{"title":"B\u0026R X20 System","description":"\u003cp\u003e\u003cstrong\u003eB\u0026amp;R X20 System distributed control and I\/O topology.\u003c\/strong\u003e Built on a unique 3-part modular architecture (terminal block, electronic module, and bus module), the X20 series enables toolless pre-wiring and full hot-swapping under power to minimize machinery downtime. It delivers dense packaging with up to 12 channels per 12.5 mm slice, drastically reducing control cabinet footprint. Operating over deterministic networks including POWERLINK, EtherCAT, and Modbus TCP, the system yields microsecond-level synchronization while seamlessly integrating standard I\/O, specialized motion technology, and functional safety via openSAFETY into a unified automation platform.\u003c\/p\u003e","products":[{"product_id":"b-r-x20bm11-x20-bus-module","title":"B\u0026R X20BM11 X20 Busmodul","description":"\u003ch3\u003eBeschreibung\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20BM11\u003c\/strong\u003e ist ein spezialisiertes \u003cstrong\u003eX20-Busmodul\u003c\/strong\u003e, das als Basis für X20 I\/O-Module dient und die interne Rückplattenverbindung sowie die Verteilung der internen I\/O-Stromversorgung herstellt. Dieses Modul verfügt über einen 24 VDC mechanischen Kodierungsmechanismus, um eine falsche Moduleinführung zu verhindern und die Hardwarekompatibilität innerhalb der Systemkonfiguration sicherzustellen. Es bietet eine kontinuierliche interne I\/O-Versorgung über die Rückplatte und ermöglicht eine nahtlose Strom- und Datenverteilung an benachbarte Module. Die Einheit ist für platzbeschränkte industrielle Steuerungsschränke optimiert und nutzt ein kompaktes Format zur Maximierung der Dichte. Es integriert sich direkt in standardmäßige B\u0026amp;R X20-Steuerungssysteme und bedient Hochleistungsmaschinen, Fabrikautomation und Prozessanlagen, die eine zuverlässige modulare Verteilung erfordern.\u003c\/p\u003e\n\u003ch3\u003eEigenschaften\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegriert den standardmäßigen X20-Rückplane-Bus für die interne Datenleitung.\u003c\/li\u003e\n\u003cli\u003eVerfügt über ein 24 VDC mechanisches Kodierungssystem zum Schutz der Hardware vor falscher Modulinstallation.\u003c\/li\u003e\n\u003cli\u003eBietet eine kontinuierliche interne I\/O-Versorgungsverteilung entlang der Systemschiene.\u003c\/li\u003e\n\u003cli\u003eKompakte Bauweise mit präzisem 12,5 mm Rastermaß zur Unterstützung von hochdichten Schalttafeln.\u003c\/li\u003e\n\u003cli\u003eNiedriger Stromverbrauch vom Bus zur Aufrechterhaltung der Systemeffizienz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAnwendungen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZentrale und verteilte I\/O-Topologien in der Fabrikautomation.\u003c\/li\u003e\n\u003cli\u003eMaschinensteuerungssysteme mit modularer I\/O-Erweiterung.\u003c\/li\u003e\n\u003cli\u003eProzesssteuerungsinfrastruktur und Montageablaufsteuerung.\u003c\/li\u003e\n\u003cli\u003eStromverteilung und Signaltrennung innerhalb der X20-Steuerungsschränke.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Spezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eHersteller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eProduktnummer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eX20BM11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eProduktart\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eX20 Busmodul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eNennspannung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eLeistungsaufnahme (Bus)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0,13 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eZulässige Kontaktbelastung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eRastermaß\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e12,5+0,2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eInterne I\/O-Versorgung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eKontinuierlich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eKodierung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e24 VDC kodiert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eÖsterreich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eAbmessungen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e12,5 mm Breite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMontagerichtlinien\u003c\/h3\u003e\n\u003ch4\u003eDIN-Schienenmontage\u003c\/h4\u003e\n\u003cp\u003eMontieren Sie das Busmodul vertikal oder horizontal auf einer standardmäßigen 35 mm DIN-Schiene. Stellen Sie sicher, dass das Modul sicher in die Schienenführung einrastet, bevor Sie elektronische I\/O-Module montieren.\u003c\/p\u003e\n\u003ch4\u003eInterne I\/O-Versorgung und Kodierung\u003c\/h4\u003e\n\u003cp\u003eÜberprüfen Sie, ob die 24 VDC-Codierung mit dem einzusetzenden Elektronikmodul übereinstimmt. Die durchgehende interne Versorgung überträgt die Leistung über die Backplane-Kontakte; prüfen Sie vor dem Einsetzen die Ausrichtstifte, um Beschädigungen der Anschlüsse zu vermeiden.\u003c\/p\u003e\n\u003ch4\u003eKühlung und Belüftung\u003c\/h4\u003e\n\u003cp\u003eHalten Sie die empfohlenen Abstände oberhalb und unterhalb des X20-Modulgestells ein, um eine natürliche Konvektionskühlung zu ermöglichen. Vermeiden Sie es, Wärmequellen mit hoher Verlustleistung direkt unter dem Modularray zu platzieren.\u003c\/p\u003e\n\u003ch3\u003eHäufig gestellte Fragen\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist die Hauptfunktion dieser Hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEs dient als strukturelle Basis und elektrischer Backplane-Anschluss für das X20 I\/O-System und ermöglicht die Datenübertragung sowie die Stromverteilung zwischen den Modulen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsoliert dieses Basismodul die I\/O-Stromversorgung?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein, es stellt eine durchgehende interne I\/O-Versorgungsverbindung über die Busstation bereit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas bedeutet die 24 VDC-Codierspezifikation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas bedeutet, dass das Modul eine mechanische Codierung besitzt, die nur X20-Elektronikmodule für den Betrieb mit 24 VDC akzeptiert und so Spannungsfehler verhindert.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie hoch ist die maximale Kontaktbelastbarkeit für den internen Bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie zulässige Kontaktbelastung ist mit maximal 10 A angegeben.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie viel Leistung zieht die Einheit vom Bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul hat einen internen Bus-Stromverbrauch von 0,13 W.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie groß ist das genaue Rastermaß der Einheit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer Rastermaß beträgt 12,5 mm mit einer Toleranz von +0,2 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann diese Einheit im laufenden Betrieb ausgetauscht werden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Hot-Swap-Fähigkeiten hängen von der spezifischen Konfiguration des Haupt-X20-Controllers und des darin eingesetzten elektronischen Moduls ab; siehe vor dem Entfernen das Systemhandbuch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenötigt das Modul eine eigenständige Softwarekonfiguration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein, es fungiert als passiver physischer und elektrischer Backplane-Link und benötigt keine eigenständige Firmware-Konfiguration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie wird das Modul am Schaltschrank befestigt?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEs wird direkt auf eine standardmäßige 35 mm DIN-Schiene aufgeklickt und verriegelt sich seitlich mit benachbarten X20-Busmodulen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas passiert, wenn ein Modul mit einer anderen Spannungsbewertung eingesetzt wird?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer mechanische Codiermechanismus verhindert physisch das Einsetzen von Modulen, die nicht der 24 VDC-Konfiguration entsprechen.\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086365843819,"sku":"X20BM11","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20bm11-buhjao14ufz.png?v=1776138142"},{"product_id":"b-r-x20di4371-x20-digital-counter-and-input-module","title":"B\u0026R X20DI4371 X20 Digitalzähler- und Eingangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20DI4371 (X20 DI 4371)\u003c\/strong\u003e ist ein hochpräzises Digital-Eingangsmodul aus der X20-Automatisierungsserie, das sowohl für Standard-Digital-Eingangsaufgaben als auch für Hochgeschwindigkeits-Zählerfunktionen entwickelt wurde. Mit 4 digitalen Eingängen für 24 VDC ist dieses Modul für 3-Draht-Anschlussarchitekturen optimiert, was eine zuverlässige Integration von Näherungssensoren, Encodern und anderen industriellen Feldgeräten ermöglicht. Durch die Bereitstellung von Hochgeschwindigkeits-Signalverarbeitung und Zählfunktionen dient der X20DI4371 als entscheidende Komponente in Anwendungen von präziser Geschwindigkeitsüberwachung und Längenmessung bis hin zur ereignisbasierten Chargenzählung und gewährleistet Datenpräzision in Hochgeschwindigkeits-Produktionsumgebungen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas Modul ist für eine nahtlose Integration in das X20-System ausgelegt und erfordert nur minimale Konfiguration, um mit der Signalerfassung zu beginnen. Es verwendet eine robuste Eingangsschaltung, die einen weiten Spannungsbereich von 24 VDC -15 % \/ +20 % unterstützt und eine hervorragende Widerstandsfähigkeit gegen Spannungsschwankungen bietet, wie sie häufig in großflächigen Maschinensteuerungsschränken auftreten. Der X20DI4371 bietet Echtzeit-Diagnosetransparenz durch seine dedizierten Statusanzeigen, die I\/O-Funktion, Betriebszustand und Modulstatus anzeigen. Dieses Diagnoseset ermöglicht es Wartungstechnikern, Sensorfehler oder Signalabweichungen sofort zu erkennen und dadurch die Fehlersuche während des Maschinenbetriebs erheblich zu verkürzen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20DI4371\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eDigitaleingänge\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eNennspannung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eEingangsspannungsbereich\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e24 VDC (-15 % \/ +20 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eAnschlusstyp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e3-Draht\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eBus-Stromaufnahme\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0,14 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInterne I\/O-Leistung\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e0,59 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eSchutzart\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIst der X20DI4371 in der Lage, Hochgeschwindigkeitspulse zu zählen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, dieses Modul ist als digitales Zählermodul ausgelegt. Es ist dafür konzipiert, hochfrequente Pulsfolgen zu verarbeiten, was es für Anwendungen geeignet macht, die eine genaue Zählung oder Geschwindigkeitsmessung von Encodern und Durchflussmessern erfordern.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann ich 2-Draht-Sensoren mit diesem Modul verwenden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul ist für 3-Draht-Anschlüsse optimiert. Während einige 2-Draht-Konfigurationen je nach Leckstrom und Schaltschwelle des Sensors funktionieren können, wird eine 3-Draht-Verbindung empfohlen, um eine zuverlässige Signaldetektion sicherzustellen und mögliche Probleme durch Ruheströme zu vermeiden.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelche Diagnoseinformationen sind am Modul verfügbar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul verfügt über integrierte LEDs, die eine visuelle Rückmeldung zur I\/O-Funktion jedes Kanals, zum aktuellen Betriebszustand und zum Gesamtstatus des Moduls geben, was eine schnelle Vor-Ort-Diagnose ermöglicht.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerdrahtung und Abschirmung:\u003c\/strong\u003e Aufgrund der Zählerfrequenzfähigkeiten dieses Moduls sollten stets abgeschirmte Kabel für die Signalübertragung verwendet werden. Die Abschirmung ist ordnungsgemäß an die gemeinsame Erdungsschiene des Schaltschranks anzuschließen, um Störspannungen zu vermeiden, was besonders wichtig ist, wenn Pulse mit hoher Geschwindigkeit gezählt werden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStabilität der Stromversorgung:\u003c\/strong\u003e Obwohl das Modul eine Spannungstoleranz von -15 % \/ +20 % aufweist, sollte Ihre 24 VDC-Stromversorgung gut gefiltert sein, um Ripple-Spannungen zu minimieren. Hohe Ripple können zu Fehlzählungen oder unregelmäßigem Verhalten in empfindlichen Eingangsstufen führen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKabelverlegung:\u003c\/strong\u003e Halten Sie die Eingangssignalverkabelung physisch getrennt von Hochspannungs-Wechselstromleitungen und Motorantriebskabeln. Induktionen durch stromstarke Schaltgeräte können Störspannungen in die Eingangssignale einbringen, was zu Zählungenauigkeiten führt.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086365942123,"sku":"X20DI4371","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20di4371-ookwk2og2a3.png?v=1776138180"},{"product_id":"b-r-x20bm33-bus-module-for-safeio","title":"B\u0026R X20BM33 Busmodul für SafeIO","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20BM33 (X20 BM 33)\u003c\/strong\u003e ist ein spezielles Busmodul, das speziell für die X20 SafeIO Modulserie entwickelt wurde. Es dient als physikalische und elektrische Grundlage für sicherheitskritische I\/O-Konfigurationen und ermöglicht sowohl die X2X Link-Kommunikation als auch die Verteilung der internen I\/O-Versorgungsspannung. In anspruchsvollen Industrieumgebungen wie automatisierten Montagezellen, kollaborativen Robotern und Pressensicherheitssystemen gewährleistet das X20BM33 die mechanische Integrität und elektrische Kontinuität, die für die sicherheitsorientierte Automatisierung von B\u0026amp;R erforderlich sind. Durch die Bereitstellung einer stabilen Verbindungsbasis für SafeIO-Module hilft es, intermittierende Kontaktfehler zu vermeiden, die unerwünschte Sicherheitsstopps auslösen könnten, und trägt so zur Aufrechterhaltung der Produktivität bei gleichzeitiger Sicherstellung von Maschinen- und Personensicherheit bei.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas X20BM33 wurde für die X20-Plattform entwickelt und fungiert als Backplane für den sicheren I\/O-Einsatz. Ein zentrales Merkmal dieses Busmoduls ist die interne I\/O-Versorgungsspannungsanbindung, die eine effiziente Stromverteilung über die SafeIO-Modulkette ermöglicht. Es ist für eine Nennspannung von 24 VDC ausgelegt und unterstützt eine hohe zulässige Kontaktbelastung von 10 A, um den erhöhten Leistungsanforderungen von Sicherheitssensoren und Aktoren gerecht zu werden. Das Modul unterstützt sowohl horizontale als auch vertikale Montageorientierungen, was Flexibilität bei der Schaltschrankgestaltung bietet, und ist für den Betrieb in Höhen bis zu 2000 m ohne Leistungsminderung ausgelegt.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20BM33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAnwendung\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eX20 SafeIO Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eStromversorgung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eInterne I\/O-Versorgungsspannung angeschlossen über\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eNennspannung\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eZulässige Kontaktbelastung\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eBus-Stromaufnahme\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0,13 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eSchutzart\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e2,0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIst das X20BM33 mit Standard-X20-Digitalmodulen kompatibel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas X20BM33 ist speziell für X20 SafeIO-Module optimiert. Obwohl es physisch auch andere Module aufnehmen kann, sollten Sie stets die B\u0026amp;R-Dokumentation für Ihre spezifische Modulserie konsultieren, um die Kompatibilität mit der SafeIO-Stromversorgungsarchitektur sicherzustellen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelche Funktion hat die 10-A-Kontaktbelastung?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie 10-A-Belastbarkeit ermöglicht es dem Busmodul, einen erheblichen Strom zu nachgeschalteten Modulen zu führen, ohne zu überhitzen oder Spannungsabfall zu verursachen. Dies ist besonders wichtig beim Betrieb von Sicherheits-Sensorketten oder sicherheitsrelevanten Ausgangsgeräten mit hohem Stromverbrauch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGibt es spezielle Umgebungsbeschränkungen für dieses Busmodul?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul ist mit Schutzart IP20 bewertet und unterstützt den Betrieb bis zu einer Höhe von 2000 m ohne Einschränkungen. Stellen Sie sicher, dass die Umgebung im Schaltschrank kontrolliert wird, um das Eindringen von Feuchtigkeit oder Staub zu verhindern, da diese die Zuverlässigkeit der physischen Kontakte auf der Bus-Backplane beeinträchtigen können.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanische Befestigung:\u003c\/strong\u003e Beim Aufstecken des Moduls auf die DIN-Schiene stellen Sie sicher, dass es fest eingerastet ist. Eine korrekte Ausrichtung mit benachbarten Modulen ist entscheidend, um die Integrität des X2X Link-Busses und der internen Stromversorgungsbrücke zu gewährleisten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStromverteilung:\u003c\/strong\u003e Bei der Berechnung der Gesamtlast Ihres Sicherheitsracks stellen Sie sicher, dass die kumulative Stromaufnahme aller SafeIO-Module die zulässige Kontaktbelastung von 10 A des X20BM33 nicht überschreitet. Verwenden Sie bei Bedarf redundante Stromversorgungen, wenn Ihre Sicherheitsarchitektur eine hohe Leistung für verteilte Feld-Sicherheitsgeräte erfordert.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSicherheitskonformität:\u003c\/strong\u003e Vergewissern Sie sich stets, dass die SafeIO-Module korrekt im X20BM33 eingerastet sind, bevor Sie das System einschalten. Die physikalische Verbindung dient nicht nur der Stromversorgung, sondern ermöglicht auch die sicherheitsrelevante Konfiguration der Modulkette; lose Verbindungen können zu sicherheitsrelevanten Fehlern oder Systemabschaltungen führen.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366007659,"sku":"X20BM33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20bm33-rvgo4axkrbk.png?v=1776138147"},{"product_id":"b-r-x20ds4389-digital-signal-module","title":"B\u0026R X20DS4389 Digitales Signalmudul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20DS4389 (X20 DS 4389)\u003c\/strong\u003e ist ein hochpräzises Digital-Signalprozessor-Modul, das für das B\u0026amp;R X20 Automatisierungssystem entwickelt wurde. Es ist für Anwendungen konzipiert, die extreme Geschwindigkeit und Mikrosekunden-Genauigkeit erfordern, und eignet sich ideal für Aufgaben wie die Erkennung von Passermarken, Pulslängenmessung und die Erzeugung von Hochgeschwindigkeits-Bewegungsabläufen. Durch die Entkopplung der Signalverarbeitung von der Standard-X2X-Link-Zykluszeit mittels integrierter Zeitstempel- und Oversampling-Technologie bietet es eine hochpräzise Steuerung in Hochgeschwindigkeitsfertigung, Montage und Verpackungsumgebungen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas X20DS4389 verfügt über eine sehr flexible I\/O-Architektur:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 dedizierte digitale Eingänge:\u003c\/strong\u003e Für 24 VDC Betrieb mit schneller Reaktionszeit ausgelegt.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 konfigurierbare Kanäle:\u003c\/strong\u003e Können unabhängig als digitale Eingänge oder Ausgänge eingestellt werden, um spezifische Anwendungsanforderungen zu erfüllen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetTime-Unterstützung:\u003c\/strong\u003e Integrierte Zeitstempelung mit 125 ns Auflösung, die eine präzise Ereignisverfolgung unabhängig von Buskommunikationslatenzen ermöglicht.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOversampling-Fähigkeit:\u003c\/strong\u003e Ermöglicht das Erfassen und Erzeugen von Signalmustern mit kürzeren Dauern als die X2X-Link-Zykluszeit (bis zu 25 µs Scanraten).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlankenerkennung:\u003c\/strong\u003e Jeder der 4 Einheiten unterstützt Pulslängen-\/Differenzzeitmessung und verfügt über Verlaufs-Puffer zur Ereignisprotokollierung.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20DS4389\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eDigitale Eingänge\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eKonfigurierbare I\/O\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eNennspannung\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eAusgangsstrom\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0,1 A pro Kanal (0,4 A gesamt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eZeitstempelauflösung\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e125 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eAbtastrate (Oversampling)\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e25 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e0,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eSchutzart\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas sind die Hauptanwendungsbereiche dieses Moduls in der Industrie?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas X20DS4389 wird in Automatisierungsaufgaben eingesetzt, die Hochgeschwindigkeitspräzision erfordern, wie z. B. Hochgeschwindigkeits-Sortierung, Passermarkenerkennung an Verpackungslinien und präzises Timing für Trommel-Sequenzer oder industrielle Aktuatoren.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie verbessert die Zeitstempelfunktion die Leistung?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie integrierte Zeitstempelfunktion zeichnet den genauen Zeitpunkt eines Eingangssignals mit 125 ns Auflösung auf. Dadurch kann der Controller auf Hochgeschwindigkeitsereignisse reagieren, die sonst möglicherweise übersehen würden oder durch „Jitter“ verursacht durch Standard-Buszyklus-Schwankungen beeinträchtigt wären.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSind Zubehörteile im Lieferumfang enthalten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein, für die Installation dieses Moduls werden das X20TB12 Anschlussklemmenmodul und das X20BM11 Busmodul benötigt. Diese müssen separat bestellt werden.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerdrahtung und Signalqualität:\u003c\/strong\u003e Aufgrund der Hochgeschwindigkeitsnatur der vom Modul verarbeiteten Signale (bis zu 40 kHz) sollten stets geschirmte Kabel verwendet werden. Halten Sie Signalleitungen getrennt von leistungsstarken AC- oder DC-Motorleitungen, um elektromagnetische Störungen und damit falsche Flankenerkennungen zu vermeiden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotentialausgleich:\u003c\/strong\u003e Die 24 VDC- und GND-Anschlüsse müssen stabil und zuverlässig sein. Stellen Sie sicher, dass die Sensor-\/Aktuatorversorgung sauber und stabil ist, da Störungen auf der Versorgungsleitung die hochpräzise Zeitmessung der NetTime-Funktionen beeinträchtigen können.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonfiguration:\u003c\/strong\u003e Nutzen Sie die B\u0026amp;R Software-Suite, um die Betriebsmodi (Oversampling, Flankenerkennung oder Zeitstempelung) entsprechend den Anforderungen der einzelnen Kanäle einzustellen. Achten Sie darauf, dass die Softwareeinstellungen mit den physischen Hardwareanschlüssen übereinstimmen, um Logikfehler zu vermeiden.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366073195,"sku":"X20DS4389","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ds4389-hmz4auadr24.png?v=1776138197"},{"product_id":"b-r-x20cp1483-x20-series-cpu","title":"B\u0026R X20CP1483 X20 Serie CPU","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20CP1483 (X20 CP 1483)\u003c\/strong\u003e ist ein leistungsstarkes CPU-Modul, das im B\u0026amp;R X20 Automatisierungs-Ökosystem eine zentrale Rolle spielt. Es wurde als Master-Prozessor für komplexe Maschinensteuerungsaufgaben entwickelt und steuert die Echtzeitkommunikation über POWERLINK- und Ethernet-Netzwerke. Der X20CP1483 ist für anspruchsvolle Industriebereiche konzipiert – darunter Hochgeschwindigkeitsverpackung, Automobilmontage und Präzisionsrobotik – in denen zuverlässige Zykluszeiten und hohe Rechenleistung erforderlich sind, um Ausfallzeiten zu minimieren. Sein kompaktes, modulares Design ermöglicht eine effiziente Integration in bestehende X20-Rückwände und bietet gleichzeitig die robuste Rechenleistung, die für anspruchsvolle Mehrachsen-Bewegungs- und Logiksteuerungen notwendig ist.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDie CPU-Architektur verfügt über ein hocheffizientes Energiemanagement mit einem Basisverbrauch von 6 W und einem internen I\/O-Verbrauch von 0,6 W. Sie unterstützt einen weiten Eingangsspannungsbereich von 24 VDC -15 % \/ +20 %, was einen stabilen Betrieb in Umgebungen mit variabler Netzstabilität gewährleistet. Das Modul beinhaltet umfassende Diagnose-Statusanzeigen zur Echtzeitüberwachung des CPU-Zustands, der Ethernet-\/POWERLINK-Netzwerkaktivität, des CompactFlash-Speicherstatus und des Batteriestands. Die flexible Schnittstellenunterstützung – einschließlich USB und optionaler Schnittstellenmodule – ermöglicht eine skalierbare Konfiguration für verschiedene anwendungsspezifische Anforderungen, von einfachen Logikaufgaben bis hin zu komplexer, datenintensiver industrieller Automatisierung.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20CP1483\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSerie\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eX20 CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eEingangsspannung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e24 VDC (-15 % \/ +20 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eMaximaler Eingangsstrom\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e2,2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eLeistungsaufnahme (Basis)\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eInterne I\/O-Leistung\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0,6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e2,0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eSchutzart\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWofür werden die Statusanzeigen im X20CP1483 verwendet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Statusanzeigen liefern wichtige Rückmeldungen zum Betriebszustand der CPU, zu den Ethernet- und POWERLINK-Kommunikationsverbindungen, zum Zustand der CompactFlash-Karte sowie zum Status der internen Backup-Batterie. Diese LEDs ermöglichen es Wartungsteams, Netzwerk- oder Hardwarefehler schnell zu diagnostizieren.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst die Speicherkarte oder das Schnittstellenmodul im Lieferumfang der CPU enthalten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein, die Leistungsangaben (6 W) beinhalten keine Speicherkarten, USB-Geräte oder Schnittstellenmodule. Diese Komponenten müssen entsprechend den spezifischen Speicher- und Konnektivitätsanforderungen Ihrer Anwendung separat beschafft werden.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelche Eingangsspannungsstabilität wird für diese CPU benötigt?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie CPU ist für den Betrieb im Bereich von 24 VDC -15 % \/ +20 % ausgelegt. Obwohl sie Standard-Schwankungen in industriellen Umgebungen gut verkraftet, sollte Ihre Stromversorgung eine saubere, geregelte 24 VDC liefern, um maximale Lebensdauer und stabile Verarbeitung zu gewährleisten.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem-Stromversorgung:\u003c\/strong\u003e Der X20CP1483 kann einen maximalen Eingangsstrom von 2,2 A ziehen. Stellen Sie sicher, dass die vorgelagerte Stromversorgung entsprechend dimensioniert ist, um sowohl diese CPU als auch alle weiteren Module im gleichen X20-Rack zu versorgen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteriewartung:\u003c\/strong\u003e Die interne Batterie versorgt die Echtzeituhr und die Datensicherung der CPU. Überwachen Sie regelmäßig die Batteriestatusanzeige und tauschen Sie die Batterie gemäß dem Wartungsplan von B\u0026amp;R aus, um den Verlust kritischer Konfigurationsdaten oder Zeitstempelgenauigkeit bei Stromausfällen zu vermeiden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermisches Management:\u003c\/strong\u003e Trotz des effizienten Basisverbrauchs von 6 W erzeugt die CPU bei intensiven Rechenaufgaben Wärme. Sorgen Sie für ausreichenden Abstand im X20-Rack und eine effektive Kühlung im Schaltschrank, um die Umgebungstemperatur innerhalb der zulässigen Grenzen zu halten und thermische Drosselung oder vorzeitigen Hardwareausfall zu verhindern.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366105963,"sku":"X20CP1483","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20cp1483-gdl1tgfntec.png?v=1776138161"},{"product_id":"b-r-x20ai4222-x20-analog-input-module-1","title":"B\u0026R X20AI4222 X20 Analoges Eingangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20AI4222 (X20 AI 4222)\u003c\/strong\u003e ist ein leistungsstarkes Analog-Eingangsmodul für das X20-System, das 4 differenzielle Analog-Eingänge für präzise Spannungsmessungen bietet. Entwickelt für anspruchsvolle industrielle Steuerungsumgebungen – einschließlich Automationslinien und Maschinenüberwachung – verfügt dieses Modul über einen Spannungsbereich von ±10 V und eine 13-Bit-Digitalwandlerauflösung (inklusive Vorzeichen). Durch die Integration eines konfigurierbaren Tiefpassfilters 3. Ordnung mit einer Grenzfrequenz von 1 kHz reduziert der X20AI4222 effektiv hochfrequente Störungen, gewährleistet eine zuverlässige Datenqualität für komplexe Regelaufgaben und minimiert das Risiko von Systemausfällen durch Signalrauschen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDie Modularchitektur ist für eine nahtlose Integration in das X20-System optimiert und erfordert für den Betrieb den X20TB12 Klemmenblock sowie das X20BM11 Busmodul. Die Eingänge verwenden ein Successive Approximation Register (SAR)-Verfahren zur schnellen Datenerfassung. Die Diagnosefunktionen sind umfassend und umfassen dedizierte Status-LEDs für kanalbezogene I\/O-Funktionen sowie modulweite Fehlerzustände, die auch vollständig über die Host-Software zugänglich sind. Die elektrische Trennung zwischen den I\/O-Kanälen und dem Backplane-Bus sorgt für eine robuste Barriere gegen elektrische Transienten und Masseschleifen in störanfälligen Anwendungen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20AI4222\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAnalogeingänge\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e4 Differenzielle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eAuflösung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e13 Bit (inkl. Vorzeichen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eEingangsbereich\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eWandlungszeit\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e400 µs (alle Eingänge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eBus-Stromaufnahme\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0,01 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInterne I\/O-Leistung\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e1,1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eEingangswiderstand\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e20 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eSchutzart\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e2,0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIst der X20AI4222 mit Stromsignalen (mA) kompatibel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein, der X20AI4222 ist speziell für ±10 V Spannungssignale ausgelegt. Wenn Sie Strommessungen benötigen, sollten Sie Module wie den X20AI4322 oder X20AI4622 in Betracht ziehen, die Stromschleifeneingänge unterstützen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelche Funktion hat der konfigurierbare Eingangsfilter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer Tiefpassfilter 3. Ordnung mit einer Grenzfrequenz von 1 kHz dient zur Unterdrückung hochfrequenter Störungen oder Signalspitzen. Dies hilft, stabile Analogwerte in Umgebungen mit elektromagnetischen Störungen zu gewährleisten, wie z. B. in der Nähe großer Motoren oder Frequenzumrichter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSind der Klemmenblock und das Busmodul im Lieferumfang enthalten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein, diese sind zwingend erforderliches Zubehör. Sie müssen 1x X20TB12 Klemmenblock und 1x X20BM11 Busmodul separat bestellen, um das Modul in einem X20-Rack zu installieren.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbschirmung und Erdung:\u003c\/strong\u003e Für maximale Signalgenauigkeit verwenden Sie abgeschirmte, verdrillte Leitungen für alle analogen Eingänge. Stellen Sie sicher, dass die Abschirmung an einem einzigen Punkt, idealerweise am Schaltschrankeingang, ordnungsgemäß geerdet ist, um Masseschleifen zu vermeiden, die die 13-Bit-Wandlungsgenauigkeit beeinträchtigen könnten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBetriebsbedingungen:\u003c\/strong\u003e Das Modul unterstützt sowohl horizontale als auch vertikale Montage. Bei horizontaler Montage liegt der Betriebstemperaturbereich bei -25 bis 60 °C. Wenn das Modul in einer Höhe über 2000 m installiert wird, muss die maximale Umgebungstemperatur um 0,5 °C pro 100 m Höhe reduziert werden, um eine thermische Überlastung der internen Komponenten zu vermeiden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eÜberlastschutz:\u003c\/strong\u003e Das Modul ist gegen versehentliche Anschluss an die Versorgungsspannung geschützt. Für eine maximale Lebensdauer stellen Sie jedoch sicher, dass die Eingangssignale die zulässige Grenze von ±30 V nicht überschreiten, um Schäden an der Eingangsstufe zu vermeiden.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366204267,"sku":"X20A14222","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20a14222-chygsv1woiz.png?v=1776138119"},{"product_id":"b-r-x20cat4222-x20-temperature-input-module","title":"B\u0026R X20cAT4222 X20 Temperatur-Eingangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20cAT4222 (X20c AT 4222)\u003c\/strong\u003e ist ein hochpräzises, beschichtetes Temperatureingangsmodul aus dem B\u0026amp;R X20-System, das für einen zuverlässigen Betrieb in rauen Industrieumgebungen entwickelt wurde. Mit 4 Eingängen für Widerstandstemperaturmessungen unterstützt dieses Modul PT100- und PT1000-Sensoren und ist für 3-Draht-Anschlusskonfigurationen optimiert. Die Bezeichnung „c“ weist darauf hin, dass die Elektronik durch eine Schutzbeschichtung (Conformal Coating) geschützt ist, die eine überlegene Beständigkeit gegen Kondensation und korrosive Gase bietet, was es ideal für die chemische Verarbeitung, Außeninfrastruktur oder feuchte Produktionsanlagen macht. Es liefert eine konstante Datenqualität mit einer Auflösung von 0,1 °C und hilft, thermische Messfehler in kritischen Regelkreisanwendungen zu minimieren.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDie Modularchitektur basiert auf einem 16-Bit-Sigma-Delta-Wandler, der eine hohe Genauigkeit und geringe Störanfälligkeit über alle vier Kanäle gewährleistet. Jeder Kanal ist unabhängig für den Sensortyp konfigurierbar, was eine flexible Integration gemischter PT100\/PT1000-Sensorarrays in einem einzigen Modul ermöglicht. Das X20cAT4222 unterstützt einen weiten Bereich an Widerstandsmessungen (0,1 bis 4500 Ohm für PT100\/PT1000) und verfügt über einen konfigurierbaren Eingangfilter (1 ms bis 66,7 ms) zur Reduzierung von Industrie-Störungen. Die Diagnose erfolgt über integrierte Status-LEDs und Software-Rückmeldungen, die sofortige Warnungen bei Unterbrechungen oder Messbereichsüberschreitungen liefern.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20cAT4222\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eEingänge\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e4 (Widerstandstemperatur)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSensorunterstützung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003ePT100 \/ PT1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eAuflösung\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0,1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eAnschlusstyp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e3-Draht\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eWandlung\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e16-Bit Sigma-Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eBeschichtung\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eConformal (kondensations- und korrosionsbeständig)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eBetriebstemperatur\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e-25 bis 60 °C (horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e1,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist der Vorteil der „beschichteten“ Bezeichnung beim X20cAT4222?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Schutzbeschichtung auf der internen Elektronik schützt das Modul vor hoher Luftfeuchtigkeit, Kondensation und korrosiven Industriegasen. Dies verlängert die Lebensdauer des Moduls erheblich in anspruchsvollen Umgebungen, in denen Standardmodule durch Oxidation oder Kurzschlüsse beeinträchtigt werden könnten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses Modul Widerstand direkt messen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, das Modul ist zur direkten Widerstandsmessung geeignet. Es liefert ein Ausgabeformat als INT oder UINT und unterstützt Widerstandsbereiche von 0,1 bis 4500 Ohm (für G=1) bzw. 0,05 bis 2250 Ohm (für G=2).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst der Klemmenblock im Lieferumfang enthalten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein, der X20TB12-Klemmenblock und das X20cBM11-Busmodul sind erforderliches Zubehör und müssen separat bestellt werden.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerdrahtungsstandards:\u003c\/strong\u003e Bei 3-Draht-Anschlüssen sollte der Widerstand der drei Leitungen möglichst ausgeglichen sein, damit das Modul Leitungswiderstandsfehler effektiv kompensieren kann. Verwenden Sie geschirmte verdrillte Leitungen und schließen Sie die Schirme gemäß den etablierten EMV-Richtlinien an, um die Messgenauigkeit zu erhalten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermisches Management:\u003c\/strong\u003e Beachten Sie bei der Installation, dass die horizontale Montage bis 60 °C zulässig ist, während die vertikale Montage auf 50 °C begrenzt ist. Überschreitet die Installationshöhe 2000 m, ist eine Temperaturabminderung von 0,5 °C pro 100 m anzuwenden, um die Sicherheit und Genauigkeit der Analogwandlungsstufe zu gewährleisten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmweltschutz:\u003c\/strong\u003e Obwohl die Schutzbeschichtung einen robusten Schutz gegen atmosphärische Einflüsse bietet, vermeiden Sie den direkten Kontakt des Moduls mit flüssigen Chemikalien oder das Eintauchen. Stellen Sie sicher, dass das Modul in einem entsprechend bewerteten IP-Gehäuse installiert wird, um den Schutzgrad des Gesamtsystems gemäß EN 60529 aufrechtzuerhalten.