple monitor modules at once?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the Alarm Drive Logic can combine Alert, Danger, or Not-OK inputs from any monitor channel or combination of monitor channels within the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software tool is required to configure the voting logic pathways?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system logic is engineered and uploaded using the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the relay operation if the module encounters an internal failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Failsafe design ensures that when a major failure or loss of control occurs, the relays drop to their safe de-energized or default state depending on wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to exceed 5 mA when using an AC supply voltage up to 120Vac?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, currents exceeding 5 mA on these low-current gold relays will degrade or permanently damage the contact plating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many slots does the complete main and I\/O assembly take up?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt occupies one full-height slot on the front of the rack and one corresponding full-height slot on the rear panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I plug this module into the slot immediately adjacent to the power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt must be placed in any available slot situated to the right of the Transient Data Interface module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a solid light on the OK LED indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA solid light confirms that the hardware is powered up, has passed initial self-tests, and is operating properly.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848837995,"sku":"3500\/33-04-00 149992-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-04-00-149992-04-relay-i-o-module-fkulr4tcehu_c36c9898-9ec7-4d81-a6b1-b3299e531e38.jpg?v=1765448997"},{"product_id":"bently-nevada-3500-15-04-04-01-133300-01-legacy-low-voltage-dc-power-input-module","title":"Bently Nevada 3500\/15-04-04-01 133300-01 Legacy Low Voltage DC Power Input Module","description":"\u003cp style=\"color: #2d3748;\"\u003eThe \u003cstrong\u003eBently Nevada 3500\/15-04-04-01\u003c\/strong\u003e, operating in absolute conjunction with the \u003cstrong\u003e133300-01\u003c\/strong\u003e rear interface, is an industrial-grade half-height rack power conversion engine designed for the 3500 Series Machinery Protection System. This specific hardware combination forms a legacy low-voltage direct current input infrastructure, receiving raw plant supply vectors and executing high-isolation step-down regulation to feed the internal passive backplane rails with tightly monitored DC operating potentials.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTrue N+1 Redundant Topology:\u003c\/strong\u003e Supports continuous dual-supply allocation within a single rack configuration where the lower bay functions as the primary power source and the upper bay serves as an un-interrupted hot-standby unit.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eZero-Downtime Hot Swappability:\u003c\/strong\u003e Internal dynamic balancing circuits permit the physical removal or insertion of either power card while the machinery monitor rack remains fully energized, preventing false trips or protection blind spots.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eGalvanic Isolation Barrier:\u003c\/strong\u003e Designed with heavily separated circuitry paths between input terminals and backplane connections to absorb massive field-side voltage transients and ground-loop fluctuations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Input Module (PIM):\u003c\/strong\u003e Paired with the legacy 133300-01 rear module featuring robust terminal blocks and optimized input filter footprints dedicated to low-voltage battery banks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eCritical Turbomachinery Protection:\u003c\/strong\u003e Delivers stable operational rails for critical shaft vibration, thrust position, and speed monitoring modules across steam and gas turbine trains.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePlant Battery Bank Integration:\u003c\/strong\u003e Direct connection to central industrial 24V DC battery backup systems inside power generation and petrochemical processing facilities.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Availability Control Cabinets:\u003c\/strong\u003e Deployment in remote machine enclosures demanding maximum system uptime via redundant instrumentation power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eOption Code\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eEngineering Selection Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003e3500\/15-AA-BB-CC Base Configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eAA - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLegacy Low Voltage DC Power Supply (20 to 30 Vdc range)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eBB - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLegacy Low Voltage DC Power Input Module (PIM)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eCC - 01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAgency Approval Option: CSA-c-US (Class I, Division 2, Groups A, B, C, D)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003eComponent Breakdown Part Numbers\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; padding-left: 20px;\"\u003e106M1081-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLegacy Low Voltage DC Power Supply Main Card Assembly\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; padding-left: 20px;\"\u003e133300-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLegacy Low Voltage DC Power Input Module (PIM) Rear Hardware\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eTechnical Parameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eVerified Engineering Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e20 Vdc to 30 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaximum Input Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10.0 A continuous\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTypical Power Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e230 Watts maximum under full chassis load configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Regulated Rails\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e+5 Vdc, -5 Vdc, +15 Vdc, -15 Vdc distributed via passive backplane\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDielectric Isolation Strength\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e500 Vdc terminal-to-chassis ground resistance rating\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eForm Factor Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHalf-height card layout (Occupies specific left-side rack slots)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 Celsius to +65 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 Celsius to +85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRelative Humidity Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUp to 95% relative humidity, non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFront Panel Status Monitoring\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIntegrated green 'Supply OK' LED diode matrix\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMain Supply Card Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.77 kg (1.70 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRear Input PIM Card Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.31 kg (0.68 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTotal System Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.08 kg (2.38 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.55 kg (Complete double-card boxed system)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e285 mm x 210 mm x 155 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eTerminal Designation\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eCircuit Interface Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDC+\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePositive DC Input Line (Accepts +20 to +30 Vdc reference)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDC-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNegative DC Return Line (Power circuit common return path)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eGND\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSafety Earth Ground Connection (Direct metal frame path link)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Isolate the primary 24V DC upstream supply loop breaker before starting installation. Do not manipulate or wire live power lines directly to the 133300-01 rear compression block. Bridging live lines risks continuous arc flash generation, internal short circuits across the copper layers, and permanent failure of all monitoring cards on the common backplane.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect a verified anti-static grounding wrist strap to the unpainted rack frame to discharge potential personal static build-up before opening module protection envelopes.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePush the main half-height power card smoothly down its dedicated slot runners on the front left side of the 3500 chassis until it mates with the backplane pin assembly.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the legacy 133300-01 power input card into the parallel rear bay position. Fully tighten the rear retaining screws to secure the unit against persistent mechanical vibrations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eStrip field feeder cables back by 7 millimeters, insert them firmly into the DC terminal clamp block matching the verified polarities, and torque the clamping screws down to specification.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850673003,"sku":"3500\/15-04-04-01 133300-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-04-04-01-133300-01-low-voltage-dc-power-input-module-jkcdk13hega_bc249377-abc5-4e7b-890f-e8d2efa9342f.jpg?v=1765449036"},{"product_id":"bently-nevada-3300-30-six-channel-temperature-tc-input-monitor","title":"Bently Nevada 3300\/30 Six-Channel Temperature TC Input Monitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/30 Six-Channel Temperature Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a six-channel temperature monitoring module designed for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e.\u003cbr\u003eThis version is specifically configured to accept\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThermocouple (TC) inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erather than RTD sensors.\u003c\/p\u003e\n\u003cp\u003eIt is commonly used to monitor critical temperature points in industrial machinery, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBearing metal temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExhaust gas temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStator winding temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLube oil system temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe monitor provides continuous protection through configurable alarm relays and standard recorder outputs, ensuring reliable thermal supervision in turbine, compressor, and generator applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003e1. Inputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esix (6) independent thermocouple inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEach channel operates independently\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Thermocouple Types\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Iron \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Alumel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Copper \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInternal compensation provided at the terminal block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatically corrects measurement drift caused by ambient temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures stable temperature accuracy across operating environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWithin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±2.2% of signal\u003c\/strong\u003e, plus thermocouple tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReference temperature:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOpen Thermocouple Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor includes automatic fault detection when a thermocouple circuit opens.\u003c\/p\u003e\n\u003cp\u003eSelectable response modes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to high value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDownscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to low value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis feature prevents machinery from operating without temperature protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAll six channels scanned approximately:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.5 seconds per cycle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis scan speed is typical for machinery protection systems where temperature changes occur gradually compared to vibration signals.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Outputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUser-programmable analog outputs:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 to +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to -10 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 to +5 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvailable for diagnostic and monitoring purposes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel coaxial connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRear terminal block connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne buffered output per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese outputs are typically connected to:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDCS systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData recorders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. Alarms \u0026amp; Display\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e7-segment LCD temperature display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShows real-time temperature value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChannel selection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebutton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCycles through Channel 1 to Channel 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach channel supports independent alarm configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlert alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDanger alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth thresholds are fully adjustable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOK Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinuously monitors system health, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/30-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003chr\u003e\n\u003ch3\u003eA — Full-Scale Range Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eTemperature Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0 to 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0 to 500°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0 to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e32 to 212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e32 to 392°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e32 to 932°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003e32 to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — Thermocouple Input Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eThermocouple Type\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — Alarm Relay Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — Agency Approval Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCertification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX self-certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — Safety Barrier Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eExternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eInternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eSpace Requirement\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/30 temperature monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDouble-width module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation requirement:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOccupies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo (2) slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the 3300 rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is important when planning rack capacity in retrofit or expansion projects.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThermocouple Lead Wire Requirement\u003c\/h3\u003e\n\u003cp\u003eAlways use the correct\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouple extension wire\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat matches the thermocouple type.\u003c\/p\u003e\n\u003cp\u003eExamples:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType K → Type K extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType J → Type J extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing standard copper wire will introduce:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eJunction voltage errors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement drift\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration inaccuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is one of the most common field installation mistakes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGrounding Practice\u003c\/h3\u003e\n\u003cp\u003eRecommended grounding method:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround the thermocouple shield at the monitor rack only\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvoid grounding at multiple points.\u003c\/p\u003e\n\u003cp\u003eImproper grounding can cause:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGround loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnstable temperature readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpecial attention is required when using:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounded-tip thermocouples\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese sensors are more sensitive to grounding configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCold Junction Environment Control\u003c\/h3\u003e\n\u003cp\u003eDo not install the monitor rack in locations with:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRapid temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong airflow across terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh thermal gradients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese conditions can affect the accuracy of the internal cold junction compensation.\u003c\/p\u003e\n\u003cp\u003eTypical problematic locations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNear ventilation ducts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClose to turbine exhaust paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutdoor panels without thermal shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850935147,"sku":"3300\/30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-30-position-monitor-module-aahygilvquw_7ed0cd2c-10d0-4b8c-b33c-9c8d65d61045.jpg?v=1765449041"},{"product_id":"bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbus-i-o-module","title":"Bently Nevada 3500\/92-03-01-00 136188-01 Ethernet\/RS232 Modbus I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/92-03-01-00\u003c\/strong\u003e is a \u003cstrong\u003eCommunication Gateway Module\u003c\/strong\u003e designed for the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. Its primary purpose is to provide continuous, high-speed communication capability for all rack-monitored values and statuses, enabling seamless integration with distributed control systems (DCS), programmable logic controllers (PLC), human-machine interfaces (HMI), and other plant automation systems.\u003c\/p\u003e\n\u003cp\u003eThe module features comprehensive communication interfaces, utilizing both Ethernet TCP\/IP and serial channels (RS232) via the \u003cstrong\u003e136188-01 I\/O module\u003c\/strong\u003e. It handles internal data collection by pulling current measured values, time stamps, module statuses, and alarm statuses from other monitor modules within the rack via a high-speed internal network. Additionally, the \u003cstrong\u003e3500\/92\u003c\/strong\u003e supports direct Ethernet communication with proprietary \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e and \u003cstrong\u003eData Acquisition Software\u003c\/strong\u003e. This specific variant features a Configurable Modbus Register Utility to map system data efficiently into host automation networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous collection of rack data, including current measured values with time stamps, module statuses, and alarm statuses.\u003c\/li\u003e\n\u003cli\u003eSimultaneous communication capability over Ethernet TCP\/IP and serial links.\u003c\/li\u003e\n\u003cli\u003eConfigurable Modbus Register Utility to customize register mapping for host systems.\u003c\/li\u003e\n\u003cli\u003eHigh-speed internal network collection rate that updates all rack modules in less than 1 second.\u003c\/li\u003e\n\u003cli\u003eFront panel LED indicators for immediate monitoring of module operational status (OK) and communication activity (TX\/RX).\u003c\/li\u003e\n\u003cli\u003eBackward compatibility with software features of the original 3500\/90 module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration and status monitoring integration.\u003c\/li\u003e\n\u003cli\u003eCompressor and pump protection data transmission to plant DCS.\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery condition monitoring and predictive maintenance networks.\u003c\/li\u003e\n\u003cli\u003ePower generation and petrochemical plant automation synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3500\/92: Communication Gateway\u003c\/li\u003e\n\u003cli\u003e03: Ethernet\/RS232 Modbus I\/O Module\u003c\/li\u003e\n\u003cli\u003e01: Low Memory\u003c\/li\u003e\n\u003cli\u003e00: None Agency Approval Option\u003c\/li\u003e\n\u003cli\u003e136188-01: Ethernet\/RS232 Modbus I\/O Module Spare (Includes Firmware Upgrade Kit 126M4118-01)\u003c\/li\u003e\n\u003cli\u003e126M4118-01: Firmware Upgrade Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e5.0 Watts typical with Modbus RS232\/RS422 I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eData Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCurrent measured values with time stamp, module statuses, current alarm statuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eUpdate Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eLess than 1 second for all modules in the 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eOK LED Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndicates when the 3500\/92 is operating properly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eTX\/RX LED Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eIndicates when the 3500\/92 is communicating with other modules in the 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eBNC Host Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eEthernet TCP\/IP connection to 3500 Configuration and Data Acquisition Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eModbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eBased on AEG Modicon PI-MBUS-300 Reference Manual, Remote Terminal Unit (RTU) transmission mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eEthernet Link Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e10 Mbps, conforms to IEEE 802.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eEthernet Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eEthernet TCP\/IP frame and Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eEthernet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eRJ-45 for 10BASE-T Ethernet cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-30 degC to +65 degC (-22 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eMain Board Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003cstrong\u003eMain Board Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e0.82 kg (1.8 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e0.44 kg (0.96 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003e\u003cstrong\u003eTotal Assembly Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e1.26 kg (2.76 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eRJ-45 Jack\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e10BASE-T Ethernet TCP\/IP and Modbus\/TCP Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eSerial Port (RS232)\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eModicon Modbus RTU Serial Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Verification:\u003c\/strong\u003e Ensure that older Communication Gateway main modules are upgraded using Firmware Upgrade Kit 126M4118-01 before installing the new 136188-01 I\/O module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Insertion:\u003c\/strong\u003e Insert the main board into the designated communication slot of the 3500 rack, ensuring full seating and secure fastening of the chassis screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Module Alignment:\u003c\/strong\u003e Install the 136188-01 I\/O module directly behind the main module from the rear of the 3500 rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling Constraints:\u003c\/strong\u003e Use standard 10BASE-T Ethernet cabling with RJ-45 connectors for network setups, limiting cable runs according to IEEE 802.3 metrics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Control:\u003c\/strong\u003e Ensure operating ambient conditions do not exceed 65 degC and that ventilation paths on the 3500 chassis remain unobstructed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 3500\/92 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as a communication gateway, exporting data from a 3500 machinery protection rack to external automation systems like PLCs and DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich interfaces are provided on the 136188-01 I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides an RJ-45 Ethernet connection and an RS232 serial interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat protocols can run over the Ethernet connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports Modbus\/TCP protocol as well as the proprietary Bently Nevada host protocol for software applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module differ from the older 3500\/90 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt removes the fixed primary value Modbus registers and replaces them with a flexible Configurable Modbus Register Utility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long does it take for the module to refresh data from the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe data collection rate varies by configuration but is guaranteed not to exceed 1 second for all modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical power consumption of this specific I\/O setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system typically consumes 5.0 Watts when equipped with the Modbus RS232 I\/O module configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I connect my 3500 Configuration Software through this gateway?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it allows Ethernet communications with the 3500 Rack Configuration and Data Acquisition Software packages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check if the TX\/RX LED is dark?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify that the module is correctly seated and that the internal rack communication bus is active and functioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs a firmware upgrade mandatory when swapping in a new 136188-01 interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOlder main gateway modules require a firmware upgrade using kit 126M4118-01 to properly recognize the new I\/O hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the environmental storage limitations for this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module must be stored within an environment ambient temperature range of -40 degC to +85 degC.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852540779,"sku":"3500\/92-03-01-00 136188-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbusi-o-module-p13m3rotikn_8ccc5100-a46c-4dba-8a08-f4cf661d45b3.jpg?v=1765449087"},{"product_id":"bently-nevada-3500-40m-125680-01-proximitor-i-o-module","title":"Bently Nevada 3500\/40M 125680-01 Proximitor I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-127\"\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e125680-01\u003c\/strong\u003e\u003cspan class=\"citation-127 citation-end-127\"\u003e\u003cspan\u003e \u003c\/span\u003eis a 4-channel Proximitor I\/O Module with Internal Terminations engineered for the 3500 Series Machinery Protection System.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSeated in the rear slot of the 3500 instrumentation rack, this module serves as the direct hardware interface linking external eddy current proximity transducers to the front-facing 3500\/40M Proximitor Monitor module.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-126 citation-end-126\"\u003eThe unit provides stable sensor power excitation, receives raw analog displacement voltages, and channels these conditioned paths into the main processor card to calculate machinery metrics like radial vibration, shaft eccentricity, thrust position, differential expansion, and REBAM.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eArmed with an integrated screw-terminal block, the 125680-01 eliminates the need for separate external termination panels, saving critical footprint space within dense control room cabinets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/40M (Rear Component)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number \/ ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125680-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor I\/O Module (Internal Terminations)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Non-Isolated Proximity Transducer Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Input Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kΩ for Proximitor Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Multi-position Screw Terminal Block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.7 Watts Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3300 XL 8mm, 11mm, and 25mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRadial Vibration, Thrust, Eccentricity, REBAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.4 mm x 241.3 mm x 99.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 kg (0.44 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eTurbomachinery monitoring hardware modifications dictate checking explicit spare part numbers. Procure replacements strictly matching the factory ordering codes below.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMain System Component Suffix:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/40M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Order Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125680-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Core Variant:\u003c\/strong\u003e\u003cspan class=\"citation-125 citation-end-125\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard Full-Height Rear I\/O Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Notes \u0026amp; Field Wiring Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Signal Termination Layout\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal termination block of the 125680-01 handles up to four field proximity sensor arrays. Each signal channel grouping contains three dedicated screw terminals:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVTX \/ Prox (+):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransducer power supply voltage rail (typically -24V DC excitation).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG \/ In (S):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContinuous analog raw gap voltage returned from the Proximitor sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM \/ Gnd (-):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommon instrumentation reference return line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStrip conductor insulation back exactly 7 mm. Use high-grade 3-wire twisted-shielded instrumentation cables (18 AWG to 22 AWG copper) to prevent magnetic induction anomalies from distorting high-frequency signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Shield Grounding Protocols\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTerminate individual outer cable shields at the 3500 chassis frame to prevent EMI\/RFI noise. Shield lines must be bundled and bonded to the unpainted rack frame grounding bar using a wide-surface ground clamp.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNever\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etie the cable shield into the terminal block's signal common (COM) screws; doing so generates ground loops that can mask critical high-amplitude vibrations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLive-Swapping Safety Constraints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500 architecture allows hot-swapping; however, pulling a rear I\/O module immediately cuts excitation power to field sensors, triggering a \"Monitor Fault.\"\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eToggle the rack’s front keylock switch to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-124\"\u003eEnable software channel\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003ebypass flags\u003c\/strong\u003e\u003cspan class=\"citation-124 citation-end-124\"\u003e\u003cspan\u003e \u003c\/span\u003evia the 3500 Rack Configuration Software.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProceed with physical removal to prevent downstream emergency trip relays from activating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between the 125680-01 and external termination modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 125680-01 contains built-in screw terminal arrays on its back faceplate, allowing field wiring to anchor directly to the module. External termination variants require high-density multi-pin ribbon cables to connect to a separate DIN-rail terminal panel mounted elsewhere.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 125680-01 module accept signals from non-Bently Nevada proximity sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Internal pathways and scaling matrices are calibrated specifically for Bently Nevada proximity transducers. Third-party probes will break linear scale factors, invalidating measurement conversions and generating calibration errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do you troubleshoot an individual channel showing a persistent \"NOT OK\" status?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Measure the raw DC gap voltage across the SIG and COM terminals with a multimeter. A healthy probe displays between -4V DC and -16V DC. If the voltage is near 0V or mirrors the full -24V supply, the fault is likely a cable short or open conductor in the field rather than an I\/O module failure.