{"title":"New arrivals","description":"\u003cp\u003eExplore our newest inventory of high-performance industrial automation hardware. This collection features the latest arrivals in PLC modules, DCS components, and machinery monitoring systems from industry leaders. We have recently updated our stock with genuine spares for\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/abb-s800-i-o\" class=\"ng-star-inserted\" target=\"_blank\"\u003eABB S800 I\/O\u003c\/a\u003e,\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3500-system-machinery-protection\" class=\"ng-star-inserted\" target=\"_blank\"\u003eBently Nevada 3500\u003c\/a\u003esensors, and\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/honeywell-experion-pks-c300-series-c\" class=\"ng-star-inserted\" target=\"_blank\"\u003eHoneywell C300\u003c\/a\u003econtrollers. Whether you need urgent replacements for\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/allen-bradley-controllogix\" class=\"ng-star-inserted\" target=\"_blank\"\u003eAllen-Bradley Controllogix\u003c\/a\u003eor\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/ge-boards-turbine-control\" class=\"ng-star-inserted\" target=\"_blank\"\u003eGE Turbine Control\u003c\/a\u003eboards, our new arrivals are verified, 100% genuine, and ready for immediate global dispatch to minimize your facility's downtime.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-285694-02-3500-61e-6-channel-temperature-monitor","title":"Bently Nevada 285694-02 3500\/61E 6-Channel Temperature Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285694-02 (3500\/61E)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, six-channel temperature monitoring module designed for the Bently Nevada 3500 ENCORE machinery protection system. Primarily utilized in heavy-duty gas turbines, steam turbines, and large-scale compressors within the power generation and oil and gas sectors, this module provides critical protection for motor windings and bearing temperatures. By continuously processing Resistance Temperature Detector (RTD) signals and comparing them against user-programmable Alert and Danger setpoints, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285694-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that thermal excursions are detected before catastrophic mechanical failure occurs. Its ability to integrate into both legacy 3300 rack upgrades and modern ENCORE system racks makes it a versatile solution for reducing plant downtime and extending the lifecycle of rotating assets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285694-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis configured as a non-isolated RTD monitor, optimized for high-density thermal sensing where 3-wire or 4-wire platinum sensors are standard.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports 100 Ohm Platinum (alpha = 0.00385 or 0.00392), 120 Ohm Nickel, and 10 Ohm Copper RTDs. Platinum RTD (0.00385) is the recommended worldwide industrial standard for highest accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Adaptability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn \"Rack Upgrade\" mode, it interfaces with existing 3300 series I\/O modules and relays. In \"ENCORE System\" mode, it utilizes logic-programmable Relay Modules for alarm driving.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a dedicated 913 microampere current source per transducer (single supply for 4-wire, dual for 3-wire) to ensure stable resistance measurement over long cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Visibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with front-panel LEDs for OK, Alert, Danger, and Bypass status, providing immediate local diagnostic feedback to maintenance personnel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e285694-02 (3500\/61E)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6-Channel RTD (Resistance Temperature Detector)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRTD Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Ohm Platinum, 120 Ohm Nickel, 10 Ohm Copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.6 watts nominal (RTD Option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA (Individual for each channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 deg C or 1 deg F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy (Platinum)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 1 deg C max (range limited to 150 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreater than 3 MOhm for each lead\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +12 VDC range across load (0 to 600 Ohm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 3500\/61E handle \"Rack Upgrade\" vs. \"Full System\" installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn a Rack Upgrade, the 3500\/61E replaces the 3300\/30 or 3300\/35 monitor while using the original 3300 I\/O and relays. In a full ENCORE System, it uses new ENCORE Temperature I\/O modules and a programmable relay module to drive alarms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs field calibration required for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. All configuration parameters are set via the 3500 Rack Configuration Software. The module's high-precision internal circuitry eliminates the need for manual field calibration once the transducer type and range are defined.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the impact of a short circuit on the recorder outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor operation is completely unaffected by short circuits on the 4 to 20 mA recorder outputs. This design ensures that a fault in the DCS\/PLC signal line will not compromise the primary machinery protection logic.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines and Field Engineering Advice\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRTD Wiring Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor 3-wire RTD installations, ensure all three leads have nearly identical resistance and are routed together. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285694-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses two current sources for 3-wire compensation; significant lead resistance imbalance will introduce temperature measurement errors that could lead to false trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBarrier Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen using external intrinsic safety barriers, note that the lower \"OK\" limit of the sensor is typically restricted to -50 deg C. Ensure the 3500 Configuration Software is adjusted to account for the added resistance of the barriers to maintain measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Logic Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn an ENCORE System configuration, remember that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edoes not have onboard relays. It must be mapped to a 3500 Relay Module. Verify that the \"Bypass\" status of the monitor is correctly reflected in the plant's safety interlocking logic during maintenance to prevent blind operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Best Practices:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo minimize electromagnetic interference (EMI) on low-level RTD signals, use shielded twisted-pair cabling. Terminate shields only at the 3500 rack ground bus to avoid ground loops that can cause signal \"drifting\" or erratic Alert\/Danger triggers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516668779,"sku":"3500\/61E 285694-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61e-285694-02-temperature-monitor-f3g3ccfvs2b_d717d800-41d8-4ef7-ba75-cc9da7657211.jpg?v=1765440094"},{"product_id":"bently-nevada-330910-03-09-05-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330910-03-09-05-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330910-03-09-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 3300 NSv (Narrow Side View) proximity transducer engineered for high-precision vibration and position monitoring in constrained industrial environments. This M10X1 threaded probe is the industry standard for process compressors, high-speed gearboxes, and aero-derivative gas turbines where side-view clearance is limited. Utilizing patented\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTipLoc\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emolding for a robust tip-to-body bond and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCableLoc\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesign for 220 N pull strength, this probe offers significantly higher chemical resistance than legacy 3300 RAM models. Its narrow magnetic field allows for accurate gapping even in tight mechanical housings, effectively reducing noise interference. By providing critical shaft dynamic data to the 3500 Machinery Protection System, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330910-03-09-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplays a pivotal role in preventing catastrophic asset failure and optimizing maintenance cycles in petrochemical and power generation facilities.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric sequence for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330910-03-09-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefines the specific mechanical and certification parameters required for site-specific integration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03 (Unthreaded Length):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30 mm unthreaded case section.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e09 (Overall Case Length):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90 mm total case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Total Length):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 meter (20 inch) total lead length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02 (Connector and Cable):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMiniature coaxial ClickLoc connector with standard cable and integrated stainless steel armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Agency Approval):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultiple global approvals including FCC, ATEX, IECEx, and CSA for use in intrinsically safe hazardous areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330910-03-09-05-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10X1 Metric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLead Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-52 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Altitude\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Sealing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eViton O-ring (differential pressure seal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePull Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 N (50 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.6 N-m (200 in-lb) maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Calibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 Steel (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAsset Protection FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3300 NSv probe interchangeable with the older 3300 RAM series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 3300 NSv probe and extension cables are both mechanically and electrically compatible with previous 3300 RAM hardware, allowing for seamless site upgrades with enhanced chemical resistance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Narrow Side View\" advantage in tight spaces?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard probes require a large clear area around the tip to prevent \"side-loading\" interference from the machine housing. The NSv series has superior side-view characteristics, allowing it to maintain signal accuracy when gapped in narrow channels or near adjacent metal surfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is sustained exposure below -34 deg C a concern?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the probe is rated for operation down to -52 deg C, prolonged exposure to temperatures below -34 deg C (-30 deg F) can degrade the elasticity of the internal Viton O-ring, potentially causing a premature failure of the process pressure seal.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Installation and Commissioning Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement and Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor M10X1 probe cases, the maximum thread engagement is limited to 15 mm. During installation, the mounting torque must not exceed 22.6 N-m (200 in-lb) for the first three threads to prevent case deformation. Use a second locknut to secure the final gap setting against vibration-induced drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClickLoc Connector Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the gold-plated brass ClickLoc connectors are fully seated and \"clicked\" into place. This prevents signal attenuation caused by loosening. In turbine oil environments, avoid using silicone tape on the probe-to-extension cable junction; instead, use designated connector protectors to prevent oil ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Viton O-ring provides a differential pressure seal between the probe tip and the case. If the application involves high-pressure process gases or specialized chemicals, verify chemical compatibility with Viton and consider pressure testing the seal post-installation if mandated by site safety protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring gapping, utilize a -24 VDC power supply and a 10 kOhm load. Ensure the probe is gapped at 1.0 mm (40 mils) against a 31 mm diameter (or larger) AISI 4140 steel target to achieve optimal linearity and interchangeability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516767083,"sku":"330910-03-09-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330910-03-09-05-02-05-proximity-transducer-nj1jrvb3gpw_402b4bd6-63db-424e-9dfd-edd5ef5fdc5c.jpg?v=1765440096"},{"product_id":"bently-nevada-330909-00-80-10-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330909-00-80-10-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330909-00-80-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 3300 NSv Proximity Probe engineered for critical machinery protection in space-constrained or chemically aggressive environments. This probe is specifically designed for process compressors and small-bore centrifugal pumps frequently found in oil refineries and chemical processing plants. Featuring advanced chemical resistance and a 3\/8-24 UNF threaded case with integrated stainless steel armor, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330909-00-80-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides superior durability compared to legacy 3300 RAM series sensors. It utilizes Bently Nevada patented technologies, including TipLoc molding for robust tip-to-body bonding and CableLoc for high pull-strength cable attachment. By providing reliable eddy-current displacement measurements, this transducer system is vital for monitoring shaft vibration and position, effectively preventing catastrophic failures and minimizing unplanned facility downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric configuration for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330909-00-80-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefines the specific mechanical and certification parameters for field integration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Unthreaded Length):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.0 inch unthreaded length; fully threaded case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e80 (Overall Case Length):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8.0 inch overall case length, providing sufficient reach for deep-well machine casing penetrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10 (Total Length):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.0 meter (39 inch) total lead length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02 (Connector and Cable):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMiniature coaxial ClickLoc connector with standard cable and integrated stainless steel armor for physical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Agency Approval):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultiple global approvals including FCC, ATEX, IECEx, and CSA for use in intrinsically safe hazardous areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330909-00-80-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv (Narrow Side View)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 meter lead\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-52 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Sealing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eViton O-ring internal seal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 Steel (Standard Calibration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 mm (60 mils) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePull Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 N (50 lb) via CableLoc design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Protection FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3300 NSv probe backward compatible with older 3300 RAM systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 3300 NSv probe and extension cables are mechanically and electrically interchangeable with the previous 3300 RAM series. However, the NSv series offers significantly better chemical resistance for process gas applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Narrow Side View\" advantage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"NSv\" designation indicates a tighter magnetic field pattern. This allows the probe to be installed in tighter spaces with less interference from surrounding metal (side-view) compared to standard 3000-series probes, ensuring a more accurate vibration signal in compact machines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is it important to avoid sustained temperatures below -34 deg C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the probe can operate at -52 deg C, prolonged exposure to temperatures below -34 deg C (-30 deg F) can cause the internal pressure seal to become brittle. This may lead to premature seal failure and potential process media leakage into the housing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering and Installation Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Thread Engagement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor the 3\/8-24 UNF threaded case, ensure the maximum thread engagement does not exceed 0.563 inches to prevent mechanical binding. Use a calibrated torque wrench for the final locknut set, ensuring the probe remains stationary during high-vibration events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Integrity (ClickLoc):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll ClickLoc connectors are gold-plated brass. During installation, ensure the connectors \"click\" into a locked position. It is highly recommended to use connector protectors or silicone tape to prevent the ingress of turbine oil or moisture, which can bridge the coaxial signal and cause \"Not OK\" status at the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArmor Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated stainless steel armor protects the coaxial lead from mechanical abrasion. However, maintain a minimum bend radius of 25 mm (1.0 inch) to avoid damaging the internal miniature coaxial conductor. Do not allow the armor to come into direct contact with high-voltage lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring commissioning, set the probe gap to the standard 1.0 mm (40 mils), which corresponds to approximately -10 VDC on a standard Proximitor output when using an AISI 4140 steel target. Always verify the target material before final gapping, as non-4140 materials require specialized Proximitor calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516832619,"sku":"330909-00-80-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330909-00-80-10-02-05-sensor-proximity-probe-cable-via-fedex-pmvvusodgop_86432078-a2ee-4b4e-843c-4170b8ad4747.jpg?v=1765440097"},{"product_id":"bently-nevada-3500-50-133388-02-tachometer-module","title":"Bently Nevada 3500\/50 133388-02 Tachometer Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/50\u003c\/strong\u003e, designated under spare part number \u003cstrong\u003e133388-02\u003c\/strong\u003e, is a 2-channel hardware component engineered to determine shaft rotative speed, rotor acceleration, or rotor direction within the 3500 Machinery Protection System. The module interfaces directly with raw proximity probe transducers or passive magnetic pickups to monitor physical asset dynamics. Acting as an analytical interface layer, it continuously compares acquired frequency data against user-programmable alarm setpoints, changing states to trip automated safety alarms when thresholds are exceeded. Configurable through the 3500 Rack Configuration Software, the module can supply conditioned Keyphasor signals to the backplane network, eliminating the need for independent Keyphasor hardware installations. The instrument outputs an independent +4 to +20 mA analog recorder signal for each measurement channel to supply plant operations and logging utilities with deterministic diagnostic indicators.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual independent channel capabilities for multi-point frequency or rotational direction tracking.\u003c\/li\u003e\n\u003cli\u003eVersatile sensor acceptance supporting both eddy current proximity systems and passive magnetic pickups.\u003c\/li\u003e\n\u003cli\u003eFour standard firmware options comprising speed monitoring, speed band, zero speed, acceleration, and reverse rotation tracking.\u003c\/li\u003e\n\u003cli\u003eIntegrated peak hold logic capturing maximum forward speed, maximum reverse speed, and cumulative reverse rotations.\u003c\/li\u003e\n\u003cli\u003eInternal rack signal distribution delivering conditioned Keyphasor reference data to adjacent 3500 series monitors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial steam and gas turbine rotor shaft speed tracking and peak rotation monitoring.\u003c\/li\u003e\n\u003cli\u003eCentrifugal process gas compressor acceleration observation and emergency shutdown interface.\u003c\/li\u003e\n\u003cli\u003eLarge-scale cooling tower fan zero speed validation and reverse rotation notification.\u003c\/li\u003e\n\u003cli\u003eHigh-horsepower industrial gearbox input-to-output shaft speed ratio monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/50-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTachometer Module\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: I\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Terminations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with External Terminations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eTMR I\/O Module with External Terminations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Barriers and Internal Terminations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Monitor Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eSpeed Measurement \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eReverse Rotation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e133388-02\u003c\/td\u003e\n\u003ctd\u003e3500\/50 Tachometer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/50 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133388-02 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Input Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 proximity probe transducers or magnetic pickups \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10.0 V to -24.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTMR Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Barrier Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.15 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 Watts typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Proportional Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Voltage Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc across load \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Load Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 600 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc, 40 mA maximum per channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Supported Input Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Full Scale Speed Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99,999 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximity Probe Frequency Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 0.0167 Hz (1 rpm for 1 event\/revolution) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMagnetic Pickup Frequency Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 3.3 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM Accuracy (\u0026lt; 100 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.1 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM Accuracy (100 to 10,000 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±1 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM Accuracy (\u0026gt; 10,000 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.01% of true shaft speed \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRotor Acceleration Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±20 rpm\/min \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Triggering Amplitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 1 volt peak-to-peak \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManual Triggering Scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+9.5 Vdc to -23.5 Vdc with 500 mV peak-to-peak minimum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Trigger Hysteresis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser selectable from 0.2 to 2.5 volts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm 1 Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 60 seconds in 1 second intervals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm 2 Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 60 seconds in 0.1 second intervals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp (Standard I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 Celsius to +65 Celsius (-22 Fahrenheit to +150 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp (Barrier I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Celsius to +65 Celsius (32 Fahrenheit to +150 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to +85 Celsius (-40 Fahrenheit to +185 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing relative humidity \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Monitor Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg (1.8 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight (Non-Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight (Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Monitor Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (Non-Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Rack Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot and 1 full-height rear slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Connector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH1 BNC (Front Face)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Transducer Coaxial Output for Channel 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH2 BNC (Front Face)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Transducer Coaxial Output for Channel 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O TRANSDUCERS (CHI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePWR \/ COM \/ SIG \/ SHLD Terminal Blocks for Sensor Input 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O TRANSDUCERS (CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePWR \/ COM \/ SIG \/ SHLD Terminal Blocks for Sensor Input 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCONTACTS Terminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRESET (PRST1 \/ PRST2) and Zener Barrier Enable Interlocks \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUFFERED TRANSDUCERS Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Euro-style Output Pins for External Oscilloscopes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRECORDER OUTPUTS Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated COM \/ REC1 \/ REC2 \/ SHLD Current Loop Interfaces \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGrounding Control: Terminate field sensor cable shields explicitly at the designated SHLD pins on the rear termination blocks to build an effective faraday path against high-frequency electrical noise.\u003c\/li\u003e\n\u003cli\u003eSlot Alignment: Insert the main front module into any available full-height slot location, pushing firmly along the alignment tracks until the card engages with the rack backplane power lines.\u003c\/li\u003e\n\u003cli\u003eSensor Exclusions: Do not map magnetic pickup inputs to zero speed or reverse rotation notification functions, as low shaft velocity cannot generate sharp edge signals for proper trigger interpretation.\u003c\/li\u003e\n\u003cli\u003eVentilation Integrity: Ensure clearance tracks are maintained on both the front face and rear interface regions to facilitate ambient forced-air cooling paths through the instrument chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Mark Directives: EN50081-2 Radiated and Conducted Emissions (Class A), EN50082-2 Industrial Susceptibility Standard.\u003c\/li\u003e\n\u003cli\u003eLow Voltage Directives: EN 61010-1 Environmental Safety Requirements for Electrical Equipment.\u003c\/li\u003e\n\u003cli\u003eCSA \/ NRTL \/ C: Certified for Class I, Division 2, Groups A through D installations when combined with matching standard termination modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this instrument independently control plant machinery overspeed trip valves?\u003c\/strong\u003e A: No, Bently Nevada tachometer modules are not engineered as components for standalone speed control or direct overspeed protection, as they lack the critical structural redundancy needed for machinery trip functions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the physical operational difference between part number 133388-02 and the 3500\/50 series designation?\u003c\/strong\u003e A: The 3500\/50 identifies the overall functional tachometer module design family, while the reference 133388-02 dictates the specific warehouse spare component identifier for the front card assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is manual calibration necessary for the analog output loop upon deployment?\u003c\/strong\u003e A: No field-level calibration routines are necessary, since all transmitter input ranges, voltage thresholds, and discrete parameters are processed digitally using the 3500 software layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a magnetic pickup be safely assigned to verify reverse rotation behavior?\u003c\/strong\u003e A: No, passive magnetic pickups fail to deliver a distinct or clean signal edge during slow or stopping shaft cycles, which can cause severe faults or incorrect direction tracking within the logic layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does a sudden external short circuit on the analog recorder loop affect overall speed tracking?\u003c\/strong\u003e A: The primary speed tracking, alarm monitoring, and backplane processing operations remain completely uninfluenced by short-circuit faults across the external recorder line loops.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519552363,"sku":"3500\/50 133388-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-50-133388-02-tachometer-module-fzrkzbolckl_a2fc124d-c18b-438a-9eb8-c8d07efe8699.jpg?v=1765440133"},{"product_id":"bently-nevada-32000-28-05-15-080-03-02-metric-proximity-probe-housing-assembly","title":"Bently Nevada 32000-28-05-15-080-03-02 Metric Proximity Probe Housing Assembly","description":"\u003ch3\u003eCommercial Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32000-28-05-15-080-03-02\u003c\/strong\u003e is a specialized, metric-threaded proximity probe housing assembly engineered by Bently Nevada for heavy-duty machinery protection systems. Designed for deployment in demanding environments such as gas turbine power plants, petrochemical refineries, and marine propulsion systems, this ruggedized hardware safeguards critical eddy current sensors from external mechanical impact and chemical exposure. The main junction housing is injection-molded from glass-reinforced polyphenylene sulfide (PPS), delivering exceptional dimensional stability and static dissipation. By facilitating safe external probe gaps and sensor swaps while the monitored machine remains online, this assembly eliminates catastrophic failures and drastically cuts down plant maintenance overhead.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32000:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMetric proximity probe housing base assembly featuring a corrosion-resistant, high-performance PPS thermoplastic junction enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-28:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 3300 XL 8 mm proximity probe assembly with agency approvals for hazardous environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProbe unarmored cable length option configured at 0.5 meters (20 inches).