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366302571,"sku":"X20CAT4222","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20cat4222-wtyjbno0fjv.png?v=1776138156"},{"product_id":"b-r-x20ps9600-x20-series-cpu-system-power-supply","title":"B\u0026R X20PS9600 X20 Serie CPU Systemnetzteil","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20PS9600 (X20 PS 9600)\u003c\/strong\u003e ist ein hochzuverlässiges System-Netzteilmodul, das speziell entwickelt wurde, um die erforderliche Spannung für die X20 CPU und die zugehörige X2X Link-Busarchitektur bereitzustellen. Dieses Modul dient als primäre Energiequelle für B\u0026amp;R Automatisierungscontroller und gewährleistet eine stabile Leistung in anspruchsvollen Industriebereichen wie dem Werkzeugmaschinenbau, der Präzisionsmontage und komplexen Bewegungssteuerungsanwendungen. Durch die Bereitstellung einer geregelten 24 VDC-Ausgangsspannung mit einer robusten Kontaktbelastbarkeit von 10 A schützt das X20PS9600 die CPU und Kommunikationsmodule vor Schwankungen der Hauptversorgung, minimiert effektiv Systeminstabilitäten und schützt vor Datenverlust bei Stromstörungen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas X20PS9600 ist für die tiefe Integration in den X20-Systemschacht konzipiert und verwaltet sowohl die X2X Link-Versorgung als auch die interne I\/O-Stromversorgung. Es verfügt über fortschrittliche Sicherheitsfunktionen, darunter integrierten Verpolungsschutz und eine fest eingebaute, nicht austauschbare Sicherung, die einen sicheren Betriebsablauf gewährleistet. Das Modul akzeptiert einen weiten Eingangsspannungsbereich (24 VDC -15 % \/ +20 %) und bietet somit Widerstandsfähigkeit in Anlagen mit schwankenden Stromnetzen. Sein kompaktes Design umfasst eine zulässige Kontaktbelastung von 10 A, was den Anschluss von leistungsstarken Feldgeräten ermöglicht und gleichzeitig die Integrität der primären Steuerstromversorgung bewahrt.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20PS9600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eFunktion\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eCPU-Systemnetzteil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eNenn-Ausgangsleistung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eNenn-Ausgangsspannung\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eEingangsspannung\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e24 VDC (-15 % \/ +20 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eMaximaler Eingangsstrom\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0,7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eKontaktbelastung\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eSchutzart\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e2,0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIst die integrierte Sicherung im X20PS9600 austauschbar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein, die interne Sicherung ist eine integrierte Sicherheitsfunktion und kann nicht ausgetauscht werden. Wenn die Sicherung auslöst, weist dies in der Regel auf einen erheblichen externen Fehler oder Kurzschluss hin, der behoben werden muss, bevor das Modul wieder sicher verwendet werden kann.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelche externe Absicherung ist für die Eingangsleitung erforderlich?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAuf der Eingangsseite ist eine träge Leitungssicherung mit einer maximalen Nennleistung von 10 A erforderlich, um einen ordnungsgemäßen Schutz des Moduls und der Versorgungsleitungen zu gewährleisten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie geht dieses Modul mit Verpolung um?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas X20PS9600 ist mit einem integrierten Verpolungsschutz ausgestattet, der Schäden an der internen Elektronik verhindert, falls die 24 VDC-Eingangsleitungen bei der Installation versehentlich vertauscht werden.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeitungsschutz:\u003c\/strong\u003e Installieren Sie stets die vorgeschriebene 10 A träge Sicherung in der Eingangsleitung. Dies stellt sicher, dass das Netzteil vor schweren transienten Überspannungen oder nachgeschalteten Kurzschlüssen geschützt ist, die sonst den gesamten Steuerungsschacht gefährden könnten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermische Aspekte:\u003c\/strong\u003e Achten Sie bei der Installation des Moduls darauf, dass die Belüftungswege rund um den X20-Schacht frei bleiben. Obwohl der Stromverbrauch effizient ist (1,42 W für X2X Link und 0,6 W für interne I\/O), muss das Modul eine angemessene Umgebungstemperatur einhalten, um die langfristige Zuverlässigkeit der internen Stromwandlungskomponenten zu gewährleisten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStromverteilung:\u003c\/strong\u003e Nutzen Sie die zulässige Kontaktbelastung von 10 A, um die Stromversorgung effizient auf Peripheriemodule zu verteilen, achten Sie jedoch darauf, dass die Gesamtstromaufnahme die Nennausgangswerte nicht überschreitet. Überprüfen Sie alle Anschlussklemmen regelmäßig, um sicherzustellen, dass sie fest sitzen, da hohe Ströme (10 A) bei erhöhtem Kontaktwiderstand durch lose Schrauben zu Wärmeentwicklung führen können.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366400875,"sku":"X20PS9600","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ps9600-lun0wd25t2e.png?v=1776138220"},{"product_id":"b-r-x20ps8002-x20-series-power-supply-module","title":"B\u0026R X20PS8002 X20 Serie Netzteilmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20PS8002 (X20 PS 8002)\u003c\/strong\u003e ist ein dediziertes Netzteilmodul innerhalb des X20-Systems, das speziell entwickelt wurde, um eine stabile 24 VDC-Versorgung für eigenständige Geräte bereitzustellen. Dieses Modul ist eine entscheidende Komponente, um eine konstante Betriebsspannung in modularen Automatisierungsarchitekturen sicherzustellen und Versorgungsschwankungen von empfindlicher Steuerlogik effektiv zu isolieren. Durch die Aufrechterhaltung einer zuverlässigen Stromversorgung minimiert der X20PS8002 das Risiko von systembedingten Neustarts oder Kommunikationsfehlern aufgrund von Spannungseinbrüchen in anspruchsvollen Industrieumgebungen wie automatisierten Montagelinien, Prozessinstrumentierung und entfernten I\/O-Inseln.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDer X20PS8002 ist auf hohe Effizienz ausgelegt und für die Integration in die X20-Rückwand optimiert. Er liefert eine robuste Leistung bei gleichzeitig niedrigem Eigenverbrauch von 1,34 W. Das Modul ist für eine Nennspannung von 24 VDC mit einer weiten Toleranz von -15 % bis +20 % ausgelegt, sodass es auch bei geringfügigen Versorgungsschwankungen betriebsbereit bleibt. Integrierte Diagnosefunktionen, einschließlich spezieller Statusanzeigen für Betriebszustand und Modulstatus, bieten dem Wartungspersonal eine sofortige visuelle Bestätigung der Stromversorgungsqualität. Das kompakte Design sorgt dafür, dass es nur minimalen Platz im Schaltschrank einnimmt und dennoch den erforderlichen Strom für periphere eigenständige Komponenten liefert.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20PS8002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eFunktion\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e24 VDC Netzteil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eEingangsspannung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e24 VDC (-15 % \/ +20 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eMaximaler Eingangsstrom\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0,7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eLeistungsaufnahme\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e1,34 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e1,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist die Hauptfunktion des X20PS8002?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul ist speziell dafür ausgelegt, eine dedizierte 24 VDC-Stromquelle für eigenständige Geräte innerhalb des X20-Ökosystems bereitzustellen und sicherzustellen, dass diese eine stabile, vom Hauptbus unabhängige Stromversorgung erhalten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenötigt dieses Modul eine spezielle Belüftung?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eObwohl der X20PS8002 einen niedrigen Stromverbrauch hat, sollten die üblichen Belüftungspraktiken im Schaltschrank eingehalten werden. Stellen Sie sicher, dass das Modul in einer Umgebung installiert wird, in der die Umgebungstemperaturen innerhalb der angegebenen Grenzen bleiben, um die Lebensdauer zu maximieren.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie überwache ich den Status der Stromversorgung?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul verfügt über frontseitige LED-Anzeigen für den Betriebszustand und den Modulstatus. Wenn die Statusanzeige einen Fehler signalisiert, erkennt das Modul wahrscheinlich eine Eingangsspannung außerhalb des spezifizierten Bereichs von -15 % bis +20 % oder einen internen Fehler.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEingangsschutz:\u003c\/strong\u003e Obwohl der X20PS8002 robust ausgelegt ist, stellen Sie sicher, dass die vorgelagerte 24 VDC-Quelle durch eine schnell ansprechende Sicherung oder einen Leistungsschalter geschützt ist, der die Eingangsverdrahtung und das Modul im Falle eines Kurzschlusses absichert.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerdrahtung:\u003c\/strong\u003e Verwenden Sie beim Anschluss des 24 VDC-Eingangs Kupferleitungen mit geeignetem Querschnitt, um Spannungsabfälle an der Verbindung zu minimieren. Stellen Sie sicher, dass alle Klemmen gemäß den im X20-Systemhandbuch angegebenen Drehmomentwerten festgezogen sind, um intermittierende Verbindungen durch thermische Ausdehnung oder Schaltschrankvibrationen zu vermeiden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotentialausgleich:\u003c\/strong\u003e Für optimale Leistung und Störsicherheit stellen Sie sicher, dass die Stromversorgung ordnungsgemäß auf das gemeinsame Massepotenzial des Systems bezogen ist. Eine korrekte Erdung minimiert das Risiko von Masseschleifen, insbesondere in Konfigurationen, bei denen dieses Modul Sensoren oder Aktoren über einen großen Maschinenrahmen versorgt.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366531947,"sku":"X20PS8002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ps8002-4tzlzdz3drc.png?v=1776138217"},{"product_id":"b-r-x20dif371-x20-series-digital-input-module","title":"B\u0026R X20DIF371 X20 Serie Digitales Eingangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20DIF371 (X20 DIF 371)\u003c\/strong\u003e ist ein Digital-Eingangsmodul mit hoher Dichte, das speziell für die B\u0026amp;R X20 Automatisierungsplattform entwickelt wurde. Dieses Modul bietet 16 digitale Eingänge mit einer Nennspannung von 24 VDC und verwendet eine Source-Schaltungsarchitektur, die speziell für 1-Draht-Verbindungen ausgelegt ist. Ideal für komplexe Maschinensteuerungen in Branchen wie der Automobilmontage, Verpackung und Hochgeschwindigkeitsverarbeitung ermöglicht der X20DIF371 eine effiziente Signalaufnahme in großem Umfang. Durch den Einsatz eines softwarekonfigurierbaren Eingangsfilters eliminiert das Modul effektiv Signalprellen und elektrische Störungen, gewährleistet eine hochpräzise Datenübertragung an die Steuerung und reduziert die Wahrscheinlichkeit von unregelmäßigem Maschinenverhalten oder Fehlalarmen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eFür die nahtlose Integration in das B\u0026amp;R X20 System benötigt das Modul den X20TB1F Klemmenblock und das X20BM11 Busmodul, um die standardmäßige 12,5 mm Rastermontage zu ermöglichen. Die Hardware unterstützt sowohl horizontale als auch vertikale Montageausrichtungen und bietet somit Flexibilität in beengten Schaltschrankumgebungen. Jeder Kanal verfügt über eigene Statusanzeigen, ergänzt durch modulweite Lauf-\/Fehlerdiagnosen, die sowohl über die physische LED-Anzeige als auch über die Host-Software zugänglich sind. Die Eingangsschaltung ist für Sink-Eingangsverdrahtung optimiert, und der systemweit programmierbare Filter erlaubt es Ingenieuren, die Eingangsreaktionszeit an die spezifischen Anforderungen der angeschlossenen Feldsensoren anzupassen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20DIF371\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eDigitale Eingänge\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eEingangsschaltung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eSource- \/ Sink-Eingangsverdrahtung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eAnschlusstyp\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e1-Draht\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eBus-Stromaufnahme\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0,18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eInterne I\/O-Leistung\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e1,47 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eBetriebstemperatur\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-25 bis 60 °C (horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eSchutzart\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e2,0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIst der X20DIF371 mit Standard-Sink-\/Source-Sensortypen kompatibel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDieses Modul ist speziell für Sink-Eingangsverdrahtung ausgelegt. Stellen Sie sicher, dass Ihre Feldsensoren so konfiguriert sind, dass sie das korrekte Schaltsignal liefern, das mit der Source-Schaltungsarchitektur dieses Moduls kompatibel ist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie stelle ich den Eingangsfilter für das Modul ein?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer Eingangsfilter wird über die B\u0026amp;R Automatisierungssoftware konfiguriert, die es Ihnen ermöglicht, die Filterdauer für das gesamte Modul einzustellen. Dies ist besonders nützlich zur Unterdrückung von Störungen in Umgebungen mit starker elektromagnetischer Beeinflussung.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSind die notwendigen Montagezubehörteile im Lieferumfang des Moduls enthalten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein, für die Installation des X20DIF371 müssen der X20TB1F Klemmenblock und das X20BM11 Busmodul separat erworben werden.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUmweltbedingte Leistungsanpassung:\u003c\/strong\u003e Obwohl das Modul für den Betrieb bis 60 °C in horizontaler Ausrichtung ausgelegt ist, stellen Sie sicher, dass bei einer Installation über 2000 m Höhe die Umgebungstemperatur entsprechend angepasst wird. Für je 100 m über diesem Schwellenwert reduzieren Sie die maximal zulässige Umgebungstemperatur um 0,5 °C, um die Lebensdauer der Komponenten zu erhalten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerdrahtungsintegrität:\u003c\/strong\u003e Aufgrund des 1-Draht-Anschlussdesigns sollten saubere Signalwege eingehalten werden, um Übersprechen zu minimieren. Verwenden Sie geschirmte Kabel, wenn Signalwege mehrere Meter überschreiten, und stellen Sie sicher, dass die Abschirmung gemäß den EMC-Richtlinien Ihrer Anlage terminiert ist, um die volle Leistungsfähigkeit der konfigurierbaren Eingangsfilter zu nutzen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchaltschrankplatzierung:\u003c\/strong\u003e Bei vertikaler Montage beachten Sie die untere Temperaturgrenze von 50 °C. Sorgen Sie dafür, dass das Kühlsystem des Schranks die Luft ungehindert über die Modulrippen leitet, um lokale Hotspots zu vermeiden, die die Eingangszeitpräzision beeinträchtigen könnten.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366695787,"sku":"X20DIF371","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20dif371-5olzrykxnn0.png?v=1776138184"},{"product_id":"b-r-x20do6322-x20-series-digital-output-module","title":"B\u0026R X20DO6322 X20 Serie Digitales Ausgangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20DO6322 (X20 DO 6322)\u003c\/strong\u003e ist ein kompaktes Digitalausgangsmodul, das für das B\u0026amp;R X20 Automatisierungssystem entwickelt wurde und schnellen Schaltbetrieb für industrielle Steuerungsanwendungen bietet. Mit 6 digitalen Ausgängen bei 24 VDC unterstützt dieses Modul sowohl 1-Draht- als auch 2-Draht-Anschlussarchitekturen und bietet Flexibilität für verschiedene Aktuator-Konfigurationen. Optimiert für den Einsatz in dezentralen Automatisierungsumgebungen – wie Materialhandling, Montage-Robotik und Prozessüberwachung – gewährleistet der X20DO6322 präzise Signalausgabe mit einem Nennstrom von 0,5 A pro Kanal. Sein modulares Design ermöglicht eine schnelle Inbetriebnahme und minimalen Wartungsaufwand, wodurch Ausfallzeiten in kritischen Fertigungsprozessen erheblich reduziert werden.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDie Modularchitektur ist für die Integration in die X20-Rückwand ausgelegt und behält dabei eine schlanke Bauform bei, die die Schrankdichte maximiert. Der X20DO6322 verfügt über umfassende Statusdiagnosen mit dedizierten LEDs für I\/O-Funktion, Betriebszustand und den Gesamtzustand des Moduls. Dieses Echtzeit-Visuelles Feedback in Kombination mit softwarezugänglichen Diagnosen ermöglicht es Wartungstechnikern, Fehler während des Betriebs schnell zu lokalisieren. Die elektrische Trennung zwischen Bus und I\/O-Kanälen bietet eine robuste Barriere gegen elektrische Störungen und gewährleistet Datenintegrität selbst in Umgebungen mit starker elektromagnetischer Beeinflussung. Das Gerät ist nach IP20 klassifiziert und eignet sich für Steuerungsschränke in kontrollierten Umgebungen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20DO6322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eDigitale Ausgänge\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eNennspannung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eAusgangsstrom\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0,5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eAnschlusstyp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e1-Draht oder 2-Draht\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eBus-Stromaufnahme\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0,18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInterne I\/O-Leistung\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e0,71 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eSchutzart\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e2,0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas sind die Hauptvorteile der 1-Draht- gegenüber der 2-Draht-Verbindung?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie 1-Draht-Konfiguration wird typischerweise verwendet, um die Verdrahtungsdichte im Feld zu minimieren, während die 2-Draht-Verbindung bevorzugt wird, wenn ein dedizierter Rückleiter für den Aktuator erforderlich ist, um Potentialunterschiede zu reduzieren und die Signalzuverlässigkeit in störanfälligen Umgebungen zu verbessern.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie wird der Modulstatus an die Steuerung übermittelt?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul kommuniziert seinen Betriebszustand und den kanalbezogenen I\/O-Status direkt über die X20-Bus-Rückwand. Dadurch kann die zentrale SPS Kurzschlüsse, offene Lasten oder Kommunikationsfehler überwachen, ohne zusätzliche Verdrahtung zu benötigen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst dieses Modul für Anwendungen mit hoher Vibration geeignet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, die X20-Serie ist für hohe mechanische Robustheit ausgelegt. Stellen Sie jedoch sicher, dass das Modul korrekt auf der Busbasis sitzt und alle Feldverdrahtungen gemäß den industriellen Standards gesichert sind, um ein Lockern der Steckverbinder im Laufe der Zeit zu verhindern.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerdrahtungshinweise:\u003c\/strong\u003e Bei Verwendung von 2-Draht-Verbindungen ist darauf zu achten, dass das gemeinsame Potential korrekt über den Klemmenblock geführt wird, um Stromschleifen zu vermeiden. Verwenden Sie Aderendhülsen für alle Litzenanschlüsse, um eine zuverlässige mechanische Verbindung in den Feder- oder Schraubklemmen sicherzustellen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSicherheit und Schutz:\u003c\/strong\u003e Der X20DO6322 ist mit internem Schutz ausgestattet, jedoch wird bei induktiven Lasten wie Schützen oder Magnetventilen dringend empfohlen, externe Freilaufdioden zu verwenden. Diese Maßnahme verhindert induktive Spannungsspitzen, die die Ausgangstransistoren beschädigen könnten, und verlängert die Lebensdauer des Moduls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Überprüfen Sie vor der Inbetriebnahme, ob die Firmware des Moduls mit Ihrer aktuellen B\u0026amp;R Automatisierungssoftware kompatibel ist. Nutzen Sie beim Start die Status-LEDs, um zu bestätigen, dass das Modul erfolgreich mit dem Buscontroller kommuniziert, bevor Sie die aktive Signalausgabe an Feldgeräte freigeben.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366728555,"sku":"X20DO6322","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20do6322-bzyrivu1dso.png?v=1776138192"},{"product_id":"b-r-x20ai4622-x20-series-analog-input-module","title":"B\u0026R X20AI4622 X20 Serie Analoges Eingangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20AI4622 (X20 AI 4622)\u003c\/strong\u003e ist ein leistungsstarkes Analog-Eingangsmodul, das für präzise Prozessüberwachung im B\u0026amp;R X20 Automatisierungssystem entwickelt wurde. Es ist für anspruchsvolle Industrieumgebungen konzipiert – darunter Kraftwerke, chemische Verarbeitungsanlagen und automatisierte Fertigungslinien – und bietet 4 differenzielle Eingänge, die sowohl Strom- als auch Spannungssignale verarbeiten können. Durch die zuverlässige, hochauflösende Signalaufnahme reduziert das X20AI4622 die Latenzzeit vom Sensor zum Steuergerät erheblich und minimiert das Risiko ungeplanter Ausfallzeiten durch Signalungenauigkeiten. Sein kompaktes Design und die modulare Architektur gewährleisten eine nahtlose Integration in bestehende Schaltschranklösungen und liefern die robuste Datenqualität, die für komplexe Regelkreisanwendungen erforderlich ist.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas Modul verfügt über einen hochpräzisen 13-Bit-Digitalwandler (inklusive Vorzeichen) basierend auf dem Successive Approximation Register (SAR)-Verfahren. Es ist vielseitig einsetzbar und ermöglicht dem Anwender, durch Auswahl der entsprechenden Anschlussklemmen zwischen Spannungsmodus (±10 V) und Strommodus (0 bis 20 mA oder 4 bis 20 mA) zu wechseln. Das Modul ist mit einem Tiefpass-Eingangsfilter 3. Ordnung mit einer Grenzfrequenz von 1 kHz ausgestattet, um hochfrequente Störungen von Industrieanlagen zu eliminieren. Eine elektrische Trennung zwischen den I\/O-Kanälen und dem Backplane-Bus schützt die CPU und nachgelagerte Verarbeitungskomponenten vor möglichen Transienten. Die Statusüberwachung ist umfassend: Integrierte LEDs zeigen kanalbezogene I\/O-Funktionen an, und modulweite Fehlerdiagnosen sind über die Software zugänglich.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20AI4622\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAnalogeingänge\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e4 Differenzielle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eAuflösung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e13 Bit (inklusive Vorzeichen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eWandlungszeit\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e400 Mikrosekunden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eEingangswiderstand (Spannung)\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e20 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eEingangsschutz\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eMax. ±30 V (Spannung) \/ Max. ±50 mA (Strom)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eBus-Stromaufnahme\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e0,01 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eInterne I\/O-Stromaufnahme\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1,1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eBetriebstemperatur\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e-25 bis 60 °C (horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eSchutzart\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e1,0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIst das X20AI4622 mit allen X20-Backplanes kompatibel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, es ist für die Standard-X20-Systemarchitektur ausgelegt, jedoch müssen das X20BM11 Busmodul und der X20TB12 Anschlussblock separat bestellt werden, da diese nicht im Lieferumfang des Moduls enthalten sind.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie wechselt man zwischen Spannungs- und Stromeingangsmodus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Auswahl erfolgt hardwareseitig. Das Eingangssignal muss an die jeweils für Spannung oder Strom vorgesehenen Anschlussklemmen gemäß dem B\u0026amp;R Benutzerhandbuch angeschlossen werden.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist zu tun, wenn das Modul eine Überlast meldet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul verfügt über konfigurierbare Diagnosen. Bei Erkennung einer Überlast kann der digitale Ausgangswert über die Softwarekonfiguration eingestellt werden; prüfen Sie Ihre Softwareprojekteinstellungen, um sicherzustellen, dass das Fehlerverhalten Ihren Sicherheitsanforderungen entspricht.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerdrahtung und Abschirmung:\u003c\/strong\u003e Für maximale Signalqualität sollten stets geschirmte verdrillte Leitungen für analoge Signale verwendet werden. Die Kabelabschirmung ist an einem Punkt – vorzugsweise am Schaltschrank-Eintritt – zu erden, um Masseschleifen zu vermeiden, die die 13-Bit-Wandlungspräzision beeinträchtigen könnten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermisches Management:\u003c\/strong\u003e Beim Einbau des Moduls in einen Schaltschrank ist ein Mindestabstand von 12,5 mm für ausreichende Luftzirkulation einzuhalten. Überschreitet die Installationshöhe 2000 m über dem Meeresspiegel, ist die zulässige Umgebungstemperatur um 0,5 °C pro 100 m Höhe zu reduzieren, um thermische Belastungen der internen Bauteile zu vermeiden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnschlusssicherheit:\u003c\/strong\u003e Das X20AI4622 ist für den Einsatz in explosionsgefährdeten Bereichen (Klasse I, Division 2) zugelassen. Vor Wartungsarbeiten ist sicherzustellen, dass keine brennbaren Gaskonzentrationen vorhanden sind und das Modul vor dem Ausbau aus dem X20BM11 Busmodul spannungsfrei geschaltet ist, um Lichtbögen zu verhindern.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366859627,"sku":"X20AI4622","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/X20AI4622-nio4mh0jt55.png?v=1776138123"},{"product_id":"b-r-x20at2311-temperature-measurement-module","title":"B\u0026R X20AT2311 Temperaturmessmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20AT2311 (X20AT2311)\u003c\/strong\u003e ist ein Präzisions-Temperaturmessmodul im B\u0026amp;R X20-System, das für eine genaue thermische Datenerfassung in industriellen Steuerungsumgebungen entwickelt wurde. Dieses Modul ist unerlässlich für Anwendungen, die eine stabile Prozessüberwachung erfordern, wie z. B. Extrusionstemperaturregelung, Ofenmanagement und Überwachung von Kühlsystemen. Durch die Integration einer hochauflösenden Analog-Digital-Wandlung stellt das X20AT2311 sicher, dass Temperaturschwankungen mit minimaler Verzögerung erkannt und verarbeitet werden, sodass die SPS präzise Regelkreise ausführen und optimale thermische Bedingungen aufrechterhalten kann, um Qualitätsabweichungen und prozessbedingte Ausfallzeiten zu vermeiden.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas Modul ist so konzipiert, dass es vielfältige Anforderungen an die Temperaturerfassung mit hoher Zuverlässigkeit erfüllt:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor-Kompatibilität:\u003c\/strong\u003e Das X20AT2311 ist für die direkte Anbindung an standardisierte industrielle Temperatursensoren optimiert und liefert stabile Messwerte für verschiedene Thermoelement- oder RTD-Typen, abhängig von der jeweiligen Modellkonfiguration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalaufbereitung:\u003c\/strong\u003e Es verfügt über integrierte Signalaufbereitung und Kaltstellenkompensation (bei Thermoelement-Varianten), wodurch Temperaturschwankungen am Anschluss nicht die Genauigkeit der Prozessmessungen beeinträchtigen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHochgeschwindigkeitsverarbeitung:\u003c\/strong\u003e Das Modul liefert digitalisierte Temperaturwerte mit hohen Zyklusraten an den X20-Rückplane, was eine schnelle Reaktion in kritischen Regelkreisen ermöglicht.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnosefunktionen:\u003c\/strong\u003e Integrierte Diagnosen erkennen Drahtbrüche oder Kurzschlüsse am Sensor, sodass die Steuerung fehlerhafte Sensoren sofort melden und in einen sicheren Zustand wechseln kann.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20AT2311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProdukttyp\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eTemperaturmessmodul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMontage\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eX20 DIN-Schiene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eBetriebstemperatur\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eIndustriestandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0,2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eVersandgewicht\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWie stelle ich die Genauigkeit der Temperaturmessung sicher?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Genauigkeit hängt stark von einer ordnungsgemäßen Abschirmung und Erdung ab. Stellen Sie sicher, dass die Sensorleitungen abgeschirmt sind und die Abschirmung am Schaltschrank-Eintrittspunkt geerdet ist, um elektromagnetische Störungen (EMI) zu vermeiden, die Rauschen in den niederpegeligen Signalwegen verursachen könnten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses Modul einen abgetrennten Sensor erkennen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, das X20AT2311 verfügt über integrierte Diagnosefunktionen, die offene Schaltkreise (Drahtbruch) oder Kurzschlüsse erkennen können. Diese Statusbits werden in der SPS-Software für eine automatisierte Alarmbehandlung abgebildet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenötige ich einen speziellen Anschlussklemmenblock für dieses Modul?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, die X20-Serie erfordert einen spezifischen Anschlussklemmenblock. Stellen Sie sicher, dass Sie die passende X20-Klemmenblock-Variante wählen, die mit dem Drahtquerschnitt und dem Verbindungstyp Ihres Sensors kompatibel ist.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeitungslängen:\u003c\/strong\u003e Halten Sie die Sensorverkabelung so kurz wie möglich. Bei Thermoelement-Sensoren sollten die Verlängerungsleitungen aus dem gleichen Material wie das Thermoelement bestehen, um Sekundärstellenfehler zu vermeiden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStörungsminimierung:\u003c\/strong\u003e Führen Sie Temperaturmesskabel in separaten Leitungen, getrennt von Hochspannungs-Wechselstromleitungen, Frequenzumrichter-Motorkabeln und Stromversorgungsleitungen. Falls eine Kreuzung unvermeidbar ist, sollte diese im 90-Grad-Winkel erfolgen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermische Kalibrierung:\u003c\/strong\u003e Führen Sie bei der Erstinbetriebnahme eine Vergleichsmessung mit einem kalibrierten Handthermometer am Sensorstandort durch. Überprüfen Sie, dass die Werte in der B\u0026amp;R-Automatisierungssoftware mit der tatsächlichen Temperatur übereinstimmen, um eine korrekte Skalierung und Offset-Einstellung sicherzustellen.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086367351147,"sku":"X20AT2311","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20at2311-epuobqbxbq3.png?v=1776138131"},{"product_id":"b-r-x20bc0043-10-i-o-controller","title":"B\u0026R X20BC0043-10 I\/O Steuerung","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDer \u003cstrong\u003eX20BC0043-10 (X20BC0043-10)\u003c\/strong\u003e ist ein robuster I\/O-Controller, der für das B\u0026amp;R X20-Automatisierungssystem entwickelt wurde und als primäre Kommunikationsbrücke zwischen einem Feldbusnetzwerk und den lokalen X20 I\/O-Slices fungiert. Dieser Controller ist entscheidend in verteilten Automatisierungsarchitekturen und ermöglicht die zuverlässige Übertragung von Prozessdaten über Entfernungen von bis zu 1000 Metern. Durch die Bereitstellung eines schnellen, deterministischen Datenaustauschs stellt der X20BC0043-10 sicher, dass komplexe Maschinensteuerungslogiken – von Hochgeschwindigkeitsverpackungsanwendungen bis hin zur Mehrachsen-Prozesssteuerung – synchron und reaktionsfähig bleiben, wodurch Datenlatenzen und damit verbundene Systemausfälle effektiv vermieden werden.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDer Controller ist für eine leistungsstarke Integration und einfache Inbetriebnahme ausgelegt. Er verfügt über einen 5-poligen Stecker für die Feldbusanbindung und ist für einen energiesparenden Betrieb optimiert.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatenübertragung:\u003c\/strong\u003e Unterstützt eine zuverlässige Kommunikation über große Entfernungen und ist somit ideal für dezentrale Bedienpanels, die über große Fertigungshallen verteilt sind.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKonnektivität:\u003c\/strong\u003e Die integrierte 5-polige Stecker-Schnittstelle vereinfacht die Installation der physikalischen Schicht und gewährleistet eine sichere und vibrationsfeste Verbindung.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEffizienz:\u003c\/strong\u003e Mit einem Stromverbrauch von nur 1,5 W arbeitet der Controller mit niedriger Betriebstemperatur, was den thermischen Fußabdruck im Schaltschrank reduziert und zur Gesamteffizienz des Systems beiträgt.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eX20 Skalierbarkeit:\u003c\/strong\u003e Fungiert als Kopf einer X20-Station und ermöglicht das nahtlose Hinzufügen oder Ersetzen von I\/O-Slices, ohne den übergeordneten Netzwerkkommunikationsprotokoll zu unterbrechen.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20BC0043-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProdukttyp\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eI\/O-Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMaximale Übertragungsdistanz\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eLeistungsaufnahme\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e1,5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSchnittstelle\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e5-poliger Stecker (männlich)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0,3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eVersandgewicht\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eLieferzeit\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1 bis 10 Werktage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWelche Vorteile bietet die 1000-Meter-Kommunikationsreichweite?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie 1000-Meter-Reichweite ermöglicht die Zentralisierung der Steuerungslogik in einem einzigen Serverraum oder Schaltschrank, während die I\/O-Knoten direkt auf Maschinenniveau verteilt werden. Dies reduziert den Verkabelungsaufwand im Feld erheblich.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst dieser Controller mit allen X20 I\/O-Slices kompatibel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, der X20BC0043-10 ist so konzipiert, dass er mit der gesamten X20-Serie von I\/O-Modulen kommuniziert, vorausgesetzt, die Projektkonfiguration in der B\u0026amp;R-Software (Automation Studio) enthält die korrekte Modulzuordnung und Firmware-Unterstützung.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie überprüfe ich den Verbindungsstatus des Controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul verfügt über integrierte Status-LEDs, die den Kommunikationsstatus, die Modulgesundheit und die Busaktivität anzeigen. Für detaillierte Fehlercodes konsultieren Sie die B\u0026amp;R-Diagnosesoftware, falls die Statusanzeige einen nicht betriebsbereiten Zustand anzeigt.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteckerintegrität:\u003c\/strong\u003e Beim Anschließen des 5-poligen Steckers ist darauf zu achten, dass das Kabel ordnungsgemäß entlastet wird. Hochfrequente Vibrationen in industriellen Umgebungen können Stecker im Laufe der Zeit lockern und zu intermittierenden Busfehlern führen. Stellen Sie sicher, dass der Verriegelungsmechanismus vollständig eingerastet ist.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbschirmung und Erdung:\u003c\/strong\u003e Bei einer Übertragungsdistanz von 1000 Metern ist elektromagnetische Störung (EMI) ein wesentlicher Faktor. Verwenden Sie stets hochwertige, geschirmte verdrillte Kommunikationskabel und schließen Sie die Abschirmung an beiden Enden an die Funktionserde (FE) des Schaltschranks an, um die Signalqualität sicherzustellen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermisches Management:\u003c\/strong\u003e Obwohl der Controller nur 1,5 W verbraucht, sollte die Station vertikal montiert werden und ausreichend Freiraum für natürliche Konvektion bieten, insbesondere in Schaltschränken mit wärmeintensiven Komponenten wie Frequenzumrichtern oder leistungsstarken Netzteilen.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086367613291,"sku":"X20BC0043-10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20bc0043-10-3pa0kdrsovd.png?v=1776138138"},{"product_id":"b-r-x20bm01-power-supply-bus-module","title":"B\u0026R X20BM01 Netzteil-Busmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20BM01 (X20BM01)\u003c\/strong\u003e ist ein spezialisiertes Basismodul für das B\u0026amp;R X20 I\/O-System und dient als Stromverteilungspunkt für die 24 VDC I\/O-Versorgung. Dieses Modul ist unerlässlich, um die Stromverteilung innerhalb eines Schaltschrankes zu segmentieren und ist speziell darauf ausgelegt, eine 24 VDC-Versorgung bereitzustellen, während die interne I\/O-Versorgung nach links unterbrochen wird. Durch den Einsatz des X20BM01 können Ingenieure Stromsegmente effektiv isolieren, nachgeschaltete Module vor möglichen elektrischen Fehlern schützen und hohe Stromanforderungen in komplexen Automatisierungsanlagen steuern. Sein robustes Design gewährleistet eine zuverlässige mechanische und elektrische Verbindung für die gesamte X20-Slice-Architektur.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas X20BM01 fungiert als strukturelles und elektrisches Rückgrat des X20-Systems, ermöglicht modulare Erweiterungen und gewährleistet gleichzeitig eine strikte Stromkontrolle. Wichtige Merkmale sind:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStromsegmentierung:\u003c\/strong\u003e Das Modul stellt einen kritischen Verbindungspunkt dar, an dem die interne I\/O-Versorgungsschiene nach links physisch unterbrochen wird, sodass das System in unabhängige Stromzonen aufgeteilt werden kann.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchlüsselung:\u003c\/strong\u003e Das Modul ist für 24 VDC ausgelegt, wodurch sichergestellt wird, dass nur kompatible Versorgungsmodule eingesetzt werden können, um Verdrahtungsfehler zu vermeiden, die zu Hardwareschäden führen könnten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNiedriger Verbrauch:\u003c\/strong\u003e Mit einem minimalen internen Stromverbrauch von nur 0,13 W arbeitet das Modul sehr energieeffizient und trägt zu einer geringen Wärmeentwicklung im Schaltschrank bei.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrierte Konnektivität:\u003c\/strong\u003e Das Modul ist so konzipiert, dass es direkt auf die DIN-Schiene aufgeklickt wird und eine vibrationsfeste Verbindung bietet, die die Hot-Swap-Fähigkeit der X20 I\/O-Module unterstützt und die Wartung vor Ort erleichtert.