{"title":"Sensors","description":"\u003cp\u003eEnhance plant efficiency, dynamic process control, and predictive maintenance with our comprehensive inventory of industrial automation sensors from leading global brands like Siemens, \u003ca href=\"\/collections\/honeywell\"\u003eHoneywell\u003c\/a\u003e, \u003ca href=\"\/collections\/bently-nevada\"\u003eBently Nevada\u003c\/a\u003e, and \u003ca href=\"\/collections\/epro\"\u003eEPRO\u003c\/a\u003e. From\u003ca href=\"\/collections\/siemens\"\u003e Siemens\u003c\/a\u003e SITRANS magnetic flow meters and acoustic sensors to Honeywell combustible gas detectors and UV flame sensors, alongside precision vibration and displacement probes, our high-performance solutions provide reliable real-time monitoring across complex harsh-environment processing systems.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-330180-90-cn-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-90-CN 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN \u003c\/strong\u003eis a high-grade eddy-current displacement transmitter engineered by Bently Nevada for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evibration monitoring platform. Functioning as the core electronic conditioning driver in a non-contacting transducer circuit, this module converts high-frequency radio frequency fluctuations into a linear voltage output proportional to target movement. Heavy-duty rotating machinery infrastructures—including thermal power generation plants, petrochemical refineries, and continuous mining mills—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto track fluid-film bearing dynamic health. By providing direct backward compatibility for obsolete legacy instrumentation, this sensor monitors shaft vibration and thrust positions accurately. This allows engineering teams to detect structural misalignment early, prevent devastating machine trips, and eliminate unprogrammed production downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe mechanical mounting, total loop tuning, and country-specific safety certifications for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity sensor are systematically categorized through its specific alphanumeric suffix options.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180 Baseline Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the fundamental hardware platform for the high-stability 3300 XL Proximitor Sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-90 System Length Parameter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishes a total calibrated loop system length of 9.0 meters (29.5 feet) configuration optimized exclusively for flat surface panel mounting. The internal oscillator circuit matches the specific impedance profile of a combined 9.0-meter probe and extension cable without field calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-CN Special Approval Token:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates regional country-specific hazardous area certification compliance, satisfying specialized industrial safety standards for deployment across localized high-risk automated areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications \u0026amp; Structural Limits\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMachinery Telemetry Metric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIndustrial Sensor Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-90-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes Business Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Transducer Measurement Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Interfacing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccepts 3300-series 5 mm, 3300 8 mm, and 3300 XL 8 mm Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Block Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremium Grade A308 Die-Cast Aluminum Enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal System Tuning\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 meters (29.5 feet) Shared Loop Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Mounting Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlat Surface Panel Mount Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Output Scale\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) Linear Scaling Vector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Operational Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC Negative Potential Power Supply Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Equipment Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.246 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +100 deg C Extended Ambient Range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +105 deg C Maximum Structural Limits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Compatibility \u0026amp; Diagnostics FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat legacy hardware components does the 330180-90-CN replace within active control racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 330180-90-CN serves as the advanced direct technological upgrade for obsolete legacy components, fully replacing old \u003cstrong\u003e330100-90-02\u003c\/strong\u003e and 330100-90-05 models. It allows seamless drop-in modernization without requiring users to replace existing compatible field probes, preserving infrastructure investments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this specific Proximitor model be supplied with validated manufacturing trace documentation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because this industrial transducer is manufactured in the United States, an official Certificate of Origin (COO) can be integrated into the technical documentation package upon project request, satisfying quality management system tracing and international import parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field probe variations can be connected to the input terminals of this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor contains an adaptive input stage that accommodates a variety of Bently Nevada non-contacting sensors. It operates reliably with traditional 3300-series 5 mm, standard 3300-series 8 mm, or advanced 3300 XL 8 mm proximity probes and matching extension cables arranged in a 9.0-meter total loop configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connector Isolation and Moisture Safeguards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen connecting the proximity probe to the extension cable, shield the coaxial junction completely using high-dielectric silicone sleeve insulation. If the coaxial metal shells touch the machine frame, they will establish secondary ground paths that cause signal distortion. Wrap the completed junction in self-vulcanizing tape to prevent moisture or oil ingress from destabilizing the RF sensor data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Gap Voltage Target Selection and Verification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSet the physical position of the probe tip by tracking the DC gap voltage at the Proximitor terminal points using a calibrated multimeter. Adjust the probe depth inside the machine case until the voltage reads exactly -10.0 VDC, which positions the target directly in the center of the sensor's linear scaling range. Tighten the probe locknut carefully to prevent any shifting during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Paths and Noise Isolation Routing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the power supply lines and signal output loops away from high-voltage motor conductors using twisted, shielded instrumentation cables. Connect the cable shield to the main ground at the machinery monitoring rack terminal block only, cutting the shield clean at the sensor end. This practice prevents ground loop currents from injecting noise into the vibration processing cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515521899,"sku":"330180-90-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-90-cn-proximitor-sensor-w254xy3equw_73962b30-817f-4e70-9998-c31a1f0328f9.jpg?v=1765440079"},{"product_id":"bently-nevada-330180-92-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-92-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-92-05\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a high-precision, eddy-current displacement conditioning device developed by Bently Nevada for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Health Monitoring series. Acting as the core signal processing module within a non-contacting proximity probe circuit, this hardware converts raw radio-frequency (RF) field variations into linear voltage metrics directly proportional to shaft position. Mission-critical industrial assets—including large-scale steam turbine generators in power plants, high-pressure centrifugal compressors in oil refineries, and heavy-duty grinding mills in mining processing sites—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-92-05 (330180-92-05)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto track dynamic fluid-film bearing clearance. By delivering stable, sub-micron vibration and thrust readings directly to a 3500 rack system, this sensor detects structural oil whip or shaft misalignment early. This eliminates unexpected catastrophic machine trips, protects high-cost rotating shafts, and reduces factory unprogrammed downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe exact hardware configuration, total system loop calibration, and hazardous location approval profile of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-92-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity sensor can be systematically decoded through its alphanumeric suffix structure.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180 Product Root:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the fundamental hardware classification for the high-performance 3300 XL Proximitor Sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-92 System Length Option:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDictates a total calibrated loop system length of 9.0 meters (29.5 feet). This parameter ensures the internal oscillator matches the impedance of a 9.0-meter combined probe and extension cable kit without requiring local field recalibration. This option specifically specifies a panel-mount chassis with no specialized DIN-rail mounting hardware included.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05 Multi-Agency Approval Option:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertifies that the module meets strict international hazardous area explosion-proof standards, carrying full, simultaneous CSA, ATEX, and IECEx safety certifications for installation in Zone 0, Zone 1, and Zone 2 explosive environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Standards \u0026amp; Dimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMachinery Protection Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIndustrial Sensor Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-92-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes Business Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Proximity Transducer Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Interfacing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccepts 3300-series 5 mm, 3300 8 mm, and 3300 XL 8 mm Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Structural Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremium Grade A308 Cast Aluminum Shell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Scale Calibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 meters (Total shared probe and cable length)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Scale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) Nominal Linear Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mA to 12 mA Nominal Current Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC Negative Supply Input via Monitor Rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.246 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +100 deg C Extended Ambient Range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +105 deg C Structural Storage Envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Maintenance \u0026amp; Operational FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this 9.0-meter Proximitor sensor operate with a standard 5.0-meter extension cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The internal oscillation matrix of the 330180-92-05 is specifically tuned to match the capacitive and inductive characteristics of a 9.0-meter system. Mixing this module with a 5.0-meter probe and cable kit shifts the resonant frequency, which alters the scale factor from the standard 7.87 V\/mm (200 mV\/mil) and results in incorrect vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific field benefits does the A308 cast aluminum enclosure material provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe premium A308 cast aluminum housing acts as a durable shield that blocks high-frequency electromagnetic interference (EMI) and radio-frequency noise from affecting the internal circuitry. It also provides excellent physical protection against mechanical impacts, atmospheric corrosion, and moisture ingress in harsh compressor deck environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does an electrical technician identify a probe short-circuit versus an open-circuit fault during runtime?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBy measuring the DC gap voltage at the sensor terminal block, field technicians can quickly check system integrity. A reading of 0 VDC or a very low positive value indicates a short-circuit condition, typically caused by a crimped cable trace or a grounded terminal connection. Conversely, a reading that matches the full supply voltage (-24 VDC) indicates an open-circuit fault, pointing to a broken terminal line or a severed probe tip.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connector Insulation and Structural Moisture Guarding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen joining the probe lead to the extension cable inside the machine bracket, the coaxial connection must be completely isolated from the machine frame using high-dielectric silicone sleeves. Moisture or dirt inside this connection can degrade the RF signal, causing immediate measurement drift. Wrap the completed junction in self-fusing vulcanizing tape to keep out moisture on open compressor decks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Alignment and Calibration Benchmarks:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring installation, set the physical probe gap using a digital multimeter connected across the sensor's \"OUT\" and \"COM\" terminal terminals. Rotate the probe body until the DC voltage measures exactly -10.0 VDC, which corresponds to the precise mid-point center of the sensor's linear calibration range. Tighten the probe locknut to the recommended installation torque specification to prevent mechanical drift during high-vibration turbine operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Board Wiring Layout and Noise Isolation Protocols:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the -24 VDC power and signal output loops through high-integrity twisted, shielded instrumentation cables. Ground the cable shields at a single point only, typically at the 3500 monitor rack terminal block, and cut the field shield clean at the sensor end. This grounding technique prevents ground-loop current paths from introducing electrical noise into the vibration monitoring channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515620203,"sku":"330180-92-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-92-05-proximitor-sensor-2qdeihaxoud_6675da58-f3f4-4717-a992-7d62ce7a6bbd.jpg?v=1765440080"},{"product_id":"bently-nevada-330180-91-00-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-91-00 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-91-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e configured for a 9.0 m system length, featuring a 35 mm DIN rail mounting plate, and supplied with no agency approvals. This sensor operates by conditioning and driving the signal from an eddy-current proximity probe, translating physical shaft displacement into a proportional DC voltage signal for monitoring system inputs.\u003c\/p\u003e\n\n\u003cp\u003eThis variant differs from the panel-mount configurations (such as Option 90) by utilizing a DIN-mount base that occupies a narrower 35.1 mm slot, allowing for high-density mounting in protective enclosures. While other configurations include hazardous area approvals (such as Option 05), this configuration (Option 00) is for general-purpose environments where agency listings are not required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 91 specifies a 9.0-meter electrical system length matched to 3300 XL 8 mm probes and extension cables.\u003c\/li\u003e\n  \u003cli\u003eDIN-rail mounting base provides electrical isolation from the mounting surface.\u003c\/li\u003e\n  \u003cli\u003eOption 00 specifies a configuration without hazardous area agency approvals.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass or gold-plated beryllium copper connectors provide secure signal paths.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal strips facilitate field wiring without screw-clamping mechanisms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration measurement on steam and gas turbines, compressors, motors, and pumps.\u003c\/li\u003e\n  \u003cli\u003eAxial position monitoring of rotating shafts in industrial machinery.\u003c\/li\u003e\n  \u003cli\u003eNon-contacting eddy-current displacement monitoring in industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330180-91-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, 9.0 m system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption A - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e91\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption B - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required (No agency approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-91-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (Not required)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one non-contacting 3300 XL 8 mm Proximity Probe and Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Housing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA308 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 35.1 mm x 89.4 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.246 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eWiring Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003ePower Supply input (-24 Vdc nominal)\u003c\/td\u003e\n      \u003ctd\u003eAccepts 0.2 to 1.5 mm2 (16 to 24 AWG) conductor sizes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eSystem Common (Return path)\u003c\/td\u003e\n      \u003ctd\u003eAccepts 0.2 to 1.5 mm2 (16 to 24 AWG) conductor sizes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eProportional voltage output signal\u003c\/td\u003e\n      \u003ctd\u003eAccepts 0.2 to 1.5 mm2 (16 to 24 AWG) conductor sizes\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the module onto a standard 35 mm DIN rail. Ensure there is a minimum clearance of 3.05 mm above the device to allow easy removal from the DIN rail.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use a 3-conductor shielded triad cable for connecting the sensor output to the monitoring system. Keep the maximum cable run length below 305 meters (1,000 feet).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Strips:\u003c\/strong\u003e Utilize the SpringLoc terminal strips for fast, secure connections without screw-tightening. Stripped wire leads insert directly into the terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e The integral mounting pad provides absolute electrical isolation from the DIN rail. No additional external isolator plates are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility (EMC):\u003c\/strong\u003e Complies with European Union Directive 2014\/30\/EU standards including EN 61000-6-2 and EN 61000-6-4.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestriction of Hazardous Substances (RoHS):\u003c\/strong\u003e Complies with Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e Certified to SIL 2 (HFT = 0) and SIL 3 (HFT = 1) limits when used within a qualified safety instrumented system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approval:\u003c\/strong\u003e None (Option 00 is specified for general-purpose, non-hazardous areas).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518897003,"sku":"330180-91-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-91-00-5-8-mm-proximitor-sensor-rcdw0doug3q_b421d6f1-53db-40f9-9769-1c1febddd9f7.jpg?v=1765440123"},{"product_id":"bently-nevada-330180-90-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-90-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 90 (9.0 meters system length, panel mount) and Option 05 (CSA, ATEX, IECEx approvals) specify this 3300 XL Proximitor Sensor configuration — \u003cstrong\u003e330180-90-05\u003c\/strong\u003e. This non-contacting sensor is a core conditioning module for Bently Nevada 3300 XL proximity transducer systems, which are used to measure radial shaft vibration, axial thrust position, and speed on rotating industrial machinery. The unit houses specialized oscillator and demodulator circuitry that generates a radio frequency signal, drives the connected eddy-current probe, and conditions the returning signal into a continuous analog voltage proportional to the dynamic gap distance.\u003c\/p\u003e\n\n\u003cp\u003eThis panel-mount variant features a standardized 4-hole mounting plate that shares an identical footprint with older Proximitor designs, simplifying legacy upgrades. The aluminum mounting base provides built-in electrical isolation, removing the requirement for separate isolator plates. Calibrated for 9.0-meter systems, the 330180-90-05 requires precise matching with a 3300 XL 8 mm proximity probe and extension cable that sum to a total physical length of exactly 9.0 meters. Option 05 compliance adds certified protection for hazardous locations, enabling safe deployment under global intrinsic safety and non-sparking\/non-incendive standards.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 90 configuration specifies a 9.0-meter system length calibration matched for 4-hole panel mounting.\u003c\/li\u003e\n  \u003cli\u003eOption 05 agency approval delivers certified safety for hazardous locations under CSA, ATEX, and IECEx approvals.\u003c\/li\u003e\n  \u003cli\u003eStandardized panel-mount footprint provides backwards compatibility with legacy Bently Nevada Proximitor sensors.\u003c\/li\u003e\n  \u003cli\u003eIntegrated electrical isolation on the mounting base eliminates the need for separate isolator hardware.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal block connectors provide secure field wiring connections without requiring special installation tools.\u003c\/li\u003e\n  \u003cli\u003eAdvanced RF\/EMI immunity satisfies European CE standards without requiring specialized shielded conduit or metallic enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and dynamic positioning measurements on high-speed turbines, compressors, and pumps.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position and shaft eccentricity monitoring in power generation and petrochemical applications.\u003c\/li\u003e\n  \u003cli\u003eContinuous speed and tachometer input conditioning on industrial motors, generators, and fans.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection monitoring loops connected to Bently Nevada 3500 Series racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330180-90-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, 9.0 m system length, panel mount, hazardous area approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption A - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, panel mount configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption B - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals (Intrinsically Safe \u0026amp; Non-Incendive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-90-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePanel mount (4-hole footprint)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (nominal -24 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Signal Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog negative voltage (-1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), from 0.25 mm to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-6.5%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Field Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 meters (1000 feet) of 3-conductor shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 61.0 mm x 50.8 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e246 g (0.246 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon reference \/ system ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog voltage output signal (-1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the Proximitor sensor on a clean, flat surface using the integrated panel-mount base; the mounting base provides integral electrical isolation directly.\u003c\/li\u003e\n  \u003cli\u003eUse tinned 3-conductor shielded triad field wiring cable with wire sizes ranging from 0.2 mm2 to 1.5 mm2 (16 AWG to 24 AWG).\u003c\/li\u003e\n  \u003cli\u003eInsert wires directly into the SpringLoc terminal strip; no special insertion or clamping tools are required.\u003c\/li\u003e\n  \u003cli\u003eLimit total field wiring between the Proximitor sensor and the monitoring system to a maximum of 305 meters (1000 feet) to prevent high-frequency signal roll-off.\u003c\/li\u003e\n  \u003cli\u003eEnsure that probe and extension cables maintain a minimum bend radius of 25.4 mm (1.0 inch) during routing.\u003c\/li\u003e\n  \u003cli\u003eFor hazardous locations, follow the certified wiring diagrams for intrinsically safe or non-incendive\/non-sparking requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Immunity for Industrial Environments), EN 61000-6-4 (Emissions for Industrial Environments)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e CE mark, RoHS Directive 2011\/65\/EU, China RoHS compliance (EFUP 15 years)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (Hardware Fault Tolerance HFT = 0), SIL 3 capable in redundant (HFT = 1) systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 05):\u003c\/strong\u003e CSA, ATEX, and IECEx certifications for intrinsically safe (ia) and non-incendive\/non-sparking (nA, ec) installations in Class I, Division 1\/2 and Zone 0\/2 hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519060843,"sku":"330180-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-90-05-3300xl-5-8-mm-proximitor-sensor-fiezfwww3ne_ce9ec8c7-1922-48ed-8e3a-ab4d790e2b9b.jpg?v=1765440127"},{"product_id":"bently-nevada-330180-51-00-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-51-00 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-51-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e configuration featuring a 5.0-meter system length compatibility and an integrated DIN-rail mounting base. This specific variant is specified with the 00 option code, indicating that it does not carry hazardous area agency approvals. The device houses the high-frequency oscillator and demodulator circuitry necessary to condition raw displacement data from a compatible 3300 XL 8 mm proximity probe and extension cable. It converts the physical gap between the probe tip and the target material into a continuous, linear analog voltage output proportional to shaft movement.\u003c\/p\u003e\n\u003cp\u003eBy pairing the sensor with a 5.0-meter total system length probe and extension cable, the measurement system maintains its linear calibration across a full 2.0 mm (80 mils) dynamic range. The integrated mounting base of this variant provides built-in electrical isolation, preventing ground loops and eliminating the need for separate isolator plates. The spring-loaded terminal strips provide secure field-wiring connections without requiring manual screw-type clamping.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 51 specifies compatibility with a 5.0-meter total system length and incorporates a 35 mm DIN-rail mount.\u003c\/li\u003e\n\u003cli\u003eOption 00 designates a standard build where special hazardous area certifications are not required.\u003c\/li\u003e\n\u003cli\u003eIntegrated SpringLoc terminal strips facilitate field-wiring installations without specialized tooling.\u003c\/li\u003e\n\u003cli\u003eIsolating mounting base prevents electromagnetic interference and ground-loop noise.\u003c\/li\u003e\n\u003cli\u003eBroad compatibility with standard 3300 XL 8 mm proximity probes and extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis Proximitor sensor is used for machinery vibration, position, and shaft keyphasor measurements in standard industrial environments. Typical installations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam, gas, and hydro turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating process compressors\u003c\/li\u003e\n\u003cli\u003eHigh-speed industrial pumps and gearboxes\u003c\/li\u003e\n\u003cli\u003eLarge electric motors and generator shaft bearings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-51-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor, 5.0 meters, DIN-rail mount, standard approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Total Length \u0026amp; Mounting Option\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet) system length, DIN-rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number \/ SKU\u003c\/td\u003e\n\u003ctd\u003e330180-51-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail mount (Option 51)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capability\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300-series 5 mm or 3300 XL 8 mm proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Sensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) over linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), starting approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc; 12 mA maximum current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohms nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Strip Support\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wiring Distance\u003c\/td\u003e\n\u003ctd\u003e305 meters (1000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e89.4 mm x 81.3 mm x 61.0 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Label\u003c\/th\u003e\n\u003cth\u003eConnection Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eAnalog displacement signal output to monitoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSystem common \/ signal ground reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT\u003c\/td\u003e\n\u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the mounting base is locked onto a standard 35 mm DIN rail. Provide a minimum of 3.05 mm (0.120 inches) of vertical clearance above the housing to facilitate standard removal from the rail. Use three-conductor shielded triad cables for field wiring to connect terminals to the monitor. Keep field wiring within the maximum distance limit of 305 meters (1000 feet) to prevent output signal attenuation.