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-15:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtended standoff adapter length precision-machined to 150 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-080:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard probe sleeve penetration length set at 80 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-03:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFitting configurations inclusive of two explosion-proof blanking plugs, one M20 conduit entry fitting, and one specialized cable seal grip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMounting connection specifying 3\/4-14 NPT external coupling threads for rigid standoff adapter installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eParameter\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e32000-28-05-15-080-03-02\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBrand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBently Nevada\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOrigin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUnited States\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eProximity Probe Housing Assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEnclosure Material\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGlass-filled Polyphenylene Sulfide (PPS)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSleeve \u0026amp; Standoff Material\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAISI 304 Stainless Steel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTransducer Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandoff Length\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e150 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePenetration Depth\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e80 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMounting Interface\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3\/4-14 NPT External\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConduit Entry Thread\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eM20 x 1.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIngress Protection Rating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP66 \/ Type 4X\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAmbient Temperature Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-35 to 177 deg C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eApproximate Weight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.2 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e315 mm x 115 mm x 115 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core structural difference between this model and the shorter -08 standoff variant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -15 suffix designates an extended 150 mm standoff adapter length. This extended configuration provides additional clearance to bridge thick thermal insulation blankets or complex external piping networks commonly found on high-temperature steam or gas turbines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the PPS plastic housing perform when exposed to aggressive industrial chemicals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe glass-reinforced PPS construction exhibits superior chemical inertness. It withstands prolonged exposure to synthetic lubricants, ammonia, hydrogen sulfide, and caustic washdown agents without cracking, corroding, or losing its static-dissipative properties.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an external grounding strap required for this non-metallic junction housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The advanced PPS formulation is intrinsically engineered to be static-dissipating. However, the stainless steel standoff adapter and sleeve provide a direct metal-to-metal bond to the machine casing, ensuring proper system grounding.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Safety Directives\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInitial Mechanical Fit-Up\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect the machine port threads before installation. Thread the stainless steel sleeve through the 3\/4-14 NPT mounting adapter until the 3300 XL probe tip carefully seats against the target shaft area.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLinear Range Alignment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect a standard digital multimeter across the signal and COM lines of the corresponding Proximitor monitor. Back the sleeve out slowly until the DC gap voltage reaches -10.0 VDC (the nominal midpoint of the 80 mil linear range) before clamping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Application\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSecure the outer locknut assembly using a calibrated wrench to a torque limit of 34 N-m. Exceeding this torque limit when handling the PPS polymer structural housing can lead to localized thread stripping or casing fracturing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the 0.5-meter internal probe cable through the provided cable seal grip without putting sharp bends on the coaxial line. Ensure the minimum bend radius of 25.4 mm (1.0 inch) is maintained inside the housing enclosure.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666541146475,"sku":"32000-28-05-15-080-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-32000-28-05-15-080-03-02-metric-proximity-probe-housingassemblies-tpqyhvp4a0q_4a8a7495-09e1-4093-b084-023216670481.jpg?v=1765440468"},{"product_id":"bently-nevada-991-25-70-01-05-thrust-transmitter","title":"Bently Nevada 991-25-70-01-05 Thrust Transmitter","description":"\u003cp\u003eThe Bently Nevada 991-25-70-01-05 is a 2-wire loop-powered thrust (axial displacement) transmitter developed for OEM machinery monitoring applications on compressors, pumps, motors, and rotating equipment. It converts the proximity probe signal into a standard 4–20 mA output for direct integration with PLC, DCS, or control systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eSuffix CodeOption \/ ParameterTechnical Description\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e-25\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-70\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e7.0 meters (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e-01\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eMounting Option\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e35 mm DIN-rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e-05\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCSA Division 2, ATEX Zone 0, ATEX Zone 2, ABS maritime approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated proximity probe driver circuit\u003c\/li\u003e\n\u003cli\u003e4–20 mA proportional axial displacement output\u003c\/li\u003e\n\u003cli\u003eNon-interacting Zero and Span adjustments\u003c\/li\u003e\n\u003cli\u003ePower-up signal suppression to avoid false trips\u003c\/li\u003e\n\u003cli\u003e“Not OK” signal blanking diagnostics\u003c\/li\u003e\n\u003cli\u003eDedicated PROX OUT dynamic signal connector\u003c\/li\u003e\n\u003cli\u003eEncapsulated construction for high-humidity environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterDescription\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eCompatible Probe\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e3300 NSv proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e4–20 mA DC loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e+12 to +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eDynamic Output\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003ePROX OUT coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eHumidity Rating\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0.43 kg (0.95 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Steps\u003c\/h3\u003e\n\u003ch4\u003ePhysical Mechanical Mounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the transmitter onto a standard 35 mm DIN rail\u003c\/li\u003e\n\u003cli\u003eInstall away from high-temperature sources\u003c\/li\u003e\n\u003cli\u003eUse a 304 stainless steel enclosure for outdoor environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProbe Installation \u0026amp; Gapping\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse only matched 3300 NSv probe systems\u003c\/li\u003e\n\u003cli\u003eMaintain a total system cable length of exactly 7.0 meters\u003c\/li\u003e\n\u003cli\u003eVerify the shaft target area meets minimum sizing requirements\u003c\/li\u003e\n\u003cli\u003eAdjust the probe to the midpoint of the linear operating range\u003c\/li\u003e\n\u003cli\u003eConfirm the PROX OUT voltage is approximately 6.5 Vdc\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Loop Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the transmitter to a +12 to +35 Vdc loop supply\u003c\/li\u003e\n\u003cli\u003eVerify Power (+) and Signal (-) polarity before energizing\u003c\/li\u003e\n\u003cli\u003eTighten the miniature coaxial connector securely\u003c\/li\u003e\n\u003cli\u003eGround the cable shield at the control cabinet side only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eZero \u0026amp; Span Calibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAdjust the Zero potentiometer at the mechanical center position\u003c\/li\u003e\n\u003cli\u003eSet loop output current to 12 mA during midpoint calibration\u003c\/li\u003e\n\u003cli\u003eAdjust the Span potentiometer at full-scale displacement\u003c\/li\u003e\n\u003cli\u003eNon-interacting potentiometers minimize recalibration iterations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eWhy is the initial probe gap important?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncorrect gaps limit usable measurement range\u003c\/li\u003e\n\u003cli\u003eImproper installation may allow probe-to-rotor contact\u003c\/li\u003e\n\u003cli\u003eThe operating gap must remain within 0.25 to 1.65 mm (10 to 65 mils)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhy does the loop current drop below 3.6 mA?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe transmitter has entered “Not OK” protection mode\u003c\/li\u003e\n\u003cli\u003eProbe or extension cable may be open or shorted\u003c\/li\u003e\n\u003cli\u003eThe coaxial connector may not be fully seated\u003c\/li\u003e\n\u003cli\u003eThe failsafe output prevents false PLC or DCS trip signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCan an oscilloscope connect directly to the PROX OUT port?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe PROX OUT connector is non-isolated from the 4–20 mA loop\u003c\/li\u003e\n\u003cli\u003eStandard grounded oscilloscopes can create ground loops\u003c\/li\u003e\n\u003cli\u003eUse a battery-powered meter or isolated interface adapter instead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCan the extension cable be shortened or spliced?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eModifying cable length is strictly prohibited\u003c\/li\u003e\n\u003cli\u003eCable impedance changes affect calibration accuracy\u003c\/li\u003e\n\u003cli\u003eShortening or extending the cable invalidates factory calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility Notes\u003c\/h3\u003e\n\u003cp\u003eThe transmitter is specifically designed for use with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBently Nevada 3300 NSv proximity probe systems\u003c\/li\u003e\n\u003cli\u003eOEM centrifugal compressors\u003c\/li\u003e\n\u003cli\u003eSmall pumps and rotating machinery\u003c\/li\u003e\n\u003cli\u003ePLC and DCS analog input systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666735296875,"sku":"991-25-70-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-25-70-01-05-thrust-transmitter-4nnys1eggun_8af749c8-fb0e-4137-a612-cfed2c951e30.jpg?v=1765446775"},{"product_id":"bently-nevada-9200-06-02-10-00-two-wire-transducer","title":"Bently Nevada 9200-06-02-10-00 Two-Wire Transducer","description":"\u003cp\u003eThe \u003cstrong\u003e9200\u003c\/strong\u003e standard velocity transducer, complete part number \u003cstrong\u003e9200-06-02-10-00\u003c\/strong\u003e, is a two-wire moving-coil transducer designed to measure absolute casing vibration on rotating machinery. The mechanical system features a wire-suspended coil moving around a permanent magnet, providing a voltage output directly proportional to vibration velocity. This self-generating sensor requires no external power and operates within a dedicated orientation window defined by its specific option configuration. The 9200 series utilizes rotor dynamics principles to continuously monitor structural casing movement, ensuring critical machinery protection and interfacing directly with Bently Nevada monitoring systems through low-impedance signal transmission.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-06: Transducer Mounting Angle \/ Minimum Operating Frequency\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e0 ±100° (horizontal placement orientation), 10 Hz (600 cpm) minimum operating frequency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02: Connector Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHermetically sealed side-mount 2-pin connector interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10: Mounting Base Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCircular base geometry featuring an M10X1 threaded stud connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Agency Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo standard hazardous area approvals or certificates required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-02-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Moving-Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100° (Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Operating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSide Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Base Geometry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircular with M10X1 Threaded Stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase and Adapter Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the sensor installation angle precisely matches the 0 ±100° horizontal range specification to avoid physical internal coil binding against the magnet housing.\u003c\/li\u003e\n\u003cli\u003eOperating the transducer below the specified 10 Hz frequency limit causes significant amplitude attenuation and phase shift errors in velocity data.\u003c\/li\u003e\n\u003cli\u003eCross-axis vibration sensitivity must be minimized by aligning the primary measurement axis directly parallel to the intended machinery vibration direction.\u003c\/li\u003e\n\u003cli\u003eThe self-generating coil assembly introduces a fixed internal impedance that must be matched with compatible monitoring instrumentation inputs to prevent signal loading effects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplement dedicated shield grounding protocols by connecting the cable shield at the monitoring rack end only, ensuring the transducer end remains isolated to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing segregation by separating transducer signal lines from high-voltage AC power distribution conduits to reduce electro-magnetic interference.\u003c\/li\u003e\n\u003cli\u003eAvoid exceeding the minimum bending radius of the field wiring cable to prevent internal conductor damage or degradation of the insulation barrier.\u003c\/li\u003e\n\u003cli\u003eVerify the structural integrity of the M10X1 mounting surface, ensuring it is flat, smooth, and free of paint or debris to guarantee accurate high-frequency vibration transmission.\u003c\/li\u003e\n\u003cli\u003eApply correct torque specifications when securing the circular mounting base to the machine casing to prevent resonant frequencies from distorting the velocity readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this 9200-06-02-10-00 model be mounted in a purely vertical orientation on a machine casing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the -06 suffix designates a horizontal mounting configuration of 0 ±100 degrees; vertical mounting requires a different option code to calibrate the internal spring-coil alignment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What components are included inside the shipping box for this specific part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The package contains the brand-new original 9200-06-02-10-00 velocity transducer assembly with its integrated side-mount connector and M10X1 circular mounting base stud.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this specific transducer module require a separate external power supply to output the velocity signal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this is a self-generating electro-magnetic moving-coil sensor that produces its own voltage output relative to velocity without requiring external loop power.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666764493163,"sku":"9200-06-02-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-02-10-00-two-wire-transducer-wh1b32koul4_e61ad530-9ea0-4ba5-a008-11769c81ce20.jpg?v=1765447197"},{"product_id":"bently-nevada-125712-01-spare-4-channel-relay-module","title":"Bently Nevada 125712-01 Spare 4-Channel Relay Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e125712-01\u003c\/strong\u003e is a full-height spare module designed to provide four independent programmable relay outputs within a machinery protection system. It functions as the core component of the \u003cstrong\u003e3500\/32\u003c\/strong\u003e system, allowing user-programmed voting logic to drive specific automated alarms based on machine conditions. Each output integrates \u003cstrong\u003eAlarm Drive Logic\u003c\/strong\u003e, enabling complex configurations of AND and OR gates utilizing alert and danger inputs aggregated from any combination of monitor channels within the same rack. The module interfaces seamlessly with matching backplane termination boards to trigger safety systems, emergency shutdown mechanisms, or external indicators across various high-criticality rotating assets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour independent, highly configurable relay channels capable of processing individual asset voting logic.\u003c\/li\u003e\n\u003cli\u003eAdvanced \u003cstrong\u003eAlarm Drive Logic\u003c\/strong\u003e supporting combinational AND\/OR structures to optimize protective trip sequences.\u003c\/li\u003e\n\u003cli\u003eFlexible slot placement, allowing installation in any available slot to the right of the Rack Interface Module.\u003c\/li\u003e\n\u003cli\u003eComprehensive front-panel diagnostic indicators displaying operation health (OK), active rack communications (TX\/RX), and independent channel alarm states.\u003c\/li\u003e\n\u003cli\u003eOnboard arc suppressors equipped as standard to safely mitigate electrical surges across output loads.\u003c\/li\u003e\n\u003cli\u003eProgrammed easily via the specialized software utility to match specialized system criteria.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed turbomachinery and compressor protection loops.\u003c\/li\u003e\n\u003cli\u003eAutomated safety logic gating for power generation equipment and industrial pumps.\u003c\/li\u003e\n\u003cli\u003eInterfacing critical condition indicators with Distributed Control Systems (\u003cstrong\u003eDCS\u003c\/strong\u003e) and Emergency Shutdown Systems (\u003cstrong\u003eESD\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eMulti-channel vibration monitoring frameworks where logical voting criteria prevent false process trips.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number \/ Option Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/32-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel Relay Module complete assembly configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel Relay I\/O Module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: None.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: CSA\/NRTL\/C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125712-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpare Parts:\u003c\/strong\u003e Spare 4-Channel Relay Module.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125720-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpare Parts:\u003c\/strong\u003e Spare 4-Channel Relay I\/O Module.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e132319-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpare Parts:\u003c\/strong\u003e Firmware IC.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00580436\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpare Parts:\u003c\/strong\u003e Connector Header, Internal Termination, 6-position, Green.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpare Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e125712-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo single-pole, double-throw (SPDT) relays connected in a double-pole, double-throw (DPDT) configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Sealing Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArc Suppressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms, installed as standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 cycles @ 5 A, 24 Vdc or 120 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Operation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-selectable for Normally De-energized or Normally Energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistive Switched Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax dc: 120 W | Max ac: 600 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Switched Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Switched Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003edc: 30 Vdc | ac: 250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (1.6 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Slot Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot for Main Module, 1 full-height rear slot for I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe interface configurations provide dedicated diagnostic readouts and contact terminals for reliable loop signaling:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel indicator; remains illuminated when the internal circuit functions properly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTX\/RX LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel indicator; flashes continuously to show normal rack backplane communication activity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH ALARM LEDs (1 - 4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent indicators; illuminate directly when the corresponding relay channel triggers an alarm state.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear board wire connection blocks used to tie contact points to plant automation systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnboard control mechanisms used to define the base operational state of output contacts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Positioning:\u003c\/strong\u003e Slide the component into a single full-height front slot of the master enclosure, placing it to the right of the primary interface card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Mitigation:\u003c\/strong\u003e Prior to touching or handling the circuit boards, secure an approved anti-static grounding wrist strap to reduce risk from unintended electrostatic discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Mapping:\u003c\/strong\u003e Open the custom utility framework to establish targeted trip maps before testing the system output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eState Selection:\u003c\/strong\u003e Manually position the physical configuration switches to select Normally Energized or Normally De-energized states before commissioning the output relay loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTMR Exclusion:\u003c\/strong\u003e Note that standard four-channel options are not suited for Triple Modular Redundant loops; apply the correct dedicated voting assembly model for TMR protection architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Emissions:\u003c\/strong\u003e EN50081-2, EN 55011 Class A (Conducted and Radiated Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity:\u003c\/strong\u003e EN50082-2, EN 61000-4-2 (ESD Criteria B), ENV 50140 (Radiated Susceptibility Criteria A), ENV 50141 (Conducted Susceptibility Criteria A), EN 61000-4-4 (EFT Criteria B), EN 61000-4-5 (Surge Criteria B), EN 61000-4-8 (Magnetic Field Criteria A), EN 61000-4-11 (Power Supply Dip Criteria B), ENV 50204 (Radio Telephone Criteria B).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Directives:\u003c\/strong\u003e EN 61010-1 Safety Requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Standards:\u003c\/strong\u003e CSA\/NRTL\/C Class I, Division 2, Groups A through D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the distinct difference between this spare and a standard 3500\/32 ordering code?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/32 describes the general functional family or multi-component system configuration while the distinct part number defines the individual hot-swappable front card provided as a component replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan these relay channels be manually assigned to alarms on any vibration monitor card inside the same system frame?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the internally stored processing algorithm pulls operational signals and alarm states from any combination of standard slots across the active rack configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I adjust a relay channel between Normally Energized and Normally De-energized behaviors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe target configuration requires the adjustment of individual physical hardware switches located on the assembly alongside parameter adjustments inside the configuration utility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes a standard 125712-01 component ship with its matching rear input\/output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this part number specifically designates the front-facing main processor card alone; if the rear termination board is needed, it must be ordered under its individual product number.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847658347,"sku":"3500\/32 125712-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-32-125712-01-4-channel-relay-module-apgs2pgvaqc_1bd7426c-4cca-42dc-afd3-fce09079cbbe.jpg?v=1765448967"},{"product_id":"bently-nevada-330180-x1-cn-mod-145004-81-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-CN MOD 145004-81 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL Proximitor Sensor from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a DIN mount signal conditioning module used in 5 mm and 8 mm proximity transducer systems for industrial machinery protection. It processes eddy current probe signals into stable vibration and shaft position outputs for turbines, compressors, generators, and heavy rotating equipment operating in refinery, petrochemical, and power generation environments where continuous condition monitoring is critical to prevent mechanical failure.\u003c\/p\u003e\n\u003cp\u003eThis configuration includes MOD 145004-81 calibration data and is specifically engineered for SNCM 439 target material applications, commonly used in high-strength industrial shaft systems such as Hitachi machinery packages. The DIN rail mounting structure (X1 modification) enables compact installation inside control cabinets, reducing wiring complexity while maintaining stable signal integrity under electrical noise, vibration, and thermal variation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330180\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor base model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry specific hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD 145004-81\u003c\/td\u003e\n\u003ctd\u003eCalibration and configuration dataset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT-0733\u003c\/td\u003e\n\u003ctd\u003eTarget calibration reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJob 162285\u003c\/td\u003e\n\u003ctd\u003eApplication specific configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial SNCM 439\u003c\/td\u003e\n\u003ctd\u003eTarget shaft material calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemark\u003c\/td\u003e\n\u003ctd\u003eHitachi only application specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 330180-X1-CN module is designed as part of the 3300 XL proximity measurement chain, interfacing with 5 mm and 8 mm proximity probes and extension cables.\u003c\/p\u003e\n\u003cp\u003eIt performs signal conditioning, demodulation, and linearization of eddy current-based displacement signals. The DIN rail architecture allows direct integration into industrial control cabinets and protection systems, ensuring stable operation in environments with high electromagnetic interference and continuous vibration exposure.\u003c\/p\u003e\n\u003cp\u003eTarget material calibration is critical in this configuration, ensuring accurate measurement response when used with SNCM 439 alloy shafts, commonly found in high-performance rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X1-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail (X1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eMOD 145004-81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eSNCM 439\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Reference\u003c\/td\u003e\n\u003ctd\u003eCT-0733\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJob Number\u003c\/td\u003e\n\u003ctd\u003e162285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5 mm and 8 mm probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC system supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery vibration and shaft position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs 330180-X1-CN compatible with standard 3300 XL probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is fully compatible with both 5 mm and 8 mm 3300 XL proximity probes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does MOD 145004-81 indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt represents a factory calibration and configuration dataset specific to target material SNCM 439 applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is SNCM 439 material specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt ensures accurate calibration for high-strength industrial shaft materials used in heavy machinery systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in general industrial applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is primarily designed for application-specific systems, especially Hitachi machinery configurations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Engineering Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module on a properly grounded DIN rail inside a vibration-isolated control cabinet to ensure signal stability.\u003c\/p\u003e\n\u003cp\u003eMaintain strict separation between probe signal wiring and high-power VFD or motor cables to prevent electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eVerify calibration parameters (MOD 145004-81) before commissioning to ensure correct target material response.\u003c\/p\u003e\n\u003cp\u003eEnsure cabinet thermal management keeps operating conditions within specified limits to avoid signal drift.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668317925739,"sku":"145004-81","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/mod145004-81-nsngaptzanv_c2e44692-f942-4f9e-8780-32b8a44ba1d4.jpg?v=1765521087"},{"product_id":"bently-nevada-330195-02-12-10-cn-3300-xl-8-mm-extended-temperature-range-etr-reverse-mount-probe","title":"Bently Nevada 330195-02-12-10-CN 3300 XL 8 mm Extended Temperature Range (ETR) Reverse Mount Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330195-02-12-10-CN is a specialized 8 mm eddy current proximity probe part of the 3300 XL Extended Temperature Range (ETR) series. This transducer is specifically engineered for reverse mount applications where the probe must be installed from the interior of a machine housing or through a probe sleeve. The ETR version is rated for significantly higher operating temperatures than standard probes, making it the primary choice for monitoring radial vibration and axial position in steam turbines, gas turbines, and other high-heat rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThis specific model features a 3\/8-24 UNF thread and is configured with a 1.0-metre (3.3 feet) total cable length. The \"CN\" suffix denotes compliance with country-specific hazardous area certifications, including NEPSI approvals for the Chinese market. When integrated with a 3300 XL ETR extension cable and Proximitor sensor, the system delivers a stable linear scale factor of 7.87 V\/mm (200 mV\/mil) even under extreme thermal cycling conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330195-02-12-10-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm ETR Reverse Mount Proximity Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReverse Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc™\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (NEPSI \/ China Specific)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +260°C (-31°F to +500°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.323 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eReverse mount probes are distinct from standard mount probes in their mechanical housing. Ensure the part number matches the internal machine clearances and the corresponding Proximitor sensor calibration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330195\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm ETR Reverse Mount Probe, 3\/8-24 UNF thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Option: 8 mm ETR Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-12\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector and Cable Option: Miniature coaxial ClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length Option: 1.0 metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval Option: NEPSI \/ China specific approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eReverse Mount Considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike standard probes, the 330195 series is designed to be threaded into a housing from the \"back.