{"product_id":"abb-rdco-02c-ddcs-communication-option-module","title":"ABB RDCO-02C DDCS Communication Option Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRDCO-02C\u003c\/strong\u003e is an add-on communication option module designed to handle high-speed data transmission and fieldbus networking within variable speed drive configurations. This module functions as an industrial interface board that establishes \u003cstrong\u003eDDCS communication\u003c\/strong\u003e channels for the RMIO Motor Control and I\/O board or BCU control units. Operating as a bridge for fiber optic connections, the board contains four discrete optical channels (CH0, CH1, CH2, and CH3) used to network overriding systems, local peripheral options, master-follower drive links, and diagnostic PC tools. Equipped with a coated circuit board to ensure protection against environmental degradation , the \u003cstrong\u003eRDCO-02C\u003c\/strong\u003e provides deterministic signaling and robust noise immunity essential for reliable automated operations in demanding industrial sectors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete fiber optic communication interface with four integrated transmitter\/receiver connector pairs \u003c\/li\u003e\n\u003cli\u003eFeatures a coated circuit board (indicated by the C suffix) to provide enhanced protection in standard industrial applications \u003c\/li\u003e\n\u003cli\u003eDirect electrical integration through a built-in 20-pin pinheader that connects power and signal directly to the drive control unit \u003c\/li\u003e\n\u003cli\u003eFlexible media capability supporting plastic optical fiber (POF) and Hard Clad Silica (HCS) physical lines \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed master-follower variable speed drive coordination links \u003c\/li\u003e\n\u003cli\u003eOverriding system fieldbus adapter interfacing and data communication bridging \u003c\/li\u003e\n\u003cli\u003eDrive parameter monitoring and external I\/O configuration expansion networks \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRDCO-02C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDCS Communication Option Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel CH0 Optical Component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 MBd \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel CH1 Optical Component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 MBd \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel CH2 Optical Component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MBd \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel CH3 Optical Component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MBd \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Communication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 2 or 4 Mbit\/s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20-pin pinheader \/ Agilent Technologies Versatile Link pairs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 V DC ±10% (supplied by drive control unit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA max. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP 20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm x 95 mm x 34 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rules:\u003c\/strong\u003e Ensure all mains input voltages and external dangerous voltages from control circuits are fully isolated and locked out before initiating work on the system. Always wait 5 minutes for the intermediate circuit capacitors to completely discharge after cutting power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Prevention:\u003c\/strong\u003e The internal board assemblies carry micro-circuits highly susceptible to electrostatic breakdown. Personnel must wear an earthing wrist band when handling the equipment and avoid touching component traces unnecessarily.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Alignment:\u003c\/strong\u003e Insert the module safely into the designated slot marked with \"DDCS\" until the plastic clips engage into position. Fasten the two supplied M3x8 screws securely; these provide the structural earth path and interconnect module and board grounds to fulfill local EMC requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Handling:\u003c\/strong\u003e Do not touch the fiber optic endpoints with bare hands since the interfaces are sensitive to surface dirt. Verify that cable long-term tensile loads remain below 1 N and respect a minimum short-term bend radius of 35 mm.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668514468203,"sku":"RDCO-02C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-rdco-02c-communication-adapter-srrgkhmqz1n_ca7dd0dd-855a-4af7-905b-288bb9fb02a1.jpg?v=1765532625","url":"https:\/\/www.plcprotech.com\/de\/products\/abb-rdco-02c-ddcs-communication-option-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}