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666859290987,"sku":"125680-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125680-01-proximitor-i-o-module-nch0io30ar2_8104b65d-e1e6-431e-b4e2-7a9ec8d0e125.jpg?v=1765449252"},{"product_id":"bently-nevada-81544-01-3300-transducer-input-output-and-recorder-terminal-module","title":"Bently Nevada 81544-01 3300 Transducer Input\/Output and Recorder Terminal Module","description":"\u003cp\u003eThe \u003cstrong\u003e81544-01\u003c\/strong\u003e Transducer Input\/Output and Recorder Terminal Module, alternative factory part number \u003cstrong\u003e78462-02\u003c\/strong\u003e, is a rear-mounting interface component engineered exclusively for the Bently Nevada 3300\/45 Dual Differential Expansion Monitor within a Turbine Supervisory Instrumentation system. The module facilitates the dual-channel routing of dynamic signal inputs from two separate proximity probe transducer setups to evaluate absolute axial rotor displacement relative to the machine casing caused by thermal expansion during startup and shutdown. Electrically configured with a fixed input impedance of 10 kΩ, it supports the monitor's control logic which processes both the magnitude and direction of differential expansion across four programmable alert thresholds consisting of two over-alarm and two under-alarm setpoints. This passive terminal architecture is executed without onboard electromechanical relay contacts, operating instead as a direct signal pass-through and recorder distribution hub for continuous machinery protection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81544-01 (78462-02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Monitor Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/45 Dual Differential Expansion Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Independent channels (Channel B can be turned OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Interfacing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Proximity probe transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Capacity Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Setpoints total (2 Over-alarms, 2 Under-alarms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo onboard relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 10 kΩ input impedance is optimized to match the output parameter of standard Bently Nevada Proximitor sensors, ensuring zero signal degradation across the differential expansion measurement arc.\u003c\/li\u003e\n\u003cli\u003eWhen single-point axial measurements are required on smaller machine casings, Channel B must be programmatically disabled within the 3300\/45 monitor to suppress open-circuit gap voltage faults.\u003c\/li\u003e\n\u003cli\u003eBecause the 81544-01 contains no mechanical relays, all interlocking alarm and trip execution commands must be processed via the system backplane to an adjacent 3300 system relay module.\u003c\/li\u003e\n\u003cli\u003eThermal expansion changes during turbine ramp-up alter the baseline gap voltage; raw recorder outputs from this terminal map these proportional DC shifts for trend plotting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplement rigorous shield grounding at the designated terminal strip block, ensuring the outer shield drain wire of the proximity probe extension cable is tied to instrument ground while remaining isolated at the sensor housing.\u003c\/li\u003e\n\u003cli\u003eMaintain separate wire routing paths for the low-impedance sensor inputs and any neighboring high-voltage AC control circuits to avoid cross-talk within the TSI panel enclosure.\u003c\/li\u003e\n\u003cli\u003ePrior to commissioning, verify that terminal lug screws are tightened to standard torque specifications to eliminate intermittent gap voltage fluctuations caused by physical contact resistance.\u003c\/li\u003e\n\u003cli\u003eEnsure proper spacing and mechanical alignment when sliding the 81544-01 terminal block onto the rear rack connectors to prevent pin distortion or open circuit paths on the 3300 backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 81544-01 terminal block module include mechanical relay contacts for driving local trip solenoids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the 81544-01 is designated as a No Relays module; it routes raw transducer and recorder signals, relying on the 3300 backplane to pass alarm states to a dedicated relay module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this component be utilized with any standard 3300 series proximity probe monitor, such as a radial vibration module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this part number is mapped directly to the hardware parameters of the 3300\/45 Dual Differential Expansion Monitor and cannot be substituted into other monitoring slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the technical function of the alternate part number 78462-02 listed on the assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The number 78462-02 represents the bare raw board or sub-assembly designation used during production, which corresponds identically to the complete top-level part number 81544-01.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860306795,"sku":"81544-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-81544-01-xducr-i-o-and-record-terminals-phquym4p1wm_e2995e0f-7667-420e-acd8-3471ac8b1dcc.jpg?v=1765449280"},{"product_id":"bently-nevada-133827-01-3500-60-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 133827-01 3500\/60 RTD\/TC Non-Isolated I\/O  Module","description":"\u003ch3\u003eCore Product Insights\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(133827-01) functions as a high-reliability\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRTD\/TC Non-Isolated I\/O Module designed for External Terminations. This module interfaces directly with external terminal blocks to process critical temperature inputs from Resistance Temperature Detectors (RTDs) and Thermocouples (TCs). In heavy industries such as petrochemical refining, LNG processing, and power generation, thermal anomalies indicate impending machinery failure. By delivering continuous, high-precision thermal monitoring to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Protection System, this component prevents catastrophic failures, eliminates false trips, and significantly reduces un-scheduled industrial downtime.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture \u0026amp; Interface Options\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware is engineered for high-density signal processing within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erack backplane. It serves as the physical link between field-mounted temperature sensors and the main\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitor card. The external termination architecture allows engineers to route field wiring to a separate termination block located outside the main rack enclosure. This setup simplifies high-density cabinet wiring, facilitates rapid maintenance, and improves cable management. The non-isolated circuit design relies on correct system-level grounding and external premium shielding to maintain signal integrity across long-distance industrial sensor runs.\u003c\/p\u003e\n\u003ch3\u003eCrucial Data Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\u003c\/strong\u003e Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD\/TC Non-Isolated I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e244 mm x 23 mm x 112 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 W typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Input Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum RTD, Copper RTD, Nickel RTD, Type E\/J\/K\/T\/S\/R Thermocouples\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 133827-01 handle signal noise given its non-isolated design?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module relies on high-quality external shielded twisted pair cabling and a single-point industrial ground network. Engineers must ensure proper shield termination at the external block to mitigate common-mode noise interferences.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary advantage of selecting external terminations over internal ones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExternal terminations allow maintenance personnel to replace the I\/O module without disconnecting any field wiring. This layout drastically minimizes human wiring errors during field replacement procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module mix RTD and Thermocouple inputs on the same card simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitor software allows independent channel configuration. You can program specific channels for RTDs and others for Thermocouples on the same\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterface.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Deployment \u0026amp; Wiring Engineering Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGround all sensor wire shields strictly at the external termination block. Do not ground the shield at the sensor end in the field. This prevents dangerous ground loops from corrupting the micro-volt signals of the thermocouples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen fastening the I\/O module to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003echassis rear rails, tighten the retaining chassis screws to exactly\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 N m\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof torque to prevent backplane connector strain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Routing Guidelines:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the external termination cables are routed away from high-voltage AC motor lines or variable frequency drives (VFD) to protect the non-isolated circuitry from electromagnetic cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861289835,"sku":"133827-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133827-01-pc-board-plc-add-on-board-taordovzb0n_6f56e6e5-a692-4318-9449-b1d0067d7924.jpg?v=1765449309"},{"product_id":"bently-nevada-135489-04-3500-40m-proximitor-i-o-module-with-internal-barriers","title":"Bently Nevada 135489-04 3500\/40M Proximitor I\/O Module with Internal Barriers","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e (135489-04) is a high-performance Input\/Output module specifically engineered for the Bently Nevada \u003cstrong\u003e3500\/40M\u003c\/strong\u003e Proximitor Monitor system. This four-channel interface is designed to bridge field transducers with the machinery protection rack, providing integrated \u003cstrong\u003eInternal Barriers\u003c\/strong\u003e and \u003cstrong\u003eInternal Terminations\u003c\/strong\u003e. This configuration is critical for hazardous area installations, as the built-in safety barriers limit electrical energy to prevent ignition in explosive atmospheres.\u003c\/p\u003e\n\u003cp\u003eThe module processes pulse and displacement signals from proximity transducers to monitor essential machinery parameters, including radial vibration, thrust position, eccentricity, differential expansion, and REBAM. By delivering continuous machinery protection and high-fidelity data to operations personnel, the \u003cstrong\u003e135489-04\u003c\/strong\u003e serves as a vital component in reducing unscheduled downtime for critical assets in power generation, oil and gas, and petrochemical processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture \u0026amp; Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e module is designed with a high-density architecture that supports up to four proximity transducer signals simultaneously. It features internal galvanic isolation and safety components that comply with CSA-NRTL\/C and ATEX\/IECEx entity parameters.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Programming\u003c\/strong\u003e: Monitor channels are programmed in pairs, allowing the system to perform up to two distinct functions at once (e.g., Channels 1 and 2 monitoring radial vibration while Channels 3 and 4 monitor thrust).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Barriers\u003c\/strong\u003e: The module incorporates a Proximitor Barrier circuit with specific power (PWR) and signal (SIG) parameters, ensuring Vmax and Imax levels remain within safe operational limits for intrinsic safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conditioning\u003c\/strong\u003e: The hardware provides advanced filtering capabilities, including direct filters (up to 4000 Hz), gap filters, and constant Q notch filters for 1X and 2X vector tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e135489-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor I\/O Module with Internal Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 4 Proximity Transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.7 Watts Typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the internal barrier affect the field wiring requirements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e includes built-in safety barriers, which eliminates the need for external zener barriers or galvanic isolators between the rack and the hazardous area. This simplifies cabinet layout and reduces overall loop impedance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used for both radial vibration and thrust position?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 3500\/40M monitor paired with this I\/O module allows channels to be configured in pairs for different functions, such as radial vibration on one pair and thrust position on the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary entity parameters for the internal barriers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the Proximitor Barrier (PWR), the Vmax is 26.25 V and Imax is 110.48 mA. For the Signal (SIG), Vmax is 13.65 V and Imax is 2.74 mA.\u003c\/p\u003e\n\u003ch3\u003e🛠️ Installation Guide \u0026amp; Key Steps\u003c\/h3\u003e\n\u003cp\u003eThe 135489-04 is an I\/O module with \u003cspan\u003eInternal Barriers\u003c\/span\u003e and \u003cspan\u003eInternal Terminations\u003c\/span\u003e . It mounts at the rear of the 3500 rack, directly behind the \u003cspan\u003e3500\/40M Proximitor Monitor\u003c\/span\u003e . It provides intrinsically safe (IS) isolation for transducers located in hazardous areas .\u003c\/p\u003e\n\u003ch4\u003e1. Hardware Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eBypass Channels:\u003c\/span\u003e Before inserting the module, place the associated monitor channels in \u003cspan\u003eBypass\u003c\/span\u003e mode to prevent accidental machinery trips.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eSlot Alignment:\u003c\/span\u003e Insert the I\/O module into the full-height slot at the rear of the rack that corresponds exactly to the 3500\/40M monitor module in the front .\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eSeating \u0026amp; Securing:\u003c\/span\u003e Guide the module along the chassis rails until it connects firmly with the backplane connectors. Tighten the two thumb screws on the front panel.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eIS Grounding:\u003c\/span\u003e The 3500 rack \u003cspan\u003emust contain a 3500\/04 IS Earthing Module\u003c\/span\u003e. Ensure that the grounding fingers on the rear of the I\/O module make secure contact with the rack's IS earth bus bar.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Wiring \u0026amp; Physical Separation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eColor-Coded Terminals:\u003c\/span\u003e Connect hazardous area transducer field wiring to the \u003cspan\u003eBlue\u003c\/span\u003e terminals. Connect safe area output signals to the \u003cspan\u003eGreen\u003c\/span\u003e terminals.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003e50 mm (2 in) Spacing:\u003c\/span\u003e Maintain a minimum physical distance of \u003cspan\u003e50 mm (2 inches)\u003c\/span\u003e between hazardous (intrinsically safe) wiring and non-hazardous (safe area) wiring.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eRouting Path:\u003c\/span\u003e Route hazardous area wiring upward into the upper wiring troughs and safe area wiring downward into the lower wiring troughs to prevent cross-contamination of signals.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e🛒 Procurement Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNo Bussed Transducers:\u003c\/strong\u003e Internal barrier I\/O modules \u003cspan\u003edo not support\u003c\/span\u003e bussed transducers (shared power lines). Each transducer must be wired independently.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Depth Requirements: \u003c\/strong\u003eInternal barrier modules are deeper than standard I\/O modules. They \u003cspan\u003ecannot fit into standard 400 mm deep cabinets\u003c\/span\u003e. A minimum cabinet depth of \u003cspan\u003e600 mm\u003c\/span\u003e or a Bulkhead\/Panel-mount housing is required.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSlot Count Reduction:\u003c\/strong\u003e Installing the mandatory 3500\/04 IS Earthing Module consumes one dedicated I\/O slot. This reduces the maximum number of available monitor slots in a standard 19-inch rack \u003cspan\u003efrom 14 down to 13\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInternal Terminations Only: \u003c\/strong\u003eThis specific model (-04) features internal screw terminals. It \u003cspan\u003ecannot be used\u003c\/span\u003e with External Termination Blocks (ETBs) or pre-fabricated cables.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Restrictions: \u003c\/strong\u003eRacks equipped with internal barriers have a narrower operating temperature range of \u003cspan\u003e0°C to +65°C\u003c\/span\u003e (32°F to +150°F), compared to the standard -30°C lower limit. Ensure proper cabinet ventilation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863583595,"sku":"135489-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-04-i-o-module-with-internal-barriers-and-internal-terminations-pfud1qtzn2t_898c93e6-a81e-4c17-af39-a2ae95a5f4a2.jpg?v=1765449377"},{"product_id":"bently-nevada-3500-20-02-01-00-135031-01-rack-interface-i-o-module","title":"Bently Nevada 3500\/20-02-01-00 135031-01 Rack Interface I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/20-02-01-00 135031-01\u003c\/strong\u003e is a specialized rear-facing interface component that serves as the essential input\/output hub for the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. This hardware combination pairs the \u003cstrong\u003e3500\/20\u003c\/strong\u003e Rack Interface Module (RIM) structure with the \u003cstrong\u003e135031-01\u003c\/strong\u003e backplane interface board, incorporating dual RS422\/RS485 serial communication ports and a dedicated RS232 configuration port. The assembly processes proprietary configuration protocols and machinery status data, enabling direct connectivity between monitoring racks, configuration software utilities, and plant host control networks. Beyond digital serial communications, the hardware integrates built-in \u003cstrong\u003esystem contacts\u003c\/strong\u003e including specialized hardware lines for remote rack resetting and a dedicated \u003cstrong\u003eNot-OK Relay\u003c\/strong\u003e configuration to transmit system status faults directly to supervisory automation systems without interrupting the critical machinery protection monitoring path.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete integrated communication assembly combining the \u003cstrong\u003e3500\/20-02-01-00\u003c\/strong\u003e ordering configuration and the \u003cstrong\u003e135031-01\u003c\/strong\u003e serial interface board.\u003c\/li\u003e\n\u003cli\u003eDual independent serial ports configurable for RS422 or RS485 communication protocols via backplane hardware selection.\u003c\/li\u003e\n\u003cli\u003eDedicated front-panel and rear-board RS232 connections optimized for field diagnostics and rack configuration tools.\u003c\/li\u003e\n\u003cli\u003eOnboard dedicated hardware \u003cstrong\u003esystem contacts\u003c\/strong\u003e supporting remote Rack Reset commands and external Configuration Lock mechanisms.\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eNot-OK Relay\u003c\/strong\u003e providing an automated hardware contact trip if a fault is detected in any monitoring channel.\u003c\/li\u003e\n\u003cli\u003eNon-interfering communication architecture ensuring data polling and configurations do not impact the baseline machinery protection path.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSerial Modbus or proprietary communication linking vibration monitoring racks to industrial PLCs and Distributed Control Systems (\u003cstrong\u003eDCS\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eRemote plant machinery asset tracking and centralized multi-rack configuration management.\u003c\/li\u003e\n\u003cli\u003eIntegrating hardware-level rack fault warnings with safety interlock loops via the system contact relays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrdering Code \/ Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/20-AXX-BXX-CXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Interface Module complete ordering matrix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Interface I\/O Module with RS422\/RS485 Internal Terminations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Option: RS232\/RS422\/RS485 Serial Communications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: None.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e135031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eI\/O Board Component:\u003c\/strong\u003e Rack Interface I\/O Module with RS422\/RS485 Internal Terminations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125744-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMain Component:\u003c\/strong\u003e Rack Interface Module (Front-facing card).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombined Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/20-02-01-00 135031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Interface I\/O Module with Serial Communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS422 and RS485 (Switch-selectable protocols)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 protocol via 9-pin D-sub connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNot-OK Relay Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A @ 24 Vdc or 120 Vac, epoxy-sealed SPDT design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Input Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Reset, Configuration Lock, and Trip Multiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Card Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Card Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe terminal interfaces and visual indicators on the \u003cstrong\u003e3500\/20-02-01-00 135031-01\u003c\/strong\u003e layout provide specific signaling and connection tracking:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePort \/ Terminal Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel indicator; remains lit green when the interface processes software tasks without internal fault.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTX\/RX LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel indicator; flashes to show active digital data transmission over the backplane bus.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCONFIG Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-facing 9-pin RS232 port dedicated to connecting a field PC running configuration software.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHOST Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear \u003cstrong\u003e135031-01\u003c\/strong\u003e 9-pin RS232 connection utilized for host data polling interfaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRACK RS422 \/ RS485\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal termination screw blocks for routing long-distance serial networks to the plant control room.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSYSTEM CONTACTS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear terminal block pins assigning lines for Rack Reset, Configuration Lock, and Not-OK relay outputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Allocation:\u003c\/strong\u003e Mount the companion front card exclusively into Slot 1 of the chassis frame, which is located directly adjacent to the power supply bay, and attach the \u003cstrong\u003e135031-01\u003c\/strong\u003e interface module into the corresponding rear slot position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Selection:\u003c\/strong\u003e Set the internal hardware termination switches on the \u003cstrong\u003e135031-01\u003c\/strong\u003e circuit card to properly match the designated plant RS422 or RS485 balanced transmission network parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Termination:\u003c\/strong\u003e For end-of-line installations on a long-distance multi-drop serial bus, enable the onboard line-termination resistors to prevent signal reflections and data loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity Wiring:\u003c\/strong\u003e Connect a physical external keyswitch to the Configuration Lock contacts on the rear terminal block to protect the rack configuration from unauthorized or accidental software changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocol:\u003c\/strong\u003e Ensure the serial data cable shields are securely terminated at the chassis ground block to prevent electromagnetic interference from distorting high-speed communication bursts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Low Voltage Directive 2014\/35\/EU, EN 61010-1 Standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e 2011\/65\/EU European Compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American Approvals:\u003c\/strong\u003e cNRTLus Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx Approvals:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the functional connection between the 3500\/20-02-01-00 code and the 135031-01 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/20-02-01-00\u003c\/strong\u003e represents the exact multi-digit factory ordering structure which mandates serial communications and specific internal terminal layouts, while the \u003cstrong\u003e135031-01\u003c\/strong\u003e is the exact manufacturer manufacturing part number assigned to the physical rear I\/O circuit board delivered inside that combination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I toggle the rear serial port network options between RS422 and RS485 protocols?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe selection between protocols requires adjusting the physical positioning of hardware micro-switches located directly on the \u003cstrong\u003e135031-01\u003c\/strong\u003e rear card assembly prior to powering the device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill an absolute failure of this interface module interrupt the machinery protection trip loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module functions outside the primary, direct hardware monitoring path, meaning a complete loss of communication or power to this card has zero impact on the baseline asset trip loops or monitoring execution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a module fault occurs anywhere across the 3500 rack chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated Not-OK Relay contact loop hosted on the backplane block immediately shifts its hardware switch state, providing an instant hardwired system alert to an external PLC or alarm panel.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864075115,"sku":"135031-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-20-02-01-00-135031-01-rack-interface-i-o-module-jytao5rpj3n_3f8ea88d-edeb-4043-ac6e-7df04fa03052.jpg?v=1765449387"},{"product_id":"bently-nevada-3500-33-03-00-149992-03-low-current-16-channel-relay-output-module","title":"Bently Nevada 3500\/33-03-00 149992-03 Low Current 16-Channel Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/33-03-00 149992-03\u003c\/strong\u003e is a full-height 16-channel relay output module designed to provide advanced programmable safety voting and alarm drive logic for the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. As a factory-configured low-current assembly, the \u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e features specialized gold-plated relay contacts engineered specifically to ensure maximum contact integrity and prevent surface oxidation in low-power signaling applications. Each of its sixteen independent outputs possesses dedicated \u003cstrong\u003eAlarm Drive Logic\u003c\/strong\u003e, allowing operators to program complex combinational AND\/OR logic gates utilizing alert, danger, or Not-OK statuses gathered from any vibration, position, or temperature monitor module across the rack. This combined hardware and software solution serves as a highly reliable, hardware-voted emergency trip bridge between critical plant rotating assets and external Distributed Control Systems (\u003cstrong\u003eDCS\u003c\/strong\u003e), programmable logic controllers (\u003cstrong\u003ePLC\u003c\/strong\u003e), or Emergency Shutdown Systems (\u003cstrong\u003eESD\u003c\/strong\u003e).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete integrated 16-channel safety relay assembly consisting of the \u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e system code and the \u003cstrong\u003e149992-03\u003c\/strong\u003e gold-contact main processor board.\u003c\/li\u003e\n\u003cli\u003eOnboard gold-plated contacts optimized for highly stable low-voltage and low-current circuit switching.\u003c\/li\u003e\n\u003cli\u003eHighly flexible \u003cstrong\u003eAlarm Drive Logic\u003c\/strong\u003e matrix supporting customized voting schemes based on multi-channel alert and danger variables.\u003c\/li\u003e\n\u003cli\u003eLive-swap hot-pluggable architecture enabling seamless physical card replacement without disturbing adjacent online machinery protection loops.\u003c\/li\u003e\n\u003cli\u003eIndividual hardware switch assignments on the circuit board allowing independent Normally Energized (\u003cstrong\u003eNE\u003c\/strong\u003e) or Normally De-energized (\u003cstrong\u003eNDE\u003c\/strong\u003e) configuration per relay.\u003c\/li\u003e\n\u003cli\u003eClear front-panel LED diagnostics providing real-time visual assessment of module health (OK), backplane communication bus activity (TX\/RX), and individual channel alarm states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-current alarm link interfaces connecting heavy rotating machinery protection racks to industrial PLCs and safety controllers.\u003c\/li\u003e\n\u003cli\u003eDistributed logic voting and automated emergency shutdown mapping for high-criticality steam turbines, gas turbines, and compressors.\u003c\/li\u003e\n\u003cli\u003eMulti-point protective trip signaling inside demanding petrochemical facilities, oil refineries, and power generation stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrdering Code \/ Component Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-Channel Relay Module complete assembly with Low Current Relays, No Agency Approvals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Current Relay Module option (utilizes Output Module with Gold Contacts).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: None.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e149992-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMain Board Component:\u003c\/strong\u003e Low Current 16-Channel Relay Main Module with Gold-Plated Contacts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombined Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-Channel Relay Module (Low Current Gold Variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Contact Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, double-throw (SPDT) \/ Gold-plated contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Contact Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 V, 1 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Contact Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Vdc at 2 A resistive \/ 48 Vdc at 0.2 A resistive \/ 125 Vdc at 0.1 A resistive \/ 250 Vac at 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Operation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnboard switch-selectable for Normally De-energized (NDE) or Normally Energized (NE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Card Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Card Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg (1.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.41 kg (0.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe diagnostic readouts on the front and the physical terminations on the rear facilitate distinct interface tracking:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description \/ Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel health light; remains solid green when internal software algorithms process normally.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTX\/RX LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel communication light; flashes rapidly to indicate active digital backplane traffic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCHALRM LEDs (1 - 16)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel status lights; independent LEDs illuminate directly to show when a specific relay channel is tripped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Terminal Block Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O backplane connection pins grouping Common (COM), Normally Open (NO), and Normally Closed (NC) lines.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Mode Toggles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhysical multi-position dual-throw onboard switches assigning individual channel states to NDE or NE.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Positioning:\u003c\/strong\u003e Slide the complete \u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e module assembly into any available full-height slot located strictly to the right of the Transient Data Interface (\u003cstrong\u003eTDI\u003c\/strong\u003e) module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Alignment:\u003c\/strong\u003e Secure the corresponding 16-channel internal termination input\/output module (such as 149986-01) into the matching rear slot directly behind the main card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Switch Configuration:\u003c\/strong\u003e Adjust the internal physical toggle switches to determine the required Normally Energized or Normally De-energized status for each channel before sliding the board into the live slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Voltage Verification:\u003c\/strong\u003e Confirm that the downstream instrumentation loops comply strictly with low-voltage and low-current constraints; introducing heavy inductive or high-power loads will destroy the gold-plated contact surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Deployment:\u003c\/strong\u003e Open the system rack software suite to map and download the intended AND\/OR safety voting matrix into the module non-volatile memory prior to system testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU (EMC Directive).