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20BM01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eModultyp\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eStromversorgungs-Busmodul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eEingangsspannung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e24 VDC (gekeyt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eVersorgungsunterbrechung\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eNach links unterbrochen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eBus-Stromverbrauch\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0,13 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0,1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eVersandgewicht\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWarum muss ich die I\/O-Versorgung nach links unterbrechen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Unterbrechung der Versorgung ist notwendig, wenn isolierte Stromsegmente geschaffen werden sollen (z. B. Trennung sicherheitsrelevanter I\/O von Standard-Digital-I\/O oder Isolierung von Hochstrom-Ausgangsstufen), um zu verhindern, dass Fehler sich über die gesamte Backplane ausbreiten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst dieses Modul mit allen X20-Slice-Modulen kompatibel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas X20BM01 ist ein Basismodul für das X20-System. Obwohl es physisch mit der Backplane kompatibel ist, sollte stets sichergestellt werden, dass die Gesamtstromaufnahme der Module im versorgten Segment die Kapazität der an dieses Busmodul angeschlossenen Stromversorgung nicht überschreitet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie wird die 24 VDC-Versorgung an das X20BM01 angeschlossen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Stromversorgung erfolgt typischerweise über den im X20-System integrierten Klemmenblock oder über eine dedizierte Versorgungsklemme, abhängig vom spezifischen Schaltschranklayout Ihres X20-Systems.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegment-Design:\u003c\/strong\u003e Berechnen Sie bei der Planung Ihrer Steuerungsarchitektur den maximalen Stromverbrauch aller Module in einem einzelnen Stromsegment. Verwenden Sie das X20BM01, um das Segment zu unterbrechen, wenn der Stromverbrauch die maximale Kapazität der Versorgungsschiene erreicht, um Spannungsabfälle und thermische Probleme zu vermeiden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Schienenmontage:\u003c\/strong\u003e Stellen Sie sicher, dass die DIN-Schiene sicher montiert und geerdet ist. Das X20BM01 ist auf die strukturelle Integrität der Schiene für mechanische Stabilität angewiesen. Klicken Sie das Modul während der Installation ein, bis ein deutliches Klicken zu hören ist, um sicherzustellen, dass die Backplane-Steckverbinder vollständig eingerastet sind.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWartung:\u003c\/strong\u003e Obwohl das Modul selbst passiv ist, sollten die Stromversorgungsklemmen regelmäßig auf Oxidationsspuren oder lose Verbindungen überprüft werden, insbesondere in Umgebungen mit hoher Maschinenvibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086367744363,"sku":"X20BM01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20bm01-axdrjd0mw4f.png?v=1776138142"},{"product_id":"b-r-x20dc2396-digital-counter-module","title":"B\u0026R X20DC2396 Digitalzähler-Modul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DC2396 (X20DC2396)\u003c\/strong\u003e ist ein spezialisiertes digitales Zählermodul für das B\u0026amp;R X20-System, das für die Schnittstelle mit hochpräzisen Bewegungsrückmeldesystemen entwickelt wurde. Speziell konfiguriert zur Unterstützung von zwei ABR (A, B und Referenz) Inkrementalgebern mit 24 V, ist dieses Modul unerlässlich für Anwendungen, die eine genaue Positions-, Geschwindigkeits- und Distanzüberwachung erfordern. Durch die Bereitstellung von Echtzeit-Feedback an die Steuerung ermöglicht das X20DC2396 eine präzise Synchronisation von Achsen in komplexen automatisierten Maschinen, wie Hochgeschwindigkeits-Etikettiermaschinen, Dreh-Indexiertischen und Materialhandhabungseinheiten. Die Integration in die X20-Rückwand gewährleistet eine schnelle Datenübertragung und trägt zur Aufrechterhaltung der Betriebssicherheit bei, indem die Latenz im Regelkreis minimiert wird.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas X20DC2396 ist für den robusten Industrieeinsatz ausgelegt und legt den Fokus auf Signalqualität und zuverlässige Zustandsüberwachung. Das Modul verwendet Hochgeschwindigkeits-Schaltungen zur Verarbeitung der ABR-Eingangssignale, wodurch die Steuerung sowohl Position als auch Drehrichtung präzise bestimmen kann.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEncoder-Unterstützung:\u003c\/strong\u003e Dedizierte Eingänge für zwei 24 V Inkrementalgeber, einschließlich Unterstützung für die Überwachung des Referenzimpulses (Z-Kanal), um eine genaue Heimpositionierung zu ermöglichen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnoseüberwachung:\u003c\/strong\u003e Das Modul verfügt über umfassende Statusanzeigen, die Echtzeit-Feedback zur I\/O-Funktion pro Kanal, zum internen Betriebszustand und zum Gesamtstatus des Moduls liefern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eX20-Integration:\u003c\/strong\u003e Als Slice-Modul unterstützt es die nahtlose Integration in bestehende X20-Fern-I\/O-Stationen und erleichtert die Erweiterung der Bewegungssteuerungsfunktionen ohne größere Hardwareänderungen.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20DC2396\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eModultyp\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eDigitales Zählermodul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eUnterstützte Encoder\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e2 x ABR Inkrementalgeber (24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eStatusanzeigen\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eI\/O-Funktion, Betriebszustand, Modulstatus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0,3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eVersandgewicht\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e1,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eLieferzeit\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e8 bis 10 Wochen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas sind die Hauptvorteile der ABR-Encoder-Unterstützung in diesem Modul?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Einbeziehung des Referenzimpulses (R) (Z-Kanal) ermöglicht es der Steuerung, für jeden Zyklus eine präzise absolute Heimposition festzulegen, was für Maschinen, die häufig auf eine Nullposition zurückindexieren müssen, von entscheidender Bedeutung ist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSind die Encoder-Eingänge mit 24 V Signal-Logik kompatibel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, das X20DC2396 ist speziell für 24 VDC Inkrementalgeber-Signale ausgelegt und gewährleistet die direkte Kompatibilität mit den meisten industriellen Näherungs- und Drehgebern, ohne dass externe Pegelwandler erforderlich sind.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie kann ich einen Signalverlust eines Encoders beheben?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie integrierten Statusanzeigen des Moduls bieten sofortiges visuelles Feedback. Wenn die Anzeige „I\/O-Funktion“ für einen bestimmten Kanal inaktiv ist, überprüfen Sie zunächst die physikalische Verkabelung und die Stromversorgung des Encoders, bevor Sie den Eingangsstatus in den B\u0026amp;R-Software-Diagnoseregistern prüfen.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalabschirmung:\u003c\/strong\u003e Um Impulszählfehler durch elektromagnetische Störungen (EMI) zu vermeiden, verwenden Sie geschirmte verdrillte Aderpaare für alle A-, B- und R-Signalleitungen. Verbinden Sie die Kabelabschirmung am Eintrittspunkt mit der gemeinsamen Erdungsebene des Schaltschrankes mittels EMV-zertifizierter Kabelverschraubungen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerkabelungsweg:\u003c\/strong\u003e Verlegen Sie Encoder-Signalkabel niemals parallel zu Hochstrom-Motorkabeln oder Ausgangsleitungen von Frequenzumrichtern. Halten Sie einen Mindestabstand von 200 mm ein oder verwenden Sie geerdete Metallrohre, um Steuerleitungen von Stromleitungen zu trennen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanische Montage:\u003c\/strong\u003e Stellen Sie sicher, dass das X20-Modul vollständig im Rückwand-Steckplatz verriegelt ist. Vibrationen können bei Hochgeschwindigkeits-Encoder-Eingängen zu intermittierendem Signalverlust führen; überprüfen Sie während der Inbetriebnahme, dass die mechanische Verriegelung sicher sitzt.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086367842667,"sku":"X20DC2396","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20dc2396-ktx04fzycak.png?v=1776138179"},{"product_id":"b-r-x20dc4395-encoder-and-counter-module","title":"B\u0026R X20DC4395 Encoder- und Zählermodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DC4395 (X20DC4395)\u003c\/strong\u003e ist ein äußerst vielseitiges digitales Zähler- und Encoder-Schnittstellenmodul aus der B\u0026amp;R X20 Automatisierungsserie. Entwickelt für komplexe Bewegungssteuerungen und hochfrequente Signalerfassung, unterstützt dieses Modul mehrere Betriebsarten, darunter SSI (Synchronous Serial Interface) Absolutwertgeber, inkrementelle AB-Geber, Ereigniszähler und Pulsweitenmodulation (PWM) Signalgebung. Durch die Integration dieser hochpräzisen Funktionen in einem einzigen Modul ermöglicht das X20DC4395 Maschinenbauern, den Schaltschrankplatz zu optimieren und gleichzeitig die Nanosekunden-genaue Synchronisation zu gewährleisten, die für anspruchsvolle Industrieanwendungen wie Robotik, CNC-Bearbeitung und automatisierte Montagelinien erforderlich ist.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas Modul bietet eine hohe Konfigurationsflexibilität, sodass Anwender das Hardwareverhalten über die Softwareumgebung an spezifische Anwendungsanforderungen anpassen können:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEncoder-Schnittstellen:\u003c\/strong\u003e Unterstützt bis zu 2 SSI Absolutwertgeber (24 V), 2 AB inkrementelle Geber (24 V) oder 4 AB inkrementelle Geber (24 V).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZähler-\/PWM-Modi:\u003c\/strong\u003e Konfigurierbar für bis zu 8 unabhängige Ereigniszähler oder 4 PWM-Ausgangskanäle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZeitmessung:\u003c\/strong\u003e Beinhaltet spezialisierte lokale Zeitmessfunktionen, die eine hochpräzise Ereigniszeitstempelung und Intervallüberwachung unabhängig von der Haupt-CPU-Zykluszeit ermöglichen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalverträglichkeit:\u003c\/strong\u003e Vollständig kompatibel mit 24 V Signalpegeln, was eine robuste Störsicherheit in elektrisch störungsintensiven Industrieumgebungen gewährleistet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20DC4395\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eModultyp\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eDigitales Zähler-\/Encoder-Modul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eEingangsmodi\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e2x SSI, 2x\/4x AB inkrementell, 8x Ereigniszähler, 4x PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eVersorgungsspannung\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSpezialfunktionen\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eLokale Zeitmessung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0,3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eVersandgewicht\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eKann ich die PWM-Funktion und die Encoder-Eingänge gleichzeitig verwenden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Betriebsarten des X20DC4395 schließen sich je nach im B\u0026amp;R-Softwareprofil gewählter Konfiguration gegenseitig aus. Sie müssen den spezifischen Modus (z. B. SSI oder PWM) bei der initialen Projektkonfiguration auswählen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist der Vorteil der lokalen Zeitmessfunktionen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie lokale Zeitmessung ermöglicht es dem Modul, Ereignisse oder Signalübergänge mit einer Zeitauflösung zu erfassen, die höher ist als der SPS-Scanzyklus, und bietet so eine überlegene Genauigkeit für Anwendungen wie Hochgeschwindigkeits-Sortierung oder präzises Positionssperren.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenötigt dieses Modul eine externe Signalaufbereitung für SSI-Encoder?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein, das X20DC4395 ist dafür ausgelegt, direkt mit 24 V SSI Absolutwertgebern zu kommunizieren, wodurch der Einsatz von Zwischenverstärkern oder Pegelwandlern entfällt.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbschirmungsanforderungen:\u003c\/strong\u003e Da Encoder-Signale empfindlich gegenüber elektromagnetischen Störungen (EMI) sind, verwenden Sie stets geschirmte verdrillte Leitungen. Stellen Sie sicher, dass die Abschirmung am Schaltschrank-Eintrittspunkt über 360-Grad-Kontakt-EMV-Kabelverschraubungen mit der vorgesehenen Erdungsschiene verbunden ist.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKabellängen:\u003c\/strong\u003e Für hochfrequente AB inkrementelle Encoder-Signale sollten die Kabellängen unter 20 Metern gehalten werden. Bei längeren Strecken muss der Signalspannungsabfall innerhalb der vom Modul spezifizierten Toleranz bleiben.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErdung und Störsicherheit:\u003c\/strong\u003e Um die Präzision der Zählerfunktionen zu gewährleisten, ist ein niederohmiger Erdpfad zwischen dem Encoder-Gehäuse und dem Maschinenchassis sicherzustellen. Vermeiden Sie es, Encoder-Signalkabel parallel zu Hochspannungs-Motorleitungen oder Frequenzumrichter-Ausgangskabeln zu verlegen.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086367908203,"sku":"X20DC4395","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20dc4395-ta3o4faby4x.png?v=1776138180"},{"product_id":"b-r-x20do8332-digital-output-module","title":"B\u0026R X20DO8332 Digitales Ausgangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DO8332 (X20DO8332)\u003c\/strong\u003e ist ein leistungsstarkes Digitalausgangsmodul, das in das B\u0026amp;R X20 Automatisierungssystem integriert ist und für anspruchsvolle industrielle Schaltaufgaben entwickelt wurde. Dieses Modul verfügt über 8 unabhängige Digitalausgänge, die jeweils 24 VDC bei einem Quellstrom von 2 A verarbeiten können. Durch die direkte Stromversorgung am Modul vereinfacht der X20DO8332 die Verdrahtung im Schaltschrank und reduziert den Bedarf an externen Stromverteilungsblöcken. Es ist darauf ausgelegt, eine hohe Betriebssicherheit in der Maschinensteuerung, Robotik und komplexen Prozessautomatisierung zu gewährleisten, wodurch das Risiko von ausgangsbedingten Systemausfällen effektiv minimiert und kostspielige Ausfallzeiten reduziert werden.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDie Architektur des X20DO8332 ist für 1-Draht-Verbindungssysteme optimiert, was die Verkabelungskomplexität und den Platzbedarf im Schaltschrank erheblich reduziert. Jeder der 8 Kanäle ist mit einer ausgeklügelten Schutzschaltung ausgestattet, um induktive Lasten, wie sie häufig bei Relaisspulen, Magnetventilen und Schützen vorkommen, sicher zu handhaben.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLastenhandhabung:\u003c\/strong\u003e Unterstützt bis zu 2 A pro Ausgang, ideal für die direkte Steuerung von stromstarken Aktoren.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersorgungslogik:\u003c\/strong\u003e Die direkte Stromversorgung auf Modulebene vereinfacht die Verdrahtungsarchitektur und sorgt dafür, dass die Ausgangsspannung auch bei Schaltvorgängen mit hoher Last stabil bleibt.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKompaktes Design:\u003c\/strong\u003e Als Standard-X20-Scheibenmodul fügt es sich nahtlos in bestehende Backplane-Konfigurationen ein und unterstützt Hot-Swapping für schnelle Wartung, ohne das restliche I\/O-Netzwerk zu stören.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20DO8332\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAnzahl der Ausgänge\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSpannung\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eMaximaler Strom pro Ausgang\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e2 A (Quelle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eAnschlusstyp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e1-Draht\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eStromversorgung\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eDirekt am Modul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e0,2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eVersandgewicht\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWelche Vorteile bietet das 1-Draht-Verbindungsdesign beim X20DO8332?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie 1-Draht-Verbindung minimiert die Anzahl der für Ausgangssignale benötigten Leiter, was die Verdrahtungszeit, Kabelkosten und potenzielle Fehlerquellen im Schaltschrank erheblich reduziert.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses Modul induktive Lasten sicher schalten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, der X20DO8332 ist für induktive Lasten ausgelegt; bei stark induktiven Anwendungen wird jedoch empfohlen, externe Freilaufdioden oder Überspannungsschutzgeräte zu verwenden, falls die Last die interne Unterdrückungskapazität des Moduls überschreitet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenötigt der X20DO8332 eine externe Stromversorgung für die Ausgänge?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul ist für die direkte Versorgung ausgelegt; stellen Sie bitte sicher, dass die 24 VDC-Versorgung ausreichend für den Gesamtstrom aller aktiven Ausgänge dimensioniert ist, um Spannungsabfälle oder thermische Überlastungen zu vermeiden.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLastberechnung:\u003c\/strong\u003e Berechnen Sie bei der Konfiguration des Ausgangsbanks den Gesamtstrom aller 8 Ausgänge, wenn diese gleichzeitig geschaltet werden. Stellen Sie sicher, dass die Summe der Ströme die maximale Strombelastbarkeit der Versorgungsklemmen des Moduls nicht überschreitet, um Überhitzung zu vermeiden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKabelabschirmung:\u003c\/strong\u003e Obwohl es sich um ein DC-Ausgangsmodul handelt, sollten bei Lasten, die mehr als 10 Meter entfernt sind, abgeschirmte Kabel verwendet werden. Schließen Sie die Abschirmung am Schrankerdungsschiene an, um elektromagnetische Störungen (EMI) durch schnelles Schalten zu minimieren.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermisches Management:\u003c\/strong\u003e Bei Dauerbetrieb mit Volllast erzeugt das Modul Wärme. Halten Sie einen Mindestabstand von 10 mm zu anderen wärmeintensiven Komponenten im X20-Rack ein. Überschreitet die Umgebungstemperatur im Schaltschrank 40 °C, wird eine Zwangsbelüftung empfohlen, um die Lebensdauer der elektronischen Ausgangstreiber zu verlängern.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086368072043,"sku":"X20DO8332","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20do8332-l5ynq0rekaz.png?v=1776138193"},{"product_id":"b-r-x20if1086-2-interface-module","title":"B\u0026R X20IF1086-2 Schnittstellenmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20IF1086-2 (X20IF1086-2)\u003c\/strong\u003e ist ein leistungsstarkes Kommunikationsschnittstellenmodul, das für das B\u0026amp;R X20-System entwickelt wurde und speziell darauf ausgelegt ist, einen nahtlosen Datenaustausch in komplexen industriellen Automatisierungsumgebungen zu gewährleisten. Dieses Modul ist entscheidend für die Aufrechterhaltung der System-Synchronisation in Anwendungen, die von Hochgeschwindigkeits-Verpackungslinien bis hin zu großflächigen Prozesssteuerungen in Chemie- oder Kraftwerken reichen. Durch die Bereitstellung integrierter Busfunktionsdiagnosen und Statusüberwachung dient das X20IF1086-2 als wichtige Komponente zur Verkürzung der Diagnosezeiten und zur Vermeidung kostspieliger, ungeplanter Produktionsausfälle. Sein Design gewährleistet eine robuste Konnektivität und ermöglicht eine effiziente Kommunikation innerhalb verteilter I\/O-Netzwerke.\u003c\/p\u003e\n\u003ch3\u003eTechnische Architektur\u003c\/h3\u003e\n\u003cp\u003eDas X20IF1086-2 ist darauf ausgelegt, die Signalqualität und einen zuverlässigen Datendurchsatz innerhalb des B\u0026amp;R X20-Ökosystems zu optimieren. Die Hardware verfügt über fortschrittliche interne Diagnose-Schaltungen, die sowohl den Modulzustand als auch den Feldbusstatus überwachen. Der Status wird dem Bediener über gut sichtbare Onboard-LEDs angezeigt, während umfassende Diagnosedaten über die B\u0026amp;R-Softwareumgebung zugänglich sind. Dieser zweistufige Überwachungsansatz ermöglicht eine proaktive Wartung, sodass Ingenieure Netzwerkstörungen erkennen und beheben können, bevor sie die Gesamtsteuerlogik beeinträchtigen. Das Modul ist für ein effizientes Energiemanagement ausgelegt und hat einen Stromverbrauch von 1,8 W (bzw. 2 W bei Hardwareversionen vor D0).\u003c\/p\u003e\n\u003ch3\u003eTechnische Spezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20IF1086-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eDiagnose\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eModulstatus und Busfunktion (LED und Software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eStromverbrauch\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1,8 W (rev. \u0026lt;D0: 2 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eVersandgewicht\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e1,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eLieferzeit\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e7 bis 10 Tage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWie interpretiere ich die Status-LEDs am X20IF1086-2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul verfügt über dedizierte LEDs für Modulstatus und Busfunktion. Ein dauerhaft grünes Licht zeigt in der Regel den Normalbetrieb an, während blinkende oder rote Zustände spezifischen Fehlercodes entsprechen, die im offiziellen B\u0026amp;R X20-System-Benutzerhandbuch detailliert beschrieben sind.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst dieses Modul mit älteren X20-Rückplane-Versionen kompatibel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas X20IF1086-2 ist für die X20-Serie konzipiert. Überprüfen Sie jedoch stets Ihre Rückplane-Version und die CPU-Firmware, um die vollständige Funktionskompatibilität sicherzustellen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann ich die Busfunktion aus der Ferne überwachen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, zusätzlich zu den lokalen LED-Anzeigen liefert das Modul umfassende Diagnosedaten direkt an die B\u0026amp;R-Automatisierungssoftware, was eine Fernüberwachung und zentrale Fehlerbehebung von Ihrer Engineering-Station aus ermöglicht.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Betriebshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrität der Busverbindung:\u003c\/strong\u003e Stellen Sie sicher, dass die X20-Rückplane frei von Verschmutzungen ist. Beim Einbau des Schnittstellenmoduls drücken Sie es fest in den Anschlussblock, bis ein hörbares Klicken zu hören ist, um die mechanische Verriegelung vollständig zu gewährleisten und vibrationsbedingte Verbindungsabbrüche zu vermeiden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermische Aspekte:\u003c\/strong\u003e Obwohl das Modul einen niedrigen Stromverbrauch von 1,8 W hat, sollte ein Mindestabstand von 25 mm oberhalb und unterhalb des Moduls im Schaltschrank eingehalten werden, um eine passive Konvektion zu ermöglichen. Vermeiden Sie die Montage des Moduls direkt über wärmeerzeugenden Leistungselektroniken.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnoseprotokoll:\u003c\/strong\u003e Ordnen Sie die Diagnose-Register während der Erstkonfiguration des Projekts stets in der B\u0026amp;R-Software zu. Es wird empfohlen, Fehlerbehandlungsroutinen basierend auf diesen Diagnosebits einzurichten, um bei einem Busunterbruch sofortige Alarme in Ihrem HMI\/SCADA-System auszulösen.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086368235883,"sku":"X20IF1086-2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20if1086-2-c0h3y55wd42.png?v=1776138208"},{"product_id":"b-r-x20di4760-b-r-x20-digital-input-module","title":"B\u0026R X20DI4760 B\u0026R X20 Digitales Eingangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DI4760 (X20DI4760)\u003c\/strong\u003e ist ein hochpräzises Digital-Eingangsmodul aus der B\u0026amp;R X20-Serie, speziell entwickelt für Anwendungen, die die Überwachung von NAMUR-Sensoren erfordern. Dieses Modul verfügt über vier isolierte digitale Eingänge, die offene Leitungen oder Kurzschlüsse erkennen können, und ist somit ein unverzichtbares Bauteil für sicherheitskritische Überwachungen in der Chemie-, Petrochemie- und Hochzuverlässigkeitsfertigung. Durch die Bereitstellung einer Echtzeit-Signalvalidierung minimiert das X20DI4760 das Risiko von Fehlalarmen und verbessert die Diagnosegenauigkeit Ihres Automatisierungssystems.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDie Architektur des X20DI4760 ist darauf ausgelegt, direkt mit NAMUR-konformen Sensoren zu kommunizieren, die häufig in gefährlichen Umgebungen zur Überwachung von Durchfluss, Position und Geschwindigkeit eingesetzt werden. Ein herausragendes Merkmal dieses Moduls ist seine Doppelfunktionalität; jeder der vier Eingänge kann unabhängig als Hochgeschwindigkeits-Zähleingang konfiguriert werden. Diese Flexibilität ermöglicht es Ingenieuren, das Modul sowohl für die Zustandsüberwachung (z. B. Status von Näherungssensoren) als auch für die Messung von Prozessgrößen (z. B. Pulserfassung zur Drehzahlmessung) zu nutzen, ohne zusätzliche Hardware zu benötigen.\u003c\/p\u003e\n\u003cp\u003eDas Modul unterstützt umfassende Signaldianostik und liefert sofortiges Feedback zum Zustand der Sensoren. Durch die Erkennung von Kabelbrüchen oder Kurzschlüssen an der Quelle kann das System einen automatischen Alarm oder eine Sicherheitsabschaltung auslösen, bevor der Prozess beeinträchtigt wird. Dieses Maß an detaillierter Transparenz ist entscheidend, um ungeplante Ausfallzeiten zu reduzieren und die Betriebssicherheit zu gewährleisten.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20DI4760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSerie\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eX20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eModultyp\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eDigital-Eingangsmodul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eEingangskanäle\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSensorstandard\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eNAMUR (EN 60947-5-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eDiagnosefähigkeit\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eErkennung von Leitungsunterbrechung und Kurzschluss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eZählerfunktion\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eJa, pro Kanal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eMontage\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eX20-Busbasis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas sind die Hauptvorteile der Unterstützung von NAMUR-Sensoren?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNAMUR-Sensoren sind so ausgelegt, dass sie Informationen über Stromänderungen übertragen. Dadurch kann das X20DI4760 zwischen einem gültigen Signal und einem beschädigten Kabel (Leitungsunterbrechung oder Kurzschluss) unterscheiden, was mit herkömmlichen binären Digitaleingängen nicht möglich ist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKönnen alle vier Eingänge gleichzeitig als Zähler fungieren?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Jeder der vier Kanäle ist individuell konfigurierbar. Sie können jede Kombination von Eingängen für die Standard-Zustandsüberwachung oder die Hochgeschwindigkeits-Pulserfassung je nach Anwendungsanforderung festlegen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenötigt dieses Modul eine spezielle Busbasis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas X20DI4760 ist für das Standard-X20-System ausgelegt. Stellen Sie sicher, dass es auf einer kompatiblen X20-Busbasis montiert wird, um die elektrische Verbindung zum restlichen Rack zu gewährleisten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie interpretiere ich die Diagnosealarme für dieses Modul?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDiagnosedaten werden über den X20-Systembus an die Steuerung übertragen. In Automation Studio können Sie Software-Register konfigurieren, die bei Erkennung eines Leitungsbruchs oder Kurzschlusses an einem Kanal spezifische Alarme auslösen.\u003c\/p\u003e\n\u003ch3\u003eInstallation und Verdrahtung – Beste Praktiken\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor-Kompatibilität:\u003c\/strong\u003e Stellen Sie sicher, dass Ihre Feldsensoren dem NAMUR-Standard (EN 60947-5-6) entsprechen, bevor Sie sie an das Modul anschließen. Der Anschluss von nicht-NAMUR-Sensoren führt zu fehlerhaften Zustandsanzeigen oder zum Ausfall der Diagnoselogik.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbschirmung:\u003c\/strong\u003e Obwohl NAMUR-Schaltungen von Natur aus robust sind, verwenden Sie abgeschirmte Kabel bei langen Leitungswegen, um elektromagnetische Störungen zu vermeiden, die falsche Pulserfassungen oder Diagnosefehler auslösen könnten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEingangskonfiguration:\u003c\/strong\u003e Achten Sie bei der Einrichtung der Zählerfunktion in der Software darauf, dass die Eingangsfrequenz die Hardwaregrenzen des X20DI4760 nicht überschreitet, um Pulsausfälle zu vermeiden.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086368399723,"sku":"X20DI4760","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20di4760-vobfsqmpt1p.png?v=1776138180"},{"product_id":"b-r-x20ds438a-b-r-x20-io-link-master-module","title":"B\u0026R X20DS438A B\u0026R X20 IO-Link Master Modul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DS438A (X20DS438A)\u003c\/strong\u003e ist ein leistungsstarkes IO-Link-Mastermodul im B\u0026amp;R X20-System, das die Integration von bis zu vier IO-Link-Geräten in ein zentrales Steuerungsnetzwerk ermöglicht. Durch die nahtlose Kommunikation mit intelligenten Sensoren und Aktoren bietet dieses Modul erweiterte Diagnosefunktionen und Fernparametrierung, was die Konfigurationszeit erheblich verkürzt und die Prozessübersicht verbessert. Für anspruchsvolle Industrieumgebungen entwickelt, verfügt es über eine elektrische Trennung zwischen Bus und IO-Link-Schnittstelle, die eine hohe Datenintegrität und Schutz vor elektrischen Störungen in komplexen Automatisierungszellen gewährleistet.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas X20DS438A verwendet eine 3-polige Anschlussarchitektur und unterstützt Standard-Sensorleitungen ohne Schirmung mit einer Länge von bis zu 20 m. Es verfügt über ein robustes Diagnosesystem, das es Bedienern ermöglicht, den Modulstatus, den IO-Link-Betriebszustand und den C\/Q-Kanalstatus sowohl über Hardware-LED-Anzeigen als auch über softwarebasierte Echtzeit-Rückmeldungen zu überwachen.\u003c\/p\u003e\n\u003cp\u003eMit einem B\u0026amp;R-ID-Code von 0xCAC0 wird das Modul nativ von Automation Studio erkannt, was eine schnelle Inbetriebnahme erleichtert. Das Energiemanagement ist eine Stärke des Moduls und liefert bis zu 12 W pro IO-Link-Schnittstelle. Zudem bietet das Modul eine benutzerkonfigurierbare Überlastschutzfunktion, die spezifische Abschaltverzögerungen und -dauern ermöglicht, um Fehlauslösungen zu vermeiden und gleichzeitig die Hardware bei Kurzschlussereignissen zu schützen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20DS438A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSerie\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eX20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eModultyp\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eIO-Link Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSchnittstellen\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4 x IO-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eID-Code\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0xCAC0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eKabellänge\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eMax. 20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eLeistung pro Kanal\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eMax. 12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eIsolation\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eBus zu IO-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eBetriebstemperatur (horizontal)\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e-25 bis 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWelche Kabelanforderungen gelten für die IO-Link-Schnittstellen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerwenden Sie 3-polige Standard-Sensorleitungen. Um eine zuverlässige Kommunikation zu gewährleisten, darf die Kabellänge 20 m nicht überschreiten, mit einer maximalen Leitungs-Kapazität von 3 nF und einem maximalen Schleifenwiderstand von 6 Ohm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie funktioniert der Überlastschutz?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul verfügt über einen elektronischen Kurzschluss- und Überlastschutz. Die Abschaltverzögerung und -dauer sind vollständig softwareseitig konfigurierbar, sodass das System temporäre Einschaltströme verarbeiten kann, ohne den Kanal unnötig abzuschalten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann ich die Moduldatenferndiagnose überwachen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Umfassende Diagnosen zum Modul-Fehler-\/Betriebszustand, IO-Link-Betriebsmodus und C\/Q-Kanalstatus sind über die B\u0026amp;R-Softwareumgebung zugänglich und bieten sofortige Warnungen bei abnormen Prozessbedingungen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelchen Einfluss hat die Montageausrichtung auf die Betriebstemperatur?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAufgrund thermischer Konvektionseigenschaften erlaubt die horizontale Montage einen Betriebstemperaturbereich von -25 bis 60 °C, während die vertikale Montage diesen auf -25 bis 50 °C begrenzt.\u003c\/p\u003e\n\u003ch3\u003eInstallation und Wärmemanagement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermische Überlegungen:\u003c\/strong\u003e Priorisieren Sie stets die horizontale Montage, sofern das Schaltschrankdesign dies zulässt, um die maximale Betriebstemperatur von 60 °C zu erreichen. Stellen Sie sicher, dass das Modul nicht durch Kabelkanäle oder andere Komponenten blockiert wird, die den Luftstrom behindern könnten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKurzschlussschutz:\u003c\/strong\u003e Berücksichtigen Sie bei der Konfiguration des Überlastschutzes den Anlaufstrom Ihrer spezifischen Sensoren. Eine zu kurze Abschaltverzögerung bei hochkapazitiven Sensoren kann während der Einschaltsequenz zu Fehlermeldungen führen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKabelverlegung:\u003c\/strong\u003e Obwohl das Modul ungeschirmte Kabel unterstützt, sollte eine physische Trennung zwischen IO-Link-Leitungen und Hochstrom-Motorkabeln eingehalten werden. Selbst bei elektrischer Trennung sorgt eine Minimierung der Nähe zu hochfrequenten elektromagnetischen Störquellen für die stabilste IO-Link-Kommunikation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086368498027,"sku":"X20DS438A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ds438a-bna33n3qqkq.png?v=1776138201"},{"product_id":"b-r-x20bb81-b-r-x20-bus-base-module","title":"B\u0026R X20BB81 B\u0026R X20 Bus-Basismodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20BB81 (X20BB81)\u003c\/strong\u003e ist ein grundlegendes Bus-Basismodul, das für die B\u0026amp;R X20-Systemarchitektur entwickelt wurde. Diese Komponente dient als physikalisches und elektrisches Rückgrat für dezentrale I\/O-Konfigurationen und verfügt über einen dedizierten Erweiterungssteckplatz zur Systemskalierbarkeit. Durch die Bereitstellung der mechanischen Schnittstelle und elektrischen Verbindung für Basismodule (wie BC- oder HB-Controller), Zusatzmodule (IF oder HB) und Versorgungsmodule ist der X20BB81 unerlässlich für die Aufrechterhaltung eines strukturierten und zuverlässigen Schaltschranklayouts. Seine Integration minimiert effektiv die Installationskomplexität und unterstützt schnelle Wartungszyklen in hochverfügbaren Industrieumgebungen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDer X20BB81 ist so konstruiert, dass er die Modularität des X20-Systems unterstützt. Das Basismodul dient als Träger für die verschiedenen I\/O- und Kommunikationselektroniken und leitet Strom- und Datensignale über den internen X20-Rückplane-Bus. Der enthaltene Erweiterungssteckplatz ermöglicht die flexible Hinzufügung von Schnittstellen- oder Zusatzstrommodulen, wodurch Systemintegratoren die Hardwarefunktionalität an spezifische Prozessanforderungen anpassen können, ohne die Kernverkabelung zu verändern.\u003c\/p\u003e\n\u003cp\u003eDie Einheit wird mit sowohl linken als auch rechten Endabdeckungen geliefert, die eine vollständige mechanische Baugruppe und Schutz gegen Umwelteinflüsse gewährleisten. Dieser modulare Ansatz ermöglicht nahtloses Hot-Swapping und Wartung, da das Bus-Basismodul auf der DIN-Schiene fixiert bleibt, während die elektronischen Module unabhängig gewartet werden können.\u003c\/p\u003e\n\u003ch3\u003eTechnische Spezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20BB81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSerie\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eX20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eModultyp\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eBus-Basismodul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eErweiterungssteckplätze\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eMontage\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eDIN-Schiene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eUnterstützte Komponenten\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eBasismodule, Zusatzmodule, Versorgungsmodule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eIm Lieferumfang enthaltenes Zubehör\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eLinke und rechte Endabdeckungen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWelche spezifischen Module können auf dem X20BB81 montiert werden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer X20BB81 ist kompatibel mit einer Vielzahl von B\u0026R X20-Komponenten, einschließlich Basismodulen (z. B. Buscontroller), Zusatzschnittstellenmodulen und verschiedenen Versorgungsmodulen, die für die Stromverteilung im System benötigt werden.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSind die Endabdeckplatten für den Betrieb erforderlich?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, die Endabdeckplatten sind sowohl für die mechanische Stabilität als auch für die erforderliche IP-Schutzart der Anschlussbaugruppe notwendig, um elektrische Komponenten vor Staub und Schmutz zu schützen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst es möglich, das elektronische Modul zu wechseln, ohne die Busbasis zu entfernen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, das X20-System ist so konzipiert, dass die elektronischen Module aus der Busbasis entfernt werden können, ohne die Feldverkabelung oder die Busbasis selbst zu beeinträchtigen, was die Ausfallzeiten bei Wartungsarbeiten erheblich reduziert.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersorgt der X20BB81 die Module mit Strom?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Busbasis fungiert als Verteilermodul für die von den X20-Netzteilen bereitgestellte Energie. Sie leitet die erforderlichen Spannungen an die montierten Basis- oder Zusatzmodule weiter, um einen stabilen Betrieb zu gewährleisten.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und mechanische Richtlinien\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHutschienenmontage:\u003c\/strong\u003e Stellen Sie sicher, dass die Hutschiene sicher und waagerecht im Schaltschrank montiert ist. Klicken Sie den X20BB81 auf die Schiene, bis ein hörbares Klicken zu vernehmen ist, das das Einrasten der Verriegelung bestätigt.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulausrichtung:\u003c\/strong\u003e Beim Einsetzen von Basis- oder Zusatzmodulen stellen Sie sicher, dass diese perfekt mit den Führungsschienen des X20BB81 ausgerichtet sind. Üben Sie keinen übermäßigen Druck aus; die Steckstiftkontakte sollten sich reibungslos verbinden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEndabdeckung Montage:\u003c\/strong\u003e Befestigen Sie immer die mitgelieferten Endabdeckplatten, nachdem das letzte Modul installiert wurde. Diese Platten verhindern seitliche Bewegungen der Module auf der Hutschiene und bieten den notwendigen physischen Schutz für die Rückwandkontakte.