{"product_id":"abb-3bse013064r1-pu516-advant-ocs-pu516-engineering-board-pci","title":"ABB 3BSE013064R1 PU516 Advant OCS PU516 Engineering Board -PCI","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3BSE013064R1\u003c\/strong\u003e is an industrial PC-based interface board developed by ABB to function as an engineering communication node within the Advant OCS architecture. Operating under the type designation \u003cstrong\u003ePU516\u003c\/strong\u003e, this board bridges system configurations by establishing critical link capabilities directly through a standard 5V, 32-bit, 33MHz PCI bus slot. The \u003cstrong\u003e3BSE013064R1\u003c\/strong\u003e is configured with an integrated hardware interface consisting of one MB300 communication port and one RS-232 serial port, enabling simultaneous high-speed peer-to-peer subsystem linking and localized serial maintenance diagnostics. Equipped with 16 megabytes of onboard memory, the \u003cstrong\u003ePU516\u003c\/strong\u003e processor card offloads deterministic data traffic from the host platform, ensuring the stable synchronization required for engineering stations, control networks, and Master software configurations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt with 16Mbyte of dedicated onboard memory for real-time buffering and data throughput.\u003c\/li\u003e\n\u003cli\u003eFeatures dual-interface connectivity providing one MB300 port and one RS-232 port.\u003c\/li\u003e\n\u003cli\u003eDesigned to interface with standard 5V, 32-bit, 33MHz PCI bus architectures.\u003c\/li\u003e\n\u003cli\u003eFacilitates specialized station link integration within Advant OCS with Master SW platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdvant Station 100 Engineering Board systems utilizing PCI-based communication modules.\u003c\/li\u003e\n\u003cli\u003eDistributed Control Systems (DCS) requiring localized RS-232 engineering access and MB300 data tracking.\u003c\/li\u003e\n\u003cli\u003eIndustrial workstation expansions executing real-time control logic orchestration and programming updates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE013064R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePU516\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePU516 Engineering Board -PCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI bus (5V, 32-bit, 33MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16Mbyte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x MB300 network port, 1 x RS-232 serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSweden (SE) \/ Germany (DE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExchange Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXC3BSE013064R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Port\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMB300 Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnects to the MasterBus 300 control network for real-time process data exchange.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS-232 Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnects to standard serial diagnostic terminals or localized configuration tools.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCI Edge Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEstablishes electrical and logical contact with the host 5V 32-bit PCI motherboard slot.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003ePCI Slot Placement\u003c\/h3\u003e\n\u003cp\u003eTurn off all primary power sources supplying the engineering station or host enclosure before opening the assembly. Put on a calibrated anti-static wrist strap connected to a verified ground point. Insert the \u003cstrong\u003ePU516\u003c\/strong\u003e board straight down into the designated 5V 32-bit PCI slot until the edge connector makes full contact with the bus terminal, then secure the metal bracket screw.\u003c\/p\u003e\n\u003ch3\u003eShielding and Interference Protection\u003c\/h3\u003e\n\u003cp\u003eUse fully shielded cabling for both the MB300 and the RS-232 communication lines. Ground the cable shields explicitly at the designated enclosure entry point to prevent environmental electrical noise from corrupting data registers or disrupting the underlying real-time PCI bus communication timings.\u003c\/p\u003e\n\u003ch3\u003eThermal Management\u003c\/h3\u003e\n\u003cp\u003eVerify that internal cabinet ventilation routing matches factory specifications. Leave clear airway paths around the \u003cstrong\u003e3BSE013064R1\u003c\/strong\u003e board to prevent localized thermal pockets from affecting the performance of the onboard memory modules and communication transceivers.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668629582187,"sku":"PU516 3BSE013064R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-pu516-3bse013064r1-engineering-board-spj1z0c4skn_33161af6-e5e9-4742-b670-c8ca399d7dee.jpg?v=1765536113","url":"https:\/\/www.plcprotech.com\/de\/products\/abb-3bse013064r1-pu516-advant-ocs-pu516-engineering-board-pci","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}