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Standard\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003ctd\u003eComplies with European electromagnetic compatibility (EMC) standards without special shielded conduit or housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519781739,"sku":"330180-51-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-51-00-3300-xl-proximitor-sensor-proximity-switch-24ni1ysosth_23365f6d-1973-456e-ab2a-a90ed88b27f2.jpg?v=1765440141"},{"product_id":"bently-nevada-330180-91-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-91-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330180-91-05\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e configured for a 9.0 meter total system length with DIN mount capability and CSA, ATEX, and IECEx hazardous area approvals. This sensor acts as the signal conditioning interface between the 3300 XL 8 mm proximity probe and the monitoring system, converting the eddy-current displacement signal into a voltage output proportional to the distance between the probe tip and the observed conductive surface.\u003c\/p\u003e\n\n\u003cp\u003eThis unit is specifically designed for 3300 XL 8 mm proximity transducer systems, ensuring total system length (probe plus extension cable) matches the 9.0 meter calibration. The DIN mount configuration (Option 91) allows for standard industrial rail installation, while the hazardous area approval (Option 05) supports deployment in environments requiring CSA, ATEX, and IECEx compliance.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTotal System Length: 9.0 meters (29.5 feet) for 3300 XL 8 mm transducer chains\u003c\/li\u003e\n\u003cli\u003eMounting Style: DIN rail mount configuration\u003c\/li\u003e\n\u003cli\u003eAgency Approvals: CSA, ATEX, and IECEx for hazardous area installations\u003c\/li\u003e\n\u003cli\u003eSensor Interface: Compatible with standard 3300 XL 8 mm proximity probes and extension cables\u003c\/li\u003e\n\u003cli\u003eSignal Conditioning: Industry-standard 200 mV\/mil output with enhanced RFI\/EMI immunity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine and compressor shaft vibration monitoring\u003c\/li\u003e\n\u003cli\u003eRotor axial position measurement\u003c\/li\u003e\n\u003cli\u003eCritical rotating machinery protection\u003c\/li\u003e\n\u003cli\u003eHazardous environment machinery control (requires certified 05-option hardware)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330180-91-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Total Length and Mounting\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003ctd\u003e9.0 meters (29.5 feet) system length, DIN mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330180-91-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eLess than 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the total length of the 3300 XL probe and extension cable equals the 9.0 meter calibration of this Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003eMount in a protected environment, such as a Bently Nevada approved housing, to prevent direct exposure to process fluids or harsh weather.\u003c\/li\u003e\n\u003cli\u003eEnsure the DIN rail is securely grounded to minimize electrical noise.\u003c\/li\u003e\n\u003cli\u003eMaintain proper segregation between signal wiring and high-voltage AC lines to prevent EMI interference.\u003c\/li\u003e\n\u003cli\u003eCheck terminal connections for tightness and ensure wire shielding is correctly terminated at the ground point.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA: Certified for hazardous locations\u003c\/li\u003e\n\u003cli\u003eATEX: Certified for hazardous locations\u003c\/li\u003e\n\u003cli\u003eIECEx: Certified for hazardous locations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520240491,"sku":"330180-91-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-91-05-proximitor-sensor-0bvonuk0bnc_3a87ef59-2989-4a0f-940c-3006c22c31b0.jpg?v=1765440148"},{"product_id":"bently-nevada-330180-085-03-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-085-03-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 085 (8.5 meters length), Option 03 (armored cable with connector protector), and Option 05 (CSA\/ATEX\/IECEx approvals) specify this 3300 XL \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e configuration — \u003cstrong\u003e330180-085-03-05\u003c\/strong\u003e. This sensor module functions as a signal conditioner, driving the eddy-current proximity probe and translating the high-frequency transducer signal into a proportional displacement voltage. The analog voltage output represents the exact gap change between the probe tip and the observed shaft target area, transmitting directly into machinery protection monitors.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e330180-085-03-05\u003c\/strong\u003e configuration is specifically calibrated for an 8.5 m total electrical system length (Option 085) and supports armored extension cabling assemblies paired with integrated fluorosilicone connector protectors (Option 03). Designed for installation in environments demanding rigorous intrinsic safety and non-sparking certifications, it includes comprehensive international approvals (Option 05) such as ATEX, IECEx, and CSA. The module incorporates electrical isolation in its base, removing the necessity of separate insulator plates and facilitating direct DIN rail or panel mounting.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8.5 Meter Calibrated Length (Option 085):\u003c\/strong\u003e Generates matching impedance parameters calibrated to an 8.5 m proximity probe and cable configuration, preventing impedance mismatch errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling Armor Integration (Option 03):\u003c\/strong\u003e Formulated to seamlessly match armored extension cables with integrated connector protectors to shield delicate connections from fluids and particulates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals (Option 05):\u003c\/strong\u003e Holds CSA, ATEX, and IECEx approvals for safe utilization in hazardous industrial locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRFI\/EMI Noise Immunity:\u003c\/strong\u003e Suppresses electrical noise from surrounding radios and variable frequency drives, complying with European CE requirements without requiring specialized metallic conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpringLoc Terminals:\u003c\/strong\u003e Uses spring-clamp connections that eliminate screws and prevent the connection degradation typically caused by machine vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and dynamic profiling on steam and gas turbines\u003c\/li\u003e\n\u003cli\u003eAxial position and thrust offset measurement on centrifugal compressor shafts\u003c\/li\u003e\n\u003cli\u003eRotor casing expansion and eccentricity monitoring in power generation installations\u003c\/li\u003e\n\u003cli\u003eBearing clearance and structural vibration tracking on high-power industrial motors and pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-085-03-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, armored compatibility\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Calibrated Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e085\u003c\/td\u003e\n      \u003ctd\u003e8.5 meters (27.9 feet) system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Cabling and Protection Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eArmored cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-085-03-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCalibrated Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.5 meters (27.9 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog proportional voltage (typically -10 VDC to -24 VDC range or 7.87 V\/mm [200 mV\/mil])\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRequired Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-24 VDC nominal supply (typically -18 VDC to -26 VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpringLoc terminal strips (accepts up to 1.5 mm2 \/ 16 AWG wire)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePanel mount or 35 mm DIN rail compatible configurations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81 mm x 61 mm x 51 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the industrial terminal block is wired with shielded, twisted-pair cabling to shield the dynamic analog displacement signal from electrical noise.\u003c\/li\u003e\n\u003cli\u003eSecurely clamp the housing onto a standard 35 mm DIN rail or bolt directly to a panel. The integrated base isolation eliminates the need for separate non-conductive isolator plates.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends in any connected probe or extension cabling, maintaining a bend radius above 25.4 mm (1.0 inch) to prevent physical cable damage or signal degradation.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring by inserting a flat-blade screwdriver to release the spring-clamp inside the terminal, sliding in the stripped wire, and releasing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Approved for hazardous zone applications as intrinsically safe (Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc) or non-sparking (Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified for Class I, Division 1, Groups A, B, C, and D hazardous environments when paired with intrinsically safe barriers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with standard European RFI\/EMI directives without requiring high-cost metallic conduit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525417835,"sku":"330180-085-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-085-03-05-proximity-probe-housing-assemblies-vp0dr22uf4n_f1685e23-303f-46ea-b271-e47a4108d19f.jpg?v=1765440264"},{"product_id":"bently-nevada-330180-x1-00-mod-145004-128-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-00 MOD:145004-128 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-X1-00 MOD:145004-128\u003c\/strong\u003e is a 3300 XL Proximitor Sensor configured to support specialized machinery monitoring requirements. This unit acts as the signal conditioning interface in a \u003cstrong\u003e3300 XL 8 mm proximity transducer system\u003c\/strong\u003e, converting the eddy-current probe signal into a linear 4 to 20 mA proportional output for critical vibration and axial position monitoring applications. The sensor is designed for high-precision, non-contact measurement of rotor shaft displacement, providing critical diagnostic data for rotating machinery such as turbines, compressors, and large motors.\u003c\/p\u003e\n\u003cp\u003eThe Proximitor sensor is optimized for use within the 3300 XL series monitoring chains, ensuring electrical and physical compatibility with standard 3300 XL probes and extension cables. This configuration includes specific modifications (MOD:145004) to meet unique installation or operational criteria. The system delivers a stable 200 mV\/mil scale factor and is engineered to maintain signal integrity over field wiring distances up to 305 meters.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for 3300 XL 8 mm proximity transducer systems\u003c\/li\u003e\n\u003cli\u003eProvides linear output for vibration and position measurement\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 XL probes and extension cables\u003c\/li\u003e\n\u003cli\u003eSupports field wiring distances up to 305 meters\u003c\/li\u003e\n\u003cli\u003eEngineered for harsh industrial environments and critical machinery protection\u003c\/li\u003e\n\u003cli\u003eStandard 200 mV\/mil scale factor for consistent data output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration and axial position monitoring on large rotating machinery\u003c\/li\u003e\n\u003cli\u003eTurbine, compressor, and generator shaft displacement sensing\u003c\/li\u003e\n\u003cli\u003eCritical machinery protection for fluid-film bearing equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial environments requiring long-distance signal transmission\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-00 MOD:145004-128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to +80 degC (Hazardous area dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials\u003c\/td\u003e\n\u003ctd\u003eA380 Aluminum housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx certified (refer to documentation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the total system length (Probe + Extension Cable + Proximitor) matches the calibrated Proximitor sensor length for accurate measurement.\u003c\/li\u003e\n\u003cli\u003eMount the Proximitor sensor in a protected, dry location, ideally using the Bently Nevada DIN-mount or panel-mount hardware.\u003c\/li\u003e\n\u003cli\u003eUse 3-conductor shielded twisted-pair cable for field wiring to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum cable bend radius of 25.4 mm (1.0 in) to prevent coaxial cable damage.\u003c\/li\u003e\n\u003cli\u003eEnsure the probe gap is set to the recommended voltage (typically -9 Vdc) for radial vibration monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFunctional Safety: SIL 2 (HFT=0) \/ SIL 3 (HFT=1)\u003c\/li\u003e\n\u003cli\u003eEMC Directive: 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eRoHS Directive: 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eHazardous Area: Class I, Zone 0, 1, 2 (Approvals vary by region)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525778283,"sku":"330180-X1-00 MOD: 145004-128","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-00-mod-145004-128-proximitor-sensor-k3lxcnmnkbv_51d0b447-f415-41a8-a30d-df126424dfd2.jpg?v=1765440270"},{"product_id":"bently-nevada-330180-x1-05mod-145193-01-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05MOD:145193-01 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-X1-05MOD:145193-01\u003c\/strong\u003e: This 3300 XL Proximitor Sensor is configured with Option X1 for DIN-rail mounting, Option 05 for multiple hazardous area agency approvals, and is custom-calibrated under modification 145193-01 for non-standard target materials.\u003c\/p\u003e\n\u003cp\u003eIn contrast to standard 330180 variants calibrated for AISI 4140 steel, this Proximitor sensor includes factory recalibration circuitry to maintain precise eddy-current measurement linearity on specific non-standard alloys. It integrates oscillator and detection electronics to condition proximity probe signals into a continuous displacement output, directly compatible with machinery protection monitors such as the Bently Nevada 3500 system.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-rail mount form factor specified by option X1 for secure electrical enclosure mounting\u003c\/li\u003e\n\u003cli\u003eMultiple hazardous area approvals under option 05 including ATEX, IECEx, and CSA intrinsic safety standards\u003c\/li\u003e\n\u003cli\u003eCustom target material calibration under Bently Nevada engineering modification MOD 145193-01\u003c\/li\u003e\n\u003cli\u003eConverts eddy-current RF signals into a continuous voltage output proportional to target distance\u003c\/li\u003e\n\u003cli\u003eSeamlessly integrates with 3300 XL 5mm\/8mm 9m proximity probes and extension cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and axial position monitoring on high-speed industrial machinery\u003c\/li\u003e\n\u003cli\u003eHeavy industrial applications in power generation, oil and gas, petrochemical, and chemical processing\u003c\/li\u003e\n\u003cli\u003eSpecialized rotor dynamic analysis on turbomachinery utilizing non-standard shaft materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145193-01\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5mm\/8mm Proximitor Sensor, 9-Meter System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length and Mounting\u003c\/td\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eModification, DIN Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals (CSA, ATEX, IECEx intrinsically safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModification Number\u003c\/td\u003e\n\u003ctd\u003eMOD:145193\u003c\/td\u003e\n\u003ctd\u003eTarget material recalibration modification family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial Option\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eOption 01 under custom modification 145193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145193-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5mm\/8mm 9m proximity probe and extension cable systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mount (Option X1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) linear analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e10 to 90 mils (0.25 to 2.30 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -24 Vdc input power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.3 mm x 61.2 mm x 103.1 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon \/ Circuit ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eOutput displacement signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVTG (PROX)\u003c\/td\u003e\n\u003ctd\u003ePower supply (-24 Vdc input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoaxial Connector\u003c\/td\u003e\n\u003ctd\u003eConnects to 3300 XL extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount securely on a standard 35 mm DIN rail in an environmentally protected enclosure.\u003c\/li\u003e\n\u003cli\u003eEnsure proper electrical isolation and shield grounding to prevent interference from external noise.\u003c\/li\u003e\n\u003cli\u003eConnect coaxial cable from the extension cable to the Proximitor coaxial connector, ensuring it is finger-tight.\u003c\/li\u003e\n\u003cli\u003eMaintain an appropriate probe-to-target gap matching the linear range of 10 to 90 mils.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\/IECEx Intrinsically Safe (Option 05)\u003c\/li\u003e\n\u003cli\u003eCSA Class I, Division 1, Groups A, B, C, D (Option 05)\u003c\/li\u003e\n\u003cli\u003eCE Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528006507,"sku":"330180-X1-05 MOD: 145193-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145193-01-3300-xl-proximitor-sensor-5w11ezz4jnd_f4825ce2-814e-4ef2-a538-253f1ab12228.jpg?v=1765440307"},{"product_id":"bently-nevada-330180-x1-cn-mod-143416-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-CN MOD:143416-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003e330180-X1-CN MOD:143416-05\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis \u003cmark\u003ea high-precision Eddy Current Proximitor Sensor belonging to the\u003cspan\u003e \u003c\/span\u003e3300 XL\u003cspan\u003e \u003c\/span\u003e8 mm Proximity Transducer System\u003c\/mark\u003e.\u003cspan\u003e \u003c\/span\u003eThis specific unit handles both static displacement (position) and dynamic displacement (vibration) measurements on critical rotating machinery components. The device translates the distance between an 8 mm probe tip and the observed conductive target surface into a proportional analog voltage signal. The\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003econfiguration specifies a 35 mm DIN rail mount layout, while the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eCN\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esuffix denotes localized safety compliance, including ATEX\/IECEx and Chinese NEPSI hazardous area approvals. The structural designation\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003erepresents a factory-calibrated modification engineered to provide enhanced electrical durability and target profile optimization inside heavy industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ctable class=\"NRefec\" width=\"628\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"cZCYO firstRow\"\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eParameter\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003e330180\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eOrdering Code Extension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eX1-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eModification Reference Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eProximitor Proximity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\n\u003cspan class=\"Yjhzub\"\u003e3300 XL\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 mm Transducer Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eMounting Hardware Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e35 mm Standard DIN Rail Mount (\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eHazardous Area Approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eATEX, IECEx, NEPSI Chinese Markings (\u003cspan class=\"Yjhzub\"\u003eCN\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eSensor Operating Principle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eEddy Current Loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eFrequency Response Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0 to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eNominal Target Diameter Integration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e8 mm Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eSystem Output Signal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eContinuous Analog AC\/DC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Net Width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e12.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Net Height\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Net Depth \/ Thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e2.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eBecause Bently Nevada transducer components feature internal matching circuits calibrated to exact system loop lengths, procurement must specify both the core part configurations and factory modification tags.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nordwel.com\/bently-nevada-330180-x1-cn-mod-143416-05-proximitor-sensor_p16754.html\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eComponent Part Number:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e330180-X1-CN\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eFactory Modification Suffix:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eSystem Family Code:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e3300 XL\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Series\u003c\/span\u003e\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nordwel.com\/bently-nevada-330180-x1-cn-mod-143416-05-proximitor-sensor_p16754.html\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Configuration \u0026amp; Engineering Guide\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ch4\u003eTotal Loop Length Verification\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e330180\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esensor must be paired with an 8 mm probe and extension cable matching the precise overall electrical system length (typically 5.0 meters or 9.0 meters total). Mismatching a 5-meter proximitor module with a 9-meter cable array shifts the eddy current oscillation baseline, resulting in severe scale factor errors, zero-point drift, and inaccurate machine vibration readings.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eRFI Immunity and Enclosure Grounding\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e3300 XL\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esensor design features advanced radio frequency interference (RFI) shielding, satisfying European CE mark parameters without requiring special steel conduits. However, the physical DIN rail mounting strip (\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e) must have a direct low-impedance electrical bond to the instrument enclosure ground rail. Avoid mounting the Proximitor board immediately adjacent to high-power variable frequency drive (VFD) output cables or contactor blocks.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nexinstrument.com\/330180-x1-cn-mod-143416-34.html\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eField Coaxial Connector Protection\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe coaxial links connecting the field probe lead to the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emodule are highly sensitive to moisture, grease, and mechanical stress. Use specialized connector silicone sleeves during assembly to insulate the raw coaxial threads. Ensure the extension cable minimum bend radius of 25.4 mm (1.0 inch) is strictly observed within the cabinet wire trays to prevent micro-cracks in the inner shield layers.\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the MOD:143416-05 suffix designate?\u003c\/strong\u003e\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003edesignation identifies a factory-engineered modification applied directly to the internal tuning parameters of the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e330180\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eseries. This often dictates a altered calibration profile to accommodate non-standard shaft target materials, customized signal gains, or specialty protective coatings on the outer housing block.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nordwel.com\/bently-nevada-330180-x1-cn-mod-143416-05-proximitor-sensor_p16754.html\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"wJwe6c\"\u003e\u003cspan class=\"IjM6od\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this sensor hot-swappable while the TSI monitoring rack is online?\u003c\/strong\u003e\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the Proximitor sensor can be replaced while the primary monitoring rack (such as a Bently Nevada 3500 rack) remains powered up. However, disconnecting the sensor will immediately open the loop circuit, driving the corresponding rack channel into an \"Unstable\/Fault\" state. Bypass or inhibit any automated trip relays before swapping the hardware to avoid accidental machinery shutdown.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the X1 and CN tags signify in the ordering configuration?\u003c\/strong\u003e\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003econfiguration ensures the Proximitor sensor housing comes fitted with an integrated structural foot designed for standard DIN rail clip mounting. The\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eCN\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003edesignation indicates that the product adheres to specific regional requirements for China, carrying the NEPSI hazardous area explosion-proof stamps along with ATEX\/IECEx data.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666533445995,"sku":"330180-X1-CN MOD:143416-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-cn-mod-143416-05-proximity-interface-module-ir4xttrnbna_19ca2830-6c66-4cb4-aed3-2151e21bb306.jpg?v=1765440387"},{"product_id":"bently-nevada-330180-x1-05-mod-145004-82-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05 MOD:145004-82 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330180-X1-05MOD:145004-82\u003c\/strong\u003e serves as the signal conditioning interface for the 3300 XL 8 mm Proximity Transducer System. This \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e receives the radio frequency signal from the proximity probe, processes the eddy-current data, and generates a proportional voltage output suitable for connection to monitoring and protection instrumentation.\u003c\/p\u003e\n\n\u003cp\u003eThe unit configuration includes specific factory-verified modifications (MOD:145004) to meet established system requirements. This Proximitor sensor is designed for use in 3300 XL monitoring chains, maintaining linear signal output and compatibility with standard Bently Nevada 8 mm transducer components. The electronics are contained within a protected housing designed for panel or DIN rail mounting in industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated 3300 XL technology for signal conditioning of eddy-current proximity signals\u003c\/li\u003e\n\u003cli\u003eVoltage output proportional to probe gap, suitable for vibration and position monitoring\u003c\/li\u003e\n\u003cli\u003eOption 05 Agency Approval package (CSA, ATEX, IECEx)\u003c\/li\u003e\n\u003cli\u003eMOD:145004 factory-specified modification for custom operational requirements\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 XL 8 mm probe and extension cable systems\u003c\/li\u003e\n\u003cli\u003eDesigned for continuous operation in harsh industrial conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft vibration and axial position measurement\u003c\/li\u003e\n\u003cli\u003eCritical rotating machinery protection\u003c\/li\u003e\n\u003cli\u003eTurbine, compressor, and pump shaft monitoring\u003c\/li\u003e\n\u003cli\u003eFluid film bearing health assessment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145004-82\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption - X1\u003c\/td\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eCustom Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption - 05\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eAgency Approval (CSA, ATEX, IECEx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption - MOD\u003c\/td\u003e\n\u003ctd\u003eMOD:145004\u003c\/td\u003e\n\u003ctd\u003eFactory Modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption - 82\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003ctd\u003eSystem Length\/Matching Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145004-82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +100 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +105 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eA380 Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Probes and Extension Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the Proximitor sensor is mounted in a protected, dry area, typically within a localized instrumentation housing or control cabinet. Maintain proper grounding practices by connecting the sensor common to the system ground. Verify the cable connection integrity between the probe, extension cable, and Proximitor sensor to prevent signal attenuation. When installing in hazardous areas, ensure the local installation meets the requirements defined by the agency approval (Option 05).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666536067435,"sku":"330180-X1-05 MOD：145004-82","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145004-82-proximitor-sensor-bkydnqpgzrl_152f019b-bc78-4e84-a3fd-6c0ca1983955.jpg?v=1765440416"},{"product_id":"bently-nevada-330180-x1-05-mod-145004-63-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05 MOD:145004-63 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330180-X1-05 MOD:145004-63\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e designed for integration with 3300 XL 8 mm proximity transducer systems. This component acts as the signal conditioning interface between the proximity probe and the monitoring system, providing a proportional voltage output corresponding to the distance between the probe tip and the observed conductive surface.