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibrationsbeständigkeit:\u003c\/strong\u003e Bei Anwendungen mit stark vibrierenden Geräten stellen Sie sicher, dass die Verriegelungsmechanismen am Modulgehäuse vollständig eingerastet sind, und erwägen Sie die Verwendung von Endklemmen auf der Hutschiene, um seitliche Verschiebungen zu verhindern.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20BB81 (X20BB81)\u003c\/strong\u003e ist ein grundlegendes Bus-Basismodul, das für die B\u0026amp;R X20-Systemarchitektur entwickelt wurde. Diese Komponente dient als physikalisches und elektrisches Rückgrat für dezentrale I\/O-Konfigurationen und verfügt über einen dedizierten Erweiterungssteckplatz zur Systemskalierbarkeit. Durch die Bereitstellung der mechanischen Schnittstelle und elektrischen Verbindung für Basismodule (wie BC- oder HB-Controller), Zusatzmodule (IF oder HB) und Versorgungsmodule ist der X20BB81 unerlässlich für die Aufrechterhaltung eines strukturierten und zuverlässigen Schaltschranklayouts. Seine Integration minimiert effektiv die Installationskomplexität und unterstützt schnelle Wartungszyklen in hochverfügbaren Industrieumgebungen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDer X20BB81 ist so konstruiert, dass er die Modularität des X20-Systems unterstützt. Das Basismodul dient als Träger für die verschiedenen I\/O- und Kommunikationselektroniken und leitet Strom- und Datensignale über den internen X20-Rückplane-Bus. Der enthaltene Erweiterungssteckplatz ermöglicht die flexible Hinzufügung von Schnittstellen- oder Zusatzstrommodulen, wodurch Systemintegratoren die Hardwarefunktionalität an spezifische Prozessanforderungen anpassen können, ohne die Kernverkabelung zu verändern.\u003c\/p\u003e\n\u003cp\u003eDie Einheit wird mit sowohl linken als auch rechten Endabdeckungen geliefert, die eine vollständige mechanische Baugruppe und Schutz gegen Umwelteinflüsse gewährleisten. Dieser modulare Ansatz ermöglicht nahtloses Hot-Swapping und Wartung, da das Bus-Basismodul auf der DIN-Schiene fixiert bleibt, während die elektronischen Module unabhängig gewartet werden können.\u003c\/p\u003e\n\u003ch3\u003eTechnische Spezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20BB81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSerie\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eX20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eModultyp\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eBus-Basismodul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eErweiterungssteckplätze\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eMontage\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eDIN-Schiene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eUnterstützte Komponenten\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eBasismodule, Zusatzmodule, Versorgungsmodule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eIm Lieferumfang enthaltenes Zubehör\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eLinke und rechte Endabdeckungen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWelche spezifischen Module können auf dem X20BB81 montiert werden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer X20BB81 ist kompatibel mit einer Vielzahl von B\u0026R X20-Komponenten, einschließlich Basismodulen (z. B. Buscontroller), Zusatzschnittstellenmodulen und verschiedenen Versorgungsmodulen, die für die Stromverteilung im System benötigt werden.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSind die Endabdeckplatten für den Betrieb erforderlich?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, die Endabdeckplatten sind sowohl für die mechanische Stabilität als auch für die erforderliche IP-Schutzart der Anschlussbaugruppe notwendig, um elektrische Komponenten vor Staub und Schmutz zu schützen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst es möglich, das elektronische Modul zu wechseln, ohne die Busbasis zu entfernen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, das X20-System ist so konzipiert, dass die elektronischen Module aus der Busbasis entfernt werden können, ohne die Feldverkabelung oder die Busbasis selbst zu beeinträchtigen, was die Ausfallzeiten bei Wartungsarbeiten erheblich reduziert.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersorgt der X20BB81 die Module mit Strom?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Busbasis fungiert als Verteilermodul für die von den X20-Netzteilen bereitgestellte Energie. Sie leitet die erforderlichen Spannungen an die montierten Basis- oder Zusatzmodule weiter, um einen stabilen Betrieb zu gewährleisten.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und mechanische Richtlinien\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHutschienenmontage:\u003c\/strong\u003e Stellen Sie sicher, dass die Hutschiene sicher und waagerecht im Schaltschrank montiert ist. Klicken Sie den X20BB81 auf die Schiene, bis ein hörbares Klicken zu vernehmen ist, das das Einrasten der Verriegelung bestätigt.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulausrichtung:\u003c\/strong\u003e Beim Einsetzen von Basis- oder Zusatzmodulen stellen Sie sicher, dass diese perfekt mit den Führungsschienen des X20BB81 ausgerichtet sind. Üben Sie keinen übermäßigen Druck aus; die Steckstiftkontakte sollten sich reibungslos verbinden.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEndabdeckung Montage:\u003c\/strong\u003e Befestigen Sie immer die mitgelieferten Endabdeckplatten, nachdem das letzte Modul installiert wurde. Diese Platten verhindern seitliche Bewegungen der Module auf der Hutschiene und bieten den notwendigen physischen Schutz für die Rückwandkontakte.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibrationsbeständigkeit:\u003c\/strong\u003e Bei Anwendungen mit stark vibrierenden Geräten stellen Sie sicher, dass die Verriegelungsmechanismen am Modulgehäuse vollständig eingerastet sind, und erwägen Sie die Verwendung von Endklemmen auf der Hutschiene, um seitliche Verschiebungen zu verhindern.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086368596331,"sku":"X20BB81","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20bb81-t2ds4flq3vu.png?v=1776138137"},{"product_id":"b-r-x20at2402-b-r-x20-temperature-measurement-module","title":"B\u0026R X20AT2402 B\u0026R X20 Temperaturmessmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20AT2402 (X20AT2402)\u003c\/strong\u003e ist ein spezialisiertes Temperaturmessmodul im B\u0026amp;R X20-System, das für hochpräzise Thermoelement-Datenerfassung entwickelt wurde. Dieses Gerät bietet zwei dedizierte Eingänge für Thermoelement-Sensoren und ist somit eine unverzichtbare Komponente für die thermische Prozesssteuerung in Branchen wie Kunststoffspritzguss, Ofenmanagement und Präzisionsfertigung. Durch die Nutzung einer 16-Bit-Digitalwandlerauflösung gewährleistet das X20AT2402 eine sehr feine Signalverarbeitung, die entscheidend ist, um strenge Temperaturtoleranzen einzuhalten und Ausfallzeiten in automatisierten Regelkreisen zu minimieren.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDas Modul ist für die nahtlose Integration in die dezentrale X20-I\/O-Architektur ausgelegt. Es unterstützt eine breite Palette von Thermoelementtypen gemäß der Norm EN 60584, was Flexibilität bei der Sensorauswahl entsprechend den Prozess-Temperaturanforderungen ermöglicht.\u003c\/p\u003e\n\u003cp\u003eKommunikation und Statusüberwachung werden durch integrierte Statusanzeigen vereinfacht, die Echtzeit-Feedback zur I\/O-Funktion pro Kanal, zum Gesamtbetriebszustand und zur Modulgesundheit bieten. Mit einem B\u0026amp;R-ID-Code von 0x1BA8 wird das Modul automatisch von der B\u0026amp;R Automation Studio-Software erkannt, was die Konfiguration und Inbetriebnahme erleichtert. Die hochauflösende 16-Bit A\/D-Wandlung minimiert Signalrauschen und liefert auch in elektrisch störungsintensiven Industrieumgebungen ein stabiles digitales Ausgangssignal für die Mastersteuerung.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eMerkmal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20AT2402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMarke\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSerie\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eX20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eModultyp\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eTemperaturmessung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eEingangskanäle\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eEingangstyp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eThermoelement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eAuflösung\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e16-Bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eSensorstandard\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eEN 60584\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eID-Code\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e0x1BA8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eStatusanzeigen\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003ePro Kanal, Betriebszustand, Modul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eGewicht\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e1,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWelche Thermoelementtypen sind mit dem X20AT2402 kompatibel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul unterstützt gängige Thermoelementtypen gemäß der Norm EN 60584. Bitte konsultieren Sie die spezifischen Software-Konfigurationseinstellungen in Automation Studio, um den passenden Sensortyp für Ihre Anwendung auszuwählen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie wirkt sich die 16-Bit-Auflösung auf die Messgenauigkeit aus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie 16-Bit-Digitalwandlung bietet eine sehr hohe Granularität, wodurch das Modul kleinste Temperaturänderungen erfassen kann, die bei Geräten mit geringerer Auflösung verloren gehen würden. Dies gewährleistet eine bessere Regelung von Heizelementen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses Modul in explosionsgefährdeten Bereichen eingesetzt werden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul ist für Standard-Industriesteuerschränke ausgelegt. Wenn Ihre Anwendung explosionsgefährdete Zonen umfasst, stellen Sie sicher, dass es in einem geeigneten explosionsgeschützten oder NEMA-zertifizierten Gehäuse installiert wird.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie behebe ich Fehler, wenn ein Kanal eine Störung anzeigt?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNutzen Sie die integrierten Status-LEDs, um den betroffenen Kanal zu isolieren. Überprüfen Sie die Unversehrtheit der Thermoelementverkabelung und stellen Sie sicher, dass der Sensor nicht unterbrochen ist. Prüfen Sie die Software-Diagnose im B\u0026amp;R-Controller auf spezifische Fehlercodes, die mit der ID 0x1BA8 verknüpft sind.\u003c\/p\u003e\n\u003ch3\u003eInstallations- und Verkabelungshinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermoelement-Polung:\u003c\/strong\u003e Stellen Sie sicher, dass die positiven und negativen Leitungen des Thermoelements genau gemäß dem Anschlussdiagramm verbunden sind. Eine vertauschte Polung führt zu fehlerhaften Messwerten, die oft eine Temperaturabsenkung anzeigen, obwohl die tatsächliche Temperatur steigt.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKaltstellenkompensation:\u003c\/strong\u003e Das X20AT2402 verwaltet die Kaltstellenkompensation intern. Vermeiden Sie die Installation des Moduls in der Nähe von extremen Wärmequellen oder direktem Kühlluftstrom, da starke Temperaturgradienten an den Modulanschlüssen die Kompensationsgenauigkeit beeinträchtigen können.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalqualität:\u003c\/strong\u003e Aufgrund der niedrigen Millivolt-Ausgangsspannung von Thermoelementen sollten die Signalleitungen getrennt von Hochspannungsleitungen und Motorantriebskabeln verlegt werden, um elektromagnetische Störungen (EMI) zu vermeiden. Verwenden Sie nach Möglichkeit verdrillte, geschirmte Thermoelement-Verlängerungskabel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086368825707,"sku":"X20AT2402","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20at2402-c5yll3sungq.png?v=1776138132"},{"product_id":"b-r-x20sc2212-x20-system-safe-digital-mixed-i-o-module","title":"B\u0026R X20SC2212 X20 System Sicheres Digitales Misch-E\/A-Modul","description":"\u003cp\u003eDas \u003cstrong\u003eB\u0026amp;R X20SC2212\u003c\/strong\u003e, Teilenummer \u003cstrong\u003eX20SC2212\u003c\/strong\u003e, ist ein sicherheitsorientiertes digitales Mixed-I\/O-Modul, das für die Integration in die X20-System-Rückplane-Kommunikationsarchitektur zur Ausführung von fehlersicherer Steuerungslogik entwickelt wurde. Das elektronische Modul verfügt über 6 sichere digitale Eingänge vom Typ A, die mit 6 dedizierten Impulsausgängen zur Überwachung von Querschlussfehlern gekoppelt sind, sowie 2 sichere digitale Ausgänge vom Typ B1 mit 24 VDC und 0,5 A. Die Betätigung und das Schaltverhalten der Sicherheitsausgänge nutzen ein Output Signal Switching Device (OSSD)-Design mit einer Diagnosetest-Impulsbreite von weniger als 500 µs, um schnelle Reaktionszeiten bei Sicherheitsanforderungen zu gewährleisten. Die Stromversorgung der internen Schaltung erfolgt über eine nominale 24 VDC-Versorgung mit integrierter Verpolungsschutzfunktion, um Schäden an Bauteilen durch falsche elektrische Installation zu verhindern.\u003c\/p\u003e\n\u003ch3\u003eHardware-Spezifikationen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModultyp\u003c\/strong\u003e: Sicherheitsrelevantes digitales Mixed-I\/O-Modul\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEingangskonfiguration\u003c\/strong\u003e: 6 sichere digitale Eingänge vom Typ A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAusgangskonfiguration\u003c\/strong\u003e: 2 sichere digitale Ausgänge vom Typ B1, 6 Impulsausgänge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominalspannung\u003c\/strong\u003e: 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZulässiger Spannungsbereich\u003c\/strong\u003e: 20,4 bis 28,8 VDC (24 VDC -15 % \/ +20 %)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigitaler Ausgangsstrom\u003c\/strong\u003e: 0,5 A pro Kanal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOSSD-Impulsbreite\u003c\/strong\u003e: \u0026lt;500 µs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrierter Schutz\u003c\/strong\u003e: Verpolungsschutz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBetriebsfeuchtigkeitsbereich\u003c\/strong\u003e: 5 bis 95 %, nicht kondensierend\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLagerfeuchtigkeitsbereich\u003c\/strong\u003e: 5 bis 95 %, nicht kondensierend\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransportfeuchtigkeitsbereich\u003c\/strong\u003e: 5 bis 95 %, nicht kondensierend\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e: 2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Hinweise\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZyklischer Datenaustausch über die X20-Rückplane überträgt das Sicherheits-I\/O-Image mittels des openSAFETY-Protokolls, um deterministische Kommunikationszeiten sicherzustellen.\u003c\/li\u003e\n\u003cli\u003eDie 6 Impulsausgänge senden spezifische Testmuster, die an die 6 sicheren digitalen Eingänge vom Typ A zurückgeführt werden, um kontinuierlich die physikalische Leitungsintegrität zu überprüfen und Kurzschlüsse zwischen Kanälen oder zu externen Potenzialen zu diagnostizieren.\u003c\/li\u003e\n\u003cli\u003eSichere digitale Ausgänge vom Typ B1 führen interne Dual-Kanal-Überwachungssequenzen aus, um Bauteilfehler zu erkennen und gewährleisten, dass das Modul bei einem nicht behebbaren Fehler in einen definierten sicheren Zustand übergeht.\u003c\/li\u003e\n\u003cli\u003eDas Betriebsfenster der Versorgungsspannung ist strikt auf 20,4 bis 28,8 VDC begrenzt; jede Abweichung außerhalb dieses Bereichs führt zu einem Unter- oder Überspannungsdiagnosefehler, der die Sicherheitsausgänge deaktiviert.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeldrichtlinien\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRückplane-Kommunikationsabschirmung\u003c\/strong\u003e: Stellen Sie sicher, dass die X20-Bus-Basis-Komponenten sicher auf der DIN-Schiene eingerastet sind, um eine niederohmige Erdung über die lokalen Rückplane-Kommunikationssegmente zu gewährleisten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKabelverlegung und Trennung\u003c\/strong\u003e: Verlegen Sie Sicherheits-Sensor- und Aktuatorleitungen in separaten Kabelkanälen getrennt von Starkstrom-AC- oder Frequenzumrichterleitungen, um elektromagnetische Störungen auf den OSSD-Impulsleitungen zu minimieren.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchirmungserdung\u003c\/strong\u003e: Erden Sie alle geschirmten Kabel für entfernte Sicherheitssensoren direkt am Eintrittspunkt des Schaltschrankgehäuses über eine niederohmige Erdungsschiene.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteckverbinder-Isolierung und -Anschluss\u003c\/strong\u003e: Stellen Sie sicher, dass alle Feldverdrahtungen mit korrektem Leiterquerschnitt und gecrimpten Aderendhülsen ausgeführt sind, um eine gleichmäßige Kontaktkraft in der Klemmenanordnung zu gewährleisten.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische \u0026amp; Beschaffungs-FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFrage\u003c\/strong\u003e: Ist das Sicherheitsmodul X20SC2212 im aktiven X20-I\/O-Chassis-Segment hot-swap-fähig?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAntwort\u003c\/strong\u003e: Ja, das dreiteilige modulare Design des X20-Systems ermöglicht den Hot-Swap des elektronischen Moduls, ohne die Klemmenverdrahtung zu trennen oder die Rückplane-Kommunikationsschleife benachbarter Module zu unterbrechen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrage\u003c\/strong\u003e: Welche Firmware-Anforderungen gelten beim Austausch einer älteren Hardware-Revision dieses Moduls?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAntwort\u003c\/strong\u003e: Die Firmware-Kompatibilität wird über die Automatisierungssoftware-Plattform verwaltet, die die Sicherheitskonfigurations-Checksumme abgleicht, um eine vollständige funktionale Übereinstimmung sicherzustellen, bevor der zyklische Datenaustausch wieder aufgenommen wird.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrage\u003c\/strong\u003e: Welche physischen Inhalte sind im Lieferumfang der spezifischen Teilenummer X20SC2212 enthalten?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAntwort\u003c\/strong\u003e: Das Paket enthält das brandneue originale elektronische Modul; die passende X20-Bus-Basis und der X20-Frontklemmenblock müssen als separate Zubehörteile bestellt werden, um die mechanische Installation abzuschließen.\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369055083,"sku":"X20SC2212","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20sc2212-texbdoqgl3b.png?v=1776138220"},{"product_id":"b-r-x20mk0201-x20-safekey-memory-module","title":"B\u0026R X20MK0201 X20 SafeKEY Speichermodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20MK0201 (X20MK0201)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein spezialisiertes SafeKEY-Speichermodul, das für die B\u0026amp;R X20SL80xx Serie von Sicherheitscontrollern entwickelt wurde. Mit 2 MB dediziertem Anwendungsspeicher dient diese Komponente als sicherer Hardware-Token für sicherheitskritische Automatisierungssysteme. Es gewährleistet die Integrität des sicherheitszertifizierten Anwendungscodes und vereinfacht die Inbetriebnahme der Maschine oder den Austausch des Controllers, indem es projektspezifische Sicherheitskonfigurationen speichert. Das Modul ist für langfristige industrielle Zuverlässigkeit ausgelegt und garantiert 100.000 Lösch-\/Schreibzyklen, was es zu einer robusten Lösung für Umgebungen macht, die häufige Updates und dauerhafte Betriebssicherheit in sicherheitsgerichteten Systemen erfordern.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieses Modul fungiert als sichere Speicher-Schnittstelle, die direkt mit der Sicherheitscontroller-Architektur verbunden ist und so die Codeauthentizität und Konfigurationsstabilität sicherstellt.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnwendungssicherheit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDas SafeKEY fungiert als hardwarebasierter Sicherheitstoken, der die Sicherheitsanwendung kryptografisch an die X20SL80xx Sicherheits-Hardware bindet, um nur autorisierte Codeausführung zu gewährleisten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpeicherlebensdauer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFür den häufigen Einsatz ausgelegt, unterstützt der 2 MB Flash-Speicher bis zu 100.000 Schreib-\/Löschzyklen und bietet eine zuverlässige Basis für die Bereitstellung und Wartung von Sicherheitsprojekten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontageflexibilität:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVollständig für horizontale und vertikale Einbaulagen zugelassen, was eine flexible Integration in sicherheitszertifizierte Steuergehäuse ermöglicht.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUmweltresistenz:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMit der Schutzart IP20 ist das Modul für den Einsatz in Standard-Elektroschalttafeln geeignet. Es unterstützt den Betrieb bis zu 2000 Metern Höhe ohne Leistungsabfall; bei Installationen oberhalb dieses Werts ist pro 100 Meter eine Absenkung der Umgebungstemperatur um 0,5 °C erforderlich, um die thermische Stabilität zu gewährleisten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20MK0201\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModultyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 SafeKEY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKompatibilität\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20SL80xx Serie\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpeichergröße\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSchreib-\/Löschzyklen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100.000 garantiert\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSchutzart\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMontage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal und Vertikal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHöhenbegrenzung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 m (Abschaltung darüber)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industriehardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist die Funktion des SafeKEY im X20SL80xx Sicherheitscontroller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer SafeKEY enthält die sicherheitsrelevante Anwendungslogik und Systemkonfiguration. Er ist unerlässlich, damit der Controller in den „Run“-Zustand wechseln kann. Er verhindert unautorisierte Änderungen und stellt sicher, dass das Sicherheitsintegritätslevel (SIL) der Maschine durch hardwareseitige Bindung der Anwendung an den Controller erhalten bleibt.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst das X20MK0201 mit anderen SafeKEY-Modellen austauschbar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas X20MK0201 ist für die X20SL80xx Serie konzipiert. Obwohl es andere SafeKEY-Module mit unterschiedlichen Speicherkapazitäten gibt, müssen Sie sicherstellen, dass die gewählte Modulkapa­zität (2 MB) für die Größe Ihres spezifischen Sicherheitsprojekts ausreicht. Überprüfen Sie stets die Projektanforderungen in Automation Studio vor der Inbetriebnahme.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann ich den SafeKEY entfernen, während die Sicherheits-SPS aktiv ist?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein. Das Entfernen des SafeKEY während des Betriebs führt zum Verlust der Kommunikation mit der Sicherheitsanwendung, wodurch der Controller einen sicherheitsrelevanten Stopp oder einen kritischen Fehler auslöst. Schalten Sie das System immer vollständig spannungsfrei, bevor Sie das Speichermodul ein- oder ausbauen.\u003c\/p\u003e\n\u003ch3\u003eFeldinbetriebnahme und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eUmgang mit elektrostatischer Entladung (ESD)\u003c\/h3\u003e\n\u003cp\u003eDer SafeKEY enthält empfindlichen Flash-Speicher. Handhaben Sie das Modul ausschließlich an den Kanten und vermeiden Sie das Berühren der Pins oder internen Kontakte. ESD-Schäden führen nicht immer sofort zu einem Ausfall, können jedoch latente Bitfehler verursachen, die während des Betriebs intermittierende Sicherheitsfehler auslösen.\u003c\/p\u003e\n\u003ch3\u003eThermisches Management in großer Höhe\u003c\/h3\u003e\n\u003cp\u003eBei Einsätzen an Standorten über 2000 Metern über dem Meeresspiegel (z. B. Hochgebirgsanlagen oder industrielle Standorte in den Bergen) stellen Sie sicher, dass die Belüftung des Schaltschranks optimiert ist. Für je 100 Meter über der 2000-Meter-Grenze müssen Sie die maximal zulässige Umgebungstemperatur um 0,5 °C senken, um den sicheren thermischen Betrieb des Moduls zu gewährleisten.\u003c\/p\u003e\n\u003ch3\u003eVerifikation und Diagnoseprüfungen\u003c\/h3\u003e\n\u003cp\u003eNach dem ersten Laden eines Sicherheitsprojekts führen Sie eine obligatorische Prüfsummenverifikation mit den B\u0026amp;R-Diagnosetools in Automation Studio durch. Ein erfolgreicher Wechsel in den „Run“-Modus zeigt an, dass Schlüssel und Controller synchronisiert sind. Meldet das Modul beim Start speicherbezogene Alarme, überprüfen Sie die korrekte Sitzposition des Moduls und die Integrität der Projektdatei; versuchen Sie nicht, diese Alarme zu löschen, ohne den zugrunde liegenden Hardwarestatus zu bestätigen.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369218923,"sku":"X20MK0201","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20mk0201-nbqggb0asik.png?v=1776138210"},{"product_id":"b-r-x20dof322-x20-16-channel-digital-output-module","title":"B\u0026R X20DOF322 X20 16-Kanal Digital-Ausgangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DOF322 (X20DOF322)\u003c\/strong\u003e ist ein Digitalausgangsmodul mit hoher Dichte, das speziell für die modulare B\u0026amp;R X20 Systemarchitektur entwickelt wurde. Es ist für die effiziente Übertragung von Steuersignalen in der industriellen Fertigung konzipiert – einschließlich automatisierter Montagelinien, Hochgeschwindigkeits-Materialhandling und Mehrachsen-Peripheriesteuerung. Dieses Modul bietet 16 unabhängige digitale Ausgangskanäle. Jeder Kanal ist für eine Source-Verdrahtung mit einer 1-Draht-Verbindungstopologie ausgelegt, was die Verkabelung im Schaltschrank erheblich vereinfacht. Um eine robuste Leistung in anspruchsvollen Umgebungen zu gewährleisten, verfügt das Modul über integrierten thermischen Abschaltschutz, eingebaute Freilaufdioden zur Handhabung induktiver Lasten sowie eine Echtzeit-Diagnoseüberwachung, was es zu einer zuverlässigen Lösung für kritische Verriegelungssequenzen und Aktuatorsteuerungen macht.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieses Modul vereint hohe Ausgangsdichte mit fortschrittlichen Diagnose- und Schutzfunktionen, um die Systemverfügbarkeit und die Lebensdauer der Hardware zu maximieren.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHohe Schaltausgangsdichte:\u003c\/strong\u003e Integriert 16 sourcing FET-Ausgänge in einem einzigen Modul-Segment und bietet so ein effizientes Verhältnis von Ausgangskanälen zu Bauraum für kompakte Steuerungspanels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrierter Schutz:\u003c\/strong\u003e Verfügt über eine integrierte thermische Abschaltung bei Überstrom- oder Kurzschlussbedingungen mit einem automatischen Rücksetzzyklus von ca. 10 ms (abhängig von der Modultemperatur).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInduktive Lastverwaltung:\u003c\/strong\u003e Ausgestattet mit einer internen Freilaufdiode (Clamping bei typ. 45 VDC), die induktive Schalttransienten effektiv abfängt und die Ausgangsstufe beim Ansteuern von Magnetventilen oder Schützen schützt.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFortschrittliche Diagnostik:\u003c\/strong\u003e Bietet kanalbezogenen Diagnose-Status mit einer 10 ms Verzögerung zur Fehlerfilterung und stellt den „Modul Lauf-\/Fehler“-Status sowohl über LED-Anzeigen als auch Software-Register bereit, was eine schnelle Integration in Maschinen-HMI\/SCADA-Diagnoseanzeigen ermöglicht.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20DOF322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAusgangskanäle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (Source-Anschluss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNennspannung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (-15% \/ +20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNenn-Ausgangsstrom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,5 A pro Kanal (8 A gesamt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSchaltverzögerung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;300 Mikrosekunden (0 auf 1 \/ 1 auf 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRDS(on)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 Milliohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpitzen-Kurzschlussstrom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetriebstemperatur\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 bis 60 °C (horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSchutzart\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB\u0026amp;R ID-Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0xC0EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industrie-Hardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBenötigt dieses Modul eine externe Freilaufdiode für induktive Lasten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein. Das X20DOF322 verfügt über interne Freilaufdioden, die speziell dafür ausgelegt sind, induktive Energie beim Abschalten abzufangen (typisch 45 VDC). Dies vereinfacht die Verkabelung, da keine zusätzlichen Unterdrückungskomponenten für Standard-Industrierelais oder kleine Spulen erforderlich sind.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie verhält sich der thermische Abschaltschutz bei einem Kurzschluss?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWird ein Kurzschluss oder Überstrom erkannt, schaltet das Modul thermisch ab, um die FET-Stufe zu schützen. Sobald der Fehler behoben und die Modultemperatur stabil ist, versucht das Modul nach einem Zyklus von ca. 10 ms automatisch, den Betrieb wieder aufzunehmen. Ein ständiges Ein- und Ausschalten führt zu dauerhaften Schäden; beheben Sie daher die Ursache des Kurzschlusses umgehend.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelche Bedeutung hat die 10 ms Diagnoseverzögerung?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie 10 ms Diagnoseverzögerung ist ein bewusst eingesetzter Filter für die Ausgangsüberwachung. Sie stellt sicher, dass kurzzeitige Spannungsschwankungen oder kleine Kontaktprellungen keine falschen „Fehler“-Meldungen in den PLC-Diagnoseregistern auslösen, was eine sauberere und zuverlässigere Fehlerprotokollierung ermöglicht.\u003c\/p\u003e\n\u003ch3\u003eInbetriebnahme vor Ort und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eErforderliche Installationskomponenten\u003c\/h3\u003e\n\u003cp\u003eDas X20DOF322 ist ein komponentenbasiertes Modul. Um einen funktionalen I\/O-Knoten zu erstellen, müssen Sie 1x X20TB1F Klemmenblock und 1x X20BM11 Busmodul separat bestellen. Stellen Sie sicher, dass das Busmodul auf einer sauberen, geerdeten Hutschiene montiert wird, um die spezifizierte EMV- und Backplane-Kommunikationsintegrität zu gewährleisten.\u003c\/p\u003e\n\u003ch3\u003eThermische Abminderung und Montage\u003c\/h3\u003e\n\u003cp\u003eDas Modul kann bei horizontaler Montage bis zu 60 °C betrieben werden, bei vertikaler Montage sinkt die zulässige Temperatur auf 50 °C. In Schaltschränken mit hoher Dichte sollte der 12,5 mm Rasterabstand für ausreichende Luftzirkulation sorgen. Wenn der Gesamtstrom nahe an die 8 A-Grenze kommt, empfiehlt sich eine Zwangsbelüftung, um thermische Abminderung oder vorzeitiges Abschalten zu vermeiden.\u003c\/p\u003e\n\u003ch3\u003eErdung und Abschirmung\u003c\/h3\u003e\n\u003cp\u003eTrotz der einfachen 1-Draht-Verbindung ist die Lastseite anfällig für hochfrequente Störungen, wenn sie parallel zu starken Motorstromleitungen verläuft. Halten Sie stets einen Mindestabstand von 200 mm zwischen Ausgangssignalbündeln und Stromleitungen ein. Stellen Sie sicher, dass die Hutschiene direkt mit dem Haupterdungspunkt verbunden ist, um einen niederohmigen Gleichtakt-Rückweg zu gewährleisten.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369251691,"sku":"X20DOF322","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20dof322-byii10gx140.png?v=1776138196"},{"product_id":"b-r-x20do9321-x20-digital-output-module","title":"B\u0026R X20DO9321 X20 Digital-Ausgangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DO9321 (X20DO9321)\u003c\/strong\u003e ist ein Digitalausgangsmodul mit hoher Dichte, entwickelt für die modulare B\u0026amp;R X20 Systemplattform. Es wurde konzipiert, um eine robuste Übertragung von Steuersignalen in industriellen Automatisierungsumgebungen zu ermöglichen – wie beispielsweise Hochgeschwindigkeits-Sortierlinien, automatisierte Montagezellen und komplexe Roboterperipherieschnittstellen. Dieses Modul bietet 12 unabhängige digitale Ausgangskanäle. Es arbeitet mit einem standardmäßigen 24 VDC Logikpegel und einer 1-Draht-Verbindungstopologie und ist für eine platzsparende Steuerungsschrankgestaltung optimiert. Integrierte Status-LEDs für jeden Kanal, den Betriebszustand und die Moduldiagnose ermöglichen eine sofortige visuelle Überprüfung, was Wartungszeiten erheblich verkürzt und die Fehlersuche vor Ort für Automatisierungsingenieure vereinfacht.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieses Ausgangsmodul ist darauf ausgelegt, eine zuverlässige Leistung innerhalb der X20 Backplane-Architektur zu gewährleisten und unterstützt präzises Schalten von Aktoren, Relais und Pilotventilen.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHohe Schaltkanaldichte:\u003c\/strong\u003e Mit 12 unabhängigen Kanälen in einem einzigen Modul bietet das Gerät ein hohes Ausgangs-zu-Platz-Verhältnis, was für Anwendungen mit umfangreicher Steuerkonnektivität in kompakten Gehäusen unerlässlich ist.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1-Draht-Architektur:\u003c\/strong\u003e Nutzt ein schlankes 1-Draht-Verbindungsdesign, das den Kabelaufwand für Ausgänge minimiert und die physische Installation im Schaltschrank vereinfacht.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrierte Diagnostik:\u003c\/strong\u003e Die frontseitige Diagnose-LED-Matrix liefert sofortiges visuelles Feedback zum Status jedes Ausgangskanals, dem aktuellen Betriebszustand des Moduls und der Backplane-Kommunikationsgesundheit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNahtlose Integration:\u003c\/strong\u003e Voll kompatibel mit der B\u0026amp;R X20 Busmodul-Architektur gewährleistet das Gerät eine latenzarme Signalverteilung, die für Echtzeit-Verriegelungssequenzen und Hochgeschwindigkeitsprozesssteuerungen entscheidend ist.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20DO9321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModultyp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigitalausgangsmodul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigitale Ausgänge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Kanäle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNennspannung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVerdrahtungsfähigkeit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-Draht-Verbindung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatusanzeigen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividuelle LEDs für Kanal, Modulzustand und Betriebsstatus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystemkompatibilität\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u0026amp;R X20 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSchutzart\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industrie-Hardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBietet das X20DO9321 einen Kurzschlussschutz für die Ausgänge?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul ist mit integrierten Schutzfunktionen ausgestattet, um die internen Schalttransistoren vor typischen Fehlern zu schützen. Beim Ansteuern induktiver Lasten wie Magnetspulen oder Schützen wird jedoch dringend empfohlen, eine externe Freilaufdiode oder geeignete Unterdrückung einzusetzen, um Hochspannungstransienten zu verhindern, die in das Modul zurückfließen und die Ausgangsstufen beschädigen könnten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann ich das Modul austauschen, ohne die Feldverdrahtung zu stören?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Das B\u0026amp;R X20 System erlaubt das Entfernen und Ersetzen des elektronischen Modulkopfs, während der Basisklemmenblock verdrahtet und auf der DIN-Schiene montiert bleibt. Stellen Sie stets sicher, dass das System spannungsfrei ist oder der sicherheitsrelevante Maschinenzustand erfüllt ist, bevor Sie ein I\/O-Modul im laufenden Betrieb tauschen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas sollte ich prüfen, wenn die LED eines bestimmten Kanals beim Auslösen nicht leuchtet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eÜberprüfen Sie zunächst in der SPS-Anwendung, ob das Ausgangsbit gesetzt wird. Wenn das Bit gesetzt ist, die LED aber ausbleibt, kontrollieren Sie, ob die 24 VDC-Versorgungsschiene für den Ausgangsbereich aktiv ist und die Klemmenverbindung sicher sitzt. Zeigt die Modulstatus-LED einen Fehler an, konsultieren Sie die Diagnoselogs in Ihrem Automation Studio-Projekt für einen spezifischen Hardware-Fehlercode.\u003c\/p\u003e\n\u003ch3\u003eInbetriebnahme vor Ort und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eVerdrahtung und Kabelmanagement\u003c\/h3\u003e\n\u003cp\u003eVerwenden Sie für alle 1-Draht-Verbindungen geeignete Aderendhülsen, um eine sichere Klemmverbindung zu gewährleisten. Aufgrund der 12-Kanal-Dichte organisieren Sie die Ausgangskabel mit Kabelkanälen, um mechanische Belastungen der Klemmenblöcke zu vermeiden. Halten Sie bei der Verdrahtung eine klare Trennung zwischen 24 VDC-Steuerausgängen und höher spannungsführenden Leitungen ein, um induzierte elektrische Störungen auf den Ausgangskanälen zu verhindern.\u003c\/p\u003e\n\u003ch3\u003eDIN-Schienenmontage und Erdung\u003c\/h3\u003e\n\u003cp\u003eDas X20 System nutzt die metallische DIN-Schiene als lokale Erdungsreferenz. Stellen Sie sicher, dass das Modul fest auf einer geerdeten, korrosionsfreien Schiene aufgeschnappt ist. In Umgebungen mit hoher elektromagnetischer Störstrahlung ist diese Erdungsverbindung entscheidend, um Signalstabilität zu gewährleisten und EMI-bedingte Ausgangsfehler zu vermeiden.\u003c\/p\u003e\n\u003ch3\u003eSicherheits- und Verriegelungsprüfung\u003c\/h3\u003e\n\u003cp\u003eBeim Einbinden dieser Ausgänge in sicherheitskritische Steuersequenzen vergewissern Sie sich stets, dass die Ausgänge korrekt auf Ihre Sicherheitslogik abgebildet sind und dass Not-Aus- oder hartverdrahtete Verriegelungen korrekt im Aktorkreis platziert sind. Die Diagnose-LEDs sind ein hervorragendes Werkzeug zur Inbetriebnahme, um die korrekte logische Adressierung vor dem Einschalten der nachgelagerten mechanischen Hardware zu überprüfen.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369317227,"sku":"X20DO9321","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/X20DO9321-3rbsidkohw2.png?v=1776138193"},{"product_id":"b-r-x20ai4632-analog-input-module","title":"B\u0026R X20AI4632 Analog-Eingangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AI4632 (X20AI4632)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein leistungsstarkes Analog-Eingangsmodul, das für das modulare B\u0026amp;R X20 System entwickelt wurde. Dieses Modul verfügt über 4 unabhängige analoge Eingänge mit feldkonfigurierbarer Einstellung für entweder ±10 V Spannungssignale oder 0 bis 20 mA Stromschleifen. Entwickelt für präzisionskritische industrielle Bereiche – einschließlich Hochgeschwindigkeits-Prozesssteuerung, Überwachung der Energieerzeugung und komplexes Roboter-Trajektorien-Feedback – bietet das\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AI4632\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeine schnelle Gesamtkonvertierungszeit von 50 Mikrosekunden über alle Kanäle. Durch die Nutzung der simultanen SAR-(Successive Approximation Register)-Konvertierung und einer 15-Bit-Auflösung gewährleistet das Modul eine präzise, deterministische Signalaufnahme, was es unverzichtbar für Hochgeschwindigkeitsregelkreise macht, die minimale Latenz und hohe Signaltreue erfordern.