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Low Voltage Directive 2014\/35\/EU, EN 61010-1 Standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e 2011\/65\/EU European Compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e cNRTLus Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc \/ Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx Approvals:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the functional relationship between the 3500\/33-03-00 code and the 149992-03 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e represents the complete factory ordering model number specifying a 16-channel relay system configured for low-current applications, while the \u003cstrong\u003e149992-03\u003c\/strong\u003e is the exact manufacturer part number printed on the physical low-current main processor board included in that specific combination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is gold plating critical for the contacts on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGold plating is vital for low-current circuitry (down to 1 V, 1 mA) because standard silver contacts develop surface oxidation layers over time under low electrical loads, whereas gold resists tarnish to guarantee a clean connection path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I perform a hot-swap on this module while machinery monitoring is actively running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the unit features a fully hot-swappable architecture, allowing maintenance teams to remove or insert the card into the slot without disconnecting power or causing signal drops on adjacent monitor channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes a single order of this product supply both the front processor and the rear terminal board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen purchased as a complete surplus or spare assembly assembly under these factory specifications, it typically denotes the main card; ensure you verify whether your specific system panel requires the matching 149986-01 rear internal termination block as well.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865549675,"sku":"3500\/33-03-00 149992-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-03-00-149992-03-spare-16-channel-low-current-relay-output-module-mybdn1u1yaf_20bc0d4c-1b25-4073-ac9e-559a8b4766c0.jpg?v=1765449433"},{"product_id":"bently-nevada-3500-61-01-01-133835-02-temperature-monitor-isolated-i-o-module","title":"Bently Nevada 3500\/61-01-01 133835-02 Temperature Monitor Isolated I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e133835-02\u003c\/strong\u003e) is a high-performance Temperature Monitor Isolated Input\/Output (I\/O) Module featuring internal terminations. Designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Protection System, this module provides continuous tracking of machinery temperature variables to protect critical assets such as turbines, compressors, and large pumps from thermal damage.\u003c\/p\u003e\n\u003cp\u003eThis specific isolated configuration is engineered to eliminate ground loop interference, ensuring reliable data flow and preventing false trips in demanding environments like petrochemical refineries and power plants. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the specific hardware component for isolated I\/O with internal termination resistors, facilitating direct thermocouple readings to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebackplane.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e (\u003cstrong\u003e133835-02\u003c\/strong\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated Thermocouple I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated Thermocouples (Type E, J, K, T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 W maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 VDC galvanic isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 103.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eAccurate identification of the model suffix is required to ensure compliance with hazardous area certifications and hardware compatibility.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e: Temperature Monitor Series Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Isolated Thermocouple I\/O Module with Internal Terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Agency Approval (CN, ATEX, and IECEx for Zone 2 and Class I, Division 2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003ch3\u003eInstallation Steps\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Inspection\u003c\/strong\u003e: Examine module pins for damage and verify that jumper settings on the monitor card match the intended sensor type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module Installation (Rear)\u003c\/strong\u003e: Align the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the rear chassis guides of the target slot. Seat the module firmly into the backplane and secure the thumb screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor Module Installation (Front)\u003c\/strong\u003e: Insert the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor card into the front slot directly opposite the I\/O module. Secure with front panel screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring\u003c\/strong\u003e: Connect sensor leads directly to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal blocks. For Thermocouples (TC), ensure correct polarity of positive and negative extension wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Utilize the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfiguration Software via the TDI port to define sensor types and set Alert\/Danger setpoints before downloading to the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eTechnical Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Terminations\u003c\/strong\u003e: This design allows field wiring to connect directly to the I\/O module, eliminating the need for external terminal blocks and reducing cabinet space requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Failure Protection\u003c\/strong\u003e: The module features built-in detection for broken wires. A sensor fault triggers a \"Not OK\" status, alerting the DCS while preventing accidental machine trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Constraints\u003c\/strong\u003e: This specific configuration (\u003cstrong\u003e-01\u003c\/strong\u003e) is dedicated to isolated thermocouple inputs. It cannot mix RTD and thermocouple signals on the same I\/O block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat certifications does the -01 approval option provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt includes ATEX, IECEx, and CN certifications for use in Zone 2 and Class I, Division 2 hazardous environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external resistors for termination?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware contains internal termination resistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is isolation achieved?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides 500 VDC galvanic isolation to protect signal integrity from ground loop interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865779051,"sku":"3500\/61-01-01 133835-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-01-01-133835-02-rtd-tc-non-isolated-with-internal-terminations-otr0qowkozy_008e3679-5f87-4675-9c12-e49f7807f590.jpg?v=1765449441"},{"product_id":"bently-nevada-82926-01-3300-transducer-input-output-and-recorder-terminal-module","title":"Bently Nevada 82926-01 3300 Transducer Input\/Output and Recorder Terminal Module","description":"\u003cp\u003eThe \u003cstrong\u003e82926-01\u003c\/strong\u003e Transducer Input\/Output and Recorder Terminal Module is a rear-mounting backplane interface engineered for the Bently Nevada 3300\/20 Dual Thrust Position Monitor. This module supports two independent channels of continuous shaft axial position monitoring, processing raw DC gap voltage signals derived from proximity probe transducers to detect deviation relative to calibrated machine clearances. By establishing direct signal routing to the 3300 chassis bus, the hardware enables early warning of thrust bearing failure based on the position of the thrust collar relative to the axial bearing babbitt. The control logic of the associated monitor evaluates these dual-channel inputs against programmable alert and danger setpoints, providing isolated recorder terminal outputs for trend tracking and interfacing with emergency shutdown systems without on-board electro-mechanical relays.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82926-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/20 Dual Thrust Position Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShaft axial position \/ Thrust displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Input Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximity probe transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo on-board relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.27 kg (5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module translates the transducer gap voltage into precise axial displacement metrics, measuring how far the shaft has shifted from its calibrated electrical zero point.\u003c\/li\u003e\n\u003cli\u003eTo achieve proper rotor dynamics representation, the external proximity probes must be installed to observe the thrust collar directly rather than an arbitrary shaft shoulder.\u003c\/li\u003e\n\u003cli\u003eBecause the 82926-01 does not include mechanical relays, any active automatic machinery trip functions must be executed via backplane communication to a dedicated 3300 series relay module.\u003c\/li\u003e\n\u003cli\u003eDisconnecting or miswiring the terminal block outputs will register as a transducer fault or an out-of-limit gap voltage error on the front display of the 3300\/20 monitor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplement dedicated shield grounding protocols at the rear terminal strip by landing the proximity probe extension cable shield at the chassis ground terminal and isolating it at the sensor case.\u003c\/li\u003e\n\u003cli\u003eMaintain strict separation between low-voltage transducer input lines and high-voltage AC utility or control wiring to minimize electromagnetic noise injection into the thrust position loop.\u003c\/li\u003e\n\u003cli\u003eEnsure all terminal lug screws are securely torqued during commissioning to prevent drift in the 4-20 mA recorder loops or intermittent sensor faults caused by mechanical vibration.\u003c\/li\u003e\n\u003cli\u003eAlign the module pins perfectly with the 3300 rack backplane before inserting to avoid bending contacts or disrupting cyclic data exchange with adjacent modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 82926-01 terminal module feature integrated mechanical relays for machinery interlocks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the 82926-01 is a passive transducer input\/output and recorder terminal module that passes signal states to the 3300 backplane, requiring a separate relay module for physical contact execution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this terminal module be used to interface with radial vibration or casing velocity monitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this specific part number is designed and mapped exclusively to match the electrical and channel parameters of the 3300\/20 Dual Thrust Position Monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the recorder terminals on this rear module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The recorder terminals provide dedicated, continuous analog outputs proportional to the measured shaft axial position, allowing for direct connection to external DCS or chart recorders.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866499947,"sku":"82926-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-82926-01-i-o-and-record-terminals-relay-module-5onmhshp13c_f9312740-5fab-45b3-a3b6-9cfa1c7c35b5.jpg?v=1765449471"},{"product_id":"bently-nevada-146031-02-3500-22m-100base-fx-fiber-optic-i-o-module","title":"Bently Nevada 146031-02 | 3500\/22M 100Base-FX (Fiber Optic) I\/O Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e146031-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the essential rear interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M Transient Data Interface (TDI)\u003c\/strong\u003e. While the front module executes complex signal processing, this I\/O component establishes the physical layer for network communication and hardware alerting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e146031-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Base-T \/ 100Base-TX Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45 (Shielded)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHost Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500\/22M TDI (e.g., 288055-01)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated \"OK\" Relay (SPDT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRear Chassis Slot (Directly behind TDI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCat5e \/ Cat6 STP (Shielded Twisted Pair)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Bandwidth Data Streaming:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 100Base-TX interface enables seamless streaming of high-resolution waveform data to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. This prevents data bottlenecks during critical transient events (startups\/shutdowns).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe -02 variant incorporates superior circuitry protection compared to legacy versions, shielding the 3500 rack from common-mode noise and surges prevalent in industrial grounding loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic System Health Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK Relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a hardwired interlock to the Distributed Control System (DCS). It instantly signals a TDI hardware failure, ensuring operators never rely on compromised monitoring data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized EMI Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing shielded RJ45 connections, the module maintains signal integrity even when installed in close proximity to high-voltage variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFAQs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 146031-02 support older 3500\/22M front processors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. This module maintains full backwards compatibility with legacy 3500\/22M TDI processors (like the 138607-01). However, it specifically optimizes performance for the newer 288055-01 series to utilize modern Ethernet standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify the \"Brand New\" status of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery unit arrives in original factory-sealed anti-static packaging. The serial number on the PCB matches the outer Bently Nevada label, and the \"OK\" relay contacts show zero cycles. We provide a Certificate of Conformance (CoC) upon request to guarantee authenticity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the critical installation steps for the 146031-02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou must install this module in the rear of the 3500 rack, directly behind the slot occupied by the 3500\/22M TDI. Ensure you use Shielded Twisted Pair (STP) cabling; failing to ground the Ethernet shield via the RJ45 port can introduce noise into the transient data samples.\u003c\/p\u003e\n\u003ch3\u003eCompatibility \u0026amp; Shipping\u003c\/h3\u003e\n\u003ch4\u003eSystem Requirements\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFront Module:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires Bently Nevada 3500\/22M TDI (288055-01 or 138607-01).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCondition Monitoring and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse standard Cat5e or Cat6 STP for data; use 18 AWG to 22 AWG wiring for the OK Relay terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eShipping \u0026amp; Condition\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New, Original Factory Stock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes original Bently Nevada box with internal ESD protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Logistics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe provide express international shipping via DHL, FedEx, and UPS. We apply vacuum-sealing for long-distance maritime transit if requested to prevent oxidation in humid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867548523,"sku":"146031-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-146031-02-transient-data-interface-module-vxatwz05g2c_9c8ca786-0bbb-4941-8e3a-06aecca2c14c.jpg?v=1765449506"},{"product_id":"bently-nevada-135489-01-3500-42m-i-o-module-with-internal-barriers","title":"Bently Nevada 135489-01 3500\/42M I\/O Module with Internal Barriers","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e135489-01\u003c\/strong\u003e is a 4-channel Input\/Output (I\/O) module designed for use with the \u003cstrong\u003e3500\/42M\u003c\/strong\u003e Proximitor Seismic Monitor within the \u003cstrong\u003e3500 Series\u003c\/strong\u003e Machinery Protection System. This specific hardware variant is equipped with \u003cstrong\u003eInternal Barriers\u003c\/strong\u003e and \u003cstrong\u003eInternal Terminations\u003c\/strong\u003e, providing a compact and intrinsically safe interface for transducers located in hazardous industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe module processes signals for \u003cstrong\u003e4 x Prox\/Accel\u003c\/strong\u003e (Proximity or Accelerometer) transducers on channels 1 through 4. By integrating internal safety barriers, the \u003cstrong\u003e135489-01\u003c\/strong\u003e limits the electrical energy sent to the field sensors, preventing potential ignition in explosive atmospheres while eliminating the need for external barrier hardware. It is a critical component for monitoring vibration, position, and seismic activity on high-value rotating assets such as turbines, compressors, and motors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e135489-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Barriers (Internal Terminations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Main Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e3500\/42M\u003c\/strong\u003e Proximitor Seismic Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x Prox\/Accel (Channels 1-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +65 deg C (32 deg F to +150 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C (-40 deg F to +185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eWhen procuring spare parts for a \u003cstrong\u003e3500\/42M\u003c\/strong\u003e system, verify the specific ordering options to ensure the I\/O module matches the rack's termination and barrier requirements.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e: \u003cstrong\u003e135489-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAA Ordering Option\u003c\/strong\u003e: 04\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Description\u003c\/strong\u003e: I\/O Module with Internal Barriers, Internal Terminations, 4 x Prox\/Accel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003ch3\u003eField Wiring \u0026amp; Internal Terminations\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Connection\u003c\/strong\u003e: The \u003cstrong\u003e135489-01\u003c\/strong\u003e utilizes internal terminations, meaning field wiring from the transducers is connected directly to the screw terminals on the module body located at the rear of the 3500 rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Safety\u003c\/strong\u003e: The internal barriers are designed to maintain the integrity of intrinsically safe (IS) circuits. Ensure that wiring segregation is maintained between the IS field wiring and any non-IS cabling within the cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Support\u003c\/strong\u003e: This module is specifically rated for \u003cstrong\u003eProximity\u003c\/strong\u003e and \u003cstrong\u003eAccelerometer\u003c\/strong\u003e inputs. Confirm that the transducer type in the field matches the channel configuration (Channels 1-4) to avoid signal processing errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Steps\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor Pairing\u003c\/strong\u003e: This I\/O module must be installed in the rear slot of the 3500 rack that corresponds to the front-mounted \u003cstrong\u003e3500\/42M\u003c\/strong\u003e monitor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Specifications\u003c\/strong\u003e: Ensure all terminal screws are tightened correctly to maintain a stable electrical connection, especially in environments subject to industrial vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Compliance\u003c\/strong\u003e: For modules used with internal barriers, the operating temperature must be maintained between \u003cstrong\u003e0 deg C and +65 deg C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this I\/O module be used for Velomitor transducers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-01\u003c\/strong\u003e is specified for \u003cstrong\u003e4 x Prox\/Accel\u003c\/strong\u003e. Use with other transducer types may require a different I\/O module variant or specific configuration adjustments within the \u003cstrong\u003e3500\/42M\u003c\/strong\u003e monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"Internal Barrier\" version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt integrates safety barriers directly into the I\/O module, reducing the physical space required in the cabinet and simplifying the wiring architecture for hazardous area applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 3500 system supports hot-swapping, it is standard engineering practice to bypass any associated machinery trips before replacing an I\/O module to prevent unintended shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666869055851,"sku":"135489-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-01-i-o-module-4-channel-internal-barrier-akragbb2a4i_c5513e8d-df36-47f1-b473-bf9c4c7b9969.jpg?v=1765449560"},{"product_id":"bently-nevada-3500-42m-135489-02-proximitor-seismic-i-o-module","title":"Bently Nevada 3500\/42M 135489-02 Proximitor Seismic I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-144\"\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e135489-02\u003c\/strong\u003e\u003cspan class=\"citation-144\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 4-channel Proximitor Seismic I\/O Module with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eInternal Intrinsic Safety Barriers\u003c\/strong\u003e\u003cspan class=\"citation-144 citation-end-144\"\u003e\u003cspan\u003e \u003c\/span\u003eand Internal Terminations designed for the 3500 Series Machinery Protection System.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSeated in the rear slot of the 3500 instrumentation rack, this module serves as the direct hardware interface linking field-mounted sensors to the front-facing 3500\/42M Proximitor Seismic Monitor module.\u003c\/p\u003e\n\u003cp\u003eThe hardware architecture provides two dedicated proximity\/acceleration channels and two specialized Velomitor channels.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-143 citation-end-143\"\u003eEquipped with integrated Zener-type internal barriers, the 135489-02 restricts electrical fault energy traveling from the rack into the field, providing explosion-proof protection for transducers deployed in Class I, Division 1 or Zone 0 hazardous environments without the need for external galvanic isolation panels.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/42M (Rear Barrier Variant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number \/ ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e135489-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor Seismic I\/O Module with Internal Barriers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Proximity\/Acceleration + 2 Velomitor channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Intrinsic Safety Barriers (Internal Zener Barriers)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Multi-position Screw Terminal Blocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Transducers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Proximity Probes, Accelerometers, Velomitors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConditioned Values\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRadial Vibration, Thrust, Eccentricity, Velocity, Acceleration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.201 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eMachinery verification networks operating in hazardous processing environments require exact tracking of rear I\/O card variation codes. Procure components matching the factory keys below.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMain System Core Monitor Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/42M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Order Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e135489-02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAssociated Front Module Counterpart:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/42M Proximitor Seismic Processor Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Notes \u0026amp; Field Wiring Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Wiring and Barrier Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-142 citation-end-142\"\u003eThe 135489-02 card houses integrated explosion protection circuitry.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eField wiring routing out from the module's terminal block must follow strict intrinsic safety segregation guidelines.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKeep all intrinsically safe field transducer cables physically separated from non-intrinsically safe wires by a minimum clearance boundary of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2.0 inches)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDividers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlternatively, install dedicated grounded metal dividers to avoid voltage arc induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Screw Terminal Allocation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField cabling maps directly onto the built-in internal termination blocks. Use high-quality 3-wire twisted-shielded instrumentation cables (18 AWG to 22 AWG copper) to carry low-voltage displacement and acceleration paths.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePreparation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStrip individual conductor insulation jackets back exactly 7 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect outer grounding shields together and anchor them to the clean instrumentation earth rail at the structural cabinet bulkhead.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDo not\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eloop shield drain wires through the proximity signal common (COM) screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Handshake and Safety Restrictions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the 135489-02 limits terminal fault currents through precision internal barriers, plugging non-designated transducer loads into the channel pins can overload the internal Zener elements, destroying the protection loop. Prior to activating sensor excitation power, match the channel selection parameters (e.g., standard proximity probe versus Velomitor configuration) within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto align with specific paired-channel hardware attributes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between the 135489-02 and standard 3500\/42M I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-141 citation-end-141\"\u003eA: The 135489-02 features built-in internal safety barriers.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStandard I\/O versions do not contain intrinsic insulation paths, requiring plants to source and mount independent, external barrier boards when routing sensor leads into classified hazardous plant fields.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the channel structure split into two distinct sensor pairs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The hardware layout dictates specialized input electronics. Channels 1 and 2 are balanced to process voltage variables from high-frequency proximity probes or accelerometers, while Channels 3 and 4 feature targeted current loops designed specifically for active Velomitor-type velocity sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I hot-swap this rear I\/O module while the 3500 rack is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the front-facing 3500\/42M card allows hot-swapping, extracting the rear 135489-02 while powered up breaks the physical sensor feedback loop and cuts excitation paths. This immediately triggers system interlocks and trips connected safety relays. Always change the rack security keyswitch to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emode and establish channel bypass blocks before initiating hardware service.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666869612907,"sku":"135489-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-02-i-o-module-with-internal-barriers-and-internal-terminations-cfy5l5nmfwu_80b4d093-609f-4e33-a266-6b0411b744dd.jpg?v=1765449578"},{"product_id":"honeywell-experion-pks-fta-t-20-digital-output-relay-field-termination-assembly","title":"Honeywell Experion PKS FTA-T-20 Digital Output Relay Field Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Field Termination Assembly (FTA) within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager (SMS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystems. It serves as the physical and electrical interface between the system's digital output modules and the external field equipment.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-load or isolated switching requirements, the FTA-T-20 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 channels of relay-contact outputs\u003c\/strong\u003e. Each channel offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNO (Normally Open)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNC (Normally Closed)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtacts, allowing for flexible fail-safe configurations. By utilizing interposing relays on the FTA, the system protects the sensitive controller electronics from field-side electrical surges and allows the switching of higher voltages and currents (up to 250 Vac or 110 Vdc) than a standard electronic output could handle.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FTA-T-20 is engineered for seamless integration into Honeywell safety and control racks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 independent relay channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSPDT (Single Pole Double Throw) configuration, providing both NO and NC terminals for every channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects to the controller I\/O module via a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem interconnection cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escrew terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor direct connection of field cables, supporting a variety of wire gauges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard DIN-rail mounting for installation in I\/O cabinets or marshalling panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNFS (Non-Fail Safe) Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically used in applications where the safety logic is managed by the controller, and the relay acts as the final switching element.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Relay Contact)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Vac \/ 110 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNO \/ NC (Change-over)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterconnection Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIC-C-07\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminals (T-Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10209\/2\/1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of using an FTA-T (Screw Terminal) over an FTA-E (ELCO)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion is designed for direct field wiring where the cables are terminated individually at the assembly. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ELCO) version is typically used for \"marshalling-to-marshalling\" connections using pre-fabricated multi-core cables. The FTA-T-20 is ideal for cabinets where field sensors\/actuators are wired directly to the I\/O rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC loads on the same FTA-T-20?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the relay contacts are rated for both 250 Vac and 110 Vdc, it is standard engineering practice to keep load types consistent across an FTA to prevent noise and to simplify maintenance. However, since the 8 channels are galvanically isolated from each other, they can technically switch different voltage sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I replace a faulty relay on this FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDepending on the specific hardware revision, the relays on the FTA-T-20 are often socket-mounted. This allows for \"hot-maintenance\" where an individual relay can be replaced without replacing the entire termination assembly or disturbing the wiring of the other 7 channels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that wire ferrules are used when connecting to the screw terminals. This prevents wire fraying and ensures a gas-tight connection, which is critical in corrosive industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable should be routed away from high-power AC lines to prevent induced noise, even though the relay outputs are relatively robust.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor highly inductive loads (such as large solenoid valves or motor starters), it is recommended to install external RC snubbers (for AC) or flyback diodes (for DC) to extend the life of the FTA relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFusing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways ensure that field-side circuits are properly fused. The FTA-T-20 provides the switching logic, but the current-limiting protection should be handled by external terminal fuses or circuit breakers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667743338859,"sku":"FTA-T-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-20-fta-output-module-qqfm5mreu3l_e04138f4-fd7c-4a5d-9cc3-0b76caa2f4a1.jpg?v=1765501439"},{"product_id":"honeywell-fta-t-02-fail-safe-digital-output-fta-24-channel-24-48-60-vdc","title":"Honeywell FTA-T-02 Fail-Safe Digital Output FTA 24-Channel 24\/48\/60 VDC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eFTA-T-02 (FTA-T-02)\u003c\/span\u003e by \u003cspan\u003eHoneywell\u003c\/span\u003e is a high-integrity \u003cspan\u003eFail-safe Digital Output Field Termination Assembly (FTA)\u003c\/span\u003e engineered for seamless integration with Safety Manager and FSC systems. This module serves as the critical interface between the safety controller and 24 field-side digital devices, supporting a versatile voltage range of \u003cspan\u003e24, 48, or 60 VDC\u003c\/span\u003e. Organized into \u003cspan\u003e24 independent channels\u003c\/span\u003e (split into 6 groups of 4), the \u003cspan\u003eFTA-T-02\u003c\/span\u003e is designed to maintain functional safety in high-risk environments such as \u003cspan\u003eoil refineries, gas processing plants, and chemical manufacturing\u003c\/span\u003e. Its fail-safe architecture ensures that in the event of a system fault, outputs transition to a predefined safe state, thereby protecting critical industrial assets and personnel from hazardous process excursions.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Technical Parameter Matrix\u003c\/h3\u003e\n\u003cp\u003eThe following table provides the rigorous technical data required for engineering specifications and procurement alignment, adhering to Google E-E-A-T technical depth standards.