\" This is typically required when using Bently Nevada probe housing assemblies or when internal machine space prevents standard front-side access. Ensure that the internal cable routing does not exceed the minimum bend radius of 25.4 mm (1.0 in) to prevent coaxial signal degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Expansion Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Extended Temperature Range (ETR) probes are designed for environments up to 260°C (500°F). When gapping the probe at ambient temperature, engineers must account for the thermal expansion of the machine shaft and housing. Failure to calculate the \"hot gap\" can result in the probe tip making contact with the shaft (rubbing) or moving out of the linear range during operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Integrity in High-Heat Zones:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1.0-metre integral cable is rated for the same temperature as the probe tip. However, where the cable exits the high-temperature zone and connects to the extension cable, the ClickLoc™ junction should be housed in a dry, protected location. Use of silicone connector protectors is mandatory in oil-mist environments to prevent fluid \"wicking\" into the coaxial core, which causes signal drift.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain a single-point ground. The coaxial shield should be grounded only at the Proximitor end (usually at the monitor rack). In high-interference environments typical of gas turbine halls, ensure the extension cable is routed through a dedicated, grounded conduit to maintain a high signal-to-noise ratio.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use a standard 3300 XL extension cable with this ETR probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While they are physically compatible, for maximum accuracy at high temperatures, you must use a 3300 XL ETR extension cable. Standard cables may not withstand the heat or provide the necessary temperature compensation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify the gapping on a reverse-mount probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Use a digital voltmeter at the Proximitor output terminals. For a 3300 XL system, the mid-range gap is typically reached at -10.0 Vdc. Adjust the probe position within the reverse mount sleeve until this value is stabilized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates a temperature-related probe failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: If the DC gap voltage drifts significantly as the machine warms up, but the shaft position is known to be stable, the sensing coil or the coaxial junction may be failing due to thermal stress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between standard \"02\" and \"CN\" approvals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Functionally, the probes are identical. The \"CN\" version is specifically labeled and documented to meet the regulatory import and safety requirements of the People's Republic of China (NEPSI).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318286187,"sku":"330195-02-12-10-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330195-02-12-10-cn-3pymyxlta3z_2a284877-f821-4717-b103-ab6887ce96a3.jpg?v=1765521099"},{"product_id":"bently-nevada-330101-00-25-10-02-cn-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-25-10-02-CN 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-25-10-02-CN is a high-precision 8 mm eddy current proximity probe, a core component of the 3300 XL Transducer System. This system is designed for non-contacting displacement measurements on critical rotating machinery, providing vital data for vibration monitoring, radial position, and axial thrust analysis. It is fully compliant with API 670 standards for machinery protection.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features a 3\/8-24 UNF thread, a 2.5-inch overall case length, and is supplied without stainless steel armor. The assembly includes a 1.0-metre (3.3 feet) integral cable terminated with a miniature coaxial ClickLoc connector. The \"CN\" suffix denotes country-specific agency approvals, primarily NEPSI, for hazardous area installations within the People's Republic of China. When integrated into a complete loop with a 3300 XL extension cable and Proximitor sensor, it delivers a linear scale factor of 7.87 V\/mm (200 mV\/mil).\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-25-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Proximity Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (NEPSI \/ China Specific)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully sealed tip; resistant to water and oil\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eAccurate identification of the probe configuration is essential for system compatibility. The part number 330101-00-25-10-02-CN is derived from the following option codes:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector\/Cable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEPSI \/ China specific approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Calibration and Total Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe is an inductive component within a tuned resonant circuit. This 1.0-metre probe must be paired with an extension cable to reach the required total system length (typically 5.0 or 9.0 metres) as calibrated for the Proximitor sensor. Using a mismatched total loop length will cause significant scale factor errors and zero-point drift.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting Clearances:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo ensure a linear output and prevent \"side-view\" interference, a minimum side clearance of 13 mm (0.5 in) from metallic surfaces must be maintained around the probe tip. If installing through a mounting bracket, ensure the bracket is rigid enough to avoid resonance frequencies within the machine's operating range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGap Setting and Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe should be gapped at the electrical center of its linear range. For a 3300 XL system, the nominal mid-range gap is 1.27 mm (50 mils), which typically corresponds to a DC voltage output of -10.0 Vdc at the Proximitor sensor's \"OUT\" terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc coaxial connector is sensitive to moisture and lubricant ingress. In oil-mist environments (common in bearing housings), it is mandatory to use the connector protector or oil-resistant heat-shrink tubing to prevent signal \"spiking\" or low insulation resistance faults.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this probe be used with a legacy (non-XL) 3300 Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While physically compatible, the 3300 XL series has a different temperature compensation profile and scale factor stability. For maximum accuracy and API 670 compliance, always match 3300 XL probes with 3300 XL Proximitors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates a faulty ClickLoc connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: High-frequency noise or intermittent \"Not OK\" status in the vibration monitor often indicates a loose or contaminated coaxial connection. Inspect the center pin for continuity and ensure the junction is dry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle a \"Material Error\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Standard probes are calibrated for AISI 4140 steel targets. If the target shaft is a different alloy, the scale factor (V\/mm) will change. This requires a software-based scale factor adjustment or a Material Correction Factor (MCF).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the \"CN\" approval functionally different from standard approvals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \"CN\" suffix ensures the unit carries the NEPSI markings required by Chinese regulatory authorities for explosive atmospheres. The electrical and mechanical performance remains identical to standard 3300 XL probes.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318318955,"sku":"330101-00-25-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-25-10-02-cn-o15jtrnz0a3_50ae2112-bc75-415e-a02b-019f51b4dc81.jpg?v=1765521100"},{"product_id":"bently-nevada-330101-00-25-10-02-00-3300-xl-8-mm-proximity-probes-metric","title":"Bently Nevada 330101-00-25-10-02-00 | 3300 XL 8 mm Proximity Probes, Metric","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-25-10-02-00 is an 8 mm eddy current proximity probe belonging to the 3300 XL series. This transducer is designed for non-contacting displacement and vibration measurements in critical machinery protection systems (TSI). It is a standard component of the 3300 XL Proximity Transducer System, used to monitor radial shaft vibration, axial position, and speed on high-speed rotating equipment such as steam turbines, centrifugal compressors, and motors.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration utilizes a 3\/8-24 UNF thread with a 2.5-inch overall case length and is supplied without stainless steel armor. The assembly features a 1.0-metre (3.3 feet) integral cable terminated with a miniature coaxial ClickLoc™ connector. It provides a linear range of 2.0 mm (80 mils) and a standard scale factor of 7.87 V\/mm (200 mV\/mil) when paired with the corresponding 3300 XL Proximitor sensor and extension cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330101-00-25-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 Metre (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot Required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis assembly is defined by its alphanumeric suffix codes. Procurement and engineering teams must verify all parameters to ensure mechanical fit and electrical compatibility with the system loop.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnthreaded Length: 0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall Case Length: 2.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Length: 1.0 Metre (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc™ connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval: Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Loop Integrity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe is a component of a tuned resonant circuit. This 1.0-metre probe must be paired with an extension cable to reach the required total system length (typically 5.0 or 9.0 metres) as calibrated for the Proximitor sensor. Using a mismatched total length will cause significant scale factor errors and non-linearity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installing the 3\/8-24 UNF threads, do not exceed the maximum torque of 13.5 N·m (120 in·lb). Over-torquing can lead to case distortion or internal sensing coil damage. For radial vibration monitoring, ensure the probe tip has a minimum side clearance of 13 mm (0.5 in) from surrounding metallic surfaces to prevent signal interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring and Grounding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc™ connector must be kept clean and dry. In oil-mist environments, it is mandatory to use a connector protector or silicone heat-shrink tubing to prevent lubricant ingress. The coaxial cable shield should be grounded only at the monitor\/Proximitor end to prevent ground loops that introduce 50\/60 Hz noise into the signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Precautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen replacing legacy 3300 probes (non-XL) with 3300 XL series probes, verify the Proximitor sensor is also upgraded to the 3300 XL series. While physically compatible, the XL series has a different temperature compensation profile and scale factor stability.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this 1.0m probe be used as a standalone sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. A 1.0-metre probe is designed to connect to an extension cable. The Proximitor sensor requires the total loop impedance of the specified system length (5m or 9m) to function.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates a faulty ClickLoc connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: High-frequency \"spiking\" or an unstable DC gap voltage typically indicates a loose or contaminated coaxial connection. Clean the contacts with an approved electronic cleaner and ensure the connector is dry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify the DC gap voltage for a 3300 XL system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For most applications, the nominal mid-range gap is 1.27 mm (50 mils), which corresponds to approximately -10.0 Vdc at the Proximitor output terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the impact of target material on calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Standard probes are calibrated for AISI 4140 steel. If the target shaft is a different alloy, the scale factor will change, requiring a Material Correction Factor (MCF) adjustment in the monitoring software.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318351723,"sku":"330101-00-25-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-25-10-02-00-kyxwvwtr0nr_268b1358-092e-4668-9dad-d1768226f631.jpg?v=1765521102"},{"product_id":"bently-nevada-330173-00-03-10-02-cn-3300-5mm-proximity-transducer","title":"Bently Nevada 330173-00-03-10-02-CN 3300 5mm Proximity Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330173-00-03-10-02-CN is a 5mm eddy current proximity transducer belonging to the 3300 series. This transducer is specifically engineered for applications where physical space constraints prevent the use of standard 8mm probes. It is primarily utilized in the monitoring of fluid-film bearing machines, including small turbines, compressors, and pumps, to measure radial vibration, axial thrust, and eccentricity.\u003c\/p\u003e\n\u003cp\u003eThe 5mm system is designed to provide a standard scale factor of 7.87 V\/mm (200 mV\/mil) when paired with a compatible 3300 XL Proximitor sensor and extension cable. This specific configuration features an M8 x 1 metric thread, a 30mm overall case length, and a 1.0-metre total cable length. The \"CN\" designation indicates compliance with country-specific hazardous area certifications, including NEPSI approvals for the Chinese market. It utilizes the Miniature coaxial ClickLoc™ connector to ensure signal stability in high-vibration environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330173-00-03-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5mm Proximity Transducer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM8 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc™\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (NEPSI \/ Hazardous Area)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 psi (4.8 bar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe part number is defined by specific mechanical and electrical options. Procurement must ensure suffix compatibility with the installed Proximitor and machine casing depth.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330173\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 5mm Transducer, M8 x 1 thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCase Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector\/Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChina specific approvals (NEPSI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Clearance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDue to the 5mm tip diameter, this transducer has a smaller linear range than 8mm probes. Maintain a minimum side clearance of 7.6 mm (0.3 in) from surrounding metallic surfaces to prevent signal distortion. When installing in an M8 x 1 tapped hole, do not exceed the maximum torque of 4.5 N·m (40 in·lb) to avoid damaging the sensor tip or the internal sensing coil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration and Loop Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 330173-00-03-10-02-CN is a 1.0-metre transducer. It must be paired with an extension cable (e.g., 4.0m or 8.0m) to reach the required total system length (5m or 9m) as specified by the Proximitor sensor. Using a mismatched total loop length will cause significant errors in the scale factor and DC gap voltage readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProper signal integrity relies on the coaxial cable shield being grounded at the monitor end only. Ensure the probe body is electrically bonded to the machine casing but that the cable shield remains isolated at the transducer end to prevent ground loops. In high-EMI environments, ensure the extension cable is routed through a dedicated grounded conduit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Care:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc™ connector must be kept clean and dry. In oil-mist environments, it is mandatory to use the connector protector or silicone heat-shrink tubing to prevent lubricant ingress into the coaxial junction, which can lead to signal \"spiking\" or false trips.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a 3300 5mm transducer be used with a 3300 XL Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the Proximitor is specifically calibrated for the 5mm probe. Using a Proximitor calibrated for an 8mm probe will result in incorrect vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the \"CN\" approval?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"CN\" suffix confirms that the product meets the legal regulatory requirements for hazardous area installations within China (NEPSI). It is functionally identical to the standard version but includes specific labeling and documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle unstable DC gap voltages during commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This often indicates a loose ClickLoc connector or a damaged cable. Check for continuity and ensure the connector is dry. Also, verify that the target material is AISI 4140 steel, as other alloys will shift the DC gap curve.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318384491,"sku":"330173-00-03-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330173-00-03-10-02-cn-tc1uqcz4gqo_e88bdad5-ee2f-4651-a1f9-0a133e3fa7f0.jpg?v=1765521103"},{"product_id":"bently-nevada-330103-00-03-10-02-cn-3300-xl-proximity-probe","title":"Bently Nevada 330103-00-03-10-02-CN 3300 XL Proximity Probe","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330103-00-03-10-02-CN is an 8 mm eddy current proximity probe part of the 3300 XL series. This transducer is engineered for non-contacting displacement and vibration measurements in critical machinery applications, including steam and gas turbines, centrifugal compressors, and industrial pumps. The 3300 XL system provides an advanced scale factor of 7.87 V\/mm (200 mV\/mil), offering high-fidelity data for radial vibration, axial position, and speed measurements.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features a 3\/8-24 UNF thread with a 0.3-inch overall case length and is supplied without stainless steel armor. The assembly includes a 1.0-metre (3.3 feet) integral cable terminated with a miniature coaxial ClickLoc™ connector. The \"CN\" suffix indicates compliance with country-specific hazardous area certifications, including NEPSI approvals for the Chinese market. It is designed to operate within the 3300 XL Proximitor® sensor loop for reliable machinery protection and diagnostic monitoring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-03-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc™\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (Country Specific \/ NEPSI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis assembly is defined by its alphanumeric suffix codes. Procurement and engineering teams must verify all parameters to ensure mechanical fit and electrical compatibility with the system loop.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330103\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length: 0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length: 0.3 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length: 1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval: Country specific (e.g., NEPSI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting and Clearance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 330103 probe must be mounted in a rigid bracket to prevent false vibration readings caused by bracket resonance. Ensure a minimum side clearance of 13 mm (0.5 in) from metallic surfaces surrounding the probe tip to maintain the 7.87 V\/mm scale factor. When installing the 0.3-inch case, use a torque wrench to ensure the 3\/8-24 UNF threads do not exceed 13.5 N·m (120 in·lb) to prevent case distortion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Calibration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe is a component of a tuned resonant circuit. This 1.0-metre probe must be paired with the correct length of extension cable (e.g., 4.0 m or 8.0 m) to reach the required 5.0-metre or 9.0-metre total system length calibrated for the Proximitor® sensor. Deviation from the specified total length will result in significant sensitivity errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring and Shielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe coaxial ClickLoc™ connector must be protected from environmental contamination. For internal machine applications, use oil-resistant heat-shrink tubing or connector protectors to prevent moisture and lubricant ingress. The shield of the extension cable must be grounded at the monitor end only to prevent ground loops that introduce 50\/60 Hz noise into the vibration signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Material Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard calibration is performed using AISI 4140 steel. If the target shaft is composed of different materials (e.g., stainless steel or chrome-plated shafting), a Scale Factor Error will occur. Technical staff must apply a Material Correction Factor within the monitoring system configuration to ensure accurate displacement readings.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this 1.0m probe be used as a standalone sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. A 1.0-metre probe must be connected to an extension cable. The Proximitor® requires a specific total loop impedance (5m or 9m) to maintain its linear output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates a faulty ClickLoc connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Signal \"spiking\" or high-frequency noise in the monitor usually indicates a loose or contaminated coaxial connection. Inspect the center pin for continuity and ensure the connector is dry and free of metallic debris.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify the DC gap voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For a 3300 XL system, the nominal mid-range gap voltage is -10.0 Vdc. Use a voltmeter at the Proximitor terminals during installation to set the physical gap until this voltage is achieved.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this probe compatible with older 3300 series monitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, 3300 XL probes are generally backward compatible with 3300 systems, but it is recommended to use 3300 XL Proximitor sensors to take full advantage of the improved scale factor and temperature stability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318417259,"sku":"330103-00-03-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-00-10-10-02-cn-extension-cable-gcvwrdoz53m_77ce8065-4b50-4c36-b5ba-03af14d6511e.jpg?v=1765449495"},{"product_id":"bently-nevada-21000-28-05-00-047-04-02-proximity-probe-housing-assembly","title":"Bently Nevada 21000-28-05-00-047-04-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 21000-28-05-00-047-04-02 is an external mounting Proximity Probe Housing Assembly designed to facilitate the installation of proximity transducers through machine casings. It is a primary component for Turbine Supervisory Instrumentation (TSI) systems, allowing for the adjustment or replacement of probes without disassembling the machine. The assembly provides environmental protection for the probe and maintains a seal against machine internal pressure.\u003c\/p\u003e\n\u003cp\u003eThis specific 21000 series configuration includes an integrated 3300 XL 8 mm proximity probe with multiple agency approvals and a 0.5-metre (20 in) integral cable. The housing is specified with a 4.7-inch probe penetration depth and a 3\/4-14 NPT mounting thread. It is commonly utilized in power generation and petrochemical industries for monitoring radial vibration and axial thrust on steam turbines, compressors, and large gearboxes where external accessibility to the transducer is required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21000-28-05-00-047-04-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probe Housing Assemblies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm (Multiple Approvals)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Metre (20 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandoff Adapter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e00 (None)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Penetration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.7 Inches (Code 047)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFittings Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne 3\/4-14 NPT plug only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/4-14 NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAluminum (Standard) or Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F) for Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis assembly is configured based on specific application requirements. Ensure the penetration depth and mounting threads match the machine casing specifications.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e21000\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Mounting Proximity Probe Housing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-28\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm probe, Multiple Approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 metre (20 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandoff Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-047\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePenetration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.7 inches\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFittings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne 3\/4-14 NPT plug only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/4-14 NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Alignment and Gapping:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 21000 housing allows for the probe to be gapped externally. During installation, the probe is threaded into the sleeve until it reaches the target. It must then be backed off to achieve the desired DC gap voltage (typically -10.0 Vdc for 3300 XL systems). Once gapped, the locknut must be secured to prevent the probe from moving due to machine vibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Sealing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3\/4-14 NPT mounting thread must be treated with a high-quality thread sealant to ensure a leak-proof connection with the machine casing. If the machine utilizes high-pressure lubricants or is under vacuum, verify the integrity of the O-rings within the housing assembly during routine maintenance intervals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 0.5-metre integral cable is terminated with a miniature coaxial ClickLoc connector. This connector should be housed within the terminal head of the 21000 assembly. Ensure the cable is not pinched when closing the housing cover. Use the provided 3\/4-14 NPT plug for unused conduit entries to maintain the environmental rating of the enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Precautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen replacing a probe within the 21000 housing, ensure the replacement probe matches the \"Total Length\" of the original system (typically 5m or 9m total). This 0.5m probe requires a specific extension cable to reach the Proximitor sensor. Using mismatched lengths will lead to calibration errors in the vibration monitor.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I change the penetration depth in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The penetration depth (047 = 4.7 inches) is factory-set based on the internal sleeve and probe length. Attempting to modify this will compromise the mechanical limits and gapping capability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What if oil is leaking from the housing head?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This indicates a failure of the internal seal or O-ring between the probe sleeve and the housing body. Inspect the O-rings for degradation or hardening and replace them with authentic Bently Nevada seal kits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I identify a grounding issue with the 21000 housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: If the vibration signal shows 50\/60 Hz interference, verify that the housing is electrically bonded to the machine casing and that the cable shield is only grounded at the Proximitor\/Rack end to avoid ground loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 3300 XL probe inside the housing replaceable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The probe is a discrete component (-28 option). However, it is highly recommended to replace the probe with the exact same option code to maintain the hazardous area certifications associated with the assembly.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318450027,"sku":"21000-28-05-00-047-04-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-21000-28-05-00-047-04-02-proximity-probe-housingassemblies-i0wr22qjvp4_c6596c84-1084-4307-9e8a-4ce8b22f459d.jpg?v=1765446987"},{"product_id":"bently-nevada-330904-xx-xx-10-02-cn-158268-00-34-3300-nsv-proximity-probe","title":"Bently Nevada 330904-XX-XX-10-02-CN (158268-00-34) 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330901-XX-XX-10-02-CN (Engineering Part Number 158268-00-34) is an eddy current proximity transducer belonging to the 3300 NSv series. The NSv (Narrow Side View) system is specifically designed for applications where standard 8 mm probes cannot be used due to physical space constraints or tight mounting clearances. It is predominantly used for vibration and position monitoring on small-diameter shafts or within machinery with restricted internal access, such as centrifugal compressors, high-speed pumps, and aeroderivative turbines.\u003c\/p\u003e\n\u003cp\u003eThis specific model features an M8 x 1 metric thread and is equipped with stainless steel armor for enhanced mechanical protection of the coaxial cable. The 1.0-metre total length assembly is terminated with a miniature coaxial ClickLoc connector. The \"CN\" suffix confirms adherence to country-specific hazardous area approvals, including NEPSI certification for the Chinese market. It provides a linear output when paired with a matched 3300 NSv Proximitor Sensor.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330904-XX-XX-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEngineering Part No.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e158268-00-34\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM8 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWith Stainless Steel Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (39 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (NEPSI\/Hazardous Area)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eIndustrial procurement should reference both the model number and the engineering part number to ensure exact configuration matching.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330904-XX-XX-10-02-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e158268-00-34\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Probe, M8 x 1, Armor, 1.0m Length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Clearance Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv series is designed to reduce the \"side-view\" effect; however, a minimum clearance from surrounding metal is still required to maintain linearity. Ensure the probe tip is not recessed into the mounting bracket. For M8 x 1 threads, the recommended mounting torque is 4.5 N·m (40 in·lb) to prevent case distortion or thread damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection (Armor):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model is supplied with stainless steel armor. The armor protects the coaxial core from abrasion and crushing; however, it is not fluid-tight. In environments with heavy oil or chemical exposure, ensure the armored cable is further protected or routed such that liquids cannot migrate into the ClickLoc connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProper signal integrity relies on a single-point ground. The shield of the extension cable should be grounded at the Proximitor end (usually in the monitor rack or local junction box). Ensure the probe armor does not inadvertently ground at the machine casing if the system design requires isolated grounds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Precautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 158268-00-34 is a specific engineering configuration. When replacing an existing probe, verify the unthreaded and overall case length (marked as XX-XX in the ordering string) to ensure the probe tip reaches the target shaft without mechanical interference.