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieses Modul ist darauf ausgelegt, Präzision in elektrisch anspruchsvollen Umgebungen zu gewährleisten und verfügt über eine robuste differenzielle Eingangsschaltung sowie umfassende Diagnosefunktionen.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignalvielfalt:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eJeder der 4 Kanäle unterstützt entweder Spannung oder Stromsignale, die über die Anschlussklemmen ausgewählt werden können, was Flexibilität für gemischte Sensorsysteme bietet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHochgeschwindigkeitsverarbeitung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMit einer Gesamtkonvertierungszeit von 50 Mikrosekunden und integrierten Tiefpassfiltern dritter Ordnung (10 kHz Grenzfrequenz) balanciert das Modul effektiv hochfrequentes Abtasten mit Rauschunterdrückung.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eErweiterte Diagnostik:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEchtzeitüberwachung erfolgt über LEDs für Modul-Lauf-\/Fehlerstatus und kanalspezifische Funktionen. Die softwaredefinierte Konfiguration ermöglicht eine präzise Steuerung der Eingangsparameter und sorgt für nahtlose Integration in B\u0026amp;R Automation Studio.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrielle Robustheit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDas Modul ist für explosionsgefährdete Bereiche (Klasse I, Division 2) und extreme Umgebungsbedingungen zertifiziert und unterstützt breite Betriebstemperaturen sowie hohe Vibrationsbeständigkeit gemäß DNV- und LR-Standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20AI4632\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEingangskanäle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (differenziell)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignalbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 V oder 0 bis 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAuflösung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 Bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKonvertierungszeit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Mikrosekunden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R ID-Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0x1BA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEingangsimpedanz\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Megaohm (Spannung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGleichtaktunterdrückung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 dB (Gleichstrom und 50 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSchutzart\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZertifizierungen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UKCA, ATEX Zone 2, cULus, cCSAus, DNV, LR, ABS, KC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebstemperatur\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 bis 60 °C (horizontal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industrie-Hardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eKann ich Spannung und Strom auf demselben Modul mischen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Das X20AI4632 ist so ausgelegt, dass beide Signaltypen unterstützt werden. Da der Eingangstyp über die verwendeten Anschlussklemmen bestimmt wird, können einzelne Kanäle je nach Bedarf Ihrer Feldinstrumentierung entweder für ±10 V oder 0 bis 20 mA konfiguriert werden.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas bietet die Funktion „Simultane Eingangskonvertierung“?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie simultane Konvertierung stellt sicher, dass alle 4 Kanäle exakt zum gleichen Zeitpunkt abgetastet werden. Dies ist in Anwendungen wie der Mehrphasen-Leistungsüberwachung oder der koordinierten Bewegungserfassung wichtig, bei denen phasengenaues Datenmaterial erforderlich ist, um aussagekräftige Echtzeitwerte ohne den zeitlichen Versatz zu berechnen, der bei sequentiellen Abtastmodulen auftritt.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenötigt das Modul zusätzliche Komponenten für die Installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Für die vollständige Montage müssen Sie 1x X20TB12 Klemmenblock und 1x X20BM11 Busmodul separat bestellen. Diese Komponenten gewährleisten, dass das Modul den korrekten Rastermaß und die Verbindung innerhalb der X20-Rückplaneinheit beibehält.\u003c\/p\u003e\n\u003ch3\u003eFeldinbetriebnahme und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eErdung und Gleichtakt-Integrität\u003c\/h3\u003e\n\u003cp\u003eDas Modul verfügt über einen Gleichtaktbereich von ±12 V. Stellen Sie sicher, dass Ihre Signalmasse korrekt mit der Systemreferenz verbunden ist, um zu verhindern, dass die Gleichtaktspannung diesen Bereich überschreitet, da dies zu Messungenauigkeiten oder möglichen Schäden an der Eingangsstufe führen kann. Verwenden Sie geschirmte verdrillte Leitungen für alle Eingänge und schließen Sie die Schirme am Schaltschrank-Eintrittspunkt an die Systemmasse an.\u003c\/p\u003e\n\u003ch3\u003eEingangsschutz und Überlastbehandlung\u003c\/h3\u003e\n\u003cp\u003eDas Modul ist gegen versehentliche Verbindung mit Versorgungsspannung geschützt und kann Signalpegel bis ±30 V (Spannungsmodus) oder ±50 mA (Strommodus) aushalten. Trotz dieses Schutzes überprüfen Sie stets die Polung und den Signalbereich Ihrer Verkabelung, bevor Sie die Stromversorgung einschalten. Bei einer Überlast gibt das Modul standardisierte Codes (0x8001 für Unterschreitung, 0x7FFF für Überschreitung) an die Steuerungssoftware aus, was automatisierte Sicherheitslogikreaktionen ermöglicht.\u003c\/p\u003e\n\u003ch3\u003eThermische Abminderung in großer Höhe\u003c\/h3\u003e\n\u003cp\u003eObwohl das Modul für Höhen bis zu 2000 Metern ohne Einschränkungen ausgelegt ist, erfordern Installationen oberhalb dieser Höhe eine aktive thermische Steuerung. Für je 100 Meter über 2000 Meter reduzieren Sie die maximal zulässige Umgebungstemperatur um 0,5 °C, um die geringere Luftdichte und die verminderte Kühlleistung auszugleichen.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369382763,"sku":"X20AI4632","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ai4632-uetexutebvo.png?v=1776138126"},{"product_id":"b-r-x20bc0083-x20-powerlink-bus-controller","title":"B\u0026R X20BC0083 X20 POWERLINK Bus-Controller","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20BC0083 (X20BC0083)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein leistungsstarker Buscontroller, der für die nahtlose Integration von B\u0026amp;R X20 I\/O-Stationen in Echtzeit-POWERLINK-Netzwerke entwickelt wurde. Als gesteuerter Knoten innerhalb industrieller Automatisierungsarchitekturen – wie Hochgeschwindigkeits-Bewegungssteuerungslinien, synchronisierten Mehrachsenrobotern und komplexen Verpackungsmaschinen – ermöglicht dieser Controller einen deterministischen Datenaustausch im Mikrosekundenbereich. Durch die Nutzung eines dualen, geschirmten RJ45-Hub-Designs erlaubt das Modul eine einfache Reihenschaltung von Netzwerksegmenten, wodurch die Verkabelung vereinfacht und gleichzeitig eine robuste Übertragungsrate von 100 Mbit\/s für missionskritische Steuerdaten gewährleistet wird.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieser Buscontroller fungiert als intelligentes Gateway zwischen dem POWERLINK-Master und dem lokalen X20 I\/O-Slice-Rückplane, um eine stabile Kommunikation in anspruchsvollen Umgebungen sicherzustellen.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetzwerksynchronisation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVollständig kompatibel mit den POWERLINK-Protokollen V1 und V2 gewährleistet dieser Typ-2-Controller eine harte Echtzeit-Performance, die eine präzise Korrelation zwischen Netzwerkdatenzyklen und lokaler I\/O-Verarbeitung ermöglicht.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrierte Hub-Funktionalität:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDie duale RJ45-Schnittstelle fungiert als integrierter Hub und unterstützt Standard-Netzwerktopologien mit Segmentlängen bis zu 100 Metern, was ideal für verteilte Schaltschranklayouts ist.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnosegenauigkeit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFrontseitige Status-LEDs bieten sofortiges Feedback zum Modulzustand und Buskommunikationsstatus, wodurch eine schnelle Eingrenzung von Netzwerktopologieproblemen oder knotenspezifischen Fehlern während der Inbetriebnahme möglich ist.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergieeffizienz:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMit einem Busleistungsbedarf von nur 2 W minimiert der Controller die thermische Belastung im Schaltschrank und unterstützt hochdichte Montagekonfigurationen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20BC0083\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModultyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOWERLINK Buscontroller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKnotentyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGesteuerter Knoten (V1\/V2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSchnittstellen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x geschirmte RJ45 (Hub)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eÜbertragungsrate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Segmentlänge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLeistungsaufnahme\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatusanzeigen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModulstatus, Busfunktions-LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystemkompatibilität\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R X20 System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industrie-Hardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist der Vorteil der integrierten Hub-Funktionalität im X20BC0083?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer integrierte Hub ermöglicht die direkte Reihenschaltung von POWERLINK-Stationen ohne externe Netzwerkswitches. Dies reduziert den Verkabelungsaufwand erheblich und vereinfacht die physische Netzwerktopologie, während die für deterministische Steuerungen erforderliche Leistung und Synchronisation erhalten bleiben.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst dieser Buscontroller mit allen X20 I\/O-Modulen kompatibel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer X20BC0083 ist für die Anbindung an das Standard-X20 I\/O-Rückplane ausgelegt. Die Kompatibilität ist in der Regel breit gefächert; stellen Sie jedoch stets sicher, dass Ihre Automation Studio-Projektkonfiguration mit der physischen I\/O-Belegung übereinstimmt und dass Ihre Stromversorgungsmodule korrekt dimensioniert sind, um den Gesamtstromverbrauch der angeschlossenen I\/O-Slices abzudecken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie beeinflusst die Bezeichnung „Typ 2“ die Systemleistung?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Typ-2-Klassifizierung beschreibt spezifische funktionale Fähigkeiten innerhalb der POWERLINK-gesteuerten Knotenarchitektur. Sie gewährleistet volle Kompatibilität mit standardmäßigem zyklischem und azyklischem Datenverkehr und unterstützt komplexe Bewegungsprofile sowie zeitkritische Statusaktualisierungen, die für Hochgeschwindigkeitsfertigungsabläufe erforderlich sind.\u003c\/p\u003e\n\u003ch3\u003eFeldinbetriebnahme und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eNetzwerkverkabelung und Abschirmung\u003c\/h3\u003e\n\u003cp\u003eAufgrund der Übertragungsrate von 100 Mbit\/s verwenden Sie hochwertige Cat5e- oder Cat6-geschirmte Ethernet-Kabel. Schließen Sie die Kabelabschirmungen am Schaltschrank-Eintrittspunkt korrekt mit 360-Grad-Klemmen an, um einen niederohmigen Pfad zum Schutzleiter sicherzustellen. Schlechte Abschirmung in industriellen Umgebungen kann zu intermittierendem Paketverlust oder Netzwerk-\"Jitter\" führen, was sich als Synchronisationsfehler in Ihrer Bewegungssteuerungssequenz äußern kann.\u003c\/p\u003e\n\u003ch3\u003eGrenzen der Reihenschaltungstopologie\u003c\/h3\u003e\n\u003cp\u003eObwohl der Controller die Reihenschaltung über den integrierten Hub unterstützt, sollten Sie die Gesamtanzahl der Knoten und die kumulative Netzwerklänge im Auge behalten. Wird die maximale Segmentlänge von 100 Metern zwischen zwei Stationen überschritten, kommt es zu Signalverschlechterungen und Kommunikationsabbrüchen. Falls Ihr Maschinenlayout längere Strecken erfordert, verwenden Sie einen Industrieswitch oder einen Glasfaserkonverter.\u003c\/p\u003e\n\u003ch3\u003eRückplaneinbau und Diagnose\u003c\/h3\u003e\n\u003cp\u003eBeim Einbau des Controllers in die X20-Busbasis stellen Sie sicher, dass der Verriegelungsmechanismus eingerastet ist und die Pins korrekt ausgerichtet sind. Beobachten Sie beim ersten Einschalten die „Busfunktion“-LED. Ein dauerhaft grüner Status zeigt eine ordnungsgemäße Netzwerksynchronisation an; bei Fehleranzeigen verwenden Sie den Diagnosepuffer von Automation Studio, um die Knotenadresse und Protokollversionseinstellungen mit Ihrem Mastercontroller-Projekt abzugleichen.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369448299,"sku":"X20BC0083","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20bc0083-m3tll3rqras.png?v=1776138139"},{"product_id":"b-r-x20ps9402-x20-power-supply-module","title":"B\u0026R X20PS9402 X20 Stromversorgungsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20PS9402 (X20PS9402)\u003c\/strong\u003e ist ein dediziertes 24 VDC-Netzteilmodul, das für die B\u0026amp;R X20 Systemarchitektur entwickelt wurde. Dieses Modul sorgt für eine stabile Stromversorgung des Buscontrollers, des X2X Link Netzwerks und des angeschlossenen I\/O-Slice-Stacks. Es ist für hochzuverlässige Industrieumgebungen konzipiert – wie Steuerungen von Montagelinien, Förderbandsysteme und verteilte I\/O-Inseln – und gewährleistet eine konstante Betriebsspannung, selbst wenn die Hauptversorgung schwankt. Durch die Konsolidierung des Energiemanagements für die I\/O-Rückwand und den Kommunikationsbus reduziert das \u003cstrong\u003eX20PS9402\u003c\/strong\u003e die Komplexität im Schaltschrank und sichert eine gleichbleibende Signalqualität für hochgeschwindigkeitsautomatisierte Prozesse.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieses Modul ist auf Effizienz und robusten Schutz ausgelegt und dient als Energiegrundlage für lokal angesiedelte X20 I\/O-Stationen.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrierte Stromverteilung:\u003c\/strong\u003e Verwaltet die Stromversorgung für den Buscontroller, X2X Link und die interne I\/O-Elektronik in einem kompakten Modul.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSchutzfunktionen:\u003c\/strong\u003e Ausgestattet mit einer integrierten, nicht austauschbaren Sicherung und Verpolungsschutz, ist das Modul gegen häufige Installationsfehler und transienten Stromausfälle geschützt.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLeistung:\u003c\/strong\u003e Hält eine stabile Ausgangsspannung innerhalb eines Eingangsspannungsbereichs von 24 VDC -15 % \/ +20 % aufrecht und puffert effektiv gegen lokale Spannungseinbrüche oder -spitzen im Werksstromnetz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnosekompatibilität:\u003c\/strong\u003e Für die nahtlose Integration in die X20-Systemdiagnose konzipiert, ermöglicht es dem Mastercontroller, den Versorgungsstatus zu überwachen und Systemabschaltungen durch lokale Stromausfälle zu verhindern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20PS9402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModultyp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC-Netzteilmodul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEingangsspannung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (-15 % \/ +20 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Eingangsstrom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeistungsaufnahme (X2X Link)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,64 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeistungsaufnahme (interne I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSchutz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrierte Sicherung \/ Verpolungsschutz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystemkompatibilität\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u0026amp;R X20 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industriehardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMuss die integrierte Sicherung nach einem Fehler ersetzt werden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein. Die integrierte Sicherung im X20PS9402 ist für automatische Wiederherstellung oder lokalen Schutz ausgelegt und kann nicht ausgetauscht werden. Wenn die Sicherung dauerhaft ausgelöst hat, liegt ein erheblicher interner Fehler oder eine längere Überstromsituation vor, sodass das gesamte Modul ersetzt werden muss, um die Systemsicherheit wiederherzustellen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie ist der Verpolungsschutz umgesetzt?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul verfügt über eine interne Schaltung, die den Stromfluss verhindert, wenn die 24 VDC-Eingangsleitungen verpolt angeschlossen werden. Dies schützt die empfindlichen internen Komponenten und die Rückwandelektronik vor sofortigen Schäden während der Inbetriebnahme.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann ich leistungsstarke Ausgangsmodule direkt von diesem Netzteil versorgen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWährend das X20PS9402 die interne I\/O- und Kommunikationsbusversorgung übernimmt, stellen Sie sicher, dass Ihre Gesamtlast – einschließlich leistungsstarker Ausgangsmodule – das Leistungsbudget Ihrer gesamten X20-Knoten-Konfiguration nicht überschreitet. Verwenden Sie stets den B\u0026amp;R Netzteilrechner für Ihre spezifische Rackbestückung, um eine Lastverteilung sicherzustellen.\u003c\/p\u003e\n\u003ch3\u003eFeldinbetriebnahme und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eEingangsspannungsstabilität\u003c\/h3\u003e\n\u003cp\u003eDas Modul unterstützt einen Eingangsspannungsbereich von 20,4 VDC bis 28,8 VDC. Stellen Sie sicher, dass Ihre Stromversorgung stabilisiert ist und nicht mit stark induktiven Lasten wie großen Schützen oder Motorstartern geteilt wird, da diese Spannungsspitzen verursachen können, die an die obere Grenze der Modulauslegung heranreichen.\u003c\/p\u003e\n\u003ch3\u003eInstallation und Rückwandmontage\u003c\/h3\u003e\n\u003cp\u003eInstallieren Sie das Modul stets auf einer geerdeten DIN-Schiene, um die interne Abschirmung korrekt zu gewährleisten. Beim Aufklicken des Moduls auf die Busbasis achten Sie auf gleichmäßigen, festen Druck. Ist das Modul locker, können die Stromkontakte hohen Widerstand aufweisen, was zu intermittierenden Spannungseinbrüchen oder unerwarteten Systemneustarts führen kann.\u003c\/p\u003e\n\u003ch3\u003eKabelanschluss\u003c\/h3\u003e\n\u003cp\u003eVerwenden Sie für alle 24 VDC-Eingangsleitungen geeignete Aderendhülsen. Aufgrund des Stromverbrauchs von 0,7 A sind übliche Leiterquerschnitte (z. B. 0,75 mm² oder 1,0 mm²) in der Regel ausreichend, sofern sie für die Umgebung geeignet sind. Ziehen Sie die Anschlussklemmschrauben mit dem vom Hersteller vorgegebenen Drehmoment an, um eine Überhitzung der Kontakte im Betrieb zu vermeiden.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369579371,"sku":"X20PS9402","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ps9402-1wo2wwwplbs.png?v=1776138217"},{"product_id":"b-r-x20dm9324-x20-digital-mixed-input-output-module","title":"B\u0026R X20DM9324 X20 Digitales Misch-Eingangs-\/Ausgangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DM9324 (X20DM9324)\u003c\/strong\u003e ist ein vielseitiges digitales Mixed-I\/O-Modul, das für die modulare B\u0026amp;R X20 Systemplattform entwickelt wurde. Für kompakte Schaltschrankumgebungen konzipiert, integriert diese Einheit 8 digitale Eingangskanäle und 4 digitale Ausgangskanäle in einem einzigen Modul und bietet so eine effiziente Bauform für Maschinen, die eine dichte I\/O-Anbindung benötigen. Ideal für verteilte Steuerungsaufgaben in Verpackungsanlagen, Montageplatzlogik und Hochgeschwindigkeits-Materialhandling, verfügt das Modul über konfigurierbare Eingangsfilter zur Unterdrückung von Kontaktprellen und elektromagnetischen Störungen. Die 24 VDC Sink-Eingänge und 500 mA Source-Ausgänge gewährleisten die Kompatibilität mit einer breiten Palette standardisierter industrieller Sensoren und Aktoren.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieses Modul vereint hochdichte Signalverarbeitung mit robustem elektrischem Schutz und ermöglicht eine vereinfachte Verdrahtung über 1-Draht-Verbindungstopologien.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMixed-Signal-Architektur:\u003c\/strong\u003e Kombiniert 8 sinking digitale Eingänge (24 VDC) und 4 sourcing digitale Ausgänge (24 VDC, 500 mA) in einem Gehäuse und optimiert so die I\/O-Anzahl pro Steckplatz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignalqualität:\u003c\/strong\u003e Jeder Eingangskanal verfügt über konfigurierbare Filter, die eine zuverlässige Signalaufnahme sicherstellen und vorübergehende Störungen oder mechanisches Prellen, wie es in industriellen Umgebungen üblich ist, effektiv ignorieren.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVereinfachte Verdrahtung:\u003c\/strong\u003e Das 1-Draht-Verbindungsdesign reduziert das Kabelvolumen im Schaltschrank, erleichtert die Kabelführung und Wartung in beengten Räumen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eErweiterter Temperaturbereich:\u003c\/strong\u003e Für anspruchsvolle Umgebungen ausgelegt, unterstützt das Modul einen weiten Betriebstemperaturbereich von -25 °C bis 60 °C und gewährleistet so eine konstante Leistung sowohl bei Kaltstart als auch bei hohen Temperaturen im Schaltschrank.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20DM9324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20 Serie Digital Mixed I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigitale Eingänge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 x 24 VDC (Sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigitale Ausgänge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 24 VDC (Source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAusgangskapazität\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA pro Kanal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVerdrahtungslogik\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-Draht-Verbindung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilterkonfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKonfigurierbare Eingangsfilter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetriebstemperatur\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 bis 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLagerungstemperatur\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 bis 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSchutzart\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMontage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteckbar (X20 Rückwand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industriehardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWie beeinflussen die konfigurierbaren Eingangsfilter die Reaktionszeit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie konfigurierbaren Filter führen eine wählbare Verzögerung bei den digitalen Eingängen ein. Während niedrigere Filtereinstellungen schnellere Reaktionszeiten für Hochgeschwindigkeitssignale bieten, ermöglichen höhere Einstellungen eine bessere Störunterdrückung. Stimmen Sie während der Inbetriebnahme die Filtereinstellung auf die spezifische Signalfrequenz Ihres Sensors ab, um eine Balance zwischen Reaktionsgeschwindigkeit und Signalqualität zu erreichen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKönnen die 500 mA Ausgänge induktive Lasten wie Magnetventile ansteuern?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, die 500 mA Source-Ausgänge sind für Standard-Industrielasten ausgelegt. Beim Ansteuern induktiver Komponenten wie Magnetspulen oder Relais ist jedoch stets sicherzustellen, dass eine externe Freilaufdiode oder Unterdrückungseinrichtung verwendet wird, um Hochspannungsspitzen zu vermeiden, die die Ausgangstransistoren beschädigen könnten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist der Vorteil einer 1-Draht-Verbindung in diesem Modul?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie 1-Draht-Architektur reduziert erheblich die Menge an Verkabelung, die für den Signalrückweg zum Modul erforderlich ist, da das gemeinsame Potential über die Busbasis geführt wird. Dies vereinfacht das Schaltschrankdesign und beschleunigt die physische Installation der Feldgeräte.\u003c\/p\u003e\n\u003ch3\u003eFeldinbetriebnahme und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eThermisches Management in Gehäusen\u003c\/h3\u003e\n\u003cp\u003eObwohl das Modul bis zu 60 °C zuverlässig arbeitet, kann sich bei gestapelten Modulen mit hohen Ausgangsströmen lokal Wärme ansammeln. Stellen Sie sicher, dass der Gesamtstrom im Rack die thermische Kapazität des Netzteils nicht überschreitet. Verwenden Sie bei hoher Last eine Zwangsbelüftung im Schaltschrank, wenn die Innentemperatur sich der oberen Grenze nähert.\u003c\/p\u003e\n\u003ch3\u003eKurzschluss- und Überlastschutz\u003c\/h3\u003e\n\u003cp\u003eDie digitalen Ausgänge sind für Standard-Industrielasten ausgelegt. Im Falle eines dauerhaften Kurzschlusses an einem Ausgang löst der interne Schutz des Moduls aus, um dauerhafte Schäden an der Hardware zu verhindern. Beheben Sie stets die physikalische Störung (z. B. beschädigte Kabel oder defekte Magnetventile), bevor Sie den Betrieb in Ihrer SPS-Software wieder aufnehmen.\u003c\/p\u003e\n\u003ch3\u003ePotentialausgleich und EMI-Unterdrückung\u003c\/h3\u003e\n\u003cp\u003eMontieren Sie das X20DM9324 auf einer ordnungsgemäß geerdeten metallischen DIN-Schiene, um eine effektive EMI-Unterdrückung durch die interne Abschirmung des Moduls zu gewährleisten. Halten Sie Signalkabel mindestens 200 mm von Hochstrom-Leitungen getrennt, um Übersprechen zu minimieren, insbesondere beim Auslesen von Niedrigstrom-Sensorsignalen über die 1-Draht-Konfiguration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369775979,"sku":"X20DM9324","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20dm9324-sglcsbjojup.png?v=1776138184"},{"product_id":"b-r-x20bc0063-x20-profibus-dp-bus-controller","title":"B\u0026R X20BC0063 X20 PROFIBUS DP Bus-Controller","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20BC0063 (X20BC0063)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein leistungsstarker Buscontroller, der entwickelt wurde, um das modulare B\u0026amp;R X20 System in bestehende PROFIBUS DP Feldbusnetzwerke zu integrieren. Als Gateway zwischen dem X20 I\/O-Rückplane und dem Master-Steuerungsnetzwerk ermöglicht dieser Controller eine nahtlose Kommunikation in komplexen Automatisierungsumgebungen – wie beispielsweise in Automobilproduktionslinien, schweren Materialflusssystemen und groß angelegten Prozessanlagen. Durch die Bereitstellung einer standardisierten 9-poligen DSUB-Schnittstelle gewährleistet der\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20BC0063\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeine zuverlässige, deterministische Datenübertragung, die es Ingenieuren erlaubt, die Interoperabilität zwischen B\u0026amp;R-Hardware und heterogenen industriellen Steuerungsarchitekturen aufrechtzuerhalten.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieses Modul fungiert als Kommunikationskopf für eine X20 I\/O-Station und verwaltet den zyklischen Datentransfer zwischen dem PROFIBUS-Master und den verteilten I\/O-Slices.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePROFIBUS-Konnektivität:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerfügt über einen standardmäßigen 9-poligen DSUB-Stecker für die einfache Integration in bestehende PROFIBUS DP-Architekturen und unterstützt eine schnelle Feldbuskommunikation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAls Teil des X20-Ökosystems bietet es eine kompakte, skalierbare Schnittstelle. Beachten Sie, dass das System eine eigenständige Busbasis, ein dediziertes Netzteilmodul und einen kompatiblen Klemmenblock benötigt, um den I\/O-Knoten vollständig zusammenzustellen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnoseübersicht:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAusgestattet mit einer integrierten LED-Anzeige, die den Echtzeitstatus der Modulgesundheit, der aktuellen Busfunktion und der aktiven Datenübertragungszyklen anzeigt, was schnelle Felddiagnosen und reduzierte Ausfallzeiten ermöglicht.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergieeffizienz:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimiert für einen niedrigen Energieverbrauch mit maximal 2,3 W, wodurch die thermische Belastung im Schaltschrank minimiert und eine hohe Dichte an I\/O-Konfigurationen ermöglicht wird.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20BC0063\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModultyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuscontroller (PROFIBUS DP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSchnittstelle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x PROFIBUS DP (9-poliger DSUB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLeistungsaufnahme\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,3 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatusanzeigen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModulstatus, Busfunktion, Datenübertragungs-LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystemkompatibilität\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R X20 System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industriehardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIst der erforderliche Klemmenblock für die I\/O-Montage im Lieferumfang des X20BC0063 enthalten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein. Dieses Gerät ist nur der Controller-Kopf. Für eine vollständige Installation müssen Sie die kompatible X20 Busbasis, das passende X20 Netzteilmodul und die erforderlichen Klemmenblöcke separat bestellen, abhängig von Ihren spezifischen I\/O-Dichteanforderungen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie signalisiert das Modul einen Kommunikationsverlust im PROFIBUS-Netzwerk?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie LED „Busfunktion“ zeigt den Status sofort visuell an. Wenn die PROFIBUS-Verbindung unterbrochen ist oder der Controller die Kommunikation mit dem PROFIBUS-Master verliert, ändert sich dieser Indikator. Detaillierte Fehlercodes und Diagnoseregister können über die Master-Controller-Software abgerufen werden, um den spezifischen Busfehler zu identifizieren.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie viele I\/O-Module kann dieser Controller maximal verwalten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer X20BC0063 verwaltet die Gesamtanzahl der I\/O-Slices, die innerhalb der spezifischen X20 Busbasis-Beschränkungen erlaubt sind. Stellen Sie sicher, dass die Gesamtleistungsaufnahme der angeschlossenen I\/O-Module die Kapazität Ihres gewählten Netzteilmoduls nicht überschreitet.\u003c\/p\u003e\n\u003ch3\u003eInbetriebnahme vor Ort und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003ePROFIBUS-Abschlussprotokolle\u003c\/h3\u003e\n\u003cp\u003eBeim Anschluss des PROFIBUS DP-Kabels an den 9-poligen DSUB-Stecker muss sichergestellt werden, dass das Netzwerk an beiden physischen Enden des Bussegments korrekt terminiert ist. Eine fehlerhafte Terminierung verursacht Signalreflexionen, die zu zyklischen Kommunikationsfehlern und erhöhten „Kollisionen“ oder „Datenübertragungs“-Fehlerraten in den Diagnoseprotokollen führen.\u003c\/p\u003e\n\u003ch3\u003eAbschirmung und Erdung\u003c\/h3\u003e\n\u003cp\u003eDie Abschirmung des PROFIBUS-Kabels muss korrekt mit dem Metallgehäuse des DSUB-Steckers verbunden sein. Stellen Sie sicher, dass die DIN-Schiene im Schaltschrank sauber und fest mit der Haupterdung verbunden ist, um einen niederohmigen Pfad für den EMI-Schutz zu gewährleisten, was besonders in Umgebungen mit erheblicher elektrischer Störstrahlung wichtig ist.\u003c\/p\u003e\n\u003ch3\u003eBusbasis- und Stromversorgungsaufbau\u003c\/h3\u003e\n\u003cp\u003eBeim Zusammenbau der Station müssen alle X20-Module fest auf der Busbasis eingerastet sein, um die Rückplane-Kommunikation sicherzustellen. Überprüfen Sie, dass das Netzteilmodul korrekt relativ zum Controller positioniert ist, um Engpässe bei der Stromversorgung zu vermeiden. Nach der Montage führen Sie eine Sichtprüfung der Klemmenblöcke durch, um sicherzustellen, dass keine Pins während der Installation verbogen wurden.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369841515,"sku":"X20BC0063","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20bc0063-bfguwn2mxve.png?v=1776138138"},{"product_id":"b-r-x20mk0203-x20-safekey-memory-module","title":"B\u0026R X20MK0203 X20 SafeKEY Speichermodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20MK0203 (X20MK0203)\u003c\/strong\u003e ist ein dediziertes SafeKEY-Speichermodul, das speziell für die B\u0026amp;R X20SL80xx-Serie von Sicherheitscontrollern entwickelt wurde. Mit 8 MB sicherem Anwendungsspeicher fungiert dieses Bauteil als wichtiges Sicherheits- und Konfigurationstoken für sicherheitskritische Automatisierungssysteme. Es gewährleistet die Integrität des sicherheitsrelevanten Anwendungscodes und ermöglicht eine schnelle Inbetriebnahme der Maschine oder den Austausch von Sicherheits-CPUs durch nahtlose Übertragung von Projektdaten und Sicherheitskonfigurationen. Das Modul ist für industrielle Langlebigkeit ausgelegt und garantiert 100.000 Lösch-\/Schreibzyklen, wodurch es häufige Updates und den langfristigen Einsatz in hochzuverlässigen Umgebungen wie automatisierten Fertigungszellen und sicherheitsinstrumentierten Prozessanlagen unterstützt.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieses Modul bietet eine sichere, zuverlässige Speicher-Schnittstelle, die direkt in die X20-Sicherheitscontroller-Architektur integriert ist.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnwendungssicherheit:\u003c\/strong\u003e Das SafeKEY ist unerlässlich für hardwaregebundene Sicherheitsprojekte und stellt sicher, dass nur autorisierter Anwendungscode auf der Zielhardware X20SL80xx ausgeführt wird.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpeicherzuverlässigkeit:\u003c\/strong\u003e Das 8 MB Flash-Speichermodul ist für intensive Nutzung ausgelegt und unterstützt bis zu 100.000 Schreib-\/Löschvorgänge, wodurch ein robuster Puffer für Protokollierung und wiederholte Anwendungsprogrammierung bereitgestellt wird.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontageflexibilität:\u003c\/strong\u003e Das Gerät ist für den Betrieb in horizontaler und vertikaler Einbaulage ausgelegt, was eine flexible Integration in kompakte, sicherheitsbewertete Steuergehäuse ermöglicht.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUmweltbeständigkeit:\u003c\/strong\u003e Mit Schutzart IP20 ist das Modul für Standard-Elektroschaltschrankumgebungen konzipiert. Es unterstützt Installationshöhen bis zu 2000 Metern ohne Leistungsreduzierung; darüber hinaus ist eine Absenkung der Umgebungstemperatur um 0,5 °C pro 100 Meter erforderlich, um die thermische Stabilität zu gewährleisten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20MK0203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModultyp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20 SafeKEY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKompatibilität\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20SL80xx Serie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeichergröße\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSchreib-\/Löschzyklen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100.000 garantiert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSchutzart\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMontage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal und Vertikal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHöhenbegrenzung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m (Leistungsreduzierung darüber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industriehardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas passiert, wenn das X20MK0203 SafeKEY während des Systembetriebs entfernt wird?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas SafeKEY enthält das anwendungsspezifische Sicherheitsprogramm und die Konfiguration. Wird es während des laufenden Betriebs entfernt, führt dies in der Regel zu einem sicherheitsbedingten Stopp oder einem CPU-Fehler, da der Controller keinen Zugriff mehr auf den vorgeschriebenen Sicherheitsanwendungscode hat. Schalten Sie das System immer aus, bevor Sie den Schlüssel ein- oder ausstecken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWorin unterscheidet sich dieses Modul von einer Standard-CompactFlash-Karte?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas X20MK0203 ist eine spezialisierte Sicherheitskomponente, die hardwarekompatibel mit den Sicherheitsfunktionen der X20SL80xx-Serie ist. Es ist kryptografisch an das Sicherheitsprojekt gebunden, wodurch das Sicherheitsintegritätsniveau (SIL) des Controllers erhalten bleibt und der Code nicht durch unautorisierte Standard-Speichergeräte verändert werden kann.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst es möglich, den Inhalt eines X20MK0203 auf ein anderes zur Sicherung zu kopieren?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie B\u0026amp;R-Sicherheitsarchitektur erzwingt strenge Versions- und Integritätsprüfungen. Projektsicherungen sollten über die B\u0026amp;R Automation Studio Softwareumgebung durchgeführt werden. Ein direktes binäres Klonen des SafeKEY ist eingeschränkt, um die unautorisierte Verbreitung sicherheitskritischer Maschinenlogik zu verhindern.\u003c\/p\u003e\n\u003ch3\u003eFeldinbetriebnahme und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eInstallation und Handhabung\u003c\/h3\u003e\n\u003cp\u003eStellen Sie sicher, dass das System vollständig spannungsfrei ist, bevor Sie das X20MK0203 in den vorgesehenen Steckplatz des Sicherheitscontrollers einsetzen. Fassen Sie das Modul nur an den Kanten an, um elektrostatische Entladungen (ESD) zu vermeiden, die den internen Flash-Speicher beschädigen und intermittierende CRC-Fehler beim Laden der Anwendung verursachen können.\u003c\/p\u003e\n\u003ch3\u003eThermische Überlegungen in großen Höhen\u003c\/h3\u003e\n\u003cp\u003eWenn Ihr Installationsort über 2000 Meter liegt (z. B. in abgelegenen Bergbau- oder Fertigungsanlagen in den Bergen), stellen Sie sicher, dass die Innentemperatur des Schaltschrankes aktiv geregelt wird. Für je 100 Meter über 2000 Meter senken Sie die maximal zulässige Umgebungstemperatur im Schrank um 0,5 °C, um den reduzierten konvektiven Kühleffekt der dünneren Luft auszugleichen.\u003c\/p\u003e\n\u003ch3\u003eÜberprüfung der Sicherheitsintegrität\u003c\/h3\u003e\n\u003cp\u003eNach der Erstinstallation und dem Laden des Sicherheitsprojekts führen Sie eine vollständige Prüfsummenüberprüfung mit der X20-Sicherheitssoftwarediagnose durch. Stellen Sie sicher, dass das System ohne speicherbezogene Alarme in den „Run“-Zustand übergeht. Ein anhaltender Speicherfehler während des Bootvorgangs weist auf einen möglichen Hardwarefehler des Schlüssels hin, der umgehend ersetzt werden muss, um das Sicherheitsniveau der Maschine zu gewährleisten.