{"title":"Prosoft","description":"\u003cp\u003eProSoft Technology specializes in communication solutions that bridge disparate industrial networks. The architecture features protocol gateways, wireless modules, and in-chassis modules for major PLC platforms like Allen-Bradley and Schneider. Technical characteristics include support for over 40 protocols (Modbus, PROFIBUS, EtherNet\/IP) and ruggedized hardware for harsh field conditions. Functionally, ProSoft modules enable seamless data exchange between different brands of automation hardware, ensuring plant-wide connectivity. By providing the \"missing link\" in industrial networking, ProSoft ensures that legacy systems and modern controllers can work together to optimize operational visibility and data acquisition.\u003c\/p\u003e","products":[{"product_id":"plx32-eip-mbtcp-prosoft-ethernet-ip-to-modbus-tcp-ip-gateway","title":"PLX32-EIP-MBTCP ProSoft EtherNet\/IP to Modbus TCP\/IP Gateway","description":"\u003ch3\u003eIndustry Application \u0026amp; Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX32-EIP-MBTCP (PLX32EIPMBTCP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance standalone gateway designed to provide seamless bidirectional data exchange between EtherNet\/IP based controllers and Modbus TCP\/IP networks. In complex industrial landscapes such as petrochemical refineries, automated wastewater treatment facilities, and smart manufacturing plants, this gateway acts as a critical protocol translator. By allowing Allen-Bradley Logix processors to communicate directly with Modbus TCP\/IP field devices (such as power meters, VFDs, and flow computers), the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX32-EIP-MBTCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the need for expensive high-level middleware. Its robust architecture supports high-speed I\/O connections, ensuring that time-critical process variables are updated with minimal latency, which is essential for reducing system downtime and maintaining precise operational control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX32-EIP-MBTCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a dual-port design that enables physical separation of the EtherNet\/IP and Modbus TCP\/IP networks if required, enhancing network security and reducing broadcast traffic interference.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEtherNet\/IP Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 2 Class 1 I\/O connections for real-time control and 5 Class 3 Server connections for messaging. It is fully compatible with legacy PLC-5 and SLC systems via PCCC, as well as modern ControlLogix\/CompactLogix systems via CIP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModbus TCP\/IP Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe gateway functions as both a Client and a Server. The Client mode supports up to 160 configurable commands, while the Server mode supports up to 10 concurrent connections (5 MBAP and 5 Encapsulated), providing extensive flexibility for multi-device polling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Mapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal memory allows for large-scale data mapping between the two protocols, with support for \"Write-only-on-data-change\" to optimize network bandwidth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLX32-EIP-MBTCP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal (10 to 36 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC @ 300 mA (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Connection Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e248 Bytes Input \/ 248 Bytes Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax RPI Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 ms per connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModbus Function Codes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1, 2, 3, 4, 5, 6, 15, 16, 22, 23\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations \u0026amp; Maintenance FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this gateway support older SLC 500 or PLC-5 processors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The PLX32-EIP-MBTCP supports PCCC messaging, which allows legacy Allen-Bradley controllers to exchange data with modern Modbus TCP\/IP devices without upgrading the entire control platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many Modbus devices can I connect to a single gateway?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe gateway supports up to 10 Modbus TCP\/IP Servers (Slaves) in Client mode and can handle up to 160 fully configurable commands, making it suitable for high-density instrument clusters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat diagnostic tools are available for troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe gateway provides individual error codes for every Modbus command. These can be mapped back to the PLC memory, allowing operators to see exactly which field device has failed directly on their HMI screen.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor high-speed applications, utilize the Class 1 I\/O connection (Implicit Messaging) rather than Class 3 (Explicit Messaging). Set the Requested Packet Interval (RPI) to no less than 5 ms to ensure stable data throughput without overloading the gateway processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe PLX32-EIP-MBTCP is rated for an extended temperature range of -25 to 70 deg C. For installations in chemical or high-humidity environments, ensure the gateway is housed in a NEMA 4 or IP66 rated enclosure to protect against corrosive atmospheric elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways use a regulated 24 VDC industrial power supply. Given the module's 15 G operational shock rating, ensure DIN-rail clips are fully engaged and use end-anchors to prevent lateral movement in high-vibration environments such as mining crushers or stamping presses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256522603,"sku":"PLX32-EIP-MBTCP","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/plx32-eip-mbtcp-jyvshfpamxp.png?v=1775727292"},{"product_id":"prosoft-mvi56e-mnetc-controllogix-modbus-tcp-ip-enhanced-module","title":"ProSoft MVI56E-MNETC ControlLogix Modbus TCP\/IP Enhanced Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNETC (MVI56EMNETC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as an advanced Modbus TCP\/IP multi-client and server interface, engineered specifically for the Rockwell Automation ControlLogix platform. In mission-critical sectors such as oil refining, thermal power plants, and subsea mining, the module provides a high-speed data conduit between the processor and distributed Modbus TCP\/IP devices. Unlike standard modules, the \"Enhanced\" series offers improved backplane speed and a larger internal database, enabling the integration of hundreds of smart field instruments without compromising scan times. By delivering real-time diagnostics and support for multiple simultaneous connections, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reduces system troubleshooting time and eliminates communication bottlenecks that lead to costly production outages.