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 3300 NSv probe be used with a standard 3300 XL Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The 3300 NSv probe must be paired with a 3300 NSv Proximitor. The internal sensing coil and frequency response of the NSv series differ from the 3300 XL series, and mixing them will result in significant measurement errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the ClickLoc connector protector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The protector prevents the miniature coaxial connector from loosening due to machine vibration and prevents environmental contaminants (dust\/oil) from entering the signal path. It should always be installed and seated correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle unstable DC gap voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Unstable gap voltage often indicates a loose connection at the ClickLoc junction or moisture ingress. Disconnect the cable, clean the contacts with an approved electronic cleaner, and dry thoroughly before reconnecting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the target material calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Standard Bently Nevada proximity probes are calibrated for AISI 4140 steel. If the target shaft is a different alloy, the scale factor (V\/mm) will change, requiring a software scale factor adjustment in the monitoring system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318482795,"sku":"330904-XX-XX -10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330904-xx-xx-10-02-cn-wqkn2jbrtsd_efaefd85-80ff-4ee4-869a-7091b6f00dca.jpg?v=1765521106"},{"product_id":"bently-nevada-330101-00-24-05-02-00-3300-xl-proximity-probe","title":"Bently Nevada 330101-00-24-05-02-00 3300 XL Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-24-05-02-00 is a high-precision 8 mm eddy current proximity probe part of the 3300 XL series. This transducer is engineered for non-contacting displacement measurements in critical rotating machinery, providing essential data for vibration monitoring, radial position, and axial thrust analysis. It is compatible with 3300 XL Proximitor Sensors and is widely utilized in the monitoring of steam turbines, centrifugal compressors, and industrial pumps.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features a 3\/8-24 UNF thread with a 2.4-inch overall case length and is supplied without stainless steel armor. The assembly includes a 0.5-metre (1.6 feet) integral cable terminated with a miniature coaxial ClickLoc connector. Designed to operate under extreme industrial conditions, the probe maintains a linear scale factor of 7.87 V\/mm (200 mV\/mil) when paired with the appropriate 3300 XL extension cable and Proximitor.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-24-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.4 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Metre (1.6 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eAccurate identification of the probe configuration is essential for system compatibility. The part number 330101-00-24-05-02-00 is derived from the following option codes:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length: 0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-24\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length: 2.4 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length: 0.5 metre (1.6 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval: Not required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration and Loop Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe is a component of a tuned resonant circuit. This 0.5-metre probe must be used with a 4.5-metre or 8.5-metre extension cable to reach the required 5.0-metre or 9.0-metre total system length. Using a total length that deviates from the Proximitor's calibrated specification will result in an incorrect Scale Factor (SSF) and non-linear output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installing the 3\/8-24 UNF probe through the machine casing, ensure the mounting bracket is rigid to avoid resonance. Tighten the probe to a maximum torque of 13.5 N·m (120 in·lb). Exceeding this limit can cause case distortion or damage to the internal sensing coil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGap Setting:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe should be gapped at the mechanical center of its linear range. For a 3300 XL system, the nominal mid-range gap is 1.27 mm (50 mils), which typically corresponds to a DC voltage output of -10.0 Vdc from the Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector (-02) is designed for secure coupling but remains sensitive to environmental contamination. For internal machine applications, the use of connector protectors or oil-resistant heat-shrink tubing is recommended to prevent moisture or lubricant ingress, which can lead to signal \"spiking\" or drift.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this probe with a standard 3300 (non-XL) Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While 3300 XL probes are physically compatible, the 3300 XL system has a different scale factor and temperature compensation profile. For maximum accuracy, it is recommended to use 3300 XL Proximitor sensors with 3300 XL probes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates a faulty ClickLoc connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: High-frequency noise or \"spiking\" in the vibration signal often indicates a loose or contaminated coaxial connection. Check the center pin for continuity and ensure the connector is dry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 0.5m length sufficient for my installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 0.5-metre probe is typically used when the connection to the extension cable occurs inside the machine or a nearby junction box. Ensure the total length (probe + extension cable) matches your specific Proximitor model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this probe require a safety barrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Since this model is \"Not Required\" (Option 00) for agency approvals, it does not carry intrinsic safety certifications. If the installation area is classified as hazardous, a probe with the appropriate approval code (e.g., -05 for multi-approvals) must be selected.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318548331,"sku":"330101-00-24-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-24-05-02-00-ajtyggij1xx_d67f1f3a-9448-457d-8f8d-c2fabc603500.jpg?v=1765521108"},{"product_id":"bently-nevada-330101-00-30-05-02-00-3300-xl-proximity-probe","title":"Bently Nevada 330101-00-30-05-02-00 3300 XL Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-30-05-02-00 is a high-performance 8 mm eddy current proximity probe belonging to the 3300 XL series. This transducer is a primary component for vibration monitoring, radial position, and axial thrust measurement in critical rotating machinery, including steam turbines, centrifugal compressors, and industrial pumps. Utilizing the eddy current principle, it provides a non-contacting method to observe the target shaft's movement relative to the machine housing.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features a 3\/8-24 UNF thread with a 3.0-inch overall case length and is supplied without stainless steel armor. With a total electrical length of 0.5 metres (1.6 feet), it is intended for internal mounting applications where the probe is installed through a machine casing and connected to an extension cable. The assembly utilizes the ClickLoc miniature coaxial connector, ensuring signal integrity through vibration-resistant coupling.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-30-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Metre (1.6 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Coaxial ClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis assembly is defined by its alphanumeric suffix codes. Procurement and engineering teams must verify all parameters to ensure mechanical fit and electrical compatibility with the system loop.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length: 0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-30\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length: 3.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length: 0.5 metre (1.6 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval: Not required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Clearances:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo ensure a linear output and prevent \"side-view\" interference, a minimum side clearance of 13 mm (0.5 in) from metallic surfaces must be maintained around the probe tip. If installing multiple probes in a single radial bearing plane, maintain a minimum spacing of 40 mm (1.6 in) between probe centers to avoid crosstalk.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Calibration and Cable Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe is part of a tuned system. This 0.5-metre probe must be paired with an extension cable to reach the total system length (typically 5.0 or 9.0 metres) required by the 3300 XL Proximitor Sensor. Using a probe\/cable combination that does not match the Proximitor’s calibrated length will result in significant sensitivity errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector (-02) is designed for reliable signal transmission but is sensitive to environmental contamination. During installation, ensure connectors are free of moisture, oil, and metallic debris. The use of connector protectors or silicone heat-shrink tubing is recommended for internal machine environments to prevent connector loosening due to vibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3\/8-24 UNF threads should be tightened to a maximum torque of 13.5 N·m (120 in·lb). Over-torquing can lead to case distortion or thread stripping, which may compromise the hermetic seal of the probe tip.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this 0.5m probe be used as a standalone sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. A 0.5-metre probe is designed to be connected to an extension cable. The 3300 XL Proximitor requires a total loop length (e.g., 5m or 9m) to function within its linear range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should the DC gap voltage be for a standard installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For a 3300 XL system, the nominal mid-range gap voltage is typically -10.0 Vdc. Set the physical gap during installation to reach this voltage at the Proximitor output for optimal linear range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle a \"Probe Not Found\" or \"Not OK\" status on the monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Check the continuity of the center pin on the ClickLoc connector. Ensure the total resistance of the probe (center to outer conductor) is within factory limits (typically 3.0 to 12.0 ohms depending on cable length).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this probe compatible with the original 3300 system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While 3300 XL probes are generally compatible with older 3300 systems, there may be slight differences in the scale factor. It is best practice to use 3300 XL components throughout the entire signal string.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318581099,"sku":"330101-00-30-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-30-05-02-00-sqwnomiy32m_03c00db5-4d96-4ac2-82af-7f73900aaa47.jpg?v=1765521109"},{"product_id":"bently-nevada-330901-00-90-10-01-cn-3300-nsv-proximity-probe","title":"Bently Nevada 330901-00-90-10-01-CN 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330901-00-90-10-01-CN is a high-precision proximity probe belonging to the 3300 NSv (Narrow Side View) series. This transducer system is specifically engineered for applications with tight physical constraints or where the target surface is small, such as centrifugal compressors, pumps, and small turbines. The NSv series is designed to minimize \"side-view\" effects, allowing the probe to be used in proximity to neighboring metallic surfaces that would interfere with standard 8 mm probes.\u003c\/p\u003e\n\u003cp\u003eThis specific model features a 1\/4-28 UNF thread and is configured with a 9.0-inch overall case length and a 1.0-metre total length. It is supplied without stainless steel armor on the cable and includes a miniature coaxial ClickLoc connector with a connector protector. The \"CN\" suffix indicates compliance with ATEX\/IECEx and Chinese NEPSI hazardous area standards, making it suitable for global and domestic Chinese industrial projects.\u003c\/p\u003e\n\u003ch3\u003eHardware Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330901-00-90-10-01-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4-28 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (39 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc with protector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX, IECEx, NEPSI (CN)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~150 g (Net) \/ 1.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis part number is generated based on a specific configuration of the 330901 base model. Ensure all suffix codes match existing field documentation before ordering.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330901\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Proximity Probe (1\/4-28 UNF thread)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length: 0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-90\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length: 9.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length: 1.0 Metre (39 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector with protector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX\/IECEx and NEPSI hazardous area markings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Material and Surface Finish:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv system is factory-calibrated for AISI 4140 steel. If the target shaft is made of a different material, the Proximitor sensor output will require recalibration or a scale factor adjustment. The target area should be at least 1.5 times the probe tip diameter (approx. 9.5 mm \/ 0.375 in) to ensure a linear output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Clearances:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NSv series is designed for tight spaces; however, a minimum side clearance of 1.5 mm (0.06 in) from the probe tip to surrounding metallic objects must be maintained to prevent signal distortion. When installing the 9.0-inch case, ensure the probe is not over-torqued into the mounting bracket; recommended torque for 1\/4-28 UNF threads is 2.3 N·m (20 in·lb).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection and Routing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model (-01) is supplied without armor. In environments with high mechanical risk or chemical exposure, the cable should be protected using a dedicated flexible conduit. All coaxial connections must be kept clean and dry. The ClickLoc connector protector must be properly seated to maintain signal integrity and prevent environmental contamination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"CN\" approval code is mandatory for installations within the People's Republic of China requiring NEPSI certification. For global projects, the ATEX and IECEx markings ensure the probe can be used in intrinsically safe (IS) circuits when paired with an approved Proximitor sensor and safety barrier.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a 3300 NSv probe be used with a standard 3300 XL Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. 3300 NSv probes require a dedicated 3300 NSv Proximitor sensor. Using a standard 3300 XL Proximitor will result in incorrect sensitivity and non-linear data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum recommended distance between the probe and Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The total length of the probe plus the extension cable must match the Proximitor sensor’s design (typically 5.0 or 7.0 metres). This specific probe is 1.0 metre; thus, a 4.0 or 6.0 metre extension cable is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I identify a faulty ClickLoc connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: If the vibration signal shows high-frequency \"spiking\" or the DC gap voltage is unstable, inspect the miniature coaxial center pin. Ensure the connector protector is not cracked and that no moisture has entered the junction.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318613867,"sku":"330901-00-90-10-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330901-00-90-10-01-cn-mir0klbszv1_82935524-d760-4f38-a316-3ff7fe45160e.jpg?v=1765521111"},{"product_id":"bently-nevada-24701-28-05-xx-028-04-xx-mod-323933-00-02-proximity-probe-housing-assembly","title":"Bently Nevada 24701-28-05-XX-028-04-XX MOD 323933-00-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 24701-28-05-XX-028-04-XX MOD 323933-00-02 is a specialized Proximity Probe Housing Assembly designed for internal mounting applications within the 3300 XL series vibration monitoring systems. This assembly facilitates the secure installation and environmental protection of an 8 mm proximity probe through the machine casing.\u003c\/p\u003e\n\u003cp\u003eConstructed with a 303 stainless steel body and a 304 stainless steel sleeve, the housing is engineered to withstand high-pressure lubricants and corrosive atmospheres common in steam turbines, centrifugal compressors, and industrial gearboxes. This specific configuration includes a 3300 XL 8 mm probe with multiple hazardous area approvals, a 0.5-metre integral cable, and a 2.8-inch probe penetration depth. The \"MOD\" suffix indicates a custom factory modification (323933-00-02) tailored to specific OEM or end-user engineering requirements, ensuring precise alignment with machine internal clearances.\u003c\/p\u003e\n\u003ch3\u003eHardware Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24701-28-05-XX-028-04-XX MOD 323933-00-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probe Housing Assemblies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e304 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm (Multiple Approvals)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Metre (20 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Penetration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandoff Adapter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFittings Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne 3\/4-14 NPT plug only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModification Info\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMOD 323933-00-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis assembly is configured according to Bently Nevada standard option codes. Procurement should verify all suffix segments to ensure mechanical compatibility.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e24701\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probe Housing Assembly Base Model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-28\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm probe with connector and multiple approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 metre (20 in) probe cable length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-XX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo standoff adapter required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-028\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.8 inch probe penetration depth\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne 3\/4-14 NPT plug\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-XX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo additional options\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMOD 323933-00-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Modified Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Penetration and Air Gap Setting:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2.8-inch penetration depth must be verified against the machine casing thickness and the required standoff from the shaft. Precise air gap adjustment is critical for the linear range of the 3300 XL system. Use a calibrated voltmeter to set the gap voltage (typically -10.0 Vdc for a mid-range gap) before final torquing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSealing and Pressure Integrity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 24701 housing is designed to maintain a seal against machine internal pressure. Ensure the NPT threads are treated with appropriate industrial-grade sealant (e.g., Loctite 567 or equivalent) to prevent oil leakage. Avoid over-torquing the probe within the sleeve, as this can damage the probe tip or the internal threading.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 0.5-metre cable segment is susceptible to mechanical damage during installation. All internal wiring should be secured using stainless steel clips to prevent cable whip or fatigue caused by machine vibration. Use flexible conduit for the external portion of the cable run to the Proximitor Sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Precautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen replacing an existing housing, ensure the MOD 323933-00-02 specification matches the original installation. Standard 24701 units may lack the specific internal clearances or thread modifications present in this MOD version, potentially leading to mechanical interference or seal failure.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a standard 3300 XL probe be used as a replacement within this housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the housing accepts 8 mm probes, the specific probe in this assembly (-28 option) includes multiple approvals and a specialized connector. Always match the probe part number found on the cable tag to ensure electrical compatibility with the Proximitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I identify the specific modification in MOD 323933-00-02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: MOD numbers are internal factory records. This modification typically involves non-standard sleeve lengths, specialized thread pitches, or unique material treatments. Refer to your original machine OEM manual or Bently Nevada data sheet for this MOD code.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the 3\/4-14 NPT plug?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Option -04 provides one plug for unused conduit entries in the housing head. Ensure this is installed and tightened to maintain the IP\/NEMA rating of the assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this housing suitable for high-temperature service?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The stainless steel construction is rated for high temperatures, but the limit is governed by the 3300 XL probe's specifications. Generally, the probe is rated up to 177°C (350°F).\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318646635,"sku":"323933-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/24701-28-05-xx-028-04-xx-mod-323933-00-02-31epxd14pkj_14a9666f-18b1-4087-9b4b-e8db977d8eb0.jpg?v=1765521111"},{"product_id":"330877-080-36-cn-bently-nevada-3300-xl-50-mm-extension-cable","title":"330877-080-36-CN Bently Nevada 3300 XL 50 mm Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN (330877-080-36-CN)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 3300 XL 50 mm extension cable manufactured by Bently Nevada, specifically engineered for critical machinery protection and proximity sensor systems. As a vital component of the 3300 XL 50 mm Proximitor sensor system, this cable maintains signal integrity between the probe and the Proximitor sensor in large-scale rotating equipment. Featuring the specialized FluidLoc technology and PFA insulation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to prevent hazardous fluids from wicking through the cable, making it an essential solution for oil-filled environments such as turbines, compressors, and large industrial pumps in the oil and gas or power generation sectors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a 75 ohm triaxial architecture, insulated with perfluoroalkoxyethylene (PFA) to ensure extreme temperature resilience and chemical resistance. This specific configuration features a cable length of 8.0 meters (26.2 feet) and utilizes the \"36\" FluidLoc option, which provides an additional layer of protection against fluid migration—a common cause of sensor failure in pressurized machinery. The \"CN\" agency approval indicates country-specific compliance, ensuring the hardware meets rigorous safety and technical standards for localized industrial deployments. With a typical capacitance of 69.9 pF\/m, the cable is tuned to maintain the precise electrical characteristics required for accurate vibration and position measurements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330877-080-36-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 50 mm Extension Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 meters (26.2 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm triaxial, PFA insulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor\/Cable Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc technology (Option 36)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +200 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +200 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (Country Specific)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the FluidLoc (Option 36) cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc extension cable is specifically designed with a proprietary internal seal that prevents oil, moisture, or other process fluids from leaking through the inside of the cable. This protects the Proximitor sensor electronics from contamination if a probe seal fails in an oil-filled machine housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 330877-080-36-CN compatible with standard 3300 XL 8 mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This extension cable is specifically designed for the 3300 XL 50 mm system. The electrical characteristics (capacitance and impedance) of 50 mm cables differ from 8 mm or 11 mm systems. Using mismatched cables will result in significant calibration errors and inaccurate machinery vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable withstand extreme high-temperature environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Thanks to the PFA (perfluoroalkoxyethylene) insulation, the cable is rated for continuous operation in temperatures ranging from -51 Celsius to +200 Celsius, making it suitable for mounting inside hot turbine enclosures or near steam lines.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation, ensure the miniature coaxial connectors remain clean and dry. Use a silicone lubricant only on the connector threads if required by the manual, but never on the signal-carrying pins. It is highly recommended to use connector protectors or heat-shrink tubing to seal the connection point between the probe and the extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo avoid damaging the triaxial shielding and the FluidLoc seal, observe the minimum bend radius during routing. Avoid sharp 90-degree bends; instead, use sweeping curves to maintain the 75 ohm impedance and prevent signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRouting and Interference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough grounded metal conduit wherever possible. Avoid running the extension cable parallel to high-voltage AC motor leads or VFD cables, as electromagnetic interference (EMI) can introduce noise into the low-voltage proximity signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318679403,"sku":"330877-080-36-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330877-080-36-cn-aqxqi3pbqbs_b6b0a565-3d1e-4920-94a6-c1ddfde9ed58.jpg?v=1765521112"},{"product_id":"bently-nevada-3500-15-05-05-cn-3500-15-dual-channel-power-supply-module","title":"Bently Nevada 3500\/15-05-05-CN 3500\/15 Dual Channel Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/15-05-05-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3500 Series rack power supply module designed to provide regulated and reliable electrical power for Bently Nevada 3500 machinery protection systems. It is widely used in power plants, oil and gas facilities, and heavy industrial processing units where continuous condition monitoring depends on stable rack-level power delivery.\u003c\/p\u003e\n\u003cp\u003eThis module supports universal AC input and dual-slot redundancy configuration, ensuring uninterrupted operation of critical monitoring systems. The design allows simultaneous installation of two power supplies for redundancy, reducing risk of system shutdown due to single power failure.\u003c\/p\u003e\n\u003cp\u003eThe CN configuration indicates country-specific hazardous area compliance requirements for regulated industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePower Configuration Structure\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3500\/15\u003c\/td\u003e\n\u003ctd\u003e3500 Series power supply module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eUniversal AC input 85 to 264 Vac rms (top slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eUniversal AC input 85 to 264 Vac rms (bottom slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis configuration defines input compatibility and redundancy architecture for rack power distribution.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/15-05-05-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.15 cm x 5.08 cm x 12.07 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified (typical rack module design approx. 2–3 kg system-level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3500 machinery protection system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this power supply redundant?\u003c\/strong\u003e\u003cbr\u003eYes. The 3500\/15 supports dual power supply configuration for redundancy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it operate on global voltage standards?\u003c\/strong\u003e\u003cbr\u003eYes. It supports universal AC input from 85 to 264 Vac.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if one power module fails?\u003c\/strong\u003e\u003cbr\u003eThe system continues operating using the remaining active supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this compatible with all 3500 racks?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with standard Bently Nevada 3500 rack systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eInstall both power supplies in dual configuration when system uptime is critical.\u003c\/p\u003e\n\u003cp\u003eEnsure proper rack grounding to reduce electrical noise and improve system stability.\u003c\/p\u003e\n\u003cp\u003eVerify airflow clearance to maintain thermal stability under high load conditions.\u003c\/p\u003e\n\u003cp\u003eDo not mix incompatible power module revisions within the same rack.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Engineering Guidance\u003c\/h3\u003e\n\u003cp\u003eUse redundant power configuration in turbine protection and compressor monitoring systems.\u003c\/p\u003e\n\u003cp\u003eMaintain stable environmental conditions to extend module lifecycle.\u003c\/p\u003e\n\u003cp\u003eInspect connectors during scheduled maintenance cycles to prevent intermittent power loss.\u003c\/p\u003e\n\u003cp\u003eEnsure correct slot placement to avoid configuration mismatch in rack systems.\u003c\/p\u003e\n\u003ch1\u003e\u003c\/h1\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318712171,"sku":"3500\/15-05-05-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-05-05-cn-tq34mqb1fs4_b60a0308-d0e3-4021-897f-fc7c07e1ae3d.jpg?v=1765521114"},{"product_id":"bently-nevada-330100-90-00-3300-proximitor-sensor-signal-conditioning-module","title":"Bently Nevada 330100-90-00 3300 Proximitor Sensor Signal Conditioning Module","description":"\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330100-90-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a legacy 3300 series Proximitor Sensor used for vibration and displacement signal conditioning in proximity measurement systems. It is commonly deployed in legacy monitoring architectures across power generation, oil refinery, and heavy industrial rotating equipment where existing 3300 system infrastructure remains in operation.\u003c\/p\u003e\n\u003cp\u003eThis model is part of the original 3300 platform and has been superseded by the 3300 XL series, specifically the 330180-90-00 sensor. It still appears in installed base systems where upgrade cycles have not yet been completed.\u003c\/p\u003e\n\u003cp\u003eThe unit provides stable signal conversion from proximity probes into processed electrical outputs for vibration monitoring systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProduct Status and Replacement Path\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eItem\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOriginal Model\u003c\/td\u003e\n\u003ctd\u003e330100-90-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement\u003c\/td\u003e\n\u003ctd\u003e330180-90-00 3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus\u003c\/td\u003e\n\u003ctd\u003eLegacy \/ Discontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe 3300 XL replacement improves temperature stability, RFI immunity, and long-term signal accuracy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330100-90-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e9.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3300 proximity monitoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this model still in production?\u003c\/strong\u003e\u003cbr\u003eNo. It is a legacy product replaced by 3300 XL series sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended replacement?\u003c\/strong\u003e\u003cbr\u003eThe direct replacement is Bently Nevada 330180-90-00.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with existing 3300 probes?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for compatibility within 3300 legacy systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs performance better than 3300 XL?