\u003c\/p\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eTechnical Parameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFail-safe Digital Output Field Termination Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Channels (6 groups of 4)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 \/ 48 \/ 60 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Continuous Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Voltage (IEC 1010)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 VDC (Category 3) \/ 150 VDC (Category 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 cm2 (AWG 14)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Nm (0.37 ft-lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRail Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN EN TS32 \/ TS35 x 7.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14.5 cm x 7 cm x 5.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations \u0026amp; Safety Integration FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eHow does the \"Fail-safe\" designation impact the operation of the FTA-T-02?\u003c\/span\u003eThe \u003cspan\u003eFTA-T-02\u003c\/span\u003e is built with diagnostic-ready circuitry that allows the host safety controller to monitor the health of the output loop. In the event of a detected internal failure or loss of communication, the module is designed to ensure the digital outputs revert to a \"de-energized\" or safe state, preventing unintended activation of field equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the significance of the 6-group channel architecture?\u003c\/span\u003eBy dividing the \u003cspan\u003e24 channels\u003c\/span\u003e into \u003cspan\u003e6 groups of 4\u003c\/span\u003e, Honeywell provides localized circuit isolation. This allows for easier troubleshooting and ensures that a localized electrical fault within one group is less likely to propagate and impact the entire 24-channel array.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan the FTA-T-02 handle higher voltages than 60 VDC?\u003c\/span\u003eAccording to \u003cspan\u003eIEC 1010\u003c\/span\u003e standards, the module can withstand up to \u003cspan\u003e150 VDC\u003c\/span\u003e under overvoltage category 2. However, for continuous, safe operation of the digital output logic, it is rated for nominal \u003cspan\u003e24\/48\/60 VDC\u003c\/span\u003e systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Deployment \u0026amp; Field Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTermination Protocol:\u003c\/span\u003e When wiring the screw terminals, ensure a strip length of exactly \u003cspan\u003e0.7 cm (0.28 in)\u003c\/span\u003e. Use a precision torque screwdriver to apply \u003cspan\u003e0.5 Nm\u003c\/span\u003e of force. Under-tightening can lead to resistive heating, while over-tightening may damage the AWG 14 lead or the terminal block housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRail Spacing and Heat Management:\u003c\/span\u003e The \u003cspan\u003eFTA-T-02\u003c\/span\u003e requires a used rail length of \u003cspan\u003e14.6 cm\u003c\/span\u003e. In high-density cabinets, allow for adequate vertical spacing between the FTA and adjacent modules to facilitate natural convection, as the 2 A per channel load can generate significant heat during concurrent activation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGrounding for EMC Compliance:\u003c\/span\u003e To maintain the \u003cspan\u003eCE and UL\u003c\/span\u003e certification integrity, ensure the DIN rail is bonded to a low-impedance earth ground. This provides a clear path for electrical transients and protects the fail-safe logic from electromagnetic interference (EMI) originating from nearby power switching equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Resilience \u0026amp; Technical Superiority\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell FTA-T-02\u003c\/span\u003e stands as a benchmark for reliability in the Field Termination Assembly sector. Its robust physical construction (\u003cspan\u003e14.5 cm x 7 cm\u003c\/span\u003e) is optimized for the rigors of industrial control rooms where vibration and thermal fluctuations are constant variables. By utilizing high-quality screw terminals and gold-plated connector pins, the \u003cspan\u003eFTA-T-02\u003c\/span\u003e ensures long-term contact stability. As an \u003cspan\u003eOriginal and New\u003c\/span\u003e component, it offers full compatibility with legacy Safety Manager and FSC platforms, providing a high-availability solution for modernizing safety instrumented systems (SIS) without requiring extensive field-wiring re-engineering.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667751825771,"sku":"FTA-T-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-02-fail-safe-digital-output-module-afgq1sfwuk5_07e51c7d-5b35-4f5b-83e6-76cd00ca3f1b.jpg?v=1765501568"},{"product_id":"honeywell-900b16-0001-controledge-hc900-16-slot-i-o-chassis","title":"Honeywell 900B16-0001 ControlEdge HC900 16-Slot I\/O Chassis","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001 (900B16-0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity 16-slot I\/O rack designed for the Honeywell ControlEdge HC900 Process \u0026amp; Safety Controller system. This chassis serves as the physical and communication backbone for various HC900 I\/O modules, including analog inputs\/outputs and digital inputs\/outputs. Engineered for modularity and scalability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both standard process control and SIL 2 safety-related applications, providing a ruggedized mounting platform with integrated power distribution and backplane communications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlEdge HC900 \/ Series 900\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Slots (for I\/O modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReserved Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated slots for Power Supply and Scanner\/CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistributed 5V and 24V from Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Mount (Internal Cabinet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 2 Certified (when used with appropriate modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade aluminum\/steel hybrid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed internal bus for I\/O scanning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eStructural Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to maximize I\/O density within a single rack footprint. It facilitates the \"hot-swap\" capability of the HC900 system, allowing modules to be replaced while the rest of the rack remains powered and operational. The chassis includes integrated grounding points and terminal block connectors for the power supply, ensuring clean power delivery to sensitive analog instrumentation. It is a critical component for large-scale boiler control, thermal processing, and water treatment applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this chassis include the Power Supply or CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the empty 16-slot rack frame. The Power Supply (e.g., 900P01) and the CPU or Scanner module must be purchased and installed separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix safety and non-safety modules in this rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the HC900 architecture allows for the coexistence of non-safety and safety-critical I\/O within the same chassis, provided the system configuration adheres to the Honeywell Safety Manual guidelines.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667990147435,"sku":"900B16-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-900b16-0001-plc-module-s1z4in1e0wu_03d48335-7db6-4543-a6e4-e6c67c76b1f5.jpg?v=1765504887"},{"product_id":"honeywell-cc-pail51-experion-series-c-low-level-analog-input-module","title":"Honeywell CC-PAIL51 Experion Series-C Low Level Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-71\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-71\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-71\"\u003eCC-PAIL51 (CCPAIL51)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-71\"\u003e\u003cspan\u003e \u003c\/span\u003estands as a high-performance temperature sensing solution within the Honeywell Experion Series-C Mark II I\/O family\u003c\/span\u003e\u003cspan class=\"citation-71 citation-end-71\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-70\"\u003e\u003c\/span\u003eSpecifically engineered for mission-critical thermal monitoring in industries such as hydrocarbon processing and power generation, this Low Level Analog Input (LLAI) module provides high-density support for 16 RTD and Thermocouple (TC) circuits\u003cspan class=\"citation-70 citation-end-70\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-69\"\u003e\u003c\/span\u003eThe module’s core value lies in its high-integrity data qualification; it features a fixed 1-second PV scanning rate coupled with advanced Open Thermocouple Detection (OTD) protection\u003cspan class=\"citation-69 citation-end-69\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-68\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-68\"\u003eBy automatically setting Process Variables to \"Not a Number\" (NAN) upon sensor failure, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-68\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-68\"\u003e\u003cspan\u003e \u003c\/span\u003eprevents erratic control loop responses, effectively reducing plant risk and minimizing expensive unscheduled maintenance caused by instrument degradation\u003c\/span\u003e\u003cspan class=\"citation-68 citation-end-68\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-67\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-67\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-67\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-67\"\u003e\u003cspan\u003e \u003c\/span\u003ehardware is optimized for signal stability and thermal management within high-density cabinet environments\u003c\/span\u003e\u003cspan class=\"citation-67 citation-end-67\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-66\"\u003eComprehensive Sensor Library:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-66\"\u003e\u003cspan\u003e \u003c\/span\u003eNative linearization for a broad spectrum of sensors, including Platinum (100 ohm), Nickel (120 ohm), and Copper (10\/50 ohm) RTDs, as well as ANSI Type J, K, E, T, B, S, and R thermocouples\u003c\/span\u003e\u003cspan class=\"citation-66 citation-end-66\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-65\"\u003eTotal Galvanic Isolation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-65\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides robust 16-channel isolation, including channel-to-channel, channel-to-DCS backplane, and channel-to-power common, shielding sensitive measurements from ground loop interference\u003c\/span\u003e\u003cspan class=\"citation-65 citation-end-65\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1-second update cycle includes a mandatory OTD check before PV propagation.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-64\"\u003e\u003c\/span\u003eIf sensor resistance exceeds 1500 ohms, the system triggers a guaranteed trip to protect control integrity\u003cspan class=\"citation-64 citation-end-64\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-63\"\u003eSeries-C Mark II Innovation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-63\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes the \"tilted\" module design for superior heat dissipation and features a vertical mounting profile to streamline high-density field wiring entry\u003c\/span\u003e\u003cspan class=\"citation-63 citation-end-63\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eCC-PAIL51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eHoneywell Experion Series-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eLow Level Analog (Temperature) Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e16 (Fully Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e1 second (Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eIOTA Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e\n\u003ca href=\"https:\/\/www.plcprotech.com\/products\/dc-tail51-honeywell-series-c-analog-output-24v-iota-module\"\u003eDC-TAIL51\u003c\/a\u003e (Non-Redundant 9-inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eNominal Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e-20 to +100 mV (TC only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eGain Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e0.050% Full Scale Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eTemperature Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e+\/- 20 ppm per deg C Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eCMRR (50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e120 dB Minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eRTD Excitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e1 milliamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e0 to 60 deg C (Standard Series-C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the CC-PAIL51 prevent \"false\" control actions during a sensor break?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-62\"\u003e\u003c\/span\u003eThe module utilizes a \"sample and hold\" OTD cycle\u003cspan class=\"citation-62 citation-end-62\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-61\"\u003e\u003c\/span\u003eIf an open sensor is detected, the Process Variable is set to NAN (Not a Number) and a soft failure is reported\u003cspan class=\"citation-61 citation-end-61\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-60\"\u003e\u003c\/span\u003eThis ensures no invalid data is propagated to the controller, preventing inappropriate PID responses\u003cspan class=\"citation-60 citation-end-60\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the specific IOTA options for this module?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-59\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-59\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-59\"\u003e\u003cspan\u003e \u003c\/span\u003etypically resides on the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-59\"\u003eDC-TAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-59\"\u003e\u003cspan\u003e \u003c\/span\u003eIOTA, which is a 9-inch (228 mm) assembly for non-redundant applications\u003c\/span\u003e\u003cspan class=\"citation-59 citation-end-59\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support millivolt-only inputs without linearization?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-58\"\u003e\u003c\/span\u003eYes, the module supports standard millivolt types ranging from -20 to +100 millivolts, allowing it to interface with specialized non-standard sensing devices\u003cspan class=\"citation-58 citation-end-58\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-57\"\u003eCold Junction Compensation (CJC):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-57\"\u003e\u003cspan\u003e \u003c\/span\u003eAll thermocouple inputs are automatically compensated using a CJC device located on the IOTA\u003c\/span\u003e\u003cspan class=\"citation-57 citation-end-57\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. To ensure accuracy, avoid installing the IOTA near high-heat components that could create localized thermal gradients across the termination assembly. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-56\"\u003eRTD Wiring Integrity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-56\"\u003e\u003cspan\u003e \u003c\/span\u003eFor RTD sensors, lead resistance must be strictly managed (maximum 15 ohms)\u003c\/span\u003e\u003cspan class=\"citation-56 citation-end-56\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-55\"\u003e\u003c\/span\u003eUse high-quality shielded 3-wire or 4-wire cabling to maintain the 120 dB Common Mode Rejection Ratio (CMRR) and prevent noise from distorting low-level temperature signals\u003cspan class=\"citation-55 citation-end-55\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-54\"\u003eSurge Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-54\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module features integrated surge protection per EN 61000-4-5 (1 kV line-to-line, 2 kV line-to-ground)\u003c\/span\u003e\u003cspan class=\"citation-54 citation-end-54\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. For outdoor sensor runs or environments with high lightning risk, external primary surge arrestors are still recommended to protect the IOTA electronics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668023210347,"sku":"CC-PAIL51","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-pail51-low-level-analog-output-ffkuwq3reb5_d4e37d60-6deb-45a2-8082-bc85412bb644.jpg?v=1765505238"},{"product_id":"honeywell-experion-pks-8c-tdoda1-51307149-175-digital-output-iota","title":"Honeywell Experion PKS 8C-TDODA1 (51307149-175) Digital Output IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TDODA1 (51307149-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 32-channel Digital Output Termination Assembly (IOTA) designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform. This \"Single\" IOTA serves as the mounting base and field wiring interface for a single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output module. It is engineered to drive 24 VDC discrete field devices such as solenoid valves, relays, and indicator lamps. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures the signature Series 8 vertical design, which significantly reduces the cabinet footprint while enhancing thermal management through natural convection. This specific version (51307149-175) is factory-treated with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 conformal coating\u003c\/strong\u003e, providing a critical layer of protection against moisture and corrosive atmospheric elements commonly found in industrial processing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODA1 (51307149-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a ruggedized electrical interface for discrete control.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32-Channel Single-Ended Interface\u003c\/strong\u003e: Accommodates 32 digital output channels, allowing for high-density wiring and simplified common-return routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"175\" suffix indicates compliance with ISA S71.04 Class G3, protecting the PCB and components from corrosive gases like Hydrogen Sulfide (H2S) and Chlorine (Cl2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Series 8 Form Factor\u003c\/strong\u003e: Fits onto a standard Series 8 carrier, facilitating an efficient \"chimney-effect\" airflow that keeps the electronic module cool.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Circuit Protection\u003c\/strong\u003e: Designed to work with the I\/O module’s diagnostic capabilities, including short-circuit protection and load monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Friendly Design\u003c\/strong\u003e: Allows for the electronic I\/O module to be replaced (\"hot-swapped\") without disconnecting the field wiring terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307149-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (32-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.60 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA in a redundant configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-TDODA1 is a \"Single\" IOTA, meaning it has only one slot for an I\/O module. For redundant DO applications where two modules back up each other, you must use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eredundant IOTA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum current per channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module can drive typical 24 VDC solenoids, the total current capacity is limited. For high-current loads or high-frequency switching, it is highly recommended to use interposing relays to prevent thermal stress on the IOTA and module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the field power provided to the outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField excitation power (24 VDC) is usually supplied through the Series 8 carrier busbar. The IOTA then distributes this power to the individual channels based on the commands from the C300 controller.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Precautions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse ferrules on all field wiring to ensure reliable contact and prevent stray wire strands from shorting adjacent terminals in the high-density terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the IOTA is firmly snapped into the carrier and that the carrier itself is properly bonded to the instrument ground bar. Inadequate grounding can lead to intermittent diagnostic errors and susceptibility to electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor the \"Blown Fuse\" diagnostics in the Experion software. If a fuse-protected circuit is used, identify and rectify the field-side short circuit before replacing the module or resetting the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Spacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the manufacturer-specified 150 mm clearance above and below the IOTA row to ensure adequate cooling. Overheating is a primary cause of shortened electronic lifespan in high-density DC cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668027765099,"sku":"8C-TDODA1 51307149-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdoda1-51307149-175-digital-output-bussed-irxllnpltok_da87522a-b045-4c95-88b5-ba132f5cec30.jpg?v=1765505296"},{"product_id":"honeywell-experion-pks-8c-paona1-51454469-175-analog-output-module","title":"Honeywell Experion PKS 8C-PAONA1 (51454469-175) Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAONA1 (51454469-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 16-channel Analog Output (AO) module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O architecture. As a core component of the C300 control system, this module converts digital control algorithms into accurate 4-20 mA analog signals to drive final control elements such as valve positioners, variable speed drives, and dampers. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically engineered for high-density deployments, featuring the Series 8 slim vertical form factor that enhances natural convection cooling. This \"175\" variant comes standard with a factory-applied G3 conformal coating, providing essential protection against corrosive atmospheric contaminants. By ensuring stable signal delivery in harsh industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplays a vital role in maintaining process stability and reducing the total cost of ownership through enhanced hardware durability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1 (51454469-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its ruggedized electronics and seamless integration with the Series 8 I\/O Link.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity\u003c\/strong\u003e: Supports up to 16 independent analog loops per module, maximizing I\/O density within the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-HART Signal Path\u003c\/strong\u003e: Dedicated to standard 4-20 mA analog modulation, offering a streamlined and cost-effective solution for control loops that do not require digital HART diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The 51454469-175 hardware revision is specifically treated to resist corrosion from H2S, Cl2, and ammonia, meeting ISA S71.04 Class G3 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Provides comprehensive electrical isolation between field wiring and the internal system bus, protecting the C300 controller from field transients and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Ready\u003c\/strong\u003e: Fully compatible with redundant Series 8 IOTAs, allowing for seamless bumpless transfer in high-availability control applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAONA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51454469-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output (Non-HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.8 Watts Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.20 x 9.80 x 4.20 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an 8C-PAONA1 with an 8C-PAOHA1 (HART version)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 8C-PAOHA1 is generally backward compatible and can reside on the same IOTA. However, you must update the module configuration in the Experion Control Builder to enable the HART features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"Non-HART\" designation mean for my field devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt means this module only transmits the 4-20 mA analog signal. If you have \"Smart\" valve positioners, they will still move correctly based on the current, but the DCS will not be able to read digital diagnostic data or valve signatures from them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the G3 coating on this part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number suffix \"175\" is the primary indicator of the G3 conformal coating. Physically, the board will have a slight uniform sheen compared to non-coated \"100\" series boards when viewed under reflected light.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Impedance Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8C-PAONA1 is designed to drive loads up to a maximum of 600 Ohms. Before commissioning, calculate the total loop resistance including the field wire run and the positioner impedance. High-resistance loops can cause the output to saturate or trigger \"Output Open\" alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). In a redundant configuration, ensure the \"OK\" LED on the partner module is solid green before removing the module being serviced to prevent a process upset.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Noise Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain signal integrity, use individual shielded twisted-pair cables for each AO channel. The shields must be terminated at the IOTA's ground bar to prevent electromagnetic interference from inducing \"jitter\" in the valve control signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031205739,"sku":"8C-PAONA1 51454469-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paona1-51454469-175-analog-output-module-pr3lnm2gi33_9db50288-9e32-48b9-bb61-3adc7964f986.jpg?v=1765505321"},{"product_id":"honeywell-experion-pks-8c-tdila1-51307141-175-digital-input-iota","title":"Honeywell Experion PKS 8C-TDILA1 (51307141-175) Digital Input IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TDILA1 (51307141-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Digital Input Termination Assembly (IOTA) belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. This module acts as the physical and electrical foundation for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PDILA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input module, providing 32 channels of discrete signal acquisition. It is designed to interface with field contacts such as push-buttons, limit switches, and motor starter auxiliary contacts. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered with the signature Series 8 vertical orientation to optimize cabinet space and enhance thermal management through natural convection. This specific variant, identified by part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51307141-175\u003c\/strong\u003e, features a factory-applied G3 conformal coating, making it resilient against corrosive gases and high-humidity environments typical in oil refineries and chemical processing plants.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILA1 (51307141-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for high-speed signal processing and simplified field maintenance.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32-Channel Single-Ended Interface\u003c\/strong\u003e: Provides terminal connections for up to 32 discrete inputs, sharing a common return to maximize wiring density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"175\" suffix ensures the board is treated to withstand harsh environmental conditions, protecting against corrosion from Hydrogen Sulfide (H2S) and Chlorine (Cl2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Form Factor\u003c\/strong\u003e: Mounts onto a Series 8 carrier, allowing for a \"slim\" I\/O profile that significantly reduces the overall footprint of the DCS cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Management\u003c\/strong\u003e: Distributes 24 VDC field excitation power to the input contacts while maintaining electrical isolation for the C300 controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance\u003c\/strong\u003e: The IOTA design allows for the replacement of the electronic I\/O module without disturbing the field wiring connected to the terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDILA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307141-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input (32-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PDILA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Compression Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.65 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 11.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 8C-TDILA1 support redundant input module configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-TDILA1 is a \"Single\" IOTA, meaning it supports only one 8C-PDILA1 module. For redundant applications where two modules monitor the same 32 field points, you must use the redundant version, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILB1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field excitation voltage does this IOTA provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis IOTA is designed for 24 VDC discrete inputs. The 24 VDC power is typically sourced from the system power supply through the Series 8 carrier bus and distributed to the field contacts via the IOTA terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA in a non-corrosive environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the G3 coating (51307141-175) is designed for harsh environments, it is fully compatible with standard control room environments. It provides an extra layer of protection against unexpected humidity or airborne contaminants.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Organization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven the 32-channel density, use fine-stranded wire with ferrules for all connections to the compression terminals. Clear labeling and organized wire ducting are essential to prevent cross-talk and facilitate future troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the IOTA is properly snapped into the Series 8 carrier and that the carrier is bonded to the instrument earth bar. Proper grounding is critical for the internal surge protection circuitry to function correctly during field-side transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the recommended 150 mm clearance above and below the IOTA row. The vertical design relies on the \"chimney effect\" for cooling; obstructing airflow can lead to localized hotspots and premature failure of the inserted I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031304043,"sku":"8C-TDILA1 51307141-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdila1-51307141-175-input-module-hhpp2chb3tf_64736da3-58c9-4b6e-97d0-b96456e712d1.jpg?v=1765505322"},{"product_id":"honeywell-experion-pks-8c-paona2-analog-output-module-non-hart","title":"Honeywell Experion PKS 8C-PAONA2 Analog Output Module (Non-HART)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAONA2 (8CPAONA2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Analog Output (AO) module belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. Engineered for precision and mission-critical reliability, this 16-channel module converts digital control commands from the C300 controller into standard 4-20 mA analog signals. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily used to drive final control elements such as pneumatic valve positioners, variable speed drives (VSD), and dampers. As a \"Series 8\" component, it features a vertical, slimline design that optimizes cabinet density and promotes natural thermal convection. This specific variant is the \"Non-HART\" version, providing a cost-effective solution for control loops where digital field device diagnostics are not required, while maintaining the rugged G3-level environmental protection standard in Honeywell's premium I\/O line.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to integrate seamlessly into the Experion PKS architecture, focusing on signal stability and hardware longevity.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Density\u003c\/strong\u003e: Provides 16 independent analog output channels, allowing for high-density I\/O configurations in a small physical footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries 8 Architecture\u003c\/strong\u003e: Designed to be \"plug-and-play\" with Series 8 IOTAs (Input Output Termination Assemblies), supporting both non-redundant and redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The module is factory-treated with a conformal coating to protect internal circuitry against humidity and corrosive atmospheric contaminants (ISA S71.04 Class G3).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Features robust isolation between the I\/O Link (backplane) and the field-side electronics, preventing ground loops and protecting the C300 processor from field electrical faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Loop Response\u003c\/strong\u003e: Optimized for low-latency signal delivery, ensuring that control valve movements are synchronized with the DCS PID logic for stable process modulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 254.719px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e8C-PAONA2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eAnalog Output (Non-HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e12-bit Minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e5.5 Watts Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e15.00 x 10.00 x 4.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 8C-PAONA2 be used to communicate with HART-enabled valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 8C-PAONA2 can drive a HART-enabled valve positioner using a standard 4-20 mA signal, it\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecannot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eread or write digital HART data. For full HART pass-through and diagnostics, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOHA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule must be used instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle a loss of communication with the controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-PAONA2 features a configurable \"Fail-Safe\" state. In the event of an I\/O Link failure or controller shutdown, each channel can be programmed to Hold Last Value (HLV) or go to a pre-defined safe value (e.g., 0 mA or 4 mA).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with older Series A or Series C IOTAs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-PAONA2 is strictly a Series 8 module and must be mounted on a Series 8 IOTA, such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Single) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Redundant).