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Model Variations\u003c\/h3\u003e\n\u003cp\u003eThe MVI56E series is designed with modularity to address different environmental stressors. Understanding the model suffix is critical for ensuring long-term hardware reliability in the field.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard (MVI56E-MNETC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for controlled industrial environments. It operates within a standard temperature range and features standard circuit board protection for general-purpose applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Temperature (MVI56E-MNETCXT):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for unconditioned cabinets or extreme geographic locations. This version extends the operating range from -25 to 70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"XT\" variant includes a factory-applied conformal coating. This protective layer shields the internal electronics from moisture, chemical corrosion, and conductive dust, which is essential for saltwater environments or chemical processing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMVI56E-MNETC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP (Client and Server)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 mA @ 5 VDC \/ 3 mA @ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp (Standard)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp (XT Version)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED Indicators (APP, OK) \/ Web Page Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCritical Technical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many Modbus Client connections can the MVI56E-MNETC support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" in the model name stands for Client. This module is enhanced to support up to 30 simultaneous Client connections, allowing it to aggregate data from a vast network of remote I\/O, drives, and power meters concurrently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the MVI56E-MNETC compatible with older ControlLogix L6 processors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module maintains downward compatibility with L6 series processors and older versions of RSLogix 5000, as well as the modern Studio 5000 environment. It fits into any standard 1756 ControlLogix chassis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the 'Enhanced' (E) series over legacy MVI56 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Enhanced series supports \"Discovery Service,\" allowing the ProSoft Configuration Builder software to find the module on the network without knowing its IP address. It also features a scrolling LED display for real-time status and error codes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical \u0026amp; Corrosive Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor installations located in wastewater treatment or heavy chemical plants, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNETCXT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be specified. The conformal coating is vital to prevent \"silver migration\" and corrosion on the PCB traces caused by hydrogen sulfide (H2S) or high salinity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure maximum cybersecurity and deterministic performance, always use a managed industrial switch. Segregate the Modbus TCP\/IP traffic from the corporate IT network using VLANs to prevent broadcast storms from impacting the ControlLogix backplane performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen operating at the upper limit of the temperature range (60 deg C or 70 deg C for XT), ensure that the chassis power supply is not overloaded. High current draw on the 5 VDC backplane rail generates significant heat; maintain a minimum of 5 cm clearance around the chassis for adequate airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256555371,"sku":"MVI56E-MNETC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/mvi56e-mnetc-1v5rsrtaspl.png?v=1775727273"},{"product_id":"prosoft-plx31-eip-ascii4-ethernet-ip-to-ascii-four-port-gateway","title":"ProSoft PLX31-EIP-ASCII4 EtherNet\/IP to ASCII Four-Port Gateway","description":"\u003ch3\u003eSystem Integration Capability\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX31-EIP-ASCII4 (PLX31EIPASCII4)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands as a high-performance industrial gateway designed to bridge the gap between modern EtherNet\/IP networks and legacy serial ASCII devices. In high-demand environments such as automotive assembly lines, automated pharmaceutical packaging, and food processing plants, this gateway facilitates the seamless integration of barcode scanners, weigh scales, and RFID readers directly into the Logix control architecture. By providing four independent serial ports, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX31-EIP-ASCII4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the need for multiple single-port converters, reducing cabinet footprint and simplifying network topology. Its ability to handle high-speed I\/O connections with a 5 ms RPI ensures that mission-critical data reaches the PLC without latency, effectively preventing production bottlenecks and minimizing unscheduled downtime.\u003c\/p\u003e\n\u003ch3\u003eProtocol Architecture \u0026amp; Communications\u003c\/h3\u003e\n\u003cp\u003eThe gateway utilizes a dual-stack architecture to ensure maximum compatibility across the Rockwell Automation ecosystem. It supports both Explicit Messaging (Class 3) for asynchronous data exchange and Implicit Messaging (Class 1) for real-time control.