{"product_id":"ge-multilin-c60-k03-hkh-f8l-h67-m67-p6d-breaker-protection-system","title":"GE Multilin C60-K03-HKH-F8L-H67-M67-P6D Breaker Protection System","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin C60-K03-HKH-F8L-H67-M67-P6D\u003c\/strong\u003e is a substation-hardened breaker protection system designed for the integrated protection, control, and monitoring of circuit breakers. Part of the Universal Relay (UR) family, the \u003cstrong\u003eGE Multilin C60-K03-HKH-F8L-H67-M67-P6D\u003c\/strong\u003e supports complex dual-breaker busbar configurations including breaker-and-a-half and ring bus arrangements. It features advanced automation capabilities via programmable logic engine (FlexLogic) and provides comprehensive digital I\/O options alongside high-speed peer-to-peer communication. The device integrates high-accuracy AC metering, fault disturbance recording, and advanced IEC 61850 protocol support, making it suitable for direct integration into DCS and SCADA systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete protection, control, and monitoring for single and dual breaker schemes in a single platform.\u003c\/li\u003e\n\u003cli\u003eHigh-speed peer-to-peer communication for inter-device messaging and trip\/close commands.\u003c\/li\u003e\n\u003cli\u003eIntegrated 7-inch color graphic HMI with bay mimic, annunciator functionality, and graphical phasor displays.\u003c\/li\u003e\n\u003cli\u003ePowerful FlexLogic engine with up to 1024 lines of programmable logic for custom control automation.\u003c\/li\u003e\n\u003cli\u003eComprehensive protection functions including breaker failure, synchrocheck, multi-shot autoreclose, directional power, and overcurrent\/thermal elements.\u003c\/li\u003e\n\u003cli\u003eAdvanced IEC 61850 Ed. 1 and Ed. 2 implementation, routable GOOSE (R-GOOSE), and PRP zero-failover redundancy support.\u003c\/li\u003e\n\u003cli\u003eContinuous device health diagnostics monitoring internal hardware and CT\/VT circuitry.\u003c\/li\u003e\n\u003cli\u003eHigh-capacity disturbance recording including 1024 SOE events, COMTRADE waveform capture, and data logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStand-alone circuit breaker monitoring and control.\u003c\/li\u003e\n\u003cli\u003eBreaker-and-a-half and ring bus multiple breaker configuration management.\u003c\/li\u003e\n\u003cli\u003eAutomatic bus transfer schemes (main-tie-main) using a single device.\u003c\/li\u003e\n\u003cli\u003eSubstation automation and distributed bay control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrdering Code Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC60\u003c\/td\u003e\n\u003ctd\u003eBreaker Protection System Base Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCPU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003eRS485 + two 100BaseFX Eth, Multimode ST + one 10\/100BaseT Eth, RJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eEthernet Global Data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eHorizontal (19\" rack) - Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKH\u003c\/td\u003e\n\u003ctd\u003eEnhanced English Front Panel with User-Programmable Pushbuttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003e125\/250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCT\/VT DSP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8L\u003c\/td\u003e\n\u003ctd\u003eSensitive Ground 4CT\/4VT w\/ enhanced diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital I\/O Slot H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eH67\u003c\/td\u003e\n\u003ctd\u003e8 Form-A (No Monitoring) Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital I\/O Slot M\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM67\u003c\/td\u003e\n\u003ctd\u003e8 Form-A (No Monitoring) Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital I\/O Slot P\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP6D\u003c\/td\u003e\n\u003ctd\u003e16 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Grid Solutions (GE Multilin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125\/250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCT\/VT Input Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensitive Ground 4CT\/4VT with enhanced diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForm-A Outputs (Slot H and Slot M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Inputs (Slot P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch color graphic HMI with pushbuttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\/TCP, DNP 3.0, IEC 61850 Ed. 1\/Ed. 2, IEC 60870-5-103\/104, EGD, HTTP, SFTP, MMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588, SNTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvent Recorder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1024 time-stamped events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOscillography\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE C37.111-1999\/2013, IEC 60255-24 COMTRADE (64 digital, up to 40 analog channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure proper panel cutouts for standard 19-inch rack horizontal installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Solidly ground the relay frame to the main station ground bus using the dedicated grounding terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect CT and VT secondary circuits securely using verified terminal wiring diagrams. Ensure polarity alignment for directional power and overcurrent elements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Connect Ethernet networks using multimode ST fiber cables for 100BaseFX connections or RJ-45 copper cables for 10\/100BaseT connections. Maintain shield integrity on RS485 serial buses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Verify control voltage matches the 125\/250 V AC\/DC rating before applying power to the terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53647866757483,"sku":"C60-K03-HKH-F8L-H67-M67-P6D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/C60-K03-HKH-F8L-H67-M67-P6D.jpg?v=1785635083","url":"https:\/\/www.plcprotech.com\/cs\/products\/ge-multilin-c60-k03-hkh-f8l-h67-m67-p6d-breaker-protection-system","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}