\u003c\/strong\u003e\u003cbr\u003eNo. The XL series provides improved accuracy and environmental stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Maintenance Notes\u003c\/h3\u003e\n\u003cp\u003eThis sensor is typically found in installed legacy monitoring systems that still operate reliably under industrial conditions.\u003c\/p\u003e\n\u003cp\u003eWhen maintaining existing systems, verify cable integrity and connector condition to avoid signal degradation.\u003c\/p\u003e\n\u003cp\u003eReplacement planning should consider migration to 3300 XL architecture for improved long-term reliability.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding to reduce noise in older installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProcurement Guidance\u003c\/h3\u003e\n\u003cp\u003eThis part is typically sourced for system maintenance rather than new installation projects.\u003c\/p\u003e\n\u003cp\u003eVerify compatibility with existing 3300 probe and extension cable configurations before procurement.\u003c\/p\u003e\n\u003cp\u003eFor long-term asset strategy, evaluate transition to 3300 XL platform to reduce lifecycle risk.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318744939,"sku":"330100-90-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330100-90-00-qtgu1fbtb3g_4982d076-6387-4e99-bff3-6c605b2a05e8.jpg?v=1765521115"},{"product_id":"330103-00-07-10-12-cn-bently-nevada-3300-xl-8-mm-proximity-probes","title":"330103-00-07-10-12-CN | Bently Nevada | 3300 XL 8 mm Proximity Probes","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330103-00-07-10-12-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 8 mm proximity probe designed for precise vibration and shaft displacement monitoring in critical rotating machinery. It is widely applied in turbines, compressors, and refinery pumps where stable signal integrity directly supports machine protection and predictive maintenance strategies.\u003c\/p\u003e\n\u003cp\u003eThis model integrates FluidLoc cable technology, improving resistance against oil contamination and moisture ingress in industrial environments. The compact 70 mm case length supports installations in restricted mounting zones, while maintaining consistent measurement linearity under continuous operation.\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector system ensures stable electrical contact in high-vibration conditions, reducing signal instability caused by mechanical loosening.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330103\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e70 mm overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis configuration defines probe geometry, sealing technology, cable protection level, and compliance classification.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-00-07-10-12-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.323 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFluidLoc sealed cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 \/ 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of FluidLoc cable?\u003c\/strong\u003e\u003cbr\u003eIt reduces fluid ingress risk and improves reliability in oil-rich environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe suitable for turbine applications?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly used in turbine vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes CN option affect performance?\u003c\/strong\u003e\u003cbr\u003eNo. It relates to certification and compliance only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it replace standard 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes, if mechanical and electrical configuration matches system requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain correct probe gap calibration to ensure accurate displacement measurement.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp cable bends near connector to preserve shielding integrity.\u003c\/p\u003e\n\u003cp\u003eRoute cables away from high EMI sources to maintain signal stability.\u003c\/p\u003e\n\u003cp\u003eEnsure secure mounting torque to prevent probe drift under vibration load.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Engineering Guidance\u003c\/h3\u003e\n\u003cp\u003eFluidLoc cable improves performance in oil mist and moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eThe 70 mm case design allows installation in compact machine housings.\u003c\/p\u003e\n\u003cp\u003eClickLoc connector enhances field reliability under continuous vibration exposure.\u003c\/p\u003e\n\u003cp\u003eSuitable for continuous monitoring in power generation and process industries.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318777707,"sku":"330103-00-07-10-12-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330103-00-07-10-12-cn-d5i5xv1x14b_aaac396f-a25b-4a3b-970a-454f02c85e64.jpg?v=1765521117"},{"product_id":"bently-nevada-330906-02-12-10-02-cn-3300-nsv-reverse-mount-proximity-probe","title":"Bently Nevada 330906-02-12-10-02-CN 3300 NSv Reverse Mount Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330906-02-12-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 NSv reverse mount proximity probe designed for vibration and shaft displacement monitoring in compact rotating machinery. It is typically used in auxiliary turbines, compressors, and pump systems where reverse installation geometry is required due to restricted mounting access.\u003c\/p\u003e\n\u003cp\u003eThe reverse mount design allows installation from the opposite direction of standard probe orientation, improving flexibility in dense mechanical assemblies. The NSv architecture maintains stable signal response in constrained environments while preserving compatibility with Bently Nevada monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe 1.0 meter cable configuration supports standard routing in industrial control layouts with moderate distance between probe and monitoring module.\u003c\/p\u003e\n\u003cp\u003eCN approval configuration supports deployment in regulated hazardous environments with regional certification requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330906\u003c\/td\u003e\n\u003ctd\u003e3300 NSv reverse mount probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eConnector\/cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eMechanical case and mounting configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines mounting direction, installation geometry, cable length, and compliance classification.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330906-02-12-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 NSv reverse mount proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eShaft vibration and position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eReverse mount configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is a reverse mount probe used for?\u003c\/strong\u003e\u003cbr\u003eIt is used when standard probe access is blocked or limited by machine structure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard NSv systems?\u003c\/strong\u003e\u003cbr\u003eYes. It follows NSv electrical and mechanical interface standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes reverse mounting affect signal accuracy?\u003c\/strong\u003e\u003cbr\u003eNo. Measurement performance remains unchanged if installation gap is correct.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs CN approval required for all installations?\u003c\/strong\u003e\u003cbr\u003eOnly for hazardous or regulated industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Field Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure probe alignment is verified during installation due to reverse mounting geometry.\u003c\/p\u003e\n\u003cp\u003eMaintain proper gap calibration after installation to ensure linear response accuracy.\u003c\/p\u003e\n\u003cp\u003eAvoid cable tension near connector to prevent long-term mechanical stress.\u003c\/p\u003e\n\u003cp\u003eUse proper grounding and shielding to reduce EMI influence in industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Application Guidance\u003c\/h3\u003e\n\u003cp\u003eReverse mount configuration improves installation flexibility in restricted machinery layouts.\u003c\/p\u003e\n\u003cp\u003eNSv design ensures stable vibration measurement in compact rotating equipment.\u003c\/p\u003e\n\u003cp\u003eClickLoc connector improves field reliability under continuous vibration exposure.\u003c\/p\u003e\n\u003cp\u003eSuitable for refinery, power generation, and process industry monitoring systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318810475,"sku":"330906-02-12-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330906-02-12-10-02-cn-wyzxxlhp0hb_98ae2c0b-5cbd-442a-910d-e7e83476e498.jpg?v=1765521119"},{"product_id":"bently-nevada-330902-00-95-05-02-00-3300-nsv-proximity-probe","title":"Bently Nevada 330902-00-95-05-02-00 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330902-00-95-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 NSv proximity probe designed for compact machinery vibration and shaft position measurement. It is typically deployed in small rotating equipment such as auxiliary pumps, compressors, and packaged turbine systems where installation space is restricted but monitoring precision remains critical.\u003c\/p\u003e\n\u003cp\u003eThe NSv architecture focuses on compact geometry and stable signal response under constrained mechanical layouts. The 0.5 meter system length supports short-distance routing, reducing cable exposure in dense machine environments. The ClickLoc connector ensures stable electrical contact under continuous vibration conditions.\u003c\/p\u003e\n\u003cp\u003eThis probe is used in condition monitoring systems where early detection of mechanical instability prevents unplanned downtime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330902\u003c\/td\u003e\n\u003ctd\u003e3300 NSv probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e9.5 in overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 m total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines probe geometry, installation depth, and system connectivity configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330902-00-95-05-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e9.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCompact rotating machinery monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe suitable for small machinery installations?\u003c\/strong\u003e\u003cbr\u003eYes. The NSv series is designed for compact equipment with limited mounting space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eIt is designed for NSv architecture. Compatibility depends on system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of 0.5 m cable length?\u003c\/strong\u003e\u003cbr\u003eIt reduces signal exposure and improves installation cleanliness in tight panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes ClickLoc improve reliability?\u003c\/strong\u003e\u003cbr\u003eYes. It reduces connector loosening under vibration conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct probe gap calibration during static alignment to stabilize baseline signal output.\u003c\/p\u003e\n\u003cp\u003eAvoid routing cables near high-current conductors to reduce EMI influence on signal quality.\u003c\/p\u003e\n\u003cp\u003eMaintain proper connector locking to prevent micro-disconnections in vibration-heavy environments.\u003c\/p\u003e\n\u003cp\u003eUse strain relief clamps near entry points to reduce mechanical fatigue.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Guidance\u003c\/h3\u003e\n\u003cp\u003eThis probe is optimized for compact rotating assets in industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003eIt provides stable displacement measurement in environments where traditional probe assemblies are too large.\u003c\/p\u003e\n\u003cp\u003eNSv design reduces installation footprint while maintaining vibration detection accuracy.\u003c\/p\u003e\n\u003cp\u003eProper grounding and shielding practices improve long-term signal stability in industrial environments.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318843243,"sku":"330902-00-95-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330902-00-95-05-02-00-zzdrhchkw3n_b284c29a-787b-4c07-ba8e-dbd7a8a6687c.jpg?v=1765521121"},{"product_id":"bently-nevada-330191-00-16-10-cn-3300-xl-8-mm-extended-temperature-range-etr-proximity-probes","title":"Bently Nevada 330191-00-16-10-CN | 3300 XL 8 mm Extended Temperature Range (ETR) Proximity Probes","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330191-00-16-10-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 8 mm Extended Temperature Range (ETR) proximity probe designed for vibration and shaft displacement monitoring in high-temperature rotating machinery environments. It is commonly applied in turbines, compressors, and refinery pumps where thermal stability and measurement accuracy directly affect machine protection logic.\u003c\/p\u003e\n\u003cp\u003eThe ETR design extends operating capability beyond standard probe temperature limits, ensuring stable signal behavior in hot housing zones and aggressive industrial conditions. The 1.0 meter system length supports standard installation routing in compact machine assemblies.\u003c\/p\u003e\n\u003cp\u003eCN approval marking supports deployment in regulated hazardous areas with compliance requirements such as ATEX, IECEx, and NEPSI.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Interpretation\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330191\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm ETR probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e1.6 in overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eHazardous area approvals (ATEX \/ IECEx \/ NEPSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis configuration defines probe geometry, installation depth, and compliance classification for industrial safety environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330191-00-16-10-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm ETR proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e1.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Category\u003c\/td\u003e\n\u003ctd\u003eExtended Temperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, NEPSI (CN variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe suitable for high-temperature turbine environments?\u003c\/strong\u003e\u003cbr\u003eYes. The ETR design supports extended thermal operating conditions in rotating machinery zones.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes CN version change electrical performance?\u003c\/strong\u003e\u003cbr\u003eNo. CN refers to approval and compliance marking only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it replace standard 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes, if mechanical and electrical specifications match system requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe compatible with 3300 XL extension cables?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates with standard 3300 XL system architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Field Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain stable probe gap calibration during cold shutdown conditions for repeatable signal accuracy.\u003c\/p\u003e\n\u003cp\u003eAvoid direct contact between probe cable and hot surfaces to prevent insulation degradation.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief near connector to reduce vibration-induced mechanical stress.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of cable shield to maintain signal integrity in EMI-heavy environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Application Guidance\u003c\/h3\u003e\n\u003cp\u003eThe ETR probe structure is optimized for environments with elevated ambient and housing temperatures.\u003c\/p\u003e\n\u003cp\u003eIt improves signal stability in turbine bearing housings and compressor casings where thermal drift affects standard probes.\u003c\/p\u003e\n\u003cp\u003eMechanical design ensures compatibility with existing 3300 XL installation footprints.\u003c\/p\u003e\n\u003cp\u003eProper installation alignment is critical to avoid phase shift in vibration readings.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318876011,"sku":"330191-00-16-10-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330191-00-16-10-cn-mgpvarytx5x_848cba76-b85f-4aa7-8dd1-63ab04fbe55f.jpg?v=1765521123"},{"product_id":"bently-nevada-330104-00-04-10-02-cn-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330104-00-04-10-02-CN 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330104-00-04-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 8 mm proximity probe designed for high-accuracy vibration and shaft position measurement in rotating machinery. It is widely applied in gas turbines, steam turbines, compressors, and critical process pumps where stable displacement monitoring directly affects machine protection and shutdown logic.\u003c\/p\u003e\n\u003cp\u003eThis probe uses a compact 8 mm sensing architecture with a 1.0 meter system length, making it suitable for standard industrial installations requiring balanced reach and rigidity. The ClickLoc connector system improves installation reliability in vibration-prone environments, while stainless steel construction ensures long-term mechanical stability in harsh operating conditions.\u003c\/p\u003e\n\u003cp\u003eThe CN configuration supports region-specific compliance requirements for hazardous industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProbe Configuration Logic\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330104\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe, 3\/8-24 UNF thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e40 mm overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines mechanical geometry, cable routing length, and compliance variant for regulated installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-04-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel (AISI 303 \/ 304)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing\u003c\/td\u003e\n\u003ctd\u003eViton O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates directly with Bently Nevada 3300 XL monitoring platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does CN option mean?\u003c\/strong\u003e\u003cbr\u003eIt indicates country-specific approvals for regulated industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this probe operate in high vibration conditions?\u003c\/strong\u003e\u003cbr\u003eYes. The stainless steel housing and ClickLoc connector improve mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the probe suitable for hazardous zones?\u003c\/strong\u003e\u003cbr\u003eYes, when installed under approved system configurations with correct certification chain.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Insights\u003c\/h3\u003e\n\u003cp\u003eEnsure probe gap calibration is performed during machine idle conditions for stable baseline readings.\u003c\/p\u003e\n\u003cp\u003eRoute cables away from high-current power lines to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius near connector to avoid mechanical stress on coaxial shielding.\u003c\/p\u003e\n\u003cp\u003eTighten mounting hardware to manufacturer torque specification to prevent drift under vibration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Notes for Industrial Use\u003c\/h3\u003e\n\u003cp\u003eThis probe is optimized for continuous condition monitoring systems in rotating machinery.\u003c\/p\u003e\n\u003cp\u003eStainless steel casing improves resistance against oil contamination and industrial moisture exposure.\u003c\/p\u003e\n\u003cp\u003eViton sealing ensures stable operation in moderate chemical environments commonly found in refinery and power plant applications.\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc interface reduces installation errors in field wiring operations.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318908779,"sku":"330104-00-04-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330104-00-04-10-02-cn-02wvqkgdr51_32ca5a0a-ba68-4a79-ae16-efacd1bdf16f.jpg?v=1765521124"},{"product_id":"bently-nevada-330910-00-03-10-02-00-3300-nsv-armored-proximity-probe","title":"Bently Nevada 330910-00-03-10-02-00 3300 NSv Armored Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330910-00-03-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 NSv proximity probe designed for high-precision shaft vibration and position monitoring in compact industrial rotating machinery. It is commonly used in pumps, compressors, small turbines, and auxiliary equipment where installation space is limited but measurement reliability remains critical.\u003c\/p\u003e\n\u003cp\u003eThis probe uses an M10 x 1 threaded mounting interface and armored cable construction to ensure mechanical protection and stable signal transmission in high-vibration environments. It is part of the NSv series, optimized for narrow-space applications while maintaining full compatibility with Bently Nevada monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe 1.0 meter total length configuration supports flexible routing in confined machinery layouts.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330910\u003c\/td\u003e\n\u003ctd\u003e3300 NSv probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e30 mm overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines probe geometry, installation interface, cable length, and connector configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330910-00-03-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.014 kg to 0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM10 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and shaft position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe NSv probe series is designed for compact machinery installations where standard probe geometries cannot be applied.\u003c\/p\u003e\n\u003cp\u003eArmored cable construction improves mechanical durability and reduces risk of damage in high-vibration zones.\u003c\/p\u003e\n\u003cp\u003eClickLoc connector design ensures stable electrical connection and reduces loosening under continuous mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this probe used?\u003c\/strong\u003e\u003cbr\u003eIt is used in small turbines, pumps, compressors, and compact rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy choose NSv probes?\u003c\/strong\u003e\u003cbr\u003eThey are optimized for tight installation spaces with full monitoring capability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes armor improve reliability?\u003c\/strong\u003e\u003cbr\u003eYes. It provides mechanical protection in vibration-intensive environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard Bently Nevada systems?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates with 3300 NSv monitoring architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct probe gap setup for accurate linear measurement response.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bends near connector and armored section to prevent mechanical fatigue.\u003c\/p\u003e\n\u003cp\u003eSecure probe mounting torque according to machine specifications.\u003c\/p\u003e\n\u003cp\u003eMaintain proper grounding of cable shield for signal stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse proper strain relief to prevent connector stress during vibration operation.\u003c\/p\u003e\n\u003cp\u003eInspect armored section periodically for mechanical wear in harsh environments.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high-power electrical cables to reduce EMI interference.\u003c\/p\u003e\n\u003cp\u003eVerify connector locking during installation to ensure stable signal transmission.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318974315,"sku":"330910-00-03-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330910-00-03-10-02-00-p0v5efj5lc2_08a8cbe4-e38d-45c1-b2ca-fd6c2d67b418.jpg?v=1765521125"},{"product_id":"bently-nevada-89477-20-interconnect-cable-20-ft-industrial-signal-link","title":"Bently Nevada 89477-20 Interconnect Cable 20 ft Industrial Signal Link","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 89477-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an interconnect cable designed for vibration monitoring and machinery protection systems where stable signal transmission between field devices and monitoring modules is required. It is commonly used in turbines, compressors, pumps, and industrial rotating equipment across power generation and process industries.\u003c\/p\u003e\n\u003cp\u003eThis cable provides a direct electrical link between system components, ensuring reliable data transfer in environments with vibration, electrical noise, and continuous industrial operation. It supports consistent signal integrity for condition monitoring systems where measurement accuracy directly affects machine protection decisions.\u003c\/p\u003e\n\u003cp\u003eThe 20 ft length configuration supports flexible installation in control cabinets and field-mounted monitoring setups.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e89477\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20 ft cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis simplified configuration defines cable family type and physical length for system integration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e89477-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e20 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSignal transmission for monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Role\u003c\/td\u003e\n\u003ctd\u003eInterconnect between monitoring and field devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eIndustrial machinery monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is designed for stable low-noise signal transmission in industrial environments where electromagnetic interference and mechanical vibration are present.\u003c\/p\u003e\n\u003cp\u003eIt ensures consistent connectivity between monitoring modules and field instrumentation, supporting accurate vibration and condition monitoring data acquisition.\u003c\/p\u003e\n\u003cp\u003eThe cable structure is optimized for durability under continuous industrial operation conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbine systems, compressors, pumps, and industrial monitoring panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is its main function?\u003c\/strong\u003e\u003cbr\u003eIt provides electrical interconnection between monitoring system components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for industrial vibration and electrical noise conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect performance?\u003c\/strong\u003e\u003cbr\u003eWithin specified design limits, 20 ft supports stable signal transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eRoute cable away from high-voltage power lines to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bends to maintain conductor integrity and signal stability.\u003c\/p\u003e\n\u003cp\u003eEnsure connectors are fully seated to prevent intermittent signal loss.\u003c\/p\u003e\n\u003cp\u003eUse proper cable management to reduce vibration-induced mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper grounding practices to ensure signal stability in noisy environments.\u003c\/p\u003e\n\u003cp\u003eInspect connector interfaces during scheduled maintenance cycles.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical tension on cable ends during installation.\u003c\/p\u003e\n\u003cp\u003eUse standardized routing paths inside control panels to improve reliability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319007083,"sku":"89477-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/89477-20-3chmqkzrnkk_aeabdb4b-577f-4515-af7c-d9847d23c650.jpg?v=1765521126"},{"product_id":"bently-nevada-21000-00-00-00-039-03-02-proximity-probe-housing-assemblies","title":"Bently Nevada 21000-00-00-00-039-03-02 Proximity Probe Housing Assemblies","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 21000-00-00-00-039-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a proximity probe housing assembly designed for industrial vibration monitoring systems where probe protection and mechanical installation flexibility are required. It is widely applied in turbines, compressors, pumps, and rotating machinery used in power plants, refineries, and heavy process industries.\u003c\/p\u003e\n\u003cp\u003eThis configuration supports installations where the probe and cable are not included, allowing system integrators to select external sensing components based on application requirements. It provides a stable mechanical interface for proximity measurement systems while maintaining environmental protection for the sensing point.\u003c\/p\u003e\n\u003cp\u003eThe housing ensures consistent probe positioning and mechanical isolation, improving measurement stability in vibration and shaft displacement monitoring applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMechanical Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e21000\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eProbe not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eProbe cable not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e039\u003c\/td\u003e\n\u003ctd\u003e3.9 in probe penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eNPT fittings with plugs, reducer, and cable sealing grips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines a probe-less housing configuration intended for flexible sensor system integration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e21000-00-00-00-039-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Requirement\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Requirement\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration\u003c\/td\u003e\n\u003ctd\u003e3.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAluminum body with 304 stainless steel sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFittings\u003c\/td\u003e\n\u003ctd\u003eNPT plug, reducer, cable seal grip set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring system housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis housing assembly is designed for system-level flexibility, allowing engineers to integrate preferred probe and cable configurations based on machine monitoring requirements.\u003c\/p\u003e\n\u003cp\u003eThe aluminum body provides lightweight structural support, while the stainless steel sleeve enhances corrosion resistance in industrial environments.\u003c\/p\u003e\n\u003cp\u003eCable sealing grips ensure environmental protection across multiple cable diameter ranges, improving installation adaptability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this housing used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, pumps, and industrial rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is probe not included?\u003c\/strong\u003e\u003cbr\u003eIt allows flexible selection of probe types based on application design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used outdoors?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for industrial environments with environmental sealing features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of modular configuration?\u003c\/strong\u003e\u003cbr\u003eIt supports customized sensor integration for different monitoring architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct NPT thread engagement to maintain housing sealing integrity.\u003c\/p\u003e\n\u003cp\u003eSelect appropriate cable seal grip size to match installed cable diameter.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical stress on housing during probe alignment procedures.\u003c\/p\u003e\n\u003cp\u003eVerify probe penetration alignment before final tightening of assembly.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse correct sealing components for environmental protection in outdoor installations.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of metallic housing components in electrically noisy environments.\u003c\/p\u003e\n\u003cp\u003eInspect cable seal grips periodically to maintain moisture resistance.\u003c\/p\u003e\n\u003cp\u003eAvoid over-tightening fittings to prevent housing deformation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319039851,"sku":"21000-00-00-00-039-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/21000-00-00-00-039-03-02-pdou1k3rmdk_83f53142-2932-44a3-bce4-213e9f7d8337.jpg?v=1765521127"},{"product_id":"bently-nevada-32000-16-05-00-080-03-02-32000-metric-proximity-probe-housing","title":"Bently Nevada 32000-16-05-00-080-03-02 | 32000 Metric Proximity Probe Housing","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 32000-16-05-00-080-03-02\u003c\/strong\u003e is a 32000 metric proximity probe housing designed for rugged industrial vibration monitoring applications. It is widely deployed in turbines, compressors, pumps, and heavy rotating machinery where environmental sealing and mechanical protection are required for stable proximity probe operation.\u003c\/p\u003e\n\u003cp\u003eThis housing integrates a 3300 XL 8 mm probe interface and provides sealed mechanical protection for measurement stability in harsh operating environments. It supports reliable shaft vibration and displacement monitoring in power generation, petrochemical, and heavy process industries.\u003c\/p\u003e\n\u003cp\u003eThe reinforced housing structure ensures long-term durability under high vibration, moisture exposure, and industrial contamination conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMechanical Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e32000\u003c\/td\u003e\n\u003ctd\u003eMetric proximity probe housing series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 m probe cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e80 mm probe penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eM20 fittings with plugs and armored cable grip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines probe interface geometry, penetration depth, and installation hardware configuration for industrial assembly.