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration, identified by the MOD:145004-63 suffix, includes factory-applied modifications tailored for specialized application requirements within machinery protection chains. It maintains compatibility with standard Bently Nevada 3300 XL components, including extension cables and 8 mm probes, ensuring consistent eddy-current displacement measurement performance for critical rotating assets such as turbines, compressors, and pumps.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 3300 XL 8 mm proximity transducer system architectures\u003c\/li\u003e\n\u003cli\u003eVoltage output proportional to shaft vibration and axial position\u003c\/li\u003e\n\u003cli\u003eAdvanced signal processing for RFI\/EMI immunity\u003c\/li\u003e\n\u003cli\u003eDIN rail or panel mounting configurations (refer to specific system installation drawings)\u003c\/li\u003e\n\u003cli\u003eOption 05: CSA, ATEX, and IECEx hazardous area certifications\u003c\/li\u003e\n\u003cli\u003eFactory modified configuration (MOD:145004-63)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration monitoring on centrifugal compressors\u003c\/li\u003e\n\u003cli\u003eAxial position (thrust) measurement on steam and gas turbines\u003c\/li\u003e\n\u003cli\u003eRotor speed and phase reference measurements\u003c\/li\u003e\n\u003cli\u003eGeneral rotating machinery protection in hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145004-63\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Total Length\/Mounting\u003c\/td\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eModified Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModification\u003c\/td\u003e\n\u003ctd\u003eMOD:145004-63\u003c\/td\u003e\n\u003ctd\u003eFactory Modified Part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx (Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe Proximitor sensor must be installed in a protected environment, such as a Bently Nevada approved housing, to prevent exposure to moisture and corrosive agents. When routing signal cables, maintain separation from high-voltage AC lines to minimize electromagnetic interference. Ensure that the total system length (probe + extension cable) matches the calibrated length for this Proximitor sensor.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666539409771,"sku":"330180-X1-05 MOD:145004-63","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145004-63-proximitor-sensor-0h3jxf3l53a_bba42002-65f4-4aec-99bf-2246f40d3ed4.jpg?v=1765440450"},{"product_id":"bently-nevada-330850-91-00-3300-xl-25-mm-proximitor-sensor","title":"Bently Nevada 330850-91-00 3300 XL 25 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330850-91-00\u003c\/strong\u003e specifies a \u003cstrong\u003e3300 XL 25 mm Proximitor Sensor\u003c\/strong\u003e configured with a 9.0 m system length and DIN rail mounting, intended for installations requiring no hazardous area certifications.\u003c\/p\u003e\n\u003cp\u003eThis sensor forms an integral part of the 3300 XL 25 mm Proximity Transducer System, which is designed for non-contact, large-target eddy-current displacement measurements, specifically for steam turbine differential expansion (DE) and casing expansion. By processing the high-frequency RF signal from a 330851 proximity probe and 330854 extension cable, the Proximitor sensor provides a scaled analog output of 0.787 V\/mm (20 mV\/mil). Compared to panel-mount or alternative 5.0 m configurations, this 9.0 m DIN-mount version offers extended system reach and convenient standard DIN rail installation inside local instrument enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 91 specifies a 9.0 m system length with integrated DIN rail mounting hardware.\u003c\/li\u003e\n\u003cli\u003eOption 00 provides a standard configuration without hazardous area agency approvals.\u003c\/li\u003e\n\u003cli\u003eCompatible with the Bently Nevada 3300 XL 25 mm series proximity probes and extension cables.\u003c\/li\u003e\n\u003cli\u003eDelivers a nominal Average Scale Factor of 0.787 V\/mm (20 mV\/mil) over a 12.7 mm (500 mils) linear range.\u003c\/li\u003e\n\u003cli\u003eAccepts power supply inputs ranging from -17.5 Vdc to -26 Vdc.\u003c\/li\u003e\n\u003cli\u003eMaintains a constant 50 ohm output resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine differential expansion (DE) monitoring\u003c\/li\u003e\n\u003cli\u003eRotor casing expansion measurement\u003c\/li\u003e\n\u003cli\u003eLarge-target eddy-current displacement applications\u003c\/li\u003e\n\u003cli\u003eSteam turbine thrust position monitoring\u003c\/li\u003e\n\u003cli\u003eHeavy industrial rotating machinery protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330850-91-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption AA - Total Length and Mounting\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003ctd\u003e9.0 metres (29.5 feet) system length, DIN mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption BB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e330850-91-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Proximity Transducer System (330851 probes, 330854 cables)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Supply\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e12.7 mm (500 mils), beginning at approximately 0.63 mm (25 mils) from target (from 0.63 to 13.33 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003eApproximately -1.5 Vdc to -11.5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Scale Factor (ASF)\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.31 mm (+\/-12 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 2.7 kHz (+0, -3 dB typical with up to 305 metres of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Minimum Target Size\u003c\/td\u003e\n\u003ctd\u003e61 mm (2.4 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Sensor Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +100 Celsius (-60 Fahrenheit to +212 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +105 Celsius (-60 Fahrenheit to +221 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (tested to IEC 68-2-3 damp heat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e9.0 m (combined probe and extension cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail mount (Option 91)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eNone (Option 00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz) (sensor only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor optimal installation of the 330850 DIN-mount Proximitor sensor, ensure it is secure on a standard 35 mm DIN rail. Secure the field wiring terminals (0.2 to 1.5 mm2 or 16 to 24 AWG) using a shielded triad cable with a maximum length of 305 metres (1000 feet) to the monitoring system. Keep the coaxial connectors between the extension cable and the probe finger-tight, or torque to a maximum of 0.565 N-m (5 in-lb). The Proximitor must be housed in a clean, dry enclosure providing at least IP54 protection to prevent exposure to moisture and contamination.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis device complies with the European CE mark requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666545471851,"sku":"330850-91-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330850-91-00-3300-xl-25-mm-proximitor-sensor-kqn4tpazt2e_52780fc8-0130-4fce-befe-d29ffb0c362a.jpg?v=1765440516"},{"product_id":"bently-nevada-89477-50-velomitor-piezo-velocity-sensor","title":"Bently Nevada 89477-50 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e89477-50\u003c\/strong\u003e is a specialized, rugged industrial \u003cstrong\u003eVelomitor piezo-velocity sensor\u003c\/strong\u003e engineered to measure total vibration velocity directly on the casings of rotating machinery. Unlike traditional moving-coil velocity transducers, this solid-state instrument utilizes internal piezoelectric crystals integrated with an onboarding charge amplifier circuit to process raw vibration accelerations and output an integrated, linear voltage velocity signal. The \u003cstrong\u003e89477-50\u003c\/strong\u003e provides continuous casing vibration data across high-speed machinery drops, routing the dynamic signal path directly to specialized machinery protection monitors, programmable logic controllers (PLCs), or distributed control systems (DCSs). By integrating the processing electronics inside a hermetically sealed enclosure, it minimizes moving mechanical parts wear and eliminates the orientation limitations typical of mechanical design configurations. It features a specific design revision optimized for extreme-temperature deployment, standard mounting thread patterns, and a standard top-connector interface block to stream clean predictive maintenance variables directly to host processing racks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSolid-state piezoelectric integration converting raw acceleration to linear velocity outputs without moving parts.\u003c\/li\u003e\n\u003cli\u003eHigh-temperature specialized design variant tailored for high-thermal machine casings and harsh plant fields.\u003c\/li\u003e\n\u003cli\u003eHermetically sealed physical housing preventing moisture, oil ingress, and airborne particulate degradation.\u003c\/li\u003e\n\u003cli\u003eDirect compatibility with standard machine protection monitors and asset analysis instrumentation racks.\u003c\/li\u003e\n\u003cli\u003eEliminates physical mounting orientation constraints, allowing omnidirectional installation angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous casing velocity monitoring and unbalanced mass tracking on industrial gas and steam turbines.\u003c\/li\u003e\n\u003cli\u003eStructural casing vibration safety loops on heavy-duty induction motors, large pumps, and process fans.\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance diagnostics on high-vibration balance-of-plant rotating machinery skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477 (High Temperature Velomitor Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Assembly Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Option Suffix Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-50 (Specialized High Temperature \/ Mounting Variant Code)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiezoelectric Velocity Transducer (Velomitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Circuit Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal piezoelectric crystal element with integrated charge amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Output Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear voltage proportional to absolute casing velocity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCasing vibration velocity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstrument Physical Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-state construction with no internal moving components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Sealing Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHermetically sealed housing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Interface Layout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop-mounted physical connector receptacle block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Envelope Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Option Specific Thread Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Mechanical Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCorrosion-resistant stainless steel or equivalent alloy shell structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Installation Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOmnidirectional operational deployment angle flexibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard field velocity transducer unit weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTop Connector Pins\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePinout paths for dynamic voltage signal output and circuit power input loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Base Baseplate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThreaded mechanical interface for rigid attachment to machine casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRigid Casing Mounting:\u003c\/strong\u003e Mount the sensor base directly onto a flat, unpainted, cleanly tapped surface on the machine bearing housing. Torque the sensor casing down to standard engineering layout criteria to maximize dynamic signal transfer accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing Paths:\u003c\/strong\u003e Route the interconnecting sensor lead wire through standard flexible conduit blocks. Keep the signal cables isolated from parallel high-voltage motor electrical conduits to minimize electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Strain Relief:\u003c\/strong\u003e Support the mating top connector shell properly to prevent physical strain loop forces from wearing out the sensor internal pin contacts during prolonged high-vibration exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Mitigation:\u003c\/strong\u003e Verify that the maximum operational surface temperature does not exceed the designated thermal rating boundary of this high-temperature configuration during sustained peak operation loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666545537387,"sku":"89477-50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-89477-50-velomitor-piezo-velocity-sensor-xhdjozvfmiq_7b8b461d-1d49-4e77-b2c7-53b1434cc3d3.jpg?v=1765440519"},{"product_id":"bently-nevada-330180-x1-05mod-145004-83-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05MOD：145004-83 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e330180-X1-05MOD:145004-83\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL 8 mm Proximitor Sensor\u003c\/strong\u003e component designed for integration into eddy-current proximity transducer systems. This unit provides non-contact displacement measurement for critical rotating machinery, including turbine and compressor shaft vibration and axial position monitoring. This specific configuration incorporates custom modifications (MOD:145004) to meet specialized installation or performance requirements within 3300 XL monitoring chains.\n\nThe Proximitor sensor is a core element of the transducer chain, consisting of a probe, extension cable, and this Proximitor unit. It conditions the high-frequency RF signal from the probe and outputs a proportional voltage signal to monitoring systems. The 3300 XL platform is known for its electrical compatibility and consistency, allowing for interchangeable probes and cables without requiring recalibration of the Proximitor sensor, provided the system length remains matched (typically 5 meters or 9 meters total).\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximitor Sensor:\u003c\/strong\u003e 3300 XL 8 mm compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom Configuration:\u003c\/strong\u003e Includes MOD:145004 specification for specific application requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Type:\u003c\/strong\u003e Non-contact eddy-current displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Designed for use with 3300 XL 8 mm probes and extension cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Consistent output scaling across 3300 XL system components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFluid film bearing health monitoring in turbines and compressors\u003c\/li\u003e\n\u003cli\u003eShaft axial position and vibration measurement\u003c\/li\u003e\n\u003cli\u003eRotating machinery protection in power generation, petrochemical, and oil and gas industries\u003c\/li\u003e\n\u003cli\u003eCritical equipment monitoring utilizing the 3300 XL 8 mm transducer platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCode on This SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145004-83\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximitor Sensor (Custom)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSegment A (Mounting\/Length)\u003c\/td\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eCustom Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSegment B (Modification)\u003c\/td\u003e\n\u003ctd\u003e05MOD:145004\u003c\/td\u003e\n\u003ctd\u003eModified Version 145004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSegment C\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003ctd\u003eCustom Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145004-83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel or DIN rail compatible (depending on housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the Proximitor sensor is installed in an area free from excessive moisture and corrosive environments.\u003c\/li\u003e\n\u003cli\u003eUse appropriate Bently Nevada housing (e.g., 3300 XL Multi-Purpose Housing) for hazardous area installations.\u003c\/li\u003e\n\u003cli\u003eEnsure that the total system length (Probe + Extension Cable + Proximitor) matches the calibrated 5 m or 9 m standard.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding and shielding practices to prevent electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConsult the 3300 XL 8 mm Transducer System Manual (Document 141194) for specific wiring and terminal strip instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE compliant\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eCSA, ATEX, IECEx rated (verify full system compatibility based on installation drawing)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666545602923,"sku":"330180-X1-05 MOD：145004-83","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145004-83-proximitor-sensor-o0jqobjzfeb_e3ef2723-90ea-4bf9-9b1b-237d710c98bd.jpg?v=1765440521"},{"product_id":"bently-nevada-330500-05-01-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-05-01 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330500-05-01\u003c\/strong\u003e: Bently Nevada Velomitor \u003cstrong\u003epiezo-velocity sensor\u003c\/strong\u003e configured with Option 05 mounting thread adaptor (unavailable for standard 330500, directing NPT installations to model 330525) and Option 01 CSA\/US\/C hazardous area certification.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration incorporates a hermetically-sealed 316L stainless steel case housing embedded solid-state electronics, making it immune to mechanical wear and degradation. Unlike moving-parts velocity transducers, this piezo-velocity sensor can be mounted at any orientation angle. The sensor provides an output sensitivity of 3.94 mV\/mm\/s (100 mV\/in\/s) to measure absolute structural, casing, or bearing housing vibration in demanding industrial machinery environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 05 mounting thread option indicating specialized configuration or standard adapter substitution.\u003c\/li\u003e\n  \u003cli\u003eOption 01 CSA\/US\/C hazardous area approval package for Class I, Division 1 (Groups A, B, C, D) locations.\u003c\/li\u003e\n  \u003cli\u003eSolid-state piezoelectric design with no moving parts to prevent mechanical wear and degradation.\u003c\/li\u003e\n  \u003cli\u003e3.94 mV\/mm\/s (100 mV\/in\/s) output sensitivity with plus or minus 5% accuracy.\u003c\/li\u003e\n  \u003cli\u003eBroad frequency response from 4.5 Hz to 5 kHz (plus or minus 3.0 dB) or 6.0 Hz to 2.5 kHz (plus or minus 0.9 dB).\u003c\/li\u003e\n  \u003cli\u003eCase-isolated electrical grounding to prevent noise interference.\u003c\/li\u003e\n  \u003cli\u003eHermetically-sealed 316L stainless steel case with a 2-pin Mil-C-5015 receptacle connector.\u003c\/li\u003e\n  \u003cli\u003eOperating temperature range of -55 degC to 121 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft casing, structural, or bearing housing vibration monitoring.\u003c\/li\u003e\n  \u003cli\u003eRotating machinery protection (unbalance, misalignment, rotor faults).\u003c\/li\u003e\n  \u003cli\u003ePower generation, oil and gas, petrochemical, and other heavy-industry environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330500-05-01\u003c\/td\u003e\n      \u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Mounting Thread Adaptor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eUnavailable for 330500 (Note: For 1\/4-18 NPT mounting, order 330525).\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eCSA\/US\/C (Class I, Div 1 Groups A, B, C, D; Class II, Groups E, F, G; Class III).\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330500-05-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) plus or minus 5%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.5 Hz to 5 kHz (270 cpm to 300 kcpm) plus or minus 3.0 dB; 6.0 Hz to 2.5 kHz (360 cpm to 150 kcpm) plus or minus 0.9 dB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperature Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-14% to +7.5% typical over the operating temperature range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVelocity Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 5% of sensitivity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmplitude Linearity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eplus or minus 2% to 152 mm\/s (6 in\/s) peak\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounted Resonant Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGreater than 12 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Bias Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-12 plus or minus 3.0 VDC over temperature referenced to Pin A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDynamic Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2400 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBroadband Noise Floor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.004 mm\/s (160 u in\/s) rms, nominal (4.5 Hz to 5 kHz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCase isolated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 m (1,000 ft) of cable (part number 02173006) with no signal degradation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-55 degC to 121 degC (-67 degF to 250 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShock Survivability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5,000 g peak, maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTo 100% non-submerged (hermetically-sealed case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Strain Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.005 in\/s\/mstrdin.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMagnetic Field Susceptibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 51 micro-in\/s\/gauss (50 gauss, 50-60 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e316L stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2-pin Mil-C-5015 hermetically-sealed, 316L stainless steel shell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e32-46 kg cm (24-40 in-lb) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePolarity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWhen the sensor case motion is toward the connector, Pin A becomes positive with respect to Pin B\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Pin\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin A\u003c\/td\u003e\n      \u003ctd\u003eSignal \/ Positive Output (referenced for output bias voltage; becomes positive with respect to Pin B when motion is toward connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin B\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Return\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the sensor on a flat, clean surface of the bearing housing or machine casing to maintain optimal amplitude and frequency response.\u003c\/li\u003e\n  \u003cli\u003eApply mounting torque within the specified range of 32 to 46 kg-cm (24 to 40 in-lb) maximum. Do not exceed these limits.\u003c\/li\u003e\n  \u003cli\u003eEnsure proper electrical shielding. The sensor case is electrically isolated, requiring proper termination of the cable shield to prevent noise.\u003c\/li\u003e\n  \u003cli\u003eAvoid integrating the sensor output to measure displacement unless electrical noise from interference is actively mitigated.\u003c\/li\u003e\n  \u003cli\u003eUse only compatible twisted, shielded 2-conductor cable assemblies (such as Bently Nevada part number 02173006) for connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA\/NRTL\/C:\u003c\/strong\u003e Class I, Div 1 Groups A, B, C, D; Class II, Groups E, F, G; Class III (Ex ia IIC T3, AEx ia IIC T3, Temp Code T3 @ -55 degC to 121 degC).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e 2014\/30\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Part 15 Compliant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e ABS Marine Vessels, Offshore Units and Structures, Mobile Offshore Units.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666549469547,"sku":"330500-05-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-05-01-sensor-proximity-aenpl1pyaw2_c62f1aad-fad5-4607-ad7b-f925638c9b9d.jpg?v=1765440578"},{"product_id":"bently-nevada-330180-080-03-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-080-03-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330180-080-03-05\u003c\/strong\u003e is a 3300 XL Proximitor sensor component for the Bently Nevada 3300 XL 8 mm Proximity Transducer System. This device serves as the signal conditioning interface between the probe and the monitoring system, converting the eddy-current displacement measurement from the probe into a voltage output signal proportional to the distance between the probe tip and the observed conductive surface.\u003c\/p\u003e\n\n\u003cp\u003e3300 XL Proximitor sensors utilize advanced circuitry to maintain system accuracy and temperature stability. This configuration is compatible with 3300 XL 8 mm probes and extension cables to provide reliable vibration and axial position measurement for critical rotating machinery, such as steam turbines, gas compressors, and centrifugal pumps. The 3300 XL system is engineered to function within the 3300 monitoring chains, ensuring consistent performance and compatibility with Bently Nevada machinery protection and condition monitoring hardware.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use with 3300 XL 8 mm proximity probes and 3300 XL extension cables\u003c\/li\u003e\n\u003cli\u003eProvides voltage output proportional to shaft displacement for vibration and position monitoring\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Bently Nevada 3300 monitoring rack interfaces\u003c\/li\u003e\n\u003cli\u003eSupports hazardous area installations when used with approved components\u003c\/li\u003e\n\u003cli\u003eElectromagnetic compatibility (EMC) designed for industrial machinery environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCritical machinery protection for turbines, compressors, and generators\u003c\/li\u003e\n\u003cli\u003eShaft radial vibration monitoring for sleeve bearing machines\u003c\/li\u003e\n\u003cli\u003eAxial position (thrust) measurement for rotor displacement\u003c\/li\u003e\n\u003cli\u003eDifferential expansion measurements in rotating equipment\u003c\/li\u003e\n\u003cli\u003eHigh-temperature or harsh industrial environment monitoring installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-080-03-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330180-080-03-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Probes and Extension Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eProportional Voltage (Displacement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx (per Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the total system length (probe plus extension cable) matches the requirements of the Proximitor sensor. Proper grounding and shielding are required for the installation of the signal cable between the sensor and the monitoring system. The sensor should be mounted in a protected location, ideally within a Bently Nevada approved housing, to avoid direct exposure to process fluids or harsh environmental conditions. Always verify that the probe gap is set correctly according to the system manual for the specific machine application.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666553827691,"sku":"330180-080-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-080-03-05-3300-xl-proximitor-sensor-oqbbc504qxv_17143381-f4bc-4211-a834-b68e221d9934.jpg?v=1765440598"},{"product_id":"bently-nevada-330500-01-05-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-01-05 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330500-01-05\u003c\/strong\u003e is a high-performance \u003cstrong\u003eVelomitor Piezo-velocity Sensor\u003c\/strong\u003e configured with a 1\/2-20 UNF mounting thread (Option 01). This sensor is designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration. By incorporating a solid-state piezoelectric accelerometer with embedded integrated electronics, the 330500 provides a reliable, non-contact measurement solution that eliminates the mechanical degradation and wear typically associated with moving parts.\u003c\/p\u003e\n\n\u003cp\u003eThis transducer is suitable for horizontal, vertical, or angular orientation, allowing for versatile installation on machine housings. It is specifically engineered to transmit rotor vibration data to the casing, enabling effective overall machine protection monitoring for industrial rotating equipment. The 330500 series is built for use in demanding environments, offering significant resistance to electrical noise and interference when installed according to standard Bently Nevada instrumentation guidelines.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated solid-state design with no moving parts, eliminating mechanical wear\u003c\/li\u003e\n\u003cli\u003eStandard 1\/2-20 UNF mounting thread (Option 01)\u003c\/li\u003e\n\u003cli\u003eHermetically sealed 316L stainless steel case for environmental protection\u003c\/li\u003e\n\u003cli\u003eTwo-pin MIL-C-5015 connector interface\u003c\/li\u003e\n\u003cli\u003eWide frequency response (4.5 Hz to 5 kHz) for comprehensive vibration analysis\u003c\/li\u003e\n\u003cli\u003eRobust shock survivability up to 5,000 g peak\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower generation and turbine-generator sets\u003c\/li\u003e\n\u003cli\u003ePetrochemical and oil and gas rotating equipment\u003c\/li\u003e\n\u003cli\u003eBearing housing and casing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eWater treatment and industrial pump protection\u003c\/li\u003e\n\u003cli\u003eGeneral purpose industrial machinery monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-01-05\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e1\/2-20 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (+\/- 3.0 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResonant Frequency\u003c\/td\u003e\n\u003ctd\u003eGreater than 12 kHz (mounted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to +121 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin Mil-C-5015 hermetically sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.142 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.3 mm diameter x 63.2 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the sensor is mounted on a flat, clean surface of the bearing housing or machine casing to maintain frequency response accuracy. Use appropriate mounting torque (32-46 kg cm or 24-40 in-lb) to prevent false signals. For hazardous area installations, always refer to the specific entity parameters and the current 330500 installation drawing provided by the manufacturer. Grounding is achieved via the case; ensure the mounting interface provides a solid electrical path if case grounding is required.