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Processor Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNative integration for ControlLogix, CompactLogix, and legacy platforms including SLC 500 and PLC-5 using PCCC or CIP messaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEtherNet\/IP Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 4 Class 1 I\/O connections with substantial data payload capacities (248 bytes input\/output), ensuring complex ASCII strings are transmitted in a single scan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuad-Port Serial Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the four ports operates independently, allowing for mixed baud rates and framing parameters across different serial instruments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Portability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures an integrated web server for remote diagnostics and a dedicated SD card slot for configuration backup, enabling rapid \"disaster recovery\" module replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLX31-EIP-ASCII4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 RS-232 \/ RS-422 \/ RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (10 to 36 VDC range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 mA @ 24 VDC (610 mA max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 80 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration \/ Shock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 G @ 150 Hz \/ 15 G Operational\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (cm)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.67 x 5.05 x 11.13 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations \u0026amp; Maintenance FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the PLX31-EIP-ASCII4 communicate with multiple PLCs simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The gateway supports up to 5 Class 3 Server connections, allowing multiple controllers to query the gateway or a single controller to manage different serial ports via distinct messaging paths.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a serial device is replaced with a different baud rate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach of the 4 ports is individually configurable via the ProSoft Configuration Builder (PCB) software. You can update the baud rate (up to 115.2K) for a specific port without affecting the communication stability of the other three ports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module suitable for outdoor or unconditioned cabinets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith an extended operating temperature range of -25 to 70 deg C, the module is specifically engineered for harsh industrial environments that experience significant thermal cycling, provided the relative humidity remains non-condensing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe PLX31-EIP-ASCII4 is built for extreme reliability. It carries IEC 60068-2-27 shock ratings (15G operational) and IEC 60068-2-6 vibration ratings (5G), making it ideal for mounting on machinery that experiences high physical stress or near heavy rotating equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower \u0026amp; Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways utilize the GND terminal provided on the power connector. In environments with high electromagnetic interference (EMI), ensure that the serial cable shields are grounded at a single point to prevent ground loops while protecting the sensitive RS-232\/485 signals from noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRPI Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the gateway supports a 5 ms Requested Packet Interval (RPI), engineers should balance the RPI setting against the actual baud rate of the serial devices. Setting an RPI significantly faster than the serial transmission speed offers no data benefit and increases unnecessary network overhead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256588139,"sku":"PLX31-EIP-ASCII4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PLX31-EIP-ASCII4-mn2voq52svf.jpg?v=1775727282"},{"product_id":"prosoft-mvi56-mcmr-modbus-reduced-data-block-communication-module","title":"ProSoft MVI56-MCMR Modbus Reduced Data Block Communication Module","description":"\u003ch3\u003eIndustry Application \u0026amp; Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56-MCMR (MVI56MCMR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Modbus Master\/Slave communication module designed specifically for ControlLogix platforms requiring optimized backplane data transfer. In complex industrial environments such as offshore oil platforms, automated power substations, and mineral processing facilities, backplane bandwidth is a premium resource. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56-MCMR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaddresses this by utilizing a \"Reduced Data Block\" structure, which allows the module to operate effectively in remote I\/O racks over ControlNet or EtherNet\/IP where large I\/O connections might otherwise fail or cause latency. By ensuring consistent data throughput between Modbus serial devices and the Allen-Bradley processor, this module prevents communication bottlenecks and safeguards critical process uptime.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture \u0026amp; Protocol Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56-MCMR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures two independent serial ports, capable of running different Modbus commands or baud rates simultaneously. Its internal database maps directly to the ControlLogix processor memory, supporting up to 5000 words of data.