{"product_id":"3500-91-01-01-01-161204-01-61216-01-egd-communication-gateway-module","title":"3500\/91-01-01-01 161204-01+61216-01 EGD Communication Gateway Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/91-01-01-01 161204-01+161216-01\u003c\/strong\u003e is an Ethernet Global Data (EGD) communication gateway module that provides comprehensive communication capabilities for 3500 rack-monitored values and status. It offers an Ethernet network path with response times suitable for controller applications and integrates seamlessly with EGD protocol-compatible controllers. The assembly consists of the 3500\/91 EGD Gateway Main Module (161204-01) and the Ethernet 10BASE-T\/100BASE-TX I\/O Module (161216-01).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTransmits rack, module, channel, and data value statuses, as well as float data values and setpoints.\u003c\/li\u003e\n\u003cli\u003eSupports group control functions including Group Reset, Group Trip Multiply, Group Alarm Inhibit, and Group Special Alarm Inhibit.\u003c\/li\u003e\n\u003cli\u003eEquipped with front panel status LEDs including OK LED and TX\/RX LED.\u003c\/li\u003e\n\u003cli\u003eIntegrates via RJ-45 jack for Ethernet 10BASE-T\/100BASE-TX twisted pair connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegration of 3500 rack monitoring data into EGD protocol-compatible controllers.\u003c\/li\u003e\n\u003cli\u003eReal-time machinery condition monitoring and plant control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Part\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/91-AA-BB-CC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/91 EGD Communication Gateway\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Main Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e EGD Communication Gateway Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: I\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e Ethernet 10BASE-T\/100BASE-TX I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e CSA\/NRTL\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e161204-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/91 EGD Gateway Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e161216-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet 10BASE-T\/100BASE-TX I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e161232\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/91 User Guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \/ Baker Hughes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEGD (Version 2.01), Ethernet UDP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 CSMA\/CD; 10BASE-T and 100BASE-TX (IEEE 802.3 and IEEE 802.3u)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.4 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.79 kg (1.75 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39 kg (0.85 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Rack Space\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Rack Space\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware \u0026amp; Hardware Requirements:\u003c\/strong\u003e Requires Version 3.70 or higher of 3500 Rack Configuration Software and a 3500\/22M TDI module to communicate with monitor modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Requirements:\u003c\/strong\u003e Requires Version 1.20 or higher of TDI (3500\/22M) firmware. For consumed exchange support, Version 2.21 or higher of 4-Channel firmware is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Limitation:\u003c\/strong\u003e Only 1 EGD module is allowed per 3500 rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Mounting:\u003c\/strong\u003e Mount the main module into 1 full-height front slot and the corresponding I\/O module into the matching full-height rear slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards: EN 61000-6-2, EN 61000-6-4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; Standard: EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Condition of Classification (Steel Vessels Rules, Offshore Units and Structures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus Hazardous Area:\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF) when installed per drawing 149243 or 149244.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF) when installed per drawing 149243 or 149244.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53650359910763,"sku":"3500\/91-01-01-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-91-01-01-01_161204-01_61216-01_3.jpg?v=1785670836","url":"https:\/\/www.plcprotech.com\/cs\/products\/3500-91-01-01-01-161204-01-61216-01-egd-communication-gateway-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}