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Mark\u003c\/li\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eABS Marine Vessels compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666553893227,"sku":"330500-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-01-05-velomitor-piezo-velocity-sensor-tspqthgna1n_230c1ff2-5655-4098-8915-ee28fb159823.jpg?v=1765440600"},{"product_id":"bently-nevada-330500-04-00-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-04-00 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e330500-04-00\u003c\/strong\u003e is a high-precision \u003cstrong\u003eVelomitor Piezo-velocity sensor\u003c\/strong\u003e configured with a 1\/4-20 UNC mounting thread adapter (Option 04) and no agency approval (Option 00). This sensor is engineered to measure absolute bearing housing, casing, and structural vibration, providing reliable monitoring data for rotating machinery. As a specialized piezoelectric accelerometer with integrated solid-state electronics, the unit contains no moving parts, preventing mechanical degradation and ensuring a long service life in diverse industrial environments.\n\nThe 330500 series is suitable for vertical, horizontal, or angled mounting orientations. For optimal signal integrity, it is recommended to install the sensor directly on the machine casing or bearing housing; improper installation can potentially dampen the frequency response or introduce false signals. This configuration, featuring the 1\/4-20 UNC adapter, is typically used in applications where specific fastener compatibility is required for secure mechanical attachment.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 04: Includes 1\/4-20 UNC mounting thread adapter for specific installation requirements.\u003c\/li\u003e\n\u003cli\u003eOption 00: Standard configuration without hazardous area agency approvals.\u003c\/li\u003e\n\u003cli\u003eSolid-state design with no moving parts, eliminating mechanical wear and degradation.\u003c\/li\u003e\n\u003cli\u003e316L stainless steel, hermetically sealed case for durability in industrial settings.\u003c\/li\u003e\n\u003cli\u003eBroad frequency response range of 4.5 Hz to 5 kHz (±3.0 dB).\u003c\/li\u003e\n\u003cli\u003eCase-isolated grounding to prevent ground loop interference.\u003c\/li\u003e\n\u003cli\u003eStandard 2-pin MIL-C-5015 hermetically sealed connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe Velomitor Piezo-velocity sensor is used extensively in heavy industry for casing vibration monitoring, including:\n\u003cul\u003e\n\u003cli\u003ePower generation equipment monitoring\u003c\/li\u003e\n\u003cli\u003eOil and gas turbomachinery protection\u003c\/li\u003e\n\u003cli\u003ePetrochemical and industrial pump monitoring\u003c\/li\u003e\n\u003cli\u003eRotating machinery balance and alignment verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-04-00\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread Adapter\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e1\/4-20 UNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330500-04-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (±3.0 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015 hermetically sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to 121 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e142 g (0.142 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.3 mm diameter x 63.2 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e32-46 kg cm (24-40 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666556809579,"sku":"330500-04-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-04-00-velomitor-piezo-velocity-sensor-hqs2k5lnlkz_c9159114-b65d-41cd-84f3-c818b5583c49.jpg?v=1765440626"},{"product_id":"bently-nevada-330500-06-02-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-06-02 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330500-06-02\u003c\/strong\u003e: This Bently Nevada Velomitor Piezo-velocity sensor is configured with a 5\/8-18 UNF mounting thread (Option 06) and ATEX (European) hazardous area approvals (Option 02). It is a specialized piezoelectric accelerometer featuring embedded integrated electronics within a solid-state design, suitable for measuring absolute bearing housing, casing, or structural vibration.\u003c\/p\u003e\n\u003cp\u003eAs a solid-state device without moving parts, the 330500 does not suffer from mechanical wear or degradation. It offers flexible installation, allowing for vertical, horizontal, or angled orientation. This sensor effectively monitors machinery malfunctions such as unbalance and misalignment by capturing vibration transmitted to the machine casing or mounting location.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting (Option 06)\u003c\/strong\u003e: 5\/8-18 UNF thread adapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval (Option 02)\u003c\/strong\u003e: ATEX (European) certification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid-State Design\u003c\/strong\u003e: No moving parts, eliminating mechanical degradation and wear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Mounting\u003c\/strong\u003e: Orientation independent (vertical, horizontal, or angled).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction\u003c\/strong\u003e: 316L stainless steel housing with hermetically-sealed connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e: 100 mV\/in\/s (3.94 mV\/mm\/s) sensitivity for consistent monitoring data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eDesigned for industrial rotating machinery protection, this sensor is used in environments such as power generation, petrochemical plants, and oil and gas facilities. It is ideal for monitoring absolute casing vibration on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBearing housings\u003c\/li\u003e\n\u003cli\u003eStructural machine frames\u003c\/li\u003e\n\u003cli\u003ePumps, fans, and motors\u003c\/li\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-06-02\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting\u003c\/td\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e5\/8-18 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX (European)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330500 Velomitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz +\/- 3.0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin Mil-C-5015 hermetically-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-55 degC to 121 degC (-67 degF to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.142 kg (142 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.3 mm diameter x 63.2 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eCase isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure installation on the bearing housing or machine casing. Improper mounting may decrease frequency response and generate false signals. Adhere to specified mounting torque of 32-46 kg cm (24-40 in-lb). For hazardous area installations, ensure connections meet ATEX safety requirements as per local regulations and documentation.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eATEX (Option 02)\u003c\/strong\u003e: Certified for European hazardous areas. Additional compliance includes CE, RoHS, and maritime approvals (ABS Marine Vessels, Offshore Units and Structures).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666557170027,"sku":"330500-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-06-02-sensor-proximity-ukenfazxypd_ca22be89-47c5-4f13-b3d1-e93aae14ce6b.jpg?v=1765440635"},{"product_id":"bently-nevada-330500-04-04-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-04-04 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330500-04-04\u003c\/strong\u003e Velomitor Piezo-velocity Sensor is a specialized piezoelectric accelerometer designed for measuring absolute casing, bearing housing, and structural vibration. This configuration features a 1\/4-20 UNC mounting thread adapter (Option 04) and is rated for multiple hazardous area approvals (Option 04: CSA, ATEX), allowing for versatile installation in demanding industrial environments.\u003c\/p\u003e\n\n\u003cp\u003eThe 330500 incorporates solid-state piezoelectric technology with embedded integrated electronics. With no moving parts, the sensor is resistant to mechanical wear and can be mounted in any orientation—vertical, horizontal, or angled. It is a critical component for machinery protection systems where continuous transmission of casing vibration is required to monitor for malfunctions such as unbalance or misalignment.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1\/4-20 UNC mounting thread adapter (Option 04)\u003c\/li\u003e\n\u003cli\u003eCSA and ATEX hazardous area approvals (Option 04)\u003c\/li\u003e\n\u003cli\u003eSolid-state piezoelectric design with no moving parts\u003c\/li\u003e\n\u003cli\u003eHermetically-sealed 316L stainless steel housing\u003c\/li\u003e\n\u003cli\u003e2-pin MIL-C-5015 connector interface\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Bently Nevada monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAbsolute (relative to free space) bearing housing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eCasing vibration measurement for industrial rotating machinery\u003c\/li\u003e\n\u003cli\u003eStructural vibration analysis in petrochemical and power generation facilities\u003c\/li\u003e\n\u003cli\u003eGeneral purpose velocity measurement for machine protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-04-04\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread Adapter\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e1\/4-20 UNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals (CSA, ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (+\/- 3.0 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude Linearity\u003c\/td\u003e\n\u003ctd\u003e+\/- 2% to 152 mm\/s (6 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Bias Voltage\u003c\/td\u003e\n\u003ctd\u003e-12 +\/- 3.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to 121 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e32-46 kg cm (24-40 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.142 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.3 mm diameter x 63.2 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the sensor is installed directly on the bearing housing or machine casing. Improper installation, such as loose mounting or poor surface contact, may decrease amplitude and frequency response or generate false signals. Use the provided 1\/4-20 UNC mounting adapter and adhere to the specified mounting torque of 32-46 kg cm. Always consult the 330500 user manual for hazardous area installation instructions corresponding to the selected approval rating.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA \/ NRTL \/ C\u003c\/li\u003e\n\u003cli\u003eATEX Directive 2014\/34\/EU\u003c\/li\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eABS Marine Vessels \/ Mobile Offshore Units\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666557464939,"sku":"330500-04-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-04-04-velomitor-velocity-sensor-zq0lrjbj15e_af732f7a-e9b1-4547-b497-93e3788befc4.jpg?v=1765440637"},{"product_id":"bently-nevada-330500-07-00-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-07-00 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330500-07-00\u003c\/strong\u003e is a specialized \u003cstrong\u003eVelomitor Piezo-velocity Sensor\u003c\/strong\u003e designed for measuring absolute casing vibration on industrial machinery. This configuration includes the \u003cstrong\u003e3\/8-16 UNC\u003c\/strong\u003e mounting thread adapter (Option 07) and comes with no hazardous area agency approvals (Option 00). As a solid-state piezoelectric accelerometer with integrated electronics, this sensor provides a velocity-proportional output without mechanical moving parts, ensuring consistent performance in challenging environments where traditional velocity transducers might suffer from mechanical wear.\u003c\/p\u003e\n\n\u003cp\u003eEngineered for high reliability in rotating machinery protection, the 330500 system detects casing vibration caused by common malfunctions such as rotor unbalance or misalignment. It is compatible with a wide range of Bently Nevada monitoring systems and can be mounted in any orientation. The sensor is constructed from 316L stainless steel and is hermetically sealed to withstand harsh industrial conditions while maintaining signal integrity for monitoring and protection applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Option 07:\u003c\/strong\u003e Equipped with a 3\/8-16 UNC mounting thread adapter for secure installation on bearing housings or machine casings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval 00:\u003c\/strong\u003e Standard configuration with no specific hazardous area certifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid-State Design:\u003c\/strong\u003e Contains no moving parts, eliminating mechanical degradation and enabling versatile mounting orientations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e Provides 100 mV\/in\/s sensitivity with a frequency response range of 4.5 Hz to 5 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Housed in a hermetically sealed 316L stainless steel body to protect against environmental contaminants and mechanical shock (up to 5,000 g).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Versatility:\u003c\/strong\u003e Suitable for a wide operating temperature range from -55 degC to 121 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAbsolute (casing) vibration measurement on rotating machinery.\u003c\/li\u003e\n\u003cli\u003eMonitoring bearing housings for structural vibration.\u003c\/li\u003e\n\u003cli\u003eDetection of rotor-related malfunctions such as unbalance and misalignment.\u003c\/li\u003e\n\u003cli\u003eIndustrial environments requiring high-frequency response and durability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-07-00\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread\u003c\/td\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e3\/8-16 UNC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330500-07-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (+\/- 3.0 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to 121 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e142 g (5.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e32-46 kg cm (24-40 in-lb) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Survivability\u003c\/td\u003e\n\u003ctd\u003e5,000 g peak maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the sensor directly onto the bearing housing or machine casing for effective vibration transmission. Improper mounting may attenuate the signal or introduce false readings.\u003c\/li\u003e\n\u003cli\u003eEnsure the mating surface is flat and clean before tightening to the specified mounting torque.\u003c\/li\u003e\n\u003cli\u003eUtilize appropriate twisted, shielded cables to minimize electrical interference and noise, especially when integrating the output for displacement measurement.\u003c\/li\u003e\n\u003cli\u003eThe sensor is case-isolated; ensure grounding is handled according to the specific facility wiring requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666561954155,"sku":"330500-07-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-07-00-velomitor-piezo-velocity-sensor-aovvb1hakxk_c39eb031-bd6a-4bb6-8d30-2b422dd23f41.jpg?v=1765440664"},{"product_id":"bently-nevada-330500-01-01-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-01-01 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e330500-01-01\u003c\/strong\u003e is a \u003cstrong\u003eVelomitor Piezo-velocity Sensor\u003c\/strong\u003e designed for measuring absolute casing or structural vibration on rotating machinery. This specific configuration features a 1\/2-20 UNF mounting thread (Option 01) and CSA\/US\/C agency approvals (Option 01). Built as a specialized piezoelectric accelerometer with integrated electronics, the 330500 provides a reliable, solid-state solution for machinery protection.\n\nUnlike traditional velocity transducers with moving parts that degrade over time, the 330500 sensor is entirely solid-state. It features a robust 316L stainless steel, hermetically sealed housing, allowing for vertical, horizontal, or any other orientation without affecting performance. The unit is used to monitor machine malfunctions such as unbalance and misalignment by detecting changes in casing vibration, making it an essential component in critical machinery monitoring chains.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1\/2-20 UNF mounting thread (Option 01) for standard stud installation\u003c\/li\u003e\n\u003cli\u003eCSA\/US\/C agency approval (Option 01) for hazardous area compliance\u003c\/li\u003e\n\u003cli\u003eSolid-state design with no moving parts to ensure longevity and minimize mechanical wear\u003c\/li\u003e\n\u003cli\u003e316L stainless steel, hermetically sealed housing for durability in harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eSensitivity of 100 mV\/in\/s (3.94 mV\/mm\/s) for accurate vibration measurement\u003c\/li\u003e\n\u003cli\u003e2-pin Mil-C-5015 connector for reliable signal transmission\u003c\/li\u003e\n\u003cli\u003eSuitable for horizontal, vertical, or angled orientation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower generation machinery\u003c\/li\u003e\n\u003cli\u003eHydroelectric turbines\u003c\/li\u003e\n\u003cli\u003ePetrochemical processing equipment\u003c\/li\u003e\n\u003cli\u003eGeneral rotating machinery protection (fans, pumps, motors)\u003c\/li\u003e\n\u003cli\u003eBearing housing and structural vibration monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-01-01\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e1\/2-20 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/US\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\/Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-01-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV\/in\/s (3.94 mV\/mm\/s) +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (+\/- 3.0 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin Mil-C-5015, hermetically sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to 121 degC (-67 degF to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e142 g (0.142 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e25.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e63.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e32-46 kg cm (24-40 in-lb) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eCase isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA\/US\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the sensor is installed on a flat, clean surface on the bearing housing or machine casing for optimal frequency response.\u003c\/li\u003e\n\u003cli\u003eUse the specified 1\/2-20 UNF mounting adapter (Option 01) and observe the maximum mounting torque of 32-46 kg cm (24-40 in-lb) to prevent damage.\u003c\/li\u003e\n\u003cli\u003eAvoid over-tightening or using improper adapters, which can lead to false signals or degraded amplitude response.\u003c\/li\u003e\n\u003cli\u003eIf integrating the output to measure displacement, be aware that electrical noise can be amplified; maintain proper cabling and shielding practices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\/US\/C (Option 01)\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eABS Marine Vessels compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666563494251,"sku":"330500-01-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-01-01-velomitor-velocity-sensor-j0riwsvw535_02c2f7d1-225d-4edf-8cc2-272352690831.jpg?v=1765440697"},{"product_id":"bently-nevada-330180-x1-cn-mod-145004-82-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-CN MOD 145004-82 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN MOD 145004-82\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a highly specialized 3300 XL Proximitor Sensor engineered for precise machinery protection in the most demanding industrial environments. This specific configuration is tailored for the Chinese market, meeting stringent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEPSI\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCC\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSRRC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eregulatory requirements for hazardous area operation and electromagnetic compatibility. Unlike standard proximity sensors calibrated for 4140 steel, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD 145004-82\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant is factory-calibrated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNi-Cr-Mo-V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Nickel-Chrome-Moly-Vanadium) target materials. This specialized calibration is critical for assets like high-pressure steam turbines or specialized compressors where exotic alloy shafts are utilized. By providing a linearized 7.87 V\/mm (200 mV\/mil) output against non-standard metallurgy, this sensor ensures the integrity of vibration and position data, preventing false trips or missed alerts in mission-critical rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Modification Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe technical complexity of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its specific ordering options and hardware modifications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX1 Modification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates a custom hardware configuration featuring DIN rail mounting for high-density cabinet installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN (China Specific Options):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNEPSI certified for explosive atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCCC mandatory safety certification and SRRC radio frequency approval.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChina RoHS compliant with a 50-year environment-friendly use period (EFUP).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD 145004-82:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates a factory modification to the Printed Wiring Assembly (PWA) and calibration process. This \"MOD\" replaces the standard 4140 steel working standard with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNi-Cr-Mo-V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etarget (Target CT # CT-0069), ensuring the 3300 XL system maintains its linear range across the specialized material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-X1-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModification Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMOD 145004-82\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNi-Cr-Mo-V (Nickel-Chrome-Molybdenum-Vanadium)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 metre (Standard 3300 XL 5mm\/8mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 to 2.3 mm (10 to 90 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Scale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Zero\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-3.0 VDC @ 20 mils\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEPSI, CCC, SRRC, China RoHS (50 years)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-17.5 VDC to -26 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the MOD 145004-82 required instead of a standard 330180?\u003c\/strong\u003eProximity sensors operate on eddy current principles, which are highly sensitive to target metallurgy. A standard sensor calibrated for 4140 steel will produce significant scale factor errors when measuring a Ni-Cr-Mo-V shaft. The MOD 145004-82 hardware is physically adjusted and calibrated to this specific alloy to ensure accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat system length must be used with this Proximitor?\u003c\/strong\u003ePer the labeling information, this unit is designed for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0 metre\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. You must use a 3300 XL 5mm or 8mm probe and extension cable that combine for a total electrical length of 9.0 metres to maintain calibration integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the -CN suffix affect international compliance?\u003c\/strong\u003eThe -CN suffix ensures the device is legal for installation within the People's Republic of China, meeting local explosive safety (NEPSI) and mandatory certification (CCC) laws. It is functionally equivalent to global 3300 XL sensors but carries the required local labeling and documentation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines and Safety Maintenance\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore installation, verify the shaft material metallurgy. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD 145004-82\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically for Ni-Cr-Mo-V. Using this sensor on 4140 steel or other alloys will result in incorrect vibration readings. Reference the job number (162282) and CT-0069 target code for your facility's asset records.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Zeroing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring commissioning, set the probe gap to achieve the electrical zero of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-3.0 VDC @ 20 mils\u003c\/strong\u003e. This ensures the measurement stays within the optimized linear range of the 3300 XL system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the DIN rail is properly bonded to the instrument earth. While the Proximitor housing is designed for isolation, proper rack grounding is essential to maintain the CCC\/SRRC electromagnetic compatibility standards and prevent signal noise in high-frequency switching environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor NEPSI-certified installations, ensure all cable glands and conduit seals meet the local explosion-proof requirements. Modification of the PWA (as specified in BOM 145004) must only be performed by Bently Nevada factory-authorized service centers to maintain the safety rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666564903275,"sku":"330180-X1-CN MOD 1450004-82","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-cn-mod-1450004-82-proximity-transducer-system-cuh4jpwij4o_a8068a52-102a-4284-8dbf-327a8ca368db.jpg?v=1765440720"},{"product_id":"bently-nevada-330780-51-05-3300-xl-11-mm-proximitor-sensor","title":"Bently Nevada 330780-51-05 3300 XL 11 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 51 (5.0 meter system length, DIN mount) and Option 05 (Multiple Approvals) specify this 3300 XL 11 mm Proximitor Sensor configuration — \u003cstrong\u003e330780-51-05\u003c\/strong\u003e. The 3300 XL 11 mm system features an incremental scale factor of 3.94 V\/mm (100 mV\/mil) for non-contact displacement and vibration measurements. The system is used on fluid-film bearing machines where an extended linear range is required, including turbine axial (thrust) position, ramp differential expansion, and reciprocating compressor rod drop monitoring.\u003c\/p\u003e\n\u003cp\u003eThis 330780-51-05 sensor processes the RF signal from a compatible 3300 XL 11 mm proximity probe and extension cable, outputting a voltage signal proportional to the distance between the probe tip and the observed shaft surface. The unit mounts on standard 35 mm DIN rails and is compatible with 3500 series machinery protection systems and secondary monitors.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 51 specifies a 5.0 meter (16.4 feet) system length combined with an integrated DIN-mount physical layout.\u003c\/li\u003e\n  \u003cli\u003eOption 05 delivers multiple international hazardous area agency approvals including ATEX, IECEx, and CSA.\u003c\/li\u003e\n  \u003cli\u003eGenerates a linear range of 4.0 mm (160 mils) for reliable tracking of larger rotor and shaft movements.\u003c\/li\u003e\n  \u003cli\u003eProvides an output scale factor of 3.94 V\/mm (100 mV\/mil) with high accuracy and low thermal drift.\u003c\/li\u003e\n  \u003cli\u003eEncased in an A380 aluminum housing for high mechanical integrity and environmental protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 330780-51-05 Proximitor Sensor is used in rotating machinery monitoring where an extended linear range is required. Typical application areas include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine axial (thrust) position and ramp differential expansion tracking\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor rod position and rod drop measurements\u003c\/li\u003e\n  \u003cli\u003eHigh-speed industrial turbine and compressor shaft vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eTachometer, phase reference (Keyphasor), and zero speed signal generation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe 330780-51-05 Proximitor Sensor is configured using the following structured options:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330780-51-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Total Length and Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e51\u003c\/td\u003e\n      \u003ctd\u003e5.0 meter (16.4 feet) system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e330780-51-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer System Type\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), beginning at approximately 0.5 mm (20 mils) from the target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eScale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10% (including interchangeability error)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Requirement\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA max; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Length Compatibility\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) total system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003eTested to IEC 68-2-3 damp heat\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz: +0, -3 dB typical (with up to 305 meters of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTerminal Blocks Torque Limit\u003c\/td\u003e\n      \u003ctd\u003e0.565 N-m (5 in-lb) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProximitor Weight\u003c\/td\u003e\n      \u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePhysical Dimensions (Option 51)\u003c\/td\u003e\n      \u003ctd\u003e31.7 mm x 70.8 mm x 89.4 mm (1.25 in x 2.79 in x 3.52 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003ePower Supply input\u003c\/td\u003e\n      \u003ctd\u003eNegative voltage supply (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon\u003c\/td\u003e\n      \u003ctd\u003eSystem common reference ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eSignal Output\u003c\/td\u003e\n      \u003ctd\u003eProportional dynamic voltage output (3.94 V\/mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation ensures stable, noise-free vibration and position data. Observe the following guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount on a standard 35 mm DIN rail. Ensure a physical clearance of at least 3.05 mm (0.12 in) is maintained above and below the mounting pad to allow easy removal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect using 0.2 to 1.5 mm2 (16 to 24 AWG) shielded three-conductor triad field wiring. Keep field wiring length under 305 meters (1000 feet) to prevent high-frequency signal attenuation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper shield terminal grounding at the monitor side only. Do not double-ground.