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Transfer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"MCMR\" designation signifies its ability to interface with the CPU using smaller I\/O blocks (typically 40, 60, or 120 words), making it the standard choice for remote rack installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully supports Modbus RTU and ASCII modes. It provides native handling for floating-point data, essential for flow meters and power analyzers, with specific support for Enron and Daniel implementations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Port Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBoth ports operate independently as either a Master or a Slave, allowing the module to act as a data concentrator between legacy field instruments and modern SCADA systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMVI56-MCMR\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 mA @ 5 VDC; 3 mA @ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModbus Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTU (Binary) and ASCII\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 to 115,200 baud\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShock \/ Vibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 g (Operational) \/ 5 g @ 10 to 150 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEssential Maintenance FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary advantage of the MCMR version over the standard MVI56-MCM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MCMR version is designed for remote chassis applications. Standard modules often require large I\/O scheduled tags that exceed the capacity of remote bridge links. The MCMR uses smaller, manageable data blocks to ensure stable communication over network bridges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle high-precision flow meter data?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides built-in floating-point support. You can configure the module to swap bytes or words to match the requirements of specific instruments like Daniel or Enron flow computers without writing complex ladder logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check if the 'ERR' LED is flashing red?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis typically indicates a configuration mismatch or a communication timeout on one of the ports. Verify that the baud rate, parity, and slave IDs in the configuration file exactly match the field devices.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProfessional Installation \u0026amp; Deployment Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemote Rack Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56-MCMR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein a remote chassis, ensure the ControlNet or EtherNet\/IP adapter is configured to support the specific block size defined in the module’s configuration. Mismatched block sizes will result in an I\/O Configuration Error in RSLogix 5000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Port Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor RS-485 multi-drop networks in high-vibration mining or heavy industrial areas, utilize high-quality shielded twisted-pair cable. Always terminate the last node of the network with a 120-ohm resistor to prevent signal reflections that cause intermittent data loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCFG Port Usage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe RJ45 configuration port is RS-232 only. Always use the ProSoft-supplied cable for diagnostics. Do not connect a standard Ethernet cable to this port, as it may cause electrical damage to the communication UART.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256620907,"sku":"MVI56-MCMR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/mvi56-mcmr-wrggkylvdgs.jpg?v=1775727258"},{"product_id":"plx32-eip-mbtcp-prosoft-technology-ethernet-ip-to-modbus-tcp-ip-gateway","title":"PLX32-EIP-MBTCP ProSoft Technology EtherNet\/IP to Modbus TCP\/IP Gateway","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview and Protocol Bridging Utility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX32-EIP-MBTCP (PLX32EIPMBTCP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial gateway designed to facilitate seamless data exchange between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetworks. Engineered by ProSoft Technology for the Allen-Bradley ecosystem, this module serves as a critical bridge for integrating diverse plant-floor devices—such as power meters, drives, and flow computers—directly into Logix-based control systems. The gateway features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual independent Ethernet ports\u003c\/strong\u003e, allowing each protocol to reside on isolated subnets. This architectural advantage eliminates the need for complex NAT routing or changing device IP addresses, maintaining strict network security and organization while reducing commissioning overhead in large-scale infrastructure projects.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Architecture and Data Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX32-EIP-MBTCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for high-capacity data handling, supporting an internal database of up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10,000 16-bit registers\u003c\/strong\u003e. This allows for the aggregation of massive datasets from multiple Modbus devices into a single EtherNet\/IP interface.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Protocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with a wide array of legacy and modern Allen-Bradley controllers, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix (CLX)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix (CMPLX)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSLC\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroLogix\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Port Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo physically separate Ethernet ports enable secure data passing between subnets (e.g., a dedicated Modbus device network and a corporate\/PLC network).