{"title":"Norgren","description":"\u003cp\u003e\u003cstrong\u003eNorgren\u003c\/strong\u003e\u003cspan\u003e is a global leader in motion and fluid control technologies, providing highly engineered solutions for critical industrial automation requirements. This collection features a comprehensive range of Norgren components, centered around their industry-standard \u003c\/span\u003e\u003cstrong\u003eair preparation systems\u003c\/strong\u003e\u003cspan\u003e, such as the \u003c\/span\u003e\u003cstrong\u003eExcelon\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003eOlympian Plus\u003c\/strong\u003e\u003cspan\u003e series, which integrate filters, regulators, and lubricators (FRLs). To ensure precise flow management, we offer \u003c\/span\u003e\u003cstrong\u003eNorgren Solenoid Valves\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003eDirectional Control Valves\u003c\/strong\u003e\u003cspan\u003e designed for high-cycle reliability, alongside a robust selection of \u003c\/span\u003e\u003cstrong\u003ePneumatic Cylinders\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003eActuators\u003c\/strong\u003e\u003cspan\u003e for motion control. For monitoring and safety, the series includes high-precision \u003c\/span\u003e\u003cstrong\u003ePressure Switches\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003eProportional Valves\u003c\/strong\u003e\u003cspan\u003e that maintain system stability in demanding environments. All Norgren products at \u003c\/span\u003e\u003cstrong\u003ePLCProTech\u003c\/strong\u003e\u003cspan\u003e are factory-sealed to guarantee technical performance and longevity in factory automation and process control applications.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"b68g-nnt-mr3-nsn-norgren-olympian-plus-filter-regulator","title":"B68G-NNT-MR3-NSN | Norgren | Olympian Plus Filter\/Regulator","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNorgren B68G-NNT-MR3-NSN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity filter\/regulator from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOlympian Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries, specifically configured for high-pressure industrial applications. This model is distinguished by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNon-Relieving\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ediaphragm and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT-bar\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadjustment, making it ideal for systems where downstream pressure must be maintained or where venting of gases into the atmosphere is not permitted.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNorgren\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOlympian Plus (B68)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiltration Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e40µm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 to 250 psig (0.7 to 17 bar)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustment Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eT-bar\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiaphragm Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Relieving\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBowl Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Pint (0.5 Liter) with Liquid Level Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo Yoke (NN Configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eKey Component Codes\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT-bar (T):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides the necessary leverage to adjust the heavy-duty spring required for the 17-bar pressure range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Relieving (N):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard models, this unit does not vent downstream air when the set pressure is reduced. It is preferred for applications involving neutral gases or where pressure stability in a dead-end circuit is critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Bowl (G\/R):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a large capacity with a clear indicator to monitor condensate levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eYoke Requirement\u003c\/strong\u003e: This is a \"basic\" unit (\u003cstrong\u003eNo Yoke\u003c\/strong\u003e). To install, it must be plugged into a pre-installed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB68 Olympian Plus Yoke\u003c\/strong\u003e. This allows for \"quarter-turn\" installation and removal without breaking the pipework.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Orientation\u003c\/strong\u003e: Verify the direction of airflow marked on the body. Install vertically with the bowl facing down.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDownstream Pressure Relief\u003c\/strong\u003e: Because this is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNon-Relieving\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodel, if you lower the pressure setting while the system is closed, the downstream pressure will\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edrop automatically. You must manually vent the downstream air to reach the new lower set point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Space\u003c\/strong\u003e: Ensure at least 150mm of clearance below the bowl for manual draining and filter element replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQs)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should I use a Non-Relieving diaphragm?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNon-relieving regulators are used when you want to avoid air venting from the regulator body (e.g., in cleanrooms or when using inert gases) or when the application requires the downstream pressure to remain \"trapped\" until consumed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the 40µm element?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 40µm element provides excellent flow rates with minimal pressure drop, making it the standard choice for general-purpose industrial air tools and machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I convert this to an automatic drain?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the manual drain can be replaced with a Norgren auto-drain kit if the unit is located in a hard-to-reach area or if high moisture levels are present.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat gauge should I use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince this unit supports up to 17 bar (250 psig), ensure you select a gauge with a scale that exceeds 17 bar (typically a 0-25 bar or 0-400 psi gauge) for accurate monitoring.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Norgren","offers":[{"title":"Default Title","offer_id":53077916418411,"sku":"B68G-NNT-MR3-NSN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/b68g-nnt-mr3-nsn-gajrpl00tew.jpg?v=1775733456"},{"product_id":"b68g-nnt-mr1-rsn-norgren-olympian-plus-filter-regulator","title":"B68G-NNT-MR1-RSN | Norgren | Olympian Plus Filter\/Regulator","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNorgren B68G-NNT-MR1-RSN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-pressure, high-precision filter\/regulator from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOlympian Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. This specific configuration is designed for heavy-duty industrial applications requiring fine filtration (\u003cstrong\u003e5µm\u003c\/strong\u003e) and high-end pressure control (up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e17 bar\u003c\/strong\u003e), featuring a T-bar adjustment for ease of use under high torque.