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e If terminals are exposed to direct moisture or dust, the Proximitor must be installed within a protective enclosure providing at least IP54 protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330780-51-05 Proximitor Sensor has option 05 approvals, which verify compliance with multiple standard requirements:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Intrinsically Safe (Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc) and Non-Sparking\/Ec (Ex nA\/ec IIC T5...T1 Gc)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American (cNRTLus):\u003c\/strong\u003e Class I, Zone 0, AEx\/Ex ia IIC T4\/T5 Ga; Class I, Div 1, Groups A, B, C, D; Class I, Div 2, Groups A, B, C, D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions), CE compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (HFT = 0), SIL 3 compliant (HFT = 1)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with European Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565525867,"sku":"330780-51-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330780-51-05-3300-xl-11-mm-proximitor-sensor-dsdxsfliceq_4954eac2-4609-4073-b5a1-d5d247fbadeb.jpg?v=1765440728"},{"product_id":"bently-nevada-330180-x1-05mod-145347-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05MOD:145347-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-X1-05MOD:145347-05\u003c\/strong\u003e specifies this customized 3300 XL \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e configuration, featuring the X1 DIN-rail mount modification, standard Agency Approval Option 05, and a specialized target material calibration under Modification 145347 (Option 05).\u003c\/p\u003e\n\u003cp\u003eThis customized Proximitor sensor is calibrated as part of a specialized modification chain to ensure precise shaft vibration and axial position tracking when paired with 3300 XL 5 mm or 8 mm proximity probes and 9-meter extension cables. By departing from standard AISI 4140 steel calibration, this sensor corrects for the specific electrical conductivity and magnetic permeability of alternative rotor metallurgy, delivering a linear voltage output in critical turbomachinery applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDIN-Rail Mounting (X1 Option): Pre-configured with a secure mounting clip for direct installation onto standard 35 mm DIN rails, simplifying panel wiring.\u003c\/li\u003e\n  \u003cli\u003eMultiple Agency Approvals (Option 05): Certified for safe operation in hazardous industrial environments under ATEX, IECEx, and CSA standards.\u003c\/li\u003e\n  \u003cli\u003eCustom Target Calibration (Mod 145347-05): Adjusted circuit parameters to maintain scale factor accuracy over non-standard metallic targets.\u003c\/li\u003e\n  \u003cli\u003eSystem Integration: Houses the stable high-frequency oscillator and demodulator circuitry necessary to drive Bently Nevada eddy-current probes.\u003c\/li\u003e\n  \u003cli\u003eExcellent Noise Immunity: Designed with shielding and filtering that isolate the sensor output from electromagnetic and radio-frequency interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe sensor is ideal for turbomachinery monitoring in heavy-industry sectors such as oil and gas, petrochemicals, power generation, and water treatment. It is specifically applied where machinery shafts are composed of non-standard alloys rather than AISI 4140 steel, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine rotor displacement measurement\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor radial shaft vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eHigh-speed motor and pump axial thrust tracking\u003c\/li\u003e\n  \u003cli\u003eGearbox input and output shaft vibration diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSegment Code\u003c\/th\u003e\n      \u003cth\u003eThis SKU Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-X1-05MOD:145347-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 5mm\/8mm 9m Recalibrated Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment A: Total Length and Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eX1\u003c\/td\u003e\n      \u003ctd\u003eModification, DIN Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment B: Agency Approval and Mod Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05MOD:145347\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx) with custom recalibration modification family 145347\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment C: Target Material Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eOption 05 target material calibration under Modification 145347\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003e330180-X1-05MOD:145347-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDevice Type\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 5 mm \/ 8 mm (9-Meter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Configuration\u003c\/td\u003e\n      \u003ctd\u003eDIN-rail mount (X1 option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAgency Approvals\u003c\/td\u003e\n      \u003ctd\u003eOption 05 (Multiple Approvals: CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e10 to 90 mils (0.25 to 2.25 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Scale Factor\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Zero (E-zero)\u003c\/td\u003e\n      \u003ctd\u003e-3.0 Vdc @ 20 mils\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-51 to 100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 61.2 mm x 104.1 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the Proximitor sensor is mounted in a dry, clean enclosure or weather-proof housing to prevent moisture ingress. Maintain proper DIN rail grounding to protect signal integrity. Secure probe and extension cable coaxial connections with connector protectors or self-coalescing tape to insulate them from structural ground paths. Shielded field wiring must run back to the monitoring system to eliminate electromagnetic coupling.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eWhen ordered with Option 05, this device is certified for installation in hazardous locations under multiple international schemes:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA: Intrinsically Safe (Class I, Div 1, Groups A, B, C, D) and Non-Incendive (Class I, Div 2)\u003c\/li\u003e\n  \u003cli\u003eATEX \/ IECEx: Ex ia IIC T4 Ga (Zone 0) and Ex nA IIC T4 Gc (Zone 2)\u003c\/li\u003e\n  \u003cli\u003eCE Mark compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565722475,"sku":"330180-X1-05 MOD：145347-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145347-05-proximitor-sensor-sxketajhwsi_93f19dd0-0daa-4f7c-9dd2-163af19d0e56.jpg?v=1765440733"},{"product_id":"bently-nevada-330500-02-02-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-02-02 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330500-02-02\u003c\/strong\u003e Velomitor Piezo-velocity sensor is a high-precision, solid-state vibration transducer designed for measuring absolute casing and bearing housing vibration. This specific configuration features a M8 x 1 mounting adapter (Option 02) and is certified for ATEX European hazardous area installations (Option 02).\u003c\/p\u003e\n\n\u003cp\u003eBy incorporating integrated piezoelectric accelerometer technology, the 330500 series provides a velocity-proportional output without the use of moving parts, ensuring long-term stability and resistance to mechanical degradation. It is widely used in industrial machinery monitoring to detect malfunctions such as unbalance and misalignment by monitoring vibration transmitted to the machine casing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eM8 x 1 mounting thread adapter (Option 02)\u003c\/li\u003e\n\u003cli\u003eATEX (European) hazardous area approval (Option 02)\u003c\/li\u003e\n\u003cli\u003eSolid-state design with no moving parts for extended service life\u003c\/li\u003e\n\u003cli\u003e316L stainless steel hermetically sealed housing\u003c\/li\u003e\n\u003cli\u003e2-pin Mil-C-5015 electrical connector\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range from -55 degC to 121 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBearing housing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eMachine casing structural vibration measurement\u003c\/li\u003e\n\u003cli\u003eRotating machinery protection (pumps, compressors, fans, motors)\u003c\/li\u003e\n\u003cli\u003eGeneral industrial vibration analysis and maintenance programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-02-02\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread Adapter\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eM8 x 1 mounting adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX (European)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330500-02-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (+\/- 3.0 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to 121 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResonant Frequency\u003c\/td\u003e\n\u003ctd\u003eGreater than 12 kHz (mounted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e32-46 kg cm (24-40 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.142 kg (142 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin Mil-C-5015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin A\u003c\/td\u003e\n\u003ctd\u003ePositive Output (relative to Pin B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin B\u003c\/td\u003e\n\u003ctd\u003eCommon\/Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the sensor is mounted on a flat, clean surface on the bearing housing or machine casing. Use the provided M8 x 1 adapter to secure the sensor. Apply a mounting torque of 32-46 kg cm to ensure proper mechanical coupling. Improper installation, such as loose mounting or mounting on non-rigid surfaces, may decrease the transducer amplitude and frequency response, leading to inaccurate vibration readings.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX Directive 2014\/34\/EU\u003c\/li\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eFCC Compliance (Part 15)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566934891,"sku":"330500-02-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-02-02-vibration-sensor-fxt5f2n3ta1_9a779eb7-9f10-4642-bb57-59b6a9d3f2b6.jpg?v=1765440756"},{"product_id":"bently-nevada-330180-x1-05mod-145004-13-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05MOD:145004-13 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330180-X1-05MOD:145004-13\u003c\/strong\u003e is a 3300 XL Proximitor sensor configured for high-reliability vibration and position measurement applications. This unit is a critical component in 3300 XL 8 mm proximity transducer chains, facilitating non-contact eddy-current displacement monitoring on rotating machinery such as turbines, compressors, and pumps. This specific configuration supports standard system lengths and includes factory-specified modifications (MOD 145004) to meet unique installation requirements.\u003c\/p\u003e\n\n\u003cp\u003eThe Proximitor sensor conditions signals from the proximity probe, outputting a voltage proportional to the distance between the probe tip and the observed shaft. It is designed for seamless integration with 3300 XL probes and extension cables, ensuring linear, accurate signal transmission over specified distances. This sensor is encased in a robust housing suitable for panel or DIN-rail mounting, maintaining consistent performance in challenging industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for 3300 XL 8 mm proximity transducer systems\u003c\/li\u003e\n\u003cli\u003eSupports standard system lengths for 3300 XL measurement chains\u003c\/li\u003e\n\u003cli\u003eMOD 145004 specified configuration for application-specific requirements\u003c\/li\u003e\n\u003cli\u003eNon-contact eddy-current measurement for shaft vibration and axial position\u003c\/li\u003e\n\u003cli\u003ePanel or DIN-rail mountable for flexible installation\u003c\/li\u003e\n\u003cli\u003eCompatible with Bently Nevada 3300 XL extension cables and probes\u003c\/li\u003e\n\u003cli\u003eReliable signal conditioning for critical rotating machinery protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine and compressor shaft vibration monitoring\u003c\/li\u003e\n\u003cli\u003eRotor axial position measurement\u003c\/li\u003e\n\u003cli\u003eCritical machinery protection systems\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating equipment in power generation, oil and gas, and petrochemical sectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145004-13\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - System Length\/Mounting\u003c\/td\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eConsult factory for X1 segment configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Modification\u003c\/td\u003e\n\u003ctd\u003eMOD:145004\u003c\/td\u003e\n\u003ctd\u003eFactory modification (Special)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Suffix\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003eAdditional configuration identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145004-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Material\u003c\/td\u003e\n\u003ctd\u003eA308 Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Material\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass \/ Beryllium copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx (per Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 Celsius to +177 Celsius (Probe dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure all cable connections are finger-tight; use specified torque for non-XL stainless steel connectors if applicable.\u003c\/li\u003e\n\u003cli\u003eInstall in a dry, protected environment or within an appropriate Bently Nevada weather-proof housing.\u003c\/li\u003e\n\u003cli\u003eMaintain the correct system length by ensuring the sum of the probe and extension cable lengths matches the Proximitor sensor calibration.\u003c\/li\u003e\n\u003cli\u003eFollow hazardous area installation drawings (e.g., 141092, 140979) when applying for intrinsically safe or non-incendive installations.\u003c\/li\u003e\n\u003cli\u003eUse shielded, twisted-pair cabling for field wiring to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Compliant\u003c\/li\u003e\n\u003cli\u003eATEX\/IECEx (Option 05)\u003c\/li\u003e\n\u003cli\u003eCSA (Option 05)\u003c\/li\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eFunctional Safety (SIL 2 \/ SIL 3 capable)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666570146155,"sku":"330180-X1-05 MOD:145004-13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145004-13-3300-xl-proximitor-sensor-ghaemuuohcq_9540860d-ca75-47f3-8e42-0e0bed8ada77.jpg?v=1765440822"},{"product_id":"bently-nevada-330878-91-05-3300-xl-50-mm-proximitor-sensor","title":"Bently Nevada 330878-91-05 3300 XL 50 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 91 (9.0 meters system length, DIN mount) and Option 05 (Multiple Approvals) specify this 3300 XL 50 mm Proximitor Sensor configuration — \u003cstrong\u003e330878-91-05\u003c\/strong\u003e. This unit works with a 3300 XL 50 mm proximity probe and extension cable as part of a complete non-contact eddy-current displacement measurement system. It is used for shaft vibration and axial position measurement on large turbine rotors and machinery with oversized targets where displacement ranges exceed standard limits.\u003c\/p\u003e\n\u003cp\u003eUnlike variants configured for panel mounting (such as Option 90) or shorter 5.0-meter system lengths (such as Option 51), this specific configuration is tailored for DIN rail installation with a total system length of 9.0 meters. The integrated SpringLoc terminal strips facilitate fast field wiring connections without requiring specialized tools. Improved radio frequency interference (RFI) and electromagnetic interference (EMI) immunity allow this sensor to meet CE marking standards without specialized shield housing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 91 specifies a 9.0-meter system calibration designed for DIN rail mounting configurations.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides multiple agency approvals including ATEX, IECEx, and CSA hazardous area certifications.\u003c\/li\u003e\n  \u003cli\u003eExtended linear range of 27.9 mm (1100 mils) starting at 1.3 mm (50 mils) from the target.\u003c\/li\u003e\n  \u003cli\u003eAverage Scale Factor (ASF) of 394 mV\/mm (10 mV\/mil) nominal for high-displacement environments.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal strips simplify connection procedures and resist loosening under vibration.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in test points allow signal verification using standard instruments without interrupting field wiring.\u003c\/li\u003e\n  \u003cli\u003eBackward compatibility with standard 3300 XL 50 mm proximity probes and extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine generator set differential expansion (DE) monitoring\u003c\/li\u003e\n  \u003cli\u003eLarge industrial gas turbine rotor position measurements\u003c\/li\u003e\n  \u003cli\u003eAxial displacement monitoring on oversized shaft assemblies\u003c\/li\u003e\n  \u003cli\u003eHigh-displacement target tracking in power generation and petrochemical facilities\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery with heavy vibration and environmental exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330878-91-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximitor Sensor, DIN mount, 9.0 m system length, multiple approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e91\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx, etc.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-91-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one 3300 XL 50 mm proximity probe and extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length Calibration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers), 12 mA maximum consumption; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e27.9 mm (1100 mils), from approximately 1.3 mm to 29.2 mm (50 to 1150 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e394 mV\/mm (10 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.74 mm (+\/-29 mils) within 0 degC to +45 degC range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpringLoc terminal strip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupported Field Wiring Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eProximitor voltage output signal (dynamic and DC gap)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon circuit return reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e-VT\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDIN rail mounting utilizes the integrated DIN pad designed for a standard 35 mm DIN rail. Allow an additional 3.05 mm of clearance to remove the module from the rail.\u003c\/li\u003e\n  \u003cli\u003eGround the shield of the extension cable at the Proximitor Sensor housing. Do not ground the coaxial shield at any other point to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003eUse recommended three-conductor shielded triad field cable (18 AWG or similar) for runs from the Proximitor Sensor to the monitor rack.\u003c\/li\u003e\n  \u003cli\u003eMaintain minimum target size requirements of 102 mm (4.0 inches) flat target diameter when verifying system calibration.\u003c\/li\u003e\n  \u003cli\u003eCalibrate the probe gap using the physical movement of a sliding bracket or spindle micrometer prior to locking the case threads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eATEX\/IECEx: Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc, Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc (Option 05)\u003c\/li\u003e\n  \u003cli\u003eCSA\/CNRTLus: Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n  \u003cli\u003eEuropean CE Mark: Compliant with EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eElectromagnetic Compatibility Standards: EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n  \u003cli\u003eChina RoHS: 15-year Environment Friendly Use Period (EFUP)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666570998123,"sku":"330878-91-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330878-91-05-proximitor-sensor-p4h5thnndfr_6157fe43-0bed-4238-a4c9-e944da3ab6b9.jpg?v=1765440837"},{"product_id":"bently-nevada-330878-90-05-3300-xl-50-mm-proximitor-sensor","title":"Bently Nevada 330878-90-05 3300 XL 50 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 90 (9.0 meters system length, panel mount) and Option 05 (Multiple Approvals) specify this \u003cstrong\u003e3300 XL 50 mm Proximitor Sensor\u003c\/strong\u003e configuration — \u003cstrong\u003e330878-90-05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWhile DIN mount configurations (Option 91) and 5.0-meter systems (Option 50 or 51) are available, this panel-mount, 9.0-meter system matches 330876 probes and 330877 extension cables for longer transmission distances. The Multiple Approvals selection allows installation in designated hazardous environments where compliance is required. The sensor utilizes advanced eddy-current technology to process displacement signals from a 50 mm probe, rendering it highly effective for differential expansion (DE) or rotor expansion (RX) measurements on steam turbine generators.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Length:\u003c\/strong\u003e Configured for a 9.0 m (29.5 ft) system length, providing compatibility with corresponding 50 mm probes and extension cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style:\u003c\/strong\u003e Panel-mount physical design for secure attachment to mounting plates or internal enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgency Approvals:\u003c\/strong\u003e Option 05 designates multiple global hazardous area certifications, including CSA, ATEX, and IECEx approvals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Built-in SpringLoc terminal strips provide fast, highly robust field connections without specialized tools.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRFI\/EMI Immunity:\u003c\/strong\u003e Robust design elements shield signal integrity against nearby high-frequency radio interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDifferential expansion (DE) measurement on utility steam turbine generators.\u003c\/li\u003e\n  \u003cli\u003eRotor expansion (RX) monitoring to track thermal growth differentials.\u003c\/li\u003e\n  \u003cli\u003eAxial position and displacement tracking in heavy industrial rotating machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-90-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, panel mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-90-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e27.9 mm (1100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBegins at 1.3 mm (50 mils) to 29.2 mm (1150 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e394 mV\/mm (10 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.74 mm (+\/-29 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Sensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one 3300 XL 50 mm proximity probe and extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eField Wiring Terminal Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Field Wire Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-conductor shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n      \u003cth\u003eWiring Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 to -26 Vdc)\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Ground reference\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDynamic analog output voltage signal\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the Proximitor Sensor on a clean, flat surface using the standard panel-mount configuration holes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Ensure the field wiring shield is connected to the monitor common ground and insulated at the Proximitor end to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Connection:\u003c\/strong\u003e Depress the SpringLoc lever, insert the stripped conductor (0.2 to 1.5 mm2), and release to secure. No special tools are needed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Cable Bend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 in) for coaxial and triaxial system cables to prevent signal loss or conductor damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCertification Body \/ Standard\u003c\/th\u003e\n      \u003cth\u003eApproval Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCE Mark\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eComplies with European Community Directive 2014\/30\/EU (EMC) and RoHS Directive 2011\/65\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Standards\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions) for Industrial Environments\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNorth American Approvals (cNRTLus)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClass I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T5...T1 Ga, Ex ia IIIC T90 degC...T280 degC Dc; Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaritime\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2019 Rules for Conditions of Classification\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572603755,"sku":"330878-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330878-90-05-proximitor-sensor-gwpqylptnek_75a84746-c19c-440e-9220-efa4c992eccd.jpg?v=1765440866"},{"product_id":"bently-nevada-330180-x1-05-mod-145004-47-3300-xl-5mm-8mm-proximitor-sensor","title":"Bently Nevada 330180-X1-05 MOD 145004-47 3300 XL 5mm\/8mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330180-X1-05\u003c\/strong\u003e with modification code \u003cstrong\u003e145004-47\u003c\/strong\u003e is a proximity sensor conditioning device engineered for non-contact vibration, position, and displacement measurements. This \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e is calibrated to accommodate alternative target materials other than standard 4140 steel, generating a linear voltage output proportional to the gap between the probe tip and the target surface. The device serves as a primary component within proximity probe systems, interfacing directly with machinery monitoring platforms to track shaft dynamics and position in critical rotating machinery applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecialized target material recalibration under modification 145004-47\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy conversion of eddy-current probe impedance variation to stable DC voltage\u003c\/li\u003e\n\u003cli\u003eInteroperability with specific 5mm and 8mm proximity probe configurations\u003c\/li\u003e\n\u003cli\u003eRobust mechanical housing designed for harsh industrial deployment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact shaft vibration and displacement monitoring\u003c\/li\u003e\n\u003cli\u003eThrust position measurement in critical rotating machinery\u003c\/li\u003e\n\u003cli\u003eMachinery protection and condition monitoring networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e 330180 (Proximitor Sensor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModification Code:\u003c\/strong\u003e 145004-47 (Recalibration to Specific Target Material)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e 3300 XL 5mm\/8mm 9m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e330180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModification Code\u003c\/td\u003e\n\u003ctd\u003e145004-47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e10 to 90 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Zero\u003c\/td\u003e\n\u003ctd\u003e-3.0 Vdc @ 20 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Configuration\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5mm\/8mm 9m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure a dedicated electrical ground to prevent high-frequency noise from corrupting the sensor signal output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Ensure all field wiring cables are properly shielded with the drain wires terminated at the monitor rack side only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Adjustment:\u003c\/strong\u003e Calibrate the physical probe gap using a digital voltmeter to verify the electrical zero setting of -3.0 Vdc at a 20-mil distance before securing the probe.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572898667,"sku":"330180-X1-05 MOD：145004-47","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145004-47-proximitor-sensor-odczbzodjj0_9295702c-f8d3-4344-b88e-df2cd5d1db27.jpg?v=1765440870"},{"product_id":"bently-nevada-330500-00-02-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-00-02 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330500-00-02\u003c\/strong\u003e Velomitor Piezo-velocity Sensor is a specialized piezoelectric transducer designed for absolute vibration measurement of bearing housings, casings, and machine structures. This configuration features Option 00 (no mounting thread adapter) and Option 02 (ATEX European hazardous area approval). By utilizing a solid-state design with embedded electronics, this sensor eliminates moving parts, reducing mechanical wear and ensuring reliable performance across various mounting orientations including vertical, horizontal, or angled installation.