{"product_id":"abb-el3040-easyline-el3000-series-continuous-gas-analyzer","title":"ABB EL3040 EasyLine EL3000 Series Continuous Gas Analyzer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eABB \u003cstrong\u003eEL3040\u003c\/strong\u003e \u003cstrong\u003eEasyLine EL3000 Series\u003c\/strong\u003e Continuous Gas Analyzer is a wall-mount continuous gas analyzer designed for industrial process monitoring and emission measurement applications. The \u003cstrong\u003eEL3040\u003c\/strong\u003e provides continuous measurement of up to five gas components depending on the integrated analyzer module, including photometer, paramagnetic, electrochemical, thermal conductivity, and zirconium dioxide sensors. Built in an IP65 wall-mountable housing, the \u003cstrong\u003eEL3040\u003c\/strong\u003e supports customizable analog outputs (0\/4-20 mA), digital inputs\/outputs, and serial communications via Modbus, Profibus, or standard Ethernet interfaces.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWall-mount housing design rated to IP65 degree of protection\u003c\/li\u003e\n\u003cli\u003eMeasures up to five gas components per gas analyzer\u003c\/li\u003e\n\u003cli\u003eSupports automatic calibration including control of pumps and solenoid valves\u003c\/li\u003e\n\u003cli\u003eIntegrated Ethernet-10\/100BASE-T interface for configuration, software updates, and optional QAL3 data transfer\u003c\/li\u003e\n\u003cli\u003eOptional QAL3 monitoring functionality according to EN 14181 with internal data storage up to 1 year\u003c\/li\u003e\n\u003cli\u003eBacklit graphics display with 240x160-pixel resolution and menu-driven 5-key user interface\u003c\/li\u003e\n\u003cli\u003eCompatible with Uras26, Limas23, Magnos206, Caldos27, ZO23, and electrochemical oxygen sensor modules\u003c\/li\u003e\n\u003cli\u003eVersion available for measurement of flammable gases in general purpose environments with housing purge\u003c\/li\u003e\n\u003cli\u003eVersion with protection type II 3G for installation in hazardous locations measuring non-flammable gases\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial process gas monitoring\u003c\/li\u003e\n\u003cli\u003eContinuous emission monitoring systems (CEMS)\u003c\/li\u003e\n\u003cli\u003eMeasurement of oxygen in pure gases (nitrogen, carbon dioxide, argon)\u003c\/li\u003e\n\u003cli\u003eHydrogen-cooled turbogenerator monitoring\u003c\/li\u003e\n\u003cli\u003eFlue gas and combustion control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEL3040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEasyLine EL3000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eWall-mount Continuous Gas Analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eGalvanized sheet steel \/ Stainless steel 1.4016 (SAE 430)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e366 mm x 480 mm x 230 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 13-21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC (-15 \/ +10%), 50-60 Hz (±3 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 187 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eBacklit graphics display, 240 x 160 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface\u003c\/td\u003e\n\u003ctd\u003e5 keys (cursor cross and OK), menu-driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e+5 to +45 degC (General); +5 to +40 degC (Uras26 combined \/ Limas23)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 75%, slight condensation allowed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003eMax. 2000 m above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e10\/100BASE-T, 8-pin RJ45 plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2-way or 4-way modules, 0\/4-20 mA, max. load 750 Ohm, 16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\/Outputs\u003c\/td\u003e\n\u003ctd\u003e4 digital inputs (optocouplers, 12-24 VDC), 4 digital outputs (floating contacts max. 30 VDC \/ 1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus Modules\u003c\/td\u003e\n\u003ctd\u003eModbus (RS232 \/ RS485), Profibus (RS485 \/ MBP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003ch4\u003eModbus Module Interface\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Pin 2\u003c\/td\u003e\n\u003ctd\u003eRxD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Pin 3\u003c\/td\u003e\n\u003ctd\u003eTxD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Pin 5\u003c\/td\u003e\n\u003ctd\u003eGND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Pin 2\u003c\/td\u003e\n\u003ctd\u003eRTxD-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Pin 3\u003c\/td\u003e\n\u003ctd\u003eRTxD+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Pin 5\u003c\/td\u003e\n\u003ctd\u003eGND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eProfibus Module Interface\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Pin 2\u003c\/td\u003e\n\u003ctd\u003eM24 (24 V output ground, max. 0.2 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Pin 