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNorgren\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOlympian Plus Filter\/Regulator (B68)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFiltration Element\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5µm\u003c\/strong\u003e (High Precision)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e10 to 250 psig (0.7 to 17 bar)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAdjustment Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eT-bar\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBowl Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Pint (0.5 Liter) with Liquid Level Indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDrain Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiaphragm Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelieving\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Yoke (NN Configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFunctional Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Bowl (G):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a liquid level indicator for easy visual monitoring of condensate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT-bar Adjustment (T):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides extra leverage, making it easier to adjust outlet pressure, especially at the higher end of the 17-bar range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFine Filtration (1):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5µm element removes significantly smaller particles than standard 40µm filters, protecting sensitive downstream equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eYoke Mounting\u003c\/strong\u003e: This unit is a \"Basic\" model (Code: NN) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erequires an Olympian Plus B68 yoke\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor installation. The yoke remains in the pipework, allowing the filter\/regulator to be plugged in or removed in seconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrientation\u003c\/strong\u003e: Mount the unit vertically with the bowl facing downward. Ensure there is at least 150mm of clearance below the bowl for manual draining and filter element maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Safety\u003c\/strong\u003e: Given the high maximum pressure (17 bar), ensure all downstream piping, hoses, and tools are rated for the intended operating pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelieving Function\u003c\/strong\u003e: This is a relieving regulator. When the downstream pressure is adjusted from a high to a low setting, excess air will be exhausted through the regulator body. Do not block the vent hole.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQs)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does this model use a T-bar instead of a standard knob?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe T-bar is used for the \"S\" pressure range (up to 17 bar). At higher pressures, the internal spring tension is much stronger; the T-bar provides the necessary leverage for the operator to make precise adjustments comfortably.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs a 5µm filter element restrictive to airflow?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile a 5µm element provides cleaner air, it does create a slightly higher pressure drop than a 40µm element. Ensure your compressor capacity accounts for this if running high-flow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install a gauge on this unit later?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Although this model is coded \"N\" (Without Gauge), the body features gauge ports (usually 1\/8\" or 1\/4\" NPT\/ISO G). You can remove the port plug and install a standard back-mount pressure gauge at any time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance is required for the manual drain?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drain should be opened periodically to expel collected water and oil. If the liquid level reaches the \"Max\" line on the indicator, it can cause moisture carryover into the air line.\u003c\/p\u003e","brand":"Norgren","offers":[{"title":"Default Title","offer_id":53077930443115,"sku":"B68G-NNT-MR1-RSN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/b68g-nnt-mr1-rsn-zgymyqx5nwv.jpg?v=1775733454"},{"product_id":"b68g-nnk-mr3-rln-norgren-olympian-plus-filter-regulator","title":"B68G-NNK-MR3-RLN | Norgren | Olympian Plus Filter\/Regulator","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNorgren B68G-NNK-MR3-RLN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity filter\/regulator (piggyback) unit from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOlympian Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. This series is known for its unique plug-in design, allowing for rapid installation and maintenance without disturbing the pipework, provided a compatible yoke is used.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNorgren\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOlympian Plus Filter\/Regulator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBody Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB68 (High Flow Series)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFilter Element\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40µm (Standard Filtration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBowl Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Pint (0.5 Liter) with Liquid Level Indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDrain Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiaphragm Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelieving (Allows excess pressure to escape)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAdjustment Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 psig (0 to 4 bar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGauge Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (N)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFunctional Components\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Bowl\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-capacity transparent or guarded bowl configuration.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eN \/ N\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Yoke\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnit is supplied without the mounting yoke (required for installation).\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKnob\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-rising adjustment knob for pressure setting.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eL\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-to-medium pressure control, optimized up to 4 bar.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eYoke Requirement\u003c\/strong\u003e: This specific model (NN) is supplied without a yoke. To install it into a pneumatic line, you must have an Olympian Plus B68 series yoke of the appropriate port size (e.g., 3\/4\" or 1\" NPT\/ISO G).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Direction\u003c\/strong\u003e: Ensure the unit is installed with the air flowing in the direction of the arrow cast into the body.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Orientation\u003c\/strong\u003e: The unit must be mounted vertically with the bowl at the bottom to ensure the filter element and manual drain function correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelieving Feature\u003c\/strong\u003e: Since this is a \"Relieving\" model, the outlet pressure can be reduced even when the system is dead-ended. You will hear a brief hiss of air from the adjustment knob when lowering the pressure; this is normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBowl Clearance\u003c\/strong\u003e: Leave sufficient space (approx. 150mm) below the bowl to allow for manual draining and element replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQs)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace the manual drain with an automatic one?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Norgren offers auto-drain conversion kits for the B68 series. This is recommended for systems where high moisture accumulation is expected and manual maintenance is difficult.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the \"Relieving\" diaphragm?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt allows the regulator to vent downstream pressure when you turn the knob to a lower setting. This is a safety and convenience feature that prevents high pressure from being \"trapped\" in the downstream line.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if I use this without a gauge?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"N\" code indicates no gauge is included. While the unit will function perfectly, it is highly recommended to install a gauge into one of the 1\/8\" or 1\/4\" ports on the body to ensure accurate pressure settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 40µm element sufficient for sensitive tools?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e40µm is standard for general industrial air tools. However, for precision instruments or paint spraying, you may require a secondary 5µm filter or an oil-removal (coalescing) filter downstream.\u003c\/p\u003e","brand":"Norgren","offers":[{"title":"Default Title","offer_id":53077931196779,"sku":"B68G-NNK-MR3-RLN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/b68g-nnk-mr3-rln-v3dbgbgabwf.jpg?v=1775733454"}],"url":"https:\/\/www.plcprotech.com\/collections\/norgren.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}