{"product_id":"bently-nevada-200350-00-00-00-accelerometer","title":"Bently Nevada 200350-00-00-00 Accelerometer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 200350-00-00-00 \u003c\/strong\u003e general-purpose, case-mounted seismic transducer is designed for use with the Trendmaster Pro Constant Current Direct Input Card (part number \u003cstrong\u003e149811-02\u003c\/strong\u003e) and the Seismic Direct Input Card (part number 164746-01). The 200350-00-00-00  contains a piezoelectric sensing element in a ceramic shear geometry, generating a charge when subjected to vibration that is converted electronically to a differential voltage signal proportional to acceleration parallel to the sensitive axis. Encapsulated in a hermetically sealed stainless steel casing, it provides a differential voltage output across a top-mounted 2-pin MIL-C-5015 connector for machinery casing vibration monitoring in harsh industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral-purpose piezoelectric accelerometer with ceramic shear sensing geometry\u003c\/li\u003e\n\u003cli\u003eHermetically sealed stainless steel housing\u003c\/li\u003e\n\u003cli\u003eTop-mounted 2-pin MIL-C-5015 electrical connector\u003c\/li\u003e\n\u003cli\u003eBase 1\/4-28 threaded hole for versatile mounting options\u003c\/li\u003e\n\u003cli\u003eDirect interface to Trendmaster Pro Constant Current Direct Input Card and Seismic Direct Input Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCasing vibration monitoring on rotating and reciprocating machinery\u003c\/li\u003e\n\u003cli\u003eRotor vibration monitoring via machine bearing housings or outer casings\u003c\/li\u003e\n\u003cli\u003eIntegration into Trendmaster Pro condition monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrdering Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e200350-AA-BB-CC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 SS w\/ Brass tip, 0.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g +\/- 20% (10.2 mV\/m\/s^2 +\/- 20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g +\/- 20% (10.2 mV\/m\/s^2 +\/- 20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range (+\/- 3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 to 600,000 cpm (0.5 to 10,000 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude Linearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounted Resonant Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 kcpm (25 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBroadband Electrical Noise (1-10kHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 ug (3,434 um\/s^2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Bias Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 to 12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExcitation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 to 28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstant Current Excitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSettling Time (within 1% of bias)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 150 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDischarge Time Constant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Isolation (Case)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10^8 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-65 degF to +250 degF (-54 degC to +121 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Survivability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 g pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% relative, condensing, non-submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic Shear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel (Welded Hermetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Pin MIL-C-5015 Top Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHex Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11\/16 in (18 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.65 in (41.9 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 oz (51 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 Female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Torque (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 to 5 ft-lb (2.7 to 6.8 N-m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIGNAL \/ POWER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGROUND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Location:\u003c\/strong\u003e Install directly on the machine bearing housing or machine casing to maintain amplitude and frequency response accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Spec:\u003c\/strong\u003e Apply maximum mounting torque between 2 to 5 ft-lb (2.7 to 6.8 N-m) for proper coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcitation Warning:\u003c\/strong\u003e Do not use sensor part number 200350 for negative excitation voltage (-Vex).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Standard connection utilizes 22 AWG 2-conductor twisted shielded pair cables with a 2-socket moisture-resistant connector. Maximum recommended cable length is 104 ft (31 m) under standard dynamic load assumptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of FCC Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Directive 2014\/34\/EU (EN 60079-0, EN 60079-7, EN 60079-11, EN 60079-15)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA\/NRTL\/C:\u003c\/strong\u003e Intrinsically Safe Class I, Div 1, Groups A, B, C, D; Non-Incendive Class I, Div 2, Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Zone 0\/1 Ex ia IIC T4 Ga, Zone 2 Ex nA IIC T4 Gc \/ Ex ec IIC T4 Gc\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666629325163,"sku":"200350-00-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-200350-00-00-accelerometers-w3ri4txolw0_acae08f6-b627-47d4-b1e3-7fd425088f78.jpg?v=1765444376","url":"https:\/\/www.plcprotech.com\/cs\/products\/bently-nevada-200350-00-00-00-accelerometer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}