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisaster Recovery:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSD card slot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for the storage of configuration files. In the event of hardware failure, the module can be replaced and reconfigured instantly by swapping the card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes an embedded\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEDS Add-On Profile (AOP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Studio 5000, allowing for drag-and-drop integration and automated tag generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePLX32-EIP-MBTCP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProSoft Technology (Allen-Bradley Partner)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e (Class 1 and Class 3)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol B\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e (Client\/Server)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Database\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000 16-bit Registers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e Nominal (10 to 36 VDC Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.13 cm x 5.05 cm x 13.67 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Mbps Auto-sensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple I\/O connections for RPI prioritization\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e6.0 kg\u003c\/strong\u003e (Ruggedized industrial packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eIntegrated Technical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"Data Prioritization\" feature improve system performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX32-EIP-MBTCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for multiple I\/O connections to the PLC. By assigning different\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRequested Packet Intervals (RPI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto specific datasets, engineers can prioritize high-speed control data (low RPI) while allowing non-critical status data to update less frequently, optimizing network bandwidth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to secure the module against unauthorized configuration changes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. For modules with firmware version 1.04 or greater, a physical\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodule switch\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be used to lock the configuration, preventing remote changes via the web interface or configuration software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Allen-Bradley message types are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe gateway supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePCCC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for legacy SLC and PLC5 communication) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCIP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for modern Logix-based messaging), ensuring full backward compatibility across the entire Allen-Bradley product line.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Protocols\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSubnet Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the dual-port feature, ensure that Port 1 and Port 2 are assigned to different IP subnets (e.g., 192.168.1.x and 10.0.0.x). Connecting both ports to the same physical switch on the same subnet can cause broadcast storms or loop-back errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEarthing and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGND terminal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the 3-position power connector. In high-noise environments near Variable Frequency Drives (VFDs), ensure the DIN rail is properly bonded to the central plant ground to protect the 16-bit register integrity from EMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit is rated for operation up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e70 Celsius\u003c\/strong\u003e. However, for maximum lifespan, ensure at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance above and below the module to facilitate natural convection cooling within the enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX32-EIP-MBTCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow instruction cycle time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand high connection capacity (supporting up to 5 Class 3 Server connections). Its ability to act as both a Modbus Client (Master) and Server (Slave) simultaneously provides unparalleled flexibility. Whether you are migrating legacy Modbus RTU systems (via TCP converters) or connecting new smart instrumentation to a ControlLogix rack, the ProSoft PLX32 series provides a \"set-and-forget\" solution that withstands the rigors of extreme industrial temperatures and vibration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53076256653675,"sku":"PLX-32-EIP-MBTCP","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/plx-32-eip-mbtcp-ybtu3ovgmeu.jpg?v=1775727280"},{"product_id":"mvi56-mnet-prosoft-modbus-tcp-ip-communication-module","title":"MVI56-MNET ProSoft Modbus TCP\/IP Communication Module","description":"\u003ch3\u003eModule Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56-MNET (MVI56MNET)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical bridge between Rockwell Automation ControlLogix backplanes and Schneider Electric or other Modbus TCP\/IP compatible networks. Designed for high-reliability environments such as oil refineries, power generation plants, and large-scale mining operations, this interface module allows a ControlLogix processor to easily interface with Modbus TCP\/IP servers and clients. By facilitating seamless bidirectional data transfer, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56-MNET\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eminimizes integration complexity and significantly reduces potential system downtime by providing real-time diagnostics and robust network stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56-MNET\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a single-slot backplane component, drawing power directly from the ControlLogix rack. Its architecture supports both Client (Master) and Server (Slave) modes simultaneously, allowing the module to initiate commands to remote devices while responding to requests from a central SCADA or HMI system.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull implementation of the Modbus TCP\/IP protocol, utilizing the standard Port 502.