\u003c\/p\u003e\n\n\u003cp\u003eThis \u003cstrong\u003e330500 Velomitor Piezo-velocity Sensor\u003c\/strong\u003e provides consistent velocity output to monitor common machinery malfunctions such as unbalance and misalignment. It is designed to be installed directly onto the machine casing or bearing housing. The unit features a hermetically sealed 316L stainless steel housing, ensuring structural integrity in harsh industrial environments. When integrating this sensor, ensure proper installation to maintain the specified amplitude and frequency response, avoiding the introduction of false signals that do not accurately represent machine vibration.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 00 mounting configuration (No adapter supplied)\u003c\/li\u003e\n\u003cli\u003eOption 02 hazardous area approval (ATEX European)\u003c\/li\u003e\n\u003cli\u003e316L stainless steel case material for corrosion resistance\u003c\/li\u003e\n\u003cli\u003eSolid-state design with no moving parts for extended operational life\u003c\/li\u003e\n\u003cli\u003eHermetically sealed 2-pin MIL-C-5015 connector\u003c\/li\u003e\n\u003cli\u003eVelocity output range up to 1270 mm\/s (50 in\/s) peak\u003c\/li\u003e\n\u003cli\u003eFrequency response: 4.5 Hz to 5 kHz (±3.0 dB)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBearing housing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eCasing and structural vibration analysis\u003c\/li\u003e\n\u003cli\u003eGeneral rotating machinery protection (pumps, fans, motors, compressors)\u003c\/li\u003e\n\u003cli\u003eApplications requiring ATEX hazardous area compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-00-02\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread Adaptor\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX (European)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330500-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (±3.0 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-55 degC to 121 degC (-67 degF to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e32-46 kg cm (24-40 in-lb) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.142 kg (142 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e63.2 mm (height) x 25.3 mm (diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the sensor securely to the machine casing using the appropriate thread interface. Ensure the transducer is installed on a flat, rigid surface to maintain accurate frequency response. The sensor case is isolated from the internal circuitry; ensure the cable shielding is properly grounded at the monitor end to minimize electrical noise interference. For hazardous area installations (Option 02), refer to the installation drawing provided in the product datasheet to comply with ATEX safety requirements.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX Directive 2014\/34\/EU (Option 02)\u003c\/li\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eChina RoHS\u003c\/li\u003e\n\u003cli\u003eFCC Part 15\u003c\/li\u003e\n\u003cli\u003eABS Marine Vessels, Offshore Units and Structures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666607305067,"sku":"330500-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-00-02-velomitor-piezo-velocity-sensor-acinbs4c014_f59355c2-9769-455c-83e9-d51a77576ab3.jpg?v=1765444093"},{"product_id":"bently-nevada-330500-04-01-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-04-01 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330500-04-01 Velomitor Piezo-velocity Sensor\u003c\/strong\u003e is a specialized piezoelectric accelerometer designed for measuring absolute casing, housing, or structural vibration. This configuration features a \u003cstrong\u003e1\/4-20 UNC mounting thread (Option 04)\u003c\/strong\u003e and \u003cstrong\u003eCSA\/US\/C agency approvals (Option 01)\u003c\/strong\u003e. The sensor utilizes a solid-state, integrated design with no moving parts, allowing for flexible mounting orientations including vertical, horizontal, and angled positions without risk of mechanical wear or degradation.\u003c\/p\u003e\n\n\u003cp\u003eUsed extensively in industrial machinery protection, the 330500 provides a velocity-based output signal representing absolute vibration. Unlike traditional moving-coil sensors, this piezo-velocity technology is immune to the mechanical limitations associated with internal wear, ensuring long-term operational stability in demanding monitoring environments. It is intended for mounting directly to bearing housings or machine casings to capture vibration data necessary for identifying common machinery malfunctions such as unbalance and misalignment.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1\/4-20 UNC mounting thread adapter (Option 04)\u003c\/li\u003e\n\u003cli\u003eCSA\/US\/C hazardous area agency approvals (Option 01)\u003c\/li\u003e\n\u003cli\u003eSolid-state design with no moving parts to prevent mechanical wear\u003c\/li\u003e\n\u003cli\u003e316L stainless steel, hermetically sealed housing for durability\u003c\/li\u003e\n\u003cli\u003e2-pin Mil-C-5015 connector interface\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Bently Nevada monitoring systems\u003c\/li\u003e\n\u003cli\u003eCapable of vertical, horizontal, or angled mounting orientations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower generation equipment vibration monitoring\u003c\/li\u003e\n\u003cli\u003eOil and gas rotating machinery protection\u003c\/li\u003e\n\u003cli\u003ePetrochemical and industrial pump\/compressor casing monitoring\u003c\/li\u003e\n\u003cli\u003eGeneral structural and bearing housing vibration analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-04-01\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e1\/4-20 UNC mounting adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/US\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330500-04-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (+\/- 3.0 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to 121 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.142 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin Mil-C-5015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e32-46 kg cm (24-40 in-lb) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA\/US\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\/US\/C (Option 01)\u003c\/li\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eFCC Part 15 compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666609172843,"sku":"330500-04-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-04-01-velomitor-piezo-velocity-sensor-xd2y1r4vzfw_5dcb9b7f-7fea-4fec-a553-b518087f97e6.jpg?v=1765444118"},{"product_id":"bently-nevada-330780-12-00-3300-xl-11-mm-proximitor-sensor-1","title":"Bently Nevada 330780-12-00 3300 XL 11 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003eBently Nevada 330780-12-00\u003c\/strong\u003e 3300 XL Proximitor Sensor is a non-contact eddy current displacement transducer designed for precise vibration and position monitoring of rotating machinery. This specific configuration, indicated by option -12, provides a full-scale range of 0.040 inches (1.0 mm) and is optimized for use with Bently Nevada 3300 XL 11 mm proximity probes. It is suitable for applications requiring high accuracy and reliability in challenging industrial environments.\n\nThis Proximitor sensor is a key component of the 3300 XL Proximity Transducer System, which also includes an 11 mm proximity probe and an extension cable. The -00 option signifies no specific agency approvals, making it suitable for general-purpose industrial installations where hazardous area certifications are not required. The 3300 XL series is known for its improved performance over older designs, offering enhanced immunity to radio frequency interference (RFI) and transient protection.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact eddy current measurement principle for vibration and position.\u003c\/li\u003e\n\u003cli\u003eConfigured with Option -12 for 0.040 in (1.0 mm) full-scale range, compatible with 3300 XL 11 mm probes.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy and linearity for critical machinery monitoring.\u003c\/li\u003e\n\u003cli\u003eImproved RFI\/EMI immunity meeting CE mark requirements.\u003c\/li\u003e\n\u003cli\u003eRobust design for reliable operation in industrial environments.\u003c\/li\u003e\n\u003cli\u003eOffers high transient overvoltage protection.\u003c\/li\u003e\n\u003cli\u003eStandard configuration, designated by -00, for non-hazardous areas.\u003c\/li\u003e\n\u003cli\u003eTypically mounted in a panel, DIN rail, or custom enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAxial position (thrust) measurement on turbines, compressors, and pumps.\u003c\/li\u003e\n\u003cli\u003eRadial vibration monitoring on large rotating machinery shafts.\u003c\/li\u003e\n\u003cli\u003eDifferential expansion measurements.\u003c\/li\u003e\n\u003cli\u003eRod drop monitoring on reciprocating compressors.\u003c\/li\u003e\n\u003cli\u003eMonitoring shaft position relative to bearing clearances.\u003c\/li\u003e\n\u003cli\u003eMachinery protection and condition monitoring systems in power generation, oil and gas, petrochemical, and manufacturing industries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330780-12-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Proximitor Sensor\u003c\/td\u003e\n\u003ctd\u003e330780\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Full-Scale Range\/Probe Compatibility\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e0.040 in (1.0 mm) Full-Scale Range, for 11 mm Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Agency Approval (Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n\u003ctd\u003e330780-12-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximity Probes, 3300 XL Extension Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc to -30 Vdc (typically -24 Vdc nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum, typical (without alarm option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-2 Vdc to -22 Vdc (typical linear range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range (FSR)\u003c\/td\u003e\n\u003ctd\u003e0.040 in (1.0 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-6% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e+\/-0.0001 in (+\/-0.0025 mm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 10 kHz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range (Operating)\u003c\/td\u003e\n\u003ctd\u003e-34 degC to +71 degC (-30 degF to +160 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range (Storage)\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel or DIN rail mount (with optional mounting clip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\nProper installation is crucial for the optimal performance of the 3300 XL Proximitor Sensor. Ensure the sensor is securely mounted on a flat surface or DIN rail in a vibration-free area. All cables, including the probe and extension cables, must be routed away from sources of electrical noise and high-voltage lines to prevent interference. Grounding practices must adhere to Bently Nevada recommendations to ensure proper system performance and safety. The probe gap voltage should be set according to specific machinery requirements for accurate measurement and to utilize the full linear range of the Proximitor.\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\nThe 330780-12-00, specified with Option -00, does not include specific hazardous area agency approvals such as ATEX, IECEx, or CSA. It complies with general CE mark requirements for electromagnetic compatibility (EMC) and low voltage directive (LVD) for use in industrial environments.","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666609533291,"sku":"330901-00-90-10-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-90-10-01-05-3300-nsv-proximity-probes-0fsiu0gc41f_d5cb9fed-5442-47b8-bf87-ea592822f596.jpg?v=1765444120"},{"product_id":"bently-nevada-330850-50-00-3300-xl-25-mm-proximitor-sensor","title":"Bently Nevada 330850-50-00 3300 XL 25 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330850-50-00\u003c\/strong\u003e specifies a 3300 XL 25 mm Proximitor Sensor configured with a 5.0-metre system length, flat-surface panel mounting, and no agency approvals. This sensor functions as an analog signal conditioner within a 3300 XL 25 mm Proximity Transducer System, generating a continuous voltage output directly proportional to the distance between a paired 25 mm probe tip and a target material.\u003c\/p\u003e\n\u003cp\u003eUnlike DIN-mount configurations or variants built with intrinsic safety approvals, this unit is designed specifically for general-purpose, non-hazardous area panels. It supports large-target displacement monitoring applications, such as steam turbine thrust position and differential expansion. The system is designed to provide stable performance over extended temperature ranges when paired with 330851 probes and 330854 extension cables.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystem length of 5.0 metres (Option 50) is matched for calibration with standard five-meter probe and cable assemblies.\u003c\/li\u003e\n\u003cli\u003ePanel-mount mounting style (Option 50) comes complete with four 6-32 thread-forming mounting screws.\u003c\/li\u003e\n\u003cli\u003eNo agency approvals (Option 00) simplifies installation in standard general-purpose plant areas.\u003c\/li\u003e\n\u003cli\u003eSpringLoc terminal strips provide reliable, direct field wiring connections without requiring specialized crimping or landing tools.\u003c\/li\u003e\n\u003cli\u003eA380 aluminum housing is constructed to resist environmental corrosion and shield inner circuitry from electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eActive voltage regulation maintains high stability with less than 2 mV output drift per volt of supply input fluctuation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine thrust position monitoring\u003c\/li\u003e\n\u003cli\u003eDifferential expansion measurements on large utility turbine shafts\u003c\/li\u003e\n\u003cli\u003eReciprocating compressor rod-drop and displacement tracking\u003c\/li\u003e\n\u003cli\u003eLarge-diameter rotor mechanical position and vibration analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330850-50-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Total Length and Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet) system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e330850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330850-50-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n\u003ctd\u003eAccepts one 3300 XL 25 mm proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e12.7 mm (500 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range Limits\u003c\/td\u003e\n\u003ctd\u003eBegins at approximately 0.63 mm (25 mils) up to 13.33 mm (525 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Scale Factor (ASF)\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.31 mm (+\/-12 mils) at standard operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Supply Requirement\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Voltage\u003c\/td\u003e\n\u003ctd\u003eApproximately -1.5 Vdc to -11.5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 2.7 kHz (+0, -3 dB typical) with up to 305 metres of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Cable Support\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG); three-conductor shielded triad recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wiring Distance\u003c\/td\u003e\n\u003ctd\u003e305 metres (1000 feet) to monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Limit\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Mass\u003c\/td\u003e\n\u003ctd\u003e255 g (9.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Designation\u003c\/th\u003e\n\u003cth\u003eDescription and Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoaxial Connector\u003c\/td\u003e\n\u003ctd\u003eInputs from the paired 3300 XL 25 mm proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSystem Common \/ return path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eAnalog linear output voltage signal (-1.5 Vdc to -11.5 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT\u003c\/td\u003e\n\u003ctd\u003ePower supply input terminal (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the Proximitor on a flat metal panel or enclosure surface using the four supplied 6-32 thread-forming panel screws. Strip external field wire insulation to reveal conductors from 0.2 to 1.5 mm2 (16 to 24 AWG) and insert directly into the SpringLoc terminal blocks. Thread coaxial connections finger-tight to ensure robust contact, not exceeding the maximum recommended torque limit of 0.565 Nm (5 in-lb). Maintain environmental conditions within the operating temperature limits and protect coaxial connectors with self-fusing silicone tape if moisture exposure is possible.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666610450795,"sku":"330850-50-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330850-50-00-3300-xl-25-mm-proximitor-sensor-m4rs1uhxyrc_80cfc98f-bc8c-4e7a-85d7-c44ac2edcd83.jpg?v=1765444134"},{"product_id":"bently-nevada-330500-03-04-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-03-04 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e330500-03-04\u003c\/strong\u003e Velomitor Piezo-velocity Sensor is an industrial-grade, solid-state transducer designed to monitor absolute casing, bearing housing, and structural vibration. This configuration features a 1\/4-28 UNF mounting thread (Option 03) and carries multiple hazardous area approvals, including CSA and ATEX (Option 04). Engineered as a specialized piezoelectric accelerometer with integrated electronics, this sensor contains no moving parts, preventing mechanical wear and degradation while allowing for flexible mounting orientations including vertical, horizontal, and radial.\n\nThis \u003cstrong\u003eVelomitor Piezo-velocity Sensor\u003c\/strong\u003e provides consistent performance for critical machinery protection, particularly when measuring rotor vibration transmitted to the machine casing. It is housed in a hermetically sealed 316L stainless steel case to ensure reliability in challenging industrial environments. Proper installation on the bearing housing or casing is essential, as incorrect mounting may degrade frequency response or introduce signal interference.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated solid-state electronics with no moving parts for reduced mechanical wear\u003c\/li\u003e\n\u003cli\u003e316L stainless steel, hermetically-sealed case for environmental durability\u003c\/li\u003e\n\u003cli\u003e1\/4-28 UNF mounting thread adapter (Option 03)\u003c\/li\u003e\n\u003cli\u003eMultiple agency approvals including CSA and ATEX (Option 04)\u003c\/li\u003e\n\u003cli\u003eCase-isolated grounding to minimize electrical noise interference\u003c\/li\u003e\n\u003cli\u003eOperates across a wide temperature range from -55 Celsius to 121 Celsius\u003c\/li\u003e\n\u003cli\u003eCompatible with standard 2-pin MIL-C-5015 connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe 330500 Velomitor sensor is used in heavy industry to measure machine casing and structural vibration. Typical scenarios include:\n\u003cul\u003e\n\u003cli\u003ePower generation equipment and turbines\u003c\/li\u003e\n\u003cli\u003eOil and gas compressors and pumps\u003c\/li\u003e\n\u003cli\u003ePetrochemical and industrial rotating machinery\u003c\/li\u003e\n\u003cli\u003eWater treatment and mining infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-03-04\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread Adapter\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals (CSA, ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330500-03-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (+\/- 3.0 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 Celsius to 121 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eCase isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Survivability\u003c\/td\u003e\n\u003ctd\u003e5,000 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.142 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the sensor is mounted directly to the machine casing or bearing housing using the specified mounting adapter.\u003c\/li\u003e\n\u003cli\u003eObserve the maximum mounting torque of 32-46 kg cm (24-40 in-lb).\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling to maintain signal integrity, particularly in areas with high electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eWhen integrating to measure displacement, be aware that electrical noise may be amplified; prioritize velocity monitoring for optimal performance.\u003c\/li\u003e\n\u003cli\u003eEnsure installation in hazardous areas complies with the specific requirements of the approved entity parameters (CSA\/ATEX).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666612154731,"sku":"330500-03-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-03-04-piezo-velocity-sensor-nt21fq3dy5r_bf615f53-840d-432a-8c09-a84fcf065d6f.jpg?v=1765444153"},{"product_id":"bently-nevada-330180-52-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-52-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330180-52-05\u003c\/strong\u003e \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e is a critical component of the 3300 XL 8 mm proximity transducer system, configured with Option 52 for total system length and Option 05 for agency approval. This sensor facilitates non-contact displacement measurements for shaft vibration and axial position on critical rotating machinery, interfacing seamlessly with 3300 XL 8 mm probes and extension cables.\u003c\/p\u003e\n\n\u003cp\u003eThe unit processes the radio frequency signal from the proximity probe, converting it into a proportional voltage output suitable for monitoring and protection systems. The 3300 XL design ensures compatibility with existing 3300 series installations while providing improved interchangeability and signal integrity. The -05 agency approval option confirms the unit is suitable for use in hazardous environments requiring CSA, ATEX, and IECEx certifications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for 3300 XL 8 mm proximity probe systems\u003c\/li\u003e\n\u003cli\u003eOption 52: Configured for specific system length requirements\u003c\/li\u003e\n\u003cli\u003eOption 05: Compliant with CSA, ATEX, and IECEx hazardous area certifications\u003c\/li\u003e\n\u003cli\u003eNear-linear output signal for accurate displacement monitoring\u003c\/li\u003e\n\u003cli\u003eRugged housing for industrial mounting in harsh conditions\u003c\/li\u003e\n\u003cli\u003eInterchangeable with other 3300 XL components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine shaft vibration monitoring\u003c\/li\u003e\n\u003cli\u003eCompressor rotor position sensing\u003c\/li\u003e\n\u003cli\u003eCritical rotating machinery protection\u003c\/li\u003e\n\u003cli\u003eFluid film bearing health assessment\u003c\/li\u003e\n\u003cli\u003eIndustrial power generation and petrochemical process control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-52-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Total System Length\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003eSee PDF Ordering Guide for specific system length matching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330180-52-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx (Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the Proximitor sensor is installed in a protective, non-hazardous enclosure unless local hazardous area regulations specify otherwise. Mount the unit on a grounded DIN rail or panel. Maintain proper shielding and grounding practices to prevent electromagnetic interference. Ensure that cable connections between the probe, extension cable, and Proximitor are clean and tightened to the specified torque to prevent signal degradation.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis unit meets CSA, ATEX, and IECEx hazardous area requirements as specified by Option 05. Always verify the specific certification labels on the device against the intended application environment.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666617790827,"sku":"330180-52-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-52-05-3300-xl-proximitor-sensor-5cuhhpy221e_22ec9df1-fcd4-4ee8-b575-5aba4c68cc2e.jpg?v=1765444217"},{"product_id":"bently-nevada-330180-10-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-10-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-10-05\u003c\/strong\u003e specifies a 3300 XL Proximitor Sensor configured for a 1.0 m system length and designed for panel-mount applications. This sensor conditions and drives the proximity probe signal in non-contact eddy-current measurement chains, converting raw probe output into a linear voltage displacement signal. The integration of Option 10 dictates that the sensor is calibrated for a 1.0 m total system length (typically used in direct-probe or short-range configurations without an extension cable) and comes with a 4-hole panel-mount base.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration includes Option 05 agency approvals, qualifying the module for use under CSA, ATEX, and IECEx hazardous area certifications. In contrast to standard non-approved configurations (Option 00) or DIN-rail mounted variants (such as Option 11), the panel-mount base of the 330180-10-05 maintains the classic footprint compatible with older Proximitor styles. It features built-in electrical isolation, removing any necessity for separate isolator plates in high-density installations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 10 defines a 1.0 m (3.3 ft) system calibration length, configured specifically for panel-mount installations with a 4-hole footprint.\u003c\/li\u003e\n\u003cli\u003eOption 05 designates CSA, ATEX, and IECEx hazardous area certification, enabling installation under intrinsically safe and non-incendive parameters.\u003c\/li\u003e\n\u003cli\u003eSpringLoc terminal strip provides robust field-wiring connections without the need for special installation tools.\u003c\/li\u003e\n\u003cli\u003eA308 aluminum housing construction offers resistance to radio frequency interference (RFI) and electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eCoaxial ClickLoc connector interface secures the sensor-to-cable attachment for structural stability.\u003c\/li\u003e\n\u003cli\u003e-17.5 Vdc to -26 Vdc power supply input compatibility supports connection to 3500 monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical heavy-industry machinery monitoring applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and axial position measurement on high-speed turbines and compressors.\u003c\/li\u003e\n\u003cli\u003eShaft eccentricity and thermal expansion monitoring on utility generators and electric motors.\u003c\/li\u003e\n\u003cli\u003eGeneral rotating machinery protection systems requiring ATEX\/IECEx certified intrinsically safe sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330180-10-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Total Length and Mounting Option\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet) system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330180-10-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel mount (4-hole footprint)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e-1 Vdc to -17 Vdc (displacement over 2.0 mm linear range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA308 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.246 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.3 mm x 61.0 mm x 50.8 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eLess than 3% ASF change in 93% humidity up to 56 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Label\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT\u003c\/td\u003e\n\u003ctd\u003eVoltage Supply Input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon\/System Ground Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eLinear Analog Output Signal (-1 to -17 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the Proximitor sensor directly to a flat panel using the standard 4-hole mounting footprint.\u003c\/li\u003e\n\u003cli\u003eEnsure proper electrical isolation by utilizing the integrated isolation base, preventing ground loops.\u003c\/li\u003e\n\u003cli\u003eUse a 3-conductor shielded triad cable (0.2 to 1.5 mm2 or 16 to 24 AWG) for field wiring connections to the monitor.\u003c\/li\u003e\n\u003cli\u003eStrip field wires to the recommended length before inserting into the SpringLoc terminal strip.\u003c\/li\u003e\n\u003cli\u003eEnsure the coaxial connection is finger-tight (0.565 Nm maximum torque) to prevent damage to gold contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA (Class I, Division 2, Groups A, B, C, D)\u003c\/li\u003e\n\u003cli\u003eATEX (Ex ia IIC T4\/T5 Ga, Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc)\u003c\/li\u003e\n\u003cli\u003eIECEx (Ex ia IIC T4\/T5 Ga, Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc)\u003c\/li\u003e\n\u003cli\u003eCE Mark\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666621165931,"sku":"330180-10-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-10-05-3300-xl-proximitor-sensor-wv345e10lph_32892a72-a270-4925-8e24-fb914165da2e.jpg?v=1765444259"},{"product_id":"bently-nevada-330500-00-00-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-00-00 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e330500-00-00 Velomitor Piezo-velocity Sensor\u003c\/strong\u003e is a specialized piezoelectric accelerometer designed for measuring absolute casing, bearing housing, and structural vibration. This configuration includes Option 00 for mounting (no adapter included) and Option 00 for agency approval (not required), providing a versatile solution for standard machinery monitoring applications.\n\nThis sensor integrates solid-state electronics, eliminating moving parts to prevent mechanical wear and degradation. It is suitable for horizontal, vertical, and angular mounting orientations. When used in conjunction with Bently Nevada monitoring systems, it provides precise velocity measurements for identifying common machinery malfunctions such as unbalance and misalignment.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated solid-state electronics design with no moving parts\u003c\/li\u003e\n\u003cli\u003eStandard sensitivity of 3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5 percent\u003c\/li\u003e\n\u003cli\u003eBroadband frequency response from 4.5 Hz to 5 kHz (+\/- 3.0 dB)\u003c\/li\u003e\n\u003cli\u003eHermetically-sealed 316L stainless steel housing for environmental protection\u003c\/li\u003e\n\u003cli\u003eCase-isolated grounding configuration\u003c\/li\u003e\n\u003cli\u003eSupports long cable runs up to 305 m (1,000 ft) without signal degradation\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range of -55 degC to 121 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe 330500 Velomitor sensor is used in critical rotating machinery protection for industries such as:\n\u003cul\u003e\n\u003cli\u003ePower Generation (Turbines, Generators)\u003c\/li\u003e\n\u003cli\u003eOil and Gas (Pumps, Compressors)\u003c\/li\u003e\n\u003cli\u003ePetrochemical and Refining\u003c\/li\u003e\n\u003cli\u003eWater and Wastewater Treatment\u003c\/li\u003e\n\u003cli\u003eGeneral Industrial Rotating Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-00-00\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread Adaptor\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330500-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (+\/- 3.0 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude Linearity\u003c\/td\u003e\n\u003ctd\u003e+\/- 2 percent to 152 mm\/s (6 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounted Resonant Frequency\u003c\/td\u003e\n\u003ctd\u003eGreater than 12 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015, hermetically-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to 121 degC (-67 degF to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.142 kg (5.