3\u003c\/td\u003e\n\u003ctd\u003eRxD\/TxD-P (Receive\/transmit data plus, B-line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Pin 5\u003c\/td\u003e\n\u003ctd\u003eDGND (Data transmission potential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Pin 6\u003c\/td\u003e\n\u003ctd\u003eVP (Supply voltage plus, 5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Pin 7\u003c\/td\u003e\n\u003ctd\u003eP24 (24 V output voltage plus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Pin 8\u003c\/td\u003e\n\u003ctd\u003eRxD\/TxD-N (Receive\/transmit data N, A-line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMBP Terminal 1\u003c\/td\u003e\n\u003ctd\u003e+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMBP Terminal 2\u003c\/td\u003e\n\u003ctd\u003eShield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eAnalog Output Module\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 1\u003c\/td\u003e\n\u003ctd\u003eAO1+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 2\u003c\/td\u003e\n\u003ctd\u003eAO1-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 3\u003c\/td\u003e\n\u003ctd\u003eAO2+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 4\u003c\/td\u003e\n\u003ctd\u003eAO2-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 5\u003c\/td\u003e\n\u003ctd\u003eAO3+ (4-way module only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 6\u003c\/td\u003e\n\u003ctd\u003eAO3- (4-way module only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 7\u003c\/td\u003e\n\u003ctd\u003eAO4+ (4-way module only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 8\u003c\/td\u003e\n\u003ctd\u003eAO4- (4-way module only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCable Gland Assignment (Model EL3040 Base)\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eM20\u003c\/td\u003e\n\u003ctd\u003ePower supply connection (5-13 mm cable diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM25\u003c\/td\u003e\n\u003ctd\u003eModbus \/ Profibus (8-17 mm cable diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM25\u003c\/td\u003e\n\u003ctd\u003eNetwork \/ Ethernet (8-17 mm cable diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM25\u003c\/td\u003e\n\u003ctd\u003eAnalog outputs (8-17 mm cable diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM32\u003c\/td\u003e\n\u003ctd\u003eDigital inputs \/ outputs (12-21 mm cable diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Wall-mount housing requires a clearance of 360 mm to allow the front door to swing open completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Purging\u003c\/strong\u003e: Housing purge is mandatory when measuring flammable gases in model EL3040. Purge gas flow rate must be maintained between 10 l\/h and 20 l\/h at a purge pressure of 2-4 hPa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e: The main power supply is galvanically isolated from other circuits by reinforced\/double insulation (PELV on low-voltage side). Connect main power using the supplied 3-pin plug per EN 60320-1\/C14.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Wiring\u003c\/strong\u003e: Maximum terminal capacity for stranded or solid conductors is 1 mm2 (17 AWG). Use wire end ferrules with a maximum conductor cross-section of 0.5 mm2 crimped via Weidmuller PZ 6\/5.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Potential compensation connection supports a maximum wire size of 4 mm2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Conformity\u003c\/strong\u003e: 2006\/95\/EC Low Voltage Directive (EN 61010-1:2001), 2004\/108\/EC EMC Directive (EN 61326-1:2006, EN 61000-3-2:2006, EN 61000-3-3:1995+A1:2001+A2:2005), 94\/9\/EC ATEX Directive (EN 60079-15:2005)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ Hazardous Locations\u003c\/strong\u003e: II 3G Ex nAC II T4 X (Category 3G for measurement of non-flammable gases and vapors)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA Approval (USA\/Canada)\u003c\/strong\u003e: Certified for general purpose environment (CAN\/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 2nd Edition, Certificate No. 1714030)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEPSI (China)\u003c\/strong\u003e: Certified for hazardous locations, Ex nAC II CT4 (Certificate No. GYJ101401X)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGOST-R (Russia)\u003c\/strong\u003e: Certificate No. POCC DE.HO03.B03490, Rostekhnadzor PPC 00-39671, Pattern approval DE.C.31.004.A No. 37984\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance Testing\u003c\/strong\u003e: EN 15267, EN 14181 (QAL1), EN ISO 14956, 27th\/30th BImSchV, and TA-Luft\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53644166529387,"sku":"EL3040","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-el3040_65869ebe-129b-4b86-ab84-37ac111fdbeb.jpg?v=1785593071","url":"https:\/\/www.plcprotech.com\/cs\/products\/abb-el3040-easyline-el3000-series-continuous-gas-analyzer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}