{"product_id":"abb-200-bpn-492897301-sattcon-200-central-system-backplane","title":"ABB 200-BPN 492897301 SattCon 200 Central System Backplane","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for industrial processing environments, the ABB 200-BPN (part number 492897301) functions as the physical and electrical backbone for the SattCon 200 and Advant S200 central system units. This backplane provides \u003cstrong\u003etwo dedicated slots\u003c\/strong\u003e equipped with snap locks to secure central processors and system modules firmly in place. Designed with integrated safety mechanisms and dual-mounting versatility, the \u003cstrong\u003eABB 200-BPN\u003c\/strong\u003e ensures high-integrity bus communication and mechanical stability in demanding control configurations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDual-slot architecture supporting up to two central system units.\u003c\/li\u003e\n  \u003cli\u003eRobust dual snap-lock mechanisms for secure unit retention under operational stress.\u003c\/li\u003e\n  \u003cli\u003eDual 8-position rotary mechanical coding keys to prevent mismatching during module insertion.\u003c\/li\u003e\n  \u003cli\u003eFlexible mounting options supporting standard DIN-rail installation or direct surface screw mounting.\u003c\/li\u003e\n  \u003cli\u003eSupport for up to four 200-BPP screw terminal blocks (two allocated per slot).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eSattCon 200 control system architectures.\u003c\/li\u003e\n  \u003cli\u003eAdvant Controller 250 (AC250) processing nodes.\u003c\/li\u003e\n  \u003cli\u003eHeavy mechanical stress environments requiring auxiliary screw-secured backplanes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e200-BPN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e492897301\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSystem Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAdvant S200 I\/O \/ SattCon 200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNumber of Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCoding Keys\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 x 8-position mechanical rotary keys\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTerminal Block Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMaximum 4 x 200-BPP screw terminal blocks\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMounting Options\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e35mm DIN-rail or Panel surface mount via screw holes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePhase-Out (Classic\/Legacy)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e25.0 cm x 12.0 cm x 10.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.27 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eECCN Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eInterface Slot \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSlot 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCentral System Unit 1 primary bus interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSlot 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCentral System Unit 2 secondary\/redundant bus interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTerminal Block Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eInterfaces for up to 4 x 200-BPP screw terminal blocks (2 per Central System slot)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 200-BPN is specifically engineered for central processors and communication interfaces. It should not be confused with standard I\/O terminal bases like the 200-TB3 or 200-TBN, which are reserved for standard Advant S200 I\/O modules. When retrofitting legacy SattCon 200 setups or upgrading to the Advant Controller 250 platform, verify that your processing units match the form factor governed by the 200-BPN's mechanical physical dimensions.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIn environments characterized by continuous low-frequency vibrations, relying solely on the built-in DIN-rail tension clip can lead to micro-intermittency on the backplane data bus. In such applications, utilizing the dedicated supplementary chassis mounting screw is necessary to maintain physical alignment and avoid bus faults.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways configure and verify the position of the dual 8-position mechanical coding keys prior to module insertion. Forcing a mismatching processor unit into the slot will snap the coding pins or damage the delicate male\/female bus connector pins, requiring complete replacement of the backplane.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all power sources connected to the backplane, terminal blocks, and associated central system modules prior to physical installation, mounting, or removal. Failure to comply can result in destructive electrical arcing, module failure, or personal injury.\n\u003c\/div\u003e\n\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli style=\"display: flex; margin-bottom: 1rem; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; min-height: 28px; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eMount the 200-BPN backplane onto a clean, grounded 35mm DIN rail. If installing in severe mechanical stress conditions, secure the backplane using the supplementary screw hole directly to the subpanel.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; margin-bottom: 1rem; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; min-height: 28px; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eAlign and set the mechanical rotary code keys on the backplane to match the target central system modules.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; margin-bottom: 1rem; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; min-height: 28px; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eCarefully guide the central system units into the designated slots until the dual snap locks click securely into place.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; margin-bottom: 1rem; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; min-height: 28px; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eInstall the 200-BPP screw terminal blocks (maximum 2 blocks per slot) and terminate external wiring following standard ESD precautions.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701956112747,"sku":"200-BPN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/200-bpn-kf1yxgae3ij_efae396e-ba05-4886-8db1-e80fe0bacc9f.jpg?v=1766478080","url":"https:\/\/www.plcprotech.com\/de\/products\/abb-200-bpn-492897301-sattcon-200-central-system-backplane","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}