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 5,000 words of internal database memory for large-scale data mapping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a standard 10\/100 Base-T RJ45 Ethernet port for high-speed industrial communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Interaction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed data transfer via Block Transfer or Side-Connect technology ensures minimal latency between the module and the CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMVI56-MNET\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP Interface Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 mA @ 5 VDC \/ 3 mA @ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 g @ 10 Hz to 150 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperational Shock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommon Technical Inquiries\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the MVI56-MNET support multiple client connections simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the module is designed to operate as a Server, supporting multiple concurrent Client connections. This allows various devices, such as HMIs and redundant PLCs, to access data from the module at the same time without performance degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in a remote I\/O chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the MVI56-MNET must be installed in the local ControlLogix chassis containing the CPU or connected via a high-speed bridge. It relies on specific backplane communication that is generally not supported in standard remote I\/O configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between MVI56-MNET and MVI56E-MNET?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"E\" in the newer version stands for Enhanced. While the standard MVI56-MNET is a robust legacy solution, the Enhanced version includes additional features like a web server for diagnostics and a simplified configuration via the Ethernet port rather than the console port.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the ControlLogix chassis is mounted vertically to allow for natural convection. In high-density racks where the ambient temperature exceeds 50 deg C, maintain a 1-slot gap between the MVI56-MNET and high-heat-producing modules (like high-voltage AC output cards) to prevent localized overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse Category 5e or better shielded twisted-pair (STP) cabling for all Ethernet runs. Ensure the RJ45 shield is properly bonded to the industrial-grade switch to mitigate electromagnetic interference (EMI) in high-vibration and electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Consistency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore commissioning, verify that the module's firmware version is compatible with the version of RSLogix 5000 or Studio 5000 being utilized. Using the latest Add-On Profile (AOP) will significantly streamline the integration and I\/O mapping process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256686443,"sku":"MVI56-MNET","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/mvi56-mnet-whvvmy4d3tx.jpg?v=1775727258"},{"product_id":"prosoft-rlx2-ihnf-w-a-industrial-wireless-hotspot-ip67-fcc-model","title":"ProSoft RLX2-IHNF-W-A Industrial Wireless Hotspot IP67 FCC Model","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRLX2-IHNF-W-A (RLX2IHNFWA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a hardened industrial wireless hotspot developed by ProSoft for outdoor automation networks. The unit delivers 802.11 a b g n wireless connectivity inside an IP67 weatherproof enclosure designed for harsh industrial environments. Engineers deploy this hotspot in oil terminals, mining conveyors, water treatment facilities, and remote substations where wired Ethernet installation is impractical. The die cast aluminum housing resists vibration, dust, and moisture while supporting pole mounting. Three external N type antenna ports allow directional or sector antenna configuration. The device operates across extended temperature ranges and maintains reliable wireless communication for mobile equipment, SCADA connectivity, and distributed control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture\u003c\/h3\u003e\n\u003cp\u003eThe RLX2-IHNF-W-A uses an industrial grade wireless radio supporting 2.4 GHz band communication. The design includes three N connector antenna interfaces for diversity and extended coverage deployment. The sealed enclosure meets IP67 protection requirements and supports outdoor pole mounting. Internal surge protection protects the radio from lightning induced transients. The device accepts wide range 10 to 24 VDC external power and integrates industrial temperature rated components. FCC compliant radio output ensures stable communication in regulated installations. The unit supports high speed wireless bridging for PLC, RTU, and remote I O communication.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRLX2-IHNF-W-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless Standard\u003c\/td\u003e\n\u003ctd\u003e802.11 a b g n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Band\u003c\/td\u003e\n\u003ctd\u003e2.412 GHz to 2.462 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1 to 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAntenna Ports\u003c\/td\u003e\n\u003ctd\u003e3 N type connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eDie cast aluminum IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePole mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 75 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 100 percent RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e230 x 160 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs RLX2-IHNF-W-A suitable for outdoor installations?\u003c\/strong\u003e\u003cbr\u003eYes. The IP67 die cast aluminum enclosure protects against water, dust, and harsh weather environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit connect to PLC or SCADA networks?\u003c\/strong\u003e\u003cbr\u003eYes. The device provides wireless Ethernet connectivity for PLC, RTU, SCADA, and remote I O communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat antenna types can be used with this hotspot?\u003c\/strong\u003e\u003cbr\u003eThe unit supports external N connector antennas including omni directional, sector, and directional panel antennas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the device support wide temperature operation?