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086369939819,"sku":"X20MK0203","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20mk0203-5tiwschnthy.png?v=1776138213"},{"product_id":"b-r-x20ai4222-x20-analog-input-module","title":"B\u0026R X20AI4222 X20 Analoges Eingangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AI4222 (X20AI4222)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein hochpräzises Analog-Eingangsmodul, das für die modulare B\u0026amp;R X20 Systemplattform entwickelt wurde. Als wichtige Schnittstelle für die industrielle Prozesssteuerung erfasst dieses Modul fein abgestufte Spannungsdaten von Feldsensoren in anspruchsvollen Anwendungen wie Drucküberwachung, Ventilpositionierung und Hochgeschwindigkeits-Rückkopplungsschleifen bei Spritzgießmaschinen oder chemischen Mischprozessen. Mit 4 unabhängigen Kanälen und einer 12-Bit-Digitalwandlerauflösung gewährleistet das Modul eine genaue Digitalisierung von ±10 V Signalen. Seine Hochgeschwindigkeits-Umwandlungsfähigkeit von 400 Mikrosekunden für alle Eingänge macht es zur idealen Lösung für Echtzeitanwendungen, bei denen die Determiniertheit der Regelkreise erforderlich ist, um Prozessabweichungen oder mechanische Schwingungen zu verhindern.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieses Modul verwendet eine differenzielle Eingangsschaltung, die für die Aufrechterhaltung der Signalqualität in elektrisch störungsanfälligen Industrieumgebungen unerlässlich ist.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDifferenzielle Signalverarbeitung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDurch die Messung der Spannungsdifferenz zwischen zwei Leitungen unterdrückt das Modul inhärent Gleichtaktstörungen und reduziert so erheblich die Auswirkungen elektromagnetischer Interferenzen (EMI), die von nahegelegenen Frequenzumrichtern oder starken Schützen erzeugt werden.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHochgeschwindigkeits-Umwandlung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDer integrierte Verarbeitungskern erreicht eine Gesamtumwandlungszeit von 400 Mikrosekunden für den gesamten Kanalumfang, wodurch die SPS eine schnell reagierende Steuerlogik ausführen kann, die auf subtile Prozessänderungen reagiert.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnosefunktionen:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMit einer umfassenden LED-Matrix bietet das Modul Echtzeit-Statusanzeigen für kanalspezifische Funktionen, den Gesamtbetriebszustand und die Modulgesundheit. Der B\u0026amp;R ID-Code 0xCAB1 gewährleistet sofortige Erkennung und Konfigurationskompatibilität innerhalb der Automation Studio Umgebung.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20AI4222\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModultyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog-Eingangsmodul\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEingangskanäle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (differenziell)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignalbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAuflösung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±12 Bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUmwandlungszeit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 Mikrosekunden (gesamt)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R ID-Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0xCAB1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatusanzeigen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLEDs für Kanalfunktion, Zustand und Modulgesundheit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystemkompatibilität\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R X20 System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industriehardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWarum wird für dieses Modul eine differenzielle Eingangsschaltung bevorzugt?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBei Standard-Einzelendeingängen kann Rauschen auf der Signalreferenz Messfehler verursachen. Differenzielle Eingänge messen das Potenzial zwischen zwei Leitungen und gleichen so elektromagnetische Störungen aus, die entlang des Kabelwegs aufgenommen werden. Dies ist besonders wichtig bei der Verbindung von Sensoren über lange Strecken oder in der Nähe von leistungsstarken Industrieanlagen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie profitiert meine Anwendung von der 400-Mikrosekunden-Umwandlungszeit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn schnelllebigen Bewegungssteuerungen oder bei der Hochgeschwindigkeitsprozess-Synchronisation ist Latenz ein kritischer Faktor. Eine Umwandlungszeit von 400 Mikrosekunden stellt sicher, dass die von der SPS verarbeiteten Daten nahezu in Echtzeit vorliegen, sodass der Controller Korrekturanpassungen sofort vornehmen kann – entscheidend für die präzise Aufrechterhaltung von Druck- oder Durchflussstabilität.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas soll ich tun, wenn die Status-LED des Moduls einen Fehler anzeigt?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eÜberprüfen Sie zunächst, ob die 24 VDC-Versorgung des Modulbusses innerhalb der Toleranzen liegt. Verwenden Sie anschließend das Diagnosewerkzeug von B\u0026amp;R Automation Studio, um ID-Code-Abweichungen oder spezifische Kanalf ehler zu prüfen. Stellen Sie sicher, dass der Anschlussblock korrekt sitzt und kein Eingang den ±10 V Bereich überschreitet, da Überspannungen den internen Schutz auslösen können.\u003c\/p\u003e\n\u003ch3\u003eInbetriebnahme vor Ort und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eAbschirmung und Kabelführung\u003c\/h3\u003e\n\u003cp\u003eUm die Integrität des ±10 V Signals zu gewährleisten, verwenden Sie hochwertige, verdrillte und geschirmte Kabel. Erdung der Kabelabschirmung erfolgt am Sensorende und, wenn möglich, sollte die Abschirmung am X20-System-Erdungsschienenanschluss im Schaltschrank angebunden werden. Halten Sie analoge Signalleitungen physisch von Hochspannungskabeln mindestens 200 mm entfernt, um die Induktion von Oberschwingungsstörungen zu vermeiden.\u003c\/p\u003e\n\u003ch3\u003eRichtige Montage des Anschlussblocks\u003c\/h3\u003e\n\u003cp\u003eDas X20-System setzt eine feste physische und elektrische Verbindung zwischen Busmodul und Elektronikmodul voraus. Beim Einbau des X20AI4222 stellen Sie sicher, dass es fest in die Basis einrastet. Ist das Modul nicht richtig montiert, kann die Backplane-Kommunikation unterbrochen werden, was zu „Modulstatus“-Fehlern in Ihrer Software führt.\u003c\/p\u003e\n\u003ch3\u003eKalibrierung und Bereichsprüfung\u003c\/h3\u003e\n\u003cp\u003eFühren Sie vor der Inbetriebnahme eine Schleifenprüfung für jeden Kanal mit einem kalibrierten Signalgenerator durch. Verifizieren Sie, dass die in Ihrer Software angezeigten Werte den Eingangsspannungen über den gesamten Bereich (–10 V bis +10 V) entsprechen. Zeigt ein Kanal eine konstante Abweichung, überprüfen Sie die Verkabelung auf Erdschleifen oder Spannungsabfälle im Rückleiter.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370038123,"sku":"X20AI4222","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ai4222-a44vf3y0gha.png?v=1776138122"},{"product_id":"b-r-x20cp1586-x20-atom-processor-module","title":"B\u0026R X20CP1586 X20 ATOM Prozessormodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP1586 (X20CP1586)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein leistungsstarker kompakter Controller, der für die modulare B\u0026amp;R X20 Systemplattform entwickelt wurde. Er dient als zentrale Intelligenzknoten in komplexen Automatisierungsarchitekturen – einschließlich Verpackungsmaschinen, Mehrachsenrobotik und hochgeschwindigkeits-synchronisierten Fertigungslinien. Diese auf ATOM basierende CPU bietet die erforderliche Rechendichte für anspruchsvolle Echtzeitsteuerungsaufgaben. Durch die Konsolidierung leistungsstarker Verarbeitungskapazitäten in einem schlanken Formfaktor ermöglicht das Modul Ingenieuren, eine hohe Durchsatzrate in Steuerungsschränken zu gewährleisten, in denen der Platz begrenzt ist. Die Einheit bewältigt effektiv komplexe Bewegungsprofile, Hochgeschwindigkeits-Feldbuskommunikation (POWERLINK) und intensive logische Datenverarbeitung, was die Zykluszeiten erheblich verkürzt und Engpässe in automatisierten Produktionsumgebungen eliminiert.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDiese CPU nutzt eine energieeffiziente Intel ATOM-Architektur, um eine hohe Befehlsausführung pro Takt zu liefern, ohne die thermische Belastung, die mit herkömmlichen Industrie-PCs verbunden ist.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProzessorarchitektur:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasierend auf der robusten ATOM-Plattform unterstützt der Controller komplexe mathematische Operationen und Multithread-Logikausführung, die für Echtzeit-Bewegungssteuerung und Synchronisation unerlässlich sind.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDas Modul ist direkt mit dem X20-Rückplane verbunden und bietet Hochgeschwindigkeitszugriff auf eine Vielzahl von I\/O-Modulen, Kommunikations-Slices und spezialisierten Technologiemodulen innerhalb des X20-Ökosystems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKommunikationsschnittstelle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimiert für die nativen industriellen Protokolle von B\u0026amp;R fungiert diese CPU als Master-Knoten für die Hochgeschwindigkeits-Netzwerksynchronisation und gewährleistet Mikrosekunden-genaue Genauigkeit über verteilte Maschineneinheiten hinweg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKompakte Bauform:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMit den Maßen 8,5 cm x 15 cm x 9,9 cm ist das Gerät für eine hochdichte Montage optimiert und ermöglicht skalierbares Systemwachstum innerhalb modularer Maschinenrahmen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20CP1586\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModultyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 CPU ATOM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProzessorplattform\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntel ATOM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAbmessungen (L x W x H)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8,5 cm x 15 cm x 9,9 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNettogewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystemkompatibilität\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R X20 System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebslogik\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEchtzeit-PLC und Bewegungssteuerung\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industrie-Hardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIst der X20CP1586 in der Lage, Bewegungssteuerungsaufgaben ohne zusätzlichen Controller zu bewältigen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Diese CPU ist speziell dafür ausgelegt, sowohl hochrangige Maschinenlogik als auch synchronisierte Bewegungssteuerungsalgorithmen auszuführen. Sie fungiert als Master-Controller für B\u0026amp;R-Antriebsplattformen und verwaltet Trajektorienplanung, Interpolation und Achssynchronisation nativ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelche Kühlstrategie wird für diese ATOM-CPU empfohlen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul ist für natürliche Konvektionskühlung innerhalb eines Standard-Steuerschranks ausgelegt. Um die langfristige Zuverlässigkeit des Prozessors zu gewährleisten, sollte oberhalb und unterhalb des Moduls mindestens 50 mm Freiraum für die Luftzirkulation eingehalten werden, und die Umgebungstemperatur im Schrank darf die angegebenen Betriebsgrenzen nicht überschreiten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie verwaltet diese CPU das Feldbus-Netzwerkmanagement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer X20CP1586 verfügt über integrierte Unterstützung für POWERLINK und andere Standard-Feldbusprotokolle von B\u0026amp;R. Er steuert den Echtzeit-Kommunikationsstack und stellt sicher, dass der zyklische Datenaustausch zwischen Controller und entfernten I\/O- oder Antriebseinheiten deterministisch und jitterfrei bleibt.\u003c\/p\u003e\n\u003ch3\u003eInbetriebnahme vor Ort und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eFirmware- und Projektmanagement\u003c\/h3\u003e\n\u003cp\u003eVor dem ersten Einschalten stellen Sie sicher, dass die CompactFlash-Karte oder der interne Speicher die korrekte Projektkonfiguration enthält, die aus Automation Studio exportiert wurde. Verwenden Sie den dedizierten Schnittstellenport für die Erstprogrammierung und Diagnose. Sichern Sie das Maschinenprojekt immer auf einem externen Laufwerk, bevor Sie Firmware-Updates durchführen.\u003c\/p\u003e\n\u003ch3\u003eStromversorgung und Störungsisolation\u003c\/h3\u003e\n\u003cp\u003eDie CPU benötigt eine stabile 24 VDC-Stromversorgung. Verwenden Sie eine separate Stromschiene für Logikkomponenten und halten Sie diese elektrisch von leistungsstarken induktiven Lasten wie Motor-Schützen und Frequenzumrichtern isoliert. Diese Isolation verhindert, dass elektrische Störungen CPU-Neustarts oder Kommunikationsfehler auf dem X20-Rückplane verursachen.\u003c\/p\u003e\n\u003ch3\u003eMontage und Umweltbedingungen\u003c\/h3\u003e\n\u003cp\u003eBefestigen Sie die CPU auf einer starren, geerdeten DIN-Schiene, um die Übertragung mechanischer Vibrationen zu minimieren. In Umgebungen mit hoher Vibration stellen Sie sicher, dass das Modul fest in der Busmodul-Basis verriegelt ist. Halten Sie die Einheit von korrosiven Umgebungen fern und sorgen Sie dafür, dass der Schrank eine Schutzart von z. B. IP54 oder höher aufweist, um Staub- und Kondensatbildung auf den internen Kühlrippen zu verhindern.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370300267,"sku":"X20CP1586","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20cp1586-hsptdnz0nfy.png?v=1776138167"},{"product_id":"b-r-x20di6371-x20-digital-input-module","title":"B\u0026R X20DI6371 X20 Digital-Eingangsmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DI6371 (X20DI6371)\u003c\/strong\u003e ist ein hochdichtes Digital-Eingangsmodul, das in die modulare B\u0026amp;R X20 Systemarchitektur integriert ist. Es wurde für eine zuverlässige Signalerfassung in industriellen Automatisierungsumgebungen entwickelt – wie z. B. Steuerungen von Montagelinien, Förderbandverfolgungssysteme und verteilte I\/O-Inseln in Fertigungszellen. Dieses Modul bietet 6 unabhängige digitale Eingangskanäle. Es arbeitet mit einem standardmäßigen 24 VDC-Logikpegel und unterstützt flexible 1- oder 2-Draht-Anschlusstopologien, was eine vereinfachte Verdrahtung in platzbeschränkten Schaltschrankumgebungen ermöglicht. Das Modul verfügt über integrierte Status-LEDs für jeden Kanal, den Betriebszustand und die Modulgesundheitsdiagnose, was eine schnelle Fehlerbehebung vor Ort und reduzierte Wartungszeiten gewährleistet.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDieses Modul ist für robuste Signaltrennung und konsistente Leistung innerhalb des X20 Rückplanes ausgelegt. Es verarbeitet hochgeschaltete digitale Signale und liefert präzises Statusfeedback für die PLC-Logikausführung.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignalflexibilität:\u003c\/strong\u003e Jeder der 6 digitalen Eingänge ist mit 1- oder 2-Draht-Verdrahtungskonfigurationen kompatibel, was eine vielseitige Sensorintegration für verschiedene Feldanforderungen ermöglicht.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrierte Diagnostik:\u003c\/strong\u003e Die frontseitige Diagnose-LED-Matrix bietet eine sofortige visuelle Überprüfung der I\/O-Funktion pro Kanal, des aktuellen Betriebszustands des Moduls und des allgemeinen Kommunikationsstatus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Vollständig kompatibel mit dem B\u0026amp;R X20 Rückplane gewährleistet das Modul eine latenzarme Signalübertragung, die für die Echtzeit-Prozessüberwachung und Verriegelungssequenzen bei schweren Maschinen und automatisierten Produktionslinien entscheidend ist.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20DI6371\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModultyp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigitales Eingangsmodul\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigitale Eingänge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Kanäle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNennspannung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVerdrahtungsfähigkeit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1- oder 2-Draht-Anschlüsse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatusanzeigen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividuelle LEDs für Kanal, Modulzustand und Betriebsstatus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystemkompatibilität\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u0026amp;R X20 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetriebstemperatur\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 bis 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industriehardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eUnterstützt das X20DI6371 sowohl sourcing- als auch sinking-Sensorsignale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul ist für den Betrieb innerhalb der standardmäßigen X20 Eingangsarchitektur ausgelegt. Es ist wichtig sicherzustellen, dass Ihre Feldsensoren so konfiguriert sind, dass sie den Eingangsspannungspegeln (24 VDC) entsprechen, die für die B\u0026amp;R X20 Eingangs-Module spezifiziert sind, um Signalfehlinterpretationen oder mögliche Schäden an der Eingangsstufe zu vermeiden.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann ich das X20DI6371 austauschen, ohne die Feldverdrahtung zu trennen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, das B\u0026amp;R X20 System verwendet ein modulares Design, bei dem der Klemmenblock (das „Busmodul“) auf der DIN-Schiene verdrahtet bleibt. Sie können den Verriegelungsmechanismus lösen, um den elektronischen Modulkopf für einen schnellen Austausch während der Wartung zu entfernen, vorausgesetzt, die Stromversorgung wird gemäß den Sicherheitsvorschriften abgeschaltet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas bedeuten die Statusanzeigen, wenn eine Kanal-LED flackert?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEine flackernde LED weist typischerweise auf ein instabiles Signal oder ein Kontaktprellen beim angeschlossenen Feldgerät hin. Wenn die LED einen Modulfehler anzeigt, vergleichen Sie die Diagnose-Register in Ihrer B\u0026amp;R Automation Studio Software, um spezifische I\/O-Kanalfehler zu identifizieren.\u003c\/p\u003e\n\u003ch3\u003eFeldinbetriebnahme und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eVerdrahtungs- und Anschlussintegrität\u003c\/h3\u003e\n\u003cp\u003eBeim Anschließen von 2-Draht-Sensoren stellen Sie sicher, dass die Potenzialversorgung und die Signalleitungen ordnungsgemäß abgeschirmt sind, wenn die Kabellänge 10 Meter überschreitet. Verwenden Sie Aderendhülsen an allen Litzenenden, um Kurzschlüsse durch einzelne Litzen an den Klemmenpunkten zu vermeiden.\u003c\/p\u003e\n\u003ch3\u003eDIN-Schienenmontage und Erdung\u003c\/h3\u003e\n\u003cp\u003eInstallieren Sie das Modul stets auf einer geerdeten metallischen DIN-Schiene. Das X20 Modul nutzt den Schienenkontakt, um eine lokale Erdungsreferenz herzustellen, die entscheidend ist, um EMI\/RFI-Störungen in Umgebungen mit Frequenzumrichtern oder Hochvolt-Schützen zu unterdrücken. Stellen Sie sicher, dass die Oberfläche der DIN-Schiene am Kontaktpunkt frei von Farbe oder Oxidation ist.\u003c\/p\u003e\n\u003ch3\u003eDiagnoseüberwachung\u003c\/h3\u003e\n\u003cp\u003eNutzen Sie die integrierten LED-Anzeigen als primäre Referenz während der ersten Inbetriebnahme, um die physikalischen I\/O mit Ihrer PLC-Anwendung abzugleichen. Wenn ein Kanal trotz eines nachgewiesenen 24 VDC-Signals an der Klemme inaktiv bleibt, prüfen Sie die ordnungsgemäße Erdung des gemeinsamen Rückleiters, bevor Sie das Modul auf interne Hardwarefehler untersuchen.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370365803,"sku":"X20DI6371","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20di6371-wnlfa0xzcj3.png?v=1776138183"},{"product_id":"b-r-x20cp1583-x20-system-master-controller-cpu-module","title":"B\u0026R X20CP1583 X20 System Master Controller CPU-Modul","description":"\u003ch3\u003eVerarbeitungsleistung und Rolle in der Industrieautomation\u003c\/h3\u003e\n\u003cp\u003eDer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP1583 (X20CP1583)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein leistungsstarker industrieller Embedded-Controller, der als zentrales Verarbeitungselement für komplexe B\u0026amp;R X20-Automatisierungsarchitekturen konzipiert wurde. Speziell ausgelegt für anspruchsvolle Prozessregelkreise, hochpräzise Mehrachsen-Bewegungssynchronisation und Echtzeit-Datenerfassung in Bereichen wie Automobilmontage, petrochemische Verarbeitung und Überwachung erneuerbarer Energien, bewältigt diese CPU gleichzeitig mehrere Rechenaufgaben mit hoher Determiniertheit. Das lüfterlose Kühldesign eliminiert mechanische Ausfallrisiken und verhindert Ausfallzeiten durch das Eindringen von Partikeln aus der Luft. Die Integration dieses robusten Controllers in Ihren zentralen Schaltschrank schafft eine hochverfügbare Automatisierungstopologie, die zyklische Ausführungsstörungen minimiert, eine latenzarme Netzwerkscannung garantiert und Produktionsprozesse vor ungeplanten Systemstillständen schützt.\u003c\/p\u003e\n\u003ch3\u003eNetzwerkarchitektur und Hardwarediagnose\u003c\/h3\u003e\n\u003cp\u003eMit dem offiziellen B\u0026amp;R-ID-Code 0xD45B ausgestattet, wird dieser Master-Controller von einem hocheffizienten Prozessor mit 333 MHz Taktfrequenz angetrieben. Die Hardware bietet eine umfangreiche Kommunikationsmatrix mit einem RS232-Seriellinterface für ältere Feldgeräte, einem Standard-Ethernet-Port für die Integration ins Unternehmensnetzwerk, zwei USB-Anschlüssen für lokale Systemdiagnosen sowie einem integrierten X2X-Link-Masterbus zur Steuerung lokaler I\/O-Erweiterungen. Die Echtzeitsynchronisation entfernter Antriebe und verteilter I\/O-Blöcke erfolgt über eine onboard Echtzeit-Ethernet POWERLINK (V1\/V2)-Verbindung. Der Systemzustand wird kontinuierlich über eine integrierte LED-Anzeige überwacht, die Feldtechnikern sofortige visuelle Informationen zu CPU-Funktion, Übertemperaturzuständen, Ethernet-Verbindungen, POWERLINK-Schleifen, CompactFlash-Kartenzugriff und internen Backup-Batterieständen liefert.\u003c\/p\u003e\n\u003ch3\u003eUmfassende Leistungsspezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSystemparameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Werte\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20CP1583\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System CPU Modul\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R ID-Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0xD45B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProzessor-Taktfrequenz\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e333 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrierte Schnittstellen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x RS232, 1x Ethernet, 1x POWERLINK V1\/V2, 2x USB, 1x X2X Link\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLeistungsaufnahme\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8,2 W (Grundlast ohne Schnittstellenmodul und USB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKühlprofil\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLüfterlose Konvektionskühlung\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpeichersubsystem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrierter CompactFlash-Slot für Systemsoftware und Anwendungsabbilder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnoseinfrastruktur\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLokale LEDs für CPU-, Temperatur-, Ethernet-, POWERLINK-, CF- und Batteriestatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebliche Luftfeuchtigkeitsgrenzen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBruttoversandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,5 kg (eingeschlossen in mehrschichtiger elektrostatischer Abschirmung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ zur industriellen Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist zu prüfen, wenn die lokale Übertemperatur-LED aktiviert wird?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEine aktive Übertemperaturanzeige bedeutet, dass der interne CPU-Siliziumchip seine konstruktiven Temperaturgrenzen überschritten hat. Überprüfen Sie sofort das Gehäuse, um sicherzustellen, dass die Lüftungsgitter nicht blockiert sind, kontrollieren Sie, dass die lüfterlosen Konvektionskühlrippen am CPU-Gehäuse frei von Staub sind, und vergewissern Sie sich, dass benachbarte wärmeerzeugende Geräte die Abstandsanforderungen einhalten.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie verwaltet diese CPU Programm-Backups und die Ausführung des Betriebssystems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer X20CP1583 verwendet eine industrielle CompactFlash-Karte als primäres nichtflüchtiges Bootmedium. Das B\u0026amp;R Automation Runtime Betriebssystem, Hardwarekonfigurationen und der kompilierte Anwendungscode sind vollständig auf dieser Karte gespeichert. Diese Architektur ermöglicht einen sofortigen Hardwareaustausch durch Kartentausch, ohne dass ein separates Feldprogrammiergerät erforderlich ist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann sich die Basis-Leistungsaufnahme von 8,2 W je nach Hardwarekonfiguration ändern?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Die Angabe von 8,2 W beschreibt die Grundlast des Prozessors und der Kern-Backplane-Logikleitungen. Das Hinzufügen von Kommunikationsschnittstellenmodulen in den Zusatzsteckplätzen oder der Anschluss von stromintensiven Felddiagnosegeräten an die USB-Ports erhöht den Gesamtleistungsbedarf, der bei der Planung der zentralen 24 VDC-Stromversorgung berücksichtigt werden muss.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eRichtlinien für Inbetriebnahme und Einsatz vor Ort\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHandhabungsprotokolle für CompactFlash-Speicher:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDie CompactFlash-Karten-Schnittstelle ist empfindlich gegenüber elektrostatischer Entladung (ESD) und Dateien können bei unsachgemäßer Handhabung beschädigt werden. Trennen Sie stets die Hauptstromversorgung von 24 VDC von der CPU, bevor Sie die Speicherkarte einlegen oder entfernen. Stellen Sie sicher, dass die Karte über B\u0026amp;R Automation Studio partitioniert und formatiert ist, um eine korrekte Bootsequenz zu gewährleisten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOWERLINK-Kabelabschirmung und Erdungsstandards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHochgeschwindigkeits-Echtzeit-POWERLINK-Kommunikation ist anfällig für hochfrequente elektromagnetische Störungen (EMI), die von benachbarten frequenzgeregelten Antrieben (VFDs) erzeugt werden. Verwenden Sie unbedingt industrielle Ethernet-Kabel der Kategorie 5e (oder höher) mit doppelter Abschirmung. Erden Sie die geflochtene Kupferabschirmung vollständig über niederohmige Erdungsklemmen am Gehäuseeingangspunkt an der metallischen DIN-Schiene.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanische Schienenmontageausrichtung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMontieren Sie das CPU-Modul vertikal auf sauberen, korrosionsfreien Standard-DIN-Schienen. Vergewissern Sie sich, dass die integrierten Backplane-Erdungsklemmen eine feste Metall-auf-Metall-Verbindung mit der geerdeten Montageplatte herstellen, um einen absoluten Schutzleiterpfad für das gesamte angeschlossene X20 I\/O-Modulsegment zu gewährleisten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370398571,"sku":"X20CP1583","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20cp1583-0mfa3kdgcve.png?v=1776138163"},{"product_id":"b-r-x20bt9100-x20-system-x2x-link-bus-transmitter-module","title":"B\u0026R X20BT9100 X20 System X2X Link Bus-Sendemodul","description":"\u003ch3\u003eTechnische Beschreibung und Rolle der Netzwerkerweiterung\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20BT9100 (X20BT9100)\u003c\/strong\u003e ist ein industrielles Bus-Sendemodul, das für die hochdichte B\u0026amp;R X20 Systemplattform entwickelt wurde. Dieses Modul fungiert als Hochgeschwindigkeits-Datenrepeater und Strominjektor, speziell konzipiert, um die physikalischen Grenzen des lokalen X2X Link Backplane-Busses über verteilte Automatisierungsanordnungen hinweg zu erweitern – wie sie beispielsweise in mehrstufigen Automobilmontagelinien, kommunalen Wasserverteilungsanlagen und großen Verpackungsmaschinenlinien vorkommen. Wenn die physikalische Länge oder der kumulative Stromverbrauch eines lokalen I\/O-Knotens die Standardgrenzen des Hauptcontrollers überschreitet, fängt das Modul den Datenstrom ab, verstärkt die Kommunikationssignale und injiziert frische Hilfsenergie, um die interne Elektronik der nachfolgenden I\/O-Segmente zu versorgen. Die Integration dieses Sendemoduls in Ihre Schrankarchitektur gewährleistet eine synchrone Datenübertragung über separate Steuerschränke hinweg, erhält die Signalqualität über lange Distanzen und verhindert unerwartete Busausfälle, die Prozessstillstände verursachen.\u003c\/p\u003e\n\u003ch3\u003eBetriebsarchitektur und Stromverteilung\u003c\/h3\u003e\n\u003cp\u003eDieses Systemmodul wird direkt an die Standard-X20-Backplane angeschlossen und fungiert als Gateway, das lokale Kommunikationsleitungen in einen erweiterten X2X Link-Segment überführt. Über seine Datenrepeater-Funktion hinaus verfügt die Hardware über integrierte Stromerzeugungsschaltungen, die stabilisierte Niederspannungslogikversorgung direkt an die internen Buskomponenten benachbarter Module liefern. Für den Dauerbetrieb in hochstöranfälligen Umgebungen ausgelegt, beinhaltet das Modul eine umfassende galvanische Trennung zwischen der internen Busstruktur und der eingehenden Versorgungsleitung, um die empfindliche CPU-Logik vor Spannungsspitzen auf der Feldseite zu schützen. Die Echtzeit-Diagnoseüberwachung erfolgt über eine integrierte LED-Anzeige, die Feldtechnikern eine sofortige und klare Verifikation von drei kritischen Parametern bietet: aktive X2X-Busfunktion, lokaler Betriebsstatus und allgemeiner Modulzustand.\u003c\/p\u003e\n\u003ch3\u003eTechnische Leistungsdaten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eBetriebsparameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20BT9100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Bus-Sendemodul\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus-Schnittstellentyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX2X Link Bus Master\/Erweiterung\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrierte Funktionalität\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignalrepeater plus interne I\/O-Bus-Stromversorgung\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElektrische Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJa (Bus zur Versorgungsleitung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnoseinfrastruktur\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLokale LED-Überwachung für Bus-, Lauf- und Modulstatus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKühlprofil\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Konvektionskühlung im Standard-Rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebsfeuchtigkeitsbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLagerungstemperaturbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 bis 55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetto-Gerätegewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCa. 0,11 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrutto-Versandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,5 kg (eingeschlossen in mehrlagigem elektrostatischem Schutz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystemintegrations-FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWann genau ist es notwendig, ein X20BT9100 Sendemodul in ein X20 I\/O-Rack einzufügen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEin X20BT9100 muss unter zwei Hauptbedingungen installiert werden: Erstens, wenn die physikalische Entfernung zwischen benachbarten I\/O-Blöcken eine verlängerte Kabelführung erfordert, die Standard-Backplanes nicht unterstützen können; zweitens, wenn der Gesamtstromverbrauch der internen Modul-Logikplatinen die Leistungsabgabe des Haupt-CPU- oder Stromversorgungsmoduls überschreitet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eErfordert dieses Modul separate Konfigurationsschritte innerhalb von B\u0026amp;R Automation Studio?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul muss an der exakten Position in der physischen Hardware-Baumstruktur eingefügt werden, die es auf der DIN-Schiene einnimmt. Automation Studio erkennt automatisch seine Rolle als Segment-Stromversorgungsgrenze und passt die Berechnung des Leistungsbudgets für die nachfolgenden Module entsprechend an.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann das X20BT9100 im laufenden Betrieb der Hauptmaschinen-Netzwerks hot-swap-fähig ausgetauscht werden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, vorausgesetzt, die zugrundeliegende Klemmenbasis ist für Hot-Swap-Betrieb ausgelegt. Das Herausnehmen dieses Moduls unterbricht jedoch sowohl die Datenleitung als auch die Logikstromversorgung aller nachfolgenden I\/O-Segmente weiter unten in der Linie, wodurch diese spezifischen abhängigen Kanäle sofort in sichere Zustände wechseln.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInbetriebnahme vor Ort und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAbschirmung und Erdung der Bussegmentkabel:\u003c\/strong\u003e Verlängerte X2X Link-Leitungen übertragen hochfrequente Datenpakete und sind anfällig für elektromagnetische Störungen (EMI). Es muss zertifiziertes B\u0026amp;R geschirmtes verdrilltes Kommunikationskabel verwendet werden. Die Geflechtschirmung des Kabels ist am Gehäuseeingang fest mit der Erdungsschiene oder der metallischen DIN-Schiene zu verbinden, um induktive Störgeräusche zu verhindern, die die Datensynchronisation beeinträchtigen könnten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eÜberprüfung des Strombudgets:\u003c\/strong\u003e Vor der Erstinbetriebnahme sind die kumulativen Stromverbrauchswerte aller Module rechts vom X20BT9100 in Ihrem Engineering-Layout zu prüfen. Stellen Sie sicher, dass die Gesamtanforderung die maximale Leistungsabgabe des Moduls nicht überschreitet, um Überstromauslösungen während des Systemstarts zu vermeiden.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanische Ausrichtung und Einsetzen:\u003c\/strong\u003e Schieben Sie das Modul vertikal in die passende X20-Klemmenbasis. Üben Sie gleichmäßigen Druck aus, bis sowohl die oberen als auch die unteren Kunststoffhalteklammern mit einem deutlichen Klick einrasten. Eine fehlerhafte Montage kann zu unregelmäßigem Kontaktwiderstand an den Backplane-Pins führen, was intermittierende Busfehler und Kommunikationsstörungen verursacht.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370496875,"sku":"X20BT9100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20bt9100-0xqgv5335q2.png?v=1776138154"},{"product_id":"b-r-x20ap3131-x20-system-3-phase-energy-metering-module","title":"B\u0026R X20AP3131 X20 System 3-Phasen Energie-Messmodul","description":"\u003ch3\u003eProduktübersicht\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20AP3131 (X20AP3131)\u003c\/strong\u003e ist ein industrietaugliches dreiphasiges Energiemessmodul, das für die modulare B\u0026amp;R X20 Systemplattform entwickelt wurde. Es wurde konzipiert, um Echtzeit-Leistungsanalysen in energieintensiven Industriebereichen wie Automobilwerken, Papierfabriken, Rechenzentren und Schwerindustrieanlagen bereitzustellen. Dieses fortschrittliche Modul misst und verarbeitet Hauptstromverteilungsnetze bis zu 480 VAC bei 50\/60 Hz. Durch die Ausführung von Hochgeschwindigkeits-Mathematikalgorithmen an Bord berechnet die Hardware direkt Wirkleistung (effektive Leistung), Blindleistung und Scheinleistung sowie Energiekennwerte und echte Effektivwerte (RMS). Die Integration dieses spezialisierten Moduls in Ihr Automatisierungsnetz optimiert die Transparenz bei der Unterabrechnung, unterstützt Energiespitzenmanagement und erkennt Phasenasymmetrien, bevor sie nachgelagerte Mehrachsenantriebe beschädigen.\u003c\/p\u003e\n\u003ch3\u003eTechnische Konfiguration\u003c\/h3\u003e\n\u003cp\u003eDiese Messeinheit verfügt über ein spezielles Gehäuse mit 240 V Kodierung, das ein versehentliches mechanisches Einstecken in Niederspannungssensoranschlüsse verhindert und den lokalen I\/O-Knoten vor schweren Überspannungsschäden schützt. Das Modul bietet 3 Hochvolt-Analogeingänge zur direkten Erfassung der Phasenspannungen sowie 4 präzise Analogeingänge, die für 5 A AC-Stromwandler-Sekundärkreise ausgelegt sind.\u003c\/p\u003e\n\u003cp\u003eEin zentrales Leistungsmerkmal des Moduls ist die Integration der B\u0026amp;R NetTime Mikrosekunden-Synchronisationsfunktion. Dieser verteilte Taktmechanismus versieht die Leistungsdaten mit hochpräzisen Zeitstempeln im Systemnetzwerk, sodass Ingenieure Spannungseinbrüche oder Stromspitzen direkt mit bestimmten mechanischen Achsenbewegungen auf entfernten Antrieben korrelieren können. Der vierte Stromkanal ist speziell für die Messung des Neutralleiters vorgesehen, um eine umfassende Vektorberechnung von Unwuchtzuständen in nichtlinearen industriellen Lastumgebungen zu gewährleisten.\u003c\/p\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribut\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20AP3131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX20 System Leistung und Energiemessung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpannungskanäle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Analogeingänge (Phase-zu-Neutral \/ Phase-zu-Phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNennspannung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBis zu 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStromkanäle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analogeingänge (3 Phasen + 1 Neutralleiter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNennstrom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A AC (geeignet für externe Stromwandler)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetzfrequenz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBerechnungen an Bord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWirk-, Blind-, Scheinleistung; RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronisation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrierte NetTime Netzwerk-Zeitstempelung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware-Kodierung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 V mechanische Kodierung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetriebsfeuchtigkeit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 bis 95 % nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eÖsterreich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHäufig gestellte Fragen zur Industriehardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWarum verfügt das Modul über vier Stromeingänge, obwohl eine Standard-Dreiphasenstromleitung überwacht wird?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie ersten drei Stromeingänge sind direkt den Phasen L1, L2 und L3 zugeordnet. Der vierte Hilfseingang ist für die Überwachung des Neutralleiters (N) ausgelegt. In Industrieanlagen mit starken einphasigen Schaltnetzteilen oder nichtlinearen Lasten ist die Erfassung des Neutralstroms unerlässlich, um Oberschwingungsverzerrungen und Erdschlussströme zu erkennen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKönnen die Hochspannungsleitungen bis zu 480 VAC direkt an den Standard-X20-Klemmenblock angeschlossen werden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, allerdings muss sichergestellt werden, dass der korrekte, offiziell vorgesehene 240 V kodierte Klemmenblock verwendet wird, der zur Architektur des X20AP3131 passt. Die mechanische Kodierung verhindert, dass Hochspannungsanschlüsse in Standard-24-VDC-Digital- oder Analog-I\/O-Steckplätze eingesteckt werden können.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelchen konkreten Nutzen bietet die NetTime-Funktion für die Energiemessung?