{"product_id":"bently-nevada-133434-01-3500-50m-tachometer-i-o-module","title":"Bently Nevada 133434-01 3500\/50M Tachometer I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 133434-01\u003c\/strong\u003e is a 3500\/50M Tachometer I\/O Module designed for external terminations within the Bently Nevada 3500 Monitoring System. The \u003cstrong\u003e133434-01\u003c\/strong\u003e interfaces with the 3500\/50M Tachometer main board to process input signals from up to two proximity probes or magnetic pickups to determine shaft rotative speed, rotor acceleration, or rotor direction. It routes transducer inputs, buffered transducer signals, and proportional 4 to 20 mA recorder outputs to External Termination (ET) Blocks via dedicated cabling.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Termination Interface:\u003c\/strong\u003e Connects to external termination blocks via dedicated signal cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Channel Support:\u003c\/strong\u003e Handles inputs from up to two proximity transducers or magnetic pickups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProportional Analog Outputs:\u003c\/strong\u003e Provides individual +4 to +20 mA recorder outputs proportional to full-scale speed or acceleration ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuffered Signal Routing:\u003c\/strong\u003e Routes buffered transducer signals to external termination points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear-Slot Installation:\u003c\/strong\u003e Mounts in 1 full-height rear slot of the 3500 system rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbomachinery rotative speed monitoring\u003c\/li\u003e\n\u003cli\u003eRotor acceleration and speed band measurement\u003c\/li\u003e\n\u003cli\u003eReverse rotation detection and zero speed notification\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery monitoring requiring external terminal wiring configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number \/ Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e133434-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/50-02-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/50M Tachometer Module with I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125808-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTachometer ET Block (Euro Style connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e128015-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTachometer ET Block (Terminal Strip connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e128702-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecorder ET Block (Euro Style connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e128710-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecorder ET Block (Terminal Strip connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e135101-AAAA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500 Tachometer Signal to ET Block Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e129529-AAAA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500 Recorder Output to ET Block Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133434-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTachometer I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10.0 V to -24.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 k Ohm (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc, 40 mA maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA (Load resistance 0 to 600 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the I\/O module in 1 full-height rear slot corresponding directly to the slot containing the 3500\/50M Tachometer Monitor Module on the front of the rack.\u003c\/li\u003e\n\u003cli\u003eWhen using External Termination I\/O modules, External Termination Blocks and signal cables must be ordered separately.\u003c\/li\u003e\n\u003cli\u003eExternal Termination Blocks cannot be used with Internal Termination I\/O modules.\u003c\/li\u003e\n\u003cli\u003eUse Bussed External Termination Blocks with TMR I\/O modules only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards: EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; Standard: EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e Cables EFUP designation of 15 years per SJ\/T 11364-2024\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Condition of Classification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus (Non-barrier options):\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (Non-barrier options):\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666859487595,"sku":"133434-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133434-01-tachometer-i-o-module-3c3j5gb4y0p_3594324a-d219-4a55-8f2d-09f7aa724d67.jpg?v=1765449258","url":"https:\/\/www.plcprotech.com\/cs\/products\/bently-nevada-133434-01-3500-50m-tachometer-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}