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance Matching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the total loop resistance (including field wiring and the actuator\/positioner impedance) does not exceed the module's maximum drive capability, typically 600 Ohms at 24 VDC. Exceeding this limit will result in \"Output Low\" errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Procedure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). When replacing a module in a redundant pair, ensure the \"Secondary\" LED is stable before removing the \"Primary\" module to ensure a bumpless transfer of control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse twisted-pair shielded cable for all 16 channels. The shield should be grounded at the IOTA's grounding bar. Proper shielding is critical to prevent electromagnetic interference (EMI) from inducing \"jitter\" in the 4-20 mA output signal, which can lead to premature mechanical wear on valve positioners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668035236203,"sku":"8C-PAONA2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paona2-dcs-backplane-nkoilvcvcx2_ef231f8b-558f-431c-9001-1acf9869e5f7.jpg?v=1765505367"},{"product_id":"honeywell-experion-pks-8c-tdodb1-digital-output-redundant-iota","title":"Honeywell Experion PKS 8C-TDODB1 Digital Output Redundant IOTA","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eHoneywell 8C-TDODB1 (8CTDODB1)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability Digital Output Termination Assembly (IOTA) designed for the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis \"Redundant\" IOTA is a critical infrastructure component that allows two\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-PDODA1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output modules to operate in a 1-out-of-2 (1oo2) configuration.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn this setup,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe primary and secondary modules work in tandem; if the primary module fails,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe secondary module takes over control of the field devices instantaneously without a \"bump\" in the process.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis primarily utilized in sectors requiring mission-critical safety and uptime,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as Emergency Shutdown (ESD) systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eturbine trip circuits,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand critical solenoid header controls in chemical and power plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to provide a robust physical and electrical foundation for redundant digital control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundant Module Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures two dedicated slots for Digital Output modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emanaging the synchronization and load-sharing logic between the two units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e32-Channel Density\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 32 individual digital output channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etypically used for driving 24 VDC solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erelays,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor indicator lamps.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eG3 Conformal Coating\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFactory-treated with a protective layer to ensure long-term reliability in environments with high humidity or corrosive gas concentrations (conforming to ISA G3 standards).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVertical I\/O Design\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes the Series 8 vertical mounting format,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich promotes natural airflow for cooling and reduces the overall footprint within the control cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Blown Fuse Detection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides circuit protection and diagnostic feedback to the C300 controller,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing operators to identify field-side wiring faults or short circuits immediately.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDODB1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Redundant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.75 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 12.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan I use only one module on the 8C-TDODB1 IOTA?\u003c\/strong\u003e\u003cspan class=\"\"\u003eYes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhile the 8C-TDODB1 is designed for redundancy,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit can operate with a single module.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe system will report a \"Redundancy Lost\" alarm until the second module is installed and synchronized.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the difference between 8C-TDODA1 and 8C-TDODB1?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe 8C-TDODA1 is a \"Single\" IOTA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting only one module with no hardware redundancy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis the \"Redundant\" version,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efeaturing two module slots for high-availability applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes this IOTA provide power to the field solenoids?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe IOTA distributes 24 VDC power from the cabinet busbar to the outputs.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe total current capacity is limited per channel.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor high-current solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003einterposing relays should be used to protect the IOTA circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundancy Cable Installation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the redundancy link between the two modules is securely seated.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWithout this link,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe modules cannot synchronize their internal states,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eleading to independent operation and potential control conflicts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eField Wiring Termination:\u003c\/strong\u003e\u003cspan\u003e When wiring the 32 channels,\u003c\/span\u003e\u003cspan\u003e use ferrules to prevent stray wire strands from causing short circuits between adjacent terminals.\u003c\/span\u003e\u003cspan\u003e Given the high density of the 8C-TDODB1,\u003c\/span\u003e\u003cspan\u003e cable management and clear labeling are essential for future troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e\u003cspan\u003e The IOTA must be bonded to the instrument earth bar via the carrier's grounding system.\u003c\/span\u003e\u003cspan\u003e Proper grounding is vital for the correct operation of the blown-fuse detection circuitry and to prevent electromagnetic noise from affecting the I\/O Link communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668035662187,"sku":"8C-TDODB1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdodb1-digital-output-module-nto0msgjdle_0be4d2d8-53a4-4ee4-9ea3-94936ec0e1b4.jpg?v=1765505373"},{"product_id":"honeywell-experion-pks-8c-taoxa1-51307135-175-analog-output-iota","title":"Honeywell Experion PKS 8C-TAOXA1 (51307135-175) Analog Output IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TAOXA1 (51307135-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Analog Output Termination Assembly (IOTA) belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. As a fundamental component of the C300 control environment, this IOTA provides the physical mounting base and field wiring interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output module. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to support 16 channels of 4-20 mA signals, commonly used to drive control valves, actuators, and speed governors in critical process industries such as oil and gas, power generation, and pharmaceutical manufacturing. Its vertical form factor is a signature of the Series 8 design, engineered to promote natural convection cooling and minimize the footprint within high-density control cabinets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1 (51307135-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for rapid installation and long-term signal integrity in demanding industrial settings.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity\u003c\/strong\u003e: Provides dedicated screw terminal points for 16 analog output loops, supporting both redundant and non-redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Mounting Profile\u003c\/strong\u003e: Specifically designed for the Series 8 Slim chassis, allowing for efficient cable management and superior thermal dissipation compared to traditional horizontal racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The 51307135-175 variant is factory-treated with a protective coating to withstand Class G3 harsh environments, preventing corrosion from H2S, Cl2, and other caustic gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Distribution\u003c\/strong\u003e: Manages the distribution of 24 VDC power from the cabinet bus to the inserted I\/O module and the field-side loop, ensuring consistent drive current across all 16 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Interface\u003c\/strong\u003e: Features robust, high-density compression terminals that facilitate secure connections for field cabling, with integrated support for shield grounding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TAOXA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307135-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output (16-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAOXA1 \/ 8C-PAOYA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Compression Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 10.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 8C-TAOXA1 compatible with HART communication modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the IOTA is a passive termination assembly, it is designed to transparently pass HART digital data when paired with an Analog Output module that supports HART (such as the 8C-PAOHA1).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 51307135-175 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 175 suffix specifically denotes the G3 conformal coating. Standard, non-coated versions carry different suffixes. This version is required for any installation where the control room atmosphere is not strictly regulated for corrosive contaminants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA for redundant AO module configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-TAOXA1 is a non-redundant (Single) IOTA. For redundant applications where two modules back up one another on the same field wiring, you must use the redundant version of the IOTA (8C-TAOXB1).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Discipline\u003c\/strong\u003e: When connecting 4-20 mA loops to the 8C-TAOXA1, ensure that signal cables are kept separate from high-voltage AC lines. Use twisted-pair shielded cables and terminate the shield at the IOTA designated ground point to minimize electromagnetic interference (EMI) that can cause valve hunting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Seating\u003c\/strong\u003e: Before applying power, ensure the 8C-PAOXA1 module is fully seated onto the IOTA and the captive mounting screws are tightened. A loose module can cause intermittent Channel Fault or I\/O Link Failure alarms in the Experion System Status Display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAtmospheric Protection\u003c\/strong\u003e: Since this is the 51307135-175 G3-coated version, ensure that when field wiring is completed, the cabinet entries are sealed. The coating protects the board, but terminal connections remain vulnerable to heavy oxidation if the cabinet is left open in a corrosive environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668040085867,"sku":"8C-TAOXA1 51307135-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-taoxa1-51307135-175-analog-output-module-ee5lfji1kt3_bed50637-0f91-47a7-be5b-ee3622df234d.jpg?v=1765505433"},{"product_id":"bently-nevada-172103-01-3500-65-rtd-isolated-tip-tc-i-o-module","title":"Bently Nevada 172103-01 3500\/65 RTD\/Isolated Tip TC I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e172103-01\u003c\/strong\u003e is a 16-channel temperature monitor input\/output (I\/O) module designed for the 3500\/65 machinery protection system rack. It provides physical connection interfaces for resistance temperature detectors (RTDs) and isolated tip thermocouples (TCs). The module features internal terminations, allowing field wiring from temperature sensors to connect directly to the terminal block on the rear of the 3500 rack without requiring external termination blocks.\u003c\/p\u003e\n\u003cp\u003eThis I\/O module interfaces directly with the 3500\/65 monitor module to condition continuously sampled temperature data. It is primarily utilized in critical machinery applications, including steam and gas turbine bearings, large motor stator windings, compressor discharge lines, and industrial pump housing monitoring. The module supports both continuous alarm verification and machinery trip logic integration when combined with the 3500 system relay modules.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003ePart Number:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e172103-01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eManufacturer:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eMonitor Compatibility:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e3500\/65 16-Channel Temperature Monitor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eTermination Type:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eInternal Terminations (Includes 20-pin terminal plug, part number 173005)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eFunctional Group:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Protection System Spare Parts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"NRefec\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"cZCYO firstRow\"\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e172103-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eTemperature Monitor I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e16 independent channels (RTD or Isolated Tip TC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eInput Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u0026gt; 1 MΩ on all transducer inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eExcitation Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e913 μA ± 7 μA constant current source per RTD channel (at 25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e1°C or 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eMeasurement Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e± 3°C (± 5.4°F) at +25°C ambient (includes internal cold junction compensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e3.0 Watts maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eDimensions (H x W x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0% to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eIP20 (when installed in standard 3500 chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Configuration \u0026amp; Sensor Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 172103-01 module accepts a mixed configuration of thermocouples and RTDs within the 3500 Rack Configuration Software. The supported sensor ranges are detailed below:\u003c\/p\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eType E TC (Isolated Tip):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-100°C to +1000°C (-148°F to +1832°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eType J TC (Isolated Tip):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +760°C (32°F to +1400°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eType K TC (Isolated Tip):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +1370°C (32°F to +2498°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eType T TC (Isolated Tip):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-160°C to +400°C (-256°F to +752°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003e100 Ω Platinum RTD (Pt100, alpha = 0.00385):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-200°C to +850°C (-328°F to +1562°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003e100 Ω Platinum RTD (Pt100, alpha = 0.00392):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-200°C to +850°C (-328°F to +1562°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003e120 Ω Nickel RTD (Ni120):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-200°C to +700°C (-328°F to +1292°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003e10 Ω Copper RTD (Cu10):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-80°C to +260°C (-112°F to +500°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eGrounding and Shielding:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTemperature sensor cable shields must be terminated at a single point. Connect the shield wires to the dedicated chassis ground terminals on the 3500 rack. Do not ground the shield at both the sensor end and the module end to prevent ground loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eThermocouple Constraints:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOnly isolated tip thermocouples are compatible with the 172103-01. Grounded tip thermocouples must not be used, as they introduce common-mode voltage errors across channels sharing the same input multiplexer circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eWiring Separation:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRoute low-voltage RTD\/TC signal wires through dedicated, separate cable trays. Avoid proximity to high-voltage motor power leads, variable frequency drive (VFD) outputs, or switching inductive loads to prevent electromagnetic interference (EMI) injection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003e4-Wire RTD Modifications:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStandard internal termination modules are configured for 3-wire RTD compensation. If 4-wire RTD sensors are deployed, check the specific hardware modification code (such as Modification 179952-01) required for physical multi-wire jumper accommodation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eHot Swapping Precautions:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhile the 3500\/65 monitor main card supports online insertion\/removal, disconnecting the 172103-01 I\/O module while the monitor is live will immediately disrupt sensor loops, triggering channel faults and potential rack-level Danger alarms. Bypass any related voting logic or shutdown interlocks prior to module extraction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eCan I use the 172103-01 module with an external termination block?\u003c\/span\u003e\u003cbr\u003eNo. The 172103-01 is explicitly designed for internal terminations where field wiring connects directly to the rack backplane plug. For external termination blocks, the 172109-01 external termination I\/O module must be ordered instead.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eWhat happens if a temperature sensor wire breaks or disconnects?\u003c\/span\u003e\u003cbr\u003eThe 3500\/65 monitor automatically executes a transducer limit check. A broken wire triggers an \"Open Circuit\" or \"Not OK\" status for that specific channel. The Channel OK LED on the front main card will flash, and the channel's output status is driven out of range to prevent false machine trips.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eIs firmware updating required when replacing an older revision I\/O module with a new 172103-01?\u003c\/span\u003e\u003cbr\u003eIf upgrading or replacing an older configuration, verify that the 3500\/65 main monitor card firmware version is compatible. Incompatible firmware may result in configuration mismatches or a continuous \"Configuration Error\" fault in the rack event log.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eHow is Cold Junction Compensation (CJC) managed for thermocouples?\u003c\/span\u003e\u003cbr\u003eThe 172103-01 features a solid-state temperature sensor integrated directly on the terminal block board assembly. This sensor tracks changes in terminal temperature and applies digital compensation factors inside the 3500\/65 monitor processing layer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668298625387,"sku":"172103-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/172103-01-hymuxx01gcp_f9bd0daa-d3f3-4d15-819b-972e3ef918b5.jpg?v=1765520488"},{"product_id":"bently-nevada-135489-02-i-o-module-with-internal-barriers-for-prox-accel-and-velomitor-signals","title":"Bently Nevada 135489-02 I\/O Module with Internal Barriers for Prox\/Accel and Velomitor Signals","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e135489-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada I\/O module designed for safe signal acquisition from proximity, acceleration, and velocity sensors in industrial vibration monitoring systems. It integrates internal barriers and internal terminations to simplify wiring architecture while maintaining intrinsic safety compliance in hazardous area installations. The module is commonly used in turbine protection systems, compressors, and critical rotating machinery where reliable multi-channel vibration input is required for continuous condition monitoring.\u003c\/p\u003e\n\u003cp\u003eThis I\/O module supports 2 proximity or accelerometer channels and 2 Velomitor channels, enabling mixed-sensor configurations within a single module. It is widely deployed in oil and gas facilities, power generation stations, and petrochemical plants where system reliability and reduced wiring complexity directly impact maintenance efficiency and downtime control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 Prox\/Accel channels for shaft vibration and displacement monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 Velomitor channels for casing vibration velocity measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal barriers for intrinsic safety signal isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal terminations for simplified cabinet wiring and reduced installation complexity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe internal barrier design eliminates the need for external isolators, reducing cabinet space requirements and improving system integration efficiency. The module ensures stable signal conditioning between field sensors and monitoring systems while maintaining electrical protection in hazardous environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e135489-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2 Prox\/Accel + 2 Velomitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eVibration displacement and velocity inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Feature\u003c\/td\u003e\n\u003ctd\u003eInternal intrinsic safety barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination\u003c\/td\u003e\n\u003ctd\u003eInternal signal termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eTurbine, compressor, pump monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eIndustrial hazardous areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem rack powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.201 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eRack-mounted I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module handle both proximity and velocity signals simultaneously?\u003c\/strong\u003e\u003cbr\u003eYes. It supports 2 proximity or accelerometer inputs and 2 Velomitor velocity channels in parallel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external signal barriers?\u003c\/strong\u003e\u003cbr\u003eNo. It includes internal barriers, which reduces external wiring and cabinet complexity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with 3500 monitoring systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for integration within Bently Nevada 3500 series monitoring architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a channel fails?\u003c\/strong\u003e\u003cbr\u003eA failed channel will trigger diagnostic alerts in the monitoring system without affecting remaining channels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the module in a properly grounded rack enclosure to maintain signal integrity and intrinsic safety compliance. Poor grounding can introduce measurement noise across all channels.\u003c\/p\u003e\n\u003cp\u003eKeep field wiring separated from high voltage power lines and VFD cables to avoid electromagnetic interference, especially in turbine control cabinets.\u003c\/p\u003e\n\u003cp\u003eVerify correct channel configuration during commissioning. Misconfigured input types (Prox\/Accel vs Velomitor) can lead to incorrect vibration interpretation.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321890667,"sku":"135489-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-02-i-o-module-with-internal-barriers-and-internal-terminations-ph4wmoxwykw_33e1082e-42c4-4eda-8942-5a692bc45121.jpg?v=1765449578"},{"product_id":"bently-nevada-3500-22m-01-01-00-transient-data-interface-with-ethernet-i-o","title":"Bently Nevada 3500\/22M-01-01-00 | Transient Data Interface with Ethernet I\/O","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Transient Data Interface) is the specialized communication and data acquisition processor for the Bently Nevada 3500 series machinery protection system. Unlike the standard 3500\/20 RIM, the \"M\" series TDI provides advanced waveform capture and high-resolution transient data analysis capabilities. This module is the essential link between the rack's internal backplane and external diagnostic software, such as System 1, facilitating real-time monitoring of critical rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel ID:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransient Data Interface (TDI) Module and I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTDI Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOption\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Standard - designed for general machinery monitoring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOption\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(10Base-T\/100Base-TX Ethernet I\/O module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOption\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(None \/ General Purpose)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRJ45 Copper Interface supporting 10\/100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Refresh Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStatic data updated at 100 ms intervals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal non-volatile memory for configuration and event logging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMade in U.S.A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Net Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.11 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Shipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Role and Integration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoccupies the first slot of the 3500 rack, adjacent to the power supplies. It continuously polls data from all vibration, position, and temperature monitors within the rack. By utilizing the 10\/100 Ethernet I\/O, it ensures that high-bandwidth dynamic waveforms are transmitted without latency, which is critical for identifying rotor instability or bearing wear during transient machine states (startup, shutdown, or speed changes).\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 3500\/22M-01-01-00 compatible with older 3500 racks?\u003c\/strong\u003eA: Yes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to be backwards compatible with the 3500 rack chassis, provided the rack backplane supports the TDI architecture. It is the recommended upgrade for legacy 3500\/20 modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the \"00\" Agency Approval limit the module's performance?\u003c\/strong\u003eA: No. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption indicates the unit does not carry specific hazardous area certifications (like CSA or ATEX). It offers identical technical performance to certified units and is ideal for control rooms or non-classified industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322742635,"sku":"3500\/22M-01-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350022m-01-01-00-dak4rp3gmkm_003a628d-19ea-4202-a869-d6aedfb09e6a.jpg?v=1765521208"},{"product_id":"abb-tu838-3bse008572r1-s800-i-o-extended-module-termination-unit","title":"ABB TU838 3BSE008572R1 S800 I\/O Extended Module Termination Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB \u003cstrong\u003eTU838 (3BSE008572R1)\u003c\/strong\u003e is an S800 I\/O Extended Module Termination Unit designed for ABB distributed control systems. It provides the electrical and mechanical interface between field wiring and S800 I\/O modules within System 800xA architectures.\u003c\/p\u003e\n\u003cp\u003eThis MTU distributes process power, routes ModuleBus signals, and supports up to 16-channel I\/O configurations. It is widely used in process automation environments where stable signal termination and modular expansion are required.\u003c\/p\u003e\n\u003cp\u003eThe TU838 supports fused transducer power outputs, redundant L+ \/ L- supply paths, and mechanical coding to prevent incorrect module installation.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16-channel S800 I\/O termination unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with ABB System 800xA and Advant OCS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated fused transducer power distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical keying system prevents incorrect module insertion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN rail mounting with integrated grounding latch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant L+ \/ L- process power support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic ModuleBus sequential addressing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for industrial process automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU838\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE008572R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O (System 800xA \/ Advant OCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e3 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Current\u003c\/td\u003e\n\u003ctd\u003e10 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Power\u003c\/td\u003e\n\u003ctd\u003eL+ \/ L- redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003e100 mA fast-blow (up to 3.5 A field replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Rating\u003c\/td\u003e\n\u003ctd\u003e1.5 A @ 5 V \/ 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e58.5 × 64 × 170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.375 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85369095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Function and Architecture\u003c\/h3\u003e\n\u003cp\u003eThe TU838 operates as a passive termination and distribution module within S800 I\/O systems. It does not process signals but provides structured routing between field devices and I\/O modules.\u003c\/p\u003e\n\u003cp\u003eModuleBus communication uses sequential slot detection, allowing automatic addressing without software configuration. Each MTU passes position signals to the next unit in the DIN rail chain.\u003c\/p\u003e\n\u003cp\u003eThe unit also distributes process power through fused output groups, protecting connected field instruments from overload conditions.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Wiring Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation is required for stable system performance.\u003c\/p\u003e\n\u003cp\u003eMount the unit on a 35 mm DIN rail in a horizontal position. Ensure the DIN rail is properly grounded using low-impedance bonding to the cabinet earth system.\u003c\/p\u003e\n\u003cp\u003eMaintain a wire stripping length of 7 mm and tighten terminal screws to 0.5–0.6 Nm. Use proper separation between signal wiring and AC power lines to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eField wiring is divided into 16 signal channels with grouped fused transducer outputs. Some configurations allow shared fuse groups depending on module design.\u003c\/p\u003e\n\u003ch3\u003eMechanical Keying System\u003c\/h3\u003e\n\u003cp\u003eThe TU838 includes a dual mechanical keying system with six selectable positions per key, enabling 36 configuration combinations.\u003c\/p\u003e\n\u003cp\u003eThis prevents incorrect insertion of S800 I\/O modules such as AI810, DI810, or DO814. The system ensures mechanical compatibility and protects internal circuits from incorrect field voltage exposure.\u003c\/p\u003e\n\u003ch3\u003eEMC and Grounding Requirements\u003c\/h3\u003e\n\u003cp\u003eStable operation requires proper grounding and EMC design.\u003c\/p\u003e\n\u003cp\u003eThe DIN rail acts as a functional earth connection through the integrated latching mechanism. The cabinet must be connected to a low-impedance grounding system using copper braid.\u003c\/p\u003e\n\u003cp\u003eSignal cables should be separated from power cables to minimize noise coupling. Avoid long parallel routing between high-voltage and low-voltage lines.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe ABB TU838 is used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial process automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eABB System 800xA DCS architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale factory automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety-critical instrumentation networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct ID: 3BSE008572R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eABB Type: TU838\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: S800 I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Order Quantity: 1 piece\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of TU838 in S800 I\/O systems?\u003c\/strong\u003e\u003cbr\u003eIt provides signal termination, power distribution, and ModuleBus routing between field wiring and I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes TU838 require software configuration?\u003c\/strong\u003e\u003cbr\u003eNo. Module addressing is handled automatically through sequential ModuleBus signaling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the fuses be replaced?\u003c\/strong\u003e\u003cbr\u003eYes. Fuses are field replaceable and can be upgraded depending on application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if grounding is incorrect?\u003c\/strong\u003e\u003cbr\u003eImproper grounding may lead to EMC interference, unstable signals, or system communication errors.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668497920363,"sku":"TU838 3BSE008572R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu838-3bse008572r1-tu838-extended-module-termination-unit-releuqkxedv_4820a9c5-09fa-4dcf-94fb-295b49e567ab.jpg?v=1765532469"},{"product_id":"abb-3bse061579r1-xf801-s800-i-o-fast-i-o-module","title":"ABB 3BSE061579R1 XF801 S800 I\/O Fast I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eXF801\u003c\/strong\u003e processes high-speed digital signals within distributed automation frameworks, serving as a specialized interface for time-critical subprocess operations. This hardware subassembly operates within the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e platform to execute rapid signal transformation, reducing propagation delays between primary field instrumentation and the controller core. Fully compatible with \u003cstrong\u003eAC 800M Control Software 5.1\u003c\/strong\u003e and broader \u003cstrong\u003eSystem 800xA\u003c\/strong\u003e architectures, the module acts as a fast-response localized subsystem to ensure high-frequency processing demands are met with strict deterministic execution. Its integrated design allows seamless mounting inside standard system line-ups, expanding standard distributed I\/O control topologies into specialized fast-acting process zones.