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNetTime synchronisiert die internen ADCs des Moduls mit der Systemuhr des zentralen Controllers bis auf Mikrosekundenebene. Dadurch kann der Master-Controller Energiespitzen exakt mit Positionen in einer Hochgeschwindigkeits-Bewegungssteuerungssequenz abgleichen, was die genaue Identifikation von energieintensiven mechanischen Vorgängen oder Antriebsachsen erleichtert.\u003c\/p\u003e\n\u003ch3\u003eInbetriebnahme- und Sicherheitsrichtlinien\u003c\/h3\u003e\n\u003ch3\u003eProtokolle zur Stromwandlerverriegelung (CT)\u003c\/h3\u003e\n\u003cp\u003eBeim Anschluss der Stromeingänge ist sicherzustellen, dass die externen Stromwandler für einen Sekundärausgang von 5 A AC ausgelegt sind. Der Sekundärkreis eines aktiven Stromwandlers darf niemals geöffnet werden, solange die Primär-Hochspannungsleitung unter Spannung steht; dies würde extrem hohe Lichtbögen an den CT-Anschlüssen erzeugen, die Ausrüstung zerstören und schwere Stromschläge verursachen.\u003c\/p\u003e\n\u003ch3\u003ePhasenausrichtung und Spannungsanschlussrotation\u003c\/h3\u003e\n\u003cp\u003eDie Anschlüsse der Spannungserfassung (L1, L2, L3) müssen sorgfältig mit den entsprechenden Stromwandlerkreisen abgestimmt werden. Eine falsche Phasenzuordnung (z. B. L1-Spannung mit L2-Stromwandler) verfälscht die interne Vektorrechnung und führt zu fehlerhaften Berechnungen des Wirkleistungsfaktors.\u003c\/p\u003e\n\u003ch3\u003eErde und Störunterdrückungsstandards\u003c\/h3\u003e\n\u003cp\u003eDas Modul ist auf einer sauberen, korrosionsfreien Hutschiene zu montieren, die direkt mit der Haupterdung des Schaltschrankes verbunden ist. Hochspannungsversorgungsleitungen sind von Niederspannungs-Kommunikationsbackplanes im Kabelmanagementsystem fernzuhalten, um elektromagnetische Kopplungen und Messrauschen in den 16-Bit-Analogverarbeitungsstufen zu vermeiden.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370562411,"sku":"X20AP3131","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ap3131-dj32iz1jjzv.png?v=1776138130"},{"product_id":"b-r-x20ai1744-x20-system-analog-input-module","title":"B\u0026R X20AI1744 X20 System Analog-Eingangsmodul","description":"\u003ch3\u003eTechnische Beschreibung und Anwendung\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20AI1744 (X20AI1744)\u003c\/strong\u003e ist ein analoges Eingangsmodul in Industriequalität, entwickelt für die hochdichte B\u0026amp;R X20 System-Automatisierungsplattform. Es wurde konzipiert, um stabile, hochauflösende Signalüberwachung in anspruchsvollen Prozessumgebungen zu gewährleisten – wie Ölraffinerien, automatisierte chemische Mischanlagen und Hochgeschwindigkeitsfertigungslinien. Dieses Modul ist mit standardmäßigen industriellen analogen Feldsensoren kompatibel. Es verarbeitet kontinuierliche physikalische Größen (einschließlich Druck, Durchflussraten, Füllstandsmessungen und mechanische Positionierung) präzise und wandelt sie in deterministische digitale Datenströme für die Haupt-CPU um. Der Einsatz dieses Moduls in Ihrer dezentralen I\/O-Matrix optimiert die Präzision der Regelkreise, minimiert Signalverzögerungen und schützt die Kernsystemlogik vor unerwarteten Spannungsschwankungen auf der Feldseite.\u003c\/p\u003e\n\u003ch3\u003eBetriebsarchitektur und Schnittstellenlogik\u003c\/h3\u003e\n\u003cp\u003eDiese I\/O-Komponente verfügt über eine fortschrittliche Analog-Digital-Wandlungsschaltung, die eine präzise Signalwiedergabe über alle aktiven Kanäle sicherstellt. Mit individuell über Software einstellbaren Kanalfilterparametern eliminiert das Modul hochfrequentes elektrisches Rauschen, das durch benachbarte Frequenzumrichter (VFDs) und starke induktive Schaltgeräte erzeugt wird. Die interne Elektronik benötigt nur eine minimale Leistungsaufnahme vom zugrundeliegenden X20 Backplane-Bus, wodurch die thermische Effizienz im gesamten lokalen Knotenstapel erhalten bleibt. Die Hardware beinhaltet eine Echtzeit-Diagnoseüberwachung, die es der Einheit ermöglicht, kontinuierlich Signalgrenzwerte zu prüfen und offene Schaltkreise oder Überbereichszustände direkt an die zentrale Prozessarchitektur zu melden.\u003c\/p\u003e\n\u003ch3\u003eTechnische Leistungsdaten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eBetriebsparameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20AI1744\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Analog-Eingang\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal-Eingangstyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKontinuierliche analoge Signale (Spannung\/Strom)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D-Wandlungsauflösung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHochpräzise industrielle Auflösung\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnosefunktionen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKanal-spezifische Fehlerüberwachung via Bus-Software\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolationsbarriere\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptokoppler-Isolation zwischen Bus und I\/O-Kanälen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatusanzeige\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrierte LED-Betriebsanzeigen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebsfeuchtigkeitsbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLagerungstemperaturbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 bis 55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNettogewicht des Geräts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCa. 0,10 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBruttoversandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,0 kg (verpackt in mehrlagiger Schutzverpackung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystemintegrations-FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWie meldet das X20AI1744 einen Sensorleitungsfehler oder ein Signal außerhalb des zulässigen Bereichs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWenn ein Feldsensorkreis einen Drahtbruch hat oder unter die Standard-Grenzwerte fällt (z. B. unter 3,6 mA bei einem 4-20 mA-Kreis), setzt das Modul ein Diagnose-Fehlerbit im internen Statusbyte. Diese Daten werden über den X20-Bus an B\u0026amp;R Automation Studio übertragen, sodass programmierte Alarme sofort ausgelöst werden können.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses analoge Eingangsmodul gleichzeitig Spannungs- und Stromsignale verarbeiten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie spezifischen Kanal-Konfigurationen, einschließlich elektrischer Signalbereiche und Skalierungsfaktoren, werden im Hardwarebaum von B\u0026amp;R Automation Studio eingestellt. Stellen Sie sicher, dass Ihre Eingangssignaltypen mit den für jeden einzelnen Anschluss definierten Parametern übereinstimmen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIst eine externe Abschirmung für die analogen Eingangssensorleitungen erforderlich?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Analoge Signale arbeiten auf niedrigem Pegel und sind anfällig für elektromagnetische Störungen (EMI). Verwenden Sie daher verdrillte, geschirmte Instrumentierungskabel und erden Sie die Abschirmung ordnungsgemäß am Gehäuseeingang, um die Genauigkeit zu gewährleisten.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFeldinbetriebnahme- und Installationsprotokolle\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAbschirmungsanschluss und Rauschunterdrückung:\u003c\/strong\u003e Um Erdschleifen zu vermeiden, die die analoge Genauigkeit verfälschen, verbinden Sie die Kabelschirmung nur an einem einzigen Punkt mit dem Funktionserdeanschluss, vorzugsweise an der geerdeten DIN-Schiene des I\/O-Gehäuses. Halten Sie ungeschirmte Drahtabschnitte beim Einführen in die Klemmenblöcke so kurz wie möglich.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModulmontage und Halteausrichtung:\u003c\/strong\u003e Montieren Sie das X20AI1744 vertikal in die dafür vorgesehene X20-Steckbasis. Drücken Sie es fest, bis die oberen und unteren Kunststoffverriegelungen mit einem deutlichen Klick einrasten, was bestätigt, dass die internen Backplane-Pins eine niederohmige Verbindung zum Systembus hergestellt haben.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermisches Management des Gehäuses:\u003c\/strong\u003e Obwohl das Modul einen niedrigen Stromverbrauch hat, erfordert die enge Anordnung mehrerer analoger Einheiten in einem geschlossenen Gehäuse eine ausreichende Konvektionsbelüftung. Halten Sie die üblichen Freiräume ober- und unterhalb der X20-Schiene ein, um sicherzustellen, dass die Umgebungsbedingungen innerhalb sicherer Betriebsgrenzen bleiben.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370627947,"sku":"X20AI1744","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ai1744-bt1nmunhzjy.png?v=1776138119"},{"product_id":"b-r-at4222-x20-system-temperature-sensor-input-module","title":"B\u0026R AT4222 X20 System Temperatursensor-Eingangsmodul","description":"\u003ch3\u003eTechnische Beschreibung und Rolle der Temperaturüberwachung\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eAT4222 (AT4222)\u003c\/strong\u003e ist ein industrielles Temperatursensor-Eingangsmodul, das für die modulare B\u0026amp;R X20 System-Automatisierungsplattform entwickelt wurde. Es wurde entwickelt, um eine stabile, hochpräzise Temperaturüberwachung in anspruchsvollen Verarbeitungsumgebungen zu gewährleisten – wie beispielsweise bei Kunststoff-Extrusionsmaschinen, Pasteurisierungskreisläufen in der Lebensmittel- und Getränkeindustrie, chemischen Reaktoren und industriellen Trocknungsöfen. Dieses Modul verarbeitet Mikrovolt- oder Widerstandsänderungen von feldmontierten Temperatursensoren und wandelt die rohen analogen Sensoreingänge in deterministische digitale Datenströme für die Hauptsteuerung um. Durch den Einsatz spezieller onboard Filter- und Rauschunterdrückungsschaltungen eliminiert das Modul Messschwankungen, die durch benachbarte Hochleistungs-Heizelemente oder Frequenzumrichter (VFDs) verursacht werden, verhindert thermisches Durchgehen und schützt kritische Produktionsanlagen vor ungeplanten Betriebsausfällen.\u003c\/p\u003e\n\u003ch3\u003eDiagnosematrix und Hardware-Architektur\u003c\/h3\u003e\n\u003cp\u003eMit dem offiziellen B\u0026amp;R ID-Code 0x1BA7 verfügt dieses Temperatur-Interface-Modul über eine zweischichtige Diagnosearchitektur, die physische LED-Hardwareanzeigen mit softwarezugänglichen Datenregistern kombiniert. Techniker können den Systemzustand sofort über lokal angebrachte LEDs überprüfen, die den aktuellen Betriebszustand des Moduls, die Ein-\/Ausgabefunktionen der einzelnen Kanäle sowie Laufzeitfehler anzeigen. Für eine optimale Leistungsbalance innerhalb des I\/O-Schienenstapels zieht das Modul nur 0,01 W von den Backplane-Bus-Logikleitungen und maximal 1,1 W vom internen I\/O-Stromschienen. Das Gehäuse entspricht der Schutzart IP20 und gewährleistet bei korrektem Einsetzen in den entsprechenden Anschlussblock einen berührungssicheren Schutz.\u003c\/p\u003e\n\u003ch3\u003eBetriebsleistungs-Spezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSystemparameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAT4222\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Temperaturmessung\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R ID-Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0x1BA7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSchutzart\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus-Stromaufnahme\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,01 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterne I\/O-Stromversorgung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,1 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware-Diagnose\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED-Anzeigen für Modulstatus, Laufzeit\/Fehler und Eingänge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware-Diagnose\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterne Kanalstatus-Bytes über Automation Studio\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebsfeuchtigkeitsgrenzen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLagerungstemperaturbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 bis 55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBruttoversandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,5 kg (eingeschlossen in elektrostatischer Entladungsschutzverpackung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ für den Feldeinsatz\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWie meldet das AT4222 einen offenen Stromkreis oder einen defekten Sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWenn ein Sensorsignal im Feldkabel unterbrochen oder mechanisch beschädigt wird, steigt der Kanalwiderstand über den maximalen Eingangsschwellenwert an. Die interne Logik erkennt diesen Zustand sofort, meldet einen spezifischen Fehlercode an die übergeordnete CPU über den Systembus und aktiviert die rote Fehler-LED des Kanals, um eine schnelle Fehlerbehebung zu ermöglichen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses Modul im laufenden Betrieb des restlichen X20-Racks ausgetauscht werden (Hot-Swap)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa, sofern die zugrundeliegende X20-Terminalbasis Hot-Swapping unterstützt. Sie können das aktive Modul entnehmen und einsetzen, ohne die Stromversorgung des gesamten I\/O-Segments auszuschalten. Allerdings registriert die Anwendungssoftware für diese spezifischen Kanäle einen I\/O-Kommunikationsfehlercode, bis das neue Modul initialisiert ist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelche praktische Auswirkung hat die Schutzart IP20 auf die Installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Schutzart IP20 bedeutet Schutz gegen feste Fremdkörper größer als 12,5 mm (z. B. Finger), bietet jedoch keinen Schutz gegen das Eindringen von Flüssigkeiten oder leitfähigem Staub in der Luft. Daher muss dieses Modul stets in einem geschlossenen Industriegehäuse mit mindestens IP54-Schutz installiert werden.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInbetriebnahme und Verdrahtungsprotokolle im Feld\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignalabschirmung und Leitungsführung:\u003c\/strong\u003e Temperatursensorsignale arbeiten mit äußerst niedrigen Spannungs- oder Widerstandswerten und sind sehr anfällig für elektromagnetische Störungen (EMI). Verwenden Sie für alle Sensorleitungen verdrillte, abgeschirmte Instrumentierungskabel und führen Sie diese Leitungen in separaten Niederspannungskabelkanälen, die mindestens 30 cm Abstand zu Hochspannungs-Wechselstrommotorleitungen haben.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnschlusswiderstand und Kompensationskontrolle:\u003c\/strong\u003e Stellen Sie sicher, dass alle abisolierten Sensorleiterenden sauber und frei von Oxidation sind, bevor Sie sie in den Anschlussblock klemmen. Lose Verbindungen erhöhen den unerwünschten Punktwiderstand im Messkreis, was zu einer dauerhaft positiven Temperaturabweichung und einer Verzerrung der Regelgenauigkeit führt.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModulmontage und Erdung der Basis:\u003c\/strong\u003e Schieben Sie das AT4222-Modul vertikal in den passenden X20-Basisanschlussblock, bis die Kunststoffverriegelungen mit einem deutlichen Klick einrasten. Vergewissern Sie sich, dass die DIN-Schiene, auf der die Baugruppe montiert ist, ordnungsgemäß mit der zentralen Erdung des Schaltschrankes verbunden ist, um einen niederohmigen Pfad für die Kabelabschirmungen zu gewährleisten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370660715,"sku":"AT4222","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/at4222-bv2ency0kuq.png?v=1776137294"},{"product_id":"b-r-x20at6402-x20-system-6-channel-thermocouple-input-module","title":"B\u0026R X20AT6402 X20 System 6-Kanal Thermoelement-Eingangsmodul","description":"\u003ch3\u003eTechnische Beschreibung und Rolle bei der Temperaturverarbeitung\u003c\/h3\u003e\n\u003cp\u003eDas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AT6402 (X20AT6402)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein industrielles Temperaturmessmodul, das für die modulare B\u0026amp;R X20 System-Automatisierungsplattform entwickelt wurde. Es ist für hochpräzise Temperaturüberwachung in extremen Prozessumgebungen ausgelegt – wie Spritzgießmaschinen, industrielle Backöfen, chemische Reaktoren und Metallschmelzöfen. Dieses Modul bietet sechs unabhängige Eingangskanäle, die speziell für Thermoelement-Sensoren kalibriert sind. Es verfügt über eine hochgenaue 16-Bit-Analog-Digital-Wandler-Auflösung (ADC), die Mikrovolt-Änderungen an Thermoelementübergängen erfasst und in präzise digitale Werte umwandelt. Die Integration dieses Hardwaremoduls in Ihr Steuerungssystem gewährleistet stabile thermische Datenrückmeldungen, filtert hochfrequente induktive Störungen von Heizelementen heraus und schützt vor unerwartetem thermischem Durchgehen, das Systemschäden verursachen kann.\u003c\/p\u003e\n\u003ch3\u003eSignalqualität und elektrische Infrastruktur\u003c\/h3\u003e\n\u003cp\u003eMit dem offiziellen B\u0026amp;R ID-Code 0x1B96 ausgestattet, verfügt dieses I\/O-Modul über einen einstellbaren Eingangskanalfilter mit einer softwarekonfigurierbaren Filterzeitkonstante von 1 ms bis 66,7 ms. Diese anpassbare Filterung ermöglicht es Anlageningenieuren, je nach den spezifischen Dynamiken des Temperaturregelkreises eine Balance zwischen ultraschnellen Reaktionszeiten und maximaler Rauschunterdrückung zu finden. Der Stromverbrauch des Moduls ist hochoptimiert und zieht nur minimal 0,01 W von den X20 Backplane-Bus-Logikleitungen und maximal 0,91 W von der internen I\/O-Stromversorgung. Onboard-Hardware-Diagnosearrays verwenden klare LED-Anzeigen, um Echtzeit-Updates zu einzelnen Kanal-I\/O-Funktionen, lokalen Betriebszuständen und dem Gesamtzustand des Moduls bereitzustellen.\u003c\/p\u003e\n\u003ch3\u003eLeistung und Sensorspezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eBetriebsparameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20AT6402\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Temperaturmessung\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEingangskanäle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Eingänge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor-Kompatibilität\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermoelement-Sensoren\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R ID-Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0x1B96\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWandlerauflösung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Bit digitale Auflösung\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKonfigurierbare Filterzeit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 ms bis 66,7 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus-Stromverbrauch\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,01 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterne I\/O-Stromversorgung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,91 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnose\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED-Anzeigen für Kanal, Zustand und Modul\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebsfeuchtebereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBruttoversandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,0 kg (verpackt in schwerer Schutz- und Versandverpackung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ zur industriellen Hardware\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEnthält das X20AT6402 eine interne Kaltstellenkompensation (CJC)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Um genaue Thermoelement-Temperaturmessungen zu gewährleisten, implementiert das X20 System eine absolute Kompensation. Die Kaltstellen-Temperaturreferenz wird entweder über den Sensor am Klemmenblock oder einen zentralen Kompensationskanal verwaltet, der in B\u0026amp;R Automation Studio konfiguriert wird.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas passiert, wenn ein Thermoelement-Draht während des Betriebs reißt oder sich löst?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul verfügt über eine integrierte Leerlauf-Erkennung. Wenn ein Thermoelement-Draht reißt, steigt der Kanalwiderstand auf unendlich, wodurch das Modul einen Fehlerbyte auf dem Systembus registriert und die Fehler-LED des betroffenen Kanals aufleuchtet, um die Bediener zu alarmieren.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann ich verschiedene Thermoelementtypen (z. B. Typ J und Typ K) am selben Modul mischen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Jeder Kanalparameter wird unabhängig in B\u0026amp;R Automation Studio verwaltet. Sie können einzelne Kanäle für spezifische Thermoelement-Linearitätskurven konfigurieren, sofern die ausgewählten Typen von der Modul-Firmware unterstützt werden.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFeldinbetriebnahme- und Installationsrichtlinien\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtokolle für Verlängerungsleitungen und Abschirmung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThermoelement-Signale arbeiten im niedrigen Millivoltbereich und sind sehr anfällig für elektromagnetische Störungen (EMI). Verwenden Sie stets passende Thermoelement-Verlängerungs- oder Kompensationsleitungen, um den Sensor mit dem X20-Klemmenblock zu verbinden. Führen Sie diese Signalleitungen in separaten Niederspannungs-Kabelkanälen, vollständig getrennt von Hochspannungs-Wechselstromleitungen oder Frequenzumrichterkabeln.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilterkalibrierung zur Rauschminderung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn Umgebungen mit schweren industriellen SCR-Leistungsreglern für elektrische Heizelemente stellen Sie die konfigurierbare Filterzeit auf den Grenzwert von 66,7 ms ein. Diese Einstellung nutzt die integrierten Tiefpass-Digitalfilter, um 50-Hz- und 60-Hz-Netzstörungen zu eliminieren und saubere, stabile Temperaturverläufe zu gewährleisten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminalbasis-Sitz und mechanische Sicherung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSetzen Sie das X20AT6402-Modul vertikal in das passende X20-Basismodul ein, bis die mechanischen Verriegelungsklammern vollständig einrasten. Stellen Sie sicher, dass die Schrauben oder Federklemmen des Klemmenblocks fest an den blanken Kupferleitern angezogen sind, um Kontaktwiderstandsschwankungen zu vermeiden, die zu Messabweichungen oder Fehlern führen können.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370726251,"sku":"X20AT6402","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20at6402-kkqogw0d5kt.png?v=1776138134"},{"product_id":"b-r-x20hb8815-x20-system-powerlink-to-tcp-ip-gateway-module","title":"B\u0026R X20HB8815 X20 System POWERLINK zu TCP\/IP Gateway-Modul","description":"\u003ch3\u003eTechnische Beschreibung und Gateway-Routing-Logik\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20HB8815 (X20HB8815)\u003c\/strong\u003e ist ein industrielles Kommunikationsgateway, das für die modulare B\u0026amp;R X20 Systemplattform entwickelt wurde. Dieses Modul fungiert als hocheffizienter POWERLINK Controlled Node, der deterministische, echtzeitfähige industrielle Ethernet-Schleifen mit standardmäßigen nicht-echtzeitfähigen TCP\/IP-Netzwerkinfrastrukturen verbindet. Es ist für komplexe Automatisierungsanwendungen konzipiert – wie großflächige Automobilmontagelinien, kommunale Wasserversorgungssysteme und Steuerungsarchitekturen von Kraftwerken – bei denen Sensordaten und Antriebsdaten auf Feldebene transparent an übergeordnete SCADA-, MES- oder Unternehmensnetzwerke weitergeleitet werden müssen. Die zugrundeliegende Hardware-Architektur umfasst eine integrierte Erweiterungsschnittstelle mit bis zu zwei dedizierten Steckplätzen für Hub-Erweiterungsmodule, die es Anlageningenieuren ermöglichen, lokale Netzwerktopologien dynamisch zu skalieren, ohne separate eigenständige Switch-Hardware hinzuzufügen.\u003c\/p\u003e\n\u003ch3\u003eNetzwerkschnittstelle und elektrische Architektur\u003c\/h3\u003e\n\u003cp\u003eDie physische Schnittstelle des Gateways verfügt über zwei geschirmte RJ45-Anschlüsse, die standardmäßige Segmentlängen von bis zu 100 Metern zwischen Kommunikationsstationen unterstützen. Das Modul verwaltet über diese Anschlüsse zwei unterschiedliche Netzwerkschichten: einen Hochgeschwindigkeits-POWERLINK-Echtzeitkanal mit einer festen Übertragungsrate von 100 Mbit\/s und einen standardmäßigen TCP\/IP-Kanal mit automatischer Aushandlung von 10\/100 Mbit\/s. Für den Dauerbetrieb in hochverdichteten elektrischen Gehäusen ausgelegt, weist das Modul eine geringe thermische Belastung auf und zieht maximal 2 W Leistung vom Backplane-Bus. Die integrierten Diagnoseanzeigen verfügen über klare LED-Statusanzeigen, die Echtzeit-Visualisierungen des Gesamtmodulzustands und der aktiven Buskommunikationsfunktion bieten.\u003c\/p\u003e\n\u003ch3\u003eLeistungs- und Netzwerkspezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20HB8815\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Kommunikationsgateway\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKnotenfunktion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOWERLINK Controlled Node\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eErweiterungsmöglichkeiten\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBis zu 2 Steckplätze für Hub-Erweiterungsmodule\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysische Schnittstelle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2x geschirmte RJ45-Anschlüsse\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximale Segmentlänge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 m zwischen 2 Stationen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOWERLINK Übertragungsrate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTCP\/IP Übertragungsrate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 \/ 100 Mbit\/s (Auto-Negotiation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLeistungsaufnahme\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware-Diagnose\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOnboard-LEDs für Modulstatus und Busfunktion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBruttoversandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,5 kg (eingeschlossen in elektrostatischer Entladungsschirmung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ zur Integration in die Technik\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist der primäre architektonische Zweck des Einsatzes des X20HB8815 Gateways?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul fungiert als verwaltete Firewall und Datenbrücke zwischen Ihrer Echtzeit-Maschinensteuerungsschleife (POWERLINK) und Ihrem Anlagenetzwerk (TCP\/IP). Es ermöglicht das Auslesen von Parametern, Diagnosespuren und Betriebsdaten durch externe Software, ohne dass Standard-Netzwerk-Broadcast-Stürme die Mikrosekunden-genaue Synchronisation der Maschinenantriebe stören.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie funktionieren die beiden Erweiterungssteckplätze am Gateway?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie zwei integrierten Erweiterungssteckplätze nehmen zusätzliche X20 Hub-Erweiterungsmodule auf (z. B. Glasfaser-Schnittstellen). Dadurch können Sie die physischen Medientypen und Portdichte direkt am Gateway-Knoten anpassen, ohne einen externen eigenständigen Industrieswitch zu benötigen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses Gateway als POWERLINK Managing Node (Master) fungieren?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein. Das X20HB8815 ist ausschließlich als POWERLINK Controlled Node (Slave) vorgesehen. Es benötigt eine primäre X20 CPU oder einen fortschrittlichen Master-Controller, um die zyklische Netzwerkscheduling über das lokale Bussegment zu steuern.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFeldinbetriebnahme- und Einsatzrichtlinien\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAbschirmung und Kabelverlegung:\u003c\/strong\u003e Da POWERLINK mit hohen Geschwindigkeiten kommuniziert, müssen Sie industrielle Category 5e (oder höher) doppelt geschirmte verdrillte Adernpaare (S\/FTP) verwenden. Stellen Sie sicher, dass die äußere Metallflechtung des RJ45-Steckers sauberen Kontakt mit der geschirmten Buchse des X20HB8815 hat, um einen niederohmigen Erdungspfad zu gewährleisten und elektromagnetische Störungen (EMI) zu verhindern, die Echtzeit-Datenpakete beeinträchtigen könnten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSicherheit bei der Installation von Erweiterungsmodulen:\u003c\/strong\u003e Trennen Sie vor dem Einsetzen oder Entfernen von Hub-Erweiterungsmodulen in den Zusatzsteckplätzen des X20HB8815 vollständig die 24 VDC-Stromversorgung des lokalen X20-Racks. Änderungen an der Hardware-Konfiguration bei eingeschaltetem Backplane können Mikrolichtbögen an den Steckerkontakten verursachen, die die interne Routing-Logik dauerhaft beschädigen können.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetzwerksegmentierung:\u003c\/strong\u003e Beim Konfigurieren der TCP\/IP-Schnittstelle für SCADA- oder MES-Datenzugriff planen Sie Ihre IP-Adresszuweisungen sorgfältig in B\u0026amp;R Automation Studio. Halten Sie Ihre Echtzeit-Prozessbildvariablen getrennt von umfangreichen asynchronen Datenübertragungen, um niedrige Jitterwerte und deterministische Leistung im primären POWERLINK-Netzwerksegment zu gewährleisten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370791787,"sku":"X20HB8815","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20hb8815-ncfcbmq2kpu.png?v=1776138201"},{"product_id":"b-r-x20hb1881-x20-system-fiber-optic-hub-expansion-module","title":"B\u0026R X20HB1881 X20 System Glasfaser-Hub Erweiterungsmodul","description":"\u003ch3\u003eTechnische Beschreibung und Netzwerkanwendung\u003c\/h3\u003e\n\u003cp\u003eDas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20HB1881 (X20HB1881)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein industrietaugliches Glasfaser-Hub-Erweiterungsmodul, das für die modulare B\u0026amp;R X20 Systemplattform entwickelt wurde. Es ist darauf ausgelegt, Hochgeschwindigkeits-Ethernet-Kommunikation über lange physikalische Distanzen zu erweitern und eignet sich besonders für dezentrale Verarbeitungsumgebungen wie Kläranlagen, Fertigungshubs mit mehreren Gebäuden und Tagebaubetriebe. Es integriert eine 100 BASE-FX Hub-Schnittstelle, die für Multimode-Glasfaserkabel ausgelegt ist und eine Betriebsübertragungsreichweite von bis zu 2 km ohne Signalverschlechterung bietet. Durch die Umwandlung elektrischer Bussignale in optische Signale gewährleistet das Modul eine vollständige elektrische Trennung zwischen der Stromversorgung und dem Ethernet-Netzwerk. Diese Konstruktion schützt die Kernautomatisierungsinfrastruktur vor Erdschleifenströmen, Hochspannungsspitzen und starken elektromagnetischen Störungen (EMI).\u003c\/p\u003e\n\u003ch3\u003eNetzwerkarchitektur und Schnittstellenlogik\u003c\/h3\u003e\n\u003cp\u003eDas Modul arbeitet mit einer deterministischen Datenübertragungsrate von 100 Mbit\/s und verfügt über eine physikalische Schnittstelle mit einem Duplex-LC-Buchsenanschluss für eine stabile Glasfaser-Ausrichtung. Die Hardware des Moduls unterstützt vollständiges Hot-Swapping, sodass Wartungspersonal die Komponente während des laufenden Systembetriebs austauschen kann, ohne die Kommunikationsverbindung benachbarter I\/O-Slices zu unterbrechen. Die integrierten Diagnoseanzeigen verfügen über klare LED-Indikatoren, die Echtzeit-Updates zum Gesamtstatus des Moduls und zur aktiven Busfunktion anzeigen. Das Modul ist für einen niedrigen thermischen Fußabdruck ausgelegt und zieht maximal 1,45 W Leistung (ältere Revisionen vor DO bis zu 1,65 W) vom System-Backplane-Bus, wodurch eine geringe interne Wärmeentwicklung im Baugruppenträger gewährleistet wird.\u003c\/p\u003e\n\u003ch3\u003eLeistungs- und Netzwerkspezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20HB1881\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Kommunikations-Hub\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSchnittstellenport\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x 100 BASE-FX Hub\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSteckervariante\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x Buchse Duplex LC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMedientyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultimode-Glasfaserkabel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximale Übertragungsdistanz\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBis zu 2 km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDatenübertragungsgeschwindigkeit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElektrische Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet-Netzwerk vom Netzteil isoliert\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot-Swap-Unterstützung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJa (vollständig hot-swap-fähig)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLeistungsaufnahme\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 1,45 W (Revisionen vor DO: max. 1,65 W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware-Diagnose\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOnboard-LEDs für Modulstatus und Busfunktion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBruttoversandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,5 kg (eingeschlossen in elektrostatischer Entladungsschutzverpackung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ zur technischen Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWelche spezifischen Vorteile bietet der Glasfaser-X20HB1881 gegenüber Standard-Kupfer-RJ45-Modulen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard-Kupfer-Ethernetkabel sind auf 100 Meter begrenzt und anfällig für elektromagnetische Störungen durch leistungsstarke Frequenzumrichter (VFDs) und schwere Maschinen. Das X20HB1881 verwendet Multimode-Glasfaser, die die Netzwerkreichweite auf bis zu 2 km erweitert und dabei vollständig immun gegen industrielle EMI, Übersprechen und durch Blitze induzierte Spannungsspitzen bleibt.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnterbricht das Hot-Swapping des X20HB1881 das Kommunikationsnetzwerk anderer Module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein. Die X20-Backplane-Architektur ermöglicht es, das X20HB1881 zu entnehmen und einzusetzen, während der Rest des Racks mit Strom versorgt bleibt. Allerdings wird jede aktive Glasfaser-Datenkommunikation, die direkt über dieses spezifische Modul läuft, unterbrochen, bis die Ersatzkarte eingesetzt und initialisiert ist.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses Modul mit Singlemode-Glasfaserkabeln verwendet werden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein. Der optische Transceiver im X20HB1881 ist ausschließlich auf die Welleneigenschaften und Kerndurchmesser von Multimode-Glasfaserkabeln abgestimmt. Eine Verbindung mit Singlemode-Fasern führt zu starker optischer Dämpfung und Kommunikationsausfällen.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFeldinbetriebnahme und optoelektronische Richtlinien\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSchutz und Sauberkeit der optischen Schnittstelle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStaubpartikel in der Luft und Fingeröle können die kleinen optischen Öffnungen des Duplex-LC-Steckers blockieren. Halten Sie die schützenden Gummikappen stets installiert, bis die Feldkabel zur endgültigen Einsteckung bereit sind. Reinigen Sie die Faserendflächen vor dem Einstecken mit einem dafür vorgesehenen industriellen Glasfaser-Reinigungswerkzeug.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBiegeradiusgrenzen für Glasfaserkabel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeim Verlegen der Multimode-Glasfaserkabel im Schaltschrank ist der vom Hersteller angegebene minimale Biegeradius strikt einzuhalten (typischerweise mindestens das 20-fache des Kabeldurchmessers unter Zugspannung). Scharfe Biegungen verursachen Mikrorisse im Glasfaserkern, was zu hohen Signalverlusten und sporadischem Paketverlust führt.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane-Einbau und Ausrichtung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeim Nutzen der Hot-Swap-Fähigkeit schieben Sie das Modul sanft in den X20-Basisterminalblock. Stellen Sie sicher, dass die integrierten Verriegelungsklammern sicher am Schienenprofil einrasten, um mechanische Vibrationen zu verhindern, die den optischen Transceiver relativ zur Backplane-Verbindung verschieben könnten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370857323,"sku":"X20HB1881","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20hb1881-ncsqgvciju1.png?v=1776138201"},{"product_id":"b-r-x20do4649-x20-system-4-channel-isolated-relay-output-module","title":"B\u0026R X20DO4649 X20 System 4-Kanal Isoliertes Relais-Ausgangsmodul","description":"\u003ch3\u003eTechnische Beschreibung und Anwendung\u003c\/h3\u003e\n\u003cp\u003eDas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20DO4649 (X20DO4649)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein robustes 4-Kanal-Relais-Ausgangsmodul, das für die modulare B\u0026amp;R X20 Systemplattform entwickelt wurde. Es wurde konzipiert, um Niederspannungs-Steuerlogik mit leistungsstarken Feldaktuatoren zu verbinden und eignet sich hervorragend für raue Prozessumgebungen wie Energieverteilungsanlagen, petrochemische Werke und schwere Fertigungslinien. Es verfügt über vier unabhängige normalerweise offene (NO) Relaiskontakte, die Dauerlasten bis zu 5 A bei 240 VAC oder 30 VDC schalten können. Jeder Kanal ist mit vollständiger Einzelkanal-Elektroisolation ausgestattet, was bedeutet, dass die einzelnen Ausgänge vollständig voneinander, vom internen Systembus und von der I\/O-Stromversorgung isoliert sind. Diese robuste Konfiguration verhindert, dass elektrische Fehler von einem Kanal auf andere Kanäle im Automatisierungsrack übergreifen, gewährleistet maximale Systemverfügbarkeit und minimiert das Risiko katastrophaler Hardwareausfälle.\u003c\/p\u003e\n\u003ch3\u003eFunktionale Architektur und Schaltleistung\u003c\/h3\u003e\n\u003cp\u003eDas Modul arbeitet über ein flexibles Spannungsspektrum und unterstützt Schaltspannungen bis zu 110 VDC oder 264 VAC innerhalb eines Nennfrequenzbereichs von Gleichstrom und 45 bis 63 Hz. Die hochkapazitiven internen Relaiskontakte halten einen niedrigen Anfangskontaktwiderstand von unter 100 mΩ, was die lokale thermische Dissipation unter maximaler Last minimiert. Während einzelne Kanäle einen Nennstrom von 5 A unterstützen, schreibt die Modularchitektur eine strikte Gesamt-Nennstrombegrenzung von 10 A für die gesamte Einheit vor, um das thermische Gleichgewicht im I\/O-Stack zu gewährleisten. Onboard-Hardware-Diagnosearrays verwenden klare LED-Anzeigen, um Echtzeit-Updates zu einzelnen Kanal-I\/O-Funktionen, lokalen Betriebszuständen und dem allgemeinen Modulzustand bereitzustellen.\u003c\/p\u003e\n\u003ch3\u003eLeistungs- und elektrische Spezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20DO4649\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Relaisausgang\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnzahl der Kanäle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Ausgänge (normalerweise offene Kontakte)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAusgangs-Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEinzelkanal vollständig isoliert\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNenn-Schaltspannung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 VDC \/ 240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximale Schaltspannung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 VDC \/ 264 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNenn-Betriebsfrequenz\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGleichstrom \/ 45 bis 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNenn-Ausgangsstrom\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A pro Kanal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGesamtsummationsstrom\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 10 A pro Modul\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpitzen-Einschaltstrom\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKontaktwiderstand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 100 mΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStellantriebs-Stromversorgung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExterne Stromversorgung erforderlich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatusanzeigen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED-Anzeigen für Kanal, Zustand und Modul\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebsfeuchtigkeitsgrenzen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBruttoversandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,0 kg (inklusive robuster Schwerlastverpackung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ zur technischen Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eKann das X20DO4649 AC- und DC-Lasten auf verschiedenen Kanälen desselben Moduls mischen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Da jeder Kanal elektrisch vollständig von den anderen isoliert ist, können Sie eine 240 VAC-Motorschützspule auf Kanal 1 schalten und gleichzeitig eine 24 VDC-Anzeigenlampenschleife auf Kanal 2 betreiben, ohne Gefahr von Phasenkopplung oder Leckströmen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist die Funktion der externen Aktuator-Stromversorgungsanforderung?