\u003c\/strong\u003e\u003cbr\u003eYes. The hotspot operates from -40 to 75 deg C for outdoor industrial installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Installation Guide\u003c\/h3\u003e\n\u003cp\u003eMount the unit on a grounded metal pole using the integrated mounting bracket. Ensure the enclosure remains vertical to maintain antenna radiation pattern. Avoid mounting near large metal structures that block RF coverage.\u003c\/p\u003e\n\u003cp\u003eUse outdoor rated coaxial cable between antenna and device. Keep cable length as short as possible to reduce signal loss. Tighten N connectors using proper torque to prevent moisture ingress.\u003c\/p\u003e\n\u003cp\u003eSupply regulated 10 to 24 VDC power using shielded industrial cable. Connect earth ground to the enclosure grounding point to improve surge protection in lightning prone areas.\u003c\/p\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256719211,"sku":"RLX2-IHNF-W-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/rlx2-ihnf-w-a-hbgets0xgwq.png?v=1775727295"},{"product_id":"mvi69-mcm-prosoft-modbus-master-slave-network-interface-module","title":"MVI69-MCM ProSoft Modbus Master\/Slave Network Interface Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe MVI69-MCM acts as a powerful communication bridge, allowing Rockwell Automation CompactLogix processors to interface seamlessly with Modbus-compliant devices. This module functions as a \"gateway\" in the 1769 backplane, enabling the PLC to act as either a Modbus Master or a Modbus Slave. By integrating this module, engineers can easily pull data from or send commands to power meters, VFDs, solar inverters, and varied RTU equipment. The MVI69-MCM excels in distributed control environments where serial communication is required across long distances, providing a cost-effective alternative to replacing legacy serial hardware with Ethernet-based equivalents.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003eDual-Port Versatility\u003c\/h3\u003e\n\u003cp\u003eThe module features two independent serial application ports (P1 and P2). Each port operates autonomously, meaning you can configure Port 1 as a Modbus Master to poll field instruments while simultaneously configuring Port 2 as a Modbus Slave to provide data to a third-party SCADA system or HMI.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe MVI69-MCM appears to the CompactLogix processor as a standard I\/O module. It utilizes efficient block transfers to move up to 5000 registers of Modbus data between the module’s internal database and the PLC’s controller tags, ensuring high-speed data refreshes without taxing the CPU’s communication overhead.\u003c\/p\u003e\n\u003ch3\u003eOptical Isolation and Ruggedness\u003c\/h3\u003e\n\u003cp\u003eTo protect the CompactLogix rack from industrial electrical noise and ground loops, both application ports feature 500V optical isolation from the backplane. This hardware-level protection ensures that a surge on a long RS-485 field wire run will not damage the expensive PLC processor or other modules in the chassis.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 mA max @ 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDistance Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 slots (L43\/L45 installations require first 2 slots)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Application (P1, P2) + 1 Configuration (CFG)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Standards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232, RS-422, and RS-485 (Jumper Selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V Optical Isolation (Backplane to Communications)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0° C to 60° C (32° F to 140° F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU and Modbus ASCII\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 5000 16-bit registers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation and Maintenance Guide\u003c\/h2\u003e\n\u003ch3\u003ePower Supply Distance Rating\u003c\/h3\u003e\n\u003cp\u003eThe MVI69-MCM has a distance rating of 2. This means the module must be installed within two slots of the CompactLogix power supply. For high-performance L43 and L45 controllers, always place this module in the first two available slots of the 1769 bus to ensure sufficient current for the 800mA load.\u003c\/p\u003e\n\u003ch3\u003eJumper Configuration for RS-485\u003c\/h3\u003e\n\u003cp\u003eBefore sliding the module into the rack, set the physical jumpers located on the side of the PCB to match your communication standard. For RS-485 (2-wire) daisy-chain networks, ensure the termination jumpers are engaged if the module is at the end of the physical cable run to prevent signal reflection.\u003c\/p\u003e\n\u003ch3\u003eDiagnostics via CFG Port\u003c\/h3\u003e\n\u003cp\u003eUtilize the RJ45-to-DB9 configuration cable to connect to the \"CFG\" port. Use ProSoft Configuration Builder (PCB) software to monitor real-time port statistics. This port is strictly RS-232 and provides a \"window\" into the Modbus traffic, allowing you to identify CRC errors or timeout issues without interrupting the main PLC application.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe MVI69-MCM is a field-proven solution for extending the life of serial-based infrastructure. Its ability to support up to 100 commands per port allows for the management of high-density instrument clusters. Because the module handles the Modbus protocol stack internally, the PLC logic remains clean—engineers only need to interact with simple Data Tags rather than writing complex serial bit-bashing code. This \"offloading\" of protocol management ensures consistent scan times even as your network of field devices grows.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use Port 1 for RS-232 and Port 2 for RS-485 at the same time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes. Both ports are fully independent. You can mix and match physical layers and baud rates for each port as long as the internal jumpers are set correctly for each individual channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the purpose of the \"Battery\" LED indicator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The Battery LED monitors the health of the internal lithium battery used to maintain the module’s configuration and data database during power cycles. If this LED turns red, replace the battery promptly to avoid data loss during a power outage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module support the Modbus TCP\/IP protocol?