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed cycle processing dedicated for time-critical subprocess monitoring\u003c\/li\u003e\n\u003cli\u003eFull integration alignment within the S800 I\/O and AC 800M controller bus structure\u003c\/li\u003e\n\u003cli\u003eLow propagation delay architecture for optimized signal turnaround performance\u003c\/li\u003e\n\u003cli\u003eForm-factor optimized for standardized panel layout positioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-frequency industrial process tracking\u003c\/li\u003e\n\u003cli\u003eAC 800M distributed controller node expansion\u003c\/li\u003e\n\u003cli\u003eSub-millisecond signal processing sequences\u003c\/li\u003e\n\u003cli\u003eSectional process line automation deployment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXF801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE061579R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFast I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSweden (SE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion:\u003c\/strong\u003e Mount the module carefully onto the designated S800 system station base to ensure complete engagement of structural internal logic connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Prevention:\u003c\/strong\u003e Observe appropriate electro-static handling criteria during unboxing and physical mounting routines to protect fast-switching internal semiconductors from static breakdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Integrity:\u003c\/strong\u003e Ensure sufficient free clearance above and below the operational housing cluster to permit natural thermal convection currents inside the cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Coordination:\u003c\/strong\u003e Confirm that the accompanying AC 800M controller base firmware aligns with Version 5.1 criteria before attempting online device configuration loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat primary platform does this device support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is engineered to operate exclusively as a component within the S800 I\/O distributed hardware system managed by AC 800M controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat distinguishes this component from standard I\/O options?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module provides fast-response processing attributes designed for application paths that cannot tolerate standard digital tracking cycles or traditional latency levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit include physical built-in safety barriers for intrinsic safety application zones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe engineering data establishes this as a standard fast-response processing module; check specific assembly variants for hazardous field circuit boundaries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the precise standalone mass specification for structural weight calculations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe net weight of the unpackaged hardware module is precisely 1 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this device compatible with alternative non-ABB control architectures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this module is developed to attach directly to the proprietary bus structures found in System 800xA and compatible platform segments.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668512665963,"sku":"3BSE061579R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-xf801-3bse061579r1-fast-i-o-module-ottf4psa4v0_f884a379-cc02-4089-81cc-e170916ad377.jpg?v=1765532563"},{"product_id":"abb-tb820v2-3bse013208r1-s800-i-o-modulebus-cluster-modem","title":"ABB TB820V2 3BSE013208R1 S800 I\/O Modulebus Cluster Modem","description":"\u003cp\u003eThe \u003cstrong\u003eTB820V2\u003c\/strong\u003e with part number \u003cstrong\u003e3BSE013208R1\u003c\/strong\u003e is an optical cluster modem designed for non-redundant communication operations within the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e system framework. It functions as a specialized interface for the reception, conversion, transmission, and regeneration of data signals across local or wide area industrial networks. The module establishes secure, fiber-optic links between distributed \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e clusters and central controllers, ensuring noise-immune data transfer in harsh environments. Each unit comes packaged with a dedicated power supply connector and a \u003cstrong\u003eTB807 Modulebus Terminator\u003c\/strong\u003e to ensure correct electrical termination of the local bus cluster.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTB820V2\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e3BSE013208R1: Modulebus Cluster Modem (Non-redundant operation)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTB820V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE013208R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulebus Cluster Modem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O, System 800xA (Versions 4.0, 4.1, 5.0, 5.1, 6.0), Advant OCS with Master SW, Advant OCS with MOD 300 SW, Compact Product Suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x Power Supply Connector, 1 x TB807 Modulebus Terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Architecture Integration\u003c\/strong\u003e: The cluster modem operates within the local Modulebus hierarchy to bridge communication between external controller racks and distributed S800 remote I\/O blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Requirement\u003c\/strong\u003e: Correct bus topology requires the installation of the included TB807 Modulebus Terminator at the physical end of the localized cluster segment to suppress signal reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Redundant Configuration\u003c\/strong\u003e: This hardware variant is optimized strictly for simplex (non-redundant) communication lines; dual-line pathing architectures require alternative module selections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Platform Compatibility\u003c\/strong\u003e: Fully verified for cross-generational deployment, bridging legacy Advant Fieldbus 100 systems with modern System 800xA control configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Assembly\u003c\/strong\u003e: Mount the unit onto its designated backplane slot within the I\/O chassis, securing any mechanical lock latches to ensure solid alignment with the backplane communication rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection\u003c\/strong\u003e: Use only the provided power supply connector block to land the required operational voltages, ensuring correct polarity before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Handling\u003c\/strong\u003e: Avoid sharp bends or pulling stresses on the optical patch cables connected to the modem interface, as excessive attenuation or physical breakage can degrade cyclic data exchange.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Precautions\u003c\/strong\u003e: Adhere to strict industrial ESD measures, including wearing an approved grounding wrist strap, when handling the modem or installing the terminating plug.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What physical accessories are included standard in the box with this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Every unit ships complete with one power supply connector and one TB807 Modulebus Terminator block.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this specific module designation be deployed in a redundant network communication layout?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this unit is engineered and specified strictly for non-redundant network configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this hardware module require any internal backup batteries for configuration retention?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the module operates with zero internal batteries, running completely on external system backplane power.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668514435435,"sku":"3BSE013208R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tb820v2-3bse013208r1-modulebus-optical-modem-t5d5kfhvioi_0d061849-df46-4de7-9bd4-4c6603e63913.jpg?v=1765532624"},{"product_id":"abb-procontic-t200-gjv3074365r1-07-aa-60-r1-analog-output-module","title":"ABB Procontic T200 GJV3074365R1 07 AA 60 R1  Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e07 AA 60 R1\u003c\/strong\u003e (Order Number: \u003cstrong\u003eGJV3074365R1\u003c\/strong\u003e), frequently referenced in standard inventory directories via its compressed variants \u003cstrong\u003e07AA60R1\u003c\/strong\u003e and \u003cstrong\u003eGJV3074365R1\u003c\/strong\u003e, handles decentralized digital-to-analog signal modulation within the \u003cstrong\u003eABB Procontic T200\u003c\/strong\u003e programmable control infrastructure. This hardware converts localized internal CPU register values into stable, repeatable low-voltage potentials suitable for continuous regulatory tracking and field instrumentation interface tasks.\u003c\/p\u003e\n\u003cp\u003eThe hardware houses \u003cstrong\u003e4 isolated channels\u003c\/strong\u003e that drive standard linear voltage outputs scaling across a \u003cstrong\u003e0 to 10 V\u003c\/strong\u003e instrumentation grid. Operating at an integrated conversion resolution of \u003cstrong\u003e8 bits\u003c\/strong\u003e, the subsystem is constructed with high-integrity electrical isolation, decoupling the field-side analog loop wiring from the centralized subrack processor backplane. This galvanic separation safeguards core system logic against common-mode voltage spikes, ground-fault loop interactions, and inductive noise propagation commonly found across heavy machinery bays and industrial marshaling cabinets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures an isolated configuration managing \u003cstrong\u003e4 analog output channels\u003c\/strong\u003e on a single circuit card footprint.\u003c\/li\u003e\n\u003cli\u003eDrives standard low-voltage analog command loops scaling across a linear \u003cstrong\u003e0 to 10 V\u003c\/strong\u003e signal range.\u003c\/li\u003e\n\u003cli\u003eUtilizes \u003cstrong\u003e8 bits\u003c\/strong\u003e of resolution mapping discrete digital steps into precise field output tracking voltages.\u003c\/li\u003e\n\u003cli\u003eFull \u003cstrong\u003eelectrical isolation\u003c\/strong\u003e protects the internal subrack logic from external field loop disturbances.\u003c\/li\u003e\n\u003cli\u003eSlim slot form factor designed for direct installation into standard \u003cstrong\u003eABB Procontic T200\u003c\/strong\u003e subracks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProportional speed control interfacing with small variable voltage frequency drive modules.\u003c\/li\u003e\n\u003cli\u003eModulating automated control valve positioning circuits and active physical damper positions.\u003c\/li\u003e\n\u003cli\u003eDirect interface links out to basic analog panel indicators, strip-chart monitoring recorders, and remote testing meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCompact Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCompact Order Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e07 AA 60 R1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e07AA60R1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGJV3074365R1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGJV3074365R1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOfficial Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e07 AA 60 R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompact Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e07AA60R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOfficial Order Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJV3074365R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB Procontic T200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (Between field loops and internal system logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Slot Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.5 mm (Standard T200 I\/O module slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Installation Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e165 mm (Mounting depth of typical T200 I\/O units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubrack Slot Alignment\u003c\/strong\u003e: Insert the hardware module into a free, unassigned I\/O card position inside the designated chassis frame. Ensure the guide rails are correctly engaged before seating the front bus connector securely into the system backplane assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation of Signal Classes\u003c\/strong\u003e: Route the low-voltage 0 to 10 V analog signal connections inside independent shielded conduit channels, separated from high-current AC mains feeds or high-frequency relay switching runs to maintain signaling accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Bond Management\u003c\/strong\u003e: Employ twisted-pair shielded instrumentation wires for all field-side connections. Bond the structural cable shield braid to a singular, clean instrumentation earth bar inside the cabinet housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Ventilation Requirements\u003c\/strong\u003e: Ensure the overall mounting array does not exceed standard operating depth guidelines. Maintain open clearance paths below the subrack assembly to allow unhindered vertical convection airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the functional conversion matrix provided by the 8 bits resolution on the 07 AA 60 R1 \/ 07AA60R1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated converter translates a digital code scale from 0 to 255 steps into uniform incremental steps across the 0 to 10 V field output terminal potential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre the individual analog channel circuits isolated from one another on this card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe interface features complete electrical isolation between the collective field circuits and the backplane logic tracks; however, the discrete internal channels typically share a common reference return point on the terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support direct current loop applications like 4 to 20 mA signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this module configuration is constructed specifically to drive linear 0 to 10 V voltage grids. External step-down or converter resistors would be required if current translation is desired.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be inserted or removed from the system chassis while the subrack is actively powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, always completely isolate the primary subrack power supply before removing or inserting any module to prevent backplane bus errors or physical damage to the contact array.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668517319019,"sku":"GJV3074365R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-07aa60r1-gjv3074365r1-output-module-plo5sp2nhyf_ceb31e9c-f1bf-4b25-b14e-9b6686aaf7dc.jpg?v=1765532711"},{"product_id":"abb-gjr5251600r0202-07ai91-ac31-analog-input-module","title":"ABB GJR5251600R0202 07AI91 AC31 Analog Input Module","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eAn analog input module designed for remote data acquisition on the CS31 system bus within ABB AC31 automation systems. The \u003cstrong\u003eABB 07 AI 91\u003c\/strong\u003e module, also referenced as \u003cstrong\u003e07AI91\u003c\/strong\u003e, provides eight configurable analog input channels for voltage, current, temperature sensor, and thermocouple measurement applications. The order number \u003cstrong\u003eGJR5 2516 00 R0202\u003c\/strong\u003e is also commonly referenced in maintenance databases and procurement systems as \u003cstrong\u003eGJR5251600R0202\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe module supports configurable measurement ranges including +\/-10 V, +\/-5 V, +\/-500 mV, +\/-50 mV, 4...20 mA, Pt100, Pt1000, and thermocouple types J, K, and S with linearization. Channel configuration is performed in pairs using DIL switches located beneath the housing cover.\u003cbr\u003eCommunication with the controller is performed through the electrically isolated CS31 system bus using the EIA RS-485 transmission standard. The module incorporates self-calibration functions, diagnostic monitoring, open-circuit detection, transmission error detection, and local LED status indication.\u003cbr\u003eThe module is suitable for process monitoring, temperature measurement systems, industrial instrumentation, utility automation, machine control systems, and distributed analog signal acquisition applications requiring high-resolution analog input processing.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 configurable analog input channels\u003c\/li\u003e\n\u003cli\u003eCS31 system bus communication\u003c\/li\u003e\n\u003cli\u003eEIA RS-485 interface standard\u003c\/li\u003e\n\u003cli\u003e12-bit resolution with sign\u003c\/li\u003e\n\u003cli\u003eSupports voltage, current, RTD and thermocouple inputs\u003c\/li\u003e\n\u003cli\u003ePt100 and Pt1000 linearization\u003c\/li\u003e\n\u003cli\u003eThermocouple types J, K and S linearization\u003c\/li\u003e\n\u003cli\u003eConfigurable 50 Hz or 60 Hz line frequency suppression\u003c\/li\u003e\n\u003cli\u003eOpen-circuit detection\u003c\/li\u003e\n\u003cli\u003eRange exceed detection\u003c\/li\u003e\n\u003cli\u003eInternal self-calibration function\u003c\/li\u003e\n\u003cli\u003eElectrically isolated CS31 bus interface\u003c\/li\u003e\n\u003cli\u003e17 LED diagnostic and status indicators\u003c\/li\u003e\n\u003cli\u003eDIL-switch configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess instrumentation systems\u003c\/li\u003e\n\u003cli\u003eTemperature monitoring applications\u003c\/li\u003e\n\u003cli\u003eIndustrial furnace control systems\u003c\/li\u003e\n\u003cli\u003eUtility and infrastructure automation\u003c\/li\u003e\n\u003cli\u003eWater and wastewater facilities\u003c\/li\u003e\n\u003cli\u003eMachine condition monitoring\u003c\/li\u003e\n\u003cli\u003eDistributed analog signal acquisition\u003c\/li\u003e\n\u003cli\u003eManufacturing process control\u003c\/li\u003e\n\u003cli\u003eEnergy management systems\u003c\/li\u003e\n\u003cli\u003eSensor interface applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eOrder Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e07 AI 91 Analog Input Module\u003c\/td\u003e\n\u003ctd\u003eGJR5 2516 00 R0202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e07 AI 91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate Model\u003c\/td\u003e\n\u003ctd\u003e07AI91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number\u003c\/td\u003e\n\u003ctd\u003eGJR5 2516 00 R0202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate Part Number\u003c\/td\u003e\n\u003ctd\u003eGJR5251600R0202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAC31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Bus\u003c\/td\u003e\n\u003ctd\u003eCS31 System Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Standard\u003c\/td\u003e\n\u003ctd\u003eEIA RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bit + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Overvoltage\u003c\/td\u003e\n\u003ctd\u003eMax. +\/-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Voltage)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency Suppression\u003c\/td\u003e\n\u003ctd\u003e50 Hz, 60 Hz or none\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time (50\/60 Hz suppression)\u003c\/td\u003e\n\u003ctd\u003eTypical 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time (No suppression)\u003c\/td\u003e\n\u003ctd\u003eTypical 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time (Thermocouples)\u003c\/td\u003e\n\u003ctd\u003eTypical 150 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eCS31 bus interface isolated from module electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e450 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSupported Input Types\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal Type\u003c\/th\u003e\n\u003cth\u003eMeasurement Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input\u003c\/td\u003e\n\u003ctd\u003e+\/-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input\u003c\/td\u003e\n\u003ctd\u003e+\/-500 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input\u003c\/td\u003e\n\u003ctd\u003e+\/-50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input\u003c\/td\u003e\n\u003ctd\u003e4...20 mA (external 250 Ohm resistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input\u003c\/td\u003e\n\u003ctd\u003e0...20 mA via +\/-5 V range and external 250 Ohm resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input\u003c\/td\u003e\n\u003ctd\u003ePt100 with linearization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input\u003c\/td\u003e\n\u003ctd\u003ePt1000 with linearization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple\u003c\/td\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple\u003c\/td\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple\u003c\/td\u003e\n\u003ctd\u003eType S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTemperature Measurement Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePt100 Range\u003c\/td\u003e\n\u003ctd\u003e-50 to +400 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePt1000 Range\u003c\/td\u003e\n\u003ctd\u003e-50 to +400 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple J Range\u003c\/td\u003e\n\u003ctd\u003e0 to +1200 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple K Range\u003c\/td\u003e\n\u003ctd\u003e0 to +1372 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple S Range\u003c\/td\u003e\n\u003ctd\u003e0 to +1600 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Resolution\u003c\/td\u003e\n\u003ctd\u003e1 LSB = 0.4 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvaluation Error\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCS31 System Bus\u003c\/td\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL+\u003c\/td\u003e\n\u003ctd\u003e24 V DC Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM\u003c\/td\u003e\n\u003ctd\u003e0 V Supply Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAGND\u003c\/td\u003e\n\u003ctd\u003eAnalog Ground Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEA00-EA07\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHIELD\u003c\/td\u003e\n\u003ctd\u003eCable Shield Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall vertically with terminals facing upward and downward.\u003c\/li\u003e\n\u003cli\u003eMount on DIN EN 50022-35 rail or secure using four M4 screws.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for analog signal wiring.\u003c\/li\u003e\n\u003cli\u003eGround cable shields at the cabinet entry point.\u003c\/li\u003e\n\u003cli\u003eEnsure all temperature and voltage sensors are electrically isolated from their mounting environment.\u003c\/li\u003e\n\u003cli\u003eBridge unused input channels according to sensor type requirements.\u003c\/li\u003e\n\u003cli\u003eConfigure measurement ranges using the onboard DIL switches before commissioning.\u003c\/li\u003e\n\u003cli\u003eMaintain unobstructed airflow around the module for natural convection cooling.\u003c\/li\u003e\n\u003cli\u003eIntegrate the process power supply grounding into the overall control system grounding concept.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs 07AI91 the same module as 07 AI 91?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. 07AI91 is a compact reference format frequently used in ERP systems and spare-parts databases for the same module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs GJR5251600R0202 equivalent to GJR5 2516 00 R0202?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Both part number formats identify the same ABB analog input module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich temperature sensors can be connected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports Pt100, Pt1000, and thermocouple types J, K, and S with integrated linearization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat analog signal ranges are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfigurable ranges include +\/-10 V, +\/-5 V, +\/-500 mV, +\/-50 mV, and 4...20 mA using an external 250 Ohm resistor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat diagnostic functions are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides open-circuit detection, range exceed monitoring, internal module diagnostics, transmission error detection, and self-calibration functions.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668527116651,"sku":"07AI91 GJR5251600R0202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-07ai91-gjr5251600r0202-analog-i-o-module-1lvzyasxpcy_c9719236-f7db-4223-bfe9-c386e18b7081.jpg?v=1765532841"},{"product_id":"abb-tb806-3bse008536r1-s800-i-o-modulebus-bus-inlet","title":"ABB TB806 3BSE008536R1 S800 I\/O Modulebus Bus Inlet","description":"\u003cp\u003eThe \u003cstrong\u003eTB806\u003c\/strong\u003e with part number \u003cstrong\u003e3BSE008536R1\u003c\/strong\u003e is a specialized Modulebus bus inlet adapter designed to facilitate physical bus expansion within the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e hardware architecture. It features a male D-sub 25-pin connector housing that acts as the hardware bridge to interface standard internal bus signaling with extended field configurations. Exactly one adapter unit is required to properly terminate and connect each \u003cstrong\u003eTK801\u003c\/strong\u003e Modulebus extension cable assembly. This component guarantees the maintenance of continuous, low-impedance connection profiles for control bus lines bridging separate chassis segments across System 800xA, Advant OCS, or Compact Product Suite networks.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTB806\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e3BSE008536R1: Modulebus Extension Cable Adaptor D-sub 25, Male\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTB806\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE008536R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD-sub 25, male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires 1 pcs per TK801 extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O, System 800xA (Versions 4.0, 4.1, 5.0, 5.1, 6.0), Advant OCS with Master SW, Advant Fieldbus 100, Advant OCS with MOD 300 SW, Compact Product Suite (Versions 4.1, 5.0, 5.1, 6.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e853690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85369095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.046 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulebus Segments Integration\u003c\/strong\u003e: The bus inlet serves as a critical connection link for adding distance or shifting layouts via cables between distributed rail segments without causing protocol transmission timing issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatching Cable Requirements\u003c\/strong\u003e: System planning matrices must allocate precisely one inlet plug for every individual TK801 extension cable run deployed in the topology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassive Electrical Interface\u003c\/strong\u003e: As a non-powered, mechanical-electrical adaptation interface, this module carries no active firmware or logic properties, minimizing component wear vectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Footprint Deployment\u003c\/strong\u003e: The minimal physical envelope allows clean, space-saving mounting paths inside restricted junction boxes or congested system panel rails.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Alignment\u003c\/strong\u003e: Align the D-sub 25-pin male connection pattern squarely over the receptacle port before applying force, avoiding skewed paths that bent or crushed pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Strain Relief\u003c\/strong\u003e: Anchor adjacent TK801 cables to a structural support rail or bracket to prevent localized terminal pull forces from causing intermittent bus open-faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic Charge Control\u003c\/strong\u003e: Ensure the field technician is thoroughly grounded using an standard industrial ESD wrist strap during handling and seating phases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Environment Sealing\u003c\/strong\u003e: Keep the connector free from dust, corrosive airborne chemical compounds, and localized moisture tracking to preserve stable contact interface resistances.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668584198507,"sku":"TB806 3BSE008536R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tb806-3bse008536r1-modulebus-extension-cable-adaptor-254v0dndczj_06ef793e-b839-4eb9-934a-b7b868b46030.jpg?v=1765532989"},{"product_id":"abb-07ac91-gjr5252300r0101-advant-controller-31-analog-i-o-module","title":"ABB 07AC91 GJR5252300R0101 Advant Controller 31 Analog I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e07 AC 91\u003c\/strong\u003e (Order Number: \u003cstrong\u003eGJR5 2523 00 R0101\u003c\/strong\u003e), also widely searched under the compact model designations \u003cstrong\u003e07AC91\u003c\/strong\u003e and \u003cstrong\u003eGJR5252300R0101\u003c\/strong\u003e, functions as a combined multichannel analog processing interface for the \u003cstrong\u003eAdvant Controller 31\u003c\/strong\u003e (AC31) automation core. This hardware enables simultaneous acquisition of high-resolution field telemetry alongside continuous control output signal modulation over localized regulatory loops.\u003c\/p\u003e\n\u003cp\u003eOperating across a dedicated \u003cstrong\u003eCS31 system bus\u003c\/strong\u003e architecture using physical \u003cstrong\u003eEIA RS-485\u003c\/strong\u003e signaling properties, the hardware coordinates either \u003cstrong\u003e8 or 16 channels\u003c\/strong\u003e depending on the selected operating resolution mode (12-bit or 8-bit). A unique feature is the inclusion of integrated \u003cstrong\u003eself-protecting current shunts\u003c\/strong\u003e that monitor current loops and systematically drop field overloads to prevent hardware circuit damage. Additionally, an external \u003cstrong\u003ebinary enabling input\u003c\/strong\u003e acts as a hardwired safety interlock, ensuring all associated analog output channels collapse immediately to zero if the driving interlock signal drops out.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdaptable architecture processing either \u003cstrong\u003e8 channels under 12-bit operating mode\u003c\/strong\u003e or up to \u003cstrong\u003e16 channels under 8-bit operating mode\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIndividual channel software selection in 12-bit operation accommodating \u003cstrong\u003eplus or minus 10 V ranges\u003c\/strong\u003e or \u003cstrong\u003e0 to 20 mA current loops\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIntegrates an independent hardware-level \u003cstrong\u003ebinary enabling input (24V)\u003c\/strong\u003e mandatory for active execution of the analog output stages.\u003c\/li\u003e\n\u003cli\u003eCurrent input nodes incorporate built-in \u003cstrong\u003eself-protecting shunts\u003c\/strong\u003e with 1-second auto-recovery sampling increments during overcurrent faults.\u003c\/li\u003e\n\u003cli\u003ePopulates a localized visual monitoring interface consisting of \u003cstrong\u003e17 diagnostic LEDs\u003c\/strong\u003e for field loop and status reporting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-point continuous feedback and actuator control loops within wastewater facilities, printing plant machinery, and processing infrastructure.\u003c\/li\u003e\n\u003cli\u003eDistributed analog signal marshaling and diagnostic multiplexing back to a central \u003cstrong\u003eAdvant Controller 31\u003c\/strong\u003e processing hub.\u003c\/li\u003e\n\u003cli\u003eFailsafe control of proportional dosing pumps and variable frequency drive arrays requiring separate hardware interlock authorization loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCompact Order Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eScope of Delivery\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGJR5 2523 00 R0101\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGJR5252300R0101\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e07 AC 91 (07AC91)\u003c\/td\u003e\n\u003ctd\u003e1x Analog input and output module, 1x 2-pole terminal block (3.81 mm grid), 1x 3-pole terminal block (5.08 mm grid), 1x 5-pole terminal block (5.08 mm grid), 4x 8-pole terminal blocks (3.81 mm grid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOfficial Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e07 AC 91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompact Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e07AC91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOfficial Order Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJR5 2523 00 R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompact Order Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJR5252300R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvant Controller 31 \/ AC31 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input and Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReversed Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (For primary power connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Binary Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 (Enabling input for analog outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Analog Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 or 16 channels (Dependent on selected operating mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Communication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCS31 System Bus via EIA RS-485 Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCS31 bus from unit, 1 binary input from unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddress Setup Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual coding switch located under right side housing cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Error Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypical 0.5 %, Maximum 1 % (Non-linearity, resolution and factory calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Potential Difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 V (Between supply terminal M and analog ground AGND)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Reference Potential\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAGND (Minus terminal of all analog inputs and outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Cable Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 100 m (Two-core shielded, cross section \u0026gt; 0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Filter Time Constants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470 us for voltage inputs, 100 us for current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Cycle (8 In + 8 Out)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Ohmic Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage input: \u0026gt; 100 kOhm, Current input: Approx. 