{"product_id":"yokogawa-afv30s-s41251-hku-centum-vp-field-control-unit","title":"Yokogawa AFV30S-S41251\/HKU CENTUM VP Field Control Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AFV30S-S41251\/HKU\u003c\/strong\u003e is a 19-inch rack-mountable Field Control Unit (FCU) designed as the core component of the control function within the CENTUM VP integrated production control system. It processes process operations, manages field communications over dual-redundant Vnet\/IP networks, and handles local and remote I\/O data through FIO interface configurations.\u003c\/p\u003e\n\u003cp\u003eThis single-processor module platform supports up to 8 I\/O modules directly on the rack assembly and connects to up to 13 ESB bus or optical ESB bus node units. Equipped with dual-redundant power supply modules operating at 220-240 V AC, this unit incorporates an integrated House Keeping Unit interface (\/HKU option) that outputs FCU fault contacts, monitors cabinet environmental conditions via the HK bus and optical ESB bus, and displays system alarms directly on the Human Interface Station (HIS).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eServes as the central control processing unit for CENTUM VP Field Control Stations\u003c\/li\u003e\n\u003cli\u003eFeatures dual-redundant Vnet\/IP communication interfaces for high-reliability network integration\u003c\/li\u003e\n\u003cli\u003eConfigured with dual-redundant power supply modules for continuous operation\u003c\/li\u003e\n\u003cli\u003eAccommodates up to 8 I\/O modules and supports up to 13 connectable ESB\/optical ESB node units\u003c\/li\u003e\n\u003cli\u003eIntegrated House Keeping Unit (\/HKU) interface for cabinet environmental monitoring and fault contact outputs\u003c\/li\u003e\n\u003cli\u003eIncludes battery backup capable of maintaining main memory for up to 72 hours during power outages\u003c\/li\u003e\n\u003cli\u003eStandard 19-inch rack-mountable form factor with 8-hole M5 mounting points\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess automation and control in CENTUM VP integrated production control systems\u003c\/li\u003e\n\u003cli\u003eCentralized field control interfacing with remote FIO nodes over optical ESB and ESB buses\u003c\/li\u003e\n\u003cli\u003eReal-time monitoring and fault diagnostic reporting via House Keeping Unit (HKU) networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel \/ Suffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFV30S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003ctd\u003eField Control Unit (for FIO, 19-inch Rack Mountable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003ctd\u003eStandard type (for CP461)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP, dual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003ctd\u003eAlways 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003ctd\u003eControl function for field control station (LFS1700)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\/HKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith HKU interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFV30S-S41251\/HKU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField Control Unit (19-inch Rack Mountable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply, 220-240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable Node Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 13 (Total ESB Bus ANB10 and Optical ESB Bus ANB11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery backup for main memory: Max. 72 hours (Recharge time: Min. 48 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eREADY Contact Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 terminals (NC, C), 30 V DC, max. 0.3 A (Opens during FCU failure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mounting (M5 x 8 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 7.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eREADY Contact Output Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminal connection (NC, C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnect UTP cable (CAT5e or better) to Layer 2 switch for Vnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHKU Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCabinet environment monitoring, HK bus connection, and FCU fault contact output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Mounting:\u003c\/strong\u003e Mount the unit on a standard 19-inch rack using M5x8 screws and the provided accessory insulating bushes (part number S9049PM).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Enclosure Requirements:\u003c\/strong\u003e To meet safety standards and EMC requirements, install the control unit inside a keyed metallic cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESB Bus Coupler Modules:\u003c\/strong\u003e Install ESB Bus Coupler Modules (EC401 or EC402) in slots 7 and 8 of the FCU to connect node units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical ESB Bus Repeater Master Modules:\u003c\/strong\u003e When connecting remote nodes over optical fiber, install Optical ESB Bus Repeater Master Modules (ANT401 or ANT411) in pairs within slots 1 through 6, ordered from right to left.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety Partitioning:\u003c\/strong\u003e When using I\/O modules with built-in barriers inside the unit, an insulating partition kit (Part No. T9083ND) must be installed.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53644153127275,"sku":"AFV30S-S41251\/HKU","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/AFV30S.jpg?v=1785592722","url":"https:\/\/www.plcprotech.com\/cs\/products\/yokogawa-afv30s-s41251-hku-centum-vp-field-control-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}