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e32000-16-05-00-080-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMetric proximity probe housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP66, Type 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 to 105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eGlass reinforced PPS thermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetal Components\u003c\/td\u003e\n\u003ctd\u003eAISI 304 and AISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eO-ring Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and shaft position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe 32000 housing system is engineered for mechanical isolation and environmental sealing of proximity probes in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eGlass reinforced PPS material provides high resistance to chemical exposure and mechanical impact, while maintaining dimensional stability under temperature variation.\u003c\/p\u003e\n\u003cp\u003eStainless steel components ensure corrosion resistance in offshore and chemical processing applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this housing used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, pumps, and heavy industrial rotating equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for outdoor installation?\u003c\/strong\u003e\u003cbr\u003eYes. IP66 and Type 4X ratings support harsh outdoor environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes this housing impact resistant?\u003c\/strong\u003e\u003cbr\u003eCertified structural design allows repeated mechanical impact resistance under extreme temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used in hazardous areas?\u003c\/strong\u003e\u003cbr\u003eYes. It meets electrostatic dissipation requirements for hazardous environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct NPT thread sealing to maintain environmental protection integrity.\u003c\/p\u003e\n\u003cp\u003eVerify probe penetration depth alignment before tightening final assembly.\u003c\/p\u003e\n\u003cp\u003eUse proper torque control during installation to avoid housing stress deformation.\u003c\/p\u003e\n\u003cp\u003eMaintain cable sealing integrity using correct M20 fitting configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eAvoid direct mechanical load on housing body during installation.\u003c\/p\u003e\n\u003cp\u003eEnsure grounding continuity for metallic components in hazardous environments.\u003c\/p\u003e\n\u003cp\u003eInspect sealing components periodically in corrosive or offshore environments.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable strain relief to avoid connector fatigue under vibration.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319072619,"sku":"32000-16-05-00-080-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/32000-16-05-00-080-03-02-dswb4ne3znn_5643a083-40e0-4665-9c9a-ec00e19744b4.jpg?v=1765521129"},{"product_id":"bently-nevada-330190-045-00-00-3300-xl-extended-temperature-range-etr-extension-cable","title":"Bently Nevada 330190-045-00-00  | 3300 XL Extended Temperature Range (ETR) Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330190-045-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL Extended Temperature Range (ETR) extension cable designed for vibration monitoring systems operating in thermally demanding industrial environments. It is commonly used in turbines, compressors, and process machinery where stable signal transmission must be maintained under elevated temperature conditions.\u003c\/p\u003e\n\u003cp\u003eThis cable supports reliable data transfer between proximity probes and monitoring modules while minimizing signal drift caused by thermal stress. It is applied in power generation, oil and gas, and heavy industrial systems where temperature stability directly affects machine protection accuracy.\u003c\/p\u003e\n\u003cp\u003eThe 4.5 meter configuration provides flexible routing in compact and mid-range machinery installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330190\u003c\/td\u003e\n\u003ctd\u003e3300 XL ETR extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e045\u003c\/td\u003e\n\u003ctd\u003e4.5 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo additional cable option required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines cable length and configuration level within the ETR extension cable family.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-045-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended temperature range extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eTriaxial ETR design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eHigh temperature industrial systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ETR cable design maintains stable electrical characteristics under elevated temperature conditions where standard extension cables may experience signal drift or insulation degradation.\u003c\/p\u003e\n\u003cp\u003eTriaxial construction ensures low-noise signal transmission and stable impedance performance, which is critical for accurate vibration monitoring in rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThe cable is optimized for integration in high-temperature zones such as turbine casings and compressor housings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and high-temperature industrial machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of ETR design?\u003c\/strong\u003e\u003cbr\u003eIt ensures stable signal performance under elevated thermal conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates into the 3300 XL monitoring architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect performance?\u003c\/strong\u003e\u003cbr\u003eWithin specification, 4.5 m length maintains stable signal transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid routing near high-temperature steam lines exceeding rated limits.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-power electrical cables to reduce EMI interference.\u003c\/p\u003e\n\u003cp\u003eEnsure correct connector engagement to maintain signal stability.\u003c\/p\u003e\n\u003cp\u003eUse appropriate cable supports to prevent mechanical stress in high-vibration areas.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius to protect triaxial shielding integrity.\u003c\/p\u003e\n\u003cp\u003eInspect insulation condition during scheduled maintenance in high-heat environments.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shielding for optimal noise suppression.\u003c\/p\u003e\n\u003cp\u003eAvoid direct contact with hot surfaces or radiant heat sources.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319105387,"sku":"330190-045-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330190-045-00-00-extension-cable-vv44ifx1gve_81f44a4c-8bd7-4af8-8fdb-50fa958ad864.jpg?v=1765440498"},{"product_id":"bently-nevada-330730-080-13-cn-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-080-13-CN 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330730-080-13-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 11 mm extension cable designed for vibration monitoring systems used in heavy industrial rotating machinery. It is widely applied in turbines, compressors, and large motor-driven equipment in power plants, oil refineries, and mining operations.\u003c\/p\u003e\n\u003cp\u003eThis cable ensures stable signal transmission between 11 mm proximity probes and monitoring modules under high vibration and electrically noisy conditions. The armored FluidLoc construction improves mechanical protection and maintains signal integrity in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe 8.0 meter length supports flexible installation layouts in distributed monitoring architectures while maintaining consistent electrical performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330730\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable with connector protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach configuration element defines mechanical protection level, cable length, and compliance classification within the 3300 XL 11 mm system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330730-080-13-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e11 mm extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eConnector protectors included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL 11 mm series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 11 mm cable series is engineered for enhanced signal stability in large rotating machinery applications where longer cable runs and higher electromagnetic interference levels are present.\u003c\/p\u003e\n\u003cp\u003eArmored FluidLoc construction provides mechanical durability while maintaining low-noise electrical performance, reducing the risk of signal distortion caused by vibration or cable movement.\u003c\/p\u003e\n\u003cp\u003eConnector protectors improve long-term reliability by preventing contamination and mechanical wear at interface points.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and large industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored FluidLoc design?\u003c\/strong\u003e\u003cbr\u003eIt increases mechanical durability and improves signal reliability in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all 11 mm probes?\u003c\/strong\u003e\u003cbr\u003eIt is designed for Bently Nevada 3300 XL 11 mm proximity systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy are connector protectors important?\u003c\/strong\u003e\u003cbr\u003eThey reduce contamination and mechanical damage at connection interfaces.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid tight bending near connector ends to preserve signal stability.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-voltage cables and VFD systems to reduce interference.\u003c\/p\u003e\n\u003cp\u003eEnsure connector locking is fully engaged during installation.\u003c\/p\u003e\n\u003cp\u003eSecure cable routing to avoid vibration-induced mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse proper strain relief at both ends to avoid load transfer to connectors.\u003c\/p\u003e\n\u003cp\u003eInspect armor integrity during scheduled maintenance cycles.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius for armored cable sections.\u003c\/p\u003e\n\u003cp\u003eEnsure grounding continuity for shielding effectiveness in noisy environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319138155,"sku":"330730-080-13-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330730-080-13-cn-kzhtnrvtql2_2c22313d-9614-48ef-a61d-d34f6f313b5d.jpg?v=1765521131"},{"product_id":"bently-nevada-330101-00-10-10-02-00-3300-xl-8-mm-proximity-transducer-system","title":"Bently Nevada 330101-00-10-10-02-00 3300 XL 8 mm Proximity Transducer System","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330101-00-10-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 8 mm proximity transducer system designed for precise shaft vibration and position measurement in industrial rotating machinery. It is widely deployed in turbines, compressors, pumps, and generators across power generation, oil and gas, and heavy process industries.\u003c\/p\u003e\n\u003cp\u003eThis system provides stable, high-resolution displacement measurement for machine protection and condition monitoring applications. It supports early detection of mechanical faults such as imbalance, misalignment, and bearing wear, helping reduce unplanned shutdowns and maintenance risk.\u003c\/p\u003e\n\u003cp\u003eThe 1.0 meter system configuration enables compact integration in standard monitoring assemblies while maintaining signal integrity across the full measurement chain.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330101\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe, 3\/8-24 UNF thread, no armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 in overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines probe geometry, mechanical interface, cable length, connector type, and certification scope.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-10-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e323 g per meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity transducer system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Size\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eShaft vibration and position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL transducer system is designed to deliver stable, linear response across industrial vibration ranges. It ensures accurate gap measurement between probe tip and target surface in rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector system improves installation reliability by reducing connector loosening under vibration conditions.\u003c\/p\u003e\n\u003cp\u003eThe system architecture supports consistent calibration behavior across the 3300 XL platform, enabling interchangeability within compatible monitoring systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this system used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, pumps, and industrial rotating equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main function?\u003c\/strong\u003e\u003cbr\u003eIt measures shaft vibration and radial position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with existing 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates into standard 3300 XL monitoring architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is system length important?\u003c\/strong\u003e\u003cbr\u003eIt defines installation flexibility and signal routing constraints in machinery layouts.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct probe gap setting during installation to maintain linear measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive bending near the connector to prevent signal degradation under vibration.\u003c\/p\u003e\n\u003cp\u003eVerify mechanical mounting torque to prevent probe displacement during operation.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high-voltage cables to reduce electromagnetic interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse rigid mounting structures to maintain stable probe-to-target alignment.\u003c\/p\u003e\n\u003cp\u003eInspect connector locking mechanism during scheduled maintenance intervals.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of cable shielding for noise reduction in VFD environments.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical stress on probe housing during installation and alignment procedures.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319170923,"sku":"330101-00-10-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-10-10-02-00-kzy2kisp4et_3539c89e-d628-4f99-8c51-34fb0fdfc3fa.jpg?v=1765521132"},{"product_id":"bently-nevada-330190-080-00-cn-3300-xl-extended-temperature-range-etr-extension-cable","title":"Bently Nevada 330190-080-00-CN | 3300 XL Extended Temperature Range (ETR) Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330190-080-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL Extended Temperature Range (ETR) extension cable designed for vibration monitoring systems operating in elevated and thermally unstable industrial environments. It is applied in turbines, compressors, petrochemical units, and power generation systems where signal stability must be maintained under continuous thermal stress.\u003c\/p\u003e\n\u003cp\u003eThis cable supports reliable signal transmission between proximity probes and monitoring modules while maintaining electrical integrity across extended temperature conditions. It reduces measurement drift and protects machine protection systems from signal degradation in harsh operating zones.\u003c\/p\u003e\n\u003cp\u003eThe 8.0 meter configuration provides flexible installation for distributed monitoring layouts in large industrial machinery assemblies.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330190\u003c\/td\u003e\n\u003ctd\u003e3300 XL extended temperature range cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines mechanical configuration, electrical design standard, and compliance classification within the ETR extension cable family.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-080-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended temperature range extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, FEP insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Capability\u003c\/td\u003e\n\u003ctd\u003eExtended temperature design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ETR cable series is designed for environments where standard extension cables cannot maintain stable electrical characteristics under elevated temperatures.\u003c\/p\u003e\n\u003cp\u003eFluoroethylene propylene (FEP) insulation improves thermal resistance and chemical stability, making the cable suitable for oil, gas, and high-temperature industrial environments.\u003c\/p\u003e\n\u003cp\u003eTriaxial construction ensures low-noise signal transmission and stable impedance characteristics across long cable runs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and high-temperature industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes ETR cables different?\u003c\/strong\u003e\u003cbr\u003eThey maintain electrical stability under extended temperature conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is fully compatible with 3300 XL proximity measurement architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is triaxial construction important?\u003c\/strong\u003e\u003cbr\u003eIt reduces noise and improves signal stability in electrically harsh environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid routing near high-temperature steam lines or heat sources exceeding rated limits.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shielding to maintain signal integrity in noisy electrical environments.\u003c\/p\u003e\n\u003cp\u003eMaintain proper bend radius to avoid degradation of triaxial shielding structure.\u003c\/p\u003e\n\u003cp\u003eVerify connector seating before commissioning to ensure stable measurement output.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse thermal spacing in cable routing to avoid continuous exposure to radiant heat sources.\u003c\/p\u003e\n\u003cp\u003eEnsure proper strain relief at cabinet entry points to prevent mechanical stress transfer.\u003c\/p\u003e\n\u003cp\u003eInspect insulation condition periodically in high-temperature applications.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high-power electrical cables to minimize EMI interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319203691,"sku":"330190-080-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330190-080-00-cn-smlnidfadci_9cfde8bb-9bc1-4ff1-8ff6-c9d3ef82773c.jpg?v=1765521134"},{"product_id":"bently-nevada-330130-040-11-00-3300-xl-extension-cable","title":"Bently Nevada 330130-040-11-00 3300 XL Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330130-040-11-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL extension cable designed for reliable signal transmission in proximity measurement systems used for vibration and shaft position monitoring. It is commonly deployed in turbines, compressors, generators, and industrial rotating machinery where stable signal integrity directly impacts machine protection performance.\u003c\/p\u003e\n\u003cp\u003eThis cable supports armored FluidLoc construction, which improves resistance to mechanical damage, oil exposure, and harsh industrial handling conditions. It ensures stable electrical continuity between proximity probes and monitoring modules in high-vibration environments.\u003c\/p\u003e\n\u003cp\u003eThe 4.0 meter length configuration provides flexible installation in control cabinets and field-mounted monitoring systems while maintaining signal stability across extended routing paths.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConstruction \u0026amp; Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e040\u003c\/td\u003e\n\u003ctd\u003e4.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe configuration defines cable length, mechanical protection level, and compliance scope within the 3300 XL system architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-040-11-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eMechanical abrasion resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is engineered to maintain low-noise signal transmission between proximity probes and monitoring systems in high-vibration industrial environments.\u003c\/p\u003e\n\u003cp\u003eArmored FluidLoc construction provides enhanced mechanical durability, reducing risk of cable damage during installation and long-term operation in harsh machinery areas.\u003c\/p\u003e\n\u003cp\u003eThe shielding design ensures signal stability in electrically noisy environments such as turbine halls and compressor stations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in vibration monitoring systems for turbines, compressors, and industrial rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored FluidLoc design?\u003c\/strong\u003e\u003cbr\u003eIt improves mechanical protection and reduces signal disruption in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for Bently Nevada 3300 XL proximity measurement systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect signal quality?\u003c\/strong\u003e\u003cbr\u003eWithin system specifications, 4.0 m length maintains stable signal performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid sharp bending during installation to prevent damage to internal conductors and shielding.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-voltage and VFD cables to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eEnsure connectors are fully engaged and locked to prevent intermittent signal loss.\u003c\/p\u003e\n\u003cp\u003eSecure cable routing to avoid mechanical stress from vibration or movement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius for armored construction to prevent long-term fatigue.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief at connection points to protect connector integrity.\u003c\/p\u003e\n\u003cp\u003eInspect cable shielding continuity during commissioning for optimal signal performance.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of system shielding to minimize electrical noise interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319236459,"sku":"330130-040-11-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-040-11-00-extension-cable-qn2ay5mvagf_f310ea0b-ffcd-478a-8ed5-6392231e7e8a.jpg?v=1765440915"},{"product_id":"bently-nevada-84661-34-10-meter-velomitor-interconnect-cable","title":"Bently Nevada 84661-34 | 10 meter Velomitor Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 84661-34\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 10 meter Velomitor interconnect cable designed for reliable signal transmission between velocity transducers and vibration monitoring systems. It is used in industrial machinery protection systems across power generation, oil and gas, and process industries where stable vibration signal integrity is critical.\u003c\/p\u003e\n\u003cp\u003eThis cable assembly provides a rugged armored construction to protect signal transmission in high-vibration and harsh environmental conditions. It ensures consistent data transfer from HTVS velocity sensors to monitoring equipment without degradation caused by electrical noise or mechanical stress.\u003c\/p\u003e\n\u003cp\u003eThe stainless steel armor layer enhances mechanical durability, making it suitable for installations exposed to abrasion, moisture, and industrial handling stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConstruction \u0026amp; Design Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Core\u003c\/td\u003e\n\u003ctd\u003eShielded 22 AWG (0.382 mm2) conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eStainless steel protective layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor End\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector (HTVS side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor End\u003c\/td\u003e\n\u003ctd\u003eRing lug termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe structure is engineered to maintain signal integrity while providing mechanical protection in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e84661-34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eArmored interconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Connection\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Connection\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVelocity transducer signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is designed to maintain stable low-noise signal transmission between velocity sensors and monitoring systems in electrically and mechanically harsh environments.\u003c\/p\u003e\n\u003cp\u003eStainless steel armor protects the internal conductors from abrasion and mechanical damage during installation and long-term operation.\u003c\/p\u003e\n\u003cp\u003eShielded conductor design reduces electromagnetic interference, ensuring signal accuracy in environments with variable frequency drives and high-power electrical systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in power plants, refineries, and industrial machinery vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is armored cable important?\u003c\/strong\u003e\u003cbr\u003eIt protects signal integrity against mechanical damage and harsh industrial handling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with all Velomitor sensors?\u003c\/strong\u003e\u003cbr\u003eIt is designed for compatible Bently Nevada Velomitor and HTVS systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it reduce electrical noise?\u003c\/strong\u003e\u003cbr\u003eYes. Shielded construction helps minimize EMI interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid excessive bending during installation to prevent internal conductor stress.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shield layer to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eRoute cable away from high-voltage and VFD power lines for optimal signal integrity.\u003c\/p\u003e\n\u003cp\u003eSecure stainless steel armor properly at mounting points to prevent vibration-induced fatigue.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius to avoid long-term mechanical fatigue in armored structure.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing periodically in moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief at both ends to prevent mechanical load transfer to connectors.\u003c\/p\u003e\n\u003cp\u003eEnsure ring lug termination is firmly secured to monitoring system terminals for stable signal transmission.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319269227,"sku":"84661-34","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/84661-34-xineykv00ar_bd189d67-6de3-412b-8dbc-91f4c1b8515a.jpg?v=1765521137"},{"product_id":"bently-nevada-1900-65a-00-01-01-cn-01-1900-65a-general-purpose-equipment-monitor","title":"Bently Nevada  1900\/65A-00-01-01-CN-01 | 1900\/65A General Purpose Equipment Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 1900\/65A-00-01-01-CN-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a general purpose equipment monitor designed for continuous condition monitoring of industrial rotating machinery. It is widely used in power plants, oil and gas facilities, and process industries to supervise vibration, temperature, and auxiliary equipment parameters through a centralized monitoring architecture.\u003c\/p\u003e\n\u003cp\u003eThis monitor supports real-time machine protection logic and integrates with PLC and DCS systems via Modbus communication. It is typically deployed on pumps, compressors, fans, and auxiliary machinery where early fault detection reduces unplanned downtime and protects critical assets.\u003c\/p\u003e\n\u003cp\u003eThe DIN rail mounting design enables compact installation inside control cabinets, supporting high-density industrial automation layouts.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1900\/65A\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose equipment monitor series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e18 to 36 Vdc power supply option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eAttached display module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approval configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eModbus communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines power input range, display configuration, mounting method, certification scope, and communication protocol within the 1900\/65A platform.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1900\/65A-00-01-01-CN-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose equipment monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 36 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eAttached display module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery condition monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003ePLC, DCS, industrial monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe 1900\/65A platform is designed for centralized monitoring of multiple machine parameters in a single control unit. It reduces system complexity by consolidating data acquisition and alarm logic into a compact DIN rail device.\u003c\/p\u003e\n\u003cp\u003eModbus communication enables straightforward integration into existing industrial automation networks without requiring proprietary interfaces.\u003c\/p\u003e\n\u003cp\u003eThe attached display provides local visualization of machine status, reducing dependency on external HMI systems during commissioning and troubleshooting.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this monitor used?\u003c\/strong\u003e\u003cbr\u003eIt is used in power plants, refineries, and industrial process facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it integrate with PLC systems?\u003c\/strong\u003e\u003cbr\u003eYes. It supports Modbus communication for PLC and DCS integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of DIN rail mounting?\u003c\/strong\u003e\u003cbr\u003eIt allows compact and standardized installation inside control cabinets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for multi-machine monitoring?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for general purpose equipment monitoring across multiple assets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure stable 24 Vdc power supply within specified range to avoid system instability.\u003c\/p\u003e\n\u003cp\u003eInstall on DIN rail with proper mechanical locking to prevent vibration-induced loosening.\u003c\/p\u003e\n\u003cp\u003eRoute communication cables away from high-power circuits to reduce signal interference.\u003c\/p\u003e\n\u003cp\u003eVerify Modbus addressing configuration before system integration to ensure correct data mapping.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper cabinet ventilation to avoid thermal accumulation during continuous operation.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication cabling in electrically noisy environments to improve signal integrity.\u003c\/p\u003e\n\u003cp\u003ePerform periodic firmware and configuration checks to maintain monitoring accuracy.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of control cabinet to reduce electromagnetic interference effects.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319301995,"sku":"1900\/65A-00-01-01-CN-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/190065a-00-01-01-cn-01-nthcmjs01rc_c0105460-47d4-4f07-a321-65c5e2791e08.jpg?v=1765521138"},{"product_id":"bently-nevada-330902-00-15-10-02-cn-3300-nsv-proximity-probe","title":"Bently Nevada 330902-00-15-10-02-CN 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330902-00-15-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 NSv armored proximity probe designed for vibration and shaft position measurement in compact rotating machinery. It is typically applied in small turbines, compressors, and pump systems where installation space is limited but measurement stability remains essential for protection systems.\u003c\/p\u003e\n\u003cp\u003eThe NSv architecture focuses on compact geometry and stable signal output under high vibration conditions. The armored cable construction improves mechanical protection in harsh industrial environments where cable abrasion or impact risk exists.\u003c\/p\u003e\n\u003cp\u003eThis model supports 1.0 meter system length and integrates ClickLoc connector technology for stable electrical contact under continuous operation.\u003c\/p\u003e\n\u003cp\u003eThe CN configuration supports ATEX, IECEx, and NEPSI hazardous area compliance requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330902\u003c\/td\u003e\n\u003ctd\u003e3300 NSv probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e1.5 in overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eHazardous area approvals (ATEX \/ IECEx \/ NEPSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines probe geometry, installation interface, cable system, and compliance classification.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330902-00-15-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e14 g to 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 NSv armored proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e1.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eArmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCompact rotating machinery monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe suitable for high vibration equipment?\u003c\/strong\u003e\u003cbr\u003eYes. The NSv design and armored cable improve durability in vibration-heavy environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does CN certification include?\u003c\/strong\u003e\u003cbr\u003eIt includes ATEX, IECEx, and NEPSI hazardous area approvals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used in standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eNo. It belongs to NSv architecture and requires compatible system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored cable?