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer interne X20-Systembus liefert nur niederenergetische Logiksignale zum Auslösen der internen Relais-Spulen. Die tatsächliche Energie zur Ansteuerung der nachgeschalteten Feldkomponenten (Ventile, Schütze, Alarme) muss von einer externen Stromquelle über die Relaiskontakte bereitgestellt werden.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie signalisiert das Modul einen mechanischen Relaisfehler?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul registriert Funktionsdiagnosen über den Systembus. Wenn der vom CPU vorgegebene interne Logikzustand nicht mit dem über die interne Relais-Spulenschaltung überwachten Spannungszustand übereinstimmt, meldet das Modul einen Statusfehlercode an B\u0026R Automation Studio und leuchtet die lokale Fehler-LED auf.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFeldinbetriebnahme und Sicherheitsprotokolle\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEinschaltstrom- und Überspannungsunterdrückung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelaiskontakte sind anfällig für Lichtbögen und Materialausbrüche beim Schalten stark induktiver oder kapazitiver Lasten. Beim Steuern schwerer induktiver Geräte wie AC-Magnetventilen installieren Sie eine passend abgestimmte RC-Dämpfungsschaltung über den Kontakten. Für DC-induktive Lasten verwenden Sie eine Freilaufdiode, um hohe induktive Spannungsspitzen beim Abschalten abzufangen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGesamtstrombudgetverwaltung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStellen Sie sicher, dass der kumulative Strom aller vier Kanäle das nominale Gesamtlimit von 10 A nicht überschreitet. Wenn Ihre Anwendung verlangt, dass drei Kanäle gleichzeitig 4 A führen (\u003cspan class=\"math-inline\"\u003e$4\\text{ A} \\times 3 = 12\\text{ A}$\u003c\/span\u003e), überschreiten Sie die thermischen Grenzen des Moduls; verteilen Sie in solchen Fällen die Last auf mehrere X20DO4649-Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminalverkabelungsstandards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIsolieren Sie Feldleitungen sorgfältig ab und verwenden Sie hochwertige, gecrimpte Aderendhülsen, um zu verhindern, dass ausgefranste Litzen die schmale Lücke zwischen benachbarten isolierten Klemmenblöcken überbrücken. Befestigen Sie alle Hochspannungsanschlüsse fest in den Federklemmen, um den Übergangswiderstand zu minimieren und lokale Hitzeentwicklungen zu vermeiden.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086371086699,"sku":"X20DO4649","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20do4649-zphefcttdey.png?v=1776138189"},{"product_id":"b-r-x20if1061-1-x20-system-profibus-dp-master-interface-module","title":"B\u0026R X20IF1061-1 X20 System PROFIBUS DP Master Schnittstellenmodul","description":"\u003ch3\u003eTechnische Beschreibung und Betriebsrolle\u003c\/h3\u003e\n\u003cp\u003eDas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20IF1061-1 (X20IF1061-1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein leistungsstarkes industrielles Kommunikationsschnittstellenmodul, das für die direkte Integration in die B\u0026amp;R X20 Systemsteuerungsarchitektur entwickelt wurde. Es wurde konzipiert, um deterministische Feldbusverbindungen in dezentralen Verarbeitungsanlagen – wie Wasseraufbereitungsanlagen, chemischen Verarbeitungsbetrieben und Automobilfertigungslinien – herzustellen. Dieses Modul fungiert als vollwertige PROFIBUS DP V0\/V1 Master-Schnittstelle. Es bietet umfassende Unterstützung für Field Device Tool \/ Device Type Manager (FDT\/DTM) Konfigurationsrahmen, die es Ingenieuren ermöglichen, komplexe intelligente Feldgeräte direkt aus der zentralen Steuerungsumgebung zu kalibrieren, zu diagnostizieren und zu überwachen. Die integrierten Kommunikationsanschlüsse verfügen über eine robuste elektrische Trennung, die die empfindliche interne CPU-Rückplanelektronik vor Spannungstransienten auf der Feldseite schützt und lokale Masseschleifenströme eliminiert.\u003c\/p\u003e\n\u003ch3\u003eDiagnosematrix und Infrastruktur-Logik\u003c\/h3\u003e\n\u003cp\u003eDieses Schnittstellenmodul verfügt über eine zweistufige Überwachungsfunktion, die sowohl hardwarebasierte LED-Anzeigen als auch softwarezugängliche Register für die Echtzeit-Fehlerverfolgung bietet. Die an Bord befindlichen visuellen Anzeigen ermöglichen eine sofortige Diagnoseüberprüfung über drei Betriebsebenen: Modulzustand, Netzwerksynchronisationsintegrität und aktive Datenübertragungszyklen. Das Modul ist für einen niedrigen Stromverbrauch ausgelegt und zieht maximal 1,8 W vom zugrundeliegenden Systembus, wodurch die interne Wärmeentwicklung im Baugruppenstapel minimiert wird. Das Modul arbeitet zuverlässig in feuchten Umgebungen und ist für einen Betriebs- und Lagerbereich von 5 bis 95 % nicht kondensierender Luftfeuchtigkeit ausgelegt, um eine stabile Langzeit-Datenübertragung ohne Kommunikationsverlust zu gewährleisten.\u003c\/p\u003e\n\u003ch3\u003eTechnische Leistungsspezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSchnittstellenparameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20IF1061-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Schnittstellenkommunikation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtokollunterstützung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DP V0 \/ V1 Master\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKonfigurationsmodell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDTM-basierte Instrumentenintegration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElektrische Trennung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJa (Netzwerkseite zum Systembus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLeistungsaufnahme\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 1,8 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware-Diagnose\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED-Anzeigen für Modul, Netzwerk und Daten\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware-Diagnose\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterne Statusregister über SPS zugänglich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebsfeuchtigkeitsgrenzen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLager- \/ Transportfeuchtigkeit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetto-Gerätemasse\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCa. 0,12 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBruttoversandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,0 kg (eingeschlossen in robustem Transportschutz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ zur industriellen Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist der praktische Unterschied zwischen der PROFIBUS DP V0- und V1-Funktionalität bei diesem Modul?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePROFIBUS DP V0 verarbeitet den schnellen, zyklischen I\/O-Datenaustausch für Standard-Digital- und Analogsignale. Die DP V1-Funktionalität führt azyklische Parameterkommunikation ein, die es dem X20IF1061-1 ermöglicht, Instrumentenkonfigurationen zu ändern, erweiterte Diagnosen auszulesen und mit intelligenten DTM-Feldgeräten zu interagieren, während die zyklische Verarbeitung ununterbrochen weiterläuft.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses Modul zusammen mit anderen Kommunikationsmodulen im selben X20-Rack verwendet werden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Mehrere Schnittstellenmodule können innerhalb derselben X20-Steuerungsstruktur betrieben werden, vorausgesetzt, die Gesamtleistungsaufnahme überschreitet nicht die Kapazität der Haupt-CPU oder der Hilfsstromversorgungsmodule. Jedes Modul wird in B\u0026amp;R Automation Studio unabhängig adressiert.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnthält das X20IF1061-1 einen internen PROFIBUS-Leitungsabschlusswiderstand?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein. Die physikalische Busabschlusswiderstand muss am externen PROFIBUS-Netzwerkstecker vorgenommen werden. Stellen Sie sicher, dass der Abschluss-Schalter am DB9 Sub-D-Stecker auf die aktive („ON“) Position gestellt ist, wenn dieses Modul am physischen Ende des Feldbus-Leitungssegments platziert wird.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFeldtechnik- und Inbetriebnahmerichtlinien\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetzwerkkabelschirmung und Erdung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePROFIBUS DP-Leitungen arbeiten mit Übertragungsgeschwindigkeiten bis zu 12 Mbps und sind sehr empfindlich gegenüber hochfrequenten elektromagnetischen Störungen. Verwenden Sie standardmäßige violette Typ A geschirmte verdrillte Adernpaare. Entfernen Sie die Außenisolierung sorgfältig und erden Sie den geflochtenen Kupferschirm vollständig an der metallischen DIN-Schienen-Schnittstelle mit niederohmigen Erdungsklemmen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStationsadressenzuweisungsprotokoll:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eErstellen Sie vor der Initialisierung des PROFIBUS-Netzwerkmasters über Automation Studio eine saubere Übersicht aller angeschlossenen Slave-Knotenadressen. Stellen Sie sicher, dass kein Slave-Knoten dieselbe Adresse wie der X20IF1061-1 Master verwendet, und begrenzen Sie die maximale Knotenspanne, um deterministische Zykluszeiten im Netzwerk zu gewährleisten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDTM-Geräteverwaltungsabstimmung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeim Einbinden von Instrumenten von Drittanbietern (wie Ventile, Durchflussmesser oder Antriebe) importieren Sie die entsprechenden gerätespezifischen GSD- und DTM-Dateien in Ihr Konfigurationsverzeichnis. Dies stellt sicher, dass die erweiterten azyklischen Parameterkanäle, die vom DP V1-Protokoll bereitgestellt werden, korrekt auf die internen Steuerungsvariablen abgebildet werden.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086371152235,"sku":"X20IF1061-1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20if1061-1-sgufc1gkasc.png?v=1776138205"},{"product_id":"b-r-x20if2772-x20-system-interface-communication-module","title":"B\u0026R X20IF2772 X20 System Schnittstellen-Kommunikationsmodul","description":"\u003ch3\u003eTechnische Beschreibung und Funktionale Rolle\u003c\/h3\u003e\n\u003cp\u003eDas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20IF2772 (X20IF2772)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein dediziertes Schnittstellen-Kommunikationsmodul, das für die direkte Slot-Integration in ein B\u0026amp;R X20 CPU-System entwickelt wurde. Es wurde konzipiert, um die Netzwerkkapazitäten lokaler Steuerungen in komplexen Automatisierungsnetzwerken – wie kommunalen Wasseraufbereitungen, petrochemischen Prozessen und automatisierten Montagelinien – zu erweitern. Dieses Modul stellt eine zuverlässige Datenbrücke zwischen der Hauptsteuerung und zusätzlichen Feldgeräten her. Mit einer optimierten internen Prozessorarchitektur verwaltet das Modul eigenständig dedizierte Feldbus-Kommunikationsroutinen und entlastet so die Haupt-CPU von Netzwerk-Stack-Überlastungen. Die Integration dieser industriellen Kommunikationsschnittstelle in Ihre Rack-Konfiguration garantiert deterministische Datenaustauschraten, schützt vor Paketverschlechterung und reduziert unerwartete Maschinen-Kommunikationszeitüberschreitungen.\u003c\/p\u003e\n\u003ch3\u003eDiagnose und Schnittstellenarchitektur\u003c\/h3\u003e\n\u003cp\u003eMit dem offiziellen B\u0026amp;R ID-Code 0x1F25 ausgestattet, verfügt dieses Modul über integrierte Hardware-Diagnosen, die eine Echtzeit-Statusverfolgung über lokal angeordnete LED-Anzeigen ermöglichen. Die Schnittstellenkonfiguration bietet Ingenieuren eine sofortige visuelle Bestätigung in drei kritischen Parametern: Gesamtzustand des Moduls, aktive Datenübertragungszyklen und den aktuellen Zustand des integrierten Abschlusswiderstands. Das Modul arbeitet mit einer niedrigen thermischen Signatur und verbraucht maximal 1,2 W vom Systembus, wodurch die Leistungsbilanz für benachbarte I\/O-Module am selben Knoten erhalten bleibt. Die physische Schnittstelle erfordert zwei TB2105 Klemmenblöcke (separat zu bestellen), um die Feldverkabelung direkt an der Oberfläche des Steckmoduls zu befestigen.\u003c\/p\u003e\n\u003ch3\u003eFunktionale Leistungsspezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSchnittstellenparameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20IF2772\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System-Kommunikationsschnittstelle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R ID-Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0x1F25\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKompatibler Slot\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDirekter Integrationsslot in X20 CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLeistungsaufnahme\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 1,2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulstatus-Diagnose\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrierte LED-Statusanzeige\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDatenübertragungs-Diagnose\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrierte LED-Statusanzeige\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAbschlusswiderstands-Diagnose\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrierte LED-Statusanzeige\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eErforderliche Anschluss-Hardware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2x Klemmenblock TB2105 (nicht enthalten)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolationsbarriere\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanische Trennung zwischen Netzwerk und CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebliche Luftfeuchtigkeitsgrenzen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLagerungstemperaturbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 bis 55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBruttoversandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,0 kg (inklusive schützender antistatischer Verpackung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ zur technischen Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWo genau im X20-Rack wird das X20IF2772 installiert?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas X20IF2772 ist kein I\/O-Slice-Modul; es ist speziell dafür ausgelegt, in den dedizierten Schnittstellen-Slot direkt am Gehäuse eines X20 CPU-Controllers eingesetzt zu werden. Strom- und Datenbusverbindungen werden über die CPU-Rückwandverbindung hergestellt.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist der Zweck der LED-Anzeige für den Abschlusswiderstand?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie LED für den Abschlusswiderstand bietet eine aktive Überprüfung des physischen Leitungsabschlusses. In industriellen Netzwerken mit langen Leitungen führt eine falsche Terminierung zu Signalreflexionen und Paketbeschädigungen; diese Anzeige ermöglicht es Feldtechnikern, fehlerhafte Leitungs-Konfigurationen sofort zu erkennen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses Modul ohne die TB2105 Klemmenblöcke betrieben werden?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Modulelektronik wird im CPU-Slot mit Strom versorgt, aber ohne die Klemmenblöcke können keine physischen Kommunikationsleitungen angeschlossen werden. Sie müssen zwei separate TB2105 Klemmenblöcke beschaffen, um die Netzwerkkabel korrekt anzuschließen.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFeldinbetriebnahme- und Einsatzrichtlinien\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBussegment-Abschlussprotokoll:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWenn Sie dieses Schnittstellenmodul am physischen Ende einer Kommunikationsnetzwerkleitung positionieren, aktivieren Sie den Abschlusswiderstand über Ihre Systemkonfigurationssoftware. Stellen Sie sicher, dass die LED für den physischen Abschlusswiderstand leuchtet, um zu bestätigen, dass das interne Widerstandsnetzwerk die Leitung gegen elektrische Störungen abschirmt.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSicherheitsstandards beim Moduleinsetzen:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSchalten Sie immer die Stromversorgung der übergeordneten X20 CPU aus, bevor Sie das X20IF2772 Modul in den Schnittstellen-Slot einsetzen oder herausnehmen. Das Handling der Schnittstellen-Hardware bei eingeschaltetem Bus kann Mikrolichtbögen an den Rückwand-Pins verursachen, was zu Datenkorruption oder Chipschäden führt.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAbschirmungsausrichtung der Anschlusskabel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeim Vorbereiten der Kommunikationskabel für die TB2105 Klemmenblöcke entfernen Sie die äußere Isolierung und erden Sie die Geflechtschirmung vollständig am vorgesehenen Gehäuse-Erdungspunkt innerhalb des Gehäuses. Halten Sie ungeschirmte Drahtabschnitte so kurz wie möglich, um die Signalqualität in lärmintensiven Fabrikumgebungen zu erhalten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086371381611,"sku":"X20IF2772","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20if2772-xapic12tz2l.png?v=1776138209"},{"product_id":"b-r-x20cp1484-1-x20-system-controller-cpu-module","title":"B\u0026R X20CP1484-1 X20 System Controller CPU-Modul","description":"\u003ch3\u003eRechenleistung und industrielle Anwendung\u003c\/h3\u003e\n\u003cp\u003eDer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP1484-1 (X20CP1484-1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eist ein leistungsstarker industrieller CPU-Controller, der als zentrale Verarbeitungseinheit für komplexe B\u0026amp;R X20-Automatisierungsarchitekturen konzipiert wurde. Speziell ausgelegt für anspruchsvolle Prozesssteuerungen, Hochgeschwindigkeits-Materialhandling, Überwachung der Energieerzeugung und komplexe Fertigungslinien, führt dieser Embedded-Controller synchrone Bewegungssteuerung und präzise Logikberechnungen aus. Er verfügt über ein lüfterloses Kühldesign, das mechanische Verschleißpunkte eliminiert und Ausfälle innerer Komponenten durch luftgetragene Partikel verhindert. Die Integration dieses robusten Controllers in Ihr zentrales Steuersystem schafft eine hochresiliente Architektur, die zyklische Scanzeiten minimiert, Kommunikationslatenzen reduziert und kritische Infrastrukturen vor unkontrollierten Prozessunterbrechungen schützt.\u003c\/p\u003e\n\u003ch3\u003eSysteminfrastruktur und Netzwerkschnittstelle\u003c\/h3\u003e\n\u003cp\u003eBasierend auf einem effizienten, Celeron 266-kompatiblen Prozessorkern mit 64 MB integriertem Hochgeschwindigkeits-SDRAM, bewältigt diese CPU die gleichzeitige Aufgabenverwaltung mit vorhersehbaren Ausführungsmustern. Die Hardware bietet eine umfassende Netzwerkstruktur mit einer RS232-Schnittstelle für ältere serielle Verbindungen, einem Standard-Ethernet-Port für die Integration ins Firmennetzwerk, zwei USB-Anschlüssen für lokale Systemverwaltung und einer X2X Link-Bus-Master-Schnittstelle zur lokalen I\/O-Erweiterung. Zusätzlich verfügt das Gerät über eine integrierte Echtzeit-Ethernet-POWERLINK-Verbindung (V1\/V2), die eine hochpräzise Synchronisation von entfernten Antrieben und verteilten I\/O-Blöcken ermöglicht. Die Systemüberwachung erfolgt über lokale Statusanzeigen, die sofortige Diagnosen zu CPU-Funktion, Übertemperaturzustand, Ethernet-Verbindung, POWERLINK-Status, CompactFlash-Zugriff und Backup-Batterieladung liefern.\u003c\/p\u003e\n\u003ch3\u003eUmfassende technische Spezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSystemparameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Werte\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20CP1484-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduktkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmbedded-CPU-Modul\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProzessorarchitektur\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCeleron 266 kompatibel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystemspeicher (RAM)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 MB SDRAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrierte Kommunikationsschnittstellen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x RS232, 1x Ethernet, 1x POWERLINK V1\/V2, 2x USB, 1x X2X Link\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKühlmethode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLüfterlose Konvektionskühlung\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEingangsspannung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (-15 % \/ +20 % Toleranz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximaler Eingangsstrom\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,2 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBemessete Bus-Ausgangsspannung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZulässige Schaltbelastung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTypische Leistungsaufnahme\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpeichermedium-Unterstützung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompactFlash-Kartenslot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAbmessungen (B x H x T)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 x 99 x 85 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetto-Gerätegewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,7 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBruttoversandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,0 kg (inklusive robuster Transportverpackung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnische Diagnostik FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWas ist zu tun, wenn die Übertemperatur-LED rot leuchtet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEin aktives Übertemperatur-Signal zeigt an, dass die interne CPU-Temperatur die sicheren Betriebsgrenzen überschritten hat. Überprüfen Sie umgehend, ob die Belüftungskanäle des Schaltschranks frei sind, stellen Sie sicher, dass die lüfterlosen Kühlrippen staubfrei sind, und vergewissern Sie sich, dass benachbarte Hardware die thermischen Strahlungsrichtlinien nicht überschreitet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie werden das Echtzeitbetriebssystem und das Anwendungsprogramm auf diesem Modul gespeichert?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer X20CP1484-1 verwendet einen dedizierten CompactFlash-Kartenslot für den Systemstart. Das Automation Runtime Betriebssystem, die Konfigurationsparameter und die kompilierten Anwendungsprogramme werden direkt auf der Karte gespeichert, was einen schnellen Controller-Austausch ohne separaten Laptop-Download ermöglicht.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann die X2X Link-Schnittstelle entfernte I\/O-Knoten direkt mit Strom versorgen?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie integrierte X2X Link-Schnittstelle fungiert als Bus-Master und stellt die Signalübertragung sicher. Während sie den Datenfluss steuert, benötigen entfernte I\/O-Knoten, die weiter entlang der Schiene oder über größere Entfernungen liegen, separate X20-System-Stromversorgungsmodule, um Spannungsabfälle in der Busleitung auszugleichen.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFeldinbetriebnahme- und Einsatzrichtlinien\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware- und Programm-Backup-Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBevor Sie Live-Inbetriebnahmeroutinen über B\u0026amp;R Automation Studio ausführen, legen Sie eine industrielle CompactFlash-Karte mit der korrekten Automation Runtime-Partition ein. Bewahren Sie eine identische Backup-Karte im Steuergehäuse auf, um im Falle eines unerwarteten lokalen Speicherhardware-Ausfalls eine sofortige Wiederherstellung zu ermöglichen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSicherheitsgrenzen der Stromverteilung:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSchließen Sie die eingehende 24 VDC-Versorgung über ein dediziertes, gefiltertes industrielles Stromversorgungsnetz an. Da die CPU während Spitzenverarbeitungs- und Bus-Startzyklen bis zu 2,2 A ziehen kann, verwenden Sie entsprechend dimensionierte Leiter und platzieren Sie eine schnell auslösende Sicherung stromaufwärts, um die interne Elektronik vor Spannungsspitzen zu schützen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eÜberprüfung der Erdung und mechanischen Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMontieren Sie das CPU-Modul fest auf der DIN-Schiene und stellen Sie sicher, dass alle Erdungsklammern eine niederohmige Verbindung zur geerdeten Metallrückwand herstellen. Ziehen Sie alle Kommunikationskabel und Schirmabschlüsse fest, um das Risiko von hochfrequenten elektrischen Störungen im Hochgeschwindigkeits-POWERLINK-Kreis zu minimieren.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086371447147,"sku":"X20CP1484-1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20cp1484-1-mdouc3o5gfc.png?v=1776138162"},{"product_id":"b-r-x20do4322-x20-system-4-channel-digital-output-module","title":"B\u0026R X20DO4322 X20 System 4-Kanal Digital-Ausgangsmodul","description":"\u003ch3\u003eTechnische Beschreibung und Anwendung\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DO4322 (X20DO4322)\u003c\/strong\u003e ist ein industrietaugliches 4-Kanal-Digitalausgangsmodul, das für die hochdichte B\u0026amp;R X20 System-Automatisierungsplattform entwickelt wurde. Es wurde für eine zuverlässige Signalübertragung in automatisierten Verpackungsanlagen, der Steuerung von Schwerlastmaschinen und kontinuierlichen Prozessindustrien konzipiert und regelt die Schaltzustände diskreter Feldaktuatoren. Das Modul eignet sich hervorragend zum Ansteuern von niederleistungsinduktiven, ohmschen und kapazitiven Lasten wie Magnetventilen, Hilfsrelais und Statusanzeigen. Mit seinem ultrakompakten Formfaktor optimiert das Modul den Platz im Schaltschrank und bietet gleichzeitig schnelle Verarbeitungsgeschwindigkeiten. Die Integration der Einheit in Ihren lokalen oder entfernten I\/O-Knoten gewährleistet eine latenzarme Steuerungsschleifen-Ausführung, reduziert Kommunikationszykluszeiten drastisch und schützt nachgelagerte Hardware vor unkontrollierten elektrischen Anomalien.\u003c\/p\u003e\n\u003ch3\u003eBetriebsarchitektur und elektrische Logik\u003c\/h3\u003e\n\u003cp\u003eDiese I\/O-Komponente integriert vier diskrete Digitalausgänge, die für die Steuerung standardmäßiger 24 VDC Industrie-Feldgeräte ausgelegt sind. Die Stromverteilung wird effizient über den zugrundeliegenden X20-Klemmenblock-Bus verwaltet, wodurch die Wärmeabgabe selbst bei gleichzeitigen Mehrkanalschaltvorgängen minimiert wird. Das Modul ist mit internen Diagnosefunktionen ausgestattet, die die Steuerungsinfrastruktur vor Kurzschlusszuständen und thermischen Überlastungen schützen. Die integrierten elektronischen Ausgangsstufen verfügen über eine spezielle Unterdrückungslogik, die Spannungsspitzen absorbiert, die beim Abschalten induktiver Lasten entstehen. Diese Konstruktion eliminiert die Notwendigkeit externer Freilaufdioden und gewährleistet einen stabilen Busbetrieb während intensiver Hochfrequenz-Schaltzyklen.\u003c\/p\u003e\n\u003ch3\u003eFunktionale Leistungskennzahlen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eBetriebsparameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20DO4322\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Digitalausgang\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnzahl der Kanäle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Ausgänge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNenn-Betriebsspannung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAusgangstyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHalbleiter (Source\/PNP-Schaltung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKurzschlussschutz\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrierte elektronische Strombegrenzung\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eÜberlastschutz\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermische Abschaltmechanismen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolationsbarriere\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptokoppler-Isolation zwischen Bus und I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatusanzeige\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKanalspezifische LED-Betriebsanzeigen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebsfeuchtigkeitsbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLagerfeuchtigkeitsbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetto-Gewicht der Hardware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCa. 0,09 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrutto-Versandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,5 kg (inklusive schützender Exportverpackung)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystemintegrations-FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBenötigt das X20DO4322 eine externe Sicherung für einzelne Ausgänge?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDas Modul verfügt über einen elektronischen Kurzschluss- und Überlastschutz, der den Strom bei einem Fehler automatisch begrenzt. Dennoch wird empfohlen, eine externe schnellwirkende Sicherung in der Haupt-24-VDC-Feldversorgungsleitung zu installieren, um den gängigen industriellen Sicherheitsvorschriften zu entsprechen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWie signalisiert das Modul einen Kanalfehler an die Haupt-SPS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWenn eine Überlast- oder Kurzschlussbedingung einen Kanalausfall auslöst, registriert das Modul ein Fehlerstatusbyte auf dem internen X20-Systembus. Diese Diagnosedaten werden in Echtzeit an Automation Studio übertragen, sodass der Controller präzise lokale Alarmroutinen auslösen kann.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKann dieses Modul Wechselspannungs-Lasten schalten?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNein. Das interne Schaltnetzwerk verwendet DC-Halbleitertransistoren, die ausschließlich für 24 VDC-Quellbetrieb ausgelegt sind. Der Anschluss einer Wechselspannungsquelle zerstört die Ausgangsschaltung.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallationsprotokoll und Wartungsrichtlinien\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnterdrückung induktiver Lasten:\u003c\/strong\u003e Obwohl das Modul interne Schutznetzwerke zur Dämpfung kleiner induktiver Rückschläge enthält, benötigen induktive Komponenten mit hoher Einschaltdauer (wie große 24 VDC-Hydraulikmagnetventile) externe Überspannungsunterdrücker oder Varistoren, die direkt an den Spulenklemmen angebracht werden. Dies maximiert die langfristige Lebensdauer der internen Transistoren.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAusrichtung des Klemmenblocks:\u003c\/strong\u003e Setzen Sie das Modul vertikal in das entsprechende X20-Basismodul ein, bis die Verriegelungsklammern einrasten. Verwenden Sie bei allen 24 VDC-Feldanschlüssen standardisierte Aderendhülsen, um eine sichere Verbindung in den Federklemmen zu gewährleisten und Mikrolichtbögen durch lose Drahtlitzen zu vermeiden.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermische Abminderungsanforderungen:\u003c\/strong\u003e Sorgen Sie für ausreichende Belüftungsabstände rund um die X20-Rackeinheit. Bei Betrieb bei hohen Umgebungstemperaturen bis zur Systemgrenze überprüfen Sie den Gesamtstromverbrauch aller vier Kanäle, um sicherzustellen, dass die thermische Abgabe innerhalb des sicheren Betriebsbereichs bleibt.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086371479915,"sku":"X20DO4322","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20do4322-cdrrzi23y1z.png?v=1776138189"},{"product_id":"b-r-x20di2377-x20-system-2-channel-digital-input-module","title":"B\u0026R X20DI2377 X20 System 2-Kanal Digital-Eingangsmodul","description":"\u003ch3\u003eTechnische Beschreibung und Anwendung\u003c\/h3\u003e\n\u003cp\u003eDas \u003cstrong\u003eX20DI2377 (X20DI2377)\u003c\/strong\u003e ist ein hochpräzises, 2-Kanal-Digital-Eingangsmodul, das für die modulare B\u0026amp;R X20 Systeminfrastruktur entwickelt wurde. Es ist ausgelegt für anspruchsvolle Signalverarbeitung in Verarbeitungsanlagen, hochautomatisierten Montage- und Materialflusssystemen und bietet diskrete Überwachung für 24 VDC Industriessensoren. Es verfügt über eine Sink-Eingangsschaltung, die für 3-Draht-Verbindungen ausgelegt ist und somit externe Verteilungsklemmen überflüssig macht. Ausgestattet mit zwei spezialisierten 50-kHz-Ereigniszählern und einem vollständig konfigurierbaren Eingangsfilter, puffert die Hardware effektiv hochfrequente Impulseingänge von Durchflussmessern oder Näherungssensoren. Die Integration dieses robusten Moduls in Ihr I\/O-Rack gewährleistet eine Signalregistrierung im Mikrosekundenbereich, schützt kritische Automatisierungsprozesse vor elektrischem Jitter und verhindert kostspielige Systemausfälle.\u003c\/p\u003e\n\u003ch3\u003eHardware-Architektur und Funktionslogik\u003c\/h3\u003e\n\u003cp\u003eDas Modul arbeitet nach dem Eingangskennlinien-Standard Typ 1 gemäß EN 61131-2 und liefert eine konsistente Logikzustandserkennung über schwankende Spannungsbereiche von -15 % bis +20 % des nominalen 24 VDC-Basiswerts. Die Einheit verfügt über einen integrierten Kurzschlussschutz, der einen maximalen Spannungsabfall von 2 VDC bei 500 mA bewältigen kann, mit einer strengen Gesamtstrombegrenzung von 0,5 A. Für eine schnelle Felddiagnose zieht die Eingangsschaltung pro Kanal typischerweise 10,5 mA bei 24 VDC, was ein geringes thermisches Profil bei gleichzeitig positiven Schaltschwellen gewährleistet. Die Stromversorgung wird sicher über den Modulbus verwaltet, wobei der maximale Leistungsverbrauch auf 12 W begrenzt ist, um die Integrität benachbarter Module im lokalen Knotenstapel zu erhalten.\u003c\/p\u003e\n\u003ch3\u003eBetriebsleistungs-Spezifikationen\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eKernparameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnische Spezifikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20DI2377\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarke\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulkategorie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Digitaler Eingang\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnzahl der Eingänge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Kanäle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSchaltungstyp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSink (IEC Typ 1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNenn-Eingangsspannung\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eZulässiger Eingangsspannungsbereich\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,4 bis 28,8 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTypischer Eingangsstrom\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,5 mA bei 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpezialfunktionen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2x Ereigniszähler (max. 50 kHz Frequenz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVerdrahtungskonfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Draht-Anschlussdesign\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKurzschlussschutz\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJa (integriert)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximaler Stromverbrauch\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBetriebliche Luftfeuchtigkeit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLager- \/ Transportfeuchtigkeit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 bis 95 % nicht kondensierend\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHerkunftsland\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eÖsterreich\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVersandgewicht\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,0 kg (Bruttogewicht verpackt)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnische FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWie konfiguriere ich die 50-kHz-Ereigniszähler am X20DI2377?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDie Hochgeschwindigkeitszählerfunktionen werden über Automation Studio im Hardware-Konfigurationsbaum zugeordnet. Sie können sie so einstellen, dass sie steigende Flanken, fallende Flanken oder Flankenwechsel an beiden Seiten erfassen, um eine präzise Hochgeschwindigkeits-Impulszählung bis zu 50 kHz zu ermöglichen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersorgt dieses Modul angeschlossene 3-Draht-Sensoren direkt mit Strom?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eJa. Das Moduld esign unterstützt eine direkte 3-Draht-Schnittstelle. Es leitet die interne Modulversorgungsspannung (abzüglich des internen Schutzspannungsabfalls) direkt an die Feldanschlüsse weiter, um externe Näherungsschalter oder Lichtschranken mit Strom zu versorgen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWas passiert, wenn ein Kurzschluss in der Sensorversorgungsleitung auftritt?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDer integrierte Kurzschlussschutz wird sofort aktiviert, wenn der Strombedarf ansteigt, und begrenzt den Summenstrom auf sichere 0,5 A. Das Modul begrenzt Schäden am internen Bus und meldet einen I\/O-Fehlercode an die Steuerung, bis der Feldkurzschluss behoben ist.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInbetriebnahme vor Ort und Sicherheitsprotokolle\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKalibrierung des konfigurierbaren Eingangsfilters:\u003c\/strong\u003e Um die Auswirkungen von mechanischem Kontaktprellen bei Relais oder schweren Schaltern zu minimieren, passen Sie die Zeitkonstante des Software-Eingangsfilters in Ihrer SPS-Umgebung an. Für Hochgeschwindigkeitszählanwendungen bei 50 kHz halten Sie den Filter auf der minimalen Einstellung; für Standard-Näherungsschalter erhöhen Sie die Filterzeit, um hochfrequentes induktives Rauschen zu blockieren.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3-Draht-Klemmenverdrahtung:\u003c\/strong\u003e Schließen Sie die positive Sensorspannung, den Sensorsignal-Masseanschluss und die aktive Signalleitung direkt an die vorgesehenen X20-Klemmenpunkte an. Stellen Sie sicher, dass alle Litzen vollständig in der Federklemme sitzen, um intermittierende Stromunterbrechungen zu vermeiden, die den Kurzschlussschutz auslösen könnten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUmgebungsgehäuseanforderungen:\u003c\/strong\u003e Das X20DI2377 benötigt saubere, trockene Betriebsbedingungen mit einer relativen Luftfeuchtigkeit strikt zwischen 5 und 95 % (nicht kondensierend). Installieren Sie die komplette X20-Rackeinheit in einem Industriegehäuse mit Schutzart IP54, um Risiken durch leitfähigen Staub und ölhaltigen Nebel, wie sie auf Fabrikböden üblich sind, zu minimieren.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086371578219,"sku":"X20DI2377","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20di2377-1bwpx4wynv2.png?v=1776138181"}],"url":"https:\/\/www.plcprotech.com\/de\/collections\/b-r-x20-system.oembed?page=4","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}