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.3 mm diameter x 63.2 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eCase isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the sensor is installed directly on the bearing housing or machine casing to maintain accurate frequency response.\u003c\/li\u003e\n\u003cli\u003eAvoid mounting in locations where the transducer amplitude might be decreased or false signals are generated due to improper contact.\u003c\/li\u003e\n\u003cli\u003eUse appropriate torque (32-46 kg cm or 24-40 in-lb max) when mounting to prevent damage to the housing or threads.\u003c\/li\u003e\n\u003cli\u003eCable runs should be secured and shielded to maintain signal integrity over long distances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eChina RoHS (EFUP 15 years)\u003c\/li\u003e\n\u003cli\u003eABS Marine Vessels compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666621722987,"sku":"330500-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-00-00-velomitor-piezo-velocity-sensor-cmaahahkqvn_3a4d51d4-78c2-4b74-9aae-3c329f1d288e.jpg?v=1765444269"},{"product_id":"bently-nevada-330780-50-05-3300-xl-11-mm-proximitor-sensor","title":"Bently Nevada 330780-50-05 3300 XL 11 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330780-50-05\u003c\/strong\u003e is a 3300 XL 11 mm Proximitor Sensor configured for a 5.0 meter system length with panel mounting and multiple agency approvals (Option 05). This component serves as the central signal processing unit in the Bently Nevada 3300 XL 11 mm Proximity Transducer System, facilitating precise non-contact displacement and vibration measurements.\u003c\/p\u003e\n\u003cp\u003eThe Proximitor sensor provides a standardized 3.94 V per mm (100 mV per mil) output, maintaining system integrity across varying cable lengths. Designed to replace legacy 7200-series 11 mm and 14 mm transducer systems, this unit supports demanding industrial applications such as axial position, radial vibration, and Keyphasor phase reference measurements on fluid film bearing machinery. It features robust SpringLoc terminal strips for efficient field wiring and advanced RFI\/EMI immunity, ensuring consistent performance without special mounting precautions.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e5.0 meter system length configuration\u003c\/li\u003e\n\u003cli\u003ePanel mount mechanical design\u003c\/li\u003e\n\u003cli\u003eOption 05 multiple agency approvals\u003c\/li\u003e\n\u003cli\u003e3.94 V per mm (100 mV per mil) output\u003c\/li\u003e\n\u003cli\u003eAdvanced RFI\/EMI immunity for reliable signal transmission\u003c\/li\u003e\n\u003cli\u003eSpringLoc terminal strips for rapid field connections\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 XL 11 mm proximity probes and extension cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine ramp differential expansion\u003c\/li\u003e\n\u003cli\u003eReciprocating compressor rod position and rod drop\u003c\/li\u003e\n\u003cli\u003eCritical machinery axial (thrust) position\u003c\/li\u003e\n\u003cli\u003eRadial shaft vibration\u003c\/li\u003e\n\u003cli\u003eTachometer and zero speed measurement\u003c\/li\u003e\n\u003cli\u003eKeyphasor phase reference signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330780-50-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Total Length and Mounting\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 meter system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330780-50-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 meter (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003ePanel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e3.94 V per mm (100 mV per mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e4.0 mm (160 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 8 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 Celsius to +45 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals (Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the extension cable length and the probe length, when added together, equal the Proximitor Sensor total system length. The sensor is designed for panel mounting. Use appropriate shielding for field wiring and ensure all connections are secure via the SpringLoc terminal strips. For hazardous area installations, adhere to the specific Bently Nevada drawings referenced in the system datasheet, ensuring the installation meets required IP54 protection ratings if applicable.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666622935403,"sku":"330780-50-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330780-50-05-3300-xl-11-mm-proximitor-sensor-1flxncf00v1_7af3e0f3-0c44-430a-8126-be508a623c58.jpg?v=1765444282"},{"product_id":"bently-nevada-330780-91-05-3300-xl-11-mm-proximitor-sensor","title":"Bently Nevada 330780-91-05 3300 XL 11 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 91 (9.0 meters system length, DIN-rail mount) and Option 05 (Multiple Approvals) specify this 3300 XL 11 mm Proximitor Sensor configuration — \u003cstrong\u003e330780-91-05\u003c\/strong\u003e. As a primary instrument in 3300 XL 11 mm proximity transducer systems, this sensor conditions the non-contact, eddy-current signal from the paired probe and extension cable, providing a continuous analog output voltage directly proportional to the physical gap between the probe tip and the target material. The 9.0-meter calibration matches the combined length of the probe and extension cable, maintaining measurement accuracy across the complete 4.0 mm (160 mils) linear range.\u003c\/p\u003e\n\n\u003cp\u003eThis specific variant features a DIN-rail mounting base to allow high-density installation within industrial enclosures, contrasting with panel-mounted siblings (such as Option 90). The integrated SpringLoc terminal strips facilitate secure field wiring without special tooling. With built-in electromagnetic compatibility designed to meet CE requirements, this device offers high immunity to radio frequency interference (RFI) without requiring specialized shielded housings. The Option 05 certification package certifies the unit for global hazardous area installations under CSA, ATEX, and IECEx approvals.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 91 provides 9.0 meters (29.5 feet) system length calibration, matching the combined probe and cable total length.\u003c\/li\u003e\n  \u003cli\u003eIntegrated DIN-rail mounting hardware enables compact, direct installation within industrial enclosures.\u003c\/li\u003e\n  \u003cli\u003eOption 05 Multiple Approvals package offers certified operation for hazardous environments under CSA, ATEX, and IECEx standards.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal strips require no special tools for field wiring, offering secure and vibration-resistant wire retention.\u003c\/li\u003e\n  \u003cli\u003eHigh RF interference immunity minimizes output noise from nearby radio frequency sources.\u003c\/li\u003e\n  \u003cli\u003eNative analog output delivers 3.94 V\/mm (100 mV\/mil) incremental scale factor (ISF) over a 4.0 mm (160 mils) linear range.\u003c\/li\u003e\n  \u003cli\u003eRobust A380 aluminum housing provides physical protection and structural durability in heavy industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and position monitoring on large industrial steam\/gas turbines and compressors.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position measurement for critical rotating machinery shafts.\u003c\/li\u003e\n  \u003cli\u003eKeyphasor and phase reference applications on 11 mm probe transducer chains.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection systems in hazardous area petrochemical and power generation facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330780-91-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Total Length and Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e91\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple approvals (CSA, ATEX, IECEx, NEPSI)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330780-91-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCalibration Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) total system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN-rail mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), begins at approx. 0.5 mm (20 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10% (under standard calibration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (no barriers), -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV output voltage change per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpringLoc terminal strips, accepts 0.2 to 1.5 mm2 (16 to 24 AWG) field wire\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz: +0, -3 dB typical with up to 305 meters of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e89.4 mm x 70.8 mm x 31.7 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe sensor features a 3-pin SpringLoc terminal strip for reliable field connections without the need for special tools:\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInput supply voltage (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSignal common return\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog voltage output signal (3.94 V\/mm or 100 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\nEnsure correct mechanical alignment and electrical parameters when installing the proximity transducer system:\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the Proximitor sensor onto standard 35 mm DIN rail using the integrated DIN mount option (Option 91). Ensure an additional 3.05 mm (0.120 in) clearance is provided above and below the mounting area for easy DIN rail removal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Length Matching:\u003c\/strong\u003e This Proximitor is calibrated specifically for a 9.0-meter total system length. The combined length of the connected 3300 XL 11 mm probe and extension cable must equal 9.0 meters to maintain calibrated sensor linearity and prevent measurement errors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Wiring Connections:\u003c\/strong\u003e Utilize 3-conductor shielded triad cable (0.2 to 1.5 mm2 or 16 to 24 AWG field wire) to connect VT, COM, and OUT terminals to the monitoring system. Keep field wiring under the maximum limit of 305 meters (1000 feet) to prevent high-frequency signal roll-off.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge:\u003c\/strong\u003e Although terminals are protected against ESD, exercise proper handling procedures (such as wearing a grounded wrist strap) during field connection and configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\nOption 05 designates multiple hazardous area approvals, verifying compliance with several standard regulatory environments:\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA\/NRTL\/C:\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III (Intrinsically Safe when installed with approved zener barriers or galvanic isolators).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e II 1 G Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc (for EPL Dc). Ex nA IIC T5...T1 Gc; Ex ec IIC T5...T1 Gc (for EPL Gc).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEuropean Community Directive:\u003c\/strong\u003e CE mark compliant with EMC Directive (EN 61000-6-2 and EN 61000-6-4) and RoHS Directive (2011\/65\/EU).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e Certified up to SIL 2 (HFT = 0) or SIL 3 (HFT = 1) configurations in machinery protection schemes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666625524075,"sku":"330780-91-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330780-91-05-3300-xl-11-mm-proximitor-sensor-045r4gjtbwi_eceab253-f5d4-4608-bfdd-fbdad221d90c.jpg?v=1765444331"},{"product_id":"bently-nevada-330180-x1-05mod-145004-67-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05MOD:145004-67 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-X1-05MOD:145004-67\u003c\/strong\u003e: This \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e is calibrated specifically for a 17CrNiMo6 target material (CT-0176 target CT number) under the custom 145004 recalibration modification family. This 9-meter DIN-mount (Option X1) sensor is configured with Option 05 agency approvals and is engineered to work in conjunction with 3300 XL 5mm or 8mm proximity probes and extension cables to monitor machinery vibration and axial position.\u003c\/p\u003e\n\u003cp\u003eUnlike standard 330180 Proximitor sensors that are factory-calibrated for standard AISI 4140 steel targets, the custom 145004-67 modification recalibrates the internal oscillator and detection circuitry. This modification shifts the target material calibration to 17CrNiMo6 alloy steel, maintaining an average scale factor (ASF) of 200 mV\/mil (7.87 V\/mm) and a linear range of 10 to 90 mils (0.25 to 2.25 mm). This precise recalibration reduces material-induced measurement errors on rotating shafts comprised of 17CrNiMo6.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCustom 145004-67 modification provides precise recalibration for 17CrNiMo6 steel shafts with a target CT number of CT-0176.\u003c\/li\u003e\n  \u003cli\u003eOption X1 mounting provides standard DIN-rail mount configuration for industrial enclosure installation.\u003c\/li\u003e\n  \u003cli\u003eOption 05 agency approvals offer certified compatibility for hazardous areas, meeting multiple international explosion protection standards.\u003c\/li\u003e\n  \u003cli\u003e9-meter system compatibility matches standard 3300 XL 5mm and 8mm probes and extension cables.\u003c\/li\u003e\n  \u003cli\u003eElectrical zero of -3.0 Vdc @ 20 mils ensures consistent calibration starting points for eddy-current measurements.\u003c\/li\u003e\n  \u003cli\u003eAverage scale factor of 200 mV\/mil (7.87 V\/mm) with a linear range spanning from 10 to 90 mils (0.25 to 2.25 mm).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical heavy-industry scenarios include machinery condition monitoring on rotating shafts made of 17CrNiMo6 chrome-nickel-molybdenum steel alloy. It is used for shaft vibration and axial position measurement on industrial steam turbines, gas turbines, turbo-compressors, motors, and high-speed pumps, especially in installations requiring DIN-rail mounted monitoring hardware in hazardous areas.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-X1-05MOD:145004-67\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 5mm\/8mm 9m Proximitor Sensor with Custom Calibration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOption A - Total Length and Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eX1\u003c\/td\u003e\n      \u003ctd\u003eX1 Modification, DIN Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOption B - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx approvals (Multiple Approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModification Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMOD 145004\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 5mm\/8mm 9m Recalibration to Various Target Materials Modification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOption C - Target Material Calibration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e67\u003c\/td\u003e\n      \u003ctd\u003eCalibrated to 17CrNiMo6 Target Material (Target CT # CT-0176)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330180-X1-05MOD:145004-67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDevice Type\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Type\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 5mm\/8mm 9-Meter System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCalibrated Target Material\u003c\/td\u003e\n      \u003ctd\u003e17CrNiMo6 (CT-0176)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e10 to 90 mils (0.25 to 2.25 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAverage Scale Factor (ASF)\u003c\/td\u003e\n      \u003ctd\u003e200 mV\/mil (7.87 V\/mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF) Tolerance\u003c\/td\u003e\n      \u003ctd\u003e+\/- 18 mV\/mil from 0 to 45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Zero\u003c\/td\u003e\n      \u003ctd\u003e-3.0 Vdc @ 20 mils\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Option\u003c\/td\u003e\n      \u003ctd\u003eDIN-rail mount (X1 Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Length\u003c\/td\u003e\n      \u003ctd\u003e9 meters\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-51 to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCalibration Temperature\u003c\/td\u003e\n      \u003ctd\u003e+23 degC +\/- 3 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 61.2 mm x 103.1 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Name\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eProximitor sensor output analog voltage signal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon reference \/ system ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVTX\u003c\/td\u003e\n      \u003ctd\u003eNegative supply voltage input (-24 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOAX\u003c\/td\u003e\n      \u003ctd\u003eCoaxial connector terminal for probe extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the Proximitor sensor inside a weatherproof industrial enclosure or dedicated housing to protect against moisture and environmental contamination. Ensure the Proximitor housing is properly isolated from structural grounds if using standard non-isolated mounting hardware. Run coaxial extension cables through metal conduit or armored cable trays to prevent physical damage and electrical noise interference. Always verify that the total length of the probe and extension cable combined matches the 9-meter calibration of this Proximitor sensor before applying power. Adjust the probe-to-target gap using a digital voltmeter connected to the OUT and COM terminals to verify the correct electrical zero voltage at the installation operating gap.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis Proximitor sensor complies with international standards for hazardous areas under Option 05 approvals, including ATEX, IECEx, and CSA certifications for intrinsically safe and non-incendive installations in hazardous atmospheres.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666626736491,"sku":"330180-X1-05 MOD:145004-67","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145004-67-3300-xl-proximitor-sensor-ubqsjvxhygr_a915a367-98e9-4eed-93a6-7d15387cefda.jpg?v=1765444346"},{"product_id":"bently-nevada-330780-90-05-3300-xl-11-mm-proximitor-sensor","title":"Bently Nevada 330780-90-05 3300 XL 11 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330780-90-05\u003c\/strong\u003e is an advanced eddy current measurement device within the \u003cstrong\u003e3300 XL 11 mm Proximitor Sensor\u003c\/strong\u003e series, designed to process signals from a proximity probe and extension cable combination. It delivers a continuous, linear voltage output directly proportional to the static distance (gap) or dynamic vibration between the probe tip and the observed target. This sensor is explicitly engineered for high-performance fluid-film bearing machinery monitoring and vibration analysis within critical machinery protection systems, including the \u003cstrong\u003eBently Nevada 3500 System\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe hardware offers reliable input-output capabilities by converting target movement into standard industrial electrical signals, allowing direct interfacing with machinery protection monitors, distributed control systems (DCS), and plant asset management networks. This module features robust physical protection and EMI\/RFI immunity, enabling deployment across severe industrial applications such as oil and gas processing, petrochemical production, power generation facilities, and mining installations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearized Voltage Output:\u003c\/strong\u003e Delivers exceptional accuracy and repeatable calibration for vibration, gap, and speed measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Fully compatible with standard \u003cstrong\u003e3300 XL 11 mm\u003c\/strong\u003e proximity probes and extension cables, integrating with monitoring architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced RFI\/EMI Immunity:\u003c\/strong\u003e Provides robust resistance against electromagnetic interference without requiring specialized external conduit housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting Option:\u003c\/strong\u003e Features a flexible physical design supporting convenient standard DIN rail mounting or traditional panel installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Coaxial Connector Protectors:\u003c\/strong\u003e Prevents moisture ingress and external contamination, maintaining signal integrity at the physical interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal and axial compressors\u003c\/li\u003e\n\u003cli\u003eIndustrial pumps and electric motors\u003c\/li\u003e\n\u003cli\u003eHydroelectric generators\u003c\/li\u003e\n\u003cli\u003eCooling tower fans and gearboxes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330780-90-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.0 metres (29.5 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (ATEX, IECEx, CSA, TR CU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.94 V\/mm (100 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVT \/ -24 Vdc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOUT \/ SIG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear Voltage Output Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM \/ GND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon \/ Ground Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROBE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoaxial Interface to Extension Cable \/ Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eGrounding and Shielding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the sensor housing is insulated from the underlying structure or connected to the designated system ground to eliminate potential ground loop interference.\u003c\/li\u003e\n\u003cli\u003eMaintain the continuous shield from the probe connection back to the monitor panel, grounding the shield only at the monitor common point.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProbe Gap Adjustment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdjust the initial physical gap between the target material and the probe tip until the output voltage reads approximately -10.0 Vdc, corresponding to the midpoint of the linear operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Routing and Physical Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute all interconnecting coaxial cables away from high-voltage machinery lines or structural paths prone to extreme mechanical vibration.\u003c\/li\u003e\n\u003cli\u003eInstall physical connector protectors over the coaxial junctions to maintain proper signal protection against fluids, grease, and ambient moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX \/ IECEx Zone 0, Zone 2\u003c\/li\u003e\n\u003cli\u003eCSA Class I, Division 1 and 2\u003c\/li\u003e\n\u003cli\u003eTR CU (EAC) Hazardous Area Approvals\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666629194091,"sku":"330780-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330780-90-05-3300-xl-11-mm-proximitor-sensor-rs0uriynwfh_ad731d20-c6d3-47ee-bda1-91e3dbb1d94e.jpg?v=1765444374"},{"product_id":"bently-nevada-330180-90-00-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-90-00 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-90-00\u003c\/strong\u003e: 3300 XL Proximitor Sensor, configured for a 9.0-meter system length with standard panel-mount housing and no hazardous area agency approvals. This configuration conditions and drives the proximity probe signal in machinery protection networks, outputting a continuous analog DC voltage proportional to the dynamic gap distance between the probe tip and the target material.\u003c\/p\u003e\n\u003cp\u003eUnlike the 1.0-meter or 5.0-meter variants, this 9.0-meter system version matches the combined impedance requirements of 3300 XL 8 mm proximity probes and extension cables calibrated to a total 9.0-meter physical length. The integrated base plate provides galvanic isolation without separate insulating hardware, minimizing installation footprint and simplifying direct mounting to equipment panels or junction enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e9.0-meter total system length tuning matches specific 3300 XL probe and extension cable pairings\u003c\/li\u003e\n\u003cli\u003eIntegrated panel-mount base footprint for mounting directly to bulkheads or inside instrument enclosures\u003c\/li\u003e\n\u003cli\u003eSpring-loaded terminal strips accept tinned field wiring without screw clamping mechanisms\u003c\/li\u003e\n\u003cli\u003eConstructed with an A308 aluminum housing and gold-plated coaxial connectors\u003c\/li\u003e\n\u003cli\u003eHigh immunity to radio frequency interference allows mounting inside non-metallic enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical applications include shaft vibration, axial position, and speed measurements on rotating machinery such as steam turbines, gas compressors, industrial pumps, and electric motor bearings.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Code\u003c\/th\u003e\n      \u003cth\u003eValue on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-90-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Total Length \u0026amp; Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, panel mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n      \u003ctd\u003e330180-90-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDevice Type\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System (9.0 m configuration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput\u003c\/td\u003e\n      \u003ctd\u003eAccepts one non-contacting 3300 XL 8 mm proximity probe and extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Requirements\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum consumption\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n      \u003ctd\u003e-1 to -17 Vdc (proportional to gap distance)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) plus\/minus 6.5 percent average over 2.0 mm (80 mil) linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e0.25 mm to 2.3 mm (10 mils to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eA308 Aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 63.5 mm x 50.8 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.246 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the panel-mount base directly to a flat, electrically conductive surface using the integrated mounting plate. Use standard 3-conductor shielded triad field cable (18 AWG \/ 1.0 mm2 recommended) to connect the terminal strips to the monitoring rack system. Ensure that the total loop length of the probe and extension cable is exactly 9.0 meters to maintain calibration with the sensor. Connectors must be kept clean, dry, and protected using connector protectors or self-fusing tape when exposed to harsh environments.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eComplies with European CE Mark requirements for electromagnetic compatibility and RF\/EMI immunity without the need for auxiliary metal conduit or enclosures. Complies with FCC part 15 rules.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666630963563,"sku":"330180-90-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-90-00-3300-xl-proximitor-sensor-pcp0spjgqmy_30c44eca-b870-4223-b467-1328c3dc031f.jpg?v=1765444395"},{"product_id":"bently-nevada-330878-91-00-3300-xl-50-mm-proximity-transducer-system-proximitor-sensor","title":"Bently Nevada 330878-91-00 3300 XL 50 mm Proximity Transducer System Proximitor Sensor","description":"\u003cp\u003eThe \u003cstrong\u003e330878-91-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL 50 mm Proximitor Sensor\u003c\/strong\u003e designed as an essential signal processing interface for eddy current proximity transducer systems. The device accepts a noncontacting input from one 3300 XL 50 mm Proximity Probe and Extension Cable, converting the measured gap between the probe tip and a target into a proportional voltage output. Engineered specifically for long-range displacement monitoring, this sensor is optimized for measuring differential expansion (DE) or rotor expansion (RX) on fluid-filmed bearing machines such as large steam turbine generators. It features a thin layout ideal for high-density configurations and provides complete backwards signal compatibility with older legacy 7200 and 50 mm DE Integral systems by maintaining an identical output scale factor.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density DIN Rail Mount\u003c\/strong\u003e: Designed with a slim enclosure layout optimized for space-efficient installation on standard 35 mm DIN rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced EMI\/RFI Immunity\u003c\/strong\u003e: Restricts high-frequency radio signal disruptions and fulfills European CE mark criteria without specialized installation adjustments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eToolless Field Connections\u003c\/strong\u003e: Utilizes \u003cstrong\u003eSpringLoc\u003c\/strong\u003e terminal strips to facilitate fast, robust field wiring installation without requiring specialized tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Factory Calibration\u003c\/strong\u003e: Pre-calibrated by default to an AISI 4140 steel target for plug-and-play operation in industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDifferential expansion (DE) tracking on high-power steam turbine generators.\u003c\/li\u003e\n\u003cli\u003eRotor expansion (RX) measurement resulting from thermal growth variations between rotors and casings.\u003c\/li\u003e\n\u003cli\u003eLarge-scale axial displacement tracking on industrial rotating machines.