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No. The MVI69-MCM is strictly a serial (RTU\/ASCII) module. For Modbus TCP\/IP communication over Ethernet, you would require the MVI69-MNET module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How do I handle 4-wire RS-422 communication with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Set the port jumpers to the RS-422 position. The supplied RJ45-to-DB9 adapter provides the necessary pins for TX+, TX-, RX+, and RX- signals. Ensure your shielding is grounded at only one end to prevent ground loops.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256751979,"sku":"MVI69-MCM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/mvi69-mcm-zmibi5eiukv.jpg?v=1775727275"},{"product_id":"prosoft-plx31-mbtcp-mbs-modbus-tcp-ip-to-serial-gateway","title":"ProSoft PLX31-MBTCP-MBS | Modbus TCP\/IP to Serial Gateway","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft PLX31-MBTCP-MBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial gateway designed for seamless communication between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus Serial (RTU\/ASCII)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetworks. It allows a Modbus TCP\/IP Client to control Modbus Serial devices, or vice versa, acting as a bridge between Ethernet-based systems and legacy serial infrastructure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLX31-MBTCP-MBS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP to Modbus Serial Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (10 to 36 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC @ 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C (-13°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eEthernet (Modbus TCP\/IP) Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Clients\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Servers (MBAP)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Servers (Encapsulated)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommand List\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 160 fully configurable Client commands\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eSerial (Modbus Master\/Slave) Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRS Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232, RS-422, and RS-485 (Hardware selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 baud to 115.2 kbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eParity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone, Even, Odd\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 or 8 bits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNode Address\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 to 247 (Software selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommand List\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 100 commands per Master port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRTS On\/Off Delay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 65535 milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003ePhysical Characteristics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eData\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.05 cm x 11.13 cm x 13.67 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Wiring\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eThe unit requires a 24 VDC power source. Ensure the polarity is correct when wiring the terminal block to avoid damaging the internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Port Selection\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eThe serial port is versatile (RS-232\/422\/485). Ensure the jumpers or software settings match your physical wiring. For\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elong-distance runs, ensure proper 120-ohm termination is applied at the end of the line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Configuration\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUse the ProSoft Configuration Builder (PCB) software to set the IP address. Ensure the gateway is on the same subnet as your Modbus TCP\/IP Master (Client).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eThe unit is designed for standard DIN-rail mounting. Ensure adequate clearance for airflow, especially in high-temperature environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQs)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this gateway support both Modbus RTU and Modbus ASCII?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The serial port can be configured for either RTU or ASCII messaging, depending on your field device requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the difference between MBAP and Encapsulated servers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMBAP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Modbus Application Protocol) is the standard header used over TCP\/IP (Port 502).\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEncapsulated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModbus refers to standard serial packets wrapped in a TCP\/IP envelope, often used by legacy software drivers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How many serial devices can I connect to one PLX31-MBTCP-MBS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emode, you can connect up to 32 devices (standard load) to the serial port, provided they all use the same baud rate and parity settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the configuration stored if power is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The configuration is stored in non-volatile memory and is automatically reloaded upon power-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What diagnostic tools are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit features front-panel LEDs for Power, Ethernet Link\/Activity, and Serial Transmit\/Receive status. Additionally, the ProSoft Configuration Builder provides a \"Diagnostic\" window for real-time traffic monitoring.\u003c\/p\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256784747,"sku":"PLX31-MBTCP-MBS","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/plx31-mbtcp-mbs-emclefn0gqo.jpg?v=1775727286"}],"url":"https:\/\/www.plcprotech.com\/collections\/prosoft.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}