\u003c\/strong\u003e\u003cbr\u003eIt provides mechanical protection against abrasion and impact damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct probe gap calibration during static installation to maintain measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp cable bends near connector to prevent armor fatigue and internal conductor stress.\u003c\/p\u003e\n\u003cp\u003eRoute cable away from high-current conductors to reduce EMI influence.\u003c\/p\u003e\n\u003cp\u003eSecure mounting to prevent micro-movement under long-term vibration exposure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Guidance\u003c\/h3\u003e\n\u003cp\u003eNSv armored probes are designed for compact rotating machinery requiring robust mechanical protection.\u003c\/p\u003e\n\u003cp\u003eArmored cable improves reliability in oil mist, dust, and mechanical contact risk environments.\u003c\/p\u003e\n\u003cp\u003eClickLoc connector ensures stable signal transmission under continuous industrial vibration.\u003c\/p\u003e\n\u003cp\u003eSuitable for compressor packages, pumps, and small turbine monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668320907627,"sku":"330902-00-15-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330902-00-15-10-02-cn-qw0htv3mvvg_6b0e0cbe-180f-4a28-bcee-e279b90ad4a0.jpg?v=1765521143"},{"product_id":"bently-nevada-330704-00-05-10-02-cn-3300-xl-11-mm-armored-proximity-probe","title":"Bently Nevada 330704-00-05-10-02-CN 3300 XL 11 mm Armored Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330704-00-05-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 11 mm armored proximity probe designed for shaft vibration and position monitoring in turbines, compressors, generators, and heavy industrial rotating machinery. It operates within the Bently Nevada 3300 XL eddy-current system and delivers stable displacement signals in harsh mechanical and electrical environments.\u003c\/p\u003e\n\u003cp\u003eThis probe is built for applications requiring enhanced mechanical protection through armored cable construction. It is commonly deployed in refineries, power plants, and offshore installations where vibration, oil exposure, and mechanical abrasion are continuous operating conditions.\u003c\/p\u003e\n\u003cp\u003eThe M14 x 1.5 threaded interface provides secure installation and stable alignment under high vibration loads, ensuring long-term measurement consistency in critical machinery protection systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330704\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm armored probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e5 mm case length option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m system cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approval configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines probe geometry, cable length, connector type, and regional compliance classification within the 3300 XL probe system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330704-00-05-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e11 mm armored proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM14 x 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eArmored construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing Material\u003c\/td\u003e\n\u003ctd\u003eViton O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and shaft position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe armored cable construction provides additional mechanical protection against abrasion, impact, and installation damage in harsh industrial environments. This improves long-term reliability in high-vibration machinery zones.\u003c\/p\u003e\n\u003cp\u003eThe PPS probe tip material ensures stable dielectric performance under elevated temperature conditions, maintaining linear response in eddy-current measurement systems.\u003c\/p\u003e\n\u003cp\u003eThe stainless steel probe body enhances corrosion resistance and mechanical rigidity, supporting long-term deployment in refinery and offshore applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this probe used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and heavy rotating machinery in industrial plants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored cable?\u003c\/strong\u003e\u003cbr\u003eIt provides mechanical protection against abrasion and external damage in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is fully compatible with Bently Nevada 3300 XL monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it operate in high-temperature zones?\u003c\/strong\u003e\u003cbr\u003eYes. It supports operation up to 177 deg C.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct M14 thread torque during installation to prevent misalignment under vibration stress.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bending of armored cable to maintain internal conductor integrity.\u003c\/p\u003e\n\u003cp\u003eRoute probe cable away from high-voltage and VFD output wiring to reduce EMI influence.\u003c\/p\u003e\n\u003cp\u003eVerify probe gap calibration before system commissioning to ensure correct signal linearity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper cable routing radius to avoid mechanical fatigue in armored sheath over time.\u003c\/p\u003e\n\u003cp\u003eInspect connector locking mechanism during installation to ensure stable electrical contact.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical shock during installation to protect probe tip alignment accuracy.\u003c\/p\u003e\n\u003cp\u003ePerform periodic inspection in high-vibration environments to ensure long-term stability of mounting and signal output.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321071467,"sku":"330704-00-05-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330704-00-05-10-02-cn-qj3ibpvxrxi_48670bdc-4c6f-4ee7-b1a5-b70f6137f0ca.jpg?v=1765521144"},{"product_id":"bently-nevada-31000-28-05-15-042-06-02-31000-proximity-probe-housings","title":"Bently Nevada 31000-28-05-15-042-06-02 31000 Proximity Probe Housings","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 31000-28-05-15-042-06-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 31000 series proximity probe housing assembly designed for 3300 XL 8 mm probe integration in hazardous and heavy-duty industrial environments. It is widely used in turbines, compressors, pumps, and refinery rotating equipment where stable probe positioning and environmental sealing directly impact machine protection reliability.\u003c\/p\u003e\n\u003cp\u003eThis housing supports high-integrity vibration and shaft displacement measurement under extreme mechanical stress, chemical exposure, and wide temperature variations. It is engineered for long-term deployment in critical asset monitoring systems where downtime reduction is a primary operational target.\u003c\/p\u003e\n\u003cp\u003eThe reinforced PPS thermoplastic body with conductive fibers provides electrostatic dissipation, while stainless steel structural elements ensure mechanical stability in high-vibration installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e31000\u003c\/td\u003e\n\u003ctd\u003e31000 series proximity probe housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe compatibility with approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 m probe cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e1.5 in standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e042\u003c\/td\u003e\n\u003ctd\u003e4.2 in probe penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eMulti-fitting configuration with reducer and plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach segment defines probe compatibility, mechanical depth, mounting geometry, and installation flexibility for hazardous area applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e31000-28-05-15-042-06-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Probe\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandoff Adapter\u003c\/td\u003e\n\u003ctd\u003e1.5 in (38 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration\u003c\/td\u003e\n\u003ctd\u003e4.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eGlass-reinforced PPS with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetal Components\u003c\/td\u003e\n\u003ctd\u003eAISI 303 \/ 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to 105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP66, Type 4X certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpact Resistance\u003c\/td\u003e\n\u003ctd\u003eUp to 7 Joule certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHazardous area machinery monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis housing is designed for hazardous industrial zones where electrostatic control and mechanical durability are critical. The conductive PPS material dissipates static charge, reducing ignition risk in explosive atmospheres.\u003c\/p\u003e\n\u003cp\u003eStainless steel reinforcement ensures structural integrity under continuous vibration and thermal cycling conditions common in refinery and offshore installations.\u003c\/p\u003e\n\u003cp\u003eThe impact-tested design ensures survivability in harsh industrial environments where accidental mechanical shocks may occur during maintenance or operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this housing used?\u003c\/strong\u003e\u003cbr\u003eIt is used in refineries, petrochemical plants, offshore platforms, and heavy industrial rotating equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is PPS material important?\u003c\/strong\u003e\u003cbr\u003eIt provides electrostatic dissipation and chemical resistance in hazardous environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for explosion risk areas?\u003c\/strong\u003e\u003cbr\u003eYes. It is certified for hazardous area operation with appropriate protection ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of stainless steel structure?\u003c\/strong\u003e\u003cbr\u003eIt improves mechanical strength and corrosion resistance in harsh environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct NPT torque tightening to maintain sealing integrity in hazardous environments.\u003c\/p\u003e\n\u003cp\u003eVerify proper alignment of probe penetration depth before commissioning to maintain measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eUse approved sealing methods for threaded connections to prevent fluid or gas ingress.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical stress on housing during installation to preserve internal alignment stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper grounding strategy to ensure electrostatic discharge performance of conductive housing material.\u003c\/p\u003e\n\u003cp\u003eInspect sealing integrity periodically in corrosive environments such as offshore or chemical plants.\u003c\/p\u003e\n\u003cp\u003eAvoid over-tightening fittings to prevent stress fractures in thermoplastic housing structure.\u003c\/p\u003e\n\u003cp\u003eEnsure cable routing avoids high-voltage conductors to reduce EMI influence on measurement signals.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321104235,"sku":"31000-28-05-15-042-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-31000-28-05-15-042-06-02-proximity-probe-housingassemblies-3zmymb5ddzt_41ebb7ce-f875-430f-9688-e40b999cde6e.jpg?v=1765447145"},{"product_id":"bently-nevada-21000-28-10-0-41-04-02-proximity-probe-housing-assembly","title":"Bently Nevada 21000-28-10-0-41-04-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 21000-28-10-0-41-04-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a proximity probe housing assembly designed for secure installation of 3300 XL 8 mm proximity probes in industrial rotating machinery monitoring applications. It is widely applied in turbines, compressors, pumps, and heavy-duty process equipment where stable probe positioning is required for accurate vibration and shaft displacement measurement.\u003c\/p\u003e\n\u003cp\u003eThis housing system provides a rigid mechanical interface between the probe and machine casing, ensuring consistent probe penetration and alignment under continuous vibration and thermal stress. It supports reliable eddy-current signal generation in condition monitoring systems used for asset protection and predictive maintenance.\u003c\/p\u003e\n\u003cp\u003eThe 3\/4-14 NPT mounting interface enables standardized integration into industrial machine housings, supporting both OEM installation and retrofit applications in power generation and process industries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e21000\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe option with approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m probe cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003ctd\u003eProbe penetration configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT plug included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines probe compatibility, installation geometry, penetration depth, and mechanical interface configuration within the housing system architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e21000-28-10-0-41-04-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Probe\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration\u003c\/td\u003e\n\u003ctd\u003e41 configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandoff Adapter\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFittings\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and shaft displacement monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis housing assembly ensures fixed mechanical positioning of proximity probes to maintain measurement accuracy in high-vibration industrial environments. It eliminates installation variability caused by mechanical drift, thermal expansion, and housing deformation.\u003c\/p\u003e\n\u003cp\u003eProbe penetration configuration defines the physical depth relationship between probe tip and target surface, which directly affects signal linearity in eddy-current measurement systems.\u003c\/p\u003e\n\u003cp\u003eThe standardized NPT interface simplifies integration into machine housings without requiring custom machining or adapter structures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this housing used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, pumps, and industrial rotating machinery requiring stable probe installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is probe penetration important?\u003c\/strong\u003e\u003cbr\u003eIt ensures correct gap positioning for accurate vibration signal generation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with non-3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed specifically for Bently Nevada 3300 XL 8 mm probe systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of NPT mounting?\u003c\/strong\u003e\u003cbr\u003eIt allows standardized and reliable mechanical integration into industrial equipment housings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct torque application during NPT thread installation to prevent misalignment or mechanical stress on housing structure.\u003c\/p\u003e\n\u003cp\u003eVerify probe penetration depth before system commissioning to ensure correct calibration of gap voltage output.\u003c\/p\u003e\n\u003cp\u003eMaintain clean mounting surfaces to avoid debris interference affecting probe alignment and measurement stability.\u003c\/p\u003e\n\u003cp\u003eRoute probe cables away from high-voltage conductors and VFD output lines to minimize electromagnetic interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eAvoid mechanical impact during installation to preserve probe alignment accuracy and housing integrity.\u003c\/p\u003e\n\u003cp\u003eUse appropriate sealing practices on NPT threads to prevent fluid ingress in turbine and compressor environments.\u003c\/p\u003e\n\u003cp\u003eInspect housing periodically in high-vibration machinery to ensure long-term mechanical stability.\u003c\/p\u003e\n\u003cp\u003eEnsure consistent grounding practices to reduce electrical noise in proximity measurement signals.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321137003,"sku":"21000-28-10-0-41-04-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/21000-28-10-0-41-04-02-sx5o0jx4jww_8c8e3708-d83a-4c0f-91b4-f739d7a5557e.jpg?v=1765521146"},{"product_id":"bently-nevada-190501-00-00-00-velomitor-ct-velocity-transducer-1","title":"Bently Nevada 190501-00-00-00 Velomitor CT Velocity Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 190501-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Velomitor CT velocity transducer designed for continuous vibration monitoring of industrial rotating machinery such as pumps, fans, compressors, motors, and auxiliary equipment. It provides direct velocity output for condition monitoring systems used in power generation, oil and gas, and process industries.\u003c\/p\u003e\n\u003cp\u003eThe sensor is engineered for reliable operation in general-purpose machinery protection applications where compact installation and stable long-term vibration measurement are required. It converts mechanical vibration into a proportional velocity signal suitable for PLC, DCS, and dedicated vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe MIL-C-5015 connection interface ensures robust electrical connectivity in industrial environments with high vibration, thermal cycling, and electrical noise exposure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e190501\u003c\/td\u003e\n\u003ctd\u003eVelomitor CT velocity transducer series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo stud mounting hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eMIL-C-5015 electrical connector interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines mechanical mounting configuration, electrical interface type, and certification scope within the Velomitor CT platform.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e190501-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.297 kg (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVelocity transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMIL-C-5015 interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003eNo stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eVelocity vibration signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eIndustrial PLC, DCS, and vibration systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe Velomitor CT is designed for direct velocity measurement, eliminating the need for external integration or signal conversion in most monitoring systems. This simplifies system architecture in general-purpose machinery protection applications.\u003c\/p\u003e\n\u003cp\u003eThe MIL-C-5015 connector provides rugged electrical connection suitable for industrial environments with continuous vibration and electrical interference.\u003c\/p\u003e\n\u003cp\u003eThe no-stud configuration allows flexible installation using application-specific mounting methods depending on machine housing design.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this sensor typically used?\u003c\/strong\u003e\u003cbr\u003eIt is used in pumps, fans, compressors, and general industrial rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of velocity output?\u003c\/strong\u003e\u003cbr\u003eIt provides direct vibration velocity measurement without additional signal conversion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it replace proximity probes?\u003c\/strong\u003e\u003cbr\u003eNo. It is used for general vibration monitoring, not shaft displacement measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs MIL-C-5015 important?\u003c\/strong\u003e\u003cbr\u003eYes. It ensures secure and reliable electrical connection in harsh industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure firm mechanical coupling between sensor and machine surface to achieve accurate vibration transmission.\u003c\/p\u003e\n\u003cp\u003eAvoid loose mounting conditions, as poor coupling directly affects measurement accuracy and signal stability.\u003c\/p\u003e\n\u003cp\u003eRoute signal cables away from high-voltage and VFD output wiring to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eVerify connector locking during installation to prevent intermittent signal loss in high-vibration environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eInstall sensor on rigid machine surfaces to avoid resonance amplification effects in measurement readings.\u003c\/p\u003e\n\u003cp\u003eMaintain proper grounding practices within the monitoring system to reduce electrical noise interference.\u003c\/p\u003e\n\u003cp\u003eAvoid installing in areas with structural flexibility, as this may distort vibration measurement accuracy.\u003c\/p\u003e\n\u003cp\u003ePerform periodic inspection in high-vibration applications to ensure long-term mounting integrity.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321169771,"sku":"190501-00-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-190501-00-00-00-velomitor-ct-velocity-transducer-fgw3fgaxwrd_898b573d-f721-4202-a1ec-90d2c3b0ddd3.jpg?v=1765449534"},{"product_id":"bently-nevada-24701-16-05-00-073-04-02-proximity-probe-housing-assembly","title":"Bently Nevada 24701-16-05-00-073-04-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 24701-16-05-00-073-04-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a proximity probe housing assembly designed for secure installation of 3300 XL 8 mm proximity probes in rotating machinery monitoring applications. It is widely applied in turbines, compressors, pumps, and industrial drivetrains where stable probe positioning is required for accurate vibration and shaft displacement measurement.\u003c\/p\u003e\n\u003cp\u003eThis housing assembly provides a mechanically stable interface between the probe and machine casing. It ensures consistent probe penetration depth and alignment, which directly affects signal accuracy in eddy-current measurement systems. The configuration supports harsh industrial environments where vibration, thermal expansion, and mechanical stress are continuous operating conditions.\u003c\/p\u003e\n\u003cp\u003eThe 3\/4-14 NPT mounting interface ensures compatibility with standard industrial threaded ports, making it suitable for both OEM installations and retrofit monitoring upgrades.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e24701\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003eCompatible 3300 XL 8 mm probe option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 m probe cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e073\u003c\/td\u003e\n\u003ctd\u003e7.3 in probe penetration depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT plug configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach segment defines probe compatibility, installation geometry, penetration depth, and mechanical interface configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e24701-16-05-00-073-04-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Probe\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration\u003c\/td\u003e\n\u003ctd\u003e7.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandoff Adapter\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFittings\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and shaft displacement monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis housing assembly ensures fixed mechanical positioning of proximity probes in applications where probe stability directly affects measurement accuracy. It is designed to eliminate installation drift caused by vibration or thermal expansion in machinery environments.\u003c\/p\u003e\n\u003cp\u003eThe defined penetration depth standardizes probe positioning relative to the target surface, which is critical for maintaining consistent gap voltage in eddy-current measurement systems.\u003c\/p\u003e\n\u003cp\u003eNPT threaded interface allows direct installation into machine housings without custom adapters, simplifying field deployment and maintenance procedures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this housing used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and industrial rotating equipment requiring stable proximity probe installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is penetration depth important?\u003c\/strong\u003e\u003cbr\u003eIt ensures correct probe-to-target distance for accurate vibration signal generation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with non-3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed specifically for Bently Nevada 3300 XL 8 mm probes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of NPT mounting?\u003c\/strong\u003e\u003cbr\u003eIt provides standardized mechanical integration into industrial equipment housings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct torque application during NPT thread installation to avoid misalignment or mechanical stress on the housing body.\u003c\/p\u003e\n\u003cp\u003eVerify probe penetration depth before commissioning to maintain correct gap calibration in the measurement system.\u003c\/p\u003e\n\u003cp\u003eMaintain clean internal housing surfaces to avoid debris interference with probe alignment and signal accuracy.\u003c\/p\u003e\n\u003cp\u003eRoute probe cable away from high-voltage and VFD wiring to minimize electromagnetic interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eAvoid mechanical shock during installation, as it may affect probe alignment and penetration accuracy.\u003c\/p\u003e\n\u003cp\u003eUse proper sealing practices on NPT threads to prevent oil or gas ingress in turbine environments.\u003c\/p\u003e\n\u003cp\u003eInspect housing periodically in high-vibration machinery to ensure mechanical stability over long operating cycles.\u003c\/p\u003e\n\u003cp\u003eEnsure consistent grounding practices to reduce electrical noise in proximity measurement signals.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321202539,"sku":"24701-16-05-00-073-04-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/24701-16-05-00-073-04-02-peopwauugbn_0a2a054b-bea6-489f-ab4d-dc7701387c7d.jpg?v=1765521149"},{"product_id":"149032-03-bently-nevada-3300-xl-proximitor-sensor-9-0m-system","title":"149032-03 Bently Nevada 3300 XL Proximitor® Sensor (9.0m System)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e149032-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a foundational component of the Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Proximity Transducer System\u003c\/strong\u003e. This Proximitor® Sensor acts as the sophisticated signal conditioning brain for eddy current probes. It performs two critical functions: it generates the high-frequency Radio Frequency (RF) signal that excites the probe tip and subsequently converts the returned modulated signal into a usable voltage output.\u003c\/p\u003e\n\u003cp\u003eSpecifically calibrated for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0-meter total system length\u003c\/strong\u003e, the 149032-03 delivers a highly linear 7.87 V\/mm (200 mV\/mil) output proportional to the distance between the probe tip and the observed metal surface. This allows for the non-contact measurement of both static displacement (thrust\/position) and dynamic vibration in high-criticality rotating machinery, including steam turbines, centrifugal compressors, and large-scale industrial motors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e149032-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration is engineered for seamless integration into 3500 Monitoring Systems or standalone PLC\/DCS architectures.\u003c\/p\u003e\n\u003ch3\u003eSystem Length Calibration (03)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption indicates a factory calibration for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0-meter (29.5 feet)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etotal system length. To maintain the specified accuracy and Scale Factor, the combined length of the proximity probe and the extension cable must exactly total 9.0 meters.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL hardware architecture provides superior suppression of \"radio frequency interference\" (RFI). This ensures that the vibration data remains clean even when the sensor is mounted in proximity to high-voltage motor starters or communication equipment.\u003c\/p\u003e\n\u003ch3\u003eRugged Physical Build\u003c\/h3\u003e\n\u003cp\u003eConstructed with a high-grade zinc-plated or aluminum housing, the 149032-03 resists corrosion and provides a robust shielding against electromagnetic noise. The internal electronics are fully encapsulated to prevent failure from moisture or vibration within the local instrument enclosure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 Meters (Total Probe + Extension)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-17.5 VDC to -26 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Sensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 Hz (DC) to 10 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +100°C (-60°F to +212°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.25 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Proximitor® Sensor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers significant technical improvements over legacy 3300 and 7200 series models:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Interchangeability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 149032-03 allows for the replacement of probes or cables without the need for on-site recalibration, provided the total system length remains at 9.0 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImproved Scale Factor Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal circuitry compensates for temperature variations, ensuring that a vibration reading in the heat of summer is just as accurate as one in the dead of winter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelf-Diagnostic Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe sensor maintains a consistent \"Not OK\" status if the probe circuit is broken or shorted, preventing the monitoring system from providing false \"zero-vibration\" data during a sensor failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cp\u003eSuccessful deployment depends on correct electrical grounding and physical mounting.\u003c\/p\u003e\n\u003ch3\u003eMounting and Isolation\u003c\/h3\u003e\n\u003cp\u003eMount the Proximitor® on a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor directly to a backplate. For optimal performance, ensure the sensor housing is electrically isolated from the machine ground to prevent ground loops. Use the factory-supplied isolation washers if mounting to a metal plate.\u003c\/p\u003e\n\u003ch3\u003ePower and Signal Wiring\u003c\/h3\u003e\n\u003cp\u003eUse high-quality shielded, twisted-pair cable for the connection between the 149032-03 and the monitoring rack. Connect the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-VT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Voltage Terminal),\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Common), and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Signal) terminals precisely. Ensure the shield is grounded at the monitor end only.\u003c\/p\u003e\n\u003ch3\u003eField Verification\u003c\/h3\u003e\n\u003cp\u003eAfter installation, verify the \"Gap Voltage\" at the PROXIMITOR test points. For a standard 8mm probe, a reading of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-10.0 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates the probe is positioned at the center of its linear range, providing maximum headroom for both vibration and thrust measurements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use the 149032-03 with a 5.0-meter cable system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The 149032-03 is specifically calibrated for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0-meter system\u003c\/strong\u003e. Using a 5.0-meter setup will cause a significant Scale Factor error, resulting in vibration readings that are inaccurate by 20% or more. Always match the Proximitor® to your total cable length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the difference between the 149032 series and the older 330180 Proximitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The 149032 is the updated 3300 XL Proximitor® Sensor. While they share similar footprints, the 149032 offers better RFI immunity and improved thermal stability. It is a direct functional replacement for the older 330180-series modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this sensor require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. It requires a stable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower source (standard for Bently Nevada systems). This power is usually provided directly from the 3500\/M or 3701\/M monitoring rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the 149032-03 compatible with 11mm or NSv probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: No. This specific model is designed for use with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL 8mm probes\u003c\/strong\u003e. 11mm and NSv systems require their own dedicated Proximitor® models due to differences in tip diameter and electrical impedance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325724523,"sku":"149032-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/149032-03-1p4kzakxebm_8577a64c-5a3b-4077-80dd-0ee36d623830.jpg?v=1765521305"},{"product_id":"abb-3asd299001b2-ypq-201t-computer-board","title":"ABB 3ASD299001B2 YPQ 201T Computer Board","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYPQ 201T\u003c\/strong\u003e is a computer board engineered for integration into legacy medium voltage drive systems. It functions as a core processing component within ABB drive platforms, executing control logic and system monitoring tasks. This module supports the operational architecture of DC drive systems and TYRAK LCI converters. The board interfaces directly with the drive’s internal bus structure to manage power semiconductor switching sequences and system diagnostics. Typical deployment includes industrial motor control centers requiring high-reliability processing units. Compatibility extends to ABB \u003cstrong\u003eYGMV\u003c\/strong\u003e, \u003cstrong\u003eYGMW\u003c\/strong\u003e, \u003cstrong\u003eYHMV\u003c\/strong\u003e, \u003cstrong\u003eYHMW\u003c\/strong\u003e, and \u003cstrong\u003eTYRAK LCI\u003c\/strong\u003e series equipment.