\u003c\/li\u003e\n\u003cli\u003eDual complementary input transducer setups designed to expand the overall measurable displacement range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ch3\u003eOrdering Option Breakdown for 330878-91-00\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330878\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 50 mm Proximitor Sensor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption A (Total Length and Mounting)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e91\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.0 meters (29.5 feet) system length, DIN mount \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption B (Agency Approval)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo Approvals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330878-91-00 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 50 mm Proximitor Sensor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.9 mm (1100 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e394 mV\/mm (10 mV\/mil) nominal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than ±0.74 mm (±29 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 XL 50 mm Proximity Probe and Extension Cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ohm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtension Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than a 3% change in Average Scale Factor (ASF) when tested per IEC standard 68-2-66 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with the European CE mark \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Mount the device on a 35 mm DIN rail inside a protective industrial control enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length Verification\u003c\/strong\u003e: Ensure the exact physical lengths of the paired proximity probe and extension cable combined equal the 9.0-meter specified system length of the sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Material\u003c\/strong\u003e: Use three-conductor shielded triad cable for terminal connections to maintain optimal signal performance. Route sensor wiring separately from high-voltage cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Constraints\u003c\/strong\u003e: Maintain a clean DC power input within the -17.5 Vdc to -26 Vdc threshold. Avoid operating voltages more positive than -23.5 Vdc as this can reduce the total linear range.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666631553387,"sku":"330878-91-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330878-91-00-plc-controller-tmvmjbkjezz_b82ae707-d15a-4931-ad54-892c92f4ae61.jpg?v=1765444404"},{"product_id":"bently-nevada-330180-12-00-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-12-00 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-12-00\u003c\/strong\u003e: 3300 XL Proximitor Sensor configured for a 1.0 meter total system length with no mounting hardware (Option 12) and without agency approvals (Option 00).\u003c\/p\u003e\n\u003cp\u003eThis configuration pairs with a 1.0 meter proximity probe and extension cable system to process raw eddy-current signal data. It provides an analog displacement output for machinery protection and monitoring networks, converting the physical gap distance into a proportional voltage signal of -200 mV\/mil. The 330180-12-00 converts high-frequency RF signal fluctuations into a standard -1 Vdc to -17 Vdc analog output, which corresponds to a 2.0 mm (80 mil) linear measurement range when used with compatible components. This model is supplied as a standalone module without panel-mount or DIN-rail plates, intended for direct installation into custom mounting brackets or replacement of existing sensors within pre-fitted enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 12 specifies a 1.0 meter (3.3 feet) total system length calibration.\u003c\/li\u003e\n  \u003cli\u003eOption 00 indicates standard non-hazardous area configuration with no agency approvals.\u003c\/li\u003e\n  \u003cli\u003eSupplied without DIN-rail or panel-mounting hardware plates for standalone or custom containment.\u003c\/li\u003e\n  \u003cli\u003eFeatures SpringLoc terminal strips for field wire connections up to 1.5 mm2 (16 AWG).\u003c\/li\u003e\n  \u003cli\u003eMaintains compatibility with 3300-series 5 mm and 3300 XL 8 mm proximity probe and extension cable hardware.\u003c\/li\u003e\n  \u003cli\u003eDelivers a calibrated -200 mV\/mil (7.87 V\/mm) analog output sensitivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 330180-12-00 Proximitor Sensor is deployed in machine monitoring loops across heavy-industry assets, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on industrial steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eCasing expansion and radial displacement monitoring on centrifugal compressors.\u003c\/li\u003e\n  \u003cli\u003eCritical motor and heavy industrial pump bearing wear telemetry.\u003c\/li\u003e\n  \u003cli\u003eRebuilding or upgrading older legacy proximity systems in existing instrument cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-12-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Total Length and Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) system length, no mounting hardware\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required \/ Standard configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330180-12-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDevice Type\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal System Length\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Range\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (at 12 mA maximum current draw)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e0.25 to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n      \u003ctd\u003eSpringLoc terminal block (accepts 0.2 to 1.5 mm2 \/ 16 to 24 AWG wire)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Material\u003c\/td\u003e\n      \u003ctd\u003eA308 aluminum housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 61.0 mm x 50.8 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.246 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eProportional voltage analog output signal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eSystem common reference ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003eNegative DC power supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOAXIAL INPUT\u003c\/td\u003e\n      \u003ctd\u003eCoaxial connection terminal for proximity probe or extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the total combined electrical length of the connected proximity probe and extension cable equals the 1.0 meter calibration of the Proximitor sensor.\u003c\/li\u003e\n  \u003cli\u003eUtilize triaxial coaxial connectors (ClickLoc) between components, and ensure they are tightened finger-tight.\u003c\/li\u003e\n  \u003cli\u003eTerminate field wiring at the SpringLoc terminals using a small flat-blade screwdriver; do not use screw terminals. Supported wire gauges are 0.2 mm2 to 1.5 mm2 (16 to 24 AWG).\u003c\/li\u003e\n  \u003cli\u003eInstall the sensor within a protected fiberglass or metal weather-proof enclosure if local environmental conditions exceed the IP rating or if mounting in high-moisture outdoor applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFCC Part 15 compliant\u003c\/li\u003e\n  \u003cli\u003eCE Mark (EMC Directive 2014\/30\/EU, RoHS Directive 2011\/35\/EU)\u003c\/li\u003e\n  \u003cli\u003eStandard safe-area application (Option 00 - Agency approvals not required)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666633486699,"sku":"330180-12-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-12-00-3300-xl-proximitor-sensor-2gq0mimicuf_f56135c5-c2a8-425a-96c9-4b38589416bc.jpg?v=1765444433"},{"product_id":"bently-nevada-330180-50-cn-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-50-CN 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 50 (5.0 m system length, panel mount) and the -CN China hazardous area approval package specify this 3300 XL Proximitor Sensor configuration — \u003cstrong\u003e330180-50-CN\u003c\/strong\u003e. This sensor conditions and drives the signal for 3300 XL 8 mm proximity probes, translating the high-frequency eddy-current signal into a proportional DC voltage displacement output for machinery protection and condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eUnlike 1.0 m or 9.0 m variants, the Option 50 system length must be matched with a 5-meter probe and extension cable combination to form a calibrated 5.0-meter transducer loop. The panel-mount design offers a standard four-hole mounting footprint that is physically interchangeable with legacy Bently Nevada Proximitor sensors, while the integrated electrical isolation in the housing base eliminates the requirement for additional isolator plates. The -CN approval package ensures full compliance with local Chinese hazardous area regulatory frameworks, including NEPSI and CCC certifications, allowing safe deployment in explosive environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 50 configuration provides compatibility with 5.0-meter transducer systems (probe plus extension cable totaling 5 meters).\u003c\/li\u003e\n  \u003cli\u003ePanel-mount housing features a traditional four-hole footprint, allowing simple mechanical drop-in replacement.\u003c\/li\u003e\n  \u003cli\u003e-CN China approval package adds verified CCC and NEPSI hazardous area safety compliance.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in electrical isolation in the mounting base eliminates the need for separate isolator plates.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal block ensures secure, tool-free field wiring that resists loosening under vibration.\u003c\/li\u003e\n  \u003cli\u003eHighly immune to radio frequency interference (RFI) and electromagnetic interference (EMI), satisfying European CE requirements without metal conduit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis 3300 XL Proximitor Sensor is used for rotating machinery monitoring. Common applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft dynamic vibration and axial position measurement on steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eRadial dynamic motion and casing vibration monitoring in centrifugal compressors.\u003c\/li\u003e\n  \u003cli\u003eRotor position and bearing clearance tracking on heavy-duty electric motors and pumps.\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor rod position and crosshead vibration monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe 330180-50-CN is an orderable configuration of the Bently Nevada 3300 XL Proximitor Sensor. The segment breakdown for this specific SKU is detailed below:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-50-CN\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, 5.0 m system length, panel mount, China hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOption A - Total Length and Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) system length, panel mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSuffix - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-CN\u003c\/td\u003e\n      \u003ctd\u003eChina hazardous area approval package (NEPSI + CCC + applicable markings)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-50-CN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePanel mount (4-hole footprint)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Input Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc (at 12 mA maximum consumption); -23 Vdc to -26 Vdc with safety barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Signal \/ Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDisplacement voltage output; 50 Ohm output resistance\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRFI \/ EMI Immunity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSatisfies CE requirements without special shielded conduit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 3% change in Average Scale Factor (ASF) after 56 days at 93% relative humidity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 61.0 mm x 63.5 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e246 g (0.246 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eSignal Description\u003c\/th\u003e\n      \u003cth\u003eWiring Connection Guide\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProportional Voltage Output\u003c\/td\u003e\n      \u003ctd\u003eConnect to monitor dynamic input channels (vibration\/position)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Ground\u003c\/td\u003e\n      \u003ctd\u003eSystem ground reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower Supply Input (-24 Vdc)\u003c\/td\u003e\n      \u003ctd\u003eNegative DC excitation voltage input (-17.5 to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFollow these mechanical and electrical installation guidelines for the 330180-50-CN Proximitor Sensor:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Length Matching:\u003c\/strong\u003e Pair this sensor only with a 5.0-meter probe and extension cable combination (such as a 1.0 m probe plus a 4.0 m extension cable). Mismatched lengths degrade calibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e The mounting base provides electrical isolation from the panel surface. Ensure mounting screws are tightened to secure the unit without bypassing this built-in isolation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Connections:\u003c\/strong\u003e Use tinned, three-conductor shielded triad field wire (0.2 to 1.5 mm2 or 16 to 24 AWG). Insert wires into the SpringLoc terminal blocks until clamped.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Distance:\u003c\/strong\u003e Keep field wiring between the Proximitor sensor and the monitoring rack under 305 meters (1,000 feet) to prevent signal loss.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330180-50-CN conforms to the following standards and approvals:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC (China Compulsory Certification):\u003c\/strong\u003e Certified for explosive and hazardous environments in China.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNEPSI (National Supervision and Inspection Center for Explosion Protection and Safety of Instrumentation):\u003c\/strong\u003e Intrinsic Safety and Non-Incendive approvals for hazardous areas in the People's Republic of China.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Fully compliant with EU electromagnetic compatibility directives without metallic conduit requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666634436971,"sku":"330180-50-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-50-cn-3300-nsv-proximity-probes-x52rcjc4eae_79b4a1ef-a726-4875-b9d0-e3b7c7e6be15.jpg?v=1765444447"},{"product_id":"bently-nevada-330500-00-20-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-00-20 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330500-00-20\u003c\/strong\u003e is a Bently Nevada Velomitor Piezo-velocity Sensor configuration featuring Option 00 (no mounting adapter) and the specified Option 20 configuration. This solid-state piezoelectric accelerometer is engineered to measure absolute casing, bearing housing, and structural vibration. By incorporating integrated electronics and utilizing a solid-state design without moving parts, the 330500 series eliminates mechanical degradation and wear commonly found in older velocity transducer technologies.\u003c\/p\u003e\n\n\u003cp\u003eThis sensor is suitable for vertical, horizontal, or angled mounting orientations. The 330500 provides a consistent velocity output, making it effective for identifying machine malfunctions such as unbalance and misalignment that transmit significant vibration to the machine casing. Note that this specific unit is shipped without a factory-installed mounting adapter (Option 00), providing flexibility for direct mounting or integration into existing machine interfaces.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSolid-state piezoelectric design with no moving parts to prevent mechanical wear\u003c\/li\u003e\n\u003cli\u003eCompatible with horizontal, vertical, and angular mounting orientations\u003c\/li\u003e\n\u003cli\u003eHousing constructed from 316L stainless steel for durability in industrial environments\u003c\/li\u003e\n\u003cli\u003eHermetically-sealed connector shell (2-pin MIL-C-5015)\u003c\/li\u003e\n\u003cli\u003eProvides absolute vibration measurement for casing and bearing housing protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCasing and structural vibration monitoring\u003c\/li\u003e\n\u003cli\u003eBearing housing vibration measurements\u003c\/li\u003e\n\u003cli\u003eRotating machinery protection for pumps, fans, and compressors\u003c\/li\u003e\n\u003cli\u003eGeneral industrial machine vibration diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330500-00-20\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread Adapter\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Configuration Code\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eFactory specified configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e330500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/- 5 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz (270 cpm to 300 kcpm) +\/- 3.0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude Linearity\u003c\/td\u003e\n\u003ctd\u003e+\/- 2 percent to 152 mm\/s (6 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Bias Voltage\u003c\/td\u003e\n\u003ctd\u003e-12 +\/- 3.0 VDC referenced to Pin A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Output Impedance\u003c\/td\u003e\n\u003ctd\u003eLess than 2400 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to 121 degC (-67 degF to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015 hermetically-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e32-46 kg cm (24-40 in-lb) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.142 kg (5.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the sensor is installed on a rigid part of the bearing housing or machine casing to maintain accurate frequency and amplitude response. Improper installation or loose mounting may generate false signals that do not represent actual machine vibration. The device is hermetically sealed, but care should be taken to ensure the 2-pin connector is properly seated and protected from environmental contaminants if installed in harsh areas. Refer to the standard 330500 instruction manuals for mounting torque and cabling practices.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330500 Velomitor Piezo-velocity Sensor complies with EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU. The product is rated for maritime applications, including ABS Marine Vessels, Offshore Units, and Structures. For detailed hazardous area approval status, consult the Bently Nevada Approvals Quick Reference Guide (108M1756).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666635059563,"sku":"330500-00-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-00-20-velomitor-piezo-velocity-sensor-5pzvz5hraxz_3c779b50-82d6-413f-b1dc-aac85d550d96.jpg?v=1765444456"},{"product_id":"bently-nevada-330500-02-01-velomitor-piezo-velocity-sensor","title":"Bently Nevada 330500-02-01 Velomitor Piezo-velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330500-02-01\u003c\/strong\u003e: \u003cstrong\u003eVelomitor Piezo-velocity Sensor\u003c\/strong\u003e configured with an M8 x 1 mounting thread adapter (Option 02) and CSA\/US\/C hazardous area certification (Option 01). This device measures absolute bearing housing, casing, or structural vibration relative to free space. It consists of a specialized piezoelectric accelerometer combined with embedded solid-state electronics, providing a direct velocity-proportional voltage output without requiring external signal conditioning modules.\u003c\/p\u003e\n\n\u003cp\u003eIn contrast to standard variants that utilize 1\/2-20 UNF (Option 01) or 1\/4-28 UNF (Option 03) mounting studs, this configuration includes the M8 x 1 metric thread adapter to match specific machinery housings. Since the internal architecture utilizes solid-state piezoelectric elements rather than moving mechanical parts, the sensor is immune to mechanical degradation and wear. This design permits installation at any orientation, including horizontal, vertical, or angled mounts, without affecting measurement sensitivity or long-term calibration stability.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSolid-state engineering eliminates mechanical components to prevent internal wear and calibration drift.\u003c\/li\u003e\n  \u003cli\u003eOption 02 provides a factory-matched M8 x 1 threaded mounting adapter for metric housing interfaces.\u003c\/li\u003e\n  \u003cli\u003eOption 01 guarantees CSA\/US\/C approval for installation in Division 1 and Division 2 hazardous areas.\u003c\/li\u003e\n  \u003cli\u003eCorrosion-resistant housing constructed from hermetically-sealed 316L stainless steel.\u003c\/li\u003e\n  \u003cli\u003eIsolated case design protects signal paths from electromagnetic interference and local ground loops.\u003c\/li\u003e\n  \u003cli\u003eSupports extensive signal runs up to 305 m (1,000 ft) without degradation when paired with approved cabling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCasing vibration diagnostics on industrial steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eAbsolute vibration tracking on high-power electric motors and generators.\u003c\/li\u003e\n  \u003cli\u003eBearing housing protection on centrifugal compressors, pumps, and fans.\u003c\/li\u003e\n  \u003cli\u003eBalance and alignment analysis on critical rotating machinery trains.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330500-02-01\u003c\/td\u003e\n      \u003ctd\u003eVelomitor Piezo-velocity Sensor with M8 x 1 adapter and CSA approval\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Mounting Thread Adaptor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eM8 x 1 mounting adapter included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eCSA\/US\/C certification (Intrinsically Safe and Non-Incendive ratings)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330500-02-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Parameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAbsolute velocity (integrated from acceleration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/-5% at 100 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.5 Hz to 5 kHz +\/-3.0 dB (6.0 Hz to 2.5 kHz +\/-0.9 dB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVelocity Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 5% of axial sensitivity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmplitude Linearity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/-2% up to 152 mm\/s (6 in\/s) peak\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounted Resonant Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGreater than 12 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Bias Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-12 +\/-3.0 VDC referenced to Pin A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDynamic Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2400 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBroadband Noise Floor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.004 mm\/s (160 uin\/s) rms, nominal (4.5 Hz to 5 kHz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCase isolated from internal circuitry\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 m (1,000 ft) using standard Bently Nevada cable 02173006\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-55 degC to 121 degC (-67 degF to 250 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShock Survivability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5,000 g peak maximum limit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 100% non-submerged; hermetically-sealed shell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e316L stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2-pin MIL-C-5015 hermetically-sealed receptacle\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e32-46 kg cm (24-40 in-lb) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.3 mm (0.995 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e63.2 mm (2.49 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Pin\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin A\u003c\/td\u003e\n      \u003ctd\u003ePositive signal output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin B\u003c\/td\u003e\n      \u003ctd\u003eSignal common \/ return\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify machinery mounting surfaces are flat, clean, and drilled to accommodate the M8 x 1 mounting thread.\u003c\/li\u003e\n  \u003cli\u003eEnsure torque is applied using a calibrated wrench to remain within the 32-46 kg cm (24-40 in-lb) limit during adapter and sensor installation.\u003c\/li\u003e\n  \u003cli\u003eAlign the MIL-C-5015 connector pins and secure the mating cable collar firmly to achieve a moisture-resistant connection.\u003c\/li\u003e\n  \u003cli\u003eTo prevent inaccurate displacement data caused by noise amplification, exercise caution if integrating the velocity signal to displacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA\/NRTL\/C\u003c\/strong\u003e: Class I, Division 1, Groups A, B, C, and D; Class II, Groups E, F, and G; Class III; Ex ia IIC T3, AEx ia IIC T3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC\u003c\/strong\u003e: Electromagnetic Compatibility Directive 2014\/30\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFCC\u003c\/strong\u003e: Compliant with FCC Part 15 regulations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS\u003c\/strong\u003e: Compliant with EU Directive 2011\/65\/EU and China RoHS regulations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaritime\u003c\/strong\u003e: ABS Marine Vessels, Offshore Units and Structures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666637451627,"sku":"330500-02-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330500-02-01-velomitor-piezo-velocity-sensors-zt3ruhc0yfc_9c6c55f7-9656-4e71-9fa1-5c74f80564e3.jpg?v=1765444497"},{"product_id":"bently-nevada-330780-91-cn-3300-xl-11-mm-proximitor-sensor","title":"Bently Nevada 330780-91-CN 3300 XL 11 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330780-91-CN\u003c\/strong\u003e specifies the 9.0 m DIN-rail mount configuration of the \u003cstrong\u003e3300 XL 11 mm Proximitor Sensor\u003c\/strong\u003e, equipped with the China hazardous area approval package. This sensor performs non-contacting eddy-current displacement measurement within 3300 XL 11 mm monitoring chains, outputting an analog voltage directly proportional to the distance between the probe tip and the observed target surface.\u003c\/p\u003e\n\u003cp\u003eThis variant pairs with 3300 XL 11 mm probes and extension cables to monitor shaft vibration, axial position, and rotor dynamics. Unlike the 5.0 m options or panel-mount configurations, this model is factory-calibrated for a 9.0 m system length and integrates DIN-rail mounting hardware. Additionally, the -CN suffix designates NEPSI and CCC certifications required for localized hazardous area compliance in the Chinese market.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 91 specifies a 9.0-meter system length configured for DIN-rail mounting.\u003c\/li\u003e\n  \u003cli\u003eSuffix -CN designates the China hazardous area approval package including NEPSI and CCC certification.\u003c\/li\u003e\n  \u003cli\u003eAccepts input from 3300 XL 11 mm proximity probes and matching extension cables.\u003c\/li\u003e\n  \u003cli\u003eGenerates a continuous analog voltage output of 3.94 V\/mm (100 mV\/mil).\u003c\/li\u003e\n  \u003cli\u003eUses gold-plated brass ClickLoc coaxial connectors for physically secure cabling.\u003c\/li\u003e\n  \u003cli\u003eConstructed with an A380 aluminum housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial position monitoring\u003c\/li\u003e\n  \u003cli\u003eCentrifugal and axial compressor rotor dynamics\u003c\/li\u003e\n  \u003cli\u003eIndustrial pump and generator shaft position tracking\u003c\/li\u003e\n  \u003cli\u003eCritical rotating machinery protection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330780-91-CN\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximitor Sensor with 9.0 m system length, DIN-rail mounting, and China approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA: Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e91\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, DIN-rail mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSuffix\u003c\/td\u003e\n      \u003ctd\u003e-CN\u003c\/td\u003e\n      \u003ctd\u003eChina hazardous area approval package (NEPSI + CCC + applicable markings)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330780-91-CN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Input Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one 3300 XL 11 mm proximity probe and extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Input Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAnalog Output Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/- 10% typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), beginning at approximately 0.5 mm (20 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz (+0, -3 dB typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing (non-submersible with protected connectors)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eTerminal Connection Function\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003eVoltage Transmitter \/ Power Supply (-24 Vdc nominal input)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon Ground Reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eTransducer Analog Output Signal\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the Proximitor sensor is mounted on a 35 mm DIN rail in a dry, clean industrial enclosure providing a minimum of IP54 protection. Maintain appropriate clearance for field wiring and terminal connections. Use three-conductor shielded triad cable (0.2 to 1.5 mm2 or 16 to 24 AWG) for connections between the Proximitor sensor and the monitoring system. Verify that the sum of the probe length and extension cable length matches the 9.0 m system calibration length of the sensor.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330780-91-CN transmitter meets the following compliance requirements:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eNEPSI (National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation) - CN Option\u003c\/li\u003e\n  \u003cli\u003eCCC (China Compulsory Certification) - CN Option\u003c\/li\u003e\n  \u003cli\u003eCE Mark (EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU)\u003c\/li\u003e\n  \u003cli\u003eSIL 2 (HFT = 0) and SIL 3 (HFT = 1) functional safety compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666637615467,"sku":"330780-91-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330780-91-cn-3300-xl-11-mm-proximitor-sensor-4yqeeztrn0k_1b7abd2f-8221-43ec-b97b-976bc17e23b7.jpg?v=1765444500"}],"url":"https:\/\/www.plcprotech.com\/collections\/sensors.oembed?page=8","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}