{"product_id":"abb-rusb-02-3aua0000040000-drivewindow-2-x-pc-card-kit-en","title":"ABB RUSB-02 3AUA0000040000 DriveWindow 2.x PC Card kit (EN)","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDriveWindow 2.x EN\u003c\/strong\u003e is a Windows-based industrial software application platform engineered for the commissioning, startup, and operational maintenance of high-performance ABB variable frequency drives and converter systems. This \u003cstrong\u003e3AUA0000040000\u003c\/strong\u003e deployment kit contains the \u003cstrong\u003eRUSB-02\u003c\/strong\u003e optical connection adapter package, facilitating a deterministic point-to-point or broadcast communication architecture via high-speed fiber optic networks directly to the drive’s DDCS tracking boards. By deploying this software, technical operations specialists can continuously monitor real-time drive operations, carry out online or offline control parameter scaling, capture high-speed dynamic trend curves, and perform complete fault diagnostic logging extractions. This utility is primarily integrated across synchronous multi-drive processing environments including pulp and paper, metallurgy, marine propulsion, and heavy cranes, providing high-capacity parameter backups and detailed troubleshooting tools without interfering with the underlying safety-critical execution loops of the system hardware.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Optical Link:\u003c\/strong\u003e Utilizes the bundled RUSB-02 interface kit to establish a high-bandwidth, noise-immune DDCS fiber optic communication path with active drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Platform Operating System Support:\u003c\/strong\u003e Validated for stable engineering deployment across Microsoft Windows 2000, Windows XP, Windows Vista, Windows 7 (32-bit and 64-bit), and Windows 8 (32-bit and 64-bit) systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Signal Trend Capture:\u003c\/strong\u003e Features an integrated high-speed monitoring trace tool and graphical oscilloscope functionality to record real-time motor current, torque, and velocity anomalies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulk Parameter Configuration Management:\u003c\/strong\u003e Enables single-button uploads and downloads of complete parameter manifests to facilitate rapid configuration cloning and speed up hardware panel replacement procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Speed Distributed Group Drive Monitoring and Real-Time Calibration in Metallurgy and Paper Production Lines\u003c\/li\u003e\n\u003cli\u003eOffline Parameter Optimization, Verification, and Version Control Management for Large-Scale DC\/AC Industrial Power Converters\u003c\/li\u003e\n\u003cli\u003ePredictive Maintenance Diagnostics and Dynamic Fault Waveform Data Extraction from Distributed System Drive Cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eQty\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eUnit\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3AUA0000040000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDriveWindow 2.x (Win2000, XP, Vista, Win7\/32 and 64-bit, Win8\/32 and 64-bit), incl. RUSB-02 connecti\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003epiece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e61046534\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFIBRE OPTIC CABLE\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003epiece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3AUA0000040000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDriveWindow 2.x EN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 mm (0.866 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 mm (1.024 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 mm (1.417 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.579 kg (1.276 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Level 1 Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecarton 1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number \/ HS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Not in WEEE Scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRUSB-02 Adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConverts standard host computer USB port communication into physical DDCS fiber optic data streams for drive module interfacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e61046534 Fibre Optic Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-transmittance optical fiber link providing high-voltage galvanic isolation and data path routing between the PC and drive controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating System Compliance Audit:\u003c\/strong\u003e Verify that the designated engineering workstation is running an approved version of Microsoft Windows (ranging from Windows 2000 through Windows 8 in either 32-bit or 64-bit architecture) before starting application setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Interfacing Connection Sequence:\u003c\/strong\u003e Run and complete the DriveWindow 2.x setup program on the host PC prior to inserting the physical RUSB-02 module into the USB interface to ensure communication drivers register properly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Routing Bend Radius Management:\u003c\/strong\u003e When running the 61046534 fiber optic cable, strictly observe the minimum bending radius limits outlined in the manual to eliminate internal signal attenuation or packet loss risks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDDCS Channel Node Mapping:\u003c\/strong\u003e Before triggering multi-point broadcast scanning, verify that the individual DDCS station IDs on the drive communication interfaces (such as RDCO or SDCS-COM boards) correspond precisely with the software path settings.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668498674027,"sku":"RUSB-02 3AUA0000040000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-rusb-02-3aua0000040000-field-kit-0gefbsaivu1_69bccdc1-41ec-466e-8fc5-bec3c017c56b.jpg?v=1765532494","url":"https:\/\/www.plcprotech.com\/de\/products\/abb-rusb-02-3aua0000040000-drivewindow-2-x-pc-card-kit-en","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}