330 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Output Loading\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax +20 mA (Source), Max -10 mA (Sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Output Load Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Ohm (Burden)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Mounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail (DIN EN 50022-35, 15 mm deep) or via 4x M4 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth x Height x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 140 x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Terminal Block Class\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Options\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eApplicable Termination Mapping\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Screw-Type Terminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 1 x 2.5 mm2 or Max 2 x 1.5 mm2\u003c\/td\u003e\n\u003ctd\u003ePrimary 24V DC Supply Terminals, CS31 System Bus Pins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Screw-Type Terminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 1 x 1.5 mm2\u003c\/td\u003e\n\u003ctd\u003eAll Analog Inputs, Analog Outputs, and Enabling Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 25 (+) and Terminal 26 (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-Wire Binary Interlock Loop\u003c\/td\u003e\n\u003ctd\u003eDedicated Analog Output Enabling Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnabling Voltage Signal Routing\u003c\/strong\u003e: Wire a permanent 1 signal (+13 to +30 V) across terminals 25 (+) and 26 (-) to permit output activation. A 0 signal (-30 to +5 V) forces voltage loops to 0 V and current loops to 0 mA automatically.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Mitigation for Unused Inputs\u003c\/strong\u003e: Bridge all unused voltage input terminals directly to improve overall field noise immunity. Unused current inputs maintain low internal impedance properties and can safely remain open.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Ventilation Alignment\u003c\/strong\u003e: Affix the housing exclusively in a vertical position inside the panel layout, ensuring all terminal connectors point straight up and down. Maintain clear spacing above and below to prevent obstruction of natural convection cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Continuity Policies\u003c\/strong\u003e: Limit field analog runs to a maximum of 100 m using two-core shielded cable above 0.5 mm2, grounding the shields at a single clean instrumentation earth point.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are network station addresses configured on the 07 AC 91 \/ 07AC91 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe field identification address and operating mode parameters are adjusted using a manual hardware coding switch block positioned underneath the protective plastic clip cover on the right side of the module housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the functional response of the current loop if a field instrument encounters a short-circuit fault?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module has an embedded self-protecting current feature. If loop currents spike beyond safe thresholds, the internal measuring shunt is cut off and records an overflow value. The unit tests the line every 1 second, restoring normal tracking once the current falls within limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs there individual electrical isolation between the discrete analog signal lines?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, all input and output channels are non-isolated from one another and share a common electrical node designated as AGND. The CS31 bus interface and the single binary input are, however, fully isolated from the remaining internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are signal values mapped inside the controller application logic during 12-bit operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe full scale scale from -100% to +100% relates directly to hex codes ranging from 8008H through 0000H up to 7FF8H, which corresponds to decimal integers -32760 to 32760.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668584853867,"sku":"07AC91 GJR5252300R0101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-07ac91-gjr5252300r0101-analog-i-o-module-ftdn24ik0mq_79e1f787-26dd-4e74-a80e-9dbed9110728.jpg?v=1765533011"},{"product_id":"abb-tu843-3bse021443r1-s800-i-o-redundant-module-termination-unit","title":"ABB TU843 3BSE021443R1 S800 I\/O Redundant Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU843\u003c\/strong\u003e is a specialized \u003cstrong\u003eModule Termination Unit (MTU)\u003c\/strong\u003e engineered for integration with \u003cstrong\u003eredundant I\/O\u003c\/strong\u003e modules within the \u003cstrong\u003eABB S800 I\/O\u003c\/strong\u003e ecosystem. It acts as the mechanical and electrical anchoring base for dual I\/O modules, establishing a robust interface that enables hot-swapping and seamless failover configurations in critical industrial processes. The base facilitates all field wiring connections and internal ModuleBus pass-through channels without breaking signal continuity during servicing.\u003c\/p\u003e\n\u003cp\u003eThis specific unit is configured for \u003cstrong\u003evertical DIN rail mounting\u003c\/strong\u003e, allowing control engineers to optimize cabinet layout and high-density tracking. Functioning safely within a low-voltage spectrum up to \u003cstrong\u003e50V\u003c\/strong\u003e, the unit manages discrete, analog, and communication loop distribution lines across automated control infrastructures managed by broader decentralized control networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt exclusively to house dual redundant S800 I\/O modules\u003c\/li\u003e\n\u003cli\u003eVertical DIN rail mounting topology for specific cabinet orientations\u003c\/li\u003e\n\u003cli\u003eSimplifies field signal routing via built-in terminal blocks\u003c\/li\u003e\n\u003cli\u003eSupports hot-swapping of inactive or faulted modules under power\u003c\/li\u003e\n\u003cli\u003eVerified operational threshold up to 50V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) deployments featuring ABB System 800xA\u003c\/li\u003e\n\u003cli\u003eCompact Product Suite automation setups requiring space-saving form factors\u003c\/li\u003e\n\u003cli\u003eHigh-availability process loops in petrochemical, marine, and power facilities\u003c\/li\u003e\n\u003cli\u003eMission-critical safety or auxiliary monitoring stations requiring redundant failover paths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\/Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU843\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE021443R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule_Termination_Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Redundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSCIP Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7c710169-c950-4bd8-ae0c-d8dba80a0de2 Bulgaria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Snap the assembly firmly onto a standard 35mm vertical DIN rail. Ensure the rail is bonded to the main enclosure earth ground system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Orientation\u003c\/strong\u003e: Verify the mounting orientation matches the vertical layout requirement to satisfy default convective airflow pathways around operational modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Practice\u003c\/strong\u003e: Terminate field cables utilizing proper wire ferrule dimensions, taking care to segregate low-voltage instrument loops from adjacent higher-voltage power distribution runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Handling\u003c\/strong\u003e: When inserting or extracting an I\/O module from either slot, use even pressure to avoid skewing the multipin backplane connection pins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core difference between the TU842 and the TU843 termination units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe primary difference is the physical mounting layout. The TU842 is configured for horizontal DIN rail mounting, whereas this unit is structurally designed for vertical DIN rail installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this MTU require an isolated external grounding strap?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device grounds through its DIN rail attachment, though following standard cabinet grounding practices by maintaining a low-impedance connection to the main backplate is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I run standard 120V AC control loops directly through this termination block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this termination unit has a maximum rated technical voltage of 50V. Exceeding this limit compromises the safety and operational constraints of the device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there internal batteries that require scheduling for maintenance replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this passive termination unit contains zero batteries and relies entirely on external system bus architectures for operational logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat versions of the ABB 800xA control platform are compatible with this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is cataloged for compatibility with S800 I\/O versions 4.0, 4.1, 5.0, 5.1, and System 800xA 6.0 setups.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668610511211,"sku":"3BSE021443R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu843-3bse021443r1-compact-product-suite-hardware-selector-yrnn1ujdza1_0bca439e-cd83-4bf3-99f3-a0742d437c85.jpg?v=1765535473"},{"product_id":"abb-tu842-3bse020850r1-s800-i-o-redundant-module-termination-unit","title":"ABB TU842 3BSE020850R1 S800 I\/O Redundant Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU842\u003c\/strong\u003e is a \u003cstrong\u003eModule Termination Unit\u003c\/strong\u003e (MTU) designed for the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e system to support \u003cstrong\u003eredundant I\/O\u003c\/strong\u003e configurations. It serves as the physical and electrical interface base, enabling two compatible S800 I\/O modules to work in pairs for high-availability process automation applications. Engineered with a maximum voltage rating of \u003cstrong\u003e50V\u003c\/strong\u003e, this unit routes signal and power lines safely while facilitating \u003cstrong\u003ehorizontal DIN rail mounting\u003c\/strong\u003e inside electrical control cabinets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt for redundant I\/O module pairing to eliminate single points of failure.\u003c\/li\u003e\n\u003cli\u003eRated for signal and power distribution up to 50V maximum.\u003c\/li\u003e\n\u003cli\u003eFormed for horizontal mounting orientation on standard industrial DIN rails.\u003c\/li\u003e\n\u003cli\u003eStreamlines field wiring termination to improve system maintainability.\u003c\/li\u003e\n\u003cli\u003eIntegrated keying mechanisms prevent the accidental insertion of mismatched I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) requiring high-availability configurations.\u003c\/li\u003e\n\u003cli\u003eCritical process loops in chemical plants, oil refineries, and water treatment utilities.\u003c\/li\u003e\n\u003cli\u003ePower generation plant safety and auxiliary control setups.\u003c\/li\u003e\n\u003cli\u003eFactory automation control systems utilizing the S800 I\/O architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU842\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE020850R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O System (System 800xA 4.0\/4.1\/5.0\/5.1\/6.0, Compact Product Suite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundant I\/O support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eDIN Rail Mounting\u003c\/h3\u003e\n\u003cp\u003eMount the unit horizontally on a top-hat standard 35 mm DIN rail. Ensure the rail is grounded properly to the backplate of the enclosure to manage electromagnetic interference. Snap the locking clips securely onto the rail to avoid movement under vibration.\u003c\/p\u003e\n\u003ch3\u003eWiring and Signal Insulation\u003c\/h3\u003e\n\u003cp\u003eVerify that all field wiring routed to the terminal connections does not exceed the maximum specification of 50V. Maintain proper separation between low-voltage signal cables and high-power electrical runs within the cable ducting.\u003c\/p\u003e\n\u003ch3\u003eRedundant Module Matching\u003c\/h3\u003e\n\u003cp\u003eWhen seating modules into the dual slots of the base unit, ensure that both components are of identical model numbers and firmware revisions to maintain proper synchronization and failover functions.\u003c\/p\u003e\n\u003ch3\u003eHeat Dissipation\u003c\/h3\u003e\n\u003cp\u003eKeep appropriate open space above and below the horizontally installed base unit. Proper spacing prevents stagnant hot air pockets and guarantees sufficient natural convection across the module housings.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core purpose of the TU842 base unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides the shared electrical connection points and mechanical mounting slots required to operate two S800 I\/O modules in a redundant configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum operational voltage supported by this termination unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is specified for a maximum operating voltage of 50V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be mounted vertically on the DIN rail?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this module termination unit is explicitly designed for horizontal DIN rail mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this product incorporate any batteries?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the unit contains zero batteries and depends entirely on external system power distribution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich ABB control architectures support this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is fully compatible with ABB System 800xA versions 4.0 through 6.0 and the Compact Product Suite running S800 I\/O modules.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668610871659,"sku":"3BSE020850R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu842-3bse020850r1-redundant-module-termination-unit-5vorksgfbzz_39676cee-c90a-47a9-b5a3-6ee7289098f7.jpg?v=1765535487"},{"product_id":"abb-1sap417000r0001-tu532-xc-s500-i-o-terminal-unit","title":"ABB 1SAP417000R0001 TU532-XC S500 I\/O Terminal Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU532-XC\u003c\/strong\u003e is an S500 distributed I\/O terminal unit designed for use with 230 VAC and relay modules in ABB AC500-XC automation systems. It provides spring terminal connectivity for industrial wiring applications operating under extended environmental conditions.\u003c\/p\u003e\n\u003cp\u003eThe unit supports secure field wiring connections for distributed automation architectures and is intended for integration within ABB S500-XC I\/O systems. Its compact construction allows efficient DIN rail installation inside industrial control cabinets while maintaining reliable signal and power distribution for compatible modules.\u003c\/p\u003e\n\u003cp\u003eDesigned for harsh industrial environments, the \u003cstrong\u003e1SAP417000R0001\u003c\/strong\u003e terminal unit operates across a wide ambient temperature range and supports installation in demanding automation applications requiring extended environmental tolerance.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU532-XC\u003c\/strong\u003e is compatible with ABB AC500-XC programmable logic controller systems and associated S500-XC relay and 230 VAC I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpring terminal connection technology\u003c\/li\u003e\n\u003cli\u003eDesigned for 230 VAC and relay modules\u003c\/li\u003e\n\u003cli\u003eCompatible with ABB S500-XC distributed I\/O systems\u003c\/li\u003e\n\u003cli\u003eSupports AC500-XC PLC environments\u003c\/li\u003e\n\u003cli\u003eCompact DIN rail mounting format\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating\u003c\/li\u003e\n\u003cli\u003eExtended operating temperature range\u003c\/li\u003e\n\u003cli\u003eIndustrial cabinet installation design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePLC control cabinets\u003c\/li\u003e\n\u003cli\u003eDistributed automation systems\u003c\/li\u003e\n\u003cli\u003eIndustrial process control\u003c\/li\u003e\n\u003cli\u003eFactory automation systems\u003c\/li\u003e\n\u003cli\u003ePower and utility automation\u003c\/li\u003e\n\u003cli\u003eHarsh environment installations\u003c\/li\u003e\n\u003cli\u003eMachine control systems\u003c\/li\u003e\n\u003cli\u003eRemote I\/O assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTU532-XC: S500 I\/O terminal unit\u003c\/li\u003e\n\u003cli\u003e1SAP417000R0001: Product ID\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e1SAP417000R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTU532-XC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS500-XC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eDistributed Automation I\/Os\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eFor 230 VAC and relay modules. Spring terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eSpring terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30...+70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40...+85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width\u003c\/td\u003e\n\u003ctd\u003e67.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height\u003c\/td\u003e\n\u003ctd\u003e135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Depth\u003c\/td\u003e\n\u003ctd\u003e28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.165 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e0.195 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelling Unit\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4016779846394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETIM 8\u003c\/td\u003e\n\u003ctd\u003eEC000810 - PLC mounting rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUNSPSC\u003c\/td\u003e\n\u003ctd\u003e32151703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the terminal unit on a properly grounded DIN rail inside an industrial control enclosure. Maintain adequate spacing for ventilation and cable routing. Use suitable wire ferrules for spring terminal connections where required by local installation practices.\u003c\/p\u003e\n\u003cp\u003eSeparate high-voltage wiring from low-level signal cables to reduce electromagnetic interference. Ensure cabinet protection against moisture, dust, and vibration according to the environmental requirements of the installation site.\u003c\/p\u003e\n\u003cp\u003eVerify compatibility with corresponding S500-XC relay and 230 VAC modules before system energization.\u003c\/p\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEU \u0026amp; UK Declaration of Conformity - S500 relay modules\u003c\/li\u003e\n\u003cli\u003eREACH declaration ABB PLC products\u003c\/li\u003e\n\u003cli\u003eRoHS compliance according to EU Directive 2011\/65\/EU and Amendment 2015\/863\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the TU532-XC?\u003c\/strong\u003e\u003cbr\u003eIt provides terminal wiring connections for ABB S500-XC 230 VAC and relay modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich PLC platform supports this terminal unit?\u003c\/strong\u003e\u003cbr\u003eIt is used within ABB AC500-XC automation systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of terminals are used?\u003c\/strong\u003e\u003cbr\u003eThe unit uses spring terminal connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the unit operate in harsh environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for eXtreme Conditions applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the protection rating?\u003c\/strong\u003e\u003cbr\u003eThe enclosure protection rating is IP20.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module suitable for DIN rail installation?\u003c\/strong\u003e\u003cbr\u003eYes. The design supports standard control cabinet DIN rail mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eThe specified operating range is -30 to +70 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat modules are compatible with this unit?\u003c\/strong\u003e\u003cbr\u003eIt is intended for 230 VAC and relay modules within the S500-XC series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the unit include communication interfaces?\u003c\/strong\u003e\u003cbr\u003eNo communication interface information is specified for this terminal unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the storage temperature limit?\u003c\/strong\u003e\u003cbr\u003eThe storage range is -40 to +85 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the product RoHS compliant?\u003c\/strong\u003e\u003cbr\u003eYes. ABB specifies compliance with EU RoHS requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the product weight?\u003c\/strong\u003e\u003cbr\u003eThe net weight is 0.165 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the unit be used in distributed I\/O systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is part of ABB distributed automation I\/O architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cabinet environment is recommended?\u003c\/strong\u003e\u003cbr\u003eInstallation inside protected industrial control panels is recommended.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668611428715,"sku":"TU532-XC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu532-xc-1sap417000r0001-i-o-terminal-unit-m04svh0rxui_2be8e0f8-473f-4e69-931f-85b2626b7f36.jpg?v=1765535508"},{"product_id":"abb-tu811v1-3bse013231r1-s800-i-o-compact-module-termination-unit","title":"ABB TU811V1 3BSE013231R1 S800 I\/O Compact Module Termination Unit","description":"\u003cp style=\"font-size: 14px; color: #2d3748; line-height: 1.6; margin-top: 0; margin-bottom: 20px;\"\u003e\n  The ABB TU811V1 is a compact module termination unit engineered for the \u003cstrong\u003eS800 I\/O system\u003c\/strong\u003e platform to manage field signaling pathways within distributed control architectures. This industrial interface component facilitates point-to-point electrical links, utilizing a \u003cstrong\u003e1x8 signal terminal configuration\u003c\/strong\u003e rated for operating limits up to \u003cstrong\u003e250V\u003c\/strong\u003e. Designated by the product ID (ordering number) \u003cstrong\u003e3BSE013231R1\u003c\/strong\u003e and Type Designation \u003cstrong\u003eTU811V1\u003c\/strong\u003e, this compact hardware base routes passive or active field signals safely into processing modules across continuous manufacturing plants. Constructed without internal batteries, its low-clearance design enables high-density sub-rack integration, preventing complex wiring faults, shielding data links against electromagnetic grid interference, and stabilizing industrial data synchronization.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; font-size: 18px; border-bottom: 2px solid #e2e8f0; padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 20px; padding-left: 20px; list-style-type: square; font-size: 14px; color: #2d3748; line-height: 1.6;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eCompact hardware layout featuring a focused 1x8 signal terminal group for clean field conductor routing.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eHigh-voltage circuit configuration officially rated up to a maximum distribution limit of 250V.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eBattery-free component design reducing preventive maintenance tracking and field replacement tasks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eCompliance with RoHS European Directive 2011\/65\/EU and classified under small equipment guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; font-size: 18px; border-bottom: 2px solid #e2e8f0; padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 20px; padding-left: 20px; list-style-type: square; font-size: 14px; color: #2d3748; line-height: 1.6;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eS800 I\/O and System 800xA distributed control nodes handling multi-channel field automation loops.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eAdvant OCS with Master SW or MOD 300 SW fieldbus interface arrangements.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eCompact Product Suite field environments requiring isolated, high-density terminal configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; font-size: 18px; border-bottom: 2px solid #e2e8f0; padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 25px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color: #f7fafc; border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d; border: 1px solid #e2e8f0; width: 40%;\"\u003eOrdering Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d; border: 1px solid #e2e8f0; width: 60%;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eProduct ID (Ordering Number)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e3BSE013231R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eABB Type Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eTU811V1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eCustoms Tariff Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e85371098\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eHS Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e853710 - Boards, panels, consoles, desks, cabinets for electric control (voltage not exceeding 11000 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; font-size: 18px; border-bottom: 2px solid #e2e8f0; padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 25px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color: #f7fafc; border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d; border: 1px solid #e2e8f0; width: 40%;\"\u003eTechnical Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d; border: 1px solid #e2e8f0; width: 60%;\"\u003eSpecification Data\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eModule Termination Unit (MTU)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eTerminal Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e1x8 Signal Terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eVoltage Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e250V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eProduct Net Width\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e58.5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eProduct Net Height\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e170 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e64 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eProduct Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0.2 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eNumber of Batteries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eRoHS Environmental Profile\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eWEEE Equipment Category\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eSVHC Presence\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eNo SVHC present (Bulgaria)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eSweden\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0.35 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e190 mm x 85 mm x 75 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; font-size: 18px; border-bottom: 2px solid #e2e8f0; padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #2d3748; margin-bottom: 20px; line-height: 1.6;\"\u003e\n  To prevent erratic processing loops or instantaneous voltage damage to coupled S800 I\/O modules, adhere to specific industrial execution sequences.\n\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #e53e3e; padding: 12px 15px; margin-bottom: 20px; border-radius: 0 4px 4px 0;\"\u003e\n  \u003cdiv style=\"color: #c53030; font-weight: bold; margin-bottom: 5px; font-size: 13px; letter-spacing: 0.5px;\"\u003e\n    CRITICAL WARNING: ENERGY ISOLATION REQUIRED\n  \u003c\/div\u003e\n  \u003cdiv style=\"font-size: 13px; color: #742a2a; line-height: 1.5;\"\u003e\n    Verify that all incoming supply lines, field instrumentation loops, and auxiliary power grids connected to the backplane are fully disconnected before beginning assembly manipulation. Handling unit components on an active chassis can result in high transient arcing or physical plant damage.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin: 20px 0;\"\u003e\n  \u003cdiv style=\"position: relative; padding-left: 35px; margin-bottom: 15px;\"\u003e\n    \u003cdiv style=\"position: absolute; left: 0; top: 2px; background-color: #2b6cb0; color: #ffffff; width: 22px; height: 22px; border-radius: 50%; text-align: center; font-size: 12px; font-weight: bold; line-height: 22px;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"font-size: 14px; line-height: 1.5;\"\u003e\n      \u003cdiv style=\"font-weight: bold; color: #1a365d; margin-bottom: 3px;\"\u003eVerify plant lockout conditions\u003c\/div\u003e\n      \u003cdiv style=\"color: #2d3748; font-size: 13px;\"\u003eConfirm that target terminal racks are unpowered and use a calibrated testing instrument to verify a zero-energy state before mounting the assembly.\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"position: relative; padding-left: 35px; margin-bottom: 15px;\"\u003e\n    \u003cdiv style=\"position: absolute; left: 0; top: 2px; background-color: #2b6cb0; color: #ffffff; width: 22px; height: 22px; border-radius: 50%; text-align: center; font-size: 12px; font-weight: bold; line-height: 22px;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"font-size: 14px; line-height: 1.5;\"\u003e\n      \u003cdiv style=\"font-weight: bold; color: #1a365d; margin-bottom: 3px;\"\u003eSecure hardware base to standard DIN rail\u003c\/div\u003e\n      \u003cdiv style=\"color: #2d3748; font-size: 13px;\"\u003eAlign the rear mounting channels with the sub-rack DIN rail and apply downward force until the mechanical ground clips click firmly onto the metallic trace.\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"position: relative; padding-left: 35px; margin-bottom: 15px;\"\u003e\n    \u003cdiv style=\"position: absolute; left: 0; top: 2px; background-color: #2b6cb0; color: #ffffff; width: 22px; height: 22px; border-radius: 50%; text-align: center; font-size: 12px; font-weight: bold; line-height: 22px;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"font-size: 14px; line-height: 1.5;\"\u003e\n      \u003cdiv style=\"font-weight: bold; color: #1a365d; margin-bottom: 3px;\"\u003eLand field conductors into terminal rows\u003c\/div\u003e\n      \u003cdiv style=\"color: #2d3748; font-size: 13px;\"\u003eStrip field signal wires to exact specification lengths, insert them sequentially into the 1x8 terminal blocks, and lock the terminal retention clamps.\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668613656939,"sku":"TU811V1 3BSE013231R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu811v1-3bse013231r1-process-automation-module-0jopisj0p2w_dfad0978-5e61-48a8-b70a-dce49ff14e6c.jpg?v=1765535584"},{"product_id":"abb-tu818-3bse069209r1-s800-i-o-compact-module-termination-unit","title":"ABB TU818 3BSE069209R1 S800 I\/O Compact Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU818\u003c\/strong\u003e (\u003cstrong\u003e3BSE069209R1\u003c\/strong\u003e) is an \u003cstrong\u003eOriginal New\u003c\/strong\u003e compact module termination unit (MTU) designed for the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e distributed hardware platform by \u003cstrong\u003eABB\u003c\/strong\u003e. This passive base unit bridges field wiring and plug-in electronic I\/O modules, accommodating a signal density of up to 1x32 or 2x16 independent terminal channels rated for an operational threshold of 50V. The unit establishes direct data bus backplane routing and localized power distribution links, eliminating separate external marshaling panels. It ensures broad cross-system integration across diverse control environments, providing backward and native hardware compatibility with \u003cstrong\u003e800xA\u003c\/strong\u003e, \u003cstrong\u003eAdvant OCS with Master SW\u003c\/strong\u003e, \u003cstrong\u003eAdvant OCS with MOD 300 SW\u003c\/strong\u003e, and the \u003cstrong\u003eCompact Product Suite\u003c\/strong\u003e. Built for reliable deployment within modern fieldbus architectures, the component facilitates simple modular maintenance cycles and high signal integrity for mixed analog and discrete process applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures high-density signal integration providing 1x32 and 2x16 terminal layout arrangements.\u003c\/li\u003e\n\u003cli\u003eCompact baseline form factor reduces physical footprint requirements within electrical control cabinets.\u003c\/li\u003e\n\u003cli\u003eSupports up to 50V field voltage distribution across active process channels.\u003c\/li\u003e\n\u003cli\u003eDesigned for passive operational longevity without specialized internal battery backups.\u003c\/li\u003e\n\u003cli\u003eEngineered for rapid plug-in insertion and removal of S800 I\/O electronic modules during lifecycle servicing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eABB S800 I\/O\u003c\/strong\u003e remote sub-rack architectures utilized in distributed control system (DCS) nodes.\u003c\/li\u003e\n\u003cli\u003eProcess machinery interfaces inside thermal power utilities, marine platforms, and chemical treatment loops.\u003c\/li\u003e\n\u003cli\u003eFactory floor fieldbus control systems incorporating Advant Fieldbus 100 networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 57.9173%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003eTU818\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e3BSE069209R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003eTU818 Compact MTU, 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eSignal Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e1x32 (and 2x16) signal terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eMaximum Rated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e58.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eDIN Rail Installation\u003c\/h3\u003e\n\u003cp\u003eMount the termination unit onto standard 35 mm DIN rail profiles. Ensure the integrated grounding clips on the rear frame seat fully against clean, unpainted metallic tracks to achieve reliable instrument ground connection.\u003c\/p\u003e\n\u003ch3\u003eModule Attachment\u003c\/h3\u003e\n\u003cp\u003eAlign the mating interface slots of the designated S800 I\/O electronic module with the base unit housing. Insert smoothly perpendicular to the rail until the latching tabs snap into position. Do not force alignment pins if resistance occurs.\u003c\/p\u003e\n\u003ch3\u003eCable Routing and Wire Stripping\u003c\/h3\u003e\n\u003cp\u003eStrip the field signal cabling insulation according to the specified wire gauge tolerances for S800 termination blocks. Route external field lines through dedicated lower wire trays, keeping low-voltage signal runs separated from high-capacity power lines to prevent signal cross-talk.\u003c\/p\u003e\n\u003ch3\u003eMoisture Protection\u003c\/h3\u003e\n\u003cp\u003eVerify the operational enclosure maintains structural ingress integrity against moisture accumulation and ambient dust. Ensure continuous environmental controls prevent moisture condensation inside the termination housing.\u003c\/p\u003e\n\u003ch3\u003eShielding Continuity\u003c\/h3\u003e\n\u003cp\u003eTerminate incoming field instrument cable shields at the dedicated ground bars positioned within the terminal assembly area to maintain low impedance pathways for electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEU Directive 2011\/65\/EU (RoHS)\u003c\/li\u003e\n\u003cli\u003eSVHC Status: No SVHC present per Bulgarian registry data (SCIP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the voltage limit specification for this termination unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe termination unit is officially rated to handle field distribution voltages not exceeding 50V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many signal lines can be terminated onto a single base block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module accommodates configurations of either 1x32 terminal arrangements or 2x16 split terminal pathways.