{"product_id":"emerson-se5009-deltav-s-series-dc-dc-system-power-supply","title":"Emerson SE5009 DeltaV S-series DC\/DC System Power Supply","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson SE5009\u003c\/strong\u003e is a modular \u003cstrong\u003e24VDC system power supply\u003c\/strong\u003e designed for the \u003cstrong\u003eDeltaV S-series\u003c\/strong\u003e distributed control platform. Connecting directly to 24 VDC plant bulk power, the unit provides localized system power to DeltaV controllers and associated I\/O interfaces without requiring external cabling. The module fits into DeltaV power\/controller carriers to energize internal power buses, delivering 5 VDC power to the controller and up to 8.0 A of 12 VDC power to the I\/O subsystem. Featuring load-sharing and modular expansion, the \u003cstrong\u003eSE5009\u003c\/strong\u003e supports system redundancy and maintains steady output power under varying input voltage conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePlugs directly into DeltaV S-series power\/controller carriers via internal power bus connections\u003c\/li\u003e\n\u003cli\u003eAccepts a +\/- 20% variance on 24 VDC input power while delivering regulated output\u003c\/li\u003e\n\u003cli\u003eDelivers up to 8.0 A at 12 VDC to the I\/O interface local bus and up to 2.0 A at 5 VDC to the controller\u003c\/li\u003e\n\u003cli\u003eSupports load-sharing and 1-to-N system power redundancy\u003c\/li\u003e\n\u003cli\u003eFeatures complete electrical isolation between system power and field power\u003c\/li\u003e\n\u003cli\u003eOnboard LED indicators display DC input status and output fault detection\u003c\/li\u003e\n\u003cli\u003eIntegrated normally open alarm relay output changes status upon input or power supply failure\u003c\/li\u003e\n\u003cli\u003eInternally fused input protection with soft-start inrush current limiting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDeltaV S-series control system power distribution\u003c\/li\u003e\n\u003cli\u003eDistributed control system (DCS) process automation cabinets\u003c\/li\u003e\n\u003cli\u003eSystem power redundancy for continuous process industries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e24VDC System Power Supply\u003c\/td\u003e\n\u003ctd\u003eSE5009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSE5009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeltaV S-series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC to DC System Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/- 20% at 6.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A peak maximum for 5 ms over 24 VDC input range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power Rating (-40 to 60 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 VDC at 8.0 A, +5 VDC at 2.0 A (10 W total combined +5 VDC outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power Rating (60 to 70 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 VDC at 6.0 A, +5 VDC at 2.0 A (10 W total combined +5 VDC outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternally fused, non-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput protected at 110% to 120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHold-up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput remains within 5% of nominal at full load and minimum input for 5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 60 degC (-40 to 140 degF) without derating; 60 to 70 degC (140 to 158 degF) with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC (-40 to 158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirborne Contaminants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 airborne contaminants class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 g 1\/2-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak from 5 Hz to 13.2 Hz, 0.7 g from 13.2 Hz to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEither slot of 2-wide power\/controller carrier, power slot of VerticalPlus 4-wide carrier, any slot of 4-wide power carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Prerequisites\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeltaV v11.3 or later; compatible with S-series Horizontal carriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Power\u003c\/td\u003e\n\u003ctd\u003eDC input, 2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Contact\u003c\/td\u003e\n\u003ctd\u003e2-wire normally open relay (2.0 A at 30 VDC, 2.0 A at 250 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the DeltaV S-series power\/controller carrier onto a standard T-type DIN rail.\u003c\/li\u003e\n\u003cli\u003ePlug the power supply module securely into an appropriate power supply slot on the carrier.\u003c\/li\u003e\n\u003cli\u003eConnect the primary 24 VDC input wiring to the S-series carrier power terminals.\u003c\/li\u003e\n\u003cli\u003eConnect the 2-wire alarm contact terminals to monitoring devices for power status relay switching.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate enclosure airflow to manage thermal conditions when operating near ambient temperature limits.\u003c\/li\u003e\n\u003cli\u003eFollow Class 1 Division 2 (12P5402) or Zone 2 (12P5404) installation instructions when deploying in hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e EMC-EN 61326-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM:\u003c\/strong\u003e Class I, Division 2, Groups A, B, C, D, T4 (Standards FM 3600, FM 3611)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecFM:\u003c\/strong\u003e Class I, Division 2, Groups A, B, C, D, T4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA-C22.2 No. 213-M1987, CSA-C22.2 No. 1010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e II 3G Ex nA IIC T4 Gc (Standards ATEX 94\/9\/EC, EN 60079-0, EN 60079-15)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC-Ex:\u003c\/strong\u003e II 3G Ex nA IIC T4 Gc (Standards EN 60079-0, EN 60079-15)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine:\u003c\/strong\u003e IACS E10, ABS Certificate of Design Assessment, DNV-GL Marine Certificate\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53634624455019,"sku":"SE5009","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/SE5009-001.jpg?v=1785470146","url":"https:\/\/www.plcprotech.com\/cs\/products\/emerson-se5009-deltav-s-series-dc-dc-system-power-supply","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}