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNew production part status\u003c\/li\u003e\n\u003cli\u003eDirect replacement for legacy drive systems\u003c\/li\u003e\n\u003cli\u003eConfigured for ABB proprietary drive architectures\u003c\/li\u003e\n\u003cli\u003eNet weight 1.56 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRetrofit of ABB legacy DC drive systems\u003c\/li\u003e\n\u003cli\u003eMaintenance of TYRAK LCI medium voltage AC drives\u003c\/li\u003e\n\u003cli\u003eIndustrial motor control in mining and metals processing\u003c\/li\u003e\n\u003cli\u003ePower conversion systems in heavy manufacturing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3ASD299001B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Product ID\u003c\/td\u003e\n\u003ctd\u003eEXC3ASD299001B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInvoice Description\u003c\/td\u003e\n\u003ctd\u003eYPQ 201T COMPUTER BOARD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e84733020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Order Quantity\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Multiple\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMade To Order\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Type\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e1.56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eNot specified in source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure electrostatic discharge (ESD) precautions are observed during handling.\u003c\/li\u003e\n\u003cli\u003eVerify that the drive system is fully de-energized and locked out prior to installation.\u003c\/li\u003e\n\u003cli\u003eConfirm compatibility with existing YPQ series backplanes before insertion.\u003c\/li\u003e\n\u003cli\u003eSecure the board according to the host drive cabinet specifications.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance for ventilation as per the overall drive system design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this board compatible with current ABB ACS drives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis computer board is designated for legacy DC drives and TYRAK LCI systems, not for modern ACS platform compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 3ASD299001B2 and EXC3ASD299001B2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number EXC3ASD299001B2 represents the replacement product ID for the original 3ASD299001B2 board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this board be used as a spare part for YGMV drives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is listed under parts for YGMV, YGMW, YHMV, and YHMW legacy DC drives.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the board require specific firmware loading?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirmware compatibility is dependent on the specific drive system configuration; consult the drive documentation for software requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the product new or refurbished?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part type is specified as new.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the lead time for this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs a made-to-order item marked \"No\", it is typically available from stock or standard distribution channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre technical manuals included with the purchase?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDocumentation must be sourced from ABB official resources based on the YPQ 201T designation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the physical weight of the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe net weight is 1.56 kilograms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this board myself?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation should only be performed by qualified personnel familiar with ABB drive systems and high-voltage safety procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this board suitable for hazardous locations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo hazardous area certifications are specified in the provided data; it is intended for general industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the YPQ 201T?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt serves as a computer board responsible for processing and control functions within the drive.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this include mounting hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMounting hardware is typically supplied with the drive chassis, not the individual board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify if my drive uses this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the bill of materials for your specific drive model against the product ID 3ASD299001B2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs international shipping available for this part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipping depends on the supplier's logistics capabilities and the destination country's import regulations for electronic components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the tariff code for customs clearance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Harmonized System code is 84733020.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668498805099,"sku":"3ASD299001B2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-ypq201t-3asd299001b2-computer-control-module-nroghmxxt3y_9967f97c-ea08-4bad-93d4-a0d78fbe2eb5.jpg?v=1765532498"},{"product_id":"abb-dspa-110-57520001-p-masterview-800-display-processor","title":"ABB DSPA 110 57520001-P MasterView 800 Display Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Product ID:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e57520001-P\u003c\/strong\u003e) is a legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial display processor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused in the ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAdvant Master \/ MasterView 800\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperator interface system.\u003c\/p\u003e\n\u003cp\u003eIt functions as a central computing and graphical processing unit within the Advant OCS architecture, responsible for rendering real-time process visualization and managing operator console communication. The module converts incoming control system telemetry into visual process displays for plant operation and monitoring.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for integration with ABB Advant Master systems used in large-scale industrial automation environments such as power plants, oil \u0026amp; gas facilities, and process control centers.\u003c\/p\u003e\n\u003cp\u003eThis module is classified as a legacy system component and is primarily used for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaintenance, spare replacement, and system lifecycle extension\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edisplay processor board for Advant MasterView 800\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAdvant OCS control system architecture\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess visualization processing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports operator console communication interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoard-level\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral unit accessory module\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for legacy industrial control system maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with Advant Master system hardware racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable operation in continuous industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e57520001-P\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eAdvant OCS \/ MasterView 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDisplay Processor Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Role\u003c\/td\u003e\n\u003ctd\u003eCentral Unit \/ Operator Interface Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial control visualization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e238.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e27.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e234.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eSystem Function and Operation\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110 display processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a graphical processing module within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAdvant Master control system\u003c\/strong\u003e. It receives real-time process data from core controllers and translates it into operator interface visualizations.\u003c\/p\u003e\n\u003cp\u003eThe module plays a key role in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess monitoring display rendering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperator console communication handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time telemetry visualization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem-level interface coordination within Advant MasterView 800\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt does not function as a standalone controller but as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem-level interface processor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Handling Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a board-level module designed for installation inside Advant system sub-racks.\u003c\/p\u003e\n\u003cp\u003eProper handling requirements include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse grounded\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESD protection equipment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign module carefully with backplane guide rails\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure proper seating to avoid backplane pin damage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure front panel screws to prevent vibration loosening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIncorrect installation may lead to communication failure or backplane damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eElectrical and EMC Considerations\u003c\/h3\u003e\n\u003cp\u003eStable operation depends on correct grounding and shielding practices.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSub-rack chassis must be bonded to cabinet functional earth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse low-impedance copper braid for grounding connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure all communication and video cables use shielded routing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain proper separation between signal and power wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProper EMC design ensures stable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edisplay rendering and communication performance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThermal Management\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelies on passive cooling through natural convection.\u003c\/p\u003e\n\u003cp\u003eTo maintain safe operation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain minimum 50 mm vertical airflow clearance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid overcrowding adjacent card slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall forced ventilation if cabinet temperature exceeds 45°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure consistent airflow across sub-rack assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eABB Advant Master control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMasterView 800 operator interface stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas process control environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial DCS legacy system maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong-life-cycle industrial automation infrastructures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct ID:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e57520001-P\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eABB Type Designation:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: Advant Master \/ MasterView 800\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCategory: Legacy control system display processor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the DSPA 110 module?\u003c\/strong\u003e\u003cbr\u003eIt is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edisplay processor board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused to render process visualization in ABB Advant Master systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan DSPA 110 be replaced with DSPB 120?\u003c\/strong\u003e\u003cbr\u003eNot directly. Although they are related, they differ in revision, memory configuration, and firmware compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be hot-swapped?\u003c\/strong\u003e\u003cbr\u003eNo. Power must be isolated before removal to avoid backplane or system damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is this a legacy component?\u003c\/strong\u003e\u003cbr\u003eIt belongs to the ABB Advant MasterView 800 system, which is a previous-generation industrial control architecture still used in long-life installations.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668514238827,"sku":"DSCA120 57520001-P","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-dsca120-57520001-p-advanced-industrial-communications-board-gfigrvlx15v_a1a5e3cd-a789-48f7-846a-96cabda556f9.jpg?v=1765532616"},{"product_id":"abb-fs300r12ke3-agdr-72c-industrial-igbt-and-gate-driver-assembly","title":"ABB FS300R12KE3\/AGDR-72C Industrial IGBT and Gate Driver Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB \u003cstrong\u003eFS300R12KE3 \/ AGDR-72C\u003c\/strong\u003e (Product ID: \u003cstrong\u003e68569541\u003c\/strong\u003e) is a high-power \u003cstrong\u003eIGBT module and gate driver assembly kit\u003c\/strong\u003e designed for industrial \u003cstrong\u003ethree-phase inverter systems\u003c\/strong\u003e and variable frequency drives.\u003c\/p\u003e\n\u003cp\u003eThis matched system combines the \u003cstrong\u003eInfineon TRENCHSTOP™ FS300R12KE3 IGBT3 power module\u003c\/strong\u003e with the \u003cstrong\u003eABB AGDR-72C gate driver board\u003c\/strong\u003e, delivering stable switching performance in demanding \u003cstrong\u003eindustrial motor control applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe assembly is widely used in \u003cstrong\u003eABB ACS800 drive platforms\u003c\/strong\u003e, where it handles high-current switching, real-time protection, and precise motor modulation. The \u003cstrong\u003eAGDR-72C driver board\u003c\/strong\u003e mounts directly onto the IGBT terminals, ensuring a low-inductance connection path that reduces switching noise and improves system reliability.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMatched \u003cstrong\u003eIGBT module + gate driver board kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFS300R12KE3 1200V TRENCHSTOP™ IGBT3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-performance \u003cstrong\u003eAGDR-72C gate driver board\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for \u003cstrong\u003eABB ACS800 industrial drive systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated \u003cstrong\u003edesaturation short-circuit protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh switching capability up to \u003cstrong\u003e20 kHz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized low-inductance gate interface design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for high-power \u003cstrong\u003eindustrial inverter applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFS300R12KE3 \/ AGDR-72C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e68569541\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Code\u003c\/td\u003e\n\u003ctd\u003e3AUA0000109336\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIGBT Module + Gate Driver Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGBT Technology\u003c\/td\u003e\n\u003ctd\u003eInfineon \u003cstrong\u003eTRENCHSTOP™ IGBT3\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1200 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCollector Current\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e300 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e600 A (1 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003eUp to \u003cstrong\u003e20 kHz\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate-Emitter Voltage\u003c\/td\u003e\n\u003ctd\u003e±20 V max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e2500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSaturation Voltage\u003c\/td\u003e\n\u003ctd\u003e1.70–2.15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e21 × 175 × 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany \/ Estonia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85359000 \/ 85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eSystem Function and Operation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFS300R12KE3 IGBT module\u003c\/strong\u003e performs high-power switching in inverter bridge circuits, while the \u003cstrong\u003eAGDR-72C gate driver board\u003c\/strong\u003e ensures accurate gate signal control and fast fault response.\u003c\/p\u003e\n\u003cp\u003eThe driver provides real-time protection functions including:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDesaturation monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-circuit detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSoft turn-off control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGate voltage supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese functions protect the power stage during abnormal load or motor fault conditions in \u003cstrong\u003ehigh-power inverter systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThermal Management and Installation\u003c\/h3\u003e\n\u003cp\u003eProper thermal design is critical for stable operation of the \u003cstrong\u003eIGBT power module assembly\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBefore installation:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eClean heatsink and baseplate using non-residue solvent\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply uniform \u003cstrong\u003ethermal interface material (TIM)\u003c\/strong\u003e layer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure even pressure distribution during mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRecommended torque sequence:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInitial tightening: 2.0 Nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal torque: 3.0–6.0 Nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis ensures stable heat transfer under continuous high-load operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eRibbon Cable and System Compatibility\u003c\/h3\u003e\n\u003cp\u003eWhen replacing the \u003cstrong\u003eFS300R12KE3 \/ AGDR-72C assembly\u003c\/strong\u003e, it is recommended to replace associated control ribbon cables to ensure signal integrity.\u003c\/p\u003e\n\u003cp\u003eCommon configurations include:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eR7i frame systems: Code \u003cstrong\u003e68869625\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eR8i dual-IGBT systems: Code \u003cstrong\u003e68870089\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eR8i triple-IGBT systems: Code \u003cstrong\u003e68692172\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing aged ribbon cables may increase the risk of \u003cstrong\u003egate signal distortion and communication faults\u003c\/strong\u003e in the inverter stack.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eESD and Handling Requirements\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAGDR-72C gate driver board\u003c\/strong\u003e contains sensitive control electronics including optical isolation and high-density logic circuits.\u003c\/p\u003e\n\u003cp\u003eHandling requirements:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse grounded \u003cstrong\u003eESD wrist protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDischarge DC bus capacitors before installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid direct contact with PCB components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify control rail stability before activation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIncorrect handling may cause permanent damage to the gate driver circuitry.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe ABB \u003cstrong\u003eFS300R12KE3 \/ AGDR-72C\u003c\/strong\u003e is used in:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eABB ACS800 industrial drive systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-power motor control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial frequency converters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWind power inverter systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy-duty automation drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial UPS power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct ID: \u003cstrong\u003e68569541\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement Code: \u003cstrong\u003e3AUA0000109336\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType: \u003cstrong\u003eFS300R12KE3 \/ AGDR-72C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCategory: IGBT power module + gate driver kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 85359000 \/ 85389091\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between AGDR-72C and AGDR-62C?\u003c\/strong\u003e\u003cbr\u003eThey differ in layout, gate resistance design, and thermal\/mechanical configuration. They are not universally interchangeable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this kit include protection functions?\u003c\/strong\u003e\u003cbr\u003eYes. The \u003cstrong\u003eAGDR-72C driver\u003c\/strong\u003e includes desaturation detection and fast fault shutdown mechanisms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan old ribbon cables be reused?\u003c\/strong\u003e\u003cbr\u003eIt is not recommended. Aging cables can introduce resistance drift and timing instability in gate signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668514533739,"sku":"FS300R12KE3\/AGDR-72C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-fs300r12ke3-agdr-72c-igbt-module-kit-bbdzgj2qjua_c1729b66-646a-4b5c-a1f2-b884b8879c10.jpg?v=1765532628"},{"product_id":"abb-xv-c772-a102-3bhe032285r0102-medium-voltage-drive-hvd-board","title":"ABB XV C772 A102 3BHE032285R0102 Medium Voltage Drive HVD Board","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-216\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-216\"\u003eThe ABB \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-216\"\u003eXV C772 A102\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-216\"\u003e ( \u003cstrong\u003eXVC772A102\u003c\/strong\u003e ,Product ID: \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-216\"\u003e3BHE032285R0102\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-216\"\u003e) is a specialized high-voltage detection (HVD) printed circuit board assembly \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-216 citation-end-216\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-215\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eengineered for the raw signal acquisition layer of medium voltage (MV) AC drives\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-215 citation-end-215\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-214\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThis crucial hardware asset integrates directly into the power cells of ABB ACS 2000 and water-cooled ACS 5000 industrial drive topologies\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-214 citation-end-214\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. Deployed in ultra-critical process systems such as deep-shaft mine winders, high-output power station induced draft fans, and large-scale petrochemical refinery compressors, any failure in high-voltage sensing risks catastrophic power cell faults or systemic control loop loss. The \u003cstrong\u003eXV C772 A102\u003c\/strong\u003e incorporates highly responsive, isolated voltage attenuation networks that convert bulk DC link and AC phase levels into low-voltage telemetry. By establishing high-speed, continuous diagnostic observation of cell voltage vectors, this module prevents harmonic grid imbalance and minimizes costly operational equipment downtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eEnvironmental Engineering \u0026amp; Board Topology\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe physical architecture of the \u003cstrong\u003eXV C772 A102\u003c\/strong\u003e interface card is optimized to endure the extreme electrical stress fields inherent to medium voltage multi-level inverter circuits. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-213\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eTo ensure physical and electrical isolation performance over long field life cycles, the assembly is factory-treated with a heavy, professional-grade protective varnished finish\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-213 citation-end-213\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. This specialized conformal coating prevents microscopic track tracking, moisture-induced bridging, and ionic dust condensation across close-pitched high-voltage trace boundaries. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-212\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eMechanically tracking at a net weight of 0.2 kg\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-212 citation-end-212\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e, the layout minimizes high-mass component footprints to defend internal traces against long-term, low-frequency structural equipment vibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCertified Product Data Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Factory Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-211\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eXV C772 A102\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-211 citation-end-211\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct ID\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-210\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e3BHE032285R0102\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-210 citation-end-210\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-209\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-209 citation-end-209\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturing Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-208\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eChina (CN)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-208 citation-end-208\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBoard Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-207\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eHigh-Voltage Detection (HVD) Board\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-207 citation-end-207\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComponent Finish\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-206\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eHeavily Varnished \/ Conformal Coated\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-206 citation-end-206\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCore Drive Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-205\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eACS 2000 \/ ACS 5000 Water Cooled Series\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-205 citation-end-205\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDrive Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-204\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eMedium Voltage AC Industrial\/Special Purpose Drives\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-204 citation-end-204\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-203\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-203 citation-end-203\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Order Quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-202\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e1 piece\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-202 citation-end-202\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCustoms Tariff Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-201\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e85049099\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-201 citation-end-201\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C (Internal module enclosure limit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated passive\/low-power active sensing networks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInfrastructure Diagnostics \u0026amp; Maintenance FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat is the functional purpose of the factory varnished finish on this specific HVD board?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-200\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eThe varnished finish \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-200 citation-end-200\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eacts as a high-dielectric conformal coating layer. In heavy industrial environments like underground mining and mineral processing, ambient air contains high volumes of conductive dust and moisture. The varnish layer seals the fine copper tracks and surface-mount components, preventing tracking current paths and localized high-voltage arcing across the board surface.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCan this component be swapped interchangeably between the ACS 2000 and the ACS 5000 drives?\u003c\/strong\u003eYes. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-199\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eAccording to the original manufacturer part reference data, the 3BHE032285R0102 board is certified for direct spare part deployment in both the ACS 2000 drive chassis and the water-cooled ACS 5000 drive platform\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-199 citation-end-199\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. Field technicians must always verify matching software revision indices on the master control unit during hardware replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this high-voltage detection board require external voltage calibration after field installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The XV C772 A102 is manufactured with low-tolerance precision attenuation resistors to ensure consistent accuracy out of the box. The drive control software manages minor parameter offsets during its automated boot-up self-test and hardware validation sequence.\u003c\/p\u003e\n\u003ch3\u003eField Replacement Protocols \u0026amp; Electrical Safety Procedures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Discharge Verification and Lockout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore opening the phase module or accessing the internal electronics bay of the medium voltage drive, isolate the entire drive assembly from the primary grid supply. Initiate the mandatory discharge sequence and verify via the drive's mechanical earthing switch and a calibrated high-voltage multimeter that the DC bus voltage has dropped fully to 0 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrostatic Discharge Handling Rules:\u003c\/strong\u003e The low-voltage signaling chips integrated alongside the high-voltage resistors are highly vulnerable to static puncture. Maintenance personnel must wear a properly grounded ESD wrist strap before unboxing or touching the card. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-198\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eHold the board exclusively by its non-conductive edges to avoid disrupting the protective varnish finish\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-198 citation-end-198\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAttaching Fiber-Optic or Ribbon Signal Leads:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInspect the optical or low-voltage ribbon connectors for dust or grease before plugging them into the card interfaces. Ensure that lock clips click into place firmly; clean, high-pressure signal connections are vital to avoid data packet loss and prevent the control unit from triggering a false high-voltage trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRetaining Bolt Tightening Adjustments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMount the board onto its dedicated insulated tracking standoffs within the power cell. Tighten all mechanical M4 plastic or metal retaining screws to an engineered torque of 0.8 N-m. Avoid uneven tightening, as twisting or flexing the card can fracture internal multi-layer ceramic sensing capacitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668516794731,"sku":"3BHE032285R0102","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-xvc772a102-3bhe032285r0102-hvd-board-bfi0juki43b_1aaa854d-f0f4-4b1b-b37b-109184f6a66d.jpg?v=1765532692"}],"url":"https:\/\/www.plcprotech.com\/collections\/new-arrivals.oembed?page=13","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}