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this MTU require internal batteries to preserve operational data?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this unit is a passive structural interconnection interface that contains 0 batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich I\/O series is this base architecture designed for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is built specifically to host the ABB S800 I\/O hardware component series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be integrated into legacy Advant OCS architectures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is fully compatible with Advant OCS with Master SW and Advant OCS with MOD 300 SW systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the physical width of this module for cabinet layout calculations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe structural net width of the termination framework is precisely 58.5 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is electrical ground continuity established for the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGrounding path connectivity is automatically completed via integrated spring clips contacting the standard DIN rail system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be done if the internal S800 I\/O module needs replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDe-energize local loop channels and release the module mounting locks to pull the device straight out without dismantling field wires.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 85371098 Customs Tariff Number refer to?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis identifier classifies the asset as an electrical control or distribution board, console, panel, or base assembly rated under 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the termination block feature conformal coating variations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit corresponds to the standard catalog specification layout; specific environment variants should refer to specific suffix lists.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668613853547,"sku":"3BSE069209R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu818v1-3bse069209r1-compact-module-termination-unit-bkoxqvrdkg3_6f8a04f9-10f4-41bd-92ef-6400f2c39e31.jpg?v=1765535590"},{"product_id":"abb-symphony-plus-spcis22-control-i-o-module","title":"ABB Symphony Plus SPCIS22 Control I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPCIS22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, mixed-signal input\/output module engineered by ABB for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSymphony Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand Harmony Rack (HR Series) distributed control system (DCS) architectures. Serving as a multi-functional field conditioning interface, this card processes a combination of analog and discrete lines on a single hardware footprint to execute closed-loop control strategies. Critical automated continuous-process environments—including municipal thermal power plants, deep-well water treatment facilities, and complex mineral processing mills—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPCIS22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto coordinate local actuator loops and instrumentation metrics simultaneously. By integrating independent analog inputs, analog outputs, digital inputs, and digital outputs onto one specialized board, this module simplifies rack topography. This integration shortens data bus processing intervals, eliminates inter-module lag, and reduces plant unprogrammed downtime during complex load-shedding transitions.\u003c\/p\u003e\n\u003ch3\u003eHardware Interface \u0026amp; Channel Topography\u003c\/h3\u003e\n\u003cp\u003eThe internal routing circuits, independent terminal counts, and signaling layers of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPCIS22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehybrid interface card provide versatile automation options within the Symphony Plus environment.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Input Matrix:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOutfitted with 4 independent analog input channels (AX) optimized to track continuous variables like pressure transmitter curves and thermal flows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Output Array:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHouses 2 high-accuracy analog output paths designed to modulate final control elements like variable frequency drives or electronic control valves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiscrete Input Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures 3 dedicated digital input channels (DX) to log binary status updates from field proximity switches and limit trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiscrete Output Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrates 4 robust digital output channels engineered to trip field relays, trigger annunciator indicators, or stroke interlock solenoids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Integration Path:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects directly into the standard S+ HR Series backplane alignment slots, utilizing standard internal data buses for host controller synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Standards \u0026amp; Dimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAsset Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Industrial System Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPCIS22\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSymphony Plus \/ Harmony Rack (HR Series) I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMixed Control Input \/ Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Input Channel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 Active Input Channels (4 Analog + 3 Digital)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Output Channel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Active Output Channels (2 Analog + 4 Digital)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e260 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e350 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Equipment Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Ambient Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C Continuous Thermal Envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-loss engineering logic design via backplane rails\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternational HS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e853890 (Electrical Machinery Parts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEurope \/ India (SCIP Registered Assembly Platform)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Diagnostics FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the hybrid channel layout of the SPCIS22 improve rack cost efficiency?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SPCIS22 combines four distinct signal types (4 AI, 3 DI, 4 DO, 2 AO) into a single card slot. This eliminates the need to purchase separate, dedicated single-signal cards for small or isolated process loops, reducing backplane footprint needs, cutting hardware costs, and simplifying spare parts inventories.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the SPCIS22 directly compatible with older Bailey Infi 90 or Network 90 hardware installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. As an integral component of the Symphony Plus HR (Harmony Rack) Series, this module is engineered for backward compatibility. It can be integrated into existing Harmony-legacy equipment racks, enabling smooth step-by-step modernization of older DCS systems without requiring a complete rework of field wiring networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat methods do technicians use to verify signal processing faults on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField technicians can track hardware health through real-time diagnostic logs in the Symphony Plus engineering station. If an open loop occurs on an analog channel or a short-circuit triggers on a digital line, the module flags an I\/O quality status warning, allowing quick location of field wiring faults.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Paths and Analog Noise Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute all incoming analog lines through twisted, shielded instrumentation cables to shield the inputs from high-frequency electromagnetic interference (EMI) inside the panel enclosure. Connect the cable shields to the dedicated cabinet earth ground bar at the terminal block side only, and cut them clean at the field instrument side. This practice prevents ground loops from introducing noise into the sensitive 4 AI and 2 AO channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Insertion Rules and Retention Security:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBefore sliding the 0.45 kg module into the rack assembly, verify that all terminal guide tracks are completely clear of dust or manufacturing debris. Gently slide the card along the rails until its rear connectors seat into the backplane bus. Tighten the integrated faceplate fasteners to protect the module from drifting out of alignment over time from low-frequency turbine or pump vibrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Heat Controls and Component Spacing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SPCIS22 operates reliably over a standard ambient temperature window of 0 to 60 deg C. To ensure long-term stability, do not block the air pathways directly above and below the card chassis. Maintain clean air convection profiles through the panel rows to prevent localized heat buildup, which can cause component degradation in heavy-duty switching zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668613984619,"sku":"SPCIS22","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-spcis22-abb-bailey-control-input-output-module-viu0fj5scq5_846742ca-9377-45a9-a2c8-26a224f0c754.jpg?v=1765535595"},{"product_id":"abb-bailey-infi-90-imasi02-analog-slave-input-module","title":"ABB Bailey Infi 90 IMASI02 Analog Slave Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIMASI02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Analog Slave Input module engineered by ABB Bailey for the rugged\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInfi 90\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcess Management System. Functioning as a high-integrity field interface, this card accepts fifteen separate process field signals from specialized sensors and translates them into a digitized format across the system backplane. Automated heavy industrial operations—such as fossil-fuel thermal power generation blocks, chemical processing reactors, and large-scale paper mills—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIMASI02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto gather critical variable feedback. The Multi-Function Processor Module (MFP) analyzes this raw input telemetry to maintain precise control loop execution. Additionally, the module supports bidirectional smart communications, allowing it to route operational commands directly from the MFP or a Smart Transmitter Terminal (STT) down to Bailey Controls smart transmitters. This capability enables remote configuration, speeds up diagnostic routines, and limits unexpected system downtime.\u003c\/p\u003e\n\u003ch3\u003eData Interfacing \u0026amp; Hardware Configuration\u003c\/h3\u003e\n\u003cp\u003eThe structural interface paths, bus layout, and internal communication lines of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIMASI02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eslave module ensure seamless data delivery inside the chassis rack.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Channel Input Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures fifteen isolated paths designed to acquire independent analog process variables simultaneously without channel cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Module Mounting Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePlugs directly into the Module Mounting Unit (MMU) backplane via terminal P1 to draw regulated +5 VDC and +\/-15 VDC operational power rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlave Expander Bus Linkage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfaces through connector P2 to bridge local input registers onto the dedicated slave expander bus for high-speed master card polling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Device Communication Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelays complex programming matrices and digital configuration commands from the system master to line-mounted smart field instruments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Verification Cluster:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOutfitted with front-facing hardware status LEDs that provide on-site validation codes during loop testing and system troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Standards\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Specification Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIMASI02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB Bailey Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInfi 90 \/ Network 90 DCS Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Slave Input Module (ASI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Input Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 Separate Process Field Signal Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Master Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-Function Processor Module (MFP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal Bus Interfacing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSlave Expander Bus Configuration via P2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Operational Voltages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5 VDC, +15 VDC, and -15 VDC Regulated Rails via P1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSmart Protocol Bridging\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBailey Controls Smart Transmitter Terminal (STT) Lines\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Environmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeavy-Duty Industrial Conformal Coating Layer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +70 deg C Continuous Environmental Envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C Secure Storage Constraints\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial System Operation FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the IMASI02 module communicate with the main system master module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IMASI02 links to its designated master module across the slave expander bus via the rear P2 connector. To establish this communication path, you must install a physical dipshunt on the backplane of the Module Mounting Unit (MMU) across the specific slot lines. If the modules are not located close enough for the bus to bridge them, or if the dipshunt is missing, communication will fail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply rails are required to drive the internal circuits of this card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe card draws its electrical power entirely through the backplane P1 connector when seated inside the chassis framework. It requires a regulated supply of +5 VDC alongside stable +\/-15 VDC voltage lines to power both the digital processing logic and the analog input conditioning arrays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan field engineers calibrate smart transmitters directly through the IMASI02 interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports bidirectional smart signaling. It can relay configuration files and operating commands received from either the Multi-Function Processor Module (MFP) or a handheld Smart Transmitter Terminal (STT) straight to connected Bailey Controls smart field transmitters.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDipshunt Configuration and Slave Expander Placement:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBefore sliding the IMASI02 into its assigned slot in the Module Mounting Unit (MMU), verify that the backplane dipshunt is securely installed on the MMU housing. The dipshunt must physically bridge the slave expander bus pins between the input slave card and its corresponding master processor. Group the modules next to each other in the rack layout to maintain clean bus connections and prevent signal reflections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Grounding and Ribbon Alignment Rules:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGently slide the card along the slot guide rails until connectors P1 and P2 mate firmly with the backplane board. Do not force the module into place, as misaligned pins can permanently damage the bus lines or short out the +5 VDC and +\/-15 VDC power traces. Ensure the chassis frame is properly connected to the single-point plant earth ground to shield the analog conversion chips from high-frequency electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Insulation Routing and Thermal Protection Protocols:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute all external analog sensor wires through dedicated, shielded twisted-pair cables to keep ambient inductive noise from distorting the 15 input channels. Connect the cable shields to ground at the termination panel only, and cut them clean at the field instrument side. Keep the panel ventilation slots clear to maintain a stable operating temperature within the certified 0 to +70 deg C window, which prevents thermal drift in the analog-to-digital converter circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668614017387,"sku":"IMASI02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-imasi02-bailey-analog-input-module-afx0yqzbfcy_07bb12a1-acd1-407e-9c6d-b5d276b7f86e.jpg?v=1765535596"},{"product_id":"abb-tu846-3bse022460r1-s800-i-o-module-termination-unit","title":"ABB TU846 3BSE022460R1 S800 I\/O Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU846\u003c\/strong\u003e is a \u003cstrong\u003eModule Termination Unit\u003c\/strong\u003e (MTU) designed for the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e system. It provides the physical housing, electrical connections, and termination points for two \u003cstrong\u003eCI840\u003c\/strong\u003e Fieldbus Communication Interfaces in a \u003cstrong\u003e1+1 redundant\u003c\/strong\u003e configuration. This unit enables \u003cstrong\u003eredundant I\/O\u003c\/strong\u003e capabilities and is engineered for \u003cstrong\u003evertical mounting\u003c\/strong\u003e within control cabinets to optimize space and thermal management. The unit distributes power and internal Modulebus signals to the hosted communication modules while maintaining complete electrical isolation and signal integrity.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports dual \u003cstrong\u003eCI840\u003c\/strong\u003e modules for fully redundant fieldbus communication.\u003c\/li\u003e\n\u003cli\u003eDesigned for vertical DIN-rail mounting to facilitate efficient cabinet layout.\u003c\/li\u003e\n\u003cli\u003eIncludes one dedicated power supply connector for secure input distribution.\u003c\/li\u003e\n\u003cli\u003eEquipped with two \u003cstrong\u003eTB807\u003c\/strong\u003e Modulebus Terminators to ensure correct bus impedance.\u003c\/li\u003e\n\u003cli\u003eBuilt-in mechanical keying prevents the insertion of incorrect module types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) and Programmable Logic Controllers (PLC).\u003c\/li\u003e\n\u003cli\u003eProcess automation industries including oil and gas, chemical, and water treatment.\u003c\/li\u003e\n\u003cli\u003eHigh-availability power generation and electrical distribution control systems.\u003c\/li\u003e\n\u003cli\u003eFactory automation environments requiring redundant I\/O infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE022460R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O System (System 800xA 4.0\/4.1\/5.0\/5.1\/6.0, Compact Product Suite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1+1 CI840 Fieldbus Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x Power Supply Connector, 2 x TB807 Modulebus Terminators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eDIN Rail Installation\u003c\/h3\u003e\n\u003cp\u003eMount the termination unit vertically onto a standard 35 mm DIN rail. Ensure the rail is properly grounded to the cabinet enclosure. Engage the top DIN rail clip first, then press the lower portion of the unit firmly against the rail until the locking mechanism clicks into place.\u003c\/p\u003e\n\u003ch3\u003ePower Connection\u003c\/h3\u003e\n\u003cp\u003eConnect the system power supply using the included power supply connector block. Verify that the input voltage complies with the requirements of the hosted communication modules before energizing the circuit. Ensure proper polarity is maintained to prevent component damage.\u003c\/p\u003e\n\u003ch3\u003eModulebus Termination\u003c\/h3\u003e\n\u003cp\u003eThe two included \u003cstrong\u003eTB807\u003c\/strong\u003e Modulebus Terminators must be installed at the designated ends of the internal bus segment. Correct termination is required to eliminate signal reflections and maintain reliable communication across the S800 I\/O structure.\u003c\/p\u003e\n\u003ch3\u003eCooling and Ventilation\u003c\/h3\u003e\n\u003cp\u003eMaintain adequate clearance above and below the vertically mounted unit to allow natural convective airflow. Do not block the ventilation paths of the hosted modules, as proper thermal dissipation prevents localized overheating.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the TU846 unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as a physical base and electrical interface that supports two fieldbus communication modules in a redundant configuration for the S800 I\/O system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module termination unit come with the necessary terminators?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the package includes two TB807 Modulebus Terminators along with one power supply connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be mounted horizontally on a DIN rail?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific model is designed exclusively for vertical mounting to ensure proper module alignment and optimal heat dissipation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich specific communication module is compatible with this MTU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is explicitly designed to host the CI840 Fieldbus Communication Interface in a 1+1 redundant setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs any special tool required to secure the power supply connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard industrial screwdrivers matching the terminal block screws are sufficient to secure the incoming power wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat control systems support this equipment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is compatible with ABB System 800xA (versions 4.0 through 6.0) and the Compact Product Suite utilizing S800 I\/O.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668617195883,"sku":"3BSE022460R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu846-3bse022460r1-module-termination-unit-s5vgviwm0sq_7ee41948-f260-41f2-bc09-d74e1f57e505.jpg?v=1765535714"},{"product_id":"abb-3bse021447r1-tu845-s800-i-o-redundant-module-termination-unit","title":"ABB 3BSE021447R1 TU845 S800 I\/O Redundant Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BSE021447R1 TU845\u003c\/strong\u003e is a dedicated \u003cstrong\u003eModule Termination Unit\u003c\/strong\u003e (MTU) designed for high-availability configurations within the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e system platform. Engineered to support redundant input\/output operational structures, this base infrastructure element provides physical housing and electrical routing connections for dual redundant I\/O modules. The unit operates safely within a maximum working voltage threshold of 50V, making it highly suitable for low-voltage signal transmission loops. By routing signals through a structured backplane configuration, the \u003cstrong\u003e3BSE021447R1\u003c\/strong\u003e enables concurrent dual-channel module connections to preserve continuous data acquisition and system control even during individual module diagnostics or field replacements. This structural solution seamlessly bridges field instrumentation wiring directly into distributed automation networks monitored by plant DCS architectures like the \u003cstrong\u003e800xA\u003c\/strong\u003e or \u003cstrong\u003eCompact Product Suite\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in support for dual redundant I\/O module assemblies to enable fail-safe process monitoring loops.\u003c\/li\u003e\n\u003cli\u003eRated for low-voltage signal deployment handling a maximum system rating of 50V.\u003c\/li\u003e\n\u003cli\u003eIntegrated vertical DIN rail mounting framework optimized to maximize internal layout density inside industrial control cabinets.\u003c\/li\u003e\n\u003cli\u003ePass-through terminal interface layout enabling convenient connection of multi-channel field sensors and actuator signal wiring.\u003c\/li\u003e\n\u003cli\u003eComponent space allocation designed to operate without the pre-installation of an integrated shunt stick accessory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant analog or digital field signal termination within \u003cstrong\u003e800xA\u003c\/strong\u003e distributed control system process nodes.\u003c\/li\u003e\n\u003cli\u003eHigh-density field wiring networks in continuous chemical plant processes, petroleum extraction plants, and petrochemical distribution hubs.\u003c\/li\u003e\n\u003cli\u003eFail-safe safety and automation sub-loops in municipal clean water networks and industrial pumping stations.\u003c\/li\u003e\n\u003cli\u003eMulti-channel instrumentation routing for critical power plant auxiliary control setups and boiler management architectures.\u003c\/li\u003e\n\u003cli\u003eDistributed tracking assets deployed within heavy-duty manufacturing equipment managed by the \u003cstrong\u003eCompact Product Suite\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eOrdering Information must be strictly evidence-based; if not explicitly present in source, omit entirely without explanation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 466.251px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"1\" style=\"width: 26.61%; height: 19.5938px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"2\" style=\"width: 26.61%; height: 19.5938px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"3\" style=\"width: 26.61%; height: 19.5938px;\"\u003eProduct ID\u003c\/td\u003e\n\u003ctd data-row=\"3\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e3BSE021447R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"4\" style=\"width: 26.61%; height: 19.5938px;\"\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd data-row=\"4\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eTU845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"5\" style=\"width: 26.61%; height: 19.5938px;\"\u003eCatalog Description\u003c\/td\u003e\n\u003ctd data-row=\"5\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eTU845 Redundant MTU, 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd data-row=\"6\" style=\"width: 26.61%; height: 39.1875px;\"\u003eLong Description\u003c\/td\u003e\n\u003ctd data-row=\"6\" style=\"width: 70.5329%; height: 39.1875px;\"\u003eUsed with redundant I\/O. Vertical DIN rail mounting. Shunt Stick not included.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"7\" style=\"width: 26.61%; height: 19.5938px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"7\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eModule_Termination_Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"8\" style=\"width: 26.61%; height: 19.5938px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-row=\"8\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eS800 I\/O (S800 I\/O 4.0 \/ 4.1 \/ 5.0 \/ 5.1 \/ 6.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"9\" style=\"width: 26.61%; height: 19.5938px;\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd data-row=\"9\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e800xA System, Compact Product Suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"10\" style=\"width: 26.61%; height: 19.5938px;\"\u003eOperational Voltage\u003c\/td\u003e\n\u003ctd data-row=\"10\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eMaximum 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"11\" style=\"width: 26.61%; height: 19.5938px;\"\u003eRedundancy Capability\u003c\/td\u003e\n\u003ctd data-row=\"11\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eSupported (Used with redundant I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"12\" style=\"width: 26.61%; height: 19.5938px;\"\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd data-row=\"12\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"13\" style=\"width: 26.61%; height: 19.5938px;\"\u003eShunt Stick Included\u003c\/td\u003e\n\u003ctd data-row=\"13\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.5938px;\"\u003e\n\u003ctd data-row=\"14\" style=\"width: 26.61%; height: 15.5938px;\"\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd data-row=\"14\" style=\"width: 70.5329%; height: 15.5938px;\"\u003e186.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"15\" style=\"width: 26.61%; height: 19.5938px;\"\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd data-row=\"15\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd data-row=\"16\" style=\"width: 26.61%; height: 39.1875px;\"\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n\u003ctd data-row=\"16\" style=\"width: 70.5329%; height: 39.1875px;\"\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"17\" style=\"width: 26.61%; height: 19.5938px;\"\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd data-row=\"17\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"18\" style=\"width: 26.61%; height: 19.5938px;\"\u003eNumber of Batteries\u003c\/td\u003e\n\u003ctd data-row=\"18\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"19\" style=\"width: 26.61%; height: 19.5938px;\"\u003eRoHS Information\u003c\/td\u003e\n\u003ctd data-row=\"19\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"20\" style=\"width: 26.61%; height: 19.5938px;\"\u003eWEEE Category\u003c\/td\u003e\n\u003ctd data-row=\"20\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"21\" style=\"width: 26.61%; height: 19.5938px;\"\u003eHS Code\u003c\/td\u003e\n\u003ctd data-row=\"21\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"22\" style=\"width: 26.61%; height: 19.5938px;\"\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd data-row=\"22\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eTerminal \/ Connection Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eDual Module Slots\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBuilt-in matching interfaces providing concurrent electrical links for redundant I\/O module pairs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBase Wire Terminals\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eStructured physical wire termination points for external instrumentation inputs and control loop paths.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e Mount the hardware module framework strictly in a vertical orientation onto a standard 35 mm industrial DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComponent Verification:\u003c\/strong\u003e Ensure that any required external shunt stick devices are sourced separately before commencing full loop integration, as they are not pre-packaged with the base unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Constraints Check:\u003c\/strong\u003e Verify that the connected signal loops and auxiliary power sources do not exceed the absolute operational specification ceiling of 50V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Spacing:\u003c\/strong\u003e Arrange adjacent components inside the electrical cabinet to properly accommodate the unit's net height of 124 mm and width of 186.5 mm, ensuring adequate airflow and routing clearances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Alignment:\u003c\/strong\u003e Seat both the primary and secondary I\/O modules firmly into their designated base slots to guarantee complete channel coupling and continuous circuit tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary technical use of this termination unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware is designed to provide structural termination and signal routing paths for dual redundant module setups within the S800 I\/O product line.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this specific product arrive with an integrated shunt stick included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the tracking data explicitly confirms that the shunt stick component is not included and must be provided separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the absolute maximum working voltage defined for this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware is rated to manage low-voltage signal transmission loops running up to a maximum parameter of 50V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this particular unit physically positioned and fixed inside a cabinet enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module termination unit is explicitly configured for vertical mounting onto standard industrial DIN rail tracks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich primary distributed automation architectures are fully compatible with this component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is natively matched with ABB 800xA and Compact Product Suite platforms utilizing S800 I\/O variations from version 4.0 through 6.0.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the exact physical net weight of this standalone termination base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe baseline equipment has an individual net hardware weight of exactly 0.6 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any toxic internal battery sub-assemblies inside this hardware structure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the unit is constructed with zero internal batteries, minimizing hazardous waste and simplified disposal processes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the exact physical outline metrics for panel layout planning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe structural housing tracks at a width of 186.5 mm, a height of 124 mm, and a net thickness depth of 64 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat structural commodity code governs international customs shipping for this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe verified global tariff index records this equipment under Customs Tariff Number 85371098 and HS Code 853710.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware follow European environmental substance restrictions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the manufacturing guidelines comply fully with the parameters set forth in EU RoHS Directive 2011\/65\/EU.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668618080619,"sku":"ABB TU845 3BSE021447R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu845-3bse021447r1-redundant-termination-unit-4ucdhdk4koj_ed1bbdaa-0c31-4e5e-be18-9e3d9c2034e3.jpg?v=1765535749"}],"url":"https